Sunteți pe pagina 1din 8

J Thermocouple Data

Temp to Volts
-210C
to
760C
760
0.0000000000E+00
5.0381187815E+01
3.0475836930E-02
-8.5681065720E-05
1.3228195295E-07
-1.7052958337E-10
2.0948090697E-13
-1.2538395336E-16
1.5631725697E-20

C0
C1
c2
c3
c4
c5
c6
c7
c8

760C
to
1200C
1200
2.9645625681E+05
-1.4976127786E+03
3.1787103924E+00
-3.1847686701E-03
1.5720819004E-06
-3.0691369056E-10
0.0000000000E+00
0.0000000000E+00
0.0000000000E+00

Volts to Temp
-210
to
0C

Temp Range

-8095
to
0uV
0
0.0000000000E+00
1.9528268000E-02
-1.2286185000E-06
-1.0752178000E-09
-5.9086933000E-13
-1.7256713000E-16
-2.8131513000E-20
-2.3963370000E-24
-8.3823321000E-29

Volt Range
c0
c1
c2
c3
c4
c5
c6
c7
c8

ADC Vref
ADC Resolution (bits)
Op-Amp Gain
Fixed Point Multiplier
Data Table Size
Input Offset Voltage
Calculator
Temperature (F)
2000
; Data Table
JTABLE
dt 189,
dt 162,
dt 079,
dt 012,
dt 048,
dt 107,
dt 163,
dt 220,
dt 020,
dt 077,
dt 133,
dt 190,

5
8
100
1
256
1

103,
150,
070,
005,
056,
114,
170,
227,
027,
084,
140,
197,

0
to
42919uV
0.042919
0.0000000000E+00
1.9784250000E-02
-2.0012040000E-07
1.0369690000E-11
-2.5496870000E-16
3.5851530000E-21
-5.3442850000E-26
5.0998900000E-31
0.0000000000E+00

This parameter is the reference voltage used by the ADC


This parameter determines how large of a data table to build
This parameter determines what the thermocouple voltage is for each ADC reading
This parameter specifies what the results are multiplied by before they go into the
This parameter is the number of bytes the final table will be
This parameter specifies how much the multiplied thermocouple voltage is offset b

Temperature (C)
#VALUE!

142,
156,
075,
009,
052,
110,
167,
223,
024,
080,
137,
193,

0
to
760

071,
144,
066,
001,
059,
117,
174,
230,
031,
087,
144,
200,

044,
138,
062,
003,
063,
121,
178,
234,
034,
091,
147,
204,

Thermocouple Voltage
#VALUE!

022,
133,
057,
007,
067,
124,
181,
237,
038,
094,
151,
207,

003,
127,
053,
011,
070,
128,
185,
241,
041,
098,
154,
211,

243,
122,
049,
015,
074,
132,
188,
244,
045,
101,
158,
214,

230,
117,
045,
018,
078,
135,
192,
248,
048,
105,
161,
218,

218,
112,
041,
022,
081,
139,
195,
251,
052,
108,
165,
221,

208,
107,
037,
026,
085,
142,
199,
255,
055,
112,
169,
225,

Voltage at the ADC


#VALUE!

198,
102,
032,
030,
089,
146,
202,
002,
059,
115,
172,
228,

190,
098,
028,
033,
092,
149,
206,
006,
062,
119,
176,
232,

182,
093,
024,
037,
096,
153,
209,
009,
066,
123,
179,
235,

175,
088,
020,
041,
099,
156,
213,
013,
069,
126,
183,
239,

168
084
016
045
103
160
216
017
073
130
186
242

; Data Table
JTABLE
dt 189,
dt 162,
dt 079,
dt 012,
dt 048,
dt 107,
dt 163,
dt 220,
dt 020,
dt 077,
dt 133,
dt 190,
dt 246,
dt 045,
dt 099,
dt 151,

142,
156,
075,
009,
052,
110,
167,
223,
024,
080,
137,
193,
249,
049,
102,
155,

103,
150,
070,
005,
056,
114,
170,
227,
027,
084,
140,
197,
253,
052,
106,
158,

071,
144,
066,
001,
059,
117,
174,
230,
031,
087,
144,
200,
000,
055,
109,
161,

044,
138,
062,
003,
063,
121,
178,
234,
034,
091,
147,
204,
004,
059,
112,
164,

022,
133,
057,
007,
067,
124,
181,
237,
038,
094,
151,
207,
007,
062,
116,
167,

003,
127,
053,
011,
070,
128,
185,
241,
041,
098,
154,
211,
011,
066,
119,
170,

; Data below the zero index offset is negative.


; Pivots must be subtracted below this index
zero_index equ 052
; Pivot List
PIVOT_TABLE
dt 007 123 195

243,
122,
049,
015,
074,
132,
188,
244,
045,
101,
158,
214,
014,
069,
122,
174,

230,
117,
045,
018,
078,
135,
192,
248,
048,
105,
161,
218,
018,
072,
125,
177,

218,
112,
041,
022,
081,
139,
195,
251,
052,
108,
165,
221,
021,
076,
129,
180,

208,
107,
037,
026,
085,
142,
199,
255,
055,
112,
169,
225,
025,
079,
132,
183,

198,
102,
032,
030,
089,
146,
202,
002,
059,
115,
172,
228,
028,
082,
135,
186,

190,
098,
028,
033,
092,
149,
206,
006,
062,
119,
176,
232,
031,
086,
138,
189,

182,
093,
024,
037,
096,
153,
209,
009,
066,
123,
179,
235,
035,
089,
142,
193,

175,
088,
020,
041,
099,
156,
213,
013,
069,
126,
183,
239,
038,
092,
145,
196,

168
084
016
045
103
160
216
017
073
130
186
242
042
096
148
199

760
to
1200
42919
to
69553uV
0.069553
-3.1135818700E+03
3.0054368400E-01
-9.9477323000E-06
1.7027663000E-10
-1.4303346800E-15
4.7388608400E-21
0.0000000000E+00
0.0000000000E+00
0.0000000000E+00

sed by the ADC


data table to build
mocouple voltage is for each ADC reading
are multiplied by before they go into the table
final table will be
ultiplied thermocouple voltage is offset before the ADC

182,
093,
024,
037,
096,
153,
209,
009,
066,
123,
179,
235,

ADC Result
#VALUE!

175,
088,
020,
041,
099,
156,
213,
013,
069,
126,
183,
239,

168
084
016
045
103
160
216
017
073
130
186
242

Make Table

182,
093,
024,
037,
096,
153,
209,
009,
066,
123,
179,
235,
035,
089,
142,
193,

175,
088,
020,
041,
099,
156,
213,
013,
069,
126,
183,
239,
038,
092,
145,
196,

168
084
016
045
103
160
216
017
073
130
186
242
042
096
148
199

K Thermocouple Data

Temp to Volts
0
0.0000000000E+00
3.9450128025E+01
2.3622373598E-02
-3.2858906784E-04
-4.9904828777E-06
-6.7509059173E-08
-5.7410327428E-10
-3.1088872894E-12
-1.0451609365E-14
-1.9889266878E-17
-1.6322697486E-20

C0
C1
c2
c3
c4
c5
c6
c7
c8
c9
c10
a0
a1

1.1859760000E+02
-1.1834320000E-04

Volts to Temp
Temp Range
Volt Range
Range Points
c0
c1
c2
c3
c4
c5
c6
c7
c8
c9
ADC Vref
ADC Resolution (bits)
Op-Amp Gain
Fixed Point Multiplier
Data Table Size
Input Offset Voltage
Calculator
Temperature (F)
110

; Data Table
KTABLE
dt 000,
dt 129,
dt 247,
dt 126,
dt 005,
dt 123,
dt 233,
dt 080,
dt 230,
dt 126,
dt 061,
dt 060,
dt 152,
dt 118,
dt 004,
dt 126,

1372
-1.7600413686E+01
3.8921204975E+01
1.8558770032E-02
-9.9457592874E-05
3.1840945719E-07
-5.6072844889E-10
5.6075059059E-13
-3.2020720003E-16
9.7151147152E-20
-1.2104721275E-23

-200 to 0C
-5,891 to 0V
0
0.0000000000E+00
2.5173462000E-02
-1.1662878000E-06
-1.0833638000E-09
-8.9773540000E-13
-3.7342377000E-16
-8.6632643000E-20
-1.0450598000E-23
-5.1920577000E-28

5
8
120
10
256
0

0 to 500C
0 to 20,644V
0.020644
0.0000000000E+00
2.5083550000E-02
7.8601060000E-08
-2.5031310000E-10
8.3152700000E-14
-1.2280340000E-17
9.8040360000E-22
-4.4130300000E-26
1.0577340000E-30
-1.0527550000E-35

This parameter is the reference voltage used by the ADC


This parameter determines how large of a data table to build
This parameter determines what the thermocouple voltage is for each ADC readin
This parameter specifies what the results are multiplied by before they go into the
This parameter is the number of bytes the final table will be
This parameter specifies how much the multiplied thermocouple voltage is offset b

Temperature (C)
#VALUE!

Thermocouple Voltage
#VALUE!

Voltage at the ADC


#VALUE!

Make Lookup Table


041,
168,
031,
167,
044,
163,
016,
119,
015,
169,
107,
111,
209,
185,
085,
223,

082,
207,
071,
208,
084,
202,
054,
157,
056,
211,
153,
162,
011,
253,
166,
065,

122,
246,
111,
248,
124,
240,
093,
195,
097,
254,
199,
213,
070,
065,
247,
165,

163,
029,
151,
033,
164,
023,
131,
234,
138,
041,
246,
009,
129,
135,
074,
010,

204,
068,
191,
074,
203,
062,
170,
016,
179,
084,
037,
061,
189,
205,
158,
112,

244,
107,
232,
114,
243,
101,
208,
054,
220,
128,
084,
114,
249,
020,
243,
215,

028,
147,
016,
155,
026,
140,
247,
092,
005,
171,
131,
167,
054,
091,
073,
063,

068,
186,
057,
195,
066,
179,
029,
131,
047,
215,
179,
220,
116,
164,
160,
169,

108,
225,
097,
236,
105,
218,
068,
169,
088,
003,
227,
018,
178,
237,
248,
021,

148,
008,
138,
020,
144,
001,
106,
207,
130,
047,
019,
072,
240,
055,
081,
129,

188,
048,
179,
060,
184,
039,
145,
245,
171,
092,
068,
127,
048,
130,
171,
239,

227,
087,
219,
100,
223,
078,
183,
028,
213,
136,
117,
182,
112,
205,
006,
095,

011,
127,
004,
141,
006,
117,
221,
066,
001,
181,
166,
238,
176,
026,
098,
208,

050,
167,
045,
181,
045,
156,
004,
104,
041,
226,
216,
038,
241,
103,
192,
066,

089
207
086
221
084
194
042
190
084
016
010
095
051
181
030
182

; Data Table
KTABLE
dt 000,
dt 129,
dt 247,
dt 126,
dt 005,
dt 123,
dt 233,
dt 080,
dt 230,
dt 126,
dt 061,
dt 060,
dt 152,
dt 118,
dt 004,
dt 126,

041,
168,
031,
167,
044,
163,
016,
119,
015,
169,
107,
111,
209,
185,
085,
223,

082,
207,
071,
208,
084,
202,
054,
157,
056,
211,
153,
162,
011,
253,
166,
065,

122,
246,
111,
248,
124,
240,
093,
195,
097,
254,
199,
213,
070,
065,
247,
165,

163,
029,
151,
033,
164,
023,
131,
234,
138,
041,
246,
009,
129,
135,
074,
010,

204,
068,
191,
074,
203,
062,
170,
016,
179,
084,
037,
061,
189,
205,
158,
112,

244,
107,
232,
114,
243,
101,
208,
054,
220,
128,
084,
114,
249,
020,
243,
215,

028,
147,
016,
155,
026,
140,
247,
092,
005,
171,
131,
167,
054,
091,
073,
063,

068,
186,
057,
195,
066,
179,
029,
131,
047,
215,
179,
220,
116,
164,
160,
169,

108,
225,
097,
236,
105,
218,
068,
169,
088,
003,
227,
018,
178,
237,
248,
021,

148,
008,
138,
020,
144,
001,
106,
207,
130,
047,
019,
072,
240,
055,
081,
129,

188,
048,
179,
060,
184,
039,
145,
245,
171,
092,
068,
127,
048,
130,
171,
239,

227,
087,
219,
100,
223,
078,
183,
028,
213,
136,
117,
182,
112,
205,
006,
095,

011,
127,
004,
141,
006,
117,
221,
066,
001,
181,
166,
238,
176,
026,
098,
208,

050,
167,
045,
181,
045,
156,
004,
104,
041,
226,
216,
038,
241,
103,
192,
066,

089
207
086
221
084
194
042
190
084
016
010
095
051
181
030
182

; Data below the zero index offset is negative.


; Pivots must be subtracted below this index
zero_index equ 000
; Pivot List
PIVOT_TABLE
dt 007 013 020 026 033 039 045 052 058 064 071 077 084 090 097 104 110 117 124 129 135 141 148
153 159 165 170 175 180 185 190 194 199 203 207 211 214 218 221 224 228 231 234 236 239 242 244
247 249 252 254

Column C is good for temperatures less than C3 (0 degrees C)


Column D is good for temperatures less than D3 (1372 degrees C)

500 to 1372 C
20,644 to 54,886V
0.054886
-1.3185800000E+02
4.8302220000E-02
-1.6460310000E-06
5.4647310000E-11
-9.6507150000E-16
8.8021930000E-21
3.1108100000E-26

table to build
ple voltage is for each ADC reading
ultiplied by before they go into the table

ed thermocouple voltage is offset before the ADC

ADC Result
#VALUE!

Make Lookup Table

S-ar putea să vă placă și