Sunteți pe pagina 1din 2

SLUG CATCHER

TECHNICAL
BULLETIN
The scope of the slug catcher is the separation of a The demister space can be divided into multi
two-phase flow. equivalent sections with separate gas outlets and
The two-phase stream flow from the pipeline enters washing devices.
the slug catcher section at about 11.5 m elevation If salt or pipeline solids plug the demisters, it is
from ground. The last part of the pipeline is also possible to wash one section at a time, while the
flanged pieces of pipe slightly sloped downward to other sections continue to work.
permit the liquid to accumulate and be separated. If the amount of liquid phase increases, it is possible
When the flow comes to the separator inlet, the first to add a flanged piece of pipe at the end of the
separation occurs between the gas that flows in the pipeline to accommodate the unexpected flow
separator and the liquids that goes straight to the increase.
end section of the pipeline where it is discharged by To sum up the main features of our proprietary slug
a level control valve. The gas phase flows through catcher are the following:
the separator and the demisters where the remaining • If the liquid flow increases it is possible to handle
entrained liquids are separated to the bottom of the the unexpected liquid stream simply by adding
vessel and returned into the pipeline section (liquid flanged pieces of pipe as needed;
section). • The plugging of the demister will not stop the
Any excess gas retained in the liquid section is operation.
returned to the separator with the equalizer line.
GAS GAS GAS

1 - 1.5

parent company

Tozzi Sud S.p.A.


contacts
World Offices:
Headquarter: Houston USA Web site:
Via Zuccherificio, 10 Caracas VENEZUELA www.tozzisud.com/comart
48010 Mezzano RA – Italy Cairo EGYPT
Tel. +39.0544.525050 Tripoli LYBIA E-mail:
Fax +39.0544.525099 Aksai KAZAKHSTAN comart@tozzisud.com

S-ar putea să vă placă și