Global System for Mobile Communications (GSM)

Nortel GSM BTS


S8000/S8002/S8003/S8006
Fault Clearing
Release: V18.0 PC2
Document Revision: 18.06

www.nortel.com

411-9001-103
.

Global System for Mobile Communications (GSM)


Release: V18.0 PC2
Publication: 411-9001-103
Document release date: 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.
While the information in this document is believed to be accurate and reliable, except as otherwise expressly
agreed to in writing NORTEL PROVIDES THIS DOCUMENT "AS IS" WITHOUT WARRANTY OR CONDITION OF
ANY KIND, EITHER EXPRESS OR IMPLIED. The information and/or products described in this document are
subject to change without notice.

Nortel, Nortel Networks, the Nortel logo, and the Globemark are trademarks of Nortel Networks.
Sourced in Canada, France, and the United States of America.
LEGAL NOTICE
While the information in this document is believed to be accurate and reliable, except as otherwise expressly
agreed to in writing NORTEL PROVIDES THIS DOCUMENT "AS IS" WITHOUT WARRANTY OR CONDITION OF
ANY KIND, EITHER EXPRESS OR IMPLIED. The information and/or products described in this document are
subject to change without notice.
Nortel, the Nortel logo, the Globemark, S2000 and S8000 are trademarks of Nortel Networks.
All other trademarks are the property of their respective owners.
_ 17+ 18+

All other trademarks are the property of their respective owners.

Contents
New in this release
Features

17

17

Introduction

19

Chapter 1 How to use this manual

25

1.1 Introduction 25
1.2 The types of spontaneous messages 26
1.2.1 Events detected by the BTS 26
1.2.2 Events detected by the BSC 26
1.3 Description of a fault number sheet 26
1.3.1 Header of the sheet 26
1.3.2 Main body of the sheet 26
1.4 Help 27
1.4.1 Loading the CD-ROM 27

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault


numbers

29

2.1 Fault number: 1051 (S8000, S8002, S8003, and S8006 BTS) 29
2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS) 29
2.2.1 Source 0: No response to status request 41
2.2.2 Source 1: Bad hardware reference of manufacturer ID 43
2.2.3 Source 2: SUP stop receipt 46
2.2.4 Source 3: No change to one of BOOT states after reset 48
2.2.5 Source 4: This entity is engaged in another downloadingSource 8: Wrong
software reference on a non downloadable TEI 52
2.2.6 Source 5: Software not compatible with hardware 54
2.2.7 Source 6: File access error 58
2.2.8 Source 7: Repetitive errors (NACK, timeout, ...) while downloading a
file 61
2.2.9 Source 9: No response to download message 61
2.2.10 Source 14: Received CSM LOAD CONTAINER NAK 64
2.2.11 Source 15: File to download empty 66
2.2.12 Source 16: File to download unavailable 68
2.2.13 Source 17: Buffer allocation failure 69

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

4
2.2.14 Source 18: Bad sending buffer size value 72
2.2.15 Source 19: Failure during OMU switchover 74
2.2.16 Source 20: Bad TEI sent by BTS in the CSM software update report
message 76
2.2.17 Source 21: CSM software update report with the cause - unknown TEI
- 78
2.2.18 Source 22: CSM software update report with the cause - equipment
failure - 81
2.2.19 Source 23: CSM software update report with the cause - downloading
failure - 83
2.2.20 Source 24: CSM software update report with the cause - not able to
perform- 85
2.2.21 Source 25: CSM software update report with the cause - wrong software
reference - 87
2.2.22 Source 26: CSM software update report with the cause - wrong
configuration reference - 90
2.2.23 Source 27: CSM software update report with the cause - restart request
- 92
2.2.24 Source 28: CSM software update report with the cause - data
inconsistency - 94
2.2.25 Source 29: CSM software update report with the cause - message out of
sequence - 97
2.2.26 Source 30: CSM software update report with the cause - background not
available - 99
2.2.27 Source 31: CSM software update report with the cause - incompatible
RM version - 101
2.2.28 Source 32: CSM software update report with the cause - downloading in
progress - 104
2.2.29 Source 33: Bad report sent by BTS in the CSM software update report
message 106
2.2.30 Source 34: No BTS response on CSM software update init-control
message 108
2.2.31 Source 35: Nack received on the abort requested by operator 111
2.2.32 Source 36: Bad report sent by BTS in the CSM software update abort
message 113
2.2.33 Source 37: No BTS response on CSM software update abort
message 115
2.2.34 Source 38: Flash activate nack with the cause - unknown TEI - 118
2.2.35 Source 39: Flash activate nack with the cause - equipment failure
- 120
2.2.36 Source 40: Flash activate nack with the cause - downloading failure
- 122
2.2.37 Source 41: Flash activate nack with the cause - not able to perform
- 124
2.2.38 Source 42: Flash activate nack with the cause - flash inconsistency
- 127
2.2.39 Source 43: Flash activate nack with the cause - data inconsistency
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

5
- 129
2.2.40 Source 44: Flash activate nack with the cause - wrong soft ref - 131
2.2.41 Source 45: Flash activate nack with the cause - wrong config ref - 133
2.2.42 Source 46: CSM downloading start nack with the cause - unknown TEI
- 136
2.2.43 Source 47: CSM downloading start nack with the cause - equipment
failure - 138
2.2.44 Source 48: CSM downloading start nack with the cause - downloading
failure - 140
2.2.45 Source 49: CSM downloading start nack with the cause - message out
of sequence - 142
2.2.46 Source 50: CSM downloading start nack with the cause - wrong soft ref
- 145
2.2.47 Source 51: CSM downloading start nack with the cause - wrong config
ref - 147
2.2.48 Source 52: CSM downloading start nack with a bad cause 149
2.2.49 Source 53: No BTS response on CSM downloading start message 152
2.2.50 Source 54: CSM downloading end nack with the cause - unknown TEI
- 154
2.2.51 Source 55: CSM downloading end nack with the cause - equipment
failure - 156
2.2.52 Source 56: CSM downloading end nack with the cause - downloading
failure - 158
2.2.53 Source 57: CSM downloading end nack with the cause - value out of
range - 161
2.2.54 Source 58: CSM downloading end nack with a bad cause 163
2.2.55 Source 59: No BTS response on CSM downloading end message 165
2.2.56 Source 60: CSM load init nack with the cause - equipment failure - 168
2.2.57 Source 61: CSM load init nack with the cause - downloading failure
- 170
2.2.58 Source 62: CSM load init nack with the cause - message out of
sequence - 172
2.2.59 Source 63: CSM load init nack with the cause - wrong file ref - 174
2.2.60 Source 64: CSM load init nack with the cause - window size not allowed
- 177
2.2.61 Source 65: CSM load init nack with the cause - data format error - 179
2.2.62 Source 66: CSM load init nack with a bad cause 181
2.2.63 Source 67: No BTS response on CSM load init message 183
2.2.64 Source 68: CSM load data nack with the cause - equipment failure
- 186
2.2.65 Source 69: CSM load data nack with the cause - downloading failure
- 188
2.2.66 Source 70: CSM load data nack with the cause - message out of
sequence - 190
2.2.67 Source 71: CSM load data nack with the cause - data format error
- 192

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

6
2.2.68 Source 72: CSM load data nack with the cause - window overflow
- 195
2.2.69 Source 73: CSM load data nack with the cause - data inconsistency
- 197
2.2.70 Source 74: CSM load data nack with the cause - block not received
- 199
2.2.71 Source 75: CSM load data nack with the cause - bad block tag - 201
2.2.72 Source 76: CSM load data nack with the cause - checksum error - 204
2.2.73 Source 77: CSM load data nack with a bad cause 206
2.2.74 Source 78: Unexpected CSM load data ack 208
2.2.75 Source 79: No BTS response on CSM load data message 210
2.2.76 Source 80: CSM load end nack with the cause - equipment failure
- 213
2.2.77 Source 81: CSM load end nack with the cause - downloading failure
- 215
2.2.78 Source 82: CSM load end nack with the cause - value out of range
- 217
2.2.79 Source 83: CSM load end nack with the cause - message out of
sequence - 219
2.2.80 Source 84: CSM load end nack with the cause - data format error
- 222
2.2.81 Source 85: CSM load end nack with the cause - wrong file ref - 224
2.2.82 Source 86: CSM load end nack with the cause - data inconsistency
- 226
2.2.83 Source 87: CSM load end nack with the cause - checksum error - 229
2.2.84 Source 88: CSM load end nack with a bad cause 231
2.2.85 Source 89: No BTS response on CSM load end message 233
2.2.86 Source 90: Bad report sent by BTS during an internal update 235
2.2.87 Source 91: CSM load init nack with the cause - file already open - 238
2.2.88 Source 92: CSM load init nack with the cause - invalid mode - 240
2.2.89 Source 93: CSM load init nack with the cause - file cannot be unloaded
- 242
2.2.90 Source 94: CSM load init nack with the cause - flash flag cannot access
- 244
2.2.91 Source 95: CSM load data nack with the cause - file cannot be unloaded
- 247
2.2.92 Source 96: CSM load data nack with the cause - flash flag cannot
access - 249
2.2.93 Source 97: CSM load data nack with the cause - boot cannot be
unloaded - 251
2.2.94 Source 98: CSM load data nack with the cause - data decode error
- 254
2.2.95 Source 99: CSM load data nack with the cause - table cannot access
- 256
2.2.96 Source 100: CSM load data nack with the cause - RAM mapping error
- 258

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

7
2.2.97 Source 101: CSM load data nack with the cause - flash access error
- 260
2.2.98 Source 102: CSM load data nack with the cause - flash RAM error
- 263
2.2.99 Source 103: CSM load data nack with the cause - flash erase error
- 265
2.2.100 Source 104: CSM load data nack with the cause - internal abort - 267
2.2.101 Source 105: CSM flash activate response with a bad cause 269
2.2.102 Source 106: DTM error during token allocation 272
2.2.103 Source 107: CSM software update report with the cause: TRX software
incompatibility 274
2.2.104 Source 108: Too many different deliveries in the cell group 276
2.3 Fault number: 1053 (S8000, S8002, S8003, and S8006 BTS) 278
2.4 Fault number: 1054 (S8000, S8002, S8003, and S8006 BTS) 280
2.5 Fault number: 1055 (S8000, S8002, S8003, and S8006 BTS) 280
2.5.1 Source 1: Equipment failure 284
2.5.2 Source 2: Equipment unable to perform such test 285
2.5.3 Source 3: Equipment unable to perform such configuration 286
2.5.4 Source 4: Unknown test 288
2.5.5 Source 5: Cell parameters inconsistency 288
2.5.6 Source 6: Data inconsistency 290
2.5.7 Source 7: Value out of range 291
2.5.8 Source 8: TEI not present 292
2.5.9 Source 9: Unknown Abis PCM_Time_Slot 293
2.5.10 Source 10: Unknown Abis PCM 293
2.5.11 Source 11: Wrong software reference 294
2.5.12 Source 12: Further files required 294
2.5.13 Source 13: Failure during activation 295
2.5.14 Source 14: Data format error 295
2.5.15 Source 15: Window overflow 295
2.5.16 Source 16: Normal completion 295
2.5.17 Source 17: Transfer aborted 295
2.5.18 Source 18: Checksum error 296
2.5.19 Source 19: File incomplete 296
2.5.20 Source 20: File already present and correct 296
2.5.21 Source 21: File cannot be downloaded 296
2.5.22 Source 22: Entity engaged in other download 296
2.5.23 Source 23: Too many signaling timeslots 297
2.5.24 Source 24: Too many TEI connections to physical channel 298
2.5.25 Source 25: Out of sequence message 298
2.5.26 Source 26: Incorrect IEI 300
2.5.27 Source 27: Wrong file reference 300
2.5.28 Source 28: Bad cell number 301
2.5.29 Source 29: Bad related TEI 301

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

8
2.5.30 Source 30: Bad timeslot 301
2.5.31 Source 31: Window size not allowed 301
2.5.32 Source 32: Flash boot required 301
2.5.33 Source 33: Wrong config reference 302
2.5.34 Source 34: The BTS has not acknowledged the TX power consign
request 302
2.5.35 Source 35: Downloading aborted 307
2.5.36 Source 36: Files missing 307
2.5.37 Source 37: Buffer overflow 308
2.5.38 Source 38: Block not received 308
2.5.39 Source 39: Downloading restart 308
2.5.40 Source 40: Request not supported 308
2.5.41 Source 41: Downloading failure 308
2.5.42 Source 42: Start-up failure 309
2.5.43 Source 43: Maximum number of joker TS 309
2.5.44 Source 44: Bad chain type 312
2.5.45 Source 45: Bad radio timeslot reference 312
2.5.46 Source 46: Bad internal Link EDGE configuration 312
2.5.47 Source 47: Inconsistency mapping 312
2.5.48 Source 48: Inconsistency number of joker DS0 313
2.5.49 Source 49: Invalid mode 313
2.5.50 Source 50: File already open 313
2.5.51 Source 51: File cannot be unloaded 313
2.5.52 Source 52: Boot cannot be unloaded 313
2.5.53 Source 53: Data decode error 314
2.5.54 Source 54: Flash flag cannot access 314
2.5.55 Source 55: Table cannot access 314
2.5.56 Source 56: RAM mapping error 314
2.5.57 Source 57: Flash access error 314
2.5.58 Source 58: Flash write error 315
2.5.59 Source 59: Flash erase error 315
2.5.60 Source 60: Internal abort 315
2.5.61 Source 61: Equipment not able to get external synchronization 315
2.5.62 Source 62: Synchronization in progress 315
2.5.63 Source 63: Dynamic Abis feature not supported 316
2.5.64 Source 64: Inconsistent number of joker DS0 317
2.5.65 Source 65: Exceeded DL joker DS0 pool number 319
2.5.66 Source 255: Non-significant value 321
2.6 Fault number: 1056 (S8000, S8002, S8003, and S8006 BTS) 321
2.6.1 Source 0: Incorrect priority on transceiver 324
2.6.2 Source 1: Incorrect setting of channel on transceiver 324
2.6.3 Source 2: Cell without BCCH TDM 324
2.6.4 Source 3: Radio Time Slot not used 325
2.6.5 Source 4: Wrong value for BSS TEI in T1 mode 325
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

9
2.6.6 Source 5: Cell cfg with cavity and dual band not acceptable 325
2.6.7 Source 6: Missing Site management Abis GSM function 325
2.6.8 Source 7: Missing Abis Signalling management Abis GSM function 325
2.6.9 Source 8: Missing Abis traffic management Abis GSM function 326
2.6.10 Source 9: Missing RfTrans management Abis GSM function 326
2.6.11 Source 10: Missing cell management Abis GSM function 326
2.6.12 Source 11: Missing TDMA management Abis GSM function 326
2.6.13 Source 12: Missing TS management Abis GSM function 327
2.6.14 Source 13: The TDMA exists in RDC but the object was not created.
327
2.6.15 Source 14: Too many EDGE TDMAs (more than 16 per site) configured
327
2.7 Fault number: 1058 (S8000, S8002, S8003, and S8006 BTS) 327
2.8 Fault number: 1059 (S8000, S8002, S8003, and S8006 BTS) 328
2.9 Fault number: 1060 (S8000, S8002, S8003, and S8006 BTS) 329
2.9.1 BRC (source: Manual switch on battery power) 351
2.9.2 BRC (source: Automatic switch on battery power) 351
2.9.3 BRC (source: Manual switch on main power) 351
2.9.4 BRC (source: Automatic switch on main power) 352
2.9.5 Cavity (source: Cavity parked after tuning fault (min not found)) 352
2.9.6 Cavity (source: Nack answer from cavity) 354
2.9.7 Cavity (source: Cavity parked after tuning fault (power too low)) 354
2.9.8 Cavity (source: Cavity parked after tuning fault (tuning detector)) 355
2.9.9 CMCF board (source: Unknown message) 355
2.9.10 CMCF board (source: Restart requested by the active board) 356
2.9.11 CMCF (source: Board reset asked by OMC) 356
2.9.12 CMCF board (source: Restart due to hardware watchdog) 357
2.9.13 CMCF boards (source: Restart due to double bus fault) 357
2.9.14 CMCF boards (source: Reset for new Lapd parameters CMCF) 357
2.9.15 CMCF boards (source: ABIS PCM statistics) 358
2.9.16 CSWM board (source: Restart due to hardware watchdog) 358
2.9.17 CSWM board (source: Restart due to double bus fault) 359
2.9.18 DRX or eDRX or DRX-ND3 or eDRX2 modules (source: Frequency
collision on FH bus) 359
2.9.19 DRX or eDRX or DRX-ND3 or eDRX2 (source: Restart requested by
the BCF) 360
2.9.20 DRX or eDRX or DRX ND3 or eDRX2 modules (source: FACCH
congestion) 360
2.9.21 DRX or eDRX or DRX ND3 or eDRX2 modules (source: Reset due to
hardware watchdog) 361
2.9.22 DRX or eDRX or DRX ND3 or eDRX2 modules (source: Restart due to
double bus fault) 362
2.9.23 DRX or eDRX or DRX-ND3 or eDRX2 modules (source: BCCH config
dump) 362
2.9.24 DRX or eDRX or DRX-ND3 modules or eDRX2 (source: SACCH config
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

10
dump) 363
2.9.25 DRX or eDRX or DRX-ND3 or eDRX2 modules (source: L1M config
dump) 363
2.9.26 DRX or eDRX or eDRX2 or DRX-ND3 modules (source: RSL
anomaly) 363
2.9.27 IPM-USER core (source: Restart due to power-on) 364
2.9.28 IPM-USER core (source: Restart due to reset by button) 364
2.9.29 IPM-USER core (source: Restart due to software upgrade) 365
2.9.30 IPM-USER core (source: Restart due to hardware watchdog) 365
2.9.31 IPM-USER core (source: IBOS authentication has failed) 366
2.9.32 IPM-USER core (source: No TCP connection can be set up with
IGM) 366
2.9.33 IPM-USER core (source: Reset requested by IGM with no Ethernet
switch reset) 367
2.9.34 IPM-USER core (source: Reset requested by IGM with Ethernet switch
reset) 367
2.9.35 IPM-USER core (source: Reset requested by IBOS with BIST execution
and Ethernet switch reset) 368
2.9.36 IPM-USER core (source: Reset requested by IBOS with no BIST
execution and Ethernet switch reset) 368
2.9.37 IPM-USER core (source: Reset requested by IBOS with BIST execution
and no Ethernet switch reset) 369
2.9.38 IPM-USER core (source: Reset requested by IBOS with no BIST
execution nor Ethernet switch reset) 370
2.9.39 IPM-USER core (source: Restart after TML commissioning) 370
2.9.40 IPM-USER core (source: Connection with IGM has been lost (no status
received for 7 keep-alive periods)) 371
2.9.41 IPM-USER core (source: No response to DHCP requests for 15
minutes) 371
2.9.42 IPM-USER core (source: No response to DNS requests for 15
minutes) 372
2.9.43 IPM-USER core (source: Debug) 372
2.9.44 IPM-USER core (source: Soft) 373
2.9.45 RIPM-USER core (source: Restart due to power-on) 373
2.9.46 RIPM-USER core (source: Restart due to reset by button) 374
2.9.47 RIPM-USER core (source: Restart due to software upgrade) 374
2.9.48 RIPM-USER core (source: Restart due to hardware watchdog) 375
2.9.49 RIPM-USER core (source: IBOS authentication has failed) 375
2.9.50 RIPM-USER core (source: No TCP connection can be set up with
IGM) 376
2.9.51 RIPM-USER core (source: Reset requested by IGM with no Ethernet
switch reset) 376
2.9.52 RIPM-USER core (source: Reset requested by IGM with Ethernet switch
reset) 377
2.9.53 RIPM-USER core (source: Reset requested by IBOS with BIST
execution and Ethernet switch reset) 377

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

11
2.9.54 RIPM-USER core (source: Reset requested by IBOS with no BIST
execution and Ethernet switch reset) 378
2.9.55 RIPM-USER core (source: Reset requested by IBOS with BIST
execution and no Ethernet switch reset) 378
2.9.56 RIPM-USER core (source: Reset requested by IBOS with no BIST
execution nor Ethernet switch reset) 379
2.9.57 RIPM-USER core (source: Restart after TML commissioning) 379
2.9.58 RIPM-USER core (source: Connection with IGM has been lost (no
status received for 7 keep-alive periods)) 380
2.9.59 RIPM-USER core (source: No response to DHCP requests for 15
minutes) 380
2.9.60 RIPM-USER core (source: No response to DNS requests for 15
minutes) 381
2.9.61 RIPM-USER core (source: Debug) 381
2.9.62 RIPM-USER core (source: Soft) 382
2.9.63 RIPM-USER core (source: Reset requested by active with BIST
execution) 383
2.9.64 RIPM-USER core (source: Reset requested by active with no BIST
execution) 383
2.9.65 Tx Filters (source: VSWR level 2) 384
2.10 Fault number: 1061 (S8000, S8002, S8003, and S8006 BTS) 386
2.11 Attribute value change: 1063 (S8000, S8002, S8003, and S8006 BTS) 386
2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS) 387
2.12.1 ACU climatic unit (source: Cooler fault) 413
2.12.2 ALCO board (source: Major fault) 416
2.12.3 Battery cabinet (source: Over temperature) 419
2.12.4 Battery cabinet (source: DC power fault) 422
2.12.5 Battery cabinet (source: Doors) 425
2.12.6 BCF cabinet door contact(source: BCF cabinet door contact
detection) 429
2.12.7 BCF cabinet fan (source: BCF cabinet fan fault) 433
2.12.8 BCF power supply (source: Volt) 435
2.12.9 BRC (source: Manual switch on battery power) 438
2.12.10 BRC (source: Automatic switch on battery power) 438
2.12.11 BRC (source: Manual switch on main power) 438
2.12.12 BRC (source: Automatic switch on main power) 438
2.12.13 BRC (source: Battery failure) 439
2.12.14 BRC (source: Monitored battery not present) 440
2.12.15 BRC (source: Internal inconsistency) 441
2.12.16 BTS SYNCHRONIZATION (source: SYNO clock not locked on the
network) 441
2.12.17 BTS synchronization (source: Synchro not locked because OCVXO
is KO) 448
2.12.18 BTS synchronization (source: GPS synchronization unavailable) 451
2.12.19 BTS synchronization (source: Loss of GPS synchronization) 456

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

12
2.12.20 BTS SYNCHRONIZATION (source: Lack of GPS synchronization
accuracy) 461
2.12.21 BTS SYNCHRONIZATION (source: Master synchronization
unavailable) 466
2.12.22 BTS SYNCHRONIZATION (source: Loss of master GSM time) 471
2.12.23 BTS SYNCHRONIZATION (source: Loss of master SY) 475
2.12.24 Cabinet door (source: Door contact detection) 479
2.12.25 Cavity (source: Cavity out of service) 483
2.12.26 Cavity (source: Cavity parked after tuning fault (min not found)) 485
2.12.27 Cavity (source: Loss of cavity initialization) 487
2.12.28 Cavity (source: Nack answer from cavity) 489
2.12.29 Cavity (source: Cavity parked after tuning fault (power too low)) 490
2.12.30 Cavity (source: Cavity parked after tuning fault (tuning detector
problem)) 492
2.12.31 Cavity (source: Internal software problem) 494
2.12.32 Cavity combiner (source: Power supply) 496
2.12.33 Cavity combiner (source: Tuning detector fault) 498
2.12.34 Cavity combiner (source: Link NOK) 500
2.12.35 C-DACS climatic system (source: Dirty filter) 502
2.12.36 C-DACS climatic system (source: DACS failed) 504
2.12.37 CMCF board (source: MCF_MCF) 507
2.12.38 CMCF board (source: Slave downloading error) 510
2.12.39 CMCF board (source: CMCF_ACT_DUPLEX_INHIBITED) 512
2.12.40 CMCF board (source: CMCF_ACT_ICST) 515
2.12.41 CMCF board (source: Duplex inhibited: feature not supported on
CMCF phase 1) 517
2.12.42 Combiner duplexer LNA or combiner H2 LNA (source: LNA fault) 520
2.12.43 Combiner duplexer VSWR or combiner H2 VSWR (source: VSWR level
1) 524
2.12.44 Combiner duplexer VSWR or combiner H2 VSWR (source: VSWR level
2) 524
2.12.45 Combiner duplexer VSWR or combiner H2 VSWR (source: VSWR level
3) 525
2.12.46 Combiner H4D LNA (source: LNA fault) 528
2.12.47 Combiner H4D VSWR (source: VSWR level 1) 532
2.12.48 Combiner H4D VSWR (source: VSWR level 2) 534
2.12.49 Combiner H4D VSWR (source: VSWR level 3) 536
2.12.50 Compact distribution system (source: Main breaker) 538
2.12.51 CPCMI board (source: Major) 541
2.12.52 CPCMI board (source: Slave downloading error) 541
2.12.53 CSWM board(source: Fault on active-passive CSWM link or on passive
CSWM) 544
2.12.54 CSWM board (source: Slave downloading error) 547
2.12.55 DACS climatic system (source: Dirty filter) 549
2.12.56 DACS climatic system (source: DACS failed) 551
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

13
2.12.57 Distribution system (source: Main breaker) 557
2.12.58 DRX or DRX-ND3 diversity reception chain (source: Software
detection) 560
2.12.59 DRX or DRX-ND3 main reception chain (source: Software
detection) 565
2.12.60 DRX or DRX-ND3 modules (source: Abis satellite not supported DRX
(ND3)) 569
2.12.61 DRX or DRX-ND3 modules (source: HePA not supported) 570
2.12.62 DRX or DRX-ND3 modules (source: PA configuration exceeded) 573
2.12.63 DRX or eDRX or DRX-ND3 modules (source: BBFILTER ASIC
fault) 576
2.12.64 DRX or eDRX or DRX-ND3 modules (source: The TX has not
acknowledged the power consign request) 580
2.12.65 DRX or eDRX or DRX-ND3 modules (source: RX fault) 585
2.12.66 DRX or eDRX or DRX-ND3 modules (source: L1M first config
failed) 589
2.12.67 DRX or eDRX or DRX-ND3 or eDRX2 modules (source: BCCH first
config failed) 589
2.12.68 DRX or eDRX or DRX-ND3 or eDRX2 modules (source: BCCH second
config failed) 590
2.12.69 DRX or eDRX or DRX-ND3 or eDRX2 modules (source: DRX
link) 591
2.12.70 DRX or eDRX or DRX-ND3 or eDRX2 modules (source: DRX reset by
BSC) 596
2.12.71 DRX or eDRX or DRX-ND3 or eDRX2 modules (source: L1M second
config failed) 597
2.12.72 DRX or eDRX or DRX-ND3 or eDRX2 modules (source: Major fault
on TX) 597
2.12.73 DRX or eDRX or DRX-ND3 or eDRX2 modules (source: Nack
answer) 602
2.12.74 DRX or eDRX or DRX-ND3 or eDRX2 modules (source: PA DRX
control loop fault) 602
2.12.75 DRX or eDRX or DRX-ND3 or eDRX2 modules (source: Post-mortem
dump zone 3) 607
2.12.76 DRX or eDRX or DRX-ND3 or eDRX2 modules (source: SACCH first
config failed) 607
2.12.77 DRX or eDRX or DRX-ND3 or eDRX2 modules (source: SACCH
second config failed) 608
2.12.78 DRX or eDRX or DRX-ND3 or eDRX2 modules (source: Self test
failed) 609
2.12.79 DRX or eDRX or DRX-ND3 or eDRX2 modules (source: TRX not
anymore configured) 613
2.12.80 DSC boards (source: Major fault) 616
2.12.81 DSC boards (source: Channel_HSCX) 618
2.12.82 External alarm (source: Alarm) 621
2.12.83 Fan of the base cabinet (source: Cabinet fan fault) 621

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

14
2.12.84 F-type converters (source: Volt) 624
2.12.85 GTW boards (source: Major fault on GTW) 628
2.12.86 Internal batteries (source: Battery disconnected) 631
2.12.87 IP synchro (source: Unable to lock on IP synchronization) 634
2.12.88 IP synchro (source: Not enough synchronization packets have been
received) 636
2.12.89 IPM-USER commissioning (source: Only one IBOS commissioned at
IPM) 637
2.12.90 IPM-USER commissioning (source: DNS resolution has failed for at
least one IBOS) 638
2.12.91 IPM-USER core (source: IPM BIST failed) 639
2.12.92 IPM-USER core (source: IPM temperature) 640
2.12.93 IPM-USER core (source: DAC unable to lock, synchronization not
possible) 641
2.12.94 Lightning protector (source: Lightning protection fault) 643
2.12.95 Not protected alarm (source: Alarm) 646
2.12.96 Output Rx-splitter D (source: Over current) 646
2.12.97 Output Rx-splitter M (source: Over current) 649
2.12.98 PCM (source: PCM) 652
2.12.99 PCMI boards (source: Major fault on PCMI) 652
2.12.100 Power amplifiers (source: Hardware) 652
2.12.101 Power amplifiers (source: DRX and PA connection) 658
2.12.102 Power amplifiers (source: High temperature ) 663
2.12.103 Power amplifiers (source: High Current ) 667
2.12.104 Power amplifiers (source: PA_PSDW ) 671
2.12.105 Power amplifiers (source: VSWR fault detected by PA) 675
2.12.106 RECAL board (source: Major) 676
2.12.107 RECAL board (source: Slave downloading error) 679
2.12.108 Rectifiers (source: AC fault) 682
2.12.109 Rectifiers (source: DC fault) 686
2.12.110 Rectifiers (source: Over temperature) 688
2.12.111 Rectifiers (source: External battery level 1) 691
2.12.112 Rectifiers (source: PCU protective) 693
2.12.113 Rectifiers (source: Battery on discharges) 697
2.12.114 RIPM-USER core (source: IPM BIST failed) 699
2.12.115 RIPM-USER core (source: IPM temperature) 700
2.12.116 RIPM-USER core (source: DAC unable to lock, synchronization not
possible) 701
2.12.117 RIPM-USER core (source: No link with passive) 703
2.12.118 Rx Filter (source: LNA fault) 704
2.12.119 SYNC boards (source: Major fault on SYNC) 707
2.12.120 Tx Filters (source: VSWR level 2) 709
2.12.121 Tx Filters (source: VSWR level 3) 710
2.13 Fault number: 1070 (S8000, S8002, S8003, and S8006 BTS) 712

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

15
2.14 Fault number: 1073 (S8000, S8002, S8003, and S8006 BTS) 712
2.14.1 Source 9: No response to load message 718
2.14.2 Source 10: Received LOAD INIT NACK 718
2.14.3 Source 11: Received LOAD DATA NACK 718
2.14.4 Source 12: Received LOAD END NACK 718
2.14.5 Source 13: Received LOAD READY NACK 718
2.15 Fault number: 1077 (S8000, S8002, S8003, and S8006 BTS) 719
2.16 Fault number: 1080 (S8000, S8002, S8003, and S8006 BTS) 720
2.17 Fault number: 1165 (S8000, S8002, S8003, and S8006 BTS) 721
2.18 Fault number: 1213 (S8000, S8002, S8003, and S8006 BTS) 721
2.19 Fault number: 1214 (S8000, S8002, S8003, and S8006 BTS) 722
2.20 Fault number: 1258 (S8000, S8002, S8003, and S8006 BTS) 722
2.21 Fault number: 1259 (S8000, S8002, S8003, and S8006 BTS) 724
2.22 Fault number: 1265 (S8000, S8002, S8003, and S8006 BTS) 725
2.23 Fault number: 1266 (S8000, S8002, S8003, and S8006 BTS) 726
2.24 Fault number: 1268 (S8000, S8002, S8003, and S8006 BTS) 727
2.25 Fault number: 1500 (S8000, S8002, S8003, and S8006 BTS) 728
2.26 Fault number: 1505 (S8000, S8002, S8003, and S8006 BTS) 729
2.27 Fault number: 1506 (S8000, S8002, S8003, S8006 BTS) 730
2.28 Fault number: 1508 (S8000, S8002, S8003, S8006 BTS) 731
2.29 Fault number: 30034 (S8000, S8002, S8003, S8006 BTS) 732
2.30 Applicability of the fault numbers to the BTS type 734

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

16

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

17

New in this release


The following section describe what is new in this release for Nortel GSM
BTS S8006 Troubleshooting (411-9001-103) for V18.0 P&C 2 release.

Features (page 17)

Features
This document contains no feature updates in this release.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

18 New in this release

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

19

Introduction
This document contains the fault number description and the maintenance
actions required for the S8000, S8002, S8003, and S8006 BTS.

Prerequisites
It is recommended that the readers also become familiar with the following
technical documents:

Nortel GSM BSS Documentation roadmap (411-9001-000)

Nortel GSM BTS S8000 / S8003 Troubleshooting (411-9001-048)

Nortel GSM BSS Performance Management Observation Counters


Dictionary (411-9001-125)

Nortel GSM OMC-R Commands Reference Objects and Fault menus


(411-9001-128)

Nortel GSM BSC 3000 / TCU 3000 Troubleshooting (411-9001-132)

Nortel GSM BSS Overview (411-9001-001)


Nortel GSM BSS Fault Management Maintenance Principles
(411-9001-039)

Nortel GSM BTS S8002 Troubleshooting (411-9001-084)


Nortel GSM BTS S8006 Troubleshooting (411-9001-085)
Nortel GSM BSC 12000HC/TCU 2G Fault Clearing (411-9001-101)
Nortel GSM BSS Fault Clearing Advanced Maintenance Procedures
(411-9001-105)

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

20 Introduction

Navigation
This document consists of 2 chapters:

Chapter 1 How to use this manual (page 25), "How to use this
manual", describes how to use this maintenance manual.

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers


(page 29), "S8000, S8002, S8003, and S8006 BTS Fault Numbers",
contains the fault number description and the corrective maintenance
procedures applicable to the S8000, S8002, S8003 and S8006 BTS.

Safety regulations
Introduction
All the following steps must be taken during the various cabinet
maintenance procedures in order to guarantee personnel and equipment
safety.
Account must be taken of the following aspects:

general personnel safety instructions


equipment safety instructions

Precautionary messages
Caution, warning, and danger messages indicate possible risks.

CAUTION
Impact on the service and on the equipment

DANGER
Electric shock

DANGER
Environment and personnel protection

CAUTION
ESDS handling precautions

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

Safety regulations 21

Personnel and equipment safety


General personnel safety instructions
The personnel must obey the safety instructions specific to the installation
site:

rules concerning the premises (see instructions posted on site or in


the building)

rules linked to the general personnel safety instructions

The personnel working on the cabinet must be authorized to work


according to the security standards.
The cabinet main external power supply is switched off by opening the
circuit breaker on the operator box.
The mains power supply supplying the cabinet means that no work must
be done on the cabinet internal wiring without first cutting its external
mains power supply.
This BTS has been evaluated under IEEE C95.1 requirements, regarding
safety levels with respect to human exposure to radio frequency
electromagnetic fields, 3 kHz to 300 GHz.
The leakage fields and equivalent power densities are orders of magnitude
less than the maximum permissible exposures (MPEs) given in the IEEE
safety guidelines.

CAUTION
Working instructions
The personnel working on the cabinet must be authorized to
work according to the security standards.

CAUTION
ESDS handling precautions
During all maintenance interventions, and especially when
handling the boards, the operator must wear an antistatic
bracelet.

DANGER
Electric shock
Never replace a power supply when energized.

Equipment safety instructions


S8000 Outdoor BTS The maintenance of an S8000 Outdoor BTS is
possible up to -40 C (~ -40F).
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

22 Introduction

The BTS stays operational with the open doors at -10C (~ -14F) during
three hours, and at -40C (~ -40F) during one hour.
In the case of rainy or snowy weather, do not open the cabinet doors
without a tent set up beforehand.

DANGER
Electric shock
Ensure that the unused power cable for the Type F power
supply module is capped and secured before powering up the
S8003 BTS and/or performing any maintenance procedure (see
the following figure).

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

Safety regulations 23

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

24 Introduction

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

25

Chapter 1 How to use this manual


1.1 Introduction
This manual contains the fault number description and the corrective
maintenance procedures applicable to the S8000, S8002, S8003, and
S8006 BTS for single band GSM 850, 900, 1800, 1900, E--GSM 900, and
GSM-R 900 frequency bands. GSM-R does not apply to the S8006 BTS.
The general principles and messages required for BSS maintenance are
described in Nortel GSM BSS Fault Management - Maintenance Principles
(411-9001-039).
The network maintenance is based on the graphical supervision of the
network.
It is also based on the identification and the replacement of faulty items of
equipment, using the alarms and the notifications.
This process is divided into two steps:

locating and identifying the faulty items of equipment, using information


given in this manual

replacing the faulty items of equipment, using the replacement


procedures given in the manuals that describe the on-site procedures

When a faulty item of equipment sends an alarm to the OMC-R, this


alarm is identified by a fault number. This manual gives the procedures
associated with the various fault numbers.
Throughout this document (or section, as it applies), the terms DRX,
e-DRX, DRX-ND3 and eDRX2 are used indistinctly as DRX unless the
document makes a specific reference.
Alarm notifications and contents include specific information about the
particular type of equipment involved on the alarm. For example, alarms
related to DRX-ND3 will include this specific equipment type throughout
the notification.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

26 Chapter 1 How to use this manual

V15.0 introduced EDGE and other important features, together with


DRX-ND3 full differentiation. DRX-ND3 is not EDGE compatible. For all
EDGE related alarms, the term DRX does not include DRX-ND3. This
equipment type solves obsolescence problems with DRX.

1.2 The types of spontaneous messages


1.2.1 Events detected by the BTS
The following are types of spontaneous message:

spontaneous messages indicating a hardware fault (fault number 1067)

spontaneous messages sent as a warning and indicating a transient


event (fault number 1060)

spontaneous messages indicating the arrival of state changes on an


equipment (fault number 1058)

spontaneous messages indicating a hardware fault without loss of


capacity, triggering no defense actions on the part of the BSC. If there
are defense actions, they are local and controlled by the BTS (fault
number 1067).

1.2.2 Events detected by the BSC


Spontaneous messages are sent by the BSC giving information on the
state of relationship with the BTS or part of it (1051, 1052, 1053, 1054,
1055, 1059, 1073).

1.3 Description of a fault number sheet


A corrective maintenance sheet contains the following information:

the header
the main body composed of eight main paragraphs explaining the fault
number treatment

1.3.1 Header of the sheet


The header contains the following information:

the fault number and possibly the source


the alarm type

1.3.2 Main body of the sheet


The main body contains the following information:

Fault analysis

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

1.4 Help

This paragraph describes the fault.

Reaction of the system

BSC defense
This paragraph describes the defense actions taken by the BSC.

Impact on the service


This paragraph gives the consequences of the alarm for the
service.

Troubleshooting
This paragraph gives the procedures to be followed to repair the fault
and return to the operational conditions.

Preliminary checks
These checks are used to ensure that the fault is confirmed and
that the messages identifying a faulty element are in the OMC-R
logs before the start of repair work.

On-site maintenance (possibly using the OMC-R)


This paragraph is used to start the repair work and to bring the
exchanged element into correct operation.

Additional checks
This paragraph shows how to check that the fault has been
cleared.

1.4 Help
The system provides the user with help at any time. For an in-depth
discussion of Help, refer to Nortel GSM OMC-R Commands Reference Security, Administration, SMS-CB, and Help menus (411-9001-130).
There are two kinds of help available:

on-line help, available from the Help menu in the OMC-R Browser
window, as well as other windows

the Consult BSS Documentation option of the workstation workspace


pop-up menu provides access to on-line BSS documentation stored
on CD-ROM.

Both are provided on the same CD-ROM.

1.4.1 Loading the CD-ROM


To load the CD-ROM from the screen workspace menu, insert the
CD-ROM in the OMC-R server and/or workstation CD-ROM drive.
Installation is complete when the light on the CD-ROM drive is no longer
lit.
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

27

28 Chapter 1 How to use this manual

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

29

Chapter 2 S8000, S8002, S8003, and


S8006 BTS fault numbers
Throughout this document (or section, as it applies), the terms DRX,
e-DRX, DRX-ND3 and eDRX2 are used indistinctly as DRX unless the
document makes a specific reference.
Alarm notifications and contents include specific information about the
particular type of equipment involved on the alarm. For example, alarms
related to DRX-ND3 will include this specific equipment type throughout
the notification.
V15.0 introduced EDGE and other important features, together with
DRX-ND3 full differentiation. DRX-ND3 is not EDGE compatible. For all
EDGE related alarms, the term DRX does not include DRX-ND3. This
equipment type solves obsolescence problems with DRX.

2.1 Fault number: 1051 (S8000, S8002, S8003, and S8006 BTS)
Fault number:
1051

: Loss of layer 3 with remote GSM entity

Type

: communicationsAlarm

This problem is associated with a PCM fault. See 411-9001-105 (Nortel


GSM BSS Fault Clearing - Advanced Maintenance Procedures)

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)
Fault number:
1052

GSM entity downloading failure

Type

communicationsAlarm/processingErrorAlarm/equipmentAlarm

FAULT ANALYSIS
This message identifies the impacted element but not the faulty element. It
indicates a software downloading error concerning a transceiverEquipment
object or a btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

30 Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

All the software downloading attempts are indicated, as well as the source
of their failure.
The following Table 1 "Fault number 1052 sources" (page 30) indicates
all the sources of the fault number 1052 for the S8000 Outdoor and
Indoor BTSs with the BCF or CBCF, the S8002 BTSs, the S8003 indoor
BTSs, and the S8006 BTSs. For more information on each source, refer
to the indicated paragraph to know the corrective maintenance procedure
associated with this source.
Table 1
Fault number 1052 sources
Source No.

Paragraph

Source wording

No response to status request

2.2.1 Source 0: No
response to status
request (page 41)

Bad hardware reference of manufacturer ID

2.2.2 Source 1: Bad


hardware reference
of manufacturer ID
(page 43)

SUP stop receipt

No change to one of BOOT states after reset

2.2.4 Source 3: No
change to one of BOOT
states after reset (page
48)

This entity is engaged in another downloading

2.2.5 Source
4: This entity is
engaged in another
downloadingSource 8:
Wrong software reference
on a non downloadable
TEI (page 52)

Software not compatible with hardware

2.2.6 Source 5: Software


not compatible with
hardware (page 54)

File access error

2.2.7 Source 6: File


access error (page 58)

Repetitive errors (NACK, timeout, ... ) while


downloading a file

2.2.8 Source 7:
Repetitive errors (NACK,
timeout, ...) while
downloading a file
(page 61)

2.2.3 Source 2: SUP stop


receipt (page 46)

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS) 31

Table 1
Fault number 1052 sources (contd.)
Source No.

Paragraph

Source wording

Wrong software reference on a non downloadable TEI

No response to download message

2.2.9 Source 9: No
response to download
message (page 61)

14

CSM load container negative acknowledgement

2.2.10 Source 14:


Received CSM LOAD
CONTAINER NAK
(page 64)

15

File to download empty

2.2.11 Source 15: File


to download empty
(page 66)

16

File to download unavailable

2.2.12 Source 16: File to


download unavailable
(page 68)

17

Buffer allocation failure

2.2.13 Source 17: Buffer


allocation failure (page
69)

18

Bad sending buffer size value

2.2.14 Source 18: Bad


sending buffer size value
(page 72)

19

Failure during OMU switchover

2.2.15 Source 19: Failure


during OMU switchover
(page 74)

20

Bad TEI sent by BTS in the CSM software update


report message

2.2.16 Source 20: Bad


TEI sent by BTS in the
CSM software update
report message (page 76)

21

CSM software update report with the cause "unknown


TEI"

2.2.17 Source 21: CSM


software update report
with the cause - unknown
TEI - (page 78)

22

CSM software update report with the cause "equipment


failure"

2.2.5 Source
4: This entity is
engaged in another
downloadingSource 8:
Wrong software reference
on a non downloadable
TEI (page 52)

2.2.18 Source 22:


CSM software update
report with the cause
- equipment failure -
(page 81)

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

32 Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Table 1
Fault number 1052 sources (contd.)
Source No.

Paragraph

Source wording

23

CSM software update report with the cause


"downloading failure"

24

CSM software update report with the cause "not able


to perform"

2.2.20 Source 24: CSM


software update report
with the cause - not able
to perform- (page 85)

25

CSM software update report with the cause "wrong soft


ref"

2.2.21 Source 25: CSM


software update report
with the cause - wrong
software reference -
(page 87)

26

CSM software update report with the cause "wrong


config ref"

2.2.22 Source 26: CSM


software update report
with the cause - wrong
configuration reference
- (page 90)

27

CSM software update report with the cause "restart


request"

2.2.23 Source 27: CSM


software update report
with the cause - restart
request - (page 92)

28

CSM software update report with the cause "data


inconsistency"

2.2.24 Source 28: CSM


software update report
with the cause - data
inconsistency - (page 94)

29

CSM software update report with the cause "message


out of sequence"

2.2.25 Source 29:


CSM software update
report with the cause message out of sequence
- (page 97)

30

CSM software update report with the cause


"background not available"

2.2.26 Source 30:


CSM software update
report with the cause background not available
- (page 99)

31

CSM software update report with the cause


"incompatible RM version"

2.2.27 Source 31:


CSM software update
report with the cause incompatible RM version
- (page 101)

2.2.19 Source 23:


CSM software update
report with the cause downloading failure -
(page 83)

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS) 33

Table 1
Fault number 1052 sources (contd.)
Source No.

Paragraph

Source wording

32

CSM software update report with the cause


"downloading in progress"

2.2.28 Source 32:


CSM software update
report with the cause downloading in progress
- (page 104)

33

Bad report sent by BTS in the CSM software update


report message

2.2.29 Source 33: Bad


report sent by BTS
in the CSM software
update report message
(page 106)

34

no BTS response on CSM software update init/control


message

35

nack received on the abort requested by operator

2.2.31 Source 35: Nack


received on the abort
requested by operator
(page 111)

36

bad report sent by BTS in the CSM software update


abort message

2.2.32 Source 36: Bad


report sent by BTS
in the CSM software
update abort message
(page 113)

37

no BTS response on CSM software update abort


message

2.2.33 Source 37: No


BTS response on CSM
software update abort
message (page 115)

38

flash activate nack with the cause "unknown TEI"

2.2.34 Source 38: Flash


activate nack with the
cause - unknown TEI
- (page 118)

39

flash activate nack with the cause "equipment failure"

2.2.35 Source 39: Flash


activate nack with the
cause - equipment failure
- (page 120)

40

flash activate nack with the cause "downloading failure"

2.2.36 Source 40: Flash


activate nack with the
cause - downloading
failure - (page 122)

2.2.30 Source 34:


No BTS response on
CSM software update
init-control message
(page 108)

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

34 Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Table 1
Fault number 1052 sources (contd.)
Source No.

Source wording

Paragraph

41

flash activate nack with the cause "not able to perform"

2.2.37 Source 41: Flash


activate nack with the
cause - not able to
perform - (page 124)

42

flash activate nack with the cause "flash inconsistency"

2.2.38 Source 42:


Flash activate nack
with the cause - flash
inconsistency - (page
127)

43

flash activate nack with the cause "data inconsistency"

2.2.39 Source 43: Flash


activate nack with the
cause - data inconsistency
- (page 129)

44

flash activate nack with the cause "wrong soft ref"

2.2.40 Source 44: Flash


activate nack with the
cause - wrong soft ref
- (page 131)

45

flash activate nack with the cause "wrong config ref"

2.2.41 Source 45: Flash


activate nack with the
cause - wrong config ref
- (page 133)

46

CSM downloading start nack with the cause "unknown


TEI"

2.2.42 Source 46: CSM


downloading start nack
with the cause - unknown
TEI - (page 136)

47

CSM downloading start nack with the cause "equipment


failure"

2.2.43 Source 47:


CSM downloading start
nack with the cause
- equipment failure -
(page 138)

48

CSM downloading start nack with the cause


"downloading failure"

2.2.44 Source 48:


CSM downloading start
nack with the cause downloading failure -
(page 140)

49

CSM downloading start nack with the cause "message


out of sequence"

2.2.45 Source 49:


CSM downloading start
nack with the cause message out of sequence
- (page 142)

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS) 35

Table 1
Fault number 1052 sources (contd.)
Source No.

Source wording

Paragraph

50

CSM downloading start nack with the cause "wrong soft


ref"

2.2.46 Source 50: CSM


downloading start nack
with the cause - wrong
soft ref - (page 145)

51

CSM downloading start nack with the cause "wrong


config ref"

2.2.47 Source 51: CSM


downloading start nack
with the cause - wrong
config ref - (page 147)

52

CSM downloading start nack with a bad cause

2.2.48 Source 52:


CSM downloading start
nack with a bad cause
(page 149)

53

no BTS response on CSM downloading start message

2.2.49 Source 53:


No BTS response on
CSM downloading start
message (page 152)

54

CSM downloading end nack with the cause "unknown


TEI"

2.2.50 Source 54: CSM


downloading end nack
with the cause - unknown
TEI - (page 154)

55

CSM downloading end nack with the cause "equipment


failure"

2.2.51 Source 55:


CSM downloading end
nack with the cause
- equipment failure -
(page 156)

56

CSM downloading end nack with the cause


"downloading failure"

2.2.52 Source 56:


CSM downloading end
nack with the cause downloading failure -
(page 158)

57

CSM downloading end nack with the cause "value out


of range"

58

CSM downloading end nack with a bad cause

2.2.54 Source 58:


CSM downloading end
nack with a bad cause
(page 163)

59

no BTS response on CSM downloading end message

2.2.55 Source 59:


No BTS response on
CSM downloading end
message (page 165)

2.2.53 Source 57: CSM


downloading end nack
with the cause - value out
of range - (page 161)

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

36 Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Table 1
Fault number 1052 sources (contd.)
Source No.

Paragraph

Source wording

60

CSM load init nack with the cause "equipment failure"

2.2.56 Source 60: CSM


load init nack with the
cause - equipment failure
- (page 168)

61

CSM load init nack with the cause "downloading failure"

2.2.57 Source 61: CSM


load init nack with the
cause - downloading
failure - (page 170)

62

CSM load init nack with the cause "message out of


sequence"

2.2.58 Source 62: CSM


load init nack with the
cause - message out of
sequence - (page 172)

63

CSM load init nack with the cause "wrong file ref"

2.2.59 Source 63: CSM


load init nack with the
cause - wrong file ref -
(page 174)

64

CSM load init nack with the cause "window size not
allow"

2.2.60 Source 64: CSM


load init nack with the
cause - window size not
allowed - (page 177)

65

CSM load init nack with the cause "data format error"

2.2.61 Source 65: CSM


load init nack with the
cause - data format error
- (page 179)

66

CSM load init nack with a bad cause

2.2.62 Source 66: CSM


load init nack with a bad
cause (page 181)

67

no BTS response on CSM load init message

68

CSM load data nack with the cause "equipment failure"

2.2.64 Source 68: CSM


load data nack with the
cause - equipment failure
- (page 186)

69

CSM load data nack with the cause "downloading


failure"

2.2.65 Source 69: CSM


load data nack with the
cause - downloading
failure - (page 188)

2.2.63 Source 67: No


BTS response on CSM
load init message
(page 183)

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS) 37

Table 1
Fault number 1052 sources (contd.)
Source No.

Paragraph

Source wording

70

CSM load data nack with the cause "message out of


sequence"

2.2.66 Source 70: CSM


load data nack with the
cause - message out of
sequence - (page 190)

71

CSM load data nack with the cause "data format error"

2.2.67 Source 71: CSM


load data nack with the
cause - data format error
- (page 192)

72

CSM load data nack with the cause "window overflow"

2.2.68 Source 72: CSM


load data nack with the
cause - window overflow
- (page 195)

73

CSM load data nack with the cause "data


inconsistency"

2.2.69 Source 73: CSM


load data nack with the
cause - data inconsistency
- (page 197)

74

CSM load data nack with the cause "block not


received"

2.2.70 Source 74: CSM


load data nack with the
cause - block not received
- (page 199)

75

CSM load data nack with the cause "bad block tag"

2.2.71 Source 75: CSM


load data nack with the
cause - bad block tag
- (page 201)

76

CSM load data nack with the cause "checksum error"

2.2.72 Source 76: CSM


load data nack with the
cause - checksum error
- (page 204)

77

CSM load data nack with a bad cause

2.2.73 Source 77: CSM


load data nack with a bad
cause (page 206)

78

unexpected CSM load data ack

2.2.74 Source 78:


Unexpected CSM load
data ack (page 208)

79

no BTS response on CSM load data message

2.2.75 Source 79: No


BTS response on CSM
load data message
(page 210)

80

CSM load end nack with the cause "equipment failure"

2.2.76 Source 80: CSM


load end nack with the
cause - equipment failure
- (page 213)

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

38 Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Table 1
Fault number 1052 sources (contd.)
Source No.

Paragraph

Source wording

81

CSM load end nack with the cause "downloading


failure"

82

CSM load end nack with the cause "value out of range"

83

CSM load end nack with the cause "message out of


sequence"

2.2.79 Source 83: CSM


load end nack with the
cause - message out of
sequence - (page 219)

84

CSM load end nack with the cause "data format error"

2.2.80 Source 84: CSM


load end nack with the
cause - data format error
- (page 222)

85

CSM load end nack with the cause "wrong file ref"

2.2.81 Source 85: CSM


load end nack with the
cause - wrong file ref -
(page 224)

86

CSM load end nack with the cause "data inconsistency"

87

CSM load end nack with the cause "checksum error"

2.2.83 Source 87: CSM


load end nack with the
cause - checksum error
- (page 229)

88

CSM load end nack with a bad cause

2.2.84 Source 88: CSM


load end nack with a bad
cause (page 231)

89

no BTS response on CSM load end message

90

bad report sent by BTS during an internal update

2.2.77 Source 81: CSM


load end nack with the
cause - downloading
failure - (page 215)
2.2.78 Source 82: CSM
load end nack with the
cause - value out of range
- (page 217)

2.2.82 Source 86: CSM


load end nack with the
cause - data inconsistency
- (page 226)

2.2.85 Source 89: No


BTS response on CSM
load end message
(page 233)
2.2.86 Source 90: Bad
report sent by BTS
during an internal update
(page 235)

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS) 39

Table 1
Fault number 1052 sources (contd.)
Source No.

Paragraph

Source wording

91

CSM load init nack with the cause "file already open"

2.2.87 Source 91: CSM


load init nack with the
cause - file already open
- (page 238)

92

CSM load init nack with the cause "invalid mode"

2.2.88 Source 92: CSM


load init nack with the
cause - invalid mode -
(page 240)

93

CSM load init nack with the cause "file cannot be


unloaded"

2.2.89 Source 93: CSM


load init nack with the
cause - file cannot be
unloaded - (page 242)

94

CSM load init nack with the cause "flash flag cannot
access"

2.2.90 Source 94: CSM


load init nack with the
cause - flash flag cannot
access - (page 244)

95

CSM load data nack with the cause "file cannot be


unloaded"

2.2.91 Source 95: CSM


load data nack with the
cause - file cannot be
unloaded - (page 247)

96

CSM load data nack with the cause "flash flag cannot
access"

2.2.92 Source 96: CSM


load data nack with the
cause - flash flag cannot
access - (page 249)

97

CSM load data nack with the cause "boot cannot be


unloaded"

2.2.93 Source 97: CSM


load data nack with the
cause - boot cannot be
unloaded - (page 251)

98

CSM load data nack with the cause "data decode error"

99

CSM load data nack with the cause "table cannot


access"

2.2.95 Source 99: CSM


load data nack with the
cause - table cannot
access - (page 256)

100

CSM load data nack with the cause "ram mapping


error"

2.2.96 Source 100: CSM


load data nack with the
cause - RAM mapping
error - (page 258)

2.2.94 Source 98: CSM


load data nack with the
cause - data decode error
- (page 254)

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

40 Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Table 1
Fault number 1052 sources (contd.)
Source No.

Source wording

Paragraph

101

CSM load data nack with the cause "flash access error"

2.2.97 Source 101: CSM


load data nack with the
cause - flash access error
- (page 260)

102

CSM load data nack with the cause "flash ram error"

2.2.98 Source 102: CSM


load data nack with the
cause - flash RAM error
- (page 263)

103

CSM load data nack with the cause "flash erase error"

2.2.99 Source 103: CSM


load data nack with the
cause - flash erase error
- (page 265)

104

CSM load data nack with the cause "internal abort"

2.2.100 Source 104:


CSM load data nack with
the cause - internal abort
- (page 267)

105

CSM flash activate response with a bad cause

106

DTM error during token allocation

107

CSM software update report with the cause: TRX


software incompatibility

108

Too many different deliveries in the cell group

2.2.101 Source 105:


CSM flash activate
response with a bad
cause (page 269)
2.2.102 Source 106:
DTM error during token
allocation (page 272)
2.2.103 Source
107: CSM software
update report with the
cause: TRX software
incompatibility (page 274)
2.2.104 Source 108:
Too many different
deliveries in the cell
group (page 276)

REACTION OF THE SYSTEM


BSC defense
The BSC attempts a maximum of five BCF or TRX software downloading.
If the five attempts fail, the BSC sends a fault number 1052 and a state
change on the btsSiteManager object to "disabled-failed".
Impact on the service

For the btsSiteManager object


Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS) 41

The site is not downloaded.

CAUTION
Service interruption

For the transceiverEquipment object


The TRX is not downloaded. One TDMA is not configured.

CAUTION
Service reduction

2.2.1 Source 0: No response to status request


Fault number 1052 : GSM entity downloading failure
Source:

(0) No response to status request

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates that the BTS has not replied to the status request.

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
Go to step 4.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

42 Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If a pcmCircuit object is "disabled-failed", look for a fault


number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
Go to step 4.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS) 43

GSM BSS Fault Clearing - Advanced Maintenance


Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.2 Source 1: Bad hardware reference of manufacturer ID


Fault number 1052 : GSM entity downloading failure
Source:

(1) Bad hardware reference of manufacturer ID

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
This source indicates that the first downloading attempt failed.
The alarm indicates that the "hardwareRef" parameter, obtained by
performing the "Display" command on the btsSiteManager object and
the transceiverEquipment object, is not in accordance with the PROM
numbers on the boards.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

44 Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a
fault number concerning PCMs. See Nortel GSM BSS
Fault Clearing - Advanced Maintenance Procedures
(411-9001-105).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2). See Nortel GSM BSS Fault
Clearing - Advanced Maintenance Procedures
(411-9001-105).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS) 45

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 6.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

For the btsSiteManager object

Set the value of the "hardwareRef" parameter to "0".

The procedure is complete.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

46 Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers


For the transceiverEquipment object

Modify the value of the "hardwareRef" parameter: set it to "0".

The procedure is complete.


--End--

2.2.3 Source 2: SUP stop receipt


Fault number 1052 : GSM entity downloading failure
Source:

(2) SUP stop receipt

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates that a supervision stop has been received.

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS) 47

If the fault number 1052 is the only alarm, process the


alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

48 Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the fault number 1052 is the only alarm, process the


alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.4 Source 3: No change to one of BOOT states after reset


Fault number 1052 : GSM entity downloading failure
Source:

(3) No change to one of BOOT states after reset

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

2.2.4.1 FAULT ANALYSIS


This source indicates that no change occurred to one of the Boot states,
after reset.

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS) 49

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Clear the alarm and go to
step 8.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).
If an lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the btsSiteManager object is


"disabled-failed", and if there are other alarms which could
impact the operation of the site, lock the btsSiteManager
object and then unlock it. If the alarm with the fault number
1052 and the source 3 is still present, process the alarm. Go
to step 4.
If other fault numbers are present, such as fault number
1054, process them. Concerning fault number 1054 (loss of
layer 2), see 411-9001-105 (Nortel GSM BSS Fault Clearing Advanced Maintenance Procedures)

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

50 Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

GSM BSS Fault Clearing - Advanced Maintenance


Procedures)).
If an lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled" the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

On-site maintenance using the OMC-R

Set the operationalState of the entity concerned to "locked" then


"unlocked" to restart the downloading.

If the alarm persists, check if the source 1 appears.


If the source 1 appears, treat it. See Paragraph 2.2.2
Source 1: Bad hardware reference of manufacturer ID
(page 43).
If the source 1 does not appear, go to step 5 if the
btsSiteManager object is concerned, or step 6 if the
transceiverEquipment object is concerned.

If the alarm has disappeared, the downloading has restarted.


Go to step 8.

Reset the following items of equipment:

for the S8000 BTS, the active CSWM board of the BCF or the
active CMCF board of the CBCF

for the S8002 BTS and the S8006 BTS, the active CMCF
board
If the alarm persists, go to step 7. Otherwise, go to step 8.

Reset the DRXs.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS) 51

If the alarm persists, go to step 7. Otherwise, go to step 8.


7

Replace successively the following items of equipment until the


alarm disappears:

for the S8000 BTS:


the active CSWM board (Field Replaceable Unit) of
the BCF: refer to 411-9001-048 (Nortel GSM BTS
S8000/S8003 Troubleshooting)
or the active CMCF board (Field Replaceable Unit) of
the CBCF: refer to 411-9001-048 (Nortel GSM BTS
S8000/S8003 Troubleshooting)
then, if necessary, the DRXs (Field Replaceable Unit):
refer to 411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting)

for the S8002 BTS:


the active CMCF board (Field Replaceable Unit) of the
CBCF: refer to 411-9001-084 (Nortel GSM BTS S8002
Troubleshooting)
then, if necessary, the DRXs (Field Replaceable
Unit): refer to 411-9001-084 (Nortel GSM BTS S8002
Troubleshooting)

for the S8003 BTS:


the active CMCF board (Field Replaceable Unit) of
the CBCF: refer to 411-9001-048 (Nortel GSM BTS
S8000/S8003 Troubleshooting).
then, if necessary, the DRXs (Field Replaceable Unit):
refer to 411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting).

for the S8006 BTS:


the active CMCF board (Field Replaceable Unit) of the
CBCF: refer to 411-9001-085 (Nortel GSM BTS S8006
Troubleshooting)
then, if necessary, the DRXs (Field Replaceable
Unit): refer to 411-9001-085 (Nortel GSM BTS S8006
Troubleshooting)

If the alarm has disappeared, go to step 8. Otherwise, call the


manufacturer.
8

The procedure is complete.


--End--

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

52 Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

2.2.5 Source 4: This entity is engaged in another downloading


Source 8: Wrong software reference on a non downloadable TEI
Fault number 1052 : GSM entity downloading failure
Source:

(4) This entity is engaged in another downloading

Source:

(8) Wrong software reference on a non


downloadable TEI

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

2.2.5.1 FAULT ANALYSIS


This source indicates that this entity is engaged in another downloading.

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Clear the alarm and go to
step 4.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If an lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the btsSiteManager object is


"disabled-failed", and if there are other alarms which could
impact the operation of the site, lock the btsSiteManager
object, and then unlock it.
If the alarm with the fault number 1052 and the source 4
or 8 is still present, process the alarm. Go to step 4.
Otherwise, if there are other alarms, such as fault number
1054, process them (concerning fault number 1054 (loss

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS) 53

of layer 2), see 411-9001-105 (Nortel GSM BSS Fault


Clearing - Advanced Maintenance Procedures)

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If an lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the transceiverEquipment object


is "disabled" the TRX is not operational. Do not process

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

54 Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.
On-site maintenance using the OMC-R

Restart the active board of the BCF.

If the alarm has disappeared, go to step 5.


If the alarm persists:
For the BSC 3000, call the manufacturer.

The procedure is complete.


--End--

2.2.6 Source 5: Software not compatible with hardware


Fault number 1052 : GSM entity downloading failure
Source:

(5) Software not compatible with hardware

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

2.2.6.1 FAULT ANALYSIS


This source indicates that the software is not compatible with the
hardware.

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, check
whether the "DRX automatic downloading" is activated or not:
If the "DRX automatic downloading" is activated, go to
step 8.
If the "DRX automatic downloading" is not activated, go
to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS) 55

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Clear the alarm and go to
step 8.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).
If an lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", and if there is an alarm with the fault
number 1054, followed by alarms with fault numbers 1051,
1052, 1053, lock the btsSiteManager object, and then unlock
it. If the alarm with the fault number 1052 and the source 5 is
still present, process the alarm. Go to step 4.
Otherwise, refer to the fault number 1054 (loss of layer
2) (see 411-9001-105 (Nortel GSM BSS Fault Clearing Advanced Maintenance Procedures)).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

56 Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

GSM BSS Fault Clearing - Advanced Maintenance


Procedures) ).
If an lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled" the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of
the transceiverEquipment object.
On-site maintenance using the OMC-R

Check that the value of the "hardwareRef" parameter is


consistent with the PROM numbers on the boards, by performing
a "Display" command on the btsSiteManager object.

If the value of the "hardwareRef" parameter is set to 0:


set the btsSiteManager object to "locked"
set the value of the "hardwareRef" parameter to the one
indicated in the notification
set the btsSiteManager object to "unlocked"

If the value of the "hardwareRef" parameter is correct, go to


step 5.

Ensure the EFT is correct by checking the value of the


"swVersionRunning" parameter by performing the "Display"
command on the software object associated with the bsc object.

If this is the case, set the object concerned to "locked" then


"unlocked".
If the alarm persists, call the manufacturer.
If the alarm has disappeared, go to step 8.

If this is not the case, go to step 6.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS) 57

Set the object concerned to "locked".

Download the correct EFT on the item of equipment according


to the following values.
Field

Meaning

Value

XXX

Type of software

BCF : CBC
TRX : DRX/CDR/EDG

ab

Version number

[00 .. 32]

Sub-version number

CBC : [A ..
DRX : [A ..
CDR : [A ..
EDG : [A ..

H]
H]
H]
H]

Edition number

CBC : [1 ..
DRX : [1 ..
CDR : [1 ..
EDG : [1 ..

8]
8]
8]
8]

ef

Revision factor

CBC : [0 ..
DRX : [0 ..
CDR : [0 ..
EDG : [0 ..

32]
32]
32]
32]

If the name of the EFT is correct, call the manufacturer.


Otherwise, modify the value and set the object concerned to
"unlocked".

If the "Automatic downloading" is activated, the OMC-R starts to


perform the downloading just after it received fault number 1052
cause 5:
a The OMC-R reads the BTS hardware reference quoted in the
fault number.
b The OMC-R deduces the name of the EFT to be downloaded
from a correspondence table.
c The OMC-R searches for the EFT in its database:

If it does not find one, the OMC-R goes to step 9.


If it finds one and only one, the OMC-R goes to step 10.
If it finds more than one, it lets the operator choose.
A critical alarm with fault number 30076 is emitted
to report that the automatic downloading failed (see
411-9001-032 (Nortel GSM OMC-R Routine Maintenance
and Troubleshooting)).

The OMC-R searches for the delivery name of the BTS the DRX
belongs to. Then, for all BTS with the same delivery name under
the same BSC, the OMC-R searches for the right EFT.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

58 Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If it finds one and only one, it selects it. Then it goes to step
10.

If it does not find one, the OMC-R searches for an EFT


suitable to all the BTS with the same delivery name in all the
BSC.
If it finds one and only one, it selects it. Then it goes to
step 10.
If it finds more than one, or none, it lets the operator
choose. A critical alarm with fault number 30076 is
emitted to report that the automatic downloading failed
(see 411-9001-032 (Nortel GSM OMC-R Routine
Maintenance and Troubleshooting)).

10

The OMC-R starts to download the selected EFT:


a If necessary, it downloads the selected EFT to the BSC disc.
b It locks the related transceiverEquipment object instance
c It sets the sWVersionNew parameter of the new
transceiverEquipment software object with the new EFT
name.
d It activates the new version.
e It unlocks the related transceiverEquipment object instance.
f

11

As a consequence, the fault number 1052 with cause 5 is


automatically cleared.

The procedure is complete.


--End--

2.2.7 Source 6: File access error


Fault number 1052 : GSM entity downloading failure
Source:

(6) File access error

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
This source indicates that the first downloading attempt has failed. The
BSC does not find the software files in one partition of its hard disk.

TROUBLESHOOTING
Step

Action

Preliminary checks

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS) 59

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Clear the alarm and go to
step 6.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).
If an lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the btsSiteManager object is


"disabled-failed", and if there are other alarms which could
impact the operation of the site, lock the btsSiteManager
object, and then unlock it.
If the alarm with the fault number 1052 and the source 6
is still present, process the alarm. Go to step 4.
Otherwise, if there are other alarms, such as fault number
1054, process them (concerning fault number 1054 (loss
of layer 2), refer to 411-9001-105 (Nortel GSM BSS Fault
Clearing - Advanced Maintenance Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

60 Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If a bts object is "disabled-dependency", look for alarms


concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If an lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the transceiverEquipment object


is "disabled" the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

On-site maintenance using the OMC-R

Download the software from the MD at the OMC-R to the BSC


disk partition:

To download a BCF software, refer to the downloading


procedure.

To download a TRX software, refer to the downloading


procedure.

Lock the object concerned (either btsSiteManager or


transceiverEquipment object).

Unlock the object concerned.


If the alarm has disappeared, go to step 5.
If the alarm persists:

For the BSC 3000, call the manufacturer.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS) 61

The procedure is complete.


--End--

2.2.8 Source 7: Repetitive errors (NACK, timeout, ...) while


downloading a file
Fault number 1052 : GSM entity downloading failure
Source:

(7) Repetitive errors (NACK, timeout, ...) while


downloading a file

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
This source indicates that the downloading failed after repetitive
downloading errors. The probable cause could be corresponding software
corrupted in BTS active BSC corruption.

TROUBLESHOOTING
Step

Action

Preliminary checks

Lock the btsSiteManager

Cleanup the corresponding BTS software from BSC.

Activate the software.

Download the software from the MD at the OMC-R to the


BSC disk partition.
Unlock the btsSiteManager.

The procedure is complete.


--End--

2.2.9 Source 9: No response to download message


Fault number 1052 : GSM entity downloading failure
Source:

(9) No response to download message

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates that the BTS has not replied to a download
message.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

62 Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS) 63

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

64 Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

2.2.10 Source 14: Received CSM LOAD CONTAINER NAK


Fault number 1052 : GSM entity downloading failure
Source:

(14) Received CSM LOAD CONTAINER NAK

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
This message is received after attempts to download the software are
failed by the BSC. This source is because the Load file of TRX/BCF
residing in the BSC is corrupt.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the Display all


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Clear the alarm and go to
step 6.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If an lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the btsSiteManager object is


"disabled-failed", and if there are other alarms which could
impact the operation of the site, lock the btsSiteManager
object, and then unlock it.

If the alarm with the fault number 1052 and the source 6 is
present, process the alarm. Go to step 4.

if there are other alarms, such as fault number 1054, process


them (concerning fault number 1054 (loss of layer 2), see

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS) 65

411-9001-105 (Nortel GSM BSS Fault Clearing - Advanced


Maintenance Procedures)

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object that is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).
If an lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

66 Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.
On-site maintenance using the OMC-R

Re-download the software from the MD at the OMC--R to the


BSC disk partition:

To download a BCF software, refer to the downloading


procedure.

To download a TRX software, refer to the downloading


procedure.

Lock the object concerned (either btsSiteManager or


transceiverEquipment object).

Unlock the object concerned.


If the alarm persists, call the manufacturer.

The procedure is complete.


--End--

2.2.11 Source 15: File to download empty


Fault number 1052 : GSM entity downloading failure
Source:

(15) File to download empty

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates that the file to download is empty.

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS) 67

Clear the alarm.


The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

68 Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If a bts object is "disabled-dependency", look for alarms


concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.12 Source 16: File to download unavailable


Fault number 1052 : GSM entity downloading failure
Source:

(16) File to download unavailable

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS) 69

FAULT ANALYSIS
This source indicates that the downloading attempt has failed because
the file to be downloaded cannot be found in the catalog file (either
because the catalog file itself is not valid, or the name of the file has been
improperly copied in the BTS or BSC software).

TROUBLESHOOTING
Step

Action

Preliminary checks

Cleanup the load from BTS partition of active BSC hard disk.
Download the software from the MD at the OMC-R to the BSC
disk partition:

To download a BCF software, refer to the downloading


procedure in 411-9001-034 (Nortel GSM BSS Configuration Operating Procedures).

To download TRX software, refer to the downloading


procedure in 411-9001-034 (Nortel GSM BSS Configuration Operating Procedures).

Lock the object concerned (either btsSiteManager or


transceiverEquipment object).

Unlock the object concerned.


If the alarm has disappeared, go to step 3.
If the alarm persists, go to step 2.

Perform one of the following:

For the BSC 3000, call the manufacturer.

The procedure is complete.


--End--

2.2.13 Source 17: Buffer allocation failure


Fault number 1052 : GSM entity downloading failure
Source:

(17) Buffer allocation failure

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a buffer allocation failure.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

70 Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

2.2.13.1 TROUBLESHOOTING
Procedure 1
TROUBLESHOOTING

Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS) 71

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

72 Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

2.2.14 Source 18: Bad sending buffer size value


Fault number 1052 : GSM entity downloading failure
Source:

(18) Bad sending buffer size value

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a bad sending of the buffer size value.

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS) 73

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

74 Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

1054 (loss of layer 2), refer to 411-9001-105 (Nortel


GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.15 Source 19: Failure during OMU switchover


Fault number 1052 : GSM entity downloading failure
Source:

(19) Failure during OMU switchover

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a failure during the OMU switchover.

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS) 75

GSM BSS Fault Clearing - Advanced Maintenance


Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

76 Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.16 Source 20: Bad TEI sent by BTS in the CSM software update
report message
Fault number 1052 : GSM entity downloading failure
Source:

(20) Bad TEI sent by BTS in the CSM software update report
message

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a bad TEI sent by the BTS in the CSM software
update report message.

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS) 77

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

78 Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If a bts object is "disabled-dependency", look for alarms


concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.17 Source 21: CSM software update report with the cause unknown TEI Fault number 1052 : GSM entity downloading failure
Source:

(21) CSM software update report with the cause "unknown TEI"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM software update report with the cause
"unknown TEI".
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS) 79

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

80 Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS) 81

2.2.18 Source 22: CSM software update report with the cause equipment failure Fault number 1052 : GSM entity downloading failure
Source:

(22) CSM software update report with the cause "equipment


failure"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM software update report with the cause
"equipment failure".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

82 Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS) 83

1054 (loss of layer 2), refer to 411-9001-105 (Nortel


GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.19 Source 23: CSM software update report with the cause downloading failure Fault number 1052 : GSM entity downloading failure
Source:

(23) CSM software update report with the cause "downloading


failure"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM software update report with the cause
"downloading failure".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

84 Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

GSM BSS Fault Clearing - Advanced Maintenance


Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS) 85

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.20 Source 24: CSM software update report with the cause - not able
to performFault number 1052 : GSM entity downloading failure
Source:

(24) CSM software update report with the cause "not able to
perform"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM software update report with the cause "not
able to perform".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

86 Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS) 87

If a bts object is "disabled-dependency", look for alarms


concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.21 Source 25: CSM software update report with the cause - wrong
software reference Fault number 1052 : GSM entity downloading failure
Source:

(25) CSM software update report with the cause "wrong software
reference"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

88 Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

FAULT ANALYSIS
This source indicates a CSM software update report with the cause "wrong
software reference".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS) 89

alarm and do not clear it. Wait for a state change of the
btsSiteManager object.
3

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

90 Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

The procedure is complete.


--End--

2.2.22 Source 26: CSM software update report with the cause - wrong
configuration reference Fault number 1052 : GSM entity downloading failure
Source:

(26) CSM software update report with the cause "wrong


configuration reference"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM software update report with the cause "wrong
configuration reference".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS) 91

If the fault number 1052 is the only alarm, process the


alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

92 Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the fault number 1052 is the only alarm, process the


alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.23 Source 27: CSM software update report with the cause - restart
request Fault number 1052 : GSM entity downloading failure
Source:

(27) CSM software update report with the cause "restart request"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM software update report with the cause "restart
request".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS) 93

Clear the alarm.


The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

94 Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If a bts object is "disabled-dependency", look for alarms


concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.24 Source 28: CSM software update report with the cause - data
inconsistency Fault number 1052 : GSM entity downloading failure
Source:

(28) CSM software update report with the cause "data


inconsistency"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS) 95

FAULT ANALYSIS
This source indicates a CSM software update report with the cause "data
inconsistency".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

96 Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

alarm and do not clear it. Wait for a state change of the
btsSiteManager object.
3

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS) 97

The procedure is complete.


--End--

2.2.25 Source 29: CSM software update report with the cause message out of sequence Fault number 1052 : GSM entity downloading failure
Source:

(29) CSM software update report with the cause "message out
of sequence"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM software update report with the cause
"message out of sequence".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

98 Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the fault number 1052 is the only alarm, process the


alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS) 99

If the fault number 1052 is the only alarm, process the


alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.26 Source 30: CSM software update report with the cause background not available Fault number 1052 : GSM entity downloading failure
Source:

(30) CSM software update report with the cause "background


not available"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM software update report with the cause
"background not available".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

100

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

101

If a bts object is "disabled-dependency", look for alarms


concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.27 Source 31: CSM software update report with the cause incompatible RM version Fault number 1052 : GSM entity downloading failure
Source:

(31) CSM software update report with the cause "incompatible


RM version"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

102

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

FAULT ANALYSIS
This source indicates a CSM software update report with the cause
"incompatible RM version".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

103

alarm and do not clear it. Wait for a state change of the
btsSiteManager object.
3

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

104

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

The procedure is complete.


--End--

2.2.28 Source 32: CSM software update report with the cause downloading in progress Fault number 1052 : GSM entity downloading failure
Source:

(32) CSM software update report with the cause "downloading in


progress"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM software update report with the cause
"downloading in progress".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

105

If the fault number 1052 is the only alarm, process the


alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

106

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the fault number 1052 is the only alarm, process the


alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.29 Source 33: Bad report sent by BTS in the CSM software update
report message
Fault number 1052 : GSM entity downloading failure
Source:

(33) Bad report sent by BTS in the CSM software update report
message

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a bad report sent by the BTS in the CSM software
update report message.

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

107

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

108

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If a bts object is "disabled-dependency", look for alarms


concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.30 Source 34: No BTS response on CSM software update


init-control message
Fault number 1052 : GSM entity downloading failure
Source:

(34) No BTS response on CSM software update init/control


message

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

109

FAULT ANALYSIS
This source indicates no BTS response on the CSM software update
init/control message.

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

110

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

alarm and do not clear it. Wait for a state change of the
btsSiteManager object.
3

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

111

The procedure is complete.


--End--

2.2.31 Source 35: Nack received on the abort requested by operator


Fault number 1052 : GSM entity downloading failure
Source:

(35) Nack received on the abort requested by operator

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates that a Nack has been received on the abort
requested by operator.

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

112

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the fault number 1052 is the only alarm, process the


alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

113

If the fault number 1052 is the only alarm, process the


alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.32 Source 36: Bad report sent by BTS in the CSM software update
abort message
Fault number 1052 : GSM entity downloading failure
Source:

(36) Bad report sent by BTS in the CSM software update abort
message

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a bad report sent by the BTS in the CSM software
update abort message.

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

114

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

115

If a bts object is "disabled-dependency", look for alarms


concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.33 Source 37: No BTS response on CSM software update abort


message
Fault number 1052 : GSM entity downloading failure
Source:

(37) No BTS response on CSM software update abort message

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates no BTS response on CSM software update abort
message.
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

116

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

117

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

118

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

2.2.34 Source 38: Flash activate nack with the cause - unknown TEI Fault number 1052 : GSM entity downloading failure
Source:

(38) Flash activate nack with the cause "unknown TEI"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a flash activate nack with the cause unknown TEI.

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

119

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

120

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

1054 (loss of layer 2), refer to 411-9001-105 (Nortel


GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.35 Source 39: Flash activate nack with the cause - equipment
failure Fault number 1052 : GSM entity downloading failure
Source:

(39) Flash activate nack with the cause "equipment failure"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a flash activate nack with the cause "equipment
failure".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

121

GSM BSS Fault Clearing - Advanced Maintenance


Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

122

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.36 Source 40: Flash activate nack with the cause - downloading
failure Fault number 1052 : GSM entity downloading failure
Source:

(40) Flash activate nack with the cause "downloading failure"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a flash activate nack with the cause "downloading
failure".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

123

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

124

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If a bts object is "disabled-dependency", look for alarms


concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.37 Source 41: Flash activate nack with the cause - not able to
perform Fault number 1052 : GSM entity downloading failure
Source:

(41) Flash activate nack with the cause "not able to perform"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a flash activate nack with the cause "not able to
perform".
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

125

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

126

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

127

2.2.38 Source 42: Flash activate nack with the cause - flash
inconsistency Fault number 1052 : GSM entity downloading failure
Source:

(42) Flash activate nack with the cause "flash inconsistency"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a flash activate nack with the cause "flash
inconsistency".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

128

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

129

1054 (loss of layer 2), refer to 411-9001-105 (Nortel


GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.39 Source 43: Flash activate nack with the cause - data
inconsistency Fault number 1052 : GSM entity downloading failure
Source:

(43) Flash activate nack with the cause "data inconsistency"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a flash activate nack with the cause "data
inconsistency".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

130

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

GSM BSS Fault Clearing - Advanced Maintenance


Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

131

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.40 Source 44: Flash activate nack with the cause - wrong soft ref Fault number 1052 : GSM entity downloading failure
Source:

(44) Flash activate nack with the cause "wrong soft ref"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a flash activate nack with the cause "wrong soft ref".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

132

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

133

If a bts object is "disabled-dependency", look for alarms


concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.41 Source 45: Flash activate nack with the cause - wrong config
ref Fault number 1052 : GSM entity downloading failure
Source:

(45) Flash activate nack with the cause "wrong config ref"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a flash activate nack with the cause "wrong config
ref".
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

134

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

135

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

136

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

2.2.42 Source 46: CSM downloading start nack with the cause unknown TEI Fault number 1052 : GSM entity downloading failure
Source:

(46) CSM downloading start nack with the cause "unknown TEI"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM downloading start nack with the cause
"unknown TEI".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

137

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

138

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

1054 (loss of layer 2), refer to 411-9001-105 (Nortel


GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.43 Source 47: CSM downloading start nack with the cause equipment failure Fault number 1052 : GSM entity downloading failure
Source:

(47) CSM downloading start nack with the cause "equipment


failure"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM downloading start nack with the cause
"equipment failure".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

139

GSM BSS Fault Clearing - Advanced Maintenance


Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

140

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.44 Source 48: CSM downloading start nack with the cause downloading failure Fault number 1052 : GSM entity downloading failure
Source:

(48) CSM downloading start nack with the cause "downloading


failure"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM downloading start nack with the cause
"downloading failure".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

141

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

142

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If a bts object is "disabled-dependency", look for alarms


concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.45 Source 49: CSM downloading start nack with the cause message out of sequence Fault number 1052 : GSM entity downloading failure
Source:

(49) CSM downloading start nack with the cause "message out
of sequence"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

143

FAULT ANALYSIS
This source indicates a CSM downloading start nack with the cause
"message out of sequence".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

144

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

alarm and do not clear it. Wait for a state change of the
btsSiteManager object.
3

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

145

The procedure is complete.


--End--

2.2.46 Source 50: CSM downloading start nack with the cause - wrong
soft ref Fault number 1052 : GSM entity downloading failure
Source:

(50) CSM downloading start nack with the cause "wrong soft ref"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM downloading start nack with the cause
"wrong soft ref".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

146

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the fault number 1052 is the only alarm, process the


alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

147

If the fault number 1052 is the only alarm, process the


alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.47 Source 51: CSM downloading start nack with the cause - wrong
config ref Fault number 1052 : GSM entity downloading failure
Source:

(51) CSM downloading start nack with the cause "wrong config
ref"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM downloading start nack with the cause
"wrong config ref".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

148

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

149

If a bts object is "disabled-dependency", look for alarms


concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.48 Source 52: CSM downloading start nack with a bad cause
Fault number 1052 : GSM entity downloading failure
Source:

(52) CSM downloading start nack with a bad cause

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM downloading start nack with a bad cause.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

150

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

151

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

152

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

2.2.49 Source 53: No BTS response on CSM downloading start


message
Fault number 1052 : GSM entity downloading failure
Source:

(53) No BTS response on CSM downloading start message

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates no BTS response on CSM downloading start
message.

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

153

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

154

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

1054 (loss of layer 2), refer to 411-9001-105 (Nortel


GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.50 Source 54: CSM downloading end nack with the cause unknown TEI Fault number 1052 : GSM entity downloading failure
Source:

(54) CSM downloading end nack with the cause "unknown TEI"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM downloading end nack with the cause
"unknown TEI".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

155

GSM BSS Fault Clearing - Advanced Maintenance


Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

156

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.51 Source 55: CSM downloading end nack with the cause equipment failure Fault number 1052 : GSM entity downloading failure
Source:

(55) CSM downloading end nack with the cause "equipment


failure"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM downloading end nack with the cause
"equipment failure".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

157

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

158

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If a bts object is "disabled-dependency", look for alarms


concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.52 Source 56: CSM downloading end nack with the cause downloading failure Fault number 1052 : GSM entity downloading failure
Source:

(56) CSM downloading end nack with the cause "downloading


failure"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

159

FAULT ANALYSIS
This source indicates a CSM downloading end nack with the cause
"downloading failure".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

160

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

alarm and do not clear it. Wait for a state change of the
btsSiteManager object.
3

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

161

The procedure is complete.


--End--

2.2.53 Source 57: CSM downloading end nack with the cause - value
out of range Fault number 1052 : GSM entity downloading failure
Source:

(57) CSM downloading end nack with the cause "value out of
range"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM downloading end nack with the cause "value
out of range".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

162

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the fault number 1052 is the only alarm, process the


alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

163

If the fault number 1052 is the only alarm, process the


alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.54 Source 58: CSM downloading end nack with a bad cause
Fault number 1052 : GSM entity downloading failure
Source:

(58) CSM downloading end nack with a bad cause

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM downloading end nack with a bad cause.

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

164

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Clear the alarm.


The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

165

If a bts object is "disabled-dependency", look for alarms


concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.55 Source 59: No BTS response on CSM downloading end message


Fault number 1052 : GSM entity downloading failure
Source:

(59) No BTS response on CSM downloading end message

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates no BTS response on CSM downloading end
message.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

166

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

167

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

168

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

2.2.56 Source 60: CSM load init nack with the cause - equipment failure
Fault number 1052 : GSM entity downloading failure
Source:

(60) CSM load init nack with the cause "equipment failure"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM load init nack with the cause "equipment
failure".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

169

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

170

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

1054 (loss of layer 2), refer to 411-9001-105 (Nortel


GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.57 Source 61: CSM load init nack with the cause - downloading
failure Fault number 1052 : GSM entity downloading failure
Source:

(61) CSM load init nack with the cause "downloading failure"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM load init nack with the cause "downloading
failure".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

171

GSM BSS Fault Clearing - Advanced Maintenance


Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

172

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.58 Source 62: CSM load init nack with the cause - message out of
sequence Fault number 1052 : GSM entity downloading failure
Source:

(62) CSM load init nack with the cause "message out of
sequence"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM load init nack with the cause "message out of
sequence".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

173

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

174

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If a bts object is "disabled-dependency", look for alarms


concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.59 Source 63: CSM load init nack with the cause - wrong file ref Fault number 1052 : GSM entity downloading failure
Source:

(63) CSM load init nack with the cause "wrong file ref"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM load init nack with the cause "wrong file ref".

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

175

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

176

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

177

2.2.60 Source 64: CSM load init nack with the cause - window size not
allowed Fault number 1052 : GSM entity downloading failure
Source:

(64) CSM load init nack with the cause "window size not
allowed"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM load init nack with the cause "window size
not allowed".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

178

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

179

1054 (loss of layer 2), refer to 411-9001-105 (Nortel


GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.61 Source 65: CSM load init nack with the cause - data format error
Fault number 1052 : GSM entity downloading failure
Source:

(65) CSM load init nack with the cause "data format error"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM load init nack with the cause "data format
error".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

180

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

GSM BSS Fault Clearing - Advanced Maintenance


Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

181

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.62 Source 66: CSM load init nack with a bad cause
Fault number 1052 : GSM entity downloading failure
Source:

(66) CSM load init nack with a bad cause

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM load init nack with a bad cause.

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

182

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

183

If a bts object is "disabled-dependency", look for alarms


concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.63 Source 67: No BTS response on CSM load init message


Fault number 1052 : GSM entity downloading failure
Source:

(67) No BTS response on CSM load init message

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a No BTS response on CSM load init message.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

184

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

185

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

186

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

2.2.64 Source 68: CSM load data nack with the cause - equipment
failure Fault number 1052 : GSM entity downloading failure
Source:

(68) CSM load data nack with the cause "equipment failure"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM load data nack with the cause "equipment
failure".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

187

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

188

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

1054 (loss of layer 2), refer to 411-9001-105 (Nortel


GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.65 Source 69: CSM load data nack with the cause - downloading
failure Fault number 1052 : GSM entity downloading failure
Source:

(69) CSM load data nack with the cause "downloading failure"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM load data nack with the cause "downloading
failure".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

189

GSM BSS Fault Clearing - Advanced Maintenance


Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

190

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.66 Source 70: CSM load data nack with the cause - message out of
sequence Fault number 1052 : GSM entity downloading failure
Source:

(70) CSM load data nack with the cause "message out of
sequence"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM load data nack with the cause "message out
of sequence".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

191

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

192

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If a bts object is "disabled-dependency", look for alarms


concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.67 Source 71: CSM load data nack with the cause - data format
error Fault number 1052 : GSM entity downloading failure
Source:

(71) CSM load data nack with the cause "data format error"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM load data nack with the cause "data format
error".
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

193

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

194

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

195

2.2.68 Source 72: CSM load data nack with the cause - window
overflow Fault number 1052 : GSM entity downloading failure
Source:

(72) CSM load data nack with the cause "window overflow"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM load data nack with the cause "window
overflow".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

196

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

197

1054 (loss of layer 2), refer to 411-9001-105 (Nortel


GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.69 Source 73: CSM load data nack with the cause - data
inconsistency Fault number 1052 : GSM entity downloading failure
Source:

(73) CSM load data nack with the cause "data inconsistency"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM load data nack with the cause "data
inconsistency".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

198

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

GSM BSS Fault Clearing - Advanced Maintenance


Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

199

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.70 Source 74: CSM load data nack with the cause - block not
received Fault number 1052 : GSM entity downloading failure
Source:

(74) CSM load data nack with the cause "block not received"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM load data nack with the cause "block not
received".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

200

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

201

If a bts object is "disabled-dependency", look for alarms


concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.71 Source 75: CSM load data nack with the cause - bad block tag Fault number 1052 : GSM entity downloading failure
Source:

(75) CSM load data nack with the cause "bad block tag"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM load data nack with the cause "bad block
tag".

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

202

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

203

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

204

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

2.2.72 Source 76: CSM load data nack with the cause - checksum error
Fault number 1052 : GSM entity downloading failure
Source:

(76) CSM load data nack with the cause "checksum error"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM load data nack with the cause "checksum
error".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

205

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

206

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

1054 (loss of layer 2), refer to 411-9001-105 (Nortel


GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.73 Source 77: CSM load data nack with a bad cause
Fault number 1052 : GSM entity downloading failure
Source:

(77) CSM load data nack with a bad cause

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM software update report with the cause CSM
load data nack with a bad cause.

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

207

GSM BSS Fault Clearing - Advanced Maintenance


Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, process the
alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

208

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.74 Source 78: Unexpected CSM load data ack


Fault number 1052 : GSM entity downloading failure
Source:

(78) Unexpected CSM load data ack

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates an unexpected CSM load data ack.

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

209

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

210

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If a bts object is "disabled-dependency", look for alarms


concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. Treat the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.75 Source 79: No BTS response on CSM load data message


Fault number 1052 : GSM entity downloading failure
Source:

(79) No BTS response on CSM load data message

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates no BTS response on CSM load data message.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

211

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

212

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. Treat the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

213

2.2.76 Source 80: CSM load end nack with the cause - equipment
failure Fault number 1052 : GSM entity downloading failure
Source:

(80) CSM load end nack with the cause "equipment failure"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM load end nack with the cause "equipment
failure".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

214

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. Treat the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

215

1054 (loss of layer 2), refer to 411-9001-105 (Nortel


GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.77 Source 81: CSM load end nack with the cause - downloading
failure Fault number 1052 : GSM entity downloading failure
Source:

(81) CSM load end nack with the cause "downloading failure"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM load end nack with the cause "downloading
failure".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

216

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

GSM BSS Fault Clearing - Advanced Maintenance


Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. Treat the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

217

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.78 Source 82: CSM load end nack with the cause - value out of
range Fault number 1052 : GSM entity downloading failure
Source:

(82) CSM load end nack with the cause "value out of range"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM load end nack with the cause "value out of
range".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

218

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

219

If a bts object is "disabled-dependency", look for alarms


concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. Treat the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.79 Source 83: CSM load end nack with the cause - message out of
sequence Fault number 1052 : GSM entity downloading failure
Source:

(83) CSM load end nack with the cause "message out of
sequence"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

220

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

FAULT ANALYSIS
This source indicates a CSM load end nack with the cause "message out
of sequence".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not treat the

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

221

alarm and do not clear it. Wait for a state change of the
btsSiteManager object.
3

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. Treat the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

222

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

The procedure is complete.


--End--

2.2.80 Source 84: CSM load end nack with the cause - data format error
Fault number 1052 : GSM entity downloading failure
Source:

(84) CSM load end nack with the cause "data format error"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM load end nack with the cause "data format
error".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

223

If the fault number 1052 is the only alarm, treat the alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. Treat the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

224

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.81 Source 85: CSM load end nack with the cause - wrong file ref Fault number 1052 : GSM entity downloading failure
Source:

(85) CSM load end nack with the cause "wrong file ref"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM load end nack with the cause "wrong file ref".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

225

If a pcmCircuit object is "disabled-failed", look for a fault


number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. Treat the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

226

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

GSM BSS Fault Clearing - Advanced Maintenance


Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.82 Source 86: CSM load end nack with the cause - data
inconsistency Fault number 1052 : GSM entity downloading failure
Source:

(86) CSM load end nack with the cause "data inconsistency"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM load end nack with the cause "data
inconsistency".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

227

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

228

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Clear the alarm.


The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. Treat the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

229

2.2.83 Source 87: CSM load end nack with the cause - checksum error Fault number 1052 : GSM entity downloading failure
Source:

(87) CSM load end nack with the cause "checksum error"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM load end nack with the cause "checksum
error".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

230

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. Treat the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

231

1054 (loss of layer 2), refer to 411-9001-105 (Nortel


GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.84 Source 88: CSM load end nack with a bad cause
Fault number 1052 : GSM entity downloading failure
Source:

(88) CSM load end nack with a bad cause

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM load end nack with a bad cause.

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

232

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

GSM BSS Fault Clearing - Advanced Maintenance


Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. Treat the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

233

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.85 Source 89: No BTS response on CSM load end message


Fault number 1052 : GSM entity downloading failure
Source:

(89) No BTS response on CSM load end message

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates no BTS response on CSM load end message.

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

234

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

235

If a bts object is "disabled-dependency", look for alarms


concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. Treat the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.86 Source 90: Bad report sent by BTS during an internal update
Fault number 1052 : GSM entity downloading failure
Source:

(90) Bad report sent by BTS during an internal update

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a bad report sent by BTS during an internal update.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

236

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

237

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. Treat the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

238

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

2.2.87 Source 91: CSM load init nack with the cause - file already open
Fault number 1052 : GSM entity downloading failure
Source:

(91) CSM load init nack with the cause "file already open"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM load init nack with the cause "file already
open".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

239

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. Treat the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

240

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

1054 (loss of layer 2), refer to 411-9001-105 (Nortel


GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.88 Source 92: CSM load init nack with the cause - invalid mode Fault number 1052 : GSM entity downloading failure
Source:

(92) CSM load init nack with the cause "invalid mode"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM load init nack with the cause "invalid mode".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

241

GSM BSS Fault Clearing - Advanced Maintenance


Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. Treat the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

242

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.89 Source 93: CSM load init nack with the cause - file cannot be
unloaded Fault number 1052 : GSM entity downloading failure
Source:

(93) CSM load init nack with the cause "file cannot be unloaded"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM load init nack with the cause "file cannot be
unloaded".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

243

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

244

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If a bts object is "disabled-dependency", look for alarms


concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. Treat the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.90 Source 94: CSM load init nack with the cause - flash flag cannot
access Fault number 1052 : GSM entity downloading failure
Source:

(94) CSM load init nack with the cause "flash flag cannot
access"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

245

FAULT ANALYSIS
This source indicates a CSM load init nack with the cause "flash flag
cannot access".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not treat the

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

246

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

alarm and do not clear it. Wait for a state change of the
btsSiteManager object.
3

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. Treat the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

247

The procedure is complete.


--End--

2.2.91 Source 95: CSM load data nack with the cause - file cannot be
unloaded Fault number 1052 : GSM entity downloading failure
Source:

(95) CSM load data nack with the cause "file cannot be
unloaded"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM load data nack with the cause "file cannot
be unloaded".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

248

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the fault number 1052 is the only alarm, treat the alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. Treat the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

249

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.92 Source 96: CSM load data nack with the cause - flash flag
cannot access Fault number 1052 : GSM entity downloading failure
Source:

(96) CSM load data nack with the cause "flash flag cannot
access"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM load data nack with the cause "flash flag
cannot access".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

250

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Clear the alarm.


The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. Treat the alarm(s) concerning the
btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

251

If a pcmCircuit object is "disabled-failed", look for a fault


number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.93 Source 97: CSM load data nack with the cause - boot cannot be
unloaded Fault number 1052 : GSM entity downloading failure
Source:

(97) CSM load data nack with the cause "boot cannot be
unloaded"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM load data nack with the cause "boot cannot
be unloaded".

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

252

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

253

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. Treat the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

254

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

2.2.94 Source 98: CSM load data nack with the cause - data decode
error Fault number 1052 : GSM entity downloading failure
Source:

(98) CSM load data nack with the cause "data decode error"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM load data nack with the cause "data decode
error".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

255

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. Treat the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

256

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

1054 (loss of layer 2), refer to 411-9001-105 (Nortel


GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.95 Source 99: CSM load data nack with the cause - table cannot
access Fault number 1052 : GSM entity downloading failure
Source:

(99) CSM load data nack with the cause "table cannot access"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM load data nack with the cause "table cannot
access".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

257

GSM BSS Fault Clearing - Advanced Maintenance


Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. Treat the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

258

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.96 Source 100: CSM load data nack with the cause - RAM mapping
error Fault number 1052 : GSM entity downloading failure
Source:

(100) CSM load data nack with the cause "RAM mapping error"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM load data nack with the cause "RAM mapping
error".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

259

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

260

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If a bts object is "disabled-dependency", look for alarms


concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. Treat the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.97 Source 101: CSM load data nack with the cause - flash access
error Fault number 1052 : GSM entity downloading failure
Source:

(101) CSM load data nack with the cause "flash access error"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM load data nack with the cause "flash access
error".
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

261

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

262

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. Treat the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

263

2.2.98 Source 102: CSM load data nack with the cause - flash RAM
error Fault number 1052 : GSM entity downloading failure
Source:

(102) CSM load data nack with the cause "flash RAM error"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM load data nack with the cause "flash RAM
error".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

264

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. Treat the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

265

1054 (loss of layer 2), refer to 411-9001-105 (Nortel


GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.99 Source 103: CSM load data nack with the cause - flash erase
error Fault number 1052 : GSM entity downloading failure
Source:

(103) CSM load data nack with the cause "flash erase error"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM load data nack with the cause "flash erase
error".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

266

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

GSM BSS Fault Clearing - Advanced Maintenance


Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. Treat the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

267

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.100 Source 104: CSM load data nack with the cause - internal abort
Fault number 1052 : GSM entity downloading failure
Source:

(104) CSM load data nack with the cause "internal abort"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM load data nack with the cause "internal
abort".

TROUBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

268

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

269

If a bts object is "disabled-dependency", look for alarms


concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. Treat the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.101 Source 105: CSM flash activate response with a bad cause
Fault number 1052 : GSM entity downloading failure
Source:

(105) CSM flash activate response with a bad cause

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM flash activate response with a bad cause.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

270

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

TROBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

271

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. Treat the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

272

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

2.2.102 Source 106: DTM error during token allocation


Fault number 1052 : GSM entity downloading failure
Source:

(106) DTM error during token allocation

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a DTM error during token allocation.

TROBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

273

1054 (loss of layer 2), refer to 411-9001-105 (Nortel


GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. Treat the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

274

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

GSM BSS Fault Clearing - Advanced Maintenance


Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.103 Source 107: CSM software update report with the cause: TRX
software incompatibility
Fault number 1052 : GSM entity downloading failure
Source:

(107) CSM software update report with the cause: TRX software
incompatibility

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a CSM software update report with the cause: TRX
software incompatibility.

TROBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

275

GSM BSS Fault Clearing - Advanced Maintenance


Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. Treat the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

276

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.2.104 Source 108: Too many different deliveries in the cell group
Fault number 1052 : GSM entity downloading failure
Source:

(108) Too many different deliveries in the cell group

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates too many different deliveries in the cell group.

TROBLESHOOTING
Step

Action

Preliminary checks

Look at the notification and identify the object concerned.

If the btsSiteManager object is concerned, go to step 2.


If the transceiverEquipment object is concerned, go to step 3.

Check the state of the site by performing the "Display all"


command on the btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.2 Fault number: 1052 (S8000, S8002, S8003, and S8006 BTS)

277

If the operationalState of the btsSiteManager object is


"enabled", the site is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC .

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Otherwise, if there are other alarms, set the
btsSiteManager object to "locked" and then to
"unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object which is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

278

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If a bts object is "disabled-dependency", look for alarms


concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. Treat the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If a lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, treat the alarm.
Go to step 4.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, treat them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not treat the
alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

The procedure is complete.


--End--

2.3 Fault number: 1053 (S8000, S8002, S8003, and S8006 BTS)
Fault number:
1053

GSM entity configuration regression

Type

qualityOfServiceAlarm

FAULT ANALYSIS
The BSC detects a difference of the state between that known by the BSC
and that received from the BTS after a status request.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.3 Fault number: 1053 (S8000, S8002, S8003, and S8006 BTS)

279

REACTION OF THE SYSTEM


BSC defense
The BSC tries to restart the BTS (either the btsSiteManager object or the
transceiverEquipment object), to download it, and to reconfigure it.
Impact on the service

For the btsSiteManager object

CAUTION
Service interruption
For as long as the operationalState of the btsSiteManager
object is "disabled-failed", the site is lost. No service is
provided.

For the transceiverEquipment object

CAUTION
Service reduction
For as long as the operationalState of the transceiverEquip
ment object is "disabled", the TRX and one TDMA are lost.
The service is reduced.

TROUBLESHOOTING
Step

Action

Preliminary checks

Look for a fault number 1067 concerning an item of equipment of


the object mentioned in the alarm (fault number 1053).

If there is an alarm with the fault number 1067 concerning


the CSW1/CSW2 boards, process the alarm with the fault
number 1067 first.

If there is an alarm with the fault number 1067 concerning


the transceiverEquipment object (frame processor or RX
module), process the alarm with the fault number 1067 first.

If there are no alarms with the fault number 1067, go to step


2.

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

280

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Clear the alarm and go to
step 4.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed".
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If an lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Go to step 3.

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational. Do not process the
alarm and do not clear it. Wait for a state change of the
btsSiteManager object.

Wait for the end of restart. Then look for the origin of the
problem by analyzing the notification log and looking at the
notifications with the fault number 1060 that indicate the source
of the BTS restart. Also check whether this is a recurring
problem. If the problem persists, call the manufacturer.

The procedure is complete.


--End--

2.4 Fault number: 1054 (S8000, S8002, S8003, and S8006 BTS)
Fault number:
1054

Loss of layer 2 (or no establishment) with remote GSM entity

Type

communicationsAlarm

This problem is associated with a PCM fault. See 411-9001-105 (Nortel


GSM BSS Fault Clearing - Advanced Maintenance Procedures)

2.5 Fault number: 1055 (S8000, S8002, S8003, and S8006 BTS)
Fault number:
1055

Abis negative acknowledgement indication

Type

communicationsAlarm

FAULT ANALYSIS

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.5 Fault number: 1055 (S8000, S8002, S8003, and S8006 BTS)

281

The BSC sends a spontaneous message 1055 when it receives a


non-acknowledgement message (NACK) from a BTS after a configuration
message.
The following indicates all the sources of the fault number 1055 for the
S8000 Outdoor and Indoor BTSs with the BCF or CBCF, the S8002
BTSs, the S8003 BTSs, and the S8006 BTSs. For more information on
each source, refer to the indicated paragraph to know the corrective
maintenance procedure associated with this source.
Table 2
Fault number 1055 sources
Source
No.

Source wording

Paragraph

Equipment failure

2.5.1 Source 1: Equipment failure (page 284)

Equipment unable to perform such


test

2.5.2 Source 2: Equipment unable to perform


such test (page 285)

Equipment unable to perform such


configuration

2.5.3 Source 3: Equipment unable to perform


such configuration (page 286)

Unknown test

Cell parameters inconsistency

2.5.5 Source 5: Cell parameters inconsistency


(page 288)

Data inconsistency

2.5.6 Source 6: Data inconsistency (page 290)

Value out of range

2.5.7 Source 7: Value out of range (page 291)

TEI not present

Unknown Abis PCM_Time_Slot

2.5.9 Source 9: Unknown Abis PCM_Ti


me_Slot (page 293)

10

Unknown Abis PCM

2.5.10 Source 10: Unknown Abis PCM


(page 293)

11

Wrong software reference

12

Further files required

13

Failure during activation

14

Data format error

2.5.14 Source 14: Data format error


(page 295)

15

Window overflow

2.5.15 Source 15: Window overflow (page 295)

16

Normal completion

17

Transfer aborted

2.5.4 Source 4: Unknown test (page 288)

2.5.8 Source 8: TEI not present (page 292)

2.5.11 Source 11: Wrong software


reference (page 294)
2.5.12 Source 12: Further files required
(page 294)
2.5.13 Source 13: Failure during activation
(page 295)

2.5.16 Source 16: Normal completion


(page 295)
2.5.17 Source 17: Transfer aborted (page 295)

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

282

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Table 2
Fault number 1055 sources (contd.)
Source
No.

Source wording

Paragraph

18

Checksum error

2.5.18 Source 18: Checksum error (page 296)

19

File incomplete

2.5.19 Source 19: File incomplete (page 296)

20

File already present and correct

21

File cannot be downloaded

22

Entity engaged in other download

23

Too many signaling timeslots

24

Too many TEI connection to physical


channel

25

Out of sequence message

26

Incorrect IEI

27

Wrong file reference

28

Bad cell number

2.5.28 Source 28: Bad cell number (page 301)

29

Bad related TEI

2.5.29 Source 29: Bad related TEI (page 301)

30

Bad timeslot

31

Window size not allowed

32

Flash boot required

33

Wrong config reference

34

The BTS has not acknowledged the


TX power consign request

35

Downloading aborted

36

Files missing

37

Buffer overflow

38

Block not received

2.5.20 Source 20: File already present


and correct (page 296)
2.5.21 Source 21: File cannot be downloaded
(page 296)
2.5.22 Source 22: Entity engaged in other
download (page 296)
2.5.23 Source 23: Too many signaling
timeslots (page 297)
2.5.24 Source 24: Too many TEI connections
to physical channel (page 298)
2.5.25 Source 25: Out of sequence
message (page 298)
2.5.26 Source 26: Incorrect IEI (page 300)
2.5.27 Source 27: Wrong file reference
(page 300)

2.5.30 Source 30: Bad timeslot (page 301)


2.5.31 Source 31: Window size not
allowed (page 301)
2.5.32 Source 32: Flash boot required
(page 301)
2.5.33 Source 33: Wrong config reference
(page 302)
2.5.34 Source 34: The BTS has not
acknowledged the TX power consign
request (page 302)
2.5.35 Source 35: Downloading aborted
(page 307)
2.5.36 Source 36: Files missing (page 307)
2.5.37 Source 37: Buffer overflow (page 308)
2.5.38 Source 38: Block not received
(page 308)

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.5 Fault number: 1055 (S8000, S8002, S8003, and S8006 BTS)

283

Table 2
Fault number 1055 sources (contd.)
Source
No.

Source wording

Paragraph

39

Downloading restart

40

Request not supported

41

Downloading failure

42

Start-up failure

43

Maximum number of joker TS

44

Bad chain type

45

Bad radio timeslot reference

46

Bad internal Link EDGE configuration

2.5.46 Source 46: Bad internal Link EDGE


configuration (page 312)

47

Inconsistency mapping

2.5.47 Source 47: Inconsistency mapping


(page 312)

48

Inconsistency number of joker DS0

49

Invalid mode

50

File already open

51

File cannot be unloaded

2.5.51 Source 51: File cannot be unloaded


(page 313)

52

Boot cannot be unloaded

2.5.52 Source 52: Boot cannot be


unloaded (page 313)

53

Data decode error

54

Flash flag cannot access

55

Table cannot access

2.5.55 Source 55: Table cannot access


(page 314)

56

RAM mapping error

2.5.56 Source 56: RAM mapping error


(page 314)

57

Flash access error

2.5.57 Source 57: Flash access error


(page 314)

58

Flash write error

2.5.39 Source 39: Downloading restart


(page 308)
2.5.40 Source 40: Request not supported
(page 308)
2.5.41 Source 41: Downloading failure
(page 308)
2.5.42 Source 42: Start-up failure (page 309)
2.5.43 Source 43: Maximum number of
joker TS (page 309)
2.5.44 Source 44: Bad chain type (page 312)
2.5.45 Source 45: Bad radio timeslot
reference (page 312)

2.5.48 Source 48: Inconsistency number


of joker DS0 (page 313)
2.5.49 Source 49: Invalid mode (page 313)
2.5.50 Source 50: File already open
(page 313)

2.5.53 Source 53: Data decode error


(page 314)
2.5.54 Source 54: Flash flag cannot
access (page 314)

2.5.58 Source 58: Flash write error (page 315)

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

284

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Table 2
Fault number 1055 sources (contd.)
Source
No.

Paragraph

Source wording

59

Flash erase error

60

Internal abort

2.5.60 Source 60: Internal abort (page 315)

61

Equipment not able to get external


synchronization

2.5.61 Source 61: Equipment not able to get


external synchronization (page 315)

62

Synchronization in progress

63

Dynamic Abis feature not supported

2.5.63 Source 63: Dynamic Abis feature


not supported (page 316)

64

Inconsistent number of Joker DS0

2.5.64 Source 64: Inconsistent number


of joker DS0 (page 317)

65

Exceeded DL joker DS0 pool number

2.5.65 Source 65: Exceeded DL joker DS0


pool number (page 319)

255

Non-significant value

2.5.66 Source 255: Non-significant value


(page 321)

2.5.59 Source 59: Flash erase error


(page 315)

2.5.62 Source 62: Synchronization in


progress (page 315)

FAULT LOCATION
The fault can be located on one of the following:

the btsSiteManager
the bts
the transceiver
the transceiverEquipment

2.5.1 Source 1: Equipment failure


Fault number 1055 : Abis negative acknowledgement indication
Source:

(1) Equipment failure

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates an equipment failure.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.5 Fault number: 1055 (S8000, S8002, S8003, and S8006 BTS)

285

2.5.2 Source 2: Equipment unable to perform such test


Fault number 1055 : Abis negative acknowledgement indication
Source:

(2) Equipment unable to perform such test

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
This alarm indicates that the PCM number, the cell number, and/or the
number of time slots declared at the OMC-R are higher than those of the
hardware configuration of the BTS.

REACTION OF THE SYSTEM


BSC defense
None.

For the btsSiteManager object

CAUTION
Service interruption
The site is not configured.
No service is provided.

For the bts object

CAUTION
Service interruption
The cell is not configured.
No service is provided on the cell.

For the transceiver object

CAUTION
Service reduction
The TDMA is not configured.

For the transceiverEquipment object

CAUTION
Service reduction
The TRX is not configured and one TDMA is lost.
The service is reduced.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

286

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

TROUBLESHOOTING
Modify the parameters declared at the OMC-R.

2.5.3 Source 3: Equipment unable to perform such configuration


Fault number 1055 : Abis negative acknowledgement indication
Source:

(3) Equipment unable to perform such configuration

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
This alarm indicates that the TRX configuration is not possible because of
a DRX frequency band error.
The different sources of non-acknowledgement are:

the DRX is configured in an extended cell and the hardware does not
support this configuration

the defined frequency range is not compatible with the radio board
version

the number of PCMs, or cells, or signaling TSs is too large according


to the hardware configuration

one or more frequencies mismatch the DRX frequency band

the number of requested pools is more than the maximum number of


supported pools

more than 16 EDGE TRX in a "dynamic Abis" site

the equipment is unable to perform such configuration. A wrong


external alarm mask can generate this notification

REACTION OF THE SYSTEM


BSC defense The BSC unconfigures the transceiverEquipment object
concerned by the alarm.

CAUTION
Service reduction
The service is reduced.

TROUBLESHOOTING
Step

Action

Perform a "Display" command on the bts object.


Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.5 Fault number: 1055 (S8000, S8002, S8003, and S8006 BTS)

287

The "standardIndicator" parameter indicates the frequency band


associated with the DRX module: "gsm", " gsm850", "dcs1800",
"pcs1900", "R gsm", "gsmdcs" or "dcsgsm".

If the "standardIndicator" parameter is "gsm 850pcs", perform


a "Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX is "gsm850".
If the "transceiverEquipmentClass" parameter is "2", the
DRX is PCS.

If the "standardIndicator" parameter is "pcsgsm850", perform


a "Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX is PCS.
If the "transceiverEquipmentClass" parameter is "2", the
DRX is "gsm850".

If the "standardIndicator" parameter is "gsmdcs", perform a


"Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX is GSM.
If the "transceiverEquipmentClass" parameter is "2", the
DRX is DCS.

If the "standardIndicator" parameter is "dcsgsm", perform a


"Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX is DCS.
If the "transceiverEquipmentClass" parameter is "2", the
DRX is GSM.

Check the DRX frequency band declared at the OMC-R with the
PEC or CPC code of the DRX present in the cabinet.

If the DRX frequency band is the same as the one indicated


by the "transceiverEquipmentClass" parameter, clear the
alarm. Go to step 5.

If the DRX frequency band is not the same as the one


indicated by the "transceiverEquipmentClass" parameter and
if the DRX has just been replaced, go to step 4. Otherwise,
go to step 3.

The alarm may be due to an error in the DRX replacement.


Replace the DRX (as a Field Replaceable Unit) by:

setting the administrativeState of the transceiverEquipment


object corresponding to the faulty DRX to "locked"

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

288

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

CAUTION
Service reduction
In most cases, the transceiverEquipment and one
transceiver are lost.
The service is reduced.

replacing the DRX module. Refer to:


411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting) for the S8000 BTS
411-9001-084 (Nortel GSM BTS S8002 Troubleshooting)
for the S8002 BTS
411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting) for the S8003 BTS
411-9001-085 (Nortel GSM BTS S8006 Troubleshooting)
for the S8006 BTS

Go to step 4.
4

Ensure that the DRX used is correct. Modify the value of the
"transceiverEquipmentClass" parameter according to the DRX
frequency band. Go to step 5.

The procedure is complete.


--End--

2.5.4 Source 4: Unknown test


Fault number 1055 : Abis negative acknowledgement indication
Source:

(4) Unknown test

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates an unknown test.

2.5.5 Source 5: Cell parameters inconsistency


Fault number 1055 : Abis negative acknowledgement indication
Source:

(5) Cell parameters inconsistency

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8006

FAULT ANALYSIS
This alarm indicates that at least one TEI of the list is included in another
bts object than that the cell specified. The list of TEI contains twice the
same TEI.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.5 Fault number: 1055 (S8000, S8002, S8003, and S8006 BTS)

289

REACTION OF THE SYSTEM


BSC defense
None.

For the bts object

CAUTION
Service interruption
The cell is not configured.
No service is provided on the cell.

For the transceiver object

CAUTION
Service reduction
The TDMA is not configured.
The service is reduced.

For the transceiverEquipment object

CAUTION
Service reduction
The TRX is not configured and one TDMA is lost.

TROUBLESHOOTING
Step

Action

Perform a "Display" command on the affected transceiverEqui


pment object.
The "teiTransceiverEqpt" parameter indicates the TEI value
associated with the TRX module.
The value of the "teiTransceiverEqpt" parameter should be within
the range specified by the S8000 BTS engineering rules for the
corresponding configuration reference and associated DLUs.

Lock the affected transceiverEquipment object.

Change the value of "teiTransceiverEqpt" so that it conforms to


the engineering rules specified above.

Unlock the transceiverEquipment object.

Check that the alarm is cleared.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

290

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

The procedure is complete.


--End--

2.5.6 Source 6: Data inconsistency


Fault number 1055 : Abis negative acknowledgement indication
Source:

(6) Data inconsistency

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
This alarm indicates that the PCM list contains identical PCM numbers.

REACTION OF THE SYSTEM


BSC defense
None.

For the btsSiteManager object

CAUTION
Service interruption
The site is not configured.
No service is provided.

For the bts object

CAUTION
Service reduction
The cell is not configured.
No service is provided on the cell.

For the transceiver object

CAUTION
Service reduction
The TDMA is not configured.
The service is reduced.

For the transceiverEquipment object

CAUTION
Service reduction
The TRX is not configured. One TDMA is lost.
The service is reduced.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.5 Fault number: 1055 (S8000, S8002, S8003, and S8006 BTS)

291

TROUBLESHOOTING
Step

Action

Check the PCM cabling.

If the cabling is correct, go to step 2.


If the cabling is not correct, replace the cables as necessary.
If the alarm persists, go to step 2.
If the alarm has disappeared, go to step 3.

Check the configuration associated with the object at the


OMC-R. If necessary, modify the PCM numbers declared at the
OMC-R.

The procedure is complete.


--End--

2.5.7 Source 7: Value out of range


Fault number 1055 : Abis negative acknowledgement indication
Source:

(7) Value out of range

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
This alarm indicates that the cell configuration is not possible due to an
incorrect value.
The different sources of non-acknowledgement are:

BCCH frequency value in no known band


BSIC > 63
Diversity Flag is set to a value other than Enabled or Disabled
Max Power for Cell > 55 dBm
Frequency Hopping Flag is set to a value different from the following:

ENABLED_BCCH_STUFF
ENABLED_NO_BCCH_STUFF
DISABLED_BCCH_STUFF
DISABLED_NO_BCCH_STUFF

Number of frequency band = 0 or > 2

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

292

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Any frequency in the list is in no known band


Number of TEI < 1

REACTION OF THE SYSTEM


BSC defense
None.

For the bts object

CAUTION
Service reduction
The cell is not configured.
No service is provided on the cell.

TROUBLESHOOTING
Modify the values declared out of range at the OMC-R.

2.5.8 Source 8: TEI not present


Fault number 1055 : Abis negative acknowledgement indication
Source:

(8) TEI not present

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
This alarm indicates that the TEI of the associated transceiver equipment
is:

not between 32 and 55

or

is not in the permitted list of TEI of the corresponding CELL


Configuration

REACTION OF THE SYSTEM


BSC defense
None.

For the transceiver object

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.5 Fault number: 1055 (S8000, S8002, S8003, and S8006 BTS)

293

CAUTION
Service reduction
The TDMA is not configured.
The service is reduced.

For the transceiverEquipment object

CAUTION
Service reduction
The TRX is not configured and one TDMA is lost.
The service is reduced.

2.5.9 Source 9: Unknown Abis PCM_Time_Slot


Fault number 1055 : Abis negative acknowledgement indication
Source:

(9) Unknown Abis PCM_Time_Slot

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates an unknown Abis PCM Time Slot.

2.5.10 Source 10: Unknown Abis PCM


Fault number 1055 : Abis negative acknowledgement indication
Source:

(10) Unknown Abis PCM

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
This alarm indicates that the PCM is not present in the PCM list.

REACTION OF THE SYSTEM


BSC defense
None.

For the btsSiteManager object

CAUTION
Service interruption
The site is not configured.
No service is provided.

For the bts object

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

294

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

CAUTION
Service reduction
The cell is not configured.
No service is provided on the cell.

For the transceiver object

CAUTION
Service reduction
The TDMA is not configured.
The service is reduced.

For the transceiverEquipment object

CAUTION
Service reduction
The TRX is not configured. One TDMA is lost.
The service is reduced.

TROUBLESHOOTING
Parameterize the PCM declared unknown at the OMC-R.

2.5.11 Source 11: Wrong software reference


Fault number 1055 : Abis negative acknowledgement indication
Source:

(11) Wrong software reference

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a wrong software reference.

2.5.12 Source 12: Further files required


Fault number 1055 : Abis negative acknowledgement indication
Source:

(12) Further files required

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates that further files are required.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.5 Fault number: 1055 (S8000, S8002, S8003, and S8006 BTS)

2.5.13 Source 13: Failure during activation


Fault number 1055 : Abis negative acknowledgement indication
Source:

(13) Failure during activation

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a failure during activation.

2.5.14 Source 14: Data format error


Fault number 1055 : Abis negative acknowledgement indication
Source:

(14) Data format error

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a data format error.

2.5.15 Source 15: Window overflow


Fault number 1055 : Abis negative acknowledgement indication
Source:

(15) Window overflow

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a window overflow.

2.5.16 Source 16: Normal completion


Fault number 1055 : Abis negative acknowledgement indication
Source:

(16) Normal completion

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a normal completion.

2.5.17 Source 17: Transfer aborted


Fault number 1055 : Abis negative acknowledgement indication
Source:

(17) Transfer aborted

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates an aborted transfer.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

295

296

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

2.5.18 Source 18: Checksum error


Fault number 1055 : Abis negative acknowledgement indication
Source:

(18) Checksum error

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a checksum error.

2.5.19 Source 19: File incomplete


Fault number 1055 : Abis negative acknowledgement indication
Source:

(19) File incomplete

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates an incomplete file.

2.5.20 Source 20: File already present and correct


Fault number 1055 : Abis negative acknowledgement indication
Source:

(20) File already present and correct

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a file already present and correct.

2.5.21 Source 21: File cannot be downloaded


Fault number 1055 : Abis negative acknowledgement indication
Source:

(21) File cannot be downloaded

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates that the file cannot be downloaded.

2.5.22 Source 22: Entity engaged in other download


Fault number 1055 : Abis negative acknowledgement indication
Source:

(22) Entity engaged in other download

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates that the entity is engaged in other download.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.5 Fault number: 1055 (S8000, S8002, S8003, and S8006 BTS)

297

2.5.23 Source 23: Too many signaling timeslots


Fault number 1055 : Abis negative acknowledgement indication
Source:

(23) Too many signaling timeslots

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
This alarm indicates the value of the signaling timeslot number is higher
than 6.

REACTION OF THE SYSTEM


BSC defense
None.

For the btsSiteManager object

CAUTION
Service interruption
The site is not configured.
No service is provided.

For the bts object

CAUTION
Service reduction
The cell is not configured.
No service is provided on the cell.

For the transceiver object

CAUTION
Service reduction
The TDMA is not configured.
The service is reduced.

For the transceiverEquipment object

CAUTION
Service reduction
The TRX is not configured. One TDMA is lost.
The service is reduced.

TROUBLESHOOTING
Modify the value of the signaling timeslot number.
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

298

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

2.5.24 Source 24: Too many TEI connections to physical channel


Fault number 1055 : Abis negative acknowledgement indication
Source:

(24) Too many TEI connections to physical channel

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates that there are too many TEI connections to the
physical channel.

2.5.25 Source 25: Out of sequence message


Fault number 1055 : Abis negative acknowledgement indication
Source:

(25) Out of sequence message

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
This alarm indicates that the site configuration message has been received
twice, but with different values by the BTS on the Abis interface. The
message is not accepted due to the BTS state.

REACTION OF THE SYSTEM


BSC defense
None.

For the btsSiteManager object

CAUTION
Service interruption
The site is not configured.
No service is provided.

For the bts object

CAUTION
Service reduction
The cell is not configured.
No service is provided on the cell.

For the transceiver object

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.5 Fault number: 1055 (S8000, S8002, S8003, and S8006 BTS)

299

CAUTION
Service reduction
The TDMA is not configured.
The service is reduced.

For the transceiverEquipment object

CAUTION
Service reduction
The TRX is not configured. One TDMA is lost.
The service is reduced.

TROUBLESHOOTING
Step

Action

Check the configuration associated with the object.

For the btsSiteManager object:


Check the logical configuration of the btsSiteManager
object (teiBtsSiteManager, bscSitePcmList, radioSiteMask
parameters).
If it is not correct, set the object to "locked".
Modify the configuration.
Set the object to "unlocked".
If it is correct, perform the "Display hardware
configuration" command on the btsSiteManager object to
identify the faulty element.

For the bts object


a. Check the logical configuration of the bts object and its
objects.

If it is not correct, set the object to "locked".


Modify the configuration.
Set the object to "unlocked".

If it is correct, perform the "Display hardware


configuration" command on the btsSiteManager to
identify the faulty element.

b. For the base cabinet associated with the extension


cabinet, set the btsSiteManager object to "locked" then
to "unlocked".
c.

If the problem persists, perform the following on-site


maintenance.

For the S8000 BTS, check the cabling between the


extension cabinet and the BCF or CBCF.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

300

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the problem persists, replace the ALCO or


RECAL board (Field Replaceable Units). Refer
to 411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting)

If the alarm has disappeared, go to step 2.

For the transceiver object


a. Set the administrativeState of the transceiver object to
"shuttingDown".
b. Check the logical configuration of the transceiver object
(channelType, absoluteRFChannelNo parameters for
each channel).
c.

Set the administrativeState of the transceiver object to


"unlocked".

For the transceiverEquipment object


Check the logical configuration of the transceiverEquipment
object (teiTransceiverEqpt parameter).
If it is not correct, set the object to "locked".

Modify the configuration.

Set the object to "unlocked".

If it is correct, perform the "Display hardware


configuration" command on the btsSiteManager object to
identify the faulty element.
2

The procedure is complete.


--End--

2.5.26 Source 26: Incorrect IEI


Fault number 1055 : Abis negative acknowledgement indication
Source:

(26) Incorrect IEI

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates an incorrect IEI.

2.5.27 Source 27: Wrong file reference


Fault number 1055 : Abis negative acknowledgement indication
Source:

(27) Wrong file reference

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.5 Fault number: 1055 (S8000, S8002, S8003, and S8006 BTS)

FAULT ANALYSIS
This source indicates a wrong file reference.

2.5.28 Source 28: Bad cell number


Fault number 1055 : Abis negative acknowledgement indication
Source:

(28) Bad cell number

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a bad cell number.

2.5.29 Source 29: Bad related TEI


Fault number 1055 : Abis negative acknowledgement indication
Source:

(29) Bad related TEI

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a bad related TEI.

2.5.30 Source 30: Bad timeslot


Fault number 1055 : Abis negative acknowledgement indication
Source:

(30) Bad timeslot

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a bad timeslot.

2.5.31 Source 31: Window size not allowed


Fault number 1055 : Abis negative acknowledgement indication
Source:

(31) Window size not allowed

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates that the window size is not allowed.

2.5.32 Source 32: Flash boot required


Fault number 1055 : Abis negative acknowledgement indication
Source:

(32) Flash boot required

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

301

302

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

FAULT ANALYSIS
This source indicates that a flash boot is required.

2.5.33 Source 33: Wrong config reference


Fault number 1055 : Abis negative acknowledgement indication
Source:

(33) Wrong config reference

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a wrong config reference.

2.5.34 Source 34: The BTS has not acknowledged the TX power
consign request
Fault number 1055 : Abis negative acknowledgement indication
Source:

(34) The BTS has not acknowledged the power


consign request

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
This alarm indicates that the power, configured at the OMC-R for the DRX
concerned, is not compatible with the DRX hardware.

REACTION OF THE SYSTEM


BSC defense The BSC configures the transceiverEquipment, but the
associated transceiver object is not configured.
Impact on the service

At least one DRX is lost.

CAUTION
Service reduction
It is possible to lose the entire cell linked to the faulty DRX.

CAUTION
Working instructions
Intervention on the site must be immediate: there is a risk of
service loss.

TROUBLESHOOTING
Step

Action

Preliminary checks
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.5 Fault number: 1055 (S8000, S8002, S8003, and S8006 BTS)

303

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b.

As soon as the site is operational (the operationalState


of the btsSiteManager object will be "enabled"), check if
the alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 8.

Maintenance using the OMC-R

Perform a "Display" command on the bts object to check if the


cells are concentric.

If the "concentric cell" parameter is "monozone", go to step 3.


If the "concentric cell" parameter is "concentric" or "dual
band" or "dual coupling", go to step 5.

Check the value of the "bsTxPwrMax" parameter according to


the following information:

For PA: the value of the "bsTxPwrMax" parameter added to


the value to the attenuation of the combiner must be between

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

304

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

31dBm and 44dBm, or 32dBm at the band limit for only GSM
1900.

For HePA: the value of the "bsTxPwrMax" parameter added


to the value to the attenuation of the combiner must be
between 34dBm and 47dBm.

The "bsTxPwrMax" parameter is a parameter of the


powerControl object associated with the bts object.
The "Attenuation" parameter is obtained by a "Display" command
on the btsSiteManager object.
The following table defines the correct values of the
"bsTxPwrMax" parameter, depending on the combiners used in
the BTS. The "Nack" value is not allowed.
Table 3
PA configuration
Combiners

TxF/D

H2D

H4D

DLU attenuation

51 44

Nack

Nack

Nack

43

Pmax

Nack

Nack

42

Pmax

Nack

Nack

41

Pmax-2

Nack

Nack

40

Pmax-2

Pmax

Nack

39

Pmax-4

Pmax

Nack

38

Pmax-4

Pmax-2

Nack

37

Pmax-6

Pmax-2

Nack

36

Pmax-6

Pmax-4

Pmax

35

Pmax-8

Pmax-4

Pmax

34

Pmax-8

Pmax-6

Pmax-2

33

Pmax-10

Pmax-6

Pmax-2

32

Pmax-10

Pmax-8

Pmax-4

31

Pmax-12

Pmax-8

Pmax-4

30

Pmax-12

Pmax-10

Pmax-6

29

Nack

Pmax-10

Pmax-6

28

Nack

Pmax-12

Pmax-8

27

Nack

Pmax-12

Pmax-8

26

Nack

Nack

Pmax-10

25

Nack

Nack

Pmax-10

24

Nack

Nack

Pmax-12

bsTxPwrMax

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.5 Fault number: 1055 (S8000, S8002, S8003, and S8006 BTS)

Combiners

TxF/D

H2D

H4D

DLU attenuation

23

Nack

Nack

Pmax-12

22 0

Nack

Nack

Nack

Table 4
HePA configuration
Dp

TxF/D

H2D

H4D

51 48

Nack

Nack

Nack

Nack

47

Pmax

Nack

Nack

Nack

46

Pmax

Pmax

Nack

Nack

45

Pmax-2

Nack

Nack

Nack

Nack

Nack

Nack

Pmax

Nack

Combiners
DLU or OMC
attenuation
bsTxPwrMax

44

Pmax-2

43

Pmax-4

42

Pmax-4

41

Pmax-6

40

Pmax-6

Pmax-4

Nack
Pmax-6

Pmax-2

39
38

Nack
Nack

Pmax-8

Pmax-8

Pmax-4

Pmax

Pmax-10

Pmax-10

Pmax-6

Pmax-2

34

Pmax-12

Pmax-12

Pmax-8

Pmax-4

33

Nack

Nack

32

Nack

Nack

Pmax-10

Pmax-6

31

Nack

Nack

30

Nack

Nack

Pmax-12

Pmax-8

29

Nack

Nack

Nack

28

Nack

Nack

Nack

27

Nack

Nack

Nack

26

Nack

Nack

Nack

Pmax-12

25

Nack

Nack

Nack

Nack

24

Nack

Nack

Nack

Nack

23

Nack

Nack

Nack

Nack

37
36
35

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

Pmax-10

305

306

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Combiners

Dp

TxF/D

H2D

H4D

Nack

Nack

Nack

Nack

DLU or OMC
attenuation
22 0

If the value is not correct, change it.


If the value is correct, replace the DRX (Field Replaceable
Unit). Refer to:
411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting) for the S8000 BTS
411-9001-084 (Nortel GSM BTS S8002 Troubleshooting)
for the S8002 BTS
411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting) for the S8003 BTS
411-9001-085 (Nortel GSM BTS S8006 Troubleshooting)
for the S8006 BTS
Go to step 6.

Modify the value of the "bsTxPwrMax" parameter according to


the following information:

For PA: the value of the "bsTxPwrMax" parameter added to


the value to the attenuation of the combiner and reduced of
the value of the "transceiver zone Ref" parameter must be
between 31dBm and 44dBm, or 32dBm at the band limit for
only GSM 1900.

For HePA: the value of the "bsTxPwrMax" parameter added


to the value to the attenuation of the combiner and reduced
of the value of the "transceiver zone Ref" parameter must be
between 34dBm and 47dBm.

The "bsTxPwrMax" parameter is a parameter of the


powerControl object associated with the bts object.
The "transceiver zone Ref" parameter is obtained by performing
a "Display" command on the transceiver object.
The "Attenuation" parameter is obtained by a "Display" command
on the btsSiteManager object. This parameter must not be filled
in for the "dual band" or "dual coupling" values of the "concentric
cell" parameter.
The preceding table defines the correct values of the
"bsTxPwrMax" parameter, depending on the combiners used in
the BTS. The "Nack" value is not allowed. The "transceiver zone
Ref" parameter must also be verified.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.5 Fault number: 1055 (S8000, S8002, S8003, and S8006 BTS)

307

If the value is not correct, change it.


If the value is correct, replace the DRX (Field Replaceable
Unit). Refer to:
Nortel GSM BTS S8000/S8003 Troubleshooting
(411-9001-048) for the S8000 BTS
411-9001-084 (Nortel GSM BTS S8002 Troubleshooting)
for the S8002 BTS
411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting) for the S8003 BTS
411-9001-085 (Nortel GSM BTS S8006 Troubleshooting)
for the S8006 BTS
Go to step 5.

Additional checks

Clear the alarm.

Set the bts object to "locked".

Set the bts object to "unlocked".

The procedure is complete.


--End--

2.5.35 Source 35: Downloading aborted


Fault number 1055 : Abis negative acknowledgement indication
Source:

(35) Downloading aborted

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates that the downloading has been aborted.

2.5.36 Source 36: Files missing


Fault number 1055 : Abis negative acknowledgement indication
Source:

(36) Files missing

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates that files are missing.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

308

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

2.5.37 Source 37: Buffer overflow


Fault number 1055 : Abis negative acknowledgement indication
Source:

(37) Buffer overflow

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a buffer overflow.

2.5.38 Source 38: Block not received


Fault number 1055 : Abis negative acknowledgement indication
Source:

(38) Block not received

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates that a block has not been received.

2.5.39 Source 39: Downloading restart


Fault number 1055 : Abis negative acknowledgement indication
Source:

(39) Downloading restart

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a downloading restart.

2.5.40 Source 40: Request not supported


Fault number 1055 : Abis negative acknowledgement indication
Source:

(40) Request not supported

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a request not supported.

2.5.41 Source 41: Downloading failure


Fault number 1055 : Abis negative acknowledgement indication
Source:

(41) Downloading failure

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a downloading failure..

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.5 Fault number: 1055 (S8000, S8002, S8003, and S8006 BTS)

309

2.5.42 Source 42: Start-up failure


Fault number 1055 : Abis negative acknowledgement indication
Source:

(42) Start-up failure

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a start-up failure.

2.5.43 Source 43: Maximum number of joker TS


Fault number 1055 : Abis negative acknowledgement indication
Source:

(43) Maximum number of joker TS

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
This alarm indicates that there is an inconsistency between the number of
joker TS requested by the operator and the BTS capability.
Joker TS provisioning per TDMA is dependent on hardware constraints
(both BCF/CBCF chains must have the same type of hardware) and also
on existing backhaul configuration.

REACTION OF THE SYSTEM


BSC defense The transceiver object is not configured by the BSC.

For the transceiver object

CAUTION
Service reduction
The TDMA is not configured.
The service is reduced.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

310

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 5.

Maintenance using the OMC-R

Explore the site capability:


a Perform a "Display hardware information" command
("standard" mode) on the btsSiteManager object at the
OMC-R.
The OMC-R displays the site type (BCF, or CBCF with CMCF
phase 1 or phase 2) and state (working or failed).
b Perform a "Display data information" command (with "EDGE"
option) on the btsSiteManager object at the OMC-R.
The OMC-R displays the GPRS and EDGE capabilities
of each TRX. This will give the maximum number of joker
TS supported by the BCF/CBCF and TRXs. Look for the
following items of information:

Hardware btsSiteManager capability

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.5 Fault number: 1055 (S8000, S8002, S8003, and S8006 BTS)

311

Max number of timeslot per transceiverEquipment


for active board (main + joker): see Table 5
"Maximum number of TS (main and joker) per
transceiverEquipment" (page 311) below
Max number of timeslot per transceiverEquipment for
passive board (main + joker):
Duplex site consistency: "identical capabilities" / "non
identical capabilities"

Hardware transceiverEquipment capability


Max number of timeslot (main + joker): see Table
5 "Maximum number of TS (main and joker) per
transceiverEquipment" (page 311) below
GPRS capability: "up to CSx"
EDGE capability: "full" / "none"
As a reminder, here are the permitted maximum
values:

Table 5
Maximum number of TS (main and joker) per transceiverEquipment
Type of site

Maximum number of timeslot (main + joker) per


transceiverEquipment

BCF old GTW PROM

BCF new GTW PROM

CBCF CMCF phase 1

CBCF CMCF phase 2

Check the configuration of the transceiver object concerned, and


compare it with the capabilities analyzed in step 2.
As a reminder, here are the value ranges of the parameters
related to joker TS:

numberOfJokerDS0
[0..4] for S8000 BCF
[0..6] for S8000 CBCF

jokerPerMainTarget
[0..4]
The recommended values are 2, 3 or 4, depending on
operator Abis configuration (numberOfJokerDS0) and
estimated EDGE TDMA throughput.

If the configuration is not correct, set the transceiver object


to "locked".

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

312

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Modify the configuration.


Set the transceiver object to "unlocked".

If the configuration is correct, save the information gathered


in step 2, as well as the site configuration, and then call the
manufacturer.

Check that the alarm is cleared.

The procedure is complete.


--End--

2.5.44 Source 44: Bad chain type


Fault number 1055 : Abis negative acknowledgement indication
Source:

(44) Bad chain type

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a bad chain type.

2.5.45 Source 45: Bad radio timeslot reference


Fault number 1055 : Abis negative acknowledgement indication
Source:

(45) Bad radio timeslot reference

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a bad radio timeslot reference.

2.5.46 Source 46: Bad internal Link EDGE configuration


Fault number 1055 : Abis negative acknowledgement indication
Source:

(46) Bad internal Link EDGE configuration

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a bad internal link EDGE configuration.

2.5.47 Source 47: Inconsistency mapping


Fault number 1055 : Abis negative acknowledgement indication
Source:

(47) Inconsistency mapping

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.5 Fault number: 1055 (S8000, S8002, S8003, and S8006 BTS)

FAULT ANALYSIS
This source indicates an inconsistency mapping.

2.5.48 Source 48: Inconsistency number of joker DS0


Fault number 1055 : Abis negative acknowledgement indication
Source:

(48) Inconsistency number of joker DS0

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates an inconsistency number of joker DS0.

2.5.49 Source 49: Invalid mode


Fault number 1055 : Abis negative acknowledgement indication
Source:

(49) Invalid mode

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates an invalid mode.

2.5.50 Source 50: File already open


Fault number 1055 : Abis negative acknowledgement indication
Source:

(50) File already open

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates that the file is already open.

2.5.51 Source 51: File cannot be unloaded


Fault number 1055 : Abis negative acknowledgement indication
Source:

(51) File cannot be unloaded

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates that the file cannot be unloaded.

2.5.52 Source 52: Boot cannot be unloaded


Fault number 1055 : Abis negative acknowledgement indication
Source:

(52) Boot cannot be unloaded

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

313

314

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

FAULT ANALYSIS
This source indicates that the boot cannot be unloaded.

2.5.53 Source 53: Data decode error


Fault number 1055 : Abis negative acknowledgement indication
Source:

(53) Data decode error

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a data decode error.

2.5.54 Source 54: Flash flag cannot access


Fault number 1055 : Abis negative acknowledgement indication
Source:

(54) Flash flag cannot access

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates an access problem to the flash flag.

2.5.55 Source 55: Table cannot access


Fault number 1055 : Abis negative acknowledgement indication
Source:

(55) Table cannot access

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates an access problem to a table.

2.5.56 Source 56: RAM mapping error


Fault number 1055 : Abis negative acknowledgement indication
Source:

(56) RAM mapping error

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a RAM mapping error.

2.5.57 Source 57: Flash access error


Fault number 1055 : Abis negative acknowledgement indication
Source:

(57) Flash access error

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.5 Fault number: 1055 (S8000, S8002, S8003, and S8006 BTS)

315

FAULT ANALYSIS
This source indicates a flash access error.

2.5.58 Source 58: Flash write error


Fault number 1055 : Abis negative acknowledgement indication
Source:

(58) Flash write error

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a flash write error.

2.5.59 Source 59: Flash erase error


Fault number 1055 : Abis negative acknowledgement indication
Source:

(59) Flash erase error

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a flash erase error.

2.5.60 Source 60: Internal abort


Fault number 1055 : Abis negative acknowledgement indication
Source:

(60) Internal abort

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates an internal abort.

2.5.61 Source 61: Equipment not able to get external synchronization


Fault number 1055 : Abis negative acknowledgement indication
Source:

(61) Equipment not able to get external synchronization

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates that an equipment is not able to get the external
synchronization.

2.5.62 Source 62: Synchronization in progress


Fault number 1055 : Abis negative acknowledgement indication
Source:

(62) Synchronization in progress

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

316

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

FAULT ANALYSIS
This source indicates a synchronization in progress.

2.5.63 Source 63: Dynamic Abis feature not supported


Fault number 1055 : Abis negative acknowledgement indication
Source:

(63) Dynamic Abis feature not supported

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
At the reception of a "site config" message with dynamic Abis feature
activated, if one of the CMCF of the BTS is a phase 1, a "site config Nack"
message with the cause Dynamic Abis feature not supported is sent to
the BSC. The BSC must stop the configuration of the BTS.
Besides, in case of inconsistencies detected by the BTS, the BTS sends a
"traffic connect Nack" message with the cause Dynamic Abis feature not
supported (in response of a received "traffic connect" message)
Moreover in case a BTS is equipped with an eDRX that supports the
dynamic Abis feature, but with an S8000 BCF, then the dynamic Abis
feature is not supported by the BTS.
REACTION OF THE SYSTEM
BSC defense
The BSC stops the configuration of the BTS.
Impact on the service

CAUTION
Service reduction
The BTS is not configured.

TROUBLESHOOTING
Modify the BTS configuration:

either deactivate the dynamic Abis feature


or upgrade the BTS (replace CMCF phase 1 with CMCF phase 2, or
replace BCF with CBCF)

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.5 Fault number: 1055 (S8000, S8002, S8003, and S8006 BTS)

317

2.5.64 Source 64: Inconsistent number of joker DS0


Fault number 1055 : Abis negative acknowledgement indication
Source:

(64) Inconsistent number of joker DS0

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
When proceeding with the dynamic Abis feature, the BTS receives the
following information from the BSC: a poolRef which represents the
pool reference on Abis to which a EDGE TDMA belongs (traffic connect
message)
If the BSC has requested more jokers in the pool than the capacity
indicated through the status report message, then this is a case of internal
inconsistencies detected by the BTS, and as a consequence the BTS
sends a traffic connect nack message (in response of a received traffic
connect message) with the cause 64 "Inconsistent number of joker DS0".
Then this alarm indicates that the number of DS0 inside one poolRef
exceeds the pool maximum capability.
REACTION OF THE SYSTEM
BSC defense
None.
Impact on the service

For the transceiverEquipment object

CAUTION
Service reduction
The TRX is not configured. One TDMA is lost.
The service is reduced.

TROUBLESHOOTING
Preliminary checks

Step

Action

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

318

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Clear the alarm.


The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object that is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).
If an lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 6.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.
As soon as the TRX is operational (the operationalState
of the transceiverEquipment object will be "enabled"),
check if the alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 3.

Maintenance using the OMC-R

Set the object concerned to "locked", then to "unlocked".

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.5 Fault number: 1055 (S8000, S8002, S8003, and S8006 BTS)

319

If the alarm persists, call the manufacturer.


If the alarm has disappeared, go to step 3.

The procedure is complete.


--End--

2.5.65 Source 65: Exceeded DL joker DS0 pool number


Fault number 1055 : Abis negative acknowledgement indication
Source:

(65) Exceeded DL joker DS0 pool number

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
When proceeding with the dynamic Abis feature, the BTS receives the
following information from the BSC: a poolRef which represents the
pool reference on Abis to which a EDGE TDMA belongs (traffic connect
message)
If the BSC has requested more jokers in the pool than the capacity
indicated through the status report message, then this is a case of internal
inconsistencies detected by the BTS, and as a consequence the BTS
sends a traffic connect nack message (in response of a received traffic
connect message) with the cause 65 "Exceeded DL joker DS0 pool
number".
REACTION OF THE SYSTEM
BSC defense
None.
Impact on the service

For the transceiverEquipment object

CAUTION
Service reduction
The TRX is not configured. One TDMA is lost.
The service is reduced.

TROUBLESHOOTING

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

320

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers


Procedure 2
Preliminary checks

Step

Action

Check the state of the TRX by performing the "Display all"


command on the transceiverEquipment object.

If the operationalState of the transceiverEquipment object is


"enabled", the TRX is operational.
Clear the alarm.
The procedure is complete.

If the operationalState of the transceiverEquipment object is


"disabled-dependency", the TRX is not operational.
Look for a parent object that is not operational.
If a bts object is "disabled-dependency", look for alarms
concerning cells.
If the btsSiteManager object is "disabled-failed", the site
is not operational. process the alarm(s) concerning the
btsSiteManager object.
If a pcmCircuit object is "disabled-failed", look for a fault
number concerning PCMs (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).
If an lapdLink object is "disabled-failed", the BSC is
concerned. Look for alarms concerning the BSC.

If the operationalState of the transceiverEquipment object is


"disabled-failed", the TRX is not operational.
If the fault number 1052 is the only alarm, process the
alarm. Go to step 6.
Otherwise, if there are other alarms, set the
transceiverEquipment object to "locked" and then
to "unlocked" to confirm the problem.

If the fault number 1052 is still present, treat it (see


above).

If other fault numbers are present, such as fault


number 1054, process them (concerning fault number
1054 (loss of layer 2), refer to 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).

If the operationalState of the transceiverEquipment object


is "disabled", the TRX is not operational. Do not process
the alarm and do not clear it. Wait for a state change of the
transceiverEquipment object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.6 Fault number: 1056 (S8000, S8002, S8003, and S8006 BTS)

321

As soon as the TRX is operational (the operationalState


of the transceiverEquipment object will be "enabled"),
check if the alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 3.

Maintenance using the OMC-R

Set the object concerned to "locked", then to "unlocked".

If the alarm persists, call the manufacturer.


If the alarm has disappeared, go to step 3.

The procedure is complete.


--End--

2.5.66 Source 255: Non-significant value


Fault number 1055 : Abis negative acknowledgement indication
Source:

(255) Non-significant value

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a non-significant value.

2.6 Fault number: 1056 (S8000, S8002, S8003, and S8006 BTS)
Fault number:
1056

Incorrect parameter settings at the OMC-R

Type

equipmentAlarm

FAULT ANALYSIS
Fault number 1056 is sent when BSC detects an incorrect BDA
configuration for a btsSiteManager, bts, transceiverEquipment or
transceiver.
REACTION OF THE SYSTEM
The managed object stays in a disabled/failed state.
Impact on the service

For the btsSiteManager object

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

322

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

CAUTION
Service interruption
The site is not downloaded.

For the transceiverEquipment object

CAUTION
Service reduction
The TRX is not downloaded. One TDMA is not configured.

TROUBLESHOOTING
Step

Action

Lock the impacted bts object.

Correct the OMC-R parameters.

If the parameters are correct, perform an audit BDA on the


BSC.
If the audit does not reveal inconsistencies between the
BDA and the BDE, go to step 3.
If the audit reveals differences, perform a "off line reset
BDA". Then execute a "build BDA" of the BSC (always
in automatic mode). For more information on these
commands, refer to Nortel GSM BSS Configuration Operating Procedures (411-9001-034). Then go to step 3.

Unlock the bts object.


--End--

Table 6
Fault number 1056 sources
Source
No.

Paragraph

Source wording

Incorrect priority on transceiver

2.6.1 Source 0: Incorrect


priority on transceiver
(page 324)

Incorrect setting of channel on


transceiver

2.6.2 Source 1: Incorrect


setting of channel on
transceiver (page 324)

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.6 Fault number: 1056 (S8000, S8002, S8003, and S8006 BTS)

323

Table 6
Fault number 1056 sources (contd.)
Source
No.

Paragraph

Source wording

Cell without BCCH TDM

2.6.3 Source 2: Cell without


BCCH TDM (page 324)

Radio Time Slot not used

2.6.4 Source 3: Radio Time


Slot not used (page 325)

Wrong value for BSS TEI in T1


mode

Cell cfg with cavity and dual band


not acceptable

2.6.6 Source 5: Cell cfg with


cavity and dual band not
acceptable (page 325)

Missing Site management Abis GSM


function

2.6.7 Source 6: Missing


Site management Abis GSM
function (page 325)

Missing Abis Signalling management


Abis GSM function

2.6.8 Source 7: Missing


Abis Signalling management
Abis GSM function (page
325)

Missing Abis Traffic management


Abis GSM function

Missing RfTrans management Abis


GSM function

2.6.10 Source 9: Missing


RfTrans management Abis
GSM function (page 326)

10

Missing cell management Abis GSM


function

2.6.11 Source 10: Missing


cell management Abis GSM
function (page 326)

11

Missing TDMA management Abis


GSM function

2.6.12 Source 11: Missing


TDMA management Abis
GSM function (page 326)

12

Missing TS management Abis GSM


function

2.6.13 Source 12: Missing


TS management Abis GSM
function (page 327)

2.6.5 Source 4: Wrong


value for BSS TEI in T1
mode (page 325)

2.6.9 Source 8: Missing


Abis traffic management
Abis GSM function
(page 326)

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

324

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Table 6
Fault number 1056 sources (contd.)
Source
No.

Paragraph

Source wording

13

The TDMA exists in RDC but the


object was not created.

2.6.14 Source 13: The


TDMA exists in RDC but
the object was not created.
(page 327)

14

Too many EDGE TDMAs (>16 per


site) configured

2.6.15 Source 14: Too


many EDGE TDMAs (more
than 16 per site) configured
(page 327)

2.6.1 Source 0: Incorrect priority on transceiver


Fault number 1056

Incorrect parameter setting at the OMC-R level

Source:

(0) Incorrect priority on transceiver

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This alarm indicates an incorrect priority setting on the transceiver, at the
OMC-R.

2.6.2 Source 1: Incorrect setting of channel on transceiver


Fault number 1056

Incorrect parameter setting at the OMC-R level

Source:

(1) Incorrect setting of channel on transceiver

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This alarm indicates an incorrect setting of channel on the transceiver
object at the OMC-R.

2.6.3 Source 2: Cell without BCCH TDM


Fault number 1056

Incorrect parameter setting at the OMC-R level

Source:

(2) Cell without BCCH TDM

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This alarm indicates a cell without BCCH TDM.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.6 Fault number: 1056 (S8000, S8002, S8003, and S8006 BTS)

2.6.4 Source 3: Radio Time Slot not used


Fault number 1056

Incorrect parameter setting at the OMC-R level

Source:

(3) Radio Time Slot not used

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This alarm indicates a radio Time Slot not used.

2.6.5 Source 4: Wrong value for BSS TEI in T1 mode


Fault number 1056

Incorrect parameter setting at the OMC-R level

Source:

(4) Wrong value for BSS TEI in T1 mode

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This alarm indicates a wrong value for BSS TEI in T1 mode.

2.6.6 Source 5: Cell cfg with cavity and dual band not acceptable
Fault number 1056

Incorrect parameter setting at the OMC-R level

Source:

(5) Cell cfg with cavity and dual band not acceptable

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This alarm indicates a cell configuration with cavity and dual band (not
acceptable).

2.6.7 Source 6: Missing Site management Abis GSM function


Fault number 1056

Incorrect parameter setting at the OMC-R level

Source:

(6) Missing Site management Abis GSM function

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This alarm indicates a missing Site management Abis GSM function.

2.6.8 Source 7: Missing Abis Signalling management Abis GSM


function
Fault number 1056

Incorrect parameter setting at the OMC-R level

Source:

(7) Missing Abis Signalling management Abis GSM function

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

325

326

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

FAULT ANALYSIS
This alarm indicates a Missing Abis Signalling management Abis GSM
function.

2.6.9 Source 8: Missing Abis traffic management Abis GSM function


Fault number 1056

Incorrect parameter setting at the OMC-R level

Source:

(8) Missing Abis traffic management Abis GSM function

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This alarm indicates a missing Abis traffic management Abis GSM
function.

2.6.10 Source 9: Missing RfTrans management Abis GSM function


Fault number 1056

Incorrect parameter setting at the OMC-R level

Source:

(9) Missing RfTrans management Abis GSM function

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This alarm indicates a missing RfTrans management Abis GSM function.

2.6.11 Source 10: Missing cell management Abis GSM function


Fault number 1056

Incorrect parameter setting at the OMC-R level

Source:

(10) Missing cell management Abis GSM function

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This alarm indicates a missing cell management Abis GSM function.

2.6.12 Source 11: Missing TDMA management Abis GSM function


Fault number 1056

Incorrect parameter setting at the OMC-R level

Source:

(11) Missing TDMA management Abis GSM function

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This alarm indicates a missing TDMA management Abis GSM function.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.7 Fault number: 1058 (S8000, S8002, S8003, and S8006 BTS)

327

2.6.13 Source 12: Missing TS management Abis GSM function


Fault number 1056

Incorrect parameter setting at the OMC-R level

Source:

(12) Missing TS management Abis GSM function

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This alarm indicates a missing TS management Abis GSM function.

2.6.14 Source 13: The TDMA exists in RDC but the object was not
created.
Fault number 1056

Incorrect parameter setting at the OMC-R level

Source:

(13) The TDMA exists in RDC but the object was not created.

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This alarm indicates that the TDMA exists in RDC but the object was not
created.

2.6.15 Source 14: Too many EDGE TDMAs (more than 16 per site)
configured
Fault number 1056

Incorrect parameter setting at the OMC-R level

Source:

(14) Too many EDGE TDMAs (>16 per site) configured

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This alarm indicates that too many EDGE TDMAs (>16 per site) are
configured.

2.7 Fault number: 1058 (S8000, S8002, S8003, and S8006 BTS)
Fault number:
1058

GSM entity configuration regression

Type

processingErrorAlarm

REACTION OF THE SYSTEM


This alarm indicates an entity of the BTS detects an anomaly in its
configuration, reports it to the BSC via this alarm, and de-configures itself.
BSC defense

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

328

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the site is operational, the BSC unconfigures the btsSiteManager


object and tries to reconfigure it.

If the site is not operational, there is a connection problem between the


actual connections and the connections declared at the OMC-R.

Impact on the service

For the btsSiteManager object

CAUTION
Service interruption
As long as the operationalState of the btsSiteManager
object is "disabled-f ailed", the site is lost.
No service is provided.

For the transceiverEquipment object

CAUTION
Service reduction
As long as the operationalState of the transceiverEquipment
object is "disabled", the TRX and one TDMA are lost.
The service is reduced.

TROUBLESHOOTING
Step

Action

On-site maintenance using the OMC-R

Set the pcmCircuit object to "locked".

Untwine the PCM links.

Set the pcmCircuit object to "unlocked".

If the alarm has disappeared, go to step 4.


If the alarm persists, call the manufacturer.

The procedure is complete.


--End--

2.8 Fault number: 1059 (S8000, S8002, S8003, and S8006 BTS)
Fault number:
1059

Invalid message received on Abis interface on O and M link

Type

communicationsAlarm

FAULT ANALYSIS
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.9 Fault number: 1060 (S8000, S8002, S8003, and S8006 BTS)

329

The BSC receives a message from the BTS that it cannot treat for one of
the following reasons:

the message is out of sequence


the message concerns an unknown element, for example, a distant
item of equipment not created at the OMC-R but emitting notifications

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
None.
TROUBLESHOOTING

For a message on an unknown element (an element not declared at


the OMC-R), switch off the concerned element.

Otherwise, no maintenance action is required.

WARNING
If several 1059 fault numbers are detected by the same cell, call
the manufacturer.

2.9 Fault number: 1060 (S8000, S8002, S8003, and S8006 BTS)
Attribute value change
1060

Abis event reporting a transient default

Type

equipmentAlarm

The spontaneous message 1060 accepts causes and equipment wordings


corresponding to the DRX, eDRX, eDRX2, ND3, ePA, HePA, CMCF phase
1 and CMCF phase 2 fault causes.
The warning 1060 (transient) and the fault number 1067 (begin/end)
accept these items of equipment. The causes are the same for all the DRX
types fault causes.
The spontaneous message 1060 corresponds to a warning and does not
require a maintenance action, except in conjunction with the fault number
1067.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

330

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

The following table indicates all the sources of the fault number 1060 for
the S8000 Outdoor and Indoor BTSs with the BCF or CBCF, the S8002
BTSs, the S8003 BTSs, and the S8006 BTSs. For more information on
each source, refer to the indicated paragraph to know the corrective
maintenance procedure associated with this source.
Table 7
Fault number 1060 sources
Source
wording

Source No.

S8000
Indoor
BCF

CBCF

S8000 Out
door
BCF

CBC
F

S800
2

S8003

S8006

Paragra
ph

Battery cabinet
5832705

Over tempe
rature

5832706

DC power
fault

5832707

Doors

5832708

AC power
fault

5832709

Surge
protector

Battery Remote Controller (BRC)


6553601

Manual
switch on
battery
power

2.9.1
BRC
(source:
Manual
switch on
battery
power)
(page
351)

6553602

Automatic
switch on
battery
power

2.9.2
BRC (so
urce: Au
tomatic
switch on
battery
power)
(page
351)

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.9 Fault number: 1060 (S8000, S8002, S8003, and S8006 BTS)

Source No.

Source
wording

S8000
Indoor
BCF

CBCF

S8000 Out
door
BCF

CBC
F

S800
2

S8003

S8006

331

Paragra
ph

6553603

Manual
switch on
main power

2.9.3
BRC
(source:
Manual
switch
on main
power)
(page
351)

6553604

Automatic
switch on
main power

2.9.4
BRC
(source:
Automat
ic switch
on main
power)
(page
352)

Cavity
8388609

Cavity out
of service

2.9.5
Cavity
(source:
Cavity
parked
after tun
ing fault
(min not
found))
(page
352)

2.9.6
Cavity
(source:
Nack ans
wer from
cavity)
(page
354)

Cavity
parked after
tuning fault
(min not
found)
8388610

8388611

Loss of
cavity initi
alization
Nack answe
r from cavity

8388612

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

332

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Source
wording

Source No.

S8000
Indoor
BCF

CBCF

S8000 Out
door
BCF

CBC
F

S800
2

S8003

S8006

2.9.7
Cavity
(source:
Cavity
parked
after tun
ing fault
(power
too low))
(page
354)

2.9.8
Cavity
(source:
Cavity
parked
after tun
ing fault
(tuning
detector
)) (page
355)

Cavity
parked after
tuning fault
(power too
low)
8388613

8388614

8388615

Cavity
parked
after tuning
fault (tuning
detector
problem)

Internal
software
problem

Paragra
ph

C-DACS climatic system


7929857

Dirty filter

7929858

DACS failed

CMCF
CMCF phase 1
CMCF phase 2
9502722
12779522
12845058

Unknown
message

CMCF
CMCF phase 1
CMCF phase 2

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.9.9
CMCF
board
(source:
Unknown
message
) (page
355)

2.9 Fault number: 1060 (S8000, S8002, S8003, and S8006 BTS)

Source No.

Source
wording

S8000
Indoor
BCF

CBCF

S8000 Out
door
BCF

CBC
F

333

S800
2

S8003

S8006

Paragra
ph

9502752
12779552
12845088

Restart due
to reset by
BSC

9502753
12779553
12845089

Restart due
to reset by
reset button

9502754
12779554
12845090

Restart due
to power on

9502755
12779555
12845091

Restart due
to a too
long PCM
scanning

9502756
12779556
12845092

Restart
requested
by the
active board

2.9.10
CMCF
board
(source:
Restart
requeste
d by the
active
board)
(page
356)

9502771
12779571
12845107

Board reset
asked by
OMC

2.9.11
CMCF
(source:
Board
reset
asked by
OMC)
(page
356)

9502757
12779557
12845093

Restart
due to a
software
upgrade

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

334

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Source
wording

Source No.

S8000
Indoor
BCF

CBCF

S8000 Out
door
BCF

CBC
F

S800
2

S8003

S8006

Paragra
ph

9502758
12779558
12845094

Restart due
to hardware
watchdog

2.9.12
CMCF
board
(source:
Restart
due to
hardware
watchdo
g) (page
357)

9502759
12775095
12845095

Restart due
to double
bus fault

2.9.13
CMCF
boards
(source:
Restart
due to
double
bus faul
t) (page
357)

9502760
12779560
12845096

Reset for
new Lapd
parameters
CMCF

2.9.14
CMCF
boards
(source:
Reset
for new
Lapd pa
rameters
CMCF)
(page
357)

CMCF
CMCF phase 1
CMCF phase 2
9502761
12779561
12845097

Restart due
to Syn not
Locked

9502963
12779763
12845299

Statistic
report

9568240
12845040
12910576

Debug

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.9 Fault number: 1060 (S8000, S8002, S8003, and S8006 BTS)

Source
wording

Source No.

S8000
Indoor
BCF

CBCF

S8000 Out
door
BCF

CBC
F

S800
2

S8003

S8006

335

Paragra
ph

CMCF
CMCF phase 1
CMCF phase 2
9568241
12845041
12910577

ABIS PCM
statistics

2.9.15
CMCF
boards
(source:
ABIS
PCM st
atistics)
(page
358)

9568255
12845055
12910591

Soft

CSWM boards
4259842

Unknown
message
on ABIS
interface

4259872

Restart due
to reset by
BSC

4259873

Restart due
to reset by
reset button

4259874

Restart due
to power on

4259875

Restart due
to a too
long PCM
scanning

4259876

Restart
requested
by the
active board

4259877

Restart
due to a
software
upgrade

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

336

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Source No.

Source
wording

S8000
Indoor
BCF

CBCF

S8000 Out
door
BCF

CBC
F

S800
2

S8003

S8006

Paragra
ph

4259878

Restart due
to hardware
watchdog

2.9.16
CSWM
board
(source:
Restart
due to
hardware
watchdo
g) (page
358)

4259879

Restart due
to double
bus fault

2.9.17
CSWM
board
(source:
Restart
due to
double
bus faul
t) (page
359)

4325375

Soft

DACS climatic system


7864321

Dirty filter

7864322

DACS failed

DRX module
9437189

SPU fault

9437441

Restart due
to reset by
reset button

9437187
12582915
12976131

Loss of
PCM link

9437188
12582916
12976132

Loss of
GSM clock

DRX
eDRX
DRX ND3

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.9 Fault number: 1060 (S8000, S8002, S8003, and S8006 BTS)

Source No.

Source
wording

S8000
Indoor

S8000 Out
door

BCF

CBCF

BCF

CBC
F

337

S800
2

S8003

S8006

Paragra
ph

9437192
12582920
12976136

Incorrect Ab
is message

9437195
12582923
12976139

No flag on
FH bus

9437196
12582924
12976140

Frequency
collision on
FH bus

2.9.18
DRX or
eDRX
or DRX
-ND3 or
eDRX2
modules
(source:
Freque
ncy coll
ision on
FH bus)
(page
359)

9437207
12582935
12976151

FACCH
congestion

2.9.20
DRX or
eDRX
or DRX
ND3 or
eDRX2
modules
(source:
FACCH
congestio
n) (page
360)

9437208
12582936
12976152

LAPD
congestion

9437210
12582938
12976154

Underrun
AMNU-SPU

9437425
12583153
12976369

Post mort
em dump
zone 1

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

338

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Source No.

Source
wording

S8000
Indoor

S8000 Out
door

BCF

CBCF

BCF

CBC
F

S800
2

S8003

S8006

Paragra
ph

9437426
12583154
12976370

Post mort
em dump
zone 2

9437440
12583168
12976384

Restart due
to reset by
BSC

9437442
12583170
12976385

Restart due
to power on

9437443
12583171
12976385

Restart
requested
by the BCF

2.9.19
DRX or
eDRX
or DRX
-ND3 or
eDRX2
(source:
Restart
requeste
d by the
BCF)
(page
360)

9437444
12583172
12976386

Restart
due to the
timeout on
the OML
link with
BSC

9437445
12583173
12976387

Restart
due to the
timeout on
the OML
link with
BCF

9437446
12583174
12976388

Restart
due to a
software
upgrade

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.9 Fault number: 1060 (S8000, S8002, S8003, and S8006 BTS)

Source No.

Source
wording

S8000
Indoor

S8000 Out
door

BCF

CBCF

BCF

CBC
F

S800
2

S8003

S8006

339

Paragra
ph

9437447
12583175
13976389

Restart due
to hardware
watchdog

2.9.21
DRX or
eDRX
or DRX
ND3 or
eDRX2
modules
(source:
Reset
due to
hardware
watchdo
g) (page
361)

9437448
12583176
12976390

Restart due
to double
bus fault

2.9.13
CMCF
boards
(source:
Restart
due to
double
bus faul
t) (page
357)

9437449
12583177
12976391

Reset due
to loss of
lock

9437450
12583178
12976392

Restart due
to unknown
software
reset

9437451
12583179
12976393

Restart due
to a loss
of internal
PCM clock
sent by the
BCF

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

340

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Source No.

Source
wording

S8000
Indoor

S8000 Out
door

BCF

CBCF

BCF

CBC
F

S800
2

S8003

S8006

Paragra
ph

9437458
or
12583186
or
12976402

BCCH
config dump

2.9.23
DRX or
eDRX
or DRX
-ND3 or
eDRX2
modules
(source:
BCCH
config
dump)
(page
362)

9437474
or
12583202
or
12976418

SACCH
config dump

2.9.24
DRX or
eDRX or
DRX-N
D3 mod
ules or
eDRX2
(source:
SACCH
config
dump)
(page
363)

9437490
or
12583218
or
12976434

L1M config
dump

2.9.25
DRX or
eDRX
or DRX
-ND3 or
eDRX2
modules
(source:
L1M conf
ig dump)
(page
363)

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.9 Fault number: 1060 (S8000, S8002, S8003, and S8006 BTS)

Source No.

Source
wording

S8000
Indoor

S8000 Out
door

BCF

CBCF

BCF

CBC
F

S800
2

S8003

S8006

341

Paragra
ph

9437491
or
12583219
or
12976435

RSL anoma
ly

2.9.26
DRX or
eDRX or
eDRX2
or DR
X-ND3
modules
(source:
RSL an
omaly)
(page
363)

9502704
12648432
13041648

Debug

4456449

Major fault

4456450

Queue
overflow in
DSC

4456452

Queue OK

4456453

Channel_H
SCX

DSC boards

eDRX2
15204355

Loss of
PCM link

15204356

Loss of
GSM clock

15204360

Incorrect Ab
is message

15204363

No flag on
FH bus

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

342

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Source No.

Source
wording

S8000
Indoor
BCF

CBCF

S8000 Out
door
BCF

CBC
F

S800
2

S8003

S8006

Paragra
ph

15204364

Frequency
collision on
FH bus

2.9.18
DRX or
eDRX
or DRX
-ND3 or
eDRX2
modules
(source:
Freque
ncy coll
ision on
FH bus)
(page
359)

15204375

FACCH
congestion

2.9.20
DRX or
eDRX
or DRX
ND3 or
eDRX2
modules
(source:
FACCH
congestio
n) (page
360)

15204376

LAPD
congestion

15204378

Underrun
AMNU-SPU

15204593

Post mort
em dump
zone 1

15204594

Post mort
em dump
zone 2

15204610

Restart due
to power on

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.9 Fault number: 1060 (S8000, S8002, S8003, and S8006 BTS)

Source No.

Source
wording

S8000
Indoor
BCF

CBCF

S8000 Out
door
BCF

CBC
F

S800
2

S8003

15204611

Restart
requested
by the BCF

15204612

Restart
due to the
timeout on
the OML
link with
BSC

15204613

Restart
due to the
timeout on
the OML
link with
BCF

15204614

Restart
due to a
software
upgrade

15204615

Restart due
to hardware
watchdog

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

S8006

343

Paragra
ph
2.9.19
DRX or
eDRX
or DRX
-ND3 or
eDRX2
(source:
Restart
requeste
d by the
BCF)
(page
360)

2.9.16
CSWM
board
(source:
Restart
due to
hardware
watchdo
g) (page
358)

344

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Source No.

Source
wording

S8000
Indoor
BCF

CBCF

S8000 Out
door
BCF

CBC
F

S800
2

S8003

15204616

Restart due
to double
bus fault

15204617

Reset due
to loss of
lock

15204618

Restart due
to unknown
software
reset

15204619

Restart due
to a loss
of internal
PCM clock
sent by BCF

15204626

BCCH
config dump

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

S8006

Paragra
ph
2.9.17
CSWM
board
(source:
Restart
due to
double
bus faul
t) (page
359)

2.9.23
DRX or
eDRX
or DRX
-ND3 or
eDRX2
modules
(source:
BCCH
config
dump)
(page
362)

2.9 Fault number: 1060 (S8000, S8002, S8003, and S8006 BTS)

Source No.

Source
wording

S8000
Indoor
BCF

CBCF

S8000 Out
door
BCF

CBC
F

S800
2

S8003

S8006

345

Paragra
ph

15204642

SACCH
config dump

2.9.24
DRX or
eDRX or
DRX-N
D3 mod
ules or
eDRX2
(source:
SACCH
config
dump)
(page
363)

15204658

L1M config
dump

2.9.25
DRX or
eDRX
or DRX
-ND3 or
eDRX2
modules
(source:
L1M conf
ig dump)
(page
363)

15204659

RSL anoma
ly

2.9.26
DRX or
eDRX or
eDRX2
or DR
X-ND3
modules
(source:
RSL an
omaly)
(page
363)

GTW boards
4587522

FIFO-reset

Output Rx-splitter D
9764865

Over curren
t

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

346

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Source No.

Source
wording

S8000
Indoor
BCF

S8000 Out
door

CBCF

S800
2

S8003

S8006

Paragra
ph

CBC
F

BCF

Output Rx-splitter M
9699329

Over curren
t

PCM
6488065

PCM

Rectifiers
5242881

AC fault

5242882

DC fault

5242883

Over tempe
rature

5242884

External
battery level
1

5242885

PCU protect
ive

5242886

Battery on
discharges

2.9.65 T
x Filters
(source:
VSWR
level 2)
(page
384)

Tx Filters
7536642

VSWR level
2

Table 8
Fault number 1060 sources (IP)
S8000
Indoor

Source No.

Source wording

S8000
Outd
oor

S8
00
CB 2
BC CB BC
C
F CF F
F

S8
00
3

S8
00
6

Paragraph

IPM core
15728641

Restart due to
power on

2.9.27 IPM-USER core


(source: Restart due to
power-on) (page 364)

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.9 Fault number: 1060 (S8000, S8002, S8003, and S8006 BTS)

S8000
Indoor

Source No.

Source wording

S8000
Outd
oor

S8
00
CB 2
BC CB BC
C
F CF F
F

S8
00
3

S8
00
6

347

Paragraph

15728642

Restart due to
reset by button

2.9.28 IPM-USER core


(source: Restart due
to reset by button)
(page 364)

15728643

Restart due to
software upgrade

2.9.29 IPM-USER core


(source: Restart due
to software upgrade)
(page 365)

15728644

Restart due
to hardware
watchdog

2.9.30 IPM-USER core


(source: Restart due to
hardware watchdog)
(page 365)

15728647

IBOS authenticati
on has failed

2.9.31 IPM-USER
core (source: IBOS
authentication has failed)
(page 366)

15728648

No TCP connecti
on can be set up
with IGM

2.9.32 IPM-USER
core (source: No TCP
connection can be set up
with IGM) (page 366)

15728649

Reset requested
by IGM with no
Ethernet switch
reset

2.9.33 IPM-USER core


(source: Reset requested
by IGM with no Ethernet
switch reset) (page 367)

15728650

Reset requested
by IGM with
Ethernet switch
reset

2.9.34 IPM-USER core


(source: Reset requested
by IGM with Ethernet
switch reset) (page 367)

15728651

Reset requested
by IBOS with
BIST execution
and Ethernet
switch reset

2.9.35 IPM-USER core


(source: Reset requested
by IBOS with BIST
execution and Ethernet
switch reset) (page 368)

15728652

Reset requested
by IBOS with no
BIST execution
and Ethernet
switch reset

2.9.36 IPM-USER core


(source: Reset requested
by IBOS with no BIST
execution and Ethernet
switch reset) (page 368)

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

348

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

S8000
Indoor

S8000
Outd
oor

S8
00
CB 2
BC CB BC
C
F CF F
F

S8
00
3

S8
00
6

Paragraph

Source No.

Source wording

15728653

Reset requested
by IBOS with
BIST execution
and no Ethernet
switch reset

2.9.37 IPM-USER core


(source: Reset requested
by IBOS with BIST
execution and no Ethernet
switch reset) (page 369)

15728654

Reset requested
by IBOS with no
BIST execution
nor Ethernet
switch reset

2.9.38 IPM-USER core


(source: Reset requested
by IBOS with no BIST
execution nor Ethernet
switch reset) (page 370)

15728655

Restart after TM
L commissioning

2.9.39 IPM-USER core


(source: Restart after
TML commissioning)
(page 370)

15728656

Connection with
IGM has been
lost (no status
received for
7 keep-alive
periods).

2.9.40 IPM-USER core


(source: Connection
with IGM has been lost
(no status received for
7 keep-alive periods))
(page 371)

15728659

No response to
DHCP requests
for 15 minutes

2.9.41 IPM-USER core


(source: No response to
DHCP requests for 15
minutes) (page 371)

15728660

No response to
DNS requests for
15 minutes

2.9.42 IPM-USER core


(source: No response
to DNS requests for 15
minutes) (page 372)

15728673

Debug

2.9.43 IPM-USER
core (source: Debug)
(page 372)

15728674

Soft

2.9.44 IPM-USER core


(source: Soft) (page 373)

RIPM-USER core
15794177

Restart due to
power on

2.9.45 RIPM-USER core


(source: Restart due to
power-on) (page 373)

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.9 Fault number: 1060 (S8000, S8002, S8003, and S8006 BTS)

S8000
Indoor

Source No.

Source wording

S8000
Outd
oor

S8
00
CB 2
BC CB BC
C
F CF F
F

S8
00
3

S8
00
6

349

Paragraph

15794178

Restart due to
reset by button

2.9.46 RIPM-USER
core (source: Restart
due to reset by button)
(page 374)

15794179

Restart due to
software upgrade

2.9.47 RIPM-USER core


(source: Restart due
to software upgrade)
(page 374)

15794180

Restart due
to hardware
watchdog

2.9.48 RIPM-USER core


(source: Restart due to
hardware watchdog)
(page 375)

15794183

IBOS authenticati
on has failed

2.9.49 RIPM-USER
core (source: IBOS
authentication has failed)
(page 375)

15794184

No TCP connecti
on can be set up
with IGM

2.9.50 RIPM-USER
core (source: No TCP
connection can be set up
with IGM) (page 376)

15794185

Reset requested
by IGM with no
Ethernet switch
reset

2.9.51 RIPM-USER core


(source: Reset requested
by IGM with no Ethernet
switch reset) (page 376)

15794186

Reset requested
by IGM with
Ethernet switch
reset

2.9.52 RIPM-USER core


(source: Reset requested
by IGM with Ethernet
switch reset) (page 377)

15794187

Reset requested
by IBOS with
BIST execution
and Ethernet
switch reset

2.9.53 RIPM-USER core


(source: Reset requested
by IBOS with BIST
execution and Ethernet
switch reset) (page 377)

15794188

Reset requested
by IBOS with no
BIST execution
and Ethernet
switch reset

2.9.54 RIPM-USER core


(source: Reset requested
by IBOS with no BIST
execution and Ethernet
switch reset) (page 378)

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

350

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

S8000
Indoor

S8000
Outd
oor

S8
00
CB 2
BC CB BC
C
F CF F
F

S8
00
3

S8
00
6

Paragraph

Source No.

Source wording

15794189

Reset requested
by IBOS with
BIST execution
and no Ethernet
switch reset

2.9.55 RIPM-USER
core (source: Reset
requested by IBOS with
BIST execution and no
Ethernet switch reset)
(page 378)

15794190

Reset requested
by IBOS with no
BIST execution
nor Ethernet
switch reset

2.9.56 RIPM-USER core


(source: Reset requested
by IBOS with no BIST
execution nor Ethernet
switch reset) (page 379)

15794191

Restart after TM
L commissioning

2.9.57 RIPM-USER core


(source: Restart after
TML commissioning)
(page 379)

15794192

Connection with
IGM has been
lost (no status
received for
7 keep_alive
periods).

2.9.58 RIPM-USER core


(source: Connection
with IGM has been lost
(no status received for
7 keep-alive periods))
(page 380)

15794195

No response to
DHCP requests
for 15 minutes

2.9.59 RIPM-USER core


(source: No response to
DHCP requests for 15
minutes) (page 380)

15794196

No response to
DNS requests for
15 minutes

2.9.60 RIPM-USER core


(source: No response
to DNS requests for 15
minutes) (page 381)

15794209

Debug

2.9.61 RIPM-USER
core (source: Debug)
(page 381)

15794210

Soft

2.9.62 RIPM-USER core


(source: Soft) (page 382)

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.9 Fault number: 1060 (S8000, S8002, S8003, and S8006 BTS)

S8000
Indoor

S8000
Outd
oor

S8
00
CB 2
BC CB BC
C
F CF F
F

S8
00
3

S8
00
6

351

Paragraph

Source No.

Source wording

15794193

Reset requested
by active with
BIST execution

2.9.63 RIPM-USER core


(source: Reset requested
by active with BIST
execution) (page 383)

15794194

Reset requested
by active with no
BIST execution

2.9.64 RIPM-USER core


(source: Reset requested
by active with no BIST
execution) (page 383)

2.9.1 BRC (source: Manual switch on battery power)


Fault number 1060

Abis event reporting a transient default

Equipment :

BRC

Source :

(6553601) Manual switch on battery power

BTS model :

S8000 CBCF Outdoor + S8002

FAULT ANALYSIS
This notification indicates that the BTS has been manually (using OMC-R
command) switched from main power to battery.

2.9.2 BRC (source: Automatic switch on battery power)


Fault number 1060

Abis event reporting a transient default

Equipment:

BRC

Source:

(6553602) Automatic switch on battery power

BTS model:

S8000 CBCF Outdoor + S8002

FAULT ANALYSIS
This notification indicates that the BTS has automatically switched from
main power to battery.

2.9.3 BRC (source: Manual switch on main power)


Fault number 1060

Abis event reporting a transient default

Equipment:

BRC

Source:

(6553603) Manual switch on main power

BTS model:

S8000 CBCF Outdoor + S8002

FAULT ANALYSIS
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

352

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

This notification indicates that the BTS has been manually switched from
battery to main power.

2.9.4 BRC (source: Automatic switch on main power)


Fault number 1060

Abis event reporting a transient default

Equipment:

BRC

Source:

(6553604) Automatic switch on main power

BTS model:

S8000 CBCF Outdoor + S8002

FAULT ANALYSIS
This notification indicates that the BTS has been automatically switched
from battery to main power.

2.9.5 Cavity (source: Cavity parked after tuning fault (min not found))
Fault number 1060

Abis event reporting a hardware fault

Equipment:

cavity

Source:

(8388610) Cavity parked after tuning fault (min not


found)

BTS model:

S8000 Indoor

FAULT ANALYSIS
This alarm indicates that the cavity is no longer parked on its configuration
frequency.

REACTION OF THE SYSTEM


BSC defense The BSC unconfigures the transceiverEquipment
object concerned and reconfigures the transceiver object on another
transceiverEquipment object (if the TDMA is priority).

CAUTION
Service reduction
The service is reduced.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.9 Fault number: 1060 (S8000, S8002, S8003, and S8006 BTS)

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.

353

If a fault number 1054 (loss of layer 2) has appeared,


refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 5.

Check that the alarm on the cavity equipment is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "cavity" equipment is "failed", the fault is


confirmed. Go to step 3.

If the state of the "cavity" equipment is "working", the fault is


not confirmed. Go to step 5.

Maintenance at the OMC-R

Lock the transceiverEquipment object in order to trigger a new


tuning.

Unlock the transceiverEquipment object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

354

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the problem has disappeared, go to step 5.


If the problem persists after several attempts, an on-site
intervention is necessary to locate the problem.

The procedure is complete.


--End--

2.9.6 Cavity (source: Nack answer from cavity)


Fault number 1060

Abis event reporting a transient default

Equipment:

cavity

Source:

(8388612) Nack answer from cavity

BTS model:

S8000 Indoor

FAULT ANALYSIS
This alarm indicates that there was a NACK response on the slave.

REACTION OF THE SYSTEM


BSC defense None
None.
Impact on the service

None

TROUBLESHOOTING

Set the administrativeState of the transceiverEquipment object to


"locked".

Set the administrativeState of the transceiverEquipment object to


"unlocked".

2.9.7 Cavity (source: Cavity parked after tuning fault (power too low))
Fault number 1060

Abis event reporting a hardware fault

Equipment:

cavity

Source:

(8388613) Cavity parked after tuning fault (power


too low)

BTS model:

S8000 Indoor

REACTION OF THE SYSTEM


BSC defense The BSC unconfigures the transceiverEquipment object
concerned.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.9 Fault number: 1060 (S8000, S8002, S8003, and S8006 BTS)

Impact on the service

355

One TRX becomes unavailable.

CAUTION
Service reduction
The service is reduced.

2.9.8 Cavity (source: Cavity parked after tuning fault (tuning detector))
Fault number 1060

Abis event reporting a hardware fault

Equipment:

cavity

Source:

(8388614) Cavity parked after tuning fault (tuning


detector)

BTS model:

S8000 Indoor

REACTION OF THE SYSTEM


BSC defense The BSC unconfigures the transceiverEquipment object
concerned.
Impact on the service

One TRX becomes unavailable.

CAUTION
Service reduction
The service is reduced.

2.9.9 CMCF board (source: Unknown message)


Fault number 1060

Abis event reporting a transient default

Equipment:

CMCF or CMCF phase 1 or CMCF phase 2

Source:

(9502722 or 12779522 or 12845058) Unknown


message

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
This alarm indicates an unknown Abis message.
REACTION OF THE SYSTEM
BSC defense
None.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

356

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Impact on the service


None.

2.9.10 CMCF board (source: Restart requested by the active board)


Fault number 1060

Abis event reporting a transient default

Equipment:

CMCF or CMCF phase 1 or CMCF phase 2

Source:

(9502756, 12779556, 12845092) Restart requested by the active


board

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This alarm indicates a reset of the passive CMCF requested by the active
CMCF.
IMPACT ON THE SERVICE
No impact on the service.
TROUBLESHOOTING
No maintenance action is required.

2.9.11 CMCF (source: Board reset asked by OMC)


Fault number 1060

Abis event reporting a transient default

Equipment:

CMCF or CMCF phase 1 or CMCF phase 2

Source:

(9502771, 12779571, 12845107) Board reset asked by OMC

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This alarm indicates a board reset asked by the OMC-R, for the active
CMCF.
No maintenance action is required.
IMPACT ON THE SERVICE
The BTS behavior is identical to a hot switchover:

There is no impact on the traffic and on the configuration.


The passive CMCF becomes active.
The BTS sends a restart event of the reset CMCF.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.9 Fault number: 1060 (S8000, S8002, S8003, and S8006 BTS)

357

TROUBLESHOOTING
No maintenance action is required.

2.9.12 CMCF board (source: Restart due to hardware watchdog)


Fault number 1060

Abis event reporting a transient default

Equipment:

CMCF or CMCF phase 1 or CMCF phase 2

Source:

(9502758 or 12779558 or 12845094) Restart due to


hardware watchdog

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
This alarm indicates a restart of the CMCF boards by a hardware
watchdog.
No maintenance action is required.

2.9.13 CMCF boards (source: Restart due to double bus fault)


Fault number 1060

Abis event reporting a transient default

Equipment:

CMCF or CMCF phase 1 or CMCF phase 2

Source:

(9502759 or 12779559 or 12845095) Restart due


to double bus fault

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
This alarm indicates a restart of the CMCF boards due to a double bus
fault.
TROUBLESHOOTING
If the fault occurs sporadically, no maintenance action is required.
If the fault is repetitive, replace the faulty CMCF. Refer to 411-9001-048
(Nortel GSM BTS S8000/S8003 Troubleshooting).

2.9.14 CMCF boards (source: Reset for new Lapd parameters CMCF)
Fault number 1060

Abis event reporting a transient default

Equipment:

CMCF or CMCF phase 1 or CMCF phase 2

Source:

(9502760) Reset for new Lapd parameters CMCF

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

358

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Source:

(12779560) Reset for new Lapd parameters CMCF


Ph1

Source:

(12845096) Reset for new Lapd parameters CMCF


Ph2

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
This alarm indicates a BTS restart to take into account new Lapd
parameter values from the BSC, so as to use a satellite configuration
(satellite Abis interface).
Even if BSC Lapd parameters are not consistent with BTS values, the
Lapd link can be established and the Status Request can be sent to the
BTS.
When receiving the Status Request, in case of BSC / BTS inconsistency,
the BTS writes the new values in its memory and then restarts to take into
account this new set of parameters.
TROUBLESHOOTING
No maintenance action is required.

2.9.15 CMCF boards (source: ABIS PCM statistics)


Fault number 1060

Abis event reporting a transient default

Equipment:

CMCF

Source:

(9568241 or 12845041 or 12910577) ABIS PCM


statistics

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
This notification appears when the command "Display data information" is
performed on the object "btsSiteManager" at the OMC-R.

2.9.16 CSWM board (source: Restart due to hardware watchdog)


Fault number 1060

Abis event reporting a transient default

Equipment:

CSWM

Source:

(4259878) Restart due to hardware watchdog

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8006

FAULT ANALYSIS

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.9 Fault number: 1060 (S8000, S8002, S8003, and S8006 BTS)

359

This alarm indicates a restart of the CSWM boards by a hardware


watchdog.
No maintenance action is required.

2.9.17 CSWM board (source: Restart due to double bus fault)


Fault number 1060

Abis event reporting a transient default

Equipment:

CSWM

Source:

(4259879) Restart due to double bus fault

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8006

FAULT ANALYSIS
This alarm indicates a restart of the CSWM board due to a double bus
fault.
TROUBLESHOOTING
If the fault occurs sporadically, no maintenance action is required.
If the fault is repetitive, replace the faulty CSWM. Refer to 411-9001-048
(Nortel GSM BTS S8000/S8003 Troubleshooting).

2.9.18 DRX or eDRX or DRX-ND3 or eDRX2 modules (source:


Frequency collision on FH bus)
Fault number 1060

Abis event reporting a transient default

Equipment:

DRX or eDRX or DRX-ND3 or eDRX2

Source:

9437196 or 12582924 or 12976140 or 15204363


Frequency collision on FH bus

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
This alarm indicates that a frequency collision has been encountered on
the FH bus, due to a frequency hopping configuration error.
REACTION OF THE SYSTEM
BSC defense
None.
Impact on the service

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

360

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

CAUTION
Service quality
The phonic quality is lost.

TROUBLESHOOTING
Check the cell and the frequency hopping laws (the configuration of
Frequency Hopping Laws, or the TDMA configuration if there is not any
hopping).

2.9.19 DRX or eDRX or DRX-ND3 or eDRX2 (source: Restart requested


by the BCF)
Fault number 1060

Abis event reporting a transient default

Equipment:

DRX or eDRX or DRX-ND3 or eDRX2

Source:

(9437443, 12976387, 12583171, 15204611) Restart requested


by the BCF

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This alarm indicates a reset of the DRX requested by the BCF. The
BTS informs the BSC of the DRX loss. The DRX is declared faulty and
reconfigured.
REACTION OF THE SYSTEM
BSC defense
None.
Impact on the service
The DRX is declared faulty and reconfigured. A restart event of the DRX is
sent to the BSC.
TROUBLESHOOTING
No maintenance action is required.

2.9.20 DRX or eDRX or DRX ND3 or eDRX2 modules (source: FACCH


congestion)
Fault number 1060
Equipment:

Abis event reporting a transient default


DRX or eDRX or DRX ND3 or eDRX2

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.9 Fault number: 1060 (S8000, S8002, S8003, and S8006 BTS)

Source:

(9437207 or 12582935 or 12976151 or


15204375) FACCH congestion

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 +


S8003 + S8006

361

FAULT ANALYSIS
FACCH "Fast associated Control Channel" is one of the dedicated control
channels.
It is associated to a TCH channel and is used to exchange fast signaling
messages with the MS.
In compliance with GSM Rec. 5.03, a FACCH for TCH/FR is coded
over 8 bursts and for TCH/HR over 6 bursts. This imposes a maximum
transmission rate for FACCH messages, above which the messages are
queued. The queuing mechanism allows for up to 3 FACCH messages
per channel (per sub-channel for TCH/HR) to be waiting for transmission.
When this limit is exceeded, the BTS sends the notification FACCH
Congestion and the waiting messages are discarded. A Timer mechanism
ensures that the dropped messages are repeated.
FACCH congestion is usually linked to handover activity (for speed and
priority reasons, the FACCH channel is especially used for handover
process). Increased handover activity equals a greater risk of FACCH
congestion.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service The only impact is that handovers may be
delayed by up to 160 ms, the time between 2 repetitions of the FACCH
message.
There will no impact on the counters and no dropped calls, nor service
denied.

TROUBLESHOOTING
No maintenance action is required.

2.9.21 DRX or eDRX or DRX ND3 or eDRX2 modules (source: Reset


due to hardware watchdog)
Fault number 1060
Equipment:

Abis event reporting a transient default


DRX or eDRX or DRX ND3 or eDRX2

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

362

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Source:

9437447 or 12583175 or 12976389 or


15204615 : restart due to hardware watchdog

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 +


S8003 + S8006

FAULT ANALYSIS
This alarm indicates a restart of the DRX by a hardware watchdog.
No maintenance action is required.

2.9.22 DRX or eDRX or DRX ND3 or eDRX2 modules (source: Restart


due to double bus fault)
Fault number 1060

Abis event reporting a transient default

Equipment:

DRX or eDRX or DRX ND3 or eDRX2

Source:

9437448 or 12583176 or 12976390 or


15204616: Restart due to double bus fault

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 +


S8003 + S8006

FAULT ANALYSIS
This alarm indicates a restart of the DRX due to a double bus fault.
TROUBLESHOOTING
If the fault occurs sporadically, no maintenance action is required.
If the fault is repetitive, replace the faulty DRX. Refer to 411-9001-048
(Nortel GSM BTS S8000/S8003 Troubleshooting).

2.9.23 DRX or eDRX or DRX-ND3 or eDRX2 modules (source: BCCH


config dump)
Fault number 1060

Abis event reporting a transient default

Equipment:

DRX or eDRX or DRX-ND3 or eDRX2

Source:

9437458 or 12583186 or 12976402 or


15204626 BCCH config dump

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 +


S8003 + S8006

FAULT ANALYSIS
An anomaly has been detected in either a first or second BCCH
configuration. This transient event contains details of the anomaly.
TROUBLESHOOTING

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.9 Fault number: 1060 (S8000, S8002, S8003, and S8006 BTS)

363

No maintenance action is required.

2.9.24 DRX or eDRX or DRX-ND3 modules or eDRX2 (source: SACCH


config dump)
Fault number 1060

Abis event reporting a transient default

Equipment:

DRX or eDRX or DRX-ND3 or eDRX2

Source:

9437474 or 12583202 or 12976418 or 15204642


SACCH config dump

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
An anomaly has been detected in either a first or second SACCH
configuration. This transient event contains details of the anomaly.
TROUBLESHOOTING
No maintenance action is required.

2.9.25 DRX or eDRX or DRX-ND3 or eDRX2 modules (source: L1M


config dump)
Fault number 1060

Abis event reporting a transient default

Equipment:

DRX or eDRX or DRX-ND3 or eDRX2

Source:

9437490 or 12583218 or 12976434 or


15204658 L1M config dump

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 +


S8003 + S8006

FAULT ANALYSIS
An anomaly has been detected in either a first or second L1M
configuration. This transient event contains details of the anomaly.
TROUBLESHOOTING
No maintenance action is required.

2.9.26 DRX or eDRX or eDRX2 or DRX-ND3 modules (source: RSL


anomaly)
Fault number 1060
Equipment:

Abis event reporting a transient default


DRX or eDRX or DRX-ND3 or eDRX2

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

364

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Source:

9437491 or 12583219 or 12976435 or


15204659 RSL anomaly

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 +


S8003 + S8006

FAULT ANALYSIS
A non critical anomaly has been detected on a communication. This
transient event contains details of the anomaly.
TROUBLESHOOTING
No maintenance action is required.

2.9.27 IPM-USER core (source: Restart due to power-on)


Fault number 1060 Abis event reporting a transient default
Equipment:

IPM-USER core

Source:

(15728641) Restart due to power-on

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm indicates a restart of the IPM-USER due to a power-on.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
None.

TROUBLESHOOTING
No maintenance action is required.

2.9.28 IPM-USER core (source: Restart due to reset by button)


Fault number 1060 Abis event reporting a transient default
Equipment:

IPM-USER core

Source:

(15728642) Restart due to reset by button

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm indicates an IPM-USER restart due to reset by button.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.9 Fault number: 1060 (S8000, S8002, S8003, and S8006 BTS)

365

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
None.

TROUBLESHOOTING
No maintenance action is required.

2.9.29 IPM-USER core (source: Restart due to software upgrade)


Fault number 1060 Abis event reporting a transient default
Equipment:

IPM-USER core

Source:

(15728643) Restart due to software upgrade

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm indicates an IPM-USER restart due to software upgrade (new
software version activation).

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
None.

TROUBLESHOOTING
No maintenance action is required.

2.9.30 IPM-USER core (source: Restart due to hardware watchdog)


Fault number 1060 Abis event reporting a transient default
Equipment:

IPM-USER core

Source:

(15728644 Restart due to hardware watchdog

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm indicates an IPM-USER restart due to hardware watchdog.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

366

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
None.

TROUBLESHOOTING
No maintenance action is required.

2.9.31 IPM-USER core (source: IBOS authentication has failed)


Fault number 1060 Abis event reporting a transient default
Equipment:

IPM-USER core

Source:

(15728647) IBOS authentication has failed

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm indicates that the IPM-USER does not succeed to connect and
authenticate to any IBOS.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
None.

TROUBLESHOOTING
No maintenance action is required.

2.9.32 IPM-USER core (source: No TCP connection can be set up with


IGM)
Fault number 1060 Abis event reporting a transient default
Equipment:

IPM-USER core

Source:

(15728648) No TCP connection can be set up with IGM

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm indicates that no TCP connection can be set up with IGM.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.9 Fault number: 1060 (S8000, S8002, S8003, and S8006 BTS)

367

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
None.

TROUBLESHOOTING
No maintenance action is required.

2.9.33 IPM-USER core (source: Reset requested by IGM with no


Ethernet switch reset)
Fault number 1060 Abis event reporting a transient default
Equipment:

IPM-USER core

Source:

(15728649) Reset requested by IGM with no Ethernet switch reset

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm indicates that a reset is requested by the IGM, with no Ethernet
switch reset.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
None.

TROUBLESHOOTING
No maintenance action is required.

2.9.34 IPM-USER core (source: Reset requested by IGM with Ethernet


switch reset)
Fault number 1060 Abis event reporting a transient default
Equipment:

IPM-USER core

Source:

(15728650) Reset requested by IGM with Ethernet switch reset

BTS model:

S8000 Outdoor + S8000 Indoor

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

368

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

FAULT ANALYSIS
This alarm indicates that a reset is requested by the IGM, with an Ethernet
switch reset.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
None.

TROUBLESHOOTING
No maintenance action is required.

2.9.35 IPM-USER core (source: Reset requested by IBOS with BIST


execution and Ethernet switch reset)
Fault number 1060 Abis event reporting a transient default
Equipment:

IPM-USER core

Source:

(15728651) Reset requested by IBOS with BIST execution and Ethernet switch
reset

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm indicates that the active IPM board has been reset with a BIST
execution. The IBOS has requested an Ethernet switch reset.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
None.

TROUBLESHOOTING
No maintenance action is required.

2.9.36 IPM-USER core (source: Reset requested by IBOS with no BIST


execution and Ethernet switch reset)
Fault number 1060 Abis event reporting a transient default
Equipment:

IPM-USER core

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.9 Fault number: 1060 (S8000, S8002, S8003, and S8006 BTS)

Source:

(157286512) Reset requested by IBOS with no BIST execution and Ethernet


switch reset

BTS model:

S8000 Outdoor + S8000 Indoor

369

FAULT ANALYSIS
This alarm indicates that the active IPM board has been reset without a
BIST execution. The IBOS has requested an Ethernet switch reset.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
None.

TROUBLESHOOTING
No maintenance action is required.

2.9.37 IPM-USER core (source: Reset requested by IBOS with BIST


execution and no Ethernet switch reset)
Fault number 1060 Abis event reporting a transient default
Equipment:

IPM-USER core

Source:

(157286513) Reset requested by IBOS with BIST execution and no Ethernet


switch reset

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm indicates that the active IPM board has been reset with a BIST
execution. The IBOS has not requested an Ethernet switch reset.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
None.

TROUBLESHOOTING
No maintenance action is required.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

370

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

2.9.38 IPM-USER core (source: Reset requested by IBOS with no BIST


execution nor Ethernet switch reset)
Fault number 1060 Abis event reporting a transient default
Equipment:

IPM-USER core

Source:

(157286514) Reset requested by IBOS with no BIST execution nor Ethernet


switch reset

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm indicates that the active IPM board has been reset without a
BIST execution. The IBOS has not requested an Ethernet switch reset.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
None.

TROUBLESHOOTING
No maintenance action is required.

2.9.39 IPM-USER core (source: Restart after TML commissioning)


Fault number 1060 Abis event reporting a transient default
Equipment:

IPM-USER core

Source:

(157286515) Restart after TML commissioning

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm indicates an IPM-USER restart by the TML, after
commissioning.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
None.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.9 Fault number: 1060 (S8000, S8002, S8003, and S8006 BTS)

371

TROUBLESHOOTING
No maintenance action is required.

2.9.40 IPM-USER core (source: Connection with IGM has been lost (no
status received for 7 keep-alive periods))
Fault number 1060 Abis event reporting a transient default
Equipment:

IPM-USER core

Source:

(157286516) Connection with IGM has been lost (no status received for 7
keep-alive periods)

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm indicates that the connection with IGM has been lost (no status
received for 7 keep-alive periods).

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
None.

TROUBLESHOOTING
No maintenance action is required.

2.9.41 IPM-USER core (source: No response to DHCP requests for 15


minutes)
Fault number 1060 Abis event reporting a transient default
Equipment:

IPM-USER core

Source:

(15728659) No response to DHCP requests for 15 minutes

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm indicates no response to DHCP requests for 15 minutes.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

372

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

None.

TROUBLESHOOTING
No maintenance action is required.

2.9.42 IPM-USER core (source: No response to DNS requests for 15


minutes)
Fault number 1060 Abis event reporting a transient default
Equipment:

IPM-USER core

Source:

(15728660) No response to DNS requests for 15 minutes

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm indicates no response to DNS requests for 15 minutes.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
None.

TROUBLESHOOTING
No maintenance action is required.

2.9.43 IPM-USER core (source: Debug)


Fault number 1060 Abis event reporting a transient default
Equipment:

IPM-USER core

Source:

(15728673) Debug

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm indicates that a message sent by the IBOS or IPG is not
acknowledged by the IPM-USER.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.9 Fault number: 1060 (S8000, S8002, S8003, and S8006 BTS)

None.

TROUBLESHOOTING
No maintenance action is required.

2.9.44 IPM-USER core (source: Soft)


Fault number 1060 Abis event reporting a transient default
Equipment:

IPM-USER core

Source:

(15728674) Soft

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm indicates that a trap occurs. The IPM-USER sends the
post-mortem dump zone to the IBOS.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
None.

TROUBLESHOOTING
No maintenance action is required.

2.9.45 RIPM-USER core (source: Restart due to power-on)


Fault number 1060 Abis event reporting a transient default
Equipment:

RIPM-USER core

Source:

(15794177) Restart due to power-on

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm indicates a restart of the RIPM-USER due to a power-on.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

373

374

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

None.

TROUBLESHOOTING
No maintenance action is required.

2.9.46 RIPM-USER core (source: Restart due to reset by button)


Fault number 1060 Abis event reporting a transient default
Equipment:

RIPM-USER core

Source:

(15794178) Restart due to reset by button

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm indicates an RIPM-USER restart due to a reset by button.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
None.

TROUBLESHOOTING
No maintenance action is required.

2.9.47 RIPM-USER core (source: Restart due to software upgrade)


Fault number 1060 Abis event reporting a transient default
Equipment:

RIPM-USER core

Source:

(15794179) Restart due to software upgrade

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm indicates an RIPM-USER core restart due to software upgrade
(new software version activation).

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.9 Fault number: 1060 (S8000, S8002, S8003, and S8006 BTS)

None.

TROUBLESHOOTING
No maintenance action is required.

2.9.48 RIPM-USER core (source: Restart due to hardware watchdog)


Fault number 1060 Abis event reporting a transient default
Equipment:

RIPM-USER core

Source:

(15794180) Restart due to hardware watchdog

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm indicates an RIPM-USER restart due to hardware watchdog.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
None.

TROUBLESHOOTING
No maintenance action is required.

2.9.49 RIPM-USER core (source: IBOS authentication has failed)


Fault number 1060 Abis event reporting a transient default
Equipment:

RIPM-USER core

Source:

(15794183) IBOS authentication has failed

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm indicates that the RIPM-USER core does not succeed to
connect and authenticate to any IBOS.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

375

376

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

None.

TROUBLESHOOTING
No maintenance action is required.

2.9.50 RIPM-USER core (source: No TCP connection can be set up with


IGM)
Fault number 1060 Abis event reporting a transient default
Equipment:

RIPM-USER core

Source:

(15794184) No TCP connection can be set up with IGM

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm indicates that no TCP connection can be set up with the IGM.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
None.

TROUBLESHOOTING
No maintenance action is required.

2.9.51 RIPM-USER core (source: Reset requested by IGM with no


Ethernet switch reset)
Fault number 1060 Abis event reporting a transient default
Equipment:

RIPM-USER core

Source:

(15794185) Reset requested by IGM with no Ethernet switch reset

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm indicates that a reset is requested by the IGM, with no Ethernet
switch reset.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.9 Fault number: 1060 (S8000, S8002, S8003, and S8006 BTS)

377

None.

TROUBLESHOOTING
No maintenance action is required.

2.9.52 RIPM-USER core (source: Reset requested by IGM with Ethernet


switch reset)
Fault number 1060 Abis event reporting a transient default
Equipment:

RIPM-USER core

Source:

(15794186) Reset requested by IGM with Ethernet switch reset

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm indicates that a reset is requested by the IGM, with an Ethernet
switch reset.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
None.

TROUBLESHOOTING
No maintenance action is required.

2.9.53 RIPM-USER core (source: Reset requested by IBOS with BIST


execution and Ethernet switch reset)
Fault number 1060 Abis event reporting a transient default
Equipment:

RIPM-USER core

Source:

(15794187) Reset requested by IBOS with BIST execution and Ethernet switch
reset

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm indicates an RIPM-USER core restart with a BIST execution.
The IBOS has requested an Ethernet switch reset.

REACTION OF THE SYSTEM


BSC defense
None.
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

378

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Impact on the service


None.

TROUBLESHOOTING
No maintenance action is required.

2.9.54 RIPM-USER core (source: Reset requested by IBOS with no BIST


execution and Ethernet switch reset)
Fault number 1060 Abis event reporting a transient default
Equipment:

RIPM-USER core

Source:

(15794188) Reset requested by IBOS with no BIST execution and Ethernet


switch reset

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm indicates an RIPM-USER core restart without a BIST execution.
The IBOS has requested an Ethernet switch reset.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
None.

TROUBLESHOOTING
No maintenance action is required.

2.9.55 RIPM-USER core (source: Reset requested by IBOS with BIST


execution and no Ethernet switch reset)
Fault number 1060 Abis event reporting a transient default
Equipment:

IPM

Source:

(15794189) Reset requested by IBOS with BIST execution and no Ethernet


switch reset

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm indicates an RIPM-USER core restart with a BIST execution.
The IBOS has not requested an Ethernet switch reset.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.9 Fault number: 1060 (S8000, S8002, S8003, and S8006 BTS)

379

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
None.

TROUBLESHOOTING
No maintenance action is required.

2.9.56 RIPM-USER core (source: Reset requested by IBOS with no BIST


execution nor Ethernet switch reset)
Fault number 1060 Abis event reporting a transient default
Equipment:

RIPM-USER core

Source:

(15794190) Reset requested by IBOS with no BIST execution nor Ethernet


switch reset

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm indicates that the active IPM-USER board has been reset
without a BIST execution. The IBOS has not requested an Ethernet switch
reset.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
None.

TROUBLESHOOTING
No maintenance action is required.

2.9.57 RIPM-USER core (source: Restart after TML commissioning)


Fault number 1060 Abis event reporting a transient default
Equipment:

RIPM-USER core

Source:

(15794191) Restart after TML commissioning

BTS model:

S8000 Outdoor + S8000 Indoor

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

380

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

FAULT ANALYSIS
This alarm indicates an RIPM-USER restart by the TML, after
commissioning.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
None.

TROUBLESHOOTING
No maintenance action is required.

2.9.58 RIPM-USER core (source: Connection with IGM has been lost
(no status received for 7 keep-alive periods))
Fault number 1060 Abis event reporting a transient default
Equipment:

RIPM-USER core

Source:

(15794192) Connection with IGM has been lost (no status received for 7
keep-alive periods)

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm indicates that the connection with IGM has been lost (no status
received for 7 keep-alive periods).

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
None.

TROUBLESHOOTING
No maintenance action is required.

2.9.59 RIPM-USER core (source: No response to DHCP requests for


15 minutes)
Fault number 1060 Abis event reporting a transient default
Equipment:

RIPM-USER core

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.9 Fault number: 1060 (S8000, S8002, S8003, and S8006 BTS)

Source:

(15794195) No response to DHCP requests for 15 minutes

BTS model:

S8000 Outdoor + S8000 Indoor

381

FAULT ANALYSIS
This alarm indicates no response to DHCP requests for 15 minutes.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
None.

TROUBLESHOOTING
No maintenance action is required.

2.9.60 RIPM-USER core (source: No response to DNS requests for 15


minutes)
Fault number 1060 Abis event reporting a transient default
Equipment:

RIPM-USER core

Source:

(15794196) No response to DNS requests for 15 minutes

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm indicates no response to DNS requests for 15 minutes.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
None.

TROUBLESHOOTING
No maintenance action is required.

2.9.61 RIPM-USER core (source: Debug)


Fault number 1060 Abis event reporting a transient default
Equipment:

RIPM-USER core

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

382

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Source:

(15794209) Debug

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm indicates that a message sent by the IBOS or IPG is not
acknowledged by the RIPM-USER.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
None.

TROUBLESHOOTING
No maintenance action is required.

2.9.62 RIPM-USER core (source: Soft)


Fault number 1060 Abis event reporting a transient default
Equipment:

RIPM-USER core

Source:

(15794210) Soft

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm indicates that a trap occurs. The RIPM-USER sends the
post-mortem dump zone to the IBOS.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
None.

TROUBLESHOOTING
No maintenance action is required.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.9 Fault number: 1060 (S8000, S8002, S8003, and S8006 BTS)

383

2.9.63 RIPM-USER core (source: Reset requested by active with BIST


execution)
Fault number 1060 Abis event reporting a transient default
Equipment:

RIPM-USER core

Source:

(15794193) Reset requested by active with BIST execution

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm indicates an RIPM-USER passive core restart with a BIST
execution.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
None.

TROUBLESHOOTING
No maintenance action is required.

2.9.64 RIPM-USER core (source: Reset requested by active with no


BIST execution)
Fault number 1060 Abis event reporting a transient default
Equipment:

RIPM-USER core

Source:

(15794194) Reset requested by active with no BIST execution

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm indicates an RIPM-USER passive core restart, without a BIST
execution.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
None.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

384

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

TROUBLESHOOTING
No maintenance action is required.

2.9.65 Tx Filters (source: VSWR level 2)


Fault number 1060

Abis event reporting a transient default

Equipment:

Tx Filter

Source:

(7536642) VSWR level 2

BTS model:

S8000 Outdoor + S8000 Indoor + S8003

FAULT ANALYSIS
This alarm indicates that an abnormal VSWR level has been detected at
the combiner output. The radio link is still operating.
REACTION OF THE SYSTEM

BSC defense
None.
Impact on the service
None.
TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. process the problem on the btsSiteManager
object.
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.9 Fault number: 1060 (S8000, S8002, S8003, and S8006 BTS)

If the alarm persists, go to step 2.

Otherwise, go to step 8.

385

Check that the alarm on the Tx Filter is valid, by performing


a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "VSWR" equipment is "failed", the fault is


confirmed. Go to step 3.

If the state of the "VSWR" equipment is "working", the fault is


not confirmed. Go to step 7.

On-site maintenance from the OMC-R

Check the cabling between the associated Tx Filter and the


antenna.

If it is correct, go to step 4.
If it is not correct, replace it (Shop Replaceable Unit). Go to
step 5.

In the case of alarms with source: level 2, and source: level


3, replace the associated Tx Filter (Field Replaceable Unit).
Refer to 411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting).

Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 8.


If the alarm persists, go to step 6.

Check the state of the replaced equipment by performing


a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "VSWR" equipment is still "failed", call the


manufacturer.

If the state of the "VSWR" equipment is "working", go to step


7.

Clear the alarm.

The procedure is complete.


--End--

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

386

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

2.10 Fault number: 1061 (S8000, S8002, S8003, and S8006 BTS)
Fault number:
1061

Abis mapping issue on a TDMA

Type

processingErrorAlarm

FAULT ANALYSIS
The alarm 1061 is sent when TDMA is not connected or disconnected due
to Abis resources limitations. When EDGE is activated, TDMA mask field
does not represent the TCH mapping over TDMA but the following:
When a TDMA cannot be mapped over Abis because a higher priority
TDMA has been blocked and non mapped, the TDMA mask "00000000" is
given to operator meaning "Higher priority TDMA not mapped on Abis".
When a TDMA cannot be mapped over Abis because there are not
enough resources, the TDMA mask "11111111" is given to operator
meaning "Lack of Abis resources".
Correlated notification: the attribute value change 1063 is also sent
to notify the mapping TDMA TRX and when degraded mode is used,
the cause of it. A field is added to specify if configuration is nominal or
degraded. Refer to the description of fault number 1063 in 2.11 Attribute
value change: 1063 (S8000, S8002, S8003, and S8006 BTS) (page 386)
The Managed Object (MO) is: transceiver
List of causes:

15: Lack of Abis resources


0: Higher priority TDMA not mapped on Abis

TROUBLESHOOTING
This problem is associated with a PCM fault. See 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance Procedures)

2.11 Attribute value change: 1063 (S8000, S8002, S8003, and S8006
BTS)
Fault number:
1063

TRX allocation for a TDMA

Type

processingErrorAlarm

FAULT ANALYSIS

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

387

An attribute value change 1063 (S8000, S8002, S8003, S8006) is used


to notify the mapping TDMA TRX and when degraded mode is used,
the cause of it. A field is added to specify if configuration is nominal or
degraded.
List of causes of the configuration in degraded mode:

(0): "Lack of Abis resources"

(3) "TRX insufficient EDGE capability" when TRX is not able to


respond to TDMA DS0 request

(255): "not significant", when the transceiver object is "Enabled"


without a degraded cause.

(1) "Site not supporting Edge" when Site EDGE capability <> 2
(2) "Site unsufficient number of DS0" when site is not able to respond
to the TDMA DS0 request

TROUBLESHOOTING
This problem is associated with a bad configuration of EDGE backhaul.

If the cause is (1) "Site not supporting Edge", check the PROM version
of the GTW board.

If the cause is (2) "Site unsufficient number of DS0", check the radio
site mask according to engineering rules.

If the cause is (3) "TRX insufficient EDGE capability", check if there


is an EDRX available on the cell.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)
Fault number:
1067

Abis event reporting a hardware fault

Type

equipmentAlarm

The fault number 1067 accepts causes and equipment wordings


corresponding to the eDRX, DRX, DRX-ND3, eDRX2, ePA, HePA, CMCF
phase 1 and CMCF phase 2 fault causes.
The fault numbers 1060 (transient) and 1067 (begin/end) accept these
items of equipment. The causes wording are the same for all DRX types
fault causes.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

388

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

In the case of an equipment fault or a missing item of equipment, the BTS


sends a 1067 message to the OMC-R through the BSC specifying the
faulty equipment and the source. In some cases, the BSC starts a defense
action (PCM switchover, TRX state change, reconfiguration of hopping
law, for example).
The following table indicates all the sources of the fault number 1067 for
the S8000 Outdoor and Indoor BTSs with the BCF or CBCF, for the S8002
BTSs, for the S8003 BTSs, and for the S8006 BTSs. For more information
on each source, refer to the indicated paragraph to know the corrective
maintenance procedure associated with this source.
Table 9
Fault number 1067 sources

Source No.

Source wording

S8000
Indoor
BCF

CBCF

S8
0
0
2

S8 S8
0 0
0 0
3 6

S8000
Outdoor

CBCF

BCF

Paragraph

BTS synchronization
3342340

SYNO clock not


locked on the
network

x x

2.12.16 BTS
SYNCHRONIZ
ATION (source:
SYNO clock
not locked on
the network)
(page 441)

3342341

Synchro not locked


because OCVXO
is KO

2.12.17 BTS
synchronization
(source:
Synchro not
locked because
OCVXO is
KO) (page
448)

3342342

Synchro not locked


because PCM is
not stable

3342343

GPS synchronizati
on unavailable

x x

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12.18 BTS
synchronization
(source: GPS
synchronization
unavailable)
(page 451)

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

389

Table 9
Fault number 1067 sources (contd.)

Source No.

Source wording

S8000
Indoor
BCF

S8000
Outdoor

CBCF

BCF

CBCF

S8
0
0
2

S8 S8
0 0
0 0
3 6

Paragraph

3342344

Loss of GPS
synchronization

x x

2.12.19 BTS
synchronization
(source: Loss
of GPS sync
hronization)
(page 456)

3342345

Lack of GPS
synchronization
accuracy

x x

2.12.20 BTS
SYNCHRONIZ
ATION (source:
Lack of GPS
synchronization
accuracy)
(page 461)

3342346

Master synchroniz
ation unavailable

x x

2.12.21 BTS
SYNCHRON
IZATION (so
urce: Master
synchronization
unavailable)
(page 466)

3342347

Loss of Master
GSM time

x x

2.12.22 BTS
SYNCHRONIZ
ATION (source:
Loss of master
GSM time)
(page 471)

3342348

Loss of Master SY

x x

2.12.23 BTS
SYNCHRONIZ
ATION (source:
Loss of master
SY) (page
475)

ACU cooling system


5505031

Cooler fault

ALCO board

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12.1 ACU
climatic unit
(source: Cooler
fault) (page
413)

390

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Table 9
Fault number 1067 sources (contd.)

Source No.

S8000
Indoor

Source wording

BCF
4390913

Major fault

CBCF

S8000
Outdoor
BCF

CBCF

S8
0
0
2

S8 S8
0 0
0 0
3 6

Paragraph

2.12.2 ALCO
board (source:
Major fault)
(page 416)

Battery cabinet
5832705

Over temperature

2.12.3 Battery
cabinet
(source: Over
temperature)
(page 419)

5832706

DC power fault

2.12.4 Battery
cabinet (sour
ce: DC power
fault) (page
422)

5832707

Doors

2.12.5 Battery
cabinet (sou
rce: Doors)
(page 425)

5832708

AC power fault

5832709

Surge protector

BCF cabinet door


6291457

BCF cabinet door


contact detection

2.12.6 BCF
cabinet door
contact(source:
BCF cabinet
door contact
detection)
(page 429)

2.12.7 BCF
cabinet fan
(source: BCF
cabinet fan
fault) (page
433)

BCF cabinet fan


6356993

BCF cabinet fan

BCF power supply

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

391

Table 9
Fault number 1067 sources (contd.)

Source No.

S8000
Indoor

Source wording

BCF
5373953

Volt

CBCF

S8000
Outdoor
BCF

CBCF

S8
0
0
2

S8 S8
0 0
0 0
3 6

Paragraph

2.12.8 BCF
power supply
(source: Volt)
(page 435)

Battery Remote Controller


(BRC)
6553601

Manual switch on
battery power

2.12.9 BRC
(source:
Manual switch
on battery
power) (page
438)

6553602

Automatic switch
on battery power

2.12.10 BRC
(source:
Automatic
switch on
battery power)
(page 438)

6553603

Manual switch on
main power

2.12.11 BRC
(source: Man
ual switch on
main power)
(page 438)

6553604

Automatic switch
on main power

2.12.12 BRC
(source:
Automatic
switch on main
power) (page
438)

2.12.13 BRC
(source:
Battery failure)
(page 439)

Battery Remote Controller


(BRC)
6553605

Battery Failure

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

392

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Table 9
Fault number 1067 sources (contd.)

Source No.

S8000
Indoor

Source wording

BCF

S8000
Outdoor

CBCF

BCF

CBCF

S8
0
0
2

S8 S8
0 0
0 0
3 6

Paragraph

6553606

Monitored battery
not present

2.12.14 BRC
(source:
Monitored
battery not
present) (page
440)

6553607

Internal Inconsiste
ncy

2.12.15 BRC
(source:
Internal
inconsistency)
(page 441)

Cabinet door
5898241

Door contact
detection

x x

2.12.24
Cabinet
door (source:
Door contact
detection)
(page 479)

Cavity
8388609

Cavity out of
service

2.12.25 Cavity
(source: Cavity
out of service)
(page 483)

8388610

Cavity parked after


tuning fault (min
not found)

2.12.26 Cavity
(source: Cavity
parked after
tuning fault
(min not
found)) (page
485)

8388611

Loss of cavity
initialization

2.12.27 Cavity
(source: Loss
of cavity
initialization)
(page 487)

8386612

Nack answer from


cavity

2.12.28 Cavity
(source: Nack
answer from
cavity) (page
489)

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

393

Table 9
Fault number 1067 sources (contd.)

Source No.

Source wording

S8000
Indoor
BCF

S8000
Outdoor

CBCF

BCF

CBCF

S8
0
0
2

S8 S8
0 0
0 0
3 6

Paragraph

8388613

Cavity parked after


tuning fault (power
too low)

2.12.29 Cavity
(source: Cavity
parked after
tuning fault
(power too
low)) (page
490)

8388614

Cavity parked after


tuning fault (tuning
detector problem)

2.12.30 Cavity
(source: Cavity
parked after
tuning fault
(tuning detector
problem))
(page 492)

8388615

Internal software
problem

2.12.31 Cavity
(source: Inte
rnal software
problem)
(page 494)

Cavity combiner
8323073

Power supply

2.12.32 Cavity
combiner
(source: Power
supply) (page
496)

8323074

Tuning detector
fault

2.12.33 Cavity
combiner
(source:
Tuning detector
fault) (page
498)

8323076

Link NOK

2.12.34 Cavity
combiner
(source: Link
NOK) (page
500)

C-DACS climatic system

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

394

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Table 9
Fault number 1067 sources (contd.)

Source No.

Source wording

S8000
Indoor
BCF

S8000
Outdoor

CBCF

BCF

CBCF

S8
0
0
2

S8 S8
0 0
0 0
3 6

Paragraph

7929857

Dirty filter

2.12.35
C-DACS
climatic system
(source: Dirty
filter) (page
502)

7929858

DACS failed

2.12.36
C-DACS
climatic system
(source: DACS
failed) (page
504)

CMCF
CMCF ph 1
CMCF ph 2
9502721
12779521
12845057

Major fault

x x

9502729
12779529
12845065

MCF_MCF

x x

2.12.37 CMCF
board (source:
MCF_MCF)
(page 507)

9568250
12845050
12910586

Slave downloading
error

x x

2.12.38
CMCF board
(source: Slave
downloading
error) (page
510)

12779537
12845073

duplex inhibited:
active board
is background
downloaded

x x

12779538
12845074

CMCF ACT DUPL


EX INHIBITED

x x

2.12.39 CMCF
board (source:
CMCF_ACT
_DUPLEX_I
NHIBITED)
(page 512)

CMCF ph 1
CMCF ph 2

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

395

Table 9
Fault number 1067 sources (contd.)

Source No.

S8000
Indoor

Source wording

BCF

S8000
Outdoor

CBCF

BCF

CBCF

S8
0
0
2

S8 S8
0 0
0 0
3 6

Paragraph

CMCF ACT ICST

x x

2.12.40 CMCF
board (source:
CMCF_ACT_
ICST) (page
515)

12779536

duplex inhibited:
EDGE in duplex
mix chain

x x

12779540

duplex inhibited:
feature not
supported on
CMCF phase 1

x x

2.12.41 CMCF
board (source:
Duplex inhibite
d: feature not
supported on
CMCF phase
1) (page 517)

Slave downloading
error

12779539
12845075

CMCF ph 1

CPCMI board
9633786

Combiner duplexer or H2 LNA


5570561

LNA fault

x x

2.12.42
Combiner
duplexer LNA
or combiner H2
LNA (source:
LNA fault)
(page 520)

x x

2.12.43 Comb
iner duplexer
VSWR or
combiner H2
VSWR (source:
VSWR level 1)
(page 524)

Combiner duplexer or H2 VSWR


5636097

VSWR level 1

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

396

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Table 9
Fault number 1067 sources (contd.)

Source No.

S8000
Indoor

S8000
Outdoor

BCF

CBCF

BCF

CBCF

S8
0
0
2

Source wording

S8 S8
0 0
0 0
3 6

Paragraph

5636098

VSWR level 2

x x

2.12.44 Comb
iner duplexer
VSWR or
combiner H2
VSWR (source:
VSWR level 2)
(page 524)

5636099

VSWR level 3

x x

2.12.45 Comb
iner duplexer
VSWR or
combiner H2
VSWR (source:
VSWR level 3)
(page 525)

2.12.46
Combiner H4D
LNA (source:
LNA fault)
(page 528)

Combiner H4D LNA


7405569

LNA fault

Combiner H4D VSWR


7471105

VSWR level 1

2.12.47
Combiner H4D
VSWR (source:
VSWR level 1)
(page 532)

7471106

VSWR level 2

2.12.48
Combiner H4D
VSWR (source:
VSWR level 2)
(page 534)

7471107

VSWR level 3

2.12.49
Combiner H4D
VSWR (source:
VSWR level 3)
(page 536)

Compact distribution system

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

397

Table 9
Fault number 1067 sources (contd.)

Source No.

S8000
Indoor

Source wording

BCF
7995393

S8000
Outdoor

CBCF

BCF

CBCF

S8
0
0
2

S8 S8
0 0
0 0
3 6

Main breaker

Paragraph

2.12.50
Compact distr
ibution system
(source: Main
breaker) (page
538)

CPCMI board
9568257

Major

x x

2.12.51
CPCMI board
(source:
Major) (page
541)

9633786

Slave downloading
error

x x

2.12.52
CPCMI board
(source: Slave
downloading
error) (page
541)

CSWM boards
4259849

Fault on activepassive CSWM


link or on passive
CSWM

2.12.53
CSWM board(s
ource: Fault on
active-passive
CSWM link
or on passive
CSWM) (page
544)

4325370

Slave downloading
error

2.12.54
CSWM board
(source: Slave
downloading
error) (page
547)

DACS climatic system


7864321

Dirty filter

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12.55 DACS
climatic system
(source: Dirty
filter) (page
549)

398

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Table 9
Fault number 1067 sources (contd.)

Source No.

S8000
Indoor

Source wording

BCF
7864322

S8000
Outdoor

CBCF

DACS failed

S8
0
0
2

S8 S8
0 0
0 0
3 6

Paragraph

BCF

CBCF

2.12.61 DRX
or DRX-ND3
modules
(source: HePA
not supported)
(page 570)

x x

2.12.60 DRX
or DRX-ND3
modules
(source: Abis
satellite not
supported DRX
(ND3)) (page
569)

x x

2.12.65 DRX
or eDRX or
DRX-ND3
modules
(source: RX
fault) (page
585)

2.12.56 DACS
climatic system
(source: DACS
failed) (page
551)

2.12.57 Distri
bution system
(source: Main
breaker) (page
557)

Distribution system
5767169

Main breaker

DRX
9437212

HePA not
supported

DRX, DRX ND3


9437214
12976158

Abis satellite not


supported DRX

DRX
eDRX
DRX ND3
9437185
12582913
12976129

RX fault

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

399

Table 9
Fault number 1067 sources (contd.)

Source No.

S8000
Indoor

S8000
Outdoor

BCF

CBCF

BCF

CBCF

S8
0
0
2

Source wording

S8 S8
0 0
0 0
3 6

Paragraph

9437190
12582918
12976134

BBFILTER ASIC
fault

x x

2.12.63 DRX
or eDRX or
DRX-ND3 mod
ules (source:
BBFILTER
ASIC fault)
(page 576)

9437193
12582921
12976137

Self test failed

x x

2.12.78 DRX
or eDRX or
DRX-ND3
or eDRX2
modules
(source: Self
test failed)
(page 609)

9437194
12582922
12976138

Major fault on TX

x x

2.12.72 DRX
or eDRX or
DRX-ND3
or eDRX2
modules
(source: Major
fault on TX)
(page 597)

9437206
12582934
12976150

DRX link

x x

2.12.69 DRX
or eDRX or
DRX-ND3
or eDRX2
modules
(source: DRX
link) (page
591)

9437211
12582939
12976155

(H) (e) PA
configuration not
supported

x x

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

400

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Table 9
Fault number 1067 sources (contd.)

Source No.

S8000
Indoor

S8000
Outdoor

BCF

CBCF

BCF

CBCF

S8
0
0
2

Source wording

S8 S8
0 0
0 0
3 6

Paragraph

9437216
12582944
12976160

The TX has not


acknowledged the
power consign
request

x x

2.12.64 DRX
or eDRX or
DRX-ND3
modules
(source: The
TX has not
acknowledged
the power
consign
request) (page
580)

9437217
12582945
12976161

PA DRX control
loop fault

x x

2.12.74 DRX
or eDRX or
DRX-ND3
or eDRX2
modules
(source: PA
DRX control
loop fault)
(page 602)

9437218
12582946
12976162

DRX reset by BCF


after message non
acknowledgement

x x

2.12.73 DRX
or eDRX or
DRX-ND3
or eDRX2
modules
(source: Nack
answer) (page
602)

9437219
12582947
12976163

DRX link NOK


after reset
requested by BSC

x x

2.12.70 DRX
or eDRX or
DRX-ND3
or eDRX2
modules
(source: DRX
reset by BSC)
(page 596)

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

401

Table 9
Fault number 1067 sources (contd.)

Source No.

S8000
Indoor

S8000
Outdoor

BCF

CBCF

BCF

CBCF

S8
0
0
2

Source wording

S8 S8
0 0
0 0
3 6

Paragraph

9502719
12648447
13041663

TRX not anymore


configured

x x

2.12.79 DRX
or eDRX or
DRX-ND3
or eDRX2
modules
(source: TRX
not anymore
configured)
(page 613)

9437211
or
12582939

PA configuration
exceeded

2.12.62 DRX
or DRX-ND3
modules
(source: PA
configuration
exceeded)
(page 573)

Post-mortem dump
zone 3

x x

2.12.75 DRX
or eDRX or
DRX-ND3 or
eDRX2 mod
ules (source:
Post-mortem
dump zone 3)
(page 607)

S8
0
0
2

S8 S8
0 0
0 0
3 6

9437427 or
12583155 or
12976371

Table 10
Fault number 1067 sources (continued)

Source No.

Source
wording

S8000
Indoor
BCF

CBCF

S8000
Outdoor
BCF

CBCF

DRX
eDRX
DRX ND3

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

Paragraph

402

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Table 10
Fault number 1067 sources (continued) (contd.)

Source No.

Source
wording

S8000
Indoor

S8000
Outdoor

BCF

CBCF

BCF

CBCF

S8
0
0
2

S8 S8
0 0
0 0
3 6

Paragraph

9437456
or
12583184
or
12976400

BCCH first config


failed

x x

2.12.67 DRX
or eDRX or
DRX-ND3
or eDRX2
modules
(source: BCCH
first config
failed) (page
589)

9437457
or
12583185
or
12976401

BCCH second
config failed

x x

2.12.68 DRX
or eDRX or
DRX-ND3
or eDRX2
modules
(source: BCCH
second config
failed) (page
590)

9437472
or
12583200
or
12976416

SACCH first config


failed

x x

2.12.76 DRX
or eDRX or
DRX-ND3 or
eDRX2 mod
ules (source:
SACCH first
config failed)
(page 607)

9437473
or
12583201
or
12976417

SACCH second
config failed

x x

2.12.77 DRX
or eDRX or
DRX-ND3
or eDRX2
modules (sou
rce: SACCH
second config
failed) (page
608)

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

403

Table 10
Fault number 1067 sources (continued) (contd.)

Source No.

Source
wording

S8000
Indoor

S8000
Outdoor

BCF

CBCF

BCF

CBCF

S8
0
0
2

S8 S8
0 0
0 0
3 6

Paragraph

9437488
or
12583216
or
12976432

L1M first config


failed

x x

2.12.66 DRX
or eDRX or
DRX-ND3
modules
(source: L1M
first config
failed) (page
589)

9437489
or
12583217
or
12976433

L1M second config


failed

x x

2.12.71 DRX
or eDRX or
DRX-ND3
or eDRX2
modules
(source: L1M
second config
failed) (page
597)

x x

2.12.58 DRX
or DRX-ND3
diversity
reception
chain (source:
Software
detection)
(page 560)

x x

2.12.59 DRX
or DRX-ND3
main reception
chain (source:
Software
detection)
(page 565)

DRX diversity reception chain


6946817

Software detection

DRX main reception chain


6881281

Software detection

DSC boards
4456449

Major fault

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12.80 DSC
boards (source:
Major fault)
(page 616)

404

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Table 10
Fault number 1067 sources (continued) (contd.)

Source No.

4456453

Source
wording
Channel_HSCX

S8000
Indoor
BCF

S8000
Outdoor

CBCF

BCF

CBCF

S8
0
0
2

S8 S8
0 0
0 0
3 6

Paragraph

2.12.81 DSC
boards (source:
Channel_HSC
X) (page 618)

eDRX2
15204361

Self test failed

2.12.78 DRX
or eDRX or
DRX-ND3
or eDRX2
modules
(source: Self
test failed)
(page 609)

15204362

Major fault on TX

2.12.72 DRX
or eDRX or
DRX-ND3
or eDRX2
modules
(source: Major
fault on TX)
(page 597)

15204374

DRX link

2.12.69 DRX
or eDRX or
DRX-ND3
or eDRX2
modules
(source: DRX
link) (page
591)

15204374

DRX link

2.12.69 DRX
or eDRX or
DRX-ND3
or eDRX2
modules
(source: DRX
link) (page
591)

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

405

Table 10
Fault number 1067 sources (continued) (contd.)

Source No.

Source
wording

S8000
Indoor
BCF

S8000
Outdoor

CBCF

BCF

CBCF

S8
0
0
2

S8 S8
0 0
0 0
3 6

Paragraph

15204385

PA DRX control
loop fault

2.12.73 DRX
or eDRX or
DRX-ND3
or eDRX2
modules
(source: Nack
answer) (page
602)

15204386

DRX reset by BCF


after message non
acknowledgement

2.12.73 DRX
or eDRX or
DRX-ND3
or eDRX2
modules
(source: Nack
answer) (page
602)

15204387

DRX link NOK


after reset
requested by BSC

2.12.70 DRX
or eDRX or
DRX-ND3
or eDRX2
modules
(source: DRX
reset by BSC)
(page 596)

15269887

TRX not anymore


configured

x x

2.12.79 DRX
or eDRX or
DRX-ND3
or eDRX2
modules
(source: TRX
not anymore
configured)
(page 613)

15204624

BCCH first config


failed

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12.67 DRX
or eDRX or
DRX-ND3
or eDRX2
modules
(source: BCCH
first config
failed) (page
589)

406

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Table 10
Fault number 1067 sources (continued) (contd.)

Source No.

Source
wording

S8000
Indoor
BCF

S8000
Outdoor

CBCF

BCF

CBCF

S8
0
0
2

S8 S8
0 0
0 0
3 6

Paragraph

15204625

BCCHsecond
config failed

2.12.68 DRX
or eDRX or
DRX-ND3
or eDRX2
modules
(source: BCCH
second config
failed) (page
590)

15204640

SACCH first config


failed

2.12.76 DRX
or eDRX or
DRX-ND3 or
eDRX2 mod
ules (source:
SACCH first
config failed)
(page 607)

15204641

SACCH second
config failed

2.12.77 DRX
or eDRX or
DRX-ND3
or eDRX2
modules (sou
rce: SACCH
second config
failed) (page
608)

15204656

L1M first config


failed

2.12.66 DRX
or eDRX or
DRX-ND3
modules
(source: L1M
first config
failed) (page
589)

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

407

Table 10
Fault number 1067 sources (continued) (contd.)
Source
wording

Source No.

S8000
Indoor
BCF

S8000
Outdoor

CBCF

BCF

CBCF

S8
0
0
2

S8 S8
0 0
0 0
3 6

Paragraph

15204657

L1M second config


failed

2.12.71 DRX
or eDRX or
DRX-ND3
or eDRX2
modules
(source: L1M
second config
failed) (page
597)

15204595

Post-mortem dump
zone 3

2.12.75 DRX
or eDRX or
DRX-ND3 or
eDRX2 mod
ules (source:
Post-mortem
dump zone 3)
(page 607)

x x

2.12.95 Not
protected
alarm (source:
Alarm) (page
646)

x x

2.12.82
External
alarm (source:
Alarm) (page
621)

Not protected alarm


3735553

Alarm

External alarm
x

7274497

Fan of the base cabinet


6225921

Cabinet fan fault

F-type converters

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12.83 Fan
of the base ca
binet (source:
Cabinet fan
fault) (page
621)

408

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Table 10
Fault number 1067 sources (continued) (contd.)
S8000
Outdoor

BCF

CBCF

BCF

CBCF

Volt

Major fault on
GTW

Source No.

5308417

S8000
Indoor

S8
0
0
2

Source
wording

S8 S8
0 0
0 0
3 6
x x

Paragraph

2.12.84 F-type
converters
(source: Volt)
(page 624)

GTW boards
4587521

2.12.85 GTW
boards (source:
Major fault on
GTW) (page
628)

Internal batteries
5439489

Battery disconnect
ed

2.12.94 Lightn
ing protector
(source:
Lightning
protection
fault) (page
643)

2.12.86 Intern
al batteries (s
ource: Battery
disconnected)
(page 631)

Lightning protector
6160385

Lightning
protection fault

Output Rx-splitter D
9764865

Over current

x x

2.12.96 Output
Rx-splitter D
(source: Over
current) (page
646)

Over current

x x

2.12.97 Output
Rx-splitter M
(source: Over
current) (page
649)

Output
Rx-splitter
M
9699329

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

409

Table 10
Fault number 1067 sources (continued) (contd.)
S8000
Indoor

S8000
Outdoor

S8 S8
0 0
0 0
3 6
x x

BCF

CBCF

BCF

CBCF

S8
0
0
2

PCM

Major fault on
PCMI

6815745
or
12648449
or
12713985

Hardware

x x

2.12.100
Power ampli
fiers (source:
Hardware)
(page 652)

6815746
or
12648450
or
12713986

DRX and PA
connection

x x

2.12.101
Power ampli
fiers (source:
DRX and PA
connection)
(page 658)

6815747
or
12648451
or
12713987

High temp

x x

2.12.102 Po
wer amplifiers
(source: High
temperature )
(page 663)

6815748
or
12648452
or
12713988

High Current

x x

2.12.103 Po
wer amplifiers
(source: High
Current )
(page 667)

6815750
or
12648454
or
12713990

PA_PSDW

x x

2.12.104
Power ampli
fiers (source:
PA_PSDW )
(page 671)

Source
wording

Source No.

Paragraph

PCM
6488065

2.12.98 PCM
(source: PCM)
(page 652)

PCMI boards
4521985

2.12.99 PCMI
boards (source:
Major fault on
PCMI) (page
652)

PA or ePA
or HePA

PA

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

410

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Table 10
Fault number 1067 sources (continued) (contd.)

Source No.

6815751

Source
wording
VSWR fault
detected by PA

S8000
Indoor

S8000
Outdoor

S8 S8
0 0
0 0
3 6

BCF

CBCF

BCF

CBCF

S8
0
0
2

x x

2.12.105
Power ampli
fiers (source:
VSWR fault
detected by
PA) (page
675)

Paragraph

RECAL board
9633793

Major

x x

2.12.106
RECAL
board (source:
Major) (page
676)

9699322

Slave downloading
error

x x

2.12.107
RECAL board
(source: Slave
downloading
error) (page
679)

Rectifiers
5242881

AC fault

2.12.108
Rectifiers
(source: AC
fault) (page
682)

5242882

DC fault

2.12.109
Rectifiers
(source: DC
fault) (page
686)

5242883

Over temperature

2.12.110
Rectifiers
(source: Over
temperature)
(page 688)

5242884

External battery
level 1

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12.111
Rectifiers (s
ource: External
battery level 1)
(page 691)

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

411

Table 10
Fault number 1067 sources (continued) (contd.)

Source No.

Source
wording

S8000
Indoor

S8000
Outdoor

BCF

CBCF

BCF

CBCF

S8
0
0
2

S8 S8
0 0
0 0
3 6
x

Paragraph

5242885

PCU protective

5242886

Battery on
discharges

Major fault on
SYNC

LNA Fault

7536642

VSWR level 2

2.12.120 Tx
Filters (source:
VSWR level 2)
(page 709)

7536643

VSWR level 3

2.12.121 Tx
Filters (source:
VSWR level 3)
(page 710)

User alarm

2.12.112
Rectifiers
(source: PCU
protective)
(page 693)
2.12.113
Rectifiers
(source:
Battery on
discharges)
(page 697)

SYNC boards
4325377

2.12.119
SYNC boards
(source:
Major fault on
SYNC) (page
707)

Rx Filter
7602177

2.12.118 Rx
Filter (source:
LNA fault)
(page 704)

Tx Filters

User system
5701633

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

412

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Table 11
Fault number 1067 sources (IP)

Source No.

Cause
wording

S8000
Indoor
BC CB
F CF

S8000
Outd
oor

S8
0
0
BC CB 2
F CF

S8
0
0
3

S8
0
0
6

Paragraph

IPM-USER core
15728672

IPM BIST failed

2.12.91 IPM-USER core


(source: IPM BIST failed)
(page 639)

15728675

IPM temperature

2.12.92 IPM-USER core


(source: IPM temperature)
(page 640)

15728688

DAC unable to loc


k, synchronisation
not possible

2.12.93 IPM-USER core


(source: DAC unable to
lock, synchronization not
possible) (page 641)

RIPM-USER core
15794208

IPM BIST failed

2.12.114 RIPM-USER core


(source: IPM BIST failed)
(page 699)

15794211

IPM temperature

2.12.115 RIPM-USER core


(source: IPM temperature)
(page 700)

15794224

DAC unable to loc


k, synchronisation
not possible

2.12.116 RIPM-USER core


(source: DAC unable to
lock, synchronization not
possible) (page 701)

15794241

No link with
passive

2.12.117 RIPM-USER core


(source: No link with passive)
(page 703)

IP synchro
15859968

Unable to lock on
IP synchronization

2.12.87 IP synchro (source:


Unable to lock on IP
synchronization) (page 634)

15859969

Not enough
synchronization
packets have been
received.

2.12.88 IP synchro (source:


Not enough synchronization
packets have been received)
(page 636)

Ethernet switch

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

Cause
wording

Source No.

15925760

S8000
Indoor
BC CB
F CF
x

Ethernet switch is
disconnected on
user port

S8000
Outd
oor

S8
0
0
BC CB 2
F CF

S8
0
0
3

S8
0
0
6

413

Paragraph

Ethernet switch (source:


Ethernet switch is
disconnected on used port)

IPM-USER commissioning
15663140

Only one IBOS


commissioned at
IPM

2.12.89 IPM-USER
commissioning (source:
Only one IBOS commissioned
at IPM) (page 637)

15663141

DNS resolution
has failed for at
least one IBOS

2.12.90 IPM-USER
commissioning (source: DNS
resolution has failed for at
least one IBOS) (page 638)

2.12.1 ACU climatic unit (source: Cooler fault)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

Cooler system

Source:

(5505031) Cooler fault

BTS model:

S8000 Outdoor

FAULT ANALYSIS
This alarm is detected by the ALCO or RECAL board.
It is an "OR" function of all the alarms that are liable to occur on the
climatic unit.

REACTION OF THE SYSTEM

As long as the temperature of the (H)(e)PAs is lower than 60C


(140F), there is no BSC defense action.

As soon as the temperature of the (H)(e)PAs is higher than 60C,


there is a voluntary cut of the (H)(e)PAs. Then the BSC unconfigures
the transceiverEquipment and transceiver objects, and possibly the
btsSiteManager and bts objects.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

414

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

CAUTION
Service interruption
The service is progressively lost.

CAUTION
Working instructions
Intervention on the site must be immediate.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).
If not, look for an object whose state is "disabled-failed"
and process the problem so that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem so that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait until the state of the btsSiteManager
object becomes "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

If the alarm persists, go to step 2.

Otherwise, go to step 9.

415

Check that the alarm on the ACU climatic units is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of a "cooler system" equipment is "failed", the fault


is confirmed. Go to step 3.

If the state of the "cooler system" equipment is "working", the


fault is not confirmed. Go to step 8.

On-site maintenance

Check that the main breaker, the climatic system circuit breaker
and the circuit breaker L2/CB2 are in the "I" position. If they are
not, put them in the "I" position.

Remove the filter of the faulty ACU (see 411-9001-048 (Nortel


GSM BTS S8000/S8003 Troubleshooting)).

Reset the two internal AC and DC circuit breakers of the ACU


(located behind the filter) once.

If the circuit breakers can not be reset, replace the climatic


unit (Field Replaceable Unit). It can be replaced either by
another ACU or by a DACS.
To replace the climatic unit with another ACU, refer
to 411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting).
To replace the climatic unit with a DACS, refer to
411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting) to remove the ACU, and to install the
DACS.
Go to step 6.

If the circuit breakers can be reset, measure the ambient


temperature of the cabinet.
If the temperature is between -40C (-40F) and +50C
(+122F), there is an internal problem in the climatic unit.
Replace the climatic unit (Field Replaceable Unit). It can
be replaced either by another ACU or by a DACS.

To replace the climatic unit with another ACU, refer


to 411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting).

To replace the climatic unit with a DACS, refer to


411-9001-048 (Nortel GSM BTS S8000/S8003

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

416

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Troubleshooting) to remove the ACU and to install the


DACS.
Go to step 6.
If the temperature is lower than -40C or higher than
+50C, wait for the system to return to a normal
temperature. The cabinet will restart automatically,
triggered by the thermostats.

The high temperature thermostat triggers the cabinet


start-up if the temperature is lower than 61C
(+141.8F).

The low temperature thermostat triggers the cabinet


start-up if the temperature is upper than 9C
(+48.2F).

Go to step 6.
Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 9.


If the alarm persists, go to step 7.

Check the state of the ACU climatic unit by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "cooler system" equipment is still "failed",


call the manufacturer.

If the state of the "cooler system" equipment is "working", go


to step 8.

Clear the alarm.

The procedure is complete.


--End--

2.12.2 ALCO board (source: Major fault)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

ALCO

Source:

(4390913) Major fault

BTS model:

S8000 Outdoor + S8000 Indoor

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

417

FAULT ANALYSIS
This alarm indicates an ALCO board failure that may be due to the fuse on
the front panel of the BCF, the power supply voltage on the PWR cable or
the cabling between the BCF and the board.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service The BTS no longer supervises all the items of
equipment linked to the ALCO board (distribution system, rectifiers, F-type
converters, BCF power supplies, internal batteries, climatic system, LNA,
VSWR, door contact, lightning protection and battery cabinet).
The S8000 BTS service is no longer supervised, as the BTS cannot inform
the BSC.

CAUTION
Service interruption
The service can be lost, even though the OMC-R does not
indicate any loss.

CAUTION
Working instructions
Intervention on the site must be immediate.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

418

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

GSM BSS Fault Clearing - Advanced Maintenance


Procedures)).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 8.

Check that the alarm on the ALCO board is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "ALCO" equipment is "failed", the fault is


confirmed. Go to step 3.

If the state of the "ALCO" equipment is "working", the fault is


not confirmed. Go to step 7.

On-site maintenance

Check the ALCO board fuse on the BCF front panel for the
S8000 Outdoor or the ALCO/BCF circuit breaker for the S8000
Indoor.

If it is correct, go to step 4.
If it is not correct, replace it (Shop Replaceable Unit).
If the alarm persists, go to step 4.
If the alarm has disappeared, go to step 8.

Check the power supply voltage on the PWR cable by measuring


with a voltmeter.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

419

If the voltage is lower than -58V and higher than -40V,


replace the ALCO board (Field Replaceable Unit).
Refer to 411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting). Go to step 5.

If the voltage is between -58V and -40V, replace the O and


M cable (Shop Replaceable Unit) between the BCF and the
ALCO board. Go to step 5.

Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 8.


If the alarm persists, go to step 6.

Check the state of the ALCO board by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "ALCO" equipment is still "failed", call the


manufacturer.

If the state of the "ALCO" equipment is "working", go to step


7.

Clear the alarm.

The procedure is complete.


--End--

2.12.3 Battery cabinet (source: Over temperature)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

Battery cabinet

Source:

(5832705) Over temperature

BTS model:

S8000 Outdoor

FAULT ANALYSIS
This alarm is detected by the ALCO or RECAL board.
It is triggered by a problem with the climatic unit of the battery cabinet:
the temperature of the battery cabinet has become either too high (over
+ 65C), or too low (below + 5C).

REACTION OF THE SYSTEM


BSC defense
None.
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

420

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Impact on the service

None.

CAUTION
Working instructions
Intervene within 24 hours.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed" and process the
problem in order that the btsSiteManager object becomes
"enabled".
If no object is concerned and if a fault number 1054 (loss
of layer 2) has appeared:

If the cabinet is out of order, process the problem on


the cabinet. Go to step 3.

Otherwise, refer to the fault number 1054 (see


411-9001-105 (Nortel GSM BSS Fault Clearing Advanced Maintenance Procedures)).

If a pcmCircuit object is "disabled-failed":

If the cabinet is out of order, process the problem on


the cabinet. Go to step 3.

Look for a fault number concerning PCMs (see


411-9001-105 (Nortel GSM BSS Fault Clearing Advanced Maintenance Procedures)).

If an lapdLink object is "disabled-failed", the BSC is


concerned. Look for alarms concerning the BSC.

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

421

a. As long as the operationalState of the btsSiteManager


object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 8.

Check that the alarm on the battery cabinet is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "battery cabinet" equipment is "failed", the


fault is confirmed. Go to step 4.

If the state of the "battery cabinet" equipment is "working", the


fault is not confirmed. Go to step 7.

On-site maintenance

Check the state of the mains power supply on the operator box.

If the mains power supply is correct, it is a PCM fault. Refer


to the fault number 1054 (see 411-9001-105 (Nortel GSM
BSS Fault Clearing - Advanced Maintenance Procedures)
Paragraph 12.4.2.6).

If not, solve the problem concerning the mains power supply


and go to step 5.

Replace the heating and ventilation unit of the battery cabinet


(Field Replaceable Unit). Refer to 411-9001-048 (Nortel GSM
BTS S8000/S8003 Troubleshooting). Go to step 5.

Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 8.


If the alarm persists, go to step 6.

Check the state of the battery cabinet by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "battery cabinet" equipment is still "failed",


call the manufacturer.

If the state of the "battery cabinet" equipment is "working",


go to step 7.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

422

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Clear the alarm.

The procedure is complete.


--End--

2.12.4 Battery cabinet (source: DC power fault)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

Battery cabinet

Source:

(5832706) DC power fault

BTS model:

S8000 Outdoor

FAULT ANALYSIS
This alarm is detected by the ALCO or RECAL board, and occurs when
there is a power supply problem of the battery cabinet.
If the BTS operates on its external batteries, there are no internal batteries.

REACTION OF THE SYSTEM


BSC defense If the S8000 BTS operates on batteries, there is no BSC
defense action until the batteries reach the threshold level. In this case,
the BSC unconfigures the btsSiteManager object. The btsSiteManager,
bts and transceiverEquipment objects change their state: they become
"disabled-dependency". The pcmCircuit of the Abis link becomes
"disabled-failed".

CAUTION
Working instructions
Intervention on the site must be immediate. There is a risk of
site loss.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed" and process the

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

423

problem in order that the btsSiteManager object becomes


"enabled".
If no object is concerned and if a fault number 1054 (loss
of layer 2) has appeared:

If the cabinet is out of order, process the problem on


the cabinet. Go to step 5.

Otherwise, refer to the fault number 1054 (see


411-9001-105 (Nortel GSM BSS Fault Clearing Advanced Maintenance Procedures)).

If a pcmCircuit object is "disabled-failed":

If the cabinet is out of order, process the problem on


the cabinet. Go to step 5.

Look for a fault number concerning PCMs (see


411-9001-105 (Nortel GSM BSS Fault Clearing Advanced Maintenance Procedures)).

If an lapdLink object is "disabled-failed", the BSC is


concerned. Look for alarms concerning the BSC.

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 13.

Check that the alarm on the battery cabinet is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "battery cabinet" equipment is "failed", the


fault is confirmed. Go to step 3.

If the state of the "battery cabinet" equipment is "working", the


fault is not confirmed. Go to step 12.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

424

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers


On-site maintenance

If the alarm appears and there are no external batteries, go to


step 4. Otherwise, go to step 6.

Check the "external battery cabinet" parameter by performing the


"Display" command on the btsSiteManager object.

If the parameter is "present", set its value to "absent".


If the alarm has disappeared, go to step 13.
If the alarm persists, go to step 5.

If the parameter is "absent", go to step 10.

Check the state of the mains power supply on the operator box.

If the mains power supply is correct, it is a PCM fault. Refer


to the fault number 1054 (see 411-9001-105 (Nortel GSM
BSS Fault Clearing - Advanced Maintenance Procedures)).

If not, solve the problem concerning the mains power supply


and go to step 6.

Check the state of the circuit breakers of the battery cabinet.

If the circuit breakers of the battery cabinet are not in the "I"
position, put the DC circuit breaker in the "I" position.
In the case of a new break, go to step 7.
Otherwise, go to step 9.

If the circuit breakers of the battery cabinets are in the "I"


position, go to step 7.

Check the external batteries (see 411-9001-048 (Nortel GSM


BTS S8000/S8003 Troubleshooting)).

If the test is failed, replace the external batteries (Field


Replaceable Unit). Refer to 411-9001-048 (Nortel GSM BTS
S8000/S8003 Troubleshooting).
If the alarm has disappeared, go to step 13.
If the alarm persists, go to step 8.

If the test is correct, disconnect the cables of the battery


cabinet. Go to step 9.

Put the DC circuit breaker of the battery cabinet in the "I"


position.

In the case of a new break, replace the DC circuit


breaker of the battery cabinet (Field Replaceable Unit).
Refer to 411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting).

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

425

If the alarm has disappeared, go to step 13.


If the alarm persists, go to step 9.

Otherwise, check the cables between the batteries and the


circuit breaker.
If the cables are correct, go to step 9.
If the cables are not correct, replace them (Shop
Replaceable Unit).

If the alarm has disappeared, go to step 13.

If the alarm persists, go to step 9.

Replace the ALCO or RECAL board (Field Replaceable Units).

For the ALCO board, refer to 411-9001-048 (Nortel GSM BTS


S8000/S8003 Troubleshooting).

For the RECAL board, refer to 411-9001-048 (Nortel GSM


BTS S8000/S8003 Troubleshooting).

Go to step 10.
Additional checks

10

Check the alarm state in the "Current Alarm list" window.

11

If the alarm has disappeared, go to step 13.


If the alarm persists, go to step 11.

Check the state of the battery cabinet by performing the "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "battery cabinet" equipment is still "failed",


call the manufacturer.

If the state of the "battery cabinet" equipment is "working",


go to step 12.

12

Clear the alarm.

13

The procedure is complete.


--End--

2.12.5 Battery cabinet (source: Doors)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

Battery cabinet

Source:

(5832707) Doors

BTS model:

S8000 Outdoor

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

426

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

FAULT ANALYSIS
This alarm is detected by the ALCO or RECAL board.
This alarm indicates that a door is open.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service

There is no immediate impact.

CAUTION
Working instructions
If an intervention is being performed on the battery cabinet, the
door is open. Therefore, the alarm is normal.
However, if no intervention is being performed on the battery
cabinet, this alarm is not normal. Intervention on the site must
be immediate. If the doors remain open, temperature problems
could arise.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed" and process the
problem in order that the btsSiteManager object becomes
"enabled".
If no object is concerned and if a fault number 1054 (loss
of layer 2) has appeared:

If the cabinet is out of order, process the problem on


the cabinet. Go to step 3.

Otherwise, refer to the fault number 1054 (see


411-9001-105 (Nortel GSM BSS Fault Clearing Advanced Maintenance Procedures)).

If a pcmCircuit object is "disabled-failed":

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

427

If the cabinet is out of order, process the problem on


the cabinet. Go to step 3.

Look for a fault number concerning PCMs (see


411-9001-105 (Nortel GSM BSS Fault Clearing Advanced Maintenance Procedures)).

If an lapdLink object is "disabled-failed", the BSC is


concerned. Look for alarms concerning the BSC.

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 15.

Check that the alarm on the door contact is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "battery cabinet" equipment is "failed", the


fault is confirmed. Go to step 4.

If the state of the "battery cabinet" equipment is "working", the


fault is not confirmed. Go to step 14.

On-site maintenance

Check the state of the mains power supply on the operator box.

If the mains power supply is correct, it is a PCM fault. Refer


to the fault number 1054 (see 411-9001-105 (Nortel GSM
BSS Fault Clearing - Advanced Maintenance Procedures)).

If not, solve the problem concerning the mains power supply


and go to step 12.

If the alarm appears and the door is closed, go to step 5.


Otherwise, go to step 14.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

428

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Check the door contact.

If it is not correct, replace it (Shop Replaceable Unit). Go to


step 6.

Check the alarm state in the "Current Alarm list" window.

If it is correct, go to step 7.

If the alarm has disappeared, go to step 15.


If the alarm persists, go to step 7.

Check the state of the battery cabinet by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "battery cabinet" equipment is still "failed",


go to step 8.

If the state of the "battery cabinet" equipment is "working",


go to step 14.

Check the cable between the door contact and the ALCO or
RECAL board.

If it is not correct, replace it (Shop Replaceable Unit). Go to


step 9.

Check the alarm state in the "Current Alarm list" window.

10

If it is correct, go to step 11.

If the alarm has disappeared, go to step 15.


If the alarm persists, go to step 10.

Check the state of the battery cabinet by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

11

If the state of the "battery cabinet" equipment is still "failed",


go to step 11.

If the state of the "battery cabinet" equipment is "working",


go to step 14.

Replace the ALCO or RECAL board (Field Replaceable Units).

For the ALCO board, refer to 411-9001-048 (Nortel GSM BTS


S8000/S8003 Troubleshooting).

For the RECAL board, refer to 411-9001-048 (Nortel GSM


BTS S8000/S8003 Troubleshooting).

Go to step 12.
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

429

Additional checks

12

Check the alarm state in the "Current Alarm list" window.

13

If the alarm has disappeared, go to step 15.


If the alarm persists, go to step 13.

Check the state of the battery cabinet by performing the "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "battery cabinet" equipment is still "failed",


call the manufacturer.

If the state of the "battery cabinet" equipment is "working",


go to step 14.

14

Clear the alarm.

15

The procedure is complete.


--End--

2.12.6 BCF cabinet door contact


(source: BCF cabinet door contact detection)
Fault number 1067

Abis event reporting a hardware fault

Equipment:

BCF Cabinet door

Source:

(6291457) BCF cabinet door contact detection

BTS model:

S8000 Indoor

FAULT ANALYSIS
This alarm is detected by the ALCO or RECAL board.
This alarm indicates that the BCF cabinet door has been opened
(begin-of-fault) or closed (end-of-fault).

REACTION OF THE SYSTEM


BSC defense
None.
BSC defense
None.
Impact on the service

There is no immediate impact on the service.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

430

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

CAUTION
Working instructions
If an intervention is being performed on the BCF cabinet, the
door is open. Therefore, the alarm is normal.
However, if no intervention is being performed on the BCF
cabinet, this alarm is not normal. Intervention on the site must
be immediate. If the door remains open, temperature problems
could arise.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed" and process the
problem in order that the btsSiteManager object becomes
"enabled".
If no object is concerned and if a fault number 1054 (loss
of layer 2) has appeared:

If the cabinet is out of order, process the problem on


the cabinet. Go to step 3.

Otherwise, refer to the fault number 1054 (see


411-9001-105 (Nortel GSM BSS Fault Clearing Advanced Maintenance Procedures)).

If a pcmCircuit object is "disabled-failed":

If the cabinet is out of order, process the problem on


the cabinet. Go to step 3.

Look for a fault number concerning PCMs (see


411-9001-105 (Nortel GSM BSS Fault Clearing Advanced Maintenance Procedures)).

If an lapdLink object is "disabled-failed", the BSC is


concerned. Look for alarms concerning the BSC.

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

431

process the problem in order that the btsSiteManager object


becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 15.

Check that the alarm on the door contact is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "BCF cabinet door" equipment is "failed",


the fault is confirmed. Go to step 4.

If the state of the "BCF cabinet door" equipment is "working",


the fault is not confirmed. Go to step 14.

On-site maintenance

Check the state of the mains power supply on the operator box.

If the mains power supply is correct, it is a PCM fault. Refer


to the fault number 1054 (see 411-9001-105 (Nortel GSM
BSS Fault Clearing - Advanced Maintenance Procedures)).

If not, solve the problem concerning the mains power supply


and go to step 12.

If the alarm appears but the door is closed, go to step 5.


Otherwise, go to step 14.

Replace the ALCO board (Field Replaceable Unit). Refer to


411-9001-048 (Nortel GSM BTS S8000/S8003 Troubleshooting).
Then go to step 6.

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 15.


If the alarm persists, go to step 7.

Check the state of the door contact by performing a "Display


hardware configuration" command on the btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

432

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Look at the result displayed in the "Session log" window.

If the state of the "BCF door contact" equipment is still


"failed", go to step 8.

If the state of the "BCF door contact" equipment is "working",


go to step 14.

Check the cable between the BCF and the connection panel.

If it is not correct, replace it (Shop Replaceable Unit). Go to


step 9.

Check the alarm state in the "Current Alarm list" window.

10

If it is correct, go to step 11.

If the alarm has disappeared, go to step 15.


If the alarm persists, go to step 10.

Check the state of the door contact by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

11

If the state of the "BCF door contact" equipment is still


"failed", go to step 11.

If the state of the "BCF door contact" equipment is "working",


go to step 14.

Check the cable between the connection panel and the ALCO
board.

If it is correct, go to step 12.


If it is not correct, replace it (Shop Replaceable Unit). Go to
step 12.

Additional checks

12

Check the alarm state in the "Current Alarm list" window.

13

If the alarm has disappeared, go to step 15.


If the alarm persists, go to step 13.

Check the state of the door contact by performing the "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "BCF door contact" equipment is still


"failed", call the manufacturer.

If the state of the "BCF door contact" equipment is "working",


go to step 14.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

14

Clear the alarm.

15

The procedure is complete.

433

--End--

2.12.7 BCF cabinet fan (source: BCF cabinet fan fault)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

BCF Cabinet fan

Source:

(6356993) BCF cabinet fan fault

BTS model:

S8000 Indoor

FAULT ANALYSIS
This alarm indicates that a BCF cabinet fan is faulty.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service

None.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

434

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

process the problem in order that the btsSiteManager object


becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 9.

Check that the alarm on the BCF cabinet fan is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "BCF Cabinet fan" equipment is "failed", the


fault is confirmed. Go to step 3.

If the state of the "BCF Cabinet fan" equipment is "working",


the fault is not confirmed. Go to step 8.

On-site maintenance

Check the mains power supply on the operator box.

If the mains power supply is correct, it is a PCM fault. Refer


to the fault number 1054 (see 411-9001-105 (Nortel GSM
BSS Fault Clearing - Advanced Maintenance Procedures)).

If not, solve the problem concerning the mains power supply


and go to step 4.

Check the state of the fuse.

If it is correct, go to step 5.
If it is not correct, replace it (Shop Replaceable Unit). Go to
step 6.

Replace the faulty fan (Field Replaceable Unit). Refer to


411-9001-048 (Nortel GSM BTS S8000/S8003 Troubleshooting).
Go to step 6.

Additional checks

Check the alarm state in the "Current Alarm list" window.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

435

If the alarm has disappeared, go to step 9.


If the alarm persists, go to step 7.

Check the state of the BCF cabinet fan by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "BCF cabinet fan" equipment is still "failed",


call the manufacturer.

If the state of the "BCF cabinet fan" equipment is "working",


go to step 8.

Clear the alarm.

The procedure is complete.


--End--

2.12.8 BCF power supply (source: Volt)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

Converter BCF

Source:

(5373953) Volt

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm is detected by the ALCO board.
This alarm indicates that a BCF power supply is faulty.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service

None.

TROUBLESHOOTING
Step

Action

Preliminary checks

Perform a "Display all" command on the btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

436

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed" and process the
problem in order that the btsSiteManager object becomes
"enabled".
If no object is concerned and if a fault number 1054 (loss
of layer 2) has appeared:

If the cabinet is out of order, process the problem on


the cabinet. Go to step 4.

Otherwise, refer to the fault number 1054 (see


411-9001-105 (Nortel GSM BSS Fault Clearing Advanced Maintenance Procedures)).

If a pcmCircuit object is "disabled-failed":

If the cabinet is out of order, process the problem on


the cabinet. Go to step 3.

Look for a fault number concerning PCMs (see


411-9001-105 (Nortel GSM BSS Fault Clearing Advanced Maintenance Procedures)).

If an lapdLink object is "disabled-failed", the BSC is


concerned. Look for alarms concerning the BSC.

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 11.

Perform a "Display hardware configuration" command on the


btsSiteManager object: the results are displayed in the "Session
log" window.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

437

Look at the result displayed in the "Session log" window.

If the state of the "converter BCF" equipment is "failed", the


fault is confirmed. Go to step 3.

If the state of the "converter BCF" equipment is "working", the


fault is not confirmed. Go to step 10.

Fault location

The equipment number indicates which of the three power


supplies is concerned by the alarm. Go to step 4.

On-site maintenance

Check the mains power supply on the operator box.

If the mains power supply is correct, it is a PCM fault. Refer


to the fault number 1054 (see 411-9001-105 (Nortel GSM
BSS Fault Clearing - Advanced Maintenance Procedures) ).

If not, solve the problem concerning the mains power supply


and go to step 8.

Replace the BCF power supply (Field Replacement Unit).


Refer to 411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting).

If the alarm persists, go to step 6.

Replace the ALCO board (Field Replaceable Unit). Refer to


411-9001-048 (Nortel GSM BTS S8000/S8003 Troubleshooting).

If the alarm has disappeared, go to step 11.

If the alarm has disappeared, go to step 11.


If the alarm persists, go to step 7 for the S8000 Indoor BTS
or to step 8 for the S8000 Outdoor BTS.

Replace the external alarm cable (Shop Replaceable Unit). Go


to step 8.

Additional checks

Check the alarm state.

If the alarm has disappeared, go to step 11.


If the alarm persists, go to step 9.

Perform a "Display hardware configuration" command on the


btsSiteManager object: the results are displayed in the "Session
log" window.

If the BCF converter equipment is still "failed", call the


manufacturer.

If the BCF converter equipment is "working", go to step 10.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

438

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

10

Clear the alarm.

11

The procedure is complete.


--End--

2.12.9 BRC (source: Manual switch on battery power)


Fault number 1067

Abis event reporting a transient default

Equipment:

BRC

Source:

(6553601) Manual switch on battery power

BTS model:

S8000 CBCF Outdoor + S8002

FAULT ANALYSIS
This notification indicates that the BTS has been manually (using OMC-R
command) switched from main power to battery.

2.12.10 BRC (source: Automatic switch on battery power)


Fault number 1067

Abis event reporting a transient default

Equipment:

BRC

Source:

(6553602) Automatic switch on battery power

BTS model:

S8000 CBCF Outdoor + S8002

FAULT ANALYSIS
This notification indicates that the BTS has been automatically switched
from main power to battery.

2.12.11 BRC (source: Manual switch on main power)


Fault number 1067

Abis event reporting a transient default

Equipment:

BRC

Source:

(6553603) Manual switch on main power

BTS model:

S8000 CBCF Outdoor + S8002

FAULT ANALYSIS
This notification indicates that the BTS has been automatically switched
from battery to main power.

2.12.12 BRC (source: Automatic switch on main power)


Fault number 1067
Equipment:

Abis event reporting a transient default


BRC

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

Source:

(6553604) Automatic switch on main power

BTS model:

S8000 CBCF Outdoor + S8002

439

FAULT ANALYSIS
This notification indicates that the BTS has been automatically switched
from battery to main power.

2.12.13 BRC (source: Battery failure)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

BRC

Source:

(6553605) Battery failure

BTS model:

S8000 CBCF Outdoor + S8002

FAULT ANALYSIS
The software of the RECAL board in the BTS continuously controls the
state of the battery strings and generates a battery failure alarm to the
BCF when an error is detected on one of them. On switching the power
supply mode, the battery failure alarm is cleared and the control algorithm
is restarted.
The following two types of malfunction are covered:

When the battery is floating or loading:

The battery is considered "bad" when the middle point voltage of one
string gets out of a given range (+/- 1,3V). When the RECAL detects a
battery failure, the BCF generates a notification (fault number 1067). This
notification specifies a battery malfunction with the battery failure cause. A
discharge test is recommended to confirm the battery status. When the
battery is floating or loading, every 10 minutes the value is reported at the
BTS level, computed on average of values sampled every 100 ms.

The battery is in use (discharge)

After a short period of time (60 sec.), the middle point voltage of each
string is computed (average on values sampled every 100 ms) as a
reference. Then, the middle point voltage of each string is periodically
compared to this reference.
The battery is considered bad when the difference between the reference
and the middle point voltage goes outside of a given range (+/- 0,5V) And
the Stringglobal voltage is greater than a given threshold (45,5V) : in order
to avoid generating a battery failure notification in case of huge discharge
due to a main power failure (the variation of the difference between the
reference and the middle point voltage is therefore normal).

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

440

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

When the RECAL detects a battery failure, the BCF generates a


notification (fault number 1067). This notification specifies a battery
malfunction with the battery failure cause. Furthermore, the BTS does
not switch to main power and hence the discharge phase goes to the
threshold which triggers an automatic switch to the main power (processed
by the BRC).
When the battery is in use (discharge), every 2 seconds the value is
reported at the BTS level, computed on average of values sampled every
100 ms.
A string is composed of 4 stacks. A double failure in a string (a stack on
each side of the middle point voltage with the same decrease of voltage) is
not detected by this method since the middle point voltage remains in the
given range. However, the analysis of the voltage-time diagram allows the
detection a quick discharge which highlights a battery failure.
The battery malfunction alarm is cleared at the OMC-R on switching the
battery mode (main or battery). When the string is replaced, checks can
be done with the TIL (middle point voltage values, global string voltage
value) without having to wait for BTS detection which will be notified to the
OMC-R.

2.12.14 BRC (source: Monitored battery not present)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

BRC

Source:

(6553606) Monitored battery not present

BTS model:

S8000 CBCF Outdoor + S8002

FAULT ANALYSIS
When the BRC is not present (or does not work and is detected
as not present), a notification is sent by the BTS to the OMC-R
if the BRC features are activated in the set external contact (the
batteryRemoteControllerPresence parameter is set to present). By
default, this parameter is set to not present.
When the BRC led is ON, it means that the BTS is powered by batteries,
and that rectifiers are OFF (Note that the BRC led is turned ON only if
the user manually switches the BTS from mains to battery using OMC-R.
In case the mains circuit breaker is switched off the BTS automatically
switches to battery and the BRC led will not be turned ON in this case).
Hence, no maintenance is allowed on batteries. If maintenance is done,
then the BTS may be lost due to power shut down.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

441

2.12.15 BRC (source: Internal inconsistency)


Fault number 1067

Internal inconsistency

Equipment:

BRC

Source:

(6553607) Internal inconsistency

BTS model:

S8000 CBCF Outdoor + S8002

FAULT ANALYSIS
The notification 1067 (cause Detection of an internal inconsistency) can
be caused by cable P3 or any combination of P3 with another cable. A
lock/unlock on the BTS Site Manager is necessary for the maintenance.
Then, a "switch battery on/off" command from the OMC-R may be required
to switch the power mode to main supply or battery in accordance with
the customer choice.

2.12.16 BTS SYNCHRONIZATION (source: SYNO clock not locked on


the network)
Fault number 1067

Abis event reporting a hardware fault

Equipment:

BTS synchronization

Source:

(3342340) SYNO clock not locked on the network

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
A BTS works on its internal clock and provides the other BTSs with it
through the PCM links.
This alarm indicates a problem with the radio cabinet clock: the value
of the reference clock of the synchronizing PCM is not in the admitted
interval.

REACTION OF THE SYSTEM


BSC defense As long as the PCM link is operational, there is no BSC
defense action.
Impact on the service As long as the PCM link is operational, there is
no BSC defense action.

If the impact is "non transparent for the BSC" in the notification, the
BSC unconfigures the btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

442

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

CAUTION
Service interruption
The service is reduced or lost depending on the
configuration.

If the impact is "transparent for the BSC" in the notification, the BSC
does nothing.

CAUTION
Service interruption
A handover problem can occur between the BTS concerned
and its neighboring BTSs (a Nortel BTS or a BTS of another
manufacturer).

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

443

object to become "enabled", "disabled-dependency", or


"disabled-failed".
b.

As soon as the site is operational (the operationalState


of the btsSiteManager object will be "enabled"), check if
the alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 33.

On-site maintenance using the OMC-R

Check the number of impacted sites.

If only one site is impacted, go to step 3.


If several sites are impacted, go to step 4.

Check the validity of the alarm on the CMCF board by


performing a visual test of the board.

If the "LCKD" LED of the CMCF board is on and the "SKP"


LED of the CPCMI board is on, the fault is confirmed. Go to
step 5.

Otherwise, the fault is not confirmed. Go to step 30.

Check the validity of the alarm on several impacted sites by


performing a visual test of the board.

If the "LCKD" LED of the CMCF board is on and the "SKP"


LED of the CPCMI board is on, the fault is confirmed. Go to
step 11.

Otherwise, the fault is not confirmed. Go to step 30.

Perform a switchover of the CMCF board.


Check if the alarm persists in the "Current Alarm list" window.

If the alarm has disappeared, go to step 6.


If the alarm persists, go to step 7.

Replace the previously active CMCF board (Field Replaceable


Unit). Refer to:

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8000 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for


the S8002 BTS

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8003 BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for


the S8006 BTS

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

444

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Go to step 31.
7

Check the number of PCM links declared.

If there is only one PCM link declared, go to step 8.


If there are several PCM links declared, go to step 9.

Replace the CPCMI board (Field Replaceable Unit). Refer to:

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8000 BTS

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8003 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for


the S8002 BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for


the S8006 BTS

If the alarm has disappeared, go to step 33. Otherwise, call the


manufacturer.
9

Perform a "Display dynamic data" command on the lapdLink


object to determine which PCM link is used by the lapd.

10

Perform a switchover of the PCM links by setting the


administrativeState of the lapdLink object to "locked".

If the alarm has disappeared, go to step 8.


If the alarm persists, perform this action on each PCM link
again and as long as the alarm persists. At the end,
If the alarm has disappeared, go to step 8.
If the alarm persists, go to step 11.

11

12

Perform a "Display dynamic data" command on the bsc object to


determine which TCU gives the clock to the network.

If the "synchronizing PCM" parameter is "synchro internal


clock", go to step 29.

If the "synchronizing PCM" parameter is not "synchro internal


clock", go to step 12.

Check the number of available TCUs.

13

If there are at least two available TCUs, go to step 13.


If there is only one TCU, go to step 14.

Perform a PCM Ater link switchover by setting the


administrativeState of the pcmCircuit object to "locked".

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

14

445

If the alarm has disappeared, go to step 14.


If the alarm persists, go to step 20.

Perform a "Display all" command on the transcoder object:


to check the state of the TCU 3000.

15

If the operationalState of the transcoder object is "enabled",


the problem concerns the BSC 3000. Go to step 19.

If the operationalState of the transcoder object is "disabled",


the problem concerns the BSC. Go to step 20.

Measure the frequency of the PCM A downlinks (with a PCM


analyzer).

If the frequency is correct, measure the frequency of the PCM


A uplinks.
If the frequency is not correct on all the PCM A links, go
to step 16.
If the frequency is not correct on one of the PCM A links,
go to step 17.
If the frequency is correct, the problem does not concern
the TCU but concerns the BSC. Go to step 20.

16

If the frequency is not correct, the problem concerns the


MSC. Look for it and solve it. Then go to step 1.

Replace:

For the TCU 3000, the CEM board (Field Replaceable Unit).
Refer to Nortel GSM BSC 3000 / TCU 3000 Troubleshooting
(411-9001-132).
If the alarm has disappeared, go to step 32.
If the alarm persists, call the manufacturer.

17

Replace:

For the TCU 3000, the IEM board. Refer to Nortel GSM BSC
3000 / TCU 3000 Troubleshooting (411-9001-132).
If the alarm has disappeared, go to step 32.
If the alarm persists, call the manufacturer.

18

Perform a "Display all" command on the transcoder object to


check the state of the TCU.

If the operationalState of the transcoder object is "enabled",


the problem concerns the BSC. Go to step 20.

If the operationalState of the transcoder object is "disabled",


go to step 19.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

446

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

19

Perform a PCM A link switchover by setting the administrativeSta


te of the pcmCircuit object to "locked". Then perform a "Display
all" command on the transcoder object to check the state of the
TCU.

If the operationalState of the transcoder object is "enabled",


the problem concerns the IEM board of the TCU 3000. Go
to step 17.

If the operationalState of the transcoder object is "disabled",


do the same operation twice: either the operationalState
of the transcoder object becomes "enabled", or the
operationalState of the transcoder object remains "disabled".
If the operationalState is "enabled", go to step 15. Otherwise
go to step 17.

20

Perform a "Display all" command on the bsc object to check the


correctness of the parameters of the passive chain.

21

Perform one of the following:

22

23

For the BSC 3000, go to step 22.

Measure the frequency of the PCMs (with a PCM analyzer) on


the MSC side, on the BSC side and on the TCU side.

If the frequency of the PCM A link is correct and the


frequency of the PCM Ater link is correct, go to step 25.

If the frequency of the PCM A link is correct and the


frequency of the PCM Ater link is not correct, go to step 23.

If the frequency of the PCM A link is not correct, if it is the


downlink concerned, go to step 23, and if it is the uplink
concerned, go to step 23.

Replace the following items of equipment one after the other to


identify the faulty item.
a Replace the CEM board of the TCU 3000. Refer to Nortel
GSM BSC 3000/TCU 3000 Troubleshooting (411-9001-132).

If the alarm has disappeared, go to step 33.


If the alarm persists, go to step 23b

b Remove the newly inserted CEM board and reinsert the old
CEM board. Then replace the IEM board (Field Replaceable
Unit) of the TCU 3000. Refer to Nortel GSM BSC 3000/TCU
3000 Troubleshooting (411-9001-132).

24

If the alarm has disappeared, go to step 33.


If the alarm persists, call the manufacturer.

The problem concerns the MSC. Solve it and then go to step 1.


Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

25

447

Measure the frequency of the PCMs (with a PCM analyzer) on


the BSC side, on the TCU side and on the BTS side.

If the frequency of the PCM Abis link is correct and


the frequency of the PCM Ater link is correct, call the
transmission operator.

If the frequency of the PCM Abis link is not correct and the
frequency of the PCM Ater link is correct:
If it is the uplink concerned and if there is one BTS, go to
step 26.
If it is the uplink concerned and if there are several BTSs,
the problem concerns the PCMs. Call the transmission
operator.
If it is the downlink concerned, the problem concerns the
PCMs. Call the transmission operator.

If the frequency of the PCM Ater link is not correct:


If it is the uplink concerned, go to step 28.
If it is the downlink concerned, the problem concerns the
PCMs. Call the transmission operator.

26

Replace the CMCF board (Field Replaceable Unit). Refer to:

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8000 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for


the S8002 BTS

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8003 BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for


the S8006 BTS

If the alarm has disappeared, go to step 33. If the alarm persists,


go to step 27.
27

Replace the CPCMI board (Field Replaceable Unit). Refer to:

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8000 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for


the S8002 BTS

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8003 BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for


the S8006 BTS

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

448

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the alarm has disappeared, go to step 33. Otherwise, call the


manufacturer.
28

Replace:

For the BSC 3000, the CEM board (Field Replaceable Unit).
Refer to Nortel GSM BSC 3000 / TCU 3000 Troubleshooting
(411-9001-132).
If the alarm has disappeared, go to step 33.
If the alarm persists, call the manufacturer.

29

Make a TCU operational.


As soon as a TCU is operational, go to step 12.

Additional checks

30

Check the alarm state in the "Current Alarm list" window.

31

If the alarm has disappeared, go to step 33.


If the alarm persists, go to step 31.

Check the state of the alarm on the CMCF board by performing a


visual test of the board.

If the "LCKD" LED of the CMCF board is off and the "SKP"
LED of the CPCMI board is off, call the manufacturer.

Otherwise, go to step 32.

32

Clear the alarm.

33

The procedure is complete.


--End--

2.12.17 BTS synchronization (source: Synchro not locked because


OCVXO is KO)
Fault number 1067

Abis event reporting a hardware fault

Equipment:

BTS synchronization

Source:

(3342341) Synchro not locked because OCVXO is


KO

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
The begin-of-fault alarm indicates that the SYN clock is not able to lock on
the PCM because the OCVXO (oscillator) of the passive CMCF board is
faulty (the BTS is in duplex configuration).

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

449

The problem occurred either on the passive CMCF board, or on the


previously active CMCF board, which became passive after an automatic
switchover.
The end-of-fault must be manual.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
operational.

None, as long as the active CMCF board is

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled". If several faults occur on the BTS
Synchronization item of equipment, only the first generated
fault remains visible at the OMC-R. Other faults are available
in the notification logs.

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

450

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

object to become "enabled", "disabled-dependency", or


"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 6.

Check that the alarm on the BTS synchronization equipment of


the BTS is valid, by performing a "Display hardware information"
command (in "standard" mode) on the btsSiteManager object.
Look at the result displayed in the session log window.

If the BTS synchronization equipment is "failed", the fault is


confirmed. Go to step 3.

If the BTS synchronization equipment is "working", the fault is


not confirmed. Go to step 6.

On-site maintenance

Replace the passive CMCF board (Field Replaceable Unit). The


cause "OCVXO KO" can be indicated on the repair note. Refer
to:

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8000 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for


the S8002 BTS

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8003 BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for


the S8006 BTS

Then go to step 4.
Additional checks

Check the state of the alarm on the CMCF board by performing a


visual test of the board.

If the passive CMCF board is not operational, call the


manufacturer.

Otherwise, go to step 5.

Perform a "Display hardware information" command (in


"standard" mode) on the btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

451

Look at the result displayed in the session log window.

If the BTS synchronization equipment is still "failed", call the


manufacturer.

If the BTS synchronization equipment is "working", go to step


6.

Clear the alarm.

The procedure is complete.


--End--

2.12.18 BTS synchronization (source: GPS synchronization


unavailable)
Fault number 1067

Abis event reporting a hardware fault

Equipment:

BTS synchronization

Source:

(3342343) GPS synchronization unavailable

BTS model:

S8000 Outdoor CBCF + S8000 Indoor CBCF

FAULT ANALYSIS
The begin-of-fault alarm indicates that the GPS PPS signal is not present
or not correct, even though the GPS synchronization mode has been
selected at the OMC-R.
The end-of-fault alarm indicates that the GPS synchronization has been
retrieved again and that the BTS synchronized itself on it.
If GPS has become in service but is not accurate enough to be used
as a synchronization source, the end-of-fault "GPS synchronization
unavailable" is sent, and another alarm with begin-of-fault "Lack of GPS
synchronization accuracy" is sent too (refer to Paragraph 2.12.20 BTS
SYNCHRONIZATION (source: Lack of GPS synchronization accuracy)
(page 461)).

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service None when the BTS remains synchronized on
the Abis link (begin-of-fault).

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

452

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

However, when the BTS synchronizes itself on the external


synchronization, it changes its GSM time for the GPS time. This change
of GSM time causes a reset "GSM time modified" of all the TRXs
(end-of-fault).

CAUTION
Service interruption
The service is lost during the TRX reset.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled". If several faults occur on the BTS
Synchronization item of equipment, only the first generated
fault remains visible at the OMC-R. Other faults are available
in the notification logs.

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

453

object to become "enabled", "disabled-dependency", or


"disabled-failed".
b.

As soon as the site is operational (the operationalState


of the btsSiteManager object will be "enabled"), check if
the alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 13.

Check that the alarm on the BTS synchronization equipment of


the BTS is valid:
a Perform a "Display data information" command (in "normal"
mode) on the btsSiteManager object.
Look at the result displayed in the session log window.

The "Current synchronization mode" is: "Abis


synchronization due to GPS synchronization unavailable
or lack of accuracy".

The "Available synchronization sources" are: "Abis


synchronization only".

Go to step 2b.
b

Perform a "Display hardware information" command (in


"standard" mode) on the btsSiteManager object.
Look at the result displayed in the session log window.

If the BTS synchronization equipment is "failed", the fault


is confirmed. Go to step 3.

If the BTS synchronization equipment is "working", the


fault is not confirmed. Go to step 13.

On-site maintenance

On site, check the validity of the alarm by performing a visual


test of the synchronization LEDs on the CMCF boards.

When the GPS synchronization is unavailable, the BTS


remains synchronized through the Abis link, and the LEDs of
the CMCF boards are lit as shown in Table 12 "CMCF boards
LEDs status (BTS synchronized on Abis link)" (page 453).
Then the fault is confirmed.
Table 12
CMCF boards LEDs status (BTS synchronized on Abis link)
LEDs

Active CMCF board

Passive CMCF board

CLK 0, 1, 2

one of them is ON
(displaying the
PCM no. used for
synchronization)

one of them is ON
(displaying the
PCM no. used for
synchronization)

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

454

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Table 12
CMCF boards LEDs status (BTS synchronized on Abis link) (contd.)
LEDs

Active CMCF board

Passive CMCF board

LCKD

OFF

ON (solid green)

HLDVR

OFF

OFF

If the BTS is equipped with a TMU, go to step 4.


If the BTS is equipped with an LMU + EIU, go to step 5.
4

On site, check the validity of the alarm by performing a visual


test of the TMU.

If the TMU control LED is OFF, the TMU is not receiving


power. Check the TMU power connections (refer to the TMU
manufacturer documentation) or go to step 6.

If the TMU control LED is flashing green, the TMU is


initializing. Wait for the end of initializing, until the TMU is in a
stable state, such as solid green, flashing yellow or solid red.

If the TMU control LED is solid red, the GPS is out of service,
experiencing a major fault. Go to step 6.

If the TMU control LED is flashing yellow, the GPS is working


but the status of the synchronizing signal is not satisfactory
enough to use it as a synchronization source.
Wait for 30 minutes after the last TMU power up (time
needed to catch satellite signals and converge the
computation of position and time).
If the situation does not improve, check the antenna
connection (AMT connector on the TMU). If necessary,
refer to TMU manufacturer documentation.
If the situation does not improve, the GPS antenna
installation needs to be modified. Go to step 6.

If the TMU control LED is solid green, the GPS is working


and available as synchronization source. Go to step 7.

On site, check the validity of the alarm by performing a visual


test of the LMU + EIU:

If the EIU power LED is solid green, the EIU is receiving


power and sending the timing signal to the BTS. Go to step 8.

If the EIU power LED is off, the EIU is not receiving


power. Check the EIU power connections (refer to the EIU
manufacturer documentation) or go to step 6.

Call the TMU (or LMU + EIU) manufacturer.

Check the cable between the TMU and BCFICO board.


Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

455

Unplug the cable between the TMU (RJ45 "BTS" connector)


and BCFICO board (9-pin connector).

Plug the cable again between the TMU and BCFICO board.

Check that the three "CLK 0", "CLK 1" and "CLK 2" LEDs of
the CMCF board blink three times simultaneously for a period
of 2 seconds. Then go to step 9.

Check the cable between the LMU and EIU to the BTS. A Y
cable is used to connect:

the LMU RS-232 cable (ENV/AOA connector) on the one end

Unplug the Y cable.

Plug the Y cable again.

Check that the three "CLK 0", "CLK 1" and "CLK 2" LEDs of
the CMCF board blink three times simultaneously for a period
of 2 seconds. Then go to step 9.

the EIU RS-422 cable (RJ45 connector) on the other end


into the BTS (CBCF port RS-232)

Additional checks

Check the state of the LEDs on the CMCF boards.

If the GPS synchronization is available, the LEDs of the


CMCF boards are lit as shown in Table 13 "CMCF boards
LEDs status (BTS synchronized on GPS)" (page 455). Then
go to step 10.
Table 13
CMCF boards LEDs status (BTS synchronized on GPS)
LEDs
CLK 0, 1, 2
LCKD
HLDVR

10

Active CMCF board

Passive CMCF board

all ON (solid green)

all ON (solid green)

ON (solid green)

ON (solid green)

OFF

OFF

If the LEDs show that the BTS is still synchronized on the


Abis link (refer to Table 12 "CMCF boards LEDs status (BTS
synchronized on Abis link)" (page 453) in step 3), then go to
step 12.

Use the TIL to check that the cable has been correctly connected
and that the BTS receives the GPS synchronization signal.
Connect the TIL to the BTS:

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

456

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

11

If the TIL displays "GPS synchronization available", then the


BTS receives 1 Hz PPS clock and PPS frames. Go to step
11.

If the TIL displays "no external synchronization source", then


the BTS does not receive any GPS signal. Go to step 12.

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 13.


If the alarm persists, go to step 12.

12

Call the manufacturer.

13

The procedure is complete.


--End--

2.12.19 BTS synchronization (source: Loss of GPS synchronization)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

BTS synchronization

Source:

(3342344) Loss of GPS synchronization

BTS model:

S8000 Outdoor CBCF + S8000 Indoor CBCF

FAULT ANALYSIS
The begin-of-fault alarm indicates that the GPS PPS is no more present.
The BTS detects a loss of GPS synchronization signal when one of the
following events occurs:

when the GPS status = 2 (the GPS is out of service experiencing a


major fault. The TMU control LED is solid red)

when the PPS is not received or not correct

when the GPS time is not correctly incremented by 1 sec. at each PPS
period successively during 3 times

when the serial link between TMU and the BCFICO board is faulty
(CRC KO) or between the LMU and CBCF port

The end-of-fault alarm indicates that the GPS synchronization has been
retrieved again and that the BTS synchronized itself on it.

REACTION OF THE SYSTEM


BSC defense
None.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

Impact on the service


clock (begin-of-fault).

457

None because the BTS holds over to its internal

When the BTS synchronizes itself on the GPS synchronization, it changes


its GSM time for the GPS time without impact on the service (end-of-fault).

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled". If several faults occur on the BTS
Synchronization item of equipment, only the first generated
fault remains visible at the OMC-R. Other faults are available
in the notification logs.

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 14.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

458

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Check that the alarm on the BTS synchronization equipment of


the BTS is valid:
a Perform a "Display data information" command (in "normal"
mode) on the btsSiteManager object.
Look at the result displayed in the session log window.

The "Current synchronization mode" is: "hold over mode


due to a loss of GPS synchronization", and the "Available
synchronization sources" are: "Abis synchronization only".
Go to step 2b.

b Perform a "Display hardware information" command (in


"standard" mode) on the btsSiteManager object.
Look at the result displayed in the session log window.

If the BTS synchronization equipment is "failed", the fault


is confirmed. Go to step 3.

If the BTS synchronization equipment is "working", the


fault is not confirmed. Go to step 14.

On-site maintenance

On site, check the validity of the alarm by performing a visual


test of the synchronization LEDs on the CMCF boards.

When the GPS synchronization is lost, the BTS remains


synchronized on its internal clock, and the LEDs of the CMCF
boards are lit as shown in Table 14 "CMCF boards LEDs
status (BTS in holdover after loss of GPS synchro)" (page
458). Then the fault is confirmed.
Table 14
CMCF boards LEDs status (BTS in holdover after loss of GPS
synchro)
LEDs

Active CMCF board

Passive CMCF board

all ON

all ON

LCKD

OFF

ON

HLDVR

ON

ON

CLK 0, 1, 2

If the BTS is equipped with a TMU, go to step 4.


If the BTS is equipped with an LMU + EIU, go to step 5.
4

On site, check the validity of the alarm by performing a visual


test of the TMU.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

459

If the TMU control LED is solid red, the GPS is out of service,
experiencing a major fault. Go to step 6.

If the TMU control LED is flashing green, the TMU is


initializing. Wait for the end of initializing, until the TMU is in a
stable state, such as solid green, flashing yellow or solid red.

If the TMU control LED is flashing yellow, the GPS is working


but the status of the synchronizing signal is not satisfactory
enough to use it as a synchronization source.
Wait for 30 minutes after the last TMU power up (time
needed to catch satellite signals and converge the
computation of position and time).
If the situation does not improve, check the antenna
connection (AMT connector on the TMU). If necessary,
refer to TMU manufacturer documentation.
If the situation does not improve, the GPS antenna
installation needs to be modified. Go to step 6.

If the TMU control LED is solid green, the GPS is working


and available as synchronization source. Go to step 7.

On site, check the validity of the alarm by performing a visual


test of the LMU + EIU:

If the EIU power LED is solid green, the EIU is receiving


power and sending the timing signal to the BTS. Go to step 8.

If the EIU power LED is off, the EIU is not receiving


power. Check the EIU power connections (refer to the EIU
documentation) or go to step 6.

Call the TMU (or LMU + EIU) manufacturer.

Check the cable between the TMU and BCFICO board.


a Unplug the cable between the TMU and BCFICO board.
b Plug the cable again between the TMU and BCFICO board.
c Check that the three "CLK 0", "CLK 1" and "CLK 2" LEDs of
the CMCF board blink three times simultaneously for a period
of 2 seconds. Then go to step 9.

Check the cables between the LMU and EIU to the BTS. A Y
cable is used to connect:

The LMU RS-232 cable (ENV/AOA connector) on the one


end

The EIU RS-422 cable (RJ45 connector) on the other end


Into the BTS (CBCF port RS-232)

a Unplug the Y cable.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

460

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

b Plug the Y cable again.


c Check that the three "CLK 0", "CLK 1" and "CLK 2" LEDs of
the CMCF board blink three times simultaneously for a period
of 2 seconds when the cable is correctly connected. Then go
to step 9.
Additional checks

Check that the BTS is getting resynchronized on the GPS clock:


a The BTS can detect a correct GPS signal three seconds after
the cable (between the BTS and the LMU or TMU) has been
plugged. Note that, at this stage, a "Display data information"
command (in "normal" mode) on the btsSiteManager object
gives the following items of information:

The "Current synchronization mode" is: "hold over mode


due to a loss of GPS synchronization".

The "Available synchronization sources" are: "Abis + GPS


synchronization".

b Wait until the BTS is completely synchronized on the GPS


clock. It can take some time, depending on how long the
GPS signal has been unavailable.
c When the BTS is completely synchronized on the GPS
clock, the end-of-fault alarm (cause 3342344 "Loss of GPS
synchronization") is sent at the OMC-R.
d Another "Display data information" command (in "normal"
mode) on the btsSiteManager object now gives the following
items of information:

The "Current synchronization mode" is: "Network GPS


synchronized".

The "Available synchronization sources" are: "Abis + GPS


synchronization".

e Go to step 10.
10

Check the state of the LEDs on the CMCF boards.

If the GPS synchronization is available, the LEDs of the


CMCF boards are lit as shown in Table 15 "CMCF boards
LEDs status (BTS synchronized on GPS)" (page 460). Then
go to step 11.
Table 15
CMCF boards LEDs status (BTS synchronized on GPS)
LEDs

Active CMCF board

Passive CMCF board

CLK 0, 1, 2

all ON

all ON

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

461

Table 15
CMCF boards LEDs status (BTS synchronized on GPS) (contd.)
LEDs

11

Active CMCF board

Passive CMCF board

LCKD

ON

ON

HLDVR

OFF

OFF

If the LEDs show that the BTS is still synchronized on its


internal clock (refer to Table 14 "CMCF boards LEDs status
(BTS in holdover after loss of GPS synchro)" (page 458) in
step 3), then go to step 13.

Use the TIL to check that the cable has been correctly connected
and that the BTS receives the GPS synchronization signal.
Connect the TIL to the BTS:

12

If the TIL displays "GPS synchronization available", then the


BTS receives 1 Hz PPS clock and PPS frames. Go to step
12.

If the TIL displays "no external synchronization source", then


the BTS does not receive any GPS signal. Go to step 13.

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 14.


If the alarm persists, go to step 13.

13

Call the manufacturer.

14

The procedure is complete.


--End--

2.12.20 BTS SYNCHRONIZATION (source: Lack of GPS synchronization


accuracy)
Fault number 1067

Abis event reporting a hardware fault

Equipment:

BTS synchronization

Source:

(3342345) Lack of GPS synchronization accuracy

BTS model:

S8000 Outdoor CBCF + S8000 Indoor CBCF

FAULT ANALYSIS
The begin-of-fault alarm indicates that the timing quality is not sufficient.
The GPS signal is not accurate enough to be used as a synchronization
source. The BTS detects a loss of accuracy when the GPS status goes
from 0 to 1. The GPS is working but the status of the synchronizing signal
is not satisfactory enough to use it as a synchronization source.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

462

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

When the BTS has just been powered up, if the TMU is powered through
the BTS itself, several minutes are needed before the GPS receivers
become active (TMU (or LMU + EIU) being correctly locked and suitable
for BTS synchronization). This begin-of-fault alarm is sent in between.
Otherwise, the probable cause of the alarm is either a problem with the
GPS antenna, or the cable between the antenna and the TMU (or LMU
+ EIU).
The end-of-fault alarm indicates that the GPS PPS has become valid again
and that the BTS synchronized itself on it.

REACTION OF THE SYSTEM


BSC defense
None.

1st case: the GPS signal used to be accurate, and the BTS was
synchronized on it. But it has now become inaccurate, and as a
consequence the BTS has turned into holdover mode and sent the
alarm "Lack of GPS synchronization accuracy" without impact on the
service (begin-of-fault).
When the GPS PPS becomes valid again, the BTS synchronizes itself
on the GPS time without impact on the service (end-of-fault).

2nd case: The BTS has just started up (holdover mode, then
synchronized on the Abis link, followed by the BSC configuration).
But the GPS signal currently lacks accuracy. As a consequence, the
BTS remained synchronized on the Abis link and has sent the alarm
"Lack of GPS synchronization accuracy" without impact on the service
(begin-of-fault).
But when the GPS PPS becomes valid again, the BTS synchronizes
itself on the GPS time. This change of GSM time causes a reset
"GSM time modified" of all the TRXs with an impact on the service
(end-of-fault).

CAUTION
Service interruption
The service is lost during the TRX reset.

TROUBLESHOOTING
Step

Action

Preliminary checks

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

463

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled". If several faults occur on the BTS
Synchronization item of equipment, only the first generated
fault remains visible at the OMC-R. Other faults are available
in the notification logs.

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 11.

Check that the alarm on the BTS synchronization equipment of


the BTS is valid:
a Perform a "Display data information" command (in "normal"
mode) on the btsSiteManager object.
Look at the result displayed in the session log window.

The "Current synchronization mode" is: "hold over mode


due to a GPS synchronization lack of accuracy".

The "Available synchronization sources" are: "Abis + GPS


synchronization".

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

464

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Go to step 2b.
b Perform a "Display hardware information" command (in
"standard" mode) on the btsSiteManager object.
Look at the result displayed in the session log window.

If the BTS synchronization equipment is "failed", the fault is


confirmed. Go to step 3.

If the BTS synchronization equipment is "working", the fault is


not confirmed. Go to step 11.

On-site maintenance

On site, check the validity of the alarm by performing a visual


test of the synchronization LEDs on the CMCF boards. There
are two different cases:

1st case: the GPS signal used to be accurate, and the BTS
was synchronized on it. But it has now become inaccurate,
and the BTS has turned into holdover mode and sent the
alarm "Lack of GPS synchronization accuracy". The LEDs of
the CMCF boards are lit as shown in Table 16 "CMCF boards
LEDs status (BTS in holdover when the GPS synchro lacks
accuracy)" (page 464). The fault is confirmed:
If the BTS is equipped with a TMU, go to step 4.
If the BTS is equipped with an LMU + EIU, go to step 5.
Table 16
CMCF boards LEDs status (BTS in holdover when the GPS
synchro lacks accuracy)

LEDs

Active CMCF board

Passive CMCF board

CLK 0, 1, 2

all ON

all ON

LCKD

OFF

ON

HLDVR

ON

ON

2nd case: the BTS has just started up (holdover mode,


then synchronization on the Abis link, followed by the BSC
configuration). But the GPS signal currently lacks accuracy.
As a consequence, the BTS remained synchronized
on the Abis link and has sent the alarm "Lack of GPS
synchronization accuracy". The LEDs of the CMCF boards
are lit as shown in Table 17 "CMCF boards LEDs status
(BTS synchronized on Abis link)" (page 465). The fault is
confirmed. Note that there will be an impact on the service
at the end-of-fault.
If the BTS is equipped with a TMU, go to step 4.
If the BTS is equipped with an LMU + EIU, go to step 5.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

465

Table 17
CMCF boards LEDs status (BTS synchronized on Abis link)

LEDs

Active CMCF board

Passive CMCF board

CLK 0, 1, 2

one of them is ON
(displaying the PCM no.
used for synchronization)

one of them is ON
(displaying the PCM no.
used for synchronization)

LCKD

OFF

ON

HLDVR

OFF

OFF

On site, check the validity of the alarm by performing a visual


test of the TMU.

If the TMU control LED is solid red, the GPS is out of service,
experiencing a major fault. This is very unlikely because
this is not consistent with the current alarm "Lack of GPS
synchronization accuracy". Go to step 6.

If the TMU control LED is flashing green, the TMU is


initializing. Wait for the end of initializing, until the TMU is in a
stable state, such as solid green, flashing yellow or solid red.

If the TMU control LED is flashing yellow, the GPS is working


but the status of the synchronizing signal is not satisfactory
enough to use it as a synchronization source.
Wait for 30 minutes after the last TMU power up (time
needed to catch satellite signals and converge the
computation of position and time).
If the situation does not improve, check the antenna
connection (AMT connector on the TMU). If necessary,
refer to TMU manufacturer documentation.
If the situation does not improve, the GPS antenna
installation needs to be modified. Go to step 6.

On site, check the validity of the alarm by performing a visual


test of the LMU +EIU:

If the TMU control LED is solid green, the GPS is working


and available as synchronization source. Go to step 7.

If the EIU power LED is solid green, the EIU is receiving


power and sending the timing signal to the BTS. Go to step 7.

Call the TMU (or LMU + EIU) manufacturer.

Additional checks

Check the state of the LEDs on the CMCF boards.

If the GPS synchronization is accurate, the LEDs of the


CMCF boards are lit as shown in Table 18 "CMCF boards
LEDs status (BTS synchronized on GPS)" (page 466). Then
go to step 8.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

466

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers


Table 18
CMCF boards LEDs status (BTS synchronized on GPS)
LEDs

Active CMCF board

Passive CMCF board

all ON

all ON

LCKD

ON

ON

HLDVR

OFF

OFF

CLK 0, 1, 2

If the LEDs show that the BTS is still in holdover mode (refer
to Table 16 "CMCF boards LEDs status (BTS in holdover
when the GPS synchro lacks accuracy)" (page 464)) or is
synchronized on the Abis link (refer to Table 17 "CMCF
boards LEDs status (BTS synchronized on Abis link)" (page
465)), then go to step 10.

Use the TIL to check that the cable has been correctly connected
and that the BTS receives the GPS synchronization signal.
Connect the TIL to the BTS:

If the TIL displays "GPS synchronization available", then the


BTS receives 1 Hz PPS clock and PPS frames. Go to step 9.

If the TIL displays "no external synchronization source", then


the BTS does not receive any GPS signal. Go to step 10.

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 11.


If the alarm persists, go to step 10.

10

Call the BTS manufacturer.

11

The procedure is complete.


--End--

2.12.21 BTS SYNCHRONIZATION (source: Master synchronization


unavailable)
Fault number 1067

Abis event reporting a hardware fault

Equipment:

BTS synchronization

Source:

(3342346) Master synchronization unavailable

BTS model:

S8000 Outdoor CBCF + S8000 Indoor CBCF

FAULT ANALYSIS
The begin-of-fault alarm indicates that the slave BTS could not
synchronize itself on the master synchronizing BTS.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

467

The slave BTS received the set external contact message in "slave" mode,
and checked if the external synchronization signal (both 8 kHz and GSM
time) was present, but it was not. As a consequence, the BTS remained
synchronized on the BSC through the Abis link.
The end-of-fault alarm indicates that the external signal (both 8 kHz
and GSM time) has become available again and that the slave BTS
synchronized itself on it.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service None when the slave BTS remains synchronized
on the Abis link (begin-of-fault).
However, when the slave BTS synchronizes itself on the external
synchronization, it changes its GSM time for the master GSM time. This
change of GSM time causes a reset "GSM time modified" of all the TRXs
(end-of-fault).

CAUTION
Service interruption
The service is lost during the TRX reset.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

468

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled". If several faults occur on the BTS
Synchronization item of equipment, only the first generated
fault remains visible at the OMC-R. Other faults are available
in the notification logs.

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 11.

Check that the alarm on the BTS synchronization equipment of


the BTS is valid:
a Perform a "Display data information" command (in "normal"
mode) on the btsSiteManager object.
Look at the result displayed in the session log window.

The "Current synchronization mode" is: "Abis


synchronization due to master synchronization not
available".

The "Available synchronization sources" is: "Abis


synchronization only".

Go to step 2b.
b Perform a "Display hardware information" command (in
"standard" mode) on the btsSiteManager object.
Look at the result displayed in the session log window.

If the BTS synchronization equipment is "failed", the fault


is confirmed. Go to step 3.

If the BTS synchronization equipment is "working", the


fault is not confirmed. Go to step 11.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

469

On-site maintenance using the OMC-R

At the OMC-R, check the state of the master synchronizing


BTS. The master BTS must be powered on, to make the
synchronization feature available.

If the master BTS is powered off, go to step 5.


If the master BTS is powered on, go to step 4.

On site, check the validity of the alarm by performing a visual


test of the synchronization LEDs of the CMCF boards of the
slave BTS.

When the external synchronization is unavailable, the BTS


remains synchronized through the Abis link, and the LEDs of
the CMCF boards are lit as shown in Table 19 "CMCF boards
LEDs status (slave BTS synchronized on the Abis link)" (page
469). Then the fault is confirmed. Go to step 6.

Table 19
CMCF boards LEDs status (slave BTS synchronized on the Abis
link)
LEDs

Active CMCF board

Passive CMCF board

one of them is ON
(displaying the
PCM no. used for
synchronization)

one of them is ON
(displaying the PCM no.
used for synchronization)

LCKD

OFF

ON

HLDVR

OFF

OFF

CLK 0, 1, 2

On site, perform a visual test of the master BTS:

If the master BTS is powered off, power it on. If necessary


refer to 411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting). Then go to step 7.

If the master BTS is powered on, go to step 6.

Check the Y cable between the master and the slave BTS.
The Y cable is a shunt of the PCM between the main and
extension cabinets of the master BTS. It is connected to the
BCFICO board in the main cabinet of the slave BTS, thanks to
two connectors: the master 8 kHz SY is received on the RS232
connector, and the master GSM time is received on the PCM4/5
connector.
a Check the connections to the master BTS, as well as the
whole cable itself (there can be adaptors).
b Unplug the external SY and GSM time connectors on the
slave BTS.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

470

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

c Plug again the external SY and GSM time connectors on the


slave BTS.
d Check that the slave BTS synchronization LEDs "CLK 0",
"CLK 1" and "CLK 2" (on the CMCF board) blink three times
simultaneously for a period of 2 seconds.
e Check that the TRX reset (their LEDs blink until they are
operational again).

CAUTION
Service interruption
The service is lost during the TRX reset.

Connect the TIL to the slave BTS and check this BTS
receives the external synchronization signal coming from the
master BTS.

the TIL displays "master BTS synchronization available"


when the slave BTS receives 8 kHz clock and GSM time
on its external synchronization connectors. Then go to
step 7.

the TIL displays "no external synchronization source"


when the slave BTS does not receive 8 kHz clock or GSM
time on its external synchronization connectors. Then go
to step 10.

Additional checks

Check the state of the LEDs of the CMCF boards of the slave
synchronized BTS:

If the external synchronization is available, the LEDs of the


CMCF boards are lit as shown in Table 20 "CMCF boards
LEDs status (slave BTS fully synchro on its master BTS)"
(page 470). Then go to step 8.
Table 20
CMCF boards LEDs status (slave BTS fully synchro on its
master BTS)
LEDs

Active CMCF board

Passive CMCF board

all ON

all ON

LCKD

ON

ON

HLDVR

OFF

OFF

CLK 0, 1, 2

If the LEDs show that the slave BTS is still synchronized on


the Abis link (refer to Table 19 "CMCF boards LEDs status
(slave BTS synchronized on the Abis link)" (page 469) in step
4), then go to step 10.

Check the state of the site:


Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

471

a Perform a "Display data information" command (in "normal"


mode) on the btsSiteManager object.
Look at the result displayed in the session log window.

The "Current synchronization mode" is: "slave BTS


correctly synchronized on master signal".

The "Available synchronization sources" are: "Abis +


external synchronization coming from a master BTS".

Go to step 8b.
b Perform a "Display hardware information" command (in
"standard" mode) on the btsSiteManager object.
Look at the result displayed in the session log window.

The BTS synchronization equipment is "working", go to


step 9.

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 11.


If the alarm persists, go to step 10.

10

Call the manufacturer.

11

The procedure is complete.


--End--

2.12.22 BTS SYNCHRONIZATION (source: Loss of master GSM time)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

BTS synchronization

Source:

(3342347) Loss of master GSM time

BTS model:

S8000 Outdoor CBCF + S8000 Indoor CBCF

FAULT ANALYSIS
The begin-of-fault alarm indicates that the slave BTS lost its external GSM
time signal from the master synchronizing BTS.
As a consequence, the BTS remains synchronized on the master 8 kHz
SY signal. The GSM time sent to the TRX is the one calculated by the
BTS from the last one received from master BTS. There is no break on
GSM time, the TRX still work. The slave GSM time is calculated with the
same rate as the master BTS.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

472

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

The end-of-fault alarm indicates that the GSM time has become available
again and that the slave BTS synchronized itself on it.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service None when the slave BTS remains synchronized
on the master 8 kHz SY signal (begin-of-fault).
The slave BTS uses the SY signal as a synchronization source on
condition that no alarm with cause "Loss of master SY" has been sent at
the same time.
If both alarms are present simultaneously, first process the alarm with
cause "Loss of master SY".
However, in the very unlikely event that there is a GSM time break
(between the one received from the master BTS and the last one
calculated by the BCF and sent to the TRX), this break of GSM time
causes a reset "GSM time modified" of all the TRX (end-of-fault).

CAUTION
Service interruption
The service is lost if the TRX reset.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

473

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 7.

Check that the alarm on the BTS synchronization equipment of


the BTS is valid:
a Perform a "Display data information" command (in "normal"
mode) on the btsSiteManager object.
Look at the result displayed in the session log window.

The "Current synchronization mode" is: "slave BTS


synchronized on master SY but master GSM time has
been lost".

The "Available synchronization sources" is: "Abis


synchronization only".

Go to step 2b.
b Perform a "Display hardware information" command (in
"standard" mode) on the btsSiteManager object.
Look at the result displayed in the session log window.

If the BTS synchronization equipment is "failed", the fault


is confirmed. Go to step 3.

If the BTS synchronization equipment is "working", the


fault is not confirmed. Go to step 7.

On-site maintenance using the OMC-R

Check the Y cable between the master and the slave BTS.
The Y cable is a shunt of the PCM between the main and
extension cabinets of the master BTS. It is connected to the
BCFICO board in the main cabinet of the slave BTS, thanks to
two connectors: the master 8 kHz SY is received on the RS232
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

474

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

connector, and the master GSM time is received on the PCM4/5


connector. The alarm "Loss of master GSM time" can be due to
the GSM time connector being badly plugged.
a Check the connections to the master BTS, as well as the
whole cable itself (there can be adaptors).
b Unplug the GSM time connector on the slave BTS.
c Plug again the GSM time connector on the slave BTS.
d Check that the slave BTS synchronization LEDs "CLK 0",
"CLK 1" and "CLK 2" (on the CMCF board) blink three times
simultaneously for a period of 2 seconds.
e Connect the TIL to the slave BTS and check this BTS
receives the external synchronization signal coming from the
master BTS.

The TIL displays "master BTS synchronization available"


when the slave BTS receives 8 kHz clock and GSM time
on its external synchronization connectors. Then go to
step 4.

The TIL displays "no external synchronization source"


when the slave BTS does not receive 8 kHz clock or GSM
time on its external synchronization connectors. Then go
to step 6.

Additional checks

Check the state of the LEDs of the CMCF boards of the slave
synchronized BTS:

If the slave BTS is synchronized on its master BTS, the LEDs


of the CMCF boards are lit as shown in Table 21 "CMCF
boards LEDs status (slave BTS fully synchro on its master
BTS)" (page 474). Go to step 5.
Table 21
CMCF boards LEDs status (slave BTS fully synchro on its
master BTS)
LEDs

Active CMCF board

Passive CMCF board

all ON

all ON

LCKD

ON

ON

HLDVR

OFF

OFF

CLK 0, 1, 2

If not, go to step 6.

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 7.


If the alarm persists, go to step 6.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

Call the manufacturer.

The procedure is complete.

475

--End--

2.12.23 BTS SYNCHRONIZATION (source: Loss of master SY)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

BTS synchronization

Source:

(3342348) Loss of master SY

BTS model:

S8000 Outdoor CBCF + S8000 Indoor CBCF

FAULT ANALYSIS
The begin-of-fault alarm indicates that the slave BTS lost its external 8 kHz
SY signal from the master synchronizing BTS.
As a consequence, the BTS synchronizes itself on Abis link (to avoid a
drift of the GSM time if the loss of external synchronization goes on for
long). The GSM time sent to the TRX is the one calculated by the BTS
from the last one received from master BTS, even if the master GSM time
is still available. There is no break on GSM time, the TRX still work but the
synchronization with master BTS is not guaranteed anymore.
The end-of-fault alarm indicates that the external 8 kHz SY signal has
become available again, and that the BTS has resynchronized itself on it.

If the master GSM time is available, the slave BTS uses it.
If not, the BTS carries on calculating its GSM time and sends an
alarm with fault number 1067 source "Loss of master GSM time" (see
Paragraph 2.12.22 BTS SYNCHRONIZATION (source: Loss of master
GSM time) (page 471)).

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service None when the slave BTS remains synchronized
on the Abis link (begin-of-fault).
However, in the very unlikely event that there is a GSM time break
(between the one received from the master BTS and the last one
calculated by the BCF and sent to the TRX), this break of GSM time
causes a reset "GSM time modified" of all the TRXs (end-of-fault).
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

476

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

CAUTION
Service interruption
The service is lost if the TRX reset.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 10.

Check that the alarm on the BTS synchronization equipment of


the BTS is valid:

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

477

a Perform a "Display data information" command (in "normal"


mode) on the btsSiteManager object.
Look at the result displayed in the session log window.

The "Current synchronization mode" is: "Abis


synchronization due to loss of master SY".

The "Available synchronization sources" is: "Abis


synchronization only".

Go to step 2b.
b Perform a "Display hardware information" command (in
"standard" mode) on the btsSiteManager object.
Look at the result displayed in the session log window.

If the BTS synchronization equipment is "failed", the fault


is confirmed. Go to step 3.

If the BTS synchronization equipment is "working", the


fault is not confirmed. Go to step 10.

On-site maintenance using the OMC-R

At the OMC-R, check the state of the master synchronizing


BTS. The master BTS must be powered on, to make the
synchronization feature available.

If the master BTS is powered off, go to step 5.


If the master BTS is powered on, go to step 4.

On site, check the validity of the alarm by performing a visual


test of the synchronization LEDs on the CMCF boards of the
slave BTS.

If the external synchronization (8 kHz) is lost, the BTS


remains synchronized through the Abis link, and the LEDs of
the CMCF boards are lit as shown in Table 22 "CMCF boards
LEDs status (slave BTS synchronized on Abis link)" (page
477). Then the fault is confirmed. Go to step 6.

Table 22
CMCF boards LEDs status (slave BTS synchronized on Abis link)

LEDs

Active CMCF board

Passive CMCF board

CLK 0, 1, 2

one of them is ON
(displaying the PCM no.
used for synchronization)

one of them is ON
(displaying the PCM no.
used for synchronization)

LCKD

OFF

ON

HLDVR

OFF

OFF

On site, perform a visual test of the master BTS:

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

478

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the master BTS is powered off, power it on. If necessary


refer to 411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting). Then go to step 7.

If the master BTS is powered on, go to step 6.

Check the Y cable between the master and the slave BTS.
The Y cable is a shunt of the PCM between the main and
extension cabinets of the master BTS. It is connected to the
BCFICO board in the main cabinet of the slave BTS, thanks to
two connectors: the master 8 kHz SY is received on the RS232
connector, and the master GSM time is received on the PCM4/5
connector. The alarm "Loss of master SY" can be due to the SY
connector being badly plugged.
a Check the connections to the master BTS, as well as the
whole cable itself (there can be adaptors).
b Unplug the SY connector on the slave BTS.
c Plug again the SY connector on the slave BTS.
d Check that the slave BTS synchronization LEDs "CLK 0",
"CLK 1" and "CLK 2" (on the CMCF board) blink three times
simultaneously for a period of 2 seconds.
e Connect the TIL to the slave BTS and check this BTS
receives external synchronization signal coming from the
master BTS.

the TIL displays "master BTS synchronization available"


when the slave BTS receives 8 kHz clock and GSM time
on its external synchronization connectors. Then go to
step 7.

the TIL displays "no external synchronization source"


when the slave BTS does not receive 8 kHz clock or GSM
time on its external synchronization connectors. Then go
to step 9.

Additional checks

Check the state of the LEDs of the CMCF boards of the slave
synchronized BTS:

If the external synchronization is available, the LEDs of the


CMCF boards are lit as shown in Table 23 "CMCF boards
LEDs status (slave BTS fully synchro on its master BTS)"
(page 478). Then go to step 8.
Table 23
CMCF boards LEDs status (slave BTS fully synchro on its
master BTS)
LEDs
CLK 0, 1, 2

Active CMCF board

Passive CMCF board

all ON

all ON

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

479

Table 23
CMCF boards LEDs status (slave BTS fully synchro on its master BTS)
(contd.)
LEDs

Active CMCF board

Passive CMCF board

LCKD

ON

ON

HLDVR

OFF

OFF

If the LEDs show that the slave BTS is still synchronized


through the Abis link (refer to Table 22 "CMCF boards LEDs
status (slave BTS synchronized on Abis link)" (page 477) in
step 4), then go to step 9.

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 10.


If the alarm persists, go to step 9.

Call the manufacturer.

10

The procedure is complete.


--End--

2.12.24 Cabinet door (source: Door contact detection)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

door contact

Source:

(5898241) Door contact detection

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
This alarm is detected by the RECAL board.
This alarm indicates that the CBCF cabinet door has been opened
(begin-of-fault) or closed (end-of-fault).

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service

There is no immediate impact.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

480

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

CAUTION
Working instructions
If an intervention is being performed on the CBCF cabinet, the
door is open. Therefore, the alarm is normal.
However, if no intervention is being performed on the CBCF
cabinet, this alarm is not normal. Intervention on the site must
be immediate. If the doors remain open, temperature problems
could appear.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed" and process the
problem in order that the btsSiteManager object becomes
"enabled".
If no object is concerned and if a fault number 1054 (loss
of layer 2) has appeared:

If the cabinet is out of order, process the problem on


the cabinet. Go to step 3.

Otherwise, refer to the fault number 1054 (see


411-9001-105 (Nortel GSM BSS Fault Clearing Advanced Maintenance Procedures)).

If a pcmCircuit object is "disabled-failed":

If the cabinet is out of order, process the problem on


the cabinet. Go to step 3.

Look for a fault number concerning PCMs (see


411-9001-105 (Nortel GSM BSS Fault Clearing Advanced Maintenance Procedures)).

If an lapdLink object is "disabled-failed", the BSC is


concerned. Look for alarms concerning the BSC.

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

481

process the problem in order that the btsSiteManager object


becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 15.

Check that the alarm on the door contact is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "door contact" equipment is "failed", the


fault is confirmed. Go to step 4.

If the state of the "door contact" equipment is "working", the


fault is not confirmed. Go to step 14.

On-site maintenance

Check the state of the mains power supply on the operator box.

If the mains power supply is correct, it is a PCM fault. Refer


to fault number 1054 (see 411-9001-105 (Nortel GSM BSS
Fault Clearing - Advanced Maintenance Procedures)).

If not, solve the problem concerning the mains power supply


and go to step 12.

If the alarm appears but the door is closed, go to step 5.


Otherwise, go to step 14.

Check the door contact switch.

If it is correct, go to step 8.
If it is not correct, replace it. Then go to step 6.

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 15.


If the alarm persists, go to step 7.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

482

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Check the state of the door contact by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "door contact" equipment is still "failed", go


to step 8.

If the state of the "door contact" equipment is "working", go


to step 14.

Check the cable between the door contact and the RECAL
board.

If it is not correct, replace it (Shop Replaceable Unit). Go to


step 9.

Check the alarm state in the "Current Alarm list" window.

10

If it is correct, go to step 11.

If the alarm has disappeared, go to step 15.


If the alarm persists, go to step 10.

Check the state of the door contact by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

11

If the state of the "door contact" equipment is still "failed", go


to step 11.

If the state of the "door contact" equipment is "working", go


to step 14.

Replace the RECAL board (Field Replaceable Units). Refer to


411-9001-048 (Nortel GSM BTS S8000/S8003 Troubleshooting).
Go to step 12.

Additional checks

12

Check the alarm state in the "Current Alarm list" window.

13

If the alarm has disappeared, go to step 15.


If the alarm persists, go to step 13.

Check the state of the door contact by performing the "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "door contact" equipment is still "failed", call


the manufacturer.

If the state of the "door contact" equipment is "working", go


to step 14.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

14

Clear the alarm.

15

The procedure is complete.

483

--End--

2.12.25 Cavity (source: Cavity out of service)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

Cavity

Source:

(8388609) Cavity out of service

BTS model:

S8000 Indoor

FAULT ANALYSIS
This alarm indicates that the cavity is unusable.

REACTION OF THE SYSTEM


BSC defense The BSC unconfigures the transceiverEquipment object
concerned.
Impact on the service

One TRX becomes unavailable.

CAUTION
Service reduction
The service is reduced.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

484

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 7.

Check that the alarm on the cavity equipment is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "cavity" equipment is "failed", the fault is


confirmed. Go to step 3.

If the state of the "cavity" equipment is "working", the fault is


not confirmed. Go to step 6.

On-site maintenance

Replace the combiner (Field Replaceable Unit). Refer to


411-9001-048 (Nortel GSM BTS S8000/S8003 Troubleshooting).
Go to step 4.

Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 7.


If the alarm persists, go to step 5.

Check the state of the combiner by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "cavity" equipment is still "failed", call the


manufacturer.

If the state of the "cavity" equipment is "working", go to step


6.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

Clear the alarm.

The procedure is complete.

485

--End--

2.12.26 Cavity (source: Cavity parked after tuning fault (min not found))
Fault number 1067

Abis event reporting a hardware fault

Equipment:

cavity

Source:

(8388610) Cavity parked after tuning fault (min not


found)

BTS model:

S8000 Indoor

FAULT ANALYSIS
This alarm indicates that the cavity is no longer settled on its configuration
frequency.

REACTION OF THE SYSTEM


BSC defense The BSC unconfigures the transceiverEquipment
object concerned. It reconfigures the transceiver object on another
transceiverEquipment object, if the TDMA is priority.

CAUTION
Service reduction
The service is reduced.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

486

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

GSM BSS Fault Clearing - Advanced Maintenance


Procedures)).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 5.

Check that the alarm on the cavity equipment is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "cavity" equipment is "failed", the fault is


confirmed. Go to step 3.

If the state of the "cavity" equipment is "working", the fault is


not confirmed. Go to step 5.

Maintenance at the OMC-R

Lock the transceiverEquipment object in order to trigger a new


tuning.

Unlock the transceiverEquipment object.

If the problem has disappeared, go to step 5.


If the problem persists after several attempts, an on-site
intervention is necessary to locate the problem.

The procedure is complete.


--End--

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

487

2.12.27 Cavity (source: Loss of cavity initialization)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

Cavity

Source:

(8388611) Loss of cavity initialization

BTS model:

S8000 Indoor

FAULT ANALYSIS
This alarm indicates that the grading of the cavity has not been performed.

REACTION OF THE SYSTEM


BSC defense The BSC unconfigures the transceiverEquipment object
concerned.
Impact on the service

One TRX becomes unavailable.

CAUTION
Service reduction
The service is reduced.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

488

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

process the problem in order that the btsSiteManager object


becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 7.

Check that the alarm on the cavity is valid, by performing


a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "cavity" equipment is "failed", the fault is


confirmed. Go to step 3.

If the state of the "cavity" equipment is "working", the fault is


not confirmed. Go to step 6.

On-site maintenance

Replace the combiner (Field Replaceable Unit). Refer to


411-9001-048 (Nortel GSM BTS S8000/S8003 Troubleshooting).
Go to step 4.

Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 7.


If the alarm persists, go to step 5.

Check the state of the combiner by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "cavity" equipment is still "failed", call the


manufacturer.

If the state of the "cavity" equipment is "working", go to step


6.

Clear the alarm.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

489

The procedure is complete.


--End--

2.12.28 Cavity (source: Nack answer from cavity)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

Cavity

Source:

(8388612) Nack answer from cavity

BTS model:

S8000 Indoor

FAULT ANALYSIS
This alarm indicates that the cavity no longer responds.

REACTION OF THE SYSTEM


BSC defense The BSC unconfigures the transceiverEquipment object
concerned.

CAUTION
Service reduction
The service is reduced.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

490

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

process the problem in order that the btsSiteManager object


becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 5.

Check that the alarm on the cavity is valid, by performing


a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "cavity" equipment is "failed", the fault is


confirmed. Go to step 3.

If the state of the "cavity" equipment is "working", the fault is


not confirmed. Go to step 5.

Maintenance at the OMC-R

Lock the transceiverEquipment object concerned in order to


trigger a reset of the CC8 software and a new tuning sequence.

Unlock the transceiverEquipment object.

If the problem has disappeared, go to step 5.


If the problem persists after several attempts, an on-site
intervention is necessary.

The procedure is complete.


--End--

2.12.29 Cavity (source: Cavity parked after tuning fault (power too low))
Fault number 1067

Abis event reporting a hardware fault

Equipment:

Cavity

Source:

(8388613) Cavity parked after tuning fault (power


too low)

BTS model:

S8000 Indoor

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

491

REACTION OF THE SYSTEM


BSC defense The BSC unconfigures the transceiverEquipment object
concerned.
Impact on the service

One TRX becomes unavailable.

CAUTION
Service reduction
The service is reduced.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

492

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the alarm persists, go to step 2.

Otherwise, go to step 5.

Check that the alarm on the cavity equipment is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "cavity" equipment is "failed", the fault is


confirmed. Go to step 3.

If the state of the "cavity" equipment is "working", the fault is


not confirmed. Go to step 5.

Maintenance at the OMC-R

Lock the transceiverEquipment object in order to trigger a new


tuning.

Unlock the transceiverEquipment object.

If the problem has disappeared, go to step 5.


If the problem persists after several attempts, an on-site
intervention is necessary to locate the problem.

The procedure is complete.


--End--

2.12.30 Cavity (source: Cavity parked after tuning fault (tuning detector
problem))
Fault number 1067

Abis event reporting a hardware fault

Equipment:

Cavity

Source:

(8388614) Cavity parked after tuning fault (tuning


detector problems)

BTS model:

S8000 Indoor

REACTION OF THE SYSTEM


BSC defense The BSC unconfigures the transceiverEquipment object
concerned.
Impact on the service

One TRX becomes unavailable.

CAUTION
Service reduction
The service is reduced.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

493

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 5.

Check that the alarm on the cavity equipment is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "cavity" equipment is "failed", the fault is


confirmed. Go to step 3.

If the state of the "cavity" equipment is "working", the fault is


not confirmed. Go to step 5.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

494

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers


Maintenance at the OMC-R

Lock the transceiverEquipment object in order to trigger a new


tuning.

Unlock the transceiverEquipment object.

If the problem has disappeared, go to step 5.


If the problem persists after several attempts, an on-site
intervention is necessary to locate the problem.

The procedure is complete.


--End--

2.12.31 Cavity (source: Internal software problem)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

Cavity

Source:

(8388615) Internal software problem

BTS model:

S8000 Indoor

REACTION OF THE SYSTEM


BSC defense The BSC unconfigures the transceiverEquipment object
concerned.
Impact on the service

One TRX becomes unavailable.

CAUTION
Service reduction
The service is reduced.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

495

GSM BSS Fault Clearing - Advanced Maintenance


Procedures) ).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 5.

Check that the alarm on the cavity equipment is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "cavity" equipment is "failed", the fault is


confirmed. Go to step 3.

If the state of the "cavity" equipment is "working", the fault is


not confirmed. Go to step 5.

Maintenance at the OMC-R

Lock the transceiverEquipment object in order to trigger a new


tuning.

Unlock the transceiverEquipment object.

If the problem has disappeared, go to step 5.


If the problem persists after several attempts, an on-site
intervention is necessary to locate the problem.

The procedure is complete.


--End--

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

496

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

2.12.32 Cavity combiner (source: Power supply)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

Cavity combiner

Source:

(8323073) Power supply

BTS model:

S8000 Indoor

FAULT ANALYSIS
This alarm indicates a power supply problem.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service

None.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

497

object to become "enabled", "disabled-dependency", or


"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 7.

Check that the alarm on the cavity combiner is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "cavity combiner" equipment is "failed", the


fault is confirmed. Go to step 3.

If the state of the "cavity combiner" equipment is "working",


the fault is not confirmed. Go to step 6.

On-site maintenance

If the frequency map has changed and only in this case, replace
the combiner (Field Replaceable Unit). Refer to 411-9001-048
(Nortel GSM BTS S8000/S8003 Troubleshooting).
Go to step 4.

Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 7.


If the alarm persists, go to step 5.

Check the state of the cavity combiner by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "cavity combiner" equipment is still "failed",


call the manufacturer.

If the state of the "cavity combiner" equipment is "working",


go to step 6.

Clear the alarm.

The procedure is complete.


--End--

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

498

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

2.12.33 Cavity combiner (source: Tuning detector fault)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

Cavity combiner

Source:

(8323074) Tuning detector fault

BTS model:

S8000 Indoor

FAULT ANALYSIS
This alarm indicates that it is not possible to modify the standard frequency
of cavities.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service

None.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

499

not clear it. Wait for the state of the btsSiteManager


object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 7.

Check that the alarm on the cavity combiner is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "cavity combiner" equipment is "failed", the


fault is confirmed. Go to step 3.

If the state of the "cavity combiner" equipment is "working",


the fault is not confirmed. Go to step 6.

On-site maintenance

If the frequency map has changed and only in this case, replace
the combiner (Field Replaceable Unit). Refer to 411-9001-048
(Nortel GSM BTS S8000/S8003 Troubleshooting).
Go to step 4.

Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 7.


If the alarm persists, go to step 5.

Check the state of the cavity combiner by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "cavity combiner" equipment is still "failed",


call the manufacturer.

If the state of the "cavity combiner" equipment is "working",


go to step 6.

Clear the alarm.

The procedure is complete.


--End--

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

500

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

2.12.34 Cavity combiner (source: Link NOK)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

Cavity combiner

Source:

(8323076) Link NOK

BTS model:

S8000 Indoor

FAULT ANALYSIS
This alarm indicates that level 3 dialogue has been lost.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service

None

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

501

object to become "enabled", "disabled-dependency", or


"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 7.

Check that the alarm on the cavity combiner is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "cavity combiner" equipment is "failed", the


fault is confirmed. Go to step 3.

If the state of the "cavity combiner" equipment is "working",


the fault is not confirmed. Go to step 6.

On-site maintenance

If the frequency map has changed and only in this case, replace
the combiner (Field Replaceable Unit). Refer to 411-9001-048
(Nortel GSM BTS S8000/S8003 Troubleshooting).
Go to step 4.

Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 7.


If the alarm persists, go to step 5.

Check the state of the cavity combiner by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "cavity combiner" equipment is still "failed",


call the manufacturer.

If the state of the "cavity combiner" equipment is "working",


go to step 6.

Clear the alarm.

The procedure is complete.


--End--

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

502

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

2.12.35 C-DACS climatic system (source: Dirty filter)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

Compact dacs cooler

Source:

(7929857) Dirty filter

BTS model:

S8002

FAULT ANALYSIS
This alarm is detected by the ALCO or RECAL board.
This alarm occurs when the C-DACS filter is clogged.

REACTION OF THE SYSTEM


BSC defense As soon as the (H)(e)PA temperature is over
60C, the (H)(e)PA are powered off. The BSC unconfigures the
transceiverEquipment objects.
Impact on the service There is no impact on the service until the BTS
and (H)(e)PA have overheated.

CAUTION
Service reduction
The service is reduced.

CAUTION
Working instructions
The intervention on the site must be within one week.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

503

GSM BSS Fault Clearing - Advanced Maintenance


Procedures) ).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 7.

Check that the alarm on the C-DACS climatic system is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "compact dacs cooler" equipment is "failed",


the fault is confirmed. Go to step 3.

If the state of the "compact dacs cooler" equipment is


"working", the fault is not confirmed. Go to step 6.

On-site maintenance

Replace the filter (Field Replaceable Unit). Refer to


411-9001-084 (Nortel GSM BTS S8002 Troubleshooting). Go to
step 4.

Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 7.


If the alarm persists, go to step 5.

Check the state of the C-DACS climatic system by performing


a "Display hardware configuration" command on the
btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

504

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Look at the result displayed in the "Session log" window.

If the state of the "compact dacs cooler" equipment is still


"failed", call the manufacturer.

If the state of the "compact dacs cooler" equipment is


"working", go to step 6.

Clear the alarm.

The procedure is complete.


--End--

2.12.36 C-DACS climatic system (source: DACS failed)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

Compact dacs cooler

Source:

(7929858) DACS failed

BTS model:

S8002

FAULT ANALYSIS
This alarm is detected by the ALCO or RECAL board.
This alarm indicates a problem on the C-DACS climatic system.

REACTION OF THE SYSTEM

BSC defense As soon as the (H)(e)PA temperature is over 60C, the


(H)(e)PA is powered off. The BSC unconfigures the transceiverEquipment
objects.
Impact on the service There is no impact on the service until the BTS
and (H)(e)PA overheat.

CAUTION
Service reduction
The service is reduced.

CAUTION
Working instructions
The intervention on the site must be immediate.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

505

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 8.

Check that the alarm on the C-DACS climatic system is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "compact dacs cooler" equipment is "failed",


the fault is confirmed. Go to step 3.

If the state of the "compact dacs cooler" equipment is


"working", the fault is not confirmed. Go to step 7.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

506

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers


On-site maintenance

Check that the L2/CB2 fan circuit breaker (power supply rack) on
the PCU and the climatic circuit breaker (C-AC box) are in the
"I" position.

If this is the case, go to step 5.


If this is not the case, go to step 4.

Reset the circuit breakers.

If the L2/CB2 circuit breaker cannot be reset:


a. Disconnect the DC wires related to the C-DACS (see
411-9001-084 (Nortel GSM BTS S8002 Troubleshooting)
b. Reset the L2/CB2 circuit breaker of the power supply
rack.

In the case of a new break, check the PCU output


cables of the power supply rack. Replace them (Shop
Replaceable Unit). Go to step 5.

Otherwise, the operator can choose whether he


changes the C-DACS (Field Replaceable Unit)
as a whole or he replaces the faulty items (Field
Replaceable Units) of the C-DACS.

CAUTION
ESDS handling precautions
To replace faulty items, the personnel
working on the C-DACS must be
authorized to work according to security
standards.
The personnel must be qualified to work
on the C-DACS: they must be well-trained
on the functioning of the unit.

Go to step 5.

If the climatic circuit breaker of the AC box cannot be reset:


a. Disconnect the AC wires related to the C-DACS (see
411-9001-084 (Nortel GSM BTS S8002 Troubleshooting)
).
b. Reset the climatic circuit breaker of the AC box.

In the case of a new break, replace the climatic circuit


breaker of the AC box (Field Replaceable Unit).
Refer to 411-9001-084 (Nortel GSM BTS S8002
Troubleshooting). Go to step 5.

Otherwise, go to step 5.

Additional checks

Check the alarm state in the "Current Alarm list" window.


Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

507

If the alarm has disappeared, go to step 8.


If the alarm persists, go to step 6.

Check the state of the C-DACS climatic system by performing


a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "compact dacs cooler" equipment is still


"failed", call the manufacturer.

If the state of the "compact dacs cooler" equipment is


"working", go to step 7.

Clear the alarm.

The procedure is complete.


--End--

2.12.37 CMCF board (source: MCF_MCF)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

CMCF or CMCF phase 1 or CMCF phase 2

Source:

(9502729 or 12779529 or 12845065) MCF_MCF

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
This alarm indicates a loss of link between the active board and the
passive board.
REACTION OF THE SYSTEM

BSC defense
None.
Impact on the service

CAUTION
Service interruption
There is no impact on the service unless there is a fault on the
other CMCF board. The service will then be lost.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

508

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 8.

Check that the alarm on the CMCF board is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

509

Look at the result displayed in the "Session log" window.

If the state of the "CMCF" equipment is "failed", the fault is


confirmed. Go to step 3.

If the state of the "CMCF" equipment is "working", the fault is


not confirmed. Go to step 7.

On-site maintenance using the OMC-R

If there are BISTs on the board, note their state by performing a


"Display data configuration" command on the btsSiteManager
object.
In this case, look at the result displayed in the "Session log"
window and send these to the manufacturer with the faulty
board.

Replace the faulty CMCF board (Field Replaceable Unit). Refer


to:

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8000 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for


the S8002 BTS

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8003 BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for


the S8006 BTS

Go to step 5.
Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 8.


If the alarm persists, go to step 6.

Check the state of the CMCF board by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "CMCF" equipment is still "failed", call the


manufacturer.

If the state of the "CMCF" equipment is "working", go to step


7.

Clear the alarm.

The procedure is complete.


--End--

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

510

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

2.12.38 CMCF board (source: Slave downloading error)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

CMCF or CMCF phase 1 or CMCF phase 2

Source:

(9568250 or 12845050 or 12910586) Slave


downloading error

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
This alarm, sent by the active board, indicates an error during the update
of the passive board by the active one.
REACTION OF THE SYSTEM

BSC defense
None.
Impact on the service
The CBCF duplex mode is lost. The CBCF simplex mode continues to
function.

CAUTION
Service interruption
There is no impact on the service unless there is a fault on the
other CMCF board. The service will then be lost.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

511

GSM BSS Fault Clearing - Advanced Maintenance


Procedures)).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 10.

Check that the alarm on the CMCF board is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "CMCF" equipment is "failed", the fault is


confirmed. Go to step 3.

If the state of the "CMCF" equipment is "working", the fault is


not confirmed. Go to step 9.

On-site maintenance

Perform the following steps in the maintenance window of the


operator.

Remove the active board.

CAUTION
Service reduction
The service is reduced.

Wait for the BSC defense actions and its start-up.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

512

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Replace the newly passive CMCF board (Field Replaceable


Unit). Refer to:

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8000 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for


the S8002 BTS

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8003 BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for


the S8006 BTS

Go to step 7.
Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 10.


If the alarm persists, go to step 8.

Check the state of the CMCF board by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "CMCF" equipment is still "failed", call the


manufacturer.

If the state of the "CMCF" equipment is "working", go to step


9.

Clear the alarm.

10

The procedure is complete.


--End--

2.12.39 CMCF board (source: CMCF_ACT_DUPLEX_INHIBITED)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

CMCF phase 1 or CMCF phase 2

Source:

(12779538 or 12845074) CMCF ACT DUPLEX


INHIBITED

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
This alarms is due to secured loop commissioning error on one BTS of
the loop.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

513

This alarms indicates passive CMCF board is not commissioned


accordingly to the mode required (Secured Loop mode is asked while the
secured loop passive CMCF microswitch is not set).
REACTION OF THE SYSTEM

BSC defense
None.
Impact on the service
For the btsSiteManager object.

CAUTION
Service interruption
There is no impact on the service unless there is a fault on the
other CMCF board. The service will then be lost.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

514

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the alarm persists, go to step 2.

Otherwise, go to step 7.

Check that the Secured loop both CMCF microswitch (number


4) are correctly set by performing a "Display data information
/Normal" command on the faulty btsSiteManager.
Look at the result displayed in the "Session log" window.
Check the CMCF switch state in the session log window, "Switch
state" must be in "Secured loop mode" for active and passive
boards. Go to Step 4.

If the Switch state is in "Secured loop mode" for active and


passive boards. Go to Step 4.

If the Switch state is not in Secured loop mode, the CMCF


microswitch number 4 has to be set to ON. Go to Step 3

On-site maintenance

Refer to following technical documents to set passive CMCF


microswitch number 4 to on: "Follow Chapter : replacement of a
CMCF board"

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8000 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for


the S8002 BTS

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8003 BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for


the S8006 BTS

Go to step 4.
Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 7.


If the alarm persists, go to step 5.

Check that the Secured loop both CMCF microswitch (number


4) are correctly set by performing a "Display data information
/Normal" command on the btsSiteManager.
Look at the result displayed in the "Session log" window.

Check the CMCF switch state in the session log window,


"Switch state" must be in "Secured loop mode" for active

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

515

and passive boards. If the state of the "CMCF" equipment is


"working", go to step 7.

If the Switch state is not in Secured loop mode, the CMCF


microswitch number 4 has to be set to ON. Call the
manufacturer.

Clear the alarm.

The procedure is complete.


--End--

2.12.40 CMCF board (source: CMCF_ACT_ICST)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

CMCF phase 1 or CMCF phase 2

Source:

(12779539 or 12845075) CMCF ACT ICST

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
This alarms is due to secured loop commissioning error on one BTS of
the loop.
This alarms indicates passive CMCF board is not commissioned
accordingly to the mode required (Secured Loop mode is asked while the
secured loop passive CMCF microswitch is not set).
REACTION OF THE SYSTEM

BSC defense
None.
Impact on the service
For the btsSiteManager object.

CAUTION
Service interruption
As long as the operationalState of the btsSiteManager object is
"disabled-- failed", the site is lost. No service is provided.

TROUBLESHOOTING
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

516

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 7.

Check that the Secured loop both CMCF microswitch (number


4) are correctly set by performing a "Display data information
/Normal" command on the faulty btsSiteManager.
Look at the result displayed in the "Session log" window.
Check the CMCF switch state in the session log window, "Switch
state" must be in "Secured loop mode" for active and passive
boards. Go to Step 4.

If the Switch state be in "Secured loop mode" for active and


passive boards. Go to Step 4.

If the Switch state is not in Secured loop mode, the CMCF


microswitch number 4 has to be set to ON. Go to Step 3

On-site maintenance

Refer to following technical documents to set passive CMCF


microswitch number 4 to on: Follow Chapter : replacement of a
CMCF board

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

517

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8000 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for


the S8002 BTS

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8003 BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for


the S8006 BTS

Go to step 4.
Additional checks

Perform a Lock / Unlock on faulty btsSiteManager


Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 7.


If the alarm persists, go to step 5.

Check that the Secured loop both CMCF microswitch (number


4) are correctly set by performing a "Display data information
/Normal" command on the btsSiteManager.
Look at the result displayed in the "Session log" window.

Check the CMCF switch state in the session log window,


"Switch state" must be in "Secured loop mode" for active
and passive boards. If the state of the "CMCF" equipment is
"working", go to step 7.

If the Switch state is not in Secured loop mode, the CMCF


microswitch number 4 has to be set to ON. Call the
manufacturer.

Clear the alarm.

The procedure is complete.


--End--

2.12.41 CMCF board (source: Duplex inhibited: feature not supported


on CMCF phase 1)
Fault number 1067

Abis event reporting a hardware fault

Equipment:

CMCF phase 1

Source:

(12779540) Duplex inhibited: feature not supported


on CMCF phase 1

BTS model:

S8000 Outdoor CBCF + S8000 Indoor CBCF

FAULT ANALYSIS

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

518

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

The alarm 1067 with cause 12779540 is sent in two different cases:

Case 1: The CMCF phase 1 board does not support the GPS and the
BTS (master/slave) synchronization features.

The alarm indicates that a CMCF phase 1 board has been plugged
in a BTS configured for synchronization features such as GPS
synchronization or BTS (master/slave) synchronization.

GPS and BTS synchronization features are not allowed in case of


mixed configurations (the active is CMCF phase 2 and passive is
CMCF phase 1) and so the CBCF duplex mode is lost.

As the CMCF phase 1 board does not support synchronization


features, CBCF BTS must only have CMCF phase 2 boards.

The alarm is cleared when the CMCF phase 1 board is plugged


out.

Case 2: The CMCF phase 1 board does not support the Dynamic Abis
feature (which is only compatible with CBCF with CMCF phase 2).

If a passive CMCF phase 1 board is plugged with an active CMCF


phase 2 board, the duplex functionality is inhibited and an alarm
1067 cause 12779540 Duplex inhibited: feature not supported by
CMCF phase 1 is sent on the CMCF phase 1 board.

The fault is cleared when the CMCF phase 1 board is plugged out.
In case a Display data information action is launched at the
OMC-R in this situation, the site Dynamic Abis capability and the
site Dynamic Abis state information are inconsistent.
REACTION OF THE SYSTEM

BSC defense
None.
Impact on the service
The CBCF duplex mode is lost. The CBCF simplex mode continues to
function.

CAUTION
Service interruption
There is no impact on the service unless there is a fault on the
active CMCF board. The service will then be lost.

TROUBLESHOOTING
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

Step

519

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is no operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 7.

Check that the alarm on the CMCF board is valid by performing


a "Display hardware information" command mode Standard on
the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "CMCF" equipment is "failed", the fault is


confirmed. Go to step 3.

If the state of the "CMCF" equipment is "working", the fault is


not confirmed. Go to step 6.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

520

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers


On-site maintenance

Replace the CMCF Phase 1 board with a CMCF Phase 2 board


(Field Replaceable Unit):

refer to Nortel GSM BTS S8000/S8003 Troubleshooting


(411-9001-048) for the BTS S8000

refer to Nortel GSM BTS S8002 Troubleshooting


(411-9001-084) for the BTS S8002

refer to Nortel GSM BTS S8000/S8003 Troubleshooting


(411-9001-048) for the BTS S8003

refer to Nortel GSM BTS S8006 Troubleshooting


(411-9001-085) for the BTS S8006

Go to step 4.
Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 7.


If the alarm persists, go to step 5.

Check the state of the CMCF board by performing a "Display


hardware information" command mode Standard on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "CMCF" equipment is still "failed", call the


manufacturer.

If the state of the "CMCF" equipment is "working", go to step


6.

Clear the alarm.

The procedure is complete.


--End--

2.12.42 Combiner duplexer LNA or combiner H2 LNA (source: LNA


fault)
Fault number 1067

Abis event reporting a hardware fault

Equipment:

combiner duplexer lna or combiner h2 lna (LNA)

Source:

(5570561) LNA fault

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

521

This alarm is detected by the ALCO or RECAL board.


This alarm indicates a hardware problem on the low noise amplifier. The
related reception path (main or diversity) is no longer operational for all
the TRXs using the faulty LNA. However, if the other path is still correct,
these TRXs run in a degraded mode.
REACTION OF THE SYSTEM

BSC defense
If there is no reception path, the BSC unconfigures the transceiver
Equipment objects corresponding to the faulty LNA. One or several
transceiverEquipment objects can be lost.
Impact on the service

CAUTION
Service reduction
The service is reduced.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

522

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

process the problem in order that the btsSiteManager object


becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 14.

Check the state of F-type converters by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "converter F" equipment is "failed", go to


step 4.

If the state of the "converter F" equipment is "working", go to


step 3.

Check that the alarm on the combiner duplexer LNA is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "LNA" equipment is "failed", the fault is


confirmed. Go to step 6.

If the state of the "LNA" equipment is "working", the fault is


not confirmed. Go to step 13.

On-site maintenance using the OMC-R

Look for alarms concerning the F-type converters and process


them.

If the alarm has disappeared, go to step 14.


If the alarm persists, go to step 5.

If the circuit breaker powering the PA is in the "O" position, put it


in the "I" position. Go to step 7.

If the operationalState of the bts object is "disabled" and its


availabilityStatus is "dependency", set the administrativeState of

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

523

the bts object to "locked", and set the administrativeState of the


associated transceiverEquipment objects to "locked".
7

Replace the RF-combiner (Field Replaceable Unit) associated


with the LNA-combiner. Refer to:

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8000 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for


the S8002 BTS

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8003 BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for


the S8006 BTS

Check the cable between the LNA and the connection panel.

If it is correct, go to step 9.
If it is not correct, replace it (Shop Replaceable Unit).
If the alarm has disappeared, go to step 14.
If the alarm persists, go to step 9.

Replace the ALCO or RECAL board (Field Replaceable Units).

For the ALCO board of the S8000 BTS, refer to


411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting)

For the RECAL board of the S8000 BTS, refer to


411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting)

For the RECAL board of the S8002 BTS, refer to


411-9001-084 (Nortel GSM BTS S8002 Troubleshooting)

For the RECAL board of the S8003 BTS, refer to


411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting)

For the RECAL board of the S8006 BTS, refer to


411-9001-085 (Nortel GSM BTS S8006 Troubleshooting)
If the alarm has disappeared, go to step 14.
If the alarm persists, go to step 10.

10

Check the cable between the connection panel and the ALCO
or RECAL board.

If it is correct, go to step 11.


If it is not correct, replace it (Shop Replaceable Unit). Go to
step 11.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

524

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers


Additional checks

11

Check the alarm state in the "Current Alarm list" window.

12

If the alarm has disappeared, go to step 14.


If the alarm persists, go to step 12.

Check the state of the equipment by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "LNA" equipment is still "failed", call the


manufacturer.

If the state of the "LNA" equipment is "working", go to step


13.

13

Clear the alarm.

14

The procedure is complete.


--End--

2.12.43 Combiner duplexer VSWR or combiner H2 VSWR (source:


VSWR level 1)
Fault number 1067

Abis event reporting a hardware fault

Equipment:

combiner duplexer vswr or combiner h2 vswr


(VSWR)

Source:

(5636097) VSWR level 1

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
This alarm indicates that an abnormal VSWR level has been detected at
the combiner output. The radio link is still operating.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service

None.

2.12.44 Combiner duplexer VSWR or combiner H2 VSWR (source:


VSWR level 2)
Fault number 1067
Equipment:

Abis event reporting a hardware fault


combiner duplexer vswr or combiner h2 vswr

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

525

Source:

(5636098) VSWR level 2

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
This alarm indicates that an abnormal VSWR level has been detected at
the combiner output. The radio link is still operating.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service

None.

2.12.45 Combiner duplexer VSWR or combiner H2 VSWR (source:


VSWR level 3)
Fault number 1067

Abis event reporting a hardware fault

Equipment:

combiner duplexer vswr or combiner h2 vswr

Source:

(5636099) VSWR level 3

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
This alarm is detected by the ALCO or RECAL board.
This alarm indicates that the radio link is interrupted in the transmission
direction for all the TRXs using the corresponding antenna. These TRXs
are no longer operational.

REACTION OF THE SYSTEM


BSC defense The BSC unconfigures the transceiverEquipment objects
connected to the RF-combiner that has detected the fault.

CAUTION
Service reduction
The service is reduced.

CAUTION
Working instructions
Intervention on the site must be immediate.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

526

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 13.

Check that the alarm on the combiner D / H2D VSWR is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "VSWR" equipment is "failed", the fault is


confirmed. Go to step 3.

If the state of the "VSWR" equipment is "working", the fault is


not confirmed. Go to step 12.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

527

On-site maintenance using the OMC-R

If the operationalState of the bts object is "disabled" and its


availabilityStatus is "dependency", set the administrativeState of
the bts object to "locked", and set the administrativeState of the
associated transceiverEquipment objects to "locked".

Note the contents of the additional fields in the notifications and


send these, if any, to the manufacturer with the faulty item.

Check the cable between the associated RF-combiner and the


interconnection panel.

If it is correct, go to step 6.
If it is not correct, replace it (Shop Replaceable Unit).
If the alarm has disappeared, go to step 13.
If the alarm persists, go to step 6.

Replace the associated RF-combiner (Field Replaceable Unit).


Refer to:

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8000 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for


the S8002 BTS

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8003 BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for


the S8006 BTS
If the alarm has disappeared, go to step 13.
If the alarm persists, go to step 7.

Replace the ALCO or RECAL board (Field Replaceable Units).

For the ALCO board of the S8000 BTS, refer to


411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting)

For the RECAL board of the S8000 BTS, refer to


411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting)

For the RECAL board of the S8002 BTS, refer to


411-9001-084 (Nortel GSM BTS S8002 Troubleshooting)

For the RECAL board of the S8003 BTS, refer to


411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting)

For the RECAL board of the S8006 BTS, refer to


411-9001-085 (Nortel GSM BTS S8006 Troubleshooting)

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

528

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the alarm has disappeared, go to step 13.


If the alarm persists, go to step 8.
8

Check the cable between the interconnection panel and the


ALCO or RECAL board.

If it is correct, go to step 9.
If it is not correct, replace it (Shop Replaceable Unit).
If the alarm has disappeared, go to step 13.
If the alarm persists, go to step 9.

If necessary, set the administrativeState of the bts and


transceiverEquipment objects to "unlocked". Go to step 10.

Additional checks

10

Check the alarm state in the "Current Alarm list" window.

11

If the alarm has disappeared, go to step 13.


If the alarm persists, go to step 11.

Check the state of the replaced equipment by performing


a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "SWR" equipment is still "failed", call the


manufacturer.

If the state of the "SWR" equipment is "working", go to step


12.

12

Clear the alarm.

13

The procedure is complete.


--End--

2.12.46 Combiner H4D LNA (source: LNA fault)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

combiner h4 lna (LNA)

Source:

(7405569) LNA fault

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm is detected by the ALCO or RECAL board.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

529

This alarm indicates a hardware problem on the low noise amplifier. The
related reception path (main or diversity) is not operational for all the TRXs
using the faulty LNA. However, if the other path is still correct, these TRXs
run in a degraded mode.

REACTION OF THE SYSTEM


BSC defense The BSC unconfigures the transceiverEquipment objects
corresponding to the faulty LNA. One or several transceiverEquipment
objects can be lost.

CAUTION
Service reduction
The service is reduced.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

530

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

object to become "enabled", "disabled-dependency", or


"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 14.

Check the state of F-type converters by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "converter F" equipment is "failed", go to


step 4.

If the state of the "converter F" equipment is "working", go to


step 3.

Check that the alarm on the combiner duplexer LNA is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "LNA" equipment is "failed", the fault is


confirmed. Go to step 6.

If the state of the "LNA" equipment is "working", the fault is


not confirmed. Go to step 13.

On-site maintenance using the OMC-R

Look for alarms concerning the F-type converters and process


them.

If the alarm has disappeared, go to step 14.


If the alarm persists, go to step 5.

If the circuit breaker powering the PA is in the "O" position, put it


in the "I" position. Go to step 7.

If the operationalState of the bts object is "disabled" and its


availabilityStatus is "dependency", set the administrativeState of
the bts object to "locked", and set the administrativeState of the
associated transceiverEquipment objects to "locked".

Replace the RF-combiner (Field Replaceable Unit) associated


with the LNA-combiner. Refer to 411-9001-048 (Nortel GSM BTS
S8000/S8003 Troubleshooting).

Check the cable between the LNA and the connection panel.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

531

If it is correct, go to step 9.
If it is not correct, replace it (Shop Replaceable Unit).
If the alarm has disappeared, go to step 14.
If the alarm persists, go to step 9.

Replace the ALCO or RECAL board (Field Replaceable Units).

For the ALCO board of the S8000 BTS, refer to


411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting).

For the RECAL board of the S8000 BTS, refer to


411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting).
If the alarm has disappeared, go to step 14.
If the alarm persists, go to step 10.

10

Check the cable between the connection panel and the ALCO
or RECAL board.

If it is correct, go to step 11.


If it is not correct, replace it (Shop Replaceable Unit). Go to
step 11.

Additional checks

11

Check the alarm state in the "Current Alarm list" window.

12

If the alarm has disappeared, go to step 14.


If the alarm persists, go to step 12.

Check the state of the equipment by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "LNA" equipment is still "failed", call the


manufacturer.

If the state of the "LNA" equipment is "working", go to step


13.

13

Clear the alarm.

14

The procedure is complete.


--End--

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

532

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

2.12.47 Combiner H4D VSWR (source: VSWR level 1)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

combiner h4 vswr (VSWR)

Source:

(7471105) VSWR level 1

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm indicates that an abnormal VSWR level has been detected at
the combiner output. The radio link is still operating.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service

None.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. process the problem on the btsSiteManager
object.
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 11.

Check that the alarm on the combiner H4D VSWR is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

533

Look at the result displayed in the "Session log" window.

If the state of the "VSWR" equipment is "failed", the fault is


confirmed. Go to step 3.

If the state of the "VSWR" equipment is "working", the fault is


not confirmed. Go to step 10.

On-site maintenance from the OMC-R

If the operationalState of the bts object is "disabled" and its


availabilityStatus is "dependency", set the administrativeState of
the bts object to "locked", and set the administrativeState of the
associated transceiverEquipment objects to "locked".

Note the contents of the additional fields in the notifications and


send these, if any, to the manufacturer with the faulty item.

Check the cabling between the associated RF-combiner and the


antenna.

In the case of three alarms with source: level 1, source: level 2,


and source: level 3, replace the associated RF-combiner (Field
Replaceable Unit). Refer to 411-9001-048 (Nortel GSM BTS
S8000/S8003 Troubleshooting).

If necessary, set the administrativeState of the bts object to


"unlocked". Go to step 8.

Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 11.


If the alarm persists, go to step 9.

Check the state of the replaced equipment by performing


a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "VSWR" equipment is still "failed", call the


manufacturer.

If the state of the "VSWR" equipment is "working", go to step


10.

10

Clear the alarm.

11

The procedure is complete.


--End--

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

534

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

2.12.48 Combiner H4D VSWR (source: VSWR level 2)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

combiner h4 vswr (VSWR)

Source:

(7471106) VSWR level 2

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm indicates that an abnormal VSWR level has been detected at
the combiner output. The radio link is still operating.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service

None.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. process the problem on the btsSiteManager
object.
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 11.

Check that the alarm on the combiner H4D VSWR is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

535

Look at the result displayed in the "Session log" window.

If the state of the "VSWR" equipment is "failed", the fault is


confirmed. Go to step 3.

If the state of the "VSWR" equipment is "working", the fault is


not confirmed. Go to step 10.

On-site maintenance from the OMC-R

If the operationalState of the bts object is "disabled" and its


availabilityStatus is "dependency", set the administrativeState of
the bts object to "locked", and set the administrativeState of the
associated transceiverEquipment objects to "locked".

Note the contents of the additional fields in the notifications and


send these, if any, to the manufacturer with the faulty item.

Check the cabling between the associated RF-combiner and the


antenna.

In the case of three alarms with source: level 1, source: level 2,


and source: level 3, replace the associated RF-combiner (Field
Replaceable Unit). Refer to 411-9001-048 (Nortel GSM BTS
S8000/S8003 Troubleshooting).

If necessary, set the administrativeState of the bts object to


"unlocked". Go to step 8.

Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 11.


If the alarm persists, go to step 9.

Check the state of the replaced equipment by performing


a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "VSWR" equipment is still "failed", call the


manufacturer.

If the state of the "VSWR" equipment is "working", go to step


10.

10

Clear the alarm.

11

The procedure is complete.


--End--

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

536

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

2.12.49 Combiner H4D VSWR (source: VSWR level 3)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

combiner h4 vswr (VSWR)

Source:

(7471107) VSWR level 3

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm is detected by the ALCO or RECAL board.
This alarm indicates that the radio link is interrupted in the transmission
direction for all the TRXs using the corresponding antenna. These TRXs
are no longer operational.

REACTION OF THE SYSTEM


BSC defense The BSC unconfigures the transceiverEquipment objects
connected to the RF-combiner that has detected the fault.

CAUTION
Service reduction
The service is reduced.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

537

process the problem in order that the btsSiteManager object


becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 13.

Check that the alarm on the combiner H4D VSWR is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "VSWR" equipment is "failed", the fault is


confirmed. Go to step 3.

If the state of the "VSWR" equipment is "working", the fault is


not confirmed. Go to step 12.

On-site maintenance using the OMC-R

If the operationalState of the bts object is "disabled" and its


availabilityStatus is "dependency", set the administrativeState of
the bts object to "locked", and set the administrativeState of the
associated transceiverEquipment objects to "locked".

Note the contents of the additional fields in the notifications and


send these, if any, to the manufacturer with the faulty item.

Check the cable between the associated RF-combiner and the


interconnection panel.

If it is correct, go to step 6.
If it is not correct, replace it (Shop Replaceable Unit).
If the alarm has disappeared, go to step 13.
If the alarm persists, go to step 6.

Replace the associated RF-combiner (Field Replaceable


Unit). Refer to 411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting).

If the alarm has disappeared, go to step 13.


If the alarm persists, go to step 7.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

538

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Replace the ALCO or RECAL board (Field Replaceable Units).

For the ALCO board of the S8000 BTS, refer to


411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting).

For the RECAL board of the S8000 BTS, refer to


411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting).
If the alarm has disappeared, go to step 13.
If the alarm persists, go to step 8.

Check the cable between the interconnection panel and the


ALCO or RECAL board.

If it is correct, go to step 9.
If it is not correct, replace it (Shop Replaceable Unit).
If the alarm has disappeared, go to step 13.
If the alarm persists, go to step 9.

If necessary, set the administrativeState of the bts and


transceiverEquipment objects to "unlocked". Go to step 10.

Additional checks

10

Check the alarm state in the "Current Alarm list" window.

11

If the alarm has disappeared, go to step 13.


If the alarm persists, go to step 11.

Check the state of the equipment by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "VSWR" equipment is still "failed", call the


manufacturer.

If the state of the "VSWR" equipment is "working", go to step


12.

12

Clear the alarm.

13

The procedure is complete.


--End--

2.12.50 Compact distribution system (source: Main breaker)


Fault number 1067
Equipment:

Abis event reporting a hardware fault


compact distribution

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

Source:

(7995393) Main breaker

BTS model:

S8002

539

FAULT ANALYSIS
This alarm is detected by the ALCO or RECAL board.
This alarm appears when the cabinet main breaker is disengaged after an
internal short-circuit in the cabinet.
The cabinet then operates on its batteries. The fault number 1067 with the
source "Battery on discharges" on the rectifier equipment is displayed.

REACTION OF THE SYSTEM


BSC defense
None.

CAUTION
Service interruption
If the problem is not corrected, the BTS can be lost.
If the BTS is lost, PCM faults will appear.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed" and process the
problem in order that the btsSiteManager object becomes
"enabled".
If no object is concerned and if a fault number 1054 (loss
of layer 2) has appeared:

If the cabinet is out of order, process the problem on


the cabinet. Go to step 3.

Otherwise, refer to the fault number 1054 (see


411-9001-105 (Nortel GSM BSS Fault Clearing Advanced Maintenance Procedures)).

If a pcmCircuit object is "disabled-failed":

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

540

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the cabinet is out of order, process the problem on


the cabinet. Go to step 3.

Look for a fault number concerning PCMs (see


411-9001-105 (Nortel GSM BSS Fault Clearing Advanced Maintenance Procedures)).

If an lapdLink object is "disabled-failed", the BSC is


concerned. Look for alarms concerning the BSC.

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 8.

Check that the alarm on the compact distribution system is valid,


by performing a "Display hardware configuration" command on
the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "compact distribution" equipment is "failed",


the fault is confirmed. Go to step 4.

If the state of the "compact distribution" equipment is


"working", the fault is not confirmed. Go to step 7.

On-site maintenance

Check the mains power supply on the operator box.

If the mains power supply is correct, it is a PCM fault. Refer


to the fault number 1054 (see 411-9001-105 (Nortel GSM
BSS Fault Clearing - Advanced Maintenance Procedures)).

If not, solve the problem concerning the mains power supply


and go to step 5.

Put the main breaker in the "I" position.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

541

If the mains supply is present and if the alarm persists,


replace the C-AC box (Field Replaceable Unit). Refer to
411-9001-084 (Nortel GSM BTS S8002 Troubleshooting). Go
to step 5.

Otherwise, go to step 5.

Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 8.


If the alarm persists, go to step 6.

Check the state of the compact distribution system by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "compact distribution" equipment is still


"failed", call the manufacturer.

If the state of the "compact distribution" equipment is


"working", go to step 7.

Clear the alarm.

The procedure is complete.


--End--

2.12.51 CPCMI board (source: Major)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

CPCMI

Source:

(9568257) Major fault

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

This problem is associated with a PCM fault. See 411-9001-105 (Nortel


GSM BSS Fault Clearing - Advanced Maintenance Procedures)

2.12.52 CPCMI board (source: Slave downloading error)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

CPCMI

Source:

(9633786) Slave downloading error

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

542

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

This alarm indicates an error during the downloading sequence of the


CPCMI board by the active CMCF board.
REACTION OF THE SYSTEM

BSC defense
The BSC unconfigures the btsSiteManager object to maintain a minimum
service of communication. This unconfiguration is displayed at the OMC-R
and is temporary. If a transceiverEquipment object is lost, the fault number
1061 appears.

If there is only one PCM link in service, the BTS is completely


unconfigured. If other BTSs are dropped with the faulty BTS, they are
also unconfigured.

If there are several PCM links declared in the configuration, only a part
of the BTS is lost. A fault number 1061 concerning the transceiver
object appears.

Impact on the service

If there is a redundant CPCMI board, there is no impact on the service.


If two PCM links are used:

CAUTION
Service reduction
The service is reduced.

If one PCM link is used:

CAUTION
Service interruption
The service is lost.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.

543

If a fault number 1054 (loss of layer 2) has appeared,


refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 7.

Check that the alarm on the CPCMI board is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "CPCMI" equipment is "failed", the fault is


confirmed. Go to step 3.

If the state of the "CPCMI" equipment is "working", the fault is


not confirmed. Go to step 6.

On-site maintenance

Replace the faulty CPCMI board (Field Replaceable Unit). Refer


to:

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

544

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8000 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for


the S8002 BTS

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8003 BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for


the S8006 BTS

Go to step 4.
Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 7.


If the alarm persists, go to step 5.

Check the state of the CPCMI board by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "CPCMI" equipment is still "failed", call the


manufacturer.

If the state of the "CPCMI" equipment is "working", go to step


6.

Clear the alarm.

The procedure is complete.


--End--

2.12.53 CSWM board


(source: Fault on active-passive CSWM link or on passive CSWM)
Fault number 1067

Abis event reporting a hardware fault

Equipment:

CSWM

Source:

(4259849) Fault on active-passive CSWM link or


passive CSWM

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm indicates a hardware or software failing on the passive CSWM
board. There is no longer a connection between the active and passive
CSWM board.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

545

REACTION OF THE SYSTEM


BSC defense
None.

CAUTION
Service interruption
There is no impact on the service unless there is a fault on the
other CSWM board.
The service will then be lost.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

546

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the alarm persists, go to step 2.

Otherwise, go to step 9.

Check that the alarm on the CSWM board is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "CSWM" equipment is "failed", the fault is


confirmed. Go to step 3.

If the state of the "CSWM" equipment is "working", the fault is


not confirmed. Go to step 8.

Location

The board indicated in the notification is the faulty board.

On-site maintenance using the OMC-R

If there are BISTs on the board, note their state by performing a


"Display data configuration" command on the btsSiteManager
object.
Look at the result displayed in the "Session log" window and
send these to the manufacturer with the faulty board.

Replace the faulty CSWM board (Field Replaceable Unit).


Refer to 411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting). Go to step 6.

Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 9.


If the alarm persists, go to step 7.

Check the state of the CSWM board by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "CSWM" equipment is still "failed", call the


manufacturer.

If the state of the "CSWM" equipment is "working", go to step


8.

Clear the alarm.

The procedure is complete.


--End--

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

547

2.12.54 CSWM board (source: Slave downloading error)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

CSWM

Source:

(4325370) Slave downloading error

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm, sent by the detector board, indicates an error during the
update of the passive board by the active board.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service The BCF duplex mode is lost. The BCF simplex
mode continues to function.

CAUTION
Service interruption
There is no impact on the service unless there is a fault on the
other CSWM board.
The service will then be lost.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

548

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 11.

Check that the alarm on the CSWM board is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "CSWM" equipment is "failed", the fault is


confirmed. Go to step 3.

If the state of the "CSWM" equipment is "working", the fault is


not confirmed. Go to step 10.

Fault location

The board indicated in the notification is the faulty board.

On-site maintenance

If the faulty CSWM board is the active one, go to step 5.


Otherwise, go to step 7.

Set the btsSiteManager object to "locked".

Set the btsSiteManager object to "unlocked".

If the alarm has disappeared, go to step 11.


If the alarm persists, go to step 7.

Replace the faulty CSWM board (Field Replaceable Unit).


Refer to 411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting). Go to step 8.

Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 11.


If the alarm persists, go to step 9.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

549

Check the state of the CSWM board by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "CSWM" equipment is still "failed", call the


manufacturer.

If the state of the "CSWM" equipment is "working", go to step


10.

10

Clear the alarm.

11

The procedure is complete.


--End--

2.12.55 DACS climatic system (source: Dirty filter)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

dacsCooler

Source:

(7864321) Dirty filter

BTS model:

S8000 Outdoor + S8006

FAULT ANALYSIS
This alarm is detected by the ALCO or RECAL board.
This alarm occurs when the DACS filter is clogged.
REACTION OF THE SYSTEM

BSC defense
As soon as the (H)(e)PA temperature is over 60C, the (H)(e)PA are
powered off, and the BSC unconfigures the transceiverEquipment objects.
Impact on the service
There is no impact on the service until the BTS and (H)(e)PA overheat.

CAUTION
Service reduction
The service is reduced.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

550

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

CAUTION
Working instructions
Intervention on the site must be within one week.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 7.

Check that the alarm on the DACS climatic system is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

551

Look at the result displayed in the "Session log" window.

If the state of the "dacsCooler" equipment is "failed", the fault


is confirmed. Go to step 3.

If the state of the "dacsCooler" equipment is "working", the


fault is not confirmed. Go to step 6.

On-site maintenance

Replace the filter (Field Replaceable Unit).

For the S8000 BTS, refer to 411-9001-048 (Nortel GSM BTS


S8000/S8003 Troubleshooting)

For the S8006 BTS, refer to 411-9001-085 (Nortel GSM BTS


S8006 Troubleshooting)

Go to step 4.
Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 7.


If the alarm persists, go to step 5.

Check the state of the DACS climatic system by performing


a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "dacsCooler" equipment is still "failed", call


the manufacturer.

If the state of the "dacsCooler" equipment is "working", go to


step 6.

Clear the alarm.

The procedure is complete.


--End--

2.12.56 DACS climatic system (source: DACS failed)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

dacsCooler

Source:

(7864322) DACS failed

BTS model:

S8000 Outdoor + S8006

FAULT ANALYSIS
This alarm is detected by the ALCO or RECAL board.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

552

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

This alarm indicates a problem on the DACS climatic system.


REACTION OF THE SYSTEM

BSC defense
As soon as the (H)(e)PA temperature is over 60C, the (H)(e)PA is
powered off. The BSC unconfigures the transceiverEquipment objects.
Impact on the service
There is no impact on the service until the BTS and (H)(e)PA overheat.

CAUTION
Service reduction
The service is reduced.

CAUTION
Working instructions
Intervention on the site must be within one week.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

553

the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 8.

Check that the alarm on the DACS climatic system is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "dacsCooler" equipment is "failed", the fault


is confirmed. Go to step 3.

If the state of the "dacsCooler" equipment is "working", the


fault is not confirmed. Go to step 7.

On-site maintenance

Check that the fan circuit breakers are in the "I" position.
Breakers are located on the power supply rack (if present), GIPS
(if present) and the AC box (if present).

If they are in the "I" position, go to step 5.


If they are in the "O" position, go to step 4.

Reset the circuit breakers.

If the L2/CB2 circuit breaker can not be reset:


a. Disconnect the DC wires related to the DACS (see
411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting) for the S8000 BTS or 411-9001-085
(Nortel GSM BTS S8006 Troubleshooting) for the S8006
BTS).
b. Reset the L2/CB2 circuit breaker of the power supply
rack.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

554

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If there is a new break, check the PCU output cables


of the power supply rack. Replace them (Shop
Replaceable Unit). Go to step 5.

Otherwise, the operator can choose whether he


changes the DACS (Field Replaceable Unit) as
a whole or he replaces the faulty items (Field
Replaceable Units) of the DACS. In this case:

for the S8000 BTS, refer to 411-9001-048 (Nortel


GSM BTS S8000/S8003 Troubleshooting) to
detect and replace the faulty item.

for the S8006 BTS, refer to 411-9001-085 (Nortel


GSM BTS S8006 Troubleshooting) to detect and
replace the faulty item.

CAUTION
ESDS handling precautions
The personnel replacing faulty DACS
items must be well trained on the
functionalities of the unit, and authorized
to work according to security standards.

Go to step 5.

If the climatic circuit breaker of the AC box can not be reset:


a. Disconnect the AC wires related to the DACS (see
411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting) for the S8000 BTS or 411-9001-085
(Nortel GSM BTS S8006 Troubleshooting) for the S8006
BTS).
b. Reset the climatic circuit breaker of the AC box.

If there is a new break, replace the climatic circuit


breaker of the AC box (Field Replaceable Unit).

For the S8000 BTS, refer to 411-9001-048 (Nortel


GSM BTS S8000/S8003 Troubleshooting)

For the S8006 BTS, refer to 411-9001-085 (Nortel


GSM BTS S8006 Troubleshooting)

Go to step 4.

Otherwise, go to step 5.

Additional checks

Perform the following steps:

Check the DACS thermostat state.


If the thermostat is tripped, re-activate it (refer to step 9).

Check the alarm state in the "Current Alarm list" window.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

555

a. If the alarm has disappeared, go to step 8.


b. If the alarm persists, go to step 6.
6

Check the state of the DACS climatic system by performing


a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "dacsCooler" equipment is still "failed", call


the manufacturer.

If the state of the "dacsCooler" equipment is "working", go to


step 7.

Clear the alarm.

The procedure is complete.

Re-activation of the DACS thermostat.

Intervention time
a. The intervention time is approximately 20 minutes.

Tools required
a. Stepladder
b. Flat screwdriver
c. Allen wrench

Impact of the replacement on service

DANGER
Electric shock
The BTS does not remain supplied with the mains
power supply, so take care while handling the
equipment.

Location
a. The DACS thermostat is located on the following figure.

a Safety instructions

CAUTION
ESDS handling precautions
Wear the antistatic bracelet when performing the
following maintenance procedure.

b Preliminary operations
1. Open the hood and the doors of the cabinet.
2. Put the battery circuit breaker in the "O" position.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

556

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

3. Put the main circuit breaker in the "O" position.


4. Put the "FAN" breakers in the "O" position.
5. Unscrew the four quarter turn fasteners of the DACS
cover and carefully remove it.
c Re-activation of the thermostat
1. Press the red button which is located at the top of the
thermostat.
The thermostat is located between the blowers. It is fixed
on the heater cover (refer to the following figure).
d Additional operations
1. Replace the DACS cover and screw its eight 1/4 turn
fasteners.
2. Put the "FAN" breakers in the "I" position.
3. Put the main circuit breaker in the "I" position.
4. Put the battery circuit breaker in the "I" position.
5. Close the doors and the hood of the cabinet.
10

Clear the alarm.

11

The procedure is complete.


--End--

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)
Figure 1
S8000 Outdoor BTS and S8006 BTS DACS thermostat re-activation

2.12.57 Distribution system (source: Main breaker)


Fault number 1067
Equipment:

Abis event reporting a hardware fault


Distribution system

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

557

558

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Source:

(5767169) Main breaker

BTS model:

S8000 Outdoor + S8002 + S8006

FAULT ANALYSIS
This alarm appears when the cabinet main breaker is disengaged after an
internal short-circuit in the cabinet.
The cabinet is operating on its batteries, if any. The fault number 1060
with the source "Battery on discharges" is displayed, and may be followed
by a source "External battery level 1" if the batteries are discharged (see
the fault number 1060 source "External battery level 1").
REACTION OF THE SYSTEM

BSC defense
None.
Impact on the service

CAUTION
Service interruption
If the problem is not corrected, the BTS can be lost.
If the BTS is lost, PCM faults will appear.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed" and process the
problem in order that the btsSiteManager object becomes
"enabled".
If no object is concerned and if a fault number 1054 (loss
of layer 2) has appeared:

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

559

If the cabinet is out of order, process the problem on


the cabinet. Go to step 3.

Otherwise, refer to the fault number 1054 (see


411-9001-105 (Nortel GSM BSS Fault Clearing Advanced Maintenance Procedures)).

If a pcmCircuit object is "disabled-failed":

If the cabinet is out of order, process the problem on


the cabinet. Go to step 3.

Look for a fault number concerning PCMs (see


411-9001-105 (Nortel GSM BSS Fault Clearing Advanced Maintenance Procedures)).

If an lapdLink object is "disabled-failed", the BSC is


concerned. Look for alarms concerning the BSC.

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 8.

Check that the alarm on the distribution system is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "distribution system" equipment is "failed",


the fault is confirmed. Go to step 4.

If the state of the "distribution system" equipment is


"working", the fault is not confirmed. Go to step 7.

On-site maintenance

Check the mains power supply on the operator box, or on the


"Battery and Interface" module, if it is used.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

560

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the mains power supply is correct, it is a PCM fault. Refer


to the fault number 1054 (see 411-9001-105 (Nortel GSM
BSS Fault Clearing - Advanced Maintenance Procedures)).

If not, solve the problem concerning the mains power supply


and go to step 5.

Put the main breaker in the "I" position.

If the mains supply is present and if the alarm persists,


replace the main breaker (Field Replaceable Unit).
For the S8000 BTS, refer to 411-9001-048 (Nortel GSM
BTS S8000/S8003 Troubleshooting).
For the S8002 BTS, refer to 411-9001-084 (Nortel GSM
BTS S8002 Troubleshooting).
For the S8006 BTS, refer to 411-9001-085 (Nortel GSM
BTS S8006 Troubleshooting).
Go to step 4.

Otherwise, go to step 5.

Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 8.


If the alarm persists, go to step 6.

Check the state of the distribution system by performing


a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "distribution system" equipment is still


"failed", call the manufacturer.

If the state of the "distribution system" equipment is


"working", go to step 7.

Clear the alarm.

The procedure is complete.


--End--

2.12.58 DRX or DRX-ND3 diversity reception chain (source: Software


detection)
Fault number 1067
Equipment:

Abis event reporting a hardware fault


DRX or DRX-ND3 diversity reception chain

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

561

Source:

(6946817) Software detection

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

This alarm is treated by either performing the following procedure or by


performing the procedure associated with the TIL and described in:

411-9001-048 (Nortel GSM BTS S8000/S8003 Troubleshooting) for the


S8000/S8003 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for the S8002


BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for the S8006


BTS

FAULT ANALYSIS
This alarm indicates that the DRX or DRX-ND3 detects a received signal
level difference between the main path and the diversity path.
If the maximum of the two levels is higher than -110dB, and the difference
between the two levels is higher than 20dB, the path that has the lower
level is declared faulty.
As soon as the path which has been declared faulty has a signal level
higher than -110dB, or has a signal slightly lower than the signal level of
the other path, the faulty path is declared operational.
REACTION OF THE SYSTEM

BSC defense
None.
Impact on the service

CAUTION
Service reduction
The service is not lost but it is degraded: the cellular area has
been decreased.

TROUBLESHOOTING

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

562

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 10.

Check that the alarm on the DRX or DRX-ND3 module is valid,


by performing a "Display hardware configuration" command on
the transceiverEquipment object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

563

Look at the result displayed in the "Session log" window.

If the state of the "DRX or DRX-ND3 diversity reception


chain" equipment is "failed", the fault is confirmed. Go to step
3.

If the state of the "DRX or DRX-ND3 diversity reception


chain" equipment is "working", the fault is not confirmed. Go
to step 9.

On-site maintenance

Check the antenna reception route: RF-combiner, Rx-splitter,


DRX or DRX-ND3.

If any cables have been removed, re-insert them. Go to step


4.

Otherwise, go to step 4.

Check that the cables and the connectors are correctly tightened.

If the cables are not correctly tightened, tighten them.


If the alarm persists, go to step 5.
Otherwise, go to step 10.

If the cables are correctly tightened and if the alarm persists,


go to step 5. Otherwise, go to step 10.

Replace the DRX or DRX-ND3 module (Field Replaceable Unit).


Refer to:

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8000 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for


the S8002 BTS

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8003 BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for


the S8006 BTS

Analyze the alarm.

If the alarm persists, go to step 6.


If the alarm has disappeared, go to step 10.

Replace the RF-combiner (Field Replaceable Unit). Refer to:

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8000 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for


the S8002 BTS

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

564

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8003 BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for


the S8006 BTS

Analyze the alarm.

If the alarm persists, replace the Rx-splitter (Field


Replaceable Unit). Refer to:
411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting) for the S8000 BTS
411-9001-084 (Nortel GSM BTS S8002 Troubleshooting)
for the S8002 BTS
411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting) for the S8003 BTS
411-9001-085 (Nortel GSM BTS S8006 Troubleshooting)
for the S8006 BTS
Go to step 7.

If the alarm has disappeared, go to step 10.

Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 10.


If the alarm persists, go to step 8.

Check the state of the DRX or DRX-ND3 module by performing


a "Display hardware configuration" command on the
transceiverEquipment object.
Look at the result displayed in the "Session log" window.

If the state of the "DRX or DRX-ND3 diversity reception


chain" equipment is still "failed", call the manufacturer.

If the state of the "DRX or DRX-ND3 diversity reception


chain" equipment is "working", go to step 9.

Clear the alarm.

10

The procedure is complete.


--End--

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

565

2.12.59 DRX or DRX-ND3 main reception chain (source: Software


detection)
Fault number 1067

Abis event reporting a hardware fault

Equipment:

DRX or DRX-ND3 main reception chain

Source:

(6881281) Software detection

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

This alarm is treated by either performing the following procedure or by


performing the procedure associated with the TIL and described in:

411-9001-048 (Nortel GSM BTS S8000/S8003 Troubleshooting) for the


S8000/S8003 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for the S8002


BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for the S8006


BTS

FAULT ANALYSIS
This alarm indicates that the DRX or DRX-ND3 detects a received signal
level difference between the main path and the diversity path.
If the maximum of the two levels is higher than -110dB, and the difference
between the two levels is higher than 20dB, the path that has the lower
level is declared faulty.
As soon as the path which has been declared faulty has a signal level
higher than -110dB, or has a signal slightly lower than the signal level of
the other path, the faulty path is declared operational.
REACTION OF THE SYSTEM

BSC defense
None.
Impact on the service

CAUTION
Service reduction
The service is not lost but it is degraded: the cellular area is
decreased.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

566

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 10.

Check that the alarm on the DRX or DRX-ND3 module is valid,


by performing a "Display hardware configuration" command on
the transceiverEquipment object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

567

Look at the result displayed in the "Session log" window.

If the state of the "DRX or DRX-ND3 main reception chain"


equipment is "failed", the fault is confirmed. Go to step 3.

If the state of the "DRX or DRX-ND3 main reception chain"


equipment is "working", the fault is not confirmed. Go to step
9.

On-site maintenance

Check the antenna reception route: RF-combiner, Rx-splitter,


DRX or DRX-ND3.

If any cables have been removed, re-insert them. Go to step


4.

Otherwise, go to step 5.

Check that the cables and the connectors are correctly tightened.

If the cables are not correctly tightened, tighten them.


If the alarm persists, go to step 5.
Otherwise, go to step 10.

If the cables are correctly tightened and if the alarm persists,


go to step 5. Otherwise, go to step 10.

Replace the DRX or DRX-ND3 module (Field Replaceable Unit).


Refer to:

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8000 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for


the S8002 BTS

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8003 BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for


the S8006 BTS

Analyze the alarm.

If the alarm persists, go to step 6.


If the alarm has disappeared, go to step 10.

Replace the RF-combiner (Field Replaceable Unit). Refer to:

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8000 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for


the S8002 BTS

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

568

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8003 BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for


the S8006 BTS

Analyze the alarm.

If the alarm persists, replace the Rx-splitter (Field


Replaceable Unit). Refer to:
411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting) for the S8000 BTS
411-9001-084 (Nortel GSM BTS S8002 Troubleshooting)
for the S8002 BTS
411-9001-084 (Nortel GSM BTS S8002 Troubleshooting)
for the S8003 BTS
411-9001-085 (Nortel GSM BTS S8006 Troubleshooting)
for the S8006 BTS
Go to step 7.

If the alarm has disappeared, go to step 10.

Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 10.


If the alarm persists, go to step 8.

Check the state of the DRX or DRX-ND3 module by performing


a "Display hardware configuration" command on the
transceiverEquipment object.
Look at the result displayed in the "Session log" window.

If the state of the "DRX or DRX-ND3 main reception chain"


equipment is still "failed", call the manufacturer.

If the state of the "DRX or DRX-ND3 main reception chain"


equipment is "working", go to step 9.

Clear the alarm.

10

The procedure is complete.


--End--

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

569

2.12.60 DRX or DRX-ND3 modules (source: Abis satellite not supported


DRX (ND3))
Fault number 1067

Abis event reporting a hardware fault

Equipment:

DRX or DRX-ND3

Source:

9437214: Abis satellite not supported DRX

Source:

12976158: Abis satellite not supported DRX ND3

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
This alarm indicates a hardware incompatibility: the "satellite" BTS is
equipped with either DRX or DRX ND3, whereas it must be equipped
with eDRX only, to be able to support the Abis satellite interface (optional
feature).
REACTION OF THE SYSTEM
BSC defense
After the CBCF has sent an "Enable TRX Ack" message with the
availability status set to "Unavailable", the configuration of the TRX is
stopped at BSC level.
Impact on the service
At least one DRX or DRX-ND3 is unavailable.
TROUBLESHOOTING
Replace the DRX or DRX ND3 with eDRX. Refer to:

411-9001-048 (Nortel GSM BTS S8000/S8003 Troubleshooting) for


the S8000 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for the S8002


BTS

411-9001-048 (Nortel GSM BTS S8000/S8003 Troubleshooting) for


the S8003 BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for the S8006


BTS

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

570

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

2.12.61 DRX or DRX-ND3 modules (source: HePA not supported)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

DRX or DRX-ND3

Source:

(9437212) HePA not supported

BTS model:

S8000 Indoor + S8000 Outdoor + S8002 + S8003

FAULT ANALYSIS
This alarm indicates an HePA installation has been attempted on a DRX or
DRX-ND3. Only eDRX supports HePA.
REACTION OF THE SYSTEM
BSC defense
None.
Impact on the service
None.
TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

571

process the problem in order that the btsSiteManager object


becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 10.

Check that the alarm on the DRX or DRX-ND3 is valid, by


performing a "Display hardware configuration" command on the
transceiverEquipment object.
Look at the result displayed in the "Session log" window.

If the state of the "DRX or DRX-ND3" equipment is "failed",


the fault is confirmed. Go to step 3.

If the state of the "DRX or DRX-ND3" equipment is "working",


the fault is not confirmed. Go to step 9.

On-site maintenance using the OMC-R

In the case of an S8000 BTS, perform a "Display" command on


the bts object.
The "standardIndicator" parameter indicates the frequency
band associated with the DRX or DRX-ND3 module: "gsm", "
gsm850", "dcs1800", "pcs1900", "R gsm", "gsmdcs" or "dcsgsm".

If the "standardIndicator" parameter is "gsm 850pcs", perform


a "Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or DRX-ND3 is "gsm850".
If the "transceiverEquipmentClass" parameter is "2", the
DRX or DRX-ND3 is PCS.

If the "standardIndicator" parameter is "pcsgsm850", perform


a "Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or DRX-ND3 is PCS.
If the "transceiverEquipmentClass" parameter is "2", the
DRX or DRX-ND3 is "gsm850".

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

572

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the "standardIndicator" parameter is "gsmdcs", perform a


"Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or DRX-ND3 is GSM.
If the "transceiverEquipmentClass" parameter is "2", the
DRX or DRX-ND3 is DCS.

If the "standardIndicator" parameter is "dcsgsm", perform a


"Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or DRX-ND3 is DCS.
If the "transceiverEquipmentClass" parameter is "2", the
DRX or DRX-ND3 is GSM.

Note the contents of the additional fields in the notifications and


send these, if any, to the manufacturer with the faulty item.

Replace the HePA with a PA. Refer to:

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8000 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for


the S8002 BTS

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8003 BTS

Otherwise, replace the DRX with an eDRX. Refer to:

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8000 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for


the S8002 BTS

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8003 BTS

Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 10.


If the alarm persists, go to step 8.

Check the state of the DRX or DRX-ND3 by performing


a "Display hardware configuration" command on the
transceiverEquipment object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

573

Look at the result displayed in the "Session log" window.

If the state of the "DRX or DRX-ND3" equipment is still


"failed", call the manufacturer.

If the state of the "DRX or DRX-ND3" equipment is "working",


go to step 9.

Clear the alarm.

10

The procedure is complete.


--End--

2.12.62 DRX or DRX-ND3 modules (source: PA configuration exceeded)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

DRX or DRX-ND3

Source:

9437211 or 12582939: PA config. exceeded

BTS model:

S8000 Indoor + S8000 Outdoor + S8002 + S8003

FAULT ANALYSIS
This alarm indicates either:

the maximum supported configuration for the HePA/PA has been


reached; the DRX or DRX-ND3 (s) in excess of the supported
configuration cannot be connected.

an HePA installation has been attempted on the S8000 BTS with BCF.
The S8000 BTS with BCF does not support HePA.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
None.
TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

574

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 10.

Check that the alarm on the DRX or DRX-ND3 is valid, by


performing a "Display hardware configuration" command on the
transceiverEquipment object.
Look at the result displayed in the "Session log" window.

If the state of the "DRX or DRX-ND3" equipment is "failed",


the fault is confirmed. Go to step 3.

If the state of the "DRX or DRX-ND3" equipment is "working",


the fault is not confirmed. Go to step 9.

On-site maintenance using the OMC-R

In the case of an S8000 BTS, perform a "Display" command on


the bts object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

575

The "standardIndicator" parameter indicates the frequency


band associated with the DRX or DRX-ND3 module: "gsm", "
gsm850", "dcs1800", "pcs1900", "R gsm", "gsmdcs" or "dcsgsm".

If the "standardIndicator" parameter is "gsm 850pcs", perform


a "Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or DRX-ND3 is "gsm850".
If the "transceiverEquipmentClass" parameter is "2", the
DRX or DRX-ND3 is PCS.

If the "standardIndicator" parameter is "pcsgsm850", perform


a "Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or DRX-ND3 is PCS.
If the "transceiverEquipmentClass" parameter is "2", the
DRX or DRX-ND3 is "gsm850".

If the "standardIndicator" parameter is "gsmdcs", perform a


"Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or DRX-ND3 is GSM.
If the "transceiverEquipmentClass" parameter is "2", the
DRX or DRX-ND3 is DCS.

If the "standardIndicator" parameter is "dcsgsm", perform a


"Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or DRX-ND3 is DCS.
If the "transceiverEquipmentClass" parameter is "2", the
DRX or DRX-ND3 is GSM.

Note the contents of the additional fields in the notifications and


send these, if any, to the manufacturer with the faulty item.

For the S8000 BTS with BCF, replace the HePA with a PA. Refer
to:

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting)

Otherwise, replace an HePA(s) of the cabinet with PA(s) until the


HePA/PA configuration is supported. The replaced HePA can
be the HePA of a DRX or DRX-ND3 that has been successfully
connected. Refer to:

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

576

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8000 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for


the S8002 BTS

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8003 BTS

Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 10.


If the alarm persists, go to step 8.

Check the state of the DRX or DRX-ND3 by performing


a "Display hardware configuration" command on the
transceiverEquipment object.
Look at the result displayed in the "Session log" window.

If the state of the "DRX or DRX-ND3" equipment is still


"failed", ensure the maximum supported configuration has not
been reached. Otherwise, call the manufacturer.

If the state of the "DRX or DRX-ND3" equipment is "working",


go to step 9.

Clear the alarm.

10

The procedure is complete.


--End--

2.12.63 DRX or eDRX or DRX-ND3 modules (source: BBFILTER ASIC


fault)
Fault number 1067

Abis event reporting a hardware fault

Equipment:

DRX or eDRX or DRX-ND3

Source:

9437190 or 12582918 or 12976134: BBFILTER


ASIC fault

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

This alarm is treated by either performing the following procedure or by


performing the procedure associated with the TIL and described in:

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

577

411-9001-048 (Nortel GSM BTS S8000/S8003 Troubleshooting) for the


S8000/S8003 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for the S8002


BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for the S8006


BTS

FAULT ANALYSIS
This alarm indicates a hardware problem.
REACTION OF THE SYSTEM

BSC defense
The BSC unconfigures the faulty transceiverEquipment object and the
associated transceiver object. It tries to assure a minimum service of
communication by unconfiguring and reconfiguring the transceiver object.
Impact on the service
At least one DRX or DRX-ND3 is lost.

CAUTION
Service reduction
The cell linked to the faulty DRX or DRX-ND3 can be lost.
The service is reduced.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

578

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

GSM BSS Fault Clearing - Advanced Maintenance


Procedures) ).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 12.

Check that the alarm on the DRX or DRX-ND3 module is valid,


by performing a "Display hardware configuration" command on
the transceiverEquipment object.
Look at the result displayed in the "Session log" window.

If the state of the "DRX or DRX-ND3" equipment is "failed",


the fault is confirmed. Go to step 3.

If the state of the "DRX or DRX-ND3" equipment is "working",


the fault is not confirmed. Go to step 11.

On-site maintenance using the OMC-R

In the case of an S8000 BTS, perform a "Display" command on


the bts object.
The "standardIndicator" parameter indicates the frequency
band associated with the DRX or DRX-ND3 module: "gsm", "
gsm850", "dcs1800", "pcs1900", "R gsm", "gsmdcs" or "dcsgsm".

If the "standardIndicator" parameter is "gsm 850pcs", perform


a "Display" command on the transceiverEquipment object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

579

If the "transceiverEquipmentClass" parameter is "1", the


DRX or DRX-ND3 is "gsm850".
If the "transceiverEquipmentClass" parameter is "2", the
DRX or DRX-ND3 is PCS.

If the "standardIndicator" parameter is "pcsgsm850", perform


a "Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or DRX-ND3 is PCS.
If the "transceiverEquipmentClass" parameter is "2", the
DRX or DRX-ND3 is "gsm850".

If the "standardIndicator" parameter is "gsmdcs", perform a


"Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or DRX-ND3 is GSM.
If the "transceiverEquipmentClass" parameter is "2", the
DRX or DRX-ND3 is DCS.

If the "standardIndicator" parameter is "dcsgsm", perform a


"Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or DRX-ND3 is DCS.
If the "transceiverEquipmentClass" parameter is "2", the
DRX or DRX-ND3 is GSM.

Note the contents of the additional fields in the notifications and


send these, if any, to the manufacturer with the faulty item.

Set the administrativeState of the transceiverEquipment object


corresponding to the faulty DRX or DRX-ND3 to "locked".

CAUTION
Service reduction
In most cases, the transceiverEquipment and one
transceiver objects are lost.
The service is reduced.

Disconnect the PWR cable on the front panel of the DRX


(DRXICO side).

Replace the DRX or DRX-ND3 module (Field Replaceable Unit).


Refer to:

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8000 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for


the S8002 BTS

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

580

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8003 BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for


the S8006 BTS

Set the administrativeState of the transceiverEquipment object


corresponding to the faulty DRX or DRX-ND3 to "unlocked". Go
to step 9.

Additional checks

Check the alarm state in the "Current Alarm list" window.

10

If the alarm has disappeared, go to step 12.


If the alarm persists, go to step 10.

Check the state of the DRX or DRX-ND3 module by performing


a "Display hardware configuration" command on the
transceiverEquipment object.
Look at the result displayed in the "Session log" window.

If the state of the "DRX or DRX-ND3" equipment is still


"failed", call the manufacturer.

If the state of the "DRX or DRX-ND3" equipment is "working",


go to step 11.

11

Clear the alarm.

12

The procedure is complete.


--End--

2.12.64 DRX or eDRX or DRX-ND3 modules (source: The TX has not


acknowledged the power consign request)
Fault number 1067

Abis event reporting a hardware fault

Equipment:

DRX or eDRX or DRX-ND3

Source:

9437216 or 12582944 or 12976160: The TX has


not ack the power consign request

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
This alarm indicates that the power, configured at the OMC-R for the DRX
or eDRX or DRX-ND3 concerned, is not compatible with the DRX or eDRX
or DRX-ND3 hardware.
REACTION OF THE SYSTEM

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

581

BSC defense
The BSC configures the transceiver equipment, but the associated
transceiver object is not configured.
Impact on the service
At least one DRX or DRX-ND3 is lost.

CAUTION
Service reduction
The cell linked to the faulty DRX or DRX-ND3 can be lost.
The service is reduced.

CAUTION
Service interruption
Intervention on the site must be immediate: there is a risk of
service loss.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

582

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

a. As long as the operationalState of the btsSiteManager


object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 8.

Maintenance using the OMC-R

Perform a "Display" command on the bts object to check if the


cells are concentric.

If the "concentric cell" parameter is "monozone", go to step 3.


If the "concentric cell" parameter is "concentric" or "dual
band" or "dual coupling", go to step 5.

Check the value of the "bsTxPwrMax" parameter according to


the following information:

For PA: the value of the "bsTxPwrMax" parameter added to


the value to the attenuation of the combiner must be between
31dBm and 44dBm, or 32dBm at the band limit for only GSM
1900.

For HePA: the value of the "bsTxPwrMax" parameter added


to the value to the attenuation of the combiner must be
between 34dBm and 47dBm.

The "bsTxPwrMax" parameter is a parameter of the


powerControl object associated with the bts object.
The "Attenuation" parameter is obtained by a "Display" command
on the btsSiteManager object.
The following table defines the correct values of the
"bsTxPwrMax" parameter, depending on the combiners used in
the BTS. The "Nack" value is not allowed.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

Combiners

TxF/D

H2D

H4D

DLU
attenuation

51
44

Nack

Nack

Nack

43

Pmax

Nack

Nack

42

Pmax

Nack

Nack

41

Pmax-2

Nack

Nack

40

Pmax-2

Pmax

Nack

39

Pmax-4

Pmax

Nack

38

Pmax-4

Pmax-2

Nack

37

Pmax-6

Pmax-2

Nack

36

Pmax-6

Pmax-4

Pmax

35

Pmax-8

Pmax-4

Pmax

34

Pmax-8

Pmax-6

Pmax-2

33

Pmax-10

Pmax-6

Pmax-2

32

Pmax-10

Pmax-8

Pmax-4

31

Pmax-12

Pmax-8

Pmax-4

30

Pmax-12

Pmax-10

Pmax-6

29

Nack

Pmax-10

Pmax-6

28

Nack

Pmax-12

Pmax-8

27

Nack

Pmax-12

Pmax-8

26

Nack

Nack

Pmax-10

25

Nack

Nack

Pmax-10

24

Nack

Nack

Pmax-12

23

Nack

Nack

Pmax-12

22 0

Nack

Nack

Nack

bsTxPwrMax

583

If the value is not correct, change it.


If the value is correct, replace the DRX or DRX-ND3 (Field
Replaceable Unit). Refer to:
411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting) for the S8000 BTS
411-9001-084 (Nortel GSM BTS S8002 Troubleshooting)
for the S8002 BTS

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

584

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8003 BTS
411-9001-085 (Nortel GSM BTS S8006 Troubleshooting)
for the S8006 BTS
Go to step 6.
4

Modify the value of the "bsTxPwrMax" parameter according to


the following information:

For PA: the value of the "bsTxPwrMax" parameter added to


the value to the attenuation of the combiner and reduced of
the value of the "transceiver zone Ref" parameter must be
between 31dBm and 44dBm, or 32dBm at the band limit for
only GSM 1900.

For HePA: the value of the "bsTxPwrMax" parameter added


to the value to the attenuation of the combiner and reduced
of the value of the "transceiver zone Ref" parameter must be
between 34dBm and 47dBm.

The "bsTxPwrMax" parameter is a parameter of the


powerControl object associated with the bts object.
The "transceiver zone Ref" parameter is obtained by performing
a "Display" command on the transceiver object.
The "Attenuation" parameter is obtained by a "Display" command
on the btsSiteManager object. This parameter must not be filled
in for the "dual band" or "dual coupling" values of the "concentric
cell" parameter.
The preceding table defines the correct values of the
"bsTxPwrMax" parameter, depending on the combiners used in
the BTS. The "Nack" value is not allowed. The "transceiver zone
Ref" parameter should also be verified.

If the value is not correct, change it.


If the value is correct, replace the DRX or DRX-ND3 (Field
Replaceable Unit). Refer to:
411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting) for the S8000 BTS
411-9001-084 (Nortel GSM BTS S8002 Troubleshooting)
for the S8002 BTS
411-9001-084 (Nortel GSM BTS S8002 Troubleshooting)
for the S8003 BTS
411-9001-085 (Nortel GSM BTS S8006 Troubleshooting)
for the S8006 BTS
Go to step 5.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

585

Additional checks

Clear the alarm.

Set the bts object to "locked".

Set the bts object to "unlocked".

The procedure is complete.


--End--

2.12.65 DRX or eDRX or DRX-ND3 modules (source: RX fault)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

DRX or eDRX or DRX-ND3

Source:

9437185 or 12582913 or 12976129: RX fault

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

It is possible to treat this alarm either by performing the following


procedure or by performing the procedure associated with the TIL and
described in:

411-9001-048 (Nortel GSM BTS S8000/S8003 Troubleshooting) for


the S8000 BTS

411-9001-048 (Nortel GSM BTS S8000/S8003 Troubleshooting) for


the S8003 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for the S8002


BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for the S8006


BTS

FAULT ANALYSIS
The TRX is no longer operational.
REACTION OF THE SYSTEM

BSC defense
The BSC unconfigures the faulty transceiverEquipment object and the
associated transceiver object. The BSC tries to assure a minimum service
of communication by unconfiguring and reconfiguring the transceiver
object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

586

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Impact on the service


At least one DRX or DRX-ND3 is lost.

CAUTION
Service reduction
The cell linked to the faulty DRX or DRX-ND3 can be lost.
The service is reduced.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 12.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

587

Check that the alarm on the DRX or DRX-ND3 module is valid,


by performing a "Display hardware configuration" command on
the transceiverEquipment object.
Look at the result displayed in the "Session log" window.

If the state of the "DRX or DRX-ND3" equipment is "failed",


the fault is confirmed. Go to step 3.

If the state of the "DRX or DRX-ND3" equipment is "working",


the fault is not confirmed. Go to step 11.

On-site maintenance using the OMC-R

In the case of an S8000 BTS, perform a "Display" command on


the bts object.
The "standardIndicator" parameter indicates the frequency
band associated with the DRX or DRX-ND3 module: "gsm", "
gsm850", "dcs1800", "pcs1900", "R gsm", "gsmdcs" or "dcsgsm".

If the "standardIndicator" parameter is "gsm 850pcs", perform


a "Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or DRX-ND3 is "gsm850".
If the "transceiverEquipmentClass" parameter is "2", the
DRX or DRX-ND3 is PCS.

If the "standardIndicator" parameter is "pcsgsm850", perform


a "Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or DRX-ND3 is PCS.
If the "transceiverEquipmentClass" parameter is "2", the
DRX or DRX-ND3 is "gsm850".

If the "standardIndicator" parameter is "gsmdcs", perform a


"Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or DRX-ND3 is GSM.
If the "transceiverEquipmentClass" parameter is "2", the
DRX or DRX-ND3 is DCS.

If the "standardIndicator" parameter is "dcsgsm", perform a


"Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or DRX-ND3 is DCS.
If the "transceiverEquipmentClass" parameter is "2", the
DRX or DRX-ND3 is GSM.

Note the contents of the additional fields in the notifications and


send these, if any, to the manufacturer with the faulty item.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

588

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Set the administrativeState of the transceiverEquipment object


corresponding to the faulty DRX or DRX-ND3 to "locked".

CAUTION
Service reduction
In most cases, the transceiverEquipment and one
transceiver are lost.
The service is reduced.

Disconnect the PWR cable on the front panel of the DRX


(DRXICO side).

Check the fuse of the DRX INTERCO unit.

If it correct, replace the faulty DRX or DRX-ND3 module


(Field Replaceable Unit). Refer to:
411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting) for the S8000 BTS
411-9001-084 (Nortel GSM BTS S8002 Troubleshooting)
for the S8002 BTS
411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting) for the S8003 BTS
411-9001-085 (Nortel GSM BTS S8006 Troubleshooting)
for the S8006 BTS
Go to step 10.

If it is not correct, replace it (Shop Replaceable Unit). Go to


step 8.

Set the administrativeState of the transceiverEquipment object


corresponding to the faulty DRX or DRX-ND3 to "unlocked". Go
to step 9.

Additional checks

Check the alarm state in the "Current Alarm list" window.

10

If the alarm has disappeared, go to step 12.


If the alarm persists, go to step 10.

Check the state of the DRX or DRX-ND3 module by performing


a "Display hardware configuration" command on the
transceiverEquipment object.
Look at the result displayed in the "Session log" window.

11

If the state of the "DRX or DRX-ND3" equipment is still


"failed", call the manufacturer.

If the state of the "DRX or DRX-ND3" equipment is "working",


go to step 11.

Clear the alarm.


Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

12

589

The procedure is complete.


--End--

2.12.66 DRX or eDRX or DRX-ND3 modules (source: L1M first config


failed)
Fault number 1067

Abis event reporting a hardware fault

Equipment:

DRX or eDRX or DRX-ND3 or eDRX2

Source:

9437488 or 12583216 or 12976432 or 15204656:


L1M first config failed

BTS model:

S8000 Indoor + S8000 Outdoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
This alarm indicates that an anomaly has been detected in an L1M
configuration. One new configuration is allowed after clearing the TRX
configuration
REACTION OF THE SYSTEM

BSC defense
An automatic reconfiguration defense action is triggered by the BSC.
TROUBLESHOOTING
No maintenance action is required.

2.12.67 DRX or eDRX or DRX-ND3 or eDRX2 modules (source: BCCH


first config failed)
Fault number 1067

Abis event reporting a hardware fault

Equipment:

DRX or eDRX or DRX-ND3 or eDRX2

Source:

9437456 or 12583184 or 12976400 or 15204624:


BCCH first config failed

BTS model:

S8000 Indoor + S8000 Outdoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
This alarm indicates that an anomaly has been detected in a BCCH
configuration. One new configuration is allowed after clearing the TRX
configuration.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

590

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

REACTION OF THE SYSTEM

BSC defense
An automatic reconfiguration defense action is triggered by the BSC.
TROUBLESHOOTING
No maintenance action is required.

2.12.68 DRX or eDRX or DRX-ND3 or eDRX2 modules (source: BCCH


second config failed)
Fault number 1067

Abis event reporting a hardware fault

Equipment:

DRX or eDRX or DRX-ND3 or eDRX2

Source:

9437457 or 12583185 or 12976401 or 15204625:


BCCH second config failed

BTS model:

S8000 Indoor + S8000 Outdoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
This alarm indicates that a second anomaly has been detected in a BCCH
configuration. The TRX may no longer be reconfigured, it can now only
be locked or unlocked at any level.
TROUBLESHOOTING
Step

Action

Lock the transceiverEquipment object, then unlock it.

If the alarm persists, go to step 2.

Lock the affected bts object, then unlock it.

If the alarm has disappeared, go to step 3.

If the alarm has disappeared, go to step 3.


If the problem persists, call the manufacturer.

The procedure is complete.


--End--

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

591

2.12.69 DRX or eDRX or DRX-ND3 or eDRX2 modules (source: DRX


link)
Fault number 1067

Abis event reporting a hardware fault

Equipment:

DRX or eDRX or DRX-ND3 or eDRX2

Source:

9437206 or 12582934 or 12976150 or 15204374:


DRX link

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

This alarm is treated by either performing the following procedure or by


performing the procedure associated with the TIL and described in:

411-9001-048 (Nortel GSM BTS S8000/S8003 Troubleshooting) for the


S8000/S8003 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for the S8002


BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for the S8006


BTS

FAULT ANALYSIS
This alarm indicates that the BCF has detected the loss or
non-establishment of the dialogue with the DRX or eDRX or DRX-ND3 or
eDRX2.
REACTION OF THE SYSTEM
BSC defense
The BSC unconfigures the faulty transceiverEquipment object and the
associated transceiver object. It tries to assure a minimum service of
communication by unconfiguring and reconfiguring the transceiver object.
Impact on the service
At least one DRX or eDRX or DRX-ND3 or eDRX2 is lost.

CAUTION
Service reduction
The cell linked to the faulty DRX or eDRX or DRX-ND3 or
eDRX2 can be lost.
The service is reduced.

TROUBLESHOOTING

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

592

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 26.

Check that the alarm on the DRX or eDRX or DRX-ND3 or


eDRX2 module is valid, by performing a "Display hardware
configuration" command on the transceiverEquipment object.
Look at the result displayed in the "Session log" window.

If the state of the DRX or eDRX or DRX-ND3 or eDRX2


equipment is "failed", the fault is confirmed. Go to step 3.

If the state of the DRX or eDRX or DRX-ND3 or eDRX2


equipment is "working", the fault is not confirmed. Go to step
25.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

593

On-site maintenance using the OMC-R

In the case of an S8000 BTS, perform a "Display" command on


the bts object.
The "standardIndicator" parameter indicates the frequency
band associated with the DRX or eDRX or DRX-ND3 or eDRX2
module: "gsm", " gsm850", "dcs1800", "pcs1900", "R gsm",
"gsmdcs" or "dcsgsm".

If the "standardIndicator" parameter is "gsm 850pcs", perform


a "Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or eDRX or DRX-ND3 or eDRX2 is "gsm850".
If the "transceiverEquipmentClass" parameter is "2", the
DRX or eDRX or DRX-ND3 or eDRX2 is PCS.

If the "standardIndicator" parameter is "pcsgsm850", perform


a "Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or eDRX or DRX-ND3 or eDRX2 is PCS.
If the "transceiverEquipmentClass" parameter is "2", the
DRX or eDRX or DRX-ND3 or eDRX2 is "gsm850".

If the "standardIndicator" parameter is "gsmdcs", perform a


"Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or eDRX or DRX-ND3 or eDRX2 is GSM.
If the "transceiverEquipmentClass" parameter is "2", the
DRX or eDRX or DRX-ND3 or eDRX2 is DCS.

If the "standardIndicator" parameter is "dcsgsm", perform a


"Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or eDRX or DRX-ND3 or eDRX2 is DCS.
If the "transceiverEquipmentClass" parameter is "2", the
DRX or eDRX or DRX-ND3 or eDRX2 is GSM.

Note the contents of the additional fields in the notifications and


send these, if any, to the manufacturer with the faulty item.

Set the administrativeState of the transceiverEquipment object


corresponding to the faulty DRX or eDRX or DRX-ND3 or eDRX2
to "locked".

CAUTION
Service reduction
In most cases, the transceiverEquipment and one
transceiver objects are lost.
The service is reduced.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

594

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Check the cable between the DRX or eDRX or DRX-ND3 or


eDRX2 and the DRXICO.

If it is correct, go to step 7.
If it is not correct, replace it (Shop Replaceable Unit).
If the alarm has disappeared, go to step 26.
If the alarm persists, go to step 7.

Replace the faulty DRX or eDRX or DRX-ND3 or eDRX2 module


(Field Replaceable Unit). Refer to:

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8000 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for


the S8002 BTS

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8003 BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for


the S8006 BTS

Set the administrativeState of the transceiverEquipment object


corresponding to the faulty DRX or eDRX or DRX-ND3 or eDRX2
to "unlocked".

If the alarm has disappeared, go to step 26.


If the alarm persists, go to step 9.

For a BTS with BCF, go to step 10. For a BTS with CBCF, go
to step 20.

10

Check the state of the GTW board by performing a "Display data


configuration" command on the btsSiteManager.

If it is correct, go to step 11.


If it is not correct, perform a switchover of the GTW boards.
If the alarm has disappeared, go to step 11.
If the alarm persists, go to step 12.

11

Replace the GTW board (Field Replaceable Unit). Refer to


411-9001-048 (Nortel GSM BTS S8000/S8003 Troubleshooting).

If the alarm has disappeared, go to step 26.


if the alarm persists, go to step 12.

12

If there is one redundant DSC board, go to step 13. Otherwise,


go to step 17.

13

Look for the DSC connected to the faulty DRX or DRX-ND3.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

14

Perform a "Display hardware configuration" command on the


btsSiteManager object to check the number of available DSC
boards.

15

Perform a "Display data configuration" command on the


btsSiteManager to check which DSC board is faulty.

16

Reset the faulty DSC board.

17

595

If the problem persists, go to step 17.


Otherwise, go to step 20.

Replace the DSC board (Field Replaceable Unit). Refer to


411-9001-048 (Nortel GSM BTS S8000/S8003 Troubleshooting).

CAUTION
Service interruption
If there is not any redundant DSC board, the service
is lost.

18

If the alarm has disappeared, go to step 26.


if the alarm persists, go to step 18.

Perform a switchover of the CSWM boards.

If the alarm persists, go to step 19.


If the alarm has disappeared, go to step 26.

19

Replace the faulty CSWM board (Field Replaceable Unit).


Refer to 411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting). Go to step 23.

20

Check the cable between the CBCF and the DRX or DRX-ND3.

If it is correct, go to step 21.


If it is not correct, replace it (Shop Replaceable Unit).
If the alarm has disappeared, go to step 26.
If the alarm persists, go to step 21.

21

Perform a switchover of the CMCF boards.

22

If the alarm persists, go to step 22.


If the alarm has disappeared, go to step 26.

Replace the CMCF board (Field Replaceable Unit). Refer to:

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8000 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for


the S8002 BTS

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

596

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8003 BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for


the S8006 BTS

Go to step 23.
Additional checks

23

Check the alarm state in the "Current Alarm list" window.

24

If the alarm has disappeared, go to step 26.


If the alarm persists, go to step 24.

Check the state of the DRX or eDRX or DRX-ND3 or eDRX2


module by performing a "Display hardware configuration"
command on the transceiverEquipment object.
Look at the result displayed in the "Session log" window.

If the state of the DRX or eDRX or DRX-ND3 or eDRX2


equipment is still "failed", call the manufacturer.

If the state of the DRX or eDRX or DRX-ND3 or eDRX2


equipment is "working", go to step 25.

25

Clear the alarm.

26

The procedure is complete.


--End--

2.12.70 DRX or eDRX or DRX-ND3 or eDRX2 modules (source: DRX


reset by BSC)
Fault number 1067

Abis event reporting a hardware fault

Equipment:

DRX or eDRX or DRX-ND3 or eDRX2

Source:

(9437219 or 12582947 or 12976163 or 15204387:


DRX link NOK after reset requested by BSC

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
This message indicates a reset of the DRX or DRX-ND3 by the BSC.
No maintenance action is required.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

597

2.12.71 DRX or eDRX or DRX-ND3 or eDRX2 modules (source: L1M


second config failed)
Fault number 1067

Abis event reporting a hardware fault

Equipment:

DRX or eDRX or DRX-ND3 or eDRX2

Source:

9437489 or 12583217 or 12976433 or 15204657:


L1M second config failed

BTS model:

S8000 Indoor + S8000 Outdoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
This alarm indicates that a second anomaly has been detected in an L1M
configuration. The TRX may no longer be reconfigured, it can now only
be locked or unlocked at any level.
TROUBLESHOOTING
Step

Action

Lock the transceiverEquipment object, then unlock it.

If the alarm has disappeared, go to step 3.


If the alarm persists, go to step 2.

Lock the affected bts object, then unlock it.

If the alarm has disappeared, go to step 3.


If the problem persists, call the manufacturer.

The procedure is complete.


--End--

2.12.72 DRX or eDRX or DRX-ND3 or eDRX2 modules (source: Major


fault on TX)
Fault number 1067

Abis event reporting a hardware fault

Equipment:

DRX or eDRX or DRX-ND3 or eDRX2

Source:

9437194 or 12582922 or 12976138 or 15204362:


Major fault on TX

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

This alarm is treated by either performing the following procedure or by


performing the procedure associated with the TIL and described in:

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

598

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

411-9001-048 (Nortel GSM BTS S8000/S8003 Troubleshooting) for the


S8000/S8003 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for the S8002


BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for the S8006


BTS

FAULT ANALYSIS
This alarm indicates a problem on the DRX or eDRX or DRX-ND3.
For eDRX2, this is a PSU alarm or a PPL out of lock.
REACTION OF THE SYSTEM

BSC defense
The BSC unconfigures the faulty transceiverEquipment object and the
associated transceiver object. It tries to assure a minimum service of
communication by unconfiguring and reconfiguring the transceiver object.
Impact on the service
At least one DRX or eDRX or DRX-ND3 or eDRX2 is lost.

CAUTION
Service reduction
The cell linked to the faulty DRX or eDRX or DRX-ND3 or
eDRX2 can be lost.
The service is reduced.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

599

If a fault number 1054 (loss of layer 2) has appeared,


refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 14.

Check that the alarm on the DRX or eDRX or DRX-ND3 or


eDRX2 module is valid, by performing a "Display hardware
configuration" command on the transceiverEquipment object.
Look at the result displayed in the "Session log" window.

If the state of the DRX or eDRX or DRX-ND3 or eDRX2


equipment is "failed", the fault is confirmed. Go to step 3.

If the state of the DRX or eDRX or DRX-ND3 or eDRX2


equipment is "working", the fault is not confirmed. Go to step
13.

On-site maintenance using the OMC-R

In the case of an S8000 BTS, perform a "Display" command on


the bts object.
The "standardIndicator" parameter indicates the frequency
band associated with the DRX or eDRX or DRX-ND3 or eDRX2
module: "gsm", " gsm850", "dcs1800", "pcs1900", "R gsm",
"gsmdcs" or "dcsgsm".

If the "standardIndicator" parameter is "gsm 850pcs", perform


a "Display" command on the transceiverEquipment object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

600

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the "transceiverEquipmentClass" parameter is "1", the


DRX or eDRX or DRX-ND3 or eDRX2 is "gsm850".
If the "transceiverEquipmentClass" parameter is "2", the
DRX or eDRX or DRX-ND3 or eDRX2 is PCS.

If the "standardIndicator" parameter is "pcsgsm850", perform


a "Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or eDRX or DRX-ND3 or eDRX2 is PCS.
If the "transceiverEquipmentClass" parameter is "2", the
DRX or eDRX or DRX-ND3 or eDRX2 is "gsm850".

If the "standardIndicator" parameter is "gsmdcs", perform a


"Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or eDRX or DRX-ND3 or eDRX2 is GSM.
If the "transceiverEquipmentClass" parameter is "2", the
DRX or eDRX or DRX-ND3 or eDRX2 is DCS.

If the "standardIndicator" parameter is "dcsgsm", perform a


"Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or eDRX or DRX-ND3 or eDRX2 is DCS.
If the "transceiverEquipmentClass" parameter is "2", the
DRX or eDRX or DRX-ND3 or eDRX2 is GSM.

Note the contents of the additional fields in the notifications and


send these, if any, to the manufacturer with the faulty item.

Set the administrativeState of the transceiverEquipment object


corresponding to the faulty DRX or eDRX or DRX-ND3 or eDRX2
to "locked".

CAUTION
Service reduction
In most cases, the transceiverEquipment and one
transceiver objects are lost.
The service is reduced.

Disconnect the PWR cable on the front panel of the DRX


(DRXICO side).

Check the fuse of the DRX INTERCO unit.

If it is correct, replace the faulty DRX or eDRX or DRX-ND3


or eDRX2 module (Field Replaceable Unit). Refer to:

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

601

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8000 BTS
411-9001-084 (Nortel GSM BTS S8002 Troubleshooting)
for the S8002 BTS
411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting) for the S8003 BTS
411-9001-085 (Nortel GSM BTS S8006 Troubleshooting)
for the S8006 BTS
Go to step 9.

Set the administrativeState of the transceiverEquipment object


corresponding to the faulty DRX or eDRX or DRX-ND3 or eDRX2
to "unlocked".

If it is not correct, replace it (Shop Replaceable Unit). Go to


step 9.

If the alarm has disappeared, go to step 14.


If the alarm persists, go to step 9.

Replace the (H)(e)PA module (Field Replaceable Unit). Refer to:

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8000 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for


the S8002 BTS

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8003 BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for


the S8006 BTS
If the alarm has disappeared, go to step 14.
If the alarm persists, go to step 10.

10

Check the cable between the (H)(e)PA and the DRX or eDRX
or DRX-ND3 or eDRX2.

If it is correct, go to step 11.


If it is not correct, replace it (Shop Replaceable Unit). Go to
step 11.

Additional checks

11

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 14.


If the alarm persists, go to step 12.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

602

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

12

Check the state of the DRX or eDRX or DRX-ND3 or eDRX2


module by performing a "Display hardware configuration"
command on the transceiverEquipment object.
Look at the result displayed in the "Session log" window.

If the state of the DRX or eDRX or DRX-ND3 or eDRX2


equipment is still "failed", call the manufacturer.

If the state of the DRX or eDRX or DRX-ND3 or eDRX2


equipment is "working", go to step 13.

13

Clear the alarm.

14

The procedure is complete.


--End--

2.12.73 DRX or eDRX or DRX-ND3 or eDRX2 modules (source: Nack


answer)
Fault number 1067

Abis event reporting a hardware fault

Equipment:

DRX or eDRX or DRX-ND3 or eDRX2

Source:

9437218 or 12582946 or 12976162 or 15204386:


DRX reset by BCF after message non ack.

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
This message indicates a software anomaly between the BCF and the
DRX or DRX-ND3 or eDRX2.
Call the next level of support.

2.12.74 DRX or eDRX or DRX-ND3 or eDRX2 modules (source: PA DRX


control loop fault)
Fault number 1067

Abis event reporting a hardware fault

Equipment:

DRX or eDRX or DRX-ND3 or eDRX2

Source:

9437217 or 12582945 or 12976161 or 15204385:


PA DRX control loop fault

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

603

ATTENTION
This alarm is treated by either performing the following procedure or by
performing the procedure associated with the TIL and described in:

411-9001-048 (Nortel GSM BTS S8000/S8003 Troubleshooting) for the


S8000/S8003 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for the S8002 BTS
411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for the S8006 BTS

FAULT ANALYSIS
This alarm indicates that the (H)(e)PA emission power - (e,ND3)DRX/(H)(e
)PA control loop configuration has not succeeded.
REACTION OF THE SYSTEM
BSC defense
The BSC unconfigures the faulty transceiverEquipment object and the
associated transceiver object. It tries to assure a minimum service of
communication by unconfiguring and reconfiguring the transceiver object.
Impact on the service
At least one DRX or eDRX or DRX-ND3 or eDRX2 is lost.

CAUTION
Service reduction
The cell linked to the faulty DRX or eDRX or DRX-ND3 or
eDRX2 can be lost.
The service is reduced.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

604

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

GSM BSS Fault Clearing - Advanced Maintenance


Procedures) ).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 15.

Check that the alarm on the DRX or DRX-ND3 module is valid,


by performing a "Display hardware configuration" command on
the transceiverEquipment object.
Look at the result displayed in the "Session log" window.

If the state of the DRX or eDRX or DRX-ND3 or eDRX2


equipment is "failed", the fault is confirmed. Go to step 3.

If the state of the DRX or eDRX or DRX-ND3 or eDRX2


equipment is "working", the fault is not confirmed. Go to step
14.

On-site maintenance using the OMC-R

In the case of an S8000 BTS, perform a "Display" command on


the bts object.
The "standardIndicator" parameter indicates the frequency
band associated with the DRX or eDRX or DRX-ND3 or eDRX2
module: "gsm", " gsm850", "dcs1800", "pcs1900", "R gsm",
"gsmdcs" or "dcsgsm".

If the "standardIndicator" parameter is "gsm 850pcs", perform


a "Display" command on the transceiverEquipment object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

605

If the "transceiverEquipmentClass" parameter is "1", the


DRX or eDRX or DRX-ND3 or eDRX2 is "gsm850".
If the "transceiverEquipmentClass" parameter is "2", the
DRX or eDRX or DRX-ND3 or eDRX2 is PCS.

If the "standardIndicator" parameter is "pcsgsm850", perform


a "Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or eDRX or DRX-ND3 or eDRX2 is PCS.
If the "transceiverEquipmentClass" parameter is "2", the
DRX or eDRX or DRX-ND3 or eDRX2 is "gsm850".

If the "standardIndicator" parameter is "gsmdcs", perform a


"Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or eDRX or DRX-ND3 or eDRX2is GSM.
If the "transceiverEquipmentClass" parameter is "2", the
DRX or eDRX or DRX-ND3 or eDRX2 is DCS.

If the "standardIndicator" parameter is "dcsgsm", perform a


"Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or eDRX or DRX-ND3 or eDRX2 is DCS.
If the "transceiverEquipmentClass" parameter is "2", the
DRX or eDRX or DRX-ND3 or eDRX2 is GSM.

Note the contents of the additional fields in the notifications and


send these, if any, to the manufacturer with the faulty item.

Set the administrativeState of the transceiverEquipment object


corresponding to the faulty DRX or eDRX or DRX-ND3 or eDRX2
to "locked". Go to step 6.

CAUTION
Service reduction
In most cases, the transceiverEquipment and one
transceiver objects are lost.
The service is reduced.

Check the cable between the BCF and the DRX or eDRX or
DRX-ND3 or eDRX2.

If it is correct, disconnect the PWR cable on the front panel of


the DRX (DRXICO side). Go to step 7.

If it is not correct, replace it (Shop Replaceable Unit).


Analyze the alarm.
If the alarm persists, go to step 7.
If the alarm has disappeared, go to step 15.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

606

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Replace the faulty DRX or eDRX or DRX-ND3 or eDRX2 module


(Field Replaceable Unit). Refer to:

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8000 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for


the S8002 BTS

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8003 BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for


the S8006 BTS

Set the administrativeState of the transceiverEquipment object


corresponding to the faulty DRX or eDRX or DRX-ND3 or eDRX2
to "unlocked".
Analyze the alarm.

If the alarm persists, go to step 9.


If the alarm has disappeared, go to step 15.

Replace the (H)(e)PA module (Field Replaceable Unit). Refer to:

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8000 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for


the S8002 BTS

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8003 BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for


the S8006 BTS

Analyze the alarm.

10

If the alarm has disappeared, go to step 15.

Check the RF cable between the DRX or eDRX or DRX-ND3 or


eDRX2 and the (H)(e)PA.

11

If the alarm persists, go to step 10.

If it is disconnected, reconnect it.


If it is not correct, replace it (Shop Replaceable Unit). Go to
step 11.

Perform a lock/unlock of the impacted DRX after replacing or


reconnecting the RF cable, in order to recover the service. Go
to step 12.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

607

Additional checks

12

Check the alarm state in the "Current Alarm list" window.

13

If the alarm has disappeared, go to step 15.


If the alarm persists, go to step 13.

Check the state of the DRX or eDRX or DRX-ND3 or eDRX2


module by performing a "Display hardware configuration"
command on the transceiverEquipment object.
Look at the result displayed in the "Session log" window.

If the state of the DRX or eDRX or DRX-ND3 or eDRX2


equipment is still "failed", call the manufacturer.

If the state of the DRX or eDRX or DRX-ND3 or eDRX2


equipment is "working", go to step 14.

14

Clear the alarm.

15

The procedure is complete.


--End--

2.12.75 DRX or eDRX or DRX-ND3 or eDRX2 modules (source:


Post-mortem dump zone 3)
Fault number 1067

Abis event reporting a hardware fault

Equipment:

DRX or eDRX or DRX-ND3 or eDRX2

Source:

9437427 or 12583155 or 12976371 or 15204595: Post-mortem


dump zone 3

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003 + S8006

FAULT ANALYSIS
This source indicates a post-mortem dump zone 3.

2.12.76 DRX or eDRX or DRX-ND3 or eDRX2 modules (source: SACCH


first config failed)
Fault number 1067

Abis event reporting a hardware fault

Equipment:

DRX or eDRX or DRX-ND3 or eDRX2

Source:

9437472 or 12583200 or 12976416 or 15204640:


SACCH first config failed

BTS model:

S8000 Indoor + S8000 Outdoor + S8002 + S8003


+ S8006

FAULT ANALYSIS

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

608

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

This alarm indicates that an anomaly has been detected in an SACCH


configuration. One new configuration is allowed after clearing the TRX
configuration
REACTION OF THE SYSTEM

BSC defense
An automatic reconfiguration defense action is triggered by the BSC.
TROUBLESHOOTING
No maintenance action is required.

2.12.77 DRX or eDRX or DRX-ND3 or eDRX2 modules (source: SACCH


second config failed)
Fault number 1067

Abis event reporting a hardware fault

Equipment:

DRX or eDRX or DRX-ND3 or eDRX2

Source:

9437473 or 12583201 or 12976417 or 15204641:


SACCH second config failed

BTS model:

S8000 Indoor + S8000 Outdoor + S8002 + S8003 +


S8006

FAULT ANALYSIS
This alarm indicates that a second anomaly has been detected in an
SACCH configuration. The TRX may no longer be reconfigured, it can now
only be locked or unlocked at any level.
TROUBLESHOOTING
Step

Action

Lock the transceiverEquipment object, then unlock it.

If the alarm has disappeared, go to step 3.


If the alarm persists, go to step 2.

Lock the affected bts object, then unlock it.

If the alarm has disappeared, go to step 3.


If the problem persists, call the manufacturer.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

609

The procedure is complete.


--End--

2.12.78 DRX or eDRX or DRX-ND3 or eDRX2 modules (source: Self


test failed)
Fault number 1067

Abis event reporting a hardware fault

Equipment:

DRX or eDRX or DRX-ND3 or eDRX2

Source:

9437193 or 12582921 or 12976137 or 15204361:


Self test failed

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

This alarm is treated by either performing the following procedure or by


performing the procedure associated with the TIL and described in:

411-9001-048 (Nortel GSM BTS S8000/S8003 Troubleshooting) for the


S8000/S8003 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for the S8002


BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for the S8006


BTS

FAULT ANALYSIS
This alarm indicates a problem in the hardware self-test of the DRX or
eDRX or DRX-ND3, or eDRX2.
REACTION OF THE SYSTEM

BSC defense
The BSC unconfigures the faulty transceiverEquipment object and the
associated transceiver object. It tries to assure a minimum service of
communication by unconfiguring and reconfiguring the transceiver object.
Impact on the service
At least one DRX or eDRX or DRX-ND3 or eDRX2 is lost.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

610

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

CAUTION
Service reduction
The cell linked to the faulty DRX or eDRX or DRX-ND3 or
eDRX2 can be lost.
The service is reduced.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 14.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

611

Check that the alarm on the DRX or eDRX or DRX-ND3 or


eDRX2 module is valid, by performing a "Display hardware
configuration" command on the transceiverEquipment object.
Look at the result displayed in the "Session log" window.

If the state of the DRX or eDRX or DRX-ND3 or eDRX2


equipment is "failed", the fault is confirmed. Go to step 3.

If the state of the DRX or eDRX or DRX-ND3 or eDRX2


equipment is "working", the fault is not confirmed. Go to step
13.

On-site maintenance using the OMC-R

In the case of an S8000 BTS, perform a "Display" command on


the bts object.
The "standardIndicator" parameter indicates the frequency
band associated with the DRX or eDRX or DRX-ND3 or eDRX2
module: "gsm", " gsm850", "dcs1800", "pcs1900", "R gsm",
"gsmdcs" or "dcsgsm".

If the "standardIndicator" parameter is "gsm 850pcs", perform


a "Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or eDRX or DRX-ND3 or eDRX2 is "gsm850".
If the "transceiverEquipmentClass" parameter is "2", the
DRX or eDRX or DRX-ND3 or eDRX2 is PCS.

If the "standardIndicator" parameter is "pcsgsm850", perform


a "Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or eDRX or DRX-ND3 or eDRX2 is PCS.
If the "transceiverEquipmentClass" parameter is "2", the
DRX or eDRX or DRX-ND3 or eDRX2 is "gsm850".

If the "standardIndicator" parameter is "gsmdcs", perform a


"Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or eDRX or DRX-ND3 or eDRX2 is GSM.
If the "transceiverEquipmentClass" parameter is "2", the
DRX or eDRX or DRX-ND3 or eDRX2 is DCS.

If the "standardIndicator" parameter is "dcsgsm", perform a


"Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or eDRX or DRX-ND3 or eDRX2 is DCS.
If the "transceiverEquipmentClass" parameter is "2", the
DRX or eDRX or DRX-ND3 or eDRX2 is GSM.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

612

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Note the contents of the additional fields in the notifications and


send these, if any, to the manufacturer with the faulty item.

Set the administrativeState of the transceiverEquipment object


corresponding to the faultyDRX or eDRX or DRX-ND3 or eDRX2
to "locked".

CAUTION
Service reduction
In most cases, the transceiverEquipment and one
transceiver object are lost.
The service is reduced.

Disconnect the PWR cable on the front panel of the DRX


(DRXICO side).

Replace the DRX or eDRX or DRX-ND3 or eDRX2 module (Field


Replaceable Unit). Refer to:

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8000 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for


the S8002 BTS

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8003 BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for


the S8006 BTS

Set the transceiverEquipment object corresponding to the faulty


DRX or eDRX or DRX-ND3 or eDRX2 to "unlocked".

If the alarm has disappeared, go to step 14.


If the alarm persists, go to step 9.

Replace the (H)(e)PA module (Field Replaceable Unit). Refer to:

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8000 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for


the S8002 BTS

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8003 BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for


the S8006 BTS
If the alarm has disappeared, go to step 14.
If the alarm persists, go to step 10.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

10

613

Check the cable between the (H)(e)PA and the DRX or eDRX
or DRX-ND3 or eDRX2.

If it is correct, go to step 11.


If it is not correct, replace it (Shop Replaceable Unit). Go to
step 11.

Additional checks

11

Check the alarm state in the "Current Alarm list" window.

12

If the alarm has disappeared, go to step 14.


If the alarm persists, go to step 12.

Check the state of the DRX or eDRX or DRX-ND3 or eDRX2


module by performing a "Display hardware configuration"
command on the transceiverEquipment object.
Look at the result displayed in the "Session log" window.

If the state of the DRX or eDRX or DRX-ND3 or eDRX2


equipment is still "failed", call the manufacturer.

If the state of the DRX or eDRX or DRX-ND3 or


eDRX2equipment is "working", go to step 13.

13

Clear the alarm.

14

The procedure is complete.


--End--

2.12.79 DRX or eDRX or DRX-ND3 or eDRX2 modules (source: TRX not


anymore configured)
Fault number 1067

Abis event reporting a hardware fault

Equipment:

DRX or eDRX or DRX-ND3 or eDRX2

Source:

9502719 or 12648447 or 13041663 or 15269887:


TRX not anymore configured

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
This message indicates an abnormal state change of a DRX or eDRX or
DRX-ND3 or eDRX2, caused by a software problem.
REACTION OF THE SYSTEM

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

614

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

BSC defense
The BSC unconfigures the faulty transceiverEquipment object and the
associated transceiver object. It tries to assure a minimum service of
communication by unconfiguring and reconfiguring the transceiver object.
Impact on the service

CAUTION
Service reduction
The service is not lost but it is degraded: the cellular area is
decreased.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

615

object to become "enabled", "disabled-dependency", or


"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 7.

Check that the alarm on the DRX or eDRX or DRX-ND3 or


eDRX2module is valid by performing a "Display hardware
configuration" command on the transceiverEquipment object.
Look at the result displayed in the "Session log" window.

If the state of the DRX or eDRX or DRX-ND3 or


eDRX2equipment is "failed", the fault is confirmed. Go to step
3.

If the state of the DRX or eDRX or DRX-ND3 or eDRX2


equipment is "working", the fault is not confirmed. Go to step
6.

Perform the following actions:

Set the transceiverEquipment object to "locked".


Set the transceiverEquipment object to "unlocked".

Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 7.


If the alarm persists, go to step 5.

Check the state of the DRX or eDRX or DRX-ND3 or eDRX2


module by performing a "Display hardware configuration"
command on the transceiverEquipment object.
Look at the result displayed in the "Session log" window.

If the state of the DRX or eDRX or DRX-ND3 or eDRX2


equipment is still "failed", call the manufacturer.

If the state of the DRX or eDRX or DRX-ND3 or


eDRX2equipment is "working", go to step 6.

Clear the alarm.

The procedure is complete.


--End--

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

616

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

2.12.80 DSC boards (source: Major fault)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

DSC

Source:

(4456449) Major fault

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm indicates a hardware or software failing on the DSC board.
There is no longer a connection between the active CSWM board and the
concerned DSC board.

REACTION OF THE SYSTEM

In the case of monolapd and redundancy of the DSC board, there is no


BSC defense action.

In the case of monolapd and non-redundancy of the DSC board, the


BSC unconfigures all the objects and sends a fault number 1054.

In the case of multilapd and redundancy of the DSC board, there is no


BSC defense action.

In the case of multilapd and non-redundancy of the DSC board, the


BSC unconfigures some transceiverEquipment objects.

In the case of monolapd and redundancy of the DSC board, there is


no impact on the service.

In the case of monolapd and non-redundancy of the DSC board:

CAUTION
Service interruption
The service is lost.

In the case of multilapd and redundancy of the DSC board, there is


no impact on the service.

In the case of multilapd and non-redundancy of the DSC board, the


BSC unconfigures some transceiverEquipment objects.

CAUTION
Service interruption
The service is reduced or lost.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

617

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 8.

Check that the alarm on the DSC board is valid, by performing


a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "DSC" equipment is "failed", the fault is


confirmed. Go to step 3.

If the state of the "DSC" equipment is "working", the fault is


not confirmed. Go to step 7.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

618

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers


Location

The equipment number specified in the alarm identifies the faulty


DSC board.

On-site maintenance

Replace the faulty DSC board (Field Replaceable Unit). Refer to


411-9001-048 (Nortel GSM BTS S8000/S8003 Troubleshooting).

Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 8.


If the alarm persists, go to step 6.

Check the state of the DSC board by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "DSC" equipment is still "failed", call the


manufacturer.

If the state of the "DSC" equipment is "working", go to step 7.

Clear the alarm.

The procedure is complete.


--End--

2.12.81 DSC boards (source: Channel_HSCX)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

DSC

Source:

(4456453) Channel_HSCX

BTS model:

S8000 Outdoor + S8000 Indoor

REACTION OF THE SYSTEM


This alarm indicates problems concerning self-tests of the DSC board.
This problem cannot be detected while the board is functioning. The
self-tests occur when the board is reset or when the board starts up.

In the case of monolapd and redundancy of the DSC board, there is no


BSC defense action.

In the case of monolapd and non-redundancy of the DSC board, the


BSC unconfigures all the objects and sends a fault number 1054.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

619

In the case of multilapd and redundancy of the DSC board, there is no


BSC defense action.

In the case of multilapd and non-redundancy of the DSC board, the


BSC unconfigures some transceiverEquipment objects.

In the case of monolapd and redundancy of the DSC board, there is


no impact on the service.

In the case of monolapd and non-redundancy of the DSC board:

CAUTION
Service interruption
The service is lost.

In the case of multilapd and redundancy of the DSC board, there is


no impact on the service.

In the case of multilapd and non-redundancy of the DSC board, the


BSC unconfigures some transceiverEquipment objects.

CAUTION
Service interruption
The service is reduced or lost.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

620

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 7.

Check that the alarm on the DSC board is valid, by performing


a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "DSC" equipment is "failed", the fault is


confirmed. Go to step 3.

If the state of the "DSC" equipment is "working", the fault is


not confirmed. Go to step 6.

On-site maintenance

Replace the faulty board (Field Replaceable Unit). Refer to


411-9001-048 (Nortel GSM BTS S8000/S8003 Troubleshooting).

Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 7.


If the alarm persists, go to step 5.

Check the state of the DSC board by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "DSC" equipment is still "failed", call the


manufacturer.

If the state of the "DSC" equipment is "working", go to step 6.

Clear the alarm.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

621

The procedure is complete.


--End--

2.12.82 External alarm (source: Alarm)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

external alarm

Source:

(7274497) Alarm

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

A supervised external alarm has been detected.. The maintenance action


depends on how the user deals with the alarm. Sixteen external alarms
can be used for each cabinet.

2.12.83 Fan of the base cabinet (source: Cabinet fan fault)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

cabinet fan

Source:

(6225921) Cabinet fan fault

BTS model:

S8000 Indoor + S8003

FAULT ANALYSIS
This alarm is detected by the ALCO (S8000) or RECAL (S8000 and
S8003) board.
For the S8000 Indoor BTS, this alarm indicates that a base cabinet fan
is faulty.
For the S8003 BTS, this alarm indicates that an abnormally high
temperature level has been reached in the cabinet.
There is an increase in the internal temperature of the BTS base cabinet
until the (H)(e)PAs are powered off at 60C.
REACTION OF THE SYSTEM
BSC defense
If the (H)(e)PAs are powered off, the BSC unconfigures the
transceiverEquipment objects.
Impact on the service

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

622

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

CAUTION
Service reduction
The service is reduced.

CAUTION
Working instructions
Intervention on the site must be immediate.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed" and process the
problem in order that the btsSiteManager object becomes
"enabled".
If no object is concerned and if a fault number 1054 (loss
of layer 2) has appeared:

If the cabinet is out of order, process the problem on


the cabinet. Go to step 3.

Otherwise, refer to the fault number 1054 (see


411-9001-105 (Nortel GSM BSS Fault Clearing Advanced Maintenance Procedures)).

If a pcmCircuit object is "disabled-failed":

If the cabinet is out of order, process the problem on


the cabinet. Go to step 3.

Look for a fault number concerning PCMs (see


411-9001-105 (Nortel GSM BSS Fault Clearing Advanced Maintenance Procedures)).

If an lapdLink object is "disabled-failed", the BSC is


concerned. Look for alarms concerning the BSC.

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

623

process the problem in order that the btsSiteManager object


becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 9.

Check that the alarm on the fan is valid, by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "cabinet fan" equipment is "failed", the fault


is confirmed. Go to step 3 (S8000 Indoor BTS) or step 6
(S8003 BTS).

If the state of the "cabinet fan" equipment is "working", the


fault is not confirmed. Go to step 8.

On-site maintenance for the S8000 Indoor BTS

Check the mains power supply on the operator box.

If the mains power supply is correct, it is a PCM fault. Refer


to the fault number 1054 (see 411-9001-105 (Nortel GSM
BSS Fault Clearing - Advanced Maintenance Procedures)).

If not, solve the problem concerning the mains power supply


and go to step 6.

Check the state of the fuse.

If it is correct, go to step 5.
If it is not correct, replace it (Shop Replaceable Unit). Go to
step 8.

Replace the faulty fan (Field Replaceable Unit). Refer to


411-9001-048 (Nortel GSM BTS S8000/S8003 Troubleshooting).
Go to step 8.

On-site maintenance for the S8003 BTS

Check the date of the last air filter replacement. If the filter has
not been replaced within the past six months, replace it. Refer to

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

624

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

411-9001-048 (Nortel GSM BTS S8000/S8003 Troubleshooting).


Go to step 7.
7

Check the state of the fans (Refer to Nortel GSM BTS


S8000/S8003 Troubleshooting (411-9001-048)).

If it is correct, go to step 8.
If it is not correct, replace the faulty fan(s) (Field Replaceable
Unit). Refer to 411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting). Go to step 8.

Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 11.


If the alarm persists, go to step 9.

Check the state of the fan by performing a "Display hardware


configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "cabinet fan" equipment is still "failed", call


the manufacturer.

If the state of the "cabinet fan" equipment is "working", go to


step 10.

10

Clear the alarm.

11

The procedure is complete.


--End--

2.12.84 F-type converters (source: Volt)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

converter F

Source:

(5308417) Volt

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
This alarm is detected by the ALCO or RECAL board.
In this alarm, the equipment number indicates which of the two power
supplies is concerned by the alarm.
REACTION OF THE SYSTEM

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

625

BSC defense

If the second F-type converter is optional, the BTS detects


alarms on the LNA and the VSWR: the BSC unconfigures the
transceiverEquipment and transceiver objects connected to the LNA
and VSWR.

If the second F-type converter is present and if another fault occurs on


the other, the BSC unconfigures the bts, transceiverEquipment and
transceiver objects.

Impact on the service

CAUTION
Service interruption
The service is either reduced or lost.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed" and process the
problem in order that the btsSiteManager object becomes
"enabled".
If no object is concerned and if a fault number 1054 (loss
of layer 2) has appeared:

If the cabinet is out of order, process the problem on


the cabinet. Go to step 3.

Otherwise, refer to the fault number 1054 (see


411-9001-105 (Nortel GSM BSS Fault Clearing Advanced Maintenance Procedures)).

If a pcmCircuit object is "disabled-failed":

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

626

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the cabinet is out of order, process the problem on


the cabinet. Go to step 3.

Look for a fault number concerning PCMs (see


411-9001-105 (Nortel GSM BSS Fault Clearing Advanced Maintenance Procedures)).

If an lapdLink object is "disabled-failed", the BSC is


concerned. Look for alarms concerning the BSC.

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 14.

Check that the alarm on the F-type converter module is valid, by


performing a "Display hardware configuration" command on the
transceiverEquipment object.
Look at the result displayed in the "Session log" window.

If the state of the "converter F" equipment is "failed", the fault


is confirmed. Go to step 4.

If the state of the "converter F" equipment is "working", the


fault is not confirmed. Go to step 13.

On-site maintenance

Check the mains power supply on the operator box.

If the mains power supply is correct, it is a PCM fault. Refer


to the fault number 1054 (see 411-9001-105 (Nortel GSM
BSS Fault Clearing - Advanced Maintenance Procedures)).

If not, solve the problem concerning the mains power supply


and go to step 11.

Check if there are alarms on all combiner VSWRs and on all


combiner LNAs.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

If there are no alarms, go to step 5.


If there are alarms, go to step 10.

Check if, at the same time, the (H)(e)PAs are still powered.

627

If they are not, go to step 6.


If they are, go to step 7.

Check the state of the PA breaker (on the PCU for the rectifier
shelf; on the DCU for the GIPS). If necessary, put it in the "I"
position.
Wait for the end of BSC defense actions. Go to step 11.

Check that the switch on the front panel of the F-type converter
is in the "I" position and that the green led is lit.

If they are, go to step 8.


If they are not, replace the F-type converter (Field
Replaceable Unit). Refer to:
411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting) for the S8000 BTS
411-9001-084 (Nortel GSM BTS S8002 Troubleshooting)
for the S8002 BTS
411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting) for the S8003 BTS
411-9001-085 (Nortel GSM BTS S8006 Troubleshooting)
for the S8006 BTS
Put the switch of the new F-type converter in the "I" position.
Go to step 11.

Put the switch of the F-type converter in the "O" position and
check the fuse in the (H)(e)PA INTERCO unit.

If the fuse is faulty, replace it (Shop Replaceable Unit). Go


to step 10.

If the fuse is correct, go to step 9.

Check the cabling.

10

If it is correct, go to step 10.


If it is not correct, replace the cable (Shop Replaceable Unit).
Go to step 11.

Replace the F-type converter (Field Replaceable Unit). Refer to:

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

628

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8000 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for


the S8002 BTS

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8003 BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for


the S8006 BTS

Put the switch of the new F-type converter in the "I" position. Go
to step 11.
Additional checks

11

Check the alarm state in the "Current Alarm list" window.

12

If the alarm has disappeared, go to step 14.


If the alarm persists, go to step 12.

Check the state of the DRX or DRX-ND3 module by performing


a "Display hardware configuration" command on the
transceiverEquipment object.
Look at the result displayed in the "Session log" window.

If the state of the "converter F" equipment is still "failed", call


the manufacturer.

If the state of the "converter F" equipment is "working", go to


step 13.

13

Clear the alarm.

14

The procedure is complete.


--End--

2.12.85 GTW boards (source: Major fault on GTW)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

GTW

Source:

(4587521) Major fault on GTW

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm indicates a hardware or software failing on the GTW board.
There is no longer a connection between the active CSWM board and the
concerned GTW board.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

629

REACTION OF THE SYSTEM


BSC defense
None.

CAUTION
Service interruption
If there is a redundant board, all the DRX or DRX-ND3s of the
site are not lost.
However, if there is an alarm on each GTW board, all the DRX
or DRX-ND3 of the site are lost.

CAUTION
Working instructions
Intervention on the site must be immediate.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

630

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

object to become "enabled", "disabled-dependency", or


"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 12.

Check that the alarm on the GTW board is valid, by performing


a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "GTW" equipment is "failed", the fault is


confirmed. Go to step 3.

If the state of the "GTW" equipment is "working", the fault is


not confirmed. Go to step 11.

Location

The equipment number specified in the alarm identifies the faulty


GTW board.

On-site maintenance

Check the alarms on each DRX or DRX-ND3 of the BTS.

If there is an "DRX or DRX-ND3 link" notification on each


DRX or DRX-ND3, the problem concerns the BCF.
Check that there is an active GTW board.
If there is, reset it.
If there is not, reset one of the two boards.
Ensure that one board becomes active.

If there is an alarm on only one DRX or DRX-ND3, go to step


5.

If there are no alarms on the DRX or DRX-ND3s, go to step


6.

Replace the DRX or DRX-ND3 (Field Replaceable Unit). Refer to


411-9001-048 (Nortel GSM BTS S8000/S8003 Troubleshooting).

If the alarm has disappeared, go to step 12.


If the alarm persists, go to step 7.

Replace the GTW board (Field Replaceable Unit). Refer to


411-9001-048 (Nortel GSM BTS S8000/S8003 Troubleshooting).

If the alarm has disappeared, go to step 12.


If the alarm persists, go to step 7.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

631

Perform a switchover of the CSWM boards.

If the alarm persists, call the manufacturer.


If the alarm has disappeared, the problem concerns the
previous active CSWM board. Go to step 8.

Replace the previous CSWM active board (Field Replaceable


Unit). Refer to 411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting). Go to step 9.

Additional checks

Check the alarm state in the "Current Alarm list" window.

10

If the alarm has disappeared, go to step 12.


If the alarm persists, go to step 10.

Check the state of the GTW board by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "GTW" equipment is still "failed", call the


manufacturer.

If the state of the "GTW" equipment is "working", go to step


11.

11

Clear the alarm.

12

The procedure is complete.


--End--

2.12.86 Internal batteries (source: Battery disconnected)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

internal battery system

Source:

(5439489) Battery disconnected

BTS model:

S8000 Outdoor + S8002

FAULT ANALYSIS
This alarm is detected by the ALCO or RECAL board.
This alarm is triggered by an internal battery problem or by a connection
problem between the PCU and the batteries.
REACTION OF THE SYSTEM
BSC defense

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

632

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

In principle, there is no defense action.


But if there is a power supply cut, the BSC unconfigures the
btsSiteManager object: all the object states change (the btsSiteManager,
bts and transceiverEquipment objects become "disabled-dependency", and
the pcmCircuit of the ABIS link becomes "disabled-failed").
Impact on the service

CAUTION
Service reduction
If the BSC unconfigures the BTS, the service is reduced.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed" and process the
problem in order that the btsSiteManager object becomes
"enabled".
If no object is concerned and if a fault number 1054 (loss
of layer 2) has appeared:

If the cabinet is out of order, process the problem on


the cabinet. Go to step 3.

Otherwise, refer to the fault number 1054 (see


411-9001-105 (Nortel GSM BSS Fault Clearing Advanced Maintenance Procedures) ).

If a pcmCircuit object is "disabled-failed":

If the cabinet is out of order, process the problem on


the cabinet. Go to step 3.

Look for a fault number concerning PCMs (see


411-9001-105 (Nortel GSM BSS Fault Clearing Advanced Maintenance Procedures) ).

If an lapdLink object is "disabled-failed", the BSC is


concerned. Look for alarms concerning the BSC.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

633

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 9.

Check that the alarm on the internal batteries is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "internal battery system" equipment is


"failed", the fault is confirmed. Go to step 4.

If the state of the "internal battery system" equipment is


"working", the fault is not confirmed. Go to step 8.

On-site maintenance

Check the mains power supply on the operator box.

If the mains power supply is correct, it is a PCM fault. Refer


to the fault number 1054 (see 411-9001-105 (Nortel GSM
BSS Fault Clearing - Advanced Maintenance Procedures) ).

If not, solve the problem concerning the mains power supply


and go to step 6.

Check the state of the circuit breaker of the internal batteries.

If the circuit breakers of the batteries are not in the "I"


position, put them in the "I" position.
If there is a new break, go to step 5.
Otherwise, go to step 7.

If the circuit breakers of the batteries are in the "I" position,


go to step 4.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

634

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Check the internal batteries (see 411-9001-048 (Nortel GSM


BTS S8000/S8003 Troubleshooting) for the S8000 BTS or
411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for the
S8002 BTS).

If the test is failed, replace the internal batteries (Field


Replaceable Unit). Refer to:
411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting) for the S8000 BTS
411-9001-084 (Nortel GSM BTS S8002 Troubleshooting)
for the S8002 BTS
Go to step 6.

If the test is correct, disconnect the cables of the internal


batteries. Go to step 6.

Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 9.


If the alarm persists, go to step 7.

Check the state of the internal batteries by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "internal battery system" equipment is still


"failed", call the manufacturer.

If the state of the "internal battery system" equipment is


"working", go to step 8.

Clear the alarm.

The procedure is complete.


--End--

2.12.87 IP synchro (source: Unable to lock on IP synchronization)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

IP synchro

Source:

(15859968) Unable to lock on IP synchronization

BTS model:

S8000 Indoor + S8000 Outdoor

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

635

FAULT ANALYSIS
The IPM-USER generates an "Unable to lock" event in case the
IPM-USER synchronization module cannot reach a frequency, locked
within an appropriate delay.
The begin-of fault alarm indicates that the counter "unlocked_state_counte
r" reaches a confirmation threshold.
The end-of-fault alarm indicates that the counter "unlocked_state_counter"
is reset.
The causes for this alarm are:

The network impairment rate is too high for the clock recovery
algorithm to lock. This is the most probable cause.

The IPM-USER local oscillator has experienced a large frequency


skew with age. It is no more able to lock to the BSC reference clock
within its nominal tuning range.

The IPM-USER local oscillator is not stable enough, probably due to


thermal variations.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
None.

TROUBLESHOOTING
Procedure 3
Preliminary checks

Step

Action

Check that the alarm on the IPM-USER is valid by performing a


"Display hardware information" command on the IPM object.

ATTENTION
The "Display hardware information" command is not available if a
BTS inventory is already running on the btsSiteManager object.

Look at the result displayed in the "Session log" window.


If the state of the "IPM" equipment is failed, the fault is
confirmed.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

636

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the state of the "IPM" equipment is "working", the fault is not


confirmed. Go to step 3.
On-site maintenance using the OMC-R

Check the alarm state in the "Current Alarm list" window, and
make sure the alarm has disappeared. The alarm disappears
when the counter "unlock_state_counter" is reset.

Clear the alarm, if still present.

The procedure is complete.


--End--

2.12.88 IP synchro (source: Not enough synchronization packets have


been received)
Fault number 1067 Abis event reporting a transient default
Equipment:

IP synchro

Source:

(15859969) Not enough synchronization packets have been received

BTS model:

S8000 Indoor + S8000 Outdoor

FAULT ANALYSIS
The IPM-USER generates a "CRPN drop rate" alarm if it detects an
unacceptable drop rate in the CRPn (Nortel Clock Recovery Protocol)
flow. The network drop rate is too high for the clock recovery algorithm to
operate with the required precision.
The begin-of fault alarm indicates that the counter "CRPN_High_drop_rate
reaches the confirmation threshold.
The end-of fault alarm indicates that the counter "CRPN_High_drop_rate
is reset.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
None.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

637

TROUBLESHOOTING
Procedure 4
Preliminary checks

Step

Action

Check that the alarm on the IPM-USER is valid by performing a


"Display hardware information" command on the IPM object.

ATTENTION
The "Display hardware information" command is not available if a
BTS inventory is already running on the btsSiteManager object.

Look at the result displayed in the "Session log" window.


If the state of the "IPM" equipment is failed, the fault is
confirmed.
If the state of the "IPM" equipment is "working", the fault is not
confirmed. Go to step 3.
On-site maintenance using the OMC-R

Check the alarm state in the "Current Alarm list" window, and
make sure the alarm has disappeared. The alarm disappears
when the counter "unlock_state_counter" is reset.

Clear the alarm, if still present.

The procedure is complete.


--End--

2.12.89 IPM-USER commissioning (source: Only one IBOS


commissioned at IPM)
Fault number 1067

Abis event reporting a hardware fault

Equipment:

IPM-USER commissioning

Source:

(15663140) Only one IBOS commissioned at IPM

BTS model:

S8000 Indoor + S8000 Outdoor

FAULT ANALYSIS
The IPM-USER generates this alarm if only one IBOS is commissioned.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
None.
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

638

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

TROUBLESHOOTING
Procedure 5
Preliminary checks

Step

Action

Check that the alarm on the IPM-USER is valid by performing a


"Display hardware information" command on the IPM object.

ATTENTION
The "Display hardware information" command is not available if a
BTS inventory is already running on the btsSiteManager object.

Look at the result displayed in the "Session log" window.

If the state of the "IPM" equipment is "failed", the fault is


confirmed.

If the state of the "IPM" equipment is "working", the fault is


not confirmed. Go to step 54.

On-site maintenance using the OMC-R

Contact the TAS to recommission the IPM-USER.

Check the alarm state in the "Current Alarm list" window, and
make sure the alarm has disappeared.

Clear the alarm, if still present.

The procedure is complete.


--End--

2.12.90 IPM-USER commissioning (source: DNS resolution has failed


for at least one IBOS)
Fault number 1067

Abis event reporting a hardware fault

Equipment:

IPM-USER commissioning

Source:

(15663141) DNS resolution has failed for at least one IBOS

BTS model:

S8000 Indoor + S8000 Outdoor

FAULT ANALYSIS
The IPM-USER generates this alarm if the DNS resolution has failed for at
least one IBOS.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

639

None.

TROUBLESHOOTING
Procedure 6
Preliminary checks

Step

Action

Check that the alarm on the IPM-USER is valid by performing a


"Display hardware information" command on the IPM object.

ATTENTION
The "Display hardware information" command is not available if a
BTS inventory is already running on the btsSiteManager object.

Look at the result displayed in the "Session log" window.

If the state of the "IPM" equipment is "failed", the fault is


confirmed.

If the state of the "IPM" equipment is "working", the fault is


not confirmed. Go to step 4.

On-site maintenance using the OMC-R

Contact the TAS to recommission the IPM-USER.

Check the alarm state in the "Current Alarm list" window, and
make sure the alarm has disappeared.

Clear the alarm, if still present.

The procedure is complete.


--End--

2.12.91 IPM-USER core (source: IPM BIST failed)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

IPM-USER core

Source:

(15728672) IPM BIST failed

BTS model:

S8000 Indoor + S8000 Outdoor

FAULT ANALYSIS
This alarm indicates a BIST failed for the IPM-USER.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

640

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

None.

TROUBLESHOOTING
Procedure 7
Preliminary checks

Step

Action

Check that the alarm on the IPM-USER is valid by performing a


"Display hardware information" command on the IPM object.

ATTENTION
The "Display hardware information" command is not available if a
BTS inventory is already running on the btsSiteManager object.

Look at the result displayed in the "Session log" window.

If the state of the "IPM" equipment is "failed", the fault is


confirmed.

If the state of the "IPM" equipment is "working", the fault is


not confirmed. Go to step 4.

On-site maintenance using the OMC-R

Replace the IPM-USER.


See Nortel GSM BTS S8000/S8003 Troubleshooting
(411-9001-048).

Check the alarm state in the "Current Alarm list" window, and
make sure the alarm has disappeared.

Clear the alarm, if still present.

The procedure is complete.


--End--

2.12.92 IPM-USER core (source: IPM temperature)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

IPM-USER core

Source:

(15728675) Temperature

BTS model:

S8000 Indoor + S8000 Outdoor

FAULT ANALYSIS
This alarm indicates an excessively high temperature on an IPM-USER.

REACTION OF THE SYSTEM


BSC defense

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

641

None.
Impact on the service
None.

TROUBLESHOOTING
Procedure 8
Preliminary checks

Step

Action

Check that the alarm on the IPM-USER is valid by performing a


"Display hardware information" command on the IPM object.

ATTENTION
The "Display hardware information" command is not available if a
BTS inventory is already running on the btsSiteManager object.

Look at the result displayed in the "Session log" window.

If the state of the "IPM" equipment is "failed", the fault is


confirmed.

If the state of the "IPM" equipment is "working", the fault is


not confirmed. Go to step 4.

On-site maintenance using the OMC-R

Replace the IPM-USER.


See Nortel GSM BTS S8000/S8003 Troubleshooting
(411-9001-048).

Check the alarm state in the "Current Alarm list" window, and
make sure the alarm has disappeared.

Clear the alarm, if still present.

The procedure is complete.


--End--

2.12.93 IPM-USER core (source: DAC unable to lock, synchronization


not possible)
Fault number 1067

Abis event reporting a hardware fault

Equipment:

IPM-USER core

Source:

(15728688) DAC unable to lock, synchronization not possible

BTS model:

S8000 Indoor + S8000 Outdoor

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

642

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

FAULT ANALYSIS
The IPM-USER generates a "Frequency saturation" event in case the local
oscillator cannot be frequency-locked, within its operational tuning range.
The begin-of fault alarm indicates that the current value of the DAC
(Digital-to-Analog Converter) is not within a nominal range. The DAC
value is not within in this range for a time for that reaches the confirmation
threshold.
The end-of-fault alarm indicates that the current DAC value is within a
nominal range. The DAC value is within in this range for a time for that
reaches the confirmation threshold.
The causes for this alarm are:

The IPM-USER local oscillator has experienced a large frequency


skew with age. It is no more able to lock to the BSC reference clock
within its nominal tuning range. This is the most probable cause.

The network reference frequency is in failure. This is the least probable


cause.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
None.

TROUBLESHOOTING
Procedure 9
Preliminary checks

Step

Action

Check that the alarm on the IPM-USER is valid by performing a


"Display hardware information" command on the IPM object.

ATTENTION
The "Display hardware information" command is not available if a
BTS inventory is already running on the btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

643

Look at the result displayed in the "Session log" window.

If the state of the "IPM" equipment is "failed", the fault is


confirmed.

If the state of the "IPM" equipment is "working", the fault is


not confirmed. Go to step 4.

On-site maintenance using the OMC-R

Replace the IPM-USER.


See Nortel GSM BTS S8000/S8003 Troubleshooting
(411-9001-048).

Check the alarm state in the "Current Alarm list" window, and
make sure the alarm has disappeared.

Clear the alarm, if still present.

The procedure is complete.


--End--

2.12.94 Lightning protector (source: Lightning protection fault)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

Lightning Protection

Source:

(6160385) Lightning protection fault

BTS model:

S8000 Outdoor + S8002 + S8006

FAULT ANALYSIS
This alarm is detected by the ALCO or RECAL board.
This alarm indicates if the lightning protector is operational.

If the BTS operates on its batteries, the lightning protector is faulty.


If the BTS does not operate on its batteries, there is a problem of the
detector.

REACTION OF THE SYSTEM


BSC defense
As long as the BTS works on batteries, there is no BSC defense action.
If the BTS is completely powered off, the BSC detects PCM faults
and unconfigures the btsSiteManager, bts, transceiverEquipment and
transceiver objects.
Impact on the service
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

644

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

CAUTION
Working instructions
Intervention on the site must be immediate: it is possible to lose
the entire site (with potential damages).

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational. Look for
an object whose state is "disabled-failed" and process the
problem in order that the btsSiteManager object becomes
"enabled".
If no object is concerned and if a fault number 1054 (loss
of layer 2) has appeared:

If the cabinet is out of order, process the problem on


the cabinet. Go to step 3.

Otherwise, refer to the fault number 1054 (see


411-9001-105 (Nortel GSM BSS Fault Clearing Advanced Maintenance Procedures) ).

If a pcmCircuit object is "disabled-failed":

If the cabinet is out of order, process the problem on


the cabinet. Go to step 3.

Look for a fault number concerning PCMs (see


411-9001-105 (Nortel GSM BSS Fault Clearing Advanced Maintenance Procedures) ).

If an lapdLink object is "disabled-failed", the BSC is


concerned. Look for alarms concerning the BSC.

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

645

not clear it. Wait for the state of the btsSiteManager


object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 8.

Check that the alarm on the lightning protector is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "Lightning Protection" equipment is "failed",


the fault is confirmed. Go to step 4.

If the state of the "Lightning Protection" equipment is


"working", the fault is not confirmed. Go to step 7.

On-site maintenance

Perform a "Display" command on the btsSiteManager object to


check the value of the parameter "lightning protection".

If the value is "absent", set it to "present". Go to step 5.


If the value is "present", go to step 4.

Replace the lightning protector (Field Replaceable Unit).

For the S8000 BTSs, refer to 411-9001-048 (Nortel GSM BTS


S8000/S8003 Troubleshooting)

For the S8002 BTS, refer to 411-9001-084 (Nortel GSM BTS


S8002 Troubleshooting)

For the S8006 BTS, refer to 411-9001-085 (Nortel GSM BTS


S8006 Troubleshooting)

Go to step 5.
Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 8.


If the alarm persists, go to step 6.

Check the state of the lightning protector by performing


a "Display hardware configuration" command on the
btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

646

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Look at the result displayed in the "Session log" window.

If the state of the "Lightning Protection" equipment is still


"failed", call the manufacturer.

If the state of the "Lightning Protection" equipment is


"working", go to step 7.

Clear the alarm.

The procedure is complete.


--End--

2.12.95 Not protected alarm (source: Alarm)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

not protected alarm

Source:

(3735553) Alarm

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

If the alarm is external, the maintenance action depends on how the


user deals with the alarm. Sixteen external alarms can be used for each
cabinet.

2.12.96 Output Rx-splitter D (source: Over current)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

rx splitter D

Source:

(9764865) Over current

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

ATTENTION
This alarm is treated by either performing the following procedure or by
performing the procedure associated with the TIL and described in:

411-9001-048 (Nortel GSM BTS S8000/S8003 Troubleshooting) for the


S8000 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for the


S8002/S8003 BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for the S8006 BTS

FAULT ANALYSIS

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

647

This alarm corresponds to a fault in the reception amplifier of the diversity


path, located in the Rx-splitter. A current over consumption has been
detected on the diversity path. It can be due to a hardware problem on
the cable.
REACTION OF THE SYSTEM
BSC defense
There is no BSC defense action until the fault occurs on the main path
on the Rx-splitter, at which point the BSC unconfigures at least one
transceiverEquipment object.
Impact on the service

CAUTION
Service reduction
The service is reduced.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

648

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

a. As long as the operationalState of the btsSiteManager


object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 7.

Check that the alarm on the output Rx-splitter D is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "rx splitter D" equipment is "failed", the fault
is confirmed. Go to step 3.

If the state of the "rx splitter D" equipment is "working", the


fault is not confirmed. Go to step 6.

On-site maintenance

Check the cabling between the DRX or DRX-ND3 and the


Rx-splitter.

If it is correct, replace the Rx-splitter (Field Replaceable Unit).


Refer to:
411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting) for the S8000 BTS
411-9001-084 (Nortel GSM BTS S8002 Troubleshooting)
for the S8002 BTS
411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting) for the S8003 BTS
411-9001-085 (Nortel GSM BTS S8006 Troubleshooting)
for the S8006 BTS
Go to step 4.

If it is not correct, replace the cable (Shop Replaceable Unit).


Go to step 4.

Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 7.


If the alarm persists, go to step 5.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

649

Check the state of the output Rx-splitter D by performing


a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "rx splitter D" equipment is still "failed", call
the manufacturer.

If the state of the "rx splitter D" equipment is "working", go to


step 6.

Clear the alarm.

The procedure is complete.


--End--

2.12.97 Output Rx-splitter M (source: Over current)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

rx splitter M

Source:

(9699329) Over current

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

ATTENTION
This alarm is treated by either performing the following procedure or by
performing the procedure associated with the TIL and described in:

411-9001-048 (Nortel GSM BTS S8000/S8003 Troubleshooting) for the


S8000/S8003 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for the S8002 BTS
411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for the S8006 BTS

FAULT ANALYSIS
This alarm corresponds to a fault in the reception amplifier of the main
path, located in the Rx-splitter. A current over consumption has been
detected on the main path. It can be due to a hardware problem on the
cable.
REACTION OF THE SYSTEM
BSC defense
There is no BSC defense action until the fault occurs on the diversity
path on the Rx-splitter, at which point the BSC unconfigures at least one
transceiverEquipment object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

650

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Impact on the service

CAUTION
Service reduction
The service is reduced.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 7.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

651

Check that the alarm on the output Rx-splitter M is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "rx splitter M" equipment is "failed", the fault
is confirmed. Go to step 3.

If the state of the "rx splitter M" equipment is "working", the


fault is not confirmed. Go to step 6.

On-site maintenance

Check the cabling between the DRX or DRX-ND3 and the


Rx-splitter.

If it is correct, replace the Rx-splitter (Field Replaceable Unit).


Refer to:
411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting) for the S8000 BTS
411-9001-084 (Nortel GSM BTS S8002 Troubleshooting)
for the S8002 BTS
411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting) for the S8003 BTS
411-9001-085 (Nortel GSM BTS S8006 Troubleshooting)
for the S8006 BTS
Go to step 4.

If it is not correct, replace the cable (Shop Replaceable Unit).


Go to step 4.

Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 7.


If the alarm persists, go to step 5.

Check the state of the output Rx-splitter M by performing


a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "rx splitter M" equipment is still "failed", call
the manufacturer.

If the state of the "rx splitter M" equipment is "working", go


to step 6.

Clear the alarm.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

652

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

The procedure is complete.


--End--

2.12.98 PCM (source: PCM)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

PCM

Source:

(6488065) PCM

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

This alarm can indicate a manual action on the PCM links (lock/unlock
when the BTS is connected to a BSC 3000).
This alarm can also be associated with a PCM fault. See 411-9001-105
(Nortel GSM BSS Fault Clearing - Advanced Maintenance Procedures)

2.12.99 PCMI boards (source: Major fault on PCMI)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

PCMI

Source:

(4521985) Major fault

BTS model:

S8000 Outdoor + S8000 Indoor

This problem is associated with a PCM fault. See 411-9001-105 (Nortel


GSM BSS Fault Clearing - Advanced Maintenance Procedures)

2.12.100 Power amplifiers (source: Hardware)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

PA or ePA or HePA

Source:

6815745 or 12648449 or 12713985 Hardware

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

This alarm is treated by either performing the following procedure or by


performing the procedure associated with the TIL and described in:

411-9001-048 (Nortel GSM BTS S8000/S8003 Troubleshooting) for the


S8000/S8003 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for the S8002


BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for the S8006


BTS

FAULT ANALYSIS
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

653

This alarm indicates a hardware failure of the (H)(e)PA. The corresponding


TRX is no longer operational.
REACTION OF THE SYSTEM
BSC defense
The BSC unconfigures the transceiverEquipment object using the faulty
(H)(e)PA, at least one transceiver object (therefore one bts object).
Impact on the service

CAUTION
Service reduction
The service is reduced.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

654

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

not clear it. Wait for the state of the btsSiteManager


object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 15.

Check that the alarm on the power amplifier is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "(H)(e)PA" equipment is "failed", the fault is


confirmed. Go to step 3.

If the state of the "(H)(e)PA" equipment is "working", the fault


is not confirmed. Go to step 14.

On-site maintenance using the OMC-R

In the case of an S8000 BTS, perform a "Display" command on


the bts object.
The "standardIndicator" parameter indicates the frequency
band associated with the DRX or DRX-ND3 module: "gsm", "
gsm850", "dcs1800", "pcs1900", "R gsm", "gsmdcs" or "dcsgsm".

If the "standardIndicator" parameter is "gsm 850pcs", perform


a "Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or DRX-ND3 is "gsm850".
If the "transceiverEquipmentClass" parameter is "2", the
DRX or DRX-ND3 is PCS.

If the "standardIndicator" parameter is "pcsgsm850", perform


a "Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or DRX-ND3 is PCS.
If the "transceiverEquipmentClass" parameter is "2", the
DRX or DRX-ND3 is "gsm850".

If the "standardIndicator" parameter is "gsmdcs", perform a


"Display" command on the transceiverEquipment object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

655

If the "transceiverEquipmentClass" parameter is "1", the


DRX or DRX-ND3 is GSM.
If the "transceiverEquipmentClass" parameter is "2", the
DRX or DRX-ND3 is DCS.

If the "standardIndicator" parameter is "dcsgsm", perform a


"Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or DRX-ND3 is DCS.
If the "transceiverEquipmentClass" parameter is "2", the
DRX or DRX-ND3 is GSM.

Note the contents of the additional fields in the notifications and


send these, if any, to the manufacturer with the faulty item.

Check that the switch on the front panel of the (H)(e)PA is in the
"I" position or that the power cable of the (H)(e)PA is connected
to the (H)(e)PA interconnections module.

If this is the case, go to step 8.


If this is not the case, go to step 6.

Perform the following actions:


a Set the transceiverEquipment object to "locked".
b Put the switch of the (H)(e)PA in the "I" position or
connect the power cable of the (H)(e)PA to the (H)(e)PA
interconnection panel.
c Set the transceiverEquipment object to "unlocked".
Check the state of the alarm.

If the alarm has disappeared, go to step 15.


If the alarm persists, go to step 7.

Put the switch of the (H)(e)PA to the "O" position or disconnect


the power cable of the (H)(e)PA from the interconnections
module, and check the fuse of the (H)(e)PA INTERCO unit.

If the fuse is faulty, replace it (Shop Replaceable Unit).


a. Set the transceiverEquipment object to "locked".
b. Put the switch of the (H)(e)PA in the "I" position or
reconnect the power cable of the (H)(e)PA to the
(H)(e)PA interconnections module.
c. Set the transceiverEquipment object to "unlocked".
Check the state of the alarm.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

656

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the alarm has disappeared, go to step 15.

If the alarm persists, go to step 8.

If the fuse is correct, go to step 8.

Check the fuse of the faulty (H)(e)PA.

If the fuse is faulty, replace it (Shop Replaceable Unit).


a. Set the transceiverEquipment object to "locked".
b. Put the switch of the (H)(e)PA in the "I" position
or connect the power cable of the (H)(e)PA to the
interconnections module.
c. Set the transceiverEquipment object to "unlocked".
Check the state of the alarm.

If the alarm has disappeared, go to step 15.

If the alarm persists, go to step 8.

If the fuse is correct, go to step 8.

Perform the following actions:


a Set the administrativeState of the transceiverEquipment
corresponding to the faulty (H)(e)PA to "locked".
b Replace the (H)(e)PA module (Field Replaceable Unit). Refer
to:

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8000 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting)


for the S8002 BTS

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8003 BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting)


for the S8006 BTS

c Set the administrativeState of the transceiverEquipment


corresponding to the faulty (H)(e)PA to "unlocked".

If the alarm has disappeared, go to step 15.


If the alarm persists, check the state of the power
amplifier by performing a "Display hardware configuration"
command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.
If the state of the "(H)(e)PA" equipment is still "failed",
go to step 10.
If the state of the "(H)(e)PA" equipment is "working",
go to step 14.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

10

Check if there is a "Self test failed" alarm on the DRX or


DRX-ND3 connected to the (H)(e)PA.

11

657

If this is the case, go to step 11.


If this is not the case, go to step 12.

Perform the following actions:


a Set the administrativeState of the transceiverEquipment
corresponding to the faulty (H)(e)PA to "locked".
b Remove the newly inserted (H)(e)PA module and reinsert the
old (H)(e)PA module.
c Replace the DRX or DRX-ND3 module (Field Replacement
Unit). Refer to:

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8000 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting)


for the S8002 BTS

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8003 BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting)


for the S8006 BTS

d Set the administrativeState of the transceiverEquipment


corresponding to the faulty (H)(e)PA to "unlocked".

If the alarm has disappeared, go to step 15.


If the alarm persists, check the state of the power
amplifier by performing a "Display hardware configuration"
command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.
If the state of the "(H)(e)PA" equipment is still "failed",
go to step 12.
If the state of the "(H)(e)PA" equipment is "working",
go to step 13.

12

Perform the following actions:


a Set the administrativeState of the transceiverEquipment
corresponding to the faulty (H)(e)PA to "locked".
b Remove the newly inserted DRX or DRX-ND3 module and
reinsert the old DRX or DRX-ND3 module.
c Set the administrativeState of the transceiverEquipment
corresponding to the faulty (H)(e)PA to "unlocked".
d Check the cables and the connectors between the (H)(e)PAs
and the DRX or DRX-ND3s.
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

658

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If they are correctly tightened, go to step 13.


If they are not correctly tightened, tighten them.
If the alarm has disappeared, go to step 15.
If the alarm persists, go to step 13.

Additional checks

13

Check the state of the power amplifier by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "(H)(e)PA" equipment is still "failed", call the


manufacturer.

If the state of the "(H)(e)PA" equipment is "working", go to


step 14.

14

Clear the alarm.

15

The procedure is complete.


--End--

2.12.101 Power amplifiers (source: DRX and PA connection)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

PA or ePA or HePA

Source:

6815746 or 12648450 or 12713986: DRX and PA


connection

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

This alarm is treated by either performing the following procedure or by


performing the procedure associated with the TIL and described in:

411-9001-048 (Nortel GSM BTS S8000/S8003 Troubleshooting) for the


S8000/S8003 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for the S8002


BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for the S8006


BTS

FAULT ANALYSIS
This alarm indicates that the numeric link is out of use between the DRX or
DRX-ND3 and the (H)(e)PA. The TRX is no longer operational.
REACTION OF THE SYSTEM
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

659

BSC defense
The BSC unconfigures the transceiverEquipment object using the faulty
(H)(e)PA, at least one transceiver object (therefore one bts object).
Impact on the service

CAUTION
Service reduction
The service is reduced.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

660

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

object to become "enabled", "disabled-dependency", or


"disabled-failed".
b.

As soon as the site is operational (the operationalState


of the btsSiteManager object will be "enabled"), check if
the alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 14.

Check that the alarm on the power amplifier is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "(H)(e)PA" equipment is "failed", the fault is


confirmed. Go to step 3.

If the state of the "(H)(e)PA" equipment is "working", the fault


is not confirmed. Go to step 13.

On-site maintenance using the OMC-R

In the case of an S8000 BTS, perform a "Display" command on


the bts object.
The "standardIndicator" parameter indicates the frequency
band associated with the DRX or DRX-ND3 module: "gsm", "
gsm850", "dcs1800", "pcs1900", "R gsm", "gsmdcs" or "dcsgsm".

If the "standardIndicator" parameter is "gsm 850pcs", perform


a "Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or DRX-ND3 is "gsm850".
If the "transceiverEquipmentClass" parameter is "2", the
DRX or DRX-ND3 is PCS.

If the "standardIndicator" parameter is "pcsgsm850", perform


a "Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or DRX-ND3 is PCS.
If the "transceiverEquipmentClass" parameter is "2", the
DRX or DRX-ND3 is "gsm850".

If the "standardIndicator" parameter is "gsmdcs", perform a


"Display" command on the transceiverEquipment object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

661

If the "transceiverEquipmentClass" parameter is "1", the


DRX or DRX-ND3 is GSM.
If the "transceiverEquipmentClass" parameter is "2", the
DRX or DRX-ND3 is DCS.

If the "standardIndicator" parameter is "dcsgsm", perform a


"Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or DRX-ND3 is DCS.
If the "transceiverEquipmentClass" parameter is "2", the
DRX or DRX-ND3 is GSM.

Note the contents of the additional fields in the notifications and


send these, if any, to the manufacturer with the faulty item.

Ensure the switch on the front panel of the (H)(e)PA is in the "I"
position.

If this is the case, go to step 6.


If this is not the case, go to step 7.

Put the switch of the (H)(e)PA in the "O" position or connect the
power cable of the (H)(e)PA to the interconnections module, and
check the fuse of the (H)(e)PA INTERCO unit.

If the fuse is faulty, replace it (Shop Replaceable Unit).


If the alarm has disappeared, go to step 14.
If the alarm persists, go to step 7.

If the fuse is correct, go to step 7.

Check the fuse of the faulty (H)(e)PA.

If the fuse is faulty, replace it (Shop Replaceable Unit).


If the alarm has disappeared, go to step 14.
If the alarm persists, go to step 8.

If the fuse is correct, go to step 8.

Perform the following actions:


a

Set the administrativeState of the transceiverEquipment


corresponding to the faulty (H)(e)PA to "locked".

Replace the (H)(e)PA module (Field Replaceable Unit).


Refer to:

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8000 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting)


for the S8002 BTS

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

662

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8003 BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting)


for the S8006 BTS

Set the administrativeState of the transceiverEquipment


corresponding to the faulty (H)(e)PA to "unlocked".

If the alarm has disappeared, go to step 14.


If the alarm persists, check the state of the power
amplifier by performing a "Display hardware configuration"
command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.
If the state of the "(H)(e)PA" equipment is still "failed",
go to step 9.
If the state of the "(H)(e)PA" equipment is "working",
go to step 13.

Perform the following actions:


a Set the administrativeState of the transceiverEquipment
corresponding to the faulty (H)(e)PA to "locked".
b

Remove the newly inserted (H)(e)PA module and reinsert the


old (H)(e)PA module.

Set the administrativeState of the transceiverEquipment


corresponding to the faulty (H)(e)PA to "unlocked".

Check the cables and the connectors between the (H)(e)PAs


and the DRX or DRX-ND3s.

If they are correctly tightened, go to step 10.


If they are not correctly tightened, tighten them.
If the alarm has disappeared, go to step 14.
If the alarm persists, go to step 10.

10

Perform the following actions:


a

Set the administrativeState of the transceiverEquipment


corresponding to the faulty (H)(e)PA to "locked".

Replace the DRX or DRX-ND3 module (Field Replacement


Unit). Refer to:

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8000 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting)


for the S8002 BTS

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

663

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8003 BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting)


for the S8006 BTS

Set the administrativeState of the transceiverEquipment


corresponding to the faulty (H)(e)PA to "unlocked".

Go to step 11.

Additional checks

11

Check the alarm state in the "Current Alarm list" window.

12

If the alarm has disappeared, go to step 14.


If the alarm persists, go to step 12.

Check the state of the power amplifier by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "(H)(e)PA" equipment is still "failed", call the


manufacturer.

If the state of the "(H)(e)PA" equipment is "working", go to


step 13.

13

Clear the alarm.

14

The procedure is complete.


--End--

2.12.102 Power amplifiers (source: High temperature )


Fault number 1067

Abis event reporting a hardware fault

Equipment:

PA or ePA or HePA

Source:

6815747 or 12648451 or 12713987: High temp

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

This alarm is treated by either performing the following procedure or by


performing the procedure associated with the TIL and described in:

411-9001-048 (Nortel GSM BTS S8000/S8003 Troubleshooting) for the


S8000/S8003 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for the S8002


BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for the S8006


BTS

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

664

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

FAULT ANALYSIS
This alarm indicates an excessively high temperature on the (H)(e)PA.
REACTION OF THE SYSTEM
BSC defense
The BSC unconfigures the transceiverEquipment object using the faulty
(H)(e)PA, at least one transceiver object (therefore one bts object).
Impact on the service

CAUTION
Service reduction
The service is reduced.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

665

a. As long as the operationalState of the btsSiteManager


object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b.

As soon as the site is operational (the operationalState


of the btsSiteManager object will be "enabled"), check if
the alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 10.

Check that the alarm on the power amplifier is valid by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "(H)(e)PA" equipment is "failed", the fault is


confirmed. Go to step 3.

If the state of the "(H)(e)PA" equipment is "working", the fault


is not confirmed. Go to step 9.

On-site maintenance using the OMC-R

Perform a "Display" command on the bts object.


The "standardIndicator" parameter indicates the frequency
band associated with the DRX or DRX-ND3 module: "gsm", "
gsm850", "dcs1800", "pcs1900", "R gsm", "gsmdcs" or "dcsgsm".

If the "standardIndicator" parameter is "gsm 850pcs", perform


a "Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or DRX-ND3 is "gsm850".
If the "transceiverEquipmentClass" parameter is "2", the
DRX or DRX-ND3 is PCS.

If the "standardIndicator" parameter is "pcsgsm850", perform


a "Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or DRX-ND3 is PCS.
If the "transceiverEquipmentClass" parameter is "2", the
DRX or DRX-ND3 is "gsm850".

If the "standardIndicator" parameter is "gsmdcs", perform a


"Display" command on the transceiverEquipment object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

666

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the "transceiverEquipmentClass" parameter is "1", the


DRX or DRX-ND3 is GSM.
If the "transceiverEquipmentClass" parameter is "2", the
DRX or DRX-ND3 is DCS.

If the "standardIndicator" parameter is "dcsgsm", perform a


"Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or DRX-ND3 is DCS.
If the "transceiverEquipmentClass" parameter is "2", the
DRX or DRX-ND3 is GSM.

Note the contents of the additional fields in the notifications and


send these, if any, to the manufacturer with the faulty item.

Checks
Ensure the cabinet door is closed.
a

If it is closed, go to the next check.

If it is not closed, close it. Allow an appropriate amount of


time for the temperature to decrease. Go to step 7.

Check the running of the DACS climatic system (S8000 Outdoor)


or the Fan (S8000 Indoor, S8002, S8003, and S8006).
a

If it is correct, go to the next check.

If it is not correct, perform a corrective action on the DACS


(S8000 Outdoor) or the Fan (S8000 Indoor, S8002, S8003,
and S8006). Go to step 7.

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 9.

If the alarm persists, go to step 6.

FRU replacement
a Switch the transceiverEquipment object corresponding to the
faulty (H)(e)PA to "locked".

CAUTION
Service reduction
In most cases, the TRX and one TDMA are lost.
The service is reduced.

b Replace the faulty (H)(e)PA according to the replacement


procedure. Refer to:

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

667

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8000 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting)


for the S8002 BTS

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8003 BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting)


for the S8006 BTS

c Switch the transceiverEquipment object corresponding to the


replaced (H)(e)PA to "unlocked".
d

Make sure that the fault has been cleared (the alarms are
transferred to the alarm history file of the OMC-R).

Go to step 10.

Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 10.


If the alarm persists, go to step 8.

Check the state of the power amplifier by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "(H)(e)PA" equipment is still "failed", call the


manufacturer.

If the state of the "(H)(e)PA" equipment is "working", go to


step 9.

Clear the alarm.

10

The procedure is complete.


--End--

2.12.103 Power amplifiers (source: High Current )


Fault number 1067

Abis event reporting a hardware fault

Equipment:

PA or ePA or HePA

Source:

6815748 or 12648452 or 12713988: High Current

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

This alarm is treated by either performing the following procedure or by


performing the procedure associated with the TIL and described in:

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

668

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

411-9001-048 (Nortel GSM BTS S8000/S8003 Troubleshooting) for the


S8000/S8003 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for the S8002


BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for the S8006


BTS

FAULT ANALYSIS
This alarm indicates errors concerning the (H)(e)PA power supply.
It concerns the following errors:

errors on the DC/DC converters of the (H)(e)PA


errors of an excessive power consumption of the (H)(e)PA

REACTION OF THE SYSTEM


BSC defense
The BSC unconfigures the transceiverEquipment object using the faulty
(H)(e)PA, at least one transceiver object (therefore one bts object).
Impact on the service

CAUTION
Service reduction
The service is reduced.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

669

GSM BSS Fault Clearing - Advanced Maintenance


Procedures) ).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 9.

Check that the alarm on the power amplifier is valid by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "(H)(e)PA" equipment is "failed", the fault is


confirmed. Go to step 3.

If the state of the "(H)(e)PA" equipment is "working", the fault


is not confirmed. Go to step 8.

On-site maintenance using the OMC-R

Perform a "Display" command on the bts object.


The "standardIndicator" parameter indicates the frequency
band associated with the DRX or DRX-ND3 module: "gsm", "
gsm850", "dcs1800", "pcs1900", "R gsm", "gsmdcs" or "dcsgsm".

If the "standardIndicator" parameter is "gsm 850pcs", perform


a "Display" command on the transceiverEquipment object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

670

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the "transceiverEquipmentClass" parameter is "1", the


DRX or DRX-ND3 is "gsm850".
If the "transceiverEquipmentClass" parameter is "2", the
DRX or DRX-ND3 is PCS.

If the "standardIndicator" parameter is "pcsgsm850", perform


a "Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or DRX-ND3 is PCS.
If the "transceiverEquipmentClass" parameter is "2", the
DRX or DRX-ND3 is "gsm850".

If the "standardIndicator" parameter is "gsmdcs", perform a


"Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or DRX-ND3 is GSM.
If the "transceiverEquipmentClass" parameter is "2", the
DRX or DRX-ND3 is DCS.

If the "standardIndicator" parameter is "dcsgsm", perform a


"Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or DRX-ND3 is DCS.
If the "transceiverEquipmentClass" parameter is "2", the
DRX or DRX-ND3 is GSM.

Note the contents of the additional fields in the notifications and


send these, if any, to the manufacturer with the faulty item.

FRU replacement
a

Switch the transceiverEquipment object corresponding to the


faulty (H)(e)PA to "locked".

CAUTION
Service reduction
In most cases, the TRX and one TDMA are lost.
The service is reduced.

Replace the faulty (H)(e)PA according to the replacement


procedure. Refer to:

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8000 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting)


for the S8002 BTS

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

671

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8003 BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting)


for the S8006 BTS

Switch the transceiverEquipment object corresponding to the


replaced (H)(e)PA to "unlocked".

Make sure that the fault has been cleared (the alarms are
transferred to the alarm history file of the OMC-R).

Go to step 9.

Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 9.


If the alarm persists, go to step 7.

Check the state of the power amplifier by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "(H)(e)PA" equipment is still "failed", call the


manufacturer.

If the state of the "(H)(e)PA" equipment is "working", go to


step 8.

Clear the alarm.

The procedure is complete.


--End--

2.12.104 Power amplifiers (source: PA_PSDW )


Fault number 1067

Abis event reporting a hardware fault

Equipment:

PA or ePA or HePA

Source:

6815750 or 12648454 or 12713990: PA_PSDW

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

This alarm is treated by either performing the following procedure or by


performing the procedure associated with the TIL and described in:

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

672

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

411-9001-048 (Nortel GSM BTS S8000/S8003 Troubleshooting) for the


S8000/S8003 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for the S8002


BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for the S8006


BTS

FAULT ANALYSIS
This alarm indicates an excessively high input level on the (H)(e)PA.
REACTION OF THE SYSTEM
BSC defense
The BSC unconfigures the transceiverEquipment object using the faulty
(H)(e)PA, at least one transceiver object (therefore one bts object).
Impact on the service

CAUTION
Service reduction
The service is reduced.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

673

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b.

As soon as the site is operational (the operationalState


of the btsSiteManager object will be "enabled"), check if
the alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 10.

Check that the alarm on the power amplifier is valid by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "(H)(e)PA" equipment is "failed", the fault is


confirmed. Go to step 3.

If the state of the "(H)(e)PA" equipment is "working", the fault


is not confirmed. Go to step 9.

On-site maintenance using the OMC-R

Perform a "Display" command on the bts object.


The "standardIndicator" parameter indicates the frequency
band associated with the DRX or DRX-ND3 module: "gsm", "
gsm850", "dcs1800", "pcs1900", "R gsm", "gsmdcs" or "dcsgsm".

If the "standardIndicator" parameter is "gsm 850pcs", perform


a "Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or DRX-ND3 is "gsm850".
If the "transceiverEquipmentClass" parameter is "2", the
DRX or DRX-ND3 is PCS.

If the "standardIndicator" parameter is "pcsgsm850", perform


a "Display" command on the transceiverEquipment object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

674

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the "transceiverEquipmentClass" parameter is "1", the


DRX or DRX-ND3 is PCS.
If the "transceiverEquipmentClass" parameter is "2", the
DRX or DRX-ND3 is "gsm850".

If the "standardIndicator" parameter is "gsmdcs", perform a


"Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or DRX-ND3 is GSM.
If the "transceiverEquipmentClass" parameter is "2", the
DRX or DRX-ND3 is DCS.

If the "standardIndicator" parameter is "dcsgsm", perform a


"Display" command on the transceiverEquipment object.
If the "transceiverEquipmentClass" parameter is "1", the
DRX or DRX-ND3 is DCS.
If the "transceiverEquipmentClass" parameter is "2", the
DRX or DRX-ND3 is GSM.

Note the contents of the additional fields in the notifications and


send these, if any, to the manufacturer with the faulty item.

Checks
a

Check the RF cables between the DRX or DRX-ND3 and the


(H)(e)PA.

If necessary tighten the RF cables.

CAUTION
Tightening torques
The tightening torque of the terminal "RF IN" must
be 0.7 N-m 0.1. Use the 8-mm SMA torque
wrench.
The tightening torque of the terminal "RF OUT"
must be 1.5 N-m 0.1. Use the 19-mm N torque
wrench.

If the alarm persists, go to step 6.


If the alarm disappears, go to step 10.

FRU replacement
a

Switch the transceiverEquipment object corresponding to the


faulty (H)(e)PA to "locked".

CAUTION
Service reduction
In most cases, the TRX and one TDMA are lost.
The service is reduced.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

675

Replace the faulty (H)(e)PA according to the replacement


procedure. Refer to:

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8000 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting)


for the S8002 BTS

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8003 BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting)


for the S8006 BTS

Switch the transceiverEquipment object corresponding to the


replaced (H)(e)PA to "unlocked".

Make sure that the fault has been cleared (the alarms are
transferred to the alarm history file of the OMC-R).

Go to step 10.

Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 10.


If the alarm persists, go to step 8.

Check the state of the power amplifier by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "(H)(e)PA" equipment is still "failed", call the


manufacturer.

If the state of the "(H)(e)PA" equipment is "working", go to


step 9.

Clear the alarm.

10

The procedure is complete.


--End--

2.12.105 Power amplifiers (source: VSWR fault detected by PA)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

PA

Source:

6815751: VSWR fault detected by PA

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

676

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

FAULT ANALYSIS
This alarm indicates that the PA has detected a VSWR fault and it has
stopped to emit.

REACTION OF THE SYSTEM


BSC defense The BSC unconfigures the transceiverEquipment object
using the faulty PA, at least one transceiver object (therefore one bts
object).

CAUTION
Service reduction
The service is reduced.

TROUBLESHOOTING
This alarm is treated by performing the procedure associated with the TIL
and described in:

411-9001-048 (Nortel GSM BTS S8000/S8003 Troubleshooting) for


the S8000 BTS

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for the S8002


BTS

411-9001-048 (Nortel GSM BTS S8000/S8003 Troubleshooting) for


the S8003 BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for the S8006


BTS

2.12.106 RECAL board (source: Major)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

RECAL

Source:

(9633793) Major

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
This alarm indicates that the active CMCF board has lost the connection
with the RECAL board.
REACTION OF THE SYSTEM
BSC defense
None.
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

677

Impact on the service


The BTS no longer supervises the equipment linked to its RECAL board
(distribution system, rectifiers, F-type converters, internal batteries, climatic
system, LNA, VSWR, door contact, lightning protection, battery cabinet).
Therefore, the S12000 BTS service is not supervised, as the BTS cannot
inform the BSC.

CAUTION
Service interruption
There is a risk of service loss, even though the OMC-R does not
indicate any loss.

CAUTION
Working instructions
Intervention on the site must be immediate.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

678

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

a. As long as the operationalState of the btsSiteManager


object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 8.

Check that the alarm on the RECAL board is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "RECAL" equipment is "failed", the fault is


confirmed. Go to step 3.

If the state of the "RECAL" equipment is "working", the fault is


not confirmed. Go to step 7.

On-site maintenance

Check the RECAL board fuse on the CBCF front panel for the
S8000 Outdoor BTS or the RECAL/CBCF circuit breaker for the
S8000 Indoor BTS.

If it is correct, go to step 4.
If it is not correct, replace it (Shop Replaceable Unit). Go to
step 5.

Check the power supply voltage on the PWR cable by measuring


with a voltmeter.

If the voltage is lower than -58V and higher than -40V,


replace the RECAL board (Field Replaceable Unit). Refer to:
411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting) for the S8000 BTS
411-9001-084 (Nortel GSM BTS S8002 Troubleshooting)
for the S8002 BTS
411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting) for the S8003 BTS
411-9001-085 (Nortel GSM BTS S8006 Troubleshooting)
for the S8006 BTS

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

679

Go to step 5.

If the voltage is between -58V and -40V, replace the cable


(Shop Replaceable Unit) between the CBCF and the RECAL
board. Go to step 5.

Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 8.


If the alarm persists, go to step 6.

Check the state of the RECAL board by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "RECAL" equipment is still "failed", call the


manufacturer.

If the state of the "RECAL" equipment is "working", go to step


7.

Clear the alarm.

The procedure is complete.


--End--

2.12.107 RECAL board (source: Slave downloading error)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

RECAL

Source:

(9699322) Slave downloading error

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
This alarm indicates an error during the downloading sequence of the
RECAL board by the active CMCF board.
REACTION OF THE SYSTEM
BSC defense
None.
Impact on the service

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

680

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

The BTS no longer supervises the equipment linked to its RECAL board
(distribution system, rectifiers, F-type converters, internal batteries, climatic
system, LNA, VSWR, door contact, lightning protection, battery cabinet).
Therefore, the S12000 BTS service is not supervised, as the BTS cannot
inform the BSC.

CAUTION
Service interruption
There is a risk of service loss, even though the OMC-R does not
indicate any loss.

CAUTION
Working instructions
Intervention on the site must be immediate.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

681

object to become "enabled", "disabled-dependency", or


"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 8.

Check that the alarm on the RECAL board is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "RECAL" equipment is "failed", the fault is


confirmed. Go to step 3.

If the state of the "RECAL" equipment is "working", the fault is


not confirmed. Go to step 7.

On-site maintenance

Check the RECAL board fuse on the CBCF front panel for the
S8000 Outdoor BTS or the RECAL/CBCF circuit breaker for the
S8000 Indoor BTS.

If it is correct, go to step 4.
If it is not correct, replace it (Shop Replaceable Unit). Go to
step 5.

Check the power supply voltage on the PWR cable by measuring


with a voltmeter.

If the voltage is lower than -58V and higher than -40V,


replace the RECAL board (Field Replaceable Unit). Refer to:
411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting) for the S8000 BTS
411-9001-084 (Nortel GSM BTS S8002 Troubleshooting)
for the S8002 BTS
411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting) for the S8003 BTS
411-9001-085 (Nortel GSM BTS S8006 Troubleshooting)
for the S8006 BTS
Go to step 5.

If the voltage is between -58V and -40V, replace the cable


(Shop Replaceable Unit) between the CBCF and the RECAL
board. Go to step 5.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

682

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers


Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 8.


If the alarm persists, go to step 6.

Check the state of the RECAL board by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "RECAL" equipment is still "failed", call the


manufacturer.

If the state of the "RECAL" equipment is "working", go to step


7.

Clear the alarm.

The procedure is complete.


--End--

2.12.108 Rectifiers (source: AC fault)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

rectifier 48V

Source:

(5242881) AC fault

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8006

FAULT ANALYSIS
This alarm is detected by the ALCO or RECAL board.
The cabinet may be operating on its batteries. If so, the fault number
1060 with source "Battery on discharges" is displayed. This is followed by
another source "External battery level 1" if the battery charge has dropped
below the 45V threshold (see source "External battery level 1").
If the cabinet is not operating on its batteries, the problem may be with
either the rectifiers, the link with the ALCO or RECAL board, or with the
ALCO or RECAL board itself.
REACTION OF THE SYSTEM
BSC defense
As long as the BTS is powered on, there is no BSC defense action.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

683

As soon as the BTS is not powered on, the BSC unconfigures the
btsSiteManager object or the bts site or the transceiverEquipment objects.
Impact on the service

CAUTION
Service interruption
If the BTS is powered on, there is no impact. If the BTS is
powered off, the service is reduced and could be lost.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

684

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the alarm persists, go to step 2.

Otherwise, go to step 11.

Check that the alarm on the rectifier is valid, by performing


a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "rectifier 48V" equipment is "failed", the fault


is confirmed. Go to step 3.

If the state of the "rectifier 48V" equipment is "working", the


fault is not confirmed. Go to step 10.

On-site maintenance

If the source is "AC fault" (always accompanied by a fault


notification with the source "DC fault"), check that the main circuit
breaker and the rectifier breaker are not in the "O" position.

If this is the case, put them in the "I" position. Go to step 4.


Otherwise, go to step 4.

Check if the source "AC fault" is accompanied by a fault on the


climatic unit.

If this is the case, the AC power distribution system is


responsible. Solve the problem. Go to step 7.

Otherwise, go to step 5.

Check that the red LED of the rectifier is on and the green LED
is off.

If it is, replace the rectifier (Field Replaceable Unit). Refer to:


411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting) for an S8000 BTS with rectifiers of the
six-rectifier type or for an S8000 BTS with rectifiers of the
seven-rectifier type
411-9001-084 (Nortel GSM BTS S8002 Troubleshooting)
for the S8002 BTS
411-9001-085 (Nortel GSM BTS S8006 Troubleshooting)
for the S8006 BTS
Go to step 8.

Otherwise, go to step 6.

Check the power supply circuit between the main circuit breaker
and the rectifier breaker.

If it is correct, replace the rectifier (Field Replaceable Unit).


Refer to:

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

685

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for an S8000 BTS with rectifiers of the
six-rectifier type or for an S8000 BTS with rectifiers of the
seven-rectifier type
411-9001-084 (Nortel GSM BTS S8002 Troubleshooting)
for the S8002 BTS
411-9001-085 (Nortel GSM BTS S8006 Troubleshooting)
for the S8006 BTS
Go to step 8.

Otherwise, go to step 7.

Check successively the main circuit breaker, the lightning


protector, the filters, and the external power supply circuits
between the site circuit breaker and cabinet.

If the main circuit breaker is not correct:


For an S8000 BTS, replace the main circuit breaker (Field
Replaceable Unit). Refer to 411-9001-048 (Nortel GSM
BTS S8000/S8003 Troubleshooting).
For an S8002 BTS, replace the C-AC box (Field
Replaceable Unit). Refer to 411-9001-084 (Nortel GSM
BTS S8002 Troubleshooting).
For an S8006 BTS, replace the main circuit breaker (Field
Replaceable Unit). Refer to 411-9001-085 (Nortel GSM
BTS S8006 Troubleshooting).
Go to step 8.

Otherwise, if the lightning protector is not correct, replace it


(Field Replaceable Unit).
For the S8000 BTSs, refer to 411-9001-048 (Nortel GSM
BTS S8000/S8003 Troubleshooting)
For the S8002 BTS, refer to 411-9001-084 (Nortel GSM
BTS S8002 Troubleshooting)
For the S8006 BTS, refer to 411-9001-085 (Nortel GSM
BTS S8006 Troubleshooting)
Go to step 8.

Otherwise, check the filters and the external power supply


circuits between the site circuit breaker and cabinet. Replace
them (Shop Replaceable Unit) if needed. Go to step 8.

Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 11.


If the alarm persists, go to step 9.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

686

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Check the state of the rectifier by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "rectifier 48V" equipment is still "failed", call


the manufacturer.

If the state of the "rectifier 48V" equipment is "working", go


to step 10.

10

Clear the alarm.

11

The procedure is complete.


--End--

2.12.109 Rectifiers (source: DC fault)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

rectifier 48V

Source:

(5242882) DC fault

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8006

FAULT ANALYSIS
This alarm is detected by the ALCO or RECAL board.
If the only source is "DC fault" (no other fault notifications concerning the
rectifiers), there is a problem on one rectifier.
REACTION OF THE SYSTEM
BSC defense
None.
Impact on the service
None.
TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.

687

If a fault number 1054 (loss of layer 2) has appeared,


refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 7.

Check that the alarm on the rectifier is valid, by performing


a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "rectifier 48V" equipment is "failed", the fault


is confirmed. Go to step 3.

If the state of the "rectifier 48V" equipment is "working", the


fault is not confirmed. Go to step 6.

On-site maintenance

Identify the faulty rectifier by looking for the rectifier that has the
red led on and the green led off.

If this is not the case, replace the rectifier (Field Replaceable


Unit). Refer to:

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

688

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8000 BTS with rectifiers of the
six-rectifier type or for the S8000 BTS with rectifiers of the
seven-rectifier type
411-9001-084 (Nortel GSM BTS S8002 Troubleshooting)
for the S8002 BTS
411-9001-085 (Nortel GSM BTS S8006 Troubleshooting)
for the S8006 BTS
Go to step 4.

If this is the case, call the manufacturer.

Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 7.


If the alarm persists, go to step 5.

Check the state of the rectifier by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "rectifier 48V" equipment is still "failed", call


the manufacturer.

If the state of the "rectifier 48V" equipment is "working", go


to step 6.

Clear the alarm.

The procedure is complete.


--End--

2.12.110 Rectifiers (source: Over temperature)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

rectifier 48V

Source:

(5242883) Over temperature

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8006

FAULT ANALYSIS
This alarm is detected by the ALCO or RECAL board.
This alarm indicates a temperature problem on the rectifier. When the
temperature is equal to the threshold value (this value depends on each
rectifier and on the adjustment of the rectifier), the rectifier self-protects
and turns off.
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

689

REACTION OF THE SYSTEM


BSC defense
As long as the BTS is powered on, there is no BSC defense action.
As soon as the BTS is powered off, the BSC unconfigures the
btsSiteManager object, the bts object, or the transceiverEquipment objects.
Impact on the service

CAUTION
Service interruption
If this alarm occurs on the base cabinet, there is a loss of
communications and the service is completely reduced.

CAUTION
Working instructions

If the cabinet has a redundant rectifier and if only on rectifier


is faulty, the cabinet continues to function. However, the
faulty rectifier must be replaced.

If the cabinet does not have a redundant rectifier, the


batteries take over from the faulty rectifier(s). Intervention
on the site depends on the discharge time of the batteries
(see 411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting) Paragraph 3.2.3.3).

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

690

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 7.

Check that the alarm on the rectifier is valid, by performing


a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "rectifier 48V" equipment is "failed", the fault


is confirmed. Go to step 3.

If the state of the "rectifier 48V" equipment is "working", the


fault is not confirmed. Go to step 6.

On-site maintenance

Replace the faulty rectifier (Field Replaceable Unit). Refer to:

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for the S8000 BTS with rectifiers of the
six-rectifier type or for the S8000 BTS with rectifiers of the
seven-rectifier type

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for


the S8002 BTS

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting) for


the S8006 BTS

Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 7.


If the alarm persists, go to step 5.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

691

Check the state of the rectifier by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "rectifier 48V" equipment is still "failed", call


the manufacturer.

If the state of the "rectifier 48V" equipment is "working", go


to step 6.

Clear the alarm.

The procedure is complete.


--End--

2.12.111 Rectifiers (source: External battery level 1)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

rectifier 48V

Source:

(5242884) External battery level 1

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
This alarm is detected by the ALCO or RECAL board.
This alarm can occur if the batteries are not powered when the cabinet
starts up.
This alarm appears after a "Battery on discharges" alarm (fault number
1060), which means that the battery discharge has dropped below the
lower threshold (45V). The (H)(e)PAs, the F-type converters and the DRX
or DRX-ND3s are no longer powered.

REACTION OF THE SYSTEM


BSC defense As long as the BTS is powered on, there is no BSC
defense action.
As soon as the BTS is powered off, the BSC unconfigures the
btsSiteManager object and the transceiverEquipment objects.

CAUTION
Service interruption
Below the 42V threshold, the -48V power supply cuts off and
the BTS/BSC link is lost.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

692

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures)).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 7.

Check that the alarm on the rectifier is valid, by performing


a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "rectifier 48V" equipment is "failed", the fault


is confirmed. Go to step 3.

If the state of the "rectifier 48V" equipment is "working", the


fault is not confirmed. Go to step 6.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

693

On-site maintenance

Put the battery circuit breaker on the front panel in the "I"
position, if necessary.

Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 7.


If the alarm persists, go to step 5.

Check the state of the rectifier by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "rectifier 48V" equipment is still "failed", call


the manufacturer.

If the state of the "rectifier 48V" equipment is "working", go


to step 6.

Clear the alarm.

The procedure is complete.


--End--

2.12.112 Rectifiers (source: PCU protective)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

rectifier 48V

Source:

(5242885) PCU protective

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8006

FAULT ANALYSIS
This alarm is detected by the ALCO or RECAL board.
This alarm indicates a fault on the circuit breaker L1/CB1 or L3/CB3 of the
PCU (for the rectifier shelf) or the (H)(e)PA and DRX or DRX-ND3 of the
DCU (for the GIPS).
REACTION OF THE SYSTEM
BSC defense
The BSC unconfigures the transceiverEquipment object and one or several
bts objects.
Impact on the service

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

694

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

CAUTION
Service reduction
The service is reduced.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 13.

Check that the alarm on the rectifier is valid, by performing


a "Display hardware configuration" command on the
btsSiteManager object.
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

695

Look at the result displayed in the "Session log" window.

If the state of the "rectifier 48V" equipment is "failed", the fault


is confirmed. Go to step 3.

If the state of the "rectifier 48V" equipment is "working", the


fault is not confirmed. Go to step 12.

On-site maintenance
It is necessary to check all the equipment located behind the circuit breakers.

Put the circuit breakers L1/CB1 and L3/CB3 in the "O" position.

Put the circuit breaker L1/CB1 (PA for the GIPS) in the "I"
position.

If there is a new break, the cabling between the PCU


(DCU for the GIPS) and the (H)(e)PAs, or the (H)(e)PAs
themselves, are failed. Replace these cables (Shop
Replaceable Unit). Go to step 10.

Otherwise, go to step 5.

Power off the (H)(e)PAs and the F-type converters. Go to step 6.

Successively power on the F-type converters and then the


(H)(e)PAs.

If there is a new break, the last module powered on is failed.


Replace this module (Field Replaceable Unit). Refer to:
411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting) for the S8000 BTS if the faulty module
is an F-type converter or if the faulty module is a power
amplifier.

If the alarm has disappeared, go to step 13.

If the alarm persists, go to step 7.

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting)


for the S8002 BTS if the faulty module is an F-type
converter or if the faulty module is a power amplifier.

If the alarm has disappeared, go to step 13.

If the alarm persists, go to step 7.

411-9001-085 (Nortel GSM BTS S8006 Troubleshooting)


for the S8006 BTS if the faulty module is an F-type
converter or if the faulty module is a power amplifier.

If the alarm has disappeared, go to step 13.

If the alarm persists, go to step 7.

Otherwise, go to step 7.

Put the circuit breaker L3/CB3 (DRX or DRX-ND3 for the GIPS)
in the "I" position.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

696

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If there is a new break, the cabling between the PCU (DCU


for the GIPS) and the DRX or DRX-ND3s, themselves, are
failed. Replace these cables (Shop Replaceable Unit). Go
to step 10.

Otherwise, go to step 8.

Disconnect all the PWR cables from the front panel of the DRX
or DRX-ND3s (cable on the INTERCO panel first, then on the
DRX or DRX-ND3). Go to step 9.

Successively reconnect the PWR cables on the front panel of the


DRX or DRX-ND3s (cable on the DRX or DRX-ND3 first, then
on the INTERCO panel).

If there is a new break, the last module is failed. Replace this


module: cable (Shop Replaceable Unit) or DRX or DRX-ND3
module (Field Replaceable Unit). Refer to:
411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting) for the S8000 BTS DRX or DRX-ND3
module
411-9001-084 (Nortel GSM BTS S8002 Troubleshooting)
for the S8002 BTS DRX or DRX-ND3 module
411-9001-085 (Nortel GSM BTS S8006 Troubleshooting)
for the S8006 BTS DRX or DRX-ND3 module
Go to step 10.

Otherwise, go to step 10.

Additional checks

10

Check the alarm state in the "Current Alarm list" window.

11

If the alarm has disappeared, go to step 13.


If the alarm persists, go to step 11.

Check the state of the rectifier by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "rectifier 48V" equipment is still "failed", call


the manufacturer.

If the state of the "rectifier 48V" equipment is "working", go


to step 12.

12

Clear the alarm.

13

The procedure is complete.


--End--

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

697

2.12.113 Rectifiers (source: Battery on discharges)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

rectifier 48V

Source:

(5242886) Battery on discharges

BTS model:

S8000 Outdoor + S8000 Indoor + S8002

FAULT ANALYSIS
This alarm is detected by the ALCO or RECAL board.
This notification occurs when the system switches to the batteries. It
indicates that the battery is discharging. If the voltage drops below the 45
V threshold, a fault notification with the source "External battery level 1" is
issued.
The fault is caused by an AC and/or a DC failure.
REACTION OF THE SYSTEM
BSC defense
As long as the BTS is powered on, there is no BSC defense action.
As soon as the BTS is powered off, the BSC unconfigures the
btsSiteManager object, the bts object, or the transceiverEquipment objects.
Impact on the service

CAUTION
Service reduction
The service is reduced.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

698

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If a fault number 1054 (loss of layer 2) has appeared,


refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 8.

Check that the alarm on the rectifier is valid, by performing


a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "rectifier 48V" equipment is "failed", the fault


is confirmed. Go to step 3.

If the state of the "rectifier 48V" equipment is "working", the


fault is not confirmed. Go to step 7.

On-site maintenance

Replace the faulty rectifier (Field Replaceable Unit). Refer to:

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting) for an S8000 BTS with rectifiers of a
six-rectifier type or for an S8000 BTS with rectifiers of a
seven-rectifier type

411-9001-084 (Nortel GSM BTS S8002 Troubleshooting) for


the S8002 BTS

Analyze the alarm.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

699

If the alarm persists, go to step 4.


If the alarm has disappeared, go to step 8.

Check the power supplies and solve the problem. Go to step 5.

Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 8.


If the alarm persists, go to step 6.

Check the state of the rectifier by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "rectifier 48V" equipment is still "failed", call


the manufacturer.

If the state of the "rectifier 48V" equipment is "working", go


to step 7.

Clear the alarm.

The procedure is complete.


--End--

2.12.114 RIPM-USER core (source: IPM BIST failed)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

RIPM-USER core

Source:

(15794208) IPM BIST failed

BTS model:

S8000 Indoor + S8000 Outdoor

FAULT ANALYSIS
This alarm indicates a BIST failed for the RIPM-USER.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
None.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

700

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

TROUBLESHOOTING
Procedure 10
Preliminary checks

Step

Action

Check that the alarm on the IPM-USER is valid by performing a


"Display hardware information" command on the IPM object.

ATTENTION
The "Display hardware information" command is not available if a
BTS inventory is already running on the btsSiteManager object.

Look at the result displayed in the "Session log" window.

If the state of the "IPM" equipment is "failed", the fault is


confirmed.

If the state of the "IPM" equipment is "working", the fault is


not confirmed. Go to step 4.

On-site maintenance using the OMC-R

Replace the RIPM-USER


See Nortel GSM BTS S8000/S8003 Troubleshooting
(411-9001-048).

Check the alarm state in the "Current Alarm list" window, and
make sure the alarm has disappeared.

Clear the alarm, if still present.

The procedure is complete.


--End--

2.12.115 RIPM-USER core (source: IPM temperature)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

RIPM-USER core

Source:

(15794211) Temperature

BTS model:

S8000 Indoor + S8000 Outdoor

FAULT ANALYSIS
This alarm indicates an excessively high temperature on an RIPM-USER.

REACTION OF THE SYSTEM


BSC defense
None.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

701

Impact on the service


None.

TROUBLESHOOTING
Procedure 11
Preliminary checks

Step

Action

Check that the alarm on the IPM-USER is valid by performing a


"Display hardware information" command on the IPM object.

ATTENTION
The "Display hardware information" command is not available if a
BTS inventory is already running on the btsSiteManager object.

Look at the result displayed in the "Session log" window.

If the state of the "IPM" equipment is "failed", the fault is


confirmed.

If the state of the "IPM" equipment is "working", the fault is


not confirmed. Go to step 4.

On-site maintenance using the OMC-R

Replace the RIPM-USER


See Nortel GSM BTS S8000/S8003 Troubleshooting
(411-9001-048).

Check the alarm state in the "Current Alarm list" window, and
make sure the alarm has disappeared.

Clear the alarm, if still present.

The procedure is complete.


--End--

2.12.116 RIPM-USER core (source: DAC unable to lock,


synchronization not possible)
Fault number 1067

Abis event reporting a hardware fault

Equipment:

RIPM-USER core

Source:

(15794224) DAC unable to lock, synchronization not possible

BTS model:

S8000 Indoor + S8000 Outdoor

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

702

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

FAULT ANALYSIS
The RIPM-USER generates a "Frequency saturation" event in case the
local oscillator cannot be frequency-locked, within its operational tuning
range.
The begin-of fault alarm indicates that the current value of the DAC
(Digital-to-Analog Converter) is not within a nominal range. The DAC
value is not within in this range for a time for that reaches the confirmation
threshold.
The end-of-fault alarm indicates that the current DAC value is within a
nominal range. The DAC value is within in this range for a time for that
reaches the confirmation threshold.
The causes for this alarm are:

The RIPM-USER local oscillator has experienced a large frequency


skew with age. It is no more able to lock to the BSC reference clock
within its nominal tuning range. This is the most probable cause.

The network reference frequency is in failure. This is the least probable


cause.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service

TROUBLESHOOTING
Procedure 12
Preliminary checks

Step

Action

Check that the alarm on the IPM-USER is valid by performing a


"Display hardware information" command on the IPM object.

ATTENTION
The "Display hardware information" command is not available if a
BTS inventory is already running on the btsSiteManager object.

Look at the result displayed in the "Session log" window.

If the state of the "IPM" equipment is "failed", the fault is


confirmed.

If the state of the "IPM" equipment is "working", the fault is


not confirmed. Go to step 4.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

703

On-site maintenance using the OMC-R

Replace the RIPM-USER.


See Nortel GSM BTS S8000/S8003 Troubleshooting
(411-9001-048).

Check the alarm state in the "Current Alarm list" window, and
make sure the alarm has disappeared.

Clear the alarm, if still present.

The procedure is complete.


--End--

2.12.117 RIPM-USER core (source: No link with passive)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

RIPM-USER core

Source:

(15794241) No link with passive

BTS model:

S8000 Indoor + S8000 Outdoor

FAULT ANALYSIS
This alarm indicates that there is no link between the active RIPM-USER
core and the passive RIPM-USER core.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
None.

TROUBLESHOOTING
Procedure 13
Preliminary checks

Step

Action

Check that the alarm on the IPM-USER is valid by performing a


"Display hardware information" command on the IPM object.

ATTENTION
The "Display hardware information" command is not available if a
BTS inventory is already running on the btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

704

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Look at the result displayed in the "Session log" window.

If the state of the "IPM" equipment is "failed", the fault is


confirmed.

If the state of the "IPM" equipment is "working", the fault is


not confirmed. Go to step 4.

On-site maintenance using the OMC-R

Replace the RIPM-USER.


See Nortel GSM BTS S8000/S8003 Troubleshooting
(411-9001-048).

Check the alarm state in the "Current Alarm list" window, and
make sure the alarm has disappeared.

Clear the alarm, if still present.

The procedure is complete.


--End--

2.12.118 Rx Filter (source: LNA fault)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

Rx Filter (LNA)

Source:

(7602177) LNA fault

BTS model:

S8000 Outdoor + S8000 Indoor + S8003

FAULT ANALYSIS
This alarm is detected by the RECAL board.
This alarm indicates a hardware problem on the low noise amplifier. The
related reception path (main or diversity) is not operational for the TRXs
using the faulty LNA. However, if the other path is still correct, these TRXs
run in a degraded mode.
REACTION OF THE SYSTEM
BSC defense
If there is no reception path, the BSC unconfigures the transceiver
Equipment objects corresponding to the faulty LNA. One or several
transceiverEquipment objects can be lost.
Impact on the service

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

705

CAUTION
Service reduction
The service is reduced.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 14.

Check the state of F-type converters by performing a "Display


hardware configuration" command on the btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

706

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Look at the result displayed in the "Session log" window.

If the state of the "converter F" equipment is "failed", go to


step 4.

If the state of the "converter F" equipment is "working", go to


step 3.

Check that the alarm on the combiner duplexer LNA is valid by


performing a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "LNA" equipment is "failed", the fault is


confirmed. Go to step 6.

If the state of the "LNA" equipment is "working", the fault is


not confirmed. Go to step 13.

On-site maintenance using the OMC-R

Look for alarms concerning the F-type converters and process


them.

If the alarm has disappeared, go to step 14.


If the alarm persists, go to step 5.

If the L1 (PA for the GIPS) circuit breaker is in the "O" position,
put it in the "I" position. Go to step 7.

If the operationalState of the bts object is "disabled" and its


availabilityStatus is "dependency", set the administrativeState of
the bts object to "locked", and set the administrativeState of the
associated transceiverEquipment objects to "locked".

Replace the RF-combiner (Field Replaceable Unit) associated


with the LNA-combiner. Refer to:

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting).

Check the cable between the LNA and the connection panel.

If it is correct, go to step 9.
If it is not correct, replace it (Shop Replaceable Unit).
If the alarm has disappeared, go to step 14.
If the alarm persists, go to step 9.

Replace the RECAL board (Field Replaceable Units). Refer to:

411-9001-048 (Nortel GSM BTS S8000/S8003


Troubleshooting).

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

707

If the alarm has disappeared, go to step 14.


If the alarm persists, go to step 10.
10

Check the cable between the connection panel and the RECAL
board.

If it is correct, go to step 11.


If it is not correct, replace it (Shop Replaceable Unit). Go to
step 11.

Additional checks

11

Check the alarm state in the "Current Alarm list" window.

12

If the alarm has disappeared, go to step 14.


If the alarm persists, go to step 12.

Check the state of the equipment by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "LNA" equipment is still "failed", call the


manufacturer.

If the state of the "LNA" equipment is "working", go to step


13.

13

Clear the alarm.

14

The procedure is complete.


--End--

2.12.119 SYNC boards (source: Major fault on SYNC)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

SYNC

Source:

(4325377) Major fault on SYNC

BTS model:

S8000 Outdoor + S8000 Indoor

FAULT ANALYSIS
The equipment number specified in the alarm identifies the faulty SYNC
board.

REACTION OF THE SYSTEM


BSC defense If there is a redundant board, there is no defense action.
If there is an alarm on both SYNC boards, the BSC unconfigures the bts
objects.
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

708

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

CAUTION
Service interruption
If there is a redundant board, the site is not lost. Otherwise, the
site is lost.

TROUBLESHOOTING
Step

Action

Preliminary checks

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel
GSM BSS Fault Clearing - Advanced Maintenance
Procedures) ).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 7.

Check that the alarm on the SYNC board is valid, by


performing a "Display hardware configuration" command on the
btsSiteManager object.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

709

Look at the result displayed in the "Session log" window.

If the state of the "SYNC" equipment is "failed", the fault is


confirmed. Go to step 3.

If the state of the "SYNC" equipment is "working", the fault is


not confirmed. Go to step 6.

On-site maintenance

Replace the faulty SYNC board (Field Replaceable Unit).


Refer to 411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting).

Additional checks

Check the alarm state in the "Current Alarm list" window.

If the alarm has disappeared, go to step 7.


If the alarm persists, go to step 5.

Check the state of the SYNC board by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "SYNC" equipment is still "failed", call the


manufacturer.

If the state of the "SYNC" equipment is "working", go to step


6.

Clear the alarm.

The procedure is complete.


--End--

2.12.120 Tx Filters (source: VSWR level 2)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

Tx Filter (VSWR)

Source:

(7536642) VSWR level 2

BTS model:

S8000 Outdoor + S8000 Indoor + S8003

FAULT ANALYSIS
This alarm indicates that an abnormal VSWR level has been detected at
the combiner output. The radio link is still operating.

REACTION OF THE SYSTEM


BSC defense
None.
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

710

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Impact on the service

None.

2.12.121 Tx Filters (source: VSWR level 3)


Fault number 1067

Abis event reporting a hardware fault

Equipment:

Tx Filter (VSWR)

Source:

(7536643) VSWR level 3

BTS model:

S8000 Outdoor + S8000 Indoor + S8003

FAULT ANALYSIS
This alarm indicates that the radio link has been interrupted in the
transmission path for one TRX using the corresponding equipment. This
TRX is no longer operational.
REACTION OF THE SYSTEM
BSC defense
The BSC unconfigures one transceiverEquipment object.
Impact on the service

CAUTION
Service reduction
The service is reduced.

TROUBLESHOOTING
Preliminary checks

Step

Action

Check the state of the site by performing a "Display all"


command on the btsSiteManager object.

If the operationalState of the btsSiteManager object is


"enabled", the site is operational. Go to step 2.

If the operationalState of the btsSiteManager object is


"disabled-dependency", the site is not operational.
If a fault number 1054 (loss of layer 2) has appeared,
refer to the fault number 1054 (see 411-9001-105 (Nortel

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.12 Fault number: 1067 (S8000, S8002, S8003, and S8006 BTS)

711

GSM BSS Fault Clearing - Advanced Maintenance


Procedures) ).
If not, look for an object whose state is "disabled-failed"
and process the problem in order that the btsSiteManager
object becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled-failed", the site is not operational. Do not process
the alarm and do not clear it. Look for other alarms and
process the problem in order that the btsSiteManager object
becomes "enabled".

If the operationalState of the btsSiteManager object is


"disabled", the site is not operational.
a. As long as the operationalState of the btsSiteManager
object is "disabled", do not process the alarm and do
not clear it. Wait for the state of the btsSiteManager
object to become "enabled", "disabled-dependency", or
"disabled-failed".
b. As soon as the site is operational (the operationalState of
the btsSiteManager object will be "enabled"), check if the
alarm persists.

If the alarm persists, go to step 2.

Otherwise, go to step 8.

Check that the alarm on the Tx Filter is valid, by performing


a "Display hardware configuration" command on the
btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "txFilter" equipment is "failed", the fault is


confirmed. Go to step 3.

If the state of the "txFilter" equipment is "working", the fault is


not confirmed. Go to step 7.

On-site maintenance

Check the cabling between the associated Tx Filter and antenna.

If it is correct, go to step 4.
If it is not correct, replace it (Shop Replaceable Unit). Go to
step 5.

If there are three alarms with source: level 2, and source:


level 3, replace the associated Tx Filter (Field Replaceable
Unit). Refer to 411-9001-048 (Nortel GSM BTS S8000/S8003
Troubleshooting). Go to step 5.

Additional checks

Check the alarm state in the "Current Alarm list" window.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

712

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

If the alarm has disappeared, go to step 8.


If the alarm persists, go to step 6.

Check the state of the Tx Filter by performing a "Display


hardware configuration" command on the btsSiteManager object.
Look at the result displayed in the "Session log" window.

If the state of the "txFilter" equipment is still "failed", call the


manufacturer.

If the state of the "txFilter" equipment is "working", go to step


7.

Clear the alarm.

The procedure is complete.


--End--

2.13 Fault number: 1070 (S8000, S8002, S8003, and S8006 BTS)
Fault number:
1070

TRX synchronization failure

Type

equipmentAlarm

This problem is associated with a PCM fault. See 411-9001-105 (Nortel


GSM BSS Fault Clearing - Advanced Maintenance Procedures)

2.14 Fault number: 1073 (S8000, S8002, S8003, and S8006 BTS)
Fault number:
1073

Attempt of download failure on a GSM entity

Type

communicationsAlarm

FAULT ANALYSIS
This notification, issued by the BSC, appears when the downloading of
a new software release has failed.

When the downloading is successful, the site or the DRX or DRX-ND3


requests a reset of the entity by the BSC (reception by the BSC of a
LOAD READY NACK, issued by the BTS). The fault number 1073 is
issued alone after reception of this LOAD READY NACK. The BTS is
operational.

When the downloading is not successful (error in a file), the


downloading stops and another downloading is performed
automatically. The downloading starts from scratch.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.14 Fault number: 1073 (S8000, S8002, S8003, and S8006 BTS)

713

Each time the downloading fails, the fault number 1073 is issued.
After four failed attempts (and four fault numbers 1073 issued), a
new downloading starts. If it fails, the fault number 1052 is issued
alone.
Table 24
Fault number 1073 sources
Source
No.

Source wording

Paragraph

No response to status request

Bad hardware reference or manufacturer ID

Reception Stop from SUP

No change to one of BOOT after reset

This entity is engaged in another


downloading

File access error

Repetitive errors (NACK, timeout, ... ) while


downloading a file

Wrong software reference on a non


downloadable TEI

No response to load message

2.14.1 Source 9:
No response to load
message (page 718)

10

Received LOAD INIT NACK

2.14.2 Source 10:


Received LOAD INIT
NACK (page 718)

11

Received LOAD DATA NACK

2.14.3 Source 11:


Received LOAD
DATA NACK (page
718)

12

Received LOAD END NACK

2.14.4 Source 12:


Received LOAD END
NACK (page 718)

13

Received LOAD READY NACK

14

CSM load container negative acknowledge


ment

15

File to download empty

16

File to download unavailable

17

Buffer allocation failure

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.14.5 Source 13:


Received LOAD
READY NACK
(page 718)

714

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Table 24
Fault number 1073 sources (contd.)
Source
No.

Source wording

Paragraph

18

Bad sending buffer size value

19

Failure during omu switchover

20

Bad TEI sent by BTS in the CSM software


update report message

21

CSM software update report with the cause


"unknown TEI"

22

CSM software update report with the cause


"equipment failure"

23

CSM software update report with the cause


"downloading failure"

24

CSM software update report with the cause


"not able to perform"

27

CSM software update report with the cause


"restart request"

29

CSM software update report with the cause


"message out of sequence"

32

CSM software update report with the cause


"downloading in progress"

33

Bad report sent by BTS in the CSM software


update report message

34

no BTS response on CSM software update


init/control message

35

nack received on the abort requested by


operator

36

bad report sent by BTS in the CSM software


update abort message

37

no BTS response on CSM software update


abort message

47

CSM downloading start nack with the cause


"equipment failure"

48

CSM downloading start nack with the cause


"downloading failure"

49

CSM downloading start nack with the cause


"message out of sequence"

50

CSM downloading start nack with the cause


"wrong soft ref"

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.14 Fault number: 1073 (S8000, S8002, S8003, and S8006 BTS)

Table 24
Fault number 1073 sources (contd.)
Source
No.

Source wording

Paragraph

51

CSM downloading start nack with the cause


"wrong config ref"

52

CSM downloading start nack with a bad


cause

53

no BTS response on CSM downloading start


message

55

CSM downloading end nack with the cause


"equipment failure"

56

CSM downloading end nack with the cause


"downloading failure"

57

CSM downloading end nack with the cause


"value out of range"

58

CSM downloading end nack with a bad


cause

59

no BTS response on CSM downloading end


message

60

CSM load init nack with the cause


"equipment failure"

61

CSM load init nack with the cause


"downloading failure"

62

CSM load init nack with the cause "message


out of sequence"

63

CSM load init nack with the cause "wrong file


ref"

64

CSM load init nack with the cause "window


size not allow"

65

CSM load init nack with the cause "data


format error"

66

CSM load init nack with a bad cause

67

no BTS response on CSM load init message

68

CSM load data nack with the cause


"equipment failure"

69

CSM load data nack with the cause


"downloading failure"

70

CSM load data nack with the cause


"message out of sequence"

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

715

716

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Table 24
Fault number 1073 sources (contd.)
Source
No.

Source wording

Paragraph

71

CSM load data nack with the cause "data


format error"

72

CSM load data nack with the cause "window


overflow"

73

CSM load data nack with the cause "data


inconsistency"

74

CSM load data nack with the cause "block


not received"

75

CSM load data nack with the cause "bad


block tag"

76

CSM load data nack with the cause


"checksum error"

77

CSM load data nack with a bad cause

78

unexpected CSM load data ack

79

no BTS response on CSM load data


message

80

CSM load end nack with the cause


"equipment failure"

81

CSM load end nack with the cause


"downloading failure"

82

CSM load end nack with the cause "value


out of range"

83

CSM load end nack with the cause


"message out of sequence"

84

CSM load end nack with the cause "data


format error"

85

CSM load end nack with the cause "wrong


file ref"

86

CSM load end nack with the cause "data


inconsistency"

87

CSM load end nack with the cause


checksum error

88

CSM load end nack with a bad cause

89

no BTS response on CSM load end


message

90

bad report sent by BTS during an internal


update

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.14 Fault number: 1073 (S8000, S8002, S8003, and S8006 BTS)

Table 24
Fault number 1073 sources (contd.)
Source
No.

Source wording

Paragraph

91

CSM load init nack with the cause "file


already open"

92

CSM load init nack with the cause "invalid


mode"

93

CSM load init nack with the cause "file


cannot be unloaded"

94

CSM load init nack with the cause "flash flag


cannot access"

95

CSM load data nack with the cause "file


cannot be unloaded"

96

CSM load data nack with the cause "flash


flag cannot access"

97

CSM load data nack with the cause "boot


cannot be unloaded"

98

CSM load data nack with the cause "data


decode error"

99

CSM load data nack with the cause "table


cannot access"

100

CSM load data nack with the cause "ram


mapping error"

101

CSM load data nack with the cause "flash


access error"

102

CSM load data nack with the cause "flash


ram error"

103

CSM load data nack with the cause "flash


erase error"

104

CSM load data nack with the cause "internal


abort"

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
None.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

717

718

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

2.14.1 Source 9: No response to load message


Fault number 1073 : Attempt of download failure on a GSM entity
Source:

(9) No response to load message

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

This problem is associated with a PCM fault. See 411-9001-105 (Nortel


GSM BSS Fault Clearing - Advanced Maintenance Procedures)

2.14.2 Source 10: Received LOAD INIT NACK


Fault number 1073 : Attempt of download failure on a GSM entity
Source:

(10) Received LOAD INIT NACK

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

This problem is associated with a PCM fault. See 411-9001-105 (Nortel


GSM BSS Fault Clearing - Advanced Maintenance Procedures)

2.14.3 Source 11: Received LOAD DATA NACK


Fault number 1073 : Attempt of download failure on a GSM entity
Source:

(11) Received LOAD DATA NACK

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

This problem is associated with a PCM fault. See 411-9001-105 (Nortel


GSM BSS Fault Clearing - Advanced Maintenance Procedures)

2.14.4 Source 12: Received LOAD END NACK


Fault number 1073 : Attempt of download failure on a GSM entity
Source:

(12) Received LOAD END NACK

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

This problem is associated with a PCM fault. See 411-9001-105 (Nortel


GSM BSS Fault Clearing - Advanced Maintenance Procedures)

2.14.5 Source 13: Received LOAD READY NACK


Fault number 1073 : Attempt of download failure on a GSM entity
Source:

(13) Received LOAD READY NACK

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

This problem is associated with a PCM fault. See 411-9001-105 (Nortel


GSM BSS Fault Clearing - Advanced Maintenance Procedures)

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.15 Fault number: 1077 (S8000, S8002, S8003, and S8006 BTS)

719

2.15 Fault number: 1077 (S8000, S8002, S8003, and S8006 BTS)
Fault number:
1077

Update of the activation status of a site

Type

Marking information

FAULT ANALYSIS
This notification is sent to indicate an up-to-date activation status of the
btsSiteManager object concerned, based on downloading results.
The soft activation status can be either 0 ("not ready") or 1 ("ready").
This notification is sent either at the end of a background downloading, or
after a state change of the btsSiteManager object concerned (failure or
unlock), as indicated in the Cause field of the notification:

either "End of background downloading"


or "Downloaded equipment state change"

The notification also contains the software downloading status, which can
be:

either 0 ("performed")
or 1 ("not performed"). If the software downloading status is set to 1
("not performed"), the failure cause is also given in the notification:

0 "CSM file download failure". This cause is sent when the BSC
cannot retrieve the file set to be downloaded. As a remedial action,
the operator has to check the files and restart the download.

1 "CSM equipment not able to perform such a procedure". This


cause is sent when the BTS supports centralized downloading
protocol, but not background downloading (such as the BTS S8000
CSWM). As a consequence, the background downloading is not
started.

2 "unreachable equipment". This cause is sent either when one


equipment (btsSiteManager or transceiverEquipment) is locked or
failed or which flash updating state is "Unknown TEI", or when the
BTS does not support CSM.

3 "background download to be restarted". This cause is sent when


one equipment (btsSiteManager or transceiverEquipment) has had
a major operational state change leading to a new background
download.

4 "already downloaded". This cause is sent when one soft is


asked to be downloaded again without any change on site. The

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

720

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

equipment flash updating state is "flash up-to-date, same soft in


RAM".

5 "abort by operator". This cause is sent after the operator has


performed the Abort action. Then the BackgroundActivate action is
forbidden, even if background downloading has been successfully
terminated before the Abort action.

REACTION OF THE SYSTEM


BSC defense
Depending on the activation status ("ready" or "not ready"), the BSC
authorizes or not the activation of the downloaded software.

Impact on the service


None.

TROUBLESHOOTING
No maintenance is required, except if a simultaneous failure of equipment
occurred. Look for alarms on the btsSiteManager object concerned.
Refer to the NRP on BTS Background Downloading (DS/BSS/APP/10) to
know more about the background downloading process (download and
activate operations) and the fallback procedure.

2.16 Fault number: 1080 (S8000, S8002, S8003, and S8006 BTS)
Fault number:
1080

Access fault

Type

equipmentAlarm

FAULT ANALYSIS
This fault number indicates a communication problem between the BSC
and the BTS. More precisely, there is an issue between the SPR and
Access software modules of the BSC (SPR defense on opening or closing
a link or dialog).
List of causes:

0 No response from Access for chnl cnx request


1 Nack from Access for chnl cnx request
2 No response from Access for chnl dcnx request
3 Nack from Access for chnl dcnx request
4 No response from Access for chnl switchover request
5 Nack from Access for chnl switchover request
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.18 Fault number: 1213 (S8000, S8002, S8003, and S8006 BTS)

721

6 No response from Access for OML open diag request


7 Nack from Access for OML open diag request
8 No response from Access for OML close diag request
9 Nack from Access for OML close diag request
10 No response from Access for RSL open diag request
11 Nack from Access for RSL open diag request
12 No response from Access for RSL close diag request
13 Nack from Access for RSL close diag request
14 No response from Access for GSL open diag request
15 Nack from Access for GSL open diag request
16 No response from Access for GSL close diag request
17 Nack from Access for GSL close diag request

REACTION OF THE SYSTEM


BSC defense
The BSC tries to use other LAPD channels to reach the BTS.
Impact on the service
TROUBLESHOOTING
If the BSC succeeds in using other LAPD channels, then no maintenance
action is required.
If the BSC fails, then other fault numbers are sent to the OMC-R.

2.17 Fault number: 1165 (S8000, S8002, S8003, and S8006 BTS)
Fault number
1165

At least one terrestrial circuit is HSCSD-blocked.

Type

equipmentAlarm

This problem is associated with a PCM fault. See 411-9001-105 (Nortel


GSM BSS Fault Clearing - Advanced Maintenance Procedures).

2.18 Fault number: 1213 (S8000, S8002, S8003, and S8006 BTS)

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

722

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Fault number:
1213

Secured loop unavailable

Type

equipmentAlarm

This problem is associated with a PCM fault. See 411-9001-105 (Nortel


GSM BSS Fault Clearing - Advanced Maintenance Procedures)

2.19 Fault number: 1214 (S8000, S8002, S8003, and S8006 BTS)
Fault number:
1214

Secured loop problem

Type

equipmentAlarm

This problem is associated with a PCM fault. See 411-9001-105 (Nortel


GSM BSS Fault Clearing - Advanced Maintenance Procedures)

2.20 Fault number: 1258 (S8000, S8002, S8003, and S8006 BTS)
Fault number:
1258

No BTS response on preprocessing configuration

Type

equipmentAlarm

FAULT ANALYSIS
This fault number indicates a non-response of a transceiverEquipment
object to an L1M request. The BTS issues this alarm after five
unsuccessful attempts to warn users that the data handled by the BSC
may not be consistent with the data actually received by the BTS.
In spite of this handling, the BSC continues its configuration attempts. The
situation must be reestablished.
The message loss, due to disruptions on the Abis link, is sufficient for
the creation of this notification, but insufficient to release the defense
mechanism of the transceiverEquipment object.
REACTION OF THE SYSTEM
BSC defense
None.
Impact on the service

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.20 Fault number: 1258 (S8000, S8002, S8003, and S8006 BTS)

723

CAUTION
Service interruption
The service is lost.

TROUBLESHOOTING
Step

Action

Check the time of the alarm appearance and note the different
commands performed at the OMC-R on the cell concerned and
on the neighboring cells, if any.

Check which parameters are concerned by the notification: those


of the cell or those of the neighboring cells.

Check if it is a startup or a change, in order to understand the


commands performed in the notification log.

Check the state of the bts, pcmCircuit, btsSiteManager and


transceiverEquipment objects.

Perform a "display dynamic data" on the transceiver object.

Ensure that the state of the parameter "allocationState" is


"available".
If the state of the parameter "allocationState" is not
"available", the BTS has not recognized or not received
the messages from the BSC.

Perform one of the following:

If the state of the parameter "rmpConfState" is "not


configured", the fault is confirmed. Go to step 6.

For the BSC 3000, call the manufacturer.

To create an adjacent cell on the bts object:

Select the bts object.

In the dialog box, select either the "adjacentCellReselection"


or "adjacentCellHandover" object.

Go to the "Objects" menu and select the "Create Child"


option. This opens a dialog box which allows the operator to
select various dependent objects.

The procedure is complete.


--End--

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

724

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

2.21 Fault number: 1259 (S8000, S8002, S8003, and S8006 BTS)
Fault number:
1259

Negative acknowledgement on preprocessing command

Type

equipmentAlarm

FAULT ANALYSIS
This alarm can be received on either a standard cell or on a neighboring
cell.

If the alarm is received on a neighboring cell, there are no longer any


handovers, as the neighboring cells are unknown.

If the alarm is received on a standard cell, the problem could have


occurred during the startup or during a change.

REACTION OF THE SYSTEM


BSC defense
None.
Impact on the service
If the alarm is received on a neighboring cell, calls are still possible.
Nevertheless, the calls cannot be moved on the neighboring cells (no
handover is possible). There will then be an increase in the rate of call
drops.

CAUTION
Service reduction
The geographical mobility of the mobile is reduced.
If the mobile is out of the geographical area of the cell, the
service is reduced.

TROUBLESHOOTING
If the alarm appears during a startup, a problem occurred in the BTS
configuration during installation.
If the alarm appears during a change, check the OMC-R commands
issued before the alarm appeared. Check the changes performed for the
neighboring cells.
If the microCellInstability and microCellStability parameters have a value,
ensure the value is "algo B". If it is not, modify it.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.22 Fault number: 1265 (S8000, S8002, S8003, and S8006 BTS)

725

2.22 Fault number: 1265 (S8000, S8002, S8003, and S8006 BTS)
Fault number:
1265

Blockage of radio channel(s) in busy state

Type

communicationsAlarm

FAULT ANALYSIS
This alarm indicates that channels were busy during a time period that was
higher than the surveillance period chosen by the operator.
The notification lists all the radio channels of the BTS that were busy
during the traffic surveillance, during the period chosen by the operator.
REACTION OF THE SYSTEM
BSC defense
None.
Impact on the service
None.
FAULT LOCATION
The notification indicates, for the concerned BTS, the busy channel(s).
TROUBLESHOOTING
Step

Action

Check the time of the fault number 1265 and identify the faulty
channel.

Check the call duration in comparison with the surveillance


period by checking the radResSupBusytimer parameter of the
bsc object.

If the call duration is equal or higher than the value of the


surveillance period, go to step 3.

If it is not the call duration that is concerned, but that is the


source of the fault number, call the manufacturer.

Increase the value of the surveillance period.

If the alarm persists, go to step 4.


If the alarm has disappeared, go to step 5.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

726

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Set the transceiver object to "locked", then to "unlocked".

If the alarm persists, call the manufacturer.


If the alarm has disappeared, go to step 5.

The procedure is complete.


--End--

2.23 Fault number: 1266 (S8000, S8002, S8003, and S8006 BTS)
Fault number:
1266

Blockage of radio channel(s) in free state

Type

communicationsAlarm

FAULT ANALYSIS
When the radResSupervision parameter is "true", a notification with the
1266 fault number is sent periodically to the OMC-R.
The notification indicates all the BTS radio channels that have been
continuously free for the previous notification.
This period is determined by the radResSupFreetimer parameter of the
bsc object. This parameter sets the maximum duration of non utilization
for a radio channel.
REACTION OF THE SYSTEM
BSC defense
None.
Impact on the service

CAUTION
Service reduction
The service is reduced.

FAULT LOCATION
The notification indicates, for the concerned BTS, the free channel(s).
TROUBLESHOOTING

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.24 Fault number: 1268 (S8000, S8002, S8003, and S8006 BTS)

727

Step

Action

Check the time of the fault number 1266 and identify the faulty
channel.

Analyze the traffic on the network by checking the rate of


call drop (TCH number busy in comparison to cell resource
number). Refer to Nortel GSM BSS Performance Management
- Observation Counters Dictionary (411-9001-125) for the
observation counters.

If the traffic is low, the fault number 1266 is normal.


If the traffic is high (almost equal to the TCH number in the
cell), the faulty channels are not used. Call the manufacturer.

Analyze the traffic on the network by checking the rate of


SDCCH allocation failures.
Check the synthetic counter C8706 (cellSdcchResourceFailure
Ratio).

If the counter value is low (SDCCH blocking is not observed),


the fault number 1266 is normal.

If the counter value is high (SDCCH blocking is observed),


and still fault number 1266 is observed, this requires further
investigation. Call the manufacturer.

--End--

2.24 Fault number: 1268 (S8000, S8002, S8003, and S8006 BTS)
Fault number:
1268

NO RESPONSE TO A SACCH FILLING (SYS 5, 6, 5bis, 5ter


or meas_info)

Type

communicationsAlarm

FAULT ANALYSIS
This alarm indicates that the BTS has not answered nine successive
acknowledgment requests SACCH filling sent by the BSC. As long
as the BSC has not received response, it repeats the procedure of
acknowledgment request.
REACTION OF THE SYSTEM
BSC defense

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

728

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

None.
Impact on the service

CAUTION
Service reduction
The channels supported by the faulty TRXs are not available
for calls.
The service is reduced.

TROUBLESHOOTING
Step

Action

Look for the TRX supported the TDMA quoted in the alarm by
performing a "Display all" command on the transceiverEquipment
objects.

Check the state of the channels associated with the TDMA.

If all the channels are not available, perform the return to


service procedure.

Otherwise, stop the maintenance procedure: the state of the


system is normal.

Set the transceiverEquipment object associated with the TDMA


to "locked" then to "unlocked".

Wait for the state of the transceiver object to become "enabled".

Check the state of the channels associated with the TDMA.

The procedure is complete.


--End--

2.25 Fault number: 1500 (S8000, S8002, S8003, and S8006 BTS)
Fault number:
1500

Measurement received on an unknown frequency of


neighboring cell

Type

communicationsAlarm

FAULT ANALYSIS
This alarm indicates that a measurement has been received on an
unknown frequency of a neighboring cell in GSM 900 or GSM 1800 mode.
The message is sent at the end of the communication.
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.26 Fault number: 1505 (S8000, S8002, S8003, and S8006 BTS)

729

2.26 Fault number: 1505 (S8000, S8002, S8003, and S8006 BTS)
Fault number:
1505

No response to BCCH info (SYS 1, 2, 3, 4, 2 bis, 7, 8, 2 ter,


13)

Type

communicationsAlarm

FAULT ANALYSIS
This alarm indicates that the BTS has not answered nine successive
acknowledgment requests BCCH INFO sent by the BSC. As long as
the BSC has not received any response, it repeats the procedure of
acknowledgment request.
REACTION OF THE SYSTEM
BSC defense
None.
Impact on the service

CAUTION
Service interruption
The service is lost.

TROUBLESHOOTING
Step

Action

If the alarm appears during the downloading of the site and the
TRXs, do not take this alarm into account. Otherwise, go to step
2.

Set the btsSiteManager concerned to "locked" then "unlocked".

If the alarm persists, go to call the manufacturer.


If the alarm has disappeared, go to step 3.

The procedure is complete.


--End--

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

730

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

2.27 Fault number: 1506 (S8000, S8002, S8003, S8006 BTS)


Fault number:
1506

No distribution available for a cell

Type

communicationsAlarm

FAULT ANALYSIS
This warning indicates that no distribution is available for the cell
concerned.
To help network monitoring, the distribution at TDMA level of some
measurements done on radio interface is provided for the TRX of given
cells and on a periodic time frame. Distributions are collected by the BSC
and aggregated in a file that is uploaded by the OMC-R.
The available distributions are the following:

power control steps


RxLev and RxQual
FER uplink
Timing advance
SNR
RxLev rescaled to Pmax
TEPMOS
FER downlink
Downlink voice quality indicator

List of causes:

0 "No stop_distribution_ack received":


If for all TRXs of a cell the BTS has sent no stop_distribution_ack
message to the BSC, then the BSC emits a notification
1506 no distribution available for a cell with the cause "No
stop_distribution_ack received", even if all TRXs are locked.

1 "No measurements available":


If for all TRXs of a cell the BTS has sent no measurements at all to the
BSC, then the BSC emits a notification 1506 no distribution available
for a cell with the cause "No measurements available", even if all
TRXs are locked.

REACTION OF THE SYSTEM


BSC defense
Global System for Mobile Communications (GSM)
Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.28 Fault number: 1508 (S8000, S8002, S8003, S8006 BTS)

731

None.
Impact on the service
None.
TROUBLESHOOTING
No maintenance action is required.

2.28 Fault number: 1508 (S8000, S8002, S8003, S8006 BTS)


Fault number:
1508

Data service impact (SYS 13 size exceeded)

Type

Quality of Service Alarm

FAULT ANALYSIS
When the operator configures maximum hopping frequencies (64
frequencies) and activates GPRS or EGPRS in a cell, then "System
Information 13 rest octet" size exceeds 21 octets. As a result the "System
Information 13 rest octet" field is truncated and this begin-of-fault alarm
is sent.
64 frequencies is the maximum number granted by the OMC-R (semantic
control). But operators must also take into account Engineering
recommendations given in BSS Parameters User Guide (BPUG).
The end-of-fault alarm is sent after the "System Information 13 rest octet"
field size has become equal to 21 octets or less.

REACTION OF THE SYSTEM


BSC defense
None.

Impact on the service


CAUTION
Service interruption
There is a partial or full impact on data service (whereas CS
traffic is still maintained).
The information relative to data services on impacted cell(s) are
not fully sent to the BTS.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

732

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

TROUBLESHOOTING
Refer to BSS Parameter User Guide (BPUG PE/DCL/DD/0036) to
configure the cell (cellAllocation and mobileAllocation parameters for the
bts object) in order to respect Engineering recommendations (maximum
hopping frequency number) and to have the "System Information 13 rest
octet" field size equal to 21 octets or less.
Normally, the maximum number of frequencies that can be set up with
cellAllocation parameter is 64 per frequency band. However, due to SI13
size constraints, when GPRS or EDGE is activated in the cell and there is
at least one hopping data TDMA, the limitation becomes a maximum of 49
- n frequencies.
where n is the number of non-hopping frequencies in the cell.

2.29 Fault number: 30034 (S8000, S8002, S8003, S8006 BTS)


Fault number 30034: Background downloaded action is aborted
Source:

30315 "BSC restart occurred"

Source:

30316 "Core process is nullex"

BTS model:

S8000 Outdoor + S8000 Indoor + S8002 + S8003


+ S8006

FAULT ANALYSIS
This warning is sent to indicate that a background downloading has
aborted.
When the SPR application (a task located on the TMU module of the BSC
3000) disappears, all background downloading contexts managed by it are
lost and cannot be recovered, as they are stored in volatile memory.
To make information in the whole system consistent, the matching
contexts managed by the ADM (task located on OMU) and OMC-R
must also be released. For that purpose, the event 30034 is sent by the
OMC-R signaling SPR loss and then all ongoing background downloading
procedures are aborted.
This can happen in two different situations:

at BSC reset, the warning 30034 source 30315 "BSC restart occurred"
is sent by the OMC-R and contains an empty list of sites managed by
the BSC

when the SPR becomes "nullex": the warning 30034, source 30316
"Core process is nullex" is sent by the OMC-R and contains the list of
sites managed by the instance of SPR application that has been killed

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.29 Fault number: 30034 (S8000, S8002, S8003, S8006 BTS)

733

REACTION OF THE SYSTEM


BSC defense
On receiving the warning 30034, both the ADM and the OMC-R will clear
the contexts associated with each site found in the list, if such a context
exists. If not, nothing has to be done for the site. The procedure is over,
and all contexts are consistent. No additional dialogue is necessary
between OMC-R and BSC.
Depending on the point that the SPR disappeared, the BTS flash may:

contain Vn software (if the download could not begin at all)


be invalidated (if download was begun but not completed)
contain Vn+1 software (if download has been completed)

As Vn is still stored in the SoftRef_BDA field of the BSC MIB, the BTS will
then be started in the Vn version, with potential offline download of Vn
software in the last 2 cases above.

Impact on the service


None.

TROUBLESHOOTING
The command bckgDownload must be re-executed. In the case that only
one software is requested to be downloaded again (without any change on
the site), the download will be accepted but in the notification 1077, the
status for this software will be "Not Performed" with the cause "Already
downloaded".
In case of abort of a bckgDownload with immediate activate, the BDE and
BDA databases will be on Vn+1 whereas the BTS will remain running in
Vn.
To re-align databases, the operator can:

lock/unlock the site, in such a case, this will lead to a realignment to


Vn+1 (that is, a "forced" upgrade)

reinitiate a background download of Vn with or without immediate


activate; in this case an off-line download of Vn will be necessary due
to the previous flash invalidation

manually reset database to Vn by a normal return-to-previous action

Since the flash has been overwritten, a future reset of BTS requiring flash
to restart will induce an off-line download of the running software version.

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

734

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Refer to the NRP on BTS Background Downloading (DS/BSS/APP/10) to


know more about the background downloading process (download and
activate operations) and the fallback procedure.

2.30 Applicability of the fault numbers to the BTS type


This paragraph contains the list of all the BTS fault numbers. For each
fault, it indicates the BTSs to which the fault applies. Each fault number
is described in a technical document, specific to the BTS. Refer to the
following technical documents to know more about the fault numbers, for
each BTS:

Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing


(411-9001-103)

Nortel GSM BTS S2000H/S2000L/e-cell Fault Clearing (411-9001-104)


Nortel GSM BTS S12000 Fault Clearing (411-9001-143)
Nortel GSM BTS 6000 and 18000 Fault Clearing (411-9001-161)
Nortel GSM BTS 9000 Fault Clearing (411-9001-214)

Table 25
Applicability of the fault numbers to the BTS type
S8000,
S8002,
S8003,
S8006

S2000H/L

e-cell

S12000

BTS 18000

BTS 6000

BTS 9000

411-9001103

411-9001104

411-9001104

411-9001143

411-9001161

411-9001161

411-9001214

1051

1052

1053

1054

1055

1056

1058

1059

1060

1061

1063

1064

1065

1067

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

2.30 Applicability of the fault numbers to the BTS type

735

Table 25
Applicability of the fault numbers to the BTS type (contd.)
S8000,
S8002,
S8003,
S8006

S2000H/L

e-cell

S12000

BTS 18000

BTS 6000

BTS 9000

411-9001103

411-9001104

411-9001104

411-9001143

411-9001161

411-9001161

411-9001214

1070

1073

1077

1078
1080

1258

1259

1265

1266

1268

1500

1505

1506

1507
1508

30034

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

736

Chapter 2 S8000, S8002, S8003, and S8006 BTS fault numbers

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

737

Index
S
S800 Indoor
1060 Abis event reporting a transient
default
Source (15728659) No response
to DHCP requests for 15
minutes: IPM 371
S800 Outdoor
1060 Abis event reporting a transient
default
Source (15728659) No response
to DHCP requests for 15
minutes: IPM 371
Source (15794191) Restart after
TML commissioning: RIPM 379
S8000
1080 Access fault 720
S8000 Indoor
1052 GSM entity downloading failure
Source (01) Bad hardware
reference of manufacturer ID 43
Source (03) No change to one of
BOOT states after reset 48
Source (04) This entity is engaged
in another downloading 52
Source (05) Software not
compatible with hardware 54
Source (06) File access error 58
Source (07) Repetitive errors
(NACK, timeout, ...) while
downloading a file 61
Source (08) Wrong software
reference on a non
downloadable TEI 52
Source (14) Received CSM LOAD
CONTAINER NAK 64

Source (16) File to download


unavailable 68
1055 Abis negative acknowledgement indication
Source (02) Equipment unable to
perform such test 285
Source (03) Equipment unable to
perform such configuration 286
Source (05) Cell parameters
inconsistency 288
Source (10) Unknown Abis PCM 293
Source (23) Too many signaling
timeslots 297
Source (25) Out of sequence
message 298
Source (34) The BTS has not
acknowledged the power
consign request 302
Source (43) Maximum number of
joker TS 309
Source (6) Data inconsistency 290
Source (63) Dynamic Abis feature
not supported 316
Source (64) Inconsistent number
of joker DS0 317
Source (65) Exceeded DL joker
DS0 pool number 319
Source (7) Value out of range 291
Source (8) TEI not present 292
1060 Abis event reporting a transient
default
Source (12582924) Frequency
collision on FH bus: eDRX 359
Source (12582935) FACCH
congestion: eDRX 360
Source (12583171) Restart
requested by the BCF: eDRX 360

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

738

Source (12583175) Restart due to


hardware watchdog: eDRX 361
Source (12583176) Restart due to
double bus fault: eDRX 362
Source (12583186) BCCH config
dump: eDRX 362
Source (12583202) SACCH config
dump: eDRX 363
Source (12583218) L1M config
dump: eDRX 363
Source (12583219) RSL anomaly:
eDRX 363
Source (12779522) Unknown
message: CMCF 355
Source (12779556) Restart
requested by the active board:
CMCF phase 1 356
Source (12779558) Restart due
to hardware watchdog: CMCF
phase 1 357
Source (12779559) Restart due to
double bus fault: CMCF phase
1 357
Source (12779560) Reset for new
Lapd parameters: CMCF Ph1 357
Source (12779571) Board reset
asked by OMC: CMCF phase 1 356
Source (12845041) ABIS PCM
statistics: CMCF PH1 358
Source (12845058) Unknown
message: CMCF phase 2 355
Source (12845092) Restart
requested by the active board:
CMCF phase 2 356
Source (12845094) Restart due
to hardware watchdog: CMCF
phase 2 357
Source (12845095) Restart due to
double bus fault: CMCF phase
2 357
Source (12845096) Reset for new
Lapd parameters CMCF Ph2 357
Source (12845107) Board reset
asked by OMC: CMCF phase 2 356
Source (12910577) ABIS PCM
statistics: CMCF PH2 358
Source (12976140) Frequency
collision on FH bus: DRX-ND3 359
Source (12976151) FACCH
congestion: DRX ND3 360

Source (12976387) Restart


requested by the BCF:
DRX-ND3 360
Source (12976389) Restart
due to hardware watchdog:
DRX_ND3 361
Source (12976390) Restart due to
double bus fault: DRX_ND3 362
Source (12976402) BCCH config
dump: DRX_ND3 362
Source (12976418) SACCH config
dump: DRX_ND3 363
Source (12976434) L1M config
dump: DRX_ND3 363
Source (12976435) RSL anomaly:
DRX_ND3 363
Source (15204364) Frequency
collision on FH bus: eDRX2 359
Source (15204375) FACCH
congestion: eDRX2 360
Source (15204611) Restart
requested by the BCF: eDRX2 360
Source (15204615) Restart
due to hardware watchdog:
DRX_ND3 361
Source (15204615) Restart due to
hardware watchdog: eDRX2 361
Source (15204616) Restart due to
double bus fault: eDRX2 362
Source (15204626) BCCH config
dump: eDRX2 362
Source (15204642) SACCH config
dump: eDRX2 363
Source (15204658) L1M config
dump: eDRX2 363
Source (15204659) RSL anomaly:
eDRX2 363
Source (15728641) Restart due to
power on: IPM 364
Source (15728642) Restart due to
reset by button: IPM 364
Source (15728643) Restart due to
software upgrade: IPM 365
Source (15728644) Restart due to
hardware watchdog: IPM 365
Source (15728647) IBOS
authentication has failed: IPM 366
Source (15728648) No TCP
connection can be set up with
IGM: IPM 366

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

739

Source (15728649) Reset


requested by IGM with no
Ethernet switch reset: IPM 367
Source (15728650) Reset
requested by IGM with Ethernet
switch reset: IPM 367
Source (15728651) Reset
requested by IBOS with BIST
execution and Ethernet switch
reset: IPM 368
Source (15728652) Reset
requested by IBOS with no
BIST execution and Ethernet
switch reset: IPM 368
Source (15728653) Reset
requested by IBOS with BIST
execution and no Ethernet
switch reset: IPM 369
Source (15728654) Reset
requested by IBOS with no
BIST execution nor Ethernet
switch reset: IPM 370
Source (15728655) Restart after
TML commissioning: IPM 370
Source (15728656) Connection
with IGM has been lost (no
status received for 7 keep-alive
periods): IPM 371
Source (15728660) No response
to DNS requests for 15 minutes:
IPM 372
Source (15728673) Debug 372
Source (15728674) Soft: IPM 373
Source (15794177) Restart due to
power on: RIPM 373
Source (15794178) Restart due to
reset by button: RIPM 374
Source (15794179) Restart due to
software upgrade: RIPM 374
Source (15794180) Restart due to
hardware watchdog: RIPM 375
Source (15794183) IBOS
authentication has failed: RIPM 375
Source (15794184) No TCP
connection can be set up with
IGM: RIPM 376
Source (15794185) Reset
requested by IGM with no
Ethernet switch reset: RIPM 376

Source (15794186) Reset


requested by IGM with Ethernet
switch reset: RIPM 377
Source (15794187) Reset
requested by IBOS with BIST
execution and Ethernet switch
reset: RIPM 377
Source (15794188) Reset
requested by IBOS with no
BIST execution and Ethernet
switch reset: RIPM 378
Source (15794189) Reset
requested by IBOS with BIST
execution and no Ethernet
switch reset: RIPM 378
Source (15794190) Reset
requested by IBOS with no
BIST execution nor Ethernet
switch reset: RIPM 379
Source (15794191) Restart after
TML commissioning: RIPM 379
Source (15794192) Connection
with IGM has been lost (no
status received for 7 keep-alive
periods): RIPM 380
Source (15794193) Reset
requested by active with BIST
execution: RIPM 383
Source (15794194) Reset
requested by active with no
BIST execution: RIPM 383
Source (15794195) No response
to DHCP requests for 15
minutes: RIPM 380
Source (15794196) No response
to DNS requests for 15 minutes:
RIPM 381
Source (15794209) Debug: RIPM 381
Source (15794210) Soft: RIPM 382
Source (15859969) Not enough
synchronization packets have
been received 636
Source (4259878) Restart due to
hardware watchdog: CSWM 358
Source (4259879) Restart due to
double bus fault: CSWM 359
Source (7536642) VSWR level 2:
TX Filter 384

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

740

Source (8388610) Cavity parked


after tuning fault (min not found):
cavity 352
Source (8388612) Nack answer
from cavity: cavity 354
Source (8388613) Cavity parked
after tuning fault (power too
low): cavity 354
Source (8388614) Cavity parked
after tuning fault (tuning
detector): cavity 355
Source (9437196) Frequency
collision on FH bus: DRX 359
Source (9437207) FACCH
congestion: DRX 360
Source (9437443) Restart
requested by the BCF: DRX 360
Source (9437447) Restart due to
hardware watchdog: DRX 361
Source (9437448) Restart due to
double bus fault: DRX 362
Source (9437458) BCCH config
dump: DRX 362
Source (9437474) SACCH config
dump: DRX 363
Source (9437490) L1M config
dump: DRX 363
Source (9437491) RSL anomaly:
DRX 363
Source (9502722) Unknown
message: CMCF 355
Source (9502756) Restart
requested by the active board:
CMCF 356
Source (9502758) Restart due to
hardware watchdog: CMCF 357
Source (9502759) Restart due to
double bus fault: CMCF 357
Source (9502760) Reset for new
Lapd parameters: CMCF 357
Source (9502771) Board reset
asked by OMC: CMCF 356
Source (9568241) ABIS PCM
statistics: CMCF 358
1063 TRX allocation for a TDMA 386
1067 Abis event reporting a
hardware fault 387
471
DRX 591

Source (12582913) RX fault:


eDRX 585
Source (12582918) BBFILTER
ASIC fault: eDRX 576
Source (12582921) Self test failed:
eDRX 609
Source (12582922) Major fault on
TX: eDRX 597
Source (12582934) DRX link:
eDRX 591
Source (12582939) PA config.
exceeded: DRX-ND3 573
Source (12582944) The TX has
not ack the power consign
request: eDRX 580
Source (12582945) PA DRX
control loop fault: eDRX 602
Source (12582946) DRX reset by
BCF after message non ack.:
eDRX 602
Source (12582947) DRX link NOK
after reset requested by BSC:
eDRX 596
Source (12583184) BCCH first
config failed: eDRX 589
Source (12583185) BCCH second
config failed: eDRX 590
Source (12583200) SACCH first
config failed: eDRX 607
Source (12583201) SACCH
second config failed: eDRX 608
Source (12583216) L1M first
config failed: eDRX 589
Source (12583217) L1M second
config failed: eDRX 597
Source (12648447) TRX not
anymore configured: eDRX 613
Source (12648449 ) Hardware:
ePA 652
Source (12648450) DRX and PA
connection: ePA 658
Source (12648451) High temp:
ePA 663
Source (12648452) High current:
ePA 667
Source (12648454) PA_PSDW:
ePA 671
Source (12713985) Hardware:
(H)(e)PA 652

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

741

Source (12713986) DRX and PA


connection: HePA 658
Source (12713987) High temp:
HePA 663
Source (12713988) High current:
HePA 667
Source (12713990) PA_PSDW:
HePA 671
Source (12779529) MCF_MCF:
CMCF phase 1 507
Source (12779538) CMCF ACT
DUPLEX INHIBITED: CMCF
phase 1 512
Source (12779539) CMCF ACT
ICST: CMCF phase 1 515
Source (12779540) Duplex
inhibited: feature not supported
on CMCF phase 1: CMCF
phase 1 517
Source (12845050) Slave
downloading error: CMCF
phase 1 510
Source (12845065) MCF_MCF:
CMCF phase 2 507
Source (12845074) CMCF ACT
DUPLEX INHIBITED: CMCF
phase 2 512
Source (12845075) CMCF ACT
ICST: CMCF phase 2 515
Source (12910586) Slave
downloading error: CMCF
phase 2 510
Source (12976129) RX fault:
DRX-ND3 585
Source (12976134) BBFILTER
ASIC fault: DRX-ND3 576
Source (12976137) Self test failed:
DRX-ND3 609
Source (12976138) Major fault on
TX: DRX-ND3 597
Source (12976150) DRX link:
DRX-ND3 591
Source (12976158) Abis satellite
not supported DRX ND3:
DRX-ND3 569
Source (12976160) The TX has
not ack the power consign
request: DRX-ND3 580
Source (12976161) PA DRX
control loop fault: DRX-ND3 602

Source (12976162) DRX reset by


BCF after message non ack.:
DRX-ND3 602
Source (12976163) DRX link NOK
after reset requested by BSC:
DRX-ND3 596
Source (12976400) BCCH first
config failed: DRX-ND3 589
Source (12976401) BCCH second
config failed: DRX-ND3 590
Source (12976416) SACCH first
config failed: DRX-ND3 607
Source (12976417) SACCH
second config failed: DRX-ND3 608
Source (12976432) L1M first
config failed: DRX-ND3 589
Source (12976433) L1M second
config failed: DRX-ND3 597
Source (13041663) TRX not
anymore configured: DRX-ND3 613
Source (15204361) Self test failed:
eDRX2 609
Source (15204362) Major fault on
TX: eDRX2 597
Source (15204374) DRX link:
eDRX2 591
Source (15204385) PA DRX
control loop fault: eDRX2 602
Source (15204386) DRX reset by
BCF after message non ack.:
eDRX2 602
Source (15204387) DRX link NOK
after reset requested by BSC:
eDRX2 596
Source (15204624) BCCH first
config failed: eDRX2 589
Source (15204625) BCCH second
config failed: eDRX2 590
Source (15204640) SACCH first
config failed: eDRX2 607
Source (15204641) SACCH
second config failed: eDRX2 608
Source (15204656) L1M first
config failed: eDRX2 589
Source (15204657) L1M second
config failed: eDRX2 597
Source (15269887) TRX not
anymore configured: eDRX2 613

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

742

Source (15663140) Only one IBOS


commissioned at IPM: IPM
commissioning 637
Source (15663141) DNS
resolution has failed for at least
one IBOS: IPM commissioning 638
Source (15728672) BIST failed:
IPM 639
Source (15728675) Temperature:
IPM 640
Source (15728688) DAC unable
to lock, synchronization not
possible: IPM 641
Source (15794208) BIST failed:
RIPM 699
Source (15794211) Temperature:
IPM 700
Source (15794224) DAC unable
to lock, synchronization not
possible: IPM 701
Source (15794241) No link with
passive: RIPM 703
Source (15859968) Unable to
lock on IP synchronization: IP
synchro 634
Source (3342340) SYNO clock
not locked on the network: BTS
synchronization 441
Source (3342341) Synchro not
locked because OCVXO is KO:
BTS synchronization 448
Source (3342343) GPS
synchronization unavailable:
BTS synchronization 451
Source (3342344) Loss of
GPS synchronization: BTS
synchronization 456
Source (3342345) Lack of GPS
synchronization accuracy: BTS
synchronization 461
Source (3342346) Master
synchronization unavailable:
BTS synchronization 466
Source (3342348) Loss of master
SY: BTS sunchronization 475
Source (3735553) Alarm: Not
protected alarm 646
Source (4259849) Fault on
active-passive CSWM link
or passive CSWM: CSWM 544

Source (4325370) Slave


downloading error: CSWM 547
Source (4325377) Major fault on
SYNC: SYNC 707
Source (4390913) Major fault:
ALCO 416
Source (4456453) Channel_HSCX: DSC 618
Source (4521985) Major fault:
PCMI 652
Source (4587521) Major fault on
GTW: GTW 628
Source (5242881) AC fault:
Rectifier 48V 682
Source (5242882) DC fault:
Rectifier 48V 686
Source (5242883) Over
temperature: Rectifier 48V 688
Source (5242884) External battery
level 1: Rectifier 48V 691
Source (5242885) PCU protective:
Rectifier 48V 693
Source (5242886) Battery on
discharges: Rectifier 48V 697
Source (5308417) Volt: Converter
F 624
Source (5373953) Volt: Converter
BCF 435
Source (5570561) LNA fault:
Combiner duplexer LNA or
combiner H2 LNA 520
Source (5636097) VSWR level
1: Combiner duplexer vswr or
combiner h2 vswr 524
Source (5636098) VSWR level
2: Combiner duplexer vswr or
combiner h2 vswr 524
Source (5636099) VSWR level
3: Combiner duplexer vswr or
combiner h2 vswr 525
Source (5898241) Door contact
detection: Door contact 479
Source (6225921) Cabinet fan
fault: Cabinet fan 621
Source (6291457) BCF cabinet
door contact detection: BCF
Cabinet door 429
Source (6356993) BCF cabinet fan
fault: BCF Cabinet fan 433
Source (6488065) PCM: PCM 652

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

743

Source (6815745) Hardware: PA 652


Source (6815746) DRX and PA
connection: PA 658
Source (6815747) High temp: PA 663
Source (6815748) High current:
PA 667
Source (6815750) PA_PSDW: PA 671
Source (6815751) VSWR fault
detected by PA: PA 675
Source (6881281) Software
detection: DRX main reception
chain 565
Source (6881281) Software
detection: DRX-ND3 main
reception chain 565
Source (6946817) Software
detection: DRX diversity
reception chain 560
Source (6946817) Software
detection: DRX-ND3 diversity
reception chain 560
Source (7274497) External alarm 621
Source (7405569) LNA fault:
Combiner h4 lna (LNA) 528
Source (7471105) VSWR level:
Combiner h4 vswr (VSWR) 532
Source (7471106) VSWR level 2:
Combiner h4 vswr (VSWR) 534
Source (7471107) VSWR level 3:
Combiner h4 vswr (VSWR) 536
Source (7536643) VSWR level 3:
Txfilter (VSWR) 710
Source (8323073) Power supply:
Cavity combiner 496
Source (8323074) Tuning detector
fault: Cavity combiner 498
Source (8323076) Link NOK:
Cavity combiner 500
Source (8388609) Cavity out of
service: Cavity 483
Source (8388610) Cavity parked
after tuning fault (min not found):
Cavity 485
Source (8388611) Loss of cavity
initialization: Cavity 487
Source (8388612) Nack answer
from cavity: Cavity 489
Source (8388613) Cavity parked
after tuning fault (power too
low): Cavity 490

Source (8388614) Cavity parked


after tuning fault (tuning detector
problems): Cavity 492
Source (8388615) Internal
software problem :Cavity 494
Source (9437185) RX fault: DRX 585
Source (9437190) BBFILTER
ASIC fault: DRX 576
Source (9437193) Self test failed:
DRX 609
Source (9437194) Major fault on
TX: DRX 597
Source (9437211) PA config.
exceeded: DRX 573
Source (9437212) HePA not
supported: DRX 570
Source (9437214) Abis satellite
not supported DRX: DRX 569
Source (9437216) The TX has not
ack the power consign request:
DRX 580
Source (9437217) PA DRX control
loop fault: DRX 602
Source (9437218) DRX reset by
BCF after message non ack.:
DRX 602
Source (9437219) DRX link NOK
after reset requested by BSC:
DRX 596
Source (9437456) BCCH first
config failed: DRX 589
Source (9437457) BCCH second
config failed: DRX 590
Source (9437472) SACCH first
config failed: DRX 607
Source (9437473) SACCH second
config failed: DRX 608
Source (9437488) L1M first config
failed: DRX 589
Source (9437489) L1M second
config failed: DRX 597
Source (9502719) TRX not
anymore configured: DRX 613
Source (9502729) MCF_MCF:
CMCF 507
Source (9568250) Slave
downloading error: CMCF 510
Source (9568257) Major fault:
CPCMI 541

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

744

Source (9633786) Slave


downloading error: CPCMI 541
Source (9633793) Major: RECAL 676
Source (9699322) Slave
downloading error: RECAL 679
Source (9699329) Over current:
Rx splitter M 649
Source (9764865) Over current:
Rx splitter D 646
Source 4456449) Major fault:
DSC 616
Source 7602177) LNA fault: Rx
Filter (LNA) 704
1067 Abis event reporting a transient
default
Source (7536642) VSWR level 2:
Tx filter (VSWR) 709
1070 TRX synchronization failure 712
1073 Attempt of download failure on
a GSM entity 712
Source (09) No response to load
message 718
Source (10) Received LOAD INIT
NACK 718
Source (11) Received LOAD DATA
NACK 718
Source (12) Received LOAD END
NACK 718
Source (13) Received LOAD
READY NACK 718
1077 Update of the activation status
of a site 719
1213 Secured loop unavailable 721
1214 Secured loop problem 722
1258 No BTS response on
preprocessing configuration 722
1259 Negative acknowledgement on
preprocessing command 724
1265 Blockage of radio channel(s) in
busy state 725
1266 Blockage of radio channel(s) in
free state 726
1268 NO RESPONSE TO A SACCH
FILLING (SYS 5, 6, 5bis, 5ter or
meas_info) 727
1500 Measurement received on
an unknown frequency of
neighboring cell 728

1505 No response to BCCH info


(SYS 1, 2, 3, 4, 2 bis, 7, 8, 2 ter,
13) 729
1506 No distribution available for a
cell 730
1508 Data service impact (SYS 13
size exceeded) 731
30034 Background downloaded
action is aborted
Source (30315) BSC restart
occurred 732
Source (30316) Core process is
nullex 732
S8000 Outdoor
1052 GSM entity downloading failure
Source (01) Bad hardware
reference of manufacturer ID 43
Source (03) No change to one of
BOOT states after reset 48
Source (04) This entity is engaged
in another downloading 52
Source (05) Software not
compatible with hardware 54
Source (06) File access error 58
Source (07) Repetitive errors
(NACK, timeout, ...) while
downloading a file 61
Source (08) Wrong software
reference on a non
downloadable TEI 52
Source (14) Received CSM LOAD
CONTAINER NAK 64
Source (16) File to download
unavailable 68
1055 Abis negative acknowledgement indication
Source (02) Equipment unable to
perform such test 285
Source (03) Equipment unable to
perform such configuration 286
Source (05) Cell parameters
inconsistency 288
Source (10) Unknown Abis PCM 293
Source (23) Too many signaling
timeslots 297
Source (25) Out of sequence
message 298
Source (34) The BTS has not
acknowledged the power
consign request 302

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

745

Source (43) Maximum number of


joker TS 309
Source (6) Data inconsistency 290
Source (63) Dynamic Abis feature
not supported 316
Source (64) Inconsistent number
of joker DS0 317
Source (7) Value out of range 291
Source (8) TEI not present 292
1060 Abis event reporting a transient
default
Source (12582924) Frequency
collision on FH bus: eDRX 359
Source (12582935) FACCH
congestion: eDRX 360
Source (12583171) Restart
requested by the BCF: eDRX 360
Source (12583175) Restart due to
hardware watchdog: eDRX 361
Source (12583176) Restart due to
double bus fault: eDRX 362
Source (12583186) BCCH config
dump: eDRX 362
Source (12583202) SACCH config
dump: eDRX 363
Source (12583218) L1M config
dump: eDRX 363
Source (12583219) RSL anomaly:
eDRX 363
Source (12779522) Unknown
message: CMCF phase 1 355
Source (12779556) Restart
requested by the active board:
CMCF phase 1 356
Source (12779558) Restart due
to hardware watchdog: CMCF
phase 1 357
Source (12779559) Restart due to
double bus fault: CMCF phase
1 357
Source (12779560) Reset for new
Lapd parameters: CMCF Ph1 357
Source (12779571) Board reset
asked by OMC: CMCF phase 1 356
Source (12845041) ABIS PCM
statistics: CMCF PH1 358
Source (12845058) Unknown
message: CMCF phase 2 355

Source (12845092) Restart


requested by the active board:
CMCF phase 2 356
Source (12845094) Restart due
to hardware watchdog: CMCF
phase 2 357
Source (12845095) Restart due to
double bus fault: CMCF phase
2 357
Source (12845096) Reset for new
Lapd parameters CMCF Ph2 357
Source (12845107) Board reset
asked by OMC: CMCF phase 2 356
Source (12910577) ABIS PCM
statistics: CMCF PH2 358
Source (12976140) Frequency
collision on FH bus: DRX-ND3 359
Source (12976151) FACCH
congestion: DRX ND3 360
Source (12976387) Restart
requested by the BCF:
DRX-ND3 360
Source (12976389) Restart
due to hardware watchdog:
DRX_ND3 361
Source (12976390) Restart due to
double bus fault: DRX_ND3 362
Source (12976402) BCCH config
dump: DRX_ND3 362
Source (12976418) SACCH config
dump: DRX_ND3 363
Source (12976434) L1M config
dump: DRX_ND3 363
Source (12976435) RSL anomaly:
DRX_ND3 363
Source (15204364) Frequency
collision on FH bus: eDRX2 359
Source (15204375) FACCH
congestion: eDRX2 360
Source (15204611) Restart
requested by the BCF: eDRX2 360
Source (15204615) Restart due to
hardware watchdog: eDRX2 361
Source (15204616) Restart due to
double bus fault: eDRX2 362
Source (15204626) BCCH config
dump: eDRX2 362
Source (15204642) SACCH config
dump: eDRX2 363

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

746

Source (15204658) L1M config


dump: eDRX2 363
Source (15204659) RSL anomaly:
eDRX2 363
Source (15728641) Restart due to
power on: IPM 364
Source (15728642) Restart due to
reset by button: IPM 364
Source (15728643) Restart due to
software upgrade: IPM 365
Source (15728644) Restart due to
hardware watchdog: IPM 365
Source (15728647) IBOS
authentication has failed: IPM 366
Source (15728648) No TCP
connection can be set up with
IGM: IPM 366
Source (15728649) Reset
requested by IGM with no
Ethernet switch reset: IPM 367
Source (15728650) Reset
requested by IGM with Ethernet
switch reset: IPM 367
Source (15728651) Reset
requested by IBOS with BIST
execution and Ethernet switch
reset: IPM 368
Source (15728652) Reset
requested by IBOS with no
BIST execution and Ethernet
switch reset: IPM 368
Source (15728653) Reset
requested by IBOS with BIST
execution and no Ethernet
switch reset: IPM 369
Source (15728654) Reset
requested by IBOS with no
BIST execution nor Ethernet
switch reset: IPM 370
Source (15728655) Restart after
TML commissioning 370
Source (15728656) Connection
with IGM has been lost (no
status received for 7 keep-alive
periods): IPM 371
Source (15728660) Debug 372
Source (15728660) No response
to DNS requests for 15 minutes:
IPM 372
Source (15728674) Soft: IPM 373

Source (15794177) Restart due to


power on: RIPM 373
Source (15794178) Restart due to
reset by button: RIPM 374
Source (15794179) Restart due to
software upgrade: RIPM 374
Source (15794180) Restart due to
hardware watchdog: RIPM 375
Source (15794183) IBOS
authentication has failed: RIPM 375
Source (15794184) No TCP
connection can be set up with
IGM: RIPM 376
Source (15794185) Reset
requested by IGM with no
Ethernet switch reset: RIPM 376
Source (15794186) Reset
requested by IGM with Ethernet
switch reset: RIPM 377
Source (15794187) Reset
requested by IBOS with BIST
execution and Ethernet switch
reset: RIPM 377
Source (15794188) Reset
requested by IBOS with no
BIST execution and Ethernet
switch reset: RIPM 378
Source (15794189) Reset
requested by IBOS with BIST
execution and no Ethernet
switch reset: RIPM 378
Source (15794190) Reset
requested by IBOS with no
BIST execution nor Ethernet
switch reset: RIPM 379
Source (15794192) Connection
with IGM has been lost (no
status received for 7 keep-alive
periods): RIPM 380
Source (15794193) Reset
requested by active with BIST
execution: RIPM 383
Source (15794194) Reset
requested by active with no
BIST execution: RIPM 383
Source (15794195) No response
to DHCP requests for 15
minutes: RIPM 380

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

747

Source (15794196) No response


to DNS requests for 15 minutes:
RIPM 381
Source (15794209) Debug: RIPM 381
Source (15794210) Soft: RIPM 382
Source (15859969) Not enough
synchronization packets have
been received 636
Source (4259878) Restart due to
hardware watchdog: CSWM 358
Source (4259879) Restart due to
double bus fault: CSWM 359
Source (5636098) VSWR level
2: Combiner duplexer vswr or
combiner h2 vswr 524
Source (6553601) Manual switch
on battery power: BRC 351
Source (6553602) Automatic
switch on battery power: BRC 351
Source (6553603) Manual switch
on main power: BRC 351
Source (6553604) Automatic
switch on main power: BRC 352
Source (7536642) VSWR level 2:
TX Filter 384
Source (9437196) Frequency
collision on FH bus: DRX 359
Source (9437207) FACCH
congestion: DRX 360
Source (9437443) Restart
requested by the BCF: DRX 360
Source (9437447) Restart due to
hardware watchdog: DRX 361
Source (9437448) Restart due to
double bus fault: DRX 362
Source (9437458) BCCH config
dump: DRX 362
Source (9437474) SACCH config
dump: DRX 363
Source (9437490) L1M config
dump: DRX 363
Source (9437491) RSL anomaly:
DRX 363
Source (9502722) Unknown
message: CMCF 355
Source (9502756) Restart
requested by the active board:
CMCF 356
Source (9502758) Restart due to
hardware watchdog: CMCF 357

Source (9502759) Restart due to


double bus fault: CMCF 357
Source (9502760) Reset for new
Lapd parameters: CMCF 357
Source (9502771) Board reset
asked by OMC: CMCF 356
Source (9568241) ABIS PCM
statistics: CMCF 358
1063 TRX allocation for a TDMA 386
1067 Abis event reporting a
hardware fault 387
Source (12582913) RX fault:
eDRX 585
Source (12582918) BBFILTER
ASIC fault: eDRX 576
Source (12582921) Self test failed:
eDRX 609
Source (12582922) Major fault on
TX: eDRX 597
Source (12582934) DRX link:
eDRX 591
Source (12582939) PA config.
exceeded: DRX-ND3 573
Source (12582944) The TX has
not ack the power consign
request: eDRX 580
Source (12582945) PA DRX
control loop fault: eDRX 602
Source (12582946) DRX reset by
BCF after message non ack.:
eDRX 602
Source (12582947) DRX link NOK
after reset requested by BSC:
eDRX 596
Source (12583184) BCCH first
config failed: eDRX 589
Source (12583185) BCCH second
config failed: eDRX 590
Source (12583200) SACCH first
config failed: eDRX 607
Source (12583201) SACCH
second config failed: eDRX 608
Source (12583216) L1M first
config failed: eDRX 589
Source (12583217) L1M second
config failed: eDRX 597
Source (12648447) TRX not
anymore configured: eDRX 613
Source (12648449 ) Hardware:
ePA 652

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

748

Source (12648450) DRX and PA


connection: ePA 658
Source (12648451) High temp:
ePA 663
Source (12648452) High current:
ePA 667
Source (12648454) PA_PSDW:
ePA 671
Source (12713985) Hardware:
(H)(e)PA 652
Source (12713986) DRX and PA
connection: HePA 658
Source (12713987) High temp:
HePA 663
Source (12713988) High current:
HePA 667
Source (12713990) PA_PSDW:
HePA 671
Source (12779529) MCF_MCF:
CMCF phase 1 507
Source (12779538) CMCF ACT
DUPLEX INHIBITED: CMCF
phase 1 512
Source (12779539) CMCF ACT
ICST: CMCF phase 1 515
Source (12779540) Duplex
inhibited: feature not supported
on CMCF phase 1: CMCF
phase 1 517
Source (12845050) Slave
downloading error: CMCF
phase 1 510
Source (12845065) MCF_MCF:
CMCF phase 2 507
Source (12845074) CMCF ACT
DUPLEX INHIBITED: CMCF
phase 2 512
Source (12845075) CMCF ACT
ICST: CMCF phase 2 515
Source (12910586) Slave
downloading error: CMCF
phase 2 510
Source (12976129) RX fault:
DRX-ND3 585
Source (12976134) BBFILTER
ASIC fault: DRX-ND3 576
Source (12976137) Self test failed:
DRX-ND3 609
Source (12976138) Major fault on
TX: DRX-ND3 597

Source (12976150) DRX link:


DRX-ND3 591
Source (12976158) Abis satellite
not supported DRX ND3:
DRX-ND3 569
Source (12976160) The TX has
not ack the power consign
request: DRX-ND3 580
Source (12976161) PA DRX
control loop fault: DRX-ND3 602
Source (12976162) DRX reset by
BCF after message non ack.:
DRX-ND3 602
Source (12976163) DRX link NOK
after reset requested by BSC:
DRX-ND3 596
Source (12976400) BCCH first
config failed: DRX-ND3 589
Source (12976401) BCCH second
config failed: DRX-ND3 590
Source (12976416) SACCH first
config failed: DRX-ND3 607
Source (12976417) SACCH
second config failed: DRX-ND3 608
Source (12976432) L1M first
config failed: DRX-ND3 589
Source (12976433) L1M second
config failed: DRX-ND3 597
Source (13041663) TRX not
anymore configured: DRX-ND3 613
Source (15204361) Self test failed:
eDRX2 609
Source (15204362) Major fault on
TX: eDRX2 597
Source (15204374) DRX link:
eDRX2 591
Source (15204385) PA DRX
control loop fault: eDRX2 602
Source (15204386) DRX reset by
BCF after message non ack.:
eDRX2 602
Source (15204387) DRX link NOK
after reset requested by BSC:
eDRX2 596
Source (15204624) BCCH first
config failed: eDRX2 589
Source (15204625) BCCH second
config failed: eDRX2 590
Source (15204640) SACCH first
config failed: eDRX2 607

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

749

Source (15204641) SACCH


second config failed: eDRX2 608
Source (15204656) L1M first
config failed: eDRX2 589
Source (15204657) L1M second
config failed: eDRX2 597
Source (15269887) TRX not
anymore configured: eDRX2 613
Source (15663140) Only one IBOS
commissioned at IPM: IPM
commissioning 637
Source (15663141) DNS
resolution has failed for at least
one IBOS: IPM commissioning 638
Source (15728672) BIST failed:
IPM 639
Source (15728675) Temperature:
IPM 640
Source (15728688) DAC unable
to lock, synchronization not
possible: IPM 641
Source (15794208) BIST failed:
RIPM 699
Source (15794211) Temperature:
IPM 700
Source (15794224) DAC unable
to lock, synchronization not
possible: IPM 701
Source (15794241) No link with
passive: RIPM 703
Source (15859968) Unable to
lock on IP synchronization: IP
synchro 634
Source (3342340) SYNO clock
not locked on the network: BTS
synchronization 441
Source (3342341) Synchro not
locked because OCVXO is KO:
BTS synchronization 448
Source (3342343) GPS
synchronization unavailable:
BTS synchronization 451
Source (3342344) Loss of
GPS synchronization: BTS
synchronization 456
Source (3342345) Lack of GPS
synchronization accuracy: BTS
synchronization 461

Source (3342346) Master


synchronization unavailable:
BTS synchronization 466
Source (3342347) Loss of
master GSM time: BTS
synchronization 471
Source (3342348) Loss of master
SY: BTS sunchronization 475
Source (3735553) Alarm: Not
protected alarm 646
Source (4259849) Fault on
active-passive CSWM link
or passive CSWM: CSWM 544
Source (4325370) Slave
downloading error: CSWM 547
Source (4325377) Major fault on
SYNC: SYNC 707
Source (4390913) Major fault:
ALCO 416
Source (4456453) Channel_HSCX: DSC 618
Source (4521985) Major fault:
PCMI 652
Source (4587521) Major fault on
GTW: GTW 628
Source (5242881) AC fault:
Rectifier 48V 682
Source (5242882) DC fault:
Rectifier 48V 686
Source (5242883) Over
temperature: Rectifier 48V 688
Source (5242884) External battery
level 1: Rectifier 48V 691
Source (5242885) PCU protective:
Rectifier 48V 693
Source (5242886) Battery on
discharges: Rectifier 48V 697
Source (5308417) Volt: Converter
F 624
Source (5373953) Volt: Converter
BCF 435
Source (5439489) Battery
disconnected: Internal battery
system 631
Source (5505031) Cooler fault:
Cooler system 413
Source (5570561) LNA fault:
Combiner duplexer LNA or
combiner H2 LNA 520

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

750

Source (5636097) VSWR level


1: Combiner duplexer vswr or
combiner h2 vswr 524
Source (5636099) VSWR level
3: Combiner duplexer vswr or
combiner h2 vswr 525
Source (5767169) Main breaker:
Distribution system 557
Source (5832705) Over
temperature: battery cabinet 419
Source (5832706) DC power fault:
battery cabinet 422
Source (5832707) Doors: battery
cabinet 425
Source (5898241) Door contact
detection: Door contact 479
Source (6160385) Lightning
protection fault: Lightning
Protection 643
Source (6488065) PCM: PCM 652
Source (6553601) Manual switch
on battery power: BRC 438
Source (6553602) Automatic
switch on battery power: BRC 438
Source (6553603) Manual switch
on main power: BRC 438
Source (6553604) Automatic
switch on main power: BRC 438
Source (6553605) Battery failure:
BRC 439
Source (6553606) Monitored
battery not present: BRC 440
Source (6553607) Internal
inconsistency: BRC 441
Source (6815745) Hardware: PA 652
Source (6815746) DRX and PA
connection: PA 658
Source (6815747) High temp: PA 663
Source (6815748) High current:
PA 667
Source (6815750) PA_PSDW: PA 671
Source (6815751) VSWR fault
detected by PA: PA 675
Source (6881281) Software
detection: DRX main reception
chain 565
Source (6881281) Software
detection: DRX-ND3 main
reception chain 565

Source (6946817) Software


detection: DRX diversity
reception chain 560
Source (6946817) Software
detection: DRX-ND3 diversity
reception chain 560
Source (7274497) External alarm 621
Source (7405569) LNA fault:
Combiner h4 lna (LNA) 528
Source (7471105) VSWR level 1:
Combiner h4 vswr (VSWR) 532
Source (7471106) VSWR level 2:
Combiner h4 vswr (VSWR) 534
Source (7471107) VSWR level 3:
Combiner h4 vswr (VSWR) 536
Source (7536643) VSWR level 3:
Txfilter (VSWR) 710
Source (7864321) Dirty filter:
dacsCooler 549
Source (7864322) DACS failed:
dacsCooler 551
Source (9437185) RX fault: DRX 585
Source (9437190) BBFILTER
ASIC fault: DRX 576
Source (9437193) Self test failed:
DRX 609
Source (9437194)Major fault on
TX: DRX 597
Source (9437206) DRX link: DRX 591
Source (9437211) PA config.
exceeded: DRX 573
Source (9437212) HePA not
supported: DRX 570
Source (9437214) Abis satellite
not supported DRX: DRX 569
Source (9437216) The TX has not
ack the power consign request:
DRX 580
Source (9437217) PA DRX control
loop fault: DRX 602
Source (9437218) DRX reset by
BCF after message non ack.:
DRX 602
Source (9437219) DRX link NOK
after reset requested by BSC:
DRX 596
Source (9437456) BCCH first
config failed: DRX 589
Source (9437457) BCCH second
config failed: DRX 590

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

751

Source (9437472) SACCH first


config failed: DRX 607
Source (9437473) SACCH second
config failed: DRX 608
Source (9437488) L1M first config
failed: DRX 589
Source (9437489) L1M second
config failed: DRX 597
Source (9502719) TRX not
anymore configured: DRX 613
Source (9502729) MCF_MCF:
CMCF 507
Source (9568250) Slave
downloading error: CMCF 510
Source (9568257) Major fault:
CPCMI 541
Source (9633786) Slave
downloading error: CPCMI 541
Source (9633793) Major: RECAL 676
Source (9699322) Slave
downloading error: RECAL 679
Source (9699329) Over current:
Rx splitter M 649
Source (9764865) Over current:
Rx splitter D 646
Source 4456449) Major fault:
DSC 616
Source 7602177) LNA fault: Rx
Filter (LNA) 704
1067 Abis event reporting a transient
default
Source (7536642) VSWR level 2:
Tx filter (VSWR) 709
1070 TRX synchronization failure 712
1073 Attempt of download failure on
a GSM entity 712
Source (09) No response to load
message 718
Source (10) Received LOAD INIT
NACK 718
Source (11) Received LOAD DATA
NACK 718
Source (12) Received LOAD END
NACK 718
Source (13) Received LOAD
READY NACK 718
1077 Update of the activation status
of a site 719
1213 Secured loop unavailable 721
1214 Secured loop problem 722

1258 No BTS response on


preprocessing configuration 722
1259 Negative acknowledgement on
preprocessing command 724
1265 Blockage of radio channel(s) in
busy state 725
1266 Blockage of radio channel(s) in
free state 726
1268 NO RESPONSE TO A SACCH
FILLING (SYS 5, 6, 5bis, 5ter or
meas_info) 727
1500 Measurement received on
an unknown frequency of
neighboring cell 728
1505 No response to BCCH info
(SYS 1, 2, 3, 4, 2 bis, 7, 8, 2 ter,
13) 729
1506 No distribution available for a
cell 730
1508 Data service impact (SYS 13
size exceeded) 731
30034 Background downloaded
action is aborted
Source (30315) BSC restart
occurred 732
Source (30316) Core process is
nullex 732
S8002
1052 GSM entity downloading failure
Source (01) Bad hardware
reference of manufacturer ID 43
Source (03) No change to one of
BOOT states after reset 48
Source (04) This entity is engaged
in another downloading 52
Source (05) Software not
compatible with hardware 54
Source (06) File access error 58
Source (07) Repetitive errors
(NACK, timeout, ...) while
downloading a file 61
Source (08) Wrong software
reference on a non
downloadable TEI 52
Source (14) Received CSM LOAD
CONTAINER NAK 64
Source (16) File to download
unavailable 68
1055 Abis negative acknowledgement indication

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

752

Source (02) Equipment unable to


perform such test 285
Source (03) Equipment unable to
perform such configuration 286
Source (05) Cell parameters
inconsistency 288
Source (10) Unknown Abis PCM 293
Source (23) Too many signaling
timeslots 297
Source (25) Out of sequence
message 298
Source (34) The BTS has not
acknowledged the power
consign request 302
Source (43) Maximum number of
joker TS 309
Source (6) Data inconsistency 290
Source (63) Dynamic Abis feature
not supported 316
Source (64) Inconsistent number
of joker DS0 317
Source (7) Value out of range 291
Source (8) TEI not present 292
1060 Abis event reporting a transient
default
Source (12582924) Frequency
collision on FH bus: eDRX 359
Source (12582935) FACCH
congestion: eDRX 360
Source (12583171) Restart
requested by the BCF: eDRX 360
Source (12583175) Restart due to
hardware watchdog: eDRX 361
Source (12583176) Restart due to
double bus fault: eDRX 362
Source (12583186) BCCH config
dump: eDRX 362
Source (12583202) SACCH config
dump: eDRX 363
Source (12583218) L1M config
dump: eDRX 363
Source (12583219) RSL anomaly:
eDRX 363
Source (12779522) Unknown
message: CMCF phase 1 355
Source (12779556) Restart
requested by the active board:
CMCF phase 1 356

Source (12779558) Restart due


to hardware watchdog: CMCF
phase 1 357
Source (12779559) Restart due to
double bus fault: CMCF phase
1 357
Source (12779560) Reset for new
Lapd parameters: CMCF Ph1 357
Source (12779571) Board reset
asked by OMC: CMCF phase 1 356
Source (12845041) ABIS PCM
statistics: CMCF PH1 358
Source (12845058) Unknown
message: CMCF phase 2 355
Source (12845092) Restart
requested by the active board:
CMCF phase 2 356
Source (12845094) Restart due
to hardware watchdog: CMCF
phase 2 357
Source (12845095) Restart due to
double bus fault: CMCF phase
2 357
Source (12845096) Reset for new
Lapd parameters CMCF Ph2 357
Source (12845107) Board reset
asked by OMC: CMCF phase 2 356
Source (12910577) ABIS PCM
statistics: CMCF PH2 358
Source (12976140) Frequency
collision on FH bus: DRX-ND3 359
Source (12976151) FACCH
congestion: DRX ND3 360
Source (12976387) Restart
requested by the BCF:
DRX-ND3 360
Source (12976389) Restart
due to hardware watchdog:
DRX_ND3 361
Source (12976390) Restart due to
double bus fault: DRX_ND3 362
Source (12976402) BCCH config
dump: DRX_ND3 362
Source (12976418) SACCH config
dump: DRX_ND3 363
Source (12976434) L1M config
dump: DRX_ND3 363
Source (12976435) RSL anomaly:
DRX_ND3 363

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

753

Source (15204611) Restart


requested by the BCF: eDRX2 360
Source (4259878) Restart due to
hardware watchdog: CSWM 358
Source (4259879) Restart due to
double bus fault: CSWM 359
Source (6553601) Manual switch
on battery power: BRC 351
Source (6553602) Automatic
switch on battery power: BRC 351
Source (6553603) Manual switch
on main power: BRC 351
Source (6553604) Automatic
switch on main power: BRC 352
Source (9437196) Frequency
collision on FH bus: DRX 359
Source (9437207) FACCH
congestion: DRX 360
Source (9437443) Restart
requested by the BCF: DRX 360
Source (9437447) Restart due to
hardware watchdog: DRX 361
Source (9437448) Restart due to
double bus fault: DRX 362
Source (9437458) BCCH config
dump: DRX 362
Source (9437474) SACCH config
dump: DRX 363
Source (9437490) L1M config
dump: DRX 363
Source (9437491) RSL anomaly:
DRX 363
Source (9502722) Unknown
message: CMCF 355
Source (9502756) Restart
requested by the active board:
CMCF 356
Source (9502758) Restart due to
hardware watchdog: CMCF 357
Source (9502759) Restart due to
double bus fault: CMCF 357
Source (9502760) Reset for new
Lapd parameters: CMCF 357
Source (9502771) Board reset
asked by OMC: CMCF 356
Source (9568241) ABIS PCM
statistics: CMCF 358
1063 TRX allocation for a TDMA 386
1067 Abis event reporting a
hardware fault 387

Source (12582913) RX fault:


eDRX 585
Source (12582918) BBFILTER
ASIC fault: eDRX 576
Source (12582921) Self test failed:
eDRX 609
Source (12582922) Major fault on
TX: eDRX 597
Source (12582934) DRX link:
eDRX 591
Source (12582939) PA config.
exceeded: DRX-ND3 573
Source (12582944) The TX has
not ack the power consign
request: eDRX 580
Source (12582945) PA DRX
control loop fault: eDRX 602
Source (12582946) DRX reset by
BCF after message non ack.:
eDRX 602
Source (12582947) DRX link NOK
after reset requested by BSC:
eDRX 596
Source (12583184) BCCH first
config failed: eDRX 589
Source (12583185) BCCH second
config failed: eDRX 590
Source (12583200) SACCH first
config failed: eDRX 607
Source (12583201) SACCH
second config failed: eDRX 608
Source (12583216) L1M first
config failed: eDRX 589
Source (12583217) L1M second
config failed: eDRX 597
Source (12648449 ) Hardware:
ePA 652
Source (12648450) DRX and PA
connection: ePA 658
Source (12648451) High temp:
ePA 663
Source (12648452) High current:
ePA 667
Source (12648454) PA_PSDW:
ePA 671
Source (12713985) Hardware:
(H)(e)PA 652
Source (12713986) DRX and PA
connection: HePA 658

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

754

Source (12713987) High temp:


HePA 663
Source (12713988) High current:
HePA 667
Source (12713990) PA_PSDW:
HePA 671
Source (12779529) MCF_MCF:
CMCF phase 1 507
Source (12779538) CMCF ACT
DUPLEX INHIBITED: CMCF
phase 1 512
Source (12779539) CMCF ACT
ICST: CMCF phase 1 515
Source (12779540) Duplex
inhibited: feature not supported
on CMCF phase 1: CMCF
phase 1 517
Source (12845050) Slave
downloading error: CMCF
phase 1 510
Source (12845065) MCF_MCF:
CMCF phase 2 507
Source (12845074) CMCF ACT
DUPLEX INHIBITED: CMCF
phase 2 512
Source (12845075) CMCF ACT
ICST: CMCF phase 2 515
Source (12910586) Slave
downloading error: CMCF
phase 2 510
Source (12976129) RX fault:
DRX-ND3 585
Source (12976134) BBFILTER
ASIC fault: DRX-ND3 576
Source (12976137) Self test failed:
DRX-ND3 609
Source (12976138) Major fault on
TX: DRX-ND3 597
Source (12976150) DRX link:
DRX-ND3 591
Source (12976158) Abis satellite
not supported DRX ND3:
DRX-ND3 569
Source (12976160) The TX has
not ack the power consign
request: DRX-ND33 580
Source (12976161) PA DRX
control loop fault: DRX-ND3 602

Source (12976162) DRX reset by


BCF after message non ack.:
DRX-ND3 602
Source (12976163) DRX link NOK
after reset requested by BSC:
DRX-ND3 596
Source (12976400) BCCH first
config failed: DRX-ND3 589
Source (12976401) BCCH second
config failed: DRX-ND3 590
Source (12976416) SACCH first
config failed: DRX-ND3 607
Source (12976417) SACCH
second config failed: DRX-ND3 608
Source (12976432) L1M first
config failed: DRX-ND3 589
Source (12976433) L1M second
config failed: DRX-ND3 597
Source (3342340) SYNO clock
not locked on the network: BTS
synchronization 441
Source (3342341) Synchro not
locked because OCVXO is KO:
BTS synchronization 448
Source (3735553) Alarm: Not
protected alarm 646
Source (5242881) AC fault:
Rectifier 48V 682
Source (5242882) DC fault:
Rectifier 48V 686
Source (5242883) Over
temperature: Rectifier 48V 688
Source (5242885) PCU protective:
Rectifier 48V 693
Source (5242886) Battery on
discharges: Rectifier 48V 697
Source (5308417) Volt: Converter
F 624
Source (5439489) Battery
disconnected: Internal battery
system 631
Source (5570561) LNA fault:
Combiner duplexer LNA or
combiner H2 LNA 520
Source (5636097) VSWR level
1: Combiner duplexer vswr or
combiner h2 vswr 524
Source (5636098) VSWR level
2: Combiner duplexer vswr or
combiner h2 vswr 524

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

755

Source (5636099) VSWR level


3: Combiner duplexer vswr or
combiner h2 vswr 525
Source (5767169) Main breaker:
Distribution system 557
Source (5898241) Door contact
detection: Door contact 479
Source (6160385) Lightning
protection fault: Lightning
Protection 643
Source (6488065) PCM: PCM 652
Source (6553601) Manual switch
on battery power: BRC 438
Source (6553602) Automatic
switch on battery power: BRC 438
Source (6553603) Manual switch
on main power: BRC 438
Source (6553604) Automatic
switch on main power: BRC 438
Source (6553605) Battery failure:
BRC 439
Source (6815745) Hardware: PA 652
Source (6815746) DRX and PA
connection: PA 658
Source (6815747) High temp: PA 663
Source (6815748) High current:
PA 667
Source (6815750) PA_PSDW: PA 671
Source (6815751) VSWR fault
detected by PA: PA 675
Source (6881281) Software
detection: DRX main reception
chain 565
Source (6881281) Software
detection: DRX-ND3 main
reception chain 565
Source (6946817) Software
detection: DRX diversity
reception chain 560
Source (6946817) Software
detection: DRX-ND3 diversity
reception chain 560
Source (7274497) External alarm 621
Source (7929857) Dirty filter:
Compact dacs cooler 502
Source (7929858) DACS failed:
Compact dacs cooler 504
Source (7995393) Main breaker:
Compact distribution 538
Source (9437185) RX fault: DRX 585

Source (9437190) BBFILTER


ASIC fault: DRX 576
Source (9437193) Self test failed:
DRX 609
Source (9437194) Major fault on
TX: DRX 597
Source (9437206) DRX link: DRX 591
Source (9437211) PA config.
exceeded: DRX 573
Source (9437212) HePA not
supported: DRX 570
Source (9437214) Abis satellite
not supported DRX: DRX 569
Source (9437216) The TX has not
ack the power consign request:
DRX 580
Source (9437217) PA DRX control
loop fault: DRX 602
Source (9437218) DRX reset by
BCF after message non ack.:
DRX 602
Source (9437219) DRX link NOK
after reset requested by BSC:
DRX 596
Source (9437456) BCCH first
config failed: DRX 589
Source (9437457) BCCH second
config failed: DRX 590
Source (9437472) SACCH first
config failed: DRX 607
Source (9437473) SACCH second
config failed: DRX 608
Source (9437488) L1M first config
failed: DRX 589
Source (9437489) L1M second
config failed: DRX 597
Source (9502729) MCF_MCF:
CMCF 507
Source (9568250) Slave
downloading error: CMCF 510
Source (9568257) Major fault:
CPCMI 541
Source (9633786) Slave
downloading error: CPCMI 541
Source (9633793) Major: RECAL 676
Source (9699322) Slave
downloading error: RECAL 679
Source (9699329) Over current:
Rx splitter M 649

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

756

Source (9764865) Over current:


Rx splitter D 646
1070 TRX synchronization failure 712
1073 Attempt of download failure on
a GSM entity 712
Source (09) No response to load
message 718
Source (10) Received LOAD INIT
NACK 718
Source (11) Received LOAD DATA
NACK 718
Source (12) Received LOAD END
NACK 718
Source (13) Received LOAD
READY NACK 718
1077 Update of the activation status
of a site 719
1080 Access fault 720
1213 Secured loop unavailable 721
1214 Secured loop problem 722
1258 No BTS response on
preprocessing configuration 722
1259 Negative acknowledgement on
preprocessing command 724
1265 Blockage of radio channel(s) in
busy state 725
1266 Blockage of radio channel(s) in
free state 726
1268 NO RESPONSE TO A SACCH
FILLING (SYS 5, 6, 5bis, 5ter or
meas_info) 727
1500 Measurement received on
an unknown frequency of
neighboring cell 728
1505 No response to BCCH info
(SYS 1, 2, 3, 4, 2 bis, 7, 8, 2 ter,
13) 729
1506 No distribution available for a
cell 730
1508 Data service impact (SYS 13
size exceeded) 731
30034 Background downloaded
action is aborted
Source (30315) BSC restart
occurred 732
Source (30316) Core process is
nullex 732
S8003
1052 GSM entity downloading failure

Source (01) Bad hardware


reference of manufacturer ID 43
Source (03) No change to one of
BOOT states after reset 48
Source (04) This entity is engaged
in another downloading 52
Source (05) Software not
compatible with hardware 54
Source (06) File access error 58
Source (07) Repetitive errors
(NACK, timeout, ...) while
downloading a file 61
Source (08) Wrong software
reference on a non
downloadable TEI 52
Source (14) Received CSM LOAD
CONTAINER NAK 64
Source (16) File to download
unavailable 68
1055 Abis negative acknowledgement indication
Source (02) Equipment unable to
perform such test 285
Source (03) Equipment unable to
perform such configuration 286
Source (05) Cell parameters
inconsistency 288
Source (10) Unknown Abis PCM 293
Source (23) Too many signaling
timeslots 297
Source (25) Out of sequence
message 298
Source (34) The BTS has not
acknowledged the power
consign request 302
Source (43) Maximum number of
joker TS 309
Source (6) Data inconsistency 290
Source (63) Dynamic Abis feature
not supported 316
Source (64) Inconsistent number
of joker DS0 317
Source (7) Value out of range 291
Source (8) TEI not present 292
1060 Abis event reporting a transient
default 363
Source (12582924) Frequency
collision on FH bus: eDRX 359
Source (12582935) FACCH
congestion: eDRX 360

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

757

Source (12583171) Restart


requested by the BCF: eDRX 360
Source (12583175) Restart due to
hardware watchdog: eDRX 361
Source (12583176) Restart due to
double bus fault: eDRX 362
Source (12583186) BCCH config
dump: eDRX 362
Source (12583202) SACCH config
dump: eDRX 363
Source (12583218) L1M config
dump: eDRX 363
Source (12779522) Unknown
message: CMCF phase 1 355
Source (12779556) Restart
requested by the active board:
CMCF phase 1 356
Source (12779558) Restart due
to hardware watchdog: CMCF
phase 1 357
Source (12779559) Restart due to
double bus fault: CMCF phase
1 357
Source (12779560) Reset for new
Lapd parameters: CMCF Ph1 357
Source (12779571) Board reset
asked by OMC: CMCF phase 1 356
Source (12845041) ABIS PCM
statistics: CMCF PH1 358
Source (12845058) Unknown
message: CMCF phase 2 355
Source (12845092) Restart
requested by the active board:
CMCF phase 2 356
Source (12845094) Restart due
to hardware watchdog: CMCF
phase 2 357
Source (12845095) Restart due to
double bus fault: CMCF phase
2 357
Source (12845096) Reset for new
Lapd parameters CMCF Ph2 357
Source (12845107) Board reset
asked by OMC: CMCF phase 2 356
Source (12910577) ABIS PCM
statistics: CMCF PH2 358
Source (12976140) Frequency
collision on FH bus: DRX-ND3 359
Source (12976151) FACCH
congestion: DRX ND3 360

Source (12976387) Restart


requested by the BCF:
DRX-ND3 360
Source (12976389) Restart
due to hardware watchdog:
DRX_ND3 361
Source (12976390) Restart due to
double bus fault: DRX_ND3 362
Source (12976402) BCCH config
dump: DRX_ND3 362
Source (12976418) SACCH config
dump: DRX_ND3 363
Source (12976434) L1M config
dump: DRX_ND3 363
Source (12976435) RSL anomaly:
DRX_ND3 363
Source (15204364) Frequency
collision on FH bus: eDRX2 359
Source (15204375) FACCH
congestion: eDRX2 360
Source (15204611) Restart
requested by the BCF: eDRX2 360
Source (15204615) Restart due to
hardware watchdog: eDRX2 361
Source (15204616) Restart due to
double bus fault: eDRX2 362
Source (15204626) BCCH config
dump: eDRX2 362
Source (15204642) SACCH config
dump: eDRX2 363
Source (15204658) L1M config
dump: eDRX2 363
Source (15204659) RSL anomaly:
eDRX2 363
Source (7536642) VSWR level 2:
TX Filter 384
Source (9437196) Frequency
collision on FH bus: DRX 359
Source (9437207) FACCH
congestion: DRX 360
Source (9437443) Restart
requested by the BCF: DRX 360
Source (9437447) Restart due to
hardware watchdog: DRX 361
Source (9437448) Restart due to
double bus fault: DRX 362
Source (9437458) BCCH config
dump: DRX 362
Source (9437474) SACCH config
dump: DRX 363

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

758

Source (9437490) L1M config


dump: DRX 363
Source (9437491) RSL anomaly:
DRX 363
Source (9502722) Unknown
message: CMF 355
Source (9502756) Restart
requested by the active board:
CMCF 356
Source (9502758) Restart due to
hardware watchdog: CMCF 357
Source (9502759) Restart due to
double bus fault: CMCF 357
Source (9502760) Reset for new
Lapd parameters: CMCF 357
Source (9502771) Board reset
asked by OMC: CMCF 356
Source (9568241) ABIS PCM
statistics: CMCF 358
1063 TRX allocation for a TDMA 386
1067 Abis event reporting a
hardware fault 387, 712
Source (12582913) RX fault:
eDRX 585
Source (12582918) BBFILTER
ASIC fault: eDRX 576
Source (12582921) Self test failed:
eDRX 609
Source (12582922) Major fault on
TX: eDRX 597
Source (12582934) DRX link:
eDRX 591
Source (12582939) PA config.
exceeded: DRX-ND3 573
Source (12582944) The TX has
not ack the power consign
request: eDRX 580
Source (12582945) PA DRX
control loop fault: eDRX 602
Source (12582946) DRX reset by
BCF after message non ack.:
eDRX 602
Source (12582947) DRX link NOK
after reset requested by BSC:
eDRX 596
Source (12583184) BCCH first
config failed: eDRX 589
Source (12583185) BCCH second
config failed: eDRX 590

Source (12583200) SACCH first


config failed: eDRX 607
Source (12583201) SACCH
second config failed: eDRX 608
Source (12583216) L1M first
config failed: eDRX 589
Source (12583217) L1M second
config failed: eDRX 597
Source (12648447) TRX not
anymore configured: eDRX 613
Source (12648449) Hardware:
ePA 652
Source (12648450) DRX and PA
connection: ePA 658
Source (12648451) High temp:
ePA 663
Source (12648452) High current:
ePA 667
Source (12648454) PA_PSDW:
ePA 671
Source (12713985) Hardware:
(H)(e)PA 652
Source (12713986) DRX and PA
connection: HePA 658
Source (12713987) High temp:
HePA 663
Source (12713988) High current:
HePA 667
Source (12713990) PA_PSDW:
HePA 671
Source (12779529) MCF_MCF:
CMCF phase 1 507
Source (12779538) CMCF ACT
DUPLEX INHIBITED: CMCF
phase 1 512
Source (12779539) CMCF ACT
ICST: CMCF phase 1 515
Source (12779540) Duplex
inhibited: feature not supported
on CMCF phase 1: CMCF
phase 1 517
Source (12845050) Slave
downloading error: CMCF
phase 1 510
Source (12845065) MCF_MCF:
CMCF phase 2 507
Source (12845074) CMCF ACT
DUPLEX INHIBITED: CMCF
phase 2 512

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

759

Source (12845075) CMCF ACT


ICST: CMCF phase 2 515
Source (12910586) Slave
downloading error: CMCF
phase 2 510
Source (12976129) RX fault:
DRX-ND3 585
Source (12976134) BBFILTER
ASIC fault: DRX-ND3 576
Source (12976137) Self test failed:
DRX-ND3 609
Source (12976138) Major fault on
TX: DRX-ND3 597
Source (12976150) DRX link:
DRX-ND3 591
Source (12976158) Abis satellite
not supported DRX ND3:
DRX-ND3 569
Source (12976160) The TX has
not ack the power consign
request: DRX-ND3 580
Source (12976161) PA DRX
control loop fault: DRX-ND3 602
Source (12976162) DRX reset by
BCF after message non ack.:
DRX-ND3 602
Source (12976163) DRX link NOK
after reset requested by BSC:
DRX-ND3 596
Source (12976400) BCCH first
config failed: DRX-ND3 589
Source (12976401) BCCH second
config failed: DRX-ND3 590
Source (12976416) SACCH first
config failed: DRX-ND3 607
Source (12976417) SACCH
second config failed: DRX-ND3 608
Source (12976432) L1M first
config failed: DRX-ND3 589
Source (12976433) L1M second
config failed: DRX-ND3 597
Source (13041663) TRX not
anymore configured: DRX-ND3 613
Source (15204361) Self test failed:
eDRX2 609
Source (15204362) Major fault on
TX: eDRX2 597
Source (15204374) DRX link:
eDRX2 591

Source (15204385) PA DRX


control loop fault: eDRX2 602
Source (15204386) DRX reset by
BCF after message non ack.:
eDRX2 602
Source (15204387) DRX link NOK
after reset requested by BSC:
eDRX2 596
Source (15204624) BCCH first
config failed: eDRX2 589
Source (15204625) BCCH second
config failed: eDRX2 590
Source (15204640) SACCH first
config failed: eDRX2 607
Source (15204641) SACCH
second config failed: eDRX2 608
Source (15204656) L1M first
config failed: eDRX2 589
Source (15204657) L1M second
config failed: eDRX2 597
Source (15269887) TRX not
anymore configured: eDRX2 613
Source (3342340) SYNO clock
not locked on the network: BTS
synchronization 441
Source (3342341) Synchro not
locked because OCVXO is KO:
BTS synchronization 448
Source (3735553) Alarm: Not
protected alarm 646
Source (5308417) Volt: Converter
F 624
Source (5570561) LNA fault:
Combiner duplexer LNA or
combiner H2 LNA 520
Source (5636097) VSWR level
1: Combiner duplexer vswr or
combiner h2 vswr 524
Source (5636098) VSWR level
2: Combiner duplexer vswr or
combiner h2 vswr 524
Source (5636099) VSWR level
3: Combiner duplexer vswr or
combiner h2 vswr 525
Source (5898241) Door contact
detection: Door contact 479
Source (6225921) Cabinet fan
fault: Cabinet fan 621
Source (6488065) PCM: PCM 652
Source (6815745) Hardware: PA 652

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

760

Source (6815746) DRX and PA


connection: PA 658
Source (6815747) High temp: PA
Source (6815748) High current:
PA 667
Source (6815750) PA_PSDW: PA
Source (6815751) VSWR fault
detected by PA: PA 675
Source (6881281) Software
detection: DRX main reception
chain 565
Source (6881281) Software
detection: DRX-ND3 main
reception chain 565
Source (6946817) Software
detection: DRX diversity
reception chain 560
Source (6946817) Software
detection: DRX-ND3 diversity
reception chain 560
Source (7274497) External alarm
Source (7536643) VSWR level 3:
Txfilter (VSWR) 710
Source (9437185) RX fault: DRX
Source (9437190) BBFILTER
ASIC fault: DRX 576
Source (9437193) Self test failed:
DRX 609
Source (9437194) Major fault on
TX: DRX 597
Source (9437206) DRX link: DRX
Source (9437211) PA config.
exceeded: DRX 573
Source (9437212) HePA not
supported: DRX 570
Source (9437214) Abis satellite
not supported DRX: DRX 569
Source (9437216) The TX has not
ack the power consign request:
DRX 580
Source (9437217) PA DRX control
loop fault: DRX 602
Source (9437218) DRX reset by
BCF after message non ack.:
DRX 602
Source (9437219) DRX link NOK
after reset requested by BSC:
DRX 596
Source (9437456) BCCH first
config failed: DRX 589

663
671

621
585

591

Source (9437457) BCCH second


config failed: DRX 590
Source (9437472) SACCH first
config failed: DRX 607
Source (9437473) SACCH second
config failed: DRX 608
Source (9437488) L1M first config
failed: DRX 589
Source (9437489) L1M second
config failed: DRX 597
Source (9502719) TRX not
anymore configured: DRX 613
Source (9502729) MCF_MCF:
CMCF 507
Source (9568250) Slave
downloading error: CMCF 510
Source (9633786) Slave
downloading error: CPCMI 541
Source (9633793) Major: RECAL 676
Source (9699322) Slave
downloading error: RECAL 679
Source (9764865) Over current:
Rx splitter D 646
Source 7602177) LNA fault: Rx
Filter (LNA) 704
1067 Abis event reporting a transient
default
Source (7536642) VSWR level 2:
Tx filter (VSWR) 709
1070 TRX synchronization failure 712
1073 Attempt of download failure on
a GSM entity
Source (09) No response to load
message 718
Source (10) Received LOAD INIT
NACK 718
Source (11) Received LOAD DATA
NACK 718
Source (12) Received LOAD END
NACK 718
Source (13) Received LOAD
READY NACK 718
1077 Update of the activation status
of a site 719
1080 Access fault 720
1213 Secured loop unavailable 721
1214 Secured loop problem 722
1258 No BTS response on
preprocessing configuration 722

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

761

1259 Negative acknowledgement on


preprocessing command 724
1265 Blockage of radio channel(s) in
busy state 725
1266 Blockage of radio channel(s) in
free state 726
1268 NO RESPONSE TO A SACCH
FILLING (SYS 5, 6, 5bis, 5ter or
meas_info) 727
1500 Measurement received on
an unknown frequency of
neighboring cell 728
1505 No response to BCCH info
(SYS 1, 2, 3, 4, 2 bis, 7, 8, 2 ter,
13) 729
1506 No distribution available for a
cell 730
1508 Data service impact (SYS 13
size exceeded) 731
30034 Background downloaded
action is aborted
Source (30315) BSC restart
occurred 732
Source (30316) Core process is
nullex 732
S8006
1067 Abis event reporting a
hardware fault 569
1052 GSM entity downloading failure
Source (01) Bad hardware
reference of manufacturer ID 43
Source (03) No change to one of
BOOT states after reset 48
Source (04) This entity is engaged
in another downloading 52
Source (05) Software not
compatible with hardware 54
Source (06) File access error 58
Source (07) Repetitive errors
(NACK, timeout, ...) while
downloading a file 61
Source (08) Wrong software
reference on a non
downloadable TEI 52
Source (14) Received CSM LOAD
CONTAINER NAK 64
Source (16) File to download
unavailable 68
1055 Abis negative acknowledgement indication

Source (02) Equipment unable to


perform such test 285
Source (03) Equipment unable to
perform such configuration 286
Source (05) Cell parameters
inconsistency 288
Source (10) Unknown Abis PCM 293
Source (23) Too many signaling
timeslots 297
Source (25) Out of sequence
message 298
Source (34) The BTS has not
acknowledged the power
consign request 302
Source (43) Maximum number of
joker TS 309
Source (6) Data inconsistency 290
Source (63) Dynamic Abis feature
not supported 316
Source (64) Inconsistent number
of joker DS0 317
Source (7) Value out of range 291
Source (8) TEI not present 292
1060 Abis event reporting a transient
default 358
Source (12582924) Frequency
collision on FH bus: eDRX 359
Source (12582935) FACCH
congestion: eDRX 360
Source (12583171) Restart
requested by the BCF: eDRX 360
Source (12583175) Restart due to
hardware watchdog: eDRX 361
Source (12583176) Restart due to
double bus fault: eDRX 362
Source (12583186) BCCH config
dump: eDRX 362
Source (12583202) SACCH config
dump: eDRX 363
Source (12583218) L1M config
dump: eDRX 363
Source (12583219) RSL anomaly:
eDRX 363
Source (12779522) Unknown
message: CMCF phase 1 355
Source (12779556) Restart
requested by the active board:
CMCF phase 1 356

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

762

Source (12779558) Restart due


to hardware watchdog: CMCF
phase 1 357
Source (12779559) Restart due to
double bus fault: CMCF phase
1 357
Source (12779560) Reset for new
Lapd parameters: CMCF Ph1 357
Source (12779571) Board reset
asked by OMC: CMCF phase 1 356
Source (12845058) Unknown
message: CMCF phase 2 355
Source (12845092) Restart
requested by the active board:
CMCF phase 2 356
Source (12845094) Restart due
to hardware watchdog: CMCF
phase 2 357
Source (12845095) Restart due to
double bus fault: CMCF phase
2 357
Source (12845096) Reset for new
Lapd parameters CMCF Ph2 357
Source (12845107) Board reset
asked by OMC: CMCF phase 2 356
Source (12910577) ABIS PCM
statistics: CMCF PH2 358
Source (12976140) Frequency
collision on FH bus: DRX-ND3 359
Source (12976151) FACCH
congestion: DRX ND3 360
Source (12976387) Restart
requested by the BCF:
DRX-ND3 360
Source (12976389) Restart
due to hardware watchdog:
DRX_ND3 361
Source (12976390) Restart due to
double bus fault: DRX_ND3 362
Source (12976402) BCCH config
dump: DRX_ND3 362
Source (12976418) SACCH config
dump: DRX_ND3 363
Source (12976434) L1M config
dump: DRX_ND3 363
Source (12976435) RSL anomaly:
DRX_ND3 363
Source (15204611) Restart
requested by the BCF: eDRX2 360

Source (4259878) Restart due to


hardware watchdog: CSWM 358
Source (4259879) Restart due to
double bus fault: CSWM 359
Source (9437196) Frequency
collision on FH bus: DRX 359
Source (9437207) FACCH
congestion: DRX 360
Source (9437443) Restart
requested by the BCF: DRX 360
Source (9437447) Restart due to
hardware watchdog: DRX 361
Source (9437448) Restart due to
double bus fault: DRX 362
Source (9437458) BCCH config
dump: DRX 362
Source (9437474) SACCH config
dump: DRX 363
Source (9437490) L1M config
dump: DRX 363
Source (9437491) RSL anomaly:
DRX 363
Source (9502722) Unknown
message: CMCF 355
Source (9502756) Restart
requested by the active board:
CMCF 356
Source (9502758) Restart due to
hardware watchdog: CMCF 357
Source (9502759) Restart due to
double bus fault: CMCF 357
Source (9502760) Reset for new
Lapd parameters: CMCF 357
Source (9502771) Board reset
asked by OMC: CMCF 356
Source (9568241) ABIS PCM
statistics: CMCF 358
1063 TRX allocation for a TDMA 386
1067 Abis event reporting a
hardware fault 387
(H)(e)PA 667
Source (12582913) RX fault:
eDRX 585
Source (12582918) BBFILTER
ASIC fault: eDRX 576
Source (12582921) Self test failed:
eDRX 609
Source (12582922) Major fault on
TX: eDRX 597

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

763

Source (12582934) DRX link:


eDRX 591
Source (12582944) The TX has
not ack the power consign
request: eDRX 580
Source (12582945) PA DRX
control loop fault: eDRX 602
Source (12582946) DRX reset by
BCF after message non ack.:
eDRX 602
Source (12582947) DRX link NOK
after reset requested by BSC:
eDRX 596
Source (12583184) BCCH first
config failed: eDRX 589
Source (12583185) BCCH second
config failed: eDRX 590
Source (12583200) SACCH first
config failed: eDRX 607
Source (12583201) SACCH
second config failed: eDRX 608
Source (12583216) L1M first
config failed: eDRX 589
Source (12583217) L1M second
config failed: eDRX 597
Source (12648449 ) Hardware:
ePA 652
Source (12648450) DRX and PA
connection: ePA 658
Source (12648451) High temp:
ePA 663
Source (12648454) PA_PSDW:
ePA 671
Source (12713985) Hardware:
(H)(e)PA 652
Source (12713986) DRX and PA
connection: HePA 658
Source (12713987) High temp:
HePA 663
Source (12713988) High current:
HePA 667
Source (12713990) PA_PSDW:
HePA 671
Source (12779529) MCF_MCF:
CMCF phase 1 507
Source (12779538) CMCF ACT
DUPLEX INHIBITED: CMCF
phase 1 512
Source (12779539) CMCF ACT
ICST: CMCF phase 1 515

Source (12779540) Duplex


inhibited: feature not supported
on CMCF phase 1: CMCF
phase 1 517
Source (12845050) Slave
downloading error: CMCF
phase 1 510
Source (12845065) MCF_MCF:
CMCF phase 2 507
Source (12845074) CMCF ACT
DUPLEX INHIBITED: CMCF
phase 2 512
Source (12845075) CMCF ACT
ICST: CMCF phase 2 515
Source (12910586) Slave
downloading error: CMCF
phase 2 510
Source (12976129) RX fault:
DRX-ND3 585
Source (12976134) BBFILTER
ASIC fault: DRX-ND3 576
Source (12976137) Self test failed:
DRX-ND3 609
Source (12976138) Major fault on
TX: DRX-ND3 597
Source (12976150) DRX link:
DRX-ND3 591
Source (12976160) The TX has
not ack the power consign
request: DRX-ND3 580
Source (12976161) PA DRX
control loop fault: DRX-ND3 602
Source (12976162) DRX reset by
BCF after message non ack.:
DRX-ND3 602
Source (12976163) DRX link NOK
after reset requested by BSC:
DRX-ND3 596
Source (12976400) BCCH first
config failed: DRX-ND3 589
Source (12976401) BCCH second
config failed: DRX-ND3 590
Source (12976416) SACCH first
config failed: DRX-ND3 607
Source (12976417) SACCH
second config failed: DRX-ND3 608
Source (12976432) L1M first
config failed: DRX-ND3 589
Source (12976433) L1M second
config failed: DRX-ND3 597

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

764

Source (3342340) SYNO clock


not locked on the network: BTS
synchronization 441
Source (3342341) Synchro not
locked because OCVXO is KO:
BTS synchronization 448
Source (3735553) Alarm: Not
protected alarm 646
Source (5242881) AC fault:
Rectifier 48V 682
Source (5242882) DC fault:
Rectifier 48V 686
Source (5242883) Over
temperature: Rectifier 48V 688
Source (5242885) PCU protective:
Rectifier 48V 693
Source (5308417) Volt: Converter
F 624
Source (5570561) LNA fault:
Combiner duplexer LNA or
combiner H2 LNA 520
Source (5636097) VSWR level
1: Combiner duplexer vswr or
combiner h2 vswr 524
Source (5636098) VSWR level
2: Combiner duplexer vswr or
combiner h2 vswr 524
Source (5636099) VSWR level
3: Combiner duplexer vswr or
combiner h2 vswr 525
Source (5767169) Main breaker:
Distribution system 557
Source (5898241) Door contact
detection: Door contact 479
Source (6160385) Lightning
protection fault: Lightning
Protection 643
Source (6488065) PCM: PCM 652
Source (6815745) Hardware: PA 652
Source (6815746) DRX and PA
connection: PA 658
Source (6815747) High temp: PA 663
Source (6815748) High current:
PA 667
Source (6815750) PA_PSDW: PA 671
Source (6815751) VSWR fault
detected by PA: PA 675
Source (6881281) Software
detection: DRX main reception
chain 565

Source (6881281) Software


detection: DRX-ND3 main
reception chain 565
Source (6946817) Software
detection: DRX diversity
reception chain 560
Source (6946817) Software
detection: DRX-ND3 diversity
reception chain 560
Source (7274497) External alarm 621
Source (7864321) Dirty filter:
dacsCooler 549
Source (7864322) DACS failed:
dacsCooler 551
Source (9437185) RX fault: DRX 585
Source (9437190) BBFILTER
ASIC fault: DRX 576
Source (9437193) Self test failed:
DRX 609
Source (9437194) Major fault on
TX: DRX 597
Source (9437206) DRX link: DRX 591
Source (9437214) Abis satellite
not supported DRX: DRX 569
Source (9437216) The TX has not
ack the power consign request:
DRX 580
Source (9437217) PA DRX control
loop fault: DRX 602
Source (9437218) DRX reset by
BCF after message non ack.:
DRX 602
Source (9437219) DRX link NOK
after reset requested by BSC:
DRX 596
Source (9437456) BCCH first
config failed: DRX 589
Source (9437457) BCCH second
config failed: DRX 590
Source (9437472) SACCH first
config failed: DRX 607
Source (9437473) SACCH second
config failed: DRX 608
Source (9437488) L1M first config
failed: DRX 589
Source (9437489) L1M second
config failed: DRX 597
Source (9502729) MCF_MCF:
CMCF 507

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

765

Source (9568250) Slave


downloading error: CMCF 510
Source (9568257) Major fault:
CPCMI 541
Source (9633786) Slave
downloading error: CPCMI 541
Source (9633793) Major: RECAL 676
Source (9699322) Slave
downloading error: RECAL 679
Source (9699329) Over current:
Rx splitter M 649
Source (9764865) Over current:
Rx splitter D 646
1070 TRX synchronization failure 712
1073 Attempt of download failure on
a GSM entity 712
Source (09) No response to load
message 718
Source (10) Received LOAD INIT
NACK 718
Source (11) Received LOAD DATA
NACK 718
Source (12) Received LOAD END
NACK 718
Source (13) Received LOAD
READY NACK 718
1077 Update of the activation status
of a site
1077 Update of the activation
status of a site 719
1080 Access fault 720
1213 Secured loop unavailable 721
1214 Secured loop problem 722
1258 No BTS response on
preprocessing configuration 722
1259 Negative acknowledgement on
preprocessing command 724
1265 Blockage of radio channel(s) in
busy state 725
1266 Blockage of radio channel(s) in
free state 726
1268 NO RESPONSE TO A SACCH
FILLING (SYS 5, 6, 5bis, 5ter or
meas_info) 727
1500 Measurement received on
an unknown frequency of
neighboring cell 728
1505 No response to BCCH info
(SYS 1, 2, 3, 4, 2 bis, 7, 8, 2 ter,
13) 729

1506 No distribution available for a


cell 730
1508 Data service impact (SYS 13
size exceeded) 731
30034 Background downloaded
action is aborted
Source (30315) BSC restart
occurred 732
Source (30316) Core process is
nullex 732
Source (9568257) Major fault: CPCMI
1067 Abis event reporting a
hardware fault
Source (9568257) Major fault:
CPCMI 541

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

766

Global System for Mobile Communications (GSM)


Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing
411-9001-103 18.06 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.

Global System for Mobile Communications (GSM)

Nortel GSM BTS S8000/S8002/S8003/S8006 Fault Clearing


Release: V18.0 PC2
Publication: 411-9001-103
Document revision: 18.06
Document release date: 20 January 2010
Copyright 1999-2009 Nortel Networks. All Rights Reserved.
While the information in this document is believed to be accurate and reliable, except as otherwise expressly agreed to in writing
NORTEL PROVIDES THIS DOCUMENT "AS IS" WITHOUT WARRANTY OR CONDITION OF ANY KIND, EITHER EXPRESS
OR IMPLIED. The information and/or products described in this document are subject to change without notice.

Nortel, Nortel Networks, the Nortel logo, and the Globemark are trademarks of Nortel Networks.
Sourced in Canada, France, and the United States of America.
LEGAL NOTICE
While the information in this document is believed to be accurate and reliable, except as otherwise expressly agreed to in writing
NORTEL PROVIDES THIS DOCUMENT "AS IS" WITHOUT WARRANTY OR CONDITION OF ANY KIND, EITHER EXPRESS
OR IMPLIED. The information and/or products described in this document are subject to change without notice.
Nortel, the Nortel logo, the Globemark, S2000 and S8000 are trademarks of Nortel Networks.
All other trademarks are the property of their respective owners.
_ 17+ 18+
All other trademarks are the property of their respective owners.

To provide feedback or to report a problem in this document, go to www.nortel.com/documentfeedback.


www.nortel.com