Documente Academic
Documente Profesional
Documente Cultură
OXYSource
Contact Information:
Features:
Can operate from a standard factory Up to 90% cost savings when compared to
compressed air supply
tradition methods of supply
Benefits:
Prevents wasted gas
OXYSource eliminates return of unused gas
when swapping cylinders and boil-off from liquid
supplies
Typical capital pay-back within 12-24 months
Energy savings
Lowest air consumption provides greatest
energy efficiency and lowest unit gas cost
Maximum up time
Gas on demand means that oxygen is available
instantly, when required. Preventing downtime
due to delivery issues
Convenient and safe
The easy to use system is simple to install,
requires minimal maintenance and eliminates
the safety hazards associated with traditional
oxygen gas supplies
Product Selection
Performance data is based on 7 bar g (100 psi g) air inlet pressure and 20C - 30C (66F - 86F)ambient temperature. Consult Parker for performance under other specific conditions.
Oxygen Flow Rate m3/hr vs Purity (Oxygen Content)
90%
92%
93%
94%
95%
Feed Air
Receiver (litres)
Oxygen Vessel
(litres)
OXYSource O2-1
N/A
N/A
0.8
0.7
0.7
30
30
OXYSource O2-2
N/A
N/A
1.7
1.7
1.6
60
60
OXYSource O2-3
N/A
N/A
2.5
2.4
2.3
90
90
OXYSource O2-4
N/A
N/A
3.5
3.4
3.2
90
90
OXYSource O2-5
4.9
4.7
4.6
4.4
4.2
150
150
OXYSource O2-6
7.3
7.0
6.8
6.5
6.2
150
150
OXYSource O2-8
8.6
8.2
8.0
7.6
7.3
320
320
OXYSource O2-10
10.7
10.3
10.0
9.5
9.1
320
320
OXYSource O2-12
12.8
12.4
12.0
11.4
10.9
320
320
OXYSource O2-15
15.5
14.9
14.5
13.8
13.2
320
320
OXYSource O2-17
18.4
17.7
17.2
16.4
15.6
320
320
OXYSource O2-20
21.4
20.6
20.0
19.1
18.2
750
750
OXYSource O2-22
23.5
22.7
22.0
21.0
20.0
750
750
OXYSource O2-27
29.0
27.8
27.0
25.7
24.6
1000
1000
OXYSource O2-30
33.2
31.9
31.0
29.5
28.2
1000
1000
OXYSource O2-50
51.4
49.4
48.0
45.7
43.4
1500
1500
OXYSource O2-55
58.9
56.7
55.0
52.4
50.0
2000
2000
OXYSource O2-75
80.3
77.3
75.0
71.4
68.2
3000
2000
OXYSource O2-80
85.6
82.4
80.0
76.2
72.7
2000
2000
Model
m reference standard = 15C, 981 millibar(a), 0% relative water vapour pressure. Flow rates +/- 5%
3
Inlet Parameters
Dimensions
H x W x D (cm)
Weight
kg
Shipping Dimensions
H x W x D (cm)
OXYSource O2-1
150 x 60 x 50
75
175 x 80 x 70
OXYSource O2-2
150 x 60 x 50
115
175 x 80 x 70
OXYSource O2-3
150 x 60 x 50
145
175 x 80 x 70
OXYSource O2-4
200 x 60 x 50
200
225 x 80 x 70
10C to 40C
OXYSource O2-5
186 x 70 x 70
250
246 x 90 x 90
IP22
OXYSource O2-6
186 x 70 x 70
250
246 x 90 x 90
OXYSource O2-8
221 x 70 x 70
370
246 x 90 x 90
OXYSource O2-10
230 x 75 x 90
500
255 x 95 x 110
OXYSource O2-12
230 x 75 x 90
500
255 x 95 x 110
OXYSource O2-15
230 x 75 x 110
700
255 x 95 x 255
100 Watts
OXYSource O2-17
230 x 75 x 110
700
255 x 95 x 130
Maximum of 10 Amps
Unit must be earthed
OXYSource O2-20
230 x 75 x 110
700
255 x 95 x 130
OXYSource O2-22
230 x 90 x 130
1100
OXYSource O2-27
1800
OXYSource O2-30
1800
OXYSource O2-50
2000
OXYSource O2-55
2000
3000
3000
7-8 barg
40C
Environmental Parameters
Ambient Temperature
IP Rating
Electrical Parameters
Supply Voltage
Power
Fuse
Port Connections
Model
Model
Oxygen Outlet
G3/4
G3/8
G1
G /2
OXYSource O2-75
G1 /2
G1
OXYSource O2-80
For more information please contact your local sales office or visit www.parker.com
Parker has a continuous policy of product development and although the company reserves the right to changes specifications, it attempts to keep customers informed of any alterations.
2014 Parker Hannifin Corporation. All rights reserved.