Documente Academic
Documente Profesional
Documente Cultură
0
Service & Operating
ProCash Systems
User Guide
All rights, including rights of translation, reproduction by printing, copying or similar methods, even of parts are
reserved. Offenders will be liable for damages. All rights, including rights created by patent grant or registration
of a utility model or design, are reserved. Right of technical modifications reserved.
Copyright (c) Wincor Nixdorf GmbH & Co. KG 1999, 2000
Contents
Contents
Contents.............................................................................................................. i
Introduction ....................................................................................................... 1
Product definition............................................................................................................ 1
Target group .................................................................................................................... 2
Notational conventions................................................................................................... 2
Fundamentals .................................................................................................... 3
User guidance on the operator panel............................................................................ 3
Screen layout on the operator panel............................................................................... 3
Function selection ........................................................................................................... 4
Meaning of function keys ................................................................................................ 5
User guidance on the graphic operator panel ............................................................. 8
Screen layout on the graphic operator panel.................................................................. 8
Function selection ......................................................................................................... 10
Meaning of function keys .............................................................................................. 10
User guidance on the customer display and PIN pad ............................................... 14
Screen layout on the customer display......................................................................... 14
Function selection ......................................................................................................... 15
Meaning of function keys .............................................................................................. 16
Standby mode................................................................................................................ 20
Starting and user identification ................................................................................... 22
Synchronizing SOP and customer application .......................................................... 24
Switching screens......................................................................................................... 26
Exiting SOP.................................................................................................................... 28
SOP functions.................................................................................................. 37
Self service device ........................................................................................................ 37
Show status overview ................................................................................................... 37
Restart self service device ............................................................................................ 40
Switch off self service device ........................................................................................ 41
Contents
Date / Time.................................................................................................................... 42
Copy files ...................................................................................................................... 43
Export journal ................................................................................................................ 46
Export SOP journal ....................................................................................................... 48
Start traces.................................................................................................................... 51
Stop traces .................................................................................................................... 52
Export traces ................................................................................................................. 53
Export diagnostics......................................................................................................... 56
Adjust bell...................................................................................................................... 59
ID Card Unit (IDCU) ....................................................................................................... 60
Show IDCU status......................................................................................................... 60
Remove retained ID cards ............................................................................................ 61
Remove jammed ID cards ............................................................................................ 62
Load CIM86 key............................................................................................................ 63
Cash Units...................................................................................................................... 66
Show cash units status ................................................................................................. 66
Basic steps to exchange cash units.............................................................................. 69
Default exchange .......................................................................................................... 76
Complete exchange ...................................................................................................... 78
Refill cash units ............................................................................................................. 79
Initialize cash units ........................................................................................................ 81
Setup reference value................................................................................................... 84
Release cash units........................................................................................................ 87
Set cash unit counters .................................................................................................. 90
Add counters ................................................................................................................. 92
Cash Dispenser Module (CDM).................................................................................... 94
Show cash dispenser status ......................................................................................... 94
Check transport............................................................................................................. 95
Remove customer money ............................................................................................. 99
Move shutter ............................................................................................................... 102
Update cash unit table ................................................................................................ 104
Update default table.................................................................................................... 108
Select denomination algorithm.................................................................................... 112
Select max. no. of retracts .......................................................................................... 114
Test dispensing ........................................................................................................... 116
HW device status ........................................................................................................ 117
HW cash unit status .................................................................................................... 118
Display Version ........................................................................................................... 119
Coin-Out module ......................................................................................................... 120
Show Coin-Out Status ................................................................................................ 120
Refill Coin-Out............................................................................................................. 122
Empty Coin-Out........................................................................................................... 124
Initialize Coin-Out........................................................................................................ 127
Test Dispense ............................................................................................................. 130
ii
Contents
iii
Contents
iv
Introduction
Introduction
Product definition
The software product ProCash/SOP has been designed to guarantee a user-friendly
service and operating of the Wincor Nixdorf self service devices by branch office staff.
SOP stands for Service & Operating.
The SOP functions are used:
To ensure that the self service device operates properly (e.g. testing the current
device status in order to avoid malfunctions)
To service a CSC (e.g. refilling cash or removing retained ID cards)
To install and administer the self service device
Many functions can be performed in parallel to the customer application, thus achieving a
high degree of system availability for customers.
Clear and configurable function menus allow even inexperienced staff members to select
the required function quickly. Security mechanisms control the functions which are made
available to each user.
SOP can be handled via the operator panel or via the customer display with the
associated function keys and the PIN pad, depending on how the self service device has
been configured.
Comprehensive help texts and system messages support the user. These texts appear in
the language that was defined during installation.
Introduction
Target group
This User Guide is a reference manual for branch staff who have been entrusted with
operating and servicing self service devices.
It is assumed that the users know how to handle the self service device. Training courses
are offered from Wincor Nixdorf for this.
Notational conventions
Special information
Fundamentals
Fundamentals
User guidance on the operator panel
The following chapter describes the handling of SOP via the operator panel (up to model
year 1998). Nearly all functions can be performed on the operator panel. Some functions,
however, such as "Initialize EPP via ID card" can only be performed via the customer
display. In these cases messages shown at the operator panel request a user to turn to
the customer display.
Line 6:
The active function keys are displayed in the last line. The keys displayed from left to
right correspond to the actual arrangement of function keys from top to bottom. The first
key can be allocated to different functions. Any inactive key can be grayed.
Fundamentals
= Cancel
= Exit SOP
= Go back one menu level
= Change to "Note count" input mode
= Switch to "Amount" input mode
= Show additonal information about an error
= Show technical information about an error
F2
F3
F4
OK
= Confirm
The input field for menu selection, indicated by a flashing cursor, is also here.
Function selection
The function is selected by entering the digit indicated
next to the function.
If the SOP configuration allows a direct selection of
functions, functions which are not indicated on the screen
can be selected "blindly" via the function code. In this
case the function code may have two digits and must be
confirmed with "OK".
Fundamentals
Cancel/Exit/Back/Switch
Cancel: This key cancels the selected function in SOP. It
is also used to negate questions checking whether you
really want to do something.
Exit: Pressing this key on the top menu level terminates
SOP.
Back: Pressing this key on a SOP menu returns control
to the previous menu level.
Switch: When entering cash values, the input can either
be definded as an amount or as the number of notes
(note count). In this case the function key is used to
switch from one input mode to the other.
If F1 key is activated, the respective function text for this
key is displayed in the last line.
Scrolling backward
If a SOP menu or any other information that is displayed
extends over more than one page, then this function key
is used to scroll backward page by page.
When processing on a line-by-line basis within a function,
it moves the cursor up one line.
If the mask includes several input fields, this key is used
to position the cursor back to the previous input field
provided this is allowed.
<< indicates that the scroll back key has been activated.
Fundamentals
Scrolling forward
If a SOP menu or any other information that is displayed
extends over more than one page, then this function key
is used to scroll forward page by page.
When processing on a line-by-line basis within a function,
it moves the cursor down one line.
If the mask includes several input fields, this key is used
to position the cursor forward to the next input field
provided this is allowed.
>> indicates that the scroll forward key has been
activated.
Confirm
This key is used to confirm data inputs , error or
informational messages and to affirm questions checking
whether you really want to do something.
Fundamentals
Correction
If the cursor is placed in an input field, the correction key
is allowed to be pressed. It deletes the character that has
been entered last on the operator panel.
<,>+<1>
<,>+<3>
<,>+<5>
"B":
"D":
"F":
<,>+<2>
<,>+<4>
<,>+<6>
The "Comma" key must be pressed once only and be released before entering
a digit.
Fundamentals
Fundamentals
= Cancel
= Exit SOP
= Go back one menu level
= Switch to "Note count" input mode
= Switch to "Amount" input mode
= Show additional information about an error
= Show technical information about an error
F2
F3
F4
OK
= Confirm
The "CAN" key and the "OK" key corrspond to the F1 and F4 key as far as their function
is concerned.
The input field for menu selection, indicated by a flashing cursor, is also here.
Fundamentals
Function selection
The function is selected by entering the digit
indicated next to the function.
If the SOP configuration allows a direct selection
of functions, functions which are not indicated on
the screen can be selected "blindly" via a function
code. In this case the function code may have two
digits and must be confirmed with "OK".
The functions can also be selected via the keys
left of the display.
Cancel/Exit/Back/Switch
Cancel: This key cancels the selected function in
SOP. It is also used to negate questions checking
whether you really want to do something.
Exit: Pressing this key on the top menu level
terminates SOP.
Back: Pressing this key on a SOP menu returns
control to the previous menu level.
Switch: When entering cash values, the input can
either be defined as an amount or as the number
of notes (note count). In this case this function key
is used to switch from one input mode to the
other.
If the cancel key is activated, the respective
function text for this key is displayed in the last
line.
10
Fundamentals
Scrolling backward
If a SOP menu or any other information that is
displayed extends over more than one page, then
this function key is used to scroll backward page
by page.
When processing on a line-by-line basis within a
function, it moves the cursor up one line.
If the mask includes several input fields, this key
is used to position the cursor back to the previous
input field provided this is allowed.
<< indicates that the scroll back key has been
activated.
Scrolling forward
If a SOP menu or any other information that is
displayed extends over more than one page, then
this function key is used to scroll forward page by
page.
When processing on a line-by-line basis within a
function, it moves the cursor down one line.
If the mask includes several input fields, this key
is used to position the cursor forward to the next
input field provided this is allowed.
<< indicates that the scroll forward key has been
activated.
11
Fundamentals
Confirm
This key is used to confirm data inputs, error or
informational messages and to affirm questions
checking whether you really want to do
something.
Correction
If the cursor is placed in an input field, the
correction key is allowed to be pressed. It deletes
the character that has been entered last on the
operator panel.
12
Fundamentals
<,>+<1>
<,>+<3>
<,>+<5>
"B":
"D":
"F":
<,>+<2>
<,>+<4>
<,>+<6>
The "Comma" key must be pressed once only and be released before entering
a digit.
13
Fundamentals
14
Fundamentals
situation, some keys may have been deactivated. In this case, the labeling and the arrow
on the function key are grayed.
Function keys on the left (3):
The functions allocated to the function keys on the left depend on the current menu or
function. They can, for example, be used to select individual functions. Keys may have
been deactivated here, too, i.e. they are grayed.
Function window (4):
All outputs and all input fields of the selected functions appear in the function window.
Message box (5):
Messages concerning the selected function and the handling of the device, as well as
error messages, appear in this box.
Function selection
The functions on the customer screen can be
selected in two ways:
Pressing the softkeys on the left side of the
function menu. If devices have a touchscreen,
the user can directly press the button labeled
with the corresponding function.
Entering the function number via PIN pad and confirming with "OK". This way of
function selection is optional and can be activated via a configuration parameter.
It is also possible to operate SOP via a connected PC keyboard instead of a PIN pad. If
this option has been configured, the labeling of the PC key which has to be pressed is
displayed on the button.
The navigation within the menu is done via the function keys on the right and the scrolling
backward/forward keys. The cancel key is used to return to the previous menu.
15
Fundamentals
Cancel/Exit/Back/Switch
Cancel: This key cancels the selected function in
SOP. It is also used to negate questions checking
whether you really want to do something.
Exit: Pressing this key on the top menu level
terminates SOP.
Back: Pressing this key on a SOP menu returns
control to the previous menu level.
Switch: When entering cash values, the input can
either be defined as an amount or as the number of
notes (note count). In this case, the function key is
used to switch from one input mode to the other.
16
Fundamentals
Scrolling backward
If a SOP menu or any other information that is
displayed extends over more than one page, then
this function key is used to scroll backward page by
page.
When processing on a line-by-line basis within a
function, it moves the cursor up one line.
If the mask includes several input fields, this key is
used to scroll forward to the next input fieldprovided this is allowed.
Note:
If the PIN pad is used, the key that is labeled
Correct has to be pressed to scroll back.The key
can be allocated with correction or scrolling
backward, depending on the configuration.
Scrolling forward
If a SOP menu or any other informaton that is
displayed extends over more than one page, then
this function key is used to scroll forward page by
page.
When processing on a line-by-line basis within a
function, it moves the cursor down one line.
If the mask includes several input fields, this key is
used to scroll forward to the next input field
provided this is allowed.
Note:
If scrolling back was deconfigured for the key
labeled correct, scrolling forward is deconfigured,
too.
17
Fundamentals
Confirm
This key is used to confirm data inputs, error or
informational messages and to affirm questions
checking whether you really want to do something.
Correction
If the cursor is placed in an input field, the
correction key is also allowed to be pressed. It
deletes the characters entered.
Note:
Pressing the key labeled correct can also result in
correction. The key can be allocated with correction
or scrolling back, depending on the configuration.
18
Fundamentals
<,>+<1>
<,>+<3>
<,>+<5>
"B":
"D":
"F":
<,>+<2>
<,>+<4>
<,>+<6>
To enter hexadecimal letters press the Comma key first and then a numeric key.
The Comma key must be pressed once only and be released before entering
a digit.
19
Standby mode
Fundamentals
Standby mode
In standby mode a message will be displayed
on the operator panel indicating the activation
of SOP.
At the same time the other accesses to SOP
have been activated, too:
SOP button
Open device door
SYNC Service
Any reasons for the self service device being out of service will be displayed on the
operator panel, parallel to the customer application.
Error / Warning
Device
Error class/number
Error text
Error text
Action to be taken
Reasons for the self service device being out of service include:
20
Hardware errors
Cash on transport paths
Maximum number of retracts reached
Reject bin of retract/reject cash unit full
Fundamentals
Standby mode
Warnings include
Cassette "s" low
Reject bin of retract/reject cash unit nearly full
If there is more than one out-of-service or warning information, the user may switch from
one to the other by means of the scrolling keys (F2/F3). With the INFO key (F1) it is
possible to display additional information on each error. Within this detail view a technical
error description is available, too (TECH key F1).
The out-of-service and warning information is displayed on the customer screen after
activating the SOP via SOP switch or changing the screen from operator panel to
customer screen.
21
Fundamentals
If no password has been entered for the SOP user in the user table, the password entry
is skipped. The user identification process is finished as soon as the login has been
entered. If no input is made within a defined time, the user identification process is
canceled automatically and the standby mode is activated.
If the "Language selection option has
been activated for a user, he or she is
asked to specify the language to be used
for SOP. German and English are
supported.
Then the user-dependent SOP start menu
is displayed.
22
Fundamentals
23
Fundamentals
Synchronization procedure:
When a function requiring synchronization
with the application is first selected, the
user is asked whether customer operations
are to be locked (whether this screen
appears is optional).
Synchronization starts if you select OK.
"Cancel" returns control to the previous
menu level without synchronization.
24
Fundamentals
Failure to synchronize
Synchronization is canceled if SOP does
not receive permission to access the self
service device within the specified time.
"OK starts the synchronization anew,
"Cancel returns control to the previous
menu.
25
Switching screens
Fundamentals
Switching screens
On any menu level it is possible to switch screens both from the operator panel and from
the customer display by entering 0. It is not possible to switch screens within a function.
Functions which only run on the customer display
Some functions can only be started from the
customer display. A message is is shown on
the operator panel if such a function is
selected.
Control returns to the menu level when this
message has been confirmed. From here you
can switch screens by entering a 0".
Access control
If the access control option has been set and you switch from one screen to another, then
the access control function is activated. You have to identify yourself again.
Panel Protection Door
The Panel Protection Door is opened, if applicable, when SOP switches to the customer
display, and is closed on exiting SOP or on switching to the operator panel.
26
Fundamentals
Switching screens
When you have identified yourself again at the customer display, the menu appears
from which the switch was initiated.
Procedure on switching from the customer display to the operator panel:
Enter "0" to select function and press "OK".
The Panel Protection Door closes.
When you have identified yourself again at the operator panel, the menu appears from
which the switch was initiated. The self service device remains locked for the
customer application until you exit SOP.
27
Exiting SOP
Fundamentals
Exiting SOP
When the SOP functions have been completed you have to exit SOP. This is necessary
in particular when the SOP functions incorporate requests for the self service device.
Only in this way is the self service device released again for the customer application.
There are two ways of exiting SOP:
Explicitly by means of the Cancel key on the top menu level. Here the key is labeled
"END" oder "Exit SOP.
Implicitly via SOP`s time monitoring facility.
Exiting with the "END" or "Exit SOP key
The normal way to exit SOP is to press the Cancel key to return to the previous menu
level until the top level has been reached. Pressing the Cancel key there again (labeled
"END" or "Exit SOP) activates standby mode.
Any monitored doors that are still open
have to be closed.
The safe door has to be closed first.
28
Fundamentals
Exiting SOP
29
Function view
30
Function view
Functional view
Activity characteristics
Trouble shooting
Installation &
Administration
Cash
Dispenser
Printer
Deposit
EPP
Functions
...
Component
Component view
IDCU
CSC
The view chosen defines the structure of the menu that is shown to the user when he
or she selects SOP (refer to "Component view" section).
In event of problems (out-of-service reasons / warnings), the trouble shooting view
is presented to all users, i.e. each user gets a menu with trouble-shooting functions.
31
Component view
Component view
In the component view the functions on the menu are arranged by hardware components.
This makes it possible for expert users in particular to arrange functions clearly and select
them quickly.
The first menu level of the component view shows all installed devices. When a device
has been selected all functions belonging to it are shown on the second menu level. Each
executable function can be called via two menu levels.
In addition the function groups Administration, Diagnostics and Individual functions can
be reached via the first menu level.
The table on the next pages give an overview of the functions provided by each
component.
32
CSC
Component view
Coin-Out
Show Status Overview
CSC Restart
CSC Shutdown
Export Journal
Export SOP-Journal
Start Traces
Stop Traces
Export Traces
Export Diagnostics
Copy Files
Set Date & Time
Adjust Bell
ID Card Unit
Show IDCU Status
Remove Retained Cards
Remove Stuck Card
Load CIM86-Key
Cash Units
Show Cash Units Status
Default Exchange
Complete Exchange
Refill Cash Units
Initialise Cash Units
Set-up Reference Value
Release Cash Units
Set Cash Unit Counters
Add Cash Unit Counters
Cash Dispenser
Show Cash Dispenser Status
Check Transport
Remove Customer Money
Move Shutter
Update Cash Unit Table
Update Default Table
Select Denomination Algorithm
Select Max. No. of Retracts
Test Dispense
Show Hardware Device Status
Show Hardware Cash Units Status
Display Version
Encrypting PIN-Pad
General Functions
Show EPP Status
Configure EPP
Default Procedure
Initialise EPP
Update Key Table
Update EPP individually
Update EPP sequentially
IBM Procedure
Initialise EPP
Enter Master Key
Enter Initial Master Key
Enter Key Exchange Key
Via Admi-System
Initialise EPP from ID Card
Load EPP
33
Component view
Diagnostics
Printer
Show Diagnostics
Set Filter Options
Deposit
34
After confirmation of the error text and successful login, the so-called trouble shooting
menu is displayed. It offers, if possible, at least one function to repair an error.
Entering the assigned number starts the
problem handling function. More details on
this are described in the relevant chapter.
"Cancel" returns control to the top menu level.
If there is only one function which can be used
to repair an error, it will be executed
immediately after starting the SOP (i.e. no
trouble shooting menu is displayed). Then the
menu configured for the user is displayed.
35
If the user is not authorized to call the available function, the following message is
displayed after confirmation:
If the SOP trouble shooting functions are
completed successfully, the corresponding
errors and warnings are deleted from the list
of out-of-service-reasons. The remaining
problems will be displayed again in standby
mode after exiting SOP.
36
SOP functions
Self service device
Show status overview
The "Show status overview" function is used to call up information on the status of the
CSC. The statuses that are displayed contain all information that is needed to carry out
preventive maintenance for the CSC and to react in good time to pending service
requirements (e.g. to exchange cash units).
The amount of information provided depends on the configuration of the CSC. Only
information on devices that have been installed is displayed.
The status overview can contain the following information:
The status overview can be extended by an external application (User Exit). The
sequence in which the information is displayed is configurable. The sequence shown
here corresponds to the standard setting.
37
Procedure:
Select "Show status overview" function.
A message appears indicating that the
status test is in progress. Since the status
of all connected devices is tested, the
inquiry may take a while.
38
CDM
CDM status
Retract status
Transport status
Shutter status
EPP
EPP status
PIN pad status
Scanner
Scanner status
Number of retracted documents
Document status
Printer
Printer status
Number of retracted documents
Document jammed / Paper jam
Paper status
Toner status
Chassis doors
Open / Closed
39
Procedure:
Select the "Restart self service device" function.
Synchronize with customer application if necessary.
"Cancel" terminates the function and returns control to the previous menu.
40
Procedure:
Select the "Switch off self service device" function.
Synchronize with the customer application if necessary.
"Cancel" terminates the function and returns control to the previous menu.
41
Date / Time
Date / Time
The "Date / Time" function is used to set the system time of the self service device.
Procedure:
Select "Date / Time" function.
Enter new date.
Enter new time.
"OK" confirms the entry and positions to
the next field. If "OK" is pressed in the last
field (minutes), date and time entered are
set.
"OK" terminates the function and control is
returned to the previous menu.
During the entry the scrolling forward/backward keys can be used to position the cursor
from one field to the other.
A plausibility check is done for the date and time entered and, if necessary, the user is
given an error message ("Wrong date" or "Wrong time").
The two-digit numbers of the year are entered as follows: Entries > 90 199x, entries <
90 2xxx.
42
Copy files
Copy files
The function "Copy files" is used to copy files. The files to be copied are specified in the
command file sopcopy.txt (structure is given in appendix A). The source and destination
can be a diskette (drive A:) or the hard disk (drive C:).
Procedure:
Select the "Copy files" function.
Synchronize with the customer application
if necessary.
To access the diskette drive, a device door
has to be opened.
Then you are prompted to insert the
diskette into drive A:.
"Cancel" terminates the function and returns control to the previous menu.
When the diskette has been entered, it is checked whether the user is authorized to
copy the files stored in the command file. If the user is not authorized, the function is
aborted and an error message is given.
The further function flow depends on where the command file is stored:
1. The command file sopcopy.txt is stored on diskette (batch mode).
2. The command file sopcopy.txt is stored on the hard disk in the following directory:
<SOP installation directory>\CONF (dialog mode).
43
Copy files
44
Copy files
45
Export journal
Export journal
The "Export journal" function is used to export the journal files in which customer
transactions are logged to diskette. A separate journal file is created for each day. The
last ten journal files can be exported with this function.
A door has to be opened to insert the diskette in the drive.
Procedure:
Select the "Export journal" function.
The program displays a list of journal files
which can be exported. For each journal
file the respective date is displayed.
Select the journal file to be exported by
entering the number assigned to it.
46
Export journal
47
Procedure:
Select the "Export SOP journal" function.
Synchronize with the customer application
if necessary.
You can choose whether you want to
export the SOP journal to the hard disk or
to diskette.
48
49
Exporting to diskette
You start the process of exporting the SOP
journal to diskette by entering "2". A file
named sopjrnl.nnn is created (nnn=001
for the first diskette).
Synchronize with the customer application
if necessary.
A door has to be opened to access the
diskette drive.
You are prompted to insert a diskette in
drive A:.
The SOP journal file is exported when you
have inserted the diskette and pressed
"OK".
If more than one diskette is needed to
export the file, a message appears
prompting you to insert another diskette.
50
Start traces
Start traces
The "Start traces" function is used to start additional logs (traces) for various software
components of the self service device in order to analyse errors. This function should only
be performed when it is requested expressly. Before starting normal operation, all traces
have to be deactivated again by calling the "Stop traces" function.
Procedure:
Select the "Start traces" function.
The program displays a list of all traces
that can be activated. This list covers
several pages. You activate the trace by
entering the number assigned to it.
51
Stop traces
Stop traces
If traces have been activated, they can be deactivated again by means of the "Stop
traces" function. It is important to stop all traces before restarting normal operations.
Procedure:
Select the "Stop traces" function.
You are asked whether you really want to
carry out the function.
52
Export trace
Export traces
The "Export trace" function exports the trace file to the hard disk or to diskette. This
process deletes the contents of the trace file. The exported file can be evaluated outside
the self service device.
Procedure:
Select the "Export trace" function.
Synchronize with customer application if
necessary.
You can choose whether you want to copy
the trace file to hard disk or to diskette.
53
Export trace
54
Export trace
Exporting to diskette
You start the process of exporting the trace
file to diskette by entering "2". A file named
trace.nnn (nnn=001 for the first diskette) is
created on the diskette.
A door has to be opened to access the
diskette drive.
You are prompted to insert a diskette in
drive A:.
The trace file is exported when you have
inserted the diskette and pressed "OK".
55
Export diagnostics
Export diagnostics
The "Export diagnostics" function is used to export the diagnostic file to hard disk or to
diskette. The exported file can then be evaluated outside the self service device.
Procedure:
Select the "Export diagnostics" function.
Synchronize with customer application if
necessary.
You can choose whether you want to
export the file to hard disk or to diskette.
56
Export diagnostics
57
Export diagnostics
Exporting to diskette
You start the process of exporting the
diagnostic file to diskette by entering "2". A
file named error.nnn is created on the
diskette (nnn=001 for the first diskette).
A door has to be opened to access the
diskette drive.
You are prompted to insert a diskette in
drive A:.
The diagnostic file is exported when you
have inserted the diskette and pressed
"OK".
If more than one diskette is needed to
export the file a message appears telling
you to insert another diskette.
58
Adjust bell
Adjust bell
The "Adjust bell" function is used to adjust the loudness of the bell. A chassis door has to
be opened for this purpose.
Procedure:
Select "Adjust bell" function.
Synchronize with customer application if
necessary.
Open device door.
Adjust loudness of bell by turning the
volume regulator.
"OK" terminates the function and returns control to the previous menu.
59
IDKG-Status anzeigen
IDKG
Procedure:
Select the "Show IDCU status" function.
"OK" terminates the function and returns
control to the previous menu.
Alternative texts
Depending on the ID card unit status the following texts can be shown in various
combinations:
60
ID Card Unit
Procedure:
Select the "Remove retained ID cards"
function. The number of cards that has
been retained is displayed.
If no ID cards have been retained, the
program gives the message "No cards
retained".
61
ID Card Unit
Procedure:
Select the "Remove jammed ID cards"
function.
If there is no jammed card in the device,
you will get an appropriate message and
the function will be terminated.
Synchronize with customer application if
necessary.
If a card is jammed in the ID card unit, turn the adjustment wheel on the ID card unit to
move the jammed card out of the unit.
When you have confirmed the displayed message, the function is terminated and
control returns to the previous menu.
62
ID Card Unit
The keys have a hexadecimal format (digits 0 9, letters A F). Refer to chapter
"Fundamentals" for input of the letters A to F.
The key is concealed when it is entered. An asterisk is displayed for each digit or letter
that is typed.
Organizational procedures can be instated to ensure that this is done by a second user.
63
ID Card Unit
Procedure:
Select the "Load CIM86 key" function.
Synchronize with customer application if
necessary.
Enter the first half of the key.
64
ID Card Unit
65
Cash units
Cash Units
Show cash units status
The "Show cash units status" function displays information on the status of the
retract/reject cash unit and on the cash-out units.
This document describes two types of cash unit counters:
Physical cash unit balance
Logical cash unit balance (including reject bin)
Only the names logical cash unit balance and physical cash unit balance will be used in
the rest of this text.
The logical cash unit balance is displayed by default.
Procedure:
Select "Show cash unit status" function.
The cash unit status is displayed as
shown.
"OK" terminates the function and returns
control to the previous menu.
The following status information is displayed, depending on the cash unit type. The
information on currency and denomination will only be displayed for cassettes where the
assignment is obviously.
Column1: Cash unit type
Column 2: Currency
Column 3: Denomination
Column 4: Logical cash unit balance
Column 5: Status of cash unit
66
Cash units
def
New
The cash unit has just been inserted and has not been updated yet
RefW
lock
<min
The number of notes in the cash unit is less than or equal to the
minimum specified
Empty
#1 missing
REJ full
REJ high
67
Cash units
Procedure:
The cassette unit status is displayed as
shown.
The column arrangement for the cash-out
units will not be changed.
Column 4 shows the current contents of
the cash unit.
Column 4, refering to the reject bin (REJ), shows the number of notes retained due to
test dispensing, reference value determination or dispensing errors.
Number of retained notes for each cashout unit (Rej.: #O2 3)
Shows max. amount which can be paid out
determined from the current amount of the
cash-out unit.
When showing cash unit status information, the modified way of displaying cash unit
counters has effects on the following functions:
Complete exchange
Refill cash units
Setup reference value
Release cash units
Set cash unit counter
Sum up cash unit counters
Test dispensing
Check transport
68
After dispensing errors or a double dispense the physical cash unit balance
may not correspond to the cassette contents. Only the sum of physical cash
unit balance + number of notes retained corresponds to the logical cash unit
balance.
Cash units
Only CSCs featuring a cash-out unit with a shutter support the retract function.
69
Cash units
Cash which has been extracted from the cash-out units but not actually paid out (e.g.
cash that has been transported to the reject bin after dispensing errors) belongs to the
logical cash unit balance. The contents of a cash unit shown in the cash unit status
test is the total of the actual contents of the cash unit plus the number of notes that
have been transported to the reject bin of the retract/reject cash unit.
Retention of cash that has been made accessible to the customer (retract)
The number of retracts allowed can be defined:
No retracts (0)
No retracts are allowed.
Defined retracts (DEF)
Two types of retracts are allowed. The cash retained from the first transaction is
transported to the retract bin of the retract/reject cash unit. The cash that is retained
from the second retract remains in the stacker. Thus it is possible for each transaction
with retract to determine the amount of cash retained. The retract lock is set.
Maximum number of retracts (MAX)
Up to 99 retracts are allowed. The retained cash is transported to the retract bin of the
retract/reject cash unit. It is not possible to find out how much cash was retained in
which transaction.
Enter number
If this function key is selected, it is possible to enter the maximum number of retracts
possible (0-99). Contrary to "Defined retracts", the "2" entered here indicates that a
maximum of 2 retracts is transported to the retract bin of the retract/reject cash unit.
Retention of cash that has not been made accessible to the customer (reject)
Cash which has been extracted from the cash-out units but has not actually been paid out
as a result of
dispensing errors,
test dispensing,
reference value determination or
an aborted transaction before the dispensed cash was made accessible to the
customer
is placed in the reject bin of the retract/reject cash unit. This cash belongs to the
logical cash unit balance and must be included in calculations relating to this.
70
Cash units
The status of a reject cash unit will not be displayed on the operator panel if it
is "ok". So its possible to display information for 4 cash units on one screen.
Refer to chapt. "Show cash unit status" for the physical cash unit balance.
71
Cash units
72
Cash units
73
Cash units
74
Cash units
After a cash unit exchange the status of the reject cash unit is usually "ok and
will therefore not be displayed.
75
Default exchange
Cash units
Default exchange
All cash units can be exchanged with the "Default exchange function. The procedure is
described in the section entitled "Basic steps to exchange cash units. When all cash
units have been reinserted, the filling data is updated automatically from the default table.
How this table is created and modified is described in the "Update default table section.
The number of notes in the cash unit that has been inserted is determined by means of
the cash unit number and the associated entry in the default table. If a cash-out unit is
inserted for which no entry has been made, an appropriate error message will be
displayed and the cash unit will not be logged on.
Since all cash units including the retract/reject cash unit are exchanged, both the retract
and reject counters are set to zero when the cash unit data is updated. Any retract lock
which has been set is canceled.
Procedure:
Select function "Default exchange".
Synchronize with the customer application if necessary.
The current cash unit status is displayed.
Open safe door if necessary.
Remove all cash units and insert new ones (refilled). If less cash units are inserted
than the number of cash unit chutes, then the message "Only confirm for premature
end is displayed. The message has to be confirmed as well as the next questions
checking whether you really intend this.
76
Cash units
Default exchange
77
Complete exchange
Cash units
Complete exchange
All cash units can be exchanged with the "Complete exchange" function. The procedure
is described in the chapter "Basic steps to exchange cash units. When all cash units
have been reinserted you have to enter the filling data.
Since all cash units including the retract/reject cash unit can be exchanged, both the
retract and reject counter are set to zero when the cash unit data is updated. Any retract
lock is canceled.
Procedure:
Select the "Complete exchange function.
Synchronize with the customer application if necessary.
The current cash unit status is displayed.
Open safe door if necessary.
Remove all cash units and insert new ones (refilled). If less cash units are inserted
than the number of cash unit chutes, then the message "Only confirm for premature
end is displayed. This message has to be confirmed as well as the next question
checking whether you really intend this.
You update the filling data by entering the note count or the amount.
After the update the current cash unit data is displayed.
"OK terminates the functions and returns control to the previous menu.
78
Cash units
Procedure:
Select the "Refill cash units function.
Synchronize with the customer application
if necessary.
The physical cash unit balance1 of the
cash-out units is displayed.
Refer to chapt. "Show cash unit status" for physical cash unit balance.
79
Cash units
80
Cash units
Procedure:
Select the "Initialize cash units function.
The current cash unit data is displayed.
81
Cash units
If checking the cash unit numbers against the cash unit table has been disabled, any
cash unit number can be entered. If this check has been enabled, however, the cash unit
number must have been entered in the cash unit table.
If the cash unit number has already been assigned to another cash unit in the CSC, it is
rejected.
82
Cash units
After the initialization of cash units, a cash unit exchange has to be performed
to release the initialized (and thus "empty") cassettes!
83
Cash units
After installation
When new types of notes are used
When new types of currencies are used
When the controller has been replaced
If the "RefV" or "Reference value missing" cash unit status is displayed
If any cash is lying in the stacker as a result of a retract, then this function is terminated
for reasons of consistency and a message to this effect is output. In this case the function
"Remove customer money" has to be selected in order to remove the cash from the
stacker and from the retract bin of the retract/reject cash unit. Only then can the "Setup
reference value" function be selected again.
Refer to the operating instructions for the CSC to see how cash is removed from the
stacker of the cash dispenser module.
84
Cash units
Procedure:
Select the "Setup reference value"
function.
The contents of the cash unit is displayed.
If a cash unit is flagged with an asterisk,
this means that a reference value was
determined for this cash unit in a previous
run of this function.
You have to enter the number of the cash
unit for which you want to determine the
reference value of the note type.
Synchronize with the customer application
if necessary.
Open safe door if necessary.
The program starts to determine the
reference value.
85
Cash units
86
Cash units
Counter discrepancies!
Cash unit counters are assigned to the cash unit chutes. Currency,
denomination and note type, however, are assigned to the cash units.
Changing cash units results in counter discrepancies.
Since the user does not enter any counters, the counters of the retract/reject cash unit
will not be changed, too. If a retract lock has been activated, the function is not allowed to
be selected.
87
Cash units
Procedure:
Select the "Release cash unit" function.
The physical cash unit balance1 of the
cash-out units is displayed.
Synchronize with the customer application
is necessary.
The safe door will not be monitored in this
function.
You may select cash units with the status
"new". Only selected cash units are
released. Via parameter it is possible to
release all cash units with the status "new"
without any selection.
88
See chapt. "Show cash unit status" for displaying physical cash unit balance.
Cash units
This simplified function can also be used to check cash units, to exchange
defective cash units or to check the transport, since the cash unit counters will
not be modified.
89
Cash units
Procedure:
Select the "Set cash unit counters"
function.
The current contents1 of the cash-out units
is displayed.
Synchronize with the customer application
if necessary.
The safe door is not monitored in this
function.
Update the filling data by entering the
number of notes or the amount. It is only
allowed to enter filling data for cassettes
with the status "new, "min or "ok.
The following information is displayed:
Column 1: Currency
Column 2: Denomination
Column 3: Number of notes
90
Refer to chapt. "Show cash unit status" for physical cash unit balance.
Cash units
Counters are also set for cash units which have not been exchanged. Please
note that both cash unit counters ("current cash unit counter" and "current cash
unit counter + reject counter") are set.
91
Add counters
Cash units
Add counters
The counters of all newly inserted cash units are increased by the value you enter with
the "Add counters" function.
The cash units are not monitored, i.e. the number of notes by which the cash unit
counters are increased is entered directly after selection and synchronization of the
function.
Procedure:
Select "Add counters" function.
The current contents1 of the cash-out units
is displayed.
Synchronize with the customer application
if necessary.
The safe door is not monitored in this
function.
The filling data of all cash units which have
been newly inserted is allowed to be
entered.
You update the filling data by entering the
number of notes.
The following information is displayed:
Column 1: Currency
Column 2: Denomination
Column 3: Number of notes
92
See chapt. "Show cash unit status" for displaying the physical cash unit balance.
Cash units
Add counters
Cash units which have been removed and for which no counters have been
entered, are released again without updating their counters! (Current cash unit
counter and current cash unit counter + reject counter will not be changed).
93
Procedure:
Select the "Show cash dispenser status"
function.
"OK" terminates the function and returns
control to the previous menu.
94
Check transport
Check transport
Notes which are blocking the transport paths can be removed with the "Check transport"
function.
If a retract is the cause of the cash lying in the stacker, then this function is terminated for
reasons of consistency and a message to this effect is displayed. In this case, the
"Remove customer money" function has to be selected in order to remove the cash from
the stacker and from the retract bin of the retract/reject cash unit.
Refer to the operating instructions for the CSC to see how cash is removed from the
transport paths.
Procedure:
Select the "Check transport" function.
If no cash is on the transport paths, a
message is shown on the display.
"Cancel" terminates the function and
returns control to the previous menu.
"OK" starts the function.
Synchronize with the customer application
if necessary.
If cash that has been made accessible to
the customer is on the transport paths a
message is shown on the display.
"OK" terminates the function and returns
control to the previous menu.
Note: Cash that has been made
accessible to the customer and then
retracted can only be removed from the
transport paths by means of the
95
Check transport
96
Check transport
97
Check transport
98
Refer to the operating instructions for the CSC to see how cash is removed from the
transport paths.
Procedure:
Select the "Remove customer money"
function.
Synchronize with the customer application
if necessary.
If no money has been retracted, a
message is shown on the display.
"OK" terminates the function and returns
control to the previous menu.
Open safe door if necessary.
If no cash is on the stacker the following
message is displayed.
99
100
101
Move shutter
Move shutter
The "Move shutter" function is used to test whether the shutter is working properly. The
shutter can be opened or closed, or a self-test can be performed.
Procedure:
Select the "Move shutter" function.
Synchronize with the customer application
if necessary.
A menu is displayed.
102
Move shutter
103
The "Update cash unit table" function is used to enter cash unit numbers in the cash unit
table, delete them and enable or disable the cash unit number check option.
If the check option has been enabled, the program checks (in the functions Default
exchange", "Complete exchange" and "Initialize cash units") for each cash unit that is
inserted in the cash disenser module whether the cash unit number exists in the cash unit
table. The cash unit is only released for dispensing if the result of this check is positive.
The number of the retract/reject cash unit is not checked.
Any cash-out unit can be inserted if this check has been disabled.
Procedure:
Select the "Update cash unit table
function.
A menu is displayed.
"Cancel rejects the changes that have
been made.
"OK stores all changes and returns control
to the previous menu.
104
The scrolling keys (<< (F2) and >> (F3)) show the table page by page.
"Cancel ignores the delete marks* and returns to the Cash unit table menu.
"OK deletes the marked cash units in the displayed table.
105
Check on/off
The "Check on/off function enables/disables
the check of cash unit IDs.
The Check on/off dialog depends on the
actual state of the check.
If the check is enabled a message is
displayed.
"Cancel leaves the current state and returns to the Cash unit table menu.
"OK changes the state and returns to the Cash unit table.
106
The check cannot be enabled if there is a cash unit whose cash unit ID has not
been entered into the cash unit table.
The state of the check will only be changed when the OK button on the "Cash
unit table is pressed.
107
108
The cash unit numbers of the default table are automatically added to the cash
unit table!
"Cancel terminates the function, discards all changes and returns control to the
previous menu.
"OK saves all changes and returns to the cash unit selection menu.
109
"Cancel rejects all changes that have been made and returns to the cash unit
selection menu. The cash unit will not be marked here.
"OK saves all changes and returns to the cash unit selection menu. The cash unit will
be marked with an asterisk *.
110
Now you can select another cash unit and modify its data.
Delete cash unit
The Delete cash unit function supports the
deleting of existing table entries.
The current table entries can be selected
by entering the number assigned to it.
After selecting a number the cash unit will
be marked by a star * as to be deleted.
"Cancel ignores the delete marks * and returns to the previous menu.
"OK deletes the marked cash units and returns to the function selection.
111
Procedure:
Select the "Select denomination algorithm
function.
Synchronize with customer application if
necessary.
The algorithm that has been defined is
displayed.
"Cancel terminates the function. The
displayed denomination algorithm remains
in effect.
112
113
Procedure:
Select the "Max. no. of retracts function.
Synchronize with the customer application
if necessary.
The max. number of retracts allowed is
displayed.
Depending on the current setting '0', 'DEF',
'MAX' or the entered number is displayed.
"Cancel terminates the function. The max. number of retracts allowed remains in
effect.
After confirmation a list to define the max.
number of retracts is displayed.
You select the max. number of retracts by
entering the number assigned to it.
114
115
Test dispensing
Test dispensing
Notes are dispensed from each valid cash-out unit with the "Test dispensing" function and
then directly transported to the reject bin of the reject/retract cash unit.
Procedure:
Select "Test dispensing" function.
Synchronize with the customer application
if necessary.
Dispensed notes are directly transported to
the reject bin.
"OK" terminates the function and returns to
the previous menu.
116
HW device status
HW device status
The "HW device status" displays information on the hardware of the dispenser.
Procedure:
Select "HW device status" function.
Hardware information on the dispenser is
displayed.
"OK" terminates the function and returns
control to the previous menu.
The displayed information depends on the hardware equipment of the dispenser. Refer to
the CSC-W / CSC-O documentation for details on the individual status information.
The status can be displayed with a higher resolution, depending on the operator panel
installed.
117
Procedure:
Select "HW cash unit status" function.
Hardware information on cash units is
displayed.
"OK" terminates the function and returns
control to the previous menu.
The displayed information depends on the hardware equipment and the state of the cash
unit. Refer to the CSC-W / CSC-O documentation for details on the individual status
information.
The status can be displayed with a higher resolution, depending on the operator panel
installed.
118
Display Version
Display Version
The function "Display Version" displays versions of the following software components:
WOSA/XFS BSI Release of CDM
CSCW/O Release
CNG Firmware Release
CNG Boot Release
Procedure:
Select "Display Version" function.
Versions are displayed.
"OK" terminates the function and returns
control to the previous menu.
119
Coin-Out module
Coin-Out module
Show Coin-Out Status
The "Show Coin-Out Status" function is used to give information on the status of the
Coin-Out cylinders.
A Coin-Out module includes a maximum of 6 Coin-Out cylinders.
It is not possible to retract coins which have already been dispensed. For this reason the
Coin-Out module neither has a reject nor a retract cassette.
The chassis door and the output tray cannot be monitored.
Procedure:
Select "Show status of Coin-Out module"
function.
The status of the Coin-Out cylinders is
given as shown.
"OK" terminates the function and returns
control to the previous menu.
The letter "H" (hopper) describes the cassette type.The following status information is
given, depending on the cassette type.
1. Column: Cassette type
2. Column: Currency
3. Column: Denomination
4. Column: Logical cash unit balance of Coin-Out cylinders
5. Column: Status of Coin-Out cylinders
120
Coin-Out module
Def
Lock
<min
The number of coins in the Coin-Out cylinder is lower than or equals the
minimum number.
Empt
#1 miss
121
Refill Coin-Out
Coin-Out module
Refill Coin-Out
The "Refill Coin-Out" function is used to fill one or several coin cylinders with coins.
Procedure:
Select "Refill Coin-Out module" function.
Synchronize with customer application, if
necessary.
The current contents1 of the coin cylinders
are displayed.
122
See chapter "Show status of Coin-Out module" for current coin balance.
Coin-Out module
Refill Coin-Out
123
Empty Coin-Out
Coin-Out module
Empty Coin-Out
The "Empty Coin-Out" function is used to empty the coin cylinders one after the other.
Procedure:
Select "Empty Coin-Out module" function.
Synchronize with customer application, if
necessary.
The current contents1 of the coin cylinders
are displayed.
124
See chapter "Show status of Coin-Out module" for current coin balance.
Coin-Out module
Empty Coin-Out
125
Empty Coin-Out
Coin-Out module
126
Coin-Out module
Initialize Coin-Out
Initialize Coin-Out
The "Initialize Coin-Out" function is used to modify the following data in the non-volatile
storage of a coin cylinder :
Currency
Denomination
The coin cylinders which are to be initialized have to be entered into the Coin-Out
module.
Procedure:
Select "Initialize Coin-Out module"
function.
Synchronize with customer application, if
necessary.
The current contents1 of the coin cylinders
are displayed.
See chapt. "Show status of Coin-Out module" for current coin balance.
127
Initialize Coin-Out
Coin-Out module
128
Coin-Out module
Initialize Coin-Out
129
Probevereinzelung
Auszahleinheit
Test Dispense
The "Test Dispense" function is used to dispense one coin out of each coin cylinder and
to transport it to the output tray.
Procedure:
Select the "Test dispensing" function.
A message is displayed indicating that the
coins will be subtracted from the coin
balance when test dispensing is
performed.
"Cancel" terminates the function and
returns control to the previous menu.
"OK" starts the function.
Synchronize with customer application, if
necessary.
Dispensed coins are directly transported to
the output tray.
"Cancel" terminates the function and
returns control to the previous menu.
130
Coin-Out module
Display Version
Display Version
The function "Display Version" displays versions of the following software components:
WOSA/XFS BSI Release of Coin-Out
CSCW/O Release
CNG Firmware Release
CNG Boot Release
Procedure:
Select "Display Version" function.
Versions are displayed.
"OK" terminates the function and returns
control to the previous menu.
131
Display Version
132
Coin-In module
Coin-In module
Show Coin-In Status
The "Show Coin-In Status" function is used to give information on the status of the CoinIn module.
The Coin-In module consists of a filling tray, an output box, one Coin-In cassette and a
temporary coin storage. In the latter all coins which have been identified are stored until
they are transported to the Coin-In cassette.
The safe doors are not monitored.
The following information is given in the status overview:
Status of Coin-In module / ready, not ready
Status of temporary coin storage or stacker / empty, not empty
Status of Coin-In cassette / ok, empty, full, nearly full, locked, missing, defective
Overall number of coins paid into the Coin-In cassette.
All types of coins which can be paid in, as well as the number of paid-in coins for each
coin type.
Procedure:
Select "Show status of Coin-In module"
function.
The status of the Coin-In module is given
as shown.
"OK" terminates the function and returns
control to the previous menu.
133
Coin-In module
When using a graphic operator panel it is recommended that you use the 30 characters *
10 lines resolution.
134
Coin-In module
Empty Coin-In
Empty Coin-In
The "Empty Coin-In" function is used to empty the Coin-In cassette.
The Coin-In cassette is placed behind the rear safe door and can be pulled out by a
handle after the safe door has been opened.
Procedure:
Select "Empty Coin-In module" function.
Synchronize with customer application, if
required.
The current contents of the Coin-In
cassette are displayed.
Open rear safe door, pull out Coin-In
cassette and remove coins.
Press "OK" to contiue dialog.
"Cancel" terminates the function and returns to the previous menu.
135
Empty Coin-In
Coin-In module
136
Coin-In module
Procedure:
Select "Lock output box" function.
Synchronize with customer application, if necessary.
Put in output box, if necessary.
Output box is locked (illumination of output box is switched off).
Function is terminated.
137
Coin-In module
Procedure:
Select "Unlock output box" function.
Synchronize with customer application, if
required.
After the output box has been illuminated
you can remove it, empty it and put it in
again.
"OK" terminates the function and returns
control to the previous menu.
138
Coin-In module
Test Coin-In
Test Coin-In
The "Test Coin-In" function is used to check the transport paths, filling tray, output box,
coin identification module and the temporary coin storage.
Paid-in coins which have been identified by the coin identification module are transported
to the temporary coin storage. The counters are displayed and then the coins are
transported to the output box. The coins are not paid into the Coin-In cassette as this
would change the coin balance.
Coins which could not be identified are directly transported to the output box.
When the test Coin-In function is selected, the filling tray is illuminated. It has to be
opened manually, the coins have to be inserted and it has to be closed again manually.
Procedure:
Select "Test Coin-In" function.
Synchronize with customer application, if
required.
Open illuminated filling tray manually,
insert coins and close it again.
Continue dialog with "OK".
139
Test Coin-In
Coin-In module
140
Coin-In module
Display Version
Display Version
The function "Display Version" displays versions of the following software components:
WOSA/XFS BSI Release of Coin-In
CSCW/O Release
CNG Firmware Release
CNG Boot Release
Procedure:
Select "Display Version" function.
Versions are displayed.
"OK" terminates the function and returns
control to the previous menu.
141
Overview
142
Overview
143
EPP
Procedure:
Select the "Show EPP status" function.
The following information is displayed:
PIN pad status ("PIN pad ready / not
ready")
EPP status ("EPP ready / initialized / not
initialized")
List of all keys including
>key name<
>PIN< , if PIN key
key status ("loaded / not loaded)
"OK" terminates the function and returns control to the previous menu.
144
EPP
Configure EPP
Configure EPP
The "Configure EPP" function is used to define the keys which are loaded into the EPP.
Procedure:
Enter "0" to switch to the customer display for the rest of the dialog.
Synchronization with the customer application takes place.
Select the "Configure EPP" function.
145
Configure EPP
EPP
PIN key
Non-PIN key
Position:
1-32
35-128
The following functions can be selected via the function keys on the left:
New
Change type
Change position
Delete
New
A new key name can be defined with the "New" function. The key name has a length
of up to 12 characters, alphanumeric.
When you confirm the entry, the key is given the next free position for a non-PIN key
and is included in the key table shown on the screen. The program returns to the
function selection.
Change type
Use the scrolling keys to select a key. The "Change type" function is used to change
the key type in the table. The next free key position corresponding to the type of key is
automatically assigned.
Change position
Since keys are selected via their names, the position which has been given automatically
need not be changed. However, if key files created on an administration system have to
be loaded, the key positions have to be assigned explicitly to the key names, because the
administration only knows key positions.
146
EPP
Configure EPP
Use the scrolling keys to select the key whose position you want to change. Then
choose the "Change position" function and define a new key position. The key position
has to be entered as three digits. You can only define key positions which have been
assigned to the type of key in question.
"OK" stores the key position in the table that is shown on the screen.
"Cancel" terminates the function without updating the key position.
Delete
Use the scrolling keys to select the key to be deleted. Then choose the "Delete"
function and the key is removed from the key table that is shown on the screen.
Finally, "OK" stores the changes in the key table and returns control to the previous
menu.
"Cancel" terminates the function without updating the key table. The message
"Configuration not updated" is displayed and control returns to the previous menu.
147
Initialize EPP
EPP
Initialize EPP
The "Initialize EPP" function is used to initialize the EPP especially for manual input of
keys. The EPP ID and the transport key of the EPP are generated. All keys stored in the
EPP are deleted.
Procedure:
Select the "Initialize "EPP" function.
Synchronize with the customer application
if necessary.
The initialization process deletes all keys
that are stored except for the chip card
keys. To be on the safe side, the program
therefore asks you whether you really want
to initialize the EPP.
"Cancel" terminates the function.
"OK" initializes the EPP, generating the
EPP ID and the transport key in the
process.
148
EPP
Initialize EPP
149
EPP
Procedure:
Select the "Update key table" function.
A message is displayed with information on
the selection procedure.
150
EPP
For reasons of security the keys are entered in two halves which can be transported and
administered separately from each other.
Following is a description of how to set a plain text key and a transport-encrypted key.
Steps to enter a plain text key:
151
EPP
All keys have exactly 16 alphanumeric characters (digits 0-9 and letters A-F). The entry is
done hidden, i.e. each character is represented by an asterisk.
If the verifying input does not match the first input, an error message is displayed. This
message has to be confirmed and the verifying input has to be repeated. When the entry
has been terminated, the key is loaded into the EPP.
The current key entry can be terminated with "Cancel". The program returns control to the
previous menu.
Procedure:
Select the "Update EPP individually"
function.
Synchronize with the customer application
if necessary.
A message is given on how to select the
keys.
152
EPP
153
EPP
154
EPP
155
EPP
156
EPP
157
EPP
158
EPP
Procedure:
Select the "Update EPP sequentially" function.
Synchronize with the customer application if necessary.
The keys are processed as selected and configured in the key table. For the other
steps see the "Update EPP individually" function.
159
EPP
Procedure:
Select the "Enter initial master key"
function.
Synchronize with the customer application
if necessary.
Enter first half of the key (16 characters).
160
EPP
161
EPP
162
EPP
Procedure:
Select "Enter master key" function.
Synchronize with customer application if necessary.
For the other steps refer to the "Enter initial master key" function.
163
EPP
Procedure:
Select "Enter key exchange key" function.
Synchronize with the customer application if necessary.
For the other steps refer to the "Enter initial master key" function.
164
EPP
Procedure:
Enter "0" to switch to the customer display for the rest of the dialog.
Synchronize with the customer application if necessary.
Log in again at the customer display.
Select the "Initialize EPP via ID card" function.
You are prompted to insert the EPP ID card in the ID card unit. The card is drawn in,
read and ejected again.
The following conditions apply:
If either the ID card unit or the EPP is not ready, or if an ID card is jammed in the ID
card unit, then a message is displayed and the function is terminated when you
confirm it.
If an ID card is in the ID card unit but not jammed, then a message is displayed, the ID
card is output on the customer side and the function is continued with the card input
phase.
If an incorrect ID card is entered (no EPP ID and/or transport key), then a message is
displayed and the function is terminated when you confirm it.
The EPP is initialized when the EPP ID card has been output and removed. The EPP
ID and the transport key are stored in the EPP.
A message is displayed to show that initialization has been completed successfully.
"OK" terminates the function and returns control to the previous menu.
165
Load EPP
EPP
Load EPP
The "Load EPP" function reads all user keys from a key file (ADM*.TRD) and writes them
into the EPP. This file must have been created beforehand on an administration system
(ADMIN-KEY tool) and have been copied to a diskette or the root directory C:\ of the hard
disk. The EPP must have been initialized with the "Initialize EPP via ID card" function.
If the user key table is not available on the diskette or hard disk, or if it is empty or
inconsistent, a message is displayed and the function is terminated when you cnfirm it.
If the user key table contains a key that has not been configured (i.e. whose key position
has not been entered; see "Configure EPP" function, "Change key position"), a
corresponding message is displayed.
Procedure:
Select the "Load EPP" function.
Synchronize with the customer application
if necessary.
You can choose whether keys are to be
loaded from diskette or hard disk.
166
EPP
Load EPP
167
Load EPP
EPP
168
EPP
Load EPP
169
Deposit
Deposit
Show deposit status
The "Show deposit status" function gives information on the status of the device itself and
the corresponding components like container, envelope supply, dispenser, transport,
shutter and printer.
Procedure:
Select the "Show deposit status" function.
Deposit status information is displayed.
"OK" terminates the function and returns
control to the previous menu.
Alternative texts
Depending on the deposit module status the following status texts can be displayed in
various combinations.
170
Deposit
Empty deposit
Procedure:
Select "Empty deposit container function".
Synchronize with customer application if
necessary.
Open the safe door if necessary.
Afterwards the deposit container has to be
removed, all deposits must be taken, and
the container has to be reinserted again.
If no deposits are in the container, the
message "Container is empty" is displayed
and the function is terminated.
After the deposits have been taken it is
checked whether the deposit container has
been reinserted. If this is not the case, a
message is displayed.
171
Empty deposit
Deposit
172
Deposit
Procedure:
Select the "Clear deposit transport"
function.
Synchronize with the customer application
if necessary.
If the deposit container is missing or full,
you are prompted to insert the container or
to perform the function "Empty deposit".
173
Deposit
174
Scanner
Scanner
Show scanner status
The "Show scanner status" function gives information on the status of the scanner and
the associated retract bin.
Procedure:
Select "Show scanner status" function.
The status dialog is displayed as shown.
"OK" terminates the function and returns
control to the previous menu.
Alternative texts
Depending on the scanner state the following status texts can be displayed in various
combinations.
175
Scanner
Procedure:
Select the "Remove retracted documents"
function. The number of documents that
has been retracted is displayed.
If no documents have been retracted, the
program displays the message "No
retracted documents". "OK" terminates the
function and returns control to the previous
menu.
176
Printer
Printer
Show printer status
The "Show printer status" function gives information on the status of the printer and the
associated retract bin.
Procedure:
Select the "Show printer status" function.
The displayed status dialog is shown.
"OK" terminates the function and returns
control to the previous menu.
Alternative texts
Depending on the printer state the following status texts can be displayed in various
combinations.
177
Printer
Procedure:
Select the "Remove retracted documents"
function. The number of documents that
has been retracted is displayed.
If no documents have been retracted, the
program displays the message "No
retracted documents".
178
Procedure:
Select "Show PPD status" function.
The PPD status is displayed as shown. It
gives information on the operational status,
the current position and the position at
system start.
"OK" terminates the function and returns
control to the previous menu.
Alternative texts
Depending on the status of the Panel Protection Door (PPD) the following status texts
can be displayed in various combinations.
PPD "ready", "not ready", "moving", "defective"
PPD "open", "closed"
At system start PPD is "open", "closed", "unchanged"
179
Move PPD
Move PPD
The "Move PPD" function is used to test whether the Panel Protection Door is working
properly.
The following commands can be executed:
Open
Position 1 (service position)
Position 2 (customer position)
Close
Procedure:
Select the "Move PPD" function.
Synchronize with the customer application
if necessary.
You can start a function by entering the
number that is assigned to it.The door is
moved to the required position. If the door
is already in the selected position, it does
not move.
"Cancel" terminates the function and returns control to the previous menu.
180
Administration
Change password
Administration
Change password
The "Change password" function enables a user to modify his password.
Procedure:
Select the "Change password" function.
Enter your old password.
If "Password old" does not match the
active password, the message "Old
password not correct repeat entries" is
displayed.
Then you can enter a new password.
The new password must be confirmed by a second entry.
The function keys "F2" and "F3" can be used to navigate within the input fields.
Pressing "OK" on the last field releases the data. Pressing "OK" on the other two fields
brings the cursor to the next input field.
181
Change password
Administration
182
Administration
Administer profiles
Administer profiles
The function "Administer profiles" is used to create, change and delete the existing user
profiles. Since a user need not have or is not allowed to have access to all functions, the
profiles allow or lock functions.
A predefined superuser profile is shipped with the software. The superuser has the right
to access all functions in the component view.
Procedure:
Select the "Administer profile" function:
The existing user profiles are displayed. They are numbered when they are created.
You use this number to assign the profile to a user in the "Administer user" function.
183
Administer profiles
Administration
The following functions can be started via the function keys on the left:
Create profile
Change profile
Delete profile
Create profile
When you select the "Create profile" function you can define a new user profile name.
For this purpose an additional input field is displayed in the lower area of the dialog.
The user profile name has a maximum length of 20 alphanumeric characters.
"Correct" deletes the characters that have been entered and places the cursor at the
beginning of the field.
"OK" stores the new profile and returns control to the "Administer profiles" menu.
"Cancel" terminates the function without making any changes and returns control to
the "Administer profiles" menu.
Change profile
To change a profile use the scrolling keys to select the required profile. Then press the
"Change profile" function key to change the selected profile. The list of existing
functions can be displayed in the function view as well as in the component view.
These two views correspond to the views described in the "Structure of the SOP user
interface" chapter. However, the setting in the "Change profile" function does not define
the menu structure the user works with later on. The only thing that is defined here is the
structure in which the functions are arranged in the "Change profile" function.
The view that is in effect is indicated in the message box (e.g. "Function view is enabled.
Press "OK" for component view"). "OK" changes the view, "Cancel" retains the current
view. In both cases the menu of available functions is displayed.
To select the allowed SOP functions, the existing functions are displayed on the function
keys on the left in accordance with the view that has been set.
The following applies:
Green font:
Function allowed
Red font:
Function not allowed
Blue font
Menu item or function with subfunctions
184
Administration
Administer profiles
Pressing a function key allows or disallows access to the function (toggling between
green and red) or calls the next menu level.
You quit this function with "Cancel profile" or "Save profile" and the changes are
rejected or kept respectively. In both cases control returns to the "Administer profile"
menu.
Delete profile
To delete a profile, use the scrolling keys to select the required one. When you press
the "Delete profile" function key, the program deletes the profile in question without
asking whether you really want to do so. Control returns to the "Administer profiles"
menu.
185
Administer users
Administration
Administer users
The "Administer users" function is used to administer users who are allowed to handle
SOP. The administration includes creating, changing and deleting users. The view in
which the user is offered the menu can be defined as well.
A predefined user, the superuser, is shipped with the software.
Procedure:
Select the "Administer Users" function.
The program displays the users that have been defined and the view in which the
users can handle the SOP menu (refer to the "Structure of the SOP user interface"
chapter).
186
Administration
Administer users
Create user
Select the "Create user" function:
Name under which the user can be found in the user table (12
alphanumeric characters).
Identifier
to be entered for the identification process (8 digits).
Login
Must be defined if access control is enabled.
Password to be entered for the identification process (8
Password
digits). Need not be defined even if access control is enabled.
Assigned user profile number (2 digits).
Profile
Users language
Language
(3 letters), GER=German, ENG=English
Language selection Determines whether the language selection dialog is to be
presented to the user in the identification process (Y/N)
Name
187
Administer users
Rights
(Copy files)
Administration
The user ID and the login must be unique. The password is concealed when it is entered,
i.e. an asterisk is displayed whenever a character is typed.
Language and language selection are modified via the function keys on the left "Change
language" and "Change language selection" (toggle mode).
"Cancel" terminates the function without making any changes and returns control to
the "Administer users" menu.
"OK" stores the new user data and returns control to the "Administer users" menu.
Change view
To switch the user's view (function or component view) and thus change the structure of
his or her SOP menu, use the scrolling keys to select the required user. Then press the
"Change view" function key and change the view that is assigned to the user. In addition
to the standard views (function and component view) an individual menu can be
displayed, provided it has been configured.
Change user
To change the details of a user, use the scrolling keys to select the required user. Then
press the "Change user" function key and change the following data as applicable:
188
Password
Profile
Language
Language selection
Administration
Administer users
The current entries apart from the password are displayed. Use the scrolling keys to
move the cursor to the required input field. Then you can make the necessary changes.
The format of the inputs and any checks that need to be carried out are the same as
described in the "Create user" section.
"Cancel" terminates the function without making any changes and returns control to
the "Administer users" menu.
"OK" stores the new user data and returns control to the "Administer users" menu.
Delete user
To delete a user use the scrolling keys to select the required user. Then press the "Delete
user" function key. The program deletes the selected user without asking whether you
really want to do so.
The superuser cannot be deleted.
189
Administration
Procedure:
Select the "(En)Disable access control"
function.
This function indicates whether SOPs
access control option has been enabled or
disabled.
Here the access control option has been
disabled.
"OK" changes the current setting. "Cancel" terminates the function without changing
the current setting and returns control to the previous menu.
Press "OK" to change the current setting.
The new setting is displayed.
"OK" returns control to the previous menu.
190
Diagnostics
Show diagnostics
Diagnostics
Show diagnostics
All software modules which are used on the self service device write occurring errors into
the error log. The function "Show diagnostics" is used to show these errors on the
operator panel or on the customer screen. In most cases the entries are technicaloriented and serve the field engineers as a basis for problem analysis.
Procedure:
Select the "Show diagnostics" function.
You will get a list of errors written into the
error log.
If the operator panel has a resolution of 6 *
20, each entry has two lines containing
date, time, software component and error
class.
Usually the error log covers more than one page. You can navigate within the entry
using the "scrolling forward" and "scrolling backward" keys.
"OK" terminates the function and returns control to the previous menu.
As an alternative the graphic operator panel offers a resolution of 12 * 40. Filter settings
control the entries which are shown in the "Show diagnostics" function as well as the
sequence in which they are shown (see "Set filter" function).
By default the sequence in which the entries are shown depends on when they have
been entered, i.e. the entries which have been entered last are shown first.
191
Show diagnostics
Diagnostics
192
Diagnostics
Set filter
Set filter
The "Set filter" function is used to control the entry within the "Show diagnostics" function.
When SOP is started no filters are set by default and the latest error log entry is shown.
Procedure:
Select the "Set filter" function.
Within a dialog you can determine the
intervals for date and time. Modules can be
selected and the sequence of entries is
determined.
"OK" terminates the function and returns
control to the previous menu.
193
Set filter
Diagnostics
A link between start time and start date or end time and end date is not
possible, i.e. a link from 01.07.99 12:00 to 02.07.99 13:00 is not possible.
Entering this date and time offers you entries which have been placed on the
01.07.99 and on the 02.07.99 between 12:00 and 13:00 o'clock.
"OK" terminates the function and returns control to the "Set filter" function.
"Cancel" terminates the function without modifying the filter and returns control to the
"Set filter" function.
194
Diagnostics
Set filter
Enter modulId
Select the filter function "Enter modulId".
Enter modulld. The modullds are given in
the respective product descriptions.
"OK" terminates the function and returns
control to the "Set filter" function.
"Cancel" terminates the function without modifying the filter and returns control to the
"Set filter" function.
Determine start
Select the filter function "Determine start".
The current setting is shown.
"OK" switches the setting and returns to
the "Set filter" function.
Latest Oldest
Oldest Latest
"Cancel" terminates the function without
modifying the filter and returns control to
the "Set filter" function.
195
Abkrzungen
Abbreviations
196
CDM
CIM86
CSC
EDM
Encryption/Decryption Module
EPP
EPP-ID
IDCU
ID Card Unit
PIN
PPD
SOP
Glossary
Glossary
administration system
component
customer
customer application
customer display
default table
encryption/decryption module
key table
operator panel
reject
retract
shutter
197
Glossary
198
user
user card
user table
Appendix
Appendix
Structure of the sopcopy.txt command file
Command file on diskette
The command file sopcopy.txt must be stored in the root directory on the diskette. It is in
ASCII format, and each line constitutes a copy command. Apart from the copy function
program files can also be executed (e.g. post processing of copied files). If this is
requested, enter the "run" command instead of the destination drive/destination
directory.
A copy command has the following structure:
<FileName><Delimiter><SourceDrive><SourceDirectory><Delimiter><DestinationDrive>
<DestinationDirectory><CRLF>
The following applies:
Entry
Meaning
Range
FileName
Delimiter
Blank
SourceDrive
A: C: ...
SourceDirectory
199
Appendix
Delimiter
Blank
X'20'
DestinationDrive
A: C: ...
(run to start the source
program)
Acc. to operating system
X'0D0A'
200
Entry
Meaning
Range
MenuText
Delimiter
Blank
max. 17 characters
without blanks
X'20'
FileName
Delimiter
Blank
SourceDrive
A: C: ...
Appendix
SourceDirectory
Delimiter
DestinationDrive
X'20'
A: C: ...
(run to start the source
program)
Acc. to operating system
X'0D0A'
201
Appendix
Type
Admissible values
Default
[STARTUP]
MODE
C
MO, PM
MO
Mode in which SOP runs after the start:
MO SOP starts in monitoring mode (SOP taster, OPL keyboard, SYNC service, device
doors)
PM SOP is directly activated on front screen
LOGIN
C
Y, N
Y
Indicates whether a user has to log on to the system(Y) or not (N) after SOP has been activated
CUSTOMER_DISPLAY
C
OP, PM
PM
Indicates whether the customer screen is an operator panel or a VGA monitor:
OP Operator panel
PM front screen (presentation manager)
SYNCHRONISEIMMEDIATE
C
Y, N
N
SOP can be performed in parallel to the application, provided the transactions need no
synchronisation with the application. If parallel operation is rejected, the application can be
taken out of service directly after the login.
HAS_PM_WINDOWS_MONITOR
C
Y, N
Indicates whether the system has a VGA monitor.
ACCESS_VIA_DEVICEDOORS
C
Y, N
N
Indicates whether SOP has to be activated directly after a device door has been opened.
[STATUS_OVERVIEW]
DEVICE_SEQUENCE
[a-z]
DEVICES_TO_OMIT
C
[a-z]
Defines the components the status of which is not indicated in the status overview function.
202
Appendix
Parameter
[Range] Name
Type
Admissible values
Default
[TIMER]
INACTIVE_TIMEOUT
I
0, 60 bis 600
120
Number of seconds after the expiry of which (due to inactivity of user) SOP switches to the
monitoring mode. The timer is not valid within functions but only on menu level.
0 no time monitoring
LOGIN_TIMEOUT
I
0, 60 bis 600
120
Same meaning as INACTIVE_TIMEOUT. However, the timer is only in effect during the login.
0 no time monitoring
[DOORS]
MONITOR_ACTIVE
C
Y, N
Y
Indicates whether the device door (not the safe door) is monitored within functions or when
exiting SOP (Y) or not (N). The safe door is always monitored within functions and when a user
exits SOP!
MONITOR_ON_TIMEOUT
C
Y, N
Y
Indicates whether device door monitoring (except for safe door) is active when exiting SOP due
to user's inactivity (Y) or not (N).
IDCU
REAR_TOP
#NO
REAR_BOTTOM
FRONT_TOP
FRONT_BOTTOM
#NO
Indicates the door behind which the ID card unit is installed. The corresponding door is
monitored within functions which require access to the IDCU. (Only relevant if
MONITOR_ACTIVE=Y)
#NO no door monitoring
PC
C
see IDCU
Indicates the door behind which the PC is installed.
See IDCU
#NO
PTR
C
see IDCU
Indicates the door behind which the printer is installed.
See IDCU
#NO
SCN
C
See IDCU
Indicates the door behind which the scanner is installed.
See IDCU
#NO
203
Parameter
[Range] Name
Appendix
Type
Admissible values
Default
[LANGUAGE]
DEFAULT
[A-Z]
GER
currently: GER, ENG
Before a user logs on to the system, all SOP texts are displayed in the language set by default.
After a user's login, the texts are displayed in the language which has been set for this user. If
the user's login has not been activated, the superuser's language applies.
SELECTION
C
Y, N
N
Indicates if the user is offered a language selection dialog after SOP has been activated. The
further handling of SOP is then done in the language selected.The parameter will only be
evaluated, if SOP is running without login (LOGIN=N). If access control is activated, the
language selection dialog will only be offered if this has been configured for the user. (see SOP
administration)
AVAILABLE
T
[A-Z]
GER:ENG
This list contains the languages which are supported by SOP (currently:: GER German; ENG
English). The language abbreviations are separated by a colon. The language selection
dialog offers only those languages which have been defined in this parameter.
[LAYOUT]
DISPLAY_KEYB_FKT_KEYS
C
Y, N
N
SOP can be operated via a normal PC keyboard. For the front screen you can configure
whether the function key names on the buttons which are left and right of the softkeys are to be
displayed.
DIRECT_FUNCTION_ACCESS
C
Y, N
N
On the front screen the SOP functions are selected via softkeys, on the operator panel via the
menu items 1-4 or 1-8 (depending on the resolution of the screen). As an alternative each
function can be selected directly entering the function number.
SOFTKEYS
[A-Z]
SNI
NCR, SNI
On NCR compatible ATMs the softkeys are placed on a lower level. This parameter is used to
adapt the front screen layout to this modified softkey arrangement.
EPP_PAGE_UP
C
Y, N
Y
Indicates whether the correction key on the PIN pad means "scrolling backward" or correction.
204
Appendix
Parameter
[Range] Name
Type
Admissible values
Default
[OPP_INPUT]
PREEMPTIVE
C
Y, N
Y
The operator panel supports preentries, i.e. the entered characters are written into a buffer. You
can configure whether to use this feature in SOP.
[MESSAGE]
STOP_APPLICATION
C
Y, N
Y
Before SOP "stops" the application you are ask whether you really intend to stop it. This security
inquiry can be activated or deactivated.
[JOURNAL]
NO_OF_DAYS
I
1,31
7
SOP writes all activities into a journal file. This parameter specifies the number of days after the
expiry of which a backup is created from the current journal. After the backup has been made, a
new journal file is created.
[CDM_INFO]
COMPLETE_CASS_EX_CHANGE
C
Y, N
N
This parameter specifies whether the user has to exchange all cash units during a complete
exchange (by default not all cash units need to be exchanged).
RELEASE_ALL_CASS
C
Y, N
N
In the function "Release cash units" you can define whether all cash units are basically released
or whether you can chose from.
VIEW_CASS_STATUS_EX
C
Y, N
N
By default the logical cash unit balance (including the rejected notes) is displayed in all cash
unit functions. For more detailed information the parameter has to be set to "Y".
TEST_DISPENSE
C
Y, N
Y
When the cash unit functions have been terminated, you can specify whether to perform a test
dispensing to check if the cash units are ready to pay out.
EASY_CASS_EXCHANGE
C
Y, N
N
Two types of cash unit functions exist, normal and easy cash unit handling. The normal cash
unit handling is menu-driven and monitored. In the easy cash unit handling it is merely the
counters that are updated.
205
Parameter
[Range] Name
Appendix
Type
Admissible values
Default
WAITING_PERIOD
I
5,60
10
After the cash units have been inserted into the CSC a certain period of time may elapse until
the device recognizes that the cash unit is "available again". Here you can specify a certain
period of time which SOP waits before you can continue to make your entries.
DIALOG_DEFAULT_INPUT
C
C,A
C
The filling data are updated by entering the "note count" or the "amount".
DIALOG_TOGGLE_INPUT
C
Y, N
Y
In addition you can specify whether it is possible to switch from one input mode to the other
during the entry of the filling data.
PROCESS_UNCHANGED_CASSETTES
C
Y, N
N
This parameter is particularly used for the NDC/DDC emulation. Since the application releases
reentered cash units automatically with the old counters, a check upon a cash unit exchange is
not made.
OLD_COUNTERS_AS_DEFAULT_IN_ADD_CASH
C
Y, N
N
In the function "Refill cash units" you can specify whether the entered filling data are added to
the old ones.
[FORMDEFINITION_STATUS_FORM_EX]
T
20 @ 6; 30 @ 10
20 @ 6
PREFERRED_RESOLUTION
DEFAULT_RESOLUTION
The graphic operator panel allows a resolution which is higher than 20 @ 6 characters. The
DEFAULT_RESOLUTION refers to a special product (ProCash, ProPrint) and must not be
changed. The PREFERRED_RESOLUTION can be set to one of the values indicated.
Values refer to the extended status dialog.
[FORMDEFINITION_DIAG_ERROR_LIST]
T
PREFERRED_RESOLUTION
DEFAULT_RESOLUTION
Values refer to the diagnostic entries.
20 @ 6; 40 @ 12;
40 @ 6
20 @ 6
20 @ 6; 30 @ 10;
40 @ 6
20 @ 6
[FORMDEFINITION_SELECTION_MENU]
PREFERRED_RESOLUTION
T
DEFAULT_RESOLUTION
Values refer to the selection menu.
206
Appendix
Parameter
[Range] Name
Type
Admissible values
Default
[FIELDDEFINITION_COM_ENTER_ITEM_NO]
AUTO_END
T
YES,NO
NO
The item number selected need not be confirmed by default. If you request it, enter "YES".
[FONTS]
SOP_BUTTON
SOP_DLG_HEADER
SOP_DLG_TEXT
SOP_MSG_TEXT
SOP_REP_TEXT
SOP_STAT_DETAIL_LINE
SOP_STAT_HEADER
Helv,10,N
Helv Bold,12,N
Helv,10,N
Helv,10,N
Helv,12,N
Helv,10,N
Helv Bold,12,N
You can choose the font type for each text element of SOP.
Warning: If the font type you select is too big, the texts may overlap or are cut off.
[SERVICES_CUST]
ACTIVE
C
DLLS
C
Services according to customer requests
Y, N
A-Z a-z 0-9
Y, N
Y, N
Y, N
[SERVICES_USRX]
ACTIVE
User exit handling
[SERVICES_REP]
ACTIVE
Trouble shooting
[SERVICES_ADM]
ACTIVE
Administration
207
Parameter
[Range] Name
Appendix
Type
Admissible values
Default
Y, N
Y, N
Y, N
Y, N
Y, N
Y, N
Y, N
Y, N
[SERVICES_CDM]
ACTIVE
Cash dispenser module
[SERVICES_COUT]
ACTIVE
Coin out
[SERVICES_CIN]
ACTIVE
Coin in
[SERVICES_CSC]
ACTIVE
Self service device
[SERVICES_EPP]
ACTIVE
Encrypting PIN pad
[SERVICES_IDCU]
ACTIVE
ID card unit
[SERVICES_OPP]
ACTIVE
Operator panel
[SERVICES_DEP]
ACTIVE
Deposit
208
Appendix
Parameter
[Range] Name
Type
Admissible values
Default
Y, N
Y, N
Y, N
Y, N
Y, N
Y, N
Y, N
Y, N
[SERVICES_SCANNER]
ACTIVE
Scanner
[SERVICES_PTRJ]
ACTIVE
Journal printer
[SERVICES_PTRP]
ACTIVE
Passbook printer
[SERVICES_PTRD]
ACTIVE
Document/statement printer
[SERVICES_PTRR]
ACTIVE
Receipt printer
[SERVICES_TRACE]
ACTIVE
Trace (TLS2 / TLSW)
[SERVICES_SMI]
ACTIVE
System Management Information
[SERVICES_SYNC]
ACTIVE
Synchronisation
209
Parameter
[Range] Name
Appendix
Type
Admissible values
Default
Y, N
[SERVICES_DIAG]
ACTIVE
Diagnostics
[WOSA_PROFILES_ATM]
XFS_NAME
C
A-Z
Logical name of WOSA cash dispenser service
ATM
[WOSA_PROFILES_DEP]
XFS_NAME
C
Logical name of WOSA deposit service
A-Z
DEP
[WOSA_PROFILES_EPP]
XFS_NAME
C
A-Z
Logical name of WOSA encrypting PIN pad service
PIN
[WOSA_PROFILES_OPP]
XFS_NAME
C
A-Z
Logical name of WOSA operator panel service
TTU
[WOSA_PROFILES_PRD]
XFS_NAME
C
A-Z
Logical name of WOSA document printer service
PRD
[WOSA_PROFILES_PRJ]
XFS_NAME
C
A-Z
Logical name of WOSA journal printer service
PRJ
[WOSA_PROFILES_PRP]
XFS_NAME
C
A-Z
Logical name of WOSA passbook printer service
210
PRP
Appendix
Parameter
[Range] Name
Type
Admissible values
Default
[WOSA_PROFILES_PRR]
XFS_NAME
C
A-Z
Logical name of WOSA receipt printer service
PRR
[WOSA_PROFILES_SIU]
XFS_NAME
C
A-Z
Logical name of WOSA special electronics service
SIU
[WOSA_PROFILES_SSI]
XFS_NAME
C
Logical name of WOSA ID card service
A-Z
SSI
[WOSA_PROFILES_SMI]
XFS_NAME
C
A-Z
Logical name of WOSA system information service
SMI
[WOSA_PROFILES_SYN]
XFS_NAME
C
A-Z
Logical name of WOSA synchronisation service
SYN
[WOSA_PROFILES_SCN]
XFS_NAME
C
Logical name of WOSA scanner service
A-Z
SCN
A-Z
COUT
A-Z
CIN
[WOSA_PROFILES_COUT]
XFS_NAME
C
Logical name of WOSA coin out service
[WOSA_PROFILES_CIN]
XFS_NAME
C
Logical name of WOSA coin in service
211