Sunteți pe pagina 1din 76

(Integrated Management System (IMS) Certified Company)

Medium Voltage Electric Cable


3.3kv to 33kv

ou
y
ity
l
a
Qu

www.tirupatiplastomatics.com

Brand Name:

...
t
s
tru
n
ca

QUALITY
ASSURED
COMPANY

ENVIRONMENTAL
MANAGEMENT
SYSTEM

SAFETY
ASSURED
COMPANY

ISO 9001:2008

ISO 14001:2008

OHSAS 18001:2007

A VIEW OF STATE OF ART

PLANT AND OUR MANUFACTURING PROCESS & FACILITIES

Contents

Introduction ........................................................................................................................................................................1
Medium Voltage Cables Design and Construction to IEC 60502-2.................................................................................. 2-5
Electrical Parameters of the Cables to IEC 60502-2..............................................................................................
6-7
CURRENT RATINGS ......................................................................................................................................................... 8-13
Single Core Cable - CU/XLPE/PVC, 3.6/6KV to IEC 60502-2............................................................................................ 14
Three Core Cable - CU/XLPE/PVC, 3.6/6KV ..................................................................................................................... 15
Three Core Cable - CU/XLPE/STA/PVC, 3.6/6KV............................................................................................................... 16
Three Core Cable - CU/XLPE/SWA/PVC, 3.6/6KV ............................................................................................................ 17
Single Core Cable - CU/XLPE/PVC, 6/10KV .................................................................................................................... 18
Three Core Cable - CU/XLPE/PVC, 6/10KV ...................................................................................................................... 19
Three Core Cable - CU/XLPE/STA/PVC, 6/10KV ............................................................................................................. 20
Three Core Cable - CU/XLPE/SWA/PVC, 6/10KV ............................................................................................................. 21
Single Core Cable - CU/XLPE/PVC, 8.7/15KV ...................................................................................................................22
Three Core Cable - CU/XLPE/PVC, 8.7/15KV ................................................................................................................... 23
Three Core Cable - CU/XLPE/STA/PVC, 8.7/15KV ............................................................................................................ 24
Three Core Cable - CU/XLPE/SWA/PVC, 8.7/15KV .......................................................................................................... 25
Single Core Cable - CU/XLPE/PVC, 12/20KV ................................................................................................................... 26
Three Core Cable - CU/XLPE/PVC, 12/20KV ................................................................................................................... 27
Three Core Cable - CU/XLPE/STA/PVC, 12/20KV ........................................................................................................... 28
Three Core Cable - CU/XLPE/SWA/PVC, 12/20KV ........................................................................................................... 29
Single Core Cable - CU/XLPE/PVC, 18/30KV ................................................................................................................... 30
Three Core Cable - CU/XLPE/PVC, 18/30KV ................................................................................................................... 31
Three Core Cable - CU/XLPE/STA/PVC, 18/30KV ........................................................................................................... 32
Three Core Cable - CU/XLPE/SWA/PVC, 18/30KV ........................................................................................................... 33
General Characteristics of Cables to SANS1339............................................................................................................. 34
Manufacturing Range to SANS 1339 ............................................................................................................................... 35
Type of Cables to SANS 1339.......................................................................................................................................... 36
Construction of Cables to SANS 1339.............................................................................................................................. 37
Properties and applications .............................................................................................................................................. 38
Tirupati Type A - Three Core ............................................................................................................................................ 39-40
Tirupati Type A - Single Core........................................................................................................................................... 41-42
Tirupati Type B - Three Core ............................................................................................................................................ 43-44
Fault rating - kA for 1 sec (Copper) .................................................................................................................................. 45
Fault rating - kA for 1 sec (Aluminium) .............................................................................................................................. 46
Rating Factors ................................................................................................................................................................... 47-48
TABLE 1 3.8 / 6.6 KV HT XLPE SINGLE CORE ALUMINIUM CONDUCTOR CABLES to IS : 7098 (Part-2)...................... 49
TABLE 2 3.8 / 6.6 KV (E) HT XLPE SINGLE CORE COPPER CONDUCTOR CABLES...................................................... 49
TABLE 3 6.35 / 11 KV 6.6/11 KV (UE) HT XLPE SINGLE CORE ALUMINIUM CONDUCTOR CABLES........................... 50
TABLE 4 6.35 / 11 KV 6.6/6.6 KV (UE) HT XLPE SINGLE CORE COPPER CONDUCTOR CABLES................................. 50
TABLE 11-11 / 11 KV (UE) HT XLPE SINGLE CORE ALUMINIUM CONDUCTOR CABLES............................................. 51
TABLE 12 - 11 / 11 KV (UE) HT XLPE SINGLE CORE COPPER CONDUCTOR CABLES................................................. 51
TABLE 13 - 12.7 / 22 KV HT XLPE SINGLE CORE ALUMINIUM CONDUCTOR CABLES................................................. 52
TABLE 14 - 12.7 / 22 KV HT XLPE SINGLE CORE COPPER CONDUCTOR CABLES....................................................... 52
TABLE 15 - 19 / 33 KV HT XLPE SINGLE CORE ALUMINIUM CONDUCTOR CABLES................................................... 53
TABLE 16 - 19 / 33 KV HT XLPE SINGLE CORE COPPER CONDUCTOR CABLES......................................................... 53
TABLE 17 - 33 / 33 KV (UE) HT XLPE SINGLE CORE ALUMINIUM CONDUCTOR CABLES........................................... 54
TABLE 18 - 33 / 33 KV (UE) HT XLPE SINGLE CORE COPPER CONDUCTOR CABLES................................................. 54
TABLE 19 - 1.9 / 3.3 KV (E) & 3.3/3.3 KV (UE) HT XLPE THREE CORE ALUMINIUM CONDUCTOR CABLES ............... 55
TABLE 20 - 1.9 / 3.3 KV (E) & 3.3/3.3 KV (UE) HT XLPE THREE CORE COPPER CONDUCTOR CABLES...................... 55
TABLE 21 - 3.8 / 6.6 KV (E) HT XLPE THREE CORE ALUMINIUM CONDUCTOR CABLES ............................................ 56
TABLE 22 - 3.8 / 6.6 KV (E) HT XLPE THREE CORE COPPER CONDUCTOR CABLES................................................... 56
TABLE 23 - 6.35 / 11 KV (E) HT XLPE THREE CORE ALUMINIUM CONDUCTOR CABLES ........................................... 57
TABLE 24 - 6.35 / 11 KV (E) HT XLPE THREE CORE COPPER CONDUCTOR CABLES................................................. 57
TABLE 25 - 11 / 11 KV (UE) HT XLPE THREE CORE ALUMINIUM CONDUCTOR CABLES ........................................... 58
TABLE 26 - 11 / 11 KV (UE) HT XLPE THREE CORE COPPER CONDUCTOR CABLES.................................................. 58
TABLE 27 - 12.7 / 22 KV (E) HT XLPE THREE CORE ALUMINIUM CONDUCTOR CABLES ........................................... 59
TABLE 28 - 12.7 / 22 KV (E) HT XLPE THREE CORE COPPER CONDUCTOR CABLES................................................. 59
TABLE 29 - 19 / 33 KV (E) HT XLPE THREE CORE ALUMINIUM CONDUCTOR CABLES ........................................... 60
TABLE 30 - 19 / 33 KV (E) HT XLPE THREE CORE COPPER CONDUCTOR CABLES..................................................... 60
TABLE 31 - 33 / 33 KV (UE) HT XLPE THREE CORE ALUMINIUM CONDUCTOR CABLES ........................................... 61
TABLE 32 - 33 / 33 KV (UE) HT XLPE THREE CORE COPPER CONDUCTOR CABLES.................................................. 61
Handling Storage and Laying of HT Cables .....................................................................................................................62-64
Conversion Table .............................................................................................................................................................. 65

CERTIFICATES

Introduction
ABOUT
Tirupati Plastomatics Pvt. Ltd. A flagship company of Gemini Group of industries Jaipur India. The founder of the
company Mr. R.S. Gemini who is managing director & a well known industrialist & a renowned social worker.
Tirupati Plastomatics enjoys Status of an ISO-9001:2008, ISO 14001:2004, OHSAS-18001, BIS, SMEC Australia,
Scott Wilson-UK & SABS certified Company having a group turnover of Rs. 250.00 crores US$ 53.76 Million. The
company is one of the leading manufacturer of all kind of Manufacturing and Supply of PVC/XLPE LT & HT (up to
33kV) Fire Retardant/Polyethylene Insulated, Aluminium/Aluminium Alloy/Copper Conductor Cables,
Unsheathed/Sheathed, Armoured/Unarmoured, Screened/Unscreened Type Including Power, Control,
Submersible, Telecom, Coaxial, Radio Frequency, Computer, HF, VHF, UHF, Railway Signalling (Indoor/Outdoor)
Aerial Bunched LT & HT (Up to 33kV), PIJF Cables for Telecommunication Including (4/6 Quad) and Dry (4 Quad)
Cable, ACSR, AAC & AAAC Conductor (up to 400 kV) with own technical know-how for last ] 11 years being
widely used by Indian railways, utility service providers & private turnkey project executors in electricity
distribution, transmission & generation. Tirupati has a dedicated & well experienced team of techno commercial
experts.
In addition to serving Indian railways & electricity boards, Tirupati has also entered into overseas markets and
have executed orders of aerial bunched cables, LV underground cables & AAA conductors, ACSR conductors
as per IEC/VDE/DIN/SABS/ASTM/NF/BS specification to EDM, Mozambique, Mazare-E-Sharif power projects in
Afghanistan and to South African customers.

MISSION
Guided by the philosophy create the best to be followed by the rest, Tirupati Plastomatics aims at building a
zero-defect product, which will give value satistaction to its huge clientele. Tirupati Plastomatics strongly believes
that learning and improving is a continuous process for the total growth of the company.

VISION
Tirupati Plastomatics Pvt. Ltd., the name for dedication, devotion, discipline, discrimination and determination
has made a substantial growth plan with Rupees 1000 Crores turnover projection by 2015.

Awards & Recognition

Arch of Excellence Award 2002, All


India Organizational Confederation,
New Delhi.

Award from Business Initiative


Development Board 2004, New Delhi.

Indian Achiever Award of Industrial


Excellence for year 2008.

POLICY
Grow with customer by providing full customer satisfaction through quality product, support, timely deliveries &
new development, operate safe, healthy & clean environment. Comply with statutory requirements, all applicable
environment, health & safety legislation, prevention of ill health and injury, interests of all stakeholders, prevention
of pollution, and continual improvement in the effectiveness and performance of Integrated Management System
by improving process work practices and risk minimization through objective driven targets. Integrate quality
safety, health & environmental matters in all existing activities and future planning. Create & enhance awareness
among employees, society and other stakeholders about environment protection, minimization of waste, wise
use of energy, water & other natural resources, improve skill & competence of our employees and contractors so
as to enable them to demonstrate their involvement, for sound IMS performance.
Medium Voltage Cables

Medium Voltage Cables to IEC 60502-2 (Design and Construction )


Single-core or three core cables consist of the following components:

Conductor

Conductors are made of copper or aluminum. Conductor design is usually circular stranded, and compacted. Our
conductor design is in compliance with the requirements of IEC 60228 and BS 6360 Specification.

Insulation

Triple extrusion of inner semi-conductor (conductor screen), XLPE insulation, and outer semi-conductor (insulation
screen) is applied. XPLE insulation is Water cured. XLPE insulation material is as per the requirements of IEC 60502-2 or
as per customer's requirements.

Metallic screen

The metallic screen is usually made of copper wires or copper tape. Radial water sealing such as AL-Pe laminate and
longitudinal water sealing may be applied upon customer's request.

Assembly

All cable cores are laid-up together with usage of non-hygroscopic filler material. These fillers are temperature
compatible with all different cable layers such insulation, bedding and sheath.

Armouring

Armuor material can be either Aluminum for single core cables or Steel for multi-core cables. Armuor can be either wires
or tapes. Our cable armouring is in compliance with the requirements of IEC 60502-2 and BS 6622.

Outer sheath/ Jacket

Our cables sheaths are made of an extruded layer of PVC or PE material and are in compliance with the requirements of
IEC 60502-2 and BS 7655 Specification. We are also capable of providing cable sheaths with special requirements to be:
-

Termite retardant
Oil & Gasoline retardant
Ozone/ acid/ alkali retardent
Flame retardant and in compliance with requirements of IEC 60332-1 and IEC 61034-2
Low smoke Halogen Free and in compliance with requirements of BS 7211 and BS 6724

Testing of medium Voltage Power Cables

We Tirupati Plastomatics Cable Company, are capable of performing all standard routine tests and sample tests that are
normally carried out in accordance to IEC 6 0502-2 standards. We have all necessary equipment for such tests such as
high voltage labs and special ovens.
We are also capable of performing tests in accordance with international or national requirements as agree upon with
customers.

Routine Tests

- Measurements of the Electrical Resistance of Conductors


- Partial Discharge Test.
- High Voltage Test

Sample Tests

- Conductor Examination
- Check of Dimensions
- Hot Set Test for XLPE Insulations

Medium Voltage Cables

Medium Voltage Cables

Conductor

Conductor 1

Conductor Screen

Conductor Screen 2

Insulation

Insulation 3
Insulation Screen 4

Insulation Screen

Copper Tape Screen 5

Metallic Screen

Filler 6

Filler

Mylar Tape 7

PVC Bedding
Galvanized Steel wire Armour
(for Galvanized Steel Tape)
Other sheath

PVC Bedding 8
Steel Wire Armour 9
PVC Sheath 10

3 Cores XLPE Cable

Conductor

Conductor

Conductor Screen

Conductor Screen

Insulation

Insulation

Insulation Screen

Insulation Screen

Metallic Screen

Metallic Screen

Galvanized Steel Tape Armour

Other Sheath

Other Sheath

1 Core XLPE Cable

Medium Voltage Cables

General Information
Selecting A Power Cables
The following factor are important when selecting a suitable cable construction which required to transport electrical
energy from the power station to the consumer:
-

Maximum operating voltage


Insulation level
Frequency
Load to be carried
Magnitude and duration of
possible overload
Magnitude and duration of
short-circuit current

Voltage drop
Length of line
Mode for installation underground
(direct or in ducts) in air
Chemical and physical properties of soil
Max. and min. ambient air temperature and soil temperatures
Specification and requirement to be met

Voltage
The standard rated voltage of a cable is denoted by Uo/ U(Um),
where
Uo : is the rated power-frequency voltage between conductor and earth or metallic screen.
U : is the rated power-frequency voltage between conductors.
Um : is the maximum continuously permissible operating voltage of a cable at any time or in any part of the network.
Uo
/U

KV

3.6/6

6/10

8.7/15

12/20

18/30

Um

KV

7.2

12

17.5

24

36

Note :
Cable design for 6/10 and 18/30 kV is applicable for 6.35/11 and 19/33 kV respectively.

Standards
The cable described in this catalogue are all standard types, and their performance has been proved in operation,
Construction and test are in accordance with the recommendation of IEC publications where applicable.
Power cables in accordance to other standards (e.g. BS, VDE, NEMA) can be manufactured upon customer's
request.

Variation in Production and Delivery option


The provide data is approximate and subject to manufacturing tolerance Delivery length
tolerance is 5%

Jacket Marking
Standards embossed outer jacket marking consisting of :
1 - Name of manufacturer
2 - Type designation, size of conductor, rated voltage and standard.
3 - Continuous length marking every meter.
4 - Year of manufacture.

Medium Voltage Cables

Laying Information
Minimum Bending Radius During Installation
During laying, the bending radius should not be smaller than values given below.
The radius depends on the outer diameter (Do) of the cable.

XLPE insulated cables for 6.0 up to 30 kV


Minimum Radius

Types of Cable

Adjacent to joints or
terminations

During Laying

Single-core
- Unarmored
- Amoured

20 Do
20 Do

15 Do
12 Do

Three-core
- Unarmored
- Amoured

15 Do
12 Do

12 Do
10 Do

Maximum Tensile Forces During Laying


Means of pulling

Types of cable

Formula

With the pulling


head attached to
the conductors

All types of cable

P=s
.A

Factor
s
= 50N/mm2
(Copper conductor)
s
= 30N/mm2
(Alum. conductor)
2

With the pulling


stocking

Un-armoured
cables
Armoured cables

P=s
.A

= 50N/mm
s
(Copper conductor)
= 30Nmm2
s
(Alum. conductor)
K= 9/mm2

P=k.d2

P = Pull in N
A = Total cross section area in mm2 of all conductors (but not sceen or concentric conductor)
d = Outside diameter of the cable in mm

s = Permissible tensile stress of conductor in N/mm2

k = Empirically derived factor on N/mm2

Medium Voltage Cables

Electrical Parameters of the Cables

DC Resistance of Conductor

The Maximum DC resistance values of conductors at 20o C are as per "IEC 60228" standard.
DC resistance per unit length of the conductor at other conductor temperature are given by:
o
R=Ro [1+
20 C (t-20 C)]
o

where :
R

= DC resistance at temperature t C (
/ km)

Ro = DC resistance at temperature 20oC (


/ km) (given in the relative tables for each type of cable)
= Conductor temperature oC

o
o

20 C = Temperature coefficient at 20 C (1/ C)


o

For copper conductor


20 C = 0.00393
o

For aluminum conductor


20 C = 0.00403
o

A.C. Resistance of Conductor

The AC Resistance per unit length of the conductor (effective resistance) at its maximum operating temperature is made
up to the DC resistance at this temperature and the extra resistance which takes into account additional losses caused
by the current displacement in the conductor (Skin effect and Proximity effect). The AC resistance is given in the given in
the relative tables for each type of cable.

Inductance

The values of the inductance for both multicores and three single core cables have been calculated based on the
following presumption equation.
L = K+0.2 in (2S/d) (mH/km)
where:

K = a constant relating to the conductor formation (mH/km)


D = the conductor diameter (mm)
S = axial spacing between conductors for cables in trefoil formation (mm)
= 1.26 x axial spacing between conductors for cables in flat formation (mm)
The values for inductance of single core cables have been calculated based on one cable diameter between cables in
flat formation

Operation Capacitance

The Values of operating capacitance for cables have been calculated based on the following presumption :
C=

18 In (D)
d

m
f/ km

where :

= Relative permativity of insulation


r
D
d

= External diameter of insulation (mm)


= Conductor diameter (mm)

Operating temperature for XLPE insulated cables:


90oC for continuous normal operation

105oC for emergency overload conditions


250oC for short circuit conditions
6

Medium Voltage Cables

Charging Current

The charging current is the capacitive current which flows when AC voltage is applied to the cable as a result of the
capacitance between the conductors and metallic screen. The value can be derived from the equation.
where:

Ic = Uo
C 10-6
Uo = Voltage between phase and earth (V)

w =2
f (rad/s)

f = Frequency (Hz)
C = Capacitance to neutral (
F/ Km)

Dielectric Losses

The dielectric losses of an AC cable are proportional to the capacitance, the frequency, the phase voltage and dielectric
power factor. They are given by:
D= (2
f C Uo2 tan
) 10 -6 (watt/m/phase)
where:
f = Frequency Hz
C = Capacitance to neutral (
F/ Km)
Uo= Voltage between phase and earth (V)
tan
= Dielectric power factor

Voltage Drop

when current flows in a cable conductor, there is a voltage drop between the ends of the conductor which is the product of
the impedance. The following equations should be used to calculated the voltage drop:
1-

Single phase system


Vd = 2 (R cos
+Xsin
) (Volt/ amp/ meter)
2- Three phase system
Vd =
3 (Rcos
+Xsin
) (Volt/ amp/ meter)
where:
Vd = Voltage drop (V/am/m)
R = AC resistance of conductor at a maximum conductor temperature (
/km)
X = Inductive reactance of cable (
/km)
Cos
= power factor of load

Cable Short Circuit Current Capacity

The permissible short-circuit as presented in tables 11to13 are calculated in accordance with IEC 724, 1982. Which are
based on the following conditions:
1- Short circuit starts from the maximum operating temperature.
2- Maximum temperature during short circuit
XLPE = 250oC
PVC = 160oC
3- Maximum short circuit current duration is 5 seconds The short circuit current (I) shall be calculated from the formula.
I2= (K2 S2/T) In

q
1+b
(A)
q
2+b

where:
I
= Short circuit current (A.)
T
= Duration of short circuit (second)
K
= Constant for the material of the conductor
S
= Area of conductor (mm2)

= Final temperature (oC)


1

= Initial temperature (oC)


2

= Reciprocal of the temperature


coefficient of resistance (
) of the conductor
Medium Voltage Cables

CURRENT RATINGS
1- RECOMMENDATIONS FOR CURRENT RATINGS
The current rating of power cables is defined by the maximum intensity of current (in amperes), which can flow
continuously through the cable, under permanent loading conditions, without any risk of damaging the insulation or
deterioration of its electrical properties.
- Current carrying capacities have been calculated in accordance with IEC 60287 (calculation of the continuous current
rating of cables).
- The values given in the tables are valid for one circuit in three phase system under conditions specified. For grouping
cables rating factors must be used.
- It is to be observed that the current carrying capacities presented in TPPL technical data sheets are intended as a guide
to assist operating engineers in selecting cables for safety and reliability.
- Basic assumptions and conditions of installation:
* Ambient ground temperature :

20oC

* Ambient air temperature


* Depth of cable burial

:
:

30oC
1.0 m

* Thermal resistivity of soil

120oC.Cm/W

- Cables in air are assumed to be protected from direct solar radiation.


- Single core cables are installed as indicated in the technical information tables. Spacing between cables in flat formation
is assumed to be one cable diameter.
- For three and four-core cables, it is usual to assume the same current carrying capacity for four cores cables as for threecore cables. Our calculated values are based actually on three core cables. These values are suitable with enough
accuracy also for four cores cables in most cases. Only for large four cores cables in air the values may be found to be too
conservative, due to the large cable surface and consequent high heat dissipation factor.
- The inner diameter of ducts has been assumed to be least 1.5 times the diameter of the cables.
- To obtain the maximum current carrying capacity of a cable operating at different conditions from the standards, you
have to multiply the values of the current given in the technical information for the corresponding cable by the rating factors
mentioned in the tables from 1 to 10, as follow:
la = Kt ls in amperes
where:
la : Current rating at actual operating conditions (amperes)
is : Current rating at standard operating conditions (amperes)
Kt : Rating factor given the in the tables 1 to 10.
It has to be noted that Kt is the total rating factor : Kt =K1....K2.... Kn
You may have a multiplication of so many partial rating factors, as many as the difference of laying and operating
conditions from standard conditions.

Medium Voltage Cables

Table 1

RATING FACTORS K FOR VARIATION IN GROUND TEMPERATURE


o

GROUND TEMPERATURE C

20

25

30

35

40

45

50

55

PVC cables rated

70oC

1.00

0.95

0.90

0.84

0.78

0.71

0.63

0.54

PVC cables rated

85oC

1.00

0.96

0.92

0.87

0.83

0.78

0.73

0.67

XLPE cables rated 90oC

1.00

0.96

0.92

0.88

0.84

0.79

0.75

0.70

Table 2

RATING FACTORS K FOR VARIATION IN AIR TEMPERATURE


AIR TEMPERATURE oC

25

30

35

40

45

50

55

PVC cables rated

70oC

1.07

1.00

0.93

0.87

0.79

0.70

0.61

PVC cables rated

85oC

1.04

1.00

0.95

0.90

0.85

0.80

0.74

XLPE cables rated

90oC

1.04

1.00

0.96

0.91

0.87

0.82

0.76

Table 3

RATING FACTORS K FOR VARIATION IN GROUND DEPTH


DEPTH OF LAYING (m)
k

0.6

0.7

0.8

0.9

1.0

1.1

1.2

1.05

1.03

1.02

1.01

1.00

0.99

0.98

Table 4

RATING FACTORS K FOR VARIATION IN SOIL RESISTIVITY


SOIL RESISTIVITY (oC.cm/W)
k

80

90

100

110

120

150

200

250

1.17

1.12

1.07

1.00

0.91

0.91

0.80

0.73

Medium Voltage Cables

Table 5

TREFOIL OR FLAT FORMATION DERATING FACTORS FOR THREE


SINGLE CORE CABLES LAID DIRECT IN GROUND

NUMBER
OF
CIRCUIT

SPACING SPACING

SPACING SPACING

TREFOIL FORMATION

FLAT FORMATION

TOUCHING

SPACING = 0.15 M

SPACING = 0.30 M

NR

TREFOIL

FLAT

TREFOIL

FLAT

TREFOIL

FLAT

0.77

0.80

0.82

0.85

0.88

0.91

0.66

0.69

0.73

0.76

0.80

0.83

0.60

0.63

0.68

0.71

0.74

0.77

0.56

0.59

0.64

0.67

0.72

0.75

0.53

0.57

0.61

0.64

0.70

0.73

Table 6

TREFOIL OR FLAT FORMATION DERATING FACTORS FOR MULTI-CORE CABLES


LAID DIRECT IN GROUND
L

NUMBER
OF
CABLES

L
L

TREFOIL FORMATION
TOUCHING

10

FLAT FORMATION

SPACING = 0.15 M

SPACING = 0.30 M

NR

TREFOIL

FLAT

TREFOIL

FLAT

TREFOIL

FLAT

0.81

0.81

0.87

0.87

0.91

0.91

0.69

0.70

0.76

0.78

0.82

0.84

0.62

0.63

0.72

0.74

0.77

0.81

0.58

0.60

0.66

0.70

0.73

0.78

0.54

0.56

0.63

0.67

0.70

0.76

Medium Voltage Cables

Table 7

FLAT FORMATION DERATING FACTORS FOR THREE SINGLE CORE CABLES


LAID IN FREE AIR
Clearance = Cable diameter (d)
Clearance = from the wall 2 Cm

Number of circuit
1

2 cm

0.89

0.88

0.92

0.89

0.88

troughs

0.87

0.84

0.83

(circulation of air is

0.84

0.82

0.81

restricted)

0.82

0.80

0.79

Laid
on cable racks

Number of racks
1
2
3
6

2 cm

30 cm

Laid of cables

Number of troughs
1

0.92

d
d

2 cm

1.00
0.97
0.96
0.94

0.97
0.94
0.93
0.91

0.96
0.93
0.92
0.90

30 cm

Laid on the Floor

d
d

2 cm

Arranged near the wall

0.94

0.91

0.89

Arranged on the wall

0.89

0.86

0.84

Table 8

TREFOIL TOUCHING FORMATION DERATING FACTORS FOR THREE SINGLE


CORE CABLES LAID IN FREE AIR

Number of troughs
1

0.95

0.90

0.88

0.95

0.90

0.88

troughs

0.90

0.85

0.83

(circulation of air is

0.88

0.83

0.81

restricted)

0.86

0.81

0.79

1.00
1.00
1.00
1.00

0.98
0.95
0.94
0.93

0.96
0.93
0.92
0.90

Laid
on cable racks

Arrangements for
which reduction
of the current is not
necessary

Number of racks
1
2
3
6

2d
2d

2 cm

2d

2d

30 cm

Laid of cables

4d

2d

30 cm

Laid on the Floor

2 cm

30 cm

Number of circuit

Clearance = 2 (d)
Clearance from the wall 2 cm

Medium Voltage Cables

11

Table 9

HORIZONTAL OR VERTICAL FORMATION DERATING FACTORS FOR


MULTI-CORE CABLES LAID IN FREE AIR

Laid of cables

Number of troughs
1

0.95

0.90

0.88

0.85

0.84

0.95

0.90

0.88

0.85

0.84

troughs

0.90

0.85

0.83

0.81

0.80

(circulation of air is

0.88

0.83

0.81

0.79

0.78

restricted)

0.86

0.81

0.79

0.77

0.76

1.00

1.00

0.98
0.95
0.94
0.93

0.96
0.93
0.92
0.90

0.93
0.90
0.89
0.87

0.92
0.89
0.88
0.86

1.00

0.93

0.90

0.87

0.86

Laid
on cable racks

Number of racks
1
2
3
6

Arranged near the wall


Arrangements
for which reduction
of the current
is not necessary

1.00
1.00

Clearance
from the
wall

Clearance
between
cables

2cm

2d

2 cm

30 cm

Laid on the Floor

Number of Cables

30 cm

Clearance = Cable diameter (d)


Clearance from the wall 2 cm

2 cm

d
d

2 cm

2d
d

2 cm

2 cm

2d

Table 10

DERATING FACTORS FOR MULTI-CORE CABLES TOUCHING AND


IN CONTACT WITH THE WALL IN FREE AIR
Number of Cables

Laid on the Floor


Laid of cables

Number of troughs
1

0.90

0.84

0.80

0.75

0.73

0.95

0.84

0.80

0.75

0.73

troughs

0.95

0.80

0.76

0.71

0.69

(circulation of air is

0.95

0.78

0.74

0.70

0.68

restricted)

0.95

0.76

0.72

0.68

0.66

0.95
0.95
0.95
0.95

0.84
0.80
0.78
0.76

0.80
0.76
0.74
0.72

0.75
0.71
0.70
0.68

0.73
0.69
0.68
0.66

0.95

0.78

0.73

0.68

0.66

Laid
on cable racks

Number of racks
1
2
3
6

Arranged on the wall

12

Medium Voltage Cables

30 cm

30 cm

Clearance touching troughs


and contact with wall

Table 11 (90/250 oC)


SHORT CIRCUIT CURRENT FOR COPPER CONDUCTORS - XLPE INSULATED (KA)
Area
(mm2)

TIME (S)
0.1

0.2

0.3

0.4

0.5

16

7.24

5.12

4.18

3.62

3.24

2.29

1.62

1.32

1.14

1.02

25

11.31

8.00

6.53

5.66

5.06

3.58

2.53

2.07

1.79

1.60

35

15.84

11.20

9.14

7.92

7.08

5.01

3.54

2.89

2.50

2.24

50

22.62

16.00

13.06

11.31

10.11

7.15

5.06

4.13

3.58

3.20

70

31.67

22.40

18.29

15.84

14.16

10.02

7.08

5.78

5.01

4.48

95

42.98

30.39

24.82

21.49

19.22

13.59

9.61

7.85

6.80

6.08

120

54.30

38.39

31.34

27.15

24.28

17.17

12.14

9.91

8.59

7.68

150

67.87

47.99

39.19

33.94

30.35

21.46

15.18

12.39

10.73

9.60

185

83.71

59.19

48.33

41.85

37.43

26.47

18.72

15.28

13.24

11.94

240

108.59

76.79

62.70

54.30

48.56

34.34

24.28

19.83

17.17

15.36

300

135.74

95.98

78.37

67.87

60.71

42.93

30.35

24.78

21.46

19.20

Table 12 (90/250 oC)


SHORT CIRCUIT CURRENT FOR ALUMINUM CONDUCTORS - XLPE INSULATED (KA)
Area
(mm2)

TIME (S)
0.1

0.2

0.3

0.4

0.5

16

4.78

3.38

2.76

2.39

2.14

1.51

1.07

0.87

0.76

0.68

25

7.47

5.28

4.31

3.73

3.34

2.36

1.67

1.36

1.18

1.06

35

10.46

7.40

6.04

5.23

4.68

3.31

2.34

1.91

1.65

1.48

50

14.94

10.56

8.63

7.47

6.68

4.72

3.34

2.73

2.36

2.11

70

20.91

14.79

12.08

10.46

9.35

6.61

4.68

3.82

3.31

2.96

95

28.38

20.07

16.39

14.19

12.69

8.98

6.35

5.18

4.49

4.01

120

35.85

25.35

20.70

17.93

16.03

11.34

8.02

6.55

5.67

5.07

150

44.82

31.69

25.88

22.41

20.04

14.17

10.02

8.18

7.09

6.34

185

55.28

39.09

31.91

27.64

24.72

17.48

12.36

10.09

8.74

7.82

240

71.71

50.71

41.40

35.85

32.07

22.68

16.03

13.09

11.34

10.14

300

89.64

63.38

51.75

44.82

40.09

28.35

20.04

16.37

14.17

12.68

Table 13 (90/250 oC)


SHORT CIRCUIT CURRENT FOR COPPER SCREEN (KA)
Area
(mm2)

TIME (S)
0.1

0.2

0.3

0.4

0.5

16

7.24

5.12

4.18

3.62

3.24

2.29

1.62

1.32

1.14

1.02

25

11.31

8.00

6.53

5.66

5.06

3.58

2.53

2.07

1.79

1.60

35

15.84

11.20

9.14

7.92

7.08

5.01

3.54

2.89

2.50

2.24

Medium Voltage Cables

13

Single Core Cable


For installations outdoor in ground, in ducts and indoor on trays.
Type
Standard
Conductor
Conductor Screen
Insulation
Insulation Screen
Metallic Screen
Jacketing

:
:
:
:
:
:
:
:

CU/XLPE/PVC, 3.6/6 KV
IEC 60502-2
Circular stranded Compacted copper (or Aluminum)
Bonded semiconducting material
XLPE material
Strippable semiconducting material (or Bonded)
Annealed copper wires or (copper tape)
PVC compound (or LSHF or PE)

TECHNICAL INFORMATION
1. Weight and Dimension Data
Nominal
Cross
Section

Nominal
Insulation
Thickness

Nominal
Sheath
Thickness

Approx.
Overall
Diameter

Approx.
Cable
Weight

n x mm2

mm

mm

mm

kg/km

1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
1x400
1x500
1x630

2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.6
2.8
3.0
3.2
3.2

1.5
1.6
1.6
1.6
1.7
1.8
1.8
1.9
1.9
2.0
2.2
2.3
2.4

20.3
21.6
22.3
24.5
25.4
28.0
29.6
31.8
34.4
36.6
40.5
44.5
47.9

640
764
897
1126
1403
1657
2033
2387
2978
3610
4499
5497
7108

2. Electrical Data
Cross section Area
Screen Area

mm2

25

35

50

70

95

120

150

185

240

300

400

500

630

16

16

16

16

16

16

25

25

25

25

35

35

35

mm

DC Resist at 20oC

W
/ km 0.727

0.524

0.387

0.268

0.193

1.53

0.124 0.0991 0.0754 0.0601 0.0470 0.366

Ac Resist at 90oC

W
/ km 0.927

0.668

0.494

0.342

0.247

0.196

0.160 0.1290

0.099 0.0812 0.0657 0.0538 0.045

Inductance
Flat Formation
Trefoil Formation

mh/ km 0.495
mh/ km 0.449

0.467
0.421

0.440
0.394

0.417
0.371

0.400
0.353

0.384
0.338

0.380
0.331

0.368
0.322

0.355
0.420

0.349
0.303

0.345
0.299

0.338
0.292

0.328
0.283

Capacitance

m
F/ km 0.269

0.306

0.337

0.385

0.430

0.472

0.514

0.558

0.606

0.617

0.646

0.672

0.751

0.415

0.457

0.522

0.583

0.640

0.697

0.758

0.823

0.838

0.876

0.912

1.019

0.028

Charging current

A/ km

0.365

Dielectic losses

W/m

0.011

0.012

0.013

0.015

0.017

0.018

0.020

0.022

0.024

0.024

0.025

0.026

0.029

Cable in ground

170

195

235

265

305

345

395

455

500

560

635

710

790

Cable in free air

180

210

245

285

355

410

470

540

630

720

840

960

1100

Conductor S.C (1 Sec)

KA

5.01

5.0

7.15

10.0

13.5

17.1

21.4

26.4

34.4

42.9

57.2

71.5

90.0

Screen S.C (1 Sec)

KA

2.29

2.29

2.29

2.29

2.29

2.29

3.58

3.58

3.58

3.58

5.07

5.07

5.07

Current Ampacity

Short circuit current

14

Medium Voltage Cables

Three Core Cable

For installations outdoor in ground, in ducts and indoor on trays.


Type
Standard
Conductor
Conductor Screen
Insulation
Insulation Screen
Metallic Screen
Bedding
Jacketing

:
:
:
:
:
:
:
:
:

CU/XLPE/PVC, 3.6/6 KV
IEC 60502-2
Circular stranded Compacted copper (or Aluminum)
Bonded semiconducting material
XLPE material
Strippable semiconducting material (or Bonded)
Copper tape (or copper wires)
PVC compound (or LSHF or PE)
PVC compound (or LSHF or PE)

TECHNICAL INFORMATION
1. Weight and Dimension Data
Nominal
Cross
Section

Nominal
Insulation
Thickness

Nominal
Sheath
Thickness

Approx.
Overall
Diameter

Approx.
Cable
Weight

n x mm2

mm

mm

mm

kg/km

3 x 25
3 x 35
3 x 50
3 x 70
3 x 95
3 x 120
3 x 150
3 x 185
3 x 240
3 x 300
3 x 400
3 x 500

2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.6
2.8
3.0
3.2

2.1
2.2
2.3
2.4
2.5
2.6
2.7
2.8
3.0
3.2
3.5
3.7

39.8
42.7
45.5
49.6
53.0
56.9
60.4
64.6
70.1
75.4
83.6
90.3

1943
2360
2885
3649
4587
5484
6461
7635
9639
11806
14654
17897

2. Electrical Data
Cross section Area

mm2

16

25

35

50

70

95

120

150

185

240

300

400

500

16

16

16

16

16

16

16

25

25

25

25

35

35

W
/ km 1.150

0.727

0.524

0.387

0.268

0.193

0.153

0.124 0.0991 0.0754 0.0601 0.04700 0.0366

mm

Screen Area
o

DC Resist at 20 C
o

Ac Resist at 90 C

W
/ km 1.466

0.927

0.668

0.494

0.342

0.247

0.196

0.160 0.1290 0.099 0.0812

0.0657

0.0538

Inductance

mh/ km 0.422

0.402

0.379

0.422

0.330

0.310

0.300

0.290

0.280

0.270

0.266

0.261

0.256

Capacitance

m
F/ km 0.241

0.269

0.306

0.337

0.385

0.430

0.472

0.514

0.558

0.606

0.617

0.646

0.672

Charging current

A/ km

0.314

0.365

0.415

0.457

0.522

0.583

0.640

0.697

0.758

0.823

0.838

0.876

0.912

W/m

0.010

0.011

0.012

0.013

0.015

0.017

0.018

0.020

0.022

0.024

0.024

0.025

0.026

Cable in ground

115

160

191

224

255

300

340

385

435

495

555

625

700

Cable in free air

120

172

203

235

275

335

390

445

510

580

665

760

890

Conductor S.C (1 Sec)

KA

2.3

3.57

5.0

7.15

10.0

13.5

17.17

21.4

26.4

34.4

42.9

57.2

71.5

Screen S.C (1 Sec)

KA

2.29

2.29

2.29

2.29

2.29

2.29

2.29

3.58

3.58

3.58

3.58

5.07

5.07

Dielectic losses
Current Ampacity

Short circuit current

Medium Voltage Cables

15

Three Core Cable

For Installations outdoor in ground, in ducts and indoor on trays.


Type
Standard
Conductor
Conductor Screen
Insulation
Insulation Screen
Metallic Screen
Bedding
Armoring
Jacketing

:
:
:
:
:
:
:
:
:
:

CU/XLPE/STA/PVC, 3.6/6 KV
IEC 60502-2
Circular stranded Compacted copper (or Aluminum)
Bonded semiconducting material
XLPE material
Strippable semiconducting material (or Bonded)
Copper tape (or copper wires)
PVC compound (or LSHF or PE)
Galvanized steel tape
PVC compound (or LSHF or PE)

TECHNICAL INFORMATION
1. Weight and Dimension Data

Approx.
Overall
Diameter

Approx.
Cable
Weight

mm

mm

kg/ km

2.1
2.2
2.2
2.3
2.5
2.6
2.7
2.8
2.9
3.1
3.3
3.6
3.8

39.6
41.4
44.0
47.3
51.2
54.7
58.7
62.3
66.1
71.0
77.1
87.6
95.2

2097
2580
3014
4456
5449
6415
7444
8683
9420
10794
13069
16566
19895

Nominal
Cross
Section

Nominal
Insulation
Thickness

Steel
Tape
Thickness

Nominal
Sheath
Thickness

n x mm2

mm

mm

3x16
3x25
3x50
3x70
3x95
3x95
3x120
3x150
3x185
3x240
3x300
3x400
3x500

2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.6
2.8
3.0
3.2

0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.8
0.8

2. Electrical Data
Cross section Area

mm2

16

16

25

35

50

70

95

120

150

185

240

300

400

500

25

25

25

25

35

35

16

16

16

16

16

16

0.727

0.524

0.387

0.268

0.193

0.153

0.124 0.0991 0.0754 0.0601 0.0470 0.0366

Ac Resist at 90oC

W
/ km 1.150
W
/ km 1.466

0.927

0.668

0.494

0.342

0.247

0.196

0.160 0.1290 0.099 0.0812 0.0657 0.0538

Inductance

mh/ km 0.422

0.400

0.366

0.342

0.323

0.310

0.300

0.290

0.280

0.270

0.266

0.261

0.256

Capacitance

m
F/ km 0.241

0.269

0.306

0.337

0.385

0.430

0.472

0.514

0.558

0.606

0.617

0.646

0.672

Charging current

A/ km

0.314

0.365

0.415

0.457

0.522

0.583

0.640

0.697

0.758

0.823

0.838

0.876

0.912

Dielectic losses

W/m

0.010

0.011

0.012

0.013

0.015

0.017

0.018

0.020

0.022

0.024

0.024

0.025

0.026

Cable in ground

Cable in free air

114
120

157
170

187
198

219
230

248
281

297
335

336
390

379
445

425
495

485
575

540
650

612
745

680
860

2.3
2.29

3.57
2.29

5.0
2.29

7.15
2.29

10.0
2.29

13.5
2.29

17.17
2.29

21.4
3.58

26.4
3.58

34.4
3.58

42.9
3.58

57.2
5.07

71.5
5.07

mm

Screen Area
o

DC Resist at 20 C

Current Ampacity

Short circuit current

16

Conductor S.C (1 Sec)

KA

Screen S.C (1 Sec)

KA

Medium Voltage Cables

Three Core Cable

For Installations outdoor in ground, in ducts and indoor on trays.


Type
Standard
Conductor
Conductor Screen
Insulation
Insulation Screen
Metallic Screen
Armoring
Bedding
Jacketing

:
:
:
:
:
:
:
:
:
:

CU/XLPE/SWA/PVC, 3.6/6 KV
IEC 60502-2
Circular stranded Compacted copper (or Aluminum)
Bonded semiconducting material
XLPE material
Strippable semiconducting material (or Bonded)
Copper tape (or copper wires)
Galvanized steel Wire
PVC compound (or LSHF or PE)
PVC compound (or LSHF or PE)

TECHNICAL INFORMATION
1. Weight and Dimension Data
Nominal
Cross
Section

Nominal
Insulation
Thickness

Steel
Wire
Diameter

Nominal
Sheath
Thickness

Approx.
Overall
Diameter

Approx.
Cable
Weight

n x mm2

mm

mm

mm

mm

3x16
3x25
3x35
3x50
3x70
3x95
3x120
3x150
3x185
3x240
3x300
3x400
3x500

2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.6
2.8
3.0
3.2

2.00
2.00
2.50
2.50
2.50
2.50
2.50
2.50
2.50
3.15
3.15
3.15
3.15

2.2
2.3
2.3
2.5
2.6
2.8
2.8
2.9
3.1
3.2
3.5
3.7
4.0

40.9
43.5
46.6
49.8
53.9
58.0
64.9
65.4
69.9
75.5
82.8
89.9
98.4

kg/ km
2952
3404
3928
5037
5972
7084
8165
9273
10357
12938
16493
19858
23192

2. Electrical Data
Cross section Area

mm2

16

16

25

35

50

70

95

120

150

185

240

300

400

500

25

25

25

35

35

16

16

16

16

16

16

25

DC Resist at 20 C

W
/ km 1.150

0.727

0.524

0.387

0.268

0.193

0.153

0.124

0.0991 0.0754 0.0601 0.0470 0.0366

Ac Resist at 90oC

W
/ km 1.466

0.927

0.668

0.494

0.342

0.247

0.196

0.160

0.1290

0.099

0.0812 0.0657 0.0538

Inductance

mh/ km

0.422

0.400

0.366

0.342

0.323

0.309

0.296

0.288

0.280

0.270

0.266

0.261

0.256

Capacitance

m
F/ km 0.241

0.269

0.306

0.337

0.385

0.430

0.472

0.514

0.558

0.606

0.617

0.646

0.672

Charging current

A/ km

0.314

0.365

0.415

0.457

0.522

0.583

0.640

0.697

0.758

0.823

0.838

0.876

0.912

Dielectic losses

W/m

0.010

0.011

0.012

0.013

0.015

0.017

0.018

0.020

0.022

0.024

0.024

0.025

0.026

Cable in ground

Cable in free air

114
120

158
172

188
199

220
230

249
282

298
336

337
392

380
447

426
495

485
575

541
650

613
746

681
862

2.3
2.29

3.57
2.29

5.0
2.29

7.15
2.29

10.0
2.29

13.5
2.29

17.17
2.29

21.4
3.58

26.4
3.58

34.4
3.58

42.9
3.58

57.2
5.07

71.5
5.07

mm

Screen Area
o

Current Ampacity

Short circuit current


Conductor S.C (1 Sec)

KA

Screen S.C (1 Sec)

KA

Medium Voltage Cables

17

Single Core Cable

For Installations outdoor in ground, in ducts and indoor on trays.


Type
Standard
Conductor
Conductor Screen
Insulation
Insulation Screen
Metallic Screen
Jacketing

:
:
:
:
:
:
:
:

CU/XLPE/PVC, 6/10 KV
IEC 60502-2
Circular stranded Compacted copper (or Aluminum)
Bonded semiconducting material
XLPE material
Strippable semiconducting material (or Bonded)
Annealed Copper Wire (or Copper Tape)
PVC compound (or LSHF or PE)

TECHNICAL INFORMATION
1. Weight and Dimension Data
Nominal
Cross
Section

Nominal
Insulation
Thickness

Nominal
Sheath
Thickness

Approx.
Overall
Diameter

Approx.
Cable
Weight

n x mm2
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
1x400
1x500
1x630

mm
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4

mm
1.6
1.6
1.7
1.7
1.8
1.8
1.9
1.9
2.0
2.1
2.2
2.3
2.4

mm

kg/km

22.4
23.8
25.0
26.6
27.4
29.9
31.4
33.9
35.5
38.7
41.9
45.0
49.8

722
835
990
1211
1505
1752
2144
2495
3091
3706
4632
5605
7149

2. Electrical Data
Cross section Area

mm2

25

16

35

50

70

95

120

150

185

240

300

400

500

630

25

25

25

25

35

35

35

16

16

16

16

16

0.524

0.387

0.268

0.193

0.153

0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.0283

Ac Resist at 90oC

W
/ km 0.727
W
/ km 0.927

0.668

0.494

0.342

0.247

0.196

0.160 0.1290

0.099 0.0812 0.0657 0.0538 0.0452

Inductance
Flat Formation
Trefoil Formation

mh/ km 0.512
mh/ km 0.466

0.483
0.437

0.474
0.410

0.433
0.385

0.417
0.368

0.400
0.352

0.393
0.344

0.382
0.334

0.367
0.319

0.352
0.310

0.347
0.302

0.340
0.294

0.330
0.282

Capacitance

m
F/ km 0.213

0.240

0.264

0.299

0.332

0.363

0.394

0.427

0.479

0.520

0.577

0.636

0.711

Charging current

A/ km

0.482

0.544

0.596

0.676

0.751

0.822

0.892

0.966

1.083

1.176

1.306

1.439

1.607

Dielectic losses

W/m

0.023

0.026

0.029

0.032

0.036

0.039

0.043

0.046

0.052

0.056

0.063

0.069

0.077

Cable in ground

170

195

235

265

305

345

395

455

500

560

635

710

790

Cable in free air

180

210

245

285

355

410

470

540

630

720

840

960

1100

Conductor S.C (1 Sec)

KA

3.57

5.0

7.15

10.0

13.5

17.1

21.4

26.4

34.4

42.9

57.2

71.5

90.0

Screen S.C (1 Sec)

KA

2.29

2.29

2.29

2.29

2.29

2.29

3.58

2.29

3.58

3.58

5.07

5.07

5.07

mm

Screen Area
o

DC Resist at 20 C

Current Ampacity

Short circuit current

18

Medium Voltage Cables

Three Core Cable

For Installations outdoor in ground, in ducts and indoor on trays.


Type
Standard
Conductor
Conductor Screen
Insulation
Insulation Screen
Metallic Screen
Bedding
Jacketing

:
:
:
:
:
:
:
:
:

CU/XLPE/PVC, 6/10 KV
IEC 60502-2
Circular stranded Compacted copper (or Aluminum)
Bonded semiconducting material
XLPE material
Strippable semiconducting material (or Bonded)
Copper tape (or copper wires)
PVC compound (or LSHF or PE)
PVC compound (or LSHF or PE)

TECHNICAL INFORMATION

1. Weight and Dimension Data


Nominal
Cross
Section

Nominal
Insulation
Thickness

Nominal
Sheath
Thickness

Approx.
Overall
Diameter

Approx.
Cable
Weight

n x mm2
3x16
3x25
3x35
3x50
3x70
3x95
3x120
3x150
3x185
3x240
3x300
3x400
3x500

mm
3.4
3.3
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4

mm
2.2
2.2
2.3
2.4
2.5
2.7
2.8
2.9
3.0
3.1
3.3
3.5
3.7

mm
41.1
43.2
46.5
49.2
53.0
57.2
60.5
64.1
66.9
73.0
78.5
85.1
91.6

kg/km
1807
2213
2686
3181
3973
5012
5877
6876
8073
10112
12121
14860
18013

2. Electrical Data
Cross section Area

mm2

16

16

25

35

50

70

95

120

150

185

240

300

400

500

25

25

25

35

35

16

16

16

16

16

16

25

0.727

0.524

0.387

0.268

0.193

0.153

0.124

0.0991 0.0754 0.0601 0.0470 0.0366

Ac Resist at 90oC

W
/ km 1.150
W
/ km 1.466

0.927

0.668

0.494

0.342

0.247

0.196

0.160

0.1291 0.099 0.0814 0.0659 0.0543

Inductance

mh/ km 0.447

0.413

0.387

0.362

0.341

0.325

0.312

0.302

0.300

0.280

0.274

0.265

0.259

Capacitance

m
F/ km 0.192

0.213

0.240

0.264

0.299

0.332

0.363

0.394

0.427

0.479

0.520

0.577

0.636

Charging current

A/ km

0.314

0.482

0.544

0.596

0.676

0.751

0.822

0.892

0.966

1.083

1.176

1.306

1.439

W/m

0.019

0.023

0.026

0.029

0.032

0.036

0.039

0.043

0.046

0.052

0.056

0.063

0.069

Cable in ground

Cable in free air

115
120

161
173

180
199

210
230

253
275

302
335

340
390

387
447

430
505

493
578

555
665

628
758

700
890

2.3
2.29

3.57
2.29

5.0
2.29

7.15
2.29

10.0
2.29

13.5
2.29

17.17
2.29

21.4
3.58

26.4
3.58

34.4
3.58

42.9
3.58

57.2
5.07

71.5
5.07

mm

Screen Area
o

DC Resist at 20 C

Dielectic losses
Current Ampacity

Short circuit current


Conductor S.C (1 Sec)

KA

Screen S.C (1 Sec)

KA

Medium Voltage Cables

19

Three Core Cable

For Installations outdoor in ground, in ducts and indoor on trays.


Type
Standard
Conductor
Conductor Screen
Insulation
Insulation Screen
Metallic Screen
Bedding
Armoring
Jacketing

:
:
:
:
:
:
:
:
:
:

CU/XLPE/ STA/ PVC, 6/10 KV


IEC 60502-2
Circular stranded Compacted copper (or Aluminum)
Bonded semiconducting material
XLPE material
Strippable semiconducting material (or Bonded)
Copper tape (or copper wire)
PVC compound (or LSHF or PE)
Galvanized steel tape
PVC compound (or LSHF or PE)

TECHNICAL INFORMATION
1. Weight and Dimension Data
Nominal
Cross
Section

Nominal
Insulation
Thickness

Steel
Tape
Thickness

Nominal
Sheath
Thickness

Approx.
Overall
Diameter

Approx.
Cable
Weight

n x mm2
3x16
3x25
3x35
3x50
3x70
3x95
3x120
3x150
3x185
3x240
3x300
3x400
3x500

mm
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4

mm
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5

mm
2.3
2.4
2.4
2.5
2.6
2.7
2.8
2.9
3.1
3.2
3.4
3.6
3.8

mm
43.1
45.4
48.0
51.3
55.2
59.4
62.7
66.0
69.0
76.2
79.9
88.4
95.0

kg/ km
2423
2910
3439
3992
4843
5921
6850
7902
9163
11341
13440
17082
20399

2. Electrical Data
Cross section Area

mm2

16

16

25

35

50

70

95

120

150

185

240

300

400

500

25

25

25

25

35

35

16

16

16

16

16

16

0.727

0.524

0.387

0.268

0.193

0.153

0.124 0.0991 0.0754 0.0601 0.0470 0.0366

Ac Resist at 90oC

W
/ km 1.150
W
/ km 1.466

0.927

0.668

0.494

0.342

0.247

0.196

0.160 0.1291 0.099 0.0814 0.0659 0.0543

Inductance

mh/ km

0.447

0.413

0.387

0.362

0.341

0.326

0.312

0.302

0.300

0.281

0.274

0.265

0.259

Capacitance

m
F/ km 0.192

0.213

0.240

0.264

0.299

0.332

0.363

0.394

0.427

0.479

0.520

0.577

0.636

Charging current

A/ km

0.569

0.482

0.544

0.596

0.676

0.751

0.822

0.892

0.966

1.038

1.176

1.306

1.439

Dielectic losses

W/m

0.019

0.023

0.026

0.029

0.032

0.036

0.039

0.043

0.046

0.054

0.056

0.063

0.069

Cable in ground

Cable in free air

115
125

159
172

175
195

205
232

250
232

295
340

335
390

380
446

420
495

482
570

540
650

612
745

682
863

2.3
2.29

3.57
2.29

5.0
2.29

7.15
2.29

10.0
2.29

13.5
2.29

17.11
2.29

21.4
3.58

26.4
3.58

34.3
3.58

42.9
3.58

57.2
5.07

71.5
5.07

mm

Screen Area
o

DC Resist at 20 C

Current Ampacity

Short circuit current


Conductor S.C (1 Sec)

KA

Screen S.C (1 Sec)

KA

20 Medium Voltage Cables

Three Core Cable

For Installations outdoor in ground and ducts, and indoor on trays, in walls, and in ducts.
Type
Standard
Conductor
Conductor Screen
Insulation
Insulation Screen
Metallic Screen
Bedding
Armoring
Jacketing

:
:
:
:
:
:
:
:
:
:

CU/XLPE/SWA/PVC, 6/10 KV
IEC 60502-2
Circular stranded Compacted copper (or Aluminum)
Bonded semiconducting material
XLPE material
Strippable semiconducting material (or Bonded)
Copper tape (or copper wire)
PVC compound (or LSHF or PE)
Galvanized steel wires
PVC compound (or LSHF or PE)

TECHNICAL INFORMATION
1. Weight and Dimension Data
Nominal
Cross
Section

Nominal
Insulation
Thickness

Steel
Wire
Diameter

Nominal
Sheath
Thickness

Approx.
Overall
Diameter

Approx.
Cable
Weight

n x mm2

mm

mm

mm

mm

kg/ km

3x16
3x25
3x35
3x50
3x70
3x95
3x120
3x150
3x185
3x240
3x300
3x400
3x500

3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4
3.4

2.00
2.00
2.50
2.50
2.50
2.50
2.50
2.50
2.50
3.15
3.15
3.15
3.15

2.4
2.4
2.6
2.7
2.8
2.8
2.9
3.0
3.2
3.4
3.6
3.8
4.0

45.7
49.0
51.4
54.5
58.9
62.8
65.6
70.7
73.5
81.4
87.0
92.5
99.6

3415
4293
4904
5535
6492
7684
8728
9897
11308
14832
17097
20268
23783

2. Electrical Data
Cross section Area

mm2

16

16

25

35

50

70

95

120

150

185

240

300

400

500

25

25

25

25

35

35

16

16

16

16

16

16

0.727

0.524

0.387

0.268

0.193

0.153

0.124 0.0991 0.0754 0.0601 0.0470 0.0366

Ac Resist at 90oC

W
/ km 1.150
W
/ km 1.466

0.927

0.668

0.494

0.342

0.247

0.196

0.160 0.1290 0.0999 0.0814 0.0659 0.0543

Inductance

mh/ km 0.447

0.413

0.387

0.362

0.341

0.326

0.312

0.302

0.294

0.281

0.274

0.265

0.259

Capacitance

m
F/ km 0.192

0.213

0.240

0.264

0.299

0.332

0.363

0.394

0.427

0.479

0.520

0.577

0.636

Charging current

A/ km

0.314

0.482

0.544

0.596

0.676

0.751

0.822

0.892

0.966

1.083

1.176

1.306

1.439

W/m

0.019

0.023

0.026

0.029

0.032

0.036

0.039

0.043

0.046

0.052

0.056

0.063

0.069

Cable in ground

Cable in free air

115
125

160
172

175
199

205
230

245
285

295
336

330
392

375
446

418
487

470
568

525
635

590
735

640
820

2.3
2.29

3.57
2.29

5.0
2.29

7.15
2.29

10.0
2.29

13.5
2.29

17.11
2.29

21.4
3.58

26.4
3.58

34.3
3.58

42.9
3.58

57.2
5.07

71.5
5.07

mm

Screen Area
o

DC Resist at 20 C

Dielectic losses
Current Ampacity

Short circuit current


Conductor S.C (1 Sec)

KA

Screen S.C (1 Sec)

KA

Medium Voltage Cables

21

Single Core Cable

For Installations outdoor in ground, in ducts and indoor on trays.


Type
Standard
Conductor
Conductor Screen
Insulation
Insulation Screen
Metallic Screen
Jacketing

CU/XLPE/PVC, 8.7/15 KV
IEC 60502-2
Circular stranded Compacted copper (or Aluminum)
Bonded semiconducting material
XLPE material
Strippable semiconducting material (or Bonded)
Annealed Copper Wires (or LSHF or PE)
PVC compound (or LSHF or PE)

:
:
:
:
:
:
:
:

TECHNICAL INFORMATION
1. Weight and Dimension Data
Nominal
Cross
Section

Nominal
Insulation
Thickness

Nominal
Sheath
Thickness

Approx.
Overall
Diameter

Approx.
Cable
Weight

n x mm2
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
1x400
1x500
1x630

mm
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5

mm
1.7
1.7
1.7
1.8
1.8
1.9
2.0
2.0
2.1
2.2
2.3
2.4
2.5

mm
24.4
25.6
26.0
28.5
30.2
31.2
34.0
35.2
38.5
40.6
43.1
47.3
51.1

kg/km
797
915
1054
1293
1586
1857
2255
2537
3214
3848
4774
5766
7324

2. Electrical Data
Cross section Area

mm2

25

16

35

50

70

95

120

150

185

240

300

400

500

630

25

25

25

25

35

35

35

16

16

16

16

16

DC Resist at 20 C

W
/ km 0.727

0.524

0.387

0.268

0.193

0.153

0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.0283

Ac Resist at 90oC

W
/ km 0.927

0.668

0.495

0.342

0.247

0.196

0.160 0.1286 0.0992 0.0806 0.0651 0.0532 0.0455

Inductance
Flat Formation
Trefoil Formation

mh/ km 0.534

0.504

0.475

0.451

0.432

0.416

0.407

0.396

0.380

0.371

0.361

0.352

0.339

mh/ km 0.486

0.457

0.427

0.402

0.394

0.386

0.358

0.348

0.332

0.322

0.314

0.304

0.291

Capacitance

m
F/ km 0.175

0.196

0.213

0.240

0.266

0.289

0.313

0.338

0.377

0.408

0.452

0.496

0.553

Charging current

A/ km

0.572

0.641

0.699

0.788

0.871

0.949

1.026

1.108

1.236

1.339

1.481

1.628

1.813

W/m

0.040

0.045

0.049

0.055

0.061

0.066

0.071

0.077

0.086

0.093

0.103

0.113

0.126

150
165

180

210

255

305

345

390

430

500

560

635

710

790

200

240

300

360

415

475

540

635

730

840

960

1100

3.57
2.29

5.0

7.15

10.0

13.5

17.1

21.4

26.4

34.4

42.9

57.2

71.5

90.0

2.29

2.29

2.29

2.29

2.29

3.58

2.29

3.58

3.58

5.07

5.07

5.07

mm

Screen Area
o

Dielectic losses
Current Ampacity
Cable in ground

Cable in free air


Short circuit current

22

Conductor S.C (1 Sec)

KA

Screen S.C (1 Sec)

KA

Medium Voltage Cables

Three Core Cable

For Installations outdoor in ground, in ducts and indoor on trays.


Type
Standard
Conductor
Conductor Screen
Insulation
Insulation Screen
Metallic Screen
Bedding
Jacketing

:
:
:
:
:
:
:
:
:

CU/XLPE/PVC, 8.7/15 KV
IEC 60502-2
Circular stranded Compacted copper (or Aluminum)
Bonded semiconducting material
XLPE material
Strippable semiconducting material (or Bonded)
Copper Tape (or Copper Tape)
PVC compound (or LSHF or PE)
PVC compound (or LSHF or PE)

TECHNICAL INFORMATION
1. Weight and Dimension Data
Nominal
Cross
Section

Nominal
Insulation
Thickness

Nominal
Sheath
Thickness

Approx.
Overall
Diameter

Approx.
Cable
Weight

n x mm2
1x25
1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
1x400
1x500

mm
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5

mm
2.4
2.5
2.6
2.7
2.8
2.9
3.0
3.1
3.3
3.5
3.7
3.9

mm
48.0
51.1
54.1
58.5
62.2
64.8
69.1
73.1
78.0
82.9
90.1
37.2

kg/km
2633
3080
3604
4473
5462
6343
7361
8660
10701
12752
15547
18821

2. Electrical Data
Cross section Area

mm2

25

35

50

70

16

16

16

16

16

16

25

0.153

0.124

0.0991 0.0754 0.0601 0.0470 0.0366

mm

Screen Area

95

120

150

185

240

300

400

500

25

25

25

35

35

0.524

0.387

0.268

0.193

Ac Resist at 90oC

W
/ km 0.727
W
/ km 0.927

0.668

0.494

0.342

0.247

0.196

0.160

0.1288 0.0995 0.0810 0.0655 0.0538

Inductance

mh/ km 0.438

0.411

0.384

0.360

0.345

0.330

0.319

0.309

0.296

0.287

0.278

0.270

Capacitance

m
F/ km 0.175

0.196

0.213

0.240

0.266

0.289

0.313

0.338

0.377

0.408

0.452

0.496

Charging current

A/ km

0.572

0.641

0.699

0.788

0.871

0.949

1.026

1.108

1.236

1.339

1.481

1.628

Dielectic losses

W/m

0.040

0.045

0.049

0.055

0.061

0.066

0.071

0.077

0.086

0.093

0.103

0.113

Cable in ground

Cable in free air

148
160

175
195

205
230

250
280

300
340

340
390

380
440

425
505

493
585

555
665

630
765

695
885

3.57
2.29

5.0
2.29

7.15
2.29

10.0
2.29

13.5
2.29

17.1
2.29

21.4
3.58

26.4
3.58

34.3
3.58

42.9
3.58

57.2
5.07

71.5
5.07

DC Resist at 20 C

Current Ampacity

Short circuit current


Conductor S.C (1 Sec)

KA

Screen S.C (1 Sec)

KA

Medium Voltage Cables

23

Three Core Cable

For Installations outdoor in ground, in ducts and indoor on trays.


Type
Standard
Conductor
Conductor Screen
Insulation
Insulation Screen
Metallic Screen
Bedding
Armoring
Jacketing

:
:
:
:
:
:
:
:
:
:

CU/XLPE/STA/PVC, 8.7/15 KV
IEC 60502-2
Circular stranded Compacted copper (or Aluminum)
Bonded semiconducting material
XLPE material
Strippable semiconducting material (or Bonded)
Copper tape
PVC compound (or LSHF or PE)
Galvanized Steel Tape
PVC compound (or LSHF or PE)

TECHNICAL INFORMATION
1. Weight and Dimension Data
Nominal
Cross
Section

Nominal
Insulation
Thickness

Steel
Tape
Thickness

Nominal
Sheath
Thickness

Approx.
Overall
Diameter

Approx.
Cable
Weight

n x mm2
3x25
3x35
3x50
3x70
3x95
3x120
3x150
3x185
3x240
3x300
3x400
3x500

mm
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5

mm
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.8
0.8
0.8

mm
2.5
2.6
2.7
2.8
2.9
3.0
3.1
3.2
3.4
3.6
3.8
4.0

mm
50.2
53.3
56.6
60.1
64.5
67.2
71.3
75.4
81.1
87.3
93.5
99.9

kg/ km
3447
3946
4509
5460
6508
7449
8527
9901
12038
14953
17922
21393

2. Electrical Data
Cross section Area

mm2

25

35

50

70

16

16

16

16

16

16

25

0.153

0.124

0.0991 0.0754 0.0601 0.0470 0.0366

mm

Screen Area

95

120

150

185

240

300

400

500

25

25

25

35

35

0.524

0.387

0.268

0.193

Ac Resist at 90o

W
/ km 0.727
W
/ km 0.927

0.668

0.494

0.342

0.247

0.196

0.160

0.1288 0.0995 0.0810 0.0655 0.0538

Inductance

mh/ km 0.438

0.411

0.384

0.360

0.345

0.330

0.319

0.309

0.296

0.287

0.278

0.270

Capacitance

m
F/ km 0.175

0.196

0.213

0.240

0.266

0.289

0.313

0.338

0.377

0.408

0.452

0.496

Charging current

A/ km

0.572

0.641

0.699

0.788

0.871

0.949

1.026

1.108

1.236

1.339

1.481

1.628

W/m

0.040

0.045

0.049

0.055

0.061

0.066

0.071

0.077

0.086

0.093

0.103

0.113

146
160

175
195

205
232

245
285

295
345

330
395

370
450

415
500

482
590

540
660

610
750

675
860

3.57
2.29

5.0
2.29

7.15
2.29

10.0
2.29

13.5
2.29

17.1
2.29

21.4
3.58

26.4
3.58

34.3
3.58

42.9
3.58

57.2
5.07

71.5
5.07

DC Resist at 20 C

Dielectic losses
Current Ampacity
Cable in ground
Cable in free air

Short circuit current

24

Conductor S.C (1 Sec)

KA

Screen S.C (1 Sec)

KA

Medium Voltage Cables

Three Core Cable

For Installations outdoor in ground, in ducts and indoor on trays.


Type
Standard
Conductor
Conductor Screen
Insulation
Insulation Screen
Metallic Screen
Bedding
Armoring
Jacketing

:
:
:
:
:
:
:
:
:
:

CU/XLPE/SWA/PVC, 8.7/15 KV
IEC 60502-2
Circular stranded Compacted copper (or Aluminum)
Bonded semiconducting material
XLPE material
Strippable semiconducting material (or Bonded)
Copper tape
PVC compound (or LSHF or PE)
Galvanized Steel Wires
PVC compound (or LSHF or PE)

TECHNICAL INFORMATION
1. Weight and Dimension Data
Nominal
Cross
Section

Nominal
Insulation
Thickness

n x mm2

mm

3x25
3x35
3x50
3x70
3x95
3x120
3x150
3x185
3x240
3x300
3x400
3x500

4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5
4.5

Steel
Wire
Diameter

Nominal
Sheath
Thickness

mm

mm

2.50
2.50
2.50
2.50
2.50
2.50
3.15
3.15
3.15
3.15
3.15
3.15

2.6
2.7
2.8
2.9
3.0
3.1
3.2
3.4
3.6
3.7
4.0
4.1

Approx.
Overall
Diameter

Approx.
Cable
Weight

mm

kg/ km

54.2
57.3
59.4
64.0
66.9
71.2
74.6
81.3
86.1
91.0
98.2
104.2

4942
5559
6169
7261
8425
9445
10638
13322
15731
18030
21248
24919

2. Electrical Data
Cross section Area

mm2

25

16

mm

Screen Area

35

50

70

95

120

150

185

240

300

400

500

25

25

25

35

35

16

16

16

16

16

25

0.524

0.387

0.268

0.193

0.153

0.124

0.0991 0.0754 0.0601 0.0470 0.0366

0.668

0.494

0.342

0.247

0.196

0.160

0.1288 0.0995 0.0810 0.0655 0.0538

0.330

0.319

0.309

0.296

0.287

0.278

0.270

Ac Resist at 90oC

W
/ km 0.727
W
/ km 0.927

Inductance

mh/ km 0.438

0.411

0.384

0.360

0.345

Capacitance

m
F/ km 0.175

0.196

0.213

0.240

0.266

0.289

0.313

0.338

0.377

0.408

0.452

0.496

Charging current

A/ km

0.572

0.641

0.699

0.788

0.871

0.949

1.026

1.108

1.236

1.339

1.481

1.628

Dielectic losses

W/m

0.040

0.045

0.049

0.055

0.061

0.066

0.071

0.077

0.086

0.093

0.103

0.113

Cable in ground

Cable in free air

160
172

175
199

205
235

245
285

295
345

333
395

370
445

415
505

470
570

525
635

640
735

690
820

5
2.29

5.0
2.29

7.15
2.29

10.0
2.29

13.5
2.29

17.1
2.29

21.4
3.58

26.47
3.58

34.4
3.58

42.9
3.58

57.2
5.07

71.5
5.07

DC Resist at 20 C

Current Ampacity

Short circuit current


Conductor S.C (1 Sec)

KA

Screen S.C (1 Sec)

KA

Medium Voltage Cables

25

Single Core Cable

For Installations outdoor in ground, in ducts and indoor on trays.


Type
Standard
Conductor
Conductor Screen
Insulation
Insulation Screen
Metallic Screen
Jacketing

:
:
:
:
:
:
:
:

CU/XLPE/PVC, 12/20 KV
IEC 60502-2
Circular stranded Compacted copper (or Aluminum)
Bonded semiconducting material
XLPE material
Strippable semiconducting material (or Bonded)
Annealed Copper wires (or Copper Tape)
PVC compound (or LSHF or PE)

TECHNICAL INFORMATION
1. Weight and Dimension Data
Nominal
Cross
Section
n x mm2

Nominal
Insulation
Thickness
mm

Nominal
Sheath
Thickness
mm

Approx.
Overall
Diameter
mm

Approx.
Cable
Weight
kg/km

1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
1x400
1x500
1x630

5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5

1.8
1.8
1.9
1.9
2.0
2.0
2.1
2.2
2.2
2.3
2.4
2.5

27.5
28.6
30.6
32.8
34.5
36.6
37.6
41.0
42.9
45.6
48.4
53.5

1024
1171
1424
1710
1984
2368
2721
3370
3981
4932
5911
7504

2. Electrical Data
Cross section Area

mm2

35

50

70

95

120

150

185

240

300

400

500

630

Screen Area

mm2

16

16

16

16

16

25

25

25

25

35

35

35

W
/ km 0.524
W
/ km 0.668

0.387

0.268

0.193

0.153

0.124 0.0991 0.0754 0.0601 0.0470 0.366 0.0283

0.494

0.342

0.247

0.196

0.160 0.1286 0.0990 0.0806 0.0641 0.0530 0.0440

Inductance
Flat Formation
Trefoil Formation

mh/ km 0.521

0.491

0.466

0.446

0.429

0.419

0.408

0.391

0.380

0.370

0.358

mh/ km 0.472

0.443

0.417

0.398

0.381

0.371

0.359

0.343

0.333

0.323

0.310

0.300

Capacitance

m
F/ km 0.170

0.185

0.207

0.228

0.247

0.267

0.287

0.319

0.345

0.381

0.417

0.464

Charging current

A/ km

2.089
0.201

DC Resist at 20 C
o

Ac Resist at 90 C

0.347

W/m

0.769
0.074

0.835
0.080

0.936
0.090

1.031
0.099

1.119
0.107

1.207
0.116

1.300
0.125

1.445
0.139

1.561
0.150

1.723
0.165

1.889
0.181

Cable in ground

175

210

255

305

345

385

430

500

560

630

710

795

Cable in free air

200

240

300

360

415

475

540

640

730

840

960

1105

Dielectic losses
Current Ampacity

Short circuit current

26

Conductor S.C (1 Sec)

KA

5.0

7.15

10.0

13.5

17.1

21.4

26.4

34.4

42.9

57.2

71.5

90.0

Screen S.C (1 Sec)

KA

2.29

2.29

2.29

2.29

2.29

3.58

3.58

3.58

3.58

5.07

5.07

5.07

Medium Voltage Cables

Three Core Cable

For Installations outdoor in ground, in ducts and indoor on trays.


Type
Standard
Conductor
Conductor Screen
Insulation
Insulation Screen
Metallic Screen
Jacketing

:
:
:
:
:
:
:
:

CU/XLPE/PVC, 12/20 KV
IEC 60502-2
Circular stranded Compacted copper (or Aluminum)
Bonded semiconducting material
XLPE material
Strippable semiconducting material (or Bonded)
Copper tape (or Copper Wire)
PVC compound (or LSHF or PE)

TECHNICAL INFORMATION
1. Weight and Dimension Data
Nominal
Cross
Section

Nominal
Insulation
Thickness

Nominal
Sheath
Thickness

Approx.
Overall
Diameter

Approx.
Cable
Weight

n x mm2

mm

mm

mm

kg/km

3x35
3x50
3x70
3x95
3x120
3x150
3x185
3x240
3x300
3x400

5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5

2.6
2.7
2.8
3.0
3.1
3.2
3.3
3.5
3.6
3.9

56.6
59.5
63.1
66.5
70.3
74.4
76.9
82.9
88.1
95.0

3539
4075
4908
5954
6858
7986
9229
11303
13345
16276

2. Electrical Data
Cross section Area

mm2

35

50

70

16

16

16

16

16
0.153

0.124 0.0991 0.0754 0.0601 0.0470

mm

Screen Area

95

120

150

185

240

300

400

25

25

25

25

35

DC Resist at 20 C

W
/ km 0.524

0.387

0.268

0.193

Ac Resist at 90oC

W
/ km 0.668

0.402

0.342

0.247

0.196

0.160 0.1286 0.0993 0.0806 0.0652

Inductance

mh/ km 0.429

0.410

0.378

0.361

0.344

0.333

0.323

0.308

0.299

0.289

Capacitance

m
F/ km 0.170

0.185

0.207

0.228

0.247

0.267

0.287

0.319

0.345

0.381

Charging current

A/ km

0.769

0.835

0.936

1.031

1.119

1.207

1.300

1.445

1.561

1.723

W/m

0.074

0.080

0.090

0.099

0.107

0.116

0.125

0.139

0.150

0.165

Cable in ground

Cable in free air

175
195

205
240

250
285

300
350

340
395

380
450

425
510

490
600

555
680

625
775

5.0
2.29

7.15
2.29

10.0
2.29

13.5
2.29

17.1
2.29

21.4
3.58

26.4
3.58

34.4
3.58

42.9
3.58

57.2
5.07

Dielectic losses
Current Ampacity

Short circuit current


Conductor S.C (1 Sec)

KA

Screen S.C (1 Sec)

KA

Medium Voltage Cables

27

Three Core Cable

For Installations outdoor in ground, in ducts and indoor on trays.


Type
Standard
Conductor
Conductor Screen
Insulation
Insulation Screen
Metallic Screen
Bedding
Armoring
Jacketing

:
:
:
:
:
:
:
:
:
:

CU/XLPE/STA/PVC, 12/20 KV
IEC 60502-2
Circular stranded Compacted copper (or Aluminum)
Bonded semiconducting material
XLPE material
Strippable semiconducting material (or Bonded)
Copper tape
PVC compound (or LSHF or PE)
Galvanized Steel Tape
PVC compound (or LSHF or PE)

TECHNICAL INFORMATION
1. Weight and Dimension Data
Nominal
Cross
Section

Nominal
Insulation
Thickness

Steel
Tape
Thickness

Nominal
Sheath
Thickness

Approx.
Overall
Diameter

Approx.
Cable
Weight

n x mm2
3x35
3x50
3x70
3x95
3x120
3x150
3x185
3x240
3x300
3x400

mm

mm

mm

mm

kg/ km

5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5

0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5
0.5

2.7
2.8
2.9
3.0
3.1
3.3
3.4
3.6
3.7
4.0

58.0
61.5
65.4
68.0
72.4
76.5
80.0
87.1
91.5
98.6

4454
5032
5933
7011
7972
9204
10507
13463
15632
18797

2. Electrical Data
Cross section Area

mm2

35

16

50

70

95

120

150

185

240

300

400

16

16

16

16

25

25

25

25

35

W
/ km 0.524

0.387

0.268

0.193

0.153

0.124

0.0991

0.0754

0.0601

0.0470

Ac Resist at 90oC

W
/ km 0.668

0.494

0.342

0.247

0.196

0.160

0.1286

0.0992

0.0806

0.0652

Inductance

mh/ km

0.429

0.402

0.378

0.361

0.350

0.333

0.323

0.308

0.300

0.289

Capacitance

m
F/ km 0.170

0.185

0.207

0.228

0.247

0.267

0.287

0.319

0.345

0.381

Charging current

A/ km

0.769

0.835

0.936

1.031

1.119

1.207

1.300

1.445

1.561

1.723

W/m

0.074

0.080

0.090

0.099

0.107

0.116

0.125

0.139

0.150

0.165

Cable in ground

Cable in free air

175
195

205
240

245
285

295
350

330
395

370
450

415
500

485
590

540
685

610
750

5.0
2.29

7.15
2.29

10.0
2.29

13.5
2.29

17.1
2.29

21.4
3.58

26.4
3.58

34.4
3.58

42.9
3.58

57.2
5.07

mm

Screen Area
o

DC Resist at 20 C

Dielectic losses
Current Ampacity

Short circuit current

28

Conductor S.C (1 Sec)

KA

Screen S.C (1 Sec)

KA

Medium Voltage Cables

Three Core Cable

For Installations outdoor in ground, in ducts and indoor on trays.


Type
Standard
Conductor
Conductor Screen
Insulation
Insulation Screen
Metallic Screen
Bedding
Armoring
Jacketing

CU/XLPE/SWA/PVC, 12/20 KV
IEC 60502-2
Circular stranded Compacted copper (or Aluminum)
Bonded semiconducting material
XLPE material
Strippable semiconducting material (or Bonded)
Copper tape (or Copper Wires)
PVC compound (or LSHF or PE)
Galvanized Steel Wires
PVC compound (or LSHF or PE)

:
:
:
:
:
:
:
:
:
:

TECHNICAL INFORMATION
1. Weight and Dimension Data
Nominal
Cross
Section

Nominal
Insulation
Thickness

Steel
Wire
Diameter

Nominal
Sheath
Thickness

Approx.
Overall
Diameter

Approx.
Cable
Weight

n x mm2

mm

mm

mm

mm

kg/ km

3x35
3x50
3x70
3x95
3x120
3x150
3x185
3x240
3x300
3x400

5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5

2.50
2.50
2.50
2.50
2.50
3.15
3.15
3.15
3.15
3.15

2.8
3.0
3.0
3.1
3.3
3.4
3.6
3.7
3.8
4.1

62.2
64.7
68.6
72.3
75.0
81.2
85.0
91.6
96.1
102.1

6199
6862
7873
9069
10146
12635
14146
16545
18864
22248

2. Electrical Data
Cross section Area

mm2

35

16

DC Resist at 20 C
Ac Resist at 90oC
Inductance

70

95

120

150

185

240

300

400

16

16

16

16

25

25

25

25

35

W
/ km 0.524

0.387

0.268

0.193

0.153

0.124

0.0991

0.0754

0.0601

0.0470

W
/ km 0.668

0.494

0.342

0.247

0.196

0.159

0.1286

0.0992

0.0806

0.0652

0.350

0.333

0.323

0.308

0.300

0.289

mm

Screen Area

50

0.430

0.402

0.378

0.361

Capacitance

m
F/ km 0.170

0.185

0.207

0.228

0.247

0.267

0.287

0.319

0.345

0.381

Charging current

A/ km

0.769

0.835

0.936

1.031

1.119

1.207

1.300

1.445

1.561

1.723

W/m

0.074

0.080

0.090

0.099

0.107

0.116

0.125

0.139

0.150

0.165

Cable in ground

Cable in free air

175
200

205
235

245
290

295
350

330
400

370
450

410
500

470
590

520
660

585
725

5.0
2.29

7.15
2.29

10.0
2.29

13.5
2.29

17.1
2.29

21.4
3.58

26.4
3.58

34.4
3.58

42.9
3.58

57.2
5.07

Dielectic losses

mh/ km

Current Ampacity

Short circuit current


Conductor S.C (1 Sec)

KA

Screen S.C (1 Sec)

KA

Medium Voltage Cables

29

Single Core Cable

For Installations outdoor in ground, in ducts and indoor on trays.


Type
Standard
Conductor
Conductor Screen
Insulation
Insulation Screen
Metallic Screen
Bedding
Jacketing

:
:
:
:
:
:
:
:
:

CU/XLPE/PVC, 18/30 KV
IEC 60502-2
Circular stranded Compacted copper (or Aluminum)
Bonded semiconducting material
XLPE material
Strippable semiconducting material (or Bonded)
Copper wires (or Copper Tape)
PVC compound (or LSHF or PE)
PVC compound (or LSHF or PE)

TECHNICAL INFORMATION
1. Weight and Dimension Data
Nominal
Insulation
Thickness

Nominal
Sheath
Thickness

Approx.
Overall
Diameter

Approx.
Cable
Weight

n x mm2

mm

kg/km

8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0

mm
1.9
2.0
2.0
2.1
2.1
2.2
2.2
2.3
2.4
2.5
2.6
2.7

mm

1x35
1x50
1x70
1x95
1x120
1x150
1x185
1x240
1x300
1x400
1x500
1x630

32.1
34.4
35.2
37.1
39.4
41.6
43.2
45.5
47.2
51.6
54.5
59.3

1253
1431
1680
2000
2264
2683
3066
3707
4357
5324
6345
7963

Nominal
Cross
Section

2. Electrical Data
Cross section Area

mm2

35

16

50

70

16

95

120

150

185

240

300

400

500

630

25

25

25

25

35

35

35

16

16

16

0.387

0.268

0.193

0.153

0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.0283

Ac Resist at 90oC

W
/ km 0.524
W
/ km 0.668

0.494

0.342

0.247

0.196

0.160 0.1286 0.0990 0.0806 0.0641 0.0530 0.0440

Inductance
Flat Formation
Trefoil Formation

mh/ km 0.555
mh/ km 0.509

0.525
0.477

0.497
0.450

0.477
0.429

0.458
0.411

0.447
0.399

0.433
0.386

0.414
0.368

0.404
0.356

0.393
0.343

0.381
0.332

0.366
0.320

Capacitance

m
F/ km 0.133

0.143

0.159

0.174

0.192

0.201

0.216

0.238

0.256

0.281

0.306

0.340

Charging current

A/ km

0.903

0.974

1.081

1.181

1.274

1.366

1.464

1.161

1.737

1.906

2.600

2.300

W/m

0.130

0.140

0.156

0.170

0.183

0.197

0.221

0.233

0.250

0.270

0.300 0.330

Cable in ground

176

210

257

305

346

387

432

500

563

630

712

795

Cable in free air

205

243

305

368

419

479

545

645

732

845

965

1105

mm

Screen Area
o

DC Resist at 20 C

Dielectic losses
Current Ampacity

Short circuit current

30

Conductor S.C (1 Sec)

KA

5.0

7.15

10.0

13.5

17.1

21.4

26.4

34.4

42.9

57.2

71.5

90.0

Screen S.C (1 Sec)

KA

2.29

2.29

2.29

2.29

2.29

3.58

3.58

3.58

3.58

5.07

5.07

5.07

Medium Voltage Cables

Three Core Cable

For Installations outdoor in ground, in ducts and indoor on trays.


Type
Standard
Conductor
Conductor Screen
Insulation
Insulation Screen
Metallic Screen
Bedding
Jacketing

:
:
:
:
:
:
:
:
:

CU/XLPE/PVC, 18/30 KV
IEC 60502-2
Circular stranded Compacted copper (or Aluminum)
Bonded semiconducting material
XLPE material
Strippable semiconducting material (or Bonded)
Copper tape (or Copper Wire)
PVC compound (or LSHF or PE)
PVC compound (or LSHF or PE)

TECHNICAL INFORMATION
1. Weight and Dimension Data
Nominal
Cross
Section

Nominal
Insulation
Thickness

Nominal
Sheath
Thickness

Approx.
Overall
Diameter

Approx.
Cable
Weight

n x mm2

mm

mm

mm

kg/km

3x35
3x50
3x70
3x95
3x120
3x150
3x185
3x240
3x300

8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0

3.0
3.1
3.2
3.3
3.5
3.6
3.7
3.8
4.0

68.4
69.9
75.1
77.9
82.5
85.3
89.4
95.1
100.2

4620
5206
6175
7251
8252
9360
10663
12781
15046

2. Electrical Data
Cross section Area

mm2
2

mm

Screen Area
DC Resist at 20oC
o

Ac Resist at 90 C

35
16

W
/ km 0.524
W
/ km 0.668

70

95

120

150

185

240

300

16

16

16

16

25

25

25

25

0.387

0.268

0.193

0.153

0.124

0.0991

0.0754

0.0601

0.494

0.342

0.247

0.196

0.159

0.1286

0.0993

0.0806

50

Inductance

mh/ km

0.470

0.441

0.423

0.404

0.389

0.376

0.364

0.348

0.338

Capacitance

m
F/ km 0.133

0.143

0.159

0.174

0.188

0.201

0.216

0.238

0.256

Charging current

A/ km

0.903

0.974

1.081

1.181

1.274

1.366

1.464

1.616

1.737

Dielectic losses

W/m

0.130

0.140

0.156

0.170

0.183

0.197

0.211

0.233

0.250

Cable in ground

Cable in free air

177
200

205
240

252
290

302
360

340
405

380
455

429
520

494
610

555
690

5.0
2.29

7.15
2.29

10.0
2.29

13.5
2.29

17.1
2.29

21.4
3.58

26.4
3.58

34.4
3.58

42.9
3.58

Current Ampacity

Short circuit current


Conductor S.C (1 Sec)

KA

Screen S.C (1 Sec)

KA

Medium Voltage Cables

31

Three Core Cable

For Installations outdoor in ground, in ducts and indoor on trays.


Type
Standard
Conductor
Conductor Screen
Insulation
Insulation Screen
Metallic Screen
Bedding
Armoring
Jacketing

CU/XLPE/ STA/PVC, 18/30 KV


IEC 60502-2
Circular stranded Compacted copper (or Aluminum)
Bonded semiconducting material
XLPE material
Strippable semiconducting material (or Bonded)
Copper tape (or Copper Wire)
PVC compound (or LSHF or PE)
Galvanized steel tapes
PVC compound (or LSHF or PE)

:
:
:
:
:
:
:
:
:
:

TECHNICAL INFORMATION
1. Weight and Dimension Data
Nominal
Cross
Section

Nominal
Insulation
Thickness

Steel
Tape
Thickness

Nominal
Sheath
Thickness

Approx.
Overall
Diameter

Approx.
Cable
Weight

n x mm2

mm

mm

mm

mm

kg/ km

3x35
3x50
3x70
3x95
3x120
3x150
3x185
3x240
3x300

8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0

0.5
0.5
0.5
0.5
0.8
0.8
0.8
0.8
0.8

3.1
3.2
3.3
3.4
3.6
3.7
3.8
4.0
4.1

71.0
73.7
77.9
80.6
85.5
89.8
92.6
98.5
103.3

5786
6403
7456
8595
10419
11625
13019
15343
17692

2. Electrical Data
Cross section Area

mm2
2

mm

Screen Area
DC Resist at 20oC

35
16

0.524
W
/ km

70

95

120

150

185

240

300

16

16

16

16

25

25

25

25

0.387

0.268

0.193

0.153

0.124

0.0991

0.0754

0.0601

0.196

0.159

0.1286

0.0993

0.0806

50

Ac Resist at 90 C

0.668
W
/ km

0.494

0.342

0.247

Inductance

mh/ km

0.470

0.449

0.423

0.404

0.389

0.376

0.364

0.348

0.338

Capacitance

m
F/ km 0.133

0.143

0.159

0.174

0.188

0.201

0.216

0.238

0.256

Charging current

A/ km

0.903

0.974

1.081

1.181

1.274

1.366

1.464

1.616

1.737

Dielectic losses

W/m

0.130

0.140

0.156

0.170

0.183

0.197

0.211

0.233

0.250

Cable in ground

Cable in free air

174
199

204
235

245
287

295
350

335
400

370
450

420
505

483
590

540
655

5.0
2.29

7.15
2.29

10.0
2.29

13.5
2.29

17.1
2.29

21.4
3.58

26.4
3.58

34.4
3.58

42.9
3.58

Current Ampacity

Short circuit current

32

Conductor S.C (1 Sec)

KA

Screen S.C (1 Sec)

KA

Medium Voltage Cables

Three Core Cable

For Installations outdoor in ground, in ducts and indoor on trays.


Type
Standard
Conductor
Conductor Screen
Insulation
Insulation Screen
Metallic Screen
Bedding
Armoring
Jacketing

:
:
:
:
:
:
:
:
:
:

CU/XLPE/SWA/PVC, 18/30 KV
IEC 60502-2
Circular stranded Compacted copper (or Aluminum)
Bonded semiconducting material
XLPE material
Strippable semiconducting material (or Bonded)
Copper tape (or Copper Wire)
PVC compound (or LSHF or PE)
Galvanized Steel Wires
PVC compound (or LSHF or PE)

TECHNICAL INFORMATION
1. Weight and Dimension Data
Nominal
Cross
Section

Nominal
Insulation
Thickness

Steel
Wire
Diameter

Nominal
Sheath
Thickness

Approx.
Overall
Diameter

Approx.
Cable
Weight

n x mm2

mm

mm

mm

mm

kg/ km

3x35
3x50
3x70
3x95
3x120
3x150
3x185
3x240
3x300

8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0

2.50
3.15
3.15
3.15
3.15
3.15
3.15
3.15
3.15

3.2
3.4
3.5
3.6
3.7
3.8
3.9
4.1
4.2

73.5
78.2
82.4
85.9
90.2
93.3
97.2
102.0
107.1

7862
9721
10909
12283
13390
14719
16238
18792
21303

2. Electrical Data
Cross section Area

mm2

35

50

70

16

16

16

16

16

25

25

25

25

0.153

0.124

0.0991

0.0754

0.0601

mm

Screen Area

95

120

150

185

240

300

DC Resist at 20 C

0.524
W
/ km

0.387

0.268

0.193

Ac Resist at 90o

0.668
W
/ km

0.494

0.342

0.247

0.196

0.159

0.1286

0.0993

0.0806

Inductance

mh/ km

0.470

0.449

0.423

0.404

0.389

0.376

0.364

0.348

0.338

Capacitance

m
F/ km 0.133

0.143

0.159

0.174

0.188

0.201

0.216

0.238

0.256

Charging current

A/ km

0.903

0.974

1.081

1.181

1.274

1.366

1.464

1.616

1.737

Dielectic losses

W/m

0.130

0.140

0.156

0.170

0.183

0.197

0.211

0.233

0.250

Cable in ground

Cable in free air

174
200

204
235

245
290

295
350

330
400

370
488

420
500

470
585

520
655

5.0
2.29

7.15
2.29

10.0
2.29

13.5
2.29

17.1
2.29

21.4
3.58

26.4
3.58

34.4
3.58

42.9
3.58

Current Ampacity

Short circuit current


Conductor S.C (1 Sec)

KA

Screen S.C (1 Sec)

KA

Medium Voltage Cables

33

General Characteristics

Medium Voltage Electric Cable - 6,6kV to 33kV to SANS 1339


Mechanical and electrical properties
of XLPE measured on the cable
Tensile strength at 20 OC
MPa (N/mm2)
Elongation at break at 20 OC (%)
Volume resistivity at 20 OC - 90 OC Ohm/cm
Dielectric power factor at 20 OC
Dielectric power factor at 95 OC

Result

Requirement

Mean 15

12,5

Mean 350
1016
10.10-4
20.10-4

200
1014
30.10-4
60.10-4

The performance of the cable at low temperatures is determined by the properties of the sheath material, the cold flexibility
of which is adequate down to - 15 OC. This does not apply to temperatures during installation of the cables.
Working temperatures
O
Conductor temperature for continuous operation 90 C.
O
Conductor temperature during emergency loads of 130 C (up to 33kV).
Maximum duration of 8 hours continuously, with a maximum total of 125 hours/annum.
O
Conductor temperature after short-circuit 250 C.
O
Screen and armouring temperature after short-circuit 200 C (PVC sheath assumed).
Bending radii

Single-core

3-core

Recommended
Minium
At sealing ends

17 x D
15 x D
12 x D

15 x D
12 x D
10 x D

D = Overall
cable diameter
(mm)

Current rating
Explanation of the tables.
Conditions, under which the values mentioned in the tables apply, are :
One three-phase circuit, continuously fully loaded.
Single-core cables in trefoil formation touching and in flat formation respectively with axial separation of 150 mm and
regular transposition.
Conductor temperature 90 C
Ground temperature 25 OC.
Depth of laying 800 mm
Soil thermal resistivity 1.2 K.m/W.
Ambient temperature 30C in free air (Shaded)
Solidly bonded at both ends.
Absence of Other heat sources.
Remarks
In certain types of soil, a conductor operating temperature of 90 OC for cables laid direct or in pipes may result in drying of
the soil where a critical temperature of 55 C is exceeded. Various alternatives have been recommended, eg:
a) Restricting the sheath temperatures to 55 C (by reducing conductor temperature);
b) Rating the cable for fully dried out soil (thermal resistivity 3 K.m./W) (both methods a & b causes substaintial reductions
in current ratings);
c) Using a back-fill of stable thermal resistivity not exceeding 1.5 K.m/W and rated accordingly for a conductor temperature
of 90 C.
d) Using the CIGRE method (Electra No.104, January 1986, Pages 11-22) of calculating a revised current rating assuming
a partially dried out soil model.
Tirupati Plastomatics Power Cables Technical Division will be plased to advise on ratings and backfills necessary for your
requirements.
Tirupati Plastomatics Cables Technical Division will be pleased to advise on ratings on ratings and backfills necessary for
your requirements.
Note :
The nominal data supplied in this publication has been compiled with every attempt at accuracy with the sole purpose of
providing for the reader a convenient and practical directive without commitment.
All dimensions are in line with SANS 1339, unless otherwise stated.
34

Medium Voltage Cables

Manufacturing Range

Medium Voltage Electric Cable - 6,6kV to 33kV to SANS 1339

Type

Specification

Tirupati
Type A

XLPE insulated, individually


copper tape screened,
PVC bedded, steel wire
armoured, PVC sheathed

Tirupati
Type A

XLPE insulated, copper tape


screened, PVC bedded,
aluminium wire armoured,
PVC sheathed

No. of
Cores

Voltage (kV)
3,8/6,6 - 6,35/11
8,7/15 - 12,7/22
19/33
3,8/6,6 - 12,7/22

19/33
3,8/6,6 - 6,35/11

Tirupati
Type B

XLPE insulated, individually


copper tapes screened,
unarmoured, PVC sheathed

Tirupati
Type B

XLPE insulated, copper (single)


taped screened,
unarmoured, PVC sheathed

Tirupati
special
type

XLPE insulated, individually


copper tape screened,
equalising cu tape, with or
without steel wire armour,
PVC sheathed

8,7/15 - 12,7/22
19/33
3,8/6,6 - 12,7/22

19/33
3,8/6,6 - 6,35/11

8,7/15 - 12,7/22
19/33

Conductor
Sizes (mm2)
cu: 25-400
alu: 50-400
cu: 25-240
alu: 50-240
cu: 50-240
alu: 50-240
cu: 25-630
alu: 50-630
cu: 50-500
alu: 50-500
cu: 25-400
alu: 50-400
cu: 25-240
alu: 50-240
cu: 25-240
alu: 50-240
cu: 25-630
alu: 50-630
cu: 50-500
alu: 50-500
cu: 25-400
alu: 50-400
cu: 25-240
alu: 50-240
cu: 50-240

Standard drum lengths :


300 metres - longer lengths can be manufactured if required.

* Note : The maximum and minimum conductor size above are our standard.
Please enquire if smaller or larger than the standard size is required.
Cables and dimensions are in accordance with SANS 1339, except for the 87/15kV cables.
No data is given in this brochure for cables above 33kV.

Medium Voltage Cables

35

Type of Cables

Medium Voltage Electric Cable - 6,6kV to 33kV


Tirupati Plastomatics TYPE A
Cables are designed to carry high earth fault currents
comparable with system symmetrical fault currents.
3 Core Type A cables are supplied with galvanised steel wire
armouring.
Single-core cables are normally supplied arm oured with a
single layer of aluminium wires.

TIRUPATI TYPE A

TIRUPATI TYPE A

TIRUPATI TYPE A
CROSS SECTION
(Three Core)

TIRUPATI TYPE A
CROSS SECTION
(Single Core)

TIRUPATI PLASTOMATICS TYPE B


Cables are designed to carry limited earth fault currents of
1000 A for one second.
Higher currents may be carried where the total earth fault
clearance time is less than one second, provided that the
product of the square of the current in amperes and the
clearance time in seconds does not exceed 105.

TIRUPATI TYPE B

36

TIRUPATI TYPE B

Medium Voltage Cables

TIRUPATI TYPE B
CROSS SECTION
(Three Core)

TIRUPATI TYPE B
CROSS SECTION
(Single Core)

Construction

Medium voltage Electric Cable - 6,6kV to 33kV

Construction of the cables


1

Conductor - aluminium or copper

2
3
4
5
6
7
8
9
10
11

Conductor screen - extruded semi conductive layer integral with:


Insulation - XLPE
Core screen - extruded free strippable semi-conductive layer
Semi-conductive numbered tape * *
Metalic earth screen - copper tape (s)
Fillers - pre-formed plastic material *
Binder tape
Inner sheath (bedding)
Armouring (Steel wire or Aluminium wire)
Outer sheath

* Other materials may be used when required.


** Core identification : alternative printed numbers on each core - 1,2 and 3 or Colour Strips.

Medium Voltage Cables

37

Properties and applications


Medium voltage Electric Cable - 6,6kV to 33kV

Due to the fact that Tirupati Plastomatics XLPE insulation is resistant to high temperatures, it is also obvious that
higher temperatures are permissible in the cable.
For XLPE, continuous conductor temperatures up to 90 OC are permissible, whilst for some hours a temperature
of 130 C is permissible. In case of short-circuit the conductor can withstand considerably higher temperature
(up to 250 OC).

This important specific characteristic, n contrast with those generally applicable to plastics, give XLPE insulated
cables the following advantages:
suitable for a sustained conductor temperature of 90 C as a result of which a high current carrying capacity
is obtained.
suitable up to 125 hours/annum, (no event being longer than 8 hours continuously) at conductor temperature of
130 C so that emergency loads can be tolerated
no drainage problems
clean handling
relatively low cost per installed kVA

In addition to the normal application as underground cables, the following specific possibilities can be indicated:

installation in buildings (vertical mounting)


installation in outes with great difference in height
installation in substations and power stations
This high current-carrying capacity can profitably be used in those cases where higher temperatures do not
occur for to long or too often, viz. as a result of daily or yearly winter peaks. Normally improved thermal
dissipation during the night or colder weather improves the thermal stability of the installation.

Notwithstanding these claims for higher sustained current ratings, where higher than normal ambient
temperatures are obtained, (as in enclosed cable ducts or in ground which may dry out progressively under a
sustained buried cable load) care should be taken when selecting the conductor material and area. Refer to
remarks (a) and (b) under General Characteristics.

In the current rating tables, the values in brackets next to the continuous current values, indicates the outer
sheath temperature in OC, expected when the cable is fully loaded under the stated conditions of installation.

38

Medium Voltage Cables

Medium Voltage Cables

39

60.0
64.0
68.5
72.5
78.5
85.0

53.1

56.2

60.0

65.9

72.0

82.0

69.2

49.8

74.5

62.2

55.5

68.0

56.0

45.8

62.5

52.1

52.0

59.3

49.0

49.5

55.5

45.7

42.3

51.5

41.8

39.6

48.0

38.2

47.0

44.0

35.6

37.4

41.5

33.3

17865

14955

12775

11240

9370

8170

6995

5895

5215

4655

17320

14240

12080

9900

6850

7590

6395

5320

4230

3730

12070

10580

9240

8350

7045

6340

5635

5015

11470

9870

8510

6995

6345

5755

5045

4430

TIRUPATI Type A - Three Core

40

Medium Voltage Cables

4.5

4.5

4.5

4.5

4.5

4.5

4.5

4.5

7.0

8.2

9.8

11.5

13.0

14.4

16.1

18.7

5.9

7.0

8.2

9.8

11.5

13.0

14.4

16.1

18.7

8.2

9.8

11.5

13.0

14.4

16.1

18.7

35

50

70

95

120

150

185

240

25

35

50

70

95

120

150

185

240

50

70

95

120

150

185

240

8.0

8.0

8.0

8.0

8.0

8.0

8.0

5.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

4.5

5.9

25

86.6

80.6

76.7

73.6

70.3

66.4

62.8

75.2

69.4

66.5

62.2

59.2

55.2

51.5

49.0

46.7

70.9

64.1

61.2

57.9

54.9

50.9

47.1

44.5

42.2

3.55

3.55

3.55

3.55

3.55

3.15

3.15

3.55

3.15

3.15

3.15

3.15

2.50

2.50

2.50

2.50

3.55

3.15

3.15

3.15

3.15

2.50

2.50

2.50

2.50

103.3

97.1

92.8

89.8

86.3

79.0

76.0

91.5

83.0

78.3

75.8

72.0

67.2

62.0

59.3

57.5

87.0

78.0

74.0

70.0

67.5

61.5

57.5

55.3

52.5

20 060

17 620

15 945

14 655

13 280

11 280

9 980

17 545

14 645

13 005

11 650

10 445

9 155

7 250

6 600

6 060

16 760

13 800

12 180

10 835

9 725

7 830

6 630

5 915

5 380

15 700

14 060

13 020

12 275

11 375

9 910

9 145

13 150

11 060

10 115

9 340

8 625

7 815

6 390

12 350

10 195

9 295

8 530

7 865

6 465

5 745

0.164

0.206

0.253

0.320

0.443

0.641

0.128

0.159

0.196

0.247

0.342

0.494

0.668

0.927

0.098

0.128

0.159

0.196

0.247

0.342

0.494

0.211

0.265

0.325

0.410

0.568

0.822

0.161

0.211

0.265

0.325

0.410

0.568

0.822

0.075

0.099

0.124

0.153

0.193

0.268

0.387

0.098

0.494
0.342
0.247
0.196
0.159
0.128
0.098

0.125

0.641
0.443
0.320
0.253
0.206
0.164
0.125

0.097
0.139
0.131
0.123
0.119
0.115
0.111
0.106

0.822
0.568
0.410
0.325
0.265
0.211
0.161

0.101

0.104

0.108

0.112

0.119

0.126

0.132

0.140

0.093

0.097

0.100

0.103

0.107

0.108

0.113

0.126

0.133

0.161

*Rated Voltage 19/33kV

0.075

0.099

0.124

0.153

0.193

0.268

0.387

0.524

0.727

0.125

0.164

0.206

0.253

0.320

0.443

0.641

0.668

*Rated Voltage 12.7/22 KV

0.075

0.099

0.124

0.153

0.193

0.268

0.387

0.524

0.927

*Rated Voltage 8.7/15kV


0.727

220

199

185

173

162

147

133

293

263

243

227

210

189

170

156

143

345

308

284

264

244

219

195

179

164

460

410

360

325

290

245

200

470

410

360

325

290

245

200

170

145

470

410

360

325

290

240

200

170

140

370

320

285

255

225

190

155

370

320

285

255

225

190

155

370

320

285

255

225

190

155

370

325

290

260

230

195

160

370

325

290

260

230

195

160

135

115

370

325

290

260

230

195

160

135

115

230
280
340
385
435
500
580

150
180
205
230
255
295

190

160

580

490

440

385

335

280

225

190

125

295

255

230

205

180

150

125

155

470

400

350

310

270

220

180

460

395

340

305

265

220

180

460

390

340

300

260

220

175

Medium Voltage Cables

41

6775
1035
1175
1345
1675
1980
2285
2765
3200
3755
4545
5595
6820

25.5

27.0

28.5

30.5

32.0

33.0

38.0

41.5

45.0

49.5

24.5

26.0

27.0

29.5

30.5

32.4

35.5

37.0

39.5

42.2

46.0

50.0

18.7

20.3

22.1

23.5

24.9

26.7

29.5

32.6

36.5

39.3

18.1

19.4

20.5

22.4

23.9

25.3

26.7

28.5

31.1

33.8

37.3

39.7

5480

4430

3605

3025

2500

2150

1855

1535

1240

1075

24.0

17.6

943

23.5

16.5

3795

3185

2640

2320

2015

1815

1530

1375

1215

1060

3735

3085

2535

2175

1885

1555

1390

1255

1090

955

TIRUPATI Type A - Single Core

42

Medium Voltage Cables

20.8

21.9

23.0

24.6

26.4

27.8

29.0

30.7

33.3

36.3

40.0

40.8

22.8

23.9

25.0

26.6

28.4

29.8

31.2

33.0

35.3

38.5

42.0

43.0

30.0

31.6

33.4

34.8

36.4

38.2

40.8

43.7

47.2

49.6

4.5

4.5

4.5

4.5

4.5

4.5

4.5

4.5

4.5

4.5

4.5

4.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

8.0

8.0

8.0

8.0

8.0

8.0

8.0

8.0

8.0

8.0

2.5

2.5

2.5

2.5

2.5

2.5

2.0

2.0

2.0

2.0

2.5

2.5

2.5

2.0

2.0

2.0

2.0

2.0

2.0

1.6

1.6

1.6

2.5

2.5

2.0

2.0

2.0

2.0

2.0

2.0

1.6

1.6

1.6

1.6

60.3

57.7

54.1

50.9

48.3

46.4

43.6

42.2

40.3

38.6

53.3

52.1

48.5

44.1

41.6

39.9

38.0

36.8

34.9

32.1

31.0

29.9

51.1

50.1

45.1

42.1

39.3

37.4

36.2

34.6

31.6

29.9

28.8

27.7

0.268
0.193
0.153
0.124
0.099
0.075
0.060
0.047
0.037

1360
1655
1825
1990
2200
2535
2805
3610
3980

0.193
0.153
0.124
0.099
0.075
0.060
0.047
0.037

1 830
1 985
2 175
2 370
2 715
3 240
3 895
4 240

7 245

1 900
2 070
2 290
2 455
2 825
3 080
3 410
3 860
4 450
4 970

2 185
2 515
2 895
3 215
3 805
4 255
4 890
5 775
6 845
7 995

6 195

5 175

4 135

3 550

3 120

2 765

0.037

0.047

0.060

0.075

0.099

0.124

0.153

0.193

0.268

0.387

0.268

1 640

2 430

2 085

1 670
0.387

0.524

0.727

0.387

1215

0.524

0.727

1 365

1 480

1 340

7 005

6 005

4 765

3 965

3 370

2 935

2 580

2 255

1 810

1 505

1 335

1 190

0.247
0.196
0.159
0.128
0.098
0.079
0.063
0.051

0.320
0.253
0.206
0.164
0.125
1.100
1.078
0.061

0.061

0.078

0.100

0.125

0.164

0.206

0.253

0.320

0.443

0.051

0.063

0.79

0.98

0.128

0.159

0.196

0.247

0.342

0.494

0.342

0.443

0.641

0.494

0.668

0.927

0.051

0.063

0.079

0.098

0.128

0.159

0.196

0.247

0.342

0.494

0.641

0.061

0.078

0.100

0.125

0.164

0.206

0.253

0.320

0.443

0.641

0.668

0.927

0.094

0.096

0.099

0.102

0.107

0.111

0.114

0.118

0.125

0.133

0.200

0.205

0.211

0.219

0.227

0.234

0.240

0.246

0.257

0.268

0.277

0.287

454

423

383

345

308

284

264

244

219

195

179

164

650(80)

580(80)

510(79)

460(78)

410(75)

360(75)

325(74)

290(74)

245(73)

200(72)

170(72)

140(71)

0.111
0.106
0.102
0.099
0.097

0.211
0.161
0.130
0.102
0.080

0.201

0.205

0.212

0.220

0.228

0.234

0.240

0.247

0.258

0.268

0.278

0.287

383

358

325

293

263

243

227

210

189

17

156

143

0.080

0.102

0.130

0.161

0.211

0.265

0.325

0.410

0.568

0.822

0.104

0.107

0.111

0.115

0.120

0.124

0.128

0.133

0.141

0.149

0.202

0.207

0.214

0.222

0.230

0.236

0.242

0.249

0.259

0.270

290(67)
350(68)
405(69)
460(69)
520(69)
590(70)
690(70)
800(70)
920(71)

175(78)
205(79)
230(79)
255(80)
280(80)
315(81)
350(82)
385(83)
430(83)

220(61)

480(66) 385(64)

750(69) 630(68)
825(70) 705(69)
600(79) 520(84) 600(79) 525(78) 520(84) 430(83) 480(84) 430(83) 920(70) 730(70)

665(69) 550(68)

610(68) 510(65)
550(78) 470(84) 550(78) 480(77) 470(84) 380(81) 440(84) 380(81) 800(70) 640(70)

510(78) 410(84) 510(77) 430(76) 410(84) 330(78) 410(83) 330(78) 685(70) 540(70)

460(77) 370(77) 470(76) 395(75) 370(83) 295(77) 375(83) 295(77) 610(69) 490(68)

540(67) 440(65)

430(64) 345(63)
365(76) 285(76) 390(74) 315(73) 290(82) 230(77) 310(82) 230(77) 460(69) 360(67)
410(77) 320(76) 425(75) 350(74) 325(83) 260(77) 340(83) 260(77) 520(69) 410(68)

385(63) 305(63)
325(75) 255(74) 355(72) 285(71) 260(82) 205(76) 285(82) 205(76) 410(68) 320(67)

220(60)

185(50)

884(70) 715(69)

750(70) 640(68)

650(70) 560(68)

590(68) 500(67)

525(67) 435(66)

475(66) 385(65)

430(65) 345(65)

385(64) 305(63)

320(63) 255(62)

265(62) 205(62)

320(62) 255(62)

740(70)

640(70)

550(70)

480(70)

420(69)

360(69)

315(69)

275(67)

225(67)

185(67)

290(74) 225(74) 320(72) 220(70) 235(81) 180(75) 255(81) 180(75) 355(67) 280(67)

210(64)

165(62)

235(67)

135(77)

185(60)

245(73) 190(74) 270(70) 215(70) 195(81) 150(75 220(81) 155(75) 295(66) 230(66)

155(79)

130(78)

490(83)

445(82)

390(82)

380(82)

340(80)

315(80)

285(80)

260(79)

220(78)

180(76)

200(67)

160(65)

260(60) 205(62)

430(83)

380(82)

330(82)

295(81)

255(80)

230(80)

205(81)

180(80)

150(79)

125(78)

155(76)

130(74)

200(72) 155(72) 230(68) 180(68) 160(81) 125(74) 180(80) 125(74) 235(65) 185(65)

115(79)
140(80)

520(84)

470(83)

410(83)

370(81)

325(80)

290(80)

260(80)

230(80)

195(79)

160(77)

195(67)

530(79)

480(78)

440(77)

395(75)

350(82)

315(74)

285(73)

255(72)

215(70)

170(68)

165(65)

600(80)

555(80)

490(79)

470(77)

430(76)

390(74)

355(73)

320(72)

275(70)

230(69)

140(77)

115(76)

170(71)

535(80)

480(79)

420(78)

370(77)

320(76)

285(75)

255(75)

225(74)

190(74)

155(73)

195(67)

165(66)

145(70)

330(59) 250(60)
380(60) 300(60)
430(62) 345(60)
480(63) 385(61)
540(64) 440(63)
610(66) 500(63)
670(66) 560(65)
750(67) 640(66)
830(69) 720(67)

25(71) 235(79) 185(78) 255(80) 205(79) 360(64) 280(63)


325(73) 255(73) 350(72) 290(72) 260(80) 205(79) 280(80) 225(79) 410(65) 320(63)
365(74) 285(74) 385(74) 315(73) 290(80) 230(80) 310(81) 245(80) 470(65) 365(64)
410(75) 320(75) 420(75) 345(74) 325(81) 260(80) 335(81) 280(80) 530(65) 415(65)
460(76) 370(76) 470(77) 390(76) 370(81) 295(80) 370(81) 310(81) 610(67) 490(66)
505(77) 410(77) 495(78) 430(77) 410(81) 330(82) 400(82) 340(83) 690(67) 555(67)
266 5758(78) 470(78) 545(78) 480(77) 460(82) 380(82) 440(83) 380(84) 800(68) 650(67)
650(79) 540(79) 590(79) 520(78) 520(83) 470(84) 480(84) 420(84) 920(68) 745(68)
283

243

220

199

185

173

162

290(73) 230(73) 315(71)

260(58) 205(58)
245(72) 190(72) 270(68) 215(68) 195(79) 155(75) 215(78) 170(77) 300(63) 235(63)
147

133

200(71) 155(71) 225(68) 175(66) 160(77) 125(78) 180(76) 140(78) 240(62) 190(62)

Rated Voltage 19/33kv

0.115

0.119

0.122

0.130

0.138

0.265

0.325

0.410

0.568

0.822

0.145

0.153

Rated Voltage 12.7/22kv

0.080

0.102

0.130

0.161

0.211

0.265

0.325

0.410

0.568

0.822

0.140

0.147

Rated Voltage 8.7/15kv

Medium Voltage Cables

43

2265
2675
3160
4060
4770
5665
6695
7925
9605
12060
4545
2965
3475
4385
5140
6055
7090
8360
9990
12380

35.0

37.5

40.5

44.0

47.5

51.0

54.0

58.5

64.5

71.5

39.5

41.5

44.5

48.0

52.0

55.0

58.5

62.5

68.0

74.5
6470

5575

4745

4155

3685

3305

3005

2560

6175

5165

4280

3750

3295

2895

2655

2235

TIRUPATI Type B - Three Core

44

Medium Voltage Cables


2770
3185
3705
4635
5585
6505
7565
8835
10575
3200
3615
4165
5095
6085
7045
8155
9455
11215
5310
6305
7345
8380
9510
10885
12710

44.0

46.5

49.0

53.0

57.0

60.5

63.5

67.5

73.5

49.0

51.5

54.0

57.5

62.0

65.0

68.5

72.5

78.5

65.5

65.5

74.0

77.0

80.0

84.0

90.5

4.5

4.5

4.5

4.5

4.5

4.5

4.5

4.5

4.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

5.5

8.0

8.0

8.0

8.0

8.0

8.0

8.0

0.107
0.103
0.100
0.097
0.093

3720
4150
4750
5195
6115

8250

7235

6555

6005

6460

4875

173
185
199
220

0.119
0.115
0.111
0.106

293

162

0.097

6765

263

0.123

0.101

5785

243

227

147

0.104

5230

133

0.108

4695

210

0.131

0.112

4195

189

170

156

143

345

308

284

264

244

219

195

179

164

0.139

0.119

6695

4360

0.126

0.132
3230

Rated Voltage 19/33 kV

0.113

0.140

0.120

3215

0.126

0.133
2780

Rated Voltage 12.7/22 kV

Rated Voltage 8.7/15 kV

610

520

455

400

350

290

230

480

405

355

310

270

225

180

470

400

350

310

265

220

180

Fault rating - kA for 1 sec (Copper)


Medium voltage Electric Cable - 6,6kV to 33kV

Earth Fault

* Applicable to PVC sheathed cable


Symmetrical Faults
Maximum permissible short-circuit current rating for Tirupati Plastomatics XLPE cables up to 33kV Copper
conductors

Medium Voltage Cables

45

Fault rating - kA for 1 sec (Aluminium)


Medium voltage Electric Cable - 6,6kV to 33kV
Earth Fault
TYPE A - 3-Core
25
35
50
70
95
120
150
185
240
300

7,4
11,1
12,0
12,9
17,3
18,3
19,4
20,8
25,5
27,2

10,4
12,2
13,1
17,6
18,7
19,7
20,8
25,0
26,8
28,6

16,5
17,2
19,7
20,8
25,0
25,9
27,2
28,6
30,3
32,1

21,3
28,1
29,4
30,3
31,6
33,0
34,7

Symmetrical Faults
Maximum permissible short-circuit current rating for Tirupati Plastomatics XLPE cables up to 33kV Aluminium
conductors

92

46

Medium Voltage Cables

Rating Factors

Medium voltage Electric Cable - 6,6kV to 33kV


Tirupati cable in ground

Tirupati cable in ground

Medium Voltage Cables

47

Rating Factors

Medium voltage Electric Cable - 6,6kV to 33kV

Tirupati Plastomatics XLPE cable on trays, ladders or building structures

1
2

0.97
0.97

0.85
0.83

0.74
0.71

1
2

0.97
0.97

0.96
0.94

0.93
0.90

touching

1
2

1.00
1.00

0.86
0.82

0.74
0.71

with spacing

1
2

1.00
1.00

1.00
1.00

1.00
1.00

0.94

0.80

0.86

0.94

0.90

0.87

0.94

0.80

0.86

0.94

0.90

0.87

0.89

0.76

0.57

0.89

0.81

0.77

Type of laying

On
metal
tray

On
metal
ladder

On
floor

Number of cables

No. of
ladders
or trays

touching
with spacing

touching
with spacing

30 mm

30 mm

d max 30 mm

30 mm

30 mm

d max 30 mm

Rating factors

30 mm

touching
On
floor

30 mm

with spacing
d max 30 mm

In
ceiling

48

touching
with spacing

Medium Voltage Cables

30 mm

d max 30 mm

30 mm

High Voltage Cables to IS : 7098 (Part - 2)


TABLE 1 - 3.8/6.6 KV HT XLPE SINGLE CORE ALUMINIUM CONDUCTOR CABLES
TIRUPATI PLASTOMATICS" SINGLE CORE ALUMINIUM CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES
CONFORMING TO IS: 7098 PART-2/1985:
UNARMOURED CABLE
Nominal Nominal Approx. Approx.
Thickness Thickness Overall Weight
of XLPE of PVC Diameter
of
Insulation Outer
of
Cable
Sheath
Cable
mm
mm Kg/Km
Sq.mm. mm
Nominal
Size
of
Conductor

35
50
70
95
120
150
185
240
300
400
500
630
800
1000

2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
3.0
3.3
3.5
3.5
3.5
3.6

2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.2
2.2
2.2
2.4
2.4
2.6
2.8

20.3
21.4
23.2
24.7
26.2
27.3
29.0
32.2
34.7
38.7
42.2
45.8
50.5
55.3

453
502
604
753
846
952
1103
1347
1548
1953
2405
2855
3453
4247

ALUMINIUM STRIP ARMOURED CABLE ALUMINIUM ROUND WIRE ARMOURED CABLE CURRENT CARRYING CAPACITY
Minimum
Minimum Approx. Approx. Nominal Minimum Approx. Approx.
In
In
In
Thickness Nominal Thickness Overall Weight Dimension Thickness Overall Weight of Ground at Duct at
Air
at
of Inner Dimension of PVC Diameter
of
of
of
PVC
Diameter
Cable.
30
C.
30
C.
40
C.
of
Sheath
Outer
of
Cable
Round
Outer
of
Strip
Sheath
Cable
Wire
Sheath
Cable
mm
mm
mm
mm Kg/Km mm
mm
mm Kg/Km Amps. Amps. Amps.
0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.40
0.40
0.40
0.50
0.50
0.50
0.60

4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8

1.40
1.40
1.40
1.40
1.40
1.40
1.56
1.56
1.56
1.56
1.72
1.88
1.88
2.04

21.3
22.2
24.2
25.4
27.3
28.8
31.3
32.8
36.4
40.4
43.8
47.9
51.3
56.8

553
605
752
847
947
1105
1253
1503
1755
2204
2652
3204
3752
4604

1.6
1.6
1.6
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.0
2.0
2.5
2.5

1.40
1.40
1.40
1.40
1.40
1.56
1.56
1.56
1.56
1.72
1.88
1.88
2.04
2.20

22.8
23.1
25.9
26.8
29.3
30.8
32.9
35.9
38.4
42.9
46.8
49.8
55.3
60.8

624
705
803
954
1055
1203
1402
1704
2005
2455
2954
3453
4304
5155

120
140
175
205
235
260
295
340
385
440
495
560
620
680

105
125
155
180
205
230
260
300
335
380
430
480
530
580

145
170
215
260
305
345
395
470
540
630
730
840
960
1070

*Normal
Delivery
Length.
Mtrs.
500
500
500
500
500
500
500
500
500
500
500
500
500
500

TABLE 2 - 3.8/6.6 KV (E) HT XLPE SINGLE CORE COPPER CONDUCTOR CABLES


TIRUPATI PLASTOMATICS" SINGLE CORE COPPER CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES
CONFORMING TO IS: 7098 PART-2/1985:
UNARMOURED CABLE
Nominal Nominal Approx. Approx.
Thickness Thickness Overall Weight
of XLPE of PVC Diameter
of
Insulation Outer
of
Cable
Sheath
Cable
mm
mm Kg/Km
Sq.mm. mm
Nominal
Size
of
Conductor

35
50
70
95
120
150
185
240
300
400
500
630
800
1000

2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
3.0
3.3
3.5
3.5
3.5
3.6

2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.2
2.2
2.2
2.4
2.4
2.6
2.8

20.5
21.3
23.4
24.2
25.8
27.4
29.4
32.3
34.8
38.8
42.3
45.8
50.2
54.8

675
853
1055
1304
1603
1905
2252
2853
3454
4455
5503
6754
8455
10452

ALUMINIUM STRIP ARMOURED CABLE ALUMINIUM ROUND WIRE ARMOURED CABLE CURRENT CARRYING CAPACITY
Minimum
Minimum Approx. Approx. Nominal Minimum Approx. Approx.
In
In
In
Thickness Nominal Thickness Overall Weight Dimension Thickness Overall Weight of Ground at Duct at
Air
at
of Inner Dimension of PVC Diameter
of
of
of PVC Diameter Cable.
30
C.
30
C.
40
C.
of
Sheath
Outer
of
Cable
Round
Outer
of
Strip
Sheath
Cable
Wire
Sheath
Cable
mm
mm
mm
mm Kg/Km mm
mm
mm Kg/Km Amps. Amps. Amps.
0.30
0.30
0.30
0.30
0.30
0.30
0.30
0.40
0.40
0.40
0.50
0.50
0.50
0.60

4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8

1.40
1.40
1.40
1.40
1.40
1.40
1.56
1.56
1.56
1.56
1.72
1.88
1.88
2.04

21.3
22.4
24.5
25.8
27.3
28.8
31.4
32.8
35.8
40.4
43.3
47.8
51.4
56.8

755
904
1153
1452
1701
2055
2403
3005
3604
4653
5755
7102
8703
10805

1.6
1.6
1.6
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.0
2.0
2.5
2.5

1.40
1.40
1.40
1.40
1.40
1.56
1.56
1.56
1.56
1.72
1.88
1.88
2.04
2.20

22.8
23.7
25.6
27.2
29.3
30.8
32.8
35.6
37.3
42.8
46.7
50.3
55.4
60.8

854
1005
1254
1553
1805
2152
2553
3204
3853
4954
6055
7353
9252
11355

155
185
225
265
300
335
380
435
490
550
610
680
740
790

140
160
195
235
265
295
330
380
425
480
530
580
630
670

185
220
275
340
390
440
510
600
680
790
910
1030
1140
1250

*Normal
Delivery
Length.
Mtrs.
500
500
500
500
500
500
500
500
500
500
500
500
500
500

The above data is approximate and subject to manufacturing tolerance.


* Delivery Length tolerance is
5% Length more than normal as per customer request.
Medium Voltage Cables

49

TABLE 3 - 6.35/11 KV 6.6/6.6 KV (UE) HT XLPE SINGLE CORE ALUMINIUM CONDUCTOR CABLES
TIRUPATI PLASTOMATICS" SINGLE CORE ALUMINIUM CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES
CONFORMING TO IS: 7098 PART-2/1985:
UNARMOURED CABLE
Nominal Nominal Approx. Approx.
Thickness Thickness Overall Weight
of XLPE of PVC Diameter
of
Insulation Outer
of
Cable
Sheath
Cable
mm
mm Kg/Km
Sq.mm. mm
Nominal
Size
of
Conductor

35
50
70
95
120
150
185
240
300
400
500
630
800
1000

3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6

2.0
2.0
2.0
2.0
2.0
2.0
2.2
2.2
2.2
2.2
2.4
2.4
2.6
2.8

21.7
22.8
24.8
25.8
27.7
29.4
31.8
35.4
36.3
39.2
42.7
46.3
50.2
55.3

554
603
705
802
953
1055
1254
1455
1654
2005
2455
2903
3504
4252

ALUMINIUM STRIP ARMOURED CABLE ALUMINIUM ROUND WIRE ARMOURED CABLE CURRENT CARRYING CAPACITY
Minimum
Minimum Approx. Approx. Nominal Minimum Approx. Approx.
In
In
In
Thickness Nominal Thickness Overall Weight Dimension Thickness Overall Weight of Ground at Duct at
Air
at
of Inner Dimension of PVC Diameter
of
of
of
PVC
Diameter
Cable.
30
C.
30
C.
40
C.
of
Sheath
Outer
of
Cable
Round
Outer
of
Strip
Sheath
Cable
Wire
Sheath
Cable
mm
mm
mm
mm Kg/Km mm
mm
mm Kg/Km Amps. Amps. Amps.
0.30
0.30
0.30
0.30
0.30
0.30
0.40
0.40
0.40
0.40
0.50
0.50
0.50
0.60

4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8

1.40
1.40
1.40
1.40
1.40
1.56
1.56
1.56
1.56
1.72
1.72
1.88
1.88
2.04

23.2
24.3
25.7
27.8
29.3
30.8
33.3
35.3
37.4
40.8
44.5
47.7
51.7
56.2

653
704
805
955
1055
1203
1404
1602
1854
2255
2653
3205
3805
4604

1.6
1.6
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.0
2.0
2.0
2.5
2.5

1.40
1.40
1.40
1.40
1.56
1.56
1.56
1.56
1.56
1.72
1.88
1.88
2.04
2.20

24.2
25.3
27.4
29.3
31.5
32.4
35.3
38.5
40.3
43.8
46.7
50.2
55.4
60.8

753
805
954
1053
1204
1352
1603
1855
2104
2555
3003
3454
4302
5155

120
140
175
205
235
260
295
340
385
440
495
560
620
680

105
125
155
180
205
230
260
300
335
380
430
480
530
580

145
170
215
260
305
345
395
470
540
630
730
840
960
1070

*Normal
Delivery
Length.
Mtrs.
500
500
500
500
500
500
500
500
500
500
500
500
500
500

TABLE 4 - 6.35/11 KV 6.6/6.6 KV (UE) HT XLPE SINGLE CORE COPPER CONDUCTOR CABLES
TIRUPATI PLASTOMATICS" SINGLE CORE COPPER CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES
CONFORMING TO IS: 7098 PART-2/1985:
UNARMOURED CABLE
Nominal Nominal Approx. Approx.
Thickness Thickness Overall Weight
of XLPE of PVC Diameter
of
Insulation Outer
of
Cable
Sheath
Cable
mm
mm Kg/Km
Sq.mm. mm
Nominal
Size
of
Conductor

35
50
70
95
120
150
185
240
300
400
500
630
800
1000

3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6

2.0
2.0
2.0
2.0
2.0
2.0
2.2
2.2
2.2
2.2
2.4
2.4
2.6
2.8

21.8
23.4
24.8
26.3
28.5
28.8
31.7
34.7
36.3
39.4
42.8
46.4
50.3
55.4

755
904
1152
1405
1654
1953
2405
2903
3502
4505
5503
6804
8452
10451

ALUMINIUM STRIP ARMOURED CABLE ALUMINIUM ROUND WIRE ARMOURED CABLE CURRENT CARRYING CAPACITY
Minimum
Minimum Approx. Approx. Nominal Minimum Approx. Approx.
In
In
In
Thickness Nominal Thickness Overall Weight Dimension Thickness Overall Weight of Ground at Duct at
Air
at
of Inner Dimension of PVC Diameter
of
of
of
PVC
Diameter
Cable.
30
C.
30
C.
40
C.
of
Sheath
Outer
of
Cable
Round
Outer
of
Strip
Sheath
Cable
Wire
Sheath
Cable
mm
mm
mm
mm Kg/Km mm
mm
mm Kg/Km Amps. Amps. Amps.
0.30
0.30
0.30
0.30
0.30
0.30
0.40
0.40
0.40
0.40
0.50
0.50
0.50
0.60

4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8

1.40
1.40
1.40
1.40
1.40
1.56
1.56
1.56
1.56
1.72
1.72
1.88
1.88
2.04

23.3
24.4
25.8
27.7
29.4
30.8
32.8
34.7
37.3
40.7
44.4
47.8
51.6
56.7

852
1005
1253
1555
1801
2152
2554
3103
3705
4752
5801
7104
8753
10805

1.6
1.6
1.6
1.6
1.6
1.6
2.0
2.0
2.0
2.0
2.0
2.0
2.5
2.5

1.40
1.40
1.40
1.40
1.56
1.56
1.56
1.56
1.56
1.72
1.88
1.88
2.04
2.20

The above data is approximate and subject to manufacturing tolerance.


* Delivery Length tolerance is
5% Length more than normal as per customer request.

50

Medium Voltage Cables

24.4
25.0
27.2
29.8
31.5
32.7
33.5
38.8
40.7
44.2
46.4
50.3
55.5
60.8

952
1115
1354
1653
1955
2251
2752
3354
3955
5053
6102
7354
9255
11353

155
185
225
265
300
335
380
435
490
550
610
680
740
790

140
160
195
235
265
295
330
380
425
480
530
580
630
670

185
220
275
340
390
440
510
600
680
790
910
1030
1140
1250

*Normal
Delivery
Length.
Mtrs.
500
500
500
500
500
500
500
500
500
500
500
500
500
500

TABLE 5 - 11 / 11 KV (UE) HT XLPE SINGLE CORE ALUMINIUM CONDUCTOR CABLES


TIRUPATI PLASTOMATICS" SINGLE CORE ALUMINIUM CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES
CONFORMING TO IS: 7098 PART-2/1985:
UNARMOURED CABLE
Nominal Nominal Approx. Approx.
Thickness Thickness Overall Weight
of XLPE of PVC Diameter
of
Insulation Outer
of
Cable
Sheath
Cable
mm
mm Kg/Km
Sq.mm. mm
Nominal
Size
of
Conductor

70
95
120
150
185
240
300
400
500
630
800
1000

5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5

2.0
2.0
2.2
2.2
2.2
2.2
2.2
2.4
2.4
2.6
2.8
2.8

28.7
30.2
32.3
33.8
35.7
37.7
39.8
42.9
45.6
50.3
54.4
59.2

855
983
1152
1264
1433
1655
1902
2305
2703
3204
3885
4604

ALUMINIUM STRIP ARMOURED CABLE ALUMINIUM ROUND WIRE ARMOURED CABLE CURRENT CARRYING CAPACITY
Minimum
Minimum Approx. Approx. Nominal Minimum Approx. Approx.
In
In
In
Thickness Nominal Thickness Overall Weight Dimension Thickness Overall Weight of Ground at Duct at
Air
at
of Inner Dimension of PVC Diameter
of
of
of
PVC
Diameter
Cable.
30
C.
30
C.
40
C.
of
Sheath
Outer
of
Cable
Round
Outer
of
Strip
Sheath
Cable
Wire
Sheath
Cable
mm
mm
mm
mm Kg/Km mm
mm
mm Kg/Km Amps. Amps. Amps.
0.30
0.30
0.40
0.40
0.40
0.40
0.40
0.50
0.50
0.50
0.60
0.60

4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8

1.56
1.56
1.56
1.56
1.56
1.56
1.72
1.72
1.88
1.88
2.04
2.2

30.3
32.5
33.8
35.4
36.8
38.5
41.7
45.3
48.4
51.8
56.4
61.3

1055
1204
1303
1455
1601
1852
2154
2603
3005
3504
4202
5003

1.6
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.5
2.5
2.5
2.5

1.56
1.56
1.56
1.56
1.56
1.72
1.72
1.88
2.04
2.04
2.2
2.36

31.4
34.2
36.4
37.3
39.5
41.8
44.3
47.4
52.3
55.4
60.5
65.2

1154
1355
1502
1655
1851
2153
2405
2904
3505
4052
4801
5653

175
205
235
260
295
340
385
440
495
560
620
680

155
180
205
230
260
300
335
380
430
480
530
580

215
260
305
345
395
470
540
630
730
840
960
1070

*Normal
Delivery
Length.
Mtrs.
500
500
500
500
500
500
500
500
500
500
500
500

TABLE 6 - 11 / 11 KV (UE) HT XLPE SINGLE CORE COPPER CONDUCTOR CABLES


TIRUPATI PLASTOMATICS" SINGLE CORE COPPER CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES
CONFORMING TO IS: 7098 PART-2/1985:
UNARMOURED CABLE
Nominal Nominal Approx. Approx.
Thickness Thickness Overall Weight
of XLPE of PVC Diameter
of
Insulation Outer
of
Cable
Sheath
Cable
mm
mm Kg/Km
Sq.mm. mm
Nominal
Size
of
Conductor

70
95
120
150
185
240
300
400
500
630
800
1000

5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5

2.0
2.0
2.2
2.2
2.2
2.2
2.2
2.4
2.4
2.6
2.8
2.8

28.2
30.3
31.8
33.2
35.8
37.3
39.4
43.5
46.2
50.3
54.4
59.3

1305
1553
1905
2202
2601
3154
3755
4803
5804
7103
8855
10804

ALUMINIUM STRIP ARMOURED CABLE ALUMINIUM ROUND WIRE ARMOURED CABLE CURRENT CARRYING CAPACITY
Minimum
Minimum Approx. Approx. Nominal Minimum Approx. Approx.
In
In
In
Thickness Nominal Thickness Overall Weight Dimension Thickness Overall Weight of Ground at Duct at
Air
at
of Inner Dimension of PVC Diameter
of
of
of
PVC
Diameter
Cable.
30
C.
30
C.
40
C.
of
Sheath
Outer
of
Cable
Round
Outer
of
Strip
Sheath
Cable
Wire
Sheath
Cable
mm
mm
mm
mm Kg/Km mm
mm
mm Kg/Km Amps. Amps. Amps.
0.30
0.30
0.40
0.40
0.40
0.40
0.40
0.50
0.50
0.50
0.60
0.60

4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8

1.56
1.56
1.56
1.56
1.56
1.56
1.72
1.72
1.88
1.88
2.04
2.2

29.7
32.4
33.3
35.1
37.3
39.4
41.8
45.4
48.3
51.7
56.2
61.4

1505
1803
2054
2402
2755
3351
4003
5105
6104
7403
9152
11205

1.6
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.5
2.5
2.5
2.5

1.56
1.56
1.56
1.56
1.56
1.72
1.72
1.88
2.04
2.04
2.2
2.36

31.7
34.2
36.3
37.4
39.5
42.2
44.3
47.4
52.5
55.3
60.4
65.2

1604
1955
2253
2602
3004
3653
4255
5405
6603
7952
9755
11854

225
265
300
335
380
435
490
550
610
680
740
790

195
235
265
295
330
380
425
480
530
580
630
670

275
340
390
440
510
600
680
790
910
1030
1140
1250

*Normal
Delivery
Length.
Mtrs.
500
500
500
500
500
500
500
500
500
500
500
500

The above data is approximate and subject to manufacturing tolerance.


* Delivery Length tolerance is
5% Length more than normal as per customer request.

Medium Voltage Cables

51

TABLE 7 - 12.7 / 22 KV HT XLPE SINGLE CORE ALUMINIUM CONDUCTOR CABLES


TIRUPATI PLASTOMATICS" SINGLE CORE ALUMINIUM CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES
CONFORMING TO IS: 7098 PART-2/1985:
UNARMOURED CABLE
Nominal Nominal Approx. Approx.
Thickness Thickness Overall Weight
of XLPE of PVC Diameter
of
Insulation Outer
of
Cable
Sheath
Cable
mm
mm Kg/Km
Sq.mm. mm
Nominal
Size
of
Conductor

95
120
150
185
240
300
400
500
630
800
1000

6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0

2.2
2.2
2.2
2.2
2.2
2.2
2.4
2.6
2.6
2.8
3.0

32.4
34.5
35.2
37.3
39.5
41.4
44.8
47.7
51.8
56.3
61.2

1105
1202
1353
1505
1751
2005
2404
2852
3303
4005
4804

ALUMINIUM STRIP ARMOURED CABLE ALUMINIUM ROUND WIRE ARMOURED CABLE CURRENT CARRYING CAPACITY
Minimum
Minimum Approx. Approx. Nominal Minimum Approx. Approx.
In
In
In
Thickness Nominal Thickness Overall Weight Dimension Thickness Overall Weight of Ground at Duct at
Air
at
of Inner Dimension of PVC Diameter
of
of
of
PVC
Diameter
Cable.
30
C.
30
C.
40
C.
of
Sheath
Outer
of
Cable
Round
Outer
of
Strip
Sheath
Cable
Wire
Sheath
Cable
mm
mm
mm
mm Kg/Km mm
mm
mm Kg/Km Amps. Amps. Amps.
0.40
0.40
0.40
0.40
0.40
0.40
0.50
0.50
0.50
0.60
0.60

4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8

1.56
1.56
1.56
1.56
1.56
1.72
1.88
1.88
2.04
2.04
2.2

33.2
35.4
36.3
38.5
40.8
43.4
47.3
50.2
54.5
58.3
62.1

1255
1402
1534
1703
1951
2255
2704
3102
3703
4352
5154

2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.5
2.5
2.5
2.5

1.56
1.56
1.56
1.72
1.72
1.72
1.88
2.04
2.04
2.20
2.36

36.2
37.8
39.2
41.4
43.3
45.4
49.5
53.8
57.2
61.5
66.4

1454
1605
1753
2002
2253
2505
3001
3652
4155
5004
5803

205
230
260
290
335
380
430
485
550
610
660

180
200
225
255
290
325
370
420
470
520
560

270
310
350
400
470
540
630
730
840
950
1060

*Normal
Delivery
Length.
Mtrs.
500
500
500
500
500
500
500
500
500
500
500

TABLE 8 - 12.7 / 22 KV HT XLPE SINGLE CORE COPPER CONDUCTOR CABLES


TIRUPATI PLASTOMATICS" SINGLE CORE COPPER CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES
CONFORMING TO IS: 7098 PART-2/1985:
UNARMOURED CABLE
Nominal Nominal Approx. Approx.
Thickness Thickness Overall Weight
of XLPE of PVC Diameter
of
Insulation Outer
of
Cable
Sheath
Cable
mm
mm Kg/Km
Sq.mm. mm
Nominal
Size
of
Conductor

95
120
150
185
240
300
400
500
630
800
1000

6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0

2.2
2.2
2.2
2.2
2.2
2.2
2.4
2.6
2.6
2.8
3.0

32.2
34.4
35.3
36.6
38.3
40.8
44.8
47.7
51.8
56.3
61.2

1655
1953
2257
2653
3205
3854
4905
5952
7203
8955
11004

ALUMINIUM STRIP ARMOURED CABLE ALUMINIUM ROUND WIRE ARMOURED CABLE CURRENT CARRYING CAPACITY
Minimum
Minimum Approx. Approx. Nominal Minimum Approx. Approx.
In
In
In
Thickness Nominal Thickness Overall Weight Dimension Thickness Overall Weight of Ground at Duct at
Air
at
of Inner Dimension of PVC Diameter
of
of
of
PVC
Diameter
Cable.
30
C.
30
C.
40
C.
of
Sheath
Outer
of
Cable
Round
Outer
of
Strip
Sheath
Cable
Wire
Sheath
Cable
mm
mm
mm
mm Kg/Km mm
mm
mm Kg/Km Amps. Amps. Amps.
0.40
0.40
0.40
0.40
0.40
0.40
0.50
0.50
0.50
0.60
0.60

4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8

1.56
1.56
1.56
1.56
1.56
1.72
1.88
1.88
2.04
2.04
2.20

32.7
34.8
36.3
38.5
40.8
43.2
46.8
50.3
54.4
57.8
62.7

1853
2152
2455
2854
3455
4102
5203
6204
7605
9303
11355

2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.5
2.5
2.5
2.5

1.56
1.56
1.56
1.72
1.72
1.72
1.88
2.04
2.04
2.20
2.36

The above data is approximate and subject to manufacturing tolerance.


* Delivery Length tolerance is
5% Length more than normal as per customer request.

52

Medium Voltage Cables

36.2
37.7
39.4
41.5
43.3
45.4
49.5
53.8
57.3
61.4
66.5

2054
2355
2703
3155
3752
4354
5503
6755
8052
9904
12005

265
300
330
375
430
480
540
600
660
720
760

230
260
290
325
370
415
465
520
570
620
660

345
400
450
510
600
690
790
910
1020
1140
1240

*Normal
Delivery
Length.
Mtrs.
500
500
500
500
500
500
500
500
500
500
500

TABLE 9 - 19 / 33 KV HT XLPE SINGLE CORE ALUMINIUM CONDUCTOR CABLES


TIRUPATI PLASTOMATICS" SINGLE CORE ALUMINIUM CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES
CONFORMING TO IS: 7098 PART-2/1985:
UNARMOURED CABLE
Nominal Nominal Approx. Approx.
Thickness Thickness Overall Weight
of XLPE of PVC Diameter
of
Insulation Outer
of
Cable
Sheath
Cable
mm
mm Kg/Km
Sq.mm. mm
Nominal
Size
of
Conductor

95
120
150
185
240
300
400
500
630
800
1000

8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0
8.0

2.2
2.2
2.2
2.4
2.4
2.6
2.6
2.8
2.8
3.0
3.2

37.8
39.4
40.3
43.4
45.1
48.5
51.3
54.2
57.4
62.3
67.5

1405
1553
1704
1905
2202
2504
2903
3405
3902
4605
5452

ALUMINIUM STRIP ARMOURED CABLE ALUMINIUM ROUND WIRE ARMOURED CABLE CURRENT CARRYING CAPACITY
Minimum
Minimum Approx. Approx. Nominal Minimum Approx. Approx.
In
In
In
Thickness Nominal Thickness Overall Weight Dimension Thickness Overall Weight of Ground at Duct at
Air
at
of Inner Dimension of PVC Diameter
of
of
of
PVC
Diameter
Cable.
30
C.
30
C.
40
C.
of
Sheath
Outer
of
Cable
Round
Outer
of
Strip
Sheath
Cable
Wire
Sheath
Cable
mm
mm
mm
mm Kg/Km mm
mm
mm Kg/Km Amps. Amps. Amps.
0.40
0.40
0.40
0.50
0.50
0.50
0.50
0.60
0.60
0.60
0.70

4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8

1.56
1.72
1.72
1.72
1.88
1.88
2.04
2.04
2.2
2.36
2.36

39.3
41.2
42.5
44.8
47.7
48.5
52.8
56.3
60.4
64.3
69.4

1602
1804
1955
2203
2505
2754
3255
3705
4303
5054
5903

2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.5
2.5
2.5
2.5

1.72
1.72
1.72
1.88
1.88
2.04
2.04
2.2
2.36
2.36
2.52

41.8
43.2
44.7
47.3
49.8
52.2
55.3
60.4
63.5
67.3
72.8

1905
2054
2203
2501
2764
3103
3555
4254
4903
5605
6553

200
230
260
290
335
380
430
485
550
610
660

180
200
225
255
290
325
370
420
470
520
560

270
310
350
400
470
540
630
730
840
950
1060

*Normal
Delivery
Length.
Mtrs.
500
500
500
500
500
500
500
500
500
500
500

TABLE 10 - 19 / 33 KV HT XLPE SINGLE CORE COPPER CONDUCTOR CABLES


TIRUPATI PLASTOMATICS" SINGLE CORE COPPER CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES
CONFORMING TO IS: 7098 PART-2/1985:
UNARMOURED CABLE
Nominal Nominal Approx. Approx.
Thickness Thickness Overall Weight
of XLPE of PVC Diameter
of
Insulation Outer
of
Cable
Sheath
Cable
mm
mm Kg/Km
Sq.mm. mm
Nominal
Size
of
Conductor

95
120
150
185
240
300
400
500
630
800
1000

8.8
8.8
8.8
8.8
8.8
8.8
8.8
8.8
8.8
8.8
8.8

2.2
2.2
2.2
2.4
2.4
2.6
2.6
2.8
2.8
3.0
3.2

37.7
39.3
40.5
43.4
45.2
48.5
51.4
54.3
57.8
62.7
67.4

2005
2303
2602
3055
3654
4353
5355
6454
7003
9555
11604

ALUMINIUM STRIP ARMOURED CABLE ALUMINIUM ROUND WIRE ARMOURED CABLE CURRENT CARRYING CAPACITY
Minimum
Minimum Approx. Approx. Nominal Minimum Approx. Approx.
In
In
In
Thickness Nominal Thickness Overall Weight Dimension Thickness Overall Weight of Ground at Duct at
Air
at
of Inner Dimension of PVC Diameter
of
of
of
PVC
Diameter
Cable.
30
C.
30
C.
40
C.
of
Sheath
Outer
of
Cable
Round
Outer
of
Strip
Sheath
Cable
Wire
Sheath
Cable
mm
mm
mm
mm Kg/Km mm
mm
mm Kg/Km Amps. Amps. Amps.
0.40
0.40
0.40
0.50
0.50
0.50
0.50
0.60
0.60
0.60
0.70

4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8

1.56
1.72
1.72
1.72
1.88
1.88
2.04
2.04
2.20
2.36
2.36

39.2
41.3
42.5
44.8
47.4
49.3
52.2
56.4
60.5
64.3
69.4

2205
2553
2854
3305
4003
4605
5702
6803
8205
10003
12104

2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.5
2.5
2.5
2.5

1.72
1.72
1.72
1.88
1.88
2.04
2.04
2.20
2.36
2.36
2.52

41.8
43.3
44.8
47.5
49.8
52.4
55.3
60.2
63.4
67.3
72.8

2555
2803
3102
3655
4254
4951
6052
7354
8805
10603
12752

265
300
330
375
430
480
540
600
660
720
760

230
260
290
325
370
415
465
520
570
620
660

345
400
450
510
600
690
790
910
1020
1140
1240

*Normal
Delivery
Length.
Mtrs.
500
500
500
500
500
500
500
500
500
500
500

The above data is approximate and subject to manufacturing tolerance.


* Delivery Length tolerance is
5% Length more than normal as per customer request.

Medium Voltage Cables

53

TABLE 11 - 33 / 33 KV (UE) HT XLPE SINGLE CORE ALUMINIUM CONDUCTOR CABLES


TIRUPATI PLASTOMATICS" SINGLE CORE ALUMINIUM CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES
CONFORMING TO IS: 7098 PART-2/1985:
UNARMOURED CABLE
Nominal Nominal Approx. Approx.
Thickness Thickness Overall Weight
of XLPE of PVC Diameter
of
Insulation Outer
of
Cable
Sheath
Cable
mm
mm Kg/Km
Sq.mm. mm
Nominal
Size
of
Conductor

120
150
185
240
300
400
500
630
800
1000

9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5

2.2
2.4
2.4
2.4
2.6
2.6
2.8
3.0
3.0
3.2

41.8
43.2
45.3
47.7
50.4
53.2
56.8
60.4
64.3
69.5

1705
1903
2104
2352
2653
3104
3603
4205
4853
5705

ALUMINIUM STRIP ARMOURED CABLE ALUMINIUM ROUND WIRE ARMOURED CABLE CURRENT CARRYING CAPACITY
Minimum
Minimum Approx. Approx. Nominal Minimum Approx. Approx.
In
In
In
Thickness Nominal Thickness Overall Weight Dimension Thickness Overall Weight of Ground at Duct at
Air
at
of Inner Dimension of PVC Diameter
of
of
of
PVC
Diameter
Cable.
30
C.
30
C.
40
C.
of
Sheath
Outer
of
Cable
Round
Outer
of
Strip
Sheath
Cable
Wire
Sheath
Cable
mm
mm
mm
mm Kg/Km mm
mm
mm Kg/Km Amps. Amps. Amps.
0.40
0.40
0.50
0.50
0.50
0.50
0.60
0.60
0.60
0.70

4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8

1.72
1.72
1.72
1.88
1.88
2.04
2.04
2.20
2.36
2.52

43.2
44.7
46.8
49.2
51.3
55.4
58.3
61.7
66.4
71.2

2005
2153
2404
2705
3002
3455
3953
4554
5305
6253

2.00
2.00
2.00
2.50
2.50
2.50
2.50
2.50
3.15
3.15

1.72
1.88
1.88
2.04
2.04
2.20
2.20
2.36
2.52
2.68

45.7
47.8
49.8
53.3
55.2
58.7
62.2
65.3
71.2
76.4

2253
2502
2704
3205
3502
4003
4552
5205
6204
7255

230
260
290
335
380
430
485
550
610
660

200
225
255
290
325
370
420
470
520
560

310
350
400
470
540
630
730
840
950
1060

*Normal
Delivery
Length.
Mtrs.
500
500
500
500
500
500
500
500
500
500

TABLE 12 - 33 / 33 KV (UE) HT XLPE SINGLE CORE COPPER CONDUCTOR CABLES


TIRUPATI PLASTOMATICS" SINGLE CORE COPPER CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES
CONFORMING TO IS: 7098 PART-2/1985:
UNARMOURED CABLE
Nominal Nominal Approx. Approx.
Thickness Thickness Overall Weight
of XLPE of PVC Diameter
of
Insulation Outer
of
Cable
Sheath
Cable
mm
mm Kg/Km
Sq.mm. mm
Nominal
Size
of
Conductor

120
150
185
240
300
400
500
630
800
1000

9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5
9.5

2.2
2.4
2.4
2.4
2.6
2.6
2.8
3.0
3.0
3.2

41.8
43.3
45.4
47.7
50.2
53.4
56.2
60.3
64.4
68.8

2453
2854
3255
3852
4555
5603
6704
8105
9803
11902

ALUMINIUM STRIP ARMOURED CABLE ALUMINIUM ROUND WIRE ARMOURED CABLE CURRENT CARRYING CAPACITY
Minimum
Minimum Approx. Approx. Nominal Minimum Approx. Approx.
In
In
In
Thickness Nominal Thickness Overall Weight Dimension Thickness Overall Weight of Ground at Duct at
Air
at
of Inner Dimension of PVC Diameter
of
of
of
PVC
Diameter
Cable.
30
C.
30
C.
40
C.
of
Sheath
Outer
of
Cable
Round
Outer
of
Strip
Sheath
Cable
Wire
Sheath
Cable
mm
mm
mm
mm Kg/Km mm
mm
mm Kg/Km Amps. Amps. Amps.
0.40
0.40
0.50
0.50
0.50
0.50
0.60
0.60
0.60
0.70

4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8

1.72
1.72
1.72
1.88
1.88
2.04
2.04
2.20
2.36
2.52

43.2
44.8
46.7
49.2
51.1
55.3
58.4
61.8
66.3
71.2

2752
3055
3503
4204
4851
5955
7054
8453
10254
12455

2.00
2.00
2.00
2.50
2.50
2.50
2.50
2.50
3.15
3.15

1.72
1.88
1.88
2.04
2.04
2.20
2.20
2.36
2.52
2.68

The above data is approximate and subject to manufacturing tolerance.


* Delivery Length tolerance is
5% Length more than normal as per customer request.

54

Medium Voltage Cables

45.8
47.2
49.4
53.5
55.3
58.7
62.2
65.7
71.2
76.3

3005
3402
3851
4654
5353
6505
7652
9105
11203
13452

300
330
375
430
480
540
600
660
720
760

260
290
325
370
415
465
520
570
620
660

400
450
510
600
690
790
910
1020
1140
1240

*Normal
Delivery
Length.
Mtrs.
500
500
500
500
500
250
250
250
250
200

TABLE 13 - 1.9 / 3.3 KV (E) & 3.3/3.3 KV (UE) HT XLPE THREE CORE ALUMINIUM CONDUCTOR CABLES
TIRUPATI PLASTOMATICS" THREE CORE ALUMINIUM CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES
CONFORMING TO IS: 7098 PART-2/1985:
UNARMOURED CABLE
STEEL STRIP ARMOURED CABLE STEEL ROUND WIRE ARMOURED CABLE CURRENT CARRYING CAPACITY
Nominal
Nominal Approx. Approx.
Minimum Approx. Approx. Nominal Minimum Approx. Approx.
In
In
In
Thickness Minimum Thickness Overall Weight Nominal Thickness Overall Weight Dimension Thickness Overall Weight of Ground at Duct at
Air
at
Dimension
of XLPE Thickness of PVC Diameter
of
of PVC Diameter
of
of
of
PVC
Diameter
Cable.
30
C.
30
C.
40
C.
of
Insulation of Inner
Outer
of
Cable
Outer
of
Cable
Round
Outer
of
Strip
Sheath
Sheath
Cable
Sheath
Cable
Wire
Sheath
Cable
mm
mm
mm Kg/Km mm
mm
mm Kg/Km mm
mm
mm Kg/Km Amps. Amps. Amps.
Sq.mm. mm
Nominal
Size
of
Conductor

35
50
70
95
120
150
185
240
300
400

2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

0.4
0.4
0.5
0.5
0.5
0.6
0.6
0.7
0.7
0.7

2.2
2.2
2.4
2.6
2.6
2.8
3.0
3.0
3.2
3.6

38.5
40.2
44.7
48.3
52.2
55.7
60.3
65.5
70.7
78.3

1502
1703
2155
2604
3001
3503
4155
4904
5853
7302

4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8

1.56
1.72
1.72
1.80
2.04
2.04
2.20
2.36
2.52
2.68

37.2
39.7
44.5
47.8
51.3
54.7
59.2
64.7
70.5
76.7

1955
2204
2653
3152
3651
4105
4804
5752
6655
8102

2.0
2.0
2.0
2.5
2.5
2.5
2.5
2.5
3.15
3.15

1.72
1.72
1.88
2.04
2.04
2.20
2.36
2.36
2.68
2.84

40.4
42.2
47.2
51.3
55.7
58.8
63.4
68.2
75.3
82.4

2605
2903
3451
4404
5002
5555
6353
7354
9255
11002

115
130
160
190
220
245
275
315
355
400

97
115
140
165
190
210
240
275
310
350

*Normal
Delivery
Length.
Mtrs.

125
150
190
230
260
295
335
395
450
520

500
500
500
500
500
500
500
500
500
500

TABLE 14 - 1.9 / 3.3 KV (E) & 3.3/3.3 KV (UE) HT XLPE THREE CORE COPPER CONDUCTOR CABLES
TIRUPATI PLASTOMATICS" THREE CORE COPPER CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES
CONFORMING TO IS: 7098 PART-2/1985:
UNARMOURED CABLE
STEEL STRIP ARMOURED CABLE STEEL ROUND WIRE ARMOURED CABLE CURRENT CARRYING CAPACITY
Nominal
Nominal Approx. Approx.
Minimum Approx. Approx. Nominal Minimum Approx. Approx.
In
In
In
Thickness Minimum Thickness Overall Weight Nominal Thickness Overall Weight Dimension Thickness Overall Weight of Ground at Duct at
Air
at
Dimension
of XLPE Thickness of PVC Diameter
of
of PVC Diameter
of
of
of
PVC
Diameter
Cable.
30
C.
30
C.
40
C.
of
Insulation of Inner Outer
of
Cable
Outer
of
Cable
Round
Outer
of
Strip
Sheath
Sheath
Cable
Sheath
Cable
Wire
Sheath
Cable
mm
mm
mm Kg/Km mm
mm
mm Kg/Km mm
mm
mm Kg/Km Amps. Amps. Amps.
Sq.mm. mm
Nominal
Size
of
Conductor

35
50
70
95
120
150
185
240
300
400

2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2
2.2

0.4
0.4
0.5
0.5
0.5
0.6
0.6
0.7
0.7
0.7

2.2
2.2
2.4
2.6
2.6
2.8
3.0
3.0
3.2
3.6

38.2
40.4
44.8
48.7
52.2
55.3
60.5
65.4
70.2
78.4

2152
2653
3455
4354
5252
6303
7602
9354
11405
14753

4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8

1.56
1.72
1.72
1.80
2.04
2.04
2.2
2.36
2.52
2.68

37.2
39.7
44.2
47.3
51.2
54.6
59.2
64.7
70.3
76.2

2605
3153
3954
4951
5902
6905
8252
10253
12254
15555

2.00
2.00
2.00
2.50
2.50
2.50
2.50
2.50
3.15
3.15

1.72
1.72
1.88
2.04
2.04
2.20
2.36
2.36
2.68
2.84

40.2
42.1
47.2
51.4
55.7
58.6
63.2
68.3
75.4
82.5

3255
3803
4755
6152
72001
8355
9803
11804
14855
18452

145
170
210
250
280
310
350
400
445
500

125
150
180
215
240
270
305
350
390
440

165
195
240
295
335
380
430
500
510
650

*Normal
Delivery
Length.
Mtrs.
500
500
500
500
500
500
500
500
500
250

The above data is approximate and subject to manufacturing tolerance.


* Delivery Length tolerance is
5% Length more than normal as per customer request.

Medium Voltage Cables

55

TABLE 15 - 3.8 / 6.6 KV (E) HT XLPE THREE CORE ALUMINIUM CONDUCTOR CABLES
TIRUPATI PLASTOMATICS" THREE CORE ALUMINIUM CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES
CONFORMING TO IS: 7098 PART-2/1985:
UNARMOURED CABLE
STEEL STRIP ARMOURED CABLE STEEL ROUND WIRE ARMOURED CABLE CURRENT CARRYING CAPACITY
Nominal
Nominal Approx. Approx.
Minimum Approx. Approx. Nominal Minimum Approx. Approx.
In
In
In
Thickness Minimum Thickness Overall Weight Nominal Thickness Overall Weight Dimension Thickness Overall Weight of Ground at Duct at
Air
at
Dimension
of XLPE Thickness of PVC Diameter
of
of PVC Diameter
of
of
of
PVC
Diameter
Cable.
30
C.
30
C.
40
C.
of
Insulation of Inner Outer
of
Cable
Outer
of
Cable
Round
Outer
of
Strip
Sheath
Sheath
Cable
Sheath
Cable
Wire
Sheath
Cable
mm
mm
mm Kg/Km mm
mm
mm Kg/Km mm
mm
mm Kg/Km Amps. Amps. Amps.
Sq.mm. mm
Nominal
Size
of
Conductor

35
50
70
95
120
150
185
240
300
400

2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
3.0
3.3

0.4
0.5
0.5
0.5
0.5
0.6
0.6
0.7
0.7
0.7

2.2
2.4
2.6
2.6
2.8
2.8
3.0
3.2
3.4
3.8

40.2
43.4
47.5
51.2
55.3
58.4
63.1
68.3
74.5
83.2

1603
1954
2352
2805
3303
3801
4402
5304
6305
8003

4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8

1.72
1.72
1.88
1.88
2.04
2.20
2.20
2.36
2.52
2.84

40.2
42.7
47.3
50.8
55.2
58.4
62.3
67.8
73.8
82.2

2202
2504
3003
3402
4005
4502
5154
6103
7165
9002

2.00
2.00
2.00
2.50
2.50
2.50
2.50
3.15
3.15
4.00

1.72
1.88
1.88
2.04
2.20
2.20
2.36
2.52
2.68
3.00

43.2
45.7
49.8
54.2
58.1
61.4
66.3
73.5
78.3
89.2

2805
3203
3704
4705
5402
5905
6703
8604
9903
13205

115
130
160
190
220
245
275
315
355
400

97
115
140
165
190
210
240
275
310
350

*Normal
Delivery
Length.
Mtrs.

125
150
190
230
260
295
335
395
450
520

500
500
500
500
500
500
500
500
500
500

TABLE 16 - 3.8 / 6.6 KV (E) HT XLPE THREE CORE COPPER CONDUCTOR CABLES
TIRUPATI PLASTOMATICS" THREE CORE COPPER CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES
CONFORMING TO IS: 7098 PART-2/1985:
UNARMOURED CABLE
STEEL STRIP ARMOURED CABLE STEEL ROUND WIRE ARMOURED CABLE CURRENT CARRYING CAPACITY
Nominal
Nominal Approx. Approx.
Minimum Approx. Approx. Nominal Minimum Approx. Approx.
In
In
In
Thickness Minimum Thickness Overall Weight Nominal Thickness Overall Weight Dimension Thickness Overall Weight of Ground at Duct at
Air
at
Dimension
of XLPE Thickness of PVC Diameter
of
of PVC Diameter
of
of
of
PVC
Diameter
Cable.
30
C.
30
C.
40
C.
of
Insulation of Inner Outer
of
Cable
Outer
of
Cable
Round
Outer
of
Strip
Sheath
Sheath
Cable
Sheath
Cable
Wire
Sheath
Cable
mm
mm
mm Kg/Km mm
mm
mm Kg/Km mm
mm
mm Kg/Km Amps. Amps. Amps.
Sq.mm. mm
Nominal
Size
of
Conductor

35
50
70
95
120
150
185
240
300
400

2.8
2.8
2.8
2.8
2.8
2.8
2.8
2.8
3.0
3.3

0.4
0.5
0.5
0.5
0.5
0.6
0.6
0.7
0.7
0.7

2.2
2.4
2.6
2.6
2.8
2.8
3.0
3.2
3.4
3.8

40.4
43.2
47.5
51.3
55.5
58.3
63.5
68.3
74.4
83.5

2255
2852
3654
4553
5505
6552
7854
9801
11902
15405

4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8

1.72
1.72
1.88
1.88
2.04
2.20
2.20
2.36
2.52
2.84

40.0
42.5
47.5
50.5
55.0
58.0
65.0
67.0
73.5
82.5

2855
3400
4260
5210
6210
7260
8610
10560
12760
16410

2.00
2.00
2.00
2.50
2.50
2.50
2.50
3.15
3.15
3.15

1.72
1.88
1.88
2.04
2.20
2.20
2.36
2.52
2.68
3.00

The above data is approximate and subject to manufacturing tolerance.


* Delivery Length tolerance is
5% Length more than normal as per customer request.

56

Medium Voltage Cables

43.0
45.5
49.5
54.0
58.5
61.0
66.0
73.5
79.0
89.5

3460
4150
5010
6500
7600
8700
10160
13060
15450
20660

145
170
210
250
280
310
350
400
445
500

125
150
180
215
240
270
305
350
390
440

165
195
240
295
335
380
430
500
510
650

*Normal
Delivery
Length.
Mtrs.
500
500
500
500
500
500
500
500
500
250

TABLE 17 - 6.35 / 11 KV (E) HT XLPE THREE CORE ALUMINIUM CONDUCTOR CABLES


TIRUPATI PLASTOMATICS" THREE CORE ALUMINIUM CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES
CONFORMING TO IS: 7098 PART-2/1985:
UNARMOURED CABLE
STEEL STRIP ARMOURED CABLE STEEL ROUND WIRE ARMOURED CABLE CURRENT CARRYING CAPACITY
Nominal
Nominal Approx. Approx.
Minimum Approx. Approx. Nominal Minimum Approx. Approx.
In
In
In
Thickness Minimum Thickness Overall Weight Nominal Thickness Overall Weight Dimension Thickness Overall Weight of Ground at Duct at
Air
at
Dimension
of XLPE Thickness of PVC Diameter
of
of PVC Diameter
of
of
of
PVC
Diameter
Cable.
30
C.
30
C.
40
C.
of
Insulation of Inner Outer
of
Cable
Outer
of
Cable
Round
Outer
of
Strip
Sheath
Sheath
Cable
Sheath
Cable
Wire
Sheath
Cable
mm
mm
mm Kg/Km mm
mm
mm Kg/Km mm
mm
mm Kg/Km Amps. Amps. Amps.
Sq.mm. mm
Nominal
Size
of
Conductor

35
50
70
95
120
150
185
240
300
400

3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6

0.5
0.5
0.5
0.6
0.6
0.6
0.7
0.7
0.7
0.7

2.4
2.6
2.6
2.8
2.8
3.0
3.2
3.4
3.6
3.8

43.7
46.2
50.3
54.7
58.3
61.2
66.4
71.8
76.7
83.2

1952
2254
2655
3153
3602
4105
4853
5702
6655
8104

4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8

1.72
1.72
1.88
1.88
2.04
2.20
2.20
2.36
2.52
2.84

44.2
46.7
50.6
54.8
58.2
61.3
66.5
71.7
76.6
83.2

2252
2853
3305
3854
4402
4901
5653
6604
7602
9105

2.00
2.50
2.50
2.50
2.50
2.50
3.15
3.15
3.15
4.00

1.88
2.04
2.04
2.20
2.20
2.36
2.52
2.68
2.84
3.00

45.7
49.8
53.2
58.3
61.8
64.2
71.4
76.3
81.5
90.3

3255
4003
4602
5254
5853
6453
8103
9255
10403
13454

115
130
160
190
220
245
275
315
355
400

97
115
140
165
190
210
240
275
310
350

*Normal
Delivery
Length.
Mtrs.

125
150
190
230
260
295
335
395
450
520

500
500
500
500
500
500
500
500
250
250

TABLE 18 - 6.35 / 11 KV (E) HT XLPE THREE CORE COPPER CONDUCTOR CABLES


TIRUPATI PLASTOMATICS" THREE CORE COPPER CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES
CONFORMING TO IS: 7098 PART-2/1985:
UNARMOURED CABLE
STEEL STRIP ARMOURED CABLE STEEL ROUND WIRE ARMOURED CABLE CURRENT CARRYING CAPACITY
Nominal
Nominal Approx. Approx.
Minimum Approx. Approx. Nominal Minimum Approx. Approx.
In
In
In
Thickness Minimum Thickness Overall Weight Nominal Thickness Overall Weight Dimension Thickness Overall Weight of Ground at Duct at
Air
at
Dimension
of XLPE Thickness of PVC Diameter
of
of PVC Diameter
of
of
of
PVC
Diameter
Cable.
30
C.
30
C.
40
C.
of
Insulation of Inner Outer
of
Cable
Outer
of
Cable
Round
Outer
of
Strip
Sheath
Sheath
Cable
Sheath
Cable
Wire
Sheath
Cable
mm
mm
mm Kg/Km mm
mm
mm Kg/Km mm
mm
mm Kg/Km Amps. Amps. Amps.
Sq.mm. mm
Nominal
Size
of
Conductor

35
50
70
95
120
150
185
240
300
400

3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6

0.5
0.5
0.5
0.6
0.6
0.6
0.7
0.7
0.7
0.7

2.4
2.6
2.6
2.8
2.8
3.0
3.2
3.4
3.6
3.8

43.7
46.2
50.8
54.3
58.4
61.2
66.4
71.2
76.7
83.8

2602
3155
3953
4951
5854
6905
8303
10202
12202
15554

4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8

1.72
1.88
1.88
2.04
2.20
2.20
2.36
2.52
2.68
2.84

44.2
46.7
50.3
54.1
58.8
61.2
66.3
71.1
76.4
83.7

3152
3755
4601
5603
6654
7655
9103
11052
13154
16555

2.00
2.50
2.50
2.50
2.50
2.50
3.15
3.15
3.15
4.00

1.88
2.04
2.04
2.20
2.20
2.36
2.52
2.68
2.84
3.00

45.2
49.3
53.6
58.2
61.7
64.8
71.2
76.3
81.4
90.2

3905
4953
5904
7002
8103
9255
11553
13704
15955
20903

145
170
210
250
280
310
350
400
445
500

125
150
180
215
240
270
305
350
390
440

165
195
240
295
335
380
430
500
510
650

*Normal
Delivery
Length.
Mtrs.
500
500
500
500
500
500
500
250
250
250

The above data is approximate and subject to manufacturing tolerance.


* Delivery Length tolerance is
5% Length more than normal as per customer request.

Medium Voltage Cables

57

TABLE 19 - 11 / 11 KV (UE) HT XLPE THREE CORE ALUMINIUM CONDUCTOR CABLES


TIRUPATI PLASTOMATICS" THREE CORE ALUMINIUM CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES
CONFORMING TO IS: 7098 PART-2/1985:
UNARMOURED CABLE
STEEL STRIP ARMOURED CABLE STEEL ROUND WIRE ARMOURED CABLE CURRENT CARRYING CAPACITY
Nominal
Nominal Approx. Approx.
Minimum Approx. Approx. Nominal Minimum Approx. Approx.
In
In
In
Thickness Minimum Thickness Overall Weight Nominal Thickness Overall Weight Dimension Thickness Overall Weight of Ground at Duct at
Air
at
Dimension
of XLPE Thickness of PVC Diameter
of
of PVC Diameter
of
of
of
PVC
Diameter
Cable.
30
C.
30
C.
40
C.
of
Insulation of Inner Outer
of
Cable
Outer
of
Cable
Round
Outer
of
Strip
Sheath
Sheath
Cable
Sheath
Cable
Wire
Sheath
Cable
mm
mm
mm Kg/Km mm
mm
mm Kg/Km mm
mm
mm Kg/Km Amps. Amps. Amps.
Sq.mm. mm
Nominal
Size
of
Conductor

70
95
120
150
185
240
300
400

5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5

0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7

3.0
3.2
3.2
3.4
3.4
3.6
3.8
4.0

59.8
63.2
67.3
70.7
74.8
80.1
85.2
92.4

3552
4104
4653
5205
5902
6853
7855
9404

4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8

2.20
2.36
2.36
2.52
2.68
2.84
3.00
3.00

59.7
63.2
67.4
70.2
74.1
80.2
85.3
92.5

4305
4903
5504
6105
6952
7903
8954
10505

2.50
3.15
3.15
3.15
3.15
3.15
4.00
4.00

2.36
2.52
2.52
2.68
2.84
3.00
3.00
3.00

63.2
68.7
72.2
75.4
80.3
85.5
91.2
98.4

5905
7253
8004
8653
9652
10851
13254
15202

160
190
220
245
275
315
355
400

140
165
190
210
240
275
310
350

*Normal
Delivery
Length.
Mtrs.

190
230
260
295
335
395
450
520

500
500
500
500
500
250
250
250

TABLE 20 - 11 / 11 KV (UE) HT XLPE THREE CORE COPPER CONDUCTOR CABLES


TIRUPATI PLASTOMATICS" THREE CORE COPPER CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES
CONFORMING TO IS: 7098 PART-2/1985:
UNARMOURED CABLE
STEEL STRIP ARMOURED CABLE STEEL ROUND WIRE ARMOURED CABLE CURRENT CARRYING CAPACITY
Nominal
Nominal Approx. Approx.
Minimum Approx. Approx. Nominal Minimum Approx. Approx.
In
In
In
Thickness Minimum Thickness Overall Weight Nominal Thickness Overall Weight Dimension Thickness Overall Weight of Ground at Duct at
Air
at
Dimension
of XLPE Thickness of PVC Diameter
of
of
PVC
Diameter
of
of
of
PVC
Diameter
Cable.
30
C.
30
C.
40
C.
of
Insulation of Inner Outer
of
Cable
Outer
of
Cable
Round
Outer
of
Sheath
Strip
Sheath
Cable
Sheath
Cable
Wire
Sheath
Cable
mm
mm
mm Kg/Km mm
mm
mm Kg/Km mm
mm
mm Kg/Km Amps. Amps. Amps.
Sq.mm. mm
Nominal
Size
of
Conductor

70
95
120
150
185
240
300
400

5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5

0.6
0.6
0.7
0.7
0.7
0.7
0.7
0.7

3.0
3.2
3.2
3.4
3.4
3.6
3.8
4.0

59.7
63.2
67.3
70.8
74.1
80.2
85.4
92.3

4905
5903
6904
8002
9301
11304
13405
16853

4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8

2.20
2.36
2.36
2.52
2.68
2.84
3.00
3.00

59.2
63.4
67.3
70.1
74.2
80.4
85.3
92.4

5605
6702
7754
8902
10303
12355
14504
17952

2.50
3.15
3.15
3.15
3.15
3.15
4.00
4.00

2.36
2.52
2.52
2.68
2.84
3.00
3.00
3.00

The above data is approximate and subject to manufacturing tolerance.


* Delivery Length tolerance is
5% Length more than normal as per customer request.

58

Medium Voltage Cables

63.2
68.3
72.4
75.5
80.1
85.2
91.4
98.5

7155
9003
10254
11452
13105
15353
18852
22654

210
250
280
310
350
400
445
500

180
215
240
270
305
350
390
440

240
295
335
380
430
500
570
650

*Normal
Delivery
Length.
Mtrs.
500
500
500
500
250
250
250
250

TABLE 21 - 12.7 / 22 KV (E) HT XLPE THREE CORE ALUMINIUM CONDUCTOR CABLES


TIRUPATI PLASTOMATICS" THREE CORE ALUMINIUM CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES
CONFORMING TO IS: 7098 PART-2/1985:
UNARMOURED CABLE
STEEL STRIP ARMOURED CABLE STEEL ROUND WIRE ARMOURED CABLE CURRENT CARRYING CAPACITY
Nominal
Nominal Approx. Approx.
Minimum Approx. Approx. Nominal Minimum Approx. Approx.
In
In
In
Thickness Minimum Thickness Overall Weight Nominal Thickness Overall Weight Dimension Thickness Overall Weight of Ground at Duct at
Air
at
Dimension
of XLPE Thickness of PVC Diameter
of
of PVC Diameter
of
of
of
PVC
Diameter
Cable.
30
C.
30
C.
40
C.
of
Insulation of Inner Outer
of
Cable
Outer
of
Cable
Round
Outer
of
Strip
Sheath
Sheath
Cable
Sheath
Cable
Wire
Sheath
Cable
mm
mm
mm Kg/Km mm
mm
mm Kg/Km mm
mm
mm Kg/Km Amps. Amps. Amps.
Sq.mm. mm
Nominal
Size
of
Conductor

95
120
150
185
240
300
400

6.0
6.0
6.0
6.0
6.0
6.0
6.0

0.7
0.7
0.7
0.7
0.7
0.7
0.7

3.2
3.4
3.4
3.6
3.8
4.0
4.0

66.2
70.1
72.4
77.2
82.3
87.2
94.8

4455
5052
5554
6301
7303
8305
9852

4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8

2.36
2.52
2.68
2.68
2.84
3.00
3.00

66.2
70.1
72.7
77.6
82.8
87.2
94.3

5305
5902
6503
7251
8304
9355
10952

3.15
3.15
3.15
3.15
4.00
4.00
4.00

2.52
2.68
2.68
2.84
3.00
3.00
3.00

71.2
75.3
77.4
82.2
89.1
93.4
100.5

7755
8502
9204
10151
12602
13854
15803

190
215
240
270
310
350
395

170
190
215
240
275
310
355

*Normal
Delivery
Length.
Mtrs.
500
500
250
250
250
250
250

230
265
300
340
400
455
530

TABLE 22 - 12.7 / 22 KV (E) HT XLPE THREE CORE COPPER CONDUCTOR CABLES


TIRUPATI PLASTOMATICS" THREE CORE COPPER CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES
CONFORMING TO IS: 7098 PART-2/1985:
UNARMOURED CABLE
STEEL STRIP ARMOURED CABLE STEEL ROUND WIRE ARMOURED CABLE CURRENT CARRYING CAPACITY
Nominal
Nominal Approx. Approx.
Minimum Approx. Approx. Nominal Minimum Approx. Approx.
In
In
In
Thickness Minimum Thickness Overall Weight Nominal Thickness Overall Weight Dimension Thickness Overall Weight of Ground at Duct at
Air
at
Dimension
of XLPE Thickness of PVC Diameter
of
of PVC Diameter
of
of
of
PVC
Diameter
Cable.
30
C.
30
C.
40
C.
of
Insulation of Inner Outer
of
Cable
Outer
of
Cable
Round
Outer
of
Strip
Sheath
Sheath
Cable
Sheath
Cable
Wire
Sheath
Cable
mm
mm
mm Kg/Km mm
mm
mm Kg/Km mm
mm
mm Kg/Km Amps. Amps. Amps.
Sq.mm. mm
Nominal
Size
of
Conductor

95
120
150
185
240
300
400

6.0
6.0
6.0
6.0
6.0
6.0
6.0

0.7
0.7
0.7
0.7
0.7
0.7
0.7

3.2
3.4
3.4
3.6
3.8
4.0
4.0

66.2
70.1
72.7
77.8
82.2
87.1
94.6

6205
7302
8303
9754
11752
13901
17255

4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8

2.36
2.52
2.68
2.68
2.84
3.00
3.00

66.2
70.1
72.3
77.2
82.8
87.7
94.2

7052
8155
9302
10704
12752
14951
18403

3.15
3.15
3.15
3.15
4.00
4.00
4.00

2.52
2.68
2.68
2.84
3.00
3.00
3.00

71.2
75.1
77.8
82.3
89.2
93.7
100.2

9505
10752
11954
13605
17053
19404
23252

245
275
305
345
395
440
495

215
245
275
305
350
390
440

300
340
385
435
510
580
660

*Normal
Delivery
Length.
Mtrs.
500
500
250
250
250
250
200

The above data is approximate and subject to manufacturing tolerance.


* Delivery Length tolerance is
5% Length more than normal as per customer request.

Medium Voltage Cables

59

TABLE 23 - 19 / 33 KV (E) HT XLPE THREE CORE ALUMINIUM CONDUCTOR CABLES


TIRUPATI PLASTOMATICS" THREE CORE ALUMINIUM CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES
CONFORMING TO IS: 7098 PART-2/1985:
UNARMOURED CABLE
STEEL STRIP ARMOURED CABLE STEEL ROUND WIRE ARMOURED CABLE CURRENT CARRYING CAPACITY
Nominal
Nominal Approx. Approx.
Minimum Approx. Approx. Nominal Minimum Approx. Approx.
In
In
In
Thickness Minimum Thickness Overall Weight Nominal Thickness Overall Weight Dimension Thickness Overall Weight of Ground at Duct at
Air
at
Dimension
of XLPE Thickness of PVC Diameter
of
of PVC Diameter
of
of
of
PVC
Diameter
Cable.
30
C.
30
C.
40
C.
of
Insulation of Inner
Outer
of
Cable
Outer
of
Cable
Round
Outer
of
Strip
Sheath
Sheath
Cable
Sheath
Cable
Wire
Sheath
Cable
mm
mm
mm Kg/Km mm
mm
mm Kg/Km mm
mm
mm Kg/Km Amps. Amps. Amps.
Sq.mm. mm
Nominal
Size
of
Conductor

95
120
150
185
240
300
400

8.8
8.8
8.8
8.8
8.8
8.8
8.8

0.7
0.7
0.7
0.7
0.7
0.7
0.7

3.6
3.8
4.0
4.0
4.0
4.0
4.0

79.1 6055 4 x 0.8


83.2 6752 4 x 0.8
86.3 7403 4 x 0.8
90.7 8154 4 x 0.8
95.8 9155 4 x 0.8
100.2 10201 4 x 0.8
106.3 11802 4 x 0.8

2.84
2.84
3.00
3.00
3.00
3.00
3.00

79.2 7105
83.4 7752
86.8 8403
90.2 9252
95.1 10304
100.2 11355
106.3 13102

3.15
4.00
4.00
4.00
4.00
4.00
4.00

3.0
3.0
3.0
3.0
3.0
3.0
3.0

84.1
89.3
92.2
96.4
101.2
105.1
112.3

10055
12102
12803
13904
15152
16455
18552

190
215
240
270
310
350
395

170
190
215
240
275
310
355

*Normal
Delivery
Length.
Mtrs.
500
500
250
250
250
250
250

230
265
300
340
400
455
530

TABLE 24 - 19 / 33 KV (E) HT XLPE THREE CORE COPPER CONDUCTOR CABLES


TIRUPATI PLASTOMATICS" THREE CORE COPPER CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES
CONFORMING TO IS: 7098 PART-2/1985:
UNARMOURED CABLE
STEEL STRIP ARMOURED CABLE STEEL ROUND WIRE ARMOURED CABLE CURRENT CARRYING CAPACITY
Nominal
Nominal Approx. Approx.
Minimum Approx. Approx. Nominal Minimum Approx. Approx.
In
In
In
Thickness Minimum Thickness Overall Weight Nominal Thickness Overall Weight Dimension Thickness Overall Weight of Ground at Duct at
Air
at
Dimension
of XLPE Thickness of PVC Diameter
of
of PVC Diameter
of
of
of
PVC
Diameter
Cable.
30
C.
30
C.
40
C.
of
Insulation of Inner Outer
of
Cable
Outer
of
Cable
Round
Outer
of
Strip
Sheath
Sheath
Cable
Sheath
Cable
Wire
Sheath
Cable
mm
mm
mm Kg/Km mm
mm
mm Kg/Km mm
mm
mm Kg/Km Amps. Amps. Amps.
Sq.mm. mm
Nominal
Size
of
Conductor

95
120
150
185
240
300
400

8.8
8.8
8.8
8.8
8.8
8.8
8.8

0.7
0.7
0.7
0.7
0.7
0.7
0.7

3.6
3.8
4.0
4.0
4.0
4.0
4.0

79.5
83.3
86.8
90.7
95.6
100.4
106.8

7857
9008
10153
11604
13603
15755
19254

4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8

2.84
2.84
3.00
3.00
3.00
3.00
3.00

79.2
83.4
86.8
90.3
95.7
100.2
106.3

8904
1005
11202
12705
14753
16954
20555

3.15
4.00
4.00
4.00
4.00
4.00
4.00

3.0
3.0
3.0
3.0
3.0
3.0
3.0

The above data is approximate and subject to manufacturing tolerance.


* Delivery Length tolerance is
5% Length more than normal as per customer request.

60

Medium Voltage Cables

84.4
89.8
92.2
96.7
101.3
105.7
112.8

11805
14302
15604
17301
19605
22003
26002

245
275
305
345
395
440
495

215
245
275
305
350
390
440

300
340
385
435
510
580
660

*Normal
Delivery
Length.
Mtrs.
250
250
250
250
250
200
200

TABLE 25 - 33 / 33 KV (UE) HT XLPE THREE CORE ALUMINIUM CONDUCTOR CABLES


TIRUPATI PLASTOMATICS" THREE CORE ALUMINIUM CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES
CONFORMING TO IS: 7098 PART-2/1985:
UNARMOURED CABLE
STEEL STRIP ARMOURED CABLE STEEL ROUND WIRE ARMOURED CABLE CURRENT CARRYING CAPACITY
Nominal
Nominal Approx. Approx.
Minimum Approx. Approx. Nominal Minimum Approx. Approx.
In
In
In
Thickness Minimum Thickness Overall Weight Nominal Thickness Overall Weight Dimension Thickness Overall Weight of Ground at Duct at
Air
at
Dimension
of XLPE Thickness of PVC Diameter
of
of PVC Diameter
of
of
of
PVC
Diameter
Cable.
30
C.
30
C.
40
C.
of
Insulation of Inner Outer
of
Cable
Outer
of
Cable
Round
Outer
of
Strip
Sheath
Sheath
Cable
Sheath
Cable
Wire
Sheath
Cable
mm
mm
mm Kg/Km mm
mm
mm Kg/Km mm
mm
mm Kg/Km Amps. Amps. Amps.
Sq.mm. mm
Nominal
Size
of
Conductor

120
150
185
240
300
400

9.5
9.5
9.5
9.5
9.5
9.5

0.7
0.7
0.7
0.7
0.7
0.7

4.0
4.0
4.0
4.0
4.0
4.0

88.2 7605 4 x 0.8


91.4 8152 4 x 0.8
95.7 8954 4 x 0.8
100.3 1005 4 x 0.8
105.2 11053 4 x 0.8
111.1 12752 4 x 0.8

3.0
3.0
3.0
3.0
3.0
3.0

88.8
91.2
95.7
100.1
105.3
111.2

8655
9253
10104
11205
12303
14104

4.0
4.0
4.0
4.0
4.0
4.0

3.0
3.0
3.0
3.0
3.0
3.0

94.2
97.3
101.5
106.3
110.2
117.4

12705
13453
14552
15853
17304
19355

215
240
270
310
350
395

190
215
240
275
310
355

*Normal
Delivery
Length.
Mtrs.

265
300
340
400
455
530

500
250
250
250
250
250

TABLE 26 - 33 / 33 KV (UE) HT XLPE THREE CORE COPPER CONDUCTOR CABLES


TIRUPATI PLASTOMATICS" THREE CORE COPPER CONDUCTOR, XLPE INSULATED, UNARMOURED & ARMOURED CABLES
CONFORMING TO IS: 7098 PART-2/1985:
UNARMOURED CABLE
STEEL STRIP ARMOURED CABLE STEEL ROUND WIRE ARMOURED CABLE CURRENT CARRYING CAPACITY
Nominal
Nominal Approx. Approx.
Minimum Approx. Approx. Nominal Minimum Approx. Approx.
In
In
In
Thickness Minimum Thickness Overall Weight Nominal Thickness Overall Weight Dimension Thickness Overall Weight of Ground at Duct at
Air
at
Dimension
of XLPE Thickness of PVC Diameter
of
of PVC Diameter
of
of
of
PVC
Diameter
Cable.
30
C.
30
C.
40
C.
of
Insulation of Inner Outer
of
Cable
Outer
of
Cable
Round
Outer
of
Strip
Sheath
Sheath
Cable
Sheath
Cable
Wire
Sheath
Cable
mm
mm
mm Kg/Km mm
mm
mm Kg/Km mm
mm
mm Kg/Km Amps. Amps. Amps.
Sq.mm. mm
Nominal
Size
of
Conductor

120
150
185
240
300
400

9.5
9.5
9.5
9.5
9.5
9.5

0.7
0.7
0.7
0.7
0.7
0.7

4.0
4.0
4.0
4.0
4.0
4.0

88.8
91.2
95.6
100.7
105.3
111.1

9805
10952
12403
14454
16652
20153

4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8
4 x 0.8

3.0
3.0
3.0
3.0
3.0
3.0

88.1
91.2
95.7
100.3
105.2
111.8

10855
12003
13552
15654
17905
21553

4.0
4.0
4.0
4.0
4.0
4.0

3.0
3.0
3.0
3.0
3.0
3.0

94.2
97.4
101.5
106.2
110.8
117.2

14953
16254
18002
20305
22903
26752

275
305
345
395
440
495

245
275
305
350
390
440

340
385
435
510
580
660

*Normal
Delivery
Length.
Mtrs.
500
250
250
250
200
200

The above data is approximate and subject to manufacturing tolerance.


* Delivery Length tolerance is
5% Length more than normal as per customer request.

Medium Voltage Cables

61

Handling, Storage and Laying of HT Cables.


A.

CABLE INSPECTION

B.

Inspect every cable reet for damage before


accepting the shipment. Be particularly alert for
cable damage if :

Damage to cables can occur due to the incorrect


handling to which the drums and cables may be subjected;
causing breakdown of the drum flanges and in exceptional
cases, movement of the drum barrel takes place. Once this
breakdown of the drum occurs, the cable damaged during
handling & storage can cause service failures when the
subject cable is put to use.

1.

A reel is lying flat on its side

2.

Several reels are stacked

3.

Other freight is stacked on a reel

4.

Nails have been driven into reel flanges to secure


shipping blocks

5.

A reel flange is damaged

6.

A cable covering is removed, stained or damaged

7.

A cable end seal is removed or damaged. A reel


has been dropped (hidden damage likely)

Do's

62

CABLE HANDLING & STORAGE

Thus the following is a list of Do's and Don'ts that should be


followed while handling and storing the cables before it is
put to use.

Don'ts

When off loading reels from a truck, lower


reel carefully using a hydraulic gate, hoist
or forklift truck

Never drop reels. If reels must be rolled,


roll in opposite direction of the cable
wraps to keep cable from loosening on the
reel.

If a fork lift is used, approach the reel from


the flange side. Position the forks such
that the reel is lifted by both reel flanges.
Also Consideration should be given to,
Traffic patterns during off-loading &
damage during the time in storage

Do not allow the lift forks to contact the


cable. Care must be taken by the fork lift
operator not to make sudden turns or
stops.

Cable reels should be stored on hard


surfaces resting on the flanges edge
(Flanges vertical). Align reels flange to
flange and, if possible arrange so that first
in is first out.

Multiple reels stacked on top of each other


("Pancake" Storage is not recommended)
for cble drums. The weight of the stack
can total thousands of kgs. creating an
enormous load on the bottom reel. Also,
damage to the reel and/or cable will likely
occur when the reel is flipped for transit. A
concentration of stress on the reel flange
may cause it to break and subsequently
damage the cable.

When using a hoist, install a mandrel


through the reel arbor holes and attach a
sling. Use spreader bar approximately 6
inches longer than the overall reel width
placed between the sling ends just above
the reel flanges.

This may lead to the bending of the reel


flanges and mashing the cable

Medium Voltage Cables

C.

PRE-INSTALLATION

4.

To ensure safety during cable Installation following


shall be checked prior to installation.

Shaft supported both ends with sultable


jacks/stands.

5.

Under no circumstances the cable winding


shall be lifted off a coil or drum lying flat at the
flanges. This would cause serious twist and
damages.

6.

Suitable protection shall be provided to the


cables against mechanical damages, it
includes covers, pipes etc.

1.

The cable selected is proper for designed


application.

2.

The cable has not been damaged in transit or


storage.

Review all applicable state and national codes to


verify that the cable chosen is appropriate for the
job. Also consult your local electricity authority.
Next, you must identify any existing cable damage
and prevent any further damaged from occurring.
This is done through proper cable inspection,
handling and storage.

D.

INSTALLATION & LAYING


Mechanical stresses during installation are
generally more severe than those encountered
while in service. Thus care should be taken as
regards to the following while installation and
laying of cables.
1.

Tirupati Plastomatics recommend the laying


and installation of cables as per IS : 1255/84.

2.

Care shall be taken during laying to avoid


sharp bending, and twisting.

3.

Cable shall be un wound from the drum by


lifting the drum on the center

E.

RECOMMENDED MINIMUM BENDING


RADIUS FOR HEAVY DUTY CABLES.
Single Core

20 x D

Multicore

15 x D

Where D= Diameter of cable in mm

F.

RECOMMENDED SAFE PULLING


FORCE WITH STOCKINGS :
a)

For Unarmoured Cable : P = 5D2


Where P = Pulling Force

b)

For Armoured Cable : P = 9D2


Where D = Diameter of cable in mm

G.

RECOMMENDED SAFE PULLING


FORCE WHEN PULLED WITH PULLING
EYE :
a)

For Aluminium Conductors : 30 N / mm2

b)

For Copper Conductor

: 50 N / mm2

DO NOT ATTEMPT "COILING" OF CABLE ON THE GROUND

ON THE GROUND CABLE CAN BE FLAKED IN A FIGURE OF EIGHT FORMATION

Medium Voltage Cables

63

EARTHED

UNEARTHED SYSTEM :

In the initial years, the generators and transformers were


having capacities of few MVA and hence fault current was
also less. The star point or neutral point was solidly
grounded and this is called earthed system.

Today generators of 500 MVA capacity are in commercial


use. More over several mega power stations are connected
to grid. Due to this, the fault level has increased
tremendously. In case of an earth fault, a heavy current
flows in to the fault and this may damage the costly
generators and power transformers.

R
N

To reduce the fault current, the star point is connected to


the earth through a resistance or a reactance as under.

R
N

EARTH

VR

In this system if an earth fault occurs on any of the phase,


the voltages of other two healthy phases with respect to the
earth remain the same.

64

Medium Voltage Cables

In this case if an earth fault occurs on R phase, the voltage


of the faulty phase with respect to the earth (R) appears
across across the current limiting resistance or reactance
in the earth circuit of the star point and as a result the
voltage of the star point which was at eath potential under
normal conditions rises to VR. Due to this the voltages of
other two healthy phases (B and Y) with respect to the earth
rises by 1.7 times (Vector sum of VR and VB). If the
insulation of these phases are not designed for these
increased voltages they may develop earth fault. This is
called Unearthed System.

Conversion Table
Multiply

by

to obtain

WEIGHT - Imperial
Ounce ________________ 28.3495
Pounds (Av) ___________ 453.59
Pounds (Av) ___________ 0.45359
Pounds (Av) ___________ 907.19
Tons
(Long) ________ 1016.05

grams
grams
kilograms
kilograms
kilograms

WEIGHTS - Metric
Grams ________________ 0.03527
Grams ________________ 0.002205
Kilograms _____________ 35.274
Kilograms _____________ 2.2046
Kilograms _____________ 0.001102
Kilograms _____________ 0.0009842

ounces
pounds
ounces
pounds
tons (short)
tons (long)

MISCELLANEOUS - Imperial
Pounds per 1000 feet ___ 1.48816
Pounds per mile ______ 0.28185
Pounds per square inch_ 0.0007031
Pounds per square inch _ 0.07031
Feet per second ______ 18.288
Feet per second ______ 1.09728
Mils per hour _________1.60935
Ohms per mile__________ 0.62137
Decibels per 1000 feet ___ 3.28083
Decibels per mile ________ 0.62137
Decibels ________________ 0.1153

MISCELLANEOUS - Metric
Kilograms per kilometer __ 0.67197
Kilograms per kilometer __ 3.54795
kilograms per square
millimeter _______________ 1422.34
Kilograms per square
centimeter ______________ 14.2234
Grams per cubic cm _____ 0.03613
Meters per minute _______ 0.05468
Kilometer per hour ______ 0.91134
Kilometer per hour _______ 0.62137
Ohms per kilometer______ 0.3048
Ohms per kilometer ______ 1.6093
Decibels per kilometer ____ 0.3048
Decibels per kilometer ____ 1.6093

TEMPERATURE
Fahrenheit ___________ 5/9 (oF)-32
Celsius ______________ 9/5 (oC)+32

kilograms per kilometer


kilograms per kilometers
kilograms per
square millimeters
kilograms per
square centimeter
meters per minute
kilometers per hour
kilometers per hour
ohms per kilometer
decibels per kilometer
decibels per kilometer
nepers

pounds per 1000 feet


pounds per mile
pounds per squar inch
pounds per square inch
pounds per cubic inch
feet per second
feet per second
miles per hour
ohms per 1000 f eet
ohms per mile
decibels per 1000 feet
decibels per mile

Celsius
Fahrenheit

Multiply

by

to obtain

LENGTH - Imperial
Mils __________________
Mils __________________
Inches ________________
Inches ________________
Inches ________________
Feet __________________
Feet __________________
Feet (thousand of) _______
Yards _________________
Mils ___________________

0.001
0.0254
1000
25.40
2.54
30.48
0.3048
0.3048
0.9144
1.6093

inches
millimeters
mils
millimeters
centimeters
centimeters
meters
kilometers
meters
kilometers

LENGTH - Imperial
Millimeters ______________
Millimeters ______________
Centimeters _____________
Meters _________________
Centimeters _____________
Meters _________________
Meters _________________
Meters _________________
Kilometers ______________
Kilometers ______________

39.37
0.03937
0.3937
39.37
0.032808
39.37
3.2808
1.0936
3280.83
0.62137

mils
inches
inches
inches
feet
inches
feet
yards
feet
mils

AREA - Imperial
Square mils ______________
Square mils ______________
Circular mils _____________
Circular mils _____________
Circular mils _____________
Square inches____________
Square inches ___________
Square inches ___________
Square inches ___________
Square inches ___________
Square inches ___________

1.2732
0.000001
0.7854
0.0000007854
0.00050657
1000000
1273240
645.16
6.4516
0.09290
0.8361

circular mils
square inches
square mils
square inches
square millimeters
square mils
Circular mils
square millimeters
square centimeters
square meters
square meters

AREA - Metric
Square millimeters ________
Square millimeters ________
Square centimeters _______
Square meters ___________
Square meters ___________

1973.52
0.00155
0.155
10.7638
1.19599

circular mils
square inches
square inches
square feet
square yards

VOLUME - Imperial
Cubic inches ____________
Cubic feet ______________

16.38716
0.028317

cubic meters
cubic meters

VOLUME - U.S.
Quarts (liquid) ____________ 0.9463
Gallaons ________________ 3.7854

cubic centimeters
cubic meters

VOLUME - Metric
Cubic centimeters ________
Cubic meters ____________
Liters __________________
Liters __________________

cubic inches
cubic feet
quarts (Liquid U.S.)
gallons (U.S.)

0.06102
35.3145
1.05668
0.26417

Medium Voltage Cables

65

CERTIFICATES

CERTIFICATES

CERTIFICATES

CERTIFICATES

CLIENTS

ACCROSS GLOBE

UAE

Afganistan
Nepal
India

Ethopia
Uganda Kenya

Sri Lanka

Cango

Malavi
Zambia
Botswana

South Africa

biq

Angola

ue

Tanzania
Mo
zam

Ghana

Mauritius

Butan
Myanmar

(Integrated Management System (IMS) Certified Company)

Corporate Office
B-141 (A), Road No. 9-D, V.K.I. Area, Jaipur-302013,
Rajasthan, INDIA
:
:
:
:

+91 141 2332902, 2331030, 2330305, 2330427


+91 141 2331808, 2260073
contact@tirupatiplastomatics.com
www.tirupatiplastomatics.com

Printed by : Hareshwar Printers # 9829066769

Phone
Fax
Email
Web

Brand Name:

QUALITY
ASSURED
COMPANY

ENVIRONMENTAL
MANAGEMENT
SYSTEM

SAFETY
ASSURED
COMPANY

ISO 9001:2008

ISO 14001:2008

OHSAS 18001:2007

Copyright 2011 Tirupati Plastomatics Pvt. Ltd. All Rights Reserved