Documente Academic
Documente Profesional
Documente Cultură
www.hilti.com.sg
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:
Engineer 360
Collin
|
Page:
Project:
Fastening Point:
Date:
1
9/3/2015
Specifier's comments:
1 Input data
Anchor type and size:
Material:
Approval No.:
ETA 11/0374
Issued I Valid:
7/19/2012 | 7/19/2017
Proof:
Stand-off installation:
eb = 0 mm (no stand-off); t = 8 mm
Baseplate:
S 235 (St 37); E = 210000.00 N/mm2; fyk = 235.00 N/mm2; gMs = 1.100
lx x ly x t = 200 mm x 150 mm x 8 mm; (Recommended plate thickness: calculated (6 mm))
Profile:
Base material:
Reinforcement:
No reinforcement or Reinforcement spacing >= 150 mm (any ) or >= 100 mm ( <= 10 mm)
no longitudinal edge reinforcement
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com.sg
Page:
Project:
Fastening Point:
Date:
Engineer 360
Collin
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:
9/3/2015
3
Shear force y
0.000
0.000
0.000
0.000
Tension
x
Compression
Steel failure*
Pull-out failure*
Concrete cone failure**
Splitting failure**
* most unfavourable anchor
Capacity [kN]
20.000
Utilisation bN [%]
18
Status
OK
N/A
N/A
N/A
N/A
7.923
22.803
35
OK
7.923
28.215
29
OK
NRd,s [kN]
20.000
NSd [kN]
3.449
Ac,N [mm2]
48400
A0c,N [mm2]
14400
yA,N
3.361
ccr,N [mm]
60
scr,N [mm]
120
ec1,N [mm]
37
yec1,N
0.618
ec2,N [mm]
0
yec2,N
1.000
ys,N
1.000
yre,N
1.000
N0Rk,c [kN]
16.463
gM,c
1.500
NRd,c [kN]
22.803
NSd [kN]
7.923
Ac,N [mm2]
84100
A0c,N [mm2]
36100
yA,N
2.330
ccr,sp [mm]
95
scr,sp [mm]
190
yh,sp
1.534
ec1,N [mm]
37
yec1,N
0.719
ec2,N [mm]
0
yec2,N
1.000
ys,N
1.000
yre,N
1.000
N0Rk,c [kN]
16.463
gM,sp
1.500
NRd,sp [kN]
28.215
NSd [kN]
7.923
NRk,s [kN]
28.000
3.2 Concrete cone failure
k1
11.000
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
k1
11.000
www.hilti.com.sg
Page:
Project:
Fastening Point:
Date:
Engineer 360
Collin
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:
9/3/2015
Capacity [kN]
15.120
Utilisation bV [%]
25
Status
OK
N/A
N/A
N/A
N/A
Pryout failure**
15.000
88.536
17
OK
7.500
12.114
62
OK
gM,s
1.250
VRd,s [kN]
15.120
VSd [kN]
3.750
Ac,N [mm2]
48400
A0c,N [mm2]
14400
yA,N
3.361
ccr,N [mm]
60
scr,N [mm]
120
k4
2.400
ec1,V [mm]
0
yec1,N
1.000
ec2,V [mm]
0
yec2,N
1.000
ys,N
1.000
yre,N
1.000
N0Rk,c [kN]
16.463
gM,c,p
1.500
VRd,c1 [kN]
88.536
VSd [kN]
15.000
dnom [mm]
10.0
kV
2.400
a
0.045
c1 [mm]
200
Ac,V [mm2]
150000
A0c,V [mm2]
180000
yA,V
0.833
ys,V
0.800
yh,V
1.000
ya,V
1.000
ec,V [mm]
0
yec,V
1.000
V0Rk,c [kN]
54.514
n1
2
gM,c
1.500
VRd,c [kN]
12.114
VSd [kN]
7.500
b
0.055
yre,V
1.000
y90,V
2.000
5 Combined tension and shear loads SOFA (fib (07/2011), section 10.3)
steel
concrete
a
bN
a
bV
bN
0.172
bV
0.248
a
2.000
Status
OK
0.347
0.619
1.500
70
OK
<= 1
2.555 [kN]
dN
0.168 [mm]
VSk
2.778 [kN]
dV
0.514 [mm]
dNV
0.541 [mm]
2.555 [kN]
dN
0.335 [mm]
VSk
2.778 [kN]
dV
0.772 [mm]
dNV
0.841 [mm]
Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements
are valid without friction between the concrete and the baseplate! The gap due to the drilled hole and clearance hole tolerances are not
included in this calculation!
The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.com.sg
Page:
Project:
Fastening Point:
Date:
Engineer 360
Collin
Company:
Specifier:
Address:
Phone I Fax:
E-Mail:
9/3/2015
8 Installation data
Baseplate, steel: S 235 (St 37); E = 210000.00 N/mm2; fyk = 235.00 N/mm2 Anchor type and size: HSA M10 hnom1
Profile: Rectangular hollow; 150 x 50 x 4 mm
Installation torque: 0.025 kNm
Hole diameter in the fixture: df = 12 mm
Hole diameter in the base material: 10 mm
Plate thickness (input): 8 mm
Hole depth in the base material: 55 mm
Recommended plate thickness: calculated (6 mm)
Minimum thickness of the base material: 100 mm
Cleaning: Manual cleaning of the drilled hole according to instructions for use is required.
Cleaning
Manual blow-out pump
100
25
100
Setting
Dynamic set
Installation torque control bar with suitable
screw driver or torque wrench
Hammer
100
75
75
2
25
50
100
x
-50
50
-50
50
y
-50
-50
50
50
c-x
100
200
100
200
c+x
200
100
200
100
c-y
-
c+y
200
200
100
100
Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
50