Sunteți pe pagina 1din 4

Job Title

Software Consultants (Pty) Ltd


Internet: http://www.prokon.com
E-Mail : mail@prokon.com

Client
Calcs by

KTP/10/13
NEW FUTURA
M/s KTP CONSULATNTS PTE LTD
Checked by
HT
T&T

N-35PC10

Design code : CP65 - 1999

Input tables
General design parameters:

X/Radius or
Bar dia. (mm)

Y (mm)
Angle ()

5.000
190.000
5.000

5.000
990.000

-5.000

5.000

-190.000
-5.000

-5.000
-990.000

43.000

16

157.000

16

157.000

16

43.000

16

43.000

16.000

157.000

16.000

43.000

16.000

157.000

16.000

43.000

16.000

157.000

16.000

43.000

16.000

157.000

16.000

43.000

16.000

157.000

16.000

Job Number
Job Title

Date

Software Consultants (Pty) Ltd


Internet: http://www.prokon.com
E-Mail : mail@prokon.com

OCT 2015
C13

General column design by PROKON.

Code

Sheet

43.000

(GenCol Ver W2.6.11 - 24 Apr 2014)

Client
Calcs by

Sheet

KTP/10/13
NEW FUTURA
M/s KTP CONSULATNTS PTE LTD
Checked by
HT
T&T

Date

OCT 2015

Design loads:
Load
case

Designation

Ultimate limit state design loads


P (kN)

Mx top (kNm) My top (kNm) Mx bot (kNm) My bot (kNm)

Axial

1480

Axial + Mecc

1480

38

19

Axial + Mxx

1480

148

38

Axial + Myy

1480

38

19

Axial + Mxx + Myy


1480

148

75

CP65 - 1999

1000

General design parameters:


Given:
Lo = 2.000 m
fcu = 35 MPa
fy = 460 MPa
Ac = 197135 mm
Assumptions:
(1) The general conditions of clause 3.8.1 are applicable.
(2) The specified design axial loads include
the self-weight of the column.
(3) The design axial loads are taken constant
over the height of the column.

500
X

Job Number

43.000
957.000
957.000
195.333
195.333
347.667

Design approach:
The column is designed using the following procedure:
(1) The column design charts are constructed.
(2) The design axis and design ultimate moment are determined .
(3) The design axial force and moment capacity is checked on
the relevant design chart.
(4) The procedure is repeated for each load case.
(5) The critical load case is identified as the case yielding the lowest
safety factor about the design axis
Through inspection:
Load case 5 (Axial + Mxx + Myy) is critical.

347.667

Check column slenderness:


500.000
500.000

End fixity and bracing for bending about the Design axis:
At the top end: Condition 2 (partially fixed).
At the bottom end: Condition 3 (pinned).
The column is braced.

652.333

Effective length factor = 1.00

652.333

Effective column height:


le = . Lo

804.667
804.667

= 1 2
= 2.000 m

Table 3.21

Job Number

KTP/10/13
NEW FUTURA
Software Consultants (Pty) Ltd
Client
M/s KTP CONSULATNTS PTE LTD
Internet: http://www.prokon.com
Calcs by
Checked by
E-Mail : mail@prokon.com
HT
T&T
Column slenderness about weakest axis:

Sheet

Job Number

max_s140l =
=

Sheet

KTP/10/13
NEW FUTURA
Software Consultants (Pty) Ltd
Client
M/s KTP CONSULATNTS PTE LTD
Internet: http://www.prokon.com
Calcs by
Checked by
E-Mail : mail@prokon.com
HT
T&T
The initial end moments about the Y-Y axis:

Job Title

Job Title

Date

OCT 2015

Date

OCT 2015

M1 = Smaller initial end moment = 0.0 kNm

le
h

M2 = Larger initial end moment = 75.0 kNm

2
.19998

The initial moment near mid-height of the column :

3.8.3.2

Mi = - 0.4 . M1 + 0.6 . M2

= 10.001

= - 0.4 0 + 0.6 75
Where h is an equivalent column depth derived from the radius of gyration*square root of 12

= 45.000 kNm

Minimum Moments for Design:


Check for mininum eccentricity:
Check that the eccentricity exceeds the minimum in the plane of bending:
Use emin = 20mm

3.8.2.4

Mi2 = 0.4 . M2
= 0.4 75
= 30.000 kNm

Mmin = emin. N

Mi 0.4M2 = 45.0 kNm

= .01 1480

Design ultimate load and moment:

= 14.800 kNm

Design axial load:


Pu = 1480.0 kN

Check if the column is slender:


le/h = 10.0 < 15
The column is short.

3.8.1.3

Moments as a result of imperfections added about Design axis

5.8.9 2)

Moments about X-X axis( kNm)

Initial moments:

Mx=148.0 kNm
Mxmin=29.6 kNm

Mxtop=148.0 kNm

The initial end moments about the X-X axis:


M1 = Smaller initial end moment = 0.0 kNm

M2 = Larger initial end moment = 148.0 kNm


The initial moment near mid-height of the column :

3.8.3.2

Mi = - 0.4 . M1 + 0.6 . M2
= - 0.4 0 + 0.6 148
= 88.800 kNm

Initial

Additional

Moments as a result of imperfections added about Design axis


Mi2 = 0.4 . M2
= 0.4 148
= 59.200 kNm

Mi 0.4M2 = 88.8 kNm

Design

5.8.9 2)

Job Number
Job Title
Software Consultants (Pty) Ltd
Internet: http://www.prokon.com
E-Mail : mail@prokon.com

Client
Calcs by

Sheet

KTP/10/13
NEW FUTURA
M/s KTP CONSULATNTS PTE LTD
Checked by
HT
T&T

Job Number
Job Title

Date

OCT 2015

Software Consultants (Pty) Ltd


Internet: http://www.prokon.com
E-Mail : mail@prokon.com

Client
Calcs by

Sheet

KTP/10/13
NEW FUTURA
M/s KTP CONSULATNTS PTE LTD
Checked by
HT
T&T

Date

OCT 2015

Stresses at the top end of the column for the critical load case 5
Moments about Y-Y axis( kNm)

My=75.0 kNm
Mymin=14.8 kNm

Mytop=75.0 kNm

CP65 - 1999

1000
Initial

Additional

Design

Design of column section for ULS:

26.9
500
X

X
D

The column is checked for applied moment about the design axis.
Through inspection: the critical section lies at the top end of the column.
The design axis for the critical load case 5 lies at an angle of 26.87 to the X-axis
The safety factor for the critical load case 5 is 2.11
For bending about the design axis:

Bending moment (kNm)

600

500

400

300

200

100

0.00

-100

166 kNm

-200
-400
-600
-800
-1000

-200

-300

-400

-500

-600

1480 kN

Moment max = 578.0kNm @ 1366kN

Interaction Diagram

Axial load (kN)

4000
3800
3600
3400
3200
3000
2800
2600
2400
2200
2000
1800
1600
1400
1200
1000
800
600
400
200

Summary of design calculations:


Design table for critical load case:
Moments and Reinforcement for LC 5:Axial + Mxx + Myy
Middle

Bottom

Madd-x

(kNm) 0.0

Top

0.0

0.0

Madd-y

(kNm) 0.0

0.0

0.0

Mx

(kNm) 148.0

88.8

0.0

My

(kNm) 75.0

45.0

0.0

Mmin

(kNm) 14.8

14.8

0.0

M-design (kNm) 165.9

99.6

0.0

Design axis ()

26.87

26.87

90.00

Safety factor

2.11

2.37

1.01

(mm) 2815

2815

2815

1.41 %

1.41 %

789

789

Asc

Moment distribution along the height of the column for bending about the design axis:
The final design moments were calculated as the vector sum of the X- and Y- moments
of the critical load case. This also determined the design axis direction
At the top, Mx = 165.9 kNm
Near mid-height, Mx = 99.6 kNm
At the bottom, Mx = 0.0 kNm

Percentage
AsNom

1.41 %

(mm) 789

Critical load case: LC 5

Design results for all load cases:


Load case

Axis

N (kN)

Load case 1
Axial

X-X
Y-Y

1480.0

M1 (kNm) M2 (kNm) Mi (kNm) Madd (kNm) Design


0.0
0.0

0.0
0.0

0.0
0.0

0.0
0.0

Top

M (kNm) M' (kNm)


0.0
0.0

14.8

Safety
factor
2.486

Job Number
Job Title
Software Consultants (Pty) Ltd
Internet: http://www.prokon.com
E-Mail : mail@prokon.com

Client
Calcs by

Load case

Axis

N (kN)

Load case 2
Axial + Mecc

X-X
Y-Y

1480.0

0.0
0.0

38.0
19.0

22.8
11.4

0.0
0.0

Load case 3
Axial + Mxx

X-X
Y-Y

1480.0

0.0
0.0

148.0
38.0

88.8
22.8

0.0
0.0

Load case 4
Axial + Myy

X-X
Y-Y

1480.0

0.0
0.0

38.0
19.0

22.8
11.4

0.0
0.0

1480.0

0.0
0.0

148.0
75.0

88.8
45.0

0.0
0.0

Load case 5
X-X
Axial + Mxx + Myy
Y-Y

Sheet

KTP/10/13
NEW FUTURA
M/s KTP CONSULATNTS PTE LTD
Checked by
HT
T&T

M1 (kNm) M2 (kNm) Mi (kNm) Madd (kNm) Design

Load case 5 (Axial + Mxx + Myy) is critical.

Date

M (kNm) M' (kNm)

OCT 2015
Safety
factor

Middle

38.0
19.0

25.5

2.521

Top

148.0
38.0

152.8

2.204

Middle

38.0
19.0

25.5

2.521

Top

148.0
75.0

165.9

2.105