2
Lindapters experienced
Engineers will devise your
bespoke solution
>
3
An Engineer will send
you a design drawing,
as below
GENERAL NOTES:
1.
2.
3.
Top Beam
Flange Width = 203mm
Flange Thickness = 15.5mm
4.
5.
10
DRAWING NOTES:
Lower Beam
Flange Width = 102mm
Flange Thickness = 6mm
1.
2.
3.
4.
DIMENSIONS ARE IN MM
TOLERANCES:
ANGULAR:
BEND
MATERIAL COATINGS TO BE SPECIFIED BY THE ENGINEER
Assembly Data:
Factor of Safety :
23.2 kN
5:1
Factor of Safety :
Static Slip Resistance
1.4 kN
SWL =
5:1
Lindapter Fastener
69 Nm
Tightening Torque =
For combined loadings the current relevant national
standard should be taken into consideration
Static Tensile SWL =
REV.
BY
DATE
DRAWING TITLE
GC001-1
Connection Details
116
218
180
DESCRIPTION
PROJECT
DETAIL A
SCALE 1 : 1.5
270
14 THRU
www.lindapter.com
ENQUIRY N.
CUSTOMER
DRAWN
SCALE:
DWG. NO.
DATE
NOT TO SCALE
CHECKED
WEIGHT:
SWXXXX-XX
REV.
www.Lindapter.com
Lower Beam
Flange Width = 102mm
Flange Thickness = 6m
What we require...
>
Free design
proposal
3D
2D / 3D
drawings
116
180
Free connection design is just a small part of Lindapters service. We offer comprehensive
design and support, tailoring our products to your application:
>
>
Quotation
>
Supply
14 THRU
Installation
guidance
>> For simple Girder Clamp connections try the Assembly Selector today at www.Lindapter.com <<
Tech Support: support@Lindapter.com / General Enquiries: enquiries@Lindapter.com / T: +44 (0) 1274 521444
www.Lindapter.com
Linda
Loca
Linda
DETAIL A
SCALE 1 : 1.5
270
The Service
Linda
M12