Sunteți pe pagina 1din 3

SGC Gas Turbine : MYB01EC001

Start up Program : ( Steps 1 16 )


Step 1 :

Signal definition & checks internally


*
*

Step 2 :

Preparation of auxiliaries
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*

Step 3 :

Anti Condensate Heat Compressor


IGV Controller
FO drain valve 1 & 2
SLC Comp air shut off valve
Hydraulic System
SLC Pressure keeping
SLC Hydraulic heating
SGC Natural Gas
SGC Fuel Oil
SGC Lube Oil
SGC Emulsion
IGV Position controller
SLC Gen.Cooling pumps
SLC Gen.Cooling Fans
LV Change over
O/S Protection System 1,2
SGC HCO
SGC NG drainage

..MBA10AT001
..MBY10DT040
..MBA22AA001,2
..MBL20EE010
..MBX20EE010
..MBX00EE010
..MBX00EE010
..MBP01EC001
..MBN01EC001
..MBV01EC001
..MBU02EC001
..MBA11DE002
..MPR10EE010
..MPR30EE010
..BFE00EE010
..MYB01EZ011/12B
..MBA50EC001
..MBP40EC001

Off
On
Close
Open
On
On
Select
Select
On
Select
On
On
On
Check
Check
On
Check

..MKC01DE102
..MKY01DE011
..MKY01DE012
..MKY01DE013
..MBJ01DE100Q
..MKA11EE001
..MKC05EE001

Auto
Sele CMD 1
Sele CMD 1
Sele CMD 1
Preparation
On
On

..MBA41AA051
..MBA42AA051
..MBA43AA051
..MBA44AA051

Open
Open
Open
Open

Electrical Check up
*
*
*
*
*
*
*

Step 4 :

SFC start operation Normal ( ..MBJ01DE100Q )


Followed by other feedback from step 2 10 ( L001 )
L005 : . Checks for SGC GT for RELS MIS

Voltage Controller
Unit CB Selection
GCB Selection
Unit Aux CB Selection
SFC Start Operation
SLC Generator Space Heater
SLC Exciter Space Heater

Compressor Preparation
*
*
*
*

Compressor
Compressor
Compressor
Compressor

Blow
Blow
Blow
Blow

off
off
off
off

1.1
1.2
2
3

SGC Gas Turbine : MYB01EC001


Step 5 :

HRSG Purge Sequence


*

Step 6 :

Receiving FB for normal start mode operation ..MBJ01DE100Q ZV01

SFC

..MBJ01DE102

On

Preparation of Fuel Systems for start up program


*
*

Step 9 :

On ( start )

Preparation of SFC for start up ( Speed < 5.05 rps )


*

Step 8 :

..MBJ01EC001

Selection of Normal .. Start mode


*

Step 7 :

SGC SFC HRSG Purge

SGC Fuel Gas


SGC Fuel Oil

..MBP01EC001
..MBN01EC001

Start, if sele
Start, if sele

Monitoring Speed rise ( 240 seconds )


*

Monitors turbine speed & opens CB of SFC & proceeds to next step.

If ts > 38.6 rps

*
*

SFC Ext isolator


SFC CB

..MBJ01GS091M
..MBJ01DE103M

Open
Off

Step 10 : Monitoring Turbine Speed ( ts ) rise


*

If ts > 49.0 rps, then proceeds to next step.

Step 11 : Reserved
*****

Preparation for Synchronisation

*****

Step 12 : Excitation Preparation


*

Exciter

..MKY01DE012

On

..MKY01DE012

On

..MKY01DE010
..BAC01GS001

On
Close

Step 13 : Selection of GCB for Synchronisation


*

GCB Selection Mode

Step 14 : Synchronisation
*
*

Auto Paralleling device


GCB

Step 15 : Reserved
Step 16 : Steady State Operation

SGC Gas Turbine : MYB01EC001


Shut down Program : ( Steps 51 63 )
Step 51 : Unloading of GT : Checks for load & if < 11.0 MWh,
* GT unload
..MBY10EU001

On

Step 52 : Reserved
Step 53 : Gas turbine unloading
*
*

..MBY10EU001

VAR = Zero balance


..MKC01DE111
Checks for load < 2.0 MWh until reached, then proceeds to next step.

Step 54 : Opening of GCB


*
*
Step 55 : *

Auto Paralleling device


GCB

..MKY01DE010
..BAC01GS001

Off
Open

Exciter

..MKC01DE101

Off

SGC Natural Gas


SGC Fuel Oil
Unit CB Selection
GCB Selection
Unit Aux CB Selection

..MBP01EC001
..MBN01EC001
..MKY01DE011
..MKY01DE012
..MKY01DE013

Shut down
Shut down
Sele CMD 1
Sele CMD 1
Sele CMD 1

F.O drain valve 2


Checks for ts > IGN ( 5.5 rps )

..MBA22AA002

Close

..MBL20AA001

Close

..MBV01EC001

Shut down

Step 56 : Shut down of fuel systems


*
*
*
*
*
Step 57 : *
*

Step 58 : Reserved
Step 59 : *

Checks for ts < 3 rps

Step 60 : *

Compressor air shut off

Step 61 : SGC Lube Oil


Step 62 : Reserved
Step 63 : Reserved

S-ar putea să vă placă și