Measuring & Protective Current Transformer

Manufactured To: IEC 185 & BS 7626

CURRENT TRANSFORMER

PERFORMANCE

The M&P series are complied with BS 7626 and IEC 185
The technical characteristic as follows :
Primary current : 60A to 6000A
Secondary current : 5A or 1A
Maximun voltage : 0.66 kV
Test voltage : 3 kV/min
Frequency : 50 ~ 60 Hz
Burden : 5VA to 30VA
Class :
Measuring CTs : 0.5, 1, 3
Protection CTs : 5P, 10P
Short time thermal current : Ith = 60In
Dynamic rated current : Idyn = 2.5Ith
Standard accuracy limit factor : 5, 10, 15
Operating temperature : - 50C to 400C

Epoxy Resin Coating Current Transformer


DIMENSIONS(mm)
MEASURING TYPE

RATIO

PROTECTION TYPE

ID

OD

HT

60/5A

35

85

100/5A

35

150/5A

ID

OD

HT

5P5

5P10

5P5

5P10

5P5

5P10

50

75

30

38

38

120

120

115

130

35

70

30

38

38

110

110

95

105

200/5A

35

65

30

38

38

100

100

90

105

250/5A

35

65

30

38

38

95

95

90

105

300/5A

50

80

30

48

48

110

110

80

100

400/5A

52

80

25

52

52

105

105

70

85

500/5A

52

80

25

52

52

95

95

62

78

600/5A

65

90

25

65

65

115

115

60

65

800/5A

80

105

25

80

80

120

120

50

65

1000/5A

85

110

25

85

85

125

125

45

55

1200/5A

85

110

25

85

85

125

125

45

55

1600/5A

85

110

25

85

85

125

125

40

45

2000/5A

120

150

25

120

120

150

150

35

43

2500/5A

120

150

25

120

120

150

150

30

40

3000/5A

120

160

30

120

130

165

165

30

35

4000/5A

130

160

30

130

130

168

168

30

35

5000/5A

130

170

30

130

130

168

168

30

35

6000/5A

165

180

30

165

165

190

190

30

35

Measuring & Protective Current Transformer


Manufactured To: IEC 185 & BS 7626

EPOXY RESIN COATING CURRENT


TRANSFORMER
Measurement & Protection Type
Insulation Class "B"
Special core size, terminal arrangements
and output leads

EPOXY RESIN COATING CURRENT


TRANSFORMER SQUARE TYPE
Measurement & Protection Type
Insulation Class "B"
Special core size, terminal arrangements and
output leads

EPOXY RESIN COATING CURRENT


TRANSFORMER SQUARE TYPE
Measurement Class 0.5, 1 & 3 available
Compacted and easily mounted
Transparent terminal covers are supplied and
6.3mm push on tags for connection of shorting link.
Insulation Class "B"
Flame temperature range -30oC to 85oC case
insulation withstand 125oC for 1 hour and 140oC
for 10 minutes.
Enclosure - IP54

CURRENT TRANSFORMER

PERFORMANCE
The M&P series are complied with BS 7626 and IEC 185
The technical characteristic as follows :
Primary current : 400A to 6000A
Secondary current : 5A or 1A
Maximun voltage : 0.66 kV
Test voltage : 3 kV/min
Frequency : 50 ~ 60 Hz
Burden : 5VA to 30VA

Class :

Measuring CTs : 0.5, 1, 3


Protection CTs : 5P, 10P

Short time thermal current : Ith = 60In


Dynamic rated current : Idyn = 2.5Ith
Standard accuracy limit factor : 5, 10, 15
Operating temperature : - 50C to 400C

Epoxy Resin Coating


Current Transformer square type

Burden (VA)
Ratio

MEASURING TYPE

PROTECTION TYPE
5P5

5P10

BUSBAR HOLE DIMENSIONS(mm)

400/5A

15

15

20

10 X 30 mm

500/5A

15

15

20

10 X 30 mm

600/5A

15

15

20

10 x 40 mm

800/5A

15

15

20

10 x 50 mm

1000/5A

15

15

20

10 x 60 mm

1200/5A

15

15

20

10 x 80 mm

1500/5A

15

15

20

10 x 80 x 2 mm

1600/5A

15

15

20

10 x 80 x 2 mm

2000/5A

15

15

20

10 x 80 x 2 mm

2500/5A

15

15

20

10 x 100 x 2 mm

3000/5A

15

15

20

10 x 120 x 2 mm

4000/5A

15

15

20

10 x 150 x2 mm

5000/5A

15

15

20

10 x 150 x 3 mm

6000/5A

15

15

20

10 x 150 x 4 mm

THANH MY ELECTRIC ENGINEERING Co., Ltd


ADDRESS: 98, Ky Con Street, Nguyen Thai Binh Ward, 1st District
TEL: 848 8231832 FAX: 848 8217005
EMAIL: thamy-electric@viettel.vn