Output Wiring
10
12
14
14
15
16
16
Configuration File
17
20
Specifications
21
Additional Resources
23
WARNING
IMPORTANT
ATTENTION
SHOCK HAZARD
Labels may be located on or inside the equipment, for example, a drive or motor, to
alert people that dangerous voltage may be present.
BURN HAZARD
Labels may be located on or inside the equipment, for example, a drive or motor, to
alert people that surfaces may be at dangerous temperatures.
Remove Power
ATTENTION
Remove power before removing or inserting this module. When you remove or
insert a module with power applied, an electrical arc may occur. An electrical
arc can cause personal injury or property damage by:
sending an erroneous signal to your systems field devices, causing
unintended machine motion.
causing an explosion in a hazardous environment.
Electrical arcing causes excessive wear to contacts on both the module and its
mating connector. Worn contacts may create electrical resistance.
Explosion Hazard
Substitution of components may impair suitability for
Class I, Division 2.
Do not replace components or disconnect equipment unless power is switched
off or the area is known to be nonhazardous.
Do not connect or disconnect components unless power is switched off or the
area is known to be nonhazardous.
This product must be installed in an enclosure.
All wiring must comply with N.E.C. article 501-4(b).
Environnements dangereux
Cet quipement est conu pour tre utilis dans des environnements de Classe 1,
Division 2, Groupes A, B, C, D ou non dangereux. La mise en garde suivante
sapplique une utilisation dans des environnements dangereux.
AVERTISSEMENT
Danger Dexplosion
La substitution de composants peut rendre cet quipement impropre une
utilisation en environnement de Classe 1, Division 2.
Ne pas remplacer de composants ou dconnecter l'quipement sans s'tre
assur que l'alimentation est coupe et que l'environnement est class non
dangereux.
Ne pas connecter ou dconnecter des composants sans s'tre assur que
l'alimentation est coupe ou que l'environnement est class non dangereux.
Ce produit doit tre install dans une armoire.
Module Description
1
2a
Labels
Item Description
3
+VDC1
+VDC1
OUT 0
OUT 1
OUT 2
OUT 3
OUT 4
OUT 5
OUT 6
OUT 7
OUT 8
OUT 9
OUT 10
OUT 11
OUT 12
OUT 13
OUT 14
OUT 15
10
+VDC2
+VDC2
OUT 16
OUT 17
OUT 18
OUT 19
OUT 20
OUT 21
OUT 22
OUT 23
OUT 24
OUT 25
OUT 26
OUT 27
OUT 28
OUT 29
OUT 30
OUT 31
DC COM 1 DC COM 2
DC COM 1 DC COM 2
2a
2b
5a
5b
Nameplate label
7a
Upper
tongue-and-groove slots
7b
Lower
tongue-and-groove slots
8a
8b
10
MIL-C-83503 connector
1769-OB32T
8a
7a
7a
2b
5a
5b
7b
7b
8b
31563A-M
(1)
Pollution Degree 2 is an environment where, normally, only non-conductive pollution occurs except that occasionally a
temporary conductivity caused by condensation is expected.
(2)
Over Voltage Category II is the load level section of the electrical distribution system. At this level, transient voltages are
controlled and do not exceed the impulse voltage capability of the products insulation.
(3)
Pollution Degree 2 and Over Voltage Category II are International Electrotechnical Commission (IEC) designations.
3
4
1
6
30536-M
The following procedure shows you how to assemble the Compact I/O system.
1. Disconnect power.
2. Check that the bus lever of the module to be installed is in the unlocked
(fully-right) position.
3. Use the upper and lower tongue-and-groove slots (1) to secure the modules
together (or to a controller).
4. Move the module back along the tongue-and-groove slots until the bus
connectors (2) line up with each other.
5. Use your fingers or a small screwdriver to push the bus lever back slightly to
clear the positioning tab (3).
6. To allow communication between the controller and module, move the bus
lever fully to the left (4) until it clicks, making sure it is locked firmly in
place.
ATTENTION
When attaching I/O modules, it is very important that the bus connectors are
securely locked together to be sure of proper electrical connection.
7. Attach an end-cap terminator (5) to the last module in the system by using
the tongue-and-groove slots as before.
8. Lock the end-cap bus terminator (6).
IMPORTANT
You must use a 1769-ECR or 1769-ECL right or left end cap to terminate the end
of the serial communication bus.
It may be necessary to rock the module slightly from front to back to remove it,
or, in a panel-mounted system, to loosen the screws of adjacent modules
Publication 1769-IN080A-EN-P - August 2006
6. Be sure that the bus lever on the module and on the right-side adjacent
module are in the unlocked (fully-right) position before installing the
replacement module.
7. Slide the replacement module into the open slot.
8. Connect the modules by locking (fully-left) the bus levers on the
replacement module and the right-side adjacent module.
9. Replace the mounting screws (or snap the module onto the DIN rail).
During panel or DIN rail mounting of all devices, be sure that all debris,
including metal chips or wire strands, is kept from falling into the module.
Debris that falls into the module could cause damage when cycling power.
Minimum Spacing
Maintain spacing from enclosure
walls, wireways, or adjacent
equipment. Allow 50 mm (2 in.) of
space on all sides for adequate
ventilation, as shown.
Bottom
End Cap
Compact I/O
Compact I/O
Compact I/O
Compact I/O
Controller
Side
Compact I/O
Top
Side
Host Controller
10
If mounting more modules, mount only the last one of this group and put the
others aside. This reduces the remounting time during drilling and tapping of
the next group.
Output Wiring
ATTENTION
11
+VDC 2
+VDC 1
+VDC 2
24V dc
24V dc
User Side
VDC
S
TR1
VCC
ASIC
OUT
COM
(1)
Recommended Surge Suppression. Use a 1N4004 diode reverse-wired across the load for transistor outputs switching 24V
dc inductive loads. For additional details, refer to Industrial Automation Wiring and Grounding Guidelines, Allen-Bradley
publication 1770-4.1.
(2)
Sourcing Output. Source describes the current flow between the I/O module and the field device. Sourcing output circuits
source current to sinking field devices. Field devices connected to the negative side (DC Common) of the field power supply
are sinking field devices. Europe: dc sinking input and sourcing output module circuits are the commonly used options.
12
Keyed Male
MIL-C-83503
Header
Panel Lights,
Buttons, Sensor
(1)
Maximum cable length is dependent on how much voltage drop (current x (ohms/ft.) x (feet)) your system can tolerate. Your
system should take into account the minimum turn-on voltage required by external loads connected to the 32-point output
module, the minimum turn-on voltage required by the 32-point input module, and all of the voltage drops associated with
wiring to and from the load, sensors, terminal blocks, power sources and the module itself.
13
1492-CABLExx (2)(3)
Connects 32-point Module
to DIN-rail Mountable
Terminal Block
Male
MIL-C-83503
Header
31562-M
Allen-Bradley 1492 wiring systems are available for connecting 32-point I/O
modules to external I/O. These wiring systems include a pre-wired cable available
in four lengths: 0.5 m (1.6 ft), 1.0 m (3.3 ft), 2.5 m (8.2 ft), 5.0 m (16.4 ft). An
interface module for connecting external devices is also available. Cables are
equipped with keyed connectors at both ends for proper connections. Interface
modules are DIN-rail mountable and available with or without field-side status
indicating LED indicators. Stick-on labels are provided with the interface modules
to identify I/O-wiring termination points.
(1)
To maintain group isolation provided by 32-point I/O modules, use a 1492 terminal block that provides group isolation.
Consult 1492 documentation or your Allen-Bradley Sales Office for additional information.
(2)
Maximum cable length is dependent on how much voltage drop (current x (ohms/ft) x (ft)) your system can tolerate. Your
system should take into account the minimum turn-on voltage required by external loads connected to the 32-point output
module, the minimum turn-on voltage required by the 32-point input module, and all of the voltage drops associated with
wiring to and from the load, sensors, terminal blocks, power sources and the module itself. See the table on page 13 for
voltage drop values for the 1492 cables shown above.
(3)
When using 1492-CABLExx, you wont be able to close the I/O module door. Leave it open or detach the removable door.
Voltage Drop
Cat. No.
Voltage Drop at 30 C
Voltage Drop at 60 C
Series C cables
V dc/dc com
Output channel
wires(1)
wires(2)
Output channel
wires
1492-CABLE005H
127 mV
34 mV
144 mV
38 mV
1492-CABLE010H
173 mV
45 mV
196 mV
51 mV
1492-CABLE025H
334 mV
83 mV
388 mV
95 mV
1492-CABLE050H
574 mV
147 mV
686 mV
169 mV
(1)
(2)
14
+V1
+V1
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
CM1
CM1
+V2
+V2
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
CM2
CM2
15
The 1492 interface module stick-on labels are abbreviated as follows: +V1 = V dc 1,
+V2 = V dc 2, CM1 = Com 1, and so on.
If you decide to build your cable using another 1746-N3 to terminate the
cable at the 1492 interface-module end, wire it in the following manner:
Pin 1 to Pin 1, Pin 2 to Pin 2, Pin 3 to Pin 3, and so on.
TIP
If the 1769-OB32T stick-on label set is not available, use the 1492 interface module
stick-on label set for 1746-OB32 modules.
16
4 mm
(5/32 in)
Tang
4 mm
(5/32 in)
Wire
Stop
(2)
(1)
(3)
(4)
Bit Position
15
14
13
12
11
10
w = write
17
Bit Position
15
14
13
12
11
10
r = read
The output modules input data file reflects the output data echo of the
module, not necessarily the electrical state of the output terminals. It does not
reflect shorted or open outputs.
IMPORTANT
It is important to use this input word if the controller adapter supports the
Program mode or Fault mode function, and if it is configured to use them.
Configuration File
The read/writable configuration data file allows the setup of the hold last state and
user-defined safe-state conditions.
Manipulate these bits with programming software, such as, RSLogix 500 or
RSNetWorx for DeviceNet, during initial configuration of the system. In that case,
graphical screens are provided via the programmer to simplify configuration.
However, some systems, such as, 1769-ADN DeviceNet Adapter, also allow the bits
to be altered as part of the control program using communication rungs. In that
case, it is necessary to understand the bit arrangement.
Configuration File
Word
Bit Position
15
14
13
12
11
10
PFE
18
Word
Configuration File
Bit Position
15
14
13
12
11
10
10
11
12
13
14
15
Condition
Bit Setting
Value
Bit Setting
Off
On
Condition
Bit Setting
Value
Bit Setting
Off
On
19
Value Applied
Bit Setting
Program
Fault
Program Conditions
Word or Bit Affected
Condition Applied
Word 0, Bit 0
Program-to-fault Enable
Program value
Word 1
Program state
Word 2
Program value
Off
Word 3
Fault state
Word 4
Fault value
Off
20
ATTENTION
The Transient Pulse Duration as a Function of Load Current graph illustrates that
the duration of the transient is inversely proportional to the load current. Therefore,
as the on-state load current increases, the transient pulse decreases. Power-up
transients do not exceed the time duration shown below, for the amount of loading
indicated, at 60 C (140 F).
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0.0
1
100
200 300
400
500 600
700
21
Specifications
Compact 32-point Solid-state 24V dc Source Output Module - 1769-OB32T
Attribute
Value
Voltage Category
24V dc
10.226.4V dc (source)(3)
Number of Outputs
32
220 mA @ 5V dc (1.10 W)
Heat Dissipation
4.76 Total W (The W per point, plus the min W, with all points
energized.)
Turn-on = 0.5 ms
Turn-off = 4.0 ms
0.1 mA @ 26.4V dc
1.0 mA
0.3V dc @ 0.5 A
0.5 A
2.0 A
4.0 A
8 (The module may not be more than 8 modules away from the power
supply.)
Isolated Groups
Product Code
79
22
(1)
Typical Loading Resistor - To limit the effects of leakage current through solid state outputs, a loading resistor can be
connected in parallel with your load. Use a 56 k ohm, 1/4 W resistor for this modules outputs, 24V dc operation.
(2)
Recommended Surge Suppression - Use a 1N4004 diode reverse-wired across the load for transistor outputs switching 24V
dc inductive loads. For additional details, refer to Industrial Automation Wiring and Grounding Guidelines, Allen-Bradley
publication 1770-4.1.
(3)
Sourcing output - source describes the current flow between the I/O module and the field device. Sourcing output circuits
source current to sinking field devices. Field devices connected to the negative side (DC Common) of the field power supply
are sinking field devices. Europe: dc sinking input and sourcing output module circuits are the commonly used options.
Environmental Specifications
Attribute
Value
Storage temperature
-4085 C (-40185F)
Operating temperature
060 C (32140 F)
Operating humidity
595% noncondensing
Operating altitude
Vibration, operating
Shock, operating
Shock, nonoperating
EN50081-2 Class A
Electrical /EMC
2 kV, 5 kHz
Conducted immunity
(IEC61000-4-6)
(1)
Conducted Immunity frequency range may be 150 kHz30 MHz if the radiated immunity frequency range is 301000 MHz.
Certifications
Certification
Value
Agency certification(1)
(1)
See the Product Certification link at http://www.ab.com for Declarations of Conformity, certificates, and other certification
details.
23
Additional Resources
You can view or download publications at
http://literature.rockwellautomation.com. To order paper copies of technical
documentation, contact your local Rockwell Automation distributor or sales
representative.
Related Documentation
For
Pub. No.
1764-RM001
1769-UM001
1769-UM007
1770-4.1
Installation Assistance
If you experience a problem with a hardware module within the first 24 hours of installation,
please review the information that's contained in this manual. You can also contact a special
Customer Support number for initial help in getting your module up and running:
United States
Please contact your local Rockwell Automation representative for any technical
support issues.
Contact your distributor. You must provide a Customer Support case number (see
phone number above to obtain one) to your distributor in order to complete the return
process.
Please contact your local Rockwell Automation representative for return procedure.
Compact I/O, MicroLogix, CompactLogix, RSLogix 500, RSNetWorx for DeviceNet, Allen-Bradley, and Rockwell Automation
are trademarks of Rockwell Automation, Inc.
Trademarks not belonging to Rockwell Automation are property of their respective companies.
PN 40071-219-01(1)
Copyright 2006 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.