Construction
Pressure range
Output signal
0 20 mA, 4 20 mA,
0 5 V DC, 0 10 V DC
Medium temperature
40 200C
Electrical connection
Plug or cable
Pressure connection
Type of protection
IP 65, IP 67
EMC
Accessories
Test certificate
GUEMISA
Selection Chart
Ordering example:
System design
ED 513
4 .
EDX 513
EDX 513
EEx ia II C (ATEX) 3)
Pressure type
Gauge pressure
3
Absolute pressure
4
Static error band 0,4% FS (Tmed = 25C), comp. temp. range 0 50C 1
(Tamb = 25C)
0,2% FS (Tmed = 25C), comp. temp. range 0 50C 2
0,4% FS by adjusted temperature1)
7
8
0,2% FS by adjusted temperature1)
Electrical connect. Cable 2 m
IP 65
1
Plug Fischer 2)
IP 67
2
Plug DIN 41 524 (Binder)
IP 65
3
Plug DIN 43 650
IP 65
4
Output signal
IA = 0 20 mA
1
IA = 4 20 mA
2
UA = 0 10 V DC
4
UA = 0 5 V DC
5
Pressure connect. Male thread G12 DIN 3852, stainless steel 1.4435
Diaphragm
Stainless steel 1,4404/316 L
Hastelloy C-276
Pressure range
Also other pressure ranges and versions in Pa, psi, H2O etc. available
155
Ordercode
1
1
2
Pressure
range
126
136
A56
mbar
0 100
0 160
0 200
146
156
A66
166
0 250
0 400
0 500
0 600
025
035
A15
bar
0 1
0 1,6
0 2
045
055
A25
065
0
0
0
0
075
085
A35
0 10
0 16
0 20
095
105
A45
0 25
0 40
0 50
115
125
135
0 60
0 100
0 160
A55
145
155
0 200
0 250
0 400
2,5
4
5
6
Ordercode
Pressure
range
D06
D26
D56
mbar
-100 -100
-100 -200
-100 -500
H66
H76
H86
-100 -100
-200 -200
-500 -500
D85
H05
525
bar
-0 -1
-1 -1
-1 -3
535
545
-1 -5
-1 -9
1)
Adjusted temperature
If the adjustment of the medium is above 25C, the temperature must be advised with the order code /9007/XXXX.
Ordering example: adjustment at 150C, order code /9007/0150.
The compensated temperature range is 25C of the adjusted temperature. If the adjusted temperature is above 175C, the compensated range will always be 150C to 200C.
2)
Cable socket connector included.
3) Version 4 ... 20 mA only
IA = 0 20 mA, UA = 0 5 V, UA = 0 10 V
D6.153 E / 1.01
S._21-24_Kat.Elekt.E
17.01.2001
14:11 Uhr
Seite 22
0 +P
bar
0,1
Maximum Pressure
P max.
bar
Pressure range 2
P 0/P 0 +P
bar
Maximum Pressure
P max.
bar
00,1 00,2
4
10
24
510
1625
15
30
75
100
10
250
600
13
15
19
15
30
30
10
% FS
% FS
% FS
pressure range 1
% FS/10 K
1,8
1,0
0,3
0,3
0,3
0,25
0,25
0,25
0,25
0,25
0,25
pressure range 2
% FS/10 K
1,8
1,0
1,0
0,3
0,3
1,0
0,8
0,5
0,3
0,3
0,3
% FS/10 K
TC zero point1)
TC sensitivity1)
0,25
Housing temperature
20 80
Storage temperature
40 80
IA = 0 20 mA
V DC
16 30
IA = 4 20 mA
V DC
10 30
UA = 0 5 V DC
V DC
09 30
UA = 0 10 V DC
V DC
14 30
Supply voltage U B
yes
yes
Overvoltage protection
Load (R L + R Line)
yes
Ohm
500
IA = 4 20 mA
Ohm
UA = 0 5 V DC
kOhm
UA = 0 10 V DC
kOhm
10
1,2
IA = 0 20 mA
% FS
MOhm
fulfilled
fulfilled
level 3 (8 kV)
fulfilled
fulfilled
level 4 (4 kV)
fulfilled
fulfilled
kg
0,35
Weight
1)
Dimensions
Ambient Temperature
Medium pressure
Joint
pabs
p rel
1 bar
0 bar
prohibited
0,5 bar
zone
0,5 bar
p (bar)
L (mm)
0.1 ... 10
171
179
1 mbar
0
50
1 bar
0
100
200
Medium
temperature C
D6.153 E / 1.01