Sunteți pe pagina 1din 18

PRODUCT GUIDE

LFII Residential Sprinklers


Sprinkler System Components
CPVC Pipe & Fittings

Rapid Response Residential Fire Sprinkler Systems


D
evelopedspecificallyforresidential
occupancies
T
hemostcompletesystemonthemarket
todayfromasinglemanufacturer
F
eaturesBlazeMaster CPVCpipeandfittings,
makinginstallationquick,easy,flexible,and
affordable
E
xclusiveten-yearlimitedwarrantyletsyou
installwithconfidence
ProductlinemeetsallNFPAstandards
C
omponentsareallULlistedforresidential
installations

Table of Contents
Series LFII Sprinklers ..............................................................................4-8
Series LFII Dry Sprinklers...........................................................................9
Series LFII NFPA 13
Optimized Sprinklers ......................................................................... 10-13
System Components .........................................................................14-15
CPVC Pipe and Fittings .....................................................................16-17

SeriesLFIISprinklers
LFII (TY2234)

Pendent, Recessed Pendent and Domed Concealed

Fast response
Approved for special
applications with
beamed ceilings
Used in wet pipe
residential sprinkler
systems for one- and
two-family dwellings and
mobile homes per
NFPA 13D
Used in wet pipe
residential occupancies
up to and including four
stories in height per
NFPA 13R
Used in wet pipe
sprinkler systems for the
residential portions of any
occupancy per NFPA 13

LFII (TY1234)

K Factor

K=4.9 (70,6)

Thread Size

1/2 (15 mm)

Escutcheon

Style 20

Bulb Type

3 mm

Finish

White, Chrome, Brass, Custom

Tech Data

TFP400 (TFP450 Domed Concealed)

MAXIMUM
COVERAGE AREA

MAXIMUM
SPACING

MINIMUM FLOW &


RESIDUAL PRESSURE
For Horizontal Ceiling
(Max. 2 rise for 12 run)

ft x ft (m x m)

ft (m)

12 x 12
(3,7 x 3,7)

12
(3,7)

13 GPM (49,2 LPM)


7.0 psi (0,48 bar)

14 x 14
(4,3 x 4,3)

14
(4,3)

13 GPM (49,2 LPM)


7.0 psi (0,48 bar)

16 x 16
(4,9 x 4,9)

16
(4,9)

13 GPM (49,2 LPM)


7.0 psi (0,48 bar)

18 x 18
(5,5 x 5,5)

18
(5,5)

17 GPM (64,3 LPM)


12.0 psi (0,83 bar)

20 x 20
(6,1 x 6,1)

20
(6,1)

20 GPM (75,7 LPM)


16.7 psi (1,15 bar)

155F/68C or 175F/79C

Pendent and Recessed Pendent

Fast response
Used in wet pipe residential
sprinkler systems for oneand two-family dwellings and
mobile homes per NFPA 13D
Used in wet pipe sprinkler
systems for residential
occupancies up to and
including four stories in
height per NFPA 13R

K Factor

K=3.0 (43,2)

Thread Size

1/2 (15 mm)

Bulb Type

3 mm

Finish

White, Chrome, Brass

Tech Data

TFP402

MAXIMUM
COVERAGE AREA

MAXIMUM
SPACING

ft x ft (m x m)

ft (m)

MINIMUM FLOW &


RESIDUAL PRESSURE
For Horizontal Ceiling
(Max. 2 rise for 12 run)
155F/68C or 175F/79C

12 x 12
(3,7 x 3,7)

12
(3,7)

8 GPM (30,3 LPM)


7.1 psi (0,49 bar)

14 x 14
(4,3 x 4,3)

14
(4,3)

11 GPM (41,6 LPM)


13.4 psi (0,92 bar)

16 x 16
(4,9 x 4,9)

16
(4,9)

13 GPM (49,2 LPM)


18.8 psi (1,29 bar)

We can match any Sherwin


Williams color for Flat Plate
and Domed Concealed
sprinklers you install. See the
cover plate chart on page 7 for
standard colors and finishes.

Always refer to the technical data sheet for


complete description and all listing criteria, design
parameters, installation instructions, care and
maintenance guidelines and our limited warranty.

LFII (TY1334)

Horizontal and Recessed Horizontal Sidewall

Fast response
Used in wet pipe residential sprinkler
systems for one- and two-family dwellings
and mobile homes per NFPA 13D
Used in wet pipe residential occupancies
up to and including four stories in height per
NFPA 13R
Used in wet pipe sprinkler systems for the
residential portions of any occupancy
per NFPA 13

K Factor

K=4.2 (60,5)

Thread Size

1/2 (15 mm)

Escutcheon

Style 20

Bulb Type

3 mm

Finish

White, Chrome, Brass

Tech Data

TFP410

MAXIMUM
COVERAGE AREA
ft x ft (m x m)

MAXIMUM
SPACING
ft (m)

155F/68C

175F/79C

155F/68C

175F/79C

12 x 12
(3,7 x 3,7)

12
(3,7)

12 GPM (45,4 LPM)


8.2 psi (0,57 bar)

12 GPM (45,4 LPM)


8.2 psi (0,57 bar)

13 GPM (49,2 LPM)


9.6 psi (0,48 bar)

13 GPM (49,2 LPM)


9.6 psi (0,48 bar)

14 x 14
(4,3 x 4,3)

14
(4,3)

14 GPM (53,0 LPM)


11.1 psi (0,77 bar)

16 GPM (60,6 LPM)


14.5 psi (1,00 bar)

17 GPM (64, 3 LPM)


16.4 psi (1,13 bar)

18 GPM (68,1 LPM)


18.4 psi (1,27 bar)

16 x 16
(4,9 x 4,9)

16
(4,9)

16 GPM (60,6 LPM)


14.5 psi (1,00 bar)

16 GPM (60,6 LPM)


14.5 psi (1,00 bar)

18 GPM (68,1 LPM)


18.4 psi (1,27 bar)

18 GPM (68,1 LPM)


18.4 psi (1,27 bar)

16 x 18
(4,9 x 5,5)

16
(4,9)

19 GPM (71,9 LPM)


20.5 psi (1,41 bar)

19 GPM (71,9 LPM)


20.5 psi (1,41 bar)

21 GPM (79,5 LPM)


25.0 psi (1,72 bar)

21 GPM (79,5 LPM)


25.0 psi (1,72 bar)

16 x 20
(4,9 x 6,1)

16
(4,9)

23 GPM (87,1 LPM)


30.0 psi (2,07 bar)

19 GPM (71,9 LPM)


20.5 psi (1,41 bar)

26 GPM (98,4 LPM)


38.3 psi (2,64 bar)

26 GPM (98,4 LPM)


38.3 psi (2,64 bar)

LFII (TY2334)

MINIMUM FLOW & RESIDUAL PRESSURE


4 6 (100 mm 150 mm) below ceiling

6 12 (150 mm 300 mm) below ceiling

Horizontal and Recessed Horizontal Sidewall

Fast response
Used in wet pipe residential sprinkler systems for oneand two-family dwellings and mobile homes per NFPA 13D
Used in wet pipe residential occupancies
up to and including four stories in height per
NFPA 13R
Used in wet pipe sprinkler systems for the residential
portions of any occupancy per NFPA 13

K Factor

K=4.4 (63,4)

Thread Size

1/2 (15 mm)

Escutcheon

Style 20

Bulb Type

3 mm

Finish

White, Chrome, Brass

Tech Data

TFP412

MAXIMUM
COVERAGE AREA
ft x ft (m x m)

MAXIMUM
SPACING
ft (m)

155F/68C

175F/79C

155F/68C

175F/79C

12 x 12
(3,7 x 3,7)

12
(3,7)

13 GPM (49,2 LPM)


8.7 psi (0,60 bar)

13 GPM (49,2 LPM)


8.7 psi (0,60 bar)

13 GPM (49,2 LPM)


8.7 psi (0,60 bar)

13 GPM (49,2 LPM)


8.7 psi (0,60 bar)

14 x 14
(4,3 x 4,3)

14
(4,3)

14 GPM (53,0 LPM)


10.1 psi (0,70 bar)

14 GPM (53,0 LPM)


10.1 psi (0,70 bar)

14 GPM (53,0 LPM)


10.1 psi (0,70 bar)

14 GPM (53,0 LPM)


10.1 psi (0,70 bar)

16 x 16
(4,9 x 4,9)

16
(4,9)

16 GPM (60,6 LPM)


13.2 psi (0,91 bar)

16 GPM (60,6 LPM)


13.2 psi (0,91 bar)

17 GPM (64,3 LPM)


14.9 psi (1,03 bar)

17 GPM (64,3 LPM)


14.9 psi (1,03 bar)

16 x 18
(4,9 x 5,5)

16
(4,9)

19 GPM (71,9 LPM)


18.6 psi (1,28 bar)

19 GPM (71,9 LPM)


18.6 psi (1,28 bar)

20 GPM (75.7 LPM)


20.7 psi (1,43 bar)

20 GPM (75.7 LPM)


20.7 psi (1,43 bar)

16 x 20
(4,9 x 6,1)

16
(4,9)

23 GPM (87,1 LPM)


27.3 psi (1,88 bar)

23 GPM (87,1 LPM)


27.3 psi (1,88 bar)

23 GPM (87,1 LPM)


27.3 psi (1,88 bar)

23 GPM (87,1 LPM)


27.3 psi (1,88 bar)

18 x 18
(5,5 x 5,5)

18
(5,5)

23 GPM (87,1 LPM)


27.3 psi (1,88 bar)

23 GPM (87,1 LPM)


27.3 psi (1,88 bar)

23 GPM (87,1 LPM)


27.3 psi (1,88 bar)

23 GPM (87,1 LPM)


27.3 psi (1,88 bar)

18 x 20
(5,5 x 6,1)

18
(5,5)

26 GPM (98,4 LPM)


34.9 psi (2,41 bar)

26 GPM (98,4 LPM)


34.9 psi (2,41 bar)

26 GPM (98,4 LPM)


34.9 psi (2,41 bar)

26 GPM (98,4 LPM)


34.9 psi (2,41 bar)

MINIMUM FLOW & RESIDUAL PRESSURE


4 6 (100 mm 150 mm) below ceiling

6 12 (150 mm 300 mm) top of deflector to ceiling

SeriesLFIISprinklers
LFII (TY3596)

Flat Plate Concealed Pendent

Fast response
Solder type
Can be used for
horizontal and
sloped ceilings

K Factor

K= 4.9 (70,6)

Thread Size

1/2 (15 mm)

Finish

White, Chrome, Brass, Custom

Tech Data

TFP442

Used in wet pipe


residential sprinkler
systems for one- and
two-family dwellings
and mobile homes per
NFPA 13D
Used in wet pipe
residential sprinkler
systems for residential
occupancies up
to and including
four stories in height
per NFPA 13R
Cover plate conceals
sprinkler components
above ceiling

MAXIMUM
COVERAGE AREA

MAXIMUM
SPACING

MINIMUM FLOW &


RESIDUAL PRESSURE
For Horizontal Ceiling
(Max. 2 rise for 12 run)

ft x ft (m x m)

ft (m)

12 x 12
(3,7 x 3,7)

12
(3,7)

13 GPM (49,2 LPM)


7.0 psi (0,48 bar)

14 x 14
(4,3 x 4,3)

14
(4,3)

13 GPM (49,2 LPM)


7.0 psi (0,48 bar)

16 x 16
(4,9 x 4,9)

16
(4,9)

13 GPM (49,2 LPM)


7.0 psi (0,48 bar)

18 x 18
(5,5 x 5,5)

18
(5,5)

17 GPM (64,3 LPM)


12.0 psi (0,83 bar)

20 x 20
(6,1 x 6,1)

20
(6,1)

20 GPM (75,7 LPM)


16.7 psi (1,15 bar)

160F/71C

Flat Plate Concealed Cover Plate Tool

Specially designed for installing and removing


TYCO LFII and RFII Flat plate concealed cover plates
Contains foam insert to prevent scratching of cover plate finish
Attaches to painters pole, or a length of 1 CPVC pipe
No need for ladder or scaffold to install cover plates

Always refer to the technical data sheet for


complete description and all listing criteria, design
parameters, installation instructions, care and
maintenance guidelines and our limited warranty.

Flat Plate Concealed Cover Plate Colors & Finishes

Brushed
Brass

Brushed
Chrome

Jet Black
(RAL 9005)

Light Ivory
(RAL 1015)

Beige
(RAL 1001)

Terra Brown
(RAL 8028)

Grey White
(RAL 9002)

Signal White
(RAL 9003)

Custom Colors
Available

BeforeMakingAFinalColorSelection
The purpose of this color chart is to provide a basic representation of Rapid Response Flat Plate Concealed Cover Plate finish colors.
This color chart shall not be used for final color selection, as color differences may occur in print and on monitors when
compared to the actual product. Actual color selection should be made from a sample supplied by Tyco Fire Protection Products.
Samples shall be prepared using same color applications, tools and techniques to assure consistency and accuracy.
Please contact your Tyco Fire Protection Products representative for more information.

SeriesLFIISprinklers
LFII (TY2284)

Flush Pendent

Fast response
Solder type
Approved for special
applications with
beamed ceilings
Used in wet pipe
residential sprinkler
systems for one- and
two-family dwellings
and mobile homes per
NFPA 13D
Used in wet pipe
residential sprinkler
systems for residential
occupancies up to and
including four stories in
height per NFPA 13R
Used in wet pipe sprinkler
systems for the residential
portions of any occupancy
per NFPA 13

LFII (TY2284)

K Factor

K=4.2 (60,5)

Thread Size

1/2 (15 mm)

Finish

White, Chrome, Brass, Black

Tech Data

TFP420

MAXIMUM
COVERAGE AREA

MAXIMUM
SPACING

ft x ft (m x m)

ft (m)

MINIMUM FLOW &


RESIDUAL PRESSURE
For Horizontal Ceiling
(Max. 2 rise for 12 run)
162F/72C

12 x 12
(3,7 x 3,7)

12
(3,7)

13 GPM (49,2 LPM)


9.6 psi (0,66 bar)

14 x 14
(4,3 x 4,3)

14
(4,3)

13 GPM (49,2 LPM)


9.6 psi (0,66 bar)

16 x 16
(4,9 x 4,9)

16
(4,9)

14 GPM (53,0 LPM)


11.1 psi (0,77 bar)

18 x 18
(5,5 x 5,5)

18
(5,5)

18 GPM (68,1 LPM)


18.4 psi (1,27 bar)

20 x 20
(6,1 x 6,1)

20
(6,1)

22 GPM (83.3 LPM)


27.4 psi (1,89 bar)

Flush Horizontal Sidewall

Fast response
Solder type
Approved for special
applications with
beamed ceilings

K Factor

K= 4.2 (60,5)

Thread Size

1/2 (15 mm)

Finish

White, Chrome, Brass, Custom

Tech Data

TFP425

Used in wet pipe


residential sprinkler
systems for one- and
two-family dwellings
and mobile homes per
NFPA 13D
Used in wet pipe
residential sprinkler
systems for residential
occupancies up to and
including four stories in
height per NFPA 13R
Used in wet pipe sprinkler
systems for the residential
portions of any occupancy
per NFPA 13

MAXIMUM
COVERAGE AREA

MAXIMUM
SPACING

ft x ft (m x m)

ft (m)

MINIMUM FLOW &


RESIDUAL PRESSURE
Top of Deflector to Ceiling
4 to 6 (100 mm 150 mm)
162F/72C

12 x 12
(3,7 x 3,7)

12
(3,7)

13 GPM (49,2 LPM)


9.6 psi (0,66 bar)

14 x 14
(4,3 x 4,3)

14
(4,3)

16 GPM (60,6 LPM)


14.5 psi (1,00 bar)

16 x 16
(4,9 x 4,9)

16
(4,9)

20 GPM (75,7 LPM)


22.7 psi (1,57 bar)

Always refer to the technical data sheet for


complete description and all listing criteria, design
parameters, installation instructions, care and
maintenance guidelines and our limited warranty.

SeriesLFIIDry Sprinklers

LFII (TY2235)ResidentialDrySprinkler,RecessedPendent
Fast response
For residential occupancies per
NFPA 13D, 13R and residential
portions of any occupancy per NFPA 13
UL listed for use in wet pipe, dry pipe
and pre action systems

K Factor

K=4.9 (70,6)

Thread Size

1 NPT (25 mm)

Bulb Type

3 mm

Finish

White, Chrome, Brass

Tech Data

TFP460

MAXIMUM
COVERAGE AREA
ft x ft (m x m)

MAXIMUM
SPACING
ft (m)

DRY PIPE

WET PIPE

12 x 12
(3,7 x 3,7)

12
(3,7)

13 GPM (49,2 LPM)


7.0 psi (0,48 bar)

13 GPM (49,2 LPM)


7.0 psi (0,48 bar)

14 x 14
(4,3 x 4,3)

14
(4,3)

14 GPM (52,9 LPM)


8.2 psi (0,57 bar)

14 GPM (52,9 LPM)


8.2 psi (0,57 bar)

16 x 16
(4,9 x 4,9)

16
(4,9)

15 GPM (56,8 LPM)


9.4 psi (0,65 bar)

15 GPM (56,8 LPM)


9.4 psi (0,65 bar)

16 x 18
(4,9 x 5,5)

16
(4,9)

18 GPM (68,1 LPM)


13.5 psi (0,93 bar)

18 GPM (68,1 LPM)


13.5 psi (0,93 bar)

16 x 20
(4,9 x 6,1)

16
(4,9)

21 GPM (79,5 LPM)


18.3 psi (1,30 bar)

21 GPM (79,5 LPM)


18.4 psi (1,30 bar)

LFII (TY2335)

MINIMUM FLOW & RESIDUAL PRESSURE


For Horizontal Ceilings (Max. 2 rise for 12 run)

Residential Dry Sprinkler, Horizontal Sidewall

Fast response
For residential occupancies per NFPA
13D, 13R and residential portions of any
occupancy per NFPA 13
UL listed for use in wet pipe, dry pipe and
pre action systems

K Factor

K=4.4 (63,4)

Thread Size

1 NPT (25 mm)

Bulb Type

3 mm

Finish

White, Chrome, Brass

Tech Data

TFP461

MAXIMUM
COVERAGE AREA

MAXIMUM
SPACING

MINIMUM FLOW & RESIDUAL PRESSURE


For Horizontal Ceilings (Max. 2 rise for 12 run)

ft x ft (m x m)

ft (m)

DRY PIPE

WET PIPE

DRY PIPE

WET PIPE

12 x 12
(3,7 x 3,7)

12
(3,7)

13 GPM (49,2 LPM)


8.7 psi (0,60 bar)

13 GPM (49,2 LPM)


8.7 psi (0,60 bar)

15 GPM (56,8 LPM)


11.6 psi (0,80 bar)

15 GPM (56,8 LPM)


11.6 psi (0,80 bar)

14 x 14
(4,3 x 4,3)

14
(4,3)

16 GPM (60,6 LPM)


13.2 psi (0,91 bar)

14 GPM (53,0 LPM)


10.1 psi (0,70 bar)

16 GPM (60,6 LPM)


13.2 psi (0,91 bar)

15 GPM (56,8 LPM)


11.6 psi (0,80 bar)

16 x 16
(4,9 x 4,9)

16
(4,9)

17 GPM (64,3 LPM)


14.9 psi (1,03 bar)

17 GPM (64,3 LPM)


14.9 psi (1,03 bar)

19 GPM (71,9 LPM)


18.6 psi (1,28 bar)

19 GPM (71,9 LPM)


18.6 psi (1,28 bar)

16 x 18
(4,9 x 5,5)

16
(4,9)

N/A

19 GPM (71,9 LPM)


18.6 psi (1,28 bar)

N/A

20 GPM (75,7 LPM)


20.7 psi (1,43 bar)

16 x 20
(4,9 x 6,1)

16
(4,9)

N/A

25 GPM (94,6 LPM)


32.3 psi (2,23 bar)

N/A

25 GPM (94,6 LPM)


32.3 psi (2,23 bar)

4 6 (100 mm 150 mm) Top of Deflector to Ceiling

6 12 (150 mm 300 mm) Top of Deflector to Ceiling

NFPA13OptimizedSprinklers
Thelargeorifice6.9K,5.6Kand5.8Ksprinklersareprimarilyintendedforresidentialusewherethereis
a0.1gpm/sq.ft.densityNFPA13designrequirement,andaregenerallyusedforinstallationsinexcess
offourstories.Theyareoptimizedforresidentialapplicationswherethishigherwater-flowdemandis
required,andcanmeetthoserequirementswithlesspressureandsmallerpipesizes.

LFII (TY4234) Pendent,RecessedPendentandDomedConcealed


Fast response

K Factor

K=6.9 (99,4)

Used in wet pipe


residential sprinkler
systems for one- and
two-family dwellings and
mobile homes per
NFPA 13D

Thread Size

3/4 (19.05 mm)

Escutcheon

Style 30

Bulb Type

3 mm

Finish

White, Chrome, Brass, Custom

Tech Data

TFP408

Used in wet pipe


residential occupancies
up to and including four
stories in height
per NFPA 13R
Used in wet pipe
sprinkler systems for
the residential portions
of any occupancy
per NFPA 13

MAXIMUM
COVERAGE AREA
ft x ft (m x m)

MAXIMUM
SPACING
ft (m)

MINIMUM FLOW & RESIDUAL PRESSURE


For Horizontal Ceilings (Max. 2 rise for 12 run)
Pendent and Recessed Pendent
Concealed Pendent
155F/68C or 175F/79C

155F/68C or 175F/79C

12 x 12
(3,7 x 3,7)

12
(3,7)

19 GPM (71,9 LPM)


7.6 psi (0,52 bar)

19 GPM (71,9 LPM)


7.6 psi (0,52 bar)

14 x 14
(4,3 x 4,3)

14
(4,3)

19 GPM (71,9 LPM)


7.6 psi (0,52 bar)

19 GPM (71,9 LPM)


7.6 psi (0,52 bar)

16 x 16
(4,9 x 4,9)

16
(4,9)

19 GPM (71,9 LPM)


7.6 psi (0,52 bar)

19 GPM (71,9 LPM)


7.6 psi (0,52 bar)

18 x 18
(5,5 x 5,5)

18
(5,5)

19 GPM (71,9 LPM)


7.6 psi (0,52 bar)

21 GPM (79,5 LPM)


9.3 psi (0,64 bar)

20 x 20
(6,1 x 6,1)

20
(6,1)

22 GPM (87,1 LPM)


10.2 psi (2,07 bar)

24 GPM (90,8 LPM)


12.1 psi (1,15 bar)

Always refer to the technical data sheet for


complete description and all listing criteria, design
parameters, installation instructions, care and
maintenance guidelines and our limited warranty.

LFII (TY3934)5.8KPendent,RecessedPendent
UL and C-UL Listed

K Factor

K=5.8 (83,5)

Fast response

Thread Size

1/2 (19.05 mm)

Escutcheon

Style 20

Bulb Type

3 mm

Finish

Natural Brass, Pure or Signal White,


Jet Black, Chrome Plated

Tech Data

TFP401

Used in wet pipe


residential sprinkler
systems for one- and
two-family dwellings and
mobile homes per
NFPA 13D
Used in wet pipe
residential occupancies
up to and including four
stories in height
per NFPA 13R
Used in wet pipe
sprinkler systems for
the residential portions
of any occupancy
per NFPA 13

MAXIMUM
COVERAGE AREA
ft x ft (m x m)

MINIMUM
SPACING
ft (m)

MINIMUM FLOW & RESIDUAL PRESSURE


Pendent and Recessed Pendent
155F/68C / 175F (79C)

12 x 12
(3,7 x 3,7)

12
(3,7)

16 GPM (60,6 LPM)


7.6 psi (0,52 bar)

14 x 14
(4,3 x 4,3)

14
(4,3)

16 GPM (60,6 LPM)


7.6 psi (0,52 bar)

16 x 16
(4,9 x 4,9)

16
(4,9)

16 GPM (60,6 LPM)


7.6 psi (0,52 bar)

18 x 18
(5,5 x 5,5)

18
(5,5)

18 GPM (68,1 LPM)


9.6 psi (0,66 bar)

20 x 20
(6,1 x 6,1)

20
(6,1)

20 GPM (75,7 LPM)


11.9 psi (0,82 bar)

NFPA13OptimizedSprinklers
Thelargeorifice6.9K,5.6Kand5.8Ksprinklersareprimarilyintendedforresidentialusewherethereis
a0.1gpm/sq.ft.densityNFPA13designrequirement,andaregenerallyusedforinstallationsinexcess
offourstories.Theyareoptimizedforresidentialapplicationswherethishigherwater-flowdemandis
required,andcanmeetthoserequirementswithlesspressureandsmallerpipesizes.

LFII (TY3334)

Horizontal and Recessed Horizontal Sidewall

Fast response

K Factor

K=5.6 (80,6)

Used in wet pipe


residential sprinkler
systems for one- and
two-family dwellings
and mobile homes
per NFPA 13D

Thread Size

1/2 (15 mm)

Escutcheon

Style 20

Bulb Type

3 mm

Finish

White, Chrome, Brass, Custom

Tech Data

TFP415

Used in wet pipe


residential occupancies
up to and including
four stories in height
per NFPA 13R
Used in wet pipe
sprinkler systems for
the residential portions
of any occupancy
per NFPA 13

MAXIMUM
COVERAGE AREA
ft x ft (m x m)

MAXIMUM
SPACING
ft (m)

MINIMUM FLOW & RESIDUAL PRESSURE


For Horizontal Ceilings (Max. 2 rise for 12 run)
4 to 6 (102 mm152 mm)
6 to 12 (152 mm305 mm)
155F/68C or 175F/79C

155F/68C or 175F/79C

12 x 12
(3,7 x 3,7)

12
(3,7)

17 GPM (64,3 LPM)


9.2 psi (0,63 bar)

20 GPM (75,7 LPM)


12.8 psi (0,88 bar)

14 x 14
(4,3 x 4,3)

14
(4,3)

19 GPM (71,9 LPM)


11.5 psi (0,79 bar)

22 GPM (83,3 LPM)


15.4 psi (1,06 bar)

16 x 14
(4,9 x 4,3)

16
(4,9)

20 GPM (75,7 LPM)


12.8 psi (0,88 bar)

24 GPM (90,8 LPM)


18.4 psi (1,27 bar)

16 x 16
(4,9 x 4,9)

16
(4,9)

24 GPM (90,8 LPM)


18.4 psi (1,27 bar)

28 GPM (106,0 LPM)


25.0 psi (1,72 bar)

16 x 18
(4,9 x 5,5)

16
(4,9)

26 GPM (98,4 LPM)


21.6 psi (1,49 bar)

31 GPM (117,3 LPM)


30.6 psi (2,11 bar)

16 x 20
(4,9 x 6,1)

16
(4,9)

29 GPM (109,8 LPM)


26.8 psi (1,85 bar)

37 GPM (140,0 LPM)


43.7 psi (3,01 bar)

Always refer to the technical data sheet for


complete description and all listing criteria, design
parameters, installation instructions, care and
maintenance guidelines and our limited warranty.

LFII (TY4334)

Horizontal and Recessed Horizontal Sidewall

Fast response

K Factor

K=5.8 (80,6)

Used in wet pipe residential sprinkler systems


for one- and two-family dwellings and mobile
homes per NFPA 13D

Thread Size

1/2 (15 mm)

Bulb Type

3 mm

Finish

White, Chrome, Brass

Tech Data

TFP417

Used in wet pipe residential occupancies up to


and including four stories in height per NFPA 13R
Used in wet pipe sprinkler systems for the
residential portions of any occupancy per NFPA 13
MAXIMUM
COVERAGE AREA
ft x ft (m x m)

MAXIMUM
SPACING
ft (m)

MINIMUM FLOW & RESIDUAL PRESSURE


4 6 (100 mm 150 mm) Top of Deflector to Ceiling
155F/68C

175F/79C

6 12 (152 mm 305 mm) Top of Deflector to Ceiling


155F/68C

175F/79C

Recessed of Non-Recessed
12 x 12
(3,7 x 3,7)

12
(3,7)

19 GPM (71,9 LPM)


10.7 psi (0,74 bar)

19 GPM (71,9 LPM)


10.7 psi (0,74 bar)

19 GPM (71,9 LPM)


10.7 psi (0,74 bar)

19 GPM (71,9 LPM)


10.7 psi (0,74 bar)

14 x 14
(4,3 x 4,3)

14
(4,3)

21 GPM (79,5 LPM)


13.1 psi (0,90 bar)

21 GPM (79,5 LPM)


13.1 psi (0,90 bar)

23 GPM (79,5 LPM)


15.7 psi (1,08 bar)

23 GPM (79,5 LPM)


15.7 psi (1,08 bar)

16 x 14
(4,9 x 4,9)

16
(4,9)

21 GPM (79,5 LPM)


13.1 psi (0,90 bar)

21 GPM (79,5 LPM)


13.1 psi (0,90 bar)

23 GPM (79,5 LPM)


15.7 psi (1,08 bar)

23 GPM (79,5 LPM)


15.7 psi (1,08 bar)

16 x 16
(4,9 x 4,9 )

16
(4,9)

21 GPM (79,5 LPM)


13.1 psi (0,90 bar)

21 GPM (79,5 LPM)


13.1 psi (0,90 bar)

23 GPM (79,5 LPM)


15.7 psi (1,08 bar)

23 GPM (79,5 LPM)


15.7 psi (1,08 bar)

16 x 18
(4,9 x 5,5)

16
(4,9)

23 GPM (79,5 LPM)


15.7 psi (1,08 bar)

23 GPM (79,5 LPM)


15.7 psi (1,08 bar)

24 GPM (90,8 LPM)


17.1 psi (1,18 bar)

24 GPM (90,8 LPM)


17.1 psi (1,18 bar)

16 x 20
(4,9 x 6,7)

16
(4,9)

29 GPM (109,8 LPM)


25.0 psi (1,72 bar)

29 GPM (109,8 LPM)


25.0 psi (1,72 bar)

30 GPM (113,6 LPM)


26.8 psi (1,85 bar)

30 GPM (113,6 LPM)


26.8 psi (1,85 bar)

18 x 18
(5,5 x 5,5)

18
(5,5)

29 GPM (109,8 LPM)


25.0 psi (1,72 bar)

29 GPM (109,8 LPM)


25.0 psi (1,72 bar)

30 GPM (113,6 LPM)


26.8 psi (1,85 bar)

30 GPM (113,6 LPM)


26.8 psi (1,85 bar)

38 GPM (143,8 LPM)


42.9 psi (2,96 bar)

40 GPM (151,4 LPM)


47.6 psi (2,96 bar)

40 GPM (151,4 LPM)


47.6 psi (2,96 bar)

Non-Recessed
16 x 22
(4,9 x 6,7)

16
(4,9)

38 GPM (143,8 LPM)


42.9 psi (2,96 bar)

System Components

ResidentialDomestic
Shut-offValve1and2
Used in piping systems that supply water to
both domestic service and the fire sprinkler
system designed per NFPA 13D or 13R in
one/two- family dwellings and mobile homes
In the set position, water is available on demand
to the domestic system, and the valve acts as a
check valve for the fire protection system
When a sprinkler operates, the supply to the domestic
system is automatically shut off, maximizing
the available water supply for fire protection
Eliminates the need for expensive pumps, pressurized
tanks, or electrically operated domestic shutoff valves

PowerballButterflyValves
Ideal for use in residential sprinkler systems
as main control valves
An alternative to bulky OS&Y valves
Mandated visual indicator showing that the
valve is open or closed
Available from 1 through 2-1/2

Resi-Riser
Compact, pre-assembled, ready to install sprinkler riser
Brass construction for use in potable water supply
Available in 1 - 2 (25 mm - 50 mm) sizes
Integral test and drain assembly, flow switch with
retard mechanism, 300 psi gauge, and check valve
Compact size allows for easy installation between
2 x 4 studs in wall
Molded mounting points allow for fast and easy
left or right-hand installation
Available with or without pressure relief valve
feature and flow switch retard mechanism

RiserManifold
Available in 1 - 2
Available in either threaded or grooved configurations
Meets NFPA 13, 13R and 13D requirements

Always refer to the technical data sheet for


complete description and all listing criteria, design
parameters, installation instructions, care and
maintenance guidelines and our limited warranty.

ModelVS-SP
WaterFlowDetector
Used with wet pipe sprinkler systems in
residential dwellings and mobile homes
Actuation of the switch can initiate an alarm
indicating that the sprinkler system is operating
Sustained flow of 8 gallons per minute will deflect
the vane and actuate a single-pole, double-throw
snap action switch
Can be wired to a local bell and/or protection
panel for outside notification to an alarm
company or fire department

HangersforBlazeMaster
CPVCProducts
Tyco offers a full line of pipe hangers designed
especially for use with BlazeMaster CPVC Products.
Designed for ease of installation
Hangers have rounded edges to prevent
damage to pipe and fittings
Meets the requirements specified in NFPA 13,
NFPA 13R and NFPA 13D

SprinklerHeadCabinet
Spare sprinkler head cabinets are available.
All cabinets have ample room for
sprinkler wrench storage.

ElectricAlarmBell
Ideally suited for residential applications
Unobtrusive to the homeowner, yet absolutely
dependable in a fire event
When used with a flow switch, if water flow
occurs in a sprinkler system protecting residential
occupancies, an audible alarm sounds to
alert the occupants and neighbors of trouble

CPVCInstallationEquipment
Retrofit Tools
Cutting and Deburring Tools
BlazeMaster Caulk & Walk Firestop
One-step CPVC Cement and Daubers
Hangers & Fasteners

CPVCPipe&Fittings

The Rapid Response Residential Fire Sprinkler System


features CPVC Pipe and Fittings manufactured with
Lubrizols BlazeMaster compound listed by
Underwriters Laboratories, Inc. for use in:
Light hazard occupancies as defined in the
Standard for Installation of Fire Sprinkler
Systems, NFPA 13
Residential occupancies as defined in the
Standard for Installation of Fire Sprinkler Systems
in Residential Occupancies up to Four Stories in
Height, NFPA 13R

CPVC COUPLING

CPVC CAP

Residential occupancies as defined in the Standard


for Fire Sprinkler Systems in One- and Two-Family
Dwellings and Manufactured Homes, NFPA 13D
Air plenums, as defined by the Installation
of Air Conditioning and Ventilating Systems,
NFPA 90A and model mechanical codes
Underground water pressure service, NFPA 24
Unfinished basements
(Note: for complete listing and approval information,
please refer to the installation instructions and technical
manual No. 19-1.0.)

CPVC ELBOW 45

CPVC BUSHING

CPVC ELBOW 90

CPVC TEE

CPVC REDUCING
TEE

CPVC PIPE
(3/4 3)

CPVC CROSS

16

CPVC REDUCING
COUPLING

Always refer to the technical data sheet for


complete description and all listing criteria, design
parameters, installation instructions, care and
maintenance guidelines and our limited warranty.

InstallWithConfidence
Tyco BlazeMaster CPVC Piping Systems are UL and
cUL listed, FM approved, and exceed ASTM standards.
Benefits over traditional piping systems include:
Resistant to rust, scale and foreign contaminant
buildup
Superior flow characteristics for increased
hydraulic capabilities (C-Factor=150)

CPVC GROOVED
COUPLING ADAPTER
(GROOVE X SLIP)

Easily transported, handled and modified on site


Can be easily connected to copper and steel piping

BACK-TO-BACK
CROSS SPRINKLER
HEAD ADAPTER

Resist sweating and condensation


Immune to Microbiologically Influenced Corrosion (MIC)

FirePerformance
CPVC has an LOI (Limited Oxygen Index) that is
better than wood, PVC, PB or other common
building materials. It will not support combustion;
therefore, it cannot be the source of a fire or
cause a fire to spread.
Does not contribute to flashover

CPVC SPRINKLER
HEAD 90 ELBOW

CPVC BACK-TO-BACK
SPRINKLER
HEAD ADAPTER

Low smoke generation


Toxicity is extremely low when compared
with common building and finishing materials;
equal to wood and less than wool or cotton
(University of Pittsburgh protocol)

CPVC MALE ADAPTER

SPIGOT SPRINKLER
HEAD ADAPTER
(SLIP X FIPT)

FEMALE SPRINKLER
HEAD ADAPTER
(EAST)

CPVC TO COPPERFEMALE ADAPTER


(SLIP X FEMALE)

FEMALE SPRINKLER
HEAD ADAPTER
(WEST)

17

WORLDWIDE HEADQUARTERS
Tyco Fire Protection Products
1400 Pennbrook Parkway
Lansdale, PA 19446
215-362-0700, 800-523-6512
Fax 215-362-5385
www.tyco-fire.com

UNITED STATES DISTRIBUTION CENTERS


Norcross, GA
Norristown, PA
Jessup, MD
Carol Stream, IL
Coppell, TX
Kent, WA
Avon, MA
Pompano Beach, FL
Murray, UT
Parma, OH
Kansas City, MO

CANADA REGIONAL HEADQUARTERS


871 Equestrian Court, Unit 1A 2nd Fl.
Oakville, ON L6L 6L7

UNITED KINGDOM
Regional Headquarters
Grimshaw Lane, Newton Heath
Manchester M40 2WL

www.tyco-rapidresponse.com
1-877-GET-TYCO (1-877-438-8926)

Copyright2014-2015TycoFireProductsLP.AllRightsReserved.

TFP2015010

S-ar putea să vă placă și