Sunteți pe pagina 1din 58

Solar Control, LLC | 888-550-4836

Electronic Control Solutions – Table of Contents

Table of Contents
Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.01
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.02
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.03 – 4.08
Line Voltage Switching – Hardwired . . . . . . . . . . 4.09 – 4.11
Low Voltage Controls – Hardwired . . . . . . . . . . . 4.12 – 4.13
MLC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.14 – 4.19
IQ/MLC . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.21 – 4.32
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . 4.33 – 4.34
Low Voltage Controls – Busline . . . . . . . . . . . . . . . . . . . 4.35
I•CON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.35 – 4.40
Wireless Controls . . . . . . . . . . . . . . . . . . . . . . . . . 4.41 – 4.42
Line Voltage Motors . . . . . . . . . . . . . . . . . . . . . . . . 4.43
Wireless Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.44
Peripherals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.45
Whole Building Systems – AAC . . . . . . . . . 4.08, 4.46 – 4.48
ElectroShade Electrical Notes
for Standard Motors . . . . . . . . . . . . . . . . . . . . . . . 4.49 – 4.51
ElectroShade System Specs for Standard &
Intelligent Motor Control Systems . . . . . . . . . . . . 4.52– 4.56

Third Party Intergration . . . . . . . . . . . . . . . . . . . . . . . . .4.57.0


Lighting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.57.01
A/V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.57.02
HVAC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.57.03
BMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4.57.04

MechoShade Systems, Inc.


42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.01
MS2200 - 4/1/04

© 2004, MechoShade Systems, Inc., Long Island City, NY. Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

Introduction: MechoShade Electronic Control Systems

IBM A/FE Headquarters – Pleasantville, NY


Edward L. Barnes Associates, PC

This 1972-1973 project incorporated


MechoShade Systems, inc. automated Solar
Shades with Analog Solar Control systems.
It was the precursor to the AAC SolarTrac™.

OPEN SOURCED SOLUTIONS – for safety and reliability. The motors into a variety of third party Lighting,
STANDARD TUBULAR MOTORS used in MechoShade solutions possess HVAC, A/V and Building Management
MechoShade features control solutions agency approvals covering the entire Systems. MechoShade has a growing
with open source, line voltage tubular motor “tip-to-tip” including: motor list of industry partnerships with third
motors. MechoShade control systems construction and performance (UL1004), party companies offering solutions which
possess over 30 years of experience in thermal overload protection (UL 2111) not only work with MechoShade
successfully employing these standard and operator design with respect to products and systems, but also have
line voltage motors. window and drapery applications been certified by MechoShade for their
(UL325). No other motors in the industry capability to reliably access and employ
By developing intelligent and adaptive
offer this level of safety and reliability the features available from these
control algorithms the company has
assurance. products. In addition, these companies
overcome the alignment and positioning
have agreed to partner with MechoShade
limitations associated with these MechoShade also goes one step further
from a training and field support
asynchronous standard motors, thus than its competition to ensure that not
standpoint to provide an industry-wide
eliminating the need for expensive, only do the motors meet these require-
technical support team dedicated to
proprietary and single-sourced encoded ments, but so do the controls, support
making sure the customer is never left
motors within our products. In addition, components and the resulting SYSTEM
without responsive and knowledgeable
standard line voltage motors offer the including the recommended wiring and
support in the field.
broadest range of torque and speed operating methods. Therefore, on every
variations which enables MechoShade MechoShade control system, can be
to provide the most extensive line of found the ETL Mark identifying system- TECH SUPPORT
motorized shading solutions in the tested conformance to the highest
No other shading or controls company
industry. industry standards.
provides a greater range of product
capability, experience or dedication
SEAMLESS INTEGRATION AND toward meeting the needs of its
AUTOMATION customers. As such, MechoShade’s
Sales Representatives and Technical
MechoShade has designed its controls
Support Staff are always available to
to integrate with a variety of automation
RELIABILITY AND SAFETY – sensors in order to enhance comfort,
serve a consulting role to the A&D
SYSTEM TESTING convenience and energy efficiency that
community in order to help solve or
enhance current and future project
MechoShade products only employ UL supports daylighting, energy conservation
opportunities.
Recognized and CSA Approved motors and Green building design. Furthermore,
that meet the strictest industry standards the controls offer seamless integration
Continued ☞
MechoShade Systems, Inc.
42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.02
MS2200 - 6/1/04

© Copyright 2004, MechoShade Systems, Inc., Long Island City, NY. MechoShade and ElectroShade are registered trademarks of MechoShade Systems, Inc.
Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

Overview: MechoShade Electronic Control Solutions

MechoShade motorized window and skylight shading solutions are designed for both commercial and residential window
management projects. These system solutions optimize the application of standard, line voltage (120/240 VAC, 50/60 Hz)
tubular motors with ElectroShade® hardware and fabric. MechoShade Systems, Inc. is a vertically integrated company
that carries the broadest range of shading hardware and control electronics options in the industry. This enables the company
to offer a wide selection of customizable componentry to best meet the features and budget associated with any automated
shading project. In addition, the controls are designed to offer seamless integration into most third party Lighting, HVAC, A/V and
Building Management Systems thus providing the ultimate in terms of occupant comfort and intelligent building performance.

MechoShade’s standard electronic switching and control product line offers solutions which range from single office to
whole building while accommodating various levels of motor grouping and shade alignment requirements. Each solution
employs a specific wiring/interconnect methodology which tends to optimize it for either retrofit, renovation or new construction
applications. The wiring methodology offers distinct advantages and disadvantages in terms of product and installation economy,
ease of troubleshooting, security, integration, product functionality and flexibility. MechoShade offers four (4) basic product
categories defined by their interconnection methodology:

Controls Selection Guide


Line Voltage Low Voltage Low Voltage
Wireless
FEATURES: Hardwired Hardwired Networked
AC Switch MLC IQ/MLC™ I•Con RTS
Scale Room/Multi-Room ✓ ✓ ✓ ✓ ✓
Floor/Multi-Floor ✓ ✓ ✓
Whole Building ✓
Flexibility Hardwired ✓ ✓ ✓
DIP Switch Address ✓ ✓
Fully Software Addressable ✓ ✓
Grouping (M/I/G/OG)* M M M/I/G/OG M/I/G/OG M/I/G/OG
Number of Motors/Controller N/A 4 4 2
Number of Addresses N/A N/A 5 9 6
Number of Control 1 1 5 255+ 12
Groups per Motor
Max Number of Motors 2 100 40 100+†† 100+††
Controlled by One Switch
Alignment Alignment Positions** 2 2 5 6 3
UniformMode™† ✓ ✓
Integration Dry Contact ✓ ✓ ✓ ✓
RS232/485 ✓ ✓ ✓ ✓
Accessories Timer – 7-Day ✓ ✓ ✓ ✓
Photo Sensor Ctrl. (SAC Unit) ✓ ✓ ✓ ✓
IR Controller ✓ ✓ ✓ ✓
RF Controller ✓ ✓ ✓ ✓
Safety UL/CSA/ETL Systems Testing ✓ ✓ ✓ ✓ ✓
* M= Master; I=Individual; G=Group; OG=Overlapping Group ** Includes both Full-Up and Full-Down.
† Shades will only stop Full-Up, Full-Down and Preset Positions. †† Contact MechoShade Systems for Specifics.

Furthermore, MechoShade also offers a PC-based Solar Tracking System that is capable of integrating any of MechoShade’s
Low Voltage Controls into a whole building control system customized to a building’s specific geodesic location and focused on
employing proactive and reactive routines to optimize energy efficiency, comfort and view throughout the building. Continued ☞

MechoShade Systems, Inc.


42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.03
MS2200 - 6/1/04

© 2004, MechoShade Systems, Inc., Long Island City, NY. I•CON and UniformMode are trademarks of MechoShade Systems, Inc..
Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

Overview: MechoShade Electronic Control Solutions

115 VAC (230 VAC)

M M
SWITCHES
C US
Since 1876

Master

LINE VOLTAGE SWITCHING


Focus: Local control of one or two motors
• Full Up / Full Down Control
• Momentary or Maintained Control*
• 2-Motor Control Groups Maximum
• Variety of Switch Styles

☞ LINE VOLTAGE SWITCHES – HARDWIRED


See pages 4.09 to 4.11 for more details.

115 VAC (230 VAC)


C US
Since 1876

M M M M

12VDC
Master

MLC

Daisy Chained MLC


MLC™
* Momentary Control Switches
Focus: Master Control of return to the “Neutral” or “OFF”
position when the toggle is
Small / Large Motor Groups released. Maintained Control
Switches remain in the position
• Daisy Chain 4-Motor Controllers – Master Control - Up to 100 Motors that has been set continuing to
power the motor until the shade’s
• Full UP / Full DOWN Control w/ Momentary or Maintained Control* upper or lower limit has been
reached.
• Variety of Automation Sensor Interfaces
• Dry Contact Integration Into 3rd Party Control Systems – See Page 4.57 For Details
• Integrates With AAC

Accessory Controls: (Please see pages 4.33-4.34 and 4.45 for details.)
• Infrared and Radio Frequency Remote Controllers
• Solar Activated Controller (SAC)
• Timers

☞ LOW VOLTAGE CONTROL – HARDWIRED


See pages 4.14 to 4.19 for more details. Continued ☞
MechoShade Systems, Inc.
42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.04
MS2200 - 6/1/04

© Copyright 2004, MechoShade Systems, Inc., Long Island City, NY. MechoShade and ElectroShade are registered trademarks and MLC is a trademark of MechoShade Systems, Inc. RTS is a trademark of its respective company.
Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

Overview: MechoShade Electronic Control Solutions

12VDC 115 VAC (230 VAC)


C US
Since 1876

M M M M 1 UP / Limit
2 25% or Custom
3 50% or Custom
Local Local Local 4 75% or Custom
5 DOWN / Limit
IQ/MLC

Master Daisy Chained


IQ/MLC
IQ/MLC™
Focus: Individual/Group and Master Control
of Small / Large Motor Groups
• Daisy Chain 4-Motor Controllers – Up to 40 Motors per Master Switch
• Multi-Level Control
Individual, Group and Master
- Master Switching
SWITCHES - 4 Local / Group Switching
• 5 Alignment Positions
3 Programmable Mid-Window Alignment Positions Plus Full Up and Full Down
• Normal / Uniform Operating Modes
• Reconfigure Motor Grouping Without Rewiring
• Variety of Automation Sensor Interfaces
• Dry Contact Integration into 3rd Party Control Systems – See Page 4.57 For Details
• RS232 / 485 Integration into 3rd Party Control Systems – See Page 4.57 For Details
• Integrates with AAC SolarTrac™

Accessory Controls: (Please see pages 4.33-4.34 and 4.45 for details.)
• Infrared and Radio Frequency Remote Controllers
• Solar Activated Controller (SAC)
• Timers

☞ LOW VOLTAGE CONTROL – HARDWIRED


See pages 4.21 to 4.32 for more details. Continued ☞
MechoShade Systems, Inc.
42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.05
MS2200 - 6/1/04

© 2002, MechoShade Systems, Inc., Long Island City, NY. IQ/MLC is a trademark of MechoShade Systems, Inc. Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

Overview: MechoShade Electronic Control Solutions

C US
Since 1876

I•CON™ – 2-Way Communication Bus Line System


Low Voltage Conrol System
Focus: For projects that are either large scale motorization or automation
SWITCHES
with potential requirements for flexibility or reconstruction, robust addressable
network, flexible wiring, free topology,
• Networked, Addressable 2-Motor Controllers º Manual Addressing thru DIP Switches
• Free Topology Low Voltage Twisted Pair º Employ Software Addressing Using the
Control Wiring Handheld Programmer
º Cost Effective and Flexible Wiring Layout Helps • Networked Control for Building-Wide and
Reduce Installation Costs Complex Control Grouping
• Multi-Level, Overlapping Control • Hardwired Control Option for Cost Effective
º Individual, Group and Master Control Local Control Grouping
º Each Motor can Belong to 9 Different • Variety of Automation Sensor Interfaces
Control Groups • Dry Contact Integration into 3rd Party Control
• 6 Alignment Positions Systems – See Page 4.57 For Details
º 4 Programmable Mid-Window • LonWorks Integration into 3rd Party Control
Alignment Positions Systems – See Page 4.57 For Details
• Normal / Uniform Operating Modes • Integrates with AAC SolarTrac™
• Reconfigure Motor Grouping Without Rewiring or
“Climbing a Ladder”

Accessory Controls: (Please see pages 4.33-4.34 and 4.45 for details.)
• Infrared and Radio Frequency Remote Controllers
• Solar Activated Controller (SAC)
• Timers

☞ LOW VOLTAGE CONTROL – BUSLINE See pages 4.35 to 4.39 for more details. Continued ☞
MechoShade Systems, Inc.
42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.06
MS2200 - 6/1/04

© 2002, MechoShade Systems, Inc., Long Island City, NY. I•CON is a trademark of MechoShade Systems, Inc.Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

Overview: MechoShade Electronic Control Solutions

Wireless Controls – Radio Remote Wireless Network


RTS™
Wireless/RTS™ Motors

WIRELESS MOTORS AND CONTROLLERS


Focus: Individual/Group & Master Control of Small/Medium Motor Groups,
Difficult to Wire Installations
• Eliminates Control Wiring
• 3 Alignment Positions
º 1 Programmable Mid-Window Alignment Position
• Perform Motor Grouping Without Rewiring or “Climbing a Ladder”
º Employs Wireless Software Addressing
• Variety of Automation Sensor Interfaces – Sun Activated Timers (SAC), Wind Activated Timers (WAC)
• Dry Contact Integration into 3rd Party Control Systems – See Page 4.57 For Details
• Distributed Control Intelligence within the Motor
• Eliminates Wiring to an Intermediate Controller
• Allows Daisy-Chain Wiring of Power to Motors

RTS™
Standard Motors

Standard RTS
Motor Motor

RTS single motor


controller/receiver

Focus: Allows integration of standard motors with RTS controllers.

☞ WIRELESS CONTROL – NETWORKED See pages 4.41 to 4.45 for more details. Continued ☞
MechoShade Systems, Inc.
42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.07
MS2200 - 6/1/04

© Copyright 2004, MechoShade Systems, Inc., Long Island City, NY. ElectroShade and MechoShade are registered trademarks of, andIMCS, IQ/MLC, MLC and SolarTrac are trademarks of, MechoShade Systems, Inc.
RTS is a trademark of its respective company. Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

Overview: MechoShade Electronic Control Systems


WindowManagement™ with AAC SolarTrac™
MechoShade's AAC SolarTrac™ System, is a software based control system, designed 2:15
to automatically adjust the position of the shades incrementally on the window to
maximize view and daylight while protecting people and work surfaces from direct sun
and excessive brightness and glare. AAC SolarTrac can react to local climactic vari-
ables such as sunny or cloudy conditions.

2:40

The AAC SolarTrac adjusts shades incrementally on the window in accordance with the solar 3:45
profile angle and BTU load relative to each zone or orientation.

Dec 12:00 p.m. June 12:00 p.m.


At 2:15 p.m. the AAC SolarTrac has
lowered the shades in reaction to the
sun’s shift to the west elevation. The light
dimming system senses enough daylight
for the overhead lights to remain off.

At 2:40 p.m. the sun moves further onto


the West elevation, becoming more direct.
The AAC SolarTrac lowers the shades to
the next position, to control the solar
The position of the shades is determined for each zone based on the window geometry, ori- penetration into the work area. The light
entation, glazing optical properties, allowable solar penetration, and real-time sky conditions, dimming system continues to keep the
ie sunny or cloudy. The goal is to provide shading on the window when and where needed, lights off due to adequate natural light
while leaving as much of the window unshaded in order to maximize view and control glare. in the space.
In other words....total WindowManagement.
At 3:45 p.m. the AAC SolarTrac reacts
to the solar gain and glare conditions
Sky Analysis created as the sun sets, by lowering the
Through the use of three roof mounted solar shades to the maximum down position.
sensors, AAC SolarTrac compares the actual The light dimming system has activated
measured solar radiation (sunshine) vs AHSRAE
some of the lights, while leaving others
calculated clear sky radiation. The AAC SolarTrac
uses this data to determine “clear” or “cloudy”
off, based on the light levels achieved
sky conditions and operates accordingly. If it is in each area.
determined to be sunny, then the shades move
to their proper positions. If cloudy, they would
typically be programmed to roll up. Time delays
built into the program prevent excess shade
movement on days with variable conditions. For more information on AAC
SolarTrac see pages
4.46 – 4.48, 4.50 and 4.55.

MechoShade Systems, Inc.


42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.08
MS2200 - 6/1/04

© Copyright 2004, MechoShade Systems, Inc., Long Island City, NY. MechoShade and ElectroShade are registered trademarks of, and IQ/MLC, IMCS, Intelligent Motor Control System, MLC and SolarTrac are trademarks of,
MechoShade Systems, Inc. *Windows is a trademark of Microsoft Corporation, One Microsoft Way, Redmond, Washington 98052-6399 U.S.A. All rights reserved.Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

Hardwired: Line Voltage Switching

Motorola Cellular Subscriber Facility, IL


Globetrotter’s Engineering – Architects

Line Voltage Switching – Hardwired (Direct Wiring)


MechoShade possesses a variety of Line Voltage Switches requirements. If mid-window settings are required the switch
for basic control of shades equipped with standard, line must run in a supervised fashion so that the user stops the
voltage (120/240 VAC, 50/60 Hz) tubular motors. The motors shade when it reaches the desired position. These switches
wire directly to the switches that control them in a hardwired, can operate up to two separate motors simultaneously and
homerun (direct) fashion and therefore do not require any come in a variety of styles and colors to suit virtually any
intermediate controller electronics. The switches are single- décor.
pole/double-throw (SPDT) and double-pole, double-throw
(DPDT) center-off devices that offer the control of one or two All switch variations meet the various local and national
motorized shading assemblies in an isolated fashion from a building codes for indoor usage. Each one also has been
common switch. certified to UL and CSA recognized component standards.
Select switches have been further qualified by ETL under
In general, these systems represent the most economical stringent system testing requirements with regard to their
control solution and are best wired into renovate/new application under UL325 and CSA 22.2 along with all of
construction projects where the switches are controlling MechoShade’s available motors and hardware. These are
only one or two motors or a multi-banded group of shades. the E-Switch™ Series of switches which provide the installer
Shade operation is typically full-up/full-down where absolute and end user with additional confidence that the entire
alignment with another shade group is not a priority. MechoShade solution and the methods used to install
Switches can be selected for operation in a momentary and wire it meet the strictest safety and reliability
or maintained fashion to accommodate the user’s standards in the industry.

Continued ☞
MechoShade Systems, Inc.
42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.09
MS2200 - 6/1/04

Copyright © 2004 MechoShade Systems, Inc. “MechoShade,” and “ElectroShade,” are registered trademarks of MechoShade Systems. “MLC” and “IQ/MLC” are trademarks of MechoShade Systems.
Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

Hardwired: Line Voltage Switching


Line Voltage Switching for One Standard Type Motor with One Double-Pole Switch

C US
Since 1876

See Page 4.11.

Note:
Drawings are incomplete unless both pages of this Wiring Diagram,
4.10 – 4.11, plus the Electrical Notes pages 4.49 – 4.51 are included.

MechoShade Systems, Inc.


42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: www.mechoshade.com 4.10
MS2200 - 6/1/04

© Copyright 2004, MechoShade Systems, Inc., Long Island City, NY. ElectroShade and MechoShade are registered trademarks of MechoShade Systems, Inc. Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

Hardwired: Line Voltage Switching


Line Voltage Switching for Two Standard Type Motors with One Double-Pole Switch

C US
Since 1876

Note:
Drawings are incomplete unless both pages of this Wiring Diagram,
4.10 – 4.11, plus the Electrical Notes pages 4.49 – 4.51 are included.

MechoShade Systems, Inc.


42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.11
MS2200 - 6/1/04

© Copyright 2004, MechoShade Systems, Inc., Long Island City, NY. ElectroShade and MechoShade are registered trademarks of MechoShade Systems, Inc. Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

Hardwired: Low Voltage Controls

Bank Boston, Sao Paulo, Brazil


SOM-Chicago – Architects

Low Voltage Controls – Hardwired (Direct Wiring)


MechoShade Systems, Inc. possesses a diverse line of Low voltage connections do not typically require conduit
hardwired, low voltage controls. All offer enhanced operation or junction boxes (local code dependent). This eliminates
of motorized shades equipped with standard, line voltage installation hardware costs and makes the installation
(120/240 VAC, 50/60 Hz) tubular motors. Each line voltage process easier and more flexible for future changes.
motor is directly powered by a dedicated connection to a motor
controller. The motor controller establishes the shade position Large, Multi-Level Control Groups
based on input from a low voltage network of contact closure Some low voltage control networks are isolated from the line
based switches and accessories such as automation sensors voltage power mains (ie. I•CON) which helps to ensure that
(ie. Photocells, occupancy sensors, etc.), timers/schedulers, controllers operating from different phases of the building’s
wireless remote controls and other third party controllers. incoming power can be interconnected reliably to form large
This is considered to be a hardwired control network where shade groups controlled by a common switch. In addition,
the inputs on the motor controller are wired directly to the often times the same shade can be part of more than one
low voltage switches and accessories that actuate them. shade group depending on the design of the controller
In general these types of control solutions are best applied (I•CON). This is called multi-level control which enables a
to renovate/new construction projects where wiring can motor/shade to be controlled as an individual shade, part of
more easily be installed behind the drywall. a group of shades or even be controlled from within a master
switching circuit that includes all of the shades within a
Flexible and Less Costly to Install control network.
Low voltage control offers many installation advantages over
line voltage control including safety, simplicity, flexibility and Advanced Control Logic
ultimately cost. Low voltage control connections operate at Low voltage controllers such as the IQ/MLC are designed
voltages that are designed to be non-hazardous. Therefore, using microprocessors in order to provide more flexibility in
it does not require a licensed electrician to pull this cabling the operational features available to the user. For instance,
and install it although it is highly recommended that a trained if someone wanted to position a shade in the middle of the
professional perform the job in order to minimize problems. window a typical line voltage switch may require the user to

Continued ☞
MechoShade Systems, Inc.
42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.12
MS2200 - 6/1/04

Copyright © 2004 MechoShade Systems, Inc. “MechoShade,” and “ElectroShade,” are registered trademarks of MechoShade Systems. “MLC” and “IQ/MLC” are trademarks of MechoShade Systems.
Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

Hardwired: Low Voltage Controls


actuate the switch until the shade hits the desired point. This with other manufacturers’ controllers or systems to provide
is called supervised operation. Within a low voltage controller enhanced functionality and features. This can include operation
the user may have the ability to push a single button with controllers for Lighting, HVAC, A/V, Security, Life/Fire/
momentarily which will cause the shade to move directly to Safety or more generally into Building Management Systems
a specific position on the window – ie. half-way down. (BMS). The methods available for seamless integration of
Depending on the controller these stop positions may be MechoShade’s controllers into these other systems include
programmable and may offer assured alignment opportunities dry contact closures or RS232 / 485 from a software stand-
with surrounding shades as well – regardless of varying point. These same methods are also available to integrate with
window heights. various environmental sensors (photosensors, occupancy
sensors, radiometers, thermostats, etc.) in order to provide
Other opportunities afforded by a microprocessor-based automated convenience, comfort and/or energy management
controller may include advanced, intelligent user interfaces control for example supporting Title 24 or Green Building
such as keypads and LCD touchscreens. Various operating applications.
modes may also be offered such as Uniform Mode where a
shade cannot be stopped anywhere on the window except Systems Testing – Safety and Reliability
at full up/full down and the established mid-window stop All of MechoShade’s low voltage controllers have been tested
positions. by ETL to meet UL325 and CSA 22.2 system requirements to
ensure the installer and end user that the entire MechoShade
Seamless Integration solution including the hardware, motors and controls in addition
MechoShade’s low voltage controllers are designed to be to the methods used to install and wire it meet the strictest
open, interoperable devices which can work in coordination industry safety and reliability standards.

Quick Selection Guide: Low Voltage Controls – Hardwired


Feature Description MLC IQ/MLC
Daisy Chain Supports motors from separate controllers operating simultaneously
X X
via the same low voltage input (ie. switch, sensor, Lighting control)
# Motors/Controller
The number of motors independently connected to a controller 4 4
Max Controllers/
Switch Input The number of controllers which can be daisy chained to a single switch 25 10
Master Control Operates all motors within a controller simultaneously X X
Individual Control Operates each motor within a controller independently – Local Control X
Group Control Operates a combination of motors within a controller simultaneously X
Wiring DIP Switch
Reconfigurable How does one change the “Switch - Motor” assignments?
/Wiring
The number of points where 2 or more independent shades can be
Alignment Positions 2 5
made to align including Full Up and Full Down
Programmable, Mid- The number of Alignment Positions within the span of the window
3
Window Positions where a single button press can align a group of shades
Assured Alignment Can the controller support repeatedly aligning groups of shades X
Can each motor of the controller be set to only allow the shade to
Uniform Mode X
stop at the Alignment Positions?
Dry
Integration with Methods available to integrate seamlessly with third party control systems Dry
Contact
third party controls such as Lighting, HVAC, A/V and Building Management Systems (BMS) Contact
RS232/485
Integration with low Integrates with automation sensors, timers, remote controls, etc.
X X
voltage accessories over the low voltage control network

MechoShade Systems, Inc.


42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.13
MS2200 - 6/1/04

Copyright © 2004 MechoShade Systems, Inc. “MechoShade,” and “ElectroShade,” are registered trademarks of MechoShade Systems. “MLC” and “IQ/MLC” are trademarks of MechoShade Systems.
Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

Hardwired: Low Voltage Control Systems – MLC™


Low Voltage Control (Hardwired)
MLC™
Features:
- Master Control for 4 115 VAC (230 VAC)
C US
standard line voltage Since 1876

tubular motors
- Full UP/Full DOWN
Control w/ Supervised M M M M

Mid-Window Positioning
- Daisy chain to orchestrate
master control on up to 12 VDC
100 motors Master
- Variety of Automation
Sensor Interfaces
- Dry Contact Integration
into Lighting and other
3rd Party Control
Systems

Description
The MLC offers enhanced functionality over Line Voltage Switch controls by providing master control of large groups of
motors while also enabling the integration of low voltage sensors, timers and third party control systems for higher level
functionality. The device is designed to accommodate cost conscious applications involving the simultaneous movement
of multiple shades where shade operation is typically full up/full down while mid-window positioning and guaranteed alignment
is not a driving concern. Blackout shades for A/V conference rooms often require this type of operation. These controllers
are best suited for renovation/new construction projects where the control wiring can be conveniently run behind the drywall.
Surface mount raceway and drop ceilings can enable these devices to be installed in retrofit projects as well.

Detail
MechoShade’s MLC is a cost effective, low voltage controller offering master control of four (4) standard, line voltage
motors (120/240 VAC, 50/60 Hz). The device is equipped with a low voltage control network that enables the positioning of
motors in an UP/DOWN fashion with supervised mid-window positioning from either a single maintained-contact switch or
multiple momentary center-off switches and/or low voltage accessories (ie. automation sensors, timers, remote controls, etc.).
Up to 25 MLCs (100 motors) can be daisychained over the low voltage network to operate from a single switch connection.
MechoShade offers a variety of maintained-contact and momentary center-off switches in a wide range of colors and styles
to accommodate virtually any décor. In addition, the MLC can operate with a variety of third party contact closure switches
and controls supporting seamless integration into Lighting, HVAC, A/V and Building Management Systems (BMS).

MLCs provide control and power distribution functionality for the four (4) non-proprietary, line voltage motors they operate.
Each motor is wired directly to its own dedicated set of fused power connections. The internal circuitry protects each motor
and ensures the maximum lifetime out of the shade motor and the system. The low voltage control network (12 VAC) offers
a cost effective opportunity to extend the control of the motors through contact closure devices into multiple locations and
multiple sources. Control switches and low voltage accessories wire directly to the MLC input in a hardwired fashion for
ease of troubleshooting.

The MLC has been qualified by ETL under stringent system testing requirements with regard to UL325 and CSA 22.2 along
with all of MechoShade’s available motors and hardware systems. This provides the installer and end user with additional
confidence that the ENTIRE MechoShade solution and the methods used to install and wire it meet the strictest safety and
reliability standards in the industry.

Continued ☞
MechoShade Systems, Inc.
42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.14
MS2200 - 6/1/04

© Copyright 2004, MechoShade Systems, Inc., Long Island City, NY. MechoShade and ElectroShade are registered trademarks of, and MLC and IQ/MLC are trademarks of, MechoShade Systems, Inc.
Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

Hardwired: Low Voltage Control Systems – MLC™


MLC – Features and Benefits
Low voltage switching for standard motors using a four (4) motor Motor Logic Controller™ (MLC™).

MASTER CONTROL MASTER CONTROL MASTER CONTROL


WITH UP TO WITH TWO OR MORE MLC S WITH SUN ACTIVATED
TWO SWITCHES ON A SINGLE SWITCH AND CIRCUIT CONTROL
ON AN MLC
1 2 3 4 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
115 VAC M M M M M M M M 115 VAC M M M M M M M M 115 VAC M M M M
(230 VAC) (230 VAC) (230 VAC)

J J J J J
J J J J J
J J J J J
J J J J J

MLC A MLC A MLC B MLC A MLC B

12 VAC 12 VAC 12 VAC 12 VAC


12 VAC 12 VAC
STOP
STOP

AUTO
AUT SET
Solar Activated Controller
(SAC)
SAC
Momentary Maintained
Contact Switch Contact Switch Manual/Auto
(Hold for operation) Switching Modes

MLC – Line Motor Controller™ (MLC™)


MechoShade’s® economical, low voltage four motor MLCs may be used to incorporate:
controller offers master control for up to four motors • Solar-activated control.
on either one maintained switch or multiple momentary, • Remote control (IR/RF).
center-off switches. Up to 100 motors may be wired together • A low voltage interface with A/V
on a single switch circuit by daisy chaining MLC’s. Shade and dimming systems.
operation is by UP/DOWN switch activation with mid-window
settings accomplished in a supervised fashion.

Integration with Third Party Controls (ie. Lighting, HVAC, A/V for Home Automation, and Building Management Systems.)
(See page 4.29.)
MLC™ (Motor Logic Controller) using Dry Contact Closures
• Provide two (2), 12 VAC, maintained
dry contacts.
• To activate the shades, provide a main-
tained contact closure for the shades
to move.
• The shades will continue to move until
they reach their internal limit switches
or are otherwise stopped by opening
the contacts.
• Master switching only.

Continued ☞
MechoShade Systems, Inc.
42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.15
MS2200 - 6/1/04

© Copyright 2004, MechoShade Systems, Inc., Long Island City, NY. MechoShade and ElectroShade are registered trademarks of, and IQ/MLC, MLC and Motor Logic Controller are trademarks of MechoShade Systems, Inc.
Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

Hardwired: Low Voltage Control Systems – MLC™


Typical MLC Applications

MLC with standard motors for single and multibanded shades


TM

MASTER CONTROL ONLY

1 1 2 3 1 1 2 3

M1 M 2 M 3 M 4

J J J J
120V 120V 120V 120V

MLC A
12 VAC
Lighting or Dry Contact 120 VAC
A/V System Closure J (230 VAC)

MASTER
A

MASTER CONTROL ONLY a) Master Switch A controls motors 1-4 simultaneously.


b) A/V System, with a dry contact interface, controls motors 1-4 simultaneously.

MASTER CONTROL ONLY (UNLESS WIRED AS TWO SEPARATE MLC s EACH WITH ITS OWN SWITCH)

1 1 2 3 1 1 2 3 1 1 2 3 1

M1 M 2 M 3 M 4 M 5 M 6 M 7

J J J J J J J
120V 120V 120V 120V 120V 120V 120V

MLC A MLC B
12 VAC
Lighting or Dry Contact 120 VAC 120 VAC
A/V System Closure J (230 VAC) (230 VAC)
12 VAC
MASTER
A

MASTER CONTROL ONLY a) Master Switch A controls motors 1-7 simultaneously.


b) A/V System, with a dry contact interface, controls motors 1-7 simultaneously.

Continued ☞
MechoShade Systems, Inc.
42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.16
MS2200 - 6/1/04

© Copyright 2004, MechoShade Systems, Inc., Long Island City, NY. MechoShade and ElectroShade are registered trademarks of, and MLC is a trademark of, MechoShade Systems, Inc.
Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

MLC™ – ElectroShade® Wiring Diagram For Std. Motors


MLC – Wiring Diagram
Low voltage switching for one to four standard type motors on one switch
using an MLC™ four motor controller.
WHITE

BLACK (DIRECTION 1) 115 VAC (230 VAC)

MOTOR #1 MOTOR #2 MOTOR #3 MOTOR #4

MOTOR LEAD
1 – 1’0" DISCONNECT
PRE-WIRED PLUG
TO MOTOR BLACK
2

J-BOX
LEAD J-BOX RED RED (DIRECTION 2)
– 5’0"
WHITE

Note: FUSES:
The black and red motor lead Reverse the black and red motor
lead wiring for Direction 2: F1-F4 ARE
wiring shown is for Direction 1:
GMC-5 AMP
- Right-Hand Drive Regular-Roll - Left-Hand Drive Regular-Roll C US
- Left-Hand Drive Reverse-Roll - Right-Hand Drive Reverse-Roll F5 IS GMC-
1-/2 AMP. Since 1876

See indications next to each motor Red & Black terminal.

18
BLACK
17
F2 5AMP

F3 5AMP

16 8
115 VAC (230 VAC)
15 7
RED
6
14
MLC 5
13
12 VAC 4
12
3
F1 5AMP

F4 5AMP

11 WHITE
2
115 VAC (230 VAC)
DPDT OR BLACK 10
F5 .1/2AMP
1
SPDT SWITCH WHITE
MOMENTARY 9
CENTER OFF
GROUND
OR
MAINTAINED MLC POWER REQUIREMENT:
Note: Drawings are
115 VAC MOTOR LEAD –1’0" (30CM) incomplete unless
(230 VAC) OUTPUT: LONG PRE-WIRED
INPUT both pages of this
TO MOTOR
NOTE: LINE VOLTAGE INPUT: 115 VAC, 60 HZ, Wiring Diagram,
115 VAC, 60 HZ, 10% 3.8 AMPS PER 1 2 4.17 – 4.18, plus
1. INSTALLATION MUST
230 VAC, 50/60 HZ, 10% OUTPUT/MOTOR
COMPLY WITH ALL LOCAL the Electrical Notes
AND NATIONAL ELECTRICAL 230 VAC, 50/60 HZ DISCONNECT
CODES FOR 120 VAC (230
LOW VOLTAGE INPUT:
PLUG
pages 4.49 – 4.51
12 VAC, 8mA 1.9 AMPS PER
VAC) AND LOW VOLTAGE OUTPUT/MOTOR are included.
WIRING REQUIREMENTS. 2 3
FUSES (MOTOR)......... 5 AMP PER 120V MOTOR J-BOX LEAD
2. MAXIMUM LOW VOLTAGE
5 AMP PER 230V MOTOR –5’0" (152CM)
CABLE IS 400 FEET
FUSES CONTOLLER.. 1/2 AMP LONG
CUMULATIVE.
Continued ☞
MechoShade Systems, Inc.
42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.17
MS2200 - 6/1/04

© Copyright 2004, MechoShade Systems, Inc., Long Island City, NY. MechoShade and ElectroShade are registered trademarks of, and MLC and Motor Logic Controller are trademarks of, MechoShade Systems, Inc.
Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

MLC™ – ElectroShade® Wiring Diagram For Std. Motors


MLC – Wiring Diagram
How to connect two or more four (4) motor MLC™ Motor Logic Controllers
having five or more standard type motors on one switch.

WHITE

BLACK (DIRECTION 1) 115 VAC (230 VAC)

MOTOR #1 MOTOR #2 MOTOR #3 MOTOR #4

MOTOR LEAD
1 – 1’0" DISCONNECT
PRE-WIRED PLUG
OPTIONAL TO MOTOR BLACK
2
ELECTRICAL TERMINATION

JUNCTION BOX
(BY OTHERS) 3
OPTIONAL PLUG-IN
RECEPTACLE
J-BOX
DISCONNECT
PLUG LEAD J-BOX RED
MOTOR – 5’0" RED (DIRECTION 2)
LEAD
WHITE

2 1
18
BLACK
17
F2 5AMP

F3 5AMP

16 8
115 VAC (230 VAC)
15 7
RED
12 VAC 6
14
MLC A 5
13
4
12
3
F1 5AMP

F4 5AMP

11 WHITE
2
BLACK 115 VAC (230 VAC)
DPDT OR 115 VAC 10 1
WHITE F5 .1/2AMP
SPDT SWITCH (230 VAC)
MOMENTARY 9
CENTER OFF GROUND
OR
MAINTAINED

WHITE

BLACK (DIRECTION 1) 115 VAC (230 VAC)

ALL 115 VAC


MOTOR #5 MOTOR #6 MOTOR #7 MOTOR #8
SOURCE
WIRING
MUST BE
MOTOR LEAD
IN PHASE 1 – 1’0" DISCONNECT
PRE-WIRED PLUG
IF TWO OR TO MOTOR BLACK
2
MORE MLC S
ARE USED
3
ON THE
SAME J-BOX
CONTROL. LEAD J-BOX RED
– 5’0" RED (DIRECTION 2)
WHITE

18
BLACK
17
F2 5AMP

F3 5AMP

Note: 115 VAC (230 VAC)


16 8
15
Drawings are 7
RED
12 VAC 6
incomplete unless 14
MLC B 5
both pages of 13
4
12
this Wiring Diagram, 3
F1 5AMP

F4 5AMP

11 WHITE
4.17 – 4.18, plus the BLACK
2
115 VAC (230 VAC)
Electrical Notes 115 VAC
WHITE
10
F5 .1/2AMP
1
(230 VAC) 9
pages 4.49 – 4.51
GROUND
are included.

MechoShade Systems, Inc.


42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.18
MS2200 - 6/1/04

© Copyright 2004, MechoShade Systems, Inc., Long Island City, NY. MechoShade and ElectroShade are registered trademarks of, and MLC and Motor Logic Controller are trademarks of, MechoShade Systems, Inc.
Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

Hardwired: Low Voltage Control Systems – MLC™


MLC System Summary
MLC MOTOR LOGIC CONTROLLER

FOR MASTER CONTROL OF UP TO 4 MOTORS PER MLC


The MLC System consists of: (EACH MLC MAY BE DAISY CHAINED)

MLC Four Motor Controller.


Low voltage four (4) motor controller for standard motors
with master switch control capability. Additional MLC control
circuits can be wired in parallel or series. 12 VAC, 0.3A per
switch. Input: 120 VAC, 0.5A; 240 VAC, 0.25A.
Output: 120 VAC, 3.8A max.; 240 VAC, 1.9A max.
P/N: 120V: EMLC SLMA ST SP
230V: EMLC SLSP ST SP

MLC MLC DPDT MLC DPDT


MOTOR LOGIC CONTROLLER ROCKER SWITCH ROCKER SWITCH
MLC Switch (MAINTAINED) (MOMENTARY)
Double pole, double throw momentary or maintained rocker
120V ESWX 0688 PS WH ESWX 0689 PS WH
switch for master control switching. Full up/full down or EMLC SLMA ST SP ESWX 1441 PS CW ESWX 1551 PS CW
anywhere in between shade positioning through activation
of the switch and supervised mid-window positioning is 230V
EMLC SLSP ST SP
capable. (12V) WH = WHITE
CW = COLONIAL WHITE
Maintained P/N: ESWX 0688 PS WH
ESWX 1441 PS CW
Monentary P/N: ESWX 0689 PS WH
ESWX 1551 PS CW Please See Page 4.34 for a complete listing of Switches.

Accessory Controls
• Lighting Controls
• A/V
• Solar Activated Timers (SAC)
• Seven-Day Timers
• AAC – SolarTrac™
Please see pages 4.33-4.34 and 4.44 for details.

Single Channel and Four Channel 24-Hour Digital Timer


IF and RF Remote Controls P/N: EDTI 0351 24 WH
Single Channel P/N: EIRC 1014 RA TR EDTI 0352 24 CW
Four Channel P/N: EIRC 1015 RA TR

Solar Activated Controller (SAC)


SAC w/Photo Cell P/N: ESSA 0901 ST WH
ESSA 0931 ST CW
SAC w/Photo Cell and
Switch P/N: ESSA 0827 ST WH Key Switch Digital Key Pad
ESSA 0927 ST CW Maintained P/N: ESWX RYMA PS CW P/N: ESDX 0739 IN WH
Photo Cell Only P/N: ESPC 0313 PL WH Momentary P/N: ESWX RYMO PS CW

MechoShade Systems, Inc.


42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.19
MS2200 - 6/1/04

© Copyright 2004, MechoShade Systems, Inc., Long Island City, NY. MechoShade and ElectroShade are registered trademarks of, and MLC, Motor Logic Controller and SolarTrac are trademarks of, MechoShade Systems, Inc.
Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

NOTES
___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

MechoShade Systems, Inc.


42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.20
MS2200 - 6/1/04

© 2004, MechoShade Systems, Inc., Long Island City, NY. Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

Hardwired: Low Voltage Controls – IQ/MLC™


Low Voltage Control (Hardwired)
IQ/MLC™
Features:
- Multi-Level Control for 4 standard
line voltage tubular motors
- 5 Guaranteed Alignment Points C US

(3 Programmable Intermediate Since 1876

Stops)
- Daisy chain to orchestrate
master control on up to 40 motors
- Normal & Uniform Mode
- Integrates w Sensors, Times,
Remotes, etc.
- Seamless Integration into
Lighting and other 3rd Party
Control Systems
- Integrates with AAC

Description
The IQ/MLC possesses advanced control functionality beyond that available from Line Voltage Switch activation or the MLC
low voltage controller. This device is designed to accommodate discriminating applications involving the control of individual
or groups of shades where mid-window positioning and guaranteed alignment across multiple shades is required. The IQ/MLC
is operated by a decorative, 3-button switch providing convenient, one-touch positioning of the shade to one of five (5)
alignment points on the window. The same shade can be operated individually AND by an overriding master control. A choice
of user modes can force the shade to only stop at the alignment points thus preserving the consistency of the interior and
exterior building design. These controllers are best suited for renovate/new construction projects where the control wiring can
be conveniently run behind the drywall. Surface mount raceway and drop ceilings can enable these devices to be installed in
retrofit projects as well. Reconfiguration of motor-switch grouping can be easily handled without rewiring by simply changing
a DIP switch setting.

Detail
MechoShade’s IQ/MLC is a hardwired, low voltage controller offering individual, group and master control of four (4) standard,
line voltage motors (120/240 VAC, 50/60 Hz). The IQ/MLC provides control and power distribution functionality to each motor
which independently fuses the motor and protects it from power surges, improper wiring and inappropriate activation thus
ensuring the maximum lifetime out of the shade motors and the system.

The IQ/MLC is a microprocessor-based controller equipped with a low voltage control network that enables UP/DOWN and
“one-touch” mid-window positioning of its motors through the IQMLC 3-button switch. The advanced logic capabilities of the
IQ/MLC offer five (5) alignment points across the operation of each motor including three (3) programmable mid-window
alignment points. These alignment points provide assured alignment across multiple shades – REGARDLESS OF WINDOW
HEIGHT. The controller also permits each low voltage input to be controlled using one of two different operating modes.
Normal Mode permits the shade to be stopped anywhere across the entire height of the window. Uniform Mode enables
the shade to be stopped ONLY at the alignment points thus ensuring at all times a consistent look across the window wall.

Continued ☞
MechoShade Systems, Inc.
42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.21
MS2200 - 6/1/04

© 2004, MechoShade Systems, Inc., Long Island City, NY. IQ/MLC is a trademark of MechoShade Systems, Inc. Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

Hardwired: Low Voltage Controls – IQ/MLC™


Low Voltage Control (Hardwired)

The IQ/MLC’s low voltage control network (12 VDC) offers a cost effective opportunity to extend the control of the motors
through contact closure devices into multiple locations and multiple sources. Four Local Input connections are provided to enable
individual and group control capability through DIP-switch assigned combinations of all four motors. The DIP switches are a
convenient way to alter Switch-Motor assignments without rewiring. Two Master Input connections enable simultaneous operation
of all four motors through a common switch. (Up to 10 MLCs (40 motors) can be daisy chained over the low voltage network to
operate from a single switch connection.) Switches and low voltage accessories wire directly to the Local and Master Inputs in
a hardwired fashion for ease of troubleshooting. The IQ/MLC low voltage network can operate with a variety of third party contact
closure switches, low voltage accessories (ie. automation sensors, timers, remote controls, etc.) and controls supporting seamless
integration into Lighting, HVAC, A/V and Building Management Systems (BMS).

The IQ/MLC has been qualified by ETL under stringent system testing requirements with regard to UL325 and CSA 22.2 along
with all of MechoShade’s available motors and hardware systems. This provides the installer and end user with additional
confidence that the ENTIRE MechoShade solution and the methods used to install and wire it meet the strictest safety and
reliability standards in the industry.

Continued ☞
MechoShade Systems, Inc.
42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.22
MS2200 - 6/1/04

© 2004, MechoShade Systems, Inc., Long Island City, NY. Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

Hardwired: Low Voltage Controls – IQ/MLC™


IQ/MLC – Features
Low voltage switching for Standard Motors using a four (4) motor
IQ/MLC™ motor logic controller. Local, group, and master switching,
plus 5 aligned stopping positions.

First National Bank of Hawaii, Honolulu, HI


Kohn Pederson Fox Associates – Architects
IQ/MLC Window Management System
™ Gensler – Interiors

User Defined Mid-Window Alignment with “Normal” Mode and “UniformMode™”.

Intermediate stop positions Master, group and individual switching


Mid-window alignment, 5 positions: full up, full down plus With four local switch ports, plus two master ports, control any
3 intermediate stops defaulting to 25%, 50% and 75%, or combination of the four motors attached to an IQ/MLC to cre-
programmable to align with architectural features. Shade ate multiple levels of control for Sub-Group, Group and Master
band alignment at each mid-window stop position. Assured Switching. Daisy chain local and/or master switch ports of two
alignment can be maintained across multiple shades to or more IQ/MLC’s to form large groups or networks of motors.
each mid-window position.
Motor/switch assignment flexibility to control each
A/V, Home Theatre and PC of 4 local switch inputs
Optional RS-232/485 interface, or third party dry contact DIP switches conveniently configure each local switch (4)
closures for integrated control. to any combination of the four internal motors in order to
orchestrate individual and group motor control. Reconfigure
Two (2) Operational Modes switching zones without rewiring.
UniformMode™:
Shades may only be stopped at up; down or one of the Optional Remote Control
three intermediate stop positions assuring modular Use wireless remotes to control the IQ directly or through
uniformity for the project. an A/V or Lighting System interface.

Normal Mode:
Shades may be stopped at the full up, full down, the three Note: With the IQ/MLC™ some motors can be in the
intermediate stop positions or any where in between. “Normal Mode” while others are in the “UniformMode™”
.

Continued ☞
MechoShade Systems, Inc.
42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.23
MS2200 - 6/1/04

© Copyright 2004 MechoShade Systems, Inc., Long Island City, NY. MechoShade and ElectroShade are registered trademarks of, and IQ/MLC, “UniformMode” and Modular Alignment are trademarks of, MechoShade Systems,
Inc. Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

Hardwired: Low Voltage Controls – IQ/MLC™


IQ/MLC™ – Features
IQ/MLC™ – Motor/Switch Assignments Switch Operation
DIP switches define the switching relationship between the four Tap the appropriate combination of
internally controlled motors on each of the four local switches. buttons on any one of the Local or
Master Switches and all the shades
To assign a specific motor to a local switch input move
assigned to that switch will align at
the appropriate DIP switch to the “ON” position. When all DIP
either of 5 positions shown below:
Switch positions are finialized, push twice to RESET button.

TAP
1 Full Up

M-1 M-2 M-3 M-4 L$1 L$2


A1 A2 A3 A4 A5 A6 A7 A8
Disconnect
Plug
ON TAP
OFF
115 VAC
(230 VAC)
M1 M2 M3 M4 M1 M2 M3 M4 1+2 25% or
Junction
J J J
Box
J
ON
B1 B2 B3 B4 B5 B6 B7 B8 Custom
OFF
M1 M2 M3 M4 M1 M2 M3 M4
Set Point
L$3 L$4 One

L$#1 L$2
ON OFF

A ON
OFF
A1

M1
A2

M2
A3

M3
A4

M4
A5

M1
A6

M2
A7

M3
A8

M4
MOTOR/SWITCH TAP
ASSIGNMENT
ON
OFF
B1

M1
B2

M2
B3

M3
B4

M4
B5

M1
B6

M2
B7

M3
B8

M4
DIP SWITCHES
2 50% or
Custom
L$3 L$4

OFF ON

Set Point
Two
LS LS LS LS MS MS
(L)
1 2 3 4 1 2
4 or 6
conductor 12 VDC 12 VDC
TAP
115V
MS PORT TO NEXT
2+3 75% or
(230V 50/60 Cycle) IQ/MLC &/OR
SWITCH Custom
Set Point
L$ 1 L$ 4 M$ 1 Three
M #1, 2 ,3 M #3, 4 M #1-4

Local Master
Switches Switch
TAP
4 Conductor 26 Gauge Modular Plug 6 Conductor 26 Gauge Modular Plug 3 Full
LS Local Switch MS Master Switch 1 Motor Number
Down

In this scenario Local Switch #1 controls Motors 1, 2 and 3.


Local Switch #4 controls motors 3 and 4. The Master Switch controls all.
Switches #1 and #3 have no control function.

Continued ☞
MechoShade Systems, Inc.
42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.24
MS2200 - 6/1/04

© Copyright 2004, MechoShade Systems, Inc., Long Island City, NY. MechoShade and ElectroShade are registered trademarks of, and IQ/MLC is a trademark of, MechoShade Systems, Inc.
Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

Hardwired: Low Voltage Controls – IQ/MLC™


IQ/MLC – Applications
Orchestrating Large Master Groups
KEY:
1 2 3 4 5 6 7 8
M M M M M M M M Motor/Switch Assignments
(16 Dip Switches, 4 per
J J J J J J J J local switch)

A B Local Switches
A 1-4, B 5-8
M M M M
Group Switches
A and B
Max is 10 IQ/MLC’s on a single switch input.
Master Switch A/B
Master with approved
A/B
"T" connector

WARNING: SPLICES IN CONTROL LINE!


Use only approved modular cable type "T" connectors
mounted to back of switch.

Local Switches cannot be ganged to control motors


on two (2) IQ/MLC units.

Orchestrating Large Groups with Multi-Level Control


1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 KEY:
M M M M M M M M M M M M M M M M

Motor/Switch Assignments
J J J J J J J J J J J J J J J J (16 Dip Switches, 4 per
Local switch, one for each
A B C D motor)
M M M M M M M M
Local Switches
A 1-4, B 5-8, C 9-12,
L$ L$ L$ L$
1 2 3 4
L$ L$ L$ L$
5 6 7 8
L$ L$ L$ L$
9 10 11 12
L$ L$ L$ L$
13 14 15 16
D 13-16
A B C D Group Switches
A, B, C, D with
Sub Group Control
M M
M M
S S
Master Switches
A/B/C/D

M M IQ Sub Group Controller


Master Master
M M (SGC)for up to
S S TM

A/B/C/D A/B/C/D 4 IQ/MLC units


Max is 10 IQ/MLC’s on a single switch input.
For more complex configurations and higher level of control see the I•CON.

MechoShade Systems, Inc.


42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.25
MS2200 - 6/1/04

© Copyright 2004, MechoShade Systems, Inc., Long Island City, NY. MechoShade and ElectroShade are registered trademarks of, and is a trademark of, MechoShade Systems, Inc.
Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

Hardwired: Low Voltage Controls – IQ/MLC™


Low voltage switching for standard motors using a four (4) motor IQ/MLC™ motor logic controller.

J-BOX LEAD
MOTOR LEAD –5’0" 115 VAC (230 VAC)
MAXIMUM WIRE SIZE = AWG#12
– 1’0" PRE-WIRED MOTOR #2 3 MOTOR #3
TO MOTOR (M2) (MOTOR 1 THRU MOTOR 4 & POWER) (M3)

BLACK Note:
WHITE The black and red motor lead
MOTOR #1 JUNCTION JUNCTION MOTOR #4
1 (M1) BOX wiring shown is for Direction 1:
BOX (M4)
- Right-Hand Drive Regular-Roll
- Left-Hand Drive Reverse-Roll
GREEN (GROUND)

BLACK (DIRECTION 2)
WHITE (NEUTRAL)
RED (DIRECTION 1)

2 Reverse the black and red motor


lead wiring for Direction 2:
GREEN JUNCTION
JUNCTION - Left-Hand Drive Regular-Roll C US
DISCONNECT
BOX RED - Right-Hand Drive Reverse-Roll BOX
PLUG Since 1876

See indications below each


motor R & B terminal. 6-Position, 6-Connector Modular Plug Assembly
NOTE: G W R B G W R B G W R B G W R B
1 - INSTALLATION
MUST COMPLY WITH
ALL LOCAL AND
NATIONAL ELECTRICAL MOTOR 1 MOTOR 2 MOTOR 3 MOTOR 4 (Cable is turned
prior to crimping to
CODES FOR 120 VAC 123456 2nd modular plug) 123456

(230 VAC) AND LOW DIP SWITCHES ARE FACTORY SET TO "OFF," BK GR BL BK GR BL
WH RD YW WH RD YW
VOLTAGE WIRING MOTORS WILL NOT OPERATE UNLESS THE ASSIGNED DIP SWITCHES
REQUIREMENTS FOR EACH LOCAL SWITCH ARE TURNED "ON" POLARITY REQUIREMENTS
F5
2 - MAXIMUM LOW LOCAL MOTOR/SWITCH ASSIGNMENT DIP SWITCHES
FOR MODULAR CABLE
VOLTAGE MODULAR L$1: #A1-A4 TO ENSURE PROPER SWITCH
A1 A2 A3 A4 A5 A6 A7 A8
CABLE IS 400 FEET F4 L$2: #A5-A8 ON CONNECTIONS, WE HIGHLY RECOMMEND
CUMULATIVE Motors: M1-M4 OFF THE USE OF AN AMP CRIMPING TOOL
M1 M2 M3 M4 M1 M2 M3 M4
(P/N ETCO 16520BU). CRIMPS ARE
L$3: #B1-B4 B1 B2 B3 B4 B5 B6 B7 B8 MADE THE SAME WAY ON BOTH ENDS -
IQ/MLC POWER L$4: #B5-B8 ON
REQUIREMENT: OFF
NOT OPPOSITE LIKE TELEPHONE
Motors: M1-M4 CONNECTORS.
M1 M2 M3 M4 M1 M2 M3 M4
INPUT
FUSES
LINE VOLTAGE INPUT:
115 VAC, 60 HZ, 10% MOTOR LEAD
220 VAC, 50/60 HZ, 10% F3 –1’0" (30CM) LONG
PRE-WIRED
LOW VOLTAGE INPUT: RESET POWER LED
MASTER SWITCH TO MOTOR
12 VDC, 8MA F2 LOCAL SWITCH PORTS PORTS
1 2
OUTPUT:
120 VAC, 60 HZ,
F1 1 2 3 4 1 2 DISCONNECT
3.8 AMPS PER PLUG
12 VDC
OUTPUT/MOTOR 6
HOT 4- OR 6-
230 VAC, 50/60 HZ CONDUCTOR 4/6 4/6 4/6 4/6 6 2 3
NEUTRAL
1.9 AMPS PER FLAT 26 GA 12 VDC,
6 - CONDUCTOR J-BOX LEAD
OUTPUT/MOTOR GROUND MODULAR
FLAT 26 GA –5’0" (152CM)
POWER SOURCE CABLE LONG
FUSES (MOTOR): F2, F3, F4, F5 MODULAR CABLE
115 VAC-20A
10 AMP PER 120V MOTOR L$1 L$2 L$3 L$4 M$1
MASTER
4 AMP PER 230V MOTOR LOCAL LOCAL LOCAL LOCAL PLUS LOW VOLTAGE
(PLUS LOW VOLTAGE OPTION) OPTION
FUSES CONTOLLER: F1
1 AMP NOTE: SEE REVERSE SIDE FOR POLARITY REQUIREMENTS OF FLAT MODULAR CABLE

Note:
Drawings are incomplete unless both pages of this Wiring Diagram, 4.26 – 4.27,
plus the Electrical Notes pages 4.49 – 4.51 are included.
Continued ☞
MechoShade Systems, Inc.
42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.26
MS2200 - 6/1/04

© Copyright 2004, MechoShade Systems, Inc., Long Island City, NY. MechoShade and ElectroShade are registered trademarks of, and IQ/MLC is a trademark of, MechoShade Systems, Inc.
Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

Hardwired: Low Voltage Controls – IQ/MLC™


How to connect two or more (4) motor IQ/MLC™’s, with five or more standard motors.

TO MOTORS 115 VAC


(230 VAC)
B G W R B G W R B G W R B G W R B G W R B G W R B

MOTOR 3 MOTOR 4 MOTOR 5 MOTOR 6 MOTOR 7 MOTOR 8

F5
CAL MOTOR/SWITCH ASSIGNMENT DIP SWITCHES LOCAL MOTOR/SWITCH ASSIGNMENT DIP SWITCHES
: #A1-A4 A1 A2 A3 A4 A5 A6 A7 A8 L$5: #A1-A4 A1 A2 A3 A4 A5 A6 A7 A8
F4
: #A5-A8 ON L$6 #A5-A8 ON
ors: M1-M4 OFF Motors: M5-M8 OFF
M1 M2 M3 M4 M1 M2 M3 M4 M1 M2 M3 M4 M1 M2 M3 M4

: #B1-B4 B1 B2 B3 B4 B5 B6 B7 B8 L$7: #B1-B4 B1 B2 B3 B4 B5 B6 B7 B8


: #B5-B8 ON L$8: #B5-B8 ON
OFF OFF
ors: M1-M4 Motors: M5-M8
M1 M2 M3 M4 M1 M2 M3 M4 M1 M2 M3 M4 M1 M2 M3 M4

FUSES

F3
MASTER SWITCH MASTER SWITCH
OCAL SWITCH PORTS PORTS F2 LOCAL SWITCH PORTS PORTS

2 3 4 1 2 F1 5 6 7 8 1 2
12 VDC
6 6
HOT 4- OR 6-
4/6 4/6 4/6 6 CONDUCTOR 4/6 4/6 4/6 4/6 6
12 VDC, NEUTRAL
FLAT 26 GA 12 VDC,
6 - CONDUCTOR GROUND MODULAR 6 - CONDUCTOR
FLAT 26 GA POWER SOURCE CABLE FLAT 26 GA
MODULAR CABLE 115 VAC-20A MODULAR CABLE
1 L$2 L$3 M$1 L$5 L$6 L$7 L$8
LINK VIA
AL LOCAL LOCAL MASTER LOCAL LOCAL LOCAL LOCAL
CONTROLS LINK VIA CONNECTION CONNECTION
(PLUS
ALL IQ/MLC S TO THE NEXT IQ/MLC SUB GROUP TO THE NEXT
LOW VOLTAGE
AND MOTORS MASTER PORT #1 CONTROLLER IQ/MLC MASTER
OPTION)
ON CIRCUIT P/N: IQML SGC6 RJ BD
PORT #1

M M MAXIMUM OF 12
OPTIONAL
M M WARNING: SPLICES IN CONTROL LINE! IQ/MLC CONTROL
ELECTRICAL TERMINATION
USE ONLY MODULAR CABLE TYPE T CONNECTORS UNITS ON A
S S
JUNCTION BOX MOUNTED TO BACK OF SWITCH. MASTER CIRCUIT
(BY OTHERS)
WITH UP TO 4
OPTIONAL PLUG-IN
RECEPTACLE WARNING: SUB-GROUP CONTROLLERS! LOCAL SWITCHES
DISCONNECT
PLUG
USE FOR ISOLATION WHEN ORCHESTRATING PER IQ/MLC.
MOTOR MULTI-LEVEL GROUPS BETWEEN IQ/MLCs. WE
LEAD
RECOMMEND THAT YOU CONTACT MECHOSHADE
MASTER
SYSTEMS CUSTOMER SERVICE FOR SPECIFIC
2 1 PLUS LOW
VOLTAGE INSTRUCTIONS/WIRING DIAGRAMS.
M$2
OPTION
MASTER

Note:
Drawings are incomplete unless both pages of this Wiring Diagram, 4.26 – 4.27,
plus the Electrical Notes pages 4.49 – 4.51 are included.

MechoShade Systems, Inc.


42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.27
MS2200 - 6/1/04

© Copyright 2004, MechoShade Systems, Inc., Long Island City, NY. MechoShade and ElectroShade are registered trademarks of, and IQ/MLC is a trademark of, MechoShade Systems, Inc.
Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

Hardwired: Low Voltage Controls – IQ/MLC™


IQ/MLC Applications

IQ/MLC with standard motors for single and multibanded shades


TM

GROUP A WITH AUTO INTERMEDIATE STOP POSITIONS AT THE TOUCH OF A BUTTON (PLUS MASTER CONTROL OF GROUPS A & B)

1 1 2 3 1 1 2 3

M1 M 2 M3 M 4 Alternate for
RS-232 Interface
J J J J
115V 115V 115V 115V
IQ/MLC A
115 VAC M M
(230 VAC)
IQ/MLC A RS-232
12 V

A/V System
M M M1-4 RS-232 Interface
115 VAC
(230 VAC) 12 V 12 V
Dry Contact A/V System
LOCAL Closures M1-4 12V

L$1 LOCAL
M1-2 L$2 MASTER A
Standard Configuration M3-4 M1-4 L$1 L$2 MASTER
RS-232 (alternate) M1-2 M3-4 M1-4

LOCAL & MASTER a) Local Switch L$1 controls motors 1 & 2 via internal dip switches. M M M

CONTROL b) Local Switch L$2 controls motors 3 & 4 via internal dip switches.
With auto-set intermediate c) A/V System, with a dry contact or RS-232 interface, controls motors 1-4. Assured Alignment
stop positions for assured
alignment. d) Master Switch A controls motors 1-4.

GROUP A (PLUS MASTER CONTROL OF GROUPS A & B) GROUP B (PLUS MASTER CONTROL OF GROUPS A & B)

1 1 2 3 1 1 2 3 1 1 2 3 1

M1 M 2 M3 M 4 M 5 M6 M7

J J J J J J J
115V 115V 115V 115V 115V 115V 115V
Movable
Partition
M1-4 or future M5-8
IQ/MLC A wall
IQ/MLC B
M M M M
115 VAC 115 VAC
12 V (230 VAC) 12 V
(230 VAC) 12 V
L$1 12 V RS-485
LOCAL M1-4 SGC 12 V
A/V System 12 V LOCAL
M1-7 12V
Standard Configuration L$5
MASTER A RS-485 Interface M5-8 MASTER B
RS-485 (alternate) M1-8
RS-485
M1-8
RS-485

a) Local Switch L$1 on IQMLC A controls motors 1-4 via internal dip switches.
M M M

LOCAL & MASTER


CONTROL b) Local Switch L$5 on IQ/MLC B controls motors 5-8 via internal dip switches.
With auto-set intermediate c) A/V System, with a dry contact or RS-485 interface, controls motors 1-7. Assured Alignment
stop positions for assured
alignment. d) Master Switches A & B control motors 1-7.

MechoShade Systems, Inc.


42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.28
MS2200 - 6/1/04

© Copyright 2004, MechoShade Systems, Inc., Long Island City, NY. MechoShade and ElectroShade are registered trademarks of, and MLC is a trademark of, MechoShade Systems, Inc.
Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

Hardwired: Low Voltage Controls – IQ/MLC™


IQ/MLC™ – Features
IQ/MLC™ – Switch Management
4 zones – Each motor control zone is associated with a local
switch port (L$1, L$2, L$3 and L$4)

Each local switch port may control any combination


of 4 motors through the DIP Switch settings.

Example of IQ/MLC Dip Switch Assignments

Dip Switch # A1 A2 A3 A4 A5 A6 A7 A8
ON
Dip Switch Row A
OFF
MOTOR # M1 M2 M3 M4 M1 M2 M3 M4

Controls Motor 1 Controls Motor 2


IQ/MLC A and Motor 3
A B
M M

Dip Switch # B1 B2 B3 B4 B5 B6 B7 B8
ON
Dip Switch Row B
OFF
MOTOR # M1 M2 M3 M4 M1 M2 M3 M4
Result:
Overlapping zones Controls Motor 3 Controls Motor 4
and Motor 4
as required.

Low Voltage Interface for A/V Control:


Connect local or master switch ports to the optional IQ/MLC™
RS-232/485 interface or third party dry contact closures.
Three dry contact closure terminals are required for full
operation of IQ/MLC. Two dry contact closures for 17 18 19 20
M M M M
up/down operation only.

J J J J

E
M M
Dry contact
low voltage
interface
L$ L$ L$ controls all
18 19 20 4 motors
SR Master
E
LECTURN
(controls motors 17 & 18)

MechoShade Systems, Inc.


42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.29
MS2200 - 6/1/04

© Copyright 2004, MechoShade Systems, Inc., Long Island City, NY. MechoShade and ElectroShade are registered trademarks of, and IQ/MLC is a trademark of, MechoShade Systems, Inc.
Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

Hardwired: Low Voltage Controls – IQ/MLC™


For A/V and Dimming Control Systems Integration with
Building Management Systems • Smart Homes • Home Theatre • Conference Rooms

IQ/MLC™ Window Management System for ElectroShades®


using Dry Contact Closures
If UP, DOWN and 3 INTERMEDIATE Stop Positions If only UP and DOWN positions are required:
are required: • Provide two (2) low voltage, 12 VDC, 10mA momentary
• Provide three (3) low voltage, 12 VDC, 10mA momentary dry contacts, A (UP), B (DOWN).
dry contacts, A (UP), B (MID POINT) and C (DOWN). • To stop the shade while traveling; pulse either
• To move the shades DOWN requires a momentary pulse contact.
of Contact C. • To activate UP or DOWN, pulse either contact.
• To move the shades UP requires a momentary pulse of
Contact A.
• To stop the shades while traveling, pulse either
contacts A, B or C.
• To move the shades to Position 1 (25% down).
Requires a momentary pulse of Contact A & B.
• To move the shades to Position 2 (50% down).
Requires a momentary pulse of Contact B.
• To move the shades to Position 3 (75% down)
Requires a momentary pulse of Contact B & C.
• Recommended momentary pulse length between
100 and 500 milliseconds.

Continued ☞
MechoShade Systems, Inc.
42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.30
MS2200 - 6/1/04

© Copyright 2004, MechoShade Systems, Inc., Long Island City, NY. MechoShade and ElectroShade are registered trademarks of, and IQ/MLCand MLC are trademarks of, MechoShade Systems, Inc.
Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

Hardwired: Low Voltage Controls – IQ/MLC™


For A/V and Dimming Control Systems applications for
Building Management Systems • Smart Homes • Home Theatre

IQ/MLC™ Window Management System for ElectroShades®


using an RS-232/485 Interface
For control of a single IQ/MLC via RS-232: For control of multiple IQ/MLC’s via RS-485:
• Use optional IQ/MLC RS-232 Interface EMLC 0232 RS MO. • Use optional IQ/MLC RS-485 Interface EMLC 0485 RS MO.
• Connect the A/V System to the Communications Port on • Follow the same procedure above for Master Ports and
the RS-232 Interface using a modular cable connection. connect the Local Switches connect directly to the IQ/MLC
• Connect the IQ/MLC Local Switch Ports #1-4 to Local as per the standard wiring diagram.
Switches via the IN and OUT Ports #1-4 on the RS • Multiple IQ/MLC’s can be connected to a single Master Port
Interface. Either IQ/MLC Master Switch Port can connect on the RS Interface via approved modular T or Y connectors.
to a Master Switch via IN and OUT Ports #5 on the RS • RS-485 Interfaces may be daisy chained together to form
Interface larger networks via the IN and OUT Communications Ports
• For POWER connect the RS-232 Interface to the IQ/MLC. on the RS Interface.

115 VAC M M
(230 VAC)
12 V
RS-232
A/V System
M1-4 RS-232 Interface

12 V
12V

LOCAL MASTER

M1-4 M5-8
115 VAC A 115 VAC B
(230 VAC) (230 VAC)
M M M M
12 V 12 V

LOCAL 12 V LOCAL

MASTER MASTER
A/V System A 12 V B
M1-7
MM
RS-485 MM
S S

12V 12 V

RS-485 Interface
RS-485

Continued ☞
MechoShade Systems, Inc.
42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.31
MS2200 - 6/1/04

© Copyright 2004, MechoShade Systems, Inc., Long Island City, NY. MechoShade and ElectroShade are registered trademarks of, and IQ/MLC, MLC and I•CON are trademarks of, MechoShade Systems, Inc.
Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

Hardwired: Low Voltage Controls – IQ/MLC™


IQ/MLC Component Specifications
The IQ/MLC™ System consists of:
IQ/MLC Four Motor Logic Controller:
Low voltage four (4) motor controller for standard motors with
local and master switch control capability. Dip switch assign
motor switch assignments to form groups. Any of the four local
switches can control any combination of the four motors
connected to the IQ/MLC. Provides full up, full down and three
intermediate and custom stop positions at the touch of a
button for assured alignment. Additional IQ/MLCs can be wired
in parallel or series. 17 VDC, 0.1A max per switch contact.
Input: 120 VAC, 0.5A max; 240 VAC 0.25A max.
__ __
Output: 120 VAC, 3.8A max; 240 VAC, 1.9A max. __ __
P/N: 120V: IMLC 120V ST SP; 230V: IMLC 230V ST SP.
IQ/MLC Switch:
3-button single low voltage intelligent switch for local or master
control provides full up, full down and three intermediate and
custom stop positions at the touch of a button. Allows the user
to calibrate the IQ/MLC and select between uniform and
normal modes. Also available in 6-button zone double switch.
(12V, 100 mA, max).
P/N: 3-Button: ESWX IQ03 _ _ _ _ ;
6-Button: ESWX IQ06 _ _ _ _ .
__ __
Optional Remote Control:
Full Up/Down operation in Normal Mode, or intermediate stop Modular Y Adapter: Two 6-position / 6-contact female
positions in the UniformMode™. modular jacks with UTP cable. P/N: YADP 6POS 6C 2F
Accessory Controls (ACC): Modular Cable Coupler: 6-position, one to one wiring pattern.
Optional external inputs for security, life-safety, audio/visual P/N: COUP 5050 AM P1
and other applications. For example, Sun Activated Sensors,
Modular Plug: 6-position, 6-contact RJ-12 plug.
Seven-Day Timers or MechoShade’s AAC SolarTrac™
P/N: RJ12 6CON 6P PL
computerized green-building management system.
Cable Tester: Siemon STM-8. P/N: ECAT SIEM STM8
IQ/MLC Accessory Interface: Interface for connecting
SACs and Timers. 120V: ESSA IQ115 STSP, Crimping Tool: Modular plugs are UL approved when
230V: ESSA IQ230 STSP terminated using this tool and procedures outlined in
IS 408-9767. P/N: ETCO 1652 O8 UL
Modular Cable: 26 gauge, 6-conductor flat modular cable
(stranded wire) available as uncrimped rolls or pre-crimped Sub Group Controller: Six 6-position / 6-contact female
lengths. modular jacks for connecting up to 4 I•CON controllers.
P/N: IQML SGC6 RJ BD
Un-Crimped, 500 foot (16.6m) roll: ESMC 0302 VL BE
Un-Crimped,1,000 foot (333.3m) roll: ESMC 0340 VL GR IQ/MLC RS232 &485: RS485 protocol with a PC requires a
Pre-Crimped, 2 feet (.6m) long: ESMC 0341 VL BE 485 PC card or an IQ/MLC RS232 or 485 Adapter. Up to 5
Pre-Crimped, 7 feet (2.3m) long: ESMC 0278 VL BE zones per interface adapter, up to 12 IQ/MLC units per zone.
Pre-Crimped, 25 feet (8.3m) long: ESMC 0313 VL BE Allows a total of 60 control units per interface.
Pre-Crimped, 50 feet (16.6m) long: ESMC 0343 VL BE
RS232: P/N: EMLC 0232 RS MO (PC to 1st interface)
Modular T Adapter: Two 6-position / 6-contact female modular RS485: P/N: EMLC 0485 RS MO (interface 2 and up)
jacks with UTP cable. P/N: MODU 6POS 6C 2F

MechoShade Systems, Inc.


42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.32
MS2200 - 6/1/04

© Copyright 2004, MechoShade Systems, Inc., Long Island City, NY. MechoShade and ElectroShade are registered trademarks of, and IQ/MLC and UniformMode are trademarks of MechoShade Systems, Inc.
Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

ElectroShade® Optional Low Voltage Control Accessories

Remote Control (Specify IR or RF)


MechoShade® offers a Remote Control line that provides
motor control from a distance through the use of a hand
held radio transmitter. Remote Controls are available as
one, two, three or four motor controllers.

IQ/MLC™ utilizes IR remote only.


P/N: Single Channel: EIRC 1014 RA TR Single Four
Four Channel: EIRC 1015 RA TR Channel Channel

24-Hour Digital Timer


MechoShade offers a compact dual direction digital timer
for carefree automatic control for ElectroShades. The 24-
Hour Timer is easy to install and simple to program and
will raise and lower your shades at different times of the
day. Protecting the interior from solar impact.

IQ/MLC requires the SAC/TIMER Interface.


P/N: EDTI 0351 24 WH
EDTI 0352 24 CW
IQ/MLC SAC/Timer Interface:
120V P/N: ESSA IQ115 STSP
230V P/N: ESSA IQ230 STSP

Solar Activated Controllers (K-Lux)


MechoShade offers a line of Solar Activated Controllers
(SACs) with sensors that continually monitor the solar
brightness, triggering the control unit to extend or retract
the shade. SACs are available for use with a single motor
3-motor Individual-Group Controllers (IGC), four motor
IQ/MLC’s and MLC four motor controllers.

IQ/MLC requires the SAC/TIMER Interface.


SAC with Photo Cell, Flush Mount, Single Motor:
P/N: ESSA 0901 ST WH • ESSA 0931 ST CW
SAC with Photo Cell and Switch:
P/N: ESSA 0897 ST WH • ESSA 0927 ST CW
IQ/MLC SAC/Timer Interface:
120V P/N: ESSA IQ115 STSP
230V P/N: ESSA IQ230 STSP
Photo Cell Only:
P/N: ESPC 0313 PL WH
Continued ☞
MechoShade Systems, Inc.
42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.33
MS2200 - 6/1/04

© Copyright 2004, MechoShade Systems, Inc., Long Island City, NY. MechoShade and ElectroShade are registered trademarks of, and IMCS, IQ/MLC, MLC and AAC SolarTrac are trademarks of MechoShade Systems, Inc.
Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

ElectroShade® Optional Low Voltage Control Accessories

Digital Key Pad


The “Keyless” programmable indoor security switch. Prevent
unwarranted operation of shades with your personal code
number through the Digital Key Pad. The four digit private
entry code can be changed by the user to ensure limited
access, or protection.

NOTE: Compatible with MLC™ and I•CON™ standard motor control


systems. IQ/MLC™ and I•CON Intelligent Motor Control System for
full up/down operation only.

P/N: ESDX 0739 IN WH

Key Switches
MechoShade offers a line of high-security Indoor Key switches.
They are available as:
• Light duty & heavy duty designs
• White or ivory cover plates
• Maintained or momentary switches

NOTE: Compatible with MLC and I•CON standard motor control systems.
Momentary Switches compatible with Intelligent Motor Control System
for full up/down operation only.

Maintained P/N: ESWX RYMA PS CW


Momentary P/N: ESWX RYMO PS CW

Miscellanous Switches Décor & Paddle


Switchplates

Line or Low Voltage IQ/MLC Standard Switches

MechoShade Systems, Inc.


42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.34
MS2200 - 6/1/04

© Copyright 2004, MechoShade Systems, Inc., Long Island City, NY. MechoShade and ElectroShade are registered trademarks of, and IMCS, IQ/MLC, I•CON, MLC and AAC SolarTrac are trademarks of MechoShade Systems,
Inc. Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

Networked: Low Voltage Controls – I•CON™


I•CON
Addressable Local and Wide Zone Switching on a bus.
Location Number
0016 Table Value

ISBI LEFT RIGHT LZ/DSA WZA LZA LOCATION

I•CON 1 2 3
SERVICE

POLL

Hand-Held C US
LOCATION
4 5 6 LZ/DSA

UNIFORM WZA
7 8 9 LZA

Programmer SHIFT
WINK

0
SEND

PROG
LEFT

RIGHT Since 1876

Low Voltage I•CON Low Voltage Low Voltage


Busline Bus Interface Busline Busline

BS I•CON
Local Switch I•CON
I•CON
I•CON I•CON Intelligent
Intelligent
Bus Supply/ Standard Switch
REPEATER Switch BI 76543210 76543210

BI 76543210 76543210
Switch

I•CON
Intelligent
Switch

The fully addressable MechoShade’s® Intelligent Motor Control • Multi-Level Overlapping Control (individual / group / master
System™ (I•CON™) is a 2-way communicating software control)
busline control system that is ideal for medium, large and - Each motor can be part of up to 9 different control groups.
complex networks. The major advantages of the I•CON system - Simplified wiring: communication network requires only 1
are wiring simplicity, exceptional flexibility and lower installation connection per controller regardless of how many control
costs, making I•CON the ideal solution for base building and groups are implimented.
multitenant Class A office building projects where floor layouts • Open architecture allows access via dry-contact control.
frequently change. Also, Audio/ Visual centers and/or conference
• Local control network enables cost effective local control
rooms with movable walls resulting constant changes in
through dry contact inputs without separate device.
shade configuration.
- Integrates controllers with 3rd party controllers without
adding components.
The I•CON features: - Allows 3rd party switches to control shades while keeping
• Expandable/Scalable system employs 2-way, low voltage a consistent user interface with lights and other systems.
communication network capable of building-wide applications.
• Six (6) Alignment Positions.
M
• “Out -Of-The-Box” configuration.
- Four (4) programmable mid-window
• Free Topology wiring allows low voltage connections to be 20%
alignment positions which default to
run in the most cost-efficient manner (daisy-chain, star/home 20% / 40% / 60% / 80%. 40%
run, loop, etc.). 60%
• Two Modes of Shade Operation:
• Two forms of addressing – DIP Switch or software Normal and UniformMode™. 80%
• Program/Re-program Motor grouping without rewiring or • Integrates with Lighting, HVAC, A/V
Auto Set Positions
“Climbing the ladder”. and BMS.
- DIP switch addressing available for installation
- Dry contact integration through local control network
without manual programming tools or PC.
- LonWorks integration through communications network
- Handheld Programmer enables convenient
- AAC/PC for building-wide SolarTrac Applications
programming of motor groups from 1 location
without accessing each controller.

Continued ☞
MechoShade Systems, Inc.
42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.35
MS2200 - 6/1/04

© 2004, MechoShade Systems, Inc., Long Island City, NY. I•CON and UniformMode are Trademarks of MechoShade Systems, Inc.. Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

Networked: Low Voltage Controls – I•CON™


I•CON

Multi-Level Control provide flexibility for changes and modifications in the field
The I•CON Control System consists of standard, open source without reprogramming, while maintaining the key features
line voltage motors connected to addressable, 2-motor I•CON of the I•CON system.
Bus Interface Controllers (BI).
The I•CON Local Switch and Local Switch Port have the
• Each I•CON network can support 255 unique addresses.
following features/functionality:
• If more than 255 addresses are required, the network
• I•CON Local Switches plug into one of 2 port on a BI,
can be extended.
and directly control one of the corresponding motors
• Through the BI each motor can respond to up to 9-unique
without any addressing or programming
addresses thus enabling a motor to be part of 8 different
• The I•CON Local Switch's control can be expanded to
group addresses and yet still be individually addressed.
control other motors on the network by setting a DIP
• Control wiring is simple, flexible and independent of
switch address on the Local Switch Port that the I•CON
addressing scheme unlike hardwired systems.
Local Switch is connected to.
• Control wiring links every BI together into the network
• Any motor on the network with an address that
using 2 twisted pair, low voltage cabling or standard
corresponds with the DIP switch address will respond
CAT5 cabling.
to the Local Switch.
• Control network wiring is a free topology.
• Preset DIP Switch Addressing provides out of the box
Addressing group control functionality, avoiding field commissioning
Within the I•CON BI each motor can be addressed and and programming.
controlled through up to 9 different addresses: • The I•CON Local Switch provides 6 alignment positions,
1) 8 - Software Programmable Network Addresses including full up, full down and 4 default intermediate
2) 1 - Local Port DIP Switch Address (DSA) positions of 20%, 40%, 60% and 80%
Devices on the network (ie. Intelligent Switches) can control a • Up to 4, custom intermediate alignment positions can
motor through any one of its internal 9 addresses. Devices on be easily be set by the user or installer.
a BI's Local Port can control the motor they are directly wired
Network Addressing – Intelligent Switch Control
to plus any motors which have a Programmable or DSA
I•CON Intelligent Switches provide maximum flexibility in
address coinciding with the DIP switch address of the Local
wiring, control and access to the I•CON network. I•CON
Port that the Local Switch is connected to.
Intelligent Switches share the same 4 button architecture as
Local Port Addressing - Local Switch Control: the I•CON Standard Switch, but have additional intelligence
Each I•CON BI has 2 local switch ports - one for each of the built into a circuit board on the back of the switch. I•CON
motors the BI controls. The I•CON Local Switch and Port Intelligent Switch features and functions include:
allows one to pre-set a simple network in the factory, yet Continued ☞

MechoShade Systems, Inc.


42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.36
MS2200 - 6/1/04

© 2004, MechoShade Systems, Inc., Long Island City, NY. I•CON amd UniformMode are Trademarks of MechoShade Systems, Inc.. Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

Networked: Low Voltage Controls – I•CON™


I•CON

• I•CON Intelligent Switches can be wired anywhere on Six Position Mid-Window Alignment
the I•CON network and are not limited to connection to I•CON automatically aligns two or more motorized shades
a BI, providing flexibility, convenience and lower at auto set or custom set positions on a window. Each switch
wiring costs. positions shades to 6 aligned positions. Using a four button
• I•CON Intelligent Switches can control motors any- switch, shades may be positioned and aligned at four
where on the network, regardless of physical location. intermediate set points (20%, 40%, 60% & 80% of the
• A software based address is programmed into an window height or custom programmed at any point on the
I•CON Intelligent Switch: Any motor on the network window as specified by the owner/architect.) Plus full up
with a corresponding address in their address table and full down. Shades always align at the selected stop
can respond to that switch. points top down or bottom up thus compensating for
• Ideal for master control and large or overlapping group variances due to gravity. (See illustration on page 4.38.)
control applications spanning multiple offices or floors.
UniformMode™ and Normal Mode
• Ideal for environments where switches and controls
UniformMode™: Shades may ONLY be stopped at any of the
may require reconfiguration.
6 alignment positions. Normal Mode: Shades may be stopped
• The I•CON Intelligent Switch provides access to the
at any of the 6 alignment positions (Up, 20%, 40%, 60%,80%,
network for a Hand held I•CON programmer which
Down) or anywhere in between.
allows access to any motor/ BI on the network for
programming and commissioning. With I•CON, even though the motors are asynchronous and
• Features an elegant 4-button architecture by which the grouped shades are of different size width and weight,
to access all functions. shade bands can be programmed to align at selected
• Provides 6 alignment positions, including full up, full points on the window.
down and 4 default intermediate positions of 20%,
Third Party Integration
40%, 60% and 80%.
The Local Switch Port extends the integration and operation of
• Up to 4 custom intermediate alignment positions can
the I•CON control network beyond Local Switches to third
be easily be set by the user or installer.
party control systems (Lighting, A/V, HVAC and BMS). The use
• Local Switch Port on the BI allows access to 3rd party
of the dip switch addresses allows the Local Switch Port to
control ie. A/V, Lighting and BMS, via dry contacts.
broadcast the shade commands,
Continued ☞
MechoShade Systems, Inc.
42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.37
MS2200 - 6/1/04

© 2004, MechoShade Systems, Inc., Long Island City, NY. I•CON amd UniformMode are Trademarks of MechoShade Systems, Inc.. Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

Networked: Low Voltage Controls – I•CON™: Features


from a third party system,
throughout the network. Unlike
many competing systems, the
Local Switch Port provides dry
contact integration without requiring
the costly expense of adding an
interface module (ie. dry contact
interface, RS232 Interface). Thus,
the Local Switch Port can provide
a cost effective and universal
method to extend control of the
shading network to other systems
within the building.

I•CON can also utilize a variety of interface modules to Simplicity is the rule and problems due to field wiring errors
integrate with third party control systems through the network are substantially reduced. While net difference in cost is
using RS232, RS485 and a various other protocols and media. minimal (the increased cost of the hardware being offset by
the reduced cost of wiring) the net advantage in operation
Installation
reliability and management flexibility is substantial.
I•CON represents a networked shading control system which
employs a single ubiquitous low voltage cable network to Fully accessible, fully addressable
interconnect controllers (BIs) and switches in order to form and easily programmed / reprogrammed.
control groups Network wiring. Each two motor BI has its own unique four digit location
• Eliminates the labor intensive “spider web” of connections number for ease of locating and programming. Each of the
found in a hardwired system where each switch must two motors are managed by the BI through various
be wired directly to the controller for each motor that address tables. Each side has:
it controls. 1 BI Dip Switch Address (BI/DSA). Manually set.
• Greatly reduces the troubleshooting costs associated 8 Programmable Network Addresses (ISA).
with complex groupings. Set via the hand-held programmer.
I•CON utilizes a free topology network to interconnect The I•CON hand-held Programmer allows access 0016
Location Number Table Value

controllers (BIs), switches, and other network devices. and programming of any BI of Intelligent Switch
ISBI LEFT RIGHT LZ/DSA WZA LZA LOCATION

SERVICE
1 2 3

Whether someone is homerunning cables back out a central


POLL

from any location on the network. Thus the 4 5 6


LOCATION

LZ/DSA

panel or daisy chaining out to each successive devise, I•CON


UNIFORM WZA
7 8 9 LZA

system can be reconfigured without rewiring. SHIFT


WINK

0
SEND

PROG
LEFT

RIGHT

can meet the installation’s requirements to support cost ¤

minimization, quick installation, ease of troubleshooting and/or Switch reconfiguration instead of rewiring
future expansion flexibility. Free topology Each Switch and Bus Interface may be reprogrammed
supports any combination of star, bus on site via the hand-held I•CON Programmer resulting in
and loop wiring structures even within Daisy Chain a system that can be reconfigured without rewiring.
the same installation. This simplifies Additional Switches may be wired in series or in parallel.
installation by allowing the wiring to be Free Topology

run in the most expeditious manner. It


also simplifies expansion by eliminating
restrictions on wiring routing, splicing
and network devise placement. Star

MechoShade Systems, Inc.


42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.38
MS2200 - 6/1/04

© 2004, MechoShade Systems, Inc., Long Island City, NY. I•CON amd UniformMode are Trademarks of MechoShade Systems, Inc.. Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

Networked: Low Voltage Control – I•CON™ Wiring Diagram


Low voltage Standard and Intelligent Switching over a two-way communication busline
for two motors.

I CON I CON I CON

BUS SUPPLY/REPEATER

Note: Drawings are


incomplete unless
both pages of this
Wiring Diagram,
4.39 – 4.40, plus
the Electrical Notes
pages 4.49 – 4.51
are included.

MechoShade Systems, Inc.


42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.39
MS2200 - 6/1/04

© 2004, MechoShade Systems, Inc., Long Island City, NY. I•CON amd UniformMode are Trademarks of MechoShade Systems, Inc.. Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

Networked: Low Voltage Control – I•CON™ Wiring Diagram


How to connect two or more I•CON Bus Interfaces and three or more motors to a bus line.

I CON

I CON

Note: Drawings
are incomplete
BUS SUPPLY/REPEATER unless both
I CON pages of this
Wiring Diagram,
4.39 – 4.40,
plus the Electrical
Notes pages
4.49 – 4.51 are
included.

I CON

I CON

MechoShade Systems, Inc.


42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.40
MS2200 - 6/1/04

© 2004, MechoShade Systems, Inc., Long Island City, NY. I•CON amd UniformMode are Trademarks of MechoShade Systems, Inc.. Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

Wireless Controls – Networked

Burnham Conference Room, San Diego, CA


McCulley Group – Architects

Wireless Controls
MechoShade Systems possesses a line of wireless, radio some fashion from the wireless switch or device controlling it.
frequency (RF) controls. These products offer enhanced The other product solution employs wireless, line voltage
functionality for motorized shades without requiring the wiring (120/240 VAC, 50/60 Hz) 120 VAC M
(240 VAC)
and installation costs associated with low voltage – networked motors. Power is run to the
or low voltage – hardwired controls. The radio frequency signal RTS-equipped motor which
communicates directly between the user interfaces and the communicates directly with
120 VAC (240 VAC)

motors or the controllers actuating the motors without any wireless switches, photosen-
wires. Therefore, aside from wiring line voltage power for the sors, timers, etc. to control the motor’s position. This solution
motors there is no control wiring; thus enabling these products makes wiring power to the motors more efficient since multiple
to offer solutions for retrofit, renovate or new construction motors can be daisychained to a common line voltage
opportunities where installing control cabling behind the power connection.
drywall is not an option.
Flexible and Less Costly to Install
MechoShade’s RTS™ wireless Unlike infrared (IR) wireless technology (like your TV remote
control solutions come in two control), RF wireless technology transmits in an omnidirectional
M

varieties. The first employs manner and therefore does not require the user to “aim” a
wireless, networked control for transmitter at a receiver in order to cause something to
standard, line voltage (120/240 happen. This capability enables the positioning of RF switches
VAC, 50/60 Hz) tubular motors. virtually anywhere in a room without forcing the transmitting
With these solutions power for the motors is run to the RTS- and receiving faces to line up. RF energy also does not
equipped controller where wireless signals from switches and attenuate as quickly as IR thus enabling ranges of over 60
other wireless devices (photosensors, timers, etc.) are received feet in typical installations! Couple this with the fact that RF
to control the distribution and application of power to the motor. technology can transmit through most non-metallic materials
This solution enables the benefits of wireless control with stan- (like drywall) and now the system is capable of controlling
dard, non-proprietary motors. It also has certain wiring advan- motors in more than one room on potentially more than one
tages where the motor being controlled is distant or shielded in floor – without requiring any control wiring!
Continued ☞

MechoShade Systems, Inc.


42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.41
MS2200 - 6/1/04

© 2002, MechoShade Systems, Inc., Long Island City, NY. RTS is a trademark of its respective company. Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

Wireless Controls

Multi-Level Control Groups operation with Lighting controllers, HVAC controllers, A/V
RTS™ wireless solutions provide distributed intelligence to controllers, Security controllers, Life/Fire/Safety controllers or
the system which means that each device or node (motor, more generally into Building Management Systems (BMS). The
controller or user interface) uses a microprocessor to enable methods available for seamless integration of MechoShade’s
it to perform as an active member of the wireless control RTS motors and controllers into these other systems include
network. In order to be part of the network the devices dry contact input and output devices. MechoShade also offers
possess unique addresses. Each motor or controller can a variety of RTS-equipped sensors and timers to provide
be programmed to respond to up to 6 different control groups. automated convenience, comfort and/or energy management
Each control group can enable different levels of motor/shade control enabling RTS to support for example Title 24 or Green
combinations ranging from individual motor control to group/ Building applications. However, the dry contact integration
overlapping group control and finally to master control. Since products also enable third party devices to be employed to
the same motor/shade can be part of any combination of these help supplement these networks.
control groups we refer to its capability as multi-level control.
Safety and Reliability
Advanced Control Logic MechoShade’s RTS product line also offers advanced security
MechoShade’s RTS systems offer one-touch positioning features employing 20 million rolling address codes to prevent
capability where a single momentary button press will cause unauthorized operation into the system and to help prevent
the shade to move directly to a position on the window. Three transmitters from operating unaddressed motors.
alignment points are provided including one mid-window stop
position which is programmable. Thus enabling assured All of MechoShade’s wireless control solutions meet
alignment opportunities with surrounding shades as well – UL325 and CSA 22.2 requirements. Furthermore, the
REGARDLESS OF VARYING WINDOW HEIGHTS. RTS components are further certified by the FCC to
operate at 433.25 MHz.
Seamless Integration
MechoShade’s RTS solutions are designed to be open,
interoperable devices which can work in coordination with
other manufacturers’ controllers or systems to provide
enhanced functionality and features. This can include

Although RF signals can transmit through most walls it does not travel through metal. Therefore, the metallic framing structure of the
building and the furnishings within a room can affect the operational range, can create signal dropout areas and even eliminate the
ability for the system to communicate altogether. In addition, RFsignals from the RTS system and from other systems can interfere
with each other if proper component and system selection has not taken place which can hamper the reliability and functionality
intended within the user’s environment. For many of these reasons hospitals and healthcare facilities typically will not permit the use
of RF systems within their environment. Government facilities and other applications that are concerned about security are also often
resistant to employ wireless solutions.

MechoShade Systems, Inc.


42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.42
MS2200 - 6/1/04

© 2002, MechoShade Systems, Inc., Long Island City, NY. RTS is a trademark of its respective company. Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

Wireless Controls
RTS™ Motors and Controls
Wireless remote direct-to-motor control.

The RTS™ system offers direct-to-motor radio frequency Electrical Specifications


wireless control to any RTS intelligent motor within a 65 foot
Star Head Motor:
range of an RTS equipped switch or remote.
115 Volts 60 HZ 2.1 Amps 240 Watts Maximum
Features: 230 Volts 50/60 Hz. 1 Amp 240 Watts Maximum

• An integrated system of new wireless RF controllers including RTS hand-held RF transmitter:


the RTS hand-held transmitter and RTS wall switch. 3V Lithium battery, type CR 2430

• Eliminates the need for wires between switch and motors. RTS RF Wall Switch:
3V Lithium battery, type CR 2430
• The RTS tubular motor, with built in antenna features user
programmable top and bottom limit switches, can memorize Operating frequency: 433.42 MHz, and has a range of
up to 12 transmitters, one (1) intermediate stop position and 90 ft. (30m) in open space and 65 ft. (20m) through two
is controlled by a special radio frequency which prevents concrete walls.
3
interference from other systems. 2
M
M 4
• With the RTS four channel hand-held transmitter or RTS M
1
wireless wall switch you can program individual, group and M
master control so that with the touch of a button you can 1 2 3 4
control all the shades in the room or on the entire floor
(within the range).

• For greater security the RTS control points are equipped


with 16 million rolling codes which dramatically reduce
interference. You can also choose and change the position
of the control point according to your needs.

• The RTS system not only provides the ease and convenience
of a remote, but also eliminates the need for long wire
runs to connect switches or the need for accessibility to
a control unit. 5
All
• The RTS motors can be wired in parallel.

* RF control should be evaluated for acceptability in Healthcare, government,


airport and/or other facilities where RF signals may interfere with life critical
operating systems. Continued ☞
MechoShade Systems, Inc.
42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.43
MS2200 - 6/1/04

© Copyright 2004, MechoShade Systems, Inc., Long Island City, NY. MechoShade and ElectroShade are registered trademarks of, and IMCS, IQ/MLC, MLC and AAC SolarTrac are trademarks of MechoShade Systems, Inc.
RTS is a trademark of its respective company. Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

Wireless Controls
Standard Motor RTS™ Control System

RTS single motor


controller/receiver

The RTS™ Single Motor Controller provides remote control of Electrical Specifications
any standard motor within a 65 foot range of an RTS-equipped
RTS Receiver: 120 VAC
switch or remote. This controller offers all the same ease and
convenience of the RTS™ System without the need for an RTS hand-held RF transmitter:
intelligent motor. 3V Lithium battery, type CR2430

RTS features: RTS RF Wall Switch:


3V Lithium battery, type CR2430
• Wireless control of non-proprietary AC motors.
Operating frequency: 433.42 MHz, and has a range of
• An integrated system of new wireless RF controllers
90 ft. (30m) in open space and 65 ft. (20m) through two
including the RTS hand-held transmitter and the RTS
concrete walls.
wall switch.

• Eliminates wiring between switch and controller.

• With the RTS four channel hand-held transmitter or RTS


wireless wall switch you can program the Inteo receiver/
controller for individual, group and master control so that with
the touch of a button you can control all the shades in the
room or on the entire floor (within the range).

• For greater security the RTS control points are equipped 16


million rolling codes which dramatically reduce interference.
You can also choose and change the position of the control
point according to your needs.

• The RTS system not only provides the ease and convenience
of a remote, but also eliminates the need for long wire runs
to connect switches.

• The RTS control receiver provides up to 2 user-programmable


intermediate stop positions.

* RF control should be evaluated for acceptability in Healthcare, government,


airport and/or other facilities where RF signals may interfere with life critical
operating systems. Continued ☞
MechoShade Systems, Inc.
42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.44
MS2200 - 6/1/04

© Copyright 2004, MechoShade Systems, Inc., Long Island City, NY. MechoShade and ElectroShade are registered trademarks of, and IMCS, IQ/MLC, MLC and AAC SolarTrac are trademarks of MechoShade Systems, Inc.
Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

Wireless Controls – Networked


Electronic Control Systems: RTS™ Wireless

RTS Peripherals

RTS™ Receiver with Contact Outputs:


This RTS radio frequency receiver allows operation
of low voltage-hardwired controls from RTS- PR
LR RR RV
equipped switches, transmitters, timers and other AC/DC C NO C NO NF

LV 0V 12V 24V

accessories. It offers dry contact outputs controlled PV


- + +

1 2 3 4 5 6 7 8 9 10

by RTS radio signals.


BASE W/CLEAR COVER ANTENNA
P/N: RTSR 0450 CO CL

RTS Sun/Wind Sensor and Remote Receiver:


Single motor control. Set includes an integrated
radio receiver, sun sensor, wind sensor and low
voltage switch inputs. Solar brightness is continuously
monitored, triggering the control to raise/lower the
shades automatically as needed.

P/N: STRS 1051 KT 01

Battery Holder

RTS Dry-Contact Interface: RED


BLACK
The RTS Dry-Contact Interface enables wireless GREEN
WHITE

control of RTS motors and controllers from home


Programming Button
automation or other third party systems.

P/N: INTE 0454 DR CO

MechoShade Systems, Inc.


42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.45
MS2200 - 6/1/04

© Copyright 2004, MechoShade Systems, Inc., Long Island City, NY. MechoShade and ElectroShade are registered trademarks of MechoShade Systems, Inc. RTS is a trademark of its respective company.
Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

AAC-SolarTrac™ Window Management System


Automation for low voltage Standard or Intelligent Motor Control Systems.

The AAC SolarTrac™ Window user defined point within the


Management System is designed space.
to automatically adjust the position ■ Incorporates user defined internal
time delays, for intermittent
May be used with:
clouds and sun/no sun sky
• IQ/MLC™, MLC™
• Intelligent Motor Control conditions and cycles the
System™/2 (I•CON™) shades on a programmed basis.
May be interfaced with most ■ During nighttime winter
Building Management Systems
conditions it lowers the shades
(BMS)
to provide additional insulation
if desired.
of the shades incrementally
throughout the building to maximize ■ During nighttime summer
view and daylighting while protect- conditions it raises the shades
ing people and work surfaces from to assist in nighttime cooling.
direct sun when and where needed, ■ Includes manual override
using a PC-based program. capability by zone for executive
SolarTrac’s intelligent multi-level offices, conference rooms and
command accounts for “Clear” or training facilities.
“Cloudy” sky conditions in
■ MechoShade Systems, Inc.
accordance with established criteria
can monitor, perform system
for vertical, horizontal or sloping
diagnostics and make
windows. In addition, it factors in
adjustments via modem
the sun’s angle of incidence, solar
anywhere in the world.
heat-gain (in BTUs or W/M2), allow-
able solar penetration, plus bright- ■ Integrates with building-
ness and glare control. management systems. (Optional)

The AAC SolarTrac™ Window


Management System is a AAC SolarTrac™ Window
multi-zone controller that: Management System
■ On a daily schedule, automatically benefits include:
positions the shade to meet ■ Window shade alignment.
varying sun angles.
■ Uniform building appearance by
■ Using 3 radiometers, it elevation.
determines the momentary
■ Optimizes use of natural light
microclimatic conditions such
and views to the outside.
as sunny, cloudy or bright-
overcast sky conditions. ■ Provides HVAC engineers with ON SPR
SUM
ME
R
NO ING
/F
the flexibility to downsize air WIN
TE AL
■ Maximizes the amount of natural R
L

conditioning or to operate at a
light and view thru the window 7AM S 5PM
higher temperature set point.
by keeping the shade as high 6AM
E W
6PM

up as possible while not allowing 5AM 7PM


N
the sun to penetrate beyond a Continued ☞ Allowable Solar Penetration

MechoShade Systems, Inc.


42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.46
MS2200 - 6/1/04

© Copyright 2004, MechoShade Systems, Inc., Long Island City, NY. MechoShade and ElectroShade are registered trademarks of, and IMCS, IQ/MLC, MLC, I•CON and AAC SolarTrac are trademarks of
MechoShade Systems, Inc. Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

AAC-SolarTrac™ Window Management System

■ Improves productivity by: • Using solar meters, determines the compatible with:
1. Improving personal comfort. momentary micro-climactic conditions ElectroShade motorized solar sun
(clear, cloudy, or bright-overcast). screens utilizing Motor Logic
2. Maximizing view and healthy
• Incorporates user adjustable internal Controllers (MLCs), IQ/MLCs, Smart
exposure to natural daylight.
time delays, which adjust for Submasters. using standard
3. Regulating brightness and asynchronous motors.
intermittent clouds.
glare on CRT screens to
• During nighttime winter conditions, ElectroShade motorized solar sun
reduce eye strain and
lowers the shades to provide additional screens utilizing Intelligent Motor
improve productivity.
insulation; during nighttime summer Control (IMC) System.
conditions, raises the shades.
Description of Operation
Almost unlimited programming options B. Software
The multi-zone, multi-position, PC-based
are available to the end user such as 1. Each zone on each floor in each
AAC SolarTrac™ Window Management
lowering shades, at night and winter building (or building module) shall
System was developed exclusively for
to reduce heat loss and/or reduce be independently addressable.
the operation of ElectroShades®.
internal illumination transmitted out
The system is an intelligent multi-level 2. For raising and lowering shades,
of the building.
command program which automatically each zone shall have typically 3
• Includes manual override capability default intermediate aligned stop
adjust the position of shades incremen-
by zone. positions (25, 50 and 75% down) plus
tally, in accordance with the sun’s angle
of incidence, solar heat-gain factors in • Incorporates on-site-adjustments to full up and full down. As an option
BTUs, and allowable solar penetration. operating standards, either by user or additional programming can provide
remotely via modem by MechoShade. up to 16 incremental positions.
The system allows for brightness and
Increment “0” represents the fully
glare control by adjusting the shades to
raised position. If five increments are
“clear-sky”, “cloudy-sky”, or “bright-over- Master Specifications
selected for a particular zone of a floor
cast-sky” conditions. The AAC-SolarTrac A. Hardware of a building, the “0” setting indicates
system incorporates these elements
1. The AAC SolarTrac Window all the way up while “4” indicates fully
in accordance with an established
Management System shall be down, with each increment one fourth
computer program for vertical,
equipped with a standard desktop PC of the total travel height.
horizontal, or sloping windows.
or compatible computer with all the 3. Each zone on each floor in each build-
necessary interfacing, hardware and ing (or building module) shall have a
The AAC SolarTrac System is a software to accept the following: set of tables which corresponds to a
multi-zone controller that:
a. Analog inputs for solar meters user-defined range of dates, times,
• On a 365-1/4 day solar analysis, AAC (solar-level detection). and shade positions. The user can
SolarTrac automatically positions the b. Analog inputs for optional access these tables via the key board
shades to meet varying sun angles. temperature sensors. and through menu-driven screens.
This is accomplished utilizing ASHRAE c. Digital inputs for building-computer 4. Each table shall have a user-definable
clear day radiation as compared priority commands. set of solar-level conditions. These
micro-climactic conditions at the site d. Inputs for fire alarm and additional levels shall define “clear-day”, “over-
provided through three redundant non-designated ports. cast-glare”, and “bright overcast
solar meters via analog inputs
sky” conditions. For the “clear-day”
into the system. 2. The AAC SolarTrac software is mode, the shades shall follow the

Continued ☞
MechoShade Systems, Inc.
42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.47
MS2200 - 6/1/04

© Copyright 2004, MechoShade Systems, Inc., Long Island City, NY. MechoShade and ElectroShade are registered trademarks of, and IIMCS, IQ/MLC, MLC and AAC SolarTrac are trademarks of MechoShade Systems, Inc.
Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

AAC-SolarTrac™ Window Management System

programmed positions. The other two C. Sub-Master Controllers C. Intelligent Motor Control System
OR
modes represent special conditions IQ/MLC™ System (or MLC™) (I•CON™)
when the shades move to a 1. The I•CON is an Intelligent Motor
1. There shall be one INTELLIGENT
specified position. Control system with a microprocessor
SUB-MASTER controller on each
5. Each zone shall have user-defined floor, in each building (or building for each motor, with bus line 2 way
delays for cloud and sun conditions to module), as required. communication between the motors,
prevent intermittent clouds or sun from bus line and intelligent motors. The
2. Each INTELLIGENT SUB-MASTER
triggering the above special modes. PC shall be connected to the PC via
shall have 16 I/O ports and be able
6. Each zone shall have user-defined the RS-485 Interface port. Analog
to accommodate up to 8 MLC’s, or
priority-command positions to Input from three (3) Redundant Solar
8 IQ/MLC’s with full up/down
accommodate alarm-signal indicators Sensors which shall be communicated
operation. Or accommodate up
which are relayed from the building to the RS-485 card in the PC.
to 5 IQ/MLC’s with full function
computer. intermediate stop positions. 2. There shall be a RS-485 INTERFACE
7. Designated zones may have user- for each 256 zone control network or
3. Each INTELLIGENT SUB-MASTER
defined time-of-day accessibility. The as required.
controller shall accept up to two (2)
locally accessed Submaster and Local multi-conductor shielded-serial- 3. Each RS-485 INTERFACE controller
controls shall be returned to the auto- communications cables, one in and shall accept up to two (2) multi-con-
matic (AAC SolarTrac) master-computer one out, providing a daisy-chain ductor shielded-serial-communications
unit at a user-defined time or period. connection to the other INTELLIGENT cables, one in and one out, providing
8. During normal operation, the status of SUB-MASTER controllers and to the a daisy-chain connection to the other
all zones on each floor in each building AAC-SolarTrac master-computer unit. RS-485 INTERFACE controllers and
shall be displayed. Solar-intensity to the AAC-SolarTrac master-computer
4. Each INTELLIGENT SUB-MASTER
levels shall be displayed and indoor unit.
controller shall be intelligent and shall
and outdoor temperature readings can decode signals from and respond 4. Each RS-485 INTERFACE controller
be displayed as an available option. interactively with the AAC-SolarTrac shall be intelligent and shall decode
9. Operation of the shade motors master-computer unit. signals from and respond interactively
throughout the system shall be stag- with the AAC-SolarTrac master-
5. Each INTELLIGENT SUB-MASTER
gered so that peak electrical-loading computer unit.
controller shall accommodate up to
conditions are prevented. five or eight zones. 5. Each MOTOR-CONTROL zone shall
Remote access software shall also be a low-voltage-control system of
6. Each MOTOR-CONTROL zone shall
be provided to enable monitoring the the type indicated in specification
be a low-voltage-control system of
performance of the system from a section and as indicated on the
the type indicated in specification
remote location via a dedicated electrical drawings.
section and as indicated on the
analog telephone line provided by electrical drawings.
the end user.

MechoShade Systems, Inc.


42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.48
MS2200 - 6/1/04

© 2004, MechoShade Systems, Inc., Long Island City, NY. SolarTrac and I•CON are trademarks of, MechoShade Systems, Inc. Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

ElectroShade® Electrical Notes For Standard Motors


Line Voltage Switching (1-2 motors)
Low Voltage Control with IQ/MLC™, MLC™ or FTS’s (3 or more motors)
All electrical control equipment (Switches, MLCs™, IQ/MLCs™, Green motor wires are to be fastened to the ground junction
SACs, WACs, photocells, anemometers FTS units, etc.) as boxes, conduits, or another suitable building ground.
indicated is furnished only by MechoShade Systems, Inc.,
The standard ElectroShade® motor lead is a PVC 4 conductor
installed and connected by (Electrical Contractor) or (turnkey
#18 standard cable approximately one-foot (305mm) long with
by the window covering contractor).
a 4-conductor disconnect pole type plug.
All electrical control equipment must be wired in accordance
The standard ElectroShades are furnished with a 115 VAC
with wiring diagrams and Standard Electrical Notes prepared
(230 VAC) motor lead, approximately one foot (305mm) long,
by MechoShade Systems, Inc. and in accordance with the
with a locking disconnect plug. A standard junction box lead,
N.E.C. and local codes.
approximately 5 feet (1525mm) long, is furnished with a
Parallel and/or series wiring of two or more motors on a single disconnect plug which is compatible with the plug on the
switch or any other similar combination will void any applicable motor lead.
warranty and cause improper operating, premature motor
Line Voltage Switching of one to two motors
failure and burnout if not otherwise instructed
One or two motors can be wired on a single double-pole,
All wiring diagrams have been prepared for right-hand motors
double-throw switch. Please refer to pages 4.10 and 4.11
regular-roll, or left-hand motors reverse roll which are wired
for point-to-point connections.
similarly. Right-hand motors, reverse-roll and left-hand motors
regular-roll, require reversing the red and black motor wires Low Voltage Switching of three or more motors
at the MLC or IQ/MLC or at the switch. This will prevent the
Three or more motors wired to a single switch require the
motors from running in opposite directions when left-hand
use of a four (4) motor controller such as the MLC or IQ/MLC.
regular-roll or right-hand reverse-roll motors are installed.
Five to eight motors require two such controllers; nine to twelve
All control equipment, MLC’s (Motor-Logic Controllers) and all motors require three; and so forth. For MLC point-to-point
equipment that may have a transformer for A/C low voltage connections see pages 4.17 and 4.18, and for IQ/MLC see
must be wired in phase. If not in phase, premature transformer pages 4.26 and 4.27.
and/or motor burnout and inconsistent control operation may
Some point-to-point wiring diagrams may not include motor
occur. IQ/MLC’s have 12 VDC output and may be wired out
disconnect-plugs, junction boxes, and cable raceways that
of phase.
may be essential for a complete installation.
Electrical-control equipment may contain electro-mechanical
Note: Maximum distance low voltage wire run connected
relays, adjustment points, fuses, indicator lights, etc. These
in series is 400 ft.
must be accessible for future service and adjustment in a
readily available location during normal working hours without Conditioned Line Requirements
disruption to the existing operations. This equipment shall be
Line voltage must be maintained between 108 and 132 Volts
coded by the Electrical Contractor to indicate shade location
for 115 VAC systems and 207-253 Volts for 230 VAC systems.
and specific motor controlled at control equipment and circuit
In the event of spikes or drops in line voltage in excess of 10%
breaker. As-Built Drawings shall be provided by others for
the system may lose Memory/Programming.
future service.
Operating voltage below 108 Volts (207 Volts) (Brown-outs)
IQ/MLC’s have dip switch controller(s) and must be installed
may cause unanticipated performance of the motors and
in a readily available location for proper service and future
control system. Discontinuance of power (shut-off) will not
changes.
effect IQ/MLC memory of Intermediate Positions.
All motors are furnished with disconnect plugs for below ceiling
FTS Double Motor system —115VAC (230VAC) utilizes a
installation. Hard wiring will void all responsibility for cost of
control module with low voltage switching. Ten (10) or more
servicing and may void warranty. The MechoShade Warranty
control modules may be wired in series or in parallel for a
does not include the cost of labor to remove or install or access
single master switch which shall be double pole double throw.
to MechoShade equipment as specifically stated in the MSS
warranty.
Continued ☞
MechoShade Systems, Inc.
42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.49
MS2200 - 6/1/04

© Copyright 2004, MechoShade Systems, Inc., Long Island City, NY. MechoShade and ElectroShade are registered trademarks of, and IQ/MLC, MLC, Motor Logic Controller and SolarTrac are trademarks of,
MechoShade Systems, Inc. Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

ElectroShade® Electrical Notes For Standard Motors

Standard Motor Switching 5. Optional RS232/485 Interface: RS485 protocol with a


PC requires a 485 PC card or an optional IQ/MLC RS232
The following is a brief summary of the various switching
or 485 Adapter. Up to 5 zones per interface adapter, up to
configurations that can and must be used with
12 IQ/MLC units per zone. Allows a total of 60 control units
ElectroShade® standard motors.
per interface.

Line Voltage Switching


1. One Motor, One Switch: This arrangement requires a MLC™ Four Motor Controller
double throw (on/off/on) switch. Either single or double-pole 1. Four Motors, Master Switching Only: Each MLC handles
switches can be used. (MechoShade® Systems stocks up to four motors. Momentary or maintained switches can
only double-pole, double-throw switches as standard be used. Master.
equipment.)
2. Two or More Master Switches: Each switch must be a
2. One Motor, Two or More Switches: A multi-switch momentary switch. Any switch will control all the motors
command enables two or more momentary switches to simultaneously. Master switching only.
be used with a single motor.
3. Remote Control: Wireless transmitters and receivers
3. Two Motors, One Switch: A double-pole, double-throw are available. Optional.
switch (D.P.D.T.) is required and can be momentary or
maintained.
4. Two Motors, Two or More Switches: Momentary center SkyLighter™ Double Motor System (SDMS/FTS)
off switches must be used.
1. SkyLighter™ Double-Motor Tension System: SkyLighter
5. Remote Control: Wireless transmitters and receivers are shade operation utilizes a pair of operating motors with a
available. low voltage Double-Motor Control Module to establish and
maintain a taught horizontal or inclined shade. A single
IQ/MLC™ Four Motor Controller Double-Motor Control Module is required for each pair of
operating motors. Two (2) or more SDMS modules can be
1. Four Motors, Four Local Switches and Two Master Switch wired in parallel or series to a single momentary contact
Ports With 3 Auto Intermediate Stop Positions:. Each switch.
IQ/MLC handles up to four motors. Three button switches
provide intermediate window positioning at the touch of a
button. Motors can be assigned to any combination of the AAC SolarTrac™ System
four motors and four Local Switches connected to an
IQ/MLC to create groups and sub groups. Master Switch 1. AAC SolarTrac™: A PC based user-defined program
controls all. that automatically adjusts window shades to the year/day
solar condition. Determines the microclimatic conditions
For 1 to 4 motors require one IQ/MLC. Five to eight motors and adjusts the shades incremently on the window to
require two IQ/MLC’s. Nine to twelve motors require three, anyone of 5 or more positions on a window. All shades
and so forth. are adjusted in accordance with the solar load, solar
2. Intermediate Stop Positions: Three intermediate stop penetration and the particular facade of solar orientation
positions plus full up and full down. Five positions total. as established by the user.
Custom set intermediate stop positions or auto stop at Low Voltage Accessories / Definitions
25%, 50% and 75% of window height.
1. Sun-Activated Control (SAC): The SAC module is
3. Two modes of operation: “UniformMode™” for uniform furnished with a “K” Value photo sensor. The SAC module
window covering operation and building exterior. Shades has manual/auto mode selector plus master switching in
may only stop at preset positions. “Normal Mode” for five the manual mode. An optional Remote Manual/Auto
auto stop positions plus stop anywhere on the window. Switching Controller is available. Compatible with the MLC
4. Internal Motor/Switch Assignments: Motors and switches and IQ/MLC motor controllers. The IQ/MLC requires an
can be assigned to each other by adjusting the internal optional interface.
on/off Switch/Motor Dip Switch controls.

Continued ☞
MechoShade Systems, Inc.
42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.50
MS2200 - 6/1/04

© Copyright 2004, MechoShade Systems, Inc., Long Island City, NY. MechoShade, ElectroShade, ThermoVeil, DualShade, and SnapLoc are registered trademarks of, and IMCS, IQ/MLC, MLC, , AAC SolarTrac, UniformMode
and SkyLighter are trademarks of MechoShade Systems, Inc. Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

ElectroShade® Electrical Notes For Standard Motors

2. Wind-Activated Control (WAC): The WAC module is 6. Switches: A complete line of low voltage and line voltage
furnished with a “K” Value photo sensor. The WAC module switches are available as:
has manual/auto mode selector plus master switching in the
• Paddle switches (maintained): for the MLC Four Motor
manual mode. An optional Remote Manual/Auto Switching
Controllers.
Controller is available. Compatible with the MLC and IQ/MLC
motor controllers.The IQ/MLC requires an optional interface. • Rocker switches (maintained and momentary): for MLC
Four Motor Controllers.
3. 24-Hour Timer: A 24-hour timer is furnished with a remote
manual override switch. Compatible with the MLC and IQ/MLC • Décor switches (pulse): for MLC and IQ/MLC Four Motor
motor controllers. The IQ/MLC requires an optional interface. Controllers.
4. IR or RF Remote Control (A/V or Bus): An IR or RF remote • Indoor key switches (maintained and momentary): for MLC
control through the use of a hand-held transmitter. Remote and IQ/MLC Four Motor Controllers.
controls are available for the MLC and IQ/MLC Four Motor
Controllers. • Digital key pads: for MLC and IQ/MLC Four Motor
Controllers.
5. RS-232 Interface: RS-232 translates the RS-232 protocol
for use with ElectroShade controllers. This addressable unit • Plus, Lite-Touch Type H Series (or similar pulse type
connects any PC, building automation or lighting system to switch) for IQ/MLC Four Motor Controllers and I•CON Bus
the MLC and IQ/MLC Four Motor Controllers. Line System:

The RS-232/485 interface provides up to 5 zones per interface IQ/MLC (full funtion up/down, stop with 3 intermediate
adapter, up to 12 IQ/MLC units per zone. Allows a total of 60 stop positions on a 3-button single station or 6-button
control units per interface. dual station switch).

RS232: P/N: EMLC 0232 RS MO (PC to 1st interface) I•CON (full funtion up/down, stop with 3 intermediate
RS485: P/N: EMLC 0485 RS MO (interface 2 and up) stop positions on a 4-button single station or 8-button
dual station switch).
I•CON™ has a dedicated Wide Zone switch port for access to
the entire system.

MechoShade Systems, Inc.


42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.51
MS2200 - 6/1/04

© Copyright 2004, MechoShade Systems, Inc., Long Island City, NY. MechoShade and ElectroShade are registered trademarks of, and IMCS, IQ/MLC, I•CON and MLC are trademarks of MechoShade Systems, Inc.
Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

ElectroShade® Systems Specifications


For Standard and Intelligent Motor Control Systems

Description 1.3 Brake: A solenoid activated disc brake mechanism shall


The ElectroShade Motorized Shading System consists of
® stop and hold the shadeband in any position. The brake shall
automatically disengage when the motor is operating.
Section 1.0 ElectroShade Motor System
1.4 Gear Box: Multiple levels of satellite gears shall be
Section 2.0 Switching and Control System For Standard and
provided for load distribution (planetary gears) and machined
Intelligent Motor Systems
from close tolerance tempered steel. The speed shall vary
Section 3.0 Electronic Relays (IQ/MLC™ and MLC™ Four according to the motor model from 10 r.p.m. to 64 r.p.m.
Motor Controllers)
1.5 Installation: A single pin, or star spring wire, shall lock
Section 4.0 Intelligent Motor Control System™/2 (I•CON™) the drive end of the motor to the tube. A notched section of the
Section 5.0 Sun Activated Control tube shall turn the ring, which counts the turns and activates
the limit switch. To interchange motors, the pin or spring shall
Section 6.0 AAC SolarTrac™
be pressed out of the tube and the able to motor slide out.
Section 7.0 Controls and Switching
1.6 Sizes: The motors shall be available in torques of 35-435 in.
Section 8.0 Pockets and Accessories lbs. (lifting capacity), 10-64 r.p.m. speed to meet specified
Section 9.0 Shade Cloth, Films, Laminates requirements and shall not exceed 60 mm in diameter as
115 VAC (230 VAC) motors.
1.7 Warranty: The manufacturer shall provide a warranty that
The System is designed, developed and fabricated to be a
the motor is free of manufacturing defects for five (5) years from
totally integrated unit and is furnished by the manufacturer,
the date of sale. This warranty shall be void if the products have
MechoShade Systems, Inc., with a warranty which provides
been improperly installed, wired or subjected to improper care.
that all components (motor, shade cloth, electrical controls
and override circuits) have been designed, tested and
approved as a compatible system. 2.0 Switching and Control Systems for Standard and
Intelligent Motor Control Systems
1.0 ElectroShade® Motor System [Select the appropriate components for an Intelligent system].
All systems shall be U.L. or E.T.L., CA or EU requirements
1.1 Motor: The motor shall be an asynchronous (non-synchro-
listed and meet electrical code requirements.
nous) motor, with a built-in reversible capacitor start-and-run,
and shall operate at 108 to 132 VAC at 60hz. (216-264), 2.1 Control Wiring for Line Voltage Switching: One or two
in single phase, with a Class-A temperature rating (max. ElectroShades shall be controlled by a single line voltage
temperature rating of 140 C.). The motor shall have thermal- D.P.D.T switch.
heat protection and be totally enclosed and maintenance free, 2.1.1 Manual Switches: Double pole, double throw center off
with a locking disconnect plug assembly furnished with each manual switches shall operate one or two motors per switch.
operator. For intermittent operation of ON ±5 minutes / OFF For three (3) or more motorized shades, low voltage controllers
±30 minutes the running time will vary slightly with each motor. shall be required. (IQ/MLC and I•CON.)
Motor running time after thermal overheating shall be ± 3
minutes at room temperature.
3.0 Electronic Relays (IQ/MLC™ and MLC™ Controllers
1.1 Electronic Motors shall have either a manual thumbscrews,
Four (4) Motor Controllers)
push-button or electronic limit switch for adjustment.
[Select the appropriate Four Motor Controller the capabilities
1.2 Limit Switches: Internal limit switches, adjusted electronically
desired].
or by two external thumbscrews or push-buttons, shall allow the
exact setting of travel in both the raised and lowered positions. Each Four (4) Motor Controller (listed below) shall provide low
Micro switches shall provide circuit braking at the end of the voltage control capability over line voltage standard motors
run. The limit switch setting will not be disturbed by the action (115 VAC) (230 VAC); isolating up/down control relays between
of the roller tube. the switch ports and motors for low voltage control. Each Four
(4) Motor Controller shall offer specified levels of control for

Continued ☞
MechoShade Systems, Inc.
42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.52
MS2200 - 6/1/04

© Copyright 2004, MechoShade Systems, Inc., Long Island City, NY. MechoShade, ElectroShade and SnapLoc are registered trademarks of, and IMCS, IQ/MLC, I•CON, MLC and AAC SolarTrac are trademarks of MechoShade
Systems, Inc. Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

ElectroShade® Systems Specifications


For Standard and Intelligent Motor Control Systems

master and/or local individual/group control according to the set intermediate stop positions plus full up/down or anywhere
capabilities and features of each system listed below. Each on the window. In the UniformMode, the shades may only stop
Four (4) Motor Controller shall be compatible with Sun- at the 3 custom or auto set intermediate stop positions plus
Activated Controllers and Wind-Activated Controllers, 24-Hour full up/down. UniformMode option shall be available through
Timers, Key Switches and Digital Key Pads and Remote special button pushes.
Control. (An interface may be required depending on the 3.1.5. Reconfigure Switching Capability Without Rewiring:
accessory and Four Motor Controller selected). The IQ/MLC shall allow for “reconfiguration” any of the four
All Four (4) Motor Controllers shall have 4 fuses, line voltage motors connected to an IQ/MLC by simply reassigning the
transformers that convert line voltage currents to allow for switch/motor assignments of any local switch port utilizing
low voltage multi-switch control. the local switch port DIP switches within the IQ/MLC and
All Four (4) Motor Controllers shall be U.L. or E.T.L., CA or EU activating the reset button on the PC board. Any switch may
requirements listed and meet electrical code requirements. be configured to control any combination of the four motors.
3.1.6. Master Control Of More Than Four (4) Motors: The
system shall be able to allow for daisy chaining of two or more
3.1 IQ/MLC™ Low Voltage Four (4) Motor Controller
IQ/MLC’s, utilizing the master switch ports, for master control of
(option)
five (5) or more motors. With an IQ/MLC Sub Group Controller
In addition to 3.0 above, each IQ/MLC Four (4) Motor Controller (P/N: IQML SGC6 RJ BD) connecting up to four (4) IQ/MLC
shall have: units, a total of 16 motors and local 16 switches, shall be possible
3.1.1. Master Control with Local Individual/Group Control: on a single master switch circuit. A maximum of 12 IQ/ML’s, a
Each IQ/MLC shall have master control able to control all total of 48 motors and local 48 switches, may be daisy-chained
motors connected to all IQ/MLC’s on the same circuit; and have on a single circuit from master switch circuit.
four (4) 12 volt local switch ports which control any combination 3.1.7. RS-232/485 Compatibility Option: If the RS485 protocol
of the four motors connected to each IQ/MLC controller. Local is required then a 485 PC card or an IQ/MLC RS232 or 485
switch port connections shall be 4-conductor telephone style Adapter is required and shall allow up to 5 zones per interface
RJ11 and master switch port connections shall be 6-conductor adapter, up to 12 IQ/MLC units per zone. A total of 60 control
RJ12. Switches shall be either 3-button single station, 6-button units per interface.
dual station Lite-Touch Type H Series (or similar pulse switch)
RS232: P/N: EMLC 0232 RS MO (PC to 1st interface)
or a 3-button single station Décor switch for full up/down and
RS485: P/N: EMLC 0485 RS MO (interface 2 and up)
3 intermediate stop position functionality.
3.1.2. Assignable Local Individual/Group control: The IQ/MLC
shall allow for assigning any of the four motors connected to an 3.2 MLC Four (4) Motor Controllers
IQ/MLC by simply assigning the switch/motor assignments of In addition to 3.0 above, each MLC Four (4) Motor Controller
any local switch port utilizing the local switch port dip switches shall have:
within the IQ/MLC.
3.2.1. Master Control ONLY: Each MLC shall have master
3.1.3. IQ/MLC, Automatic Shade Alignment with (5) Five Stop control able to control all motors connected to all MLC’s on
Positions and Auto Intermediate Stop Functionality: The the same circuit. Up to 25 MLC’s, a total of 100 motors and
IQ/MLC shall provide automatic shade alignment according to 2 switches, may be wired together on a single switch circuit.
the combination of buttons pressed at the switch for any of 5 Note: MLC’s cannot have individual, group or overlapping
positions for full up/down and 3 intermediate stop positions. switch control and are not available with intermediate stop
The intermediate stop positions shall be either auto set at 25%, positions.
50% and 75% of the window height or custom set as required.
Auto alignment of all shades will automatically occur regardless
of weight or size to each of the individual stop points or 4.0 Intelligent Motor Control System™ (I•CON)
up/down positions. I•CON shall provide a complete shade control system with
3.1.4. IQ/MLC, Normal Mode and UniformMode™ of Operation: two-way busline communication for low voltage control capability
In the normal mode, shades shall stop at the 3 custom or auto over line voltage standard motors (115 VAC) (230 VAC);

Continued ☞
MechoShade Systems, Inc.
42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.53
MS2200 - 6/1/04

© Copyright 2004, MechoShade Systems, Inc., Long Island City, NY. MechoShade, ElectroShade and SnapLoc are registered trademarks of, and IMCS, IQ/MLC, MLC, UniformMode and AAC SolarTrac are trademarks of
MechoShade Systems, Inc. Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

ElectroShade® Systems Specifications


For Standard and Intelligent Motor Control Systems

isolating up/down control relays between the switch ports and address in their BI Wide Zone address table shall respond
motors for low voltage busline control. I•CON™ shall be to any and all Wide Zone switch commands with the
compatible with Sun-Activated Controllers and Wind-Activated corresponding address.
Controllers, 24-Hour Timers, Key Switches and Digital Key 4.2 Local Zone Switching: The standard Local Zone Switch
Pads and Remote Control. (An interface may be required (LZS) does not contain a microprocessor and is connected
depending on the accessory). to the BI on the left or right side. Each standard Local Zone
I•CON shall be U.L. or E.T.L., CSA or EU requirements listed Switch, shall broadcast one Local Zone Address from the BI
and meet electrical code requirements. for that switch. Up to two (2) Local Zone switches may be hard
4.1 The I•CON system shall consist of: wired to the BI via terminal blocks or RJ12 connectors, one
4.1.1 A two motor Bus Interface (BI). each for operation of each of the left and right motors; and
for broadcasting over the bus line.
4.1.2 Local Zone Switches (connected to the BI).
All motors with the same address in their BI Local Zone
4.1.3 Wide Zone Switches (connected anywhere
Address table shall respond to any and all Local switch
on the busline).
commands with the corresponding address.
4.1.4 Hand-Held Configurator which shall access
4.3 Alignment: I•CON shall have full up/down and stop
the BI for the following:
functionality with up to 4 aligned intermediate stop positions
4.1.4.1 Selecting any BI by Location (4 digit.) (20%, 40%, 60% and 80% fo the window height) or custom
4.1.4.2 Select BI Motor (Left or Right). selected stop positions or any combination thereof.

4.1.4.3 Cause any motor to “WINK” for verification All shades, regardless of size or weight will align at each of
of location. the intermediate stop positions.

4.1.4.5 Access or Change Local Zone address. Shade system shall have the capability of exactly repeating the
selected stop position from the top down or bottom up cycles.
4.1.4.6 Access or Change Wide Zone addresses.
4.4 Programming:
4.1.4.7 Access or Change BI Location address.
A hand-held Programmer shall be provided in order to program
4.1.4.8 Access Normal/UniformMode™s and
the system as listed in 4.1.4. The programmer may be attached
change accordingly.
to any Wide Zone Intelligent Switch (WZS), or to the bus line or
4.5 Bus Supply shall maintain power over the busline. any BI. This dedicated unit shall be able to be used in place of
4.6 Busline Repeater shall maintain the signal over the a computer to access the bus line, affect changes
busline beyond 64 nodes. or monitor the system.
4.7 Bus Supply/Repeater shall maintain both the power
and signal over the busline beyond 64 nodes. 5.0 Sun-Activated Control (SAC)
4.1.2 Switching: The I•CON shall have a two Motor Bus (sun daylight intensity, up/down only)
Interface (BI) with 8 Wide Zone Addresses and 2 Local Zone A Sun-Activated Control shall automatically operate the interior
Addresses, for a total of ten addresses per motor. Each BI shades (up or down), when the daylight intensity at the window
shall have a micro-processor with a unique Neuron ID. Motors reaches a pre-set level. An adjustable time-delay control for
connected to a BI shall respond to a command from any Wide cloudy days shall be included. The system shall consist of a
or Local Zone switch with a corresponding address. solid-state central control unit and a separate photocell sensor
4.2 Wide Zone Switching: Each Wide Zone Intelligent Switch (that measures daylight K values). The photocell shall sense
(WZS) on the bus line shall have a micro-processor with a the daylight intensity at the window and activate the SAC unit
unique Neuron ID and can be connected anywhere in the to the move the shade(s). The sensitivity of the photocell shall
bus line. The Wide Zone Switch shall store one manually set be adjustable.
address. Wide Zone switches with different addresses shall 5.1 Externally Installed ElectroShades® with Anemometer and
have the capability to be wired in series to the bus line and to Photoelectric Control: For use with the externally installed
adjacent Wide Zone switches. All motors with the same ElectroShades, the photosensor is expanded to include an

Continued ☞
MechoShade Systems, Inc.
42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.54
MS2200 - 6/1/04

© Copyright 2004, MechoShade Systems, Inc., Long Island City, NY. MechoShade, ElectroShade and SnapLoc are registered trademarks of, and IMCS, IQ/MLC, I•CON, MLC and AAC SolarTrac are trademarks of MechoShade
Systems, Inc. Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

ElectroShade® Systems Specifications


For Standard and Intelligent Motor Control Systems

anemometer to measure wind velocity. Overrides the in. (65 mm), 3.55 in. (90 mm) or 4.5 in. (114 mm) OD (as
photosensor by raising shades when, and if, wind velocity required) with internal keyway to receive tubular motor. (The
exceeds a pre-set point. (See drawings in MechoShade® tube is also extruded with two fabric-mounting channels
literature.) All of the preceding versions may be implemented designed to support the shade bands without additional wraps
on local, submaster or master levels. On all control levels, of fabric on the tube, to permit mounting and dismounting of
manual override must be provided. AAC SolarTrac may be the shade bands and without requiring removal of the tube
needed. or motor assembly from the mounting brackets.)
8.2 Mounting Spline: Extruded vinyl with asymmetrical locking
6.0 AAC SolarTrac System (sun angle; incremental shade
™ channels and embossed fabric guide for use with 2.55 in. (65
movement; interior or exterior shades) mm), 3.5 in. (90 mm) and 4.5 in. (114 mm) OD tube. Spline
has sufficient capacity to support the shade and additional hem
Solar tracking software automatically adjusts shade positions
weights without disengaging from the tube without extra wraps
in accordance with the sun’s angle of incidence, solar heat-gain
of fabric on the tube. SnapLoc® Spline shade band assembly
factor in BTU’s or profile angle and allowable solar penetration.
may be installed or removed from the shade tube, or tube/motor
This multi-zone control system automatically calculates clear-
assembly, without disassembling or removal from their
sky solar values daily and also monitors the output of three
mounting brackets.
solar meters to determine if cloudy and overcast conditions
exist. Solar meters measure the total solar spectrum of U.V. 8.3 End Brackets: Consist of 1/8 in. (3 mm) or 3/16" (4.5mm)
daylight (K value) and IR (heat). When the AAC SolarTrac is thick sheet steel. Wall, jamb or ceiling mounted as required and
integrated in a system the number of aligned intermediate permanently installed. Brackets (without exposed fastening)
stop positions may be increased to 10, 20, etc. shall accept a continuous SnapLoc® Fascia (closure) friction
fit. Fascia shall be installed as a single unit over two or more
6.1 The AAC SolarTrac software has many user programmable
shade band assemblies without exposed joints in lengths
functions as well as complete manual override capabilities:
comparable to the maximum standard lengths of fascia
Integration with “smart building” systems is an optional feature.
available. Max. length 15 ft. (4572 mm).
Executive lockout daily switch control for executive and confer-
ence rooms. Integrates with the Intelligent Motor Control 8.4 Center Support Brackets: Supplied to meet span or weight
System™ (I•CON), and IQ/MLC™ Systems. requirements. Ceiling or wall mounted. Center support brackets
shall accept continuous lengths of fascia, which will span two
6.2 Custom-Designed Controls: Automatic shade controls
or more MechoShade® bands is at a minimum length of 15 ft.
which tie into a separate building management system, such
(4572 mm). Fascia shall be provided for standard height and
as HVAC and lighting, will be quoted on a job-by-job basis.
extended height brackets and in center support brackets.
Controls such as these would coordinate the automatic
Fascia shall be provided in minimum of 15 ft. (4572 mm)
adjustment of interior lights, HVAC and shading devices on
lengths and clipped on to two or more shades without both
a minute-by-minute basis in conjunction to climatic conditions,
notches for the shade bands.
pre-set levels of comfort, and sensed zone cooling or heating
requirements. 8.5 Hembar Weights: Mill-finished aluminum, flat bars, single
lengths for each shade panel.
8.5.1 Exposed hembars in painted and baked PPG finishes
7.0 Controls and Switching.
with key way for shades.
All electrical controls and switching systems are subject to
8.6 DualShade® Mounting System: The patented mounting sys-
the approval of local codes which must be employed in their
tem by MechoShade Systems, Inc., for installing ThermoVeil®
installation.
shade cloth and MirroFilm® to the same roller by means of
SnapLoc® fastener. The shade cloth and film shall
8.0 Pockets and Accessories Required for a be separated by a 1/2 in. (13 mm) second stagnant air space
Total Integrated System between the window and the room air environment. Lowering
the “U” value of the shade and glazing system.
8.1 Shade Roller: Extruded aluminum tube, 6063-T6 alloy, 2.55

Continued ☞
MechoShade Systems, Inc.
42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.55
MS2200 - 6/1/04

© Copyright 2004, MechoShade Systems, Inc., Long Island City, NY. MechoShade, ElectroShade and SnapLoc are registered trademarks of, and IMCS, IQ/MLC, MLC and AAC SolarTrac are trademarks of MechoShade
Systems, Inc. Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

ElectroShade® Systems Specifications


For Standard and Intelligent Motor Control Systems

8.7 Fascia: Extruded aluminum 6063T5 baked PPG enamel minimum 16 ga. coated steel. Exposed elements shall be
finish in standard colors specified. May be used for surface continuous extruded aluminum to match the 4113 Pocket
mounted ElectroShade System installation. Snaps on with closure assembly. Closure may be 2" (51 mm), 2 1/2" (63 mm),
concealed fastenings that hide the bracket assembly and 3" (76 mm), 5" (127 mm) or others as required for extruded
appears as a continuous unit when mounted side to side. aluminum 6063T5 baked PPG enamel finish. 10 ft. lengths.
Fascia shall be provided for Standard and Extended height 8.10 Finishes: All exposed aluminum parts have an anodized
shades. Fascia shall be provided in minimum of 15 ft. or painted finish which, under normal conditions, prohibits
(4572 mm) lengths. deterioration of the aluminum. Steel parts are either cadmium
8.8 4123 Pocket with Bottom Closure: Manufactured from plated, satin finished or have been bonderized prior to painting
extruded aluminum 6063T5 baked PPG enamel finish in with a baked enamel finish. All painted finishes are baked.
standard white or standard custom colors by special order. Sheet steel shall be paint-loc or equal.
Recessed Housing is specifically designed for acoustical
or plastic ceilings with removable closure plate for access
9.0 Shade Cloth, Films and Laminates
to the recessed and concealed roller system.
See specifications for ThermoVeil and DualShades in Section
8.9 Double Motor Pockets: Pockets of various sizes for double
5, pages 5.2, 5.5 to 5.9.
motorized shades or high bay shades shall be fabricated of

MechoShade Systems, Inc.


42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.56
MS2200 - 61/04

© 2004, MechoShade Systems, Inc., Long Island City, NY. Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

Third Party Integration – Under Consrtuction

MechoShade Systems controllers can seamlessly integrate


with third party control systems thru a variety of methods and
interfaces. This ability allows for the shading system to be
controlled through a common user interface which, for
example, might originate with Lutron’s Lighting Control System,
Crestron’s A/V Control System, Honeywell’s HVAC System
or a Johnson Controls’ BMS System.
The following pages are “under construction” and have been
designated to provide a continuing update as to how our
products integrate with the leading control systems in:
•Lighting – Integration with companies such as:
Leviton®
LiteTouch®
Lutron®
Vantage
•A/V – Integration with companies such as:
AMX
Crestron
•HVAC – Integration with companies such as:
Honeywell
Johnson Controls
•BMS – Integration with companies such as:
Honeywell
Johnson Controls
Siemens
Please go to:
www.mechoshade.com/site/electroniccontrolsystem/index.cfm
to view and/or download the most current integration
information, including wiring diagrams and techniques.

MechoShade Systems, Inc.


42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.57
MS2200 - 6/1/04

Copyright © 2004 MechoShade Systems, Inc. “MechoShade,” and “ElectroShade,” are registered trademarks of MechoShade Systems. “MLC” and “IQ/MLC” are trademarks of MechoShade Systems.
Specifications subject to change without notice.

http://SolarControlLLC.com
Solar Control, LLC | 888-550-4836

NOTES
___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

___________________________________________________________________________

MechoShade Systems, Inc.


42-03 35th Street, Long Island City, NY 11101
Telephone: 718-729-2020 E-mail: info@mechoshade.com
Fax: 718-729-2941 / 800-899-8081 Internet Web Site: http://www.mechoshade.com 4.58
MS2200 - 6/1/04

© 2004, MechoShade Systems, Inc., Long Island City, NY. Specifications subject to change without notice.

http://SolarControlLLC.com

S-ar putea să vă placă și