a r t i c l e
i n f o
Article history:
Received 29 February 2008
Received in revised form 20 July 2008
Accepted 21 July 2008
Available online 8 August 2008
Keywords:
Dual chamber vials
Rubber closures formulation
Methylprednisolone sodium succinate
Injection
a b s t r a c t
The unique approach in manufacturing of pharmaceutical dosage forms of active substances known to
be unstable in aqueous solution is the introduction of lyophilization process. Nevertheless, these products must be reconstituted using the diluent from a separate container before application. The possible
solution for this problem is the application of dual chamber vials comprising the freeze-dried product
in a lower compartment of the vial and the solution for reconstitution in the upper chamber. The main
issue in development of such product is the choice of contact packaging (rubber closures, glass vials
and the container closure system as a whole). The most important parameter used for evaluation of the
inuence of contact material on product quality was the pH value. The results have shown that the type
of vials (moulded or tubular glass) has no impact on pH shift of the solution for reconstitution (tested
solutionTS), while signicant differences in pH value of the TS were observed depending on the rubber
closures formulation used (with some formulations, the pH shift during the test was 6.59.14). Benzyl
alcohol assay during the tests remained unchanged. Integrity tests of the container closure system (CCS)
have demonstrated the adequacy of the selected packaging system. The quality of the CCS of choice was
conrmed in the course of stability studies, only parameters directly inuenced by CCS being presented
in this work: loss on drying and pH value. On the basis of these results, no changes in loss on drying were
connected to CCS, and the pH value of the reconstituted solution remains unchanged in samples tested
both ex-tempore and after in-use period of 48 h.
2008 Elsevier B.V. All rights reserved.
1. Introduction
New pharmaceutical dosage forms, as well as new delivery systems are more and more subject of development processes and
focus of the pharmaceutical industry, beside the introduction of
new pharmacological active substances. This is especially true for
the variety of well-known substances which are in use for many
years and connected with different problems related to existing,
conventional, pharmaceutical dosage forms. Because of the limited
stability in the presence of moisture, for some active substances it is
necessary to use the lyophilization process in order to achieve longterm stability. Problems associated with this type of injections are
complicated because the medication to be administered must be
stored as two separate component parts and then mixed, prior to
injection. This mostly applies to the risk of microbiological contamination, spilling during preparation, safety of medical personnel,
time consuming application and often need for urgent use of these
drugs. Therefore, dual chamber vials have been developed to facili-
745
Table 4
pH values of the TS in two types of glass vials under different storage conditions
Storage conditions
40 C/75% RH
30 C/65% RH
25 C/60% RH
Tubular glass
Moulded glass
6.50
6.54
6.40
6.36
6.08
6.07
Table 5
Benzyl alcohol assay (% of declared value) in TS after conditioning 4 weeks
Table 1
Storage conditions for integrity testing
Sample No.
Conditioning temperature ( C)
Time (months)
1
2
3
4
5
5
50
60
3
6
2
1
Storage
orientation
Accelerated
40 2 C/75 5% RH
Horizontal
Upright
0, 1, 2, 3 and 6
0, 3 and 6
Intermediate
30 2 C/65 5% RH
Horizontal
Upright
0, 3, 6, 9 and 12
0, 6 and 12
Long-term
25 2 C/60 5% RH
Horizontal
Upright
Initially
7 days
14 days
21 days
28 days
F1
F2
F3
F4
F5
F6
99.5
99.7
100.1
99.0
99.3
99.5
99.3
100.7
99.3
100.2
98.2
100.2
98.1
101.2
99.1
98.3
100.2
98.3
98.4
99.5
100.2
99.4
100.5
100.1
97.2
100.2
98.4
98.3
99.4
98.6
used. TS (5 ml) was placed in the lower chamber of tested vials and
stored at different temperatures/RH during 5 days. Both glass vials
were Type I glass containers: neutral glass, with a high hydrolytic
resistance due to the chemical composition of the glass itself. It
was needlessly to carry out test longer, because test for hydrolytic
resistance was also carried out to control hydrolytic resistance of
glass vials.
2.3. Rubber closures
Table 2
Storage conditions and testing frequencies
Storage conditions
Rubber formulation
2. Experimental
2.1. Model drug
Methylprednisolone sodium succinate [2] lyophilisate for injection was used as a model drug and water for injection with 0.9%
benzyl alcohol as diluenttest solution (TS). Benzyl alcohol as
preservation agent was used in the solution for reconstitution,
because the reconstituted solution has to be unchanged after in-use
period of 48 h.
Table 3
Testing points for in-use stability evaluation
40 C/75% RH
Sample/time (months)
30 C/65% RH
6
25 C/60% RH
12
12
24
60
746
The design of the formal ICH-compliant stability studies encompass the storage conditions and testing frequencies outlined in
Table 2. During the stability study, the vials were kept in horizontal, as well as, in upright position. Horizontal position was
chosen, for compatibility assessment, in other words to assure maximal contact of diluent of the subject drug product with rubber
closures.
Some of tested parameters could be directly inuenced by container closure system and therefore will be pointed out.
2.5.1. pH of reconstituted solution
Lyo-cake was reconstituted by pushing diluent into the lower
chamber. pH value was measured immediately after reconstitution.
2.5.2. Loss on drying
This test was performed in accordance with Ph. Eur 2.2.32.
In-use compatibility was also considered critical, since intermediate elastomeric closure is in contact with reconstituted
product during the 48 h period. In order to establish the quality
requirements, potential leachables were taken into account. This
was based on the extraction study for the selected rubber formulation, performed by manufacturer of the elastomeric closures.
In-use compatibility was assessed in the course of the stability
study using container closure system dened as an optimal solution in terms of chemical and physical characteristics as well as the
required functionality.
In-use stability/compatibility testing of the drug product was
performed according to ICH guidances [11,12].
In-use stability/compatibility testing is being evaluated by
examining quality parameters of the subject drug product susceptible to change at the end of the proposed in-use shelf life (i.e.,
at 48 h after reconstitution). The lyophilized product was reconstituted utilizing the water for injection with 0.9% benzyl alcohol
provided in the upper chamber of the vial. Samples were tested
inicially as well on the end of testing period, design is presented in
Table 3.
3. Results and discussion
Table 6
Results for Test II
pH values of TS
TS (blank)
Intermediate closures
Upper closures
Initially
14 days
Initially
14 days
6.92
7.11
7.31
6.51
6.96
7.22
99.7
99.5
99.0
98.6
100.4
99.8
747
Table 7
Results for pH value measured immediately after reconstitution of vials kept in upright (A) and horizontal (B) position
Storage interval (months)a
Conditions
1
Avials kept in upright position
7.50
40 C/75% RH
30 C/65% RH
25 C/60% RH
12
18
24
7.60
7.51
7.48
7.50
7.53
7.56
7.56
7.41
7.48
7.52
7.53
7.54
7.42
Conditions
7.38
7.59
7.55
7.60
12
18
24
7.60
7.50
7.62
7.56
Table 8
Results for loss on dryingsamples conditioned at different temperatures
Storage interval (months)a
Conditions
1
Avials kept in upright position
0.85
40 C/75% RH
30 C/65% RH
25 C/60% RH
12
18
24
0.70
0.65
0.76
0.47
0.96
0.77
0.72
0.32
0.40
0.98
0.97
0.50
0.89
Conditions
0.29
0.45
0.31
12
18
24
0.70
0.60
0.75
0.67
Table 9
Results for pH value during in-use testing at nal test pointspH values
40 C/75% RH
30 C/65% RH
25 C/60% RH
Final resultupright
position
Final resulthorizontal
position
7.53
7.42
7.46
7.44
7.40
7.40
748