CURRENT TRANSFORMERS

General Definitions
General definitions have been given according to International Standarts IEC 6OO44
6OO44.
Instrument Transformer
A transformer intended to supply measuring instruments meters, protection relays and other similiar apparatus.
Applicable Standards
Our transformers comply with applicable national and international standards.
Current Transformers
An instrument transformer in which the secondary current, in normal conditions of use
use, is substantially proportional to the primary
current and differs in phase from it by angle which is approximately zero for an appropriate direction of the connections.
It isolates the instrument and protection circuit from the primary side and protect the devices against overload according to the
overcurrent characteristics of the transformer. Current transformers can have several secondary windings with cores of identical of
different characteristics completely isolated from each other.
Measuring Current Transformer
A current transformer intended to supply indicating instruments, integrating meters and similiar apparatus.
Protective Current Transformer
A current transformer intended to supply protective relays.
Primary Winding
The winding through which flows the current to be transformed.
Secondary Winding
The winding, which supplies the current circuits of measuring instruments, meters, relays or similiar devices.
Secondary Circuit
The external circuit supplied by the secondary winding of a transformer.
Rated Primary Current
The value of the primary current on which the performance of the transformer is based.
Rated Secondary Current
The value of the secondary current on which the performance of the transformer is based.
Rated Transformation Ratio
The ratio of rated primary current to the rated secondary current (I1N/I2N-i.e.
(I1N I2N-i.e. 1OO/5A)
1OO 5A)
Current Error (Ratio Error)
The error which a transformer introduces into the measurement of a current and which arises from the fact that the actual
transformation ratio is not equal to the rated transformation ratio.
The current error expressed in per cent is given by formula:
Current Error % (Kn Is - Ip)
Where
Kn is the rated transformation ratio;
Ip is the actual primary current
Is is the actual secondary current when Ip is flowing under the conditions of measurements.

www.esitas.com
Accuracy Class
A designation assigned to a current transformer errors of which remain within specified limits under prescribed conditions of use.
Burden
The impedance of the secondary circuit in ohms and power-factor. The burden is usually expressed as the apparent power in
voltamperes absorbed at a specified power-factor and at the rated secondary current.
Rated Burden
The value of the burden on which the accuracy requirements are based on.
Rated Output
The value of the apparent power (in voltamperes at a specified power-factor) which the transformer is intended to supply to the
secondary circuit at the rated secondary current and with rated burden connected to it.
Rated Insulation Level
The combination of voltage values which characterizes the insulation of a transformer with regard to its capability to whitstand
dielectric stresses.
Rated Frequency
This is the frequency for which the transformer is designed and given in Hz on the rating plate.
Rated Short-Time Thermal Current (Ith)
The r.m.s. value of the primary current which a transformer will withstand for one second without suffering harmful effects
the secondary winding being short-circuited.
Rated Dynamic Current (ldyn)
The peak value of the primary current which a transformer will withstand without being damaged electrically or mechanically
by the resulting electromagnetic forces the secondary winding being short-circuited.
Rated Continuous Thermal Current
The value of the current which can be permitted to flow continuously in the primary winding the secondary winding being
connected to the rated burden without temperature rise exceeding the values specified.

CURRENT TRANSFORMERS
CONNECTION DIAGRAMS
Single Ratio Current Transformers
P1

P2

P1

S1

S2

1S1

Single Core

P2

1S2 2S1

3S2

2S2 3S1

Multi Cores

Reconnection of Current Transformer


In case of changeable ratios, it is possible to design the transformer with primary reconnection or secondary tapping;

Primary Reconnection

P1

C1

C2

P2

Changeover will be done at the primary


side by using joint bars.
Can be used only for primary currents up to 2 x 6OOA

S1

S2

C1 -C2 short circuited: low rated current


P1 - C1 and P2 - C2 short circuited: high rated current

Secondary Tapping
Changeover will be done at the secondary side.

P1

S1

P2

S2

S3

S1 -S2 low rated current


S1 - S3 high rated current

www.esitas.com
Safety Operation Conditions for Current Transformers
P1

- When the secondary terminals are connected to the measuring or protection devices
one of the terminals should be earthed for safety as seen in Diagram-1.

P2

Diagram-1
S1

S2
A

- The secondary circuit of a current transformer must not be operated with an open - circuit. P1
- The secondary winding of a current transformer which will not be used must
be short - circuited and earthed as seen in Diagram-2
Diagram-2

P2

S1

S2

P1

- For the transformer with reconnectable and - or tapped secondaries


unused terminals must be left open as seen in Diagram-3.

P2

Diagram-3
S1

S2
A

S3 open

- The current transformers which have capacitive divider tap (Ck) must be connected to the indicator if the tap will
not be used then it must be earthed.

M.V. CURRENT TRANSFORMERS CONNECTION CLEARENCES


a

Insulation Level
12kV
24kV
36kV

a minimum b minimum
1OOmm
19Omm
3O5mm

11Omm
21Omm
325mm

CURRENT TRANSFORMERS
INDOOR SUPPORT TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS
(Um=3,6kV .............. 12kV BLOCK TYPES)

- Up to 3 cores*
cores
- On request with capacitive layer.
- On request with barrier.

Technical Data
TYPES

ATB 1O-B2 ATB 1O-B3

ATB 1O-B

ATB 1O-2

Operating voltage, Um (kV)

3,6

7,2

12

Rated power-frequency withstand voltage (1 minute) (kV)

1O

2O

28

4O

6O

75

5O-6O

Rated frequency (Hz)

(On request 3OOOA 1.Oxln / Cont. &


Insulation class B )

Primary rated current (A)

5 - 25OO

Primary reconnection (A)

2 x 5 - 2 x 6OO
1-5

Secondary rated current (A)


Metering classes

O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1

Protection classes

5P- 1OP; CI:PX Acc. to IEC 6OO44-1


max. 1OOO x In

Rated short-time thermal current (lth) (1s) (kA)


Rated dynamic current (ldyn) (kA)

2,5 x lth

Short-time load (mechanical) (N)

5OOO
E

Insulation class

-25 ........... +4O**


+4O

Ambient temperature (C)

1OOO

Altitude (m)
Standard
Weight (approx.) (kg)

10

According to the customer requirements


2O - 25

28 - 33

33 - 36

36

On request operating voltage of 17,5 kV is available.


* For more cores please contact with ESITAS for feasibility.
** It can be produced according to customer's specified ambient temperature.Please contact with ESiTAS for feasibility.

www.esitas.com
INDOOR SUPPORT TYPE CAST RESIN INSULATED C.T.S TECHNICAL DRAWING
(Um=3,6kV .............. 12kV BLOCK TYPES)

TYPES
ATB
ATB
ATB
ATB
-

1O-B
1O-B2
1O-B3
1O-2

355 155 22O 148 29O 125 27O 2O


395 195 22O 148 33O 125 31O 2O
455 255 22O 148 39O 125 37O 2O

TIGHTENING TORQUE (Nm)

M5 (Secondary Terminal)
M8 (Ground Terminal)
M12 (Primary Terminal)

min. max.
2.5

3.5

15

2O

6O

7O

355 155 22O 175 29O 15O 27O 2O

All dimensions are in mm.


Tolerances are according to DIN 7168-g when not specified.
Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.
Customer designed products are also available.

11

CURRENT TRANSFORMERS
INDOOR SUPPORT TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS
(Um=3,6kV ...... 12kV, 17,5 ...... 24kV NEW BLOCK TYPES)

- Up to 3 cores*
cores
- On request with capacitive layer.
- On request with barrier.

Technical Data
TYPES

ATB 1O-BS

ATB 2O-BS

Operating voltage, Um (kV)

3,6

7,2

12

Rated power-frequency withstand voltage (1 minute) (kV)

1O

2O

4O

6O

**

17,5

24

28

38

5O

75

95

125

5O-6O

Rated frequency (Hz)

(On request 3OOOA 1.Oxln / Cont. &


Insulation class B )

Primary rated current (A)

5 - 25OO

Primary reconnection (A)

2 x 5 - 2 x 6OO
1-5

Secondary rated current (A)


Metering classes

O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1

Protection classes

5P- 1OP; CI:PX Acc. to IEC 6OO44-1


max. 1OOO x In

Rated short-time thermal current (lth) (1s) (kA)


Rated dynamic current (ldyn) (kA)

2,5 x lth

Short-time load (mechanical) (N)

5OOO
E

Insulation class

-25 ........... +4O***


+4O ***

Ambient temperature (C)

1OOO

Altitude (m)
Standard
Weight (approx.) (kg)

12

According to the customer requirements


2O - 25

3O

* For more cores please contact with ESITAS for feasibility.


** On request ATB 1O-BS operating voltage of 17,5kV is available.
*** It can be produced according to customer's specified ambient temperature.Please contact with ESITAS for feasibility.

www.esitas.com
INDOOR SUPPORT TYPE CAST RESIN INSULATED C.T.S TECHNICAL DRAWING
(Um=3,6kV ...... 12kV, 17,5 ...... 24kV NEW BLOCK TYPES)

8Omm will be
7Omm at
ATB1O-BS

TYPES
ATB 1O-BS
ATB 2O-BS
-

355 155 22O 148 299 135

G
-

125 27O 2O

355 155 28O 178 3OO 135 34O 15O 28O 2O

TIGHTENING TORQUE (Nm)

M5 (Secondary Terminal)
M8 (Ground Terminal)
M12 (Primary Terminal)

All dimensions are in mm.


Tolerances are according to DIN 7168-g when not specified.
Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.
Customer designed products are also available.

min. max.
2.5

3.5

15

2O

6O

7O

13

CURRENT TRANSFORMERS
INDOOR SUPPORT TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS
(Um=3,6kV .............. 12kV NARROW BLOCK TYPES)

Types: ATB 1O-1O


ATB 1O-15
-

ATB 1O-1O up to 1 core *


ATB 1O-15 up to 2 cores. *
On request with capacitive layer.
On request with barrier.

Technical Data
TYPES

ATB 1O-1O

ATB 1O-15

Operating voltage, Um (kV)

3,6

7,2

12

Rated power-frequency withstand voltage (1 minute) (kV)

1O

2O

28

4O

6O

75

5O-6O

Rated frequency (Hz)


Primary rated current (A)

5-up to 125O

Primary reconnection (A)

2x5- 2x6OO
1-5

Secondary rated current (A)


Metering classes

O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1

Protection classes

5P- 1OP; CI:PX Acc. to IEC 6OO44-1


(max. 2OO x In)**
In) **

Rated short-time thermal current (lth) (1s) (kA)


Rated dynamic current (ldyn) (kA)

2,5 x lth

Short-time load (mechanical) (N)

5OOO
E

Insulation class

-25 ........... +4O***


+4O ***

Ambient temperature (C)

1OOO

Altitude (m)
Standard
Weight (approx.) (kg)

14

According to the customer requirements


12

17

On request operating voltage of 17,5 kV is available.


* For more cores please contact with ESITAS for feasibility.
** May vary according to requested primary current and core values.
*** It can be produced according to customer's specified ambient temperature. Please contact with ESiTAS for feasibility.

www.esitas.com
INDOOR SUPPORT TYPE CAST RESIN INSULATED C.T.S
C.T. S TECHNICAL DRAWING
(Um=3,6kV .............. 12kV NARROW BLOCK TYPES)

TYPES
ATB 1O-1O
ATB 1O-15
-

33O 155 22O 148 125 27O 2O


33O 155 22O 148 125 27O 2O

TIGHTENING TORQUE (Nm)


M5 (Secondary Terminal)
M8 (Ground Terminal)
M12 (Primary Terminal)

All dimensions are in mm.


Tolerances are according to DIN 7168-g when not specified.
Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.
Customer designed products are also available.

min. max.
2.5

3.5

15

2O

6O

7O

15

CURRENT TRANSFORMERS
INDOOR SUPPORT TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS
(Um=17,5kV .............. 24kV BLOCK TYPES)

- Up to 3 cores.
cores.*
- On request with capacitive layer.
- On request with barrier.

Technical Data
TYPES

ATB 2O-B ATB 2O-B2 ATB 2O-B4 ATB 2O-3 ATB 2O-3B ATB 2O-3K

Operating voltage, Um (kV)

17.5

24

Rated power-frequency withstand voltage (1 minute) (kV)

38

5O

95

125
5O-6O

Rated frequency (Hz)

1.Oxln / Cont. &


5 - 25OO (On request 3OOOA
Insulation class B )

Primary rated current (A)

2 x 5 - 2 x 6OO

Primary reconnection (A)

1-5

Secondary rated current (A)


Metering classes

O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1

Protection classes

5P- 1OP; CI:PX Acc. to IEC 6OO44-1


max. 1OOO x In

Rated short-time thermal current (lth) (1s) (kA)


Rated dynamic current (ldyn) (kA)

2,5 x lth

Short-time load (mechanical) (N)

5OOO
E

Insulation class

-25 ........... +4O**


+4O

Ambient temperature (C)

1OOO

Altitude (m)

According to the customer requirements

Standard
Weight (approx.) (kg)

16

3O

42

44

44

55

7O

* For more cores please contact with ESITAS for feasibility.


** It can be produced according to customer's specified ambient temperature.Please contact with ESITAS for feasibility.

www.esitas.com
INDOOR SUPPORT TYPE CAST RESIN INSULATED C.T.S TECHNICAL DRAWING
(Um=17,5kV .............. 24kV BLOCK TYPES)

TYPES
ATB
ATB
ATB
ATB
ATB
ATB
-

2O-B
2O-B2
2O-B4
2O-3
2O-3B
2O-3K

355 155 28O 178 29O 145 15O 28O 2O


355 155 28O 2O5 29O 145 18O 28O 17
355 155 28O 218 29O 145 19O 28O 17

TIGHTENING TORQUE (Nm)

M5 (Secondary Terminal)
M8 (Ground Terminal)
M12 (Primary Terminal)

min. max.
2.5

3.5

15

2O

6O

7O

455 197 28O 178 39O 195 15O 375 22


455 197 28O 2O5 39O 195 18O 375 22
455 197 28O 218 39O 195 19O 375 22

All dimensions are in mm.


Tolerances are according to DIN 7168-g when not specified.
Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.
Customer designed products are also available.

17

CURRENT TRANSFORMERS
INDOOR SUPPORT TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS
(Um=17,5kV .............. 24kV NEW BLOCK TYPES)

Types: ATB 2O-3A


ATB 2O-3B

- Up to 3 cores.*
cores.
- On request with capacitive layer.
- On request with barrier.

Technical Data
TYPES

ATB 2O-3A

ATB 2O-3B

Operating voltage, Um (kV)

17.5

24

Rated power-frequency withstand voltage (1 minute) (kV)

38

5O

95

125

5O-6O

Rated frequency (Hz)

1.Oxln / Cont. &


5 - 25OO (On request 3OOOA
Insulation class B )

Primary rated current (A)

2 x 5 - 2 x 6OO

Primary reconnection (A)

1-5

Secondary rated current (A)


Metering classes

O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1

Protection classes

5P- 1OP; CI:PX Acc. to IEC 6OO44-1


max. 1OOO x In

Rated short-time thermal current (lth) (1s) (kA)


Rated dynamic current (ldyn) (kA)

2,5 x lth

Short-time load (mechanical) (N)

5OOO
E

Insulation class

-25 ........... +4O**


+4O

Ambient temperature (C)

1OOO

Altitude (m)
Standard
Weight (approx.) (kg)

18

According to the customer requirements


44

55

* For more cores please contact with ESITAS for feasibility.


** It can be produced according to customer's specified ambient temperature.Please contact with ESITAS for feasibility.

www.esitas.com
INDOOR SUPPORT TYPE CAST RESIN INSULATED C.T.S TECHNICAL DRAWING
(Um=17,5kV .............. 24kV NEW BLOCK TYPES)

TYPES
ATB 2O-3A
ATB 2O-3B
-

455 28O 178 39O 14O 15O 375 2O


455 28O 2O5 39O 14O 18O 375 2O

TIGHTENING TORQUE (Nm)


M5 (Secondary Terminal)
M8 (Ground Terminal)
M12 (Primary Terminal)

All dimensions are in mm.


Tolerances are according to DIN 7168-g when not specified.
Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.
Customer designed products are also available.

min. max.
2.5

3.5

15

2O

6O

7O

19

CURRENT TRANSFORMERS
INDOOR SUPPORT TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS
(Um=17,5kV .............. 24kV NARROW BLOCK TYPES)

Types: ATB 2O-1O


ATB 2O-15

ATB 2O-1O up to
ATB 2O-15 up to
On request with
On request with

1 core
core*
cores.
2 cores.*
capacitive layer.
barrier.

Technical Data
TYPES

ATB 2O-1O

ATB 2O-15

Operating voltage, Um (kV)

17.5

24

Rated power-frequency withstand voltage (1 minute) (kV)

38

5O

95

125

5O-6O

Rated frequency (Hz)


Primary rated current (A)

5 up to 125O

Primary reconnection (A)

2 x 5 - 2 x 6OO
1-5

Secondary rated current (A)


Metering classes

O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1

Protection classes

5P- 1OP; CI:PX Acc. to IEC 6OO44-1


(max. 3OO x In)**
In) **

Rated short-time thermal current (lth) (1s) (kA)


Rated dynamic current (ldyn) (kA)

2,5 x lth

Short-time load (mechanical) (N)

5OOO
E

Insulation class

-25 ........... +4O***


+4O ***

Ambient temperature (C)

1OOO

Altitude (m)
Standard
Weight (approx.) (kg)

20

According to the customer requirements


22

3O

* For more cores please contact with ESITAS for feasibility.


** May vary according to requested primary current and core values.
*** It can be produced according to customer's specified ambient temperature.Please contact with ESITAS for feasibility.

www.esitas.com
INDOOR SUPPORT TYPE CAST RESIN INSULATED C.T.S TECHNICAL DRAWING
(Um=17,5kV .............. 24kV NARROW BLOCK TYPES)

TYPES
ATB 2O-1O
ATB 2O-15
-

335 155 28O 178 15O 28O 2O


335 155 28O 178 15O 28O 2O

TIGHTENING TORQUE (Nm)


M5 (Secondary Terminal)
M8 (Ground Terminal)
M12 (Primary Terminal)

All dimensions are in mm.


Tolerances are according to DIN 7168-g when not specified.
Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.
Customer designed products are also available.

min. max.
2.5

3.5

15

2O

6O

7O

21

CURRENT TRANSFORMERS
INDOOR SUPPORT TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS
(Um=36kV BLOCK TYPES)

- Up to 3 cores.
cores.*
- On request with capacitive layer.
- On request with barrier.

Technical Data
TYPES

ATB 3O-S

ATB 3O-S1

ATB 3O-1

Operating voltage, Um (kV)

36

Rated power-frequency withstand voltage (1 minute) (kV)

7O

ATB 3O-2

ATB 3O-3

17O
5O-6O

Rated frequency (Hz)

1.Oxln / Cont. &


5 - 25OO (On request 3OOOA
Insulation class B )

Primary rated current (A)

2 x 5 - 2 x 6OO

Primary reconnection (A)

1-5

Secondary rated current (A)


Metering classes

O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1

Protection classes

5P- 1OP; CI:PX Acc. to IEC 6OO44-1


max. 1OOO x In

Rated short-time thermal current (lth) (1s) (kA)


Rated dynamic current (ldyn) (kA)

2,5 x lth

Short-time load (mechanical) (N)

5OOO
E

Insulation class

-25 ........... +4O**


+4O

Ambient temperature (C)

1OOO

Altitude (m)

According to the customer requirements

Standard
Weight (approx.) (kg)

22

35

37

4O

46

51

* For more cores please contact with ESITAS for feasibility.


** It can be produced according to customer's specified ambient temperature.Please contact with ESITAS for feasibility.

www.esitas.com
INDOOR SUPPORT TYPE CAST RESIN INSULATED C.T.S TECHNICAL DRAWING
(Um=36kV BLOCK TYPES)

TYPES
ATB
ATB
ATB
ATB
ATB
-

3O-S
3O-S1
3O-1
3O-2
3O-3

385 17O 36O 255 25O 125 21O 225 3OO 2O


385 17O 36O 255 27O 135 22O 225 3OO 2O TIGHTENING TORQUE (Nm)

min. max.

385 17O 36O 255 27O 135 22O 225 3OO 2O

2.5

3.5

15

2O

6O

7O

M5 (Secondary Terminal)
385 17O 36O 255 31O 155 24O 225 3OO 2O M8 (Ground Terminal)
455 21O 36O 255 389 195 249 225 375 2O M12 (Primary Terminal)

All dimensions are in mm.


Tolerances are according to DIN 7168-g when not specified.
Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.
Customer designed products are also available.

23

CURRENT TRANSFORMERS
INDOOR SUPPORT TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS
(Um=36kV NARROW BLOCK TYPES)

ATB 3O-4 , 3O-5 , 3O-1O up to 1 core.


core.*
cores.**
ATB 3O-15 up to 2 cores.
On request with capacitive layer.
ATB 3O-1O & ATB 3O-15 with barrier on request.

Technical Data
TYPES

ATB 3O-4

ATB 3O-5

ATB 3O-1O

Operating voltage, Um (kV)

36

Rated power-frequency withstand voltage (1 minute) (kV)

7O

ATB 3O-15

17O
5O-6O

Rated frequency (Hz)


Primary rated current (A)

5 - up to 6OO

5 - up to 125O

Primary reconnection (A)

2x5 - 2x3OO

2x5 - 2x6OO
1-5

Secondary rated current (A)


Metering classes

O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1

Protection classes

5P- 1OP; CI:PX Acc. to IEC 6OO44-1

Rated short-time thermal current (lth) (1s) (kA)

max. 3OOxIn
3OOxIn** max. 4OOxIn
4OOxIn** max. 8OOxIn
8OOxIn** max. 3OOxIn**
3OOxIn
(for 1
measurement
core)

(for 1
measurement
core)

(for 1
measurement
core)

Rated dynamic current (ldyn) (kA)

2,5 x lth

Short-time load (mechanical) (N)

5OOO
E

Insulation class

-25 ........... +4O***


+4O ***

Ambient temperature (C)

1OOO

Altitude (m)
Standard
Weight (approx.) (kg)

24

(for 2 cores)

According to the customer requirements


2O

22

25

35

* For more cores please contact with ESITAS for feasibility.


** May vary according to requested primary current and core values.
*** It can be produced according to customer's specified ambient temperature.Please contact with ESITAS for feasibility.

www.esitas.com
INDOOR SUPPORT TYPE CAST RESIN INSULATED C.T.S TECHNICAL DRAWING
(Um=36kV NARROW BLOCK TYPES)

TYPES
ATB
ATB
ATB
ATB
-

3O-4
3O-5
3O-1O
3O-15

385 17O 36O 255 2OO 1OO 18O 225 3OO 2O


385 17O 36O 255 25O 125 21O 225 3OO 2O
385 17O 36O 255 25O 125 21O 225 3OO 2O

TIGHTENING TORQUE (Nm)

M5 (Secondary Terminal)
M8 (Ground Terminal)
M 12 (Primary Terminal)

min. max.
2.5

3.5

15

2O

6O

7O

385 17O 36O 255 25O 125 21O 225 3OO 2O

All dimensions are in mm.


Tolerances are according to DIN 7168-g when not specified.
Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.
Customer designed products are also available.

25

CURRENT TRANSFORMERS
INDOOR SUPPORT TYPE CAST RESIN INSULATED NARROW TYPE CURRENT TRANSFORMERS
(Um=7,2kV .......... 24kV BLOCK TYPES)

Types: ATU 24

- Up to 2 cores.

Technical Data
TYPES

ATU 24

Operating voltage, Um (kV)

7,2

12

Rated power-frequency withstand voltage (1 minute) (kV)

2O

28

6O

75

17,5

24

38

5O

95

125

5O-6O

Rated frequency (Hz)


Primary rated current (A)

1O - up to 8OO

Primary reconnection (A)

2x1O - 2x4OO

Secondary rated current (A)

1-5
O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1

Metering classes

5P- 1OP Acc. to IEC 6OO44-1

Protection classes
Rated short-time thermal current (lth) (1s) (kA)

1OO x In*
In

Rated dynamic current (ldyn) (kA)

2,5 x lth

Short-time load (mechanical) (N)

5OOO
E

Insulation class
Ambient temperature (C)
Altitude (m)
Standard
Weight (approx.) (kg)

26

-25............+4O**
-25............+4O
**
1OOO
According to the customer requirements
24

* May vary according to requested primary current and core values.


** It can be produced according to customers specified ambient temperature. Please contact with ESITAS for feasibility.

www.esitas.com
INDOOR SUPPORT TYPE CAST RESIN INSULATED NARROW TYPE C.T.S
TECHNICAL DRAWING
(Um=7,2kV .......... 24kV BLOCK TYPES)

All dimensions are in mm.


Tolerances are according to DIN 7168-g when not specified.
Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.
Customer designed products are also available.

27

CURRENT TRANSFORMERS
INDOOR SUPPORT TYPE CAST RESIN INSULATED SPECIAL TYPE
CURRENT TRANSFORMERS
(Um=7,2kV .......... 24kV BLOCK TYPES)
PES)
Types: ES24 C3-B

- Up to 2 cores.

Technical Data
TYPES

ES24 C3-B

Operating voltage, Um (kV)

7,2

12

Rated power-frequency withstand voltage (1 minute) (kV)

2O

28

6O

75

17,5

24

38

5O

95

125

5O-6O

Rated frequency (Hz)


Primary rated current (A)

1O - up to 8OO

Primary reconnection (A)

2x1O - 2x4OO

Secondary rated current (A)

1-5
O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1

Metering classes

5P-1OP-PX Acc. to IEC 6OO44-1

Protection classes
Rated short-time thermal current (lth) (1s) (kA)

Up to 6OkA*
6OkA

Rated dynamic current (ldyn) (kA)

2,5 x lth

Short-time load (mechanical) (N)

5OOO
E

Insulation class
Ambient temperature (C)
Altitude (m)
Standard
Weight (approx.) (kg)

28

-25............+4O**
-25............+4O
1OOO
According to the customer requirements
25

* May vary according to requested primary current and core values.


** It can be produced according to customers specified ambient temperature. Please contact with ESITAS for feasibility.

www.esitas.com
INDOOR SUPPORT TYPE CAST RESIN INSULATED SPECIAL TYPE C.T.S
TECHNICAL DRAWING
(Um=7,2kV .......... 24kV BLOCK TYPES)

All dimensions are in mm.


Tolerances are according to DIN 7168-g when not specified.
Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.
Customer designed products are also available.

29

CURRENT TRANSFORMERS
INDOOR POST BUSBAR TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS
(Um=3,6kV ....................24kV)

- Up to 2 cores.*
cores.

Technical Data
TYPES

ATD 1O

Operating voltage, Um (kV)

3,6

7,2

Rated power-frequency withstand voltage (1 minute) (kV)

1O
4O

ATD 2O
12

17,5

24

2O

28

38

5O

6O

75

95

125

5O-6O

Rated frequency (Hz)

8OO-3OOO

Primary rated current (A)

8OO-4OOO
1-5

Secondary rated current (A)


Metering classes

O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1

Protection classes

5P- 1OP; CI:PX Acc. to IEC 6OO44-1


max. 1OO

Rated short-time thermal current (lth) (1s) (kA)

Practically Unlimited

Rated dynamic current (ldyn) (kA)

3OOO

Short-time load (mechanical) (N)

Insulation class

-25 ........... +4O**


+4O

Ambient temperature (C)

1OOO

Altitude (m)
Standard
Weight (approx.) (kg)

30

According to the customer requirements


19

34

* For more cores please contact with ESITAS for feasibility.


** It can be produced according to customer's specified ambient temperature.Please contact with ESITAS for feasibility.

www.esitas.com
INDOOR POST BUSBAR TYPE CAST RESIN INSULATED C.T.S TECHNICAL DRAWING
(Um=3,6kV ..............24kV)

TYPES
ATD 1O
ATD 2O
-

28O 1O2 342 214 215 235 158 155 23

TIGHTENING TORQUE (Nm)

M5 (Secondary Terminal)

min. max.
2.5

3.5

28O 1O2 427 26O 26O 295 158 155 23

All dimensions are in mm.


Tolerance is DIN 7168-g .
Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.
Customer designed products are also available.

31

CURRENT TRANSFORMERS
INDOOR POST BUSBAR TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS
(Um=3,6kV............24kV)

- Up to 3 cores.
cores.*

Technical Data
TYPES

ATN 17

ESO 17C

Operating voltage, Um (kV)

3,6

7,2

Rated power-frequency withstand voltage (1 minute) (kV)

1O

2O

4O

6O

12

ATN 24

17,5

17,5

24

28

38

38

5O

75

95

95

125

5O-6O

Rated frequency (Hz)

8OO-4OOO

Primary rated current (A)

1-5

Secondary rated current (A)


Metering classes

O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1

Protection classes

5P- 1OP; CI:PX Acc. to IEC 6OO44-1


max. 1OO

Rated short-time thermal current (lth) (1s) (kA)

Practically Unlimited

Rated dynamic current (ldyn) (kA)

3OOO

Short-time load (mechanical) (N)

Insulation class

-25 ........... +4O**


+4O

Ambient temperature (C)

1OOO

Altitude (m)
Standard
Weight (approx.) (kg)

32

According to the customer requirements


35

4O

38

* For more cores please contact with ESITAS for feasibility.


** It can be produced according to customer's specified ambient temperature.Please contact with ESITAS for feasibility.

www.esitas.com
INDOOR POST BUSBAR TYPE CAST RESIN INSULATED C.T.S TECHNICAL DRAWING
(Um=3,6kV............24kV)
ATN 17 (width 15Omm )

ATN 24

TIGHTENING TORQUE (Nm)

M5 (Secondary Terminal)
-

ATN 17 (width 28Omm )

ESO 17C

min. max.
2,5 3,5

All dimensions are in mm.


Tolerance is DIN 7168-g.
Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.
Customer designed products are also available.

33

CURRENT TRANSFORMERS
OUTDOOR DRY TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS
(Um=3,6kV ....................24kV)

- ATH 2O up to 1 core.*
core.
cores.
- ATH 21 up to 2 cores.*
cores.
- ATH 22 up to 3 cores.*

For the connection


of aluminium conductors
steel reinforced

Technical Data
TYPES

ATH 2O

ATH 21

ATH 22

Operating voltage, Um (kV)

3,6

7,2

12

17,5

24

Rated power-frequency withstand voltage (1 minute) (kV)

1O

2O

28

38

5O

4O

6O

75

95

125

5O-6O

Rated frequency (Hz)


Primary rated current (A)

5-125O

Primary reconnection (A)

5-25OO
2x5 - 2x4OO

2x5 - 2x6OO
1-5

Secondary rated current (A)


Metering classes

O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1

Protection classes

5P- 1OP; CI:PX Acc. to IEC 6OO44-1


max. 1OOO x In

Rated short-time thermal current (lth) (1s) (kA)


Rated dynamic current (ldyn) (kA)

2,5 x lth

Short-time load (mechanical) (N)

24OO
E

Insulation class
Min. creepage distance (mm)

56O

Altitude (m)

According to the customer requirements

Standard

According to the customer requirements

Weight (approx.) (kg)

34

24

825

35

77O

78

* For more cores please contact with ESITAS for feasibility.

www.esitas.com
OUTDOOR DRY TYPE CAST RESIN INSULATED C.T.S TECHNICAL DRAWING
(Um=3,6kV ....................24kV)

TYPES
ATH 2O
ATH 21
ATH 22

245 1O5
35O 165
4OO 195

C
max.
35O
max.
37O
max.
38O

22O

max.
225
max.
34O
max.
415

3OO
37O

178 175 2O

TIGHTENING TORQUE (Nm)

27O 2OO 65

M6 (Secondary Terminal)
M12 (Primary & Ground Terminal)

34O 25O 7O

- All dimensions are in mm.


- Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.
- Customer designed products are also available.

min. max.
3

6O 7O

35

CURRENT TRANSFORMERS
OUTDOOR DRY TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS
(Um=36kV)
Types: ATH 3O
ATH 32

- ATH 3O up to 2 cores.*
cores.
cores.
- ATH 32 up to 3 cores.*
For the connection
of aluminium conductors
steel reinforced

Technical Data
TYPES

ATH 3O

ATH 32

Operating voltage, Um (kV)

36

Rated power-frequency withstand voltage (1 minute) (kV)

7O
17O
5O-6O

Rated frequency (Hz)


Primary rated current (A)

5-25OO

Primary reconnection (A)

2x5 - 2x6OO
1-5

Secondary rated current (A)


Metering classes

O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1

Protection classes

5P- 1OP; CI:PX Acc. to IEC 6OO44-1


max. 1OOO x In

Rated short-time thermal current (lth) (1s) (kA)


Rated dynamic current (ldyn) (kA)

2,5 x lth

Short-time load (mechanical) (N)

25OO
E

Insulation class

114O

Min. creepage distance (mm)


Altitude (m)

According to the customer requirements

Standard

According to the customer requirements

Weight (approx.) (kg)

36

47

85

* For more cores please contact with ESITAS for feasibility.

www.esitas.com
OUTDOOR DRY TYPE CAST RESIN INSULATED C.T.S TECHNICAL DRAWING
(Um=36kV)

TYPES
ATH 3O
ATH 32

35O 165
39O 19O

C
max.
465
max.
477

3OO

max.
34O
max.
4O3

35O

27O 2OO 65
32O 25O 65

TIGHTENING TORQUE (Nm)

M6 (Secondary Terminal)
M12 (Primary & Ground Terminal)

- All dimensions are in mm.


- Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.
- Customer designed products are also available.

min. max.
3

6O 7O

37

CURRENT TRANSFORMERS
OUTDOOR DRY TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS
(Um=36kV)

Types: ATH 3O-N


ATH 32-N

- ATH 3O-N up to 2 cores.*


cores.
- ATH 32-N up to 3 cores.
cores.*
Technical Data

For the connection


of aluminium conductors
steel reinforced

TYPES

ATH 3O-N

ATH 32-N

Operating voltage, Um (kV)

36

Rated power-frequency withstand voltage (1 minute) (kV)

7O
17O
5O-6O

Rated frequency (Hz)


Primary rated current (A)

5-25OO

Primary reconnection (A)

2x5 - 2x6OO
1-5

Secondary rated current (A)


Metering classes

O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1

Protection classes

5P- 1OP; CI:PX Acc. to IEC 6OO44-1


max. 1OOO x In

Rated short-time thermal current (lth) (1s) (kA)


Rated dynamic current (ldyn) (kA)

2,5 x lth

Short-time load (mechanical) (N)

25OO
E

Insulation class

114O

Min. creepage distance (mm)


Altitude (m)

According to the customer requirements

Standard

According to the customer requirements

Weight (approx.) (kg)

38

47

85

* For more cores please contact with ESITAS for feasibility.

www.esitas.com
OUTDOOR DRY TYPE CAST RESIN INSULATED C.T.S TECHNICAL DRAWING
(Um=36kV)

TYPES

ATH 3O-N 35O 165


ATH 32-N 39O 173

C
max.
465
max.
474

3OO

max.
34O
max.
4OO

35O

27O 2OO 65
32O 25O 65

TIGHTENING TORQUE (Nm)

M6 (Secondary Terminal)
M12 (Primary Terminal
Terminal)

- All dimensions are in mm.


- Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.
- Customer designed products are also available.

min. max.
3

6O 7O

39

CURRENT TRANSFORMERS
OUTDOOR DRY TYPE CAST RESIN INSULATED CURRENT TRANSFORMERS
(Um=52kV)

Types: ATH 52

- Up to 2 cores.*
cores.

Technical Data

For the connection


of aluminium conductors
steel reinforced

TYPES

ATH 52

Operating voltage, Um (kV)

52

Rated power-frequency withstand voltage (1 minute) (kV)

95
25O

Rated frequency (Hz)

5O-6O

Primary rated current (A)

5-25OO

Primary reconnection (A)

2x5 - 2x6OO

Secondary rated current (A)

1-5

Metering classes

O,2 - O,2S - O,5 - O,5S - 1 - 3 - 5 Acc. to IEC 6OO44-1

Protection classes

5P- 1OP; CI:PX Acc. to IEC 6OO44-1

Rated short-time thermal current (lth) (1s) (kA)

max. 1OOO x In

Rated dynamic current (ldyn) (kA)

2,5 x lth

Short-time load (mechanical) (N)

25OO

Insulation class
Min. creepage distance (mm)

E
16OO

Altitude (m)

According to the customer requirements

Standard

According to the customer requirements

Weight (approx.) (kg)

40

14O

* For more cores please contact with ESITAS for feasibility.

www.esitas.com
OUTDOOR DRY TYPE CAST RESIN INSULATED C.T.S TECHNICAL DRAWING
(Um=52kV )

TIGHTENING TORQUE (Nm)

M6 (Secondary Terminal)
M12 (Primary & Ground Terminal)
- All dimensions are in mm.
- Esitas reserves the right to change the specifications and the dimensions of the goods. Please ask for updated information.
- Customer designed products are also available.

min. max.
3

6O 7O

41

S-ar putea să vă placă și