Typical Applications
Raw Potable Water
Finsihed PotableWater
Highenduringaccuracyof
0.75%ofactualflowrate
(Uncalibrated)
Engineering Specification
The metering design shall be a differential
pressure producing type, utilizing corner Tap
static pressure at the inlet & pure static pressure
sensed at the throat. The differential pressure
shall indicate static pressure change only.
The 20182 Universal Venturi Tube has three
sections: A sharply angled conical section
followed by a 7 throat cone, these inlet sections
give the UVT it short laying length,
Asharplyangledconical
sectionfollowedbya7
throatconegivethisUVT
itsshortlayinglength.
The throat section shall be a cylindrical section
with a length at least 0.50 times the throat
diameter. The low-pressure tap shall be
installed in the throat section.
The pressure recovery section (outlet cone)
shall be truncated and have an included angle of
10 degrees. This truncated recovery section
accounts for the low head loss exhibited by the
Model 20182 Insert.
High metering accuracy of 0.75% of actual flow
rate (Uncalibrated), or to 0.25% with factory
available flow laboratory calibration
HighMeteringaccuracyof
0.75%ofactualflowrate
(Uncalirated).
TheSubstantiationshall
showthatthedischarge
coefficient2times
standarddeviationisno
greaterthan0.75%
Effects of upstream piping configuration shall be
known and based on testing performed by a
recognized hydraulic laboratory.
INLET
PIPEDIA
"D"
10
12
14
16
18
20
24
THROAT
DIA"d"
CLEARANCE
MODEL
1.800
2.400
2.900
2.700
3.600
4.350
3.600
4.800
5.800
4.800
5.800
7.250
5.800
7.250
8.700
6.300
8.700
10.150
7.250
10.150
11.600
8.700
10.150
13.050
10.150
11.600
14.500
11.600
14.500
17.400
L
APART
2018204
11
7/8
90
2018206
12
7/8
45
2018208
15
7/8
45
2018210
17
7/8
30
2018212
10
20
7/8
30
2018214
12
23
7/8
30
2018216
13
25
7/8
45
2018218
14
29
7/8
45
2018220
16
32
7/8
36
2018224
16
38
7/8
36
T Dimension does not include gasket thickness or pipe flange raised face dimensions
** A Dimension is manufacturers recommended upstream spool length
** B Dimension is manufacturers recommended downstream spool length.
Finish Derakane Gel Coat Light Grey with Red Flow Directional Arrow on Recovery Cone