Documente Academic
Documente Profesional
Documente Cultură
Introduction
Calculation of area and volumes
Chain Surveying
Plane table Surveying
Tacheometry or Stadia Surveying
Introduction of photogrammetry
CHAIN SURVEYING
Errors in Chaining:
If the length of the chain used in measuring length of the line
is not equal to the true length of the designated length, the
measured length of the line will not be correct and suitable
correction will have to be applied.
The error may also be either cumulative or compensating.
Cumulative error:
Cumulative errors are those which may either go on
increasing or decreasing when a chain is shorter or longer
than its standard length.
Cumulative error:
When the chain is too short, the measured length of the
line is too great i.e., greater than its true length and
therefore, the error is positive and the correction is
negative.
Again when the chain is too long, the measured distance
will be less, the error is negative and the correction is
positive.
Compensating errors:
Compensating errors are those which cancel one another
Compensating errors:
Again one may stretch it with a greater pull than the
Correction
Correction in length area and volume:
Let,
Le be the incorrect length of the chain and
Lc be the corrected length of the chain.
The correct distance,
The correct area,
The correct volume,
Example: The road from Dhaka to Mirpur is actually 25320 ft. long. This
distance was measured by an Engineers defective chain and was found to be
25270 ft. How much correction does the chain need?
Solution:
Correct distance, L = 25320 ft
Measured lenghth = 25270 ft
Corrected length of the chain, Lc = 100 ft
Incorrect length of the chain = Le
measured incorrect length
Example: The length and width of a plot of land were measured by an Engineer's chain
exactly 100 ft. in length at the beginning. But it was found to be 100.3 ft. long at the end of
the survey work. The area of the plot drawn to a scale 1 inch = 100 ft. was 25.60 sq. inches.
What was the true area of the plot?
Solution:
Corrected length of the chain, Lc = 100 ft
Incorrect length, Le = 100.3 ft
Example: The length, width and depth of a pond were measured 63.8 ft by an
incorrect Gunter's chain. The volume of the pond was calculated to be 1,60,000
cft. The chain was tested at the end of the measurement of the tank. 65.8
chain was standardized, the length of the tape increases, measured distance
becomes less and therefore the correction becomes additive.
On the other hand it is negative.
= ( 0 )
Where,
= co-efficient of thermal expansion.
Tm =Mean temperature in the field during measurement.
To =The standard temperature for the tape.
L =Measured length.
The co-efficient of thermal expansion of steel varies from 5.5x10-6 to
6.85x10-6 per degree oF. The sign of the correction is plus or minus according
as Tm greater or less than To . The steel tapes are generally standardized at
65F.
Example: A distance of 1840 ft. was measured with a steel tape which was
exactly 100 ft, long at 65F. The temperature during measurement in the
field was 85F. Calculate the actual length of the line. Take the co-efficient
of thermal expansion of tape =6.25xl0-6 per I'-'F.
First Method :
Second Method :
Total correction = 6.25x10-6 (8565)x1840 = 0.230 ft.
True length of the line= 1840+0.230 = 1840.230 ft.
Example: A steel tape of 100 ft. length, standardized at 25 lb. pull, was used in
the field with a pull of 35 lbs. The cross-sectional area of the tape is 0.025
sq. inch. Take the value of Young's Modulus of Elasticity for steel, 30xl06
psi. Calculate the correction for excess pull.
Example: A steel tape of 100 ft. length weighing 1.2lbs. was pulled with a force of 20
lbs. in the field to measure a certain distance. Calculate the correction for sag.
Problem
A steel tape 20m long standardized at 55F with a pull of 10Kg was used for measuring
a base line. Find the correction per meter length, if the temperature at that time of
measurement was 80F and the pull exerted was 16Kg. Weight of 1 cubic cm of
steel = 7.86 gm. Weight of tape = 0.8Kg and E = 2.109x106 Kg/cm2. Co-efficient of
expansion of tape per one foot is 6.25 x10-6 .
Solution:
1. Correction for temperature, Ct= ((Tm To) L
=6.25 x10-6(80-55) 20
=0.0031 m. (Additive)
Thank You