Documente Academic
Documente Profesional
Documente Cultură
sysconfig -A
sysconfig r
environment status
rdfile /etc/messages
(CLUSTER ERROR: DISK/SHELF COUNT MISMATCH) ERROR
Disk: 2b.02.8
Shelf: 2
Bay: 8
Serial: 9QJ7KBHQ
Vendor: NETAPP
Model: X302_SMOOS01TSSM
Rev: NA06
RPM: 7200
WWN: 5:006:05ba00:10ad2c
Disk: 2b.02.11
Shelf: 2
Bay: 11
Serial: 9QJ7M8ZC
Vendor: NETAPP
Model: X302_SMOOS01TSSM
Rev: NA06
RPM: 7200
WWN: 5:006:05ba00:10ace4
Disk: 2b.02.22
Shelf: 2
Bay: 22
Serial: 9QJ7M5F3
Vendor: NETAPP
Model: X302_SMOOS01TSSM
Rev: NA06
RPM: 7200
WWN: 5:006:05ba00:10ad98
After a disk is added or removed from a controller, cluster monitor will automat
ically update the configuration status. Typically, this will take between 7 and
30 seconds. If mismatch messages persist, perform the following steps:
Set the option disk.auto_assign to off on both the nodes.
Reassign the disk to the appropriate node.
If the above steps do not help resolve the issue, perform the following:
Reseat the disk.
If reseating does not help, replace the disk with a known good spare disk.
If the spare disk shows up in the slot, then request for a replacement disk.
If the spare disk does not show up, then the issue could be with the shelf.
Replace the shelf.
Note: Before performing this step, halt both the heads of the cluster.
Also, try reseating the modules and see if it fixes the issue.