Sunteți pe pagina 1din 16

BILL OF QUANTITIES

GODOWN

SUMMARY OF BILLS OF QUANTITIES


GODOWN

Bill No

Description

BILL No: 01 - PRELIMINARIES

BILL No: 02 - GROUND WORKS

BILL No: 03 - CONCRETE

BILL No: 04 - MASONRY AND PLASTERING

BILL No: 05 - STRUCTURAL STEEL WORKS

BILL No: 06 - METALWORK

BILL No: 07 - CLADDING WORKS

BILL No: 08 - ROOF WORKS

BILL No: 09 - WOOD WORKS

10

BILL No: 10 - DOOR & WINDOW

11

BILL No: 11 - PAINT WORKS

12

BILL No: 12 - FINISHES

13

BILL No: 13 - HYDRAULICS AND DRAINAGE

14

BILL No: 14 - ELECTRICAL INSTALLATIONS

15

BILL No: 15- LIFT & HOISTS

16

BILL No: 16- ADDITIONS AND OMMISIONS

Amount

SUB TOTAL carried to form of bid

Riyan (Pvt) Ltd

IBM GODOWN

Item

Description
BILL No: 01 - PRELIMINARIES

Unit

Qty

Rate

Amount

1.1 GENERAL NOTES


1.1.1 Abbreviations
m - meter
No - numbers
m - cubic meter
m - square meter
Lm - Linear meter
t - tonnes
incl - including
mm - millimeter
SS - Stainless Steel
GI - Galvanized Iron
1.2 SITE MANAGEMENT COSTS
(1) Allow for all on and off site management cost including costs of
foreman and assistants, temporary services, telephone, fax,
hoardings and similar

item

1.00

1.3 SIGN BOARD


(1) Allow for sign board

No

1.00

1.4 SITE PREPARATION


(1) Demolition and disposal of existing building

item

1.00

1.5 CLEAN-UP
(1) Allow for clean-up upon completion of the works.

item

1.00

TOTAL OF BILL No: 01 - Carried over to summary

3/10/2011

Page 1of 14

Riyan Pvt Ltd

IBM GODOWN

Item

Description
BILL No: 02 - GROUND WORKS

Unit

Qty

Rate

Amount

2.1 GENERAL
(a) Rates shall include for: leveling, grading, trimming,
compacting to faces of excavation, keep sides plumb, backfilling,
consolidating and disposing surplus soil.
2.2 DEMOLISION
(a) Removing of Exsisting Single storey building (Nearly 5m
high) and removing of all the demolished material away from the
site.

item

1.00

2.3 SITE CLEARING


Clear the area of site from rubbish and vegetable matters,
stumps, roots.

529.09

2.4 EXCAVATION
Excavation quantities are measured to the faces of concrete
members. Rates shall include for all additional excavation
required to place the formwork.
2.4.1 Excavation for foundations
(1) Foundation raft and Plinth beams

42.73

2.5 FILLING
Rates shall include for: leveling, grading, trimming, compacting
and similar.
(1) Compacted earth filling under ground screed
(2) 10mm thick blinding

m
m

104.16
529.09

2.6 DAMPPROOF MEMBRANE


Rate shall include for: dressing around and sealing to all
penetrations
(1) Polythene damp proof membrane under ground floor screed

529.09

TOTAL OF BILL No: 02 - Carried over to summary

3/10/2011

Page 2of 14

Riyan Pvt Ltd

IBM GODOWN

Item

Description
BILL No: 03 - CONCRETE

Unit

Qty

Rate

Amount

3.1 GENERAL
(a) Rates shall include for: placing in position; making good
after removal of formwork, mortar touch up to all concrete and
casting in all required items; additional concrete required to
conform to structural and excavated tolerances.
(b) Mix ratio for reinforced concrete shall be 1:2:3 and lean
concrete shall be 1:2:6
(1) Allow for concrete testing
3.2 LEAN CONCRETE
(a) Quantity is measured to the edges of concrete foundation
members. Rates shall be inclusive for any additional concrete
required to place the formwork.
50mm thick lean concrete to foundations
(1) Under footings & Plinth beams (50mm thk)

3.3 REINFORCED CONCRETE


(a) Rates shall include for: concrete, formwork, reinforcement,
cleaning, fabrication, placing, the provision for all necessary
temporary fixings, and supports including tie wire and chair
supports, laps, distribution bars and wastage
(b) Rates shall include for: all necessary boarding, supports,
erecting, framing, temporary cambering, cutting, perforations for
reinforcing bars, bolts, straps, ties, hangers, pipes and removal of
formwork.
(c) Rates shall include for: cleaning, fabrication, placing, the
provision for all necessary temporary fixings, and supports
including tie wire and chair supports, laps, distribution bars and
wastage
(d) All reinforcing bars shall be high strength bars
(e) Slab soffits to be finished fairfaced, use plasticizer and
formwork with reducing agent.
(a) Waterproofing shall be added to all concrete below ground
level
In-situ reinforced concrete to:
3.3.1 FOUNDATION & COLUMNS UPTO GROUND LEVEL
(1) Foundation pad P1, 1300x1300x300
(2) Foundation pad P2, 1400x700x300
(3) Foundation pad P3, 1000x1000x300
(4) Foundation pad P4, 500x500x300
(5) Foundation pad P4, 1800x900x300
(6) Foundation beam TB, 200x250
(7) RC stud, 1.10m long (270x450mm)
a. (floor slab Finished with power toweled surface to semi rough
finish)
(6) Ground Floor slab

item

1.00

2.96

m
m
m
m
m
m
m

5.58
2.65
1.20
0.19
0.48
7.83
3.34

79.36

TOTAL OF BILL No: 03 - Carried over to summary

3/10/2011

Page 3of 14

Riyan Pvt Ltd

IBM GODOWN

Item

Description
BILL No: 04 - MASONRY AND PLASTERING

Unit

Qty

Rate

Amount

4.1 GENERAL
(a) Rates shall include for: cleaning out cavities, forming rebated
reveals and pointing and cleaning down to reveals where
necessary; fractional size blocks, all necessary machine cutting,
cutting or forming chases or edges of
floor slabs, cutting or leaving holes and openings as recesses for
and building in pipes, conduits, sleeves and similar as required
for all trades; leaving surfaces rough or raking out joints for
plastering and flashings, bedding
frames or plates, building in joists, bearers or similar, temporary
supports to openings, templates, reinforcement in walls and for
all necessary making good.
4.2 BRICKWORK
4.2.1 150mm thick masonry solid block wall, bricks laid to form
alternate courses of headers and stretchers, laid on and incl.
mortar
4.2.1.1 Ground Floor

251.95

4.3 PLASTERING
4.3.1 16 mm thick cement plaster on internal surface as specified on
the drawing. (internal surfaces)
4.3.1.1 Ground floor

170.25

4.3.2 20 mm thick cement plaster on external surface as specified on


the drawing. (external surfaces)
4.3.2.1 Ground floor

355.77

4.3.3 20 mm thick cement screed over flat roof plywood as specified


on the drawing. (Sika Latex to be use with screed)

4.66

TOTAL OF BILL No: 04 - Carried over to summary

3/10/2011

Page 4of 14

Riyan Pvt Ltd

IBM GODOWN

Item

Description
BILL No: 05 - STRUCTURAL STEEL WORK

Unit

Qty

Rate

Amount

5.1 GENERAL
(a) Rates shall include for: all fabrication work, welding,
marking, drilling, for bolts including those securing timbers, steel
plates, bolts, nuts and any type of washer, riveted work, counter
sinking and tapping for bolts or machine screws.
(b) Rates shall include for all painting and finished as
specified.
(c)Rates shall include for fabrication and erection and temporary
supports and fixing in to position.
(d)Rate shall include for forming openings for the doors and
windows where every necessary and finishing the opening edges
smoothly using flashings as required.
5.2 STEEL COLUMNS
5.2.1 (a) I section columns bolted to the foundation using and 20mm
thk (270x450mm) grade 350 base plate with 4mm fillet weld all
around column and 4 nos of 24 mm anchor bolts as per details
given
(b) I section Columns jointed with 2 nos of 20mm thk
530x270mm plates with 8 nos of M20 G8.8 bolts and base plate
welded to I section with 8mm filet weld all around the column.
Joint to be made each C1 column)
(c) column tops fixed 20mm thk plate to required roof angle
(Plate welded 8mm fillet welding all around to column)
5.2.2
5.2.2.1
5.2.2.2
5.2.2.3

Columns C01 (171x352 mm / I section)


8.74m long columns
9.11m long columns
10.21m long columns

nos
nos
nos

10.00
10.00
5.00

First Floor
Beam B01 (171x352 Section 3871mm long)
Beam B01 (171x352 Section 5074mm long)
Beam B01 (171x352 Section 6018mm long)
Beam B01 (171x352 Section 5727mm long)
Beam B01 (171x352 Section 4968mm long)
Beam B01 (171x352 Section 5993mm long)
Beam B01 (171x352 Section 5723mm long)
Beam B01 (171x352 Section 5458mm long)

nos
nos
nos
nos
nos
nos
nos
nos

5.00
5.00
5.00
5.00
4.00
2.00
2.00
2.00

5.3.1.9 Beam B02 (165x304 Section 6370mm long)

nos

2.00

Roof level
Beam B02 (165x304 Section 4968mm long)
Beam B02 (165x304 Section 5993mm long)
Beam B02 (165x304 Section 5723mm long)
Beam B02 (165x304 Section 5458mm long)

nos
nos
nos
nos

2.00
2.00
2.00
2.00

5.3 STEEL BEAMS


5.3.1 (a) I section beams welded to base plate with 8mm weld all
around flange and 4mm weld all around web and fix to columns
with 8 M20 bolts.
(b) Rate shall include all required items as per the details given

5.3.1.1
5.3.1.2
5.3.1.3
5.3.1.4
5.3.1.5
5.3.1.6
5.3.1.7
5.3.1.8

5.3.1.10
5.3.1.11
5.3.1.12
5.3.1.13

3/10/2011

Page 5of 14

Riyan Pvt Ltd

IBM GODOWN

Item
Description
Unit
5.3.3 (a) 144mm dia 4.5mm CHS strut fixed to 120x120x10mm thk
cap plate 4mm fillet weld all around and 10mm thk cleats welded
perpendicular to cap plate.
(b) 10 mm cleat fixed to column and with 4mm filet weld all
around and strut fixed to cleat with 2 nos of M20 bolts.
First Floor
nos
5.3.4.1 4968mm long
nos
5.3.4.2 5993mm long
nos
5.3.4.3 5723mm long
nos
5.3.4.4 5458mm long
Roof level
nos
5.3.4.5 4968mm long
nos
5.3.4.6 5993mm long
nos
5.3.4.7 5723mm long
nos
5.3.4.8 5458mm long

Qty

Rate

Amount

1.00
3.00
3.00
3.00
1.00
1.00
3.00
1.00

5.4 RAFTER BEAM


(a) I section beams cut to the required angles on top and bottom
and jointed with 2 nos of 25mm thk 700x270 steel plates bolted
with 8 nos of M20 G8.8 bolts on web as per given detail and all
fillet welding shall be as mentioned
(b) I section beam jointed to each column and at ridge line at end
as per the details given and extended with a cantilever eave (as
per detail given)
( c) I section beams cut to the required angles on ridge and fixed
to column as per detail given (Columns to beam Connection)
(1) Rafter (171x352 section total 23700mm )

nos

5.00

m
no

900.00
380.00

m
no

950.00
420.00

5.5.2 Wall Bracing


(a) 75x75, 5 mm thk equal angle L angle bracing fixed to
Columns as per details given
(b) Rate shall include M20 Bolts , 6mm thk plate, L angle cleat
welded to Column and required joints on middle.
5.5.2.1 7574mm long bracing
5.5.2.2 7239mm long bracing

no
no

4.00
4.00

5.5.3 Roof Bracing


(a) 75x75, 5 mm thk equal angle L angle bracing fixed to
Columns as per details given
(b) Rate shall include M20 Bolts , 6mm thk plate and L angle
cleat welded to Column.
5.5.3.1 8306mm long bracing
5.5.3.2 7326mm long bracing

no
no

4.00
4.00

5.5.4 Flat roof support


50x200x4 mm RHS frame support by RHS bracket including
all necessary items as per details given.
5.5.4.1 50x200x4 mm RHS bracket as per details given @1500mm C/c
5.5.4.1 Horizontal bras

no
m

10.00
30.00

5.5 OTHER MEMBERS


5.5.1 RHS purlins
(a) 200x100x4mm RHS purlin fixed to first floor beams with
welding on sides and by a fly brace to each beam as per given
details.
First Floor
5.5.1.1 Purling @ 600mm C/c for floor support
5.5.1.2 fly braces fixing purlings
Roof level
5.5.1.3 Purling @ 600mm C/c for floor support
5.5.1.4 fly braces fixing purlings

TOTAL OF BILL No: 05 - Carried over to summary

3/10/2011

Page 6of 14

Riyan Pvt Ltd

IBM GODOWN

Item

Description
BILL No: 06- METALWORK

Unit

Qty

Rate

Amount

6.1 GENERAL
(a) Rates shall include for: all fabrication work, welding,
marking, drilling, for bolts including those securing timbers, steel
plates, bolts, nuts and any type of washer, riveted work, counter
sinking and tapping for bolts or machine screws.
(b) Rates shall include for all painting and finished as
specified.
(c)Rates shall include for fabrication and erection and temporary
supports and fixing in to position.
(d)Rate shall include for forming openings for the doors and
windows where every necessary and finishing the opening edges
smoothly using flashings as required.
6.2 WALL CLADING FRAME
6.2.1 Horizontal C purlings
(a) 50x100 C purling with a 5mm thk 40mmx40mm , 75mm
long L angle brackets and a 5mm thk 40mmx75mm long plate on
each joint fixed with 8 nos of M12 G8.8 Bolts on each joint (rate
for joint shall include only exceeding 6 m )
(b) Horizontal spacing to be 1000mm
6.2.1.1 Ground floor C purlings 1295 mm long
6.2.1.2 Ground floor C purlings 6270 mm long
6.2.1.3 Ground floor C purlings 6138 mm long
6.2.1.4 Ground floor C purlings 6007 mm long
6.2.1.5 Ground floor C purlings 1385 mm long
6.2.1.6 Ground floor C purlings 6248 mm long
6.2.1.7 Ground floor C purlings 6363 mm long
6.2.1.8 Ground floor C purlings 5431 mm long
6.2.1.9 Ground floor C purlings 4466 mm long
6.2.1.10 Ground floor C purlings 1134 mm long
6.2.1.11 Ground floor C purlings 5013 mm long
6.2.1.12 Ground floor C purlings 5980 mm long
6.2.1.13 Ground floor C purlings 5013 mm long
6.2.1.14 Ground floor C purlings 5944 mm long
6.2.1.15 Ground floor C purlings 5280 mm long

nos
nos
nos
nos
nos
nos
nos
nos
nos
nos
nos
nos
nos
nos
nos

4.00
4.00
3.00
3.00
2.00
4.00
4.00
4.00
4.00
4.00
4.00
4.00
4.00
4.00
4.00

6.2.1.16
6.2.1.17
6.2.1.18
6.2.1.19
6.2.1.20
6.2.1.21
6.2.1.22
6.2.1.23
6.2.1.24

nos
nos
nos
nos
nos
nos
nos
nos
nos

10.00
7.00
7.00
10.00
7.00
5.00
6.00
6.00
5.00

6.3 MAIN STAIRCASE


GI pipes, C channel and Steel Grilled stepped Staircase and
hand rail as per given detail and to manufactures specifications
item
6.3.1 Ground Floor to First Floor

1.00

First Floor C purling 1134 mm long


First Floor C purling 5013 mm long
First Floor C purling 5981 mm long
First Floor C purling 5944 mm long
First Floor C purling 5280 mm long
First Floor C purling 6248 mm long
First Floor C purling 6263 mm long
First Floor C purling 5431 mm long
First Floor C purling 4466 mm long

TOTAL OF BILL No: 06- Carried over to summary

3/10/2011

Page 7of 14

Riyan Pvt Ltd

IBM GODOWN

Item

Description
BILL No: 07 - CLADDING WORK

Unit

Qty

Rate

Amount

7.1 GENERAL
7.1.1 Rates shall include for: fair edges, dressing over angel fillets,
turning into grooves, all other labours, circular edges, nails,
screws and other fixings and laps.
7.2 WALL CLADDING
7.2.1 lysaght cladding panel to manufactures specifications and fixes
to C purling frame with self driven screws as required and Ribs
horizontally
7.2.2 Sheet rib laps should be kept for manufactures specifications and
horizontal laps to be keep minimum of 200mm laps
7.2.3 Necessary corner flashing to be fixed on corners as per
manufactures specifications
(1) Ground to roof level

409.74

m
m

556.05
556.05

8.3 CAPPING
(1) Lysaght ridge Flashing as per drawing
(2) Lysaght end Flashing as per drawing

m
m

22.39
49.58

8.4 GUTTER
(1) BHP lysaght gutter

44.78

item

1.00

5.00

TOTAL OF BILL No: 07- Carried over to summary


BILL No: 08 - ROOF WORK

8.1 GENERAL
8.1.1 Rates shall include for: fair edges, dressing over angel fillets,
turning into grooves, all other labours, circular edges, nails,
screws and other fixings and laps.
8.2 ROOF COVERING
8.2.2 BHP Lysaght Trimdek Hi-Ten or equivalent roofing sheet, over
C purlin frame including all fixings, fixed in accordance with
manufacturer's instructions.
8.2.3 50mm rockwool insulation with foil backing on one side.

8.5 DOWN PIPE


(1) 110 dia U.P.V.C. rain water pipe system
8.6 FLAT ROOF CAPPING
(1) Lysaght ridge Flashing as per drawing

TOTAL OF BILL No: 08 - Carried over to summary

3/10/2011

Page 8of 14

Riyan Pvt Ltd

IBM GODOWN

Item

Description
BILL No: 09 - WOODWORK

Unit

Qty

Rate

Amount

9.1 GENERAL
(a) Rates shall include for: all labour in framing, notching and
fitting around projections, pipes, light fittings, hatches, grilles
and similar and complete with cleats, packers, wedges and
similar and all nails and screws.
9.2 TIMBER VALANCE BOARD
25X250 Timber plank and Flat ZnAl sheet (to cover the balance
of truss-270mm high) fixed to the roof truss

44.78

9.3 PLYWOOD FLOOR


25mm thk marine plywood decking

518.23

9.4 FLAT ROOF


25mm thk marine plywood decking

4.66

TOTAL OF BILL No: 09 - Carried over to summary


BILL N0: 10- DOORS AND WINDOWS

10.1 GENERAL
(a) Rates shall include for locks, latches, closers, push plates,
pull handles, bolts, kick plates, hinges and all door & window
hardware.
(b) Rates shall include for door frames, mullions, transoms,
trims, glazing, tinting, timber panels, boarding, framing, lining,
fastenings and all fixings.
(c) Sizes are given overall outside dimensions of actual doors
and windows.
(d) Thickness and sizes of glass panels are shown on the
Drawings and doors and windows schedule
(e) Rates shall include for all painting as specified
(f) Rates shall include all items specified in the door schedule
and specification
(g.) Frames and sashes to be 25-60 micron White powder
coated Aluminium other wise specified.

10.2
10.2.1
(1)
(2)
(3)
(4)
(5)
(6)
(7)

DOOR AND WINDOW UNITS


GROUND FLOOR
GD (5730x2600) Steel frame Roller shutter / Mechanical sys.
GD01 (4705x2600) Steel frame Roller shutter / Mechanical sys.
D1 (1700x2150) Al framed and louvers swing door
D2 (750x2150) PVC Door
W1 (5730x1000) Alluminium window with Fixed louvers
W1a (4705x1000) Alluminium window with Fixed louvers
Opening (3600x1650) Transparent sheet

nos
nos
nos
nos
nos
nos
nos

1.00
1.00
1.00
2.00
2.00
1.00
1.00

10.2.2
(1)
(2)
(3)
(4)

FIRST FLOOR
D1 (1700x2150) Al framed and louvers swing door
W02 (5730x1775) Alluminium Door with Glass opening
W02a (4946x1775) Alluminium Door with Glass opening
W02b (4705x1775) Alluminium Door with Glass opening

nos
nos
nos
nos

1.00
1.00
1.00
1.00

10.3 OTHERS
Sun portal day light system (fixed as per manufacture's
specifications)

nos

8.00

TOTAL OF BILL No: 10 - Carried over to summary

3/10/2011

Page 9of 14

Riyan Pvt Ltd

IBM GODOWN

Item

Description
BILL No: 11 - PAINTING

Unit

Qty

Rate

Amount

11.1 GENERAL
(a) Rates shall include for: the provision, erection and removal
of scaffolding, preparation, wall putty application, rubbing down
between coats and similar work, the protection and/or masking
floors, fittings and similar work, removing and
replacing door and window furniture
(b) All painting work shall be carried in accordance with the
Specifications
11.2 WALL PAINTING
11.2.1 Textured paint finish/matte emulsion paint finish as specified in
specification. (external surfaces)
(1) Ground Floor

170.25

11.2.2 Emulsion paint finish including putty application and ground


smoothing as specified in specification. (internal surfaces)
(1) Ground floor

355.77

2.30

8.93

TOTAL OF BILL No: 11 - Carried over to summary


BILL No: 12 - FINISHES
12.1 GENERAL

(a) Rates shall include for: fixing, bedding, grouting, and


pointing materials; making good around pipes, sanitary
fixtures, and similar; cleaning down and polishing.
12.3 TOILET FLOOR TILING
12.3.1 300x300mm non-slip ceramic floor tiles, (waterproofed

with either additivites with or applicants over slab with


SIKA products or equivalent) ,@ toilets
(1) Ground floor
12.4 TOILET WALL TILING
12.4.1 200mm x 300mm ceramic wall tiles up to 1.2m height

(toilet)
(1) Ground floor

TOTAL OF BILL No: 12 - Carried over to summary

3/10/2011

Page 10of 14

Riyan Pvt Ltd

IBM GODOWN

Item

Description
Unit
BILL No: 13 - HYDRAULICS AND DRAINAGE
13.1 HYDRAULICS
13.1.1 General
(a) Rates shall include for: sockets, running joints, connectors,
elbows, junctions, valves, reducers, expansion joints; backnuts
and similar; incidental fittings, clips, saddles, brackets, straps,
hangers, screws, nails and
fixing complete, including cutting and forming holes; excavating,
laying pipes and backfilling trenches
(b) All pipework and fittings shall be UPVC

13.1.4 Fresh water supply pipe


(2) 20mm dia fresh water PVC pipe
(3) 16mm dia fresh water PVC pipe

Qty

item
item

1.00
1.00

no
no
no
no
no
no

2.00
2.00
2.00
2.00
1.00
3.00

13.2.2 Drainage pipe work


(1) 110mm dia soil pipe
(3) 82mm dia waste pipe

item
item

1.00
1.00

13.2.5 manholes
600mm dia,600mm deep RCC Inspection chamber with RCC
cover slab sealed type

nos

1.00

13.1.5
(1)
(2)
(3)
(4)
(5)
(6)

Sanitary fixture and fittings


WC
Soap holder
Muslim shower
Floor trap
Gate valve
Floor drain

Rate

Amount

13.2 DRAINAGE
13.2.1 General
(a) Rates shall include for: excavation, maintaining faces of drain
pipe trenches and pits, backfilling, disposal of surplus spoil;
bends, junctions, reducers, expansion joints and all joints and
other incidental materials.
(b) All pipework shall be uPVC

TOTAL OF BILL No: 13 Carried over to summary

3/10/2011

Page 11of 14

Riyan Pvt Ltd

IBM GODOWN

Item

Description
Unit
BILL NO: 14 - ELECTRICAL INSTALLATIONS
14.1 GENERAL
(a) Design, provide and install electrical network for the entire
building complete in accordance to standards set by the local
governing body STELCO
(b) The following items and description and the drawings HULS
-01 to HULS-05 are given as a guidance as to the nature of the
information required to be returned by the
contractor. Should they not be appropriate the contractor should
provide a similar BoQ using the Add/Omit sheets provided at the
back of this BoQ
(c) The cost shall include for: screws, nails, bolts, nuts, standard
cable fixing or supporting clips, brackets, straps, rivets, plugs and
all incidental accessories
(d) The cost shall also include for trenching including:
excavation, maintaining faces of excavations, backfilling,
compaction, appropriate cable covers, warning tape and disposal
of surplus spoil
(e) Rates for electrical isolators, conduits, fittings, equipment
and similar items shall include for: all fixings to various building
surfaces
(f) A light fixture is measured as one point; switch end of wire is
not included in the quantity.
(g) A point wiring for power points is measured (regardless of 1
gang, 2 gang etc) as one point for each socket outlet; other end of
wire is not included in the quantity.
(h) Contractor shall provide all cabling, wiring, conduits, etc.
within the site boundaries. Cabling, wiring, conduits etc. outside
the site boundaries are not included under this Contract.

Qty

14.2 MAINS CONNECTION


(1) Allow for connection to electrical mains
(2) Allow for connection to Generator

no
no

1.00
1.00

14.3 ELECTRICAL BOARDS


Complete installation, including for all cabling, wiring,
connections, earthing, painting, testing and similar of:
(1) Light Distribution board
(2) power Distribution board
(3) Main electrical panel with supply change over

no
no
no

2.00
2.00
1.00

points
points

39.00
14.00

no
no
no
no

2.00
28.00
3.00
6.00

14.7 SWITCHES
(1) Light switch

no

34.00

14.8 SOCKETS
(1) 13 A SSO
(2) 13 A twin SSO

no
no

7.00
7.00

14.4 ELECTRICAL WIRING


Electrical wiring with copper conductor cable in conduits in
walls and in casing on soffits of slab as specified to:
(1) Wiring to light & fan fixtures
(2) Wiring to power points
14.5
(3)
(4)
(5)
(6)

LIGHTING
Ceiling light
22" Aluminium Low bay light (40W)
4 ft Fluorescent industrial light
Emergency Lights

Rate

Amount

TOTAL OF BILL No: 14 Carried over to summary

3/10/2011

Page 12of 14

Riyan Pvt Ltd

IBM GODOWN

Item

Description
BILL NO: 15- LIFT & HOISTS WORKS

Unit

Qty

Rate

Amount

15.1 LIFTS
15.1.1 GENERAL
(a) Rates shall include for: screws, nails, bolts, nuts, standard
cable fixing or supporting clips, brackets, straps, rivets, plugs and
all incidental accessories
(b) Rates for work in trench shall include for: excavation,
maintaining faces of excavations, backfilling, compaction,
appropriate cable covers, warning tape and disposal of surplus
spoil
(c) Rates for cable conduits, fittings, equipment and similar
items shall include for: all fixings to various building surfaces
(d) Rates shall include for all necessary electrical wiring and
accessories required for completion of the lift installation
(e) MWSC will supply the Scissor type Elevator.
(e) Rate shall include shifting the Elevator from Hulhumale and
complete installation.
15.1.2 Scissor Type Freight Elevator from autoquip or similar to
specifications (rate shall include all supporting frame works and
any additional items required)

nos

1.00

TOTAL OF BILL No: 15 Carried over to summary


BILL NO: 16- ADDITIONS AND OMMISIONS

3/10/2011

Page 13of 14

Riyan Pvt Ltd

IBM GODOWN

Item
16.1
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
(12)
(13)
(14)
(16)

Description

Unit

Qty

Rate

Amount

ADDITIONS
Bill 01- Preliminaries
Bill 02- Ground works
Bill 03- Concrete works
Bill 04- Masonry works
Bill 05- Structural steel work
Bill 06- Metal works
Bill 07- Cladding works
Bill 08- Roofing
Bill 09- Wood work
Bill 10- Door window
Bill 11- Painting
Bill 12- Finishes
Bill 13- Hydraulics and Drainages
Bill 14- Electrical installation
Bill 15- Lift & Hoists work
TOTAL

16.2
(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)
(9)
(10)
(11)
(12)
(13)
(14)
(16)

OMISSIONS
Bill 01- Preliminaries
Bill 02- Ground works
Bill 03- Concrete works
Bill 04- Masonry works
Bill 05- Structural steel work
Bill 06- Metal works
Bill 07- Cladding works
Bill 08- Roofing
Bill 09- Wood work
Bill 10- Door window
Bill 11- Painting
Bill 12- Finishes
Bill 13- Hydraulics and Drainages
Bill 14- Electrical installation
Bill 15- Lift & Hoists work
TOTAL

TOTAL OF BILL No: 16 Carried over to summary

3/10/2011

Page 14of 14

Riyan Pvt Ltd

S-ar putea să vă placă și