Sunteți pe pagina 1din 3

EQ751 - OPERAES UNITRIAS II

1. (Example 3.1, Serth) A double-pipe heat exchanger will be used to cool a hot stream
from 350F to 250F by heating a cold stream from 80F to 120F. The hot stream will
flow in the inner pipe, which is 2-in. schedule 40 carbon steel with a thermal
conductivity of 26 Btu/hft2F. Fouling factors of 0.001 hft2F/Btu should be provided
for each stream. The heat-transfer coefficients are estimated to be hi = 200 and ho = 350
Btu/hft2F, and the heat load is 3.5x106 Btu/h.
(a) For counter-current operation, what surface area is required?
(b) For co-current operation, what surface area is required?

2. (Example 3.2, Serth) A fluid is to be heated from 100F to 160F by heat exchange
with a hot fluid that will be cooled from 230F to 150F. The heat-transfer rate will be
540,000 Btu/h and the hot fluid will flow in the tubes. Will a 1-2 exchanger (i.e., an
exchanger with one shell pass and a multiple of two tube passes) be suitable for this
service? Find the mean temperature difference in the exchanger.

3. (Example 3.3, Serth) 10,000 lb/h of benzene is to be heated from 60F to 120F by
heat exchange with an aniline stream that will be cooled from 150F to 100F. A
number of 16 ft hairpins consisting of 2 in. by 1.25 in. schedule 40 stainless steel pipe
(type 316, k = 9.4 Btu/hftF) are available and will be used for this service. Assuming
that the benzene flows in the inner pipe, how many hairpins will be required?

4. (Example 3.4, Serth) In a petroleum refinery, it is required to cool 30,000 lb/h of


kerosene from 400F to 250F by heat exchange with 75,000 lb/h of gas oil, which is at
110F. A shell-and-tube exchanger will be used, and the following data are available:

For the purpose of making a preliminary cost estimate, determine the required heattransfer area.

5. (Exemplo, Roger) 5,5 kg/s de querosene deixam o fundo de uma coluna de destilao
a 200C e so resfriados at 91C por 18,75 kg/s de leo bruto proveniente de um
reservatrio a 37,5 C e aquecido at 76C.
Uma queda de presso mxima de 70 kPa admissvel para ambos os fluidos, e um
fator de incrustao combinado de 0,0005 m2C/W desejado.
Dispe-se para este servio um trocador com dimetro interno de casco de 0,540 m
(21,25 polegadas), com 158 tubos de dimetro externo de 0,0254 m e dimetro interno
de 0,2057 m (0,81"), passo quadrado de 0,03175 m (1,25") e comprimento de 4,877 m
(16 ps). O feixe configurado para 4 passagens. A distncia entre as chicanas de
0,127 m (5").
Verifique se este trocador conveniente, e calcule o fator de incrustao disponvel (ou
o excesso da rea).

6. (Exemplo 5.1, Aline) Um trocador de placas paralelas requerido para aquecer 5 kg/s
de Dowtherm A de 15 a 85C usando gua, que resfriada de 95 a 60C. Assuma que
as placas so de 1 por 0,25 m com espaamento entre elas de 5 mm e elas tm as
caractersticas descritas pela figura 5.6. Quantas placas so requeridas para um trocador
de um passo em contracorrente? Se a queda de presso permitida para bombear a gua
quente atravs do trocador 104 N/m2, o trocador apropriado?
Propriedades dos fluidos:
Cp (Dowtherm A) a 50C=1660 J/kgK
Cp (gua) a 77C=4195 J/kgK
(Dowtherm A) a 50C =2,1510-3 (Ns)/m2
(gua) a 77C =3,6510-4 (Ns)/m2
k (Dowtherm A) a 50C=0,137 W/(mK)
k (gua) a 77C =0,668 W/(mK)
(Dowtherm A) a 50C =1036 kg/m3
(gua) a 77C =973,7 kg/m3

7. (Exemplo 6.1, Aline) Um evaporador alimentado com 10000 lb/h de uma soluo
contendo 1% de soluto em peso. A alimentao est a 100F. Esta soluo
concentrada at 1,5% de soluto em peso com o evaporador operando a 1 atm. O vapor
usado est a 5 psig e 227F. Considere que a soluo sendo evaporada muito diluda e
que suas propriedades podem ser consideradas iguais s da gua pura.

a) Qual a massa de vapor gerada?


b) Qual a massa de vapor requerido?
c) Qual a superfcie de troca requerida?
Dado: U=250 Btu/hft2F
of the exchanger.

8. (Exemplo 6.2, Aline) Um evaporador de efeito simples usado para concentrar


20000 lb/h de uma soluo com 20% em peso de NaOH at 50% em peso. A presso
(gauge) do vapor alimentado 20 psig e a presso absoluta de vapor no casco 1,93
psia. O coeficiente global de transferncia de calor U=250 Btu/hft2F. A temperatura
da alimentao 100F. Calcule a quantidade de calor requerida, a economia e a
superfcie de troca requerida. So dados:

9. (Exemplo, Roger) Projetar um refervedor para gerar 2,5 kg de vapor de ciclohexano,


para uso em uma coluna de destilao. A presso no funda da coluna de 1,10 bar, que
corresponde a uma temperatura de ebulio de 83,3C. O refervedor utiliza vapor d'gua
saturado a 108,5C (o que corresponde a uma presso de 1,37 bar). A resistncia devido
a incrustao do ciclohexano estimada como 0,000175 m2C/W, e o coeficiente de
transferncia de calor do vapor d'gua com 5700 W/m2C.