Sunteți pe pagina 1din 3

TD-5100

Turner Designs Hydrocarbon Instruments new

Scrubber Wash Water Monitor

keeps you smooth sailing in ECA waters.


PAH
Turbidity
Temperature
pH

Are you ready for the January 2015 ECA Compliance?

The TD-5100
helps protect
the environment from unwanted
high levels of contamination in
exhaust gas scrubber wash
water discharge.

TURNER

DESIGNS

Hydrocarbon Instruments

TD-5100

Scrubber Wash Water Monitor


Marine Exhaust Gas Scrubbing systems for Heavy Fuel Oil burning ships are
becoming main stream with various configurations including open loop, closed loop
and hybrid systems. Oxides of Sulfur and Nitrogen along with particulates and
unburned hydrocarbons are removed into the very high volumes of wash water
sprayed into the exhaust scrubber system. The wash water can be a combination of
seawater with a natural buffer capacity and/or fresh water with buffer added to
neutralize the acids formed when sulfur contacts the water. The contaminated wash
water is then discharged directly to the sea or contained and treated before
discharge depending on the system and the specific rules that apply to that situation.
With the exhaust contaminants then contained in the water phase, the environment
must be protected from abnormally high discharges.

Monitors:

By rule as dictated by MARPOL Annex VI, MEPC. 184(59), Poly Aromatic


Hydrocarbons (PAH), Turbidity, pH, and Temperature must be monitored at all times

PAH
Turbidity
Temperature
pH

while discharging scrubber wash water to the sea. However, standard off the shelf
sensors have proven less than adequate for rugged marine service in contact with the
wash water and their ability to pass marine certification has come to question. With
our history of marinized, rugged, built for purpose fluorescence analyzers and
monitors for bilge water, drilling rig deck drains, steam condensate, and overboard
oilfield produced water, we designed and tested a system specifically to answer the
MARPOL requirements for PAH, Turbidity, Temperature with external pH probe.
The Wash Water Discharge Monitor TD-5100

is ready for January 1, 2015

when the low sulfur fuel rule goes into effect. The pain of not knowing if your
monitoring system is really working is now off the table. Our new system provides

TURNER

DESIGNS

Hydrocarbon Instruments

PAH, Turbidity and Temperature with pH supplied as a separate, stand alone probe /
transmitter. It covers the entire range of concentrations, is self-cleaning, and operators

2023 N. Gateway Blvd., Suite 101

can validate operation for Port State Control inspectors or management onboard at

Fresno, California 93727 USA


TEL : 559 253 1414 / FAX: 559 253 1090

any time. The TD-5100

is rugged, marinized and uses the same user dictated

design philosophy of every Turner Designs Hydrocarbon Instruments monitor.

sales@ oilinwatermonitors.com / oilinwatermonitors.com

2015 TURNER DESIGNS HYDROCARBON INSTRUMENTS, INC.

Worldwide Sales and Service

105648 Rev. B

TD-5100

Scrubber Wash Water Monitor

S P E C I F I C A T I O N S
Performance

All measurements are made in accordance with Annex 9, MEPC. 184(59)

Measurements and Ranges


Operational Principle (PAH and Turbidity)

UV Fluorescence + UV absorption + Near IR light scatter

PAH

3 - 5000 ug/L as PAHphe

Turbidity

0 - 200 NTU

Sample Water Temp

0 C - 50 C (32 F - 122 F) +/-1% accuracy

pH

2.5 - 11 (external probe)

Calibration

With safe, non-toxic water soluble PAHphe surrogates traceable to factory standards

Calibration Frequency

Annually

Drift

<10% 12 months referenced against calibration standards

PAH Stability vs Increased Turbidity

Stable within +/- 10% over normal turbidity range

Response Time

HOME screen user settable update: 3, 10, 20, or 30 seconds

Onboard Validation

With safe, non-toxic water soluble PAHphe surrogates traceable to factory standards

Security

Multi level password protected user interface

Electronics Cabinet

316 Stainless Steel IP 66

Envelope Dimensions

Height 648 mm x Width 671 mm x Depth 269 mm ( 25 1/2" x 26 3/8" x 10 1/2")

Weight

[34 kg] 75 lbs

Power Requirements

115 VAC or 230 VAC Specified at time of order

Wiring (customer supplied)

Power and Alarms 14 AWG [2.08 mm2], Analog Signal 18 AWG [.82 mm2]

Inlet Plumbing Requirements

3/8" MNPT [9.5 mm] or EN 10226 Rs 3/8"

Outlet Plumbing Requirements

3/8" MNPT [9.5 mm] or EN 10226Rs 3/8"

Process / Sample Conditions


Inlet Sample Flowrate

.5 L/m - 2.0 L/m (.13 g/m - .5 g/m)

Inlet/Outlet Sample Pressure

34.5 - 689.5 kpag (5 - 100 psig)

Sample Temperature

0 - 50 C (32 F - 122 F)

Sample pH

pH 2.5 - 11

Turbidity Range

10 - 200 NTU

Sample Water

Sea or fresh water, open or closed loop washwater

Ambient Conditions
Ambient Temperature

0 - 45 C (32 F - 113 F)

Vibration, Shock, EMI

In accordance with MED, USCG and DNV GL Requirements

General Service Conditions


Alarms

Communication failure, Lamp failure, Temperature: enclosure, Temperature: process,


Real-time clock, System memory, Concentration alarms, Cleaning alarms

TURNER

DESIGNS

Hydrocarbon Instruments

Alarm Outputs

Relays 1 - 2, Configurable

Communication

4 - 20 mA standard, Ethernet and Modbus available on request

2023 N. Gateway Blvd., Suite 101

Diagnostics

Events, relay status, alarm status, temperature (enclosure, process), optical measurements,
firmware, datalog files

Fresno, California 93727 USA


TEL : 559 253 1414

Cell Condition Monitor

Determines when sample cell needs cleaning during clean water injection

FAX: 559 253 1090

Sample Pump

Only if necessary for sample pressure <34.5 kpag (< 5 psig)

sales@ oilinwatermonitors.com

Cleaning System

Ultrasonic: on timer or as needed

Data Logger

E09 Data Logger with data transfer via USB Flash Drive

ISO Certified

9001: 2008 Quality System

2015 TURNER DESIGNS HYDROCARBON INSTRUMENTS, INC.

105648 Rev. B

oilinwatermonitors.com