Message Overview:
stall fail
(Caution)
NO GO /or MMEL RELIEF
NO GO
NO GO
27-35-00
Schematic Diagram:
27-35-00
Wiring Diagram:
MMEL Dispatch:
For reference from the QRH GO/NO GO Guide.
Please note: A "GO" condition still requires MMEL consultation.
Fault Logic:
The Stall Protection Computer detects single, non-single or internal failures and provides a discrete
(ground) to the DCUs, to post the STALL FAIL amber CAS message.
Possible Causes:
https://customer.aero.bombardier.com/smartfixplus/cl605/ch605/ch605/troubleshooting/ata/... 1/3/2016
STALL FAIL
Page 2 of 7
Troubleshooting Tips:
Advisory Wire/Service Bulletin: AW600-27-2224 and SB605-27-001
Forum Articles/Infoservice/Newsletter: None
NOTE: When the aircraft is weight-on-wheels (WOW), the stall protection computer will not operate
but the SPS self-test will.
The latest Stall Protection Computers (SPCs) were recently upgraded to detect dormant internal
failures, by introducing new monitor circuits. Those added monitoring capabilities are:
https://customer.aero.bombardier.com/smartfixplus/cl605/ch605/ch605/troubleshooting/ata/... 1/3/2016
STALL FAIL
Page 3 of 7
During a single channel test (left or right) is activated, the SPC inhibit the associated channel altitude
input and the Alt Comp Fail and Stall Fail are annunciated. During a dual channel test the only
the Stall Fail is annunciated.
Quick Links:
Leveling the Aircraft on jacks
AMM 08-20-01-589801
AMM 27-35-04-820801
AMM 27-35-04-720801
AMM 27-35-25-820801
Functional Test of the Flap and Sideslip Compensation Monitor of the Stall Protection
System
AMM 27-35-01-720803
AMM 27-35-01-000801
AMM 27-35-01-400801
AMM 27-35-07-000801
AMM 27-35-07-400801
AMM 27-35-04-000801
AMM 27-35-04-400801
https://customer.aero.bombardier.com/smartfixplus/cl605/ch605/ch605/troubleshooting/ata/... 1/3/2016
STALL FAIL
Page 4 of 7
AMM 27-35-25-000801
AMM 27-35-25-400801
AMM 27-55-01-000801
AMM 27-55-01-400801
AMM 27-35-19-000801
AMM 27-35-19-400801
Wiring Repair
SPM 20-12-10-02
Troubleshooting Recommendations:
If STALL FAIL is shown on the Ground and in Air proceed as follow base on the possible
cause:
https://customer.aero.bombardier.com/smartfixplus/cl605/ch605/ch605/troubleshooting/ata/... 1/3/2016
STALL FAIL
Page 5 of 7
3. Loss of ODD parity at Discrete Calibration Input Pins of the Converter. (AC5701-5827) Post
SB605-27-001 and (AC5728-5990).
1. Channel 1 LH Converter P13CG- 3/4/5/20/21/32 To GND N595.
2. Channel 2 RH Converter P12CG- 3/4/5/20/21/32 To GND N651.
NOTE: Must have ODD number of grounds connected!
4. Failure of the stick shaker or stick pusher circuits in the SPS computer. (ALL).
1. Check Both Pusher Switches and make sure that both switches are in the ON position.
2. Verify that both shaker connectors P5CG & P6CG are hooked up properly.
3. Sticky Accelerometer Switch MT5CG.
1. With the Aircraft leveled, check presence of a Ground at JB11-PCB10 TP-A29
(WM 27-35-00 sheet 13/17).
2. Fail Relay K1CG in JB11-PCB10.
5. Failure of one or both of the angle-of-attack transducers, or a difference, exceeding 3.5 degrees,
in the compensated AOA signals. (AC5701-5827) Pre SB605-27-001.
1. 36 ohms per deg X 3.5 deg = 126 Ohms resistance difference between the L/H and the
R/H at the same position (i.e. 0 degree). Measure resistance at P1CG (P2CG)-c(+) and b
(-), if higher than 126 Ohms:
1. Perform AOA alignment check per AMM Task 27-35-04-820-801.
2. Perform AOA Transducer Linearity check per AMM Task 27-35-04-720-801.
2. (AC5701-5827) Post SB605-27-001 and (AC5728-5990)
Since on those Aircraft the Vanes are digital, with Breakout Box GSE Tool PN:
CCSC2739-01 installed, measure voltage at connector P1CG (P2CG):
PIN
VOLTAGE
15V
5V
15V
-10
14V
https://customer.aero.bombardier.com/smartfixplus/cl605/ch605/ch605/troubleshooting/ata/... 1/3/2016
STALL FAIL
Page 6 of 7
13V
12V
11V
10
10V
15
9V
20
8V
25
7V
30
6V
35
5V
6. A difference, exceeding 0.03 G slide slip, in the signals from the lateral accelerometers. With
Breakout Box GSE Tool PN: CCSC2739-01 installed, do as follows:
1. Voltage input from the L/H (P1CG M & N) and R/H (P2CG M & N) accelerometer to
the SPC is 0+/- 10mv, if not adjust accelerometer per task 27-35-25-820-801 (when A/C
level) or 27-35-25-820-802 (when a/c not level).
2. Hook up a multimeter between both accelerometers P1CG-M & P2CG-M and measure
the differential voltage, the STALL FAIL will be displayed if voltage is higher then +/450mV corresponding to a 0.03g difference between accelerometers.
3. With the multimeter verify that the voltages of L/H and R/H accelerometer is coming
back to approximately 0 Vdc =/- 10mV after moving the a/c (shake).
4. Ensure that the voltages do not start to drift after sometime when the power is left ON for
approximately +/- 2hours.
7. Flap Switches on L/H and R/H should be identical for each Flap Setting, otherwise a Stall Fail
will be triggered by SPC, Troubleshoot according to this logic (Breakout Box GSE Tool PN:
CCSC2739-01 can be use):
Flap Setting
20
Flap SW No P1CG/P2CG
at SPC
Pin
3
2
1
d
T
X
5
25
35
Ground
Ground
Ground
3
2
d
T
5
25
Open
Ground
35
Ground
https://customer.aero.bombardier.com/smartfixplus/cl605/ch605/ch605/troubleshooting/ata/... 1/3/2016
STALL FAIL
Flap Setting
30
40
Page 7 of 7
Flap SW No P1CG/P2CG
at SPC
Pin
3
2
d
T
5
25
Open
Open
35
Ground
Open
2
1
T
X
25
35
Open
Open
8. As an alternative and/or additional procedure of previous Step 6) and 7) you can simulate
Lateral Acceleration and Flap Setting at the SPC with GSE tool 27-35-05 and AMM Task
Procedure 27-35-01-720-803 Functional Test of the Flap and Side slip Compensation Monitor
of the Stall Protection System. Please refer accordingly.
9. Verification of the Weight-On-Wheel signal from the PSEU (Breakout Box GSE Tool PN:
CCSC2739-01 can be use), Follow this logic:
PSEU Output
WOW 1 STALL
N/A
WonW
Ground
N/A
WoffW
Open
N/A
WonW
Ground
N/A
WoffW
Open
OK
Open
Failed
Ground
Warning
WOW 1 STALL
Warning
WOW 2 STALL
Warning
WOW 2 STALL
Warning
10. Experience in the field has taught us that caution should be taken not to over torque the cage
during the installation of the SPS Test Indicator (M1CG & M2CG) as it may cause a binding in
SPS indicator needle.
https://customer.aero.bombardier.com/smartfixplus/cl605/ch605/ch605/troubleshooting/ata/... 1/3/2016