Documente Academic
Documente Profesional
Documente Cultură
IF cables connect
RAU with MMU
Types of protection
Protection divided in three types
1- Protection (2+2)
- Used frequency as Vertical & Horizontal to duplicate the traffic .
- Used 4 MMU cards .
- Used 4 RAU outdoor .
- Used XPIC cable to connect between Vertical & Horizontal MMU .
- Used waveguide cable to connect between Vertical & Horizontal
RAU .
- Used for huge traffic .
Types of protection
2-Protection (1+1)
-used all frequency to transfer the traffic .
-used 2 MMU cards .
-used 2 RAU outdoor .
-less interference than (2+2) protection .
Types of protection
3-Protection (1+0)
-used all frequency to transfer the traffic .
-used 1 MMU card .
-used 1 RAU outdoor .
-less secure than (1+1) protection
HOW TO ACESS TO
E/// LINK (20P)
PC IP (LINK IP+1)
SUBNET MASK AS Shown
LINK IP As Shown
Username=control_user
Password=ericsson
HOW TO ACESS TO
E/// LINK (20P)
HOW TO ACESS TO
E/// LINK (20P)
IP=10.0.0.1
User= control_user
Password= ericsson
Press start
From TN configure
load configuration
Press Apply
File saved in
c:\tn_ftp_home\tn_backup
_configuration
HOW to Restart TN
HOW to Restart TN
Open MMU2 H
open RAU IF
from switch
Choose performance
From TN View
Notification History
Press (CTRL+A)
then press (CTRL+C)
to copy
Gets TX & RX
value
Press on loops
Press on RF icon to
make loop on RAU to
check both
(RAU+IF+MMU)
Press on BR button
Kinds of alarms at TN
Intermediate alarm
Warning alarm
Critical alarm
Minor alarm
Major alarm