Water Cooling Pump


WL 5000 SE
Operating Instructions

X-ray

Operating Instructions WL 5000 SE

1st Edition
Documentation ID No.

2540570/EB.0109

Published by GE Sensing & Inspection Technologies GmbH


Reference: hi, jo, dr

Date: 01/23/2009

File: WL5000SE_e.indd

Printed in Germany 2009


GE Sensing & Inspection Technologies GmbH reserves the right to technical modifications without
prior notice. No part of this publication may be reproduced, stored in a retrieval system, or transmitted,
in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without
the prior written consent of GE Sensing & Inspection Technologies GmbH.

Copyright by GE Sensing & Inspection Technologies GmbH

Bogenstrasse 41 22926 Ahrensburg

01/23/2009
1. Edition, ID No.: 2540570/EB.0109

Operating Instructions WL 5000 SE


Table of Contents
1

Safety Measures...................................................................................................................................................... 4

Description............................................................................................................................................................... 5

Putting into Operation........................................................................................................................................... 6

Maintenance............................................................................................................................................................ 7
4.1

Heat Exchanger........................................................................................................................................................................7

4.2

Pump..............................................................................................................................................................................................8

Placing out of Operation........................................................................................................................................ 8

Flow Chart................................................................................................................................................................ 9

Technical Data....................................................................................................................................................... 10

Spare Parts............................................................................................................................................................. 11

Circuit Diagram..................................................................................................................................................... 12

Copyright by GE Sensing & Inspection Technologies GmbH

01/23/2009
1. Edition, ID No.: 2540570/EB.0109

Bogenstrasse 41 22926 Ahrensburg

Operating Instructions WL 5000 SE


1

Safety Measures

Carefully read the Operating Instructions prior to commissioning.

The mains connection is 230 V 50/60 Hz.

The coolant is either water or a water-glycol mix according to the Description.

Use only completely intact cooling hoses.

Operate the equipment only if the tank is filled to the proper level and the ball valve
on the pumps suction side is open. Otherwise the pump might suffer damage.

The water level must always be above the cooling fins. Otherwise the cooling output
is impaired.

Clean the pump filter according to the Maintenance Instructions. Otherwise the pump
may suffer damage.

Make sure the cooling hoses are pressure-proof and resistant to the coolant used.

Do not commission the equipment with hoses that are damaged or show leaks.

Perform maintenance routines only if the water cooling pump is isolated from the
power supply, i.e. first switch off the pump and then disconnect the electric connecting
cables, e.g. by unplugging the connectors.

Never open the water cooling pump during operation.

Copyright by GE Sensing & Inspection Technologies GmbH

Bogenstrasse 41 22926 Ahrensburg

01/23/2009
1. Edition, ID No.: 2540570/EB.0109

Operating Instructions WL 5000 SE


2

Description
The WL 5000 SE water cooling pump serves the cooling of X-ray tubes in a closed water
circuit.
The coolant can be either water or a water-glycol mixture.
Only GlycoShell must be used:
Article no. 9434660 = 1 liter

Do not mix GlycoShell with other coolant additives since this will cause coolant flocculation
and total failure of the circulation pump (if necessary empty the water cooling circuit and
refill it with a new mixture of GlycoShell and water).
Therefore, watch the cooling water color:

are:
Correct
Incorrect are all deviating colors:

Clear or dark blue-green


Red, brown, black e.g.

Down to a temperature of 25C we recommend a ratio of


two parts GlycoShell and three parts water.

(Filling quantity about 5.0 l + 0.075 l/m hose = 6.5 l for a 20 m hose length [10 m inlet + 10 m outlet])

The water circulates between the cooling unit and the X-ray tube. The water is recooled via
an air-cooled heat exchanger. A bypass valve limits the maximum pressure of the pump.
The maximum cooling output depends on the difference between the ambient temperature
and the water outlet temperature.
The power amounts to 5000 W with the temperature difference of 13,2 K between water
outlet and ambient temperature.
The cooling hoses with a 9 mm inside diameter are connected to the water cooling pump
via hose sleeves.
Water inlet and water outlet are marked by symbols:

Inlet: O ;

Copyright by GE Sensing & Inspection Technologies GmbH

01/23/2009
1. Edition, ID No.: 2540570/EB.0109

Outlet: O .

Bogenstrasse 41 22926 Ahrensburg

Operating Instructions WL 5000 SE


3

Putting into Operation


-

Set up the equipment such that air inlet and air outlet are not blocked. If blocked, the
cooling output is impaired.

Lufteintritt
Air Inlet

Luftaustritt
Air Outlet

Minimum 0,80 m

Minimum 0,80 m

Use the cable to establish the electric connection.

Connect the water hoses.

Open the filler stub. Fill the tank with drinking


water, about 5.0 l + 0.075 l/m hose. The water level
must be about 3 cm above the cooling fins.

The water level must always be above he cooling


fins. Otherwise the cooling output is impaired.

Filler stub

- Start the water circuit to vent trapped air.


- Check the water level. Add some more water if needed.
- Close the filler stub.
- The water cooling pump is ready for operation.

Copyright by GE Sensing & Inspection Technologies GmbH

Bogenstrasse 41 22926 Ahrensburg

01/23/2009
1. Edition, ID No.: 2540570/EB.0109

Operating Instructions WL 5000 SE


4

Maintenance
Regularly check the water level in the tank. Add drinking water if needed.
Clean the heat exchanger and the pump filter once a month*).
*)

4.1

Factors such as the formation of algae, heavy soiling or an unusually long operating cycle necessitate
shorter maintenance intervals.

Heat Exchanger
As a dirty heat exchanger will lower the cooling output, regular checks are the safest
method to find out whether the cooling fins need cleaning or not. If they do, proceed in
the following way:
-

Isolate the water cooling pump from the power supply.


See Safety Measures.

Dismount the siding and the cover.

Blow clean the cooling fins by applying compressed air. Be careful not to damage the
cooler.

Remount the siding and the cover.

Copyright by GE Sensing & Inspection Technologies GmbH

01/23/2009
1. Edition, ID No.: 2540570/EB.0109

Bogenstrasse 41 22926 Ahrensburg

Operating Instructions WL 5000 SE


4.2

Pump
If the equipment is operated with a dirty filter, pump and motor may suffer damage.
Clean the filter in the following way:
-

Isolate the water cooling pump from the power supply. See Safety Measures.

Dismount the siding.

Close the ball valve on the pump side.

Unscrew the filter cover (see Figure)


(24 mm key width).

Some water will escape. Use a suitable


container to catch it.
-

Remove the filter. Clean it or replace it


by a new filter.

Insert the filter. Screw the filter cover


on tight.

Open the ball valve. If the filter cover is untight, tighten it once more.

Do not put the equipment into operation when the ball valve is closed. Otherwise the
pump may suffer damage.

Remount the siding.

Establish the electric connection. Let the water cooling pump run for about 10 minutes
to vent trapped air and to simultaneously check the filter housing for leaks. In the event
of leaks, check the seat of the screw. Renew the seal, if needed.

Check the water level in the tank. Add some water, if needed.

Placing out of Operation


-

Isolate the water cooling pump from the


power supply. See Safety Measures.

Unplug the electric connectors.

Dismount the cooling hoses.

Unscrew the drain cap. Drain the cooling liquid.


Catch it in a suitable container.

Screw the drain cap back on again.

Copyright by GE Sensing & Inspection Technologies GmbH

Bogenstrasse 41 22926 Ahrensburg

01/23/2009
1. Edition, ID No.: 2540570/EB.0109

Operating Instructions WL 5000 SE


6

Flow Chart

Copyright by GE Sensing & Inspection Technologies GmbH

01/23/2009
1. Edition, ID No.: 2540570/EB.0109

Bogenstrasse 41 22926 Ahrensburg

Operating Instructions WL 5000 SE


7

Technical Data
Dimensions and Weights
Length
Width
Height
Weight
Tank capacity
*)

483 mm
406 mm
481 mm
Approximately 38.5 kg without water
Approximately 5.0 l*)

In case of frost, use a mixture of drinking water and antifreeze (see Chapter 2 Description).

Output Data
Cooling output
Circulation rate
Mains voltage
Power input
Noise level

5000 W (T 13,2 K)
6,5 l/min at 3,0 bar
230 V +/- 10%, 50/60 Hz
2,6 A
63 dB (A) at 50 Hz, measured at a 1 m distance
67 dB (A) at 60 Hz, measured at a 1 m distance

Environmental Conditions
Operating temperature range
Storage temperature range
Relative air humidity range

-10C +40C (with sufficient antifreeze)


-25C +70C (storage without water)
20% 90%

Settings
Maximum pressure

7,0 bar 0,2 bar

Power diagram WL 5000 SE

20.0

Temperature difference between ambient air


and forward water temperature

18.0
16.0
14.0
12.0
10.0
8.0
6.0
4.0
2.0
0.0
0

500

1000

1500

2000

2500

3000

3500

4000

Power

Copyright by GE Sensing & Inspection Technologies GmbH

10

4500

5000

5500
W

Bogenstrasse 41 22926 Ahrensburg

01/23/2009
1. Edition, ID No.: 2540570/EB.0109

Operating Instructions WL 5000 SE


8

Spare Parts
Item

ID-Number

pump complete

9456840

drain cap

9456880

Flachdichtung aus Perbunan,

9456890

4 thermostat

9396850

cap

9456850

motor

9396860

toothed ring for clutch

9396870

fan

9456860

capacitor f. fan

9078100

10 filter

9396900

11 turbine flow rate monitor EKS3

9350820

12 plug-on electronics

9407300

Copyright by GE Sensing & Inspection Technologies GmbH

01/23/2009
1. Edition, ID No.: 2540570/EB.0109

Bogenstrasse 41 22926 Ahrensburg

11

12

Copyright by GE Sensing & Inspection Technologies GmbH

-C2

-M1

Legende

WH

BK

-M2

BK BN BU

-X1.

-C1

C1 Kondensator / capacitor
C2 Funk-Entstrkondensator / radio interf
C3 Funk-Entstrkondensator / radio interf
M1 Pumpe / pump
M2 Lfter / fan

B1 Temperatur max. / temperature max


B2 Strmungswchter / flow sw
switch

L1

Stromlaufplan
wiring diagram

itch

ESK3-RR.10

BU

BN

.
3

-B2

-C3

BK

BK

.
4

suppression capacitor
suppression capacitor

Sich erheitskreis
safe ty circuit

erence
erence

-X1

-B1

-C1

Str mungswchter

-B1

-M2

-M1
BK

BK

BK

RD

BN

BU

BU

WH

BN

BK

BK

L1

L1

L1

L1

-X1

plug

BK

BK

GY

BU

BK

BN

BK

.
1
3

.
2

-C3

-C2

GNYE

PE

M16 - Stecker

Sicherheitskreis
safety circuit

-B2

Klemmenplan
terminal connection table

Operating Instructions WL 5000 SE

Circuit Diagram

Bogenstrasse 41 22926 Ahrensburg

01/23/2009
1. Edition, ID No.: 2540570/EB.0109

Operating Instructions WL 5000 SE

Copyright by GE Sensing & Inspection Technologies GmbH

01/23/2009
1. Edition, ID No.: 2540570/EB.0109

Bogenstrasse 41 22926 Ahrensburg

13

Operating Instructions WL 5000 SE

GE Sensing & Inspection Technologies, please contact:


Service Department
Tel.:+49 (0)4102 807-117
Fax:+49 (0)4102 807-277

GE
Sensing & Inspection Technologies

GE Sensing & Inspection Technologies GmbH


Bogenstrasse 41 22926 Ahrensburg Germany
www.gesensininspection.com
Tel.: +49 (0)4102/807-0
Fax: +49 (0)4102/807-189

Im Interesse der Weiterentwicklung unserer Gerte Behalten wir uns das Recht auf nderungen von Daten und Konstruktionen ohne vorherige Mitteilung vor.
Looking for technical improvements, we reserve the right to technical modifications without prior notice.

Printed in Germany

S-ar putea să vă placă și