Sunteți pe pagina 1din 6

DVS

Submersible Effluent / Waste Pump

DVS

Submersible Effluent / Waste Pump

DIMENSION WITH QDC

DIMENSION WITH QDC

Applicable Models - 50 DVS

Applicable Models - 65 & 80 DVS

PUMP
Note:

Note:

1/. For detailed dimensions of the


pumps, refer to separate dimension
data sheets.

1/. For detailed dimensions of the


pumps, refer to separate dimension
data sheets.

2/. The discharge bend and


companion flange supplied with the
pump are used with the QDC.

2/. The companion flange supplied


with the pump are used with the
QDC.

3/. The weight in dimension tables


refers only to the weight of the
QDC.

3/. The weight in dimension tables


refers only to the weight of the
QDC.

4/. Standard accessories supplied


with QDC include:-Connector body with
foundation bolts.
-Guide pipe support
-Sliding Glide
-Adaptor Flange
Guide pipe is not supplied.

4/. Standard accessories supplied


with QDC include:-Connector body with
foundation bolts
-Guide rail support
-Adaptor Flange
Guide rail is not supplied.

Submersible Effluent / Waste Pump


Type DVS

APPLICATIONS

Ideal for waste water application containing soft or brous solids


Industrial waste water drainage
Septic effluent
Other drainage operation

FEATURES/BENEFITS

DA DE
65
80

Pump Model

Pump Model

DA1

DE

DF

DG

L1

L6

QDC
Model

QDC
Weight
kg

DF DG DT DN DD

140 175 116


150 185 126

18
18

4
8

15
15

D1

E1

QDC
QDC
Weight
Model
kg

95

12

140

LM65

14

95

12

140

LM65

14

75

95

12

140

LM65

14

49

75

95

12

140

LM65

14

P1

P2

G1

G2

H1

H2

H3

L1

L6

BN1 BN2

65 DVS 5.75T

363

75

95

120

160

250

145

190

240

125

72

75

65 DVS 51.5

363

75

95

120

160

250

145

190

240

125

72

75

65 DVS 52.2

394

75

95

120

160

250

145

190

240

155

49

65 DVS 53.7

394

75

95

120

160

250

145

190

240

155

50 DVS 5.4S

311

50

96

114

76

105

58

LS50

80 DVS 5.75T

363

75

95

120

170

255

145

190

240

125

72

75

95

12

140

LM65

14

50 DVS 5.75S

321

50

96

114

76

105

58

LS50

80 DVS 51.5

363

75

95

120

170

255

145

190

240

125

72

75

95

12

140

LM65

14

80 DVS 52.2

394

75

95

120

170

255

145

190

240

155

49

75

95

12

140

LM65

14

80 DVS 53.7

394

75

95

120

170

255

145

190

240

155

49

75

95

12

140

LM65

14

50 DVS 5.4T

311

50

96

114

76

105

58

LS50

50 DVS 5.75T

321

50

96

114

76

105

58

LS50

50 DVS 51.5

321

50

96

114

76

105

58

LS50

Units: mm unless otherwise specied

Units: mm unless otherwise specied


* Dimensional details are provided for reference only.
* All specifications are subject to change without prior notice.

Authorised dealer:

EBARA Pumps Malaysia Sdn Bhd


6, Jalan TP3, UEP Subang Jaya Industrial Park,
47620 Subang Jaya, Selangor, Malaysia.
Tel : 03-8023 6622 Fax : 03-8023 9355
Email : sales@ebara.com.my
Website : www.ebara.com.my
EPM DVS 0513

Air filled, Class F insulated, heavy duty motor, dissipates heat easily, operates cooler with higher
efficiencies; longer service life with lower operating costs.

Built-in motor protection with autocut, protects motor against overheating, single phasing,
and no load; saves money on costly motor replacement.

Molded cable prevents capillary action; reduces maintenance costs.

High quality stainless steel shaft; provides high tensile strength, corrosion
resistance, longer life, and lower maintenance costs.

Double mechanical seals-silicon carbide lower seals,


carbon/ceramic upper - hard faced upper and
lower seals operate in an oil bath; providing longer
service life and lower maintenance costs.

Available for Q.D.C connection installations


provides ease of maintenance for
sump type installations.

Large solids handling capabilities prevents clogging.


Semi-open vortex type recessed impeller; vortex action prevents clogging and
handles stringy material better, high reliability, and lowers maintenance costs.

DVS

Submersible Effluent / Waste Pump


PERFORMANCE CHART

The DVS model pump has a unique semi-vortex construction of EBARAs own design. This pump is as
efcient as a conventional non-clog pump which uses the centrifugal force of eddy A (see below) to pump
liquids. As you can see, any foreign matter sucked into the pump must pass the impeller, which can result in
trouble caused by clinging grass and clogged stones.

30
20

DVS
* 50 DVSA 51.5
DVSJ

15

Total head : m

DVS
65
* 80 DVSA51.5
DVSJ

DVS 5.4
* 50 DVSA 5.4S
DVSJ

DVS
65
* 80 DVSA5.75
DVSJ

DVS

Submersible Effluent / Waste Pump


DIMENSION

With the vortex pump, foreign matter is expelled by the force of eddy B which is formed in the wide space
between the impeller and the suction cover (C). There is less likelihood of clogging.

* 65 DV
80 D S
V
DV SA
SJ 53.
7

S
2.2
DV SA5
V
65 D SJ
* 80 DV

DVS 5.75
* 50 DVSA 5.75S
DVSJ

10
9
8
7
6

DVS

Submersible Effluent / Waste Pump

EBARA semi - vortex pump

Model Code
50 DVS 5

.25

Conventional non - clog pump

T
Phase S: Single
No mark: Three

Motor output: kW

Frequency 50Hz: 5
Model DVS : Manual type
DVSA : Automatic type
DVSJ : Parallel Automatic
Device type
Size: mm

1
0.01

0.02

0.03

0.05

0.1

0.2

0.3

0.5

1.0

SECTIONAL VIEW

Capacity : m3/min
Note:
DVSH models for hot water are limited to asterisk* marked, 3 phase pumps only.

SPECIFICATIONS
Pump
Type of liquid
Liquid
Temperature
Handled
Pump size : Max solids size
Maximum Submergence
Minimum Submergence

River water, efuent


0C ~ 40C for DVS, DVSA; 0C ~ 32C for DVSJ
50 : 32mm, 65 (80) : 45mm or 56mm.
4m (0.4 ~ 1.5kW) ; 8m (2.2, 3.7kW)
Refer to water level (L.W.L) in dimensions.
It is possible to operate at low water level for 30min.

Synchronous Speed

3000min-1
Double mechanical seal
Semi-Vortex
Prelubricated bearing
Cast iron
Cast iron
403 Stainless steel
Silicon carbide
Ceramic / Carbon
NBR

Construction

Material

Mechanical seal
Impeller
Bearing
Casing
Imp eller
Shaft
Mechanical
seal
Pac king

Impeller side
Motor side

Note:

Size

50

Motor
2 pole, air-lled watertight

POS

Insulation

Class F

001

Casing

Protection

Built-in thermal protector


016

Mechanical Seal Cover

021

Impeller

048
111

Impeller Nut
Mechanical Seal

174

Discharge Bend

Standard
Optional

Submersible cable : 0.4 ~ 1.5kW x 6m, 2.2 ~ 3.7kW x 10m


Float switch (for DVSA, DVSJ)
Quick discharge connector, leakage detector.

DA
65
80

2/. Is limited to 30 minutes operation


with water level below top of motor.

Type

Accessories

Discharge Flange Dimensions


(JIS 10kgf/cm)

1/. L.W.L (Low Water Level)


Is limited to 10 minutes operation
at low water level.

PART NAME

MATERIAL
Cast Iron
EN-GHJL-200-EN 1561
Cast Iron
EN-GHJL-200-EN 1561
Cast Iron
EN-GHJL-200-EN 1561
EN 1.4301 (AISI304)
Cast Iron
EN-GHJL-200-EN 1561
NBR/EN 1.4301
(AISI304)

N FOR
UNIT

POS

814

Motor Frame

816

Power Side Bracket

830

Shaft

1
1

842

Motor Cover

849-1 Ball Bearing

849-2 Ball Bearing

876

Protector

904

Lifting Hanger

Stainless Steel

908

Spacer

Steel

193

Oil Plug

801

Rotor

Silicon Steel Sheet

802

Stator

Silicon Steel Sheet

811

Cable

Silicon Steel Sheet

PART NAME

MATERIAL
Cast Iron
EN-GHJL-200-EN 1561
Cast Iron
EN-GHJL-200-EN 1561
EN-GHJL-200-EN 1561
Cast Iron
EN-GHJL-200-EN 1561

N FOR
UNIT

65

1
1
1
1

80

Model
50 DVS 5.4S
50 DVS 5.4T
50 DVS 5.75S
50 DVS 5.75T
50 DVS 51.5
65 DVS 5.75T
65 DVS 51.5
65 DVS 52.2
65 DVS 53.7
80 DVS 5.75T
80 DVS 51.5
80 DVS 52.2
80 DVS 53.7

Fig. Output
KW Phase DA

1
1
1
1
1
2
2
2
2
2
2
2
2

0.4
0.4
0.75
0.75
1.5
0.75
1.5
2.2
3.7
0.75
1.5
2.2
3.7

1
3
1
3
3
3
3
3
3
3
3
3
3

PT2
PT2
PT2
PT2
PT2
65
65
65
65
80
80
80
80

A
239
239
249
249
249
396
396
427
427
411
411
442
442

B
160
160
171
171
171
195
195
227
227
195
195
227
227

C
148
148
163
163
163
298
298
313
313
313
313
328
328

D
91
91
86
86
86
98
98
114
114
98
98
114
114

E
110
110
125
125
125
210
210
225
225
220
220
235
235

F
82
82
82
82
82
178
178
201
201
183
183
206
206

DE
140
150

H
435
398
497
397
439
467
519
643
643
467
519
643
643

DE
96
96
96
96
96
-

DF DG
175 116
185 126

J
145
145
160
160
145
145
160
160

L1
105
105
105
105
105
125
125
155
155
125
125
155
155

DT
18
18

DN
4
8

DD
15
15

CL Weight
6 m 18 kg
6 m 17 kg
6 m 26 kg
6 m 19 kg
6 m 27 kg
6 m 25 kg
6 m 34 kg
10m 50 kg
10m 59 kg
6 m 26 kg
6 m 35 kg
10m 51 kg
10m 60 kg

Units: mm unless otherwise specied

DVS

Submersible Effluent / Waste Pump

The DVS pump has a unique semi-vortex construction of EBARAs own design. This pump is as efcient as
conventional non-clog pump which uses the centrifugal force of eddy A (see below) to pump liquids. As you
can see, any foreign matter sucked into the pump must pass the impeller, which can result in trouble caused
by clinging grass and clogged stones.

PERFORMANCE CHART
30
20

DVS
* 50 DVSA 51.5
DVSJ

15

Total head : m

DVS
65
* 80 DVSA51.5
DVSJ

DVS 5.4
* 50 DVSA 5.4S
DVSJ

DVS
65
* 80 DVSA5.75
DVSJ

DVS

Submersible Effluent / Waste Pump


DIMENSION

With the vortex pump, foreign matter is expelled by the force of eddy B which is formed in the wide space
between the impeller and the suction cover (C). There is less likelihood of clogging.

* 65 DV
80 D S
V
DV SA
SJ 53.
7

S
2.2
DV SA5
V
65 D SJ
* 80 DV

DVS 5.75
* 50 DVSA 5.75S
DVSJ

10
9
8
7
6

DVS

Submersible Effluent / Waste Pump

EBARA semi - vortex pump

Model Code
50 DVS 5

.25

Conventional non - clog pump

Phase S: Single
No mark: Three

Motor output: kW

Frequency 50Hz: 5
Model DVS : Manual type
DVSA : Automatic type
DVSJ : Parallel Automatic
Device type
Size: mm

1
0.01

0.02

0.03

0.05

0.1

0.2

0.3

0.5

1.0

SECTIONAL VIEW

Capacity : m3/min
Note:
DVSH models for hot water are limited to asterisk* marked, 3 phase pumps only.

SPECIFICATIONS
Note:

Pump
Type of liquid
Liquid
Temperature
Handled
Pump size : Max solids size
Maximum Submergence
Minimum Submergence

River water, efuent


0C ~ 40C for DVS, DVSA; 0C ~ 32C for DVSJ
50 : 32mm, 65 (80) : 45mm or 56mm.
4m (0.4 ~ 1.5kW) ; 8m (2.2, 3.7kW)
Refer to water level (L.W.L) in dimensions.
It is possible to operate at low water level for 30min.

Synchronous Speed

3000min-1
Double mechanical seal
Semi-Vortex
Prelubricated bearing
Cast iron
Cast iron
403 Stainless steel
Silicon carbide
Ceramic / Carbon
NBR

Construction

Material

Mechanical seal
Impeller
Bearing
Casing
Imp eller
Shaft
Mechanical
seal
Pac king

Impeller side
Motor side

Impeller of DVS
2/. Is limited to 30 minutes operation
with water level below top of motor.

Size

50

Motor
Type

2 pole, air-lled watertight

POS

Insulation

Class F

001

Protection

Built-in thermal protector

Accessories
Standard
Optional

Submersible cable : 0.4 ~ 1.5kW x 6m, 2.2 ~ 3.7kW x 10m


Float switch (for DVSA, DVSJ)
Quick discharge connector, leakage detector.

Discharge Flange Dimensions


(JIS 10kgf/cm)

1/. L.W.L (Low Water Level)


Is limited to 10 minutes operation
at low water level.

PART NAME
Casing

MATERIAL
Cast Iron
EN-GHJL-200-EN 1561
Cast Iron
EN-GHJL-200-EN 1561
Cast Iron
EN-GHJL-200-EN 1561
EN 1.4301 (AISI304)
Cast Iron
EN-GHJL-200-EN 1561
NBR/EN 1.4301
(AISI304)

N FOR
UNIT

POS

814

016

Mechanical Seal Cover

021

Impeller

048
111

Impeller Nut
Mechanical Seal

174

Discharge Bend

193

Oil Plug

801

Rotor

Silicon Steel Sheet

802

Stator

Silicon Steel Sheet

811

Cable

Submersible type

PART NAME
Motor Frame

MATERIAL
Cast Iron
EN-GHJL-200-EN 1561
Cast Iron
EN-GHJL-200-EN 1561

N FOR
UNIT

816

Power Side Bracket

830

Shaft

EN-GHJL-200-EN 1561

1
1

842

Motor Cover

Cast Iron
EN-GHJL-200-EN 1561

1
1

849-1 Ball Bearing

65

1
1

849-2 Ball Bearing

876

Protector

904

Lifting Hanger

Stainless Steel

908

Spacer

Steel

80

Model

Fig.

Output
Phase
KW

DA
65
80

DE
140
150

DF DG
175 116
185 126

DT
18
18

DN
4
8

DD
15
15

DA

DE

L1

CL
(m)

Weight
kg

0.4

PT2

239

160

148

91

110

82

435

96

105

18

0.4

PT2

239

160

148

91

110

82

398

96

105

17

0.75

PT2

249

171

163

86

125

82

497

96

105

26

50 DVS 5.75T

0.75

PT2

249

171

163

86

125

82

397

96

105

19

50 DVS 51.5

1.5

PT2

249

171

163

86

125

82

439

96

105

27

65 DVS 5.75T

0.75

65

396

195

298

98

210

178

467

145

125

25

65 DVS 51.5

1.5

65

396

195

298

98

210

178

519

145

125

34

65 DVS 52.2

2.2

65

427

227

313

114

225

201

643

160

155

10

50

65 DVS 53.7

3.7

65

427

227

313

114

225

201

643

160

155

10

59

80 DVS 5.75T

0.75

80

411

195

313

98

220

183

467

145

125

26

80 DVS 51.5

1.5

80

411

195

313

98

220

183

519

145

125

35

80 DVS 52.2

2.2

80

442

227

328

114

235

206

643

160

155

10

51

80 DVS 53.7

3.7

80

442

227

328

114

235

206

643

160

155

10

60

50 DVS 5.4S

50 DVS 5.4T
50 DVS 5.75S

Units: mm unless otherwise specied

DVS

Submersible Effluent / Waste Pump

The DVS pump has a unique semi-vortex construction of EBARAs own design. This pump is as efcient as
conventional non-clog pump which uses the centrifugal force of eddy A (see below) to pump liquids. As you
can see, any foreign matter sucked into the pump must pass the impeller, which can result in trouble caused
by clinging grass and clogged stones.

PERFORMANCE CHART
30
20

DVS
* 50 DVSA 51.5
DVSJ

15

Total head : m

DVS
65
* 80 DVSA51.5
DVSJ

DVS 5.4
* 50 DVSA 5.4S
DVSJ

DVS
65
* 80 DVSA5.75
DVSJ

DVS

Submersible Effluent / Waste Pump


DIMENSION

With the vortex pump, foreign matter is expelled by the force of eddy B which is formed in the wide space
between the impeller and the suction cover (C). There is less likelihood of clogging.

* 65 DV
80 D S
V
DV SA
SJ 53.
7

S
2.2
DV SA5
V
65 D SJ
* 80 DV

DVS 5.75
* 50 DVSA 5.75S
DVSJ

10
9
8
7
6

DVS

Submersible Effluent / Waste Pump

EBARA semi - vortex pump

Model Code
50 DVS 5

.25

Conventional non - clog pump

Phase S: Single
No mark: Three

Motor output: kW

Frequency 50Hz: 5
Model DVS : Manual type
DVSA : Automatic type
DVSJ : Parallel Automatic
Device type
Size: mm

1
0.01

0.02

0.03

0.05

0.1

0.2

0.3

0.5

1.0

SECTIONAL VIEW

Capacity : m3/min
Note:
DVSH models for hot water are limited to asterisk* marked, 3 phase pumps only.

SPECIFICATIONS
Note:

Pump
Type of liquid
Liquid
Temperature
Handled
Pump size : Max solids size
Maximum Submergence
Minimum Submergence

River water, efuent


0C ~ 40C for DVS, DVSA; 0C ~ 32C for DVSJ
50 : 32mm, 65 (80) : 45mm or 56mm.
4m (0.4 ~ 1.5kW) ; 8m (2.2, 3.7kW)
Refer to water level (L.W.L) in dimensions.
It is possible to operate at low water level for 30min.

Synchronous Speed

3000min-1
Double mechanical seal
Semi-Vortex
Prelubricated bearing
Cast iron
Cast iron
403 Stainless steel
Silicon carbide
Ceramic / Carbon
NBR

Construction

Material

Mechanical seal
Impeller
Bearing
Casing
Imp eller
Shaft
Mechanical
seal
Pac king

Impeller side
Motor side

2/. Is limited to 30 minutes operation


with water level below top of motor.

Size

50

Motor
Type

2 pole, air-lled watertight

POS

Insulation

Class F

001

Protection

Built-in thermal protector

Accessories
Standard
Optional

Submersible cable : 0.4 ~ 1.5kW x 6m, 2.2 ~ 3.7kW x 10m


Float switch (for DVSA, DVSJ)
Quick discharge connector, leakage detector.

Discharge Flange Dimensions


(JIS 10kgf/cm)

1/. L.W.L (Low Water Level)


Is limited to 10 minutes operation
at low water level.

PART NAME
Casing

MATERIAL
Cast Iron
EN-GHJL-200-EN 1561
Cast Iron
EN-GHJL-200-EN 1561
Cast Iron
EN-GHJL-200-EN 1561
EN 1.4301 (AISI304)
Cast Iron
EN-GHJL-200-EN 1561
NBR/EN 1.4301
(AISI304)

N FOR
UNIT

POS

814

016

Mechanical Seal Cover

021

Impeller

048
111

Impeller Nut
Mechanical Seal

174

Discharge Bend

193

Oil Plug

801

Rotor

Silicon Steel Sheet

802

Stator

Silicon Steel Sheet

811

Cable

Submersible type

PART NAME
Motor Frame

MATERIAL
Cast Iron
EN-GHJL-200-EN 1561
Cast Iron
EN-GHJL-200-EN 1561

N FOR
UNIT

816

Power Side Bracket

830

Shaft

EN-GHJL-200-EN 1561

1
1

842

Motor Cover

Cast Iron
EN-GHJL-200-EN 1561

1
1

849-1 Ball Bearing

65

1
1

849-2 Ball Bearing

876

Protector

904

Lifting Hanger

Stainless Steel

908

Spacer

Steel

80

Model

Fig.

Output
Phase
KW

DA
65
80

DE
140
150

DF DG
175 116
185 126

DT
18
18

DN
4
8

DD
15
15

DA

DE

L1

CL
(m)

Weight
kg

0.4

PT2

239

160

148

91

110

82

435

96

105

18

0.4

PT2

239

160

148

91

110

82

398

96

105

17

0.75

PT2

249

171

163

86

125

82

497

96

105

26

50 DVS 5.75T

0.75

PT2

249

171

163

86

125

82

397

96

105

19

50 DVS 51.5

1.5

PT2

249

171

163

86

125

82

439

96

105

27

65 DVS 5.75T

0.75

65

396

195

298

98

210

178

467

145

125

25

65 DVS 51.5

1.5

65

396

195

298

98

210

178

519

145

125

34

65 DVS 52.2

2.2

65

427

227

313

114

225

201

643

160

155

10

50

65 DVS 53.7

3.7

65

427

227

313

114

225

201

643

160

155

10

59

80 DVS 5.75T

0.75

80

411

195

313

98

220

183

467

145

125

26

80 DVS 51.5

1.5

80

411

195

313

98

220

183

519

145

125

35

80 DVS 52.2

2.2

80

442

227

328

114

235

206

643

160

155

10

51

80 DVS 53.7

3.7

80

442

227

328

114

235

206

643

160

155

10

60

50 DVS 5.4S

50 DVS 5.4T
50 DVS 5.75S

Units: mm unless otherwise specied

DVS

Submersible Effluent / Waste Pump

DVS

Submersible Effluent / Waste Pump

DIMENSION WITH QDC

DIMENSION WITH QDC

Applicable Models - 50 DVS

Applicable Models - 65 & 80 DVS

PUMP
Note:

Note:

1/. For detailed dimensions of the


pumps, refer to separate dimension
data sheets.

1/. For detailed dimensions of the


pumps, refer to separate dimension
data sheets.

2/. The discharge bend and


companion flange supplied with the
pump are used with the QDC.

2/. The companion flange supplied


with the pump are used with the
QDC.

3/. The weight in dimension tables


refers only to the weight of the
QDC.

3/. The weight in dimension tables


refers only to the weight of the
QDC.

4/. Standard accessories supplied


with QDC include:-Connector body with
foundation bolts.
-Guide pipe support
-Sliding Glide
-Adaptor Flange
Guide pipe is not supplied.

4/. Standard accessories supplied


with QDC include:-Connector body with
foundation bolts
-Guide rail support
-Adaptor Flange
Guide rail is not supplied.

Submersible Effluent / Waste Pump


Type DVS

APPLICATIONS

Ideal for waste water application containing soft or brous solids


Industrial waste water drainage
Septic effluent
Other drainage operation

FEATURES/BENEFITS

DA DE
65
80

Pump Model

DF DG DT DN DD

140 175 116


150 185 126

18
18

4
8

15
15

D1

E1

QDC
QDC
Weight
Model
kg

95

12

140

LM65

14

75

95

12

140

LM65

14

49

75

95

12

140

LM65

14

P1

P2

G1

G2

H1

H2

H3

L1

L6

BN1 BN2

65 DVS 5.75T

363

75

95

120

160

250

145

190

240

125

72

75

65 DVS 51.5

363

75

95

120

160

250

145

190

240

125

72

65 DVS 52.2

394

75

95

120

160

250

145

190

240

155

DA1

DE

DF

DG

L1

L6

QDC
Model

QDC
Weight
kg

65 DVS 53.7

394

75

95

120

160

250

145

190

240

155

49

75

95

12

140

LM65

14

50 DVS 5.4S

311

50

96

114

76

105

58

LS50

80 DVS 5.75T

363

75

95

120

170

255

145

190

240

125

72

75

95

12

140

LM65

14

50 DVS 5.75S

321

50

96

114

76

105

58

LS50

80 DVS 51.5

363

75

95

120

170

255

145

190

240

125

72

75

95

12

140

LM65

14

80 DVS 52.2

394

75

95

120

170

255

145

190

240

155

49

75

95

12

140

LM65

14

80 DVS 53.7

394

75

95

120

170

255

145

190

240

155

49

75

95

12

140

LM65

14

Pump Model

50 DVS 5.4T

311

50

96

114

76

105

58

LS50

50 DVS 5.75T

321

50

96

114

76

105

58

LS50

50 DVS 51.5

321

50

96

114

76

105

58

LS50

Units: mm unless otherwise specied

Units: mm unless otherwise specied


* Dimensional details are provided for reference only.
* All specifications are subject to change without prior notice.

Authorised dealer:

EBARA Pumps Malaysia Sdn Bhd


6, Jalan TP3, UEP Subang Jaya Industrial Park,
47620 Subang Jaya, Selangor, Malaysia.
Tel : 03-8023 6622 Fax : 03-8023 9355
Email : sales@ebara.com.my
Website : www.ebara.com.my
EPM DVS 0413

Air filled, Class F insulated, heavy duty motor, dissipates heat easily, operates cooler with higher
efficiencies; longer service life with lower operating costs.

Built-in motor protection with autocut, protects motor against overheating, single phasing,
and no load; saves money on costly motor replacement.

Molded cable prevents capillary action; reduces maintenance costs.

High quality stainless steel shaft; provides high tensile strength, corrosion
resistance, longer life, and lower maintenance costs

Double mechanical seals-silicon carbide lower seals,


carbon/ceramic upper - hard faced upper and
lower seals operate in an oil bath; providing longer
service life and lower maintenance costs.

Available for Q.D.C Connection, provides ease


of maintenance for sump installations.

Large solids handling capabilities prevents clogging.


Open semi-vortex type recessed impeller; vortex action prevents clogging and
handles stringy material better then moving pump age through impeller vanes;
provides durability, high reliability, and lowers maintenance costs.

DVS

Submersible Effluent / Waste Pump

DVS

Submersible Effluent / Waste Pump

DIMENSION WITH QDC

DIMENSION WITH QDC

Applicable Models - 50 DVS

Applicable Models - 65 & 80 DVS

PUMP
Note:

Note:

1/. For detailed dimensions of the


pumps, refer to separate dimension
data sheets.

1/. For detailed dimensions of the


pumps, refer to separate dimension
data sheets.

2/. The discharge bend and


companion flange supplied with the
pump are used with the QDC.

2/. The companion flange supplied


with the pump are used with the
QDC.

3/. The weight in dimension tables


refers only to the weight of the
QDC.

3/. The weight in dimension tables


refers only to the weight of the
QDC.

4/. Standard accessories supplied


with QDC include:-Connector body with
foundation bolts.
-Guide pipe support
-Sliding Glide
-Adaptor Flange
Guide pipe is not supplied.

4/. Standard accessories supplied


with QDC include:-Connector body with
foundation bolts
-Guide rail support
-Adaptor Flange
Guide rail is not supplied.

Submersible Effluent / Waste Pump


Type DVS

APPLICATIONS

Ideal for waste water application containing soft or brous solids


Industrial waste water drainage
Septic effluent
Other drainage operation

FEATURES/BENEFITS

DA DE
65
80

Pump Model

DF DG DT DN DD

140 175 116


150 185 126

18
18

4
8

15
15

D1

E1

QDC
QDC
Weight
Model
kg

95

12

140

LM65

14

75

95

12

140

LM65

14

49

75

95

12

140

LM65

14

P1

P2

G1

G2

H1

H2

H3

L1

L6

BN1 BN2

65 DVS 5.75T

363

75

95

120

160

250

145

190

240

125

72

75

65 DVS 51.5

363

75

95

120

160

250

145

190

240

125

72

65 DVS 52.2

394

75

95

120

160

250

145

190

240

155

DA1

DE

DF

DG

L1

L6

QDC
Model

QDC
Weight
kg

65 DVS 53.7

394

75

95

120

160

250

145

190

240

155

49

75

95

12

140

LM65

14

50 DVS 5.4S

311

50

96

114

76

105

58

LS50

80 DVS 5.75T

363

75

95

120

170

255

145

190

240

125

72

75

95

12

140

LM65

14

50 DVS 5.75S

321

50

96

114

76

105

58

LS50

80 DVS 51.5

363

75

95

120

170

255

145

190

240

125

72

75

95

12

140

LM65

14

80 DVS 52.2

394

75

95

120

170

255

145

190

240

155

49

75

95

12

140

LM65

14

80 DVS 53.7

394

75

95

120

170

255

145

190

240

155

49

75

95

12

140

LM65

14

Pump Model

50 DVS 5.4T

311

50

96

114

76

105

58

LS50

50 DVS 5.75T

321

50

96

114

76

105

58

LS50

50 DVS 51.5

321

50

96

114

76

105

58

LS50

Units: mm unless otherwise specied

Units: mm unless otherwise specied


* Dimensional details are provided for reference only.
* All specifications are subject to change without prior notice.

Authorised dealer:

EBARA Pumps Malaysia Sdn Bhd


6, Jalan TP3, UEP Subang Jaya Industrial Park,
47620 Subang Jaya, Selangor, Malaysia.
Tel : 03-8023 6622 Fax : 03-8023 9355
Email : sales@ebara.com.my
Website : www.ebara.com.my
EPM DVS 0513

Air filled, Class F insulated, heavy duty motor, dissipates heat easily, operates cooler with higher
efficiencies; longer service life with lower operating costs.

Built-in motor protection with autocut, protects motor against overheating, single phasing,
and no load; saves money on costly motor replacement.

Molded cable prevents capillary action; reduces maintenance costs.

High quality stainless steel shaft; provides high tensile strength, corrosion
resistance, longer life, and lower maintenance costs

Double mechanical seals-silicon carbide lower seals,


carbon/ceramic upper - hard faced upper and
lower seals operate in an oil bath; providing longer
service life and lower maintenance costs.

Available for Q.D.C Connection, provides ease


of maintenance for sump installations.

Large solids handling capabilities prevents clogging.


Open semi-vortex type recessed impeller; vortex action prevents clogging and
handles stringy material better then moving pump age through impeller vanes;
provides durability, high reliability, and lowers maintenance costs.

S-ar putea să vă placă și