3/2 DIRECT ACTING NAMUR SOLENOID VALVE


TYPE PRESSURE TYPE PRESSURE TYPE PRESSURE TYPE PRESSURE
4

30106

0-10 bar

30107

0-10 bar

NC
3

5
1

DIMENSIONS

Actuator spring side vent port.

CONNECTIONS
TYPE

INLET OUTLET OUTLET EXHAUST EXHAUST

30106,30107

4 *

FEATURES
High pressure model can be supplied.
Special version may be developed on request.
Accessories for mounting the Solenoid Valve on the Actuator
are provided.
Solenoid of any voltage rating/construction can be replaced at
customers end.

Normally Closed.
Manual override push to operate & turn to lock is standard.
Suitable for air, gases, water, oil, etc;
Ideally suited for Spring Return Actuator on ON / OFF &
Control duty.

ORDERING CODE
VALVE CODE

TYPE SUFFIX
PRESSURE

30106
ORIFICE

30107

PORT CONNECTION

BODY &
INTERNAL

MANUAL
OVERRIDE

SEAL

kv
kv
ORIFICE
lpm@1bar
lpm@1bar

SIZE

BSP

BODY

NPT

CODE

Aluminium

NBR

Push & Turn


Nil

0 - 10

1.8

1.8

3.0

4.0

EPDM

S1

0-8

2.2

2.5

3.5

5.0

Brass

B2

VITON

S2

0-6

2.5

3.5

4.0

7.0

SS304

B4

NEOPRENE S3

0-4

3.0

4.0

4.0

7.0

SS316

B5

2G

1/4

2R

M0

SOLENOID CODE

VOLTAGE CURRENT

CONSTRUCTION

12

50Hz

24

60HZ

GENERAL PURPOSE / WEATHERPROOF

48

DC

TYPE

CODE

110

Flying Lead IP 67

01

125

Terminal Box 3/4 ET, IP 67

15

220

Terminal Box 1/2NPT, IP 67

16

240

Terminal Box M20 x 1.5, IP 67

14

Plug in, Pg9, IP 67

25

Plug in, Pg9, IP 67 with LED

22

Need not be specified while ordering.

INSULATION

SPECIAL VERSION
NIL

Cable entry

CLASS H H

Manual Reset

MR

3/4 ET NPT M20 x 1.5

CLASS C C

Ammonia

AM

Intrinsically Safe

IS

52

Refinery

PC

57

Temp. Class T6

T6

Low Power

LW

TYPE

FLYING CABLE, IP 67
50

IIC

CLASS F

FLAMEPROOF (IP 67)

IIA, IIB

55

51
56

JUNCTION BOX WITH LED, IP 67


IIA, IIB (Side entry)

34

35

38

Corrosive Environment CO

IIC (Side entry)

36

37

39

Nuclear

63

64

NP

INTRINSICALLY SAFE IP 67
NOTE : voltage 24V DC only

ORDERING EXAMPLE
Standard Version
Special Version

62

30106-1.8-2G+24V-DC-22
30106PC-1.8-2G+24V-DC-35

Specifications are subject to change without notice.

E Ex ia (Side entry)

Refer page no.14 for suggested application.

FLUID CONTROL SYSTEM

3/2 DIRECT ACTING WITH BUILTIN QUICK EXHAUST 5mm NAMUR SOLENOID VALVE
TYPE PRESSURE

TYPE PRESSURE TYPE PRESSURE TYPE PRESSURE


2

30120
30121

0-10 bar

NC

0-10 bar

DIMENSIONS

Actuator spring side vent port.

CONNECTIONS
TYPE

PILOT
VENT

INLET OUTLET OUTLET EXHAUST EXHAUST

30120,30121

4 *

3
6

FEATURES
Inbuilt Quick Exhausting Mechanism for quick shutdown of
Actuator.
Exhaust Orifice 5mm(kv =12 lpm@1bar).
Normally Closed.
Manual Override push to operate & turn to lock is standard.
Suitable for air, gases, water etc;

Ideally suited for Spring Return Actuator on ON/OFF duty.


Special version may be developed on request.
Accessories for mounting the Solenoid Valve on the Actuator
are provided.
Solenoid of any voltage rating/construction can be replaced at
customers end.

ORDERING CODE
VALVE CODE

TYPE SUFFIX
PRESSURE

30120

30121

PORT CONNECTION

BODY &
INTERNAL

MANUAL
OVERRIDE

SEAL

kv
kv
ORIFICE lpm@1bar ORIFICE lpm@1bar

SIZE

BSP

NPT

1/4

2G

2R

BODY

CODE

Aluminium

Push & Turn


Nil

NBR

0 - 10

1.8

1.8

3.0

4.0

EPDM

S1

0-8

2.2

2.5

3.5

5.0

Brass

B2

VITON

S2

0-6

2.5

3.5

4.0

7.0

SS304

B4

NEOPRENE S3

0-4

3.0

4.0

4.0

7.0

SS316

B5

M0

SOLENOID CODE

VOLTAGECURRENT

CONSTRUCTION

12

50Hz

24

60HZ

GENERAL PURPOSE / WEATHERPROOF

48

DC

TYPE

CODE

INSULATION

SPECIAL VERSION
NIL

CLASS F

FLAMEPROOF (IP 67)


Cable entry

CLASS H H

Manual Reset

MR

3/4 ET NPT M20 x 1.5

CLASS C C

Ammonia

AM

Intrinsically Safe

IS

52

Refinery

PC

57

Temp. Class T6

T6

Low Power

LW

TYPE

110

Flying Lead IP 67

01

125

Terminal Box 3/4 ET, IP 67

15

220

Terminal Box 1/2NPT, IP 67

16

IIA, IIB

50

51

240

Terminal Box M20 x 1.5, IP 67

14

IIC

55

56

Plug in, Pg9, IP 67

25

Plug in, Pg9, IP 67 with LED

22

Need not be specified while ordering.

FLYING CABLE, IP 67

JUNCTION BOX WITH LED, IP 67


IIA, IIB (Side entry)

34

35

38

Corrosive Environment CO

IIC (Side entry)

36

37

39

Nuclear

63

64

NP

INTRINSICALLY SAFE IP 67

ORDERING EXAMPLE
Standard Version
Special Version

NOTE : voltage 24V DC only

E Ex ia (Side entry)
30120-2.2-2G+24V-DC-16
30121-4-2G-S1+220V-50Hz-35-H

Specifications are subject to change without notice.

62

Refer page no.14 for suggested application.

FLUID CONTROL SYSTEM

3/2 DIRECT ACTING HIGH ORIFICE, NAMUR, SOLENOID VALVE


TYPE PRESSURE TYPE PRESSURE TYPE PRESSURE TYPE PRESSURE
2

30318

0-10 bar

30319

0-10 bar

NC
1

DIMENSIONS

Actuator spring side vent port.

CONNECTIONS
TYPE

INLET OUTLET OUTLET EXHAUST

30318, 30319

4 *

FEATURES
Normally Closed
Manual Override push to operate & turn to lock is standard
High Flow Valve, kv = 9lpm@1bar for fast opening & closing.
Suitable for air, gases, water, etc;
Ideally suited for Spring Return Actuator on ON / OFF & control duty.
Exhaust purged to spring chamber.

Special version may be developed on request.


Accessories for mounting the Solenoid Valve on the Actuator
are provided.
Solenoid of any voltage rating/construction can be replaced at
customers end.

ORDERING CODE
VALVE CODE

TYPE ORIFICE kv(lpm@1bar)


30318
5.0
9
30319
7.0
14

PORT CONNECTION

TYPE SUFFIX

SIZE
1/4"

BSP
2G

NPT
2R

BODY & INTERNAL


BODY
Aluminium
Brass
SS304
SS316

d
CODE

SEAL

MANUAL OVERRIDE
Push & Turn
NIL

B2
B4
B5

MO

NBR
EPDM
VITON
NEOPRENE

S1
S2
S3

SOLENOID CODE

VOLTAGECURRENT

CONSTRUCTION

12

50Hz

24

60HZ

GENERAL PURPOSE / WEATHERPROOF

48

DC

TYPE

CODE

INSULATION

SPECIAL VERSION
NIL

CLASS F

FLAMEPROOF (IP 67)


Cable entry

CLASS H H

Manual Reset

MR

3/4 ET NPT M20 x 1.5

CLASS C C

Ammonia

AM

Intrinsically Safe

IS

52

Refinery

PC

57

Temp. Class T6

T6

Low Power

LW

TYPE

110

Flying Lead, IP 67

01

125

Terminal Box 3/4 ET, IP 67

15

220

Terminal Box 1/2NPT, IP 67

16

IIA, IIB

50

51

240

Terminal Box M20 x 1.5, IP 67

14

IIC

55

56

Plug in, Pg9, IP 67

25

Plug in, Pg9, IP 67 with LED

22

FLYING CABLE, IP 67

JUNCTION BOX WITH LED, IP 67


IIA, IIB (Side entry)

34

35

38

Corrosive Environment CO

IIC (Side entry)

36

37

39

Nuclear

63

64

NP

INTRINSICALLY SAFE IP 67

Need not be specified while ordering.

ORDERING EXAMPLE
Standard Version
Special Version

62

30318-5-2G+220V-50HZ-25-01
30319T6-7-2G-B4-S2+220V-50Hz-35-H

Specifications are subject to change without notice.

NOTE : voltage 24V DC only


E Ex ia (Side entry)

Refer page no.14 for suggested application.

FLUID CONTROL SYSTEM

3/2 INTERNAL / EXTERNAL PILOT OPERATED, POPPET TYPE,


NAMUR, SOLENOID VALVE
TYPE PRESSURE TYPE PRESSURE TYPE PRESSURE TYPE PRESSURE
31113

2-10 bar

32105

0-10 bar

2 4

NC
1

DIMENSIONS

Pilot pressure minimum 3 bar


or > media pressure, whichever
is higher.
Actuator spring side vent port.

CONNECTIONS
TYPE INLET OUTLET OUTLET EXHAUST

Photographed with Flameproof Solenoid

31113

4 *

32105

4 *

PILOT PILOT
PILOT
INLET VENT

INTERNAL

EXTERNAL

FEATURES
Air or Power failure to return.
Normally Closed.
High Flow Rate, kv=12 lpm@1bar, Fast Response Time.
Suitable for air, gases, water, etc;
Exhaust purged to spring chamber.
Accessories for mounting the Solenoid Valve on the Actuator
are provided.

Ideally suited for Spring Return Actuator on ON / OFF and control duty.
(Recommended on regulation duty for system requiring air failure and
power failure safety).
Special versions may be developed on request.
Solenoid of any voltage rating/construction can be replaced at
customers end.

ORDERING CODE
VALVE CODE

ORIFICE
6.0

PORT CONNECTION

TYPE SUFFIX

SIZE
1/4"

BSP
2G

BODY & INTERNAL


BODY
Aluminium
Brass
SS304
SS316

NPT
2R

SOLENOID CODE

CODE

Push & Turn


NIL

50Hz

24

60HZ

GENERAL PURPOSE / WEATHERPROOF

48

DC

TYPE

CODE

S1
S2
S3

INSULATION

SPECIAL VERSION
NIL

Cable entry

CLASS H H

Manual Reset

MR

3/4 ET NPT M20 x 1.5

CLASS C C

Ammonia

AM

Intrinsically Safe

IS

52

Refinery

PC

57

Temp. Class T6

T6

Low Power

LW

TYPE

Flying Lead, IP 67

01

125

Terminal Box 3/4 ET, IP 67

15

220

Terminal Box 1/2NPT, IP 67

16

IIA, IIB

50

51

240

Terminal Box M20 x 1.5, IP 67

14

IIC

55

56

Plug in, Pg9, IP 67

25

Plug in, Pg9, IP 67 with LED

22

Need not be specified while ordering.

NBR
EPDM
VITON
NEOPRENE

CLASS F

FLAMEPROOF (IP 67)

110

ORDERING EXAMPLE

MO

B2
B4
B5

CONSTRUCTION

12

SEAL

MANUAL OVERRIDE

VOLTAGECURRENT

FLYING CABLE, IP 67

JUNCTION BOX WITH LED, IP 67


IIA, IIB (Side entry)

34

35

38

Corrosive Environment CO

IIC (Side entry)

36

37

39

Nuclear

63

64

NP

INTRINSICALLY SAFE IP 67
NOTE : voltage 24V DC only
E Ex ia (Side entry)

62

Standard Version 32105-6-2G+24V-DC-25


Special Version
32105-6-2R-B5-S2+220V DC-50Hz-52-H
Specifications are subject to change without notice.

Refer page no.14 for suggested application.

FLUID CONTROL SYSTEM

3/2 DIRECT ACTING REGULATING, NAMUR SOLENOID VALVE


2

TYPE PRESSURE TYPE PRESSURE TYPE PRESSURE TYPE PRESSURE


30136

0-10 bar
1

NC

DIMENSIONS

Actuator spring side vent port.

CONNECTIONS
TYPE

INLET OUTLET OUTLET EXHAUST EXHAUST

30136

4 *

FEATURES
Air or Power failure to return.
Unique 3 way design for locking.
Single Acting spring return Actuator in multiple position
required for modulating flow.
Solenoid can be pulsed directly or through PID Controller.

Suitable for air, Gases, water, oil, etc;


Accessories for mounting the Solenoid Valve on the Actuator
are provided.
Solenoid of any voltage rating/construction can be replaced at
customers end.
Special versions may be developed on request.

ORDERING CODE
VALVE CODE

TYPE SUFFIX
PRESSURE

30136

PORT CONNECTION

BODY &
INTERNAL

MANUAL
OVERRIDE

SEAL

kv
ORIFICE lpm@1bar
0 - 10

2.5

3.5

SIZE

BSP

NPT

1/4

2G

2R

BODY

CODE

Aluminium

Push & Turn


NIL

NBR
M0

EPDM

S1
S2

0-8

3.0

4.0

Brass

B2

VITON

0-6

3.5

5.0

SS304

B4

NEOPRENE S3

0-4

4.0

7.0

SS316

B5

SOLENOID CODE

VOLTAGE CURRENT

CONSTRUCTION

12

50Hz

24

60HZ

GENERAL PURPOSE / WEATHERPROOF

48

DC

TYPE
Flying Lead, IP 67

01

125

Terminal Box 3/4 ET, IP 67

15

220

Terminal Box 1/2NPT, IP 67

16

240

Terminal Box M20 x 1.5, IP 67

14

Plug in, Pg9, IP 67

25

Plug in, Pg9, IP 67 with LED

22

Need not be specified while ordering.

ORDERING EXAMPLE
Standard Version
Special Version

SPECIAL VERSION
NIL

Cable entry

CLASS H H

Ammonia

AM

CLASS C C

Intrinsically Safe

IS

Refinery

PC

52

Temp. Class T6

T6

57

Low Power

LW

FLYING CABLE, IP 67
50

IIC

INSULATION

3/4 ET NPT M20 x 1.5

TYPE

IIA, IIB

CLASS F

FLAMEPROOF (IP 67)

55

51
56

Corrosive Environment CO

JUNCTION BOX WITH LED, IP 67


IIA, IIB (Side entry)

34

35

38

IIC (Side entry)

36

37

39

63

64

Nuclear

NP

INTRINSICALLY SAFE IP 67
NOTE : voltage 24V DC only
E Ex ia (Side entry)

30136-3.0-2G+24V-DC-22
30136AM-3.0-2G-B5-S2+24V-DC-35-H

Specifications are subject to change without notice.

CODE

110

62

Refer page no.14 for suggested application.

FLUID CONTROL SYSTEM

3/3 DIRECT ACTING REGULATING, NAMUR SOLENOID VALVE


TYPE PRESSURE TYPE PRESSURE TYPE PRESSURE TYPE PRESSURE
4

30131

0-10 bar
NC

A
3
1

DIMENSIONS

Actuator spring side vent port.

CONNECTIONS
TYPE

INLET OUTLET OUTLET EXHAUST

30131

4 *

FEATURES
Air or Power failure to retain position.
Unique 3 way design for locking.
Ideally suited for Single Acting spring return Actuator in
multiple position required for modulating flow.
Exhaust purged to spring chamber.
Special versions may be developed on request
.ORDERING CODE

Solenoid can be pulsed directly or through PID Controller.


Suitable for air, Gases, water, etc;
Accessories for mounting the Solenoid Valve on the Actuator
are provided.
Solenoid of any voltage rating/construction can be replaced at
customers end.

VALVE CODE

TYPE SUFFIX
PRESSURE

30131

PORT CONNECTION

BODY &
INTERNAL

MANUAL
OVERRIDE

SEAL

kv
ORIFICE lpm@1bar
0 - 10

3.0

4.0

0-8

3.5

4.5

SIZE

BSP

NPT

1/4

2G

2R

BODY

CODE

Aluminium

Push & Turn


NIL

NBR
EPDM

S1

Brass

B2

VITON

S2

SS304

B4

NEOPRENE S3

SS316

B5

M0

SOLENOID CODE

VOLTAGE CURRENT

CONSTRUCTION

12

50Hz

24

60HZ

GENERAL PURPOSE / WEATHERPROOF

48

DC

TYPE

CODE

SPECIAL VERSION
NIL

Cable entry

CLASS H H

Ammonia

AM

CLASS C C

Intrinsically Safe

IS

Refinery

PC

52

Temp. Class T6

T6

57

Low Power

LW

110
125

Terminal Box 3/4 ET, IP 67

15

220

Terminal Box 1/2NPT, IP 67

16

IIA, IIB

50

51

240

Terminal Box M20 x 1.5, IP 67

14

IIC

55

56

Plug in, Pg9, IP 67

25

Plug in, Pg9, IP 67 with LED

22

Standard Version
Special Version

INSULATION

3/4 ET NPT M20 x 1.5

TYPE

01

ORDERING EXAMPLE

CLASS F

FLAMEPROOF (IP 67)

Flying Lead, IP 67

Need not be specified while ordering.

FLYING CABLE, IP 67

Corrosive Environment CO

JUNCTION BOX WITH LED, IP 67


IIA, IIB (Side entry)

34

35

38

IIC (Side entry)

36

37

39

63

64

Nuclear

NP

INTRINSICALLY SAFE IP 67
NOTE : voltage 24V DC only
E Ex ia (Side entry)

62

30131-3.0-2G+24V-DC-22
30131CO-3.0-2G-B5-S2+24V-DC-38-H

Specifications are subject to change without notice.

Refer page no.14 for suggested application.

FLUID CONTROL SYSTEM

3/2 DIRECT ACTING ON / OFF / REGULATING, NAMUR SOLENOID VALVE


TYPE PRESSURE TYPE PRESSURE TYPE PRESSURE TYPE PRESSURE

30138

0-10 bar
NC

B
3

DIMENSIONS

Actuator spring side vent port.

CONNECTIONS
TYPE

INLET OUTLET

30138

OUTLET

EXHAUST

4 *

FEATURES
Most suited for stopping spring return actuator to mid position
set through limit switch.
Air or Power failure to return.
Direct Acting low cost.
Solenoid of any voltage rating/construction can be replaced at
customers end.
Special versions may be developed on request.

Solenoid can be operated directly or through PID Controller.


Manual Override push to operate & turn to lock is standard.
Suitable for air, gases, water, etc;
Accessories for mounting the Solenoid Valve on the Actuator
are provided.
Exhaust purged to spring chamber.

ORDERING CODE
VALVE CODE

TYPE SUFFIX
PRESSURE

30138

PORT CONNECTION

BODY &
INTERNAL

MANUAL
OVERRIDE

SEAL

kv
ORIFICE lpm@1bar
0 - 10

2.5

3.5

0-8

3.0

4.0

SIZE

BSP

1/4

2G

BODY

NPT

Aluminium

2R

SOLENOID CODE

VOLTAGE CURRENT

60HZ

GENERAL PURPOSE / WEATHERPROOF

48

DC

TYPE

CODE

110

Flying Lead, IP 67

01

125

Terminal Box 3/4 ET, IP 67

15

220

Terminal Box 1/2NPT, IP 67

16

240

Terminal Box M20 x 1.5, IP 67

14

Plug in, Pg9, IP 67

25

Plug in, Pg9, IP 67 with LED

22

Need not be specified while ordering.

ORDERING EXAMPLE

EPDM

S1

VITON

S2

SS304

B4

NEOPRENE S3

SS316

B5

FLAMEPROOF (IP 67)

INSULATION

SPECIAL VERSION
NIL

CLASS F

Cable entry

CLASS H H

Ammonia

AM

CLASS C C

Intrinsically Safe

IS

Refinery

PC

52

Temp. Class T6

T6

57

Low Power

LW

FLYING CABLE, IP 67
50

IIC

3/4 ET NPT M20 x 1.5

TYPE

IIA, IIB

M0

55

51
56

Corrosive Environment CO

JUNCTION BOX WITH LED, IP 67


IIA, IIB (Side entry)

34

35

38

IIC (Side entry)

36

37

39

63

64

Nuclear

NP

INTRINSICALLY SAFE IP 67
NOTE : voltage 24V DC only
E Ex ia (Side entry)

62

30138-2.5+220V-50Hz-16
30138PC-2.5-B2-S2+110V-50Hz-35-H

Specifications are subject to change without notice.

Nil

NBR

B2

CONSTRUCTION

50Hz

24

Push & Turn

Brass

12

Standard Version
Special Version

CODE

Refer page no.14 for suggested application.

FLUID CONTROL SYSTEM

5/3 DIRECT ACTING ON / OFF / REGULATING, NAMUR SOLENOID VALVE


TYPE PRESSURE TYPE PRESSURE TYPE PRESSURE TYPE PRESSURE
2

50401

0-10 bar

50402

0-10 bar

NC

B
3

DIMENSIONS

CONNECTIONS
TYPE

INLET OUTLET

50401, 50402

OUTLET

EXHAUST

EXHAUST

FEATURES
Air or Power failure to retain position.
Direct Acting, low cost alternative to 5 port valve.
Most economical, best suited for Double Acting Rotary
Actuator connected to either Ball Valve or Plug Valve on
ON / OFF & control duty.
Solenoid can be operated directly or through PID Controller.

Manual Override push to operate & turn to lock is standard.


Suitable for air, gases, water, oil, etc;
Accessories for mounting the Solenoid Valve on the Actuator
are provided.
Solenoid of any voltage rating/construction can be replaced at
customers end.
Special version may be developed on request.

ORDERING CODE
VALVE CODE

TYPE SUFFIX
PRESSURE

50401
ORIFICE

0 - 10

50402

kv
kv
ORIFICE
lpm@1bar
lpm@1bar

1.8

1.8

3.0

4.0

PORT CONNECTION

BODY &
INTERNAL

MANUAL
OVERRIDE

SEAL

SIZE

BSP

NPT

1/4

2G

2R

BODY

CODE

Aluminium

Push & Turn


Nil

NBR
M0

EPDM

S1
S2

0-8

2.2

2.5

3.5

5.0

Brass

B2

VITON

0-6

2.5

3.5

4.0

7.0

SS304

B4

NEOPRENE S3

0-4

3.0

4.0

4.0

7.0

SS316

B5

SOLENOID CODE

VOLTAGE CURRENT

a
CONSTRUCTION

12

50Hz

24

60HZ

GENERAL PURPOSE / WEATHERPROOF

48

DC

TYPE

CODE

FLAMEPROOF (IP 67)

CLASS H H

Ammonia

AM

Intrinsically Safe

IS

Refinery

PC

52

Temp. Class T6

T6

57

Low Power

LW

125

Terminal Box 3/4 ET, IP 67

15

220

Terminal Box 1/2NPT, IP 67

16

IIA, IIB

50

51

240

Terminal Box M20 x 1.5, IP 67

14

IIC

55

56

Plug in, Pg9, IP 67

25

Plug in, Pg9, IP 67 with LED

22

FLYING CABLE, IP 67

Corrosive Environment CO

JUNCTION BOX WITH LED, IP 67


IIA, IIB (Side entry)

34

35

38

IIC (Side entry)

36

37

39

63

64

Nuclear

NP

INTRINSICALLY SAFE IP 67
NOTE : voltage 24V DC only

E Ex ia (Side entry)
50401-2.2+220V-50Hz-15
50401-2.2-B2-S2+110V-50Hz-35-H

Specifications are subject to change without notice.

SPECIAL VERSION
NIL

CLASS C C

01

Standard Version
Special Version

INSULATION
CLASS F

Cable entry

Flying Lead, IP 67

ORDERING EXAMPLE

3/4 ET NPT M20 x 1.5

TYPE

110

Need not be specified while ordering.

62

Refer page no.15 for suggested application.

FLUID CONTROL SYSTEM

5/2 INTERNAL PILOT OPERATED, POPPET TYPE, NAMUR, SOLENOID VALVE


TYPE PRESSURE TYPE PRESSURE TYPE PRESSURE TYPE PRESSURE
2 4

51424

2-10 bar

52408

0-10 bar

BIFUNCTIONAL
3

DIMENSIONS

Pilot pressure minimum 3 bar


or > media pressure, whichever
is higher.

CONNECTIONS
TYPE

Photograph with flameproof Solenoid


FEATURES

INLET OUTLET EXHAUST

51424

52408

Bifunctional Version.
High Flow Rate, kv = 12 (lpm@1bar), Fast Response Time.
Minimum operating pressure required.
Suitable for air, gases, water etc.
Ideally suited for Double Acting Actuator on ON / OFF &
control Duty.
Special versions may be developed on request.

PILOT
INLET

PILOT
VENT

PILOT

INTERNAL

EXTERNAL

Poppet Design.
Accessories for mounting the Solenoid Valve on the Actuator
are provided.
Solenoid of any voltage rating/construction can be replaced at
customers end.
External pilot air operated available.

ORDERING CODE
VALVE CODE

ORIFICE
6.0

PORT CONNECTION

TYPE SUFFIX

SIZE
1/4"

BSP
2G

BODY & INTERNAL


BODY
Aluminium
Brass
SS304
SS316

NPT
2R

SOLENOID CODE

CODE

50Hz

24

60HZ

GENERAL PURPOSE / WEATHERPROOF

48

DC

TYPE

INSULATION

SPECIAL VERSION
NIL

Cable entry

CLASS H H

Manual Reset

MR

CLASS C C

Ammonia

AM

Intrinsically Safe

IS

52

Refinery

PC

57

Temp. Class T6

T6

Low Power

LW

125

Terminal Box 3/4 ET, IP 67

15

220

Terminal Box 1/2NPT, IP 67

16

IIA, IIB

50

51

240

Terminal Box M20 x 1.5, IP 67

14

IIC

55

56

Plug in, Pg9, IP 67

25

Plug in, Pg9, IP 67 with LED

22

Need not be specified while ordering.

S1
S2
S3

3/4 ET NPT M20 x 1.5

TYPE

01

ORDERING EXAMPLE

NBR
EPDM
VITON
NEOPRENE

CLASS F

FLAMEPROOF (IP 67)

CODE

MO

B2
B4
B5

Flying Lead, IP 67

110

Push & Turn


NIL

CONSTRUCTION

12

SEAL

MANUAL OVERRIDE

VOLTAGE CURRENT

FLYING CABLE, IP 67

JUNCTION BOX WITH LED, IP 67


IIA, IIB (Side entry)

34

35

38

Corrosive Environment CO

IIC (Side entry)

36

37

39

Nuclear

63

64

NP

INTRINSICALLY SAFE IP 67
NOTE : voltage 24V DC only
E Ex ia (Side entry)

62

Standard Version 51424-6-2G+110V-50Hz-01


Special Version 51424T6-6-2G-B5-S2+24V-DC-37-H
Specifications are subject to change without notice.

10

Refer page no.15 for suggested application.

FLUID CONTROL SYSTEM

5/2 INTERNAL PILOT OPERATED,POPPET TYPE, NAMUR,


DOUBLE SOLENOID VALVE
TYPE PRESSURE TYPE PRESSURE TYPE PRESSURE TYPE PRESSURE
2 4

57412

2-10 bar
BIFUNCTIONAL
3

5
1

DIMENSIONS

CONNECTIONS
TYPE

INLET OUTLET EXHAUST

57412

PILOT
VENT

FEATURES
Bifunctional Version.
High Flow Rate, kv = 12(lpm@1bar), Fast Response Time.
Minimum operating pressure required.
Suitable for air, gases, water etc;
Ideally suited for Double Acting Actuators on ON-OFF
& control duty.

Special versions may be developed on request.


Poppet Design.
Accessories for mounting the Solenoid Valve on the Actuator
are provided.
Solenoid of any voltage rating/construction can be replaced
at customers end.
External pilot air operated available.

ORDERING CODE
VALVE CODE

ORIFICE
6.0

PORT CONNECTION

TYPE SUFFIX

SIZE
1/4"

BSP
2G

BODY & INTERNAL


BODY
Aluminium
Brass
SS304
SS316

NPT
2R

SOLENOID CODE

50Hz

24

60HZ

GENERAL PURPOSE / WEATHERPROOF

48

DC

TYPE

CODE

110

Flying Lead, IP 67

01

125

Terminal Box 3/4 ET, IP 67

15

220

Terminal Box 1/2NPT, IP 67

16

Push & Turn


NIL

240

Terminal Box M20 x 1.5, IP 67

14

Plug in, Pg9, IP 67

25

Plug in, Pg9, IP 67 with LED

22

Need not be specified while ordering.

ORDERING EXAMPLE

NBR
EPDM
VITON
NEOPRENE

S1
S2
S3

INSULATION
CLASS F

SPECIAL VERSION
NIL

Cable entry

CLASS H H

Ammonia

AM

3/4 ET NPT M20 x 1.5

CLASS C C

Intrinsically Safe

IS

Refinery

PC

52

Temp. Class T6

T6

57

Low Power

LW

TYPE

FLYING CABLE, IP 67
50

IIC

MO

B2
B4
B5

FLAMEPROOF (IP 67)

IIA, IIB

SEAL

MANUAL OVERRIDE

CONSTRUCTION

12

Standard Version
Special Version

CODE

VOLTAGE CURRENT

55

51
56

Corrosive Environment CO

JUNCTION BOX WITH LED, IP 67


IIA, IIB (Side entry)

34

35

38

IIC (Side entry)

36

37

39

63

64

Nuclear

NP

INTRINSICALLY SAFE IP 67
NOTE : voltage 24V DC only
E Ex ia (Side entry)

62

57412-6-2G+110V-50Hz-01
57412-6-2G-B5+110V-50Hz-37-H

Specifications are subject to change without notice.

Refer page no.15 for suggested application.

11

FLUID CONTROL SYSTEM

5/2 - 3/2 CONVERTIBLE, NAMUR SOLENOID VALVE


TYPE

PRESSURE

TYPE

PRESSURE

TYPE

PRESSURE
2

VAD213-NC 3-10 bar


BIFUNCTIONAL
3

DIMENSIONS
125

10
O5.5

3/2 VERSION
32

7
5

Actuator spring side vent port.

40

Turn Disk slot to 5

24

5/2 VERSION

CONNECTIONS

Turn Disk slot to 4

INLET

OUTLET

OUTLET

4*

EXHAUST EXHAUST

PILOT VENT

FEATURES
High flow NW 5.3, Kv=10lpm@1bar.
Long lasting PTFE Seals.
Temperature - 20 c to70 c.
Lubrication is not necessary.
Media :- Dry or lubricated air filtered to 50 .m
Spool Design.
Easily converted to 3/2.
Special version s may be developed on request.

Manual Override with lock facility.


Double Solenoid version available.
IP 67 Solenoid, Explosion proof version Solenoid on request.
Corrosion resistance Anodized Aluminium.
All voltage ratings available.
Accessories for mounting the Solenoid Valve on the Actuator
are provided.
Exhaust purged to spring chamber can be provided on request.

ORDERING CODE
VALVE CODE

ORIFICE
5.3

PORT CONNECTION

TYPE SUFFIX

SIZE
1/4"

BSP
2G

c
BODY & INTERNAL
BODY
Aluminium
Brass
SS304
SS316

NPT
2R

d
CODE

SEAL

MANUAL OVERRIDE
Lockable
NIL

MO

B2
B4
B5

NBR+P.T.F.E.
EPDM+P.T.F.E.
VITON+P.T.F.E.
NEOPRENE+
P.T.F.E.

S1
S2
S3

SOLENOID CODE

VOLTAGECURRENT
12

50Hz

24

60HZ

GENERAL PURPOSE / WEATHERPROOF FLAMEPROOF (IP 67)

48

DC

TYPE

110

CONSTRUCTION
CODE TYPE

Cable entry
Pg9

Plug in, Pg9, IP 67

125

INSULATION

SPECIAL VERSION
NIL

CLASS F

Intrinsically Safe

IS

Refinery

PC

Corrosive Environment CO

FLYING CABLE, IP 67

220

IIA, IIB

240

INTRINSICALLY SAFE IP 67

50

NOTE : voltage 24V DC only

Need not be specified while ordering.

E Ex ia

62

ORDERING EXAMPLE
Standard Version
Special Version

VAD213-NC-5.3-2G+24V-DC
VAD213-NC-5.3-2G-B2-S2+24V-DC

Specifications are subject to change without notice.

12

Refer page no.15 for suggested application.

FLUID CONTROL SYSTEM

5/2 - 3/2 CONVERTIBLE, WITH INTEGRAL FLOW CONTROL


NAMUR SOLENOID VALVE
TYPE

PRESSURE

TYPE PRESSURE TYPE PRESSURE


4

VAD213-NC-FC 3-10 bar


BIFUNCTIONAL
5

3
1

DIMENSIONS

125

10
O5.5

3/2 VERSION
32

7
5

Actuator spring side vent port.

40

Turn Disk slot to 5

24

5/2 VERSION

CONNECTIONS

Turn Disk slot to 4

INLET

OUTLET

OUTLET

4 *

EXHAUST EXHAUST

PILOT VENT

FEATURES
High flow NW 5.3, Kv=10lpm@1bar.
Long lasting PTFE Seals.
Temperature - 20 c to70 c.
Lubrication is not necessary.
Media :- Dry or lubricated air filtered to 50
Spool Design.
Easily converted to 3/2.
All voltage ratings available.

Manual Override with lock facility.


Double Solenoid version available.
IP 67 Solenoid, Explosion proof version Solenoid on request.
Corrosion resistance Anodized Aluminium.
Exhaust purged to spring chamber can be provided on request.
Accessories for mounting the Solenoid Valve on the Actuator are provided.
Highly sensitive flow regulation, for achieving very slow to full speed operation
of the Actuator.

ORDERING CODE
VALVE CODE

ORIFICE
5.3

PORT CONNECTION

TYPE SUFFIX

SIZE
1/4"

BSP
2G

c
BODY & INTERNAL
BODY
Aluminium
Brass
SS304
SS316

NPT
2R

d
CODE

SEAL

MANUAL OVERRIDE
Lockable
NIL

MO

B2
B4
B5

NBR+P.T.F.E.
EPDM+P.T.F.E.
VITON+P.T.F.E.
NEOPRENE+
P.T.F.E.

S1
S2
S3

SOLENOID CODE

VOLTAGE CURRENT

CONSTRUCTION

12

50Hz

24

60HZ

GENERAL PURPOSE / WEATHERPROOF FLAMEPROOF (IP 67)

48

DC

TYPE

CODE TYPE

Cable entry
Pg9

Plug in, Pg9, IP 67

110

FLYING CABLE, IP 67

220

IIA, IIB

240

INTRINSICALLY SAFE IP 67

ORDERING EXAMPLE
Standard Version
Special Version

INSULATION

SPECIAL VERSION
NIL

CLASS F

Intrinsically Safe

IS

Refinery

PC

Corrosive Environment CO

125

Need not be specified while ordering.

50

NOTE : voltage 24V DC only


E Ex ia

62

VAD213-NC-FC-5.3-2G+220V-50Hz
VAD213-NC-FC-5.3-2G-B4+24V-DC

Specifications are subject to change without notice.

Refer page no.15 for suggested application.

13

FLUID CONTROL SYSTEM

i
i

APPLICATION

The Solenoid Valve can be used for other applications also.


To ensure correct orientation of the Solenoid Valve, fix M5 grub screw on the Actuator, projecting 2~3 mm,
at one of the M5 hole, other than the one used for mounting the Solenoid Valve.

2
A

A B ACTION
OFF OFF Return to spring position.
ON ON Open
OFF ON Can stop to intermediate

Type : 30136

Type : 30106, 30107

1
3

5
1

Inching application.
Air & Power failure to close.

ON - OFF & control duty for Spring Return Actuator


Air & Power failure to close.

2
3

A
3

Inching application.
Air & Power failure to stayout.

ON - OFF service for Spring Return Actuator.


Air & Power failure to close.

Type : 30318, 30319

Exhaust Purged to spring chamber.

Type : 30138
PARTIAL OPEN

FULL OPEN

A
1

COMMON

B
3
1
ON - OFF & control duty for Spring Return Actuator
Air & Power failure to close.
Exhaust purged to spring chamber.

Type : 31113

3
Scheme for 3 position Actuator in sequence full open - part open - close
Air & Power failure to close.
Exhaust Purged to spring chamber.

Type : 32105

ON - OFF & control duty for Spring Return Actuator


Air & Power failure to close.
Exhaust Purged to spring chamber.
Specifications are subject to change without notice.

14

A B ACTION
OFF OFF Return to spring position.
ON ANYOpen
OFF ON Can stop to intermediate

A B ACTION
ON OFF Open
OFF OFF Can stop to intermediate
position

Type : 30131

Type : 30120, 30121

ON - OFF & control duty for Spring Return Actuator


Exhaust Purged to spring chamber.
Air & Power failure to close.

FLUID CONTROL SYSTEM

i
i

APPLICATION

The Solenoid Valve can be used for other applications also.


To ensure correct orientation of the Solenoid Valve, fix M5 grub screw on the Actuator, projecting 2~3 mm,
at one of the M5 hole, other than the one used for mounting the Solenoid Valve.

A B ACTION
OFF OFF Can stop to intermediate
position.
ON OFF Open

Type : 50401

B
3

Type : 57412

5
1

Inching application for Double Acting Actuator. (Typically for Terminal Automation)
Suitable for Ball valve & plug valve only. (Unsuitable for Butterfly Valve & Dampers)
Air & Power failure to stayput.

Type : 51424

ON - OFF duty for Double Acting Actuator


Power failure to stayout.

Type : 52408

5
3

ON - OFF duty for Double Acting Actuator


Power failure to close. Air failure to stayput.

Volume Tank
NRV

ON - OFF & control duty for Double Acting Actuator


Air & Power failure to close.

Type : VAD213 - NC

3 1 5

5/2 Mode (Turn Disk slot to 4)

3/2 Mode (Turn Disk slot to 5)

Type : VAD213-NC-FC

5
1

1
5/2 Mode (Turn Disk slot to 4)

3/2 Mode (Turn Disk slot to 5)

Specifications are subject to change without notice.

15

ROTEX
MANUFACTURERS & ENGINEERS PVT. LTD
Manpada Road, Dombivli (E)-421204
Maharashtra, INDIA
Ph. : +91 251 2871033 / 2871390 / 2871196 /
2871989 / 2870890 / 2870663
Fax : +91 251 871191 / 870864
E-mail : rotexdbl@rotexindia.com

ROTEX AUTOMATION LIMITED


UNIT 1
987/11, G.I.D.C. Makarpura,
Vadodara-390010, Gujarat
Ph. : +91 265 2638136 / 2638795 / 46
Fax : +91 265 2638130
E-mail : rotexbrd@rotexindia.com

www.rotexindia.com

UNIT 2
C-1 B/1501, 4 & 5, G.I.D.C.
Vithal Udyongnagar, Gujarat-388121
Ph. : +91 2692 236224 / 236292 /
236399
Fax : +91 2692 236442
E-mail : rotxvun@rotexindia.com

S-ar putea să vă placă și