Selection and ordering data

3NP4 standard series

3NP4 standard series Accessories


Accessories

Basic versions
For surface mounting and switchboard install.

Connection in mm2

160 A1)
160 A

Size 000
Size 00

250 A
400 A
630 A

Size
Size
Size

1.5 50
up to 2 x 70 (M8)
2.5 70
up to 150 (M10)
up to 240 (M12)
up to 2 x 240 (M12)

1
2
3

SIGUT terminal
Flat pad connection
SIGUT terminal
Flat pad connection
Flat pad connection
Flat pad connection

For 40 mm busbars2)
160 A1)

160 A

Size 000

Size 00

Flat pad connection

SIGUT terminal

250 A

Size

Flat pad connection

For 60 mm busbars
160 A1)

160 A

Size 000

Size 00

400 A
630 A

Size
Size
Size

1
2
3

With fuse monitoring

1.5 50
Connection, top
Connection, bottom
up to 2 x 70 (M8)
Connection, top
Connection, bottom
2.5 70
Connection, top
Connection, bottom
up to 150 (M10)
top or bottom3)

3NP4015 1CK01
3NP4015 1CJ01
3NP4075 1CE01
3NP4075 1CF01
3NP4075 1CK01
3NP4075 1CJ01
3NP4275 1CG01

Connection in mm2
SIGUT terminal

Flat pad connection

SIGUT terminal

250 A

3NP4010 0CH10
3NP4070 0CA01
3NP4070 0CH01
3NP4270 0CA01
3NP4370 0CA10
3NP4470 0CA01

Connection in mm2
SIGUT terminal

Flat pad connection


Flat pad connection
Flat pad connection

By simply snapping onto the busbars from the top,


the disconnectors can also be mounted onto T or
double T profiles as well as onto Power-Line systems
from the Rittal company, without the horizontal parts
of the busbars preventing this.

1.5 50
Connection, top
Connection, bottom

3NP4016 1CK01
3NP4016 1CJ01

up to 2 x 70 (M8)
Connection, top
Connection, bottom

3NP4076 1CE01
3NP4076 1CF01

2.5 70
Connection, top
Connection, bottom

3NP4076 1CK01
3NP4076 1CJ01

up to 150 (M10)
top or bottom3)

3NP4276 1CG01

up to 240 (M12)
top or bottom3)

3NP4376 1CG01

up to 2 x 240 (M12)
top or bottom3)

3NP4476 1CG01

400 690 V AC, 220 V DC

 all of the versions specified above (except size 000) are also available with mounted fuse
monitoring; Order No. supplement: 3NP4.F.01
1) 125 and 160 A only with special, 21-mm-wide fuses 3NY1822 and 3NY1824, refer to Accessories
2) Adapter depth, 28 mm; for disconnectors with deeper adapters (49 mm), refer to Catalog NSK, Section 12
3) Connection modules can be replaced, refer to the Instruction Manual

for 3NP401
Size 000

for 3NP407
Size 00

for 3NP42
Size 1

for 3NP43
Size 2

Connection terminals
(1 set = 3 units) connection:

integrated

integrated

3NY7120
70 150 mm2

3NY7130
3NY7140
120 240 mm2 150 300 mm2

Cable lug cover


(1 set = 3 units) safe from
finger touch cover of the flat
pad connection acc. to VBG4

not required

3NY7101

3NY7121

3NY7131

Auxiliary contact,
1 changeover contact
normal version
electronics-compatible
Quick retaining plate
to mount the disconnectors
between two mounting rails
(125 mm clearance)

3NY3035
3NY3030

3NY3035
3NY3030

3NY3035
3NY3030

3NY3035
3NY3030

3NY1995

3NY1995

3NY7322

3-phase busbars
for 2 disconnectors
for 3 disconnectors
for 4 disconnectors
connecting buses
for > 4 disconnectors
cap for empty location (20x units):
Incoming supply terminal
(1 set = 3 units) for conductors e/m: up to 95 mm2
finely stranded with end
sleeves: up to 70 mm2

Masking frames
for mounting in general
distribution systems
for disconnectors with
SIGUT terminal
for disconnectors with
flat pad connection
Dimensions (H x W):
Overreach protection
(10 units)

The circuit-breaker is connected in parallel to the


three main disconnector phases, and is tripped as
soon as at least one of three fuses blows. The voltage
is tapped at the handle lugs of the fuses which means
that only fuses with live grip lugs can be used.

not required
break-off

3NY7381
not required

3NY7381
not required

not possible
not required

3NY7102

3NY7102

3NY7105

3NY1237
3NY1238
3NY1438

3NY1263
3NY1265

3NY1236

integrated

integrated

3NY7482

3NY7482

3NY7482

3NY1251

3NY7200

215 x 130

3NY7201
215 x 130

3NY7220
375 x 220

3NY7230
375 x 245

3NY7240
375 x 290

integrated

integrated

3NY7481

3NY7481

3NY7481

 for spare parts, refer to Catalog NSK, Section 12


 for masking frames and mounting sets for 8HP molded-plastic distribution systems, refer to Catalog
E20001-8ZX1012-OHP54-5AB1

This button prevents the shock protection from


being inserted as long as the latching mechanism
hasnt correctly latched into place.

Allaround safety
With the cable lug covers correctly
mounted, the enclosed disconnectors offer a high IP
30 degree of protection, even after a voltage test
using the 6 test holes in the withdrawable fuse carrier. The versions with SIGUT terminals are completely
safe from finger touch without any additional covers.
The large clear inspection window allows the type
and the operating statuses of the fuse links to be
quickly and reliably identified. Overreach and reacharound touch protection is already integrated into
the withdrawable fuse carrier up to 160 A; from
Size 1 shock protection is available as accessory.
At home on all busbars
All 3NP4 sizes are available for 40 mm or 60 mm
busbar center clearance. Busbars can either be 5 or
10 mm wide. For 10 mm busbars, for sizes 000 and
00, two lugs must be broken off at the three rear
busbar clamps. Busbar compensation is available
as accessory for mounting sizes 1 and 2 onto 5 mm
busbars (size 3 disconnectors cannot only be
snapped onto 5 mm busbars).

Quickly mounted
All of these features reduce valuable mounting
and installation time. It also means that the correct
tightening torque of the screws doesnt have to be
checked and adjusted. The mounting rail latching
mechanisms, integrated into the basic size 000 and
00 devices, also provide a clear financial benefit,
especially, where up to 160 A disconnectors are used
in larger unit quantities: additional screws, hooks,
intermediate plates or a second mounting rail are
not required.
Smart accessories for every
application
The auxiliary contacts, which fit all sizes, can be
subsequently retrofitted without taking up any
extra space.
The three-way terminal makes it easy to connect
up to 3 cables (e. g. for capacitor protection).
Several disconnectors can be fed in parallel using
the 3-phase busbars, connecting buses and feeder
terminals up to 225 A. Numerous masking frames
and mounting sets for SIKUS distribution boards or
the 8HP distribution system guarantee simple engineering and fast mounting and installation.

3NP Fuse Switch Disconnector


the Optimum Handle on Every Application

1NO/1NC signal outputs are used as standard. For


size 00, they are brought out to a connector socket
at the front, and for sizes 1 to 3, as double AMP flat
connector at the shock protection in the lower section
of the disconnector.
Either pre-assembled 1- or 3-m cables with strain
relief can be used as connecting cable for size 00.
These can then be easily inserted at the fuse monitoring using the mounted connectors. There are also
connector mounting sets for crimping (short-circuit
proof) cables.

3NP4 quickly mounted onto all busbars

Fuse links, size 000


21 mm wide, Duty class gL/gC
400 V/125 A
3NY1822
400 V/160 A
3NY1824
Sealing pin
can be retrofitted
(1 pkg. = 10 units)

can frequently occur, e. g. in line supplies with AC


drive converters and inverters.

Intelligent latching mechanism


This automatically adapts itself to busbar widths
between 5 and 30 mm, and it reliably latches into
place. This eliminates numerous versions and
complicated adjustments before mounting. There
is a small red button inside the switch, which,
especially from size 1, ensures that the disconnector
is really mounted onto the busbar to its endstop.

3NY7141

3NY3035
3NY3030

Busbar width compensation


only for 5 mm busbars
not required
for 10 mm busbars
break-off
Three-way terminal
(1 set = 3 units) to connect
3 x 2.5 16 mm2 (e/m) or
3 x 2.5 10 mm2 (finely
stranded with end sleeves)
for mounting onto a
SIGUT terminal
for mounting onto a
flat pad connection

for 3NP44
Size 3

Fuse monitoring for 3NP4

From size NH00 onwards, all of the 3NP4 versions are


also available with fuse monitoring. This is realized
using 3RV SIRIUS circuit-breakers which are mounted
at the front in the center of the fuse carrier.

Flat connectors are always used for sizes 13.

The disconnector can then be fed as required from


either the top or the bottom, whereby voltages up to
690 V AC/220 V DC are possible. Furthermore, this
type of fuse monitoring is completely insensitive to
EMC disturbances and harmonics. These disturbances

The function of the 3RV can be tested at any time


using the test button provided.

Technical data
Type
Rated operational voltage Ue

3NP401
AC 50/60 Hz V
DC V

3NP40 7

3NP42

3NP43

3NP44

690
690
220 (3 phases in series)
440 (2 phases in series)
with mounted fuse monitoring upt to 220 V DC max.

Rated conditional short-circuit current with fuses


(for fast closing)
With fuse links
rated current
Size/A
For 400 V AC (690 V)
kA (RMS value)
Permissible fuse cut-off current
kA (peak value)

000/100 (35) 00/160


50 (50)
50
11 (5)
15

1/250
50
25

2/400
50
35

3/630
50
55

Short-circuit strength with fuse


(with the disconnector closed)
With fuse links
rated current
Size/A
Up to 690 V
kA (RMS value)
Permissible fuse cut-off current
kA (peak value)

000/100
100
15

00/160
50
15

1/250
50
25

2/400
50
35

3/630
50
55

Rated operational current and switching capacity


(supply from either the top or bottom)
For 400 V AC, with fuse links or isolating links
Size
Rated breaking current Ic (cos p = 0.35) A (RMS value)
Rated operating current Ie for AC-21B, AC-22B
A
AC-23B
A

000
800
160
100

00
800
160
100

1
2,000
250
250

2
3,200
400
400

3
5,040
630
630

For 690 V AC, with fuse links or isolating links


Size
Rated breaking current Ic (cos p = 0.35) A (RMS value)
Rated operating current Ie for AC-21B
A
AC-22B
A
AC-23B
A

000
240
160
50
25

00
240
160
50
25

1
375
250

2
600
400

3
945
630

 for additional values, refer to Catalog NSK, Section 12 (e. g. capacitor and DC switching capacity, switching capacity
at 500 V AC, ...)

sentric

can also be safely handled, favorably-priced backup protection, simple selectivity calculations and absolute reliability, even when short-circuits occur. The fuse

3NP5 the rugged types for


the toughest applications

melts completely so that there is no residual risk as a result of contacts which


may have welded together. When the disconnector is in the open position,

Furthermore, 3NP5 have an extremely high AC-23


switching capacity. The switching gases which are
formed are deflected into the disconnector using a
sophisticated arc chamber design, instead of being
discharged upwards and to the side. This means
that operating personnel and plant sections and
components in the vicinity are reliably protected.

there is a visible isolating gap, which is often demanded, e. g. for maintenance


purposes. And the optional mounted fuse monitoring offers additional security
fuse switch disconnectors 3NP for the highest plant availability and safety.

Fuse monitoring:
To allow monitoring of the fuses in the disconnectors,
a permanently wired 3RV1 circuit-breaker is mounted
on the fuse carrier.

Fuses for your safety


3NP4 and 3NP5 switch disconnectors
ble to use other disconnectors available on the market. But the fast closing and arc deflection chambers
of the 3NP5 come through with flying colors. 3NP5
provides the highest degree of safety for operating
personnel and the plant, as main switch with high
switching frequency and good AC-23 characteristics,
e.g. for motor loads.
Both of these ranges are climate-proof and correspond to IEC 60 947-3 and VDE 0660, Part 107.
The fuses can be clearly identified through the large
clear inspection window.
Matching masking frames and complete, TSK-tested
mounting sets are available both for the moldedplastic 8HP distribution system as well as for the
various SIKUS distribution boards.
2 series in the range the optimum handle on
every application
The 3NP4 series (sizes NH000 to NH3) offer the
optimum solution for most applications. These range
from power distribution in residential and commercial buildings, through flexible distribution stations
up to power distribution systems in large industrial
plants.They are also admirably suited as main and
incoming feeder breakers in industry, for control
systems, as well as in motor feeders or as backup
protection for circuit-breakers. They have an integrated
lug for sealing which is integrated as standard.
This means that they can be used, without any
restrictions, in meter cabinets and incoming main
feeder boxes for buildings.
The rugged 3NP5 series (sizes NH00 to NH3)
provide reliable protection for all of the tougher
applications. This is especially true in mining, in the
steel industry, and also in the chemical industry,
where sulphur-laden, or aggressive ambient conditions or hazardous locations make it almost impossi-

The values for switching capacitors (e.g. for reactive


power compensation) were also tested (refer to
Catalog NSK, Section 12), and when used with SITOR
semiconductor or 3NE1 double-protection fuses,
3NP disconnectors can be used to protect soft starters,
AC drive converters and similar devices (tables with
tested device-fuse combinations are provided in the
NSK). Shock and vibration testing as well as special
earthquake tests guarantee that the 3NP can be used
in marine applications, nuclear power stations and
similar safety-critical plants.

high switching frequency for devices such as these.


The erosion electrodes additionally extend the lifetime of the main contacts. The lateral spring mechanism (= fast switching) eliminates any danger as
a result of incorrect operation, e.g. briefly actuating
the disconnector or switching which is too slow.

When the switch disconnector is in the ON position,


the circuit-braker poles are connected in parallel
with the fuses to be monitored. When the switch is
in the OFF position, the poles of the circuit-breaker
are dead.
The 3NP5 disconnector series (sizes NH00 to NH3)
for fixed installation can be quickly hung onto preinstalled mounting bolts. They can also be mounted
on the front of switchgear panels using the matching mounting sets or they can be mounted onto
60 mm busbar systems using 8US1 adapters.
The especially rugged design of this series (plastic
with a high resistance to heat, metal parts which can
be mechanically stressed), permits an unusually

The internal resistance of the circuit-breaker is so


high that it does not affect the protection given by
the monitored fuses.

Rated operational voltage Ue

Electronic fuse monitoring (EFM):


The electronic fuse monitoring system is also
mounted on the fuse carrier of the 3NP5. It works
whether or not a load is present. Fuse blowing can
be signalled to a switch control room by means of a
group indication (2NO contacts + 1NC contact).

For surface mounting and switchboard install. in mm

Auxiliary contacts

160 A

without
1NO/1NC
without
1NO/1NC
without
1NO/1NC
without
1NO/1NC
without
1NO/1NC
without
1NO/1NC

250 A

Size 00

Size 1

Flat pad connection

2.5 120

Clamp connection

2.5 50

Flat pad connection


Clamp connection

Short-circuit strength with fuse


(with the disconnector closed)
With fuse links
rated current
Size/A
For 500 V AC
kA (RMS value)
Permissible fuse cut-off current
kA (peak value)
Rated operating current and switching capacity
(supply from either the top or bottom)
For 400 V AC, with fuse links or isolating links
Size
Rated breaking current Ic (cos p = 0.35)
A (RMS value)
Rated operating current Ie for AC-21B up to AC-23B
A
For 690 V AC, with fuse links or isolating links
Size
Rated breaking current Ic (cos p = 0.35)
A (RMS value)
Rated operating current Ie for AC-21B, AC-22B
A
AC-23B
A

35 120

400 A

Size 2

Flat pad connection

6 240

630 A

Size 3

Flat pad connection

6 2 x 240

160 A

Size 00

in mm2

Auxiliary contacts

Flat pad connection


at the bottom

2.5 120

Clamp connection
at the bottom

2.5 50

without
1NO/1NC
without
1NO/1NC

3NP5065 1CF00
3NP5065 1CF10
3NP5065 1CG00
3NP5065 1CG10

400 690 V AC, 220 V DC

For surface mounting and switchboard install. in mm2

Auxiliary contacts2)

160 A

Size 00

Flat pad connection


Clamp connection

2.5 120
2.5 50

1NO/1NC
1NO/1NC

3NP5060 0EA86
3NP5060 0EB86

3NP54

250 A

Size 1

Flat pad connection


Clamp connection

6 150
35 120

1NO/1NC
1NO/1NC

3NP5260 0EA86
3NP5260 0EB86

690
440 (3 phases in series)
220 (2 phases in series with mounted fuse monitoring)

400 A
630 A

Size 2
Size 3

Flat pad connection


Flat pad connection

1NO/1NC
1NO/1NC

3NP5360 0EA86
3NP5460 0EA86

3NP52

3NP53

1)

Rated conditional short-circuit current with fuses


With fuse links
rated current
Size/A
For 500 V AC
kA (RMS value)
Permissible fuse cut-off current
kA (peak value)

6 150

3NP5060 0CA00
3NP5060 0CA00
3NP5060 0CB00
3NP5060 0CB10
3NP5260 0CA00
3NP5260 0CA10
3NP5260 0CB00
3NP5260 0CB10
3NP5360 0CA00
3NP5360 0CA10
3NP5460 0CA00
3NP5460 0CA10

With fuse monitoring

3NP50
50/60 Hz V AC
V DC

Basic versions

For 40 mm busbars1)

Technical data
Type

Selection and ordering data


3NP5 high end series

For 40 mm busbars
00/160
50
15

00/160
100
23

00
1,600
160
00
800
160
100

1/250 2/400 3/630


50
50
50
25
40
50

160 A

 for additional values refer to Catalog NSK, Section 12


(e. g. capacitor and DC switching capacity, switching capacity at 500 V AC, )

0
1,600
160
0
1,000
160
125

2
4,000
400
2
2,520
400
315

Flat pad connection


at the bottom
Clamp connection
at the bottom

Auxiliary contacts

2.5 120

1NO/1NC

3NP5065 1EF86

2.5 50

1NO/1NC

3NP5065 1EG86

400/500 V AC
2

1
2,500
250
1
1,600
250
200

3
5,040
630
3
3,200
630
400

2
4,000
400
2
2,520
400
315

2)

in mm

With electronic fuse monitoring

1/250 2/400 3/630


100
50
50
32
40
60

1
2,500
250
1
1,280
250
160

Size 00

6 240
6 2 x 240

For surface mounting and switchboard install. in mm

Auxiliary contacts

160 A

Size 00

Flat pad connection


Clamp connection

1NO/1NC
1NO/1NC

3NP5060 0HA13
3NP5060 0HB13

250 A
400 A
630 A

Size 1
Size 2
Size 3

Flat pad connection


Flat pad connection
Flat pad connection

1NO/1NC
1NO/1NC
1NO/1NC

3NP5260 0HA13
3NP5360 0HA13
3NP5460 0HA13

For 40 mm busbars1)
160 A

Size 00 at

Flat pad connection


the bottom

2.5 120
2.5 50
6 150
6 240
6 2 x 240
in mm2

Auxiliary contacts

2.5 120

1NO/1NC

3NP5065 1HF13

1) for mounting on 60 mm busbars, use devices for surface mounting and installation and 8US1 busbar adapters
2) optionally, 2 NO as signal outputs: Order No. 3NP5.E.26

3NP5 high end series Accessories


Accessories
for 3NP50
Size 00

for 3NP52
Size 1

for 3NP53
Size 2

for 3NP54
Size 3

Clamp connection
(1 set = 3 units)

3NY1903
2.5 50 mm2

3NY1907
35 120 mm2

Quick retaining plate


between 2 mounting
rails

3NY1995

Adapter
for mounting
on 60 mm
busbars

8US1291-4SB00

8US1210-4AG00

8US1210-4AG00

8US1210-4AG00

3NY1105
215 x 135

3NY1115
215 x 135

3NY1107
265 x 135

3NY1208
250 x 149

3NY1210
300 x 220

3NY1211
300 x 245

3NY1212
300 x 290

3NY1106
290 x 135

3NY1116
290 x 135

3NY1108

3NY1241

3NY1245

3NY1245

Auxiliary contacts
1NO/1NC
(= mounting set)

3NY3033

3NY3034

3NY3034

3NY3034

Sealing lug
can be retrofitted
(1 pkg. = 10 units)

3NY1940

Molded-plastic
masking frames
Dimensions (H x W):
for disconnectors
without/with auxiliary
contacts
Dimensions (H x W):
for disconnectors
with auxiliary contacts
Dimensions (H x W):
Masking frame
mounting set
Dimensions (H x W):
for mounting the disconnector in the front of
the switchgear panel
(masking frame and
mounting parts)
Cable lug cover
Masking frame (H x W)
for disconnectors without/
with auxiliary contacts
Masking frame (H x W)
for disconnectors
with auxiliary contacts
2 separate covers for
top/bottom
6 individual covers
(L = 120 mm)

 for spare parts, refer to Catalog NSK, Section 12


 for masking frames and mounting sets for 8HP molded-plastic distribution systems, refer to Catalog
8ZX1012-OHP54-5AB1
 for masking frames and mounting sets for SIKUS installation distribution panels, refer to Catalogs
I2.34 and 12.35

Subject to change without prior notice 08/02 | Bestell-Nr. EXXXXX-A190-PXXX | DISPO XXXXX | XXXXXXXXX PDWL.XX.X.XX WS 0802X.X | Printed in Germany

Fuses for overload and short-circuit protection means: high short-circuit currents

Siemens AG
Automation and Drives
Low Voltage Controls and Distribution
P. O. Box 32 40, D-91050 Erlangen
www.siemens.com/sentric

can also be safely handled, favorably-priced backup protection, simple selectivity calculations and absolute reliability, even when short-circuits occur. The fuse

3NP5 the rugged types for


the toughest applications

melts completely so that there is no residual risk as a result of contacts which


may have welded together. When the disconnector is in the open position,

Furthermore, 3NP5 have an extremely high AC-23


switching capacity. The switching gases which are
formed are deflected into the disconnector using a
sophisticated arc chamber design, instead of being
discharged upwards and to the side. This means
that operating personnel and plant sections and
components in the vicinity are reliably protected.

there is a visible isolating gap, which is often demanded, e. g. for maintenance


purposes. And the optional mounted fuse monitoring offers additional security
fuse switch disconnectors 3NP for the highest plant availability and safety.

Fuse monitoring:
To allow monitoring of the fuses in the disconnectors,
a permanently wired 3RV1 circuit-breaker is mounted
on the fuse carrier.

Fuses for your safety


3NP4 and 3NP5 switch disconnectors
ble to use other disconnectors available on the market. But the fast closing and arc deflection chambers
of the 3NP5 come through with flying colors. 3NP5
provides the highest degree of safety for operating
personnel and the plant, as main switch with high
switching frequency and good AC-23 characteristics,
e.g. for motor loads.
Both of these ranges are climate-proof and correspond to IEC 60 947-3 and VDE 0660, Part 107.
The fuses can be clearly identified through the large
clear inspection window.
Matching masking frames and complete, TSK-tested
mounting sets are available both for the moldedplastic 8HP distribution system as well as for the
various SIKUS distribution boards.
2 series in the range the optimum handle on
every application
The 3NP4 series (sizes NH000 to NH3) offer the
optimum solution for most applications. These range
from power distribution in residential and commercial buildings, through flexible distribution stations
up to power distribution systems in large industrial
plants.They are also admirably suited as main and
incoming feeder breakers in industry, for control
systems, as well as in motor feeders or as backup
protection for circuit-breakers. They have an integrated
lug for sealing which is integrated as standard.
This means that they can be used, without any
restrictions, in meter cabinets and incoming main
feeder boxes for buildings.
The rugged 3NP5 series (sizes NH00 to NH3)
provide reliable protection for all of the tougher
applications. This is especially true in mining, in the
steel industry, and also in the chemical industry,
where sulphur-laden, or aggressive ambient conditions or hazardous locations make it almost impossi-

The values for switching capacitors (e.g. for reactive


power compensation) were also tested (refer to
Catalog NSK, Section 12), and when used with SITOR
semiconductor or 3NE1 double-protection fuses,
3NP disconnectors can be used to protect soft starters,
AC drive converters and similar devices (tables with
tested device-fuse combinations are provided in the
NSK). Shock and vibration testing as well as special
earthquake tests guarantee that the 3NP can be used
in marine applications, nuclear power stations and
similar safety-critical plants.

high switching frequency for devices such as these.


The erosion electrodes additionally extend the lifetime of the main contacts. The lateral spring mechanism (= fast switching) eliminates any danger as
a result of incorrect operation, e.g. briefly actuating
the disconnector or switching which is too slow.

When the switch disconnector is in the ON position,


the circuit-braker poles are connected in parallel
with the fuses to be monitored. When the switch is
in the OFF position, the poles of the circuit-breaker
are dead.
The 3NP5 disconnector series (sizes NH00 to NH3)
for fixed installation can be quickly hung onto preinstalled mounting bolts. They can also be mounted
on the front of switchgear panels using the matching mounting sets or they can be mounted onto
60 mm busbar systems using 8US1 adapters.
The especially rugged design of this series (plastic
with a high resistance to heat, metal parts which can
be mechanically stressed), permits an unusually

The internal resistance of the circuit-breaker is so


high that it does not affect the protection given by
the monitored fuses.

Rated operational voltage Ue

Electronic fuse monitoring (EFM):


The electronic fuse monitoring system is also
mounted on the fuse carrier of the 3NP5. It works
whether or not a load is present. Fuse blowing can
be signalled to a switch control room by means of a
group indication (2NO contacts + 1NC contact).

For surface mounting and switchboard install. in mm

Auxiliary contacts

160 A

without
1NO/1NC
without
1NO/1NC
without
1NO/1NC
without
1NO/1NC
without
1NO/1NC
without
1NO/1NC

250 A

Size 00

Size 1

Flat pad connection

2.5 120

Clamp connection

2.5 50

Flat pad connection


Clamp connection

Short-circuit strength with fuse


(with the disconnector closed)
With fuse links
rated current
Size/A
For 500 V AC
kA (RMS value)
Permissible fuse cut-off current
kA (peak value)
Rated operating current and switching capacity
(supply from either the top or bottom)
For 400 V AC, with fuse links or isolating links
Size
Rated breaking current Ic (cos p = 0.35)
A (RMS value)
Rated operating current Ie for AC-21B up to AC-23B
A
For 690 V AC, with fuse links or isolating links
Size
Rated breaking current Ic (cos p = 0.35)
A (RMS value)
Rated operating current Ie for AC-21B, AC-22B
A
AC-23B
A

35 120

400 A

Size 2

Flat pad connection

6 240

630 A

Size 3

Flat pad connection

6 2 x 240

160 A

Size 00

in mm2

Auxiliary contacts

Flat pad connection


at the bottom

2.5 120

Clamp connection
at the bottom

2.5 50

without
1NO/1NC
without
1NO/1NC

3NP5065 1CF00
3NP5065 1CF10
3NP5065 1CG00
3NP5065 1CG10

400 690 V AC, 220 V DC

For surface mounting and switchboard install. in mm2

Auxiliary contacts2)

160 A

Size 00

Flat pad connection


Clamp connection

2.5 120
2.5 50

1NO/1NC
1NO/1NC

3NP5060 0EA86
3NP5060 0EB86

3NP54

250 A

Size 1

Flat pad connection


Clamp connection

6 150
35 120

1NO/1NC
1NO/1NC

3NP5260 0EA86
3NP5260 0EB86

690
440 (3 phases in series)
220 (2 phases in series with mounted fuse monitoring)

400 A
630 A

Size 2
Size 3

Flat pad connection


Flat pad connection

1NO/1NC
1NO/1NC

3NP5360 0EA86
3NP5460 0EA86

3NP52

3NP53

1)

Rated conditional short-circuit current with fuses


With fuse links
rated current
Size/A
For 500 V AC
kA (RMS value)
Permissible fuse cut-off current
kA (peak value)

6 150

3NP5060 0CA00
3NP5060 0CA00
3NP5060 0CB00
3NP5060 0CB10
3NP5260 0CA00
3NP5260 0CA10
3NP5260 0CB00
3NP5260 0CB10
3NP5360 0CA00
3NP5360 0CA10
3NP5460 0CA00
3NP5460 0CA10

With fuse monitoring

3NP50
50/60 Hz V AC
V DC

Basic versions

For 40 mm busbars1)

Technical data
Type

Selection and ordering data


3NP5 high end series

For 40 mm busbars
00/160
50
15

00/160
100
23

00
1,600
160
00
800
160
100

1/250 2/400 3/630


50
50
50
25
40
50

160 A

 for additional values refer to Catalog NSK, Section 12


(e. g. capacitor and DC switching capacity, switching capacity at 500 V AC, )

0
1,600
160
0
1,000
160
125

2
4,000
400
2
2,520
400
315

Flat pad connection


at the bottom
Clamp connection
at the bottom

Auxiliary contacts

2.5 120

1NO/1NC

3NP5065 1EF86

2.5 50

1NO/1NC

3NP5065 1EG86

400/500 V AC
2

1
2,500
250
1
1,600
250
200

3
5,040
630
3
3,200
630
400

2
4,000
400
2
2,520
400
315

2)

in mm

With electronic fuse monitoring

1/250 2/400 3/630


100
50
50
32
40
60

1
2,500
250
1
1,280
250
160

Size 00

6 240
6 2 x 240

For surface mounting and switchboard install. in mm

Auxiliary contacts

160 A

Size 00

Flat pad connection


Clamp connection

1NO/1NC
1NO/1NC

3NP5060 0HA13
3NP5060 0HB13

250 A
400 A
630 A

Size 1
Size 2
Size 3

Flat pad connection


Flat pad connection
Flat pad connection

1NO/1NC
1NO/1NC
1NO/1NC

3NP5260 0HA13
3NP5360 0HA13
3NP5460 0HA13

For 40 mm busbars1)
160 A

Size 00 at

Flat pad connection


the bottom

2.5 120
2.5 50
6 150
6 240
6 2 x 240
in mm2

Auxiliary contacts

2.5 120

1NO/1NC

3NP5065 1HF13

1) for mounting on 60 mm busbars, use devices for surface mounting and installation and 8US1 busbar adapters
2) optionally, 2 NO as signal outputs: Order No. 3NP5.E.26

3NP5 high end series Accessories


Accessories
for 3NP50
Size 00

for 3NP52
Size 1

for 3NP53
Size 2

for 3NP54
Size 3

Clamp connection
(1 set = 3 units)

3NY1903
2.5 50 mm2

3NY1907
35 120 mm2

Quick retaining plate


between 2 mounting
rails

3NY1995

Adapter
for mounting
on 60 mm
busbars

8US1291-4SB00

8US1210-4AG00

8US1210-4AG00

8US1210-4AG00

3NY1105
215 x 135

3NY1115
215 x 135

3NY1107
265 x 135

3NY1208
250 x 149

3NY1210
300 x 220

3NY1211
300 x 245

3NY1212
300 x 290

3NY1106
290 x 135

3NY1116
290 x 135

3NY1108

3NY1241

3NY1245

3NY1245

Auxiliary contacts
1NO/1NC
(= mounting set)

3NY3033

3NY3034

3NY3034

3NY3034

Sealing lug
can be retrofitted
(1 pkg. = 10 units)

3NY1940

Molded-plastic
masking frames
Dimensions (H x W):
for disconnectors
without/with auxiliary
contacts
Dimensions (H x W):
for disconnectors
with auxiliary contacts
Dimensions (H x W):
Masking frame
mounting set
Dimensions (H x W):
for mounting the disconnector in the front of
the switchgear panel
(masking frame and
mounting parts)
Cable lug cover
Masking frame (H x W)
for disconnectors without/
with auxiliary contacts
Masking frame (H x W)
for disconnectors
with auxiliary contacts
2 separate covers for
top/bottom
6 individual covers
(L = 120 mm)

 for spare parts, refer to Catalog NSK, Section 12


 for masking frames and mounting sets for 8HP molded-plastic distribution systems, refer to Catalog
8ZX1012-OHP54-5AB1
 for masking frames and mounting sets for SIKUS installation distribution panels, refer to Catalogs
I2.34 and 12.35

Subject to change without prior notice 08/02 | Bestell-Nr. EXXXXX-A190-PXXX | DISPO XXXXX | XXXXXXXXX PDWL.XX.X.XX WS 0802X.X | Printed in Germany

Fuses for overload and short-circuit protection means: high short-circuit currents

Siemens AG
Automation and Drives
Low Voltage Controls and Distribution
P. O. Box 32 40, D-91050 Erlangen
www.siemens.com/sentric

can also be safely handled, favorably-priced backup protection, simple selectivity calculations and absolute reliability, even when short-circuits occur. The fuse

3NP5 the rugged types for


the toughest applications

melts completely so that there is no residual risk as a result of contacts which


may have welded together. When the disconnector is in the open position,

Furthermore, 3NP5 have an extremely high AC-23


switching capacity. The switching gases which are
formed are deflected into the disconnector using a
sophisticated arc chamber design, instead of being
discharged upwards and to the side. This means
that operating personnel and plant sections and
components in the vicinity are reliably protected.

there is a visible isolating gap, which is often demanded, e. g. for maintenance


purposes. And the optional mounted fuse monitoring offers additional security
fuse switch disconnectors 3NP for the highest plant availability and safety.

Fuse monitoring:
To allow monitoring of the fuses in the disconnectors,
a permanently wired 3RV1 circuit-breaker is mounted
on the fuse carrier.

Fuses for your safety


3NP4 and 3NP5 switch disconnectors
ble to use other disconnectors available on the market. But the fast closing and arc deflection chambers
of the 3NP5 come through with flying colors. 3NP5
provides the highest degree of safety for operating
personnel and the plant, as main switch with high
switching frequency and good AC-23 characteristics,
e.g. for motor loads.
Both of these ranges are climate-proof and correspond to IEC 60 947-3 and VDE 0660, Part 107.
The fuses can be clearly identified through the large
clear inspection window.
Matching masking frames and complete, TSK-tested
mounting sets are available both for the moldedplastic 8HP distribution system as well as for the
various SIKUS distribution boards.
2 series in the range the optimum handle on
every application
The 3NP4 series (sizes NH000 to NH3) offer the
optimum solution for most applications. These range
from power distribution in residential and commercial buildings, through flexible distribution stations
up to power distribution systems in large industrial
plants.They are also admirably suited as main and
incoming feeder breakers in industry, for control
systems, as well as in motor feeders or as backup
protection for circuit-breakers. They have an integrated
lug for sealing which is integrated as standard.
This means that they can be used, without any
restrictions, in meter cabinets and incoming main
feeder boxes for buildings.
The rugged 3NP5 series (sizes NH00 to NH3)
provide reliable protection for all of the tougher
applications. This is especially true in mining, in the
steel industry, and also in the chemical industry,
where sulphur-laden, or aggressive ambient conditions or hazardous locations make it almost impossi-

The values for switching capacitors (e.g. for reactive


power compensation) were also tested (refer to
Catalog NSK, Section 12), and when used with SITOR
semiconductor or 3NE1 double-protection fuses,
3NP disconnectors can be used to protect soft starters,
AC drive converters and similar devices (tables with
tested device-fuse combinations are provided in the
NSK). Shock and vibration testing as well as special
earthquake tests guarantee that the 3NP can be used
in marine applications, nuclear power stations and
similar safety-critical plants.

high switching frequency for devices such as these.


The erosion electrodes additionally extend the lifetime of the main contacts. The lateral spring mechanism (= fast switching) eliminates any danger as
a result of incorrect operation, e.g. briefly actuating
the disconnector or switching which is too slow.

When the switch disconnector is in the ON position,


the circuit-braker poles are connected in parallel
with the fuses to be monitored. When the switch is
in the OFF position, the poles of the circuit-breaker
are dead.
The 3NP5 disconnector series (sizes NH00 to NH3)
for fixed installation can be quickly hung onto preinstalled mounting bolts. They can also be mounted
on the front of switchgear panels using the matching mounting sets or they can be mounted onto
60 mm busbar systems using 8US1 adapters.
The especially rugged design of this series (plastic
with a high resistance to heat, metal parts which can
be mechanically stressed), permits an unusually

The internal resistance of the circuit-breaker is so


high that it does not affect the protection given by
the monitored fuses.

Rated operational voltage Ue

Electronic fuse monitoring (EFM):


The electronic fuse monitoring system is also
mounted on the fuse carrier of the 3NP5. It works
whether or not a load is present. Fuse blowing can
be signalled to a switch control room by means of a
group indication (2NO contacts + 1NC contact).

For surface mounting and switchboard install. in mm

Auxiliary contacts

160 A

without
1NO/1NC
without
1NO/1NC
without
1NO/1NC
without
1NO/1NC
without
1NO/1NC
without
1NO/1NC

250 A

Size 00

Size 1

Flat pad connection

2.5 120

Clamp connection

2.5 50

Flat pad connection


Clamp connection

Short-circuit strength with fuse


(with the disconnector closed)
With fuse links
rated current
Size/A
For 500 V AC
kA (RMS value)
Permissible fuse cut-off current
kA (peak value)
Rated operating current and switching capacity
(supply from either the top or bottom)
For 400 V AC, with fuse links or isolating links
Size
Rated breaking current Ic (cos p = 0.35)
A (RMS value)
Rated operating current Ie for AC-21B up to AC-23B
A
For 690 V AC, with fuse links or isolating links
Size
Rated breaking current Ic (cos p = 0.35)
A (RMS value)
Rated operating current Ie for AC-21B, AC-22B
A
AC-23B
A

35 120

400 A

Size 2

Flat pad connection

6 240

630 A

Size 3

Flat pad connection

6 2 x 240

160 A

Size 00

in mm2

Auxiliary contacts

Flat pad connection


at the bottom

2.5 120

Clamp connection
at the bottom

2.5 50

without
1NO/1NC
without
1NO/1NC

3NP5065 1CF00
3NP5065 1CF10
3NP5065 1CG00
3NP5065 1CG10

400 690 V AC, 220 V DC

For surface mounting and switchboard install. in mm2

Auxiliary contacts2)

160 A

Size 00

Flat pad connection


Clamp connection

2.5 120
2.5 50

1NO/1NC
1NO/1NC

3NP5060 0EA86
3NP5060 0EB86

3NP54

250 A

Size 1

Flat pad connection


Clamp connection

6 150
35 120

1NO/1NC
1NO/1NC

3NP5260 0EA86
3NP5260 0EB86

690
440 (3 phases in series)
220 (2 phases in series with mounted fuse monitoring)

400 A
630 A

Size 2
Size 3

Flat pad connection


Flat pad connection

1NO/1NC
1NO/1NC

3NP5360 0EA86
3NP5460 0EA86

3NP52

3NP53

1)

Rated conditional short-circuit current with fuses


With fuse links
rated current
Size/A
For 500 V AC
kA (RMS value)
Permissible fuse cut-off current
kA (peak value)

6 150

3NP5060 0CA00
3NP5060 0CA00
3NP5060 0CB00
3NP5060 0CB10
3NP5260 0CA00
3NP5260 0CA10
3NP5260 0CB00
3NP5260 0CB10
3NP5360 0CA00
3NP5360 0CA10
3NP5460 0CA00
3NP5460 0CA10

With fuse monitoring

3NP50
50/60 Hz V AC
V DC

Basic versions

For 40 mm busbars1)

Technical data
Type

Selection and ordering data


3NP5 high end series

For 40 mm busbars
00/160
50
15

00/160
100
23

00
1,600
160
00
800
160
100

1/250 2/400 3/630


50
50
50
25
40
50

160 A

 for additional values refer to Catalog NSK, Section 12


(e. g. capacitor and DC switching capacity, switching capacity at 500 V AC, )

0
1,600
160
0
1,000
160
125

2
4,000
400
2
2,520
400
315

Flat pad connection


at the bottom
Clamp connection
at the bottom

Auxiliary contacts

2.5 120

1NO/1NC

3NP5065 1EF86

2.5 50

1NO/1NC

3NP5065 1EG86

400/500 V AC
2

1
2,500
250
1
1,600
250
200

3
5,040
630
3
3,200
630
400

2
4,000
400
2
2,520
400
315

2)

in mm

With electronic fuse monitoring

1/250 2/400 3/630


100
50
50
32
40
60

1
2,500
250
1
1,280
250
160

Size 00

6 240
6 2 x 240

For surface mounting and switchboard install. in mm

Auxiliary contacts

160 A

Size 00

Flat pad connection


Clamp connection

1NO/1NC
1NO/1NC

3NP5060 0HA13
3NP5060 0HB13

250 A
400 A
630 A

Size 1
Size 2
Size 3

Flat pad connection


Flat pad connection
Flat pad connection

1NO/1NC
1NO/1NC
1NO/1NC

3NP5260 0HA13
3NP5360 0HA13
3NP5460 0HA13

For 40 mm busbars1)
160 A

Size 00 at

Flat pad connection


the bottom

2.5 120
2.5 50
6 150
6 240
6 2 x 240
in mm2

Auxiliary contacts

2.5 120

1NO/1NC

3NP5065 1HF13

1) for mounting on 60 mm busbars, use devices for surface mounting and installation and 8US1 busbar adapters
2) optionally, 2 NO as signal outputs: Order No. 3NP5.E.26

3NP5 high end series Accessories


Accessories
for 3NP50
Size 00

for 3NP52
Size 1

for 3NP53
Size 2

for 3NP54
Size 3

Clamp connection
(1 set = 3 units)

3NY1903
2.5 50 mm2

3NY1907
35 120 mm2

Quick retaining plate


between 2 mounting
rails

3NY1995

Adapter
for mounting
on 60 mm
busbars

8US1291-4SB00

8US1210-4AG00

8US1210-4AG00

8US1210-4AG00

3NY1105
215 x 135

3NY1115
215 x 135

3NY1107
265 x 135

3NY1208
250 x 149

3NY1210
300 x 220

3NY1211
300 x 245

3NY1212
300 x 290

3NY1106
290 x 135

3NY1116
290 x 135

3NY1108

3NY1241

3NY1245

3NY1245

Auxiliary contacts
1NO/1NC
(= mounting set)

3NY3033

3NY3034

3NY3034

3NY3034

Sealing lug
can be retrofitted
(1 pkg. = 10 units)

3NY1940

Molded-plastic
masking frames
Dimensions (H x W):
for disconnectors
without/with auxiliary
contacts
Dimensions (H x W):
for disconnectors
with auxiliary contacts
Dimensions (H x W):
Masking frame
mounting set
Dimensions (H x W):
for mounting the disconnector in the front of
the switchgear panel
(masking frame and
mounting parts)
Cable lug cover
Masking frame (H x W)
for disconnectors without/
with auxiliary contacts
Masking frame (H x W)
for disconnectors
with auxiliary contacts
2 separate covers for
top/bottom
6 individual covers
(L = 120 mm)

 for spare parts, refer to Catalog NSK, Section 12


 for masking frames and mounting sets for 8HP molded-plastic distribution systems, refer to Catalog
8ZX1012-OHP54-5AB1
 for masking frames and mounting sets for SIKUS installation distribution panels, refer to Catalogs
I2.34 and 12.35

Subject to change without prior notice 08/02 | Bestell-Nr. EXXXXX-A190-PXXX | DISPO XXXXX | XXXXXXXXX PDWL.XX.X.XX WS 0802X.X | Printed in Germany

Fuses for overload and short-circuit protection means: high short-circuit currents

Siemens AG
Automation and Drives
Low Voltage Controls and Distribution
P. O. Box 32 40, D-91050 Erlangen
www.siemens.com/sentric

can also be safely handled, favorably-priced backup protection, simple selectivity calculations and absolute reliability, even when short-circuits occur. The fuse

3NP5 the rugged types for


the toughest applications

melts completely so that there is no residual risk as a result of contacts which


may have welded together. When the disconnector is in the open position,

Furthermore, 3NP5 have an extremely high AC-23


switching capacity. The switching gases which are
formed are deflected into the disconnector using a
sophisticated arc chamber design, instead of being
discharged upwards and to the side. This means
that operating personnel and plant sections and
components in the vicinity are reliably protected.

there is a visible isolating gap, which is often demanded, e. g. for maintenance


purposes. And the optional mounted fuse monitoring offers additional security
fuse switch disconnectors 3NP for the highest plant availability and safety.

Fuse monitoring:
To allow monitoring of the fuses in the disconnectors,
a permanently wired 3RV1 circuit-breaker is mounted
on the fuse carrier.

Fuses for your safety


3NP4 and 3NP5 switch disconnectors
ble to use other disconnectors available on the market. But the fast closing and arc deflection chambers
of the 3NP5 come through with flying colors. 3NP5
provides the highest degree of safety for operating
personnel and the plant, as main switch with high
switching frequency and good AC-23 characteristics,
e.g. for motor loads.
Both of these ranges are climate-proof and correspond to IEC 60 947-3 and VDE 0660, Part 107.
The fuses can be clearly identified through the large
clear inspection window.
Matching masking frames and complete, TSK-tested
mounting sets are available both for the moldedplastic 8HP distribution system as well as for the
various SIKUS distribution boards.
2 series in the range the optimum handle on
every application
The 3NP4 series (sizes NH000 to NH3) offer the
optimum solution for most applications. These range
from power distribution in residential and commercial buildings, through flexible distribution stations
up to power distribution systems in large industrial
plants.They are also admirably suited as main and
incoming feeder breakers in industry, for control
systems, as well as in motor feeders or as backup
protection for circuit-breakers. They have an integrated
lug for sealing which is integrated as standard.
This means that they can be used, without any
restrictions, in meter cabinets and incoming main
feeder boxes for buildings.
The rugged 3NP5 series (sizes NH00 to NH3)
provide reliable protection for all of the tougher
applications. This is especially true in mining, in the
steel industry, and also in the chemical industry,
where sulphur-laden, or aggressive ambient conditions or hazardous locations make it almost impossi-

The values for switching capacitors (e.g. for reactive


power compensation) were also tested (refer to
Catalog NSK, Section 12), and when used with SITOR
semiconductor or 3NE1 double-protection fuses,
3NP disconnectors can be used to protect soft starters,
AC drive converters and similar devices (tables with
tested device-fuse combinations are provided in the
NSK). Shock and vibration testing as well as special
earthquake tests guarantee that the 3NP can be used
in marine applications, nuclear power stations and
similar safety-critical plants.

high switching frequency for devices such as these.


The erosion electrodes additionally extend the lifetime of the main contacts. The lateral spring mechanism (= fast switching) eliminates any danger as
a result of incorrect operation, e.g. briefly actuating
the disconnector or switching which is too slow.

When the switch disconnector is in the ON position,


the circuit-braker poles are connected in parallel
with the fuses to be monitored. When the switch is
in the OFF position, the poles of the circuit-breaker
are dead.
The 3NP5 disconnector series (sizes NH00 to NH3)
for fixed installation can be quickly hung onto preinstalled mounting bolts. They can also be mounted
on the front of switchgear panels using the matching mounting sets or they can be mounted onto
60 mm busbar systems using 8US1 adapters.
The especially rugged design of this series (plastic
with a high resistance to heat, metal parts which can
be mechanically stressed), permits an unusually

The internal resistance of the circuit-breaker is so


high that it does not affect the protection given by
the monitored fuses.

Rated operational voltage Ue

Electronic fuse monitoring (EFM):


The electronic fuse monitoring system is also
mounted on the fuse carrier of the 3NP5. It works
whether or not a load is present. Fuse blowing can
be signalled to a switch control room by means of a
group indication (2NO contacts + 1NC contact).

For surface mounting and switchboard install. in mm

Auxiliary contacts

160 A

without
1NO/1NC
without
1NO/1NC
without
1NO/1NC
without
1NO/1NC
without
1NO/1NC
without
1NO/1NC

250 A

Size 00

Size 1

Flat pad connection

2.5 120

Clamp connection

2.5 50

Flat pad connection


Clamp connection

Short-circuit strength with fuse


(with the disconnector closed)
With fuse links
rated current
Size/A
For 500 V AC
kA (RMS value)
Permissible fuse cut-off current
kA (peak value)
Rated operating current and switching capacity
(supply from either the top or bottom)
For 400 V AC, with fuse links or isolating links
Size
Rated breaking current Ic (cos p = 0.35)
A (RMS value)
Rated operating current Ie for AC-21B up to AC-23B
A
For 690 V AC, with fuse links or isolating links
Size
Rated breaking current Ic (cos p = 0.35)
A (RMS value)
Rated operating current Ie for AC-21B, AC-22B
A
AC-23B
A

35 120

400 A

Size 2

Flat pad connection

6 240

630 A

Size 3

Flat pad connection

6 2 x 240

160 A

Size 00

in mm2

Auxiliary contacts

Flat pad connection


at the bottom

2.5 120

Clamp connection
at the bottom

2.5 50

without
1NO/1NC
without
1NO/1NC

3NP5065 1CF00
3NP5065 1CF10
3NP5065 1CG00
3NP5065 1CG10

400 690 V AC, 220 V DC

For surface mounting and switchboard install. in mm2

Auxiliary contacts2)

160 A

Size 00

Flat pad connection


Clamp connection

2.5 120
2.5 50

1NO/1NC
1NO/1NC

3NP5060 0EA86
3NP5060 0EB86

3NP54

250 A

Size 1

Flat pad connection


Clamp connection

6 150
35 120

1NO/1NC
1NO/1NC

3NP5260 0EA86
3NP5260 0EB86

690
440 (3 phases in series)
220 (2 phases in series with mounted fuse monitoring)

400 A
630 A

Size 2
Size 3

Flat pad connection


Flat pad connection

1NO/1NC
1NO/1NC

3NP5360 0EA86
3NP5460 0EA86

3NP52

3NP53

1)

Rated conditional short-circuit current with fuses


With fuse links
rated current
Size/A
For 500 V AC
kA (RMS value)
Permissible fuse cut-off current
kA (peak value)

6 150

3NP5060 0CA00
3NP5060 0CA00
3NP5060 0CB00
3NP5060 0CB10
3NP5260 0CA00
3NP5260 0CA10
3NP5260 0CB00
3NP5260 0CB10
3NP5360 0CA00
3NP5360 0CA10
3NP5460 0CA00
3NP5460 0CA10

With fuse monitoring

3NP50
50/60 Hz V AC
V DC

Basic versions

For 40 mm busbars1)

Technical data
Type

Selection and ordering data


3NP5 high end series

For 40 mm busbars
00/160
50
15

00/160
100
23

00
1,600
160
00
800
160
100

1/250 2/400 3/630


50
50
50
25
40
50

160 A

 for additional values refer to Catalog NSK, Section 12


(e. g. capacitor and DC switching capacity, switching capacity at 500 V AC, )

0
1,600
160
0
1,000
160
125

2
4,000
400
2
2,520
400
315

Flat pad connection


at the bottom
Clamp connection
at the bottom

Auxiliary contacts

2.5 120

1NO/1NC

3NP5065 1EF86

2.5 50

1NO/1NC

3NP5065 1EG86

400/500 V AC
2

1
2,500
250
1
1,600
250
200

3
5,040
630
3
3,200
630
400

2
4,000
400
2
2,520
400
315

2)

in mm

With electronic fuse monitoring

1/250 2/400 3/630


100
50
50
32
40
60

1
2,500
250
1
1,280
250
160

Size 00

6 240
6 2 x 240

For surface mounting and switchboard install. in mm

Auxiliary contacts

160 A

Size 00

Flat pad connection


Clamp connection

1NO/1NC
1NO/1NC

3NP5060 0HA13
3NP5060 0HB13

250 A
400 A
630 A

Size 1
Size 2
Size 3

Flat pad connection


Flat pad connection
Flat pad connection

1NO/1NC
1NO/1NC
1NO/1NC

3NP5260 0HA13
3NP5360 0HA13
3NP5460 0HA13

For 40 mm busbars1)
160 A

Size 00 at

Flat pad connection


the bottom

2.5 120
2.5 50
6 150
6 240
6 2 x 240
in mm2

Auxiliary contacts

2.5 120

1NO/1NC

3NP5065 1HF13

1) for mounting on 60 mm busbars, use devices for surface mounting and installation and 8US1 busbar adapters
2) optionally, 2 NO as signal outputs: Order No. 3NP5.E.26

3NP5 high end series Accessories


Accessories
for 3NP50
Size 00

for 3NP52
Size 1

for 3NP53
Size 2

for 3NP54
Size 3

Clamp connection
(1 set = 3 units)

3NY1903
2.5 50 mm2

3NY1907
35 120 mm2

Quick retaining plate


between 2 mounting
rails

3NY1995

Adapter
for mounting
on 60 mm
busbars

8US1291-4SB00

8US1210-4AG00

8US1210-4AG00

8US1210-4AG00

3NY1105
215 x 135

3NY1115
215 x 135

3NY1107
265 x 135

3NY1208
250 x 149

3NY1210
300 x 220

3NY1211
300 x 245

3NY1212
300 x 290

3NY1106
290 x 135

3NY1116
290 x 135

3NY1108

3NY1241

3NY1245

3NY1245

Auxiliary contacts
1NO/1NC
(= mounting set)

3NY3033

3NY3034

3NY3034

3NY3034

Sealing lug
can be retrofitted
(1 pkg. = 10 units)

3NY1940

Molded-plastic
masking frames
Dimensions (H x W):
for disconnectors
without/with auxiliary
contacts
Dimensions (H x W):
for disconnectors
with auxiliary contacts
Dimensions (H x W):
Masking frame
mounting set
Dimensions (H x W):
for mounting the disconnector in the front of
the switchgear panel
(masking frame and
mounting parts)
Cable lug cover
Masking frame (H x W)
for disconnectors without/
with auxiliary contacts
Masking frame (H x W)
for disconnectors
with auxiliary contacts
2 separate covers for
top/bottom
6 individual covers
(L = 120 mm)

 for spare parts, refer to Catalog NSK, Section 12


 for masking frames and mounting sets for 8HP molded-plastic distribution systems, refer to Catalog
8ZX1012-OHP54-5AB1
 for masking frames and mounting sets for SIKUS installation distribution panels, refer to Catalogs
I2.34 and 12.35

Subject to change without prior notice 08/02 | Bestell-Nr. EXXXXX-A190-PXXX | DISPO XXXXX | XXXXXXXXX PDWL.XX.X.XX WS 0802X.X | Printed in Germany

Fuses for overload and short-circuit protection means: high short-circuit currents

Siemens AG
Automation and Drives
Low Voltage Controls and Distribution
P. O. Box 32 40, D-91050 Erlangen
www.siemens.com/sentric

Selection and ordering data


3NP4 standard series

3NP4 standard
Accessories

for 3
Size

Basic versions
For surface mounting and switchboard install.

Connection in mm2

160 A1)
160 A

Size 000
Size 00

250 A
400 A
630 A

Size
Size
Size

1.5 50
up to 2 x 70 (M8)
2.5 70
up to 150 (M10)
up to 240 (M12)
up to 2 x 240 (M12)

1
2
3

SIGUT terminal
Flat pad connection
SIGUT terminal
Flat pad connection
Flat pad connection
Flat pad connection

For 40 mm busbars2)
160 A1)

160 A

Size 000

Size 00

Connection in mm2
SIGUT terminal

Flat pad connection

SIGUT terminal

250 A

Size

Flat pad connection

For 60 mm busbars
160 A1)

160 A

Size 000

Size 00

400 A
630 A

Size
Size
Size

1
2
3

With fuse monitoring

1.5 50
Connection, top
Connection, bottom

3NP4015 1CK01
3NP4015 1CJ01

up to 2 x 70 (M8)
Connection, top
Connection, bottom

3NP4075 1CE01
3NP4075 1CF01

2.5 70
Connection, top
Connection, bottom

3NP4075 1CK01
3NP4075 1CJ01

up to 150 (M10)
top or bottom3)

3NP4275 1CG01

Connection in mm

SIGUT terminal

Flat pad connection

SIGUT terminal

250 A

3NP4010 0CH10
3NP4070 0CA01
3NP4070 0CH01
3NP4270 0CA01
3NP4370 0CA10
3NP4470 0CA01

Flat pad connection


Flat pad connection
Flat pad connection

1.5 50
Connection, top
Connection, bottom

3NP4016 1CK01
3NP4016 1CJ01

up to 2 x 70 (M8)
Connection, top
Connection, bottom

3NP4076 1CE01
3NP4076 1CF01

2.5 70
Connection, top
Connection, bottom

3NP4076 1CK01
3NP4076 1CJ01

up to 150 (M10)
top or bottom3)

3NP4276 1CG01

up to 240 (M12)
top or bottom3)

3NP4376 1CG01

up to 2 x 240 (M12)
top or bottom3)

3NP4476 1CG01

400 690 V AC, 220 V DC

 all of the versions specified above (except size 000) are also available with mounted fuse
monitoring; Order No. supplement: 3NP4.F.01
1) 125 and 160 A only with special, 21-mm-wide fuses 3NY1822 and 3NY1824, refer to Accessories
2) Adapter depth, 28 mm; for disconnectors with deeper adapters (49 mm), refer to Catalog NSK, Section 12
3) Connection modules can be replaced, refer to the Instruction Manual

Connection terminals
(1 set = 3 units) connection:

inte

Cable lug cover


(1 set = 3 units) safe from
finger touch cover of the flat
pad connection acc. to VBG4

not

Auxiliary contact,
1 changeover contact
normal version
electronics-compatible
Quick retaining plate
to mount the disconnectors
between two mounting rails
(125 mm clearance)

3NY
3NY

3NY

Busbar width compensation


only for 5 mm busbars
not
for 10 mm busbars
brea
Three-way terminal
(1 set = 3 units) to connect
3 x 2.5 16 mm2 (e/m) or
3 x 2.5 10 mm2 (finely
stranded with end sleeves)
for mounting onto a
SIGUT terminal
for mounting onto a
flat pad connection
3-phase busbars
for 2 disconnectors
for 3 disconnectors
for 4 disconnectors
connecting buses
for > 4 disconnectors
cap for empty location (20x units):
Incoming supply terminal
(1 set = 3 units) for conductors e/m: up to 95 mm2
finely stranded with end
sleeves: up to 70 mm2

3NY

3NY
3NY
3NY

3NY
3NY

3NY

Fuse links, size 000


21 mm wide, Duty class gL/gC
400 V/125 A
3NY
400 V/160 A
3NY
Sealing pin
can be retrofitted
(1 pkg. = 10 units)
Masking frames
for mounting in general
distribution systems
for disconnectors with
SIGUT terminal
for disconnectors with
flat pad connection
Dimensions (H x W):
Overreach protection
(10 units)

inte

3NY

215

inte

 for spare parts, refer to Catalog N


 for masking frames and mountin
E20001-8ZX1012-OHP54-5AB1

Selection and ordering data


3NP4 standard series

3NP4 standard series Accessories


Accessories

Basic versions
For surface mounting and switchboard install.

Connection in mm2

160 A1)
160 A

Size 000
Size 00

250 A
400 A
630 A

Size
Size
Size

1.5 50
up to 2 x 70 (M8)
2.5 70
up to 150 (M10)
up to 240 (M12)
up to 2 x 240 (M12)

1
2
3

SIGUT terminal
Flat pad connection
SIGUT terminal
Flat pad connection
Flat pad connection
Flat pad connection

For 40 mm busbars2)
160 A1)

160 A

Size 000

Size 00

Connection in mm2
SIGUT terminal

Flat pad connection

SIGUT terminal

250 A

Size

Flat pad connection

For 60 mm busbars
160 A1)

160 A

Size 000

Size 00

400 A
630 A

Size
Size
Size

1
2
3

With fuse monitoring

1.5 50
Connection, top
Connection, bottom

3NP4015 1CK01
3NP4015 1CJ01

up to 2 x 70 (M8)
Connection, top
Connection, bottom

3NP4075 1CE01
3NP4075 1CF01

2.5 70
Connection, top
Connection, bottom

3NP4075 1CK01
3NP4075 1CJ01

up to 150 (M10)
top or bottom3)

3NP4275 1CG01

Connection in mm

SIGUT terminal

Flat pad connection

SIGUT terminal

250 A

3NP4010 0CH10
3NP4070 0CA01
3NP4070 0CH01
3NP4270 0CA01
3NP4370 0CA10
3NP4470 0CA01

Flat pad connection


Flat pad connection
Flat pad connection

1.5 50
Connection, top
Connection, bottom

3NP4016 1CK01
3NP4016 1CJ01

up to 2 x 70 (M8)
Connection, top
Connection, bottom

3NP4076 1CE01
3NP4076 1CF01

2.5 70
Connection, top
Connection, bottom

3NP4076 1CK01
3NP4076 1CJ01

up to 150 (M10)
top or bottom3)

3NP4276 1CG01

up to 240 (M12)
top or bottom3)

3NP4376 1CG01

up to 2 x 240 (M12)
top or bottom3)

3NP4476 1CG01

400 690 V AC, 220 V DC

 all of the versions specified above (except size 000) are also available with mounted fuse
monitoring; Order No. supplement: 3NP4.F.01
1) 125 and 160 A only with special, 21-mm-wide fuses 3NY1822 and 3NY1824, refer to Accessories
2) Adapter depth, 28 mm; for disconnectors with deeper adapters (49 mm), refer to Catalog NSK, Section 12
3) Connection modules can be replaced, refer to the Instruction Manual

for 3NP401
Size 000

for 3NP407
Size 00

for 3NP42
Size 1

for 3NP43
Size 2

Connection terminals
(1 set = 3 units) connection:

integrated

integrated

3NY7120
70 150 mm2

3NY7130
3NY7140
120 240 mm2 150 300 mm2

Cable lug cover


(1 set = 3 units) safe from
finger touch cover of the flat
pad connection acc. to VBG4

not required

3NY7101

3NY7121

3NY7131

3NY7141

3NY3035
3NY3030

3NY3035
3NY3030

3NY3035
3NY3030

3NY3035
3NY3030

3NY3035
3NY3030

3NY1995

3NY1995

3NY7322

Auxiliary contact,
1 changeover contact
normal version
electronics-compatible
Quick retaining plate
to mount the disconnectors
between two mounting rails
(125 mm clearance)

for 3NP44
Size 3

3NP4 quickly mou

Busbar width compensation


only for 5 mm busbars
not required
for 10 mm busbars
break-off

not required
break-off

3NY7381
not required

3NY7381
not required

not possible
not required

3NY7102

3NY7102

3NY7105

3NY1237
3NY1238
3NY1438

3NY1263
3NY1265

3NY1236

Fuse links, size 000


21 mm wide, Duty class gL/gC
400 V/125 A
3NY1822
400 V/160 A
3NY1824

integrated

integrated

3NY7482

3NY7482

3NY7482

3NY1251

3NY7200

215 x 130

3NY7201
215 x 130

3NY7220
375 x 220

3NY7230
375 x 245

3NY7240
375 x 290

integrated

integrated

3NY7481

3NY7481

3NY7481

Three-way terminal
(1 set = 3 units) to connect
3 x 2.5 16 mm2 (e/m) or
3 x 2.5 10 mm2 (finely
stranded with end sleeves)
for mounting onto a
SIGUT terminal
for mounting onto a
flat pad connection
3-phase busbars
for 2 disconnectors
for 3 disconnectors
for 4 disconnectors
connecting buses
for > 4 disconnectors
cap for empty location (20x units):
Incoming supply terminal
(1 set = 3 units) for conductors e/m: up to 95 mm2
finely stranded with end
sleeves: up to 70 mm2

Sealing pin
can be retrofitted
(1 pkg. = 10 units)
Masking frames
for mounting in general
distribution systems
for disconnectors with
SIGUT terminal
for disconnectors with
flat pad connection
Dimensions (H x W):
Overreach protection
(10 units)

 for spare parts, refer to Catalog NSK, Section 12


 for masking frames and mounting sets for 8HP molded-plastic distribution systems, refer to Catalog
E20001-8ZX1012-OHP54-5AB1

All-around safety
With the cable lug covers cor
enclosed disconnectors offer
protection, even after a volta
holes in the withdrawable fus
with SIGUT terminals are com
touch without any additional

The large clear inspection win


and the operating statuses of
quickly and reliably identified
around touch protection is al
the withdrawable fuse carrier
Size 1 shock protection is ava

At home on all busbars


All 3NP4 sizes are available fo
busbar center clearance. Busb
10 mm wide. For 10 mm bus
00, two lugs must be broken
busbar clamps. Busbar compe
as accessory for mounting siz
busbars (size 3 disconnectors
snapped onto 5 mm busbars)

By simply snapping onto the


the disconnectors can also be
double T profiles as well as on
from the Rittal company, with
of the busbars preventing this

Selection and ordering data


3NP4 standard series

3NP4 standard series Accessories


Accessories

Basic versions
For surface mounting and switchboard install.

Connection in mm2

160 A1)
160 A

Size 000
Size 00

250 A
400 A
630 A

Size
Size
Size

1.5 50
up to 2 x 70 (M8)
2.5 70
up to 150 (M10)
up to 240 (M12)
up to 2 x 240 (M12)

1
2
3

SIGUT terminal
Flat pad connection
SIGUT terminal
Flat pad connection
Flat pad connection
Flat pad connection

For 40 mm busbars2)
160 A1)

160 A

Size 000

Size 00

Flat pad connection

SIGUT terminal

250 A

Size

Flat pad connection

For 60 mm busbars
160 A1)

160 A

Size 000

Size 00

400 A
630 A

Size
Size
Size

1
2
3

With fuse monitoring

1.5 50
Connection, top
Connection, bottom
up to 2 x 70 (M8)
Connection, top
Connection, bottom
2.5 70
Connection, top
Connection, bottom
up to 150 (M10)
top or bottom3)

3NP4015 1CK01
3NP4015 1CJ01
3NP4075 1CE01
3NP4075 1CF01
3NP4075 1CK01
3NP4075 1CJ01
3NP4275 1CG01

Connection in mm2
SIGUT terminal

Flat pad connection

SIGUT terminal

250 A

3NP4010 0CH10
3NP4070 0CA01
3NP4070 0CH01
3NP4270 0CA01
3NP4370 0CA10
3NP4470 0CA01

Connection in mm2
SIGUT terminal

Flat pad connection


Flat pad connection
Flat pad connection

By simply snapping onto the busbars from the top,


the disconnectors can also be mounted onto T or
double T profiles as well as onto Power-Line systems
from the Rittal company, without the horizontal parts
of the busbars preventing this.

1.5 50
Connection, top
Connection, bottom

3NP4016 1CK01
3NP4016 1CJ01

up to 2 x 70 (M8)
Connection, top
Connection, bottom

3NP4076 1CE01
3NP4076 1CF01

2.5 70
Connection, top
Connection, bottom

3NP4076 1CK01
3NP4076 1CJ01

up to 150 (M10)
top or bottom3)

3NP4276 1CG01

up to 240 (M12)
top or bottom3)

3NP4376 1CG01

up to 2 x 240 (M12)
top or bottom3)

3NP4476 1CG01

400 690 V AC, 220 V DC

 all of the versions specified above (except size 000) are also available with mounted fuse
monitoring; Order No. supplement: 3NP4.F.01
1) 125 and 160 A only with special, 21-mm-wide fuses 3NY1822 and 3NY1824, refer to Accessories
2) Adapter depth, 28 mm; for disconnectors with deeper adapters (49 mm), refer to Catalog NSK, Section 12
3) Connection modules can be replaced, refer to the Instruction Manual

for 3NP401
Size 000

for 3NP407
Size 00

for 3NP42
Size 1

for 3NP43
Size 2

Connection terminals
(1 set = 3 units) connection:

integrated

integrated

3NY7120
70 150 mm2

3NY7130
3NY7140
120 240 mm2 150 300 mm2

Cable lug cover


(1 set = 3 units) safe from
finger touch cover of the flat
pad connection acc. to VBG4

not required

3NY7101

3NY7121

3NY7131

Auxiliary contact,
1 changeover contact
normal version
electronics-compatible
Quick retaining plate
to mount the disconnectors
between two mounting rails
(125 mm clearance)

3NY3035
3NY3030

3NY3035
3NY3030

3NY3035
3NY3030

3NY3035
3NY3030

3NY1995

3NY1995

3NY7322

3-phase busbars
for 2 disconnectors
for 3 disconnectors
for 4 disconnectors
connecting buses
for > 4 disconnectors
cap for empty location (20x units):
Incoming supply terminal
(1 set = 3 units) for conductors e/m: up to 95 mm2
finely stranded with end
sleeves: up to 70 mm2

Masking frames
for mounting in general
distribution systems
for disconnectors with
SIGUT terminal
for disconnectors with
flat pad connection
Dimensions (H x W):
Overreach protection
(10 units)

The circuit-breaker is connected in parallel to the


three main disconnector phases, and is tripped as
soon as at least one of three fuses blows. The voltage
is tapped at the handle lugs of the fuses which means
that only fuses with live grip lugs can be used.

not required
break-off

3NY7381
not required

3NY7381
not required

not possible
not required

3NY7102

3NY7102

3NY7105

3NY1237
3NY1238
3NY1438

3NY1263
3NY1265

3NY1236

integrated

integrated

3NY7482

3NY7482

3NY7482

3NY1251

3NY7200

215 x 130

3NY7201
215 x 130

3NY7220
375 x 220

3NY7230
375 x 245

3NY7240
375 x 290

integrated

integrated

3NY7481

3NY7481

3NY7481

 for spare parts, refer to Catalog NSK, Section 12


 for masking frames and mounting sets for 8HP molded-plastic distribution systems, refer to Catalog
E20001-8ZX1012-OHP54-5AB1

This button prevents the shock protection from


being inserted as long as the latching mechanism
hasnt correctly latched into place.

Allaround safety
With the cable lug covers correctly
mounted, the enclosed disconnectors offer a high IP
30 degree of protection, even after a voltage test
using the 6 test holes in the withdrawable fuse carrier. The versions with SIGUT terminals are completely
safe from finger touch without any additional covers.
The large clear inspection window allows the type
and the operating statuses of the fuse links to be
quickly and reliably identified. Overreach and reacharound touch protection is already integrated into
the withdrawable fuse carrier up to 160 A; from
Size 1 shock protection is available as accessory.
At home on all busbars
All 3NP4 sizes are available for 40 mm or 60 mm
busbar center clearance. Busbars can either be 5 or
10 mm wide. For 10 mm busbars, for sizes 000 and
00, two lugs must be broken off at the three rear
busbar clamps. Busbar compensation is available
as accessory for mounting sizes 1 and 2 onto 5 mm
busbars (size 3 disconnectors cannot only be
snapped onto 5 mm busbars).

Quickly mounted
All of these features reduce valuable mounting
and installation time. It also means that the correct
tightening torque of the screws doesnt have to be
checked and adjusted. The mounting rail latching
mechanisms, integrated into the basic size 000 and
00 devices, also provide a clear financial benefit,
especially, where up to 160 A disconnectors are used
in larger unit quantities: additional screws, hooks,
intermediate plates or a second mounting rail are
not required.
Smart accessories for every
application
The auxiliary contacts, which fit all sizes, can be
subsequently retrofitted without taking up any
extra space.
The three-way terminal makes it easy to connect
up to 3 cables (e. g. for capacitor protection).
Several disconnectors can be fed in parallel using
the 3-phase busbars, connecting buses and feeder
terminals up to 225 A. Numerous masking frames
and mounting sets for SIKUS distribution boards or
the 8HP distribution system guarantee simple engineering and fast mounting and installation.

3NP Fuse Switch Disconnector


the Optimum Handle on Every Application

1NO/1NC signal outputs are used as standard. For


size 00, they are brought out to a connector socket
at the front, and for sizes 1 to 3, as double AMP flat
connector at the shock protection in the lower section
of the disconnector.
Either pre-assembled 1- or 3-m cables with strain
relief can be used as connecting cable for size 00.
These can then be easily inserted at the fuse monitoring using the mounted connectors. There are also
connector mounting sets for crimping (short-circuit
proof) cables.

3NP4 quickly mounted onto all busbars

Fuse links, size 000


21 mm wide, Duty class gL/gC
400 V/125 A
3NY1822
400 V/160 A
3NY1824
Sealing pin
can be retrofitted
(1 pkg. = 10 units)

can frequently occur, e. g. in line supplies with AC


drive converters and inverters.

Intelligent latching mechanism


This automatically adapts itself to busbar widths
between 5 and 30 mm, and it reliably latches into
place. This eliminates numerous versions and
complicated adjustments before mounting. There
is a small red button inside the switch, which,
especially from size 1, ensures that the disconnector
is really mounted onto the busbar to its endstop.

3NY7141

3NY3035
3NY3030

Busbar width compensation


only for 5 mm busbars
not required
for 10 mm busbars
break-off
Three-way terminal
(1 set = 3 units) to connect
3 x 2.5 16 mm2 (e/m) or
3 x 2.5 10 mm2 (finely
stranded with end sleeves)
for mounting onto a
SIGUT terminal
for mounting onto a
flat pad connection

for 3NP44
Size 3

Fuse monitoring for 3NP4

From size NH00 onwards, all of the 3NP4 versions are


also available with fuse monitoring. This is realized
using 3RV SIRIUS circuit-breakers which are mounted
at the front in the center of the fuse carrier.

Flat connectors are always used for sizes 13.

The disconnector can then be fed as required from


either the top or the bottom, whereby voltages up to
690 V AC/220 V DC are possible. Furthermore, this
type of fuse monitoring is completely insensitive to
EMC disturbances and harmonics. These disturbances

The function of the 3RV can be tested at any time


using the test button provided.

Technical data
Type
Rated operational voltage Ue

3NP401
AC 50/60 Hz V
DC V

3NP40 7

3NP42

3NP43

3NP44

690
690
220 (3 phases in series)
440 (2 phases in series)
with mounted fuse monitoring upt to 220 V DC max.

Rated conditional short-circuit current with fuses


(for fast closing)
With fuse links
rated current
Size/A
For 400 V AC (690 V)
kA (RMS value)
Permissible fuse cut-off current
kA (peak value)

000/100 (35) 00/160


50 (50)
50
11 (5)
15

1/250
50
25

2/400
50
35

3/630
50
55

Short-circuit strength with fuse


(with the disconnector closed)
With fuse links
rated current
Size/A
Up to 690 V
kA (RMS value)
Permissible fuse cut-off current
kA (peak value)

000/100
100
15

00/160
50
15

1/250
50
25

2/400
50
35

3/630
50
55

Rated operational current and switching capacity


(supply from either the top or bottom)
For 400 V AC, with fuse links or isolating links
Size
Rated breaking current Ic (cos p = 0.35) A (RMS value)
Rated operating current Ie for AC-21B, AC-22B
A
AC-23B
A

000
800
160
100

00
800
160
100

1
2,000
250
250

2
3,200
400
400

3
5,040
630
630

For 690 V AC, with fuse links or isolating links


Size
Rated breaking current Ic (cos p = 0.35) A (RMS value)
Rated operating current Ie for AC-21B
A
AC-22B
A
AC-23B
A

000
240
160
50
25

00
240
160
50
25

1
375
250

2
600
400

3
945
630

 for additional values, refer to Catalog NSK, Section 12 (e. g. capacitor and DC switching capacity, switching capacity
at 500 V AC, ...)

sentric

Selection and ordering data


3NP4 standard series

3NP4 standard series Accessories


Accessories

Basic versions
For surface mounting and switchboard install.

Connection in mm2

160 A1)
160 A

Size 000
Size 00

250 A
400 A
630 A

Size
Size
Size

1.5 50
up to 2 x 70 (M8)
2.5 70
up to 150 (M10)
up to 240 (M12)
up to 2 x 240 (M12)

1
2
3

SIGUT terminal
Flat pad connection
SIGUT terminal
Flat pad connection
Flat pad connection
Flat pad connection

For 40 mm busbars2)
160 A1)

160 A

Size 000

Size 00

Flat pad connection

SIGUT terminal

250 A

Size

Flat pad connection

For 60 mm busbars
160 A1)

160 A

Size 000

Size 00

400 A
630 A

Size
Size
Size

1
2
3

With fuse monitoring

1.5 50
Connection, top
Connection, bottom
up to 2 x 70 (M8)
Connection, top
Connection, bottom
2.5 70
Connection, top
Connection, bottom
up to 150 (M10)
top or bottom3)

3NP4015 1CK01
3NP4015 1CJ01
3NP4075 1CE01
3NP4075 1CF01
3NP4075 1CK01
3NP4075 1CJ01
3NP4275 1CG01

Connection in mm2
SIGUT terminal

Flat pad connection

SIGUT terminal

250 A

3NP4010 0CH10
3NP4070 0CA01
3NP4070 0CH01
3NP4270 0CA01
3NP4370 0CA10
3NP4470 0CA01

Connection in mm2
SIGUT terminal

Flat pad connection


Flat pad connection
Flat pad connection

By simply snapping onto the busbars from the top,


the disconnectors can also be mounted onto T or
double T profiles as well as onto Power-Line systems
from the Rittal company, without the horizontal parts
of the busbars preventing this.

1.5 50
Connection, top
Connection, bottom

3NP4016 1CK01
3NP4016 1CJ01

up to 2 x 70 (M8)
Connection, top
Connection, bottom

3NP4076 1CE01
3NP4076 1CF01

2.5 70
Connection, top
Connection, bottom

3NP4076 1CK01
3NP4076 1CJ01

up to 150 (M10)
top or bottom3)

3NP4276 1CG01

up to 240 (M12)
top or bottom3)

3NP4376 1CG01

up to 2 x 240 (M12)
top or bottom3)

3NP4476 1CG01

400 690 V AC, 220 V DC

 all of the versions specified above (except size 000) are also available with mounted fuse
monitoring; Order No. supplement: 3NP4.F.01
1) 125 and 160 A only with special, 21-mm-wide fuses 3NY1822 and 3NY1824, refer to Accessories
2) Adapter depth, 28 mm; for disconnectors with deeper adapters (49 mm), refer to Catalog NSK, Section 12
3) Connection modules can be replaced, refer to the Instruction Manual

for 3NP401
Size 000

for 3NP407
Size 00

for 3NP42
Size 1

for 3NP43
Size 2

Connection terminals
(1 set = 3 units) connection:

integrated

integrated

3NY7120
70 150 mm2

3NY7130
3NY7140
120 240 mm2 150 300 mm2

Cable lug cover


(1 set = 3 units) safe from
finger touch cover of the flat
pad connection acc. to VBG4

not required

3NY7101

3NY7121

3NY7131

Auxiliary contact,
1 changeover contact
normal version
electronics-compatible
Quick retaining plate
to mount the disconnectors
between two mounting rails
(125 mm clearance)

3NY3035
3NY3030

3NY3035
3NY3030

3NY3035
3NY3030

3NY3035
3NY3030

3NY1995

3NY1995

3NY7322

3-phase busbars
for 2 disconnectors
for 3 disconnectors
for 4 disconnectors
connecting buses
for > 4 disconnectors
cap for empty location (20x units):
Incoming supply terminal
(1 set = 3 units) for conductors e/m: up to 95 mm2
finely stranded with end
sleeves: up to 70 mm2

Masking frames
for mounting in general
distribution systems
for disconnectors with
SIGUT terminal
for disconnectors with
flat pad connection
Dimensions (H x W):
Overreach protection
(10 units)

The circuit-breaker is connected in parallel to the


three main disconnector phases, and is tripped as
soon as at least one of three fuses blows. The voltage
is tapped at the handle lugs of the fuses which means
that only fuses with live grip lugs can be used.

not required
break-off

3NY7381
not required

3NY7381
not required

not possible
not required

3NY7102

3NY7102

3NY7105

3NY1237
3NY1238
3NY1438

3NY1263
3NY1265

3NY1236

integrated

integrated

3NY7482

3NY7482

3NY7482

3NY1251

3NY7200

215 x 130

3NY7201
215 x 130

3NY7220
375 x 220

3NY7230
375 x 245

3NY7240
375 x 290

integrated

integrated

3NY7481

3NY7481

3NY7481

 for spare parts, refer to Catalog NSK, Section 12


 for masking frames and mounting sets for 8HP molded-plastic distribution systems, refer to Catalog
E20001-8ZX1012-OHP54-5AB1

This button prevents the shock protection from


being inserted as long as the latching mechanism
hasnt correctly latched into place.

Allaround safety
With the cable lug covers correctly
mounted, the enclosed disconnectors offer a high IP
30 degree of protection, even after a voltage test
using the 6 test holes in the withdrawable fuse carrier. The versions with SIGUT terminals are completely
safe from finger touch without any additional covers.
The large clear inspection window allows the type
and the operating statuses of the fuse links to be
quickly and reliably identified. Overreach and reacharound touch protection is already integrated into
the withdrawable fuse carrier up to 160 A; from
Size 1 shock protection is available as accessory.
At home on all busbars
All 3NP4 sizes are available for 40 mm or 60 mm
busbar center clearance. Busbars can either be 5 or
10 mm wide. For 10 mm busbars, for sizes 000 and
00, two lugs must be broken off at the three rear
busbar clamps. Busbar compensation is available
as accessory for mounting sizes 1 and 2 onto 5 mm
busbars (size 3 disconnectors cannot only be
snapped onto 5 mm busbars).

Quickly mounted
All of these features reduce valuable mounting
and installation time. It also means that the correct
tightening torque of the screws doesnt have to be
checked and adjusted. The mounting rail latching
mechanisms, integrated into the basic size 000 and
00 devices, also provide a clear financial benefit,
especially, where up to 160 A disconnectors are used
in larger unit quantities: additional screws, hooks,
intermediate plates or a second mounting rail are
not required.
Smart accessories for every
application
The auxiliary contacts, which fit all sizes, can be
subsequently retrofitted without taking up any
extra space.
The three-way terminal makes it easy to connect
up to 3 cables (e. g. for capacitor protection).
Several disconnectors can be fed in parallel using
the 3-phase busbars, connecting buses and feeder
terminals up to 225 A. Numerous masking frames
and mounting sets for SIKUS distribution boards or
the 8HP distribution system guarantee simple engineering and fast mounting and installation.

3NP Fuse Switch Disconnector


the Optimum Handle on Every Application

1NO/1NC signal outputs are used as standard. For


size 00, they are brought out to a connector socket
at the front, and for sizes 1 to 3, as double AMP flat
connector at the shock protection in the lower section
of the disconnector.
Either pre-assembled 1- or 3-m cables with strain
relief can be used as connecting cable for size 00.
These can then be easily inserted at the fuse monitoring using the mounted connectors. There are also
connector mounting sets for crimping (short-circuit
proof) cables.

3NP4 quickly mounted onto all busbars

Fuse links, size 000


21 mm wide, Duty class gL/gC
400 V/125 A
3NY1822
400 V/160 A
3NY1824
Sealing pin
can be retrofitted
(1 pkg. = 10 units)

can frequently occur, e. g. in line supplies with AC


drive converters and inverters.

Intelligent latching mechanism


This automatically adapts itself to busbar widths
between 5 and 30 mm, and it reliably latches into
place. This eliminates numerous versions and
complicated adjustments before mounting. There
is a small red button inside the switch, which,
especially from size 1, ensures that the disconnector
is really mounted onto the busbar to its endstop.

3NY7141

3NY3035
3NY3030

Busbar width compensation


only for 5 mm busbars
not required
for 10 mm busbars
break-off
Three-way terminal
(1 set = 3 units) to connect
3 x 2.5 16 mm2 (e/m) or
3 x 2.5 10 mm2 (finely
stranded with end sleeves)
for mounting onto a
SIGUT terminal
for mounting onto a
flat pad connection

for 3NP44
Size 3

Fuse monitoring for 3NP4

From size NH00 onwards, all of the 3NP4 versions are


also available with fuse monitoring. This is realized
using 3RV SIRIUS circuit-breakers which are mounted
at the front in the center of the fuse carrier.

Flat connectors are always used for sizes 13.

The disconnector can then be fed as required from


either the top or the bottom, whereby voltages up to
690 V AC/220 V DC are possible. Furthermore, this
type of fuse monitoring is completely insensitive to
EMC disturbances and harmonics. These disturbances

The function of the 3RV can be tested at any time


using the test button provided.

Technical data
Type
Rated operational voltage Ue

3NP401
AC 50/60 Hz V
DC V

3NP40 7

3NP42

3NP43

3NP44

690
690
220 (3 phases in series)
440 (2 phases in series)
with mounted fuse monitoring upt to 220 V DC max.

Rated conditional short-circuit current with fuses


(for fast closing)
With fuse links
rated current
Size/A
For 400 V AC (690 V)
kA (RMS value)
Permissible fuse cut-off current
kA (peak value)

000/100 (35) 00/160


50 (50)
50
11 (5)
15

1/250
50
25

2/400
50
35

3/630
50
55

Short-circuit strength with fuse


(with the disconnector closed)
With fuse links
rated current
Size/A
Up to 690 V
kA (RMS value)
Permissible fuse cut-off current
kA (peak value)

000/100
100
15

00/160
50
15

1/250
50
25

2/400
50
35

3/630
50
55

Rated operational current and switching capacity


(supply from either the top or bottom)
For 400 V AC, with fuse links or isolating links
Size
Rated breaking current Ic (cos p = 0.35) A (RMS value)
Rated operating current Ie for AC-21B, AC-22B
A
AC-23B
A

000
800
160
100

00
800
160
100

1
2,000
250
250

2
3,200
400
400

3
5,040
630
630

For 690 V AC, with fuse links or isolating links


Size
Rated breaking current Ic (cos p = 0.35) A (RMS value)
Rated operating current Ie for AC-21B
A
AC-22B
A
AC-23B
A

000
240
160
50
25

00
240
160
50
25

1
375
250

2
600
400

3
945
630

 for additional values, refer to Catalog NSK, Section 12 (e. g. capacitor and DC switching capacity, switching capacity
at 500 V AC, ...)

sentric

can also be safely handled, favorably-priced backup protection, simple selectivity calculations and absolute reliability, even when short-circuits occur. The fuse

3NP5 the rugged types for


the toughest applications

melts completely so that there is no residual risk as a result of contacts which


may have welded together. When the disconnector is in the open position,

Furthermore, 3NP5 have an extremely high AC-23


switching capacity. The switching gases which are
formed are deflected into the disconnector using a
sophisticated arc chamber design, instead of being
discharged upwards and to the side. This means
that operating personnel and plant sections and
components in the vicinity are reliably protected.

there is a visible isolating gap, which is often demanded, e. g. for maintenance


purposes. And the optional mounted fuse monitoring offers additional security
fuse switch disconnectors 3NP for the highest plant availability and safety.

Fuse monitoring:
To allow monitoring of the fuses in the disconnectors,
a permanently wired 3RV1 circuit-breaker is mounted
on the fuse carrier.

Fuses for your safety


3NP4 and 3NP5 switch disconnectors
ble to use other disconnectors available on the market. But the fast closing and arc deflection chambers
of the 3NP5 come through with flying colors. 3NP5
provides the highest degree of safety for operating
personnel and the plant, as main switch with high
switching frequency and good AC-23 characteristics,
e.g. for motor loads.
Both of these ranges are climate-proof and correspond to IEC 60 947-3 and VDE 0660, Part 107.
The fuses can be clearly identified through the large
clear inspection window.
Matching masking frames and complete, TSK-tested
mounting sets are available both for the moldedplastic 8HP distribution system as well as for the
various SIKUS distribution boards.
2 series in the range the optimum handle on
every application
The 3NP4 series (sizes NH000 to NH3) offer the
optimum solution for most applications. These range
from power distribution in residential and commercial buildings, through flexible distribution stations
up to power distribution systems in large industrial
plants.They are also admirably suited as main and
incoming feeder breakers in industry, for control
systems, as well as in motor feeders or as backup
protection for circuit-breakers. They have an integrated
lug for sealing which is integrated as standard.
This means that they can be used, without any
restrictions, in meter cabinets and incoming main
feeder boxes for buildings.
The rugged 3NP5 series (sizes NH00 to NH3)
provide reliable protection for all of the tougher
applications. This is especially true in mining, in the
steel industry, and also in the chemical industry,
where sulphur-laden, or aggressive ambient conditions or hazardous locations make it almost impossi-

The values for switching capacitors (e.g. for reactive


power compensation) were also tested (refer to
Catalog NSK, Section 12), and when used with SITOR
semiconductor or 3NE1 double-protection fuses,
3NP disconnectors can be used to protect soft starters,
AC drive converters and similar devices (tables with
tested device-fuse combinations are provided in the
NSK). Shock and vibration testing as well as special
earthquake tests guarantee that the 3NP can be used
in marine applications, nuclear power stations and
similar safety-critical plants.

high switching frequency for devices such as these.


The erosion electrodes additionally extend the lifetime of the main contacts. The lateral spring mechanism (= fast switching) eliminates any danger as
a result of incorrect operation, e.g. briefly actuating
the disconnector or switching which is too slow.

When the switch disconnector is in the ON position,


the circuit-braker poles are connected in parallel
with the fuses to be monitored. When the switch is
in the OFF position, the poles of the circuit-breaker
are dead.
The 3NP5 disconnector series (sizes NH00 to NH3)
for fixed installation can be quickly hung onto preinstalled mounting bolts. They can also be mounted
on the front of switchgear panels using the matching mounting sets or they can be mounted onto
60 mm busbar systems using 8US1 adapters.
The especially rugged design of this series (plastic
with a high resistance to heat, metal parts which can
be mechanically stressed), permits an unusually

The internal resistance of the circuit-breaker is so


high that it does not affect the protection given by
the monitored fuses.

Rated operational voltage Ue

Electronic fuse monitoring (EFM):


The electronic fuse monitoring system is also
mounted on the fuse carrier of the 3NP5. It works
whether or not a load is present. Fuse blowing can
be signalled to a switch control room by means of a
group indication (2NO contacts + 1NC contact).

For surface mounting and switchboard install. in mm

Auxiliary contacts

160 A

without
1NO/1NC
without
1NO/1NC
without
1NO/1NC
without
1NO/1NC
without
1NO/1NC
without
1NO/1NC

250 A

Size 00

Size 1

Flat pad connection

2.5 120

Clamp connection

2.5 50

Flat pad connection


Clamp connection

Short-circuit strength with fuse


(with the disconnector closed)
With fuse links
rated current
Size/A
For 500 V AC
kA (RMS value)
Permissible fuse cut-off current
kA (peak value)
Rated operating current and switching capacity
(supply from either the top or bottom)
For 400 V AC, with fuse links or isolating links
Size
Rated breaking current Ic (cos p = 0.35)
A (RMS value)
Rated operating current Ie for AC-21B up to AC-23B
A
For 690 V AC, with fuse links or isolating links
Size
Rated breaking current Ic (cos p = 0.35)
A (RMS value)
Rated operating current Ie for AC-21B, AC-22B
A
AC-23B
A

35 120

400 A

Size 2

Flat pad connection

6 240

630 A

Size 3

Flat pad connection

6 2 x 240

160 A

Size 00

in mm2

Auxiliary contacts

Flat pad connection


at the bottom

2.5 120

Clamp connection
at the bottom

2.5 50

without
1NO/1NC
without
1NO/1NC

3NP5065 1CF00
3NP5065 1CF10
3NP5065 1CG00
3NP5065 1CG10

400 690 V AC, 220 V DC

For surface mounting and switchboard install. in mm2

Auxiliary contacts2)

160 A

Size 00

Flat pad connection


Clamp connection

2.5 120
2.5 50

1NO/1NC
1NO/1NC

3NP5060 0EA86
3NP5060 0EB86

3NP54

250 A

Size 1

Flat pad connection


Clamp connection

6 150
35 120

1NO/1NC
1NO/1NC

3NP5260 0EA86
3NP5260 0EB86

690
440 (3 phases in series)
220 (2 phases in series with mounted fuse monitoring)

400 A
630 A

Size 2
Size 3

Flat pad connection


Flat pad connection

1NO/1NC
1NO/1NC

3NP5360 0EA86
3NP5460 0EA86

3NP52

3NP53

1)

Rated conditional short-circuit current with fuses


With fuse links
rated current
Size/A
For 500 V AC
kA (RMS value)
Permissible fuse cut-off current
kA (peak value)

6 150

3NP5060 0CA00
3NP5060 0CA00
3NP5060 0CB00
3NP5060 0CB10
3NP5260 0CA00
3NP5260 0CA10
3NP5260 0CB00
3NP5260 0CB10
3NP5360 0CA00
3NP5360 0CA10
3NP5460 0CA00
3NP5460 0CA10

With fuse monitoring

3NP50
50/60 Hz V AC
V DC

Basic versions

For 40 mm busbars1)

Technical data
Type

Selection and ordering data


3NP5 high end series

For 40 mm busbars
00/160
50
15

00/160
100
23

00
1,600
160
00
800
160
100

1/250 2/400 3/630


50
50
50
25
40
50

160 A

 for additional values refer to Catalog NSK, Section 12


(e. g. capacitor and DC switching capacity, switching capacity at 500 V AC, )

0
1,600
160
0
1,000
160
125

2
4,000
400
2
2,520
400
315

Flat pad connection


at the bottom
Clamp connection
at the bottom

Auxiliary contacts

2.5 120

1NO/1NC

3NP5065 1EF86

2.5 50

1NO/1NC

3NP5065 1EG86

400/500 V AC
2

1
2,500
250
1
1,600
250
200

3
5,040
630
3
3,200
630
400

2
4,000
400
2
2,520
400
315

2)

in mm

With electronic fuse monitoring

1/250 2/400 3/630


100
50
50
32
40
60

1
2,500
250
1
1,280
250
160

Size 00

6 240
6 2 x 240

For surface mounting and switchboard install. in mm

Auxiliary contacts

160 A

Size 00

Flat pad connection


Clamp connection

1NO/1NC
1NO/1NC

3NP5060 0HA13
3NP5060 0HB13

250 A
400 A
630 A

Size 1
Size 2
Size 3

Flat pad connection


Flat pad connection
Flat pad connection

1NO/1NC
1NO/1NC
1NO/1NC

3NP5260 0HA13
3NP5360 0HA13
3NP5460 0HA13

For 40 mm busbars1)
160 A

Size 00 at

Flat pad connection


the bottom

2.5 120
2.5 50
6 150
6 240
6 2 x 240
in mm2

Auxiliary contacts

2.5 120

1NO/1NC

3NP5065 1HF13

1) for mounting on 60 mm busbars, use devices for surface mounting and installation and 8US1 busbar adapters
2) optionally, 2 NO as signal outputs: Order No. 3NP5.E.26

3NP5 high end series Accessories


Accessories
for 3NP50
Size 00

for 3NP52
Size 1

for 3NP53
Size 2

for 3NP54
Size 3

Clamp connection
(1 set = 3 units)

3NY1903
2.5 50 mm2

3NY1907
35 120 mm2

Quick retaining plate


between 2 mounting
rails

3NY1995

Adapter
for mounting
on 60 mm
busbars

8US1291-4SB00

8US1210-4AG00

8US1210-4AG00

8US1210-4AG00

3NY1105
215 x 135

3NY1115
215 x 135

3NY1107
265 x 135

3NY1208
250 x 149

3NY1210
300 x 220

3NY1211
300 x 245

3NY1212
300 x 290

3NY1106
290 x 135

3NY1116
290 x 135

3NY1108

3NY1241

3NY1245

3NY1245

Auxiliary contacts
1NO/1NC
(= mounting set)

3NY3033

3NY3034

3NY3034

3NY3034

Sealing lug
can be retrofitted
(1 pkg. = 10 units)

3NY1940

Molded-plastic
masking frames
Dimensions (H x W):
for disconnectors
without/with auxiliary
contacts
Dimensions (H x W):
for disconnectors
with auxiliary contacts
Dimensions (H x W):
Masking frame
mounting set
Dimensions (H x W):
for mounting the disconnector in the front of
the switchgear panel
(masking frame and
mounting parts)
Cable lug cover
Masking frame (H x W)
for disconnectors without/
with auxiliary contacts
Masking frame (H x W)
for disconnectors
with auxiliary contacts
2 separate covers for
top/bottom
6 individual covers
(L = 120 mm)

 for spare parts, refer to Catalog NSK, Section 12


 for masking frames and mounting sets for 8HP molded-plastic distribution systems, refer to Catalog
8ZX1012-OHP54-5AB1
 for masking frames and mounting sets for SIKUS installation distribution panels, refer to Catalogs
I2.34 and 12.35

Subject to change without prior notice 08/02 | Bestell-Nr. EXXXXX-A190-PXXX | DISPO XXXXX | XXXXXXXXX PDWL.XX.X.XX WS 0802X.X | Printed in Germany

Fuses for overload and short-circuit protection means: high short-circuit currents

Siemens AG
Automation and Drives
Low Voltage Controls and Distribution
P. O. Box 32 40, D-91050 Erlangen
www.siemens.com/sentric

S-ar putea să vă placă și