Sunteți pe pagina 1din 36

N OTHI N G LE SS. N OT H I N G E LSE .

NothingLess.NothingElse.
ThinkinverterACs. ThinkDaikin.

100% copper coils in all models

Contents
About Daikin and Daikin India

01

Inverter technology

02

R-32, a next-generation refrigerant

06

Product line up

08

Unit options

28

Feature list

30

About DAIKIN
Daikin is a leading innovator and
provider of advanced, high-quality
air-conditioning solutions for residential,
commercial and industrial applications.
As Worlds No. 1 Air-conditioning
Company, Daikin is committed to
delivering air-conditioning solutions that
enhance the quality of life all around
the world. A diverse multinational
company, Daikin Industries Ltd., active
in air-conditioning, chemicals and oil
hydraulics, was established in 1924.
With headquarters at Osaka, Japan,
the Daikin family has more than
51,000 members, working across
60 production base units and 208
consolidated subsidiaries worldwide.
As the worlds sole manufacturer that
develops a long line of products, from
refrigerants to air-conditioners, Daikin
advocates comfortable living on the
strength of advanced technologies.
Daikin is present in USA and Canada,
Europe and Russia, Middle East, Africa,
Central Asia, Southeast Asia, Oceania
and Latin America. We aim to serve
our customers in each of these markets
by providing optimal air-conditioning
products.

Worlds No.

Daikin India at a glance


2000: Daikin enters the Indian market
in a JV with Usha Shriram Group at
80:20 stakes respectively as Daikin
Shriram Airconditioning.
2002: Daikin introduces VRV
technology in India.
2004: Daikin India becomes a wholly
owned subsidiary of Daikin Industries
Ltd., Japan.
2007: Daikin India relocates HQ to
Gurgaon and commences business of
McQuay chillers in India.
2008: Groundbreaking ceremony of
Daikin Indias manufacturing base at
Neemrana, Rajasthan.
2009: Production commences at
manufacturing plant in Neemrana,
Rajasthan.
2010: Fresh round of Rs. 250 crore
investment. Thus taking it to a total of
Rs. 743 crore.
2012: Production of High Wall Split
air-conditioners with R-32 refrigerant
commences.
2013: Fresh round of Rs. 330 crore
investment.

11
2

10

9
3

12

13
5
6

1. USA 2. Canada 3. Latin America 4. East Asia 5. Southeast Asia 6. Oceania


7. Africa 8. Central Asia 9. Middle East 10. Europe 11. Russia 12. Japan 13. India

What is Inverter Technology and how is it


different from Non-Inverter Technology?
An inverter is a device for
converting frequency. The
technology is used in many home
appliances and controls electric
voltage, current and frequency.
Inverter air-conditioners vary
their cooling/heating capacity
by adjusting the power supply
frequency of their compressors.
An Inverter Type Air-Conditioner
adjusts the speed of the
compressor to control the gas

Inverter
Technology

flow rate, thereby consuming less


current and power. An inverter has
precise temperature control and as
the set temperature is attained, the
unit adjusts its capacity to eliminate
any temperature fluctuations.
In contrast, non-inverter
air-conditioners have a fixed
cooling/heating capacity and can
only control the indoor temperature
by starting or stopping their
compressors.

Non-inverter air-conditioners stops


and starts repeatedly. The power
consumption and current goes
down when the operation stops,
but it goes up sharply at the time
of restart and thus it has high
average power consumption and
temperature variations. As a result,
inverter air-conditioners are more
energy-saving and comfortable
than non-inverter air-conditioners.

Variable capacity operation


Inverter power control

Raise
frequency

High-speed
rotation

High
capacity

Low-speed
rotation

Low
capacity

Compressor

Power
Source
Lower
frequency

Non-inverter type air-conditioner


Power
Source

Compressor

Constant Speed
rotation

Fixed
Capacity

Inverter air-conditioners are able to vary their operating capacity. Non-inverter air-conditioners can only operate at a fixed capacity.

What are the benefits


of Inverter Air-Conditioners?
Powerful

Scenario: Indoor Temperature: 22, Set Temperature: 22


Inverter air-conditioner

Inverter air-conditioners operate


at maximum capacity as soon as
they start up. As a result, the set
temperature can be reached
more quickly.

Energy saving
After the indoor temperature
approaches the set temperature,
inverter control adjusts to low
capacity operation to maintain
this temperature. This makes
inverter models more energy
saving than non-inverter models,
which must repeatedly start or
stop their compressors to maintain
the room temperature.

22

22

22

22

Temperature remains constant

Non-inverter air-conditioner

Comfortable

21

23

Temperature rises and compressor starts again

23
v

Compressor stops

21
v

Inverter air-conditioners finely


adjust capacity according to
changes in the air-conditioning
load and the difference between
the indoor temperature and set
temperature is small. This gives
higher comfort level than the noninverter air-conditioners.

Temperature fluctuates

Compressor stops

Inverter air-conditioners are more comfortable than non-inverter models


Diagrams is used for illustrative purpose only; actual conditions and scenario may vary from the one shown.

DAIKIN AIRCONDITIONING INDIA PVT. LTD. 02/03

Thetechnology
What is DC inverter?

DC motor for fan

Daikin calls an inverter model


that is equipped with a DC motor
as DC inverter. A DC motor
offers higher efficiency than an
AC motor. A DC motor uses the
power of magnets to attract and
repel to generate rotation. A
DC motor that is equipped with
power neodymium magnets, which
enable even greater efficiency, is
called a reluctance DC motor.

The DC motor allows fine rotation


control, which reduces energy
consumption. The motor also provides
improvements in operational efficiency
of up to 40%, compared to AC motor.
These improvements are particularly
noticeable in the low-speed range.

Efficiency of DC motor for fan*


(comparison with a conventional AC motor)

Reluctance DC motor
for compressor
Daikin DC inverter models are equipped
with the reluctance DC motor for
compressor. The reluctance DC motor uses
two different types of torque, neodymium
magnet1 and reluctance torque2. This
motor saves energy by generating more
power with a smaller electric current than
AC or conventional DC motors. Daikins
internally embedded neodymium magnet
generates strong magnetic field and

100

Recipient of Electric Science


Promotion Award (Reluctance DC
motor for compressor)

Efficiency of Reluctance DC motor4

60

90

40
Approx. 40% increase

20

Approx. 20% increase

0
200 300 400 500 600 700 800 900 1000
Motor speed (rpm)
DC motor

Motor efficiency (%)

Efficiency (%)

80

80

70

60

AC motor

*Data is based on studies conducted under controlled


conditions at a Daikin laboratory using Daikin products.

More than 20%

50
0

30

60

90

120

Rotational speed (rps)


Reluctance DC motor
Conventional DC motor
Small load

Large load Low capacity

AC motor
High capacity

high torque resulting in high operational


efficiency with less electricity consumption.
It is more efficient at low frequencies
most commonly used by air-conditioners3
improving efficiency by approximately 20%.

Swing compressor

Swing bush

Refrigerant gas

Thanks to its smooth rotation, the


swing compressor decreases friction
and vibration. It also prevents leakage
of refrigerant gas during compression.
These advantages provide quiet and
efficient operation.

Pulse amplitude
PAM control reduces energy loss by
controlling how often the converter
switches on and off

Integral piston of blade and roller


The swing compressor can reduce operational
vibration and sound because its piston moves
smoothly inside the compressor.

Sine wave

Neodymium magnets are used


in the pink-coloured area.

Reluctance DC motor

Smooth sine wave of the inverters electric


current eliminates pulsation and high harmonic
noise. Highly effective inverter, that can
generate the control signal which is closer to
the sine wave, thus helping in better efficiency.
.

Ferrite magnet

Neodymium magnet

1 A neodymium magnet is approximately 10 times stronger


than a standard ferrite magnet.
2 The torque created by the change in power between the
iron and magnet pads.
3 The frequency range used by air-conditioners during
periods of stable operation. This is the range in which
air-conditioners operate for the longest periods.
4 Data is based on studies conducted under controlled
conditions at a Daikin laboratory using Daikin products.

Daikin was presented 32nd Chairmans


award by the Japan society for the promotion
of the machine industry for swing compressor

DAIKIN AIRCONDITIONING INDIA PVT. LTD. 04/05

R-32, anext
generation
refrigerant
As part of its
commitment to the
environment, Daikin
aims to develop
systems that improve
comfort levels,
while having low
environmental impact.
Refrigerant choice is
a key factor in the
drive to maximise
energy efficiency and
to minimise the global
warming impact of
system.

R-32, a next
generation refrigerant
is the most balanced
refrigerant for use in
both residential and
commercial
air-conditioners.

Environmental impact
~1.6 times more
cooling compared to
R410A

~5% more power


savings compared to
R410A

~30% less refrigerant


charging volume as
compared to R410A
& R22

Better performance at
higher temperature as
compared to R22
(Low Derating)
Data based on studies conducted
under test conditions

R-32 has zero Ozone Depletion


Potential (ODP) and Modified
Global Warming Potential (GWP)
of 472, compared to R-410As
Modified GWP of 2,027. Also
R-32 is a single component
refrigerant, which makes it easy
to recycle. It is because of these
reasons that R-32 offers the lowest
total emissions and best overall
life-cycle climate performance.

Theoretical Modified GWP


2,500

2,500

120
2,090

2,000

100

100

1,500
1,000
675

80

The potential refrigeration capacity


of R-32 is 1.6 times that of R-22 and
R-410A. More specifically the pressure
loss is lower with R-32 than R-22
or R-410A for the same. The liquid
density of R-32 is 10% lower thus the
piping diameter can be smaller. As a
result, the use of charging volume can
be 30% less than R-22 or R-410A.
The use of R-32 in the new Daikin
range offers end-users the opportunity
to benefit from class-leading energy
efficiencies, excellent air quality and
high comfort levels, while lowering
the environmental impact of the
refrigerants.

2,000
70

60
40

500
0

HCFC HFC HFC


22 410A 32

1,810

1,500
1,000
472

500

20

HCFC HFC HFC


22 410A 32

Charging
ratio (%)

GWP

Better performance

2,027

97

1,810

HCFC HFC HFC


22 410A 32

Theoretical
Modifide GWP

HFC32 is the most balanced refrigerant

Ozone

Ozone

Economy

5
4

5
4

HFC32

Ozone

5
4

Safety

Ozone

5
4

Economy

LCCP

Energy

Safety

HFC410A

LCCP

Energy

Economy

2
1

Safety

HFO1234YF

LCCP

Energy

Economy

2
1

Safety

LCCP

Energy

Propane
(HFC290)

DAIKIN AIRCONDITIONING INDIA PVT. LTD. 06/07

FTXR

Series Heat pump

PERFECTION IN
AIR-CONDITIONING

Total comfort - Humidification,


dehumidification, purification
& ventilation

Ton: 0.75, 1.2, 1.5

Model Name
Capacity

Inverter powerful operation


- Boosts cooling/heating
performance

Power Supply
Running Current
Power
Consumption
COP
Indoor Unit
Front Panel Colour
Airflow rate

Cooling breeze operation Comfortable cooling breeze

Mould proof stick - Prevents


buildup of mould, bacteria
and viruses

For the complete feature list please


refer pages 30-31.

Fan Speed
Sound Levels
(H/M/L/SL)
Dimensions (HxWxD)
Machine Weight
Outdoor Unit
Casing colour
Compressor
Sound Levels
(H/SL)
Dimensions (HxWxD)
Machine Weight
Operation range
Max. Piping Length
Max. Height Difference

Cooling
Heating

Indoor Unit
Outdoor Unit
Rated (Min - Max)
Rated (Min - Max)

Cooling
Heating
Cooling
Heating
Cooling
Heating

Rated
Rated
(Min - Max)
Rated

Cooling
Heating
Cooling
Heating

Kw
Kw

FTXR28KVMA
RXR28KVMA
2.77 (1.55~3.60)
3.57 (1.30~5.00)

A
A
W
W
W/W
W/W

3.3-3.2-3.1
4.0-3.9-3.8
570 (250~800)
710 (220~1410)
4.86
5.03
FTXR28KVMA

m/min
cfm
m/min
cfm

11.1
392
12.4
438

dB (A)

39 / 33 / 26 / 23
41 / 35 / 28 / 25

mm
kg
RXR28KVMA
Cooling
Heating
Cooling
Heating

Type
dB (A)
mm
kg
CDB
CWB
m

46/-46/--

IDU Colour: White

FTXR42KVMA
RXR42KVMA
4.20 (1.55~4.60)
5.08 (1.30~5.60)
1 phase, 220-240V, 50Hz
5.4-5.3-5.2
5.9-5.7-5.6
1070 (260~1320)
1170 (220~1600)
3.93
4.34
FTXR42KVMA
White
12.4
438
12.9
455
5 steps, quiet and Automatic
42 / 35 / 27 / 24
42 / 36 / 29 / 26
305 x 890 x 209
14
RXR42KVMA
Ivory White
Hermetically sealed swing type
48/-48/-693 x 795 x 285
48
10C to 43C
-20C to 18C (Humidify -10 to 24)
10
8

Measurement conditions:
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB, 24 CWB; piping length 7.5 m.
2. Heating capacity is based on: indoor temp. 20 CDB; outdoor temp. 7 CDB, 6 CWB; piping length 7.5 m.
3. Sound levels are based on temperature conditions 1. and 2. above with 5m piping length. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.

FTXR50KVMA
RXR50KVMA
4.88 (1.55~5.50)
5.91 (1.30~6.20)
7.2-7.1-7.0
7.3-7.2-7.1
1470 (260~1800)
1490 (230~1770)
3.32
3.97
FTXR50KVMA
13.3
470
14
494
44 / 37 / 29 / 26
44 / 38 / 31 / 28
RXR50KVMA
48/-50/--

FTXG

Series Heat pump

ITS ALL ABOUT DESIGN

Indoor unit quite operation Cools/heats quietly

Ton: 0.75, 1, 1.4

Model Name
Capacity

Comfortable mode - Provides


gentle and comfortable
environment

Power Supply
Running Current
Power Consumption
COP
Indoor Unit
Front Panel Colour
Airflow rate

Cooling
Heating

Indoor Unit
Outdoor Unit
Rated (Min - Max)
Rated (Min - Max)

Cooling
Heating
Cooling
Heating
Cooling
Heating

Rated
Rated
(Min - Max)
Rated

Cooling
Heating

Intelligent eye - Adjusts cooling


according to human presence

Fan Speed
Sound Levels
(H/M/L/SL)
Dimensions (HxWxD)
Machine Weight
Outdoor Unit
Casing colour
Compressor
Sound Levels (H/SL)

Saranet filter - Removes


airborne dust particles for
cleaner air supply

For the complete feature list please


refer pages 30-31.

Dimensions (HxWxD)
Machine Weight
Operation range
Max. Piping Length
Max. Height Difference

Cooling
Heating

Kw
Kw
A
A
W
W
W/W
W/W
m/min
cfm
m/min
cfm
dB (A)
mm
kg

Type
Cooling
Heating
Cooling
Heating

dB (A)
mm
kg
CDB
CWB
m

IDU Colour: Sandblasted Aluminium

FTXG25JV1BA
RXG25K3V1B
2.5 (1.3~3.0)
3.4 (1.3~4.5)

FTXG35JV1BA
RXG35K3V1B
3.5 (1.4~3.8)
4.0 (1.4~5.0)
1phase, 220-240V, 50Hz
3.2-3.0-2.9
5.1-4.8-4.6
4.4-4.2-4.1
5.6-5.3-5.1
560 (350 - 820)
890 (360 - 1220)
780 (320 - 1320)
990 (320 - 1500)
4.46
3.93
4.36
4.04
FTXG25JV1BA
FTXG35JV1BA
Silver
8.8
10.1
311
357
9.6
10.8
339
389
5 steps, quiet and Automatic
38 / 32 / 25 /22
42 / 34 / 26 / 23
39 / 34 / 28 / 25
42 / 36 / 29 / 26
295 x 915 x 155
11
RXG25K3V1B
RXG35K3V1B
Ivory White
Hermetically sealed swing type
46/43
48/44
47/44
48/45
550 x 765 x 285
34
-10C to 46C
-15C to 20C
20
15

FTXG50JV1BA
RXG50K3V1B
5.0 (1.7~5.3)
5.8 (1.7~6.5)
7.2-6.9-6.6
7.4-7.1-6.8
1560 (450 - 1880)
1600 (520 - 2500)
3.21
3.63
FTXG50JV1BA
10.3
364
11.4
402
44 / 40 / 35 / 32
44 / 40 / 35 / 32
RXG50K3V1B

735 x 825 x 300


48
30
20

Measurement conditions:
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB, 24 CWB; piping length 7.5 m.
2. Heating capacity is based on: indoor temp. 20 CDB; outdoor temp. 7 CDB, 6 CWB; piping length 7.5 m.
3. Sound levels are based on temperature conditions 1. and 2. above with 5m piping length. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.

DAIKIN AIRCONDITIONING INDIA PVT. LTD. 08/09

FTXS

Series Heat pump

BEYOND IMAGINATION

Intelligent eye - Senses human


movement for temperature
adjustment

Ton: 0.75, 1, 1.5, 1.8, 2.2

Model Name
Capacity

3D airflow - Circulates a cloud


of cool/warm air right to the
corners of even large spaces

Running Current
Power consumption

Indoor Unit
Front panel Colour
Airflow rate (H)

Sound Levels (H/L/SL)

Rated

Rated
(Min.-Max)

Rated

W/W

Cooling
Heating

m3/min(cfm)

Cooling
Heating

dB (A)

Dimensions (HxWxD)
Machine weight
Outdoor Unit
Casing colour
Compressor

mm
Kg

Type
Cooling
Heating

dB (A)

Cooling
Heating

mm
Kg
CDB
CWB
m
m

Dimensions (HxWxD)
Machine weight
Operation Range
Max. piping length
Max. height difference

For the complete feature list please


refer pages 30-31.

Cooling
Heating
Cooling
Heating
Cooling
Heating

Fan speed

Sound Levels (H/SL)

Inverter powerful operation Faster cooling/heating

Kw
Kw

Power Supply

COP

Indoor unit quiet operation Quiet performance

Cooling
Heating

Indoor Unit
Outdoor Unit
Rated (Min.-Max)
Rated (Min.-Max)

FTXS25EVMA
RXS25EBVMA
2.5 (1.2-3.0)
3.4 (1.2-4.5)

IDU Colour: White

FTXS35EVMA
RXS35EBVMA
3.5 (1.2-3.8)
4.0 (1.2-5.0)

FTXS50FVMA
FTXS60FVMA
RXS50FVMA
RXS60FVMA
5.0 (1.7-6.0)
6.0 (1.7-6.7)
5.8 (1.7-7.7)
7.0 (1.7-8.0)
1 phase, 230 V, 50Hz
3.3
4.7
6.9
8.8
4.1
4.9
7.1
9
600 (300-800)
1,020 (300-1,200) 1,550 (440-2,080) 1,980 (440-2,390)
830 (290-1,340) 1,080 (290-1,550) 1,600 (400-2,530) 2,040 (400-2,810)
4.17
3.43
3.23
3.03
4.10
3.70
3.63
3.43
FTXS25EVMA
FTXS35EVMA
FTXS50FVMA
FTXS60FVMA
White
8.7 (307)
8.9 (314)
14.7(519)
16.2(572)
9.4 (332)
9.7 (342)
16.2 (572)
17.4 (614)
5 steps, quiet and automatic
37 / 25 / 22
38 / 26 / 23
44 / 35 / 32
45 / 36 / 33
37 / 28 / 25
38 / 29 / 26
42 / 33 / 30
44 / 35 / 32
283 x 800 x 195
290 x 1,050 x 238
9
12
RXS25EBVMA
RXS35EBVMA
RXS50FVMA
RXS60FVMA
Ivory White
Hermetically sealed swing type
46 / 43
47 / 44
49 / 46
47 / 44
48 / 45
49 / 46
550 x 765 x 285

735 x 825 x 300
34
48
10 to 46
-15 to 20
-15 to 18
20
30
15
20

Measurement conditions:
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB, 24 CWB; piping length 7.5m.
2. Heating capacity is based on: indoor temp. 20 CDB; outdoor temp. 7 CDB, 6 CWB; piping length 7.5m.
3. Sound levels are based on temperature conditions 1. and 2. above with 5m piping length. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.

FTXS71FVMA
RXS71FVMA
7.1 (2.3-8.5)
8.2 (2.3-10.0)
10.4
11.1
2,360 (570-3,200)
2,520 (520-3,730)
3.01
3.25
FTXS71FVMA
17.4(614)
21.5 (759)
46 / 37 / 34
46 / 37 / 34

RXS71FVMA

52 / 49
52 / 49
770 x 900 x 320
71

FTKM

Series Cooling only

PATH-BREAKING SERIES

Ton: 0.75, 1, 1.5, 1.8, 2.2

Stabiliser free operation - No


extra cost

New smartphone
connectivity feature (optional)

Indoor unit
Outdoor unit

Model name

Coand airflow - Improves


circulation of cold air

Power supply
Power supply intake
Cooling capacity

kW
Btu/h
Rated (min.~max.)

Intelligent eye - Senses human


movement for temperature
adjustment

Titanium apatite
photocatalytic air purifying
filter - Absorbs bacteria and
viruses and eliminates odor

For the complete feature list please


refer pages 30-31.

Power consumption
COP
Operating current
Indoor unit
Panel color
Dimensions (HxWxD)
Weight (Gross)
Airflow rate Dry (Wet)
Operation sound H/M/L/SL
Outdoor unit
Dimensions (HxWxD)
Weight (Gross)
Operation sound (H)
Refrigerant
Piping length

Piping connection
Operation limit

Cooling

W
W/W
A

Cooling

mm
kg
m3/min.
dBA

Cooling

mm
kg
dBA

Charge-less
Max. length
Max. height
Gas/Liquid
Cooling

m
m
m
mm
DB

IDU Colour: White

FTKM25QRV16
RKM25QRV16

FTKM35QRV16
RKM35QRV16

FTKM50QRV16
RKM50QRV16

FTKM60QRV16
RKM60QRV16

FTKM71QRV16
RKM71QV16

1 50Hz 230V
(220-240V)
Outdoor unit
2.5 (1.0~3.2)
8500
(3400~10900)
650 (220~900)
3.85 (4.55~3.56)
3.07
FTKM25QRV16
White
283x800x198
8 (12)
9.6(8.5)
37/33/28/25
RKM25QRV16
550x765x285
29(36)
47
R32
10
20
15
9.5/ 6.4
10~46

1 50Hz 230V
(220-240V)
Outdoor unit
3.5 (1.0~4.0)
11900
(3400~13600)
964 (220~1300)
3.63 (4.55~3.08)
4.55
FTKM35QRV16
White
283x800x198
8 (12)
9.7(8.6)
39/34/29/26
RKM35QRV16
550x765x285
32(38)
48
R32
10
20
15
9.5/ 6.4
10~46

1 50Hz 230V
(220-240V)
Outdoor unit
5.0 (1.0~6.0)
17100
(3400~20500)
1315 (370~1700)
3.8 (2.70~3.52)
5.8
FTKM50QRV16
White
310x1100x239
13 (18)
17.4(14.6)
42/38/35/28
RKM50QRV16
595x845x300
38(46)
47
R32)
10
30
20
12.7 / 6.4
10~46

1 50Hz 230V
(220-240V)
Outdoor unit
6.0 (1.0~7.0)
20500
(3400~23900)
1666 (230~2250)
3.6 (4.35~3.11)
7.4
FTKM60QRV16
White
310x1100x239
13 (18)
18.1(15.1)
45/41/35/30
RKM60QRV16
595x845x300
39 (47)
49
R32
10
30
20
12.7 / 6.4
10~46

1 50Hz 230V
(220-240V)
Outdoor unit
7.1 (2.1~8.0)
24200
(7200~27300)
2220 (530~3300)
3.2 (2.42~3.96)
9.6
FTKM71QRV16
White
310x1100x239
13 (18)
20.4(17.0)
46/42/36/32
RKM71QV16
735x825x300
49 (59)
52
R32
10
30
20
15.9 / 6.4
10~46

Measurement conditions:
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB, 24 CWB; piping length 5m.
2. Sound levels are based on temperature conditions 1 above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.

DAIKIN AIRCONDITIONING INDIA PVT. LTD. 10/11

DTKM

Series Cooling only

PATH-BREAKING SERIES

Ton: 0.75, 1, 1.5, 1.8


New smartphone
connectivity feature (optional)

Stabiliser free operation - No


extra cost
Indoor unit
Outdoor unit

Model name

Power supply

New good sleep off timer Avoids excessive cooling and


enjoy uninterrupted sleep

Cooling capacity

Intelligent eye - Senses human


movement for temperature
adjustment

Power consumption
COP
Operating current
Indoor unit
Panel color
Dimensions (HxWxD)
Weight (Gross)
Airflow rate Dry (Wet)
Operation sound H/M/L/SL
Outdoor unit
Dimensions (HxWxD)
Weight (Gross)
Operation sound (H)
Refrigerant
Piping length

Titanium apatite
photocatalytic air purifying
filter - Absorbs bacteria and
viruses and eliminates odor

For the complete feature list please


refer pages 30-31.

Power supply intake


kW
Btu/h
Rated (min.~max.)

Piping connection
Operation limit

Cooling

W
W/W
A

Cooling

mm
kg
m3/min.
dBA

Cooling

mm
kg
dBA

Charge-less
Max. length
Max. height
Gas/Liquid
Cooling

m
m
m
mm
DB

IDU Colour: White

DTKM25QRV16
RKMD25QRV16

DTKM35QRV16
RKMD35QRV16

DTKM50QRV16
RKMD50QRV16

DTKM60QRV16
RKMD60QRV16

1 50Hz 230V
(220-240V)
Outdoor unit
2.5 (1.0~3.2)
8500
(3400~10900)
650 (220~900)
3.85 (4.55~3.56)
3.07
DTKM25QRV16
White
283x800x198
8 (12)
9.6(8.5)
37/33/28/25
RKMD25QRV16
550x765x285
29(36)
47
R32
10
20
15
9.5/ 6.4
10~46

1 50Hz 230V
(220-240V)
Outdoor unit
3.5 (1.0~4.0)
11900
(3400~13600)
964 (220~1300)
3.63 (4.55~3.08)
4.55
DTKM35QRV16
White
283x800x198
8 (12)
9.7(8.6)
39/34/29/26
RKMD35QRV16
550x765x285
32(38)
48
R32
10
20
15
9.5/ 6.4
10~46

1 50Hz 230V
(220-240V)
Outdoor unit
5.0 (1.0~6.0)
17100
(3400~20500)
1315 (370~1700)
3.8 (2.70~3.52)
5.8
DTKM50QRV16
White
310x1100x239
13 (18)
17.4(14.6)
42/38/35/28
RKMD50QRV16
595x845x300
38(46)
47
R32
10
30
20
12.7 / 6.4
10~46

1 50Hz 230V
(220-240V)
Outdoor unit
6.0 (1.0~7.0)
20500
(3400~23900)
1666 (230~2250)
3.6 (4.35~3.11)
7.4
DTKM60QRV16
White
310x1100x239
13 (18)
18.1(15.1)
45/41/35/30
RKMD60QRV16
595x845x300
39 (47)
49
R32
10
30
20
12.7 / 6.4
10~46

Measurement conditions:
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB, 24 CWB; piping length 5m.
2. Sound levels are based on temperature conditions 1 above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.

ATKM

Series Cooling only

PATH-BREAKING SERIES

Ton: 0.75, 1, 1.5, 1.8


New smartphone
connectivity feature (optional)

Stabiliser free operation - No


extra cost
Indoor unit
Outdoor unit

Model name

Power supply

Coand airflow - Improves


circulation of cold air

Power supply intake


Cooling capacity

kW
Btu/h
Rated (min.~max.)

Intelligent eye - Senses human


movement for temperature
adjustment

Silver particle anti-bacterial


filter - Kills bacteria and
deodorises the air

Power consumption
COP
Operating current
Indoor unit
Panel color
Dimensions (HxWxD)
Weight (Gross)
Airflow rate Dry (Wet)
Operation sound H/M/L/SL
Outdoor unit
Dimensions (HxWxD)
Weight (Gross)
Operation sound (H)
Refrigerant
Piping length

Piping connection
Operation limit

Cooling

W
W/W
A

Cooling

mm
kg
m3/min.
dBA

Cooling

mm
kg
dBA

Charge-less
Max. length
Max. height
Gas/Liquid
Cooling

m
m
m
mm
DB

IDU Colour: White

ATKM25QRV16
RKMA25QRV16

ATKM35QRV16
RKMA35QRV16

ATKM50QRV16
RKMA50QRV16

ATKM60QRV16
RKMA60QRV16

1 50Hz 230V
(220-240V)
Outdoor unit
2.5 (1.0~3.2)
8500
(3400~10900)
650 (220~900)
3.85 (4.55~3.56)
3.07
ATKM25QRV16
White
283x800x198
8 (12)
9.6(8.5)
37/33/28/25
RKMA25QRV16
550x765x285
29(36)
47
R32
10
20
15
9.5/ 6.4
10~46

1 50Hz 230V
(220-240V)
Outdoor unit
3.5 (1.0~4.0)
11900
(3400~13600)
964 (220~1300)
3.63 (4.55~3.08)
4.55
ATKM35QRV16
White
283x800x198
8 (12)
9.7(8.6)
39/34/29/26
RKMA35QRV16
550x765x285
32(38)
48
R32
10
20
15
9.5/ 6.4
10~46

1 50Hz 230V
(220-240V)
Outdoor unit
5.0 (1.0~6.0)
17100
(3400~20500)
1315 (370~1700)
3.8 (2.70~3.52)
5.8
ATKM50QRV16
White
310x1100x239
13 (18)
17.4(14.6)
42/38/35/28
RKMA50QRV16
595x845x300
38(46)
47
R32
10
30
20
12.7 / 6.4
10~46

1 50Hz 230V
(220-240V)
Outdoor unit
6.0 (1.0~7.0)
20500
(3400~23900)
1666 (230~2250)
3.6 (4.35~3.11)
7.4
ATKM60QRV16
White
310x1100x239
13 (18)
18.1(15.1)
45/41/35/30
RKMA60QRV16
595x845x300
39 (47)
49
R32
10
30
20
12.7 / 6.4
10~46

Measurement conditions:
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB, 24 CWB; piping length 5m.
2. Sound levels are based on temperature conditions 1 above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.

For the complete feature list please


refer pages 30-31.

DAIKIN AIRCONDITIONING INDIA PVT. LTD. 12/13

FTKP

Series Cooling only

AIR-CONDITIONING
REDEFINED

Ton: 0.75, 1, 1.5, 1.8, 2.2

Stabiliser free operation - No


extra cost

New smartphone
connectivity feature (optional)

Indoor unit
Outdoor unit

Model name

Coand airflow - Improves


circulation of cold air

Power supply
Power supply intake
Cooling capacity

Power chill operation - Quickly


maximises the cooling

Titanium apatite
photocatalytic air purifying
filter - Absorbs bacteria and
viruses and eliminates odor

For the complete feature list please


refer pages 30-31.

Power consumption
COP
Operating current
Indoor unit
Panel color
Dimensions (HxWxD)
Weight (Gross)
Airflow rate Dry (Wet)
Operation sound H/M/L/SL
Outdoor unit
Dimensions (HxWxD)
Weight (Gross)
Operation sound H/L
Refrigerant
Piping length

Piping connection
Operation limit

Cooling

kW
Btu/h
W
W/W
A

Cooling

mm
kg
m3/min.
dBA

Cooling

mm
kg
dBA

Charge-less
Max. length
Max. height
Gas/Liquid
Cooling

m
m
m
mm
DB

Rated (min.~max.)

FTKP25QRV16
RKP25QRV16

FTKP35QRV16
RKP35QRV16

1 50Hz 230V
1 50Hz 230V
(220-240V)
(220-240V)
Outdoor unit
Outdoor unit
2.5 (1.8~3.2)
3.4 (1.8~4.0)
8500 (6100~10900) 11600 (6100~13600)
723 (475~900)
982 (475~1310)
3.46 (3.79~3.56)
3.46 (3.79~3.05)
3.49
4.74
FTKP25QRV16
FTKP35QRV16
White
White
283x800x198
283x800x198
8 (12)
8 (12)
9.6(8.5)
9.9(8.8)
37/33/28/25
40/36/31/26
RKP25QRV16
RKP35QRV16
550x765x285
550x765x285
29(36)
32(38)
49/-49/-R32
R32
10
10
20
20
15
15
9.5/ 6.4
9.5/ 6.4
19.4~46
19.4~46

FTKP50QRV16
RKP50QRV16
1 50Hz 230V
(220-240V)
Outdoor unit
5.0 (2.5~5.7)
17100 (8500~19400)
1445 (710~1750)
3.46 (3.52~3.26)
6.5
FTKP50QRV16
White
310x1100x239
13 (18)
17.4(14.6)
45/40/35/-RKP50QRV16
595x845x300
41(48)
50/-R32
10
30
20
12.7 / 6.4
19.4~46

Measurement conditions:
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB, 24 CWB; piping length 5m.
2. Sound levels are based on temperature conditions 1 above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.

IDU Colour: White

FTKP60QRV16
RKP60QRV16

FTKP71QRV16
RKP71QRV16

1 50Hz 230V
1 50Hz 230V
(220-240V)
(220-240V)
Outdoor unit
Outdoor unit
6.0 (2.5~6.7)
7.1 (2.1~7.5)
20500 (8500~22900) 24200(7200~25600)
1765 (720~2220)
2365(600~3100)
3.40 (3.47~3.02)
3 (3.50~2.42)
7.8
10.4
FTKP60QRV16
FTKP71QRV16
White
White
310x1100x239
310x1100x239
13 (18)
13 (18)
18.1(15.1)
20.4(17.0)
47/43/38/-47/43/39/-RKP60QRV16
RKP71QRV16
595x845x300
595x845x300
38(46)
39(47)
54/-55/-R32
R32
10
10
30
30
20
20
12.7 / 6.4
15.9/ 6.4
19.4~46
19.4~46

DTKP

Series Cooling only

AIR-CONDITIONING
REDEFINED

Ton: 0.75, 1, 1.5, 1.8, 2.2

Stabiliser free operation - No


extra cost

New smartphone
connectivity feature (optional)

Indoor unit
Outdoor unit

Model name

New good sleep-off timer Avoids excessive cooling and


enjoy uninterrupted sleep

Power chill operation - Quickly


maximises the cooling

Titanium apatite
photocatalytic air purifying
filter - Absorbs bacteria and
viruses and eliminates odor

For the complete feature list please


refer pages 30-31.

Power supply
Power supply intake
Cooling capacity
Power consumption
COP
Operating current
Indoor unit
Panel color
Dimensions (HxWxD)
Weight (Gross)
Airflow rate Dry (Wet)
Operation sound H/M/L/SL
Outdoor unit
Dimensions (HxWxD)
Weight (Gross)
Operation sound H/L
Refrigerant
Piping length

Piping connection
Operation limit

Cooling

kW
Btu/h
W
W/W
A

Cooling

mm
kg
m3/min.
dBA

Cooling

mm
kg
dBA

Charge-less
Max. length
Max. height
Gas/Liquid
Cooling

m
m
m
mm
DB

Rated (min.~max.)

DTKP25QRV16
RKPD25QRV16

DTKP35QRV16
RKPD35QRV16

1 50Hz 230V
1 50Hz 230V
(220-240V)
(220-240V)
Outdoor unit
Outdoor unit
2.5 (1.8~3.2)
3.4 (1.8~4.0)
8500 (6100~10900) 11600 (6100~13600)
723 (475~900)
982 (475~1310)
3.46 (3.79~3.56)
3.46 (3.79~3.05)
3.49
4.74
DTKP25QRV16
DTKP35QRV16
White
White
283x800x198
283x800x198
8 (12)
8 (12)
9.6(8.5)
9.9(8.8)
37/33/28/25
40/36/31/26
RKPD25QRV16
RKPD35QRV16
550x765x285
550x765x285
29(36)
32(38)
49/-49/-R32
R32
10
10
20
20
15
15
9.5/ 6.4
9.5/ 6.4
19.4~46
19.4~46

DTKP50QRV16
RKPD50QRV16
1 50Hz 230V
(220-240V)
Outdoor unit
5.0 (2.5~5.7)
17100 (8500~19400)
1445 (710~1750)
3.46 (3.52~3.26)
6.5
DTKP50QRV16
White
310x1100x239
13 (18)
17.4(14.6)
45/40/35/-RKPD50QRV16
595x845x300
41(48)
50/-R32
10
30
20
12.7 / 6.4
19.4~46

IDU Colour: White

DTKP60QRV16
RKPD60QRV16

DTKP71QRV16
RKPD71QRV16

1 50Hz 230V
1 50Hz 230V
(220-240V)
(220-240V)
Outdoor unit
Outdoor unit
6.0 (2.5~6.7)
7.1 (2.1~7.5)
20500 (8500~22900) 24200(7200~25600)
1765 (720~2220)
2365(600~3100)
3.40 (3.47~3.02)
3 (3.50~2.42)
7.8
10.4
DTKP60QRV16
DTKP71QRV16
White
White
310x1100x239
310x1100x239
13 (18)
13 (18)
18.1(15.1)
20.4(17.0)
47/43/38/-47/43/39/-RKPD60QRV16
RKPD71QRV16
595x845x300
595x845x300
38(46)
39(47)
54/-55/-R32
R32
10
10
30
30
20
20
12.7 / 6.4
15.9/ 6.4
19.4~46
19.4~46

Measurement conditions:
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB, 24 CWB; piping length 5m.
2. Sound levels are based on temperature conditions 1 above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.

DAIKIN AIRCONDITIONING INDIA PVT. LTD. 14/15

ATKP

Series Cooling only

AIR-CONDITIONING
REDEFINED

Ton: 0.75, 1, 1.5, 1.8, 2.2

Stabiliser free operation - No


extra cost

New smartphone
connectivity feature (optional)

Indoor unit
Outdoor unit

Model name

Econo mode - Reduces power


consumption

Power supply
Power supply intake
Cooling capacity

Power chill operation - Quickly


maximises the cooling

Silver particle anti-bacterial


filter - Kills bacteria and
deodorises the air

For the complete feature list please


refer pages 30-31.

Power consumption
COP
Operating current
Indoor unit
Panel color
Dimensions (HxWxD)
Weight (Gross)
Airflow rate Dry (Wet)
Operation sound H/M/L/SL
Outdoor unit
Dimensions (HxWxD)
Weight (Gross)
Operation sound H/L
Refrigerant
Piping length

Piping connection
Operation limit

Cooling

kW
Btu/h
W
W/W
A

Cooling

mm
kg
m3/min.
dBA

Cooling

mm
kg
dBA

Charge-less
Max. length
Max. height
Gas/Liquid
Cooling

m
m
m
mm
DB

Rated (min.~max.)

ATKP25QRV16
RKPA25QRV16

ATKP35QRV16
RKPA35QRV16

1 50Hz 230V
1 50Hz 230V
(220-240V)
(220-240V)
Outdoor unit
Outdoor unit
2.5 (1.8~3.2)
3.4 (1.8~4.0)
8500 (6100~10900) 11600 (6100~13600)
723 (475~900)
982 (475~1310)
3.46 (3.79~3.56)
3.46 (3.79~3.05)
3.49
4.74
ATKP25QRV16
ATKP35QRV16
White
White
283x800x198
283x800x198
8 (12)
8 (12)
9.6(8.5)
9.9(8.8)
37/33/28/25
40/36/31/26
RKPA25QRV16
RKPA35QRV16
550x765x285
550x765x285
29(36)
32(38)
49/-49/-R32
R32
10
10
20
20
15
15
9.5/ 6.4
9.5/ 6.4
19.4~46
19.4~46

ATKP50QRV16
RKPA50QRV16
1 50Hz 230V
(220-240V)
Outdoor unit
5.0 (2.5~5.7)
17100 (8500~19400)
1445 (710~1750)
3.46 (3.52~3.26)
6.5
ATKP50QRV16
White
310x1100x239
13 (18)
17.4(14.6)
45/40/35/-RKPA50QRV16
595x845x300
41(48)
50/-R32
10
30
20
12.7 / 6.4
19.4~46

Measurement conditions:
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB, 24 CWB; piping length 5m.
2. Sound levels are based on temperature conditions 1 above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.

IDU Colour: White

ATKP60QRV16
RKPA60QRV16

ATKP71QRV16
RKPA71QRV16

1 50Hz 230V
1 50Hz 230V
(220-240V)
(220-240V)
Outdoor unit
Outdoor unit
6.0 (2.5~6.7)
7.1 (2.1~7.5)
20500 (8500~22900) 24200(7200~25600)
1765 (720~2220)
2365(600~3100)
3.40 (3.47~3.02)
3 (3.50~2.42)
7.8
10.4
ATKP60QRV16
ATKP71QRV16
White
White
310x1100x239
310x1100x239
13 (18)
13 (18)
18.1(15.1)
20.4(17.0)
47/43/38/-47/43/39/-RKPA60QRV16
RKPA71QRV16
595x845x300
595x845x300
38(46)
39(47)
54/-55/-R32
R32
10
10
30
30
20
20
12.7 / 6.4
15.9/ 6.4
19.4~46
19.4~46

FTKH

Series Cooling only

A NEW AGE OF
AIR-CONDITIONING

Ton: 1.0, 1.5, 1.8

Stabiliser free operation No extra cost

New smartphone
connectivity feature (optional)

Indoor unit
Outdoor unit

Model name
Power supply

Coand airflow - Improves


circulation of cold air

Power chill operation - Quickly


maximises the cooling

Cooling capacity
Rated (min.~max.)
COP
Operating current
Indoor unit
Panel color
Dimensions (HxWxD)
Weight (Gross)
Airflow rate Dry (Wet)
Operation sound H/M/L/SL
Outdoor unit
Dimensions (HxWxD)
Weight (Gross)
Operation sound H/L
Refrigerant
Piping length
Piping connection
Operation limit

Power supply intake

Charge-less
Max. length
Max. height
Gas/Liquid

Cooling

kW
Btu/h
W/W
A

Cooling

mm
kg
m3/min.
dBA

Cooling

mm
kg
dBA

Cooling

m
m
m
mm
DB

IDU Colour: White

FTKH35QRV16
RKH35QRV16

FTKH50QRV16
RKH50QRV16

FTKH60QRV16
RKH60QRV16

1 50Hz 230V
(220-240V)
Outdoor unit
3.5 (1.75~3.5)
12000 (6000~12000)
3.0 (3.5~3.0)
5.1
FTKH35QRV16
White
283x800x198
8 (12)
9.9(8.8)
40/36/31/26
RKH35QRV16
550x765x285
26(33)
51/-R32
10
20
15
9.5/ 6.4
19.4~46

1 50Hz 230V
(220-240V)
Outdoor unit
5.0 (2.5~5.0)
17100 (8550~17100)
3.0 (3.4~3.0)
7.32
FTKH50QRV16
White
310x1100x239
13 (18)
17.4(14.6)
45/40/35/-RKH50QRV16
595x845x300
34 (42)
54/-R32
10
20
10
12.7 / 6.4
19.4~46

1 50Hz 230V
(220-240V)
Outdoor unit
6.0 (3.0~6.0)
20500 (10250~20500)
3.0 (3.4~3.0)
8.83
FTKH60QRV16
White
310x1100x239
13 (18)
18.1(15.1)
47/43/38/-RKH60QRV16
595x845x300
35(43)
56/-R32
10
30
20
12.7 / 6.4
19.4~46

Measurement conditions:
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB, 24 CWB; piping length 5m.
2. Sound levels are based on temperature conditions 1 above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.

Econo mode - Reduces power


consumption

For the complete feature list please


refer pages 30-31.

DAIKIN AIRCONDITIONING INDIA PVT. LTD. 16/17

FTF

Series Cooling only

EXPERIENCE ELEGANCE
IN AIR-CONDITIONING
Stabiliser free operation - No
extra cost

Ton: 1, 1.5, 1.8

Coand airflow - Improves


circulation of cold air

Indoor unit
Outdoor unit

Model name

Power supply
Power supply intake
Cooling capacity

Titanium apatite photocatalytic air


purifying filter - Absorbs bacteria
and viruses and eliminates odor

Good sleep off timer - Avoids


excessive cooling and enjoy
uninterrupted sleep

Upto 50C operating range Cools at high temperature*


*Not applicable for 1.8 ton model

For the complete feature list please


refer pages 30-31.

Power consumption
COP
Operating current
Indoor unit
Panel color
Dimensions (HxWxD)
Weight (Gross)
Airflow rate Dry (Wet)
Operation sound H/M/L
Outdoor unit
Dimensions (HxWxD)
Weight (Gross)
Operation sound (H)
Refrigerant
Piping length

Piping connection
Operation limit

Cooling

kW
Btu/h
W
W/W
A

Cooling

mm
kg
m3/min.
dBA

Cooling

mm
kg
dBA

Cooling

m
m
m
mm
DB

Rated

Charge-less
Max. length
Max. height
Gas/Liquid

Measurement conditions:
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB, 24 CWB; piping length 5m.
2. Sound levels are based on the temperature condition in 1above.These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.

IDU Colour: White

FTF35QRV16
RF35QRV16

FTF50QRV16
RF50QRV16

FTF60QRV16#
RF60QRV16

1 50Hz 230V
(220-240V)
Outdoor unit
3.35
11450
930
3.6
4.3
FTF35QRV16
White
283x800x198
8 (12)
9.7(8.6)
39/35/29
RF35QRV16
550x765x285
33(41)
49
R32
10
20
15
12.7/ 6.4
19.4~50

1 50Hz 230V
(220-240V)
Outdoor unit
5.2
17750
1445
3.6
6.6
FTF50QRV16
White
310x1100x239
13 (18)
18.1 (15.1)
44/41/35
RF50QRV16
595x845x300
44(54)
50
R32
10
20
10
15.9/ 6.4
19.4~50

1 50Hz 230V
(220-240V)
Outdoor unit
6.4
21800
1880
3.4
8.6
FTF60QRV16#
White
310x1100x239
13 (18)
20.4(17.0)
47/41/35
RF60QRV16
595x845x300
45(55)
56
R32
10
20
10
15.9 / 6.4
19.4~46
# 4 Star

DTF

Series Cooling only

EXPERIENCE ELEGANCE
IN AIR-CONDITIONING
Stabiliser free operation - No
extra cost

Ton: 1 1.5, 1.8

Power chill operation - Quickly


maximises the cooling

Indoor unit
Outdoor unit

Model name

Power supply
Power supply intake
Cooling capacity

Titanium apatite photocatalytic air


purifying filter - Absorbs bacteria
and viruses and eliminates odor

Good sleep off timer - Avoids


excessive cooling and enjoy
uninterrupted sleep

Upto 50C operating range Cools at high temperature*


*Not applicable for 1.8 Ton model

For the complete feature list please


refer pages 30-31.

Power consumption
COP
Operating current
Indoor unit
Panel color
Dimensions (HxWxD)
Weight (Gross)
Airflow rate Dry (Wet)
Operation sound H/M/L
Outdoor unit
Dimensions (HxWxD)
Weight (Gross)
Operation sound (H)
Refrigerant
Piping length

Piping connection
Operation limit

Cooling

kW
Btu/h
W
W/W
A

Cooling

mm
kg
m3/min.
dBA

Cooling

mm
kg
dBA

Cooling

m
m
m
mm
DB

Rated

Charge-less
Max. length
Max. height
Gas/Liquid

IDU Colour: White

DTF35QRV16
RFD35QRV16

DTF50QRV16
RFD50QRV16

DTF60QRV16
RFD60QRV16

1 50Hz 230V
(220-240V)
Outdoor unit
3.35
11450
930
3.6
4.3
DTF35QRV16
White
283x800x198
8 (12)
9.7(8.6)
39/35/29
RFD35QRV16
550x765x285
33(41)
49
R32
10
20
15
12.7/ 6.4
19.4~50

1 50Hz 230V
(220-240V)
Outdoor unit
5.2
17750
1445
3.6
6.6
DTF50QRV16
White
310x1100x239
13 (18)
18.1 (15.1)
44/41/35
RFD50QRV16
595x845x300
44(54)
50
R32
10
20
10
15.9/ 6.4
19.4~50

1 50Hz 230V
(220-240V)
Outdoor unit
6.4
21800
1880
3.4
8.6
DTF60QRV16
White
310x1100x239
13 (18)
20.4(17.0)
47/41/35
RFD60QRV16
595x845x300
45(55)
56
R32
10
20
10
15.9 / 6.4
19.4~46

Measurement conditions:
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB, 24 CWB; piping length 5m.
2. Sound levels are based on the temperature condition in 1above.These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.

DAIKIN AIRCONDITIONING INDIA PVT. LTD. 18/19

ATF

Series Cooling only

EXPERIENCE ELEGANCE
IN AIR-CONDITIONING

Stabiliser free operation - No


extra cost

Ton: 1, 1.5, 1.8

Coand airflow - Improves


circulation of cold air

Indoor unit
Outdoor unit

Model name

Power supply
Power supply intake
Cooling capacity

Silver particle anti-bacterial filter Kills bacteria and deodorises


the air

Good sleep off timer - Avoids


excessive cooling and enjoy
uninterrupted sleep

Power consumption
COP
Operating current
Indoor unit
Panel color
Dimensions (HxWxD)
Weight (Gross)
Airflow rate Dry (Wet)
Operation sound H/M/L
Outdoor unit
Dimensions (HxWxD)
Weight (Gross)
Operation sound (H)
Refrigerant
Piping length

Piping connection
Operation limit

Upto 50C operating range Cools at high temperature*


*Not applicable for 1.8 ton model

For the complete feature list please


refer pages 30-31.

Cooling

kW
Btu/h
W
W/W
A

Cooling

mm
kg
m3/min.
dBA

Cooling

mm
kg
dBA

Cooling

m
m
m
mm
DB

Rated

Charge-less
Max. length
Max. height
Gas/Liquid

Measurement conditions:
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB, 24 CWB; piping length 5m.
2. Sound levels are based on the temperature condition in 1above.These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.

IDU Colour: White

ATF35QRV16
RFA35QRV16

ATF50QRV16
RFA50QRV16

ATF60QRV16
RFA60QRV16

1 50Hz 230V
(220-240V)
Outdoor unit
3.35
11450
930
3.6
4.3
ATF35QRV16
White
283x800x198
8 (12)
9.7(8.6)
39/35/29
RFA35QRV16
550x765x285
33(41)
49
R32
10
20
15
12.7/ 6.4
19.4~50

1 50Hz 230V
(220-240V)
Outdoor unit
5.2
17750
1445
3.6
6.6
ATF50QRV16
White
310x1100x239
13 (18)
18.1 (15.1)
44/41/35
RFA50QRV16
595x845x300
44(54)
50
R32
10
20
10
15.9/ 6.4
19.4~50

1 50Hz 230V
(220-240V)
Outdoor unit
6.4
21800
1880
3.4
8.6
ATF60QRV16
White
310x1100x239
13 (18)
20.4(17.0)
47/41/35
RFA60QRV16
595x845x300
45(55)
56
R32
10
20
10
15.9 / 6.4
19.4~46

FTC

Series Cooling only

EXTRA COMFORT,
SUPERIOR COOLING

Stabiliser free operation - No


extra cost

Ton: 0.75, 1.0, 1.5, 1.8

Indoor unit
Outdoor unit

Model name

Coand airflow - Improves


circulation of cold air

Power chill operation - Quickly


maximises the cooling

Econo mode - Reduces power


consumption

Power supply
Power supply intake
Cooling capacity
Power consumption
COP
Operating current
Indoor unit
Panel color
Dimensions (HxWxD)
Weight (Gross)
Airflow rate Dry (Wet)
Operation sound H/M/L
Outdoor unit
Dimensions (HxWxD)
Weight (Gross)
Operation sound (H)
Refrigerant
Piping length

Piping connection
Operation limit

Cooling

kW
Btu/h
W
W/W
A

Cooling

mm
kg
m3/min.
dBA

Cooling

mm
kg
dBA

Cooling

m
m
m
mm
DB

Rated

Charge-less
Max. length
Max. height
Gas/Liquid

IDU Colour: White

FTC25QRV16
RC25QRV16

FTC35QRV16
RC35QRV16

FTC50QRV16
RC50QRV16

FTC60QRV16
RC60QRV16

1 50Hz 230V
(220-240V)
Outdoor unit
2.5
8500
770
3.25
3.4
FTC25QRV16
White
283x800x205
8 (12)
9.7(8.6)
39/35/29
RC25QRV16
550x765x285
28(36)
51
R32
10
20
15
9.5/ 6.4
19.4~46

1 50Hz 230V
(220-240V)
Outdoor unit
3.35
11450
1030
3.25
4.6
FTC35QRV16
White
283x800x205
8 (12)
9.7(8.6)
39/35/29
RC35QRV16
550x765x285
31(39)
51
R32
10
20
15
9.5 / 6.4
19.4~46

1 50Hz 230V
(220-240V)
Outdoor unit
5.22
17800
1605
3.25
7.3
FTC50QRV16
White
310x1100x258
13 (18)
18.1 (15.1)
44/41/35
RC50QRV16
595x845x300
39(49)
54
R32
10
20
10
12.7/ 6.4
19.4~46

1 50Hz 230V
(220-240V)
Outdoor unit
6.4
21800
1970
3.25
9
FTC60QRV16
White
310x1100x258
13 (18)
20.4 (17.0)
47/41/35
RC60QRV16
595x845x300
45(55)
56
R32
10
20
10
12.7/ 6.4
19.4~46

Measurement conditions:
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp.35 CDB, 24 CWB; piping length 5m.
2. Sound levels are based on the temperature condition in 1. above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.

For the complete feature list please


refer pages 30-31.

DAIKIN AIRCONDITIONING INDIA PVT. LTD. 20/21

DTC

Series Cooling only

EXTRA COMFORT,
SUPERIOR COOLING

Stabiliser free operation - No


extra cost

Ton: 0.75, 1.0, 1.5, 1.8

Indoor unit
Outdoor unit

Model name

Econo mode - Reduces power


consumption

Power chill operation - Quickly


maximises the cooling

Good sleep off timer - Avoids


excessive cooling and enjoy
uninterrupted sleep

For the complete feature list please


refer pages 30-31.

Power supply
Power supply intake
Cooling capacity
Power consumption
COP
Operating current
Indoor unit
Panel color
Dimensions (HxWxD)
Weight (Gross)
Airflow rate Dry (Wet)
Operation sound H/M/L
Outdoor unit
Dimensions (HxWxD)
Weight (Gross)
Operation sound (H)
Refrigerant
Piping length

Piping connection
Operation limit

Cooling

kW
Btu/h
W
W/W
A

Cooling

mm
kg
m3/min.
dBA

Cooling

mm
kg
dBA

Cooling

m
m
m
mm
DB

Rated

Charge-less
Max. length
Max. height
Gas/Liquid

IDU Colour: White

DTC25QRV16
RCD25QRV16

DTC35QRV16
RCD35QRV16

DTC50QRV16
RCD50QRV16

DTC60QRV16
RCD60QRV16

1 50Hz 230V
(220-240V)
Outdoor unit
2.5
8500
770
3.25
3.4
DTC25QRV16
White
283x800x205
8 (12)
9.7(8.6)
39/35/29
RCD25QRV16
550x765x285
28(36)
51
R32
10
20
15
9.5/ 6.4
19.4~46

1 50Hz 230V
(220-240V)
Outdoor unit
3.35
11450
1030
3.25
4.6
DTC35QRV16
White
283x800x205
8 (12)
9.7(8.6)
39/35/29
RCD35QRV16
550x765x285
31(39)
51
R32
10
20
15
9.5 / 6.4
19.4~46

1 50Hz 230V
(220-240V)
Outdoor unit
5.22
17800
1605
3.25
7.3
DTC50QRV16
White
310x1100x258
13 (18)
18.1 (15.1)
44/41/35
RCD50QRV16
595x845x300
39(49)
54
R32
10
20
10
12.7/ 6.4
19.4~46

1 50Hz 230V
(220-240V)
Outdoor unit
6.4
21800
1970
3.25
9
DTC60QRV16
White
310x1100x258
13 (18)
20.4 (17.0)
47/41/35
RCD60QRV16
595x845x300
45(55)
56
R32
10
20
10
12.7/ 6.4
19.4~46

Measurement conditions:
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB, 24 CWB; piping length 5m.
2. Sound levels are based on the temperature condition in 1. above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.

ATC

Series Cooling only

EXTRA COMFORT,
SUPERIOR COOLING

Stabiliser free operation - No


extra cost

Ton: 0.75, 1.0, 1.5, 1.8

Indoor unit
Outdoor unit

Model name

Coand airflow - Improves


circulation of cold air

Power chill operation - Quickly


maximises the cooling

Multi function filter - 99%


efficiency against bacteria,
virus and mildew

For the complete feature list please


refer pages 30-31.

Power supply
Power supply intake
Cooling capacity
Power consumption
COP
Operating current
Indoor unit
Panel color
Dimensions (HxWxD)
Weight (Gross)
Airflow rate Dry (Wet) *1
Operation sound H/M/L
Outdoor unit
Dimensions (HxWxD)
Weight (Gross)
Operation sound (H)
Refrigerant
Piping length

Piping connection
Operation limit

Cooling

kW
Btu/h
W
W/W
A

Cooling

mm
kg
m3/min.
dBA

Cooling

mm
kg
dBA

Cooling

m
m
m
mm
DB

Rated

Charge-less
Max. length
Max. height
Gas/Liquid

IDU Colour: White

ATC25QRV16
RCA25QRV16

ATC35QRV16
RCA35QRV16

ATC50QRV16
RCA50QRV16

ATC60QRV16
RCA60QRV16

1 50Hz 230V
(220-240V)
Outdoor unit
2.5
8500
770
3.25
3.4
ATC25QRV16
White
283x800x205
8 (12)
9.7(8.6)
39/35/29
RCA25QRV16
550x765x285
28(36)
51
R32
10
20
15
9.5/ 6.4
19.4~46

1 50Hz 230V
(220-240V)
Outdoor unit
3.35
11450
1030
3.25
4.6
ATC35QRV16
White
283x800x205
8 (12)
9.7(8.6)
39/35/29
RCA35QRV16
550x765x285
31(39)
51
R32
10
20
15
9.5 / 6.4
19.4~46

1 50Hz 230V
(220-240V)
Outdoor unit
5.22
17800
1605
3.25
7.3
ATC50QRV16
White
310x1100x258
13 (18)
18.1 (15.1)
44/41/35
RCA50QRV16
595x845x300
39(49)
54
R32
10
20
10
12.7/ 6.4
19.4~46

1 50Hz 230V
(220-240V)
Outdoor unit
6.4
21800
1970
3.25
9
ATC60QRV16
White
310x1100x258
13 (18)
20.4 (17.0)
47/41/35
RCA60QRV16
595x845x300
45(55)
56
R32
10
20
10
12.7/ 6.4
19.4~46

Measurement conditions:
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB, 24 CWB; piping length 5m.
2. Sound levels are based on the temperature condition in 1. above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.

DAIKIN AIRCONDITIONING INDIA PVT. LTD. 22/23

FTQ

Series Cooling only

EXPERIENCE NIRVANA

Stabiliser free operation - No


extra cost

Ton: 1, 1.5, 1.8

Indoor unit
Outdoor unit

Model name

Coand airflow - Improves


circulation of cold air

Power chill operation - Quickly


maximises the cooling

Good sleep off timer - Avoids


excessive cooling and enjoy
uninterrupted sleep

For the complete feature list please


refer pages 30-31.

Power supply
Power supply intake
Cooling capacity
Power consumption
COP
Operating current
Indoor unit
Panel color
Dimensions (HxWxD)
Weight (Gross)
Airflow rate Dry (Wet)
Operation sound H/M/L
Outdoor unit
Dimensions (HxWxD)
Weight (Gross)
Operation sound (H)
Refrigerant
Piping length

Piping connection
Operation limit

Cooling

kW
Btu/h
W
W/W
A

Cooling

mm
kg
m3/min.
dBA

Cooling

mm
kg
dBA

Cooling

m
m
m
mm
DB

Rated

Charge-less
Max. length
Max. height
Gas/Liquid

Measurement conditions:
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB, 24 CWB; piping length 5m.
2. Sound levels are based on the temperature condition in 1. above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.

IDU Colour: White

FTQ35QRV16
RQ35QRV16

FTQ50QRV16
RQ50QRV16

FTQ60QRV16
RQ60QRV16

1 50Hz 230V
(220-240V)
Outdoor unit
3.35
11450
1100
3.05
4.9
FTQ35QRV16
White
283x800x205
8 (12)
9.7(8.6)
39/35/30
RQ35QRV16
550x765x285
30(38)
51
R32
10
20
15
9.5/ 6.4
19.4~46

1 50Hz 230V
(220-240V)
Outdoor unit
5.2
17750
1705
3.05
7.8
FTQ50QRV16
White
310x1100x258
13 (18)
18.5 (15.4)
45/41/35
RQ50QRV16
595x845x300
36(46)
54
R32
10
20
10
12.7/ 6.4
19.4~46

1 50Hz 230V
(220-240V)
Outdoor unit
6.4
21800
2100
3.05
9.6
FTQ60QRV16
White
310x1100x258
13 (18)
20.4 (17.0)
47/41/35
RQ60QRV16
595x845x300
45/(55)
56
R32
10
20
10
12.7/ 6.4
19.4~46

DTQ

Series Cooling only

EXPERIENCE NIRVANA

Stabiliser free operation - No


extra cost

Ton: 1, 1.5, 1.8

Indoor unit
Outdoor unit

Model name

Econo mode - Reduces power


consumption

Power chill operation - Quickly


maximises the cooling

Good sleep off timer - Avoids


excessive cooling and enjoy
uninterrupted sleep

For the complete feature list please


refer pages 30-31.

Power supply
Power supply intake
Cooling capacity
Power consumption
COP
Operating current
Indoor unit
Panel color
Dimensions (HxWxD)
Weight (Gross)
Airflow rate Dry (Wet)
Operation sound H/M/L
Outdoor unit
Dimensions (HxWxD)
Weight (Gross)
Operation sound (H)
Refrigerant
Piping length

Piping connection
Operation limit

Cooling

kW
Btu/h
W
W/W
A

Cooling

mm
kg
m3/min.
dBA

Cooling

mm
kg
dBA

Cooling

m
m
m
mm
DB

Rated

Charge-less
Max. length
Max. height
Gas/Liquid

IDU Colour: White

DTQ35QRV16
RQD35QRV16

DTQ50QRV16
RQD50QRV16

DTQ60QRV16
RQD60QRV16

1 50Hz 230V
(220-240V)
Outdoor unit
3.35
11450
1100
3.05
4.9
DTQ35QRV16
White
283x800x205
8 (12)
9.7(8.6)
39/35/30
RQD35QRV16
550x765x285
30(38)
51
R32
10
20
15
9.5/ 6.4
19.4~46

1 50Hz 230V
(220-240V)
Outdoor unit
5.2
17750
1705
3.05
7.8
DTQ50QRV16
White
310x1100x258
13 (18)
18.5 (15.4)
45/41/35
RQD50QRV16
595x845x300
36(46)
54
R32
10
20
10
12.7/ 6.4
19.4~46

1 50Hz 230V
(220-240V)
Outdoor unit
6.4
21800
2100
3.05
9.6
DTQ60QRV16
White
310x1100x258
13 (18)
20.4 (17.0)
47/41/35
RQD60QRV16
595x845x300
45/(55)
56
R32
10
20
10
12.7/ 6.4
19.4~46

Measurement conditions:
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB, 24 CWB; piping length 5m.
2. Sound levels are based on the temperature condition in 1. above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.

DAIKIN AIRCONDITIONING INDIA PVT. LTD. 24/25

ATQ

Series Cooling only

EXPERIENCE NIRVANA

Stabiliser free operation - No


extra cost

Ton: 1, 1.5, 1.8

Indoor unit
Outdoor unit

Model name

Econo mode - Reduces power


consumption

Power chill operation - Quickly


maximises the cooling

Good sleep off timer - Avoids


excessive cooling and enjoy
uninterrupted sleep

For the complete feature list please


refer pages 30-31.

Power supply
Power supply intake
Cooling capacity
Power consumption
COP
Operating current
Indoor unit
Panel color
Dimensions (HxWxD)
Weight (Gross)
Airflow rate Dry (Wet)
Operation sound H/M/L
Outdoor unit
Dimensions (HxWxD)
Weight (Gross)
Operation sound (H)
Refrigerant
Piping length

Piping connection
Operation limit

Cooling

kW
Btu/h
W
W/W
A

Cooling

mm
kg
m3/min.
dBA

Cooling

mm
kg
dBA

Cooling

m
m
m
mm
DB

Rated

Charge-less
Max. length
Max. height
Gas/Liquid

Measurement conditions:
1. Cooling capacity is based on: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB, 24 CWB; piping length 5m.
2. Sound levels are based on the temperature condition in 1. above. These are anechoic conversion values. These values are normally somewhat higher during actual operation as a result of ambient conditions.

IDU Colour: White

ATQ35QRV16
RQA35QRV16

ATQ50QRV16
RQA50QRV16

ATQ60QRV16
RQA60QRV16

1 50Hz 230V
(220-240V)
Outdoor unit
3.35
11450
1100
3.05
4.9
ATQ35QRV16
White
283x800x205
8 (12)
9.7(8.6)
39/35/30
RQA35QRV16
550x765x285
30(38)
51
R32
10
20
15
9.5/ 6.4
19.4~46

1 50Hz 230V
(220-240V)
Outdoor unit
5.2
17750
1705
3.05
7.8
ATQ50QRV16
White
310x1100x258
13 (18)
18.5 (15.4)
45/41/35
RQA50QRV16
595x845x300
36(46)
54
R32
10
20
10
12.7/ 6.4
19.4~46

1 50Hz 230V
(220-240V)
Outdoor unit
6.4
21800
2100
3.05
9.6
ATQ60QRV16
White
310x1100x258
13 (18)
20.4 (17.0)
47/41/35
RQA60QRV16
595x845x300
45/(55)
56
R32
10
20
10
12.7/ 6.4
19.4~46

FTYN

Series Heat pump

FOR ALL SEASONS

Saranet filter - Clean air


supply

Ton: 1, 1.5, 1.8

Model Name
Capacity

Programme dry function Reduces humidity

Power Supply
Running Current
Power Consumption
COP
Indoor Unit
Front Panel Colour
Airflow rate (T/H/M/L/Q)

Self diagnosis - Digital display for


easy maintenance

Fan Speed
Sound Levels (T/H/M/L/Q)
Dimensions (HxWxD)
Machine Weight
Outdoor Unit
Casing colour
Compressor
Sound Levels
Dimensions (HxWxD)
Machine Weight
Operation range

Hot start - Prevents cold


draughts

Max. Piping Length


Max. Height Difference

Indoor Unit
Outdoor Unit

FTYN35JXV1
RYN35CJXV1

FTYN50JXV1
RYN50CJXV1

FTYN60JXV1
RYN60CJXV1

5.25
5.28
1 phase, 220-240V, 50Hz
7.19
6.53
1,635
1,490

6.01
6.15

Cooling
Heating

Kw
Kw

3.15
3.38

Cooling
Heating
Cooling
Heating
Cooling
Heating

A
A
W
W
W/W
W/W

5.10
4.70
1,094
988
2.88
3.42
FTYN35JXV1

Cooling

m/min
cfm

10.5 / 10.1 / 8.4 / 6.9 / 6.4


372 / 355 / 298 / 242 / 225

dB (A)
mm
kg

41 / 40 / 35 / 29 / 28
288 x 800 x 206

Cooling

9
RYN35CJXV1

Type
Cooling
Cooling
Heating

dBA
mm
kg
CDB
CWB
m

IDU Colour: White

49
540 x 700 x 250
31

12
5

8.26
7.99
1,870
1,800

3.21
3.54
3.42
FTYN50JXV1
FTYN60JXV1
White
16.1 / 15.2 / 13.5 / 12.0 / 10.6 18.2 / 17.4 / 15.2 / 13.4 / 11.8
570 / 536 / 478 / 424 / 375
641 / 614 / 537 / 474 / 418
3 steps, Turbo and Quiet
44 / 42 / 39 / 36 / 34
48 / 46 / 43 / 40 / 37
310 x 1065 x 224
14
RYN50CJXV1
Light Grey
Rotary
52
651 x 855 x 328
47
19C to 46C
-9C to 18C

RYN60CJXV1
52
753 x 855 x 328
50

20
15

Measurement conditions:
1. Cooling: indoor temp. 27 CDB, 19 CWB; outdoor temp. 35 CDB, 24 CWB
2. Heating: indoor temp. 20 CDB; outdoor temp. 7 CDB, 6 CWB
3. All units are being tested and comply to ISO 5151 (Non-ducted unit).

For the complete feature list please


refer pages 30-31.

DAIKIN AIRCONDITIONING INDIA PVT. LTD. 26/27

Unit options
Indoor units
No.
1
2

Item
FTXR28KVMA
FTXR42KVMA
FTXR50KVMA
5-room centralised controller*1
KRC72A
Wiring adaptor for time clock/remote controller*2
KRP413AB1S
(Normal open pulse contact/normal open contact)
3
Air purifying filter set*3
KAF974B42S
4
Air supply filter with frame
KAF963A43
5
Remote controller loss prevention chain
KKF936A4
Notes: *1. A wiring adaptor (KRP413AB1S) is also required for each indoor unit.

*2. Wiring adaptor supplied by DAIKIN. Time clock and other devices should be obtained locally.

*3. A set of a frameless titanium apatite photocatalytic air-purifying filter and a frameless deodorising filter for the streamer discharge unit. Both

filters are standard accessories.

5-room centralised
controller
KRC72A

Air purifying filter set

Air purifying filter set

KAF974B42S

KAF974B42S

Outdoor units
No.
Item
1
Air direction adjustment grille
2
Drain plug*1
3
Humidity hose extension joint*2
4
Humidity hose L cuff*2
5
Humidity hose (10 m)
6
Humidity hose extension set*3
Notes: *1. One set includes 5 pieces for 5 units.

*2. One set includes 10 pieces.

*3. One set includes a 2 m extension hose, 1 joint, and 2 tieraps

RXR28KVMA

RXR42KVMA
KPW937AA4
KKP937A4
KPMJ942A4
KPMH950A4L
KPMH942A42
KPMH942A402

RXR50KVMA

Drain plug

Humidity hose L cuff

KKP937A4

KPMH950A4L

Central remote
controller

Unified on/off
controller

DCS302CA51

DCS301BA51

Humidity hose
extension set

System configurations
No.
Item
FTXR28KVMA
1
Central remote controller*
2
Unified on/off controller*
3
Schedule timer*
4
Interface adaptor for D -NET use
Note: *A wiring adaptor (KRP928BB2S) is also required for each indoor unit.

FTXR42KVMA
DCS302CA51
DCS301BA51
DST301BA51
KRP928BB2S

FTXR50KVMA

Schedule timer
DST301BA51

FTXG series
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
(1)
(2)
(3)
(4)

Item
Wired remote control (3)
Cord for wired remote control
3m
BRCW901A08
8m
Wiring adapter normal open contact / normal open pulse contact
Centralised control board
Up to 5 rooms
Anti-theft protection for remote control
Central remote controller
Unified on/off control
Schedule timer
Interface adapter for DIII-net
Online controller
External mounting kit for online controller
Wifi power cable for online controller
Touch LCD wall controller (4)
Simple wall controller (4)
KNX gateway
Wiring adapter supplied by Daikin. Time clock and other devices: to be purchased locally.
Writing adapter is also required for each indoor unit
Cord for wired remote control BRCW901A03 or BRCW901A08 required.
Can only be used in combination with online controller KKRP01A

FTXG25J

FTXG35J
BRC944
BRCW901A03
KRP413A1S (1)
KRC72 (2)
KKF910A4
DCS302C51
DCS301B51
DST301B51
KRP928A2S
KKR901A
KKRPMO1A
KKRPW01A
KBRC01A
KBRC501A
KLIC-DD

FTXG50J

Indoor units
No.
Item
Indoor
units
Indoor
unitscentralised controller
1
5-room
No.
Item
2
No.
1
1
2
3
2
4
3
3
4
Note:
4
Note:
Note:

FTXS25/35

Wiring
for time
clock/remote controller (normal open pluse contact/normal
Item
5-roomadaptor
centralised
controller
open
5-room
centralised
controller
Wiringcontact)
adaptor
for time
clock/remote controller (normal open pluse contact/normal
Titanium
apatitefor
photocatalytic
air purifying
filter(normal open pluse contact/normal
Wiring
adaptor
time clock/remote
controller
open
contact)
Remote
controller
loss
prevention
chain and
open
contact)
Titanium apatite photocatalytic airfor
purifying
filterholder
Titanium
apatite
photocatalytic
airfor
filterholder
controller
loss
prevention
chain
and
*1.Remote
A wiring
adaptor
(KRP413AB1S)
ispurifying
also
required
for each indoor unit.
Remote
controller
lossother
prevention
chainbe
and
holder locally.
*2.
time
clock and
devicesfor
obtained
*1. The
A wiring
adaptor
(KRP413AB1S)
isshould
also required
for each indoor unit.
*3.
filter
is a standard
accessory.
It also
should
replaced
approximately
*1. The
A wiring
(KRP413AB1S)
required
for each
indoor unit. every 3 years.
*2.
The
time adaptor
clock
and
other
devicesisshould
bebe
obtained
locally.
*2. The
The filter
time clock
and other
devices should
bebe
obtained
*3.
is a standard
accessory.
It should
replacedlocally.
approximately every 3 years.
*3. The filter is a standard accessory. It should be replaced approximately every 3 years.

Outdoor units
No.
Item units
Outdoor
Outdoor
unitsadjustment grille
1
Air
direction
No.
Item
2
No.
1
1
2
2

Drain
plug adjustment grille
Item
Air direction
Air direction
Drain
plug adjustment grille
Drain plug

Control System
No.
ItemSystem
Control
Control
System
1
Central
remote controller
No.
Item

2
Unified
No.
Item
1
Central on/off
remotecontroller
controller
3
Schedule
timercontroller
1
Central on/off
remote
controller
2
Unified
4
Interface
adaptor
for DIII-NET use
2
Unified on/off
3
Schedule
timercontroller
3
Schedule
timer
4
DIII-NET use is also required for each indoor unit.
Notes:
*1.Interface
A wiringadaptor
adaptorfor
(KRP928BB2S)
4
Interface adaptor for DIII-NET use
Notes: *1. A wiring adaptor (KRP928BB2S) is also required for each indoor unit.
Notes: *1. A wiring adaptor (KRP928BB2S) is also required for each indoor unit.

*1
*1
*1
*1
*1
*1
*1

FTXS50/60/71
KRC72 FTXS50/60/71
FTXS25/35
FTXS25/35 KRP413AB1S
KRC72 FTXS50/60/71
KRC72
KRP413AB1S
KAF970A46 KRP413AB1S KAF952B42
KAF970A46 KKF917A4 KAF952B42
KAF970A46 KKF917A4 KAF952B42
KKF917A4

RXS25/35
KPW945A4
RXS25/35
KKP937A4
RXS25/35
KPW945A4
KPW945A4
KKP937A4
KKP937A4

RXS50/60/71
KPW945A4
RXS50/60/71
KKP937A4
RXS50/60/71
KPW945A4
(For
RXS71KPW945A4
KKP937A4
KKP945A4)
KKP937A4
(For
RXS71(For
RXS71KKP945A4)
KKP945A4)

FTXS25/35E

FTXS50/60/71F

FTXS25/35E DCS302CA61
FTXS50/60/71F
DCS301BA61FTXS50/60/71F
FTXS25/35E DCS302CA61
DST301BA61
DCS302CA61
DCS301BA61
KRP928BB2S
DCS301BA61
DST301BA61
DST301BA61
KRP928BB2S
KRP928BB2S

Optional Wi-Fi adaptor kit code for KM, KP, FTKH Series-BRP072A42

Optional Parts

Indoor unit
Indoor unit
Indoor unit

Indoor unit
Indoor unit
Indoor unit

Optional Parts
Optional Parts
Titanium apatite photo catalytic air purifying filter
Ag-ion
(withphoto
frame)catalytic air purifying filter
Titaniumfilter
apatite
Multi-function
filter
Titaniumfilter
apatite
photo
Ag-ion
(with
frame)catalytic air purifying filter
Ag-ion filter (with
Multi-function
filterframe)
Multi-function filter
Optional Parts
Optional Parts
Titanium
Optionalapatite
Parts photo catalytic air purifying filter
Ag-ion
(withphoto
frame)catalytic air purifying filter
Titaniumfilter
apatite
Multi-function
filter
Titaniumfilter
apatite
photo
Ag-ion
(with
frame)catalytic air purifying filter
Ag-ion filter (with
Multi-function
filterframe)
Multi-function filter

5 Star
FTF35QRV16
FTF50QRV16
5 Star
RF35QRV16
RF50QRV16
5 Star
FTF35QRV16
FTF50QRV16
DTF35QRV16
DTF50QRV16
FTF35QRV16
FTF50QRV16
RF35QRV16
RF50QRV16
RFD35QRV16
RFD50QRV16
RF35QRV16
RF50QRV16
DTF35QRV16
DTF50QRV16
Included with the unit DTF50QRV16
in accessories bag
DTF35QRV16
RFD35QRV16
RFD50QRV16
RFD35QRV16
Included with the unit RFD50QRV16
in accessories bag
Included with the unit in accessories bag
5 Star
ATF35QRV16
ATF50QRV16
5 Star
RFA35QRV16
RFA50QRV16
5 Star
ATF35QRV16
ATF50QRV16
ATF35QRV16
ATF50QRV16
RFA35QRV16
RFA50QRV16
Included
with
the
unit
in
accessories
RFA35QRV16
RFA50QRV16 bag
Included with the unit in KAF001A500
accessories bag
Included with the unit in KAF001A500
accessories bag
KAF001A500

FTF60QRV16
RF60QRV16
FTF60QRV16
DTF60QRV16
FTF60QRV16
RF60QRV16
RFD60QRV16
RF60QRV16
DTF60QRV16
DTF60QRV16
RFD60QRV16
RFD60QRV16

FTC25QRV16
RC25QRV16
FTC25QRV16
DTC25QRV16
FTC25QRV16
RC25QRV16
RCD25QRV16
RC25QRV16
DTC25QRV16
DTC25QRV16
RCD25QRV16
RCD25QRV16

ATF60QRV16
RFA60QRV16
ATF60QRV16
ATF60QRV16
RFA60QRV16
RFA60QRV16

ATC25QRV16
RCA25QRV16
ATC25QRV16
ATC25QRV16
RCA25QRV16
RCA25QRV16

Remote Controller
Loss
Prevention
with
Remote
Controller
the
Chain
Remote
Controller
Loss
Prevention
with
Loss
Prevention with
the
Chain
KKF917A4
the Chain
KKF917A4
KKF917A4

5-room Centralised
Controller
5-room Centralised
5-room Centralised
Controller
KRC72
Controller
KRC72
KRC72

Titanium Apatite Photocatalytic


Air-Purifying
FilterPhotocatalytic
Titanium Apatite
Titanium Apatite
Air-Purifying
FilterPhotocatalytic
KAF970A46
Air-Purifying Filter
KAF970A46
KAF970A46
Titanium Apatite Photocatalytic AirPurifying Filter
Titanium
Apatite Photocatalytic AirTitanium
Apatite Photocatalytic AirPurifying
Filter
KAF952B42
Purifying Filter
KAF952B42
KAF952B42

Air Direction Adjustment Grille

Drain Plug

Air
Direction Adjustment Grille
KPW945A4
Air Direction Adjustment Grille
KPW945A4
KPW945A4

Drain
Plug
KKP937A4
Drain Plug
KKP937A4
KKP937A4

Central Remote Controller

Unified On/Off Controller

Schedule Timer

Central
Remote Controller
DCS302CA61
Central Remote Controller
DCS302CA61
DCS302CA61

Unified
On/Off Controller
DCS301BA61
Unified On/Off Controller
DCS301BA61
DCS301BA61

Schedule
Timer
DST301BA61
Schedule Timer
DST301BA61
DST301BA61

3 Star
FTC35QRV16 3 Star
FTC50QRV16
FTC60QRV16
FTQ35QRV16
RC35QRV16
RC50QRV16
RC60QRV16
RQ35QRV16
3 Star
FTC35QRV16
FTC50QRV16
FTC60QRV16
FTQ35QRV16
DTC35QRV16
DTC50QRV16
DTC60QRV16
DTQ35QRV16
FTC35QRV16
FTC50QRV16
FTC60QRV16
FTQ35QRV16
RC35QRV16
RC50QRV16
RC60QRV16
RQ35QRV16
RCD35QRV16
RCD50QRV16
RCD60QRV16
RQD35QRV16
RC35QRV16
RC50QRV16
RC60QRV16
RQ35QRV16
DTC35QRV16
DTC50QRV16
DTC60QRV16
DTQ35QRV16
KAF970A45
DTC35QRV16
DTC50QRV16
DTC60QRV16
DTQ35QRV16
RCD35QRV16
RCD50QRV16
RCD60QRV16
RQD35QRV16
RCD35QRV16KAF057A41
RCD50QRV16
RCD60QRV16
RQD35QRV16
KAF970A45
KAF001A500
KAF970A45
KAF057A41
KAF057A41
KAF001A500
KAF001A500
3 Star
ATC35QRV16 3 Star
ATC50QRV16
ATC60QRV16
ATQ35QRV16
RCA35QRV16 3 Star
RCA50QRV16
RCA60QRV16
RQA35QRV16
ATC35QRV16
ATC50QRV16
ATC60QRV16
ATQ35QRV16
ATC35QRV16
ATC50QRV16
ATC60QRV16
ATQ35QRV16
RCA35QRV16KAF970A45
RCA50QRV16
RCA60QRV16
RQA35QRV16
KAF057A41
RCA35QRV16KAF970A45
RCA50QRV16
RCA60QRV16
RQA35QRV16
Included
with
the
unit
in
accessories
bag
KAF970A45
KAF057A41
KAF057A41
Included with the
unit in accessories bag
Included with the unit in accessories bag

2 Star
FTQ50QRV16
2 Star
RQ50QRV16
2 Star
FTQ50QRV16
DTQ50QRV16
FTQ50QRV16
RQ50QRV16
RQD50QRV16
RQ50QRV16
DTQ50QRV16
DTQ50QRV16
RQD50QRV16
RQD50QRV16

FTQ60QRV16
RQ60QRV16
FTQ60QRV16
DTQ60QRV16
FTQ60QRV16
RQ60QRV16
RQD60QRV16
RQ60QRV16
DTQ60QRV16
DTQ60QRV16
RQD60QRV16
RQD60QRV16

2 Star
ATQ50QRV16
2 Star
RQA50QRV16
2 Star
ATQ50QRV16
ATQ50QRV16
RQA50QRV16
RQA50QRV16

ATQ60QRV16
RQA60QRV16
ATQ60QRV16
ATQ60QRV16
RQA60QRV16
RQA60QRV16

DAIKIN AIRCONDITIONING INDIA PVT. LTD. 28/29


DAIKIN AIRCONDITIONING INDIA PVT. LTD. 28/29
DAIKIN AIRCONDITIONING INDIA PVT. LTD. 28/29

Feature list
Technology
Humidity
control
Comfortable airflow

Comfort
control

Lifestyle
convenience

Cleanliness

Timers

Worry free

Control

Function
Swing compressor and reluctance DC Motor
Rotary compressor
PAM control
Humidifying operation
Drying operation
Dry cooling operation
Moisturising operation
Cooling breeze operation
Comfortable mode
Power-airflow flap
Power-airflow dual flaps
Wide-angle louvres
Vertical auto swing
Horizontal auto swing
3-D airflow
Comfort sleep operation
Hot start
Coanda airflow
Indoor unit quiet operation
Outdoor unit quiet operation
Intelligent eye
Automatic operation (Heating & Cooling)
Programme dry function
Auto fan speed
Temperature and humidity level information display
Econo mode
Home leave operation
Inverter powerful operation
New powerful operation (non-inverter)
Power chill operation
Indoor unit on/off switch
Child lock
Multi-colored indicator
Monitor brightness setting
Fan only
Filter cleaning indicator (on R/C)
Mould shock operation
Home leave ventilation
Streamer discharge air purifier
Mould-proof operation
Mould proof stick
Smell proof operation
Titanium apatite photocatalytic air purifying filter
Air purifying filter
Air intake filter
Silver particle anti-bacterial filter
Saranet filter
Air purifying filter with photocatalytic deodersing function
Fresh air supply ventilation
Multi-function filter
Wipe-clean flat panel
24-Hour on/off timer
Count up-down on/off timer
Weekly timer
Night set mode
Good sleep off timer
New good sleep off timer
Auto restart (after power failure)
Stabiliser free operation
Self-diagnosis
PE anti-corrosion treatment of outdoor heat exchanger
Remote control with backlight
Luminescent remote control buttons
Indoor temperature display on remote control
Remote control LCD back light off
Smartphone connection

FTXR 28/42/50 FTXG 25/35/50 FTXS 25/35 FTXS 50/60/71 FTKM 25/35 FTKM 50/60/71 DTKM 25/35 DTKM 50/60 ATKM 25/35 ATKM 50/60 FTKP 25/35 FTKP 50/60/71 DTKP 25/35 DTKP 50/60/71 ATKP 25/35
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o

o
o

o
o
o

o
o
o
o
o

o
o
o
o
o
o

o
o
o
o
o
o

o
o
o
o
o
o

o
o
o
o
o
o
o
o
o
o
o
o

o
o
o
o
o
o

o
o

o
o
o
o
o
o
o

o
o

o
o
o
o

o
o

o
o
o
o

o
o

o
o
o
o

o
o

o
o
o
o

o
o

o
o
o
o

o
o

o
o
o
o

o
o
o
o

o
o
o

o
o
o

o
o
o
o

o
o
o
o

o
o
o

o
o
o

o
o

o
o

o
o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o
o

o
o
o

o
o
o

o
o
o

o
o
o

o
o
o

o
o
o

o
o
o

o
o
o

o
o
o

o
o
o

o
o

o
o

o
o

o
o

o
Option

o
Option

o
o

o
o

o
o

o
o

o
Option

Option

Option

Option

Option

Option

Option

Option

Option

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o
o
o
o
o

o
o
o
o
o
o

o
o
o
o
o
o

o
o
o
o
o
o

o
o
o
o
o
o

o
o
o
o
o
o

o
o
o
o
o
o

o
o
o
o
o
o

o
o
o
o
o
o

o
o
o
o
o
o

o
o
o
o
o
o

o
o
Option

o
o
Option

o
o
Option

o
o
Option

o
o
Option

o
o
Option

o
o
Option

o
o
Option

o
o
Option

o
o
Option

o
o
Option

o
o
o
o
o
o
o
o

o
o

o
o

o
o

o
o

o
o
o
o
o

o
o
o
o
o

o
o

o
o

Technology
Humidity
control
Comfortable airflow

Comfort
control

Lifestyle
convenience

Cleanliness

Timers

Worry free

Control

Function
ATKP 50/60/71
o
Swing compressor and reluctance DC Motor
Rotary compressor
PAM control
o
Humidifying operation
Drying operation
Dry cooling operation
Moisturising operation
Cooling breeze operation
Comfortable mode
Power-airflow flap
o
Power-airflow dual flaps
Wide-angle louvres
o
Vertical auto swing
o
Horizontal auto swing
o
3-D airflow
o
Comfort sleep operation
Hot start
Coanda airflow
o
o
Indoor unit quiet operation
o
Outdoor unit quiet operation
Intelligent eye
Automatic operation (Heating & Cooling)
Programme dry function
o
Auto fan speed
o
Temperature and humidity level information display
Econo mode
o
Home leave operation
Inverter powerful operation
New powerful operation (non-inverter)
Power chill operation
o
Indoor unit on/off switch
o
Child lock
o
Multi-colored indicator
Monitor brightness setting
Fan only
o
Filter cleaning indicator (on R/C)
Mould shock operation
Home leave ventilation
Streamer discharge air purifier
Mould-proof operation
Mould proof stick
Smell proof operation
o
Titanium apatite photocatalytic air purifying filter
Option
Air purifying filter
Air intake filter
Silver particle anti-bacterial filter
o
Saranet filter
Air purifying filter with photocatalytic deodersing function
Fresh air supply ventilation
Multi-function filter
Wipe-clean flat panel
o
24-Hour on/off timer
o
Count up-down on/off timer
Weekly timer
Night set mode
Good sleep off timer
New good sleep off timer
o
Auto restart (after power failure)
o
Stabiliser free operation
o
Self-diagnosis
o
PE anti-corrosion treatment of outdoor heat exchanger
o
o
Remote control with backlight
Luminescent remote control buttons
Indoor temperature display on remote control
o
Remote control LCD back light off
o
Smartphone connection
Option

FTKH 35 FTKH 50/60 FTF35 FTF50/60 DTF35 DTF50/60 ATF35 ATF50/60 FTC 25/35 FTC50/60 DTC 25/35 DTC50/60 ATC 25/35 ATC50/60 FTQ35 FTQ50/60 DTQ35 DTQ50/60 ATQ35 ATQ50/60 FTYN
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
Option
o

o
Option
o

o
o

o
o

o
o

o
o

o
Option

o
Option

o
Option

o
Option

o
Option

o
Option

o
Option

o
Option

o
Option

o
Option

o
Option

o
Option

o
Option

o
Option

Option

Option

Option

Option

Option

Option

Option

Option

Option

Option

Option

Option

Option

Option

Option

Option

Option

Option

Option
o
o

Option
o
o

Option
o
o

Option
o
o

Option
o
o

Option
o
o

Option
o

Option
o

Option
o

Option
o

o
o

o
o

Option
o

Option
o

Option
o

Option
o

o
o

o
o

o
o
o
o

o
o
o
o

o
o
o
o
o

o
o
o
o
o

o
o
o
o
o

o
o
o
o
o

o
o
o
o
o

o
o
o
o
o

o
o
o
o

o
o
o
o

o
o
o
o

o
o
o
o

o
o
o
o

o
o
o
o

o
o
o
o

o
o
o
o

o
o
o
o

o
o
o
o

o
o
o
o

o
o
o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o

o
o
o
o

Option

Option

DAIKIN AIRCONDITIONING INDIA PVT. LTD. 30/31

o
o

Ten Reasons to Buy Daikin


Air-conditioning
specialist

Pioneer in
air-conditioners

The Daikin edge with


in-house manufacturing

High energy
efficiency

Comprehensive range
and quiet operation

Daikin focuses on
air-conditioning solutions
and control systems. As
specialists, its all we
do. No wonder Daikin is
recognised as an expert in
air-conditioning.

Daikin has been providing


air-conditioning solutions for over
15 years in India. As one of the
industrys more trusted names,
Daikin air-conditioning equipment
can be found in homes, offices,
hotels and shops. Daikin is
committed to the air-conditioning
market and has a manufacturing
facility located in Rajasthan.

Daikin is the only company in the


world dedicated to manufacturing
both air-conditioning systems and
refrigerants. Each element has
been designed to work flawlessly
with the next - delivering optimal
performance - from the time a
project begins till the moment of
absolute comfort.

Daikins continuous drive for


improved efficiency has seen its
advanced inverter technology
being applied to split, ducted
and other systems. These systems
provide a more comfortable
environment and are more energy
efficient when compared to noninverter systems.

Daikin has a comprehensive


range of products in both
domestic and commercial
segments. Designed to
provide effective and quiet
air-conditioning, Daikin can
customise a solution to meet
every requirement.

Unmatched
after-sales support

Five-year warranty
on compressors

Wise investment
Low running cost

Experienced
dealers

Environment
friendly

Daikin takes pride in


providing its customers with
efficient after sales support,
including readily available
spare parts warehoused
in India.

Reliability. Thats probably top of


your list when buying an airconditioning system for your home
or business. Daikin gives you
peace of mind and reassurance
with their five-year warranty
on compressors of split airconditioners. Thats how confident
Daikin is about the quality and
reliability of its product.

When you buy a Daikin airconditioning system you need to


look beyond the initial purchase
price. It pays to consider ongoing
running costs in conjunction
with the potential life of the
product. Daikin systems offer
superior build quality and energy
efficiency.

Daikin distributes its products


through experienced dealers.
This ensures that you receive a
top quality product with expert
support. Together this means the
best air-conditioning solution for
your individual needs.

Daikin continues to work


towards a sustainable future,
and has received Environmental
Management System certification
to ISO14001. Daikin
Airconditioning India Pvt. Ltd.
is dedicated to preserving and
protecting the environment
through the production of energy
efficient products.

Terms & Conditions Apply

Contact Address
DAIKIN AIRCONDITIONING INDIA PVT. LTD.
12th Floor, Building No 9
Tower A, DLF Cyber City
DLF Phase III, Gurgaon 122002
Haryana, India
Tel: 0124-4555444, Fax: 0124-4555333
Email ID: communications@daikinindia.com
Sales & Service Offices

Tel: 080-25590452-54
Chandigarh
Tel: 0172-5089862-64
Chennai
Tel: 044-24314210-15

Hyderabad
Tel: 040-39134289

Mumbai
Tel: 022-30926666

Jaipur
Tel: 0141-2223215

Pune
Tel: 020-25560300

Kolkata
Tel: 033-22894259/60

(info@aicl.in)

Bengaluru

Lucknow
Tel: 0522-2787307/340

Service toll free


1800-102-9300, 1800-22-9300
cs@daikinindia.com
Visit us at www.daikinindia.com
/daikinindia

/daikinindia

daikinindiablog.com

/company/daikin-airconditioning-india-pvt.-ltd.

Disclaimer
As a continuing policy of product innovation of Daikin, the design and specifications are subject to change without prior notice. The visuals of the products in the brochure are representative
only, actual products might differ from the ones shown. Sales revenue includes revenue through sales of all Daikin Airconditioning Systems. Worlds no. 1 position based on internal assessment
of total sales revenue for 2012-13.
Products mentioned in this brochure comply with RoHS regulations as per E-waste (Management & Handling) Rules, 2011and should not be mixed with general household waste at the end of
their useful life. For more details kindly visit our website www.daikinindia.com or contact our customer care centre at 1800 102 9300 / 1800 22 9300

concept and design at

Tel: 079-26583013-14

Delhi NCR
Tel: 0124-4555444

DAIPL-2014/14-RA20-1A

Ahmedabad

S-ar putea să vă placă și