LOAD CONTROLS INDIA PRIVATE LIMITED

Mfg: Modular type Power switchboards, control panels & Bus Ducts
No.1,2&3, Survey No.105, Uttari Road, K.Ashwath Industrial Layout, Off Kanakapura Road,
Kagglipura, Bengaluru - 580 082. INDIA. Tele: (080) 30033800.
modular@loadcontrols.net

www.loadcontrols.net

LCIPL/CONT/15-16/ Q-947/ADS

March 1, 2016

To,

R0
M/s. PAVAN ELECTRICALS.,
Bangalore
Kind Attention: Mr. Ravindra Reddy.H.A.

Dear Sir,
Sub
PROJECT

: Quotation for supply of DG SYNC PANEL


: M/s. krishvi dhawala project

ave pleasure in submitting our offer as below


[I]

Scope
Design, Fabrication, Painting, Powder Coating, Assembly, Wiring, Testing and Supply of Modular
Panel Boards, Sheet Steel enclosed, dust and vermin proof, fabricated out of 14 /16SWG
CRCA sheet steel to house the following components :

[II]

Commercial and Technical Offer


1)
2)
3)

Our offer is based on the SLD submitted by yourself for DB mentioned below in commercial offer.
We have considered powder coating using seven tank process and our shade considered is RAL 7032
Our Scope of work involves only Supply of LT panels. Installation and commissioning of
Panels is not in our scope.

[III] Priced Offer-LT PANELS


Sl.
No.
1

Description

SYNCRONISING PANEL (2*250KVA) (IN DOORtype)

Total
[V]

QTY
Nos.

Price per
Panel (Rs)

Total
(Rs)

1076000

1076000

1076000

TERMS & CONDITIONS:


* We have quoted as per your SLD Mail dated on 29 Feb 2016
1) We have not considered PLC in our offer as it is not included in SLD.kindly confirm

[V]

TERMS & CONDITIONS:

rice basis
Payment
Freight
Packing
Loading &
Unloading
s and Duties:

ivery
missioning :

:
:
:
:
:
:

Above prices are exclusive of all taxes & duties.


50% advance and balance against inspection of panels & before despatch.
Extra at actuals.
Polythene packing is cosidered
Loading by LCIPL at LCIPL
Unloading by yourself at destination

The statutory levies rates given under are as applicable at present, however, the rate
applicable at the time of dispatch shall be applicable
a) Excise Duty : extra @ 12.5%
b) VAT : extra @ 14.5%
:3-4 Weeks from the date of approval of drawings.
Is not in our scope. Any assistance if sought in writing by customer, may be
extended to the extent of one visit by our engineer.
Any more visit than one visit shall be charged at Rs. 6000/- per man day, Boarding, lodging
transportation your scope.

r delayed payment :
To be levied @ 24% per annum calculated on simple interest basis for the number of
days the payment is delayed from the due date.

Load Controls India Pvt. Ltd

1 Of 4

LC/MKT/F/2 Rev: 00

Validity
tion of Panels :

: 15 days from today and thereafter subject to our confirmation.


Expenses associated with inspection of panels shall be borne by you.

ated Damages :
No LD shall be applicable unless the same is specifically agreed upon in writing

nd we look forward to the pleasure of receiving your


will receive our best and prompt attention.
anking you,
cerely yours
ROLS INDIA PVT LTD.

AKSHATHA DS
Estimation Engineer

Pramod HS
Sales Engineer.
Ph: 9663396485
e-mail:- pramod@loadcontrols.net

QTY

SET/NO
1

DESCRIPTION
SYNCRONISING PANEL (2*250KVA) (IN DOOR-IP42 )
DG INCOMER - 1 & 2 (250KVA)

Nos

400A TP+NL 36KA MP based Mot.MCCB with O/L,S/C,E/F,S/T releases with RHOM & Spreaders with Aux
& trip contacts
ELR with CBCT

12

Nos

Resin cast CT's 400/5A, Cl-1 15VA

Nos

Resin cast CT's 400/5A, Cl-PS 15VA - REFR

Nos

125A TP AC-3 Duty Power Contctor

Nos

Digital multifunction meter Cl-1,96Sqmm With RS 485 Port

Nos

Digital VAF Meter Cl-1,96Sqmm

Nos

Digital Ammeter Cl-1,96Sqmm

Nos

Counter type KWH meter Cl-1,96Sqmm

Nos

Reverse power relay

Restricted earth fault relay

Nos
Nos

Nos

Push Button Breaker ON /Breaker OFF / ACCEPT / RESET

Set
Nos

Indicating lamps for R-Phase, Y-Phase, B-Phase

4
4

Nos

ON/OFF Illuminated Push Button

Nos

Nos

Indicating lamps for Neutral contactor ON/OFF


Emergency push button

Nos

6A TP MCB 10kA 'C' Curve

Nos

16A FP MCB 10kA 'C' Curve

Nos

6A FP MCB 10kA 'C' Curve

Nos

Hour meter

Nos

LVM

2
2

Nos
Nos

On Delay Timer

Nos

Speed Rise Low Selector Switch

22

Nos

PLA Relay,3 C/O,24V DC

12

Nos

Aux Contacts 2NO+2NC,230V,AC

16
2

Nos
Nos

Aux Contacts 2NO+2NC,24V,DC


8 Window announciator

Nos

Hooter

100

Nos

Terminal blocks

Nos

Load Controls India Pvt. Ltd

Local / Remote selector switch

Indicating lamps for Breaker TRIP

Voltage Rise Low Selector Switch

2 Of 4

LC/MKT/F/2 Rev: 00

Nos

Disconnecting terminal blocks


BUS COUPLER

No

No

400A 4P 36KA MP based MCCB with O/L,S/C,S/T releases with RHOM & Spreaders with Aux & trip
contacts
Local / Remote selector switch

Nos

ON/OFF Illuminated Push Button

Nos
No

Aux Contacts 2NO+2NC,230V,AC


6A SP MCB 10kA 'C' Curve

BATTERY CHARGER CIRCUIT


2

Nos

20A Battery charger (SMPS)

Nos

DC Ammeter-96 sqmm

Nos

DC Voltmeter-96 sqmm

Nos

Indicating Lamps 240V AC RED

Nos

6A SP MCB 10kA 'C' Curve

Nos

25A DP MCB 10kA 'C' Curve

Nos

16A DP MCB 10kA 'C' Curve


SYNCHRONISING SECTION

Nos

No

Generator Control Package - EASYGEN 2500


Double Voltmeter (0-500V)-144 Sqmm

No

DoubleFrequency Meter-Reed type-(45-50-55Hz)-144 Sqmm

No

Synchroscope

Nos

Synchronising lamps 110v Ac

No

Check synch relay

Set

Auxiliary contactors, Relays, Selector switches for control logic

Nos

2 pole 2 way selector switch

Nos

Manual potentiometer
OUTGOINGS

Nos

Nos

063A TP 16KA TM based MCCB with O/L,S/C,S/T releases with RHOM & Spreaders with Aux & trip
contacts
Resin cast CT's 63/5A, Cl-1 10VA

Nos

Digital KWH Meter Cl-1,96Sqmm

Nos

Indicating lamps for ON/OFF/TRIP

6A TP MCB 10kA 'C' Curve

20

Nos
Nos

Nos

Disconnecting terminal blocks

Nos

Nos

100A TP 16KA TM based MCCB with O/L,S/C,S/T releases with RHOM & Spreaders with Aux & trip
contacts
Resin cast CT's 100/5A, Cl-1 10VA

Nos

Digital KWH Meter Cl-1,96Sqmm

Nos

Indicating lamps for ON/OFF/TRIP

6A TP MCB 10kA 'C' Curve

20

Nos
Nos

Nos

Disconnecting terminal blocks

Nos

Nos

125A TP 16KA TM based MCCB with O/L,S/C,S/T releases with RHOM & Spreaders with Aux & trip
contacts
Resin cast CT's 125/5A, Cl-1 10VA

Nos

Digital KWH Meter Cl-1,96Sqmm

Nos

Indicating lamps for ON/OFF/TRIP

Nos

6A TP MCB 10kA 'C' Curve

Load Controls India Pvt. Ltd

Terminal blocks

Terminal blocks

3 Of 4

LC/MKT/F/2 Rev: 00

20

Nos

Terminal blocks

Nos

Disconnecting terminal blocks

No

Nos

250A TP 25KA TM based MCCB with O/L,S/C,S/T releases with RHOM & Spreaders with Aux & trip
contacts
Resin cast CT's 250/5A, Cl-1 10VA

No

Digital KWH Meter Cl-1,96Sqmm

Nos

Indicating lamps for ON/OFF/TRIP

6A TP MCB 10kA 'C' Curve

10

No
Nos

No

Disconnecting terminal blocks

No

Nos

400A TP 36KA MP based MCCB with O/L,S/C,S/T releases with RHOM & Spreaders with Aux & trip
contacts
Resin cast CT's 400/5A, Cl-1 10VA

No

Digital KWH Meter Cl-1,96Sqmm

Nos

Indicating lamps for ON/OFF/TRIP

6A TP MCB 10kA 'C' Curve

10

No
Nos

No

Disconnecting terminal blocks

Set

800A AL. BUSBAR for Phase & 50% For Neutral @ 0.8A/Sqmm

Terminal blocks

Terminal blocks

END OF BOM

Load Controls India Pvt. Ltd

4 Of 4

LC/MKT/F/2 Rev: 00