Sunteți pe pagina 1din 13

UPGRADING

OUR TR
SERIES
FIRMWARE
QUICK SYTART
GUIDE
TR-6000
IMPORTANT: PLEASE READ THESE INSTRUCTIONS COMPLETELY
BEFORE PROCEEDING WITH THIS BETA UPGRADE
Your radio must be running Build 4.0.3 or higher before applying Build 6.1.8. The latest
version of TRUMP Version 109-fw-6.1.0 (Tranzeos Upgrade Program) will update your
radios automatically up to the previous build of 6.1.0. For radios with firmware older than
4.0.3, we now recommend using TRUMP to upgrade to build 6.1.0 and then manually
upgrading to 6.18. TRUMP can be used in Routed or Bridged networks.

Warning: Before applying any versions of firmware please read and understand this entire
document. If you encounter problems with the new firmware you can seek help from the
Support Team. You should only perform a firmware upgrade during support hours (8 am to 5
pm PST, Monday to Friday) in case you need emergency assistance. If you have any
questions, please call or email us before starting the upgrade process. It is advised that
network administrators document their configuration before proceeding with the update, and
manually re-enter the information after the upgrade, if required.
Important: Firmware may become unusable if inappropriately applied or the connection is broken during the
upgrade. Ensure no interruptions during the upgrade. If the connection is broken or the power goes off during an
upgrade, the unit may become inoperative!
Tranzeo, Tranzeo Wireless, Aperto, Aperto Networks, WaveCenter, PacketMax, PacketWave are the trademarks of
Tranzeo Wireless Technologies and all rights reserved.
AirSync, AirConsole, Proximetry trademark of Proximetry, Inc., in the USA and other countries.
Microsoft and Windows are registered trademarks of Microsoft Corporation. MySQL is a registered trademark of
MySQL AB. JBoss is a trademark of Mark Fleury. Java is a trademark of Sun Microsystems, Inc. Intel and Pentium
are registered trademarks of Intel Corporation. AMD is a trademark of Advanced Micro Devices, Inc.

REVISION HISTORY
Rev 0
Rev 1

Initial Document Release


Firmware 6.1.8 release

Page 1 of 13

19473 Fraser Way


Pitt Meadows, B.C. Canada, V3Y 2V4
Phone (604) 460-6002 Fax (604) 460-6005
www.tranzeo.com
01/08/2014
TR2015-618

UPGRADING
OUR TR
SERIES
FIRMWARE
QUICK SYTART
GUIDE
TR-6000
Firmware Table
Product Series
TR-CPQ
TR-CPQ-HWr3
TR-SL2
TR-SL2-HWr3
TR-SL5
TR-SL5-HWr3
TR-SL9
TR-SL9-HWr3
TR-6X00
TR-6X00-HWr3
TR-5A
TR-5A-HWr3
TR-FDD
TR-FDD-HWr3
TR-4.9
TR-4.9-HWr3
TR-Multi
TR-90X
TR-90X-HWr3

Bin File
TR6-6.1.8CPQ.bin
TR6-6.1.8CPQ-HWr3.bin
TR6-6.1.8CPQ.bin
TR6-6.1.8CPQ-HWr3.bin
TR6-6.1.8SL5.bin
TR6-6.1.8SL5-HWr3.bin
TR6-6.1.8CPQ.bin
TR6-6.1.8CPQ-HWr3.bin
TR6-6.1.8Rt.bin
TR6-6.1.8Rt-HWr3.bin
TR6-6.1.8Rt.bin
TR6-6.1.8Rt-HWr3.bin
TR-6.1.8FDD.bin
TR-6.1.8FDD-HWr3.bin
TR49-6.1.8Rt.bin
TR49-6.1.8Rt-HWr3.bin
TR-6.1.8Multi.bin
TR6-6.1.8Rt.bin
TR6-6.1.8Rt-HWr3.bin

Page 2 of 13

19473 Fraser Way


Pitt Meadows, B.C. Canada, V3Y 2V4
Phone (604) 460-6002 Fax (604) 460-6005
www.tranzeo.com
01/08/2014
TR2015-618

UPGRADING
OUR TR
SERIES
FIRMWARE
QUICK SYTART
GUIDE
TR-6000
RELEASE HIGHLIGHTS FOR 6.1.8.
Radio and Wireless

Allow SSID to be blank for client (AP scan mode)


Fixed a memory leak in mpi
Enable 5.1GHz band for Jordan
Change antenna mode for Brazil 900MHz domain to not reduce output power
Various Station power saving improvements for AP and reduce sleep retry overhead
Do not send retries for null frames

UI

Fixed cosmetic bug on QoS webpage, change range setting for ip filter page
Fixed a bug on station list page where page scroll failed when turning off refresh
Added Ethernet link status to System Information page
Fixed distance setting from an imported config file. The unit in the config file is always in meters. It should not
change the user's unit on GUI
Updated webGUI copyright to 2014

Operational Features

Added ping and reboot watchdog functionality


Added SNMP command to drop wireless link and rescan for AP's
Added SNMP read oid for Slots Used from Information Page
Set 5GHz max distance to 61km instead of 110km and set valid range to 0-61km
Updated 900MHz with max range of 55km as per highest it can set in webGUI
Set all default distances to 30km, since that works for all models and is more reasonable than max defaults out
of the box

Known Issues

5GHz defaults to channel 56-64 DFS band for USA which means no transmit for first 60 seconds in defaulted
state

Other Changes

Fixed stack low water stat


The AutoConfig and snmp MIB files are updated to reflect the new options. The current autoconfig.txt is
1.0.12.TXT, and the current MIB is V0.7.

NOTE: Changes in previous versions are listed after the upgrade procedure.

Page 3 of 13

19473 Fraser Way


Pitt Meadows, B.C. Canada, V3Y 2V4
Phone (604) 460-6002 Fax (604) 460-6005
www.tranzeo.com
01/08/2014
TR2015-618

UPGRADING
OUR TR
SERIES
FIRMWARE
QUICK SYTART
GUIDE
TR-6000
Upgrading using TRUMP
New version of TRUMP has been released to support Tranzeo WiFi radio product binaries up to and including
version 6.1.0. TRUMP is Tranzeos Remote Upgrade Management Program, which can allow you to locate and
mass upgrade your network from a single tool.

NOTE: It is recommended that you uninstall any previous versions of TRUMP before upgrading to TRUMP
Version 1.0.9-fw-6.1.0.

Special Note for XP users to save a lot of pain


and suffering.
If you are using Microsoft XP, you MUST uninstall before attempting to install the new TRUMP.
You also should delete the C:\Program Files\Tranzeo\Trump folder manually. This is to ensure
that the new settings are correctly applied.
Please consult the Install Guide for TRUMP-1.0.9-fw-6.1.0.pdf file for step-by-step
installation/uninstall instructions, and on how to use it to upgrade your radios.

CHANGES IN TRUMP 1.0.9-FW-6.1.0

Added released version 6.1.0 binaries for TR-CPQ, TR-SL2, TR-SL5, TR-SL9, TR-6, TR-5a, TR-FDD,
TR-4.9, TR-Multi, and TR-90X for Hardware 2, and 3.

KNOWN ISSUES

TR6000/TR5a and TR-49 models running firmware prior to 4.0.3 will need to upgrade to 4.0.3 first, and
then to 6.1.0.
Need to uninstall previously installed versions of Trump prior to installing this release.
Need to manually delete C:\Program Files\Tranzeo\Trump folder after uninstall to ensure new changes are
used.
Installing on a system with ActivePERL can lead to TrLocator /TRUMP scan failures, especially when
using remote desktop to access the machine running TRUMP.
Workaround: Uninstall ActivePERL.

You can download the latest version of TRUMP from the Tranzeo Support Website.

Victor 2.5
The Tranzeo Victor Program is a utility that allows users to locate and quickly change the IP address of Tranzeo
radios. It sends out a broadcast on the network and displays a list of all Tranzeo radios and their corresponding IP
addresses. Victor 2.5 is the latest release.

You can download the latest version of Victor from the Tranzeo Support Website.

Page 4 of 13

19473 Fraser Way


Pitt Meadows, B.C. Canada, V3Y 2V4
Phone (604) 460-6002 Fax (604) 460-6005
www.tranzeo.com
01/08/2014
TR2015-618

UPGRADING
OUR TR
SERIES
FIRMWARE
QUICK SYTART
GUIDE
TR-6000
Manually upgrading the firmware using the HTTP interface
1.

Log into the radio and go to the Administrative Settings page.

2.

Click Browse to browse to the location of the upgrade file, using the .bin firmware listed in the firmware
table. Dont worry, you will get an error if you select the wrong one but you wont kill your radio. Then
click the upgrade software button to apply the firmware. The radio will upgrade the firmware and then
reboot. All the LEDs including the Power LED will go blank during the upgrade for up to 35 seconds.
This is normal.

3.

Your Radio is now upgraded and will continue to pass traffic after it reboots.

Page 5 of 13

19473 Fraser Way


Pitt Meadows, B.C. Canada, V3Y 2V4
Phone (604) 460-6002 Fax (604) 460-6005
www.tranzeo.com
01/08/2014
TR2015-618

UPGRADING
OUR TR
SERIES
FIRMWARE
QUICK SYTART
GUIDE
TR-6000
Previous Firmware Release Notes
CHANGES IN 6.1.7
RF Performance

Changed India 2.4GHz band settings to use updated rules for EIRP limits.
Updated 5 GHz operation in ETSI operation to support EN 302 502 V1.2.1 (2008-07)

UI

Disabled option "Do not jump outside of current band" for DFS in CPE mode as this is an AP only function
Added the ability to see AP statistics on CPEs Web Interface. The AP must be a Tranzeo TR or SL series AP.
The Wireless Performance page will refresh the peer's signal and noise every 10 seconds.
Now allows the SNMP port to be user configurable
Add bridge table for AP mode

Operational Features

Adds a new roaming threshold feature. This feature is primarily intended for units in mobile applicants.
o Allows the user to set roaming threshold via web interface or config file import
o If APs RSSI drops below the threshold for 2 or more cycles, the CPE disassociates the link and
searches an available AP above threshold (NOTE: available AP must match the CPE's primary or
secondary SSID and security info (WPA/WEP))
If during this scan a more powerful AP is found, the CPE will attempt to link to it
If the scan fails to find a more powerful CPE, it will start a scan for all available
channels and if any AP's match the SSID but below the threshold, it will connect for
10 seconds, then repeats the scan.

These are the following VLAN changes:


o Add config file for the non-vlan access feature.
o Enable non-vlan/vlan access for Victor by default.
o Enable a pop-up warning when the non-vlan access feature is enabled and user switches network mode
(bridge<->router).
o Allows setting VLAN on one side and non-VLAN on another side, it works in bridge and router mode.
o Adds an option to allow WEB access via non-VLAN on Ethernet interface in VLAN mode.
o Adds an option to allow Victor access via both non-VLAN and VLAN on Ethernet interface in VLAN
mode.
The last two changes only work in bridge mode.

Allow device accessible in CPE mode with missing or bad radio


Fixed a bug which caused power cap setting failure for 5GHz and CPE mode
Fixed power setting which caused power lower than power cap for 11b mode for 900M. Will result in higher
11b output power from previous firmware.
Fixed bugs of DHCP client and server in VLAN + ROUTER mode
o DHCP client packet was not tagged
o DHCP server packet was not tagged

Known Issues

Can be pinged from either VLAN or non-VLAN in router mode


Noise value not always refreshed and displayed on Wireless Performance page

Page 6 of 13

19473 Fraser Way


Pitt Meadows, B.C. Canada, V3Y 2V4
Phone (604) 460-6002 Fax (604) 460-6005
www.tranzeo.com
01/08/2014
TR2015-618

UPGRADING
OUR TR
SERIES
FIRMWARE
QUICK SYTART
GUIDE
TR-6000
Other Changes

Added Support for TR-6719 model


Add HWr3 support for FDD and TR-49 models
Add Narrow band support for 2C and 2D Radio Type
Add support for 4L cards
ipThroughput ports changed to ports 9222 and 9223 due to conflict with AirSync ports.

Autoconfig.txt template updated to version 1.0.11 to support new roaming parameter:


wireless.roaming_threshold = -100
# [INT.-100 - -50] unit:dBm

No Changes were made to the MIB files. The current autoconfig.txt is 1.0.11.TXT, and the current MIB is V0.6.

CHANGES IN 6.1.0
UI & New Features Added:

Tweak SL2 now defaults to CPE Mode, not AP Mode.


Support for HWr3 motherboards. HWr3 motherboards contain a different flash chip.
Enhancement - Added support for 4J, 4K, 6D, 6E, 6F cards.

Bug Fixes:

Fix Fixed a bug in AP Mode which caused MAC Mini or MacBook Pro to be unable to associate when WPA was
enabled
No Changes were made to the autoconfig or MIB files. The current autoconfig.txt is 1.07, and the current MIB is
V0.2.

CHANGES IN 6.0.1
UI & New Features Added:

Tweak - Changed order of Network Configuration Tab in Router Mode to move Static Routes tab to appear after
Advanced
Fix List 5.8 channels for India in Ascending Numerical order
Workaround - Added an option to not attempt a re-association in response to null timestamps from Third Party AP's
stuck beacons.
New-Added buttons to quickly change NAT timeout parameters to Aggressive or Conservative
Tweak - Added validation on web port to only allow numerical values.
New- Added the ability to ignore Locator Protocol probes, used by Victor and old Locator Program, as GUI option.
New -Added the ability to block Locator Protocol reset as GUI option
New-Allow user to block locator reset in config file
3: deny reset and change IP using locator
2: deny reset only
1: deny reset change IP only
0: allow reset and change IP

Page 7 of 13

19473 Fraser Way


Pitt Meadows, B.C. Canada, V3Y 2V4
Phone (604) 460-6002 Fax (604) 460-6005
www.tranzeo.com
01/08/2014
TR2015-618

UPGRADING
OUR TR
SERIES
FIRMWARE
QUICK SYTART
GUIDE
TR-6000

New- Added these new block options to import/export configuration file system:
o Disable reverse DHCP block option for bridge mode and FDD in the file
Fix - Enable the 5.8GHz LED in AP mode for channels 146, 147, 148
Tweak - Added writing of the card type to exported configuration file for the benefit of the Tranzeo Tech Support
team
Tweak - Speed up 5.8 association time. Previously, when the CPE is initially hunting for an AP, it could in some
circumstance exceed the minimum required time period for Radar scanning on the part of a station when not
associated. As there are a significant number of DFS channels to scan through, this could result in a cumulative delay
in association that in some cases would become noticeable. The CPE will still react to radar after the link is
operational on a DFS enabled channel.
Enhancement Added new packet filter rules. The rules are applied in the following order if enabled.
1. Block DHCP (existing)
1.1 deny incoming UDP/TCP packets which of destination port is 67 on WAN interface
1.2 deny incoming UDP/TCP packets which of destination port is 68 on WAN interface
2. Block IGMP (new)
2.1 deny outgoing IP packets which of protocol is 2 on WAN interface
3. Block Locator Probes (new)
3.1 allow outgoing packets which of source MAC address is itself on WAN interface (allow the device itself
probed)
3.2 deny outgoing UDP/TCP packets which of destination port is 17784 on WAN interface
4. Block multicast (new)
4.1 allow outgoing broadcast packets on WAN interface
4.2 deny outgoing multicast packets on WAN interface
Enhancement - Added Brazil domain to DHS with channel compliant to Ansatel rules.
Enhancement - Added 5500-5700MHz band for Licensed use in Peru
Enhancement - Added AP and PxP functionality for SL2 series with HWr3 only
Enhancement Now, in addition to the Redundant File systems for Device Firmware and Device settings, we have
added Redundant EEPROM backup and recovery to protect against an unlikely but theoretically possible case where
the EEPROM contents could be lost on 2B type cards.
Enhancement - Added 5.8GHz band to Malaysia and increase band to 5925MHz
New Added support for new card types (4J, 4K, 6D, 6E, 6F)
New Added support for H5 (OEM)

Bug Fixes:

Fixed leftover '>' character when a station is dropped from the AP station list
Fixed issue with antenna gain being cleared in rare cases on units with built in antennas, resulting in a cosmetic issue.

CHANGES IN 5.0.7
UI:

Changed Frames over 1518 and less than 2048 bytes to Frames over 1544 and less than 2048 bytes on
Ethernet statistic page

Page 8 of 13

19473 Fraser Way


Pitt Meadows, B.C. Canada, V3Y 2V4
Phone (604) 460-6002 Fax (604) 460-6005
www.tranzeo.com
01/08/2014
TR2015-618

UPGRADING
OUR TR
SERIES
FIRMWARE
QUICK SYTART
GUIDE
TR-6000
Bug Fixes:
[902] Fixed power cap per modulation bug introduced in 5.0.6

CHANGES IN 5.0.6
New Features:

Amended 5.8GHz band for India

CHANGES IN 5.0.5
UI:

[1158] Changed label Enable VLAN to Enable MGMT VLAN on network advanced page

New Features Added:

Amended 900MHz band for Brazil.


Based on customer request, added an option to make the web port changeable in bridge mode.
Added support for 4I Cards.

Bug Fixes:

Optimized code to fix memory leak in TCP module, which caused a hard lock-up when accessing web port with
DDOS type requests (attempting thousands of simultaneous logins). This behavior was triggered by bugs in
some monitoring software. While the issue was extremely rare, it is recommended that all user upgrade to
eliminate any chance of this issue.
Optimized code to fix a small memory leak in Web Server module, which caused system crash and hard lock-up
when accessing web port with DDOS type requests. This issue was found when investigating the above issue.
There were no field reports of this issue.
Fixed WPA group key update issue which caused CPE's decryption failure for broadcast packets.
Removed debug output on dongle console (not visible to customer).
[1424] Power LED does not turn back on until power cycle when re-enabling signal LEDs.

MIBS:
The following private Tranzeo MIBs were added:
.iso.org.dod.internet.private.enterprises.tranzeo.stationStat.stnNumber
(number of associated stations)
.iso.org.dod.internet.private.enterprises.tranzeo.assocStation.stnIpAddr
(associated station IP)
.iso.org.dod.internet.private.enterprises.tranzeo.assocStation.stnMacAddr
(associated station Mac address)

Please refer to the updated MIB V0.6 for more details. You can download the latest MIB
from the Tranzeo Support Website.

Page 9 of 13

19473 Fraser Way


Pitt Meadows, B.C. Canada, V3Y 2V4
Phone (604) 460-6002 Fax (604) 460-6005
www.tranzeo.com
01/08/2014
TR2015-618

UPGRADING
OUR TR
SERIES
FIRMWARE
QUICK SYTART
GUIDE
TR-6000
CHANGES IN 5.0.4
UI:

Fixed menu border color (IE7 does not support 'grey', must be 'gray')
Enable auto scroll for TABs frame so that it can be displayed for small screen (IPOD)

FDD Specific Changes


[1178] Enable VLAN setting on Network Advanced page
NAT MODE CHANGES

[1245] New Feature. NAT Connections Timeouts changed to more aggressive values on the CPQ/SL2
series

Previous
60
300
120
7800
20
240

Type

ICMP
UDP
TCP SHORT
TCP LONG
TCP Reset
others

New
10
10
60
7800
20
10

NAT MODE CHANGES

Added the ability to alter the NAT Connections Timeout values to Network Configuration, Advanced
Tab. Please note that this option only appears if radio is in Router mode.

CHANGES IN 5.0.3
NO USER CHANGES

5.0.3 was created solely to facilitate changes on Tranzeos Production Line. There are no feature
differences between 5.0.2 and 5.0.3.

CHANGES IN 5.0.2
UI CHANGES:

Split configuration into Basic and Advanced tabs on the following pages:
o Wireless Settings
o Administrative Settings
o Encryption
o Statistics
o Network Configuration
Disabled option WPA Update Interval in CPE mode since it is AP controlled option
Interface now removes trailing spaces at the end of SSID automatically; when saving an SSID, and when
clicking on an AP with a trailing SSID on AP List

Page 10 of 13

19473 Fraser Way


Pitt Meadows, B.C. Canada, V3Y 2V4
Phone (604) 460-6002 Fax (604) 460-6005
www.tranzeo.com
01/08/2014
TR2015-618

UPGRADING
OUR TR
SERIES
FIRMWARE
QUICK SYTART
GUIDE
TR-6000
o

Upgrade will not automatically change SSID containing trailing spaces, but any configuration
applied at firmware 5.0+ will remove trailing SSID.
o Removes trailing spaces when importing configuration settings
Added IP address hyperlink on AP's Stations List page to open CPEs HTTP Interface in new tab
Updated System Performance page to prevent memory leak in IE7 and Firefox 3.5 browser. Leak occurred
on client PC, not in radio.
Wireless Performance page now refreshes the RSSI value
Added pop up message box informing user of "Re-associate on new IP" feature may not be compatible with
non-Tranzeo AP's when in DHCP client mode
Added Numbers to the WEP Key boxes
Now display system uptime on Information page.
o PxP mode has additional link uptime.
Note: FDD may be off up to 6 seconds due to polling
HTTP Interface now prevents 0.0.0.0 from being set as the default route. This prevented the DHCP
gateway option from being set in DHCP client mode in firmware 4.0.3
Changed Network mode drop down box to be compatible with Chrome browser
Fixed ARP Table page to clear IP address column when last page isn't completely filled
Combined Configuration page for bridge/router mode

NEW FUNCTIONS ADDED:

Added feature to block DHCP servers behind bridged CPEs from serving other clients on the AP
Added configuration settings to autoconfig function:
o net.reverse_dhcp_block (new)
o net.shaping_rate (new)
o net.shaping_policy (new)
o net.router.qos.uplink_speed (value range changed)
o net.shaping_policy (new)
Implemented a TCP throughput test, requires throughput.exe, a Windows Command line tool.
o TCP server mode enabled all the time and supports wireless or wired upstream and downstream.
Usage:
TCP input test (sending data IN to device)
throughput.exe -i -r [seconds] [ip_of_radio]
TCP output test {receiving data OUT of device)
throughput.exe -o -r [seconds] [ip_of_radio]
Added a basic traffic shaping feature to shape traffic transmitted from the device:
o Enabled by default with unlimited default value
Works in Bridge mode, but doesn't have the QoS classification feature
o Router mode still has the QoS classification feature
o Shaping applies to aggregate throughput, so for an AP, a setting of 10000 kbps would be shared
amongst all CPEs, not per CPE
o Added ability to set numerical traffic limit instead of fixed rates
o QoS enabled AP will not have Shaping enabled on upgrade, but QoS enabled CPE in router mode
will be converted to numerical traffic limit and remain enabled
Firmware now returns the firmware version in Victor response
Added IP address hyperlink on AP's Stations List page to open CPE in new tab
Enabled 1/4 and 1/2 channel support for card type 6C
Radio now checks before process files in case users accidently tries to import a firmware image instead of
settings file
Display system uptime on Information page.
o PxP mode displays additional value of Link Uptime.
Note: FDD may be off up to 6 seconds due to polling

Page 11 of 13

19473 Fraser Way


Pitt Meadows, B.C. Canada, V3Y 2V4
Phone (604) 460-6002 Fax (604) 460-6005
www.tranzeo.com
01/08/2014
TR2015-618

UPGRADING
OUR TR
SERIES
FIRMWARE
QUICK SYTART
GUIDE
TR-6000
MODELS SPECIFIC ENHANCEMENTS:

[FDD] Added slave board status and added client stats

MODELS SPECIFIC BUG FIXES :

[FDD] Fixed MAC address validation in PxP MAC address fields


[900] Fixed stability issue when configuring 1/4 channel in PxP mode

NOTE:

Please refer to the General Firmware Changes document for older


firmware changes.

Page 12 of 13

19473 Fraser Way


Pitt Meadows, B.C. Canada, V3Y 2V4
Phone (604) 460-6002 Fax (604) 460-6005
www.tranzeo.com
01/08/2014
TR2015-618

UPGRADING
OUR TR
SERIES
FIRMWARE
QUICK SYTART
GUIDE
TR-6000
Management Access in Each VLAN Option
VLAN Option = VLAN on Ethernet
In this use case, the Radio will only respond to matching tagged traffic
when accessed via the Ethernet Interface.
When accessed via the Wireless interface, the radio will only respond to
untagged traffic.
Traffic through the radio is unaffected, on traffic sent to the services
(SNMP, TFTP, Victor, HTTP, DHCP, Etc) at the IP of the radio is considered
by this function.

Traffic must be in VLAN 54


To Access Webserver

Untagged

Install Laptop

VLAN Option = VLAN on Wireless


In this use case, the services will only respond to matching tagged traffic
when accessed via the Wireless Interface.
When accessed via the Ethernet interface, the radio will only respond to
untagged traffic.
Traffic through the radio is unaffected, on traffic sent to the services
(SNMP, TFTP, Victor, HTTP, DHCP, Etc) at the IP of the radio is considered
by this function..

Traffic must be in VLAN 54


To Access Webserver

Untagged

Install Laptop

VLAN Option = VLAN on All


In this use case, the services will only respond to matching tagged traffic
when accessed via the either Interface.

VLAN 54
ust be in rver
Traffic m
ss Webse
To Acce

Traffic
must
To Acce be in VLAN 54
ss Web
server

Traffic through the radio is unaffected, on traffic sent to the services


(SNMP, TFTP, Victor, HTTP, DHCP, Etc) at the IP of the radio is considered
by this function..

Install Laptop
Special Options: Allow Web Access on Ethernet without VLAN and Allow Victor to Access Radio on Ethernet Without VLAN.
Some customers may wish to allow access to the Web Server or by Victor regardless of VLAN status. Selecting these options will allow untagged traffic access to those
interfaces regardless of VLAN status.
This feature is used most often to allow installers to access the radio without needing to set a VLAN in their laptop.

Page 13 of 13

19473 Fraser Way


Pitt Meadows, B.C. Canada, V3Y 2V4
Phone (604) 460-6002 Fax (604) 460-6005
www.tranzeo.com
01/08/2014
TR2015-618