Bulletin 2574-M1/DE

Installationsanleitung
Serie DFT

ProportionalWegeventil

Parker Hannifin GmbH


Hydraulic Controls Division
Gutenbergstr. 38
41564 Kaarst, Deutschland
Tel.:
02131-513-0
Fax:
02131-513-230
www.parker.com/de
Copyright 2000 by Parker Hannifin GmbH

Inhalt

Proportional DC Valve
Series DFT

Installation Manual

Note
This document and other information from Parker Hannifin GmbH, its subsidiaries,
sales offices and authorized distributors provide product or system options for
further investigation by users having technical expertise. Before you select or use
any product or system it is important that you analyse all aspects of your
application and review the information concerning the product or system in the
current product catalogue. Due to the variety of operating conditions and
applications for these products or systems, the user, through his own analysis and
testing, is solely responsible for making the final selection of the products and
systems and assuring that all performance and safety requirements of the
application are met. The products are subject to change by Parker Hannifin GmbH
at any time without notice.

IA DFT UK.PM6.5 04.04.01

Hydraulics

Home

Parker Hannifin GmbH


Hydraulic Controls Division

Proportional DC Valve
Series DFT

Installation Manual
Function Description
The integrated valve electronics include the following
functions:
Differential command input for voltage or current
signals
Adjustable ramp generator
Flow offset adjustment (MIN) and deadband
compensation
Maximum adjustment (MAX) to maintain full
use of the command signal range over the
actual flow spectrum set with this adjustment
Pulse width modulated current signals for both
valve solenoids
Standard central connection socket
There is a linear relationship between the solenoid
current and the input signal. The solenoid current is
stabilised against voltage fluctuations as well as
temperature dependent resistance variations of the
solenoid coils. Because of the effect of load on the
position of the valve spool, the spool position can
vary and there is a limited relationship between the
input signal and the valve flow.

Type-code Extract

EMC
EN 50081-2
EN 50082-2

EN 55011
ENV 50140
ENV 50204
EN 61000-4-2

EN 61000-4-4
EN 61000-4-5
EN 61000-4-6

Electrical Specification
Supply Voltage

Direct operated D1FT

Range

Pilot operated D*1FT

Supply Voltage Ripple

14.5...30VDC
max. 5%

Current Consumption

max. 2.8A

Input Signal

Voltage Input

0...+/-10V / 100KOhm

Range

Current Input

0...+/-20mA / 500Ohm

Reference Output

10V / 5% max. 10mA

Range of Adjustment for Ramp Time

0...3 seconds

Environmental Temperature Range

-20...+60C

Cabling Cross-section

min. AWG17 shielded

Leads Length

max. 50m

Required Supply Fuse

6.3A medium lag, DIN 41571

Contact Loading (only Code 1)

60V = / 16A

Order No. for Accessories (not included in delivery):


7-pole Plug (Main Connection)

5004072

5-pole Plug (Solenoid switch-off)

5004091
*max. 30VDC against pin G (ground)

IA DFT UK.PM6.5 04.04.01

Hydraulics

Home

Parker Hannifin GmbH


Hydraulic Controls Division

Proportional DC Valve
Series DFT

Installation Manual
Block Diagram of the Electronics

Connection

Electronic option (Code 1) with solenoid disable


For this version the connection from the electronics to the solenoids are made via an additional 5-pole plug
connection, so that a separate disable of the solenoids can be made by external contacts.

* Please see function diagram


IA DFT UK.PM6.5 04.04.01

Hydraulics

Home

Parker Hannifin GmbH


Hydraulic Controls Division

Proportional DC Valve
Series DFT

Installation Manual
Function diagram
Standard configuration
Model

command
signal polarity

Only for electronic option 1


(Solenoid switch-off)

flow
direction

interruption
between
contact pins

effect:
interruption of
the flow
from ... to ...

P-A

B and A

P- A

P-B

B and D

P-B

P-B

B and A

P-A

P-A

B and D

P-B

P-B

B and A

P-A

P-A

B and D

P-B

Potentiometer

Command signal polarity

D1FT

D31FT

D41FT
D81FT
D91FT

Ramp Time and Adjustment Diagram


The valve electronic provides a linear ramp
characteristic in order to maintain a smooth
movement of the solenoid coils. The time can be
adjusted from 0 to 3 sec.

P4 (Ramp B)

+ on

+ off

P1 (Ramp A)

- off

- on

IA DFT UK.PM6.5 04.04.01

Hydraulics

Home

Parker Hannifin GmbH


Hydraulic Controls Division

Proportional DC Valve
Series DFT

Installation Manual
MIN-/MAX Setup

Measurement of the Solenoid Currents

The valve electronic provides a linear ramp


characteristic in order to maintain a smooth
movement of the solenoid coils. The time can be
adjusted from 0 to 3 sec.

The current to the solenoids can be measured in so


far as a current measuring instrument is connected
in series between the solenoid supply lead and the
appropriate connectors X1 or X3. The maximum
current at 100% of command is approximately
2.5A.

Set-up procedure:
1) Feed in a command signal of +200mV (resp. +
0.4mA) at the input D.
2) Adjust offset for corresponding valve side by
potentiometer "MIN B".
3) Feed in a command signal + 10V (resp. +
20mA) at the input D.
4) Adjust the required spool stroke (required flow)
for corresponding valve side by potentiometer
"MAX B".
5) Repeat this procedure for opposite valve side.
Feed in negative command signals and adjust
by using potentiometers "MIN A" and "MAX A".
6) Take into account that MIN has to be adjusted
before MAX.
7) See function diagram.
Mechanical Arrangement of the Electronics

IA DFT UK.PM6.5 04.04.01

Hydraulics

Home

Parker Hannifin GmbH


Hydraulic Controls Division

Proportional DC Valve
Series DFT

Installation Manual

INSTALLATION GUIDE TO VALVES WITH ONBOARD ELECTRONICS


TO PROVISION OF ELECTROMAGNETIC COMPATIBILITY
Power Supply
The utilized power supply has to comply with the EMC standards (CE sign, certificate of conformity).
Parker is offering the following power supplies:
EX00-N01
EX00-N04
EX00-N08

( 2.5 Amp.)
( 5.0 Amp.)
(10.0 Amp.)

Relais and solenoids operating from the same supply circuit as the valve electronics has to be fitted by
surge protection elements.

Wiring Cable
The wiring cable between the control cabinet and the valve has to be shielded. The central wiring has to
be installed from a 7 wire cable that utilizes a common shielding and a cross section of min. AWG17. For
the connection of the option "Solenoid disable / Supervisory output" a similar cable has to be used. The
capacity should not exceed a value of approx. 130 pF/m (wire/wire). The maximum cable length is 50 m.
No power current lines may be placed in parallel to the valve's wiring cables. The cable shield has to be
connected to earth ground at both ends (see also chapter "Grounding"). Please be aware of g round loops.

Connectors
The central connection of the valve electronics needs a connector 6pin+E according DIN 43563 featuring
metal case and integrated cable shield coupling. Use a similar connector 5pin for the connection of the
optional "Solenoid disable / Supervisory output" function. Parker can provide suitable connectors:
5004072
5004091

(Connector 6pin+E)
(Connector 5pin)

The connectors has to be installed according the connection diagram, the cable shield has to be tied on
the whole periphery to the provided coupling clamp.

Grounding
The mounting plate of the valve has to be connected to the grounded metal machine frame. The earth wire
to pin G of the central wire cable as well as the cable shields of the valve connection cables should be
tied to earth ground at the control cabinet. A low-ohmic potential compensation wire has to be provided
between the control cabinet and the machine frame (cable wire AWG7 cross section) to prevent ground
loops.

IA DFT UK.PM6.5 04.04.01

Hydraulics

Home

Parker Hannifin GmbH


Hydraulic Controls Division

Proportional DC Valve
Series DFT

Installation Manual

IA DFT UK.PM6.5 04.04.01