Sunteți pe pagina 1din 6

Bulletin 5715-473

Installation Manual
Series EW101

Power Amplifier for


DC Valves

Parker Hannifin GmbH


Hydraulic Controls Division
Gutenbergstr. 38
41564 Kaarst, Germany
Tel.:
(+) 2131-513-0
Fax:
(+) 2131-513-230
www.parker.com
Copyright 2000, Parker Hannifin GmbH

Contents

Power Amplifier for DC Valves


Series EW101

Installation Manual

Note
This document and other information from Parker Hannifin GmbH, its
subsidiaries, sales offices and authorized distributors provide product or
system options for further investigation by users having technical
expertise. Before you select or use any product or system it is important
that you analyse all aspects of your application and review the information
concerning the product or system in the current product catalogue. Due
to the variety of operating conditions and applications for these products
or systems, the user, through his own analysis and testing, is solely
responsible for making the final selection of the products and systems
and assuring that all performance and safety requirements of the
application are met. The products are subject to change by Parker
Hannifin GmbH at any time without notice.

IA EW101 UK A5.PM6.5 RH

Hydraulics

Home

Parker Hannifin GmbH


Hydraulic Controls Division

Power Amplifier for DC Valves


Series EW101

Installation Manual
Electronic module for the control of pilot operated
proportional directional valves with transducer. The
flow direction at the valve spool is set by the sign of
the set-value voltage. The spool stroke and its rate
of change is set by means of potentiometers. The
movement profile of the valve spool is controlled by
a closed loop feedback circuit in the module.
Features
Modulated valve-spool control by 4 selectable
set values, adjustable from 0 to 100% and UP/
DOWN ramp potentiometers.
DIP-switch from internal ramp generation to
external ramp setting.
Pulsed low loss amplifier power stage with
supporting constant current control for consistant temperature-independant solenoid forces.
Dither generator with applied frequency to improve static characteristics.
Diagnosis of spool stroke by means of diagnostic sockets as well as LEDs for indicating working conditions.
Characteristics
Power supply
Power required
Set value voltage
Input select voltage
Reference outputs
Solenoid output current max.
Ramp times
Ambient temperature
Connection
Shielded cable connections
Fuse

Ordering Code

filtered: 22...38V, unfiltered: 18...26V


max. 40VA
0...+10VDC and 0...-10VDC
5...30VDC
+10V / -10V , max. 10mA
1.3A
0...5 sec.
0...+70C
31pole male connector, DIN 41617
Supply connections and valve: AWG16; Commands: AWG20
2A medium lag, DIN 41571

101

EW
Electronic module
DC Valves

Code

Valve
size

10
16
25
26
32

D31FS
D41FS
D81FS
D91FS
D111FS

Mount.
patt.

Valve
size

Module
type

Valve
stroke

NG10 5mm
NG16 6mm
NG25 9.3mm
NG25 6.5mm
NG32 15mm

Design
series
Code

Module type

101

Amplifier, 4 command channels,


Up/Down ramps

IA EW101 UK A5.PM6.5 RH

Hydraulics

Home

Parker Hannifin GmbH


Hydraulic Controls Division

Power Amplifier for DC Valves


Series EW101

Installation Manual
EMC
EN 50081-2
EN 50082-2

EN 55011
ENV 50140

EN 61000-4-4

ENV 50204

EN 61000-4-5

EN 61000-4-2

EN 61000-4-6

Block Diagram

Connector (Elevation B)

2
4
6
8

Input preselect direction, channel 2


Input preselect direction, channel 4
Input set value lock on, channel 2
Input set value lock on, channel 4

1
3
5
7
9
11
13

Input preselect direction, channel 1


Input preselect direction, channel 3
Input set value lock on, channel 1
Input set value lock on, channel 3
Reference potential 0 V transducer
Reference potential 0 V supply
Input ramp disable

16
18

Output +10 V reference


Input 24 VDC supply

17
19

Output -10 V reference


Input transducer signal

22
24
26

Input external ramp option


Output control solenoid B
Output common solenoid A+B with
possibility for external switch connection

23
25
27

Output, transducer supply


Output control solenoid A
Input external ramp option

IA EW101 UK A5.PM6.5 RH

Hydraulics

Home

Parker Hannifin GmbH


Hydraulic Controls Division

Power Amplifier for DC Valves


Series EW101

Installation Manual

Operating and Diagnostic Elements (Elevation A)

Notes
14
58

Turn off the electrical power to


this board whenever the hydraulic supply to the valve is
not on.

910
11

Always turn off the power to


this board before removing it
from the card holder.

12
13
14
15
16

Set value potentiometer S1S4


Green LED`s for channel activity of the set
value
Red LED`s for stroke direction indication
Yellow LED for:
correct voltage supply
correct transducer connection
Red socket for spool diagnostic
Black socket for spool diagnostic (0V potential)
Blue grip strip with reference information for
measured values on the measuring sockets
UP ramp potentiometer
DOWN ramp potentiometer

Dimensions

IA EW101 UK A5.PM6.5 RH

Hydraulics

Home

Parker Hannifin GmbH


Hydraulic Controls Division

Power Amplifier for DC Valves


Series EW101

Installation Manual

INSTALLATION GUIDE TO ELECTRONIC MODULES


TO PROVISION OF ELECTROMAGNETIC COMPATIBILITY.
Power Supply
The utilized power supply has to comply with the EMC-standards (CE-sign, certificate of conformity).
Parker is offering the following power supplies:
EX00-N01
EX00-N04
EX00-N08

( 2.5 Amp.)
( 5.0 Amp.)
(10.0 Amp.)

Relais and solenoids operating from the same supply circuit than the valve electronics has to be fitted
by surge protection elements.

Wiring Cable
The wires between the installation site of the module and the peripheral units, as power supply, valve
solenoids, position transducer, command signal source has to be shielded. The following wire sizes
must be reached: power supply AWG 16, other connections AWG 20. The capacity should not exceed
a value of approx. 130 pF/m (wire/wire). The maximum cable length is 50m. No power current lines may
be placed within the wired shielded cables to the electronic module. The cable shield has to be
connected to ground at both ends (see also chapter Grounding). Please be aware of ground loops.

Connectors
The connection of the position transducer needs a sensor connector 4pin+E featuring metal case and
integrated cable shield coupling. Parker can provide suitable connectors:
5004108

(Connector 4pin+E)

The connectors has to be installed according the connection diagram, the cable shield has to be tied
on the whole periphery to the provided coupling clamp.

Installation
The module has to be mounted within a conductive, shielded enclosure. Usable is i.e. an EMC-approved
control cabinet. A perfect grounding of the enclosure is mandatory (see also chapter "Grounding").

Grounding
The mounting plate of the valve has to be connected to the grounded metal machine frame. The cable
shields must be tied to ground at the control cabinet. A low-ohmic potential compensation wire has to
be provided between the control cabinet and the machine frame (cable wire >AWG 7 cross section) to
prevent ground loops.

IA EW101 UK A5.PM6.5 RH

Hydraulics