INSTRUCTION MANUAL

TO: BMM ISPAT LIMITED


VERTICAL SLURRY PUMPS
MODEL: CVP-80-302-50 SA (HC)

CREATIVE ENGINEERS
MANUAL FOR CVP RANGE PUMPS
INSTALLATION
Smaller Sump Pumps are intended to be either suspended by the
accompanying lifting handle or anchored to e.g. steel beams. The larger
units, from the CVP- 150 330-150 and larger, are intended solely for
permanent installation. Enlarged base plate and discharge pipes are available
as extra accessories for all pumps to be used in stationary installations. The
pumps must always be installed in such a manner that the pipelines do not
transmit stresses to the pump, either in the cold or warm state. If the pumps
are suspended freely from the lifting handle, the discharge line must consist
of a flexible hose. The pumps are not self-priming, which means that the
pump casing must be filled when the pump is started. Once the pump is
pumping, it has good suction capacity up to 2-3m. Pumps with semi-open
impellers should not be used with suction pipes.
When pumping slurries with a strong tendency to settle, the pump casing
with spray holes is recommended. Pumps CVP-213-80 and larger can also
be equipped with a special cutter for maximum agitation. The pump casing
should be located max. 300mm from the bottom of the sump, which should
be designed to avoid dead spots. Contact Creative engineers for more
detailed recommendations. Note that the pumps bearing cylinder may not
be submerged.

DRIVE EQUIPMENT
The CVP Pumps are normally V-Belt driven in order to prevent adjustment
of shaft speed to existing data. General instructions for V-Belt drive are
provided separately
Standard base-mounted electric motors are placed on the adjustable motors
shelf. The table gives the largest motors size (4 pole motors in accordance
with IEC dimension) that will fit on the shelf.

Page 2 of 11

CREATIVE ENGINEERS
MANUAL FOR CVP RANGE PUMPS
PUMP TYPE
CVP 60-160-25
CVP 120 180 160-25
CVP 80 230-50 301-50, 300-50
CVP 80 230-50, 301-50, 300-50
CVP 120-180, 230-50, 301-50, 300-50
CVP 80 214-80/280-100/334-100/330-100
CVP 120-180 213-80/280100/330-150/330-100
CVP 100 330-150
CVP 180 330-150
CVP 150 450-200 500-200 , 180-509-200
CVP 150 5300-250

Motor
Type

Rating
(4Pole)

IEC
132 M
200 L
132 L
132 M
200 L
200 L
225 M
225 M
315 S
315 S
315 MA

KW
7.5
30
30
7.5
30
30
45
45
110
110
132

Pumps with direct coupled motors: see separate instruction.

START
1. Check all screws, nuts and bolts holding the pump and tighten if
necessary. They may have come loose during transport.
2. Remove all foreign objects form the sump. This is particularly important
if the pump has rubber-lined wear parts.
3. Check that the pump shaft rotates in right direction. It should rotate anticlockwise as viewed from the drive end. Direction of rotation is also
indicated by an arrow on the bearing cylinder.
NOTE: The CVP-230-50, 301-50 and300-50 has been threaded on
impellers. If the pump is started in the wrong direction, the pump parts
may be damaged. Before checking the direction of rotation, always
disconnect the drive. Other pumps can be started in the wrong direction
without being damaged.
4. Pumps equipped with cutter have a screwed shaft end (left hand). Before
checking the direction of rotation the drive must be dismantled.
5. If the pump has been idle for a long period of time prior to starting up,
the bearing must be lubricated. See under Lubrication instruction.

Page 3 of 11

CREATIVE ENGINEERS
MANUAL FOR CVP RANGE PUMPS
6. Check the coupling if direct drive is fitted refer to separate instruction.
7. Start the pump.

OPERATION
1. Check that the pump runs smoothly and without vibration.
2. Check the capacity or the pump conforms to the performance
requirement and adjust the speed if necessary.
3. Follow the lubrication instructions and instruction for V-belt drive,
including checking V-belt tension after a certain period of operation.
4. If the pump suddenly begins to vibrate violently, the most common
reason is that a large object has become jammed in the impeller and is
causing imbalance. If this happens, the pump should be stopped
immediately and the pump parts checked.
5. If the shaft is more than 3/100 mm out of the line at the impeller
fastening it must be corrected. Contact Creative Engineers for
instructions.

REPLACING WEAR PARTS


The pumps are made in two variants. Namely:
Pump casing with spray holes and semi-open impeller. This is designated
S and is available in sizes 214-80S, 280-100S, 330-150S, and 450200S.
The other variant has the same wear parts as the corresponding horizontal
pump.i.e.sizes
160-25,230/301/50,300-50,213-80,280-100,330150,450/500-200,and 5300-250.sizes 160-25 and 230/301-50/300-50
have semi-open impeller, other closed.

Page 4 of 11

CREATIVE ENGINEERS
MANUAL FOR CVP RANGE PUMPS
IMPELLER ATTACHMENT
The Impeller for the CVP-230-50, 302-50 and 300-50 is threaded directly
onto the shaft with a left-hand thread.
The CHP-450-200-500-200, 500-200and 5300-250 have taper and key. For
dismantling these impellers a puller is included in the delivery.
The fastening components used to secure the impeller must be checked prior
to the impeller. The washer shall be flat and any pieces of rubber underneath
the screw head must be removed. On impellers with tapered hubs, it is
important that the tapers on both the shaft and the impeller are clean and
have the correct shape.
On occasions when the impeller has come loose during operation, it is an
absolute requirement that the taper has to be checked with a taper gauge
before a new impeller is mounted. Both impeller and shaft tapers must be
checked.
Other CVP pumps have a cylindrical guide and the torque is transmitted by
the square shaft end, which fits into the matching impeller bore. The bore is
locked to the shaft by means of a socket hex screw. The screw is locked into
the shaft by a Heli-Coil mid-Grip threaded insert with a lock turn. The screw
must always be greased before tightening with molybdenum (MoS2).
After removing the old impeller, clean the shaft end and the new impeller
before mounting. IMPORTANT! Never grind the bore! This ruins the fit and
can ruin the impeller attachment.
If the pump has to stand idle for a long period of time without the impeller
mounted, the end of the shaft should be treated against corrosion. If the
impeller is stuck on the shaft, the bearing cylinder with shaft can be pulled
upwards by means of the adjusting screws in the bearing cylinders upper
flange until the impeller comes loose from the shaft (not CVP-230-50, 30150 and300-50). Note that the shaft has to be lowered before the new impeller
is mounted.

Page 5 of 11

CREATIVE ENGINEERS
MANUAL FOR CVP RANGE PUMPS
The strength class for black and acid proof screws shall be 8.8 ONLY
QUALITY-MARKED SCREWS MAY BE USED. Black screws marked
with 8.8. Acid proof screw marked with A4-80. The screw shall be
lubricated on its thread and underneath the head. Recommended lubricant:
Molykote 1000 or molykote 3212.
The tightening torque for the impeller screw is as follows:
Pump type
CVP-160-25
CVP-230-50, 302-50,300-50
CVP-213-80/214-80S
CVP-280-100/285-100S/330-100S/334-100
CVP-330-150/330-150S
CVP-450-200/450-200 S 500-200
CVP-5300-250

Tightening torque
KPm
Nm
5.3
1)
43
43
43
43
75

33
1)
430
430
430
430
750

1. The impeller is threaded directly onto the shaft with a left hand thread.
In order to be sure the impeller does not rub against the pump casing when it
is tightened, check that the shaft rotates freely after tightening. The impeller
screw is protected by a rubber-clad cap with plug. The plug must be glued
on.

PUMP CASINGG AND INLET SECTION


Rubber-lined version:
The CVP-160-25, 230-50,301-50.300-50 and all sizes with spray holes in the
pump casing have rubber-lined pump casing and inlet sections. When
necessary, the entire component must be replaced.
The CVP-213-80 and larger pumps i.e. versions with closed impeller and
casing without spray holes, have replaceable liners for the pump casing and

Page 6 of 11

CREATIVE ENGINEERS
MANUAL FOR CVP RANGE PUMPS
inlet section. Before fitting the new liner for then pump casing, pull the
outlet neck into the volute. See the illustrations below:
- Pull the liners outlet neck into the volute.
- Lubricate the liner with e.g. Water + soap and press it into the casing.
- Fix the liner in place with nuts on the four screws.
- Dont forget the metal washer before tightening the nuts.
Adjust the position of the liner in the pump casing.
If there is a risk that pumps with replaceable liners may suck air, the liner
should be glued with e.g. Tip-Top 2000.
Following normal installation, simply tuck the liner down into the casing,
wipe and wash away any lubricant and apply glue around the periphery and
upper part of the liner (towards the inlet section).
Replace the inlet liner and tighten it in the inlet section. In addition, a metal
washer and must be used at the suction flange in order to prevent the liner
from being pulled in during operation.
The CVP-5300-250 has a 2-part pump casing and lining. Fit the liner halves
in the casing. Assemble the casing halves. Dont forget the shims between
the casing halves. Before finally tightening the nuts, check that the liner
halves fit snugly together at the joint. Adjust with a plastic mallet if
necessary. The pump casing also has a wear washer, which is attached to the
lower flange of the stand pipe with four screws. Replace the entire wear
washer if necessary.

NI-HARD VERSION
Pumps equipped with ni-hard parts do not have replaceable casing liner
(except for the CVP-5300-250). The casing is replaced as a whole when
necessary. The same applies to the inlet section on pumps with spray holes
and semi-open impellers.

Page 7 of 11

CREATIVE ENGINEERS
MANUAL FOR CVP RANGE PUMPS
Pumps with closed impellers (CVP-213-80 and larger) have replaceable inlet
liners.
The CVP-150, 5300-250 has a Ni-hard liner that fits into the two-part
casing. Be careful when fitting. To help guarantee a good fit, rubber packing
are used between the casing halves and the liner. When the casing halves
been tightened together, the machined sealing surface in the liner must be
even with or slightly higher than the matching surface around the rear
opening of the pump casing (towards the stand) to ensure a good seal
between the stand packing and the casing liner.

BEARING REPLACEMENT
The construction of the bearing cylinder is evident from the appropriate
spare parts list. Undo the two covers and the wiper ring. Pull the shaft out in
the direction where the spherical roller bearing is mounted. Before fitting
new bearing, heat them to 80 C. In case of the CVP150/180,360-150 and
450/500-200, the spherical roller bearing is fitted first and then the inner race
of the radial bearing. For other sizes, start with the inner race of the radial
bearing and then the spherical roller bearing. When the bearings have
cooled, insert the shaft into the bearing cylinder. Fit the outer race of the
radial bearing. Pack the bearings with grease (See also Lubrication
Instructions) and the wiper ring.

ADJUSTMENT OF CLEARANCE IN PUMP CASING


It is important for the pump that the clearance between the impellers back
blades and between the impeller and the inlet section is correct. The clearance
is adjusted in two steps: first between the back blades and the casing and then
between the impeller and inlet section. For this purpose, the shaft-bearing
cylinder is adjustable in the axial direction. This is done by means of the
screws in the bearing cylinders upper flange.
The clearance between the back blades and casing shall be:

Page 8 of 11

CREATIVE ENGINEERS
MANUAL FOR CVP RANGE PUMPS
Size
CVP-160-25

Clearance
0.2 - 1.0 mm

CVP-230-50

0.5 - 2.0 mm

CVP-300-50,301-50

0.5 2.0 mm

CVP-213/214-80

0.5 2.0 mm

CVP- 280/285-100/330-100S, 330-100

0.5 2.0 mm

CVP-330-150

0.5 2.0 mm

CVP-450-500-200

1.0 2.0 mm

CVP-5300-250

1.0 2.0 mm

When the clearance has been correctly adjusted, lock the bearing cylinder.
The clearance between the impeller and the inlet table below and shall be
adjusted when necessary by means of space packings.
Clearance
Clearance
Semi-open impeller
closed impeller
Size
CVP-160-25
0.2 1.0 mm
----CVP-230-50

0.5 1.5 mm

CVP-301-50, 300-50

0.5 1.5 mm

1.0 - 2.0 mm

CVP-213/214-80

1.0 2.0 mm

2.0 4.0 mm

CVP-280/285-100

1.0 2.0 mm

2.0 - 4.0 mm

CVP-330-150

1.0 2.0 mm

2.0 4.0 mm

CVP-450/500-200

1.0 2.0 mm

2.0 4.0 mm

CVP-5300-250

mm

-----

2.5 - 4.0 mm

Page 9 of 11

CREATIVE ENGINEERS
MANUAL FOR CVP RANGE PUMPS
LUBRICATION
The bearings are lubrication on delivery with Esso Beacon EP 2, which is a
lithium-based lubricating grease. Equivalent greases of other makers can be
used, but always check first whether they can be mixed with Esso Beacon
EP2.
The pump has only two lube points. These are for the two bearing housing
equipped with lubrication nipples. For pumps will bearing cylinder below the
base plate the nipples are equipped with grease tube and mounted above the
base plate. The pump shall be lubricated first after about 300 operating hours
and then in accordance with the table below, which also indicates the required
quantity of grease.
Greasequantity/
Lube
bearing
Interval
Pump size
CVP-60-160-25
20 g
1500hrs
CVP-120-180 160-25

35 g

,,

CVP-80 230-50 301-50,300-50

20 g

,,

CVP-120-180 230-50 301-50 300-50

35 g

,,

CVP-80 213/214-80

35 g

,,

CVP-120-180 213/214-80

45 g

,,

CVP-80 280/285-100/330-100/334-100

35 g

,,

CVP120-180-220/250-280/285-100/330-100/334-100

45 g

,,

CVP-100-330-150

45 g

,,

CVP-150-180-240 330-150

110 g

,,

CVP-150-240 450-100/500-200

110 g

,,

CVP-150-240 5300-250

130 g

,,

Page 10 of 11

CREATIVE ENGINEERS
MANUAL FOR CVP RANGE PUMPS
The lubrication intervals apply at bearing temperatures of to 70*C. At bearing
temperatures above 70*C, the bearing must be lubricated more frequently as
indicated in the table.
Bearing temperature of 100*C and above are harmful for the bearings and
indicate that a failure is imminent.

STORAGE OF PUMPS
If the pumps have to be stored for a long period of time before use. They
should be stored in dry, clean, well-ventilated areas without large temperature
variations. The pumps should be covered to keep off dust and dirt. If the
pumps are to be stored for longer than six months, remove V-belt drive and
electric motors and treat machined surfaces against rust. Rotate the pump shaft
a few turns at least every 3 months. If conditions are poor, this should be once
a month.

SPARE PARTS
The best way to avoid misunderstandings and prevent incorrect deliveries is to
supply as detailed information as possible. Therefore. State when ordering
spare parts.
Type, designation, and manufacturing number (form the data plate on the
pump).
Name of part, material and part number.
Example:
For CVP-180-509-200
Impeller, rubber-lined, part no: CE-300286.

Page 11 of 11

80

280
140

112
12

680
19(4X)

360

50

430
400

120-138
25

10

550

371

10

125
165

300

35 J6

18

50

38

8
30

500
600

114

M12

23

400

15

430
800
50

846
765

145
295
103

615

900

GA DIMENSIONAL DIAGRAM - PUMP-CVP-80-302-50 SA

CE-80-302-50-001

45

CREATIVE ENGINEERS
CVP TYPE PUMPS
CVP-80-302-50SA
PART LIST
STANDARD

CREATIVE
ENGINEERS

12

Page no:1 of 3

CREATIVE ENGINEERS
CVP TYPE PUMPS
CVP-80-302-50SA
PART LIST
STANDARD

CREATIVE
ENGINEERS

Page no:2 of 3

13

14

4 30

34

3 2

31 33 32 35

CREATIVE ENGINEERS
CVP TYPE PUMPS
CVP-80-302-50SA
PART LIST
STANDARD

CREATIVE
ENGINEERS

Page no:3 of 3

16
26
17
21
18

25
22

20

15

24
23
19

27

36

29

28

CREATIVE ENGINEERS

Manual For CVP Range Pumps


PART LIST FOR CVP-80-302-50SA
ITEM NO

1
2
3
4
5
6
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
61

DESCRIPTION
PUMP COMPLETE
CASING
WEAR PLATE
IMPELLER
INLET
LOWER FRAME
UPPER FRAME
SHAFT WITH BEARING HOUSING
FRAME PLATE
DISTANCE GASKET 5 mm
SHAFT COMPLETE
KEY 10 X 8 X 75
NUT KM 10
LOCK WASHER MB 10
SLINGER
BEARING HOUSING
COVER
SPACER RING
COVER
BEARING NU 310 EC
BEARING 6310 CC
V-RING V-40A
V-RING V-50S
LOCK SCREW M12LH
SHAFT END
DISTANCE SLEEVE
AGITATOR
WASHER
PLUG
GUARD
O-RING 31X3
O-RING 38X3
KEY 11 X 11 X 100

PART LIST
CE-759401-1
CE-256353-1
CE-059507-2
CE-942683-2
CE-257354-1
CE-729258-1
CE-144232-1
CE-241562-M1
CE-003180-4
CE-385285-5
CE-003545-1
CE-P77010-075
CE-P77171
CE-P77122
CE-679110-A
CE-716117-A
CE-762829-A
CE-783131-1
CE-167837-1
CE-P77027
CE-P77027
CE-P77168
CE-P77319
CE-003545-2
CE-302330
CE-302327
CE-302331-1
CE-302332-1
CE-302329
CE-P77302-1
CE-P77302-2
CE-P77018-100

QTY

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Issued No:-01

Issued Date: 19/06/2015

CREATIVE ENGINEERS
PUMP NAME PLATE & COUPLING DETAILS
BMM ISPAT LIMITED
P.O.NO: BMMIL/PROJ/BARM/UTL/PO/15-16/0005
Dt:11/04/2015
S.O.NO: CE/BMM/15-16/04/04
Ref :CE/BMM/14-15/11/417-R2

Parameters

Application-1

Capacity M3/hr
Head M
Specific gravity of slurry
Qty
Pump Model
Pump Speed
Wear parts
Discharge dia in (mm)
Suction Dia (mm)
Max particle size pump can
handle (mm)
Mounting
Drive Arrangement

30 m3/hr
15 mts
1.2
04 Nos
CVP-80-302-50 SA (HC)
1000 rpm
Hi-Chrome
50 mm
65 mm
15 mm
DIRECT COUPLING
DIRECT DRIVE

Motor Recommended
Absorbed power (Kw)
4.2 kW
Motor Rating (Kw)
5.5 kW/ 7.5 HP
Motor Speed RPM
1000 rpm
132 M
Frame Size

COUPLING DETAILS
PUMP COUPLING

: 180 Dia X 35 bore, Key way size 10X8 = 4 Nos

MOTOR COUPLING : 180 Dia X 38 bore, Key way size 10X8 = 4 Nos

Date:- 19/06/2015

WARRANTY CERTIFICATE FOR THE SLURRY PUMPS


To,
M/s,
BMM ISPAT LIMITED
#114, Danapur Village,
Hobli Mariyammanahalli,
Hospet (TQ), Bellery - 583222
Mob No:- 7760970652
Email: rajania@bmm.in

Reference Numbers
Our Offer No
:
Your PO. No.
:
Invoice No
:
Items for warranty :
Qty.
:

CE/BMM/14-15/11/417-R2
Dt.:28/08/2014
BMMIL/PROJ/BARM/UTL/PO/15-16/0005 Dt.:11/04/2015
031,
Dated: 19/06/2015
Creative Make Slurry Pump Model: CVP-80-302-50 SA (HC).
04 Numbers

The Slurry Pump Model: CVP-80-302-50 SA (HC) are warranted for any
manufacturing defects/workmanship for a period of 12 months from the date of commissioning or
18 months from the date of receipt and acceptance. Any defect observed on this account shall be
attended to immediately for any assistance required technically for the supplies made during the
warrantee period.
For Creative Engineers

Authorized Signatory

DATE: 15/06/2015

PERFORMANCE REPORT

1)

Customer

BMM ISPAT LIMITED

2)

P.O. No & Date

3)

S.O. No

4)

Pump Specification

Slurry Pump

5)

Pump Model

CVP-80-302-50 SA (HC)

6)

Wear Parts

Hi-Chrome

7)

Discharge Dia(Mm)

50 mm

8)

Mounting

DIRECT COUPLING

9)

Drive Arrangement

DIRECT DRIVE

10)

Quantity

04 NUMBERS

11)

Capacity

30 m3/Hr

12)

Head

15 m

13)

Motor Rating

5.5 kW/ 7.5 HP

14)

Motor Speed

1000 RPM

: BMMIL/PROJ/BARM/UTL/PO/15-16/0005 Dt:- 11/04/2015


CE/BMM/15-16/04/04

REPORT:
This is to confirm that the pump CVP-80-302-50 SA (HC) has been tested as per the enclosed
curve. This performance of the pump was found to be acceptable and is found to be o.k. for
dispatch.
This pump is cleared for dispatch

Production Manager

Q.C. Manager
Dt : 15/06/2015

RUNNING TEST CERTIFICATE


1) Customer

: BMM ISPAT LIMITED

2) P.O No & Date : BMMIL/PROJ/BARM/UTL/PO/15-16/0005 dt:11/04/2015

3) SL. No

: 2015-16

4) Pump Model

: CVP-80-302-50 SA (HC)

5) Qty

: 04 Nos.

This is to conform that the pump has been under gone running test for 2 hours, the above mentioned
pump is as per manufacturing standard running smoothly as per desired result.

This pump is cleared for dispatch.

Production manager

Q.C. Manager

DATE: 15/06/2015

INSPECTION CLEARANCE REPORT FOR SLURRY PUMPS


NAME OF THE MODEL:

PUMP MODEL : CVP-80-302-50 SA (HC)

PURCHASE ORDER NO. & DT

BMMIL/PROJ/BARM/UTL/PO/15-16/0005
Dt:- 11/04/2015

ITEM DESCRIPTION
CUSTOMER
NAME & ADDRESS OF FIRM

SL.
NO.

SLURRY PUMP
BMM ISPAT LIMITED
CREATIVE ENGINEERS
#1382/204, 1st Main, 15th Cross, Doddanna Indl.
estate, Hegganhalli Sunkadakatte road,
Bangalore-560091

DATE OF INSPECTION CLEARANCE

15/06/2015

Quantity

04 Nos

DESCRIPTION

PUMP SL. NO.

CHECKING
METHOD

DIMENSIONED ANALYSIS

ACCEPT OR
REJECTED

CE/2015-16/

VISUAL

DIMENSION CHECKED WITH


DRAWING AND WAS FOUND OK

ACCEPTED

Slurry Pump Model


1

CVP-80-302-50 SA
(HC)

This is to confirm that, the Creative Make Slurry Pump Model: CVP-80-302-50 SA
(HC) has been tested for dimensional accuracy and desired results are found Ok. It is cleared
for further process.
DT: 15/06/2015
Place: Bangalore

Production Manager

Q.C. Manager

DIMENSIONAL REPORT SHEET


Name Of The Model: PUMP MODEL : CVP-80-302-50 SA (HC)

Part Name/Description
Part/Drawing Number(REV)
CUSTOMER
VENDOR

SL
NO
1
2
3
4
5
6
7
8

CHARACTERISTIC
BEARING HOUSING
IMPELLER
FRAME PLATE
SLINGER
AGITATOR
WASHER
DISTANCE SLEEVE
CASING

Inspected by

: CENTRIFUGAL SLURRY PUMP.


: CE-CVP-80-302-50-C01
: BMM ISPAT LIMITED
: CREATIVE ENGINEERS

SPECIFICATION
AS PER DRAWING NO.
CE-716117-A
CE-942683-2
CE-003180-4
CE-679110-A
CE-302327
CE-302331-1
CE-302330
CE-256353-1

CHECKING
METHOD
VISUAL
VISUAL
VISUAL
VISUAL
VISUAL
VISUAL
VISUAL
VISUAL

P.O. NUMBER:
BMMIL/PROJ/BARM/UTL/PO/1516/0005 DT:11/04/2015
REPORT NO : 01 Dt:15/06/2015

S.O. NUMBER:
CE/BMM/15-16/04/04
DATE: 14/04/2015
NAME OF THE INSPECTOR: Santhosh H.D
NAME OF THE ENGINEER : Prashant

DIMENSION ANALYSIS
DIMENSION CHECKED WITH DRAWING AND WAS FOUND OK
DIMENSION CHECKED WITH DRAWING AND WAS FOUND OK
DIMENSION CHECKED WITH DRAWING AND WAS FOUND OK
DIMENSION CHECKED WITH DRAWING AND WAS FOUND OK
DIMENSION CHECKED WITH DRAWING AND WAS FOUND OK
DIMENSION CHECKED WITH DRAWING AND WAS FOUND OK
DIMENSION CHECKED WITH DRAWING AND WAS FOUND OK
DIMENSION CHECKED WITH DRAWING AND WAS FOUND OK

Checked by

ACCEPT OR
REJECT
ACCEPTED
ACCEPTED
ACCEPTED
ACCEPTED
ACCEPTED
ACCEPTED
ACCEPTED
ACCEPTED

Approved by

REMARKS

INSPECTION CLEARANCE CERTIFICATE


1.

Customer

BMM ISPAT LIMITED

2.

P.O. No. & Date

BMMIL/PROJ/BARM/UTL/PO/15-16/0005

3.

Qty

04 Nos.

DT:11/04/2015

This is to confirm that, the Creative make slurry pump Model: CVP-80-302-50 SA (HC) has been tested for dimensional
accuracy and desired results are found Ok. It is cleared for further process.

This Pump is cleared for dispatch.

Production Manager

Q.C. Manager