1.
504.3
2.
For
(Page 36)
The distance between centres of the main Replace main girders by main outermost
girders shall be sufficient to resist overturning girders
or over stressing due to lateral forces and
loading conditions
504.4(b)
(Page 36)
(Page 37)
Beams and plate girders upto and including Substitute the following for the existing:
35 m span need not be cambered
It is not mandatory to camber beams and plate
girders upto and including 35 m span
507.5.1.2
(Page 63)
The flexural torsional buckling strength of in place of in clause 507.1.2.1 and using
single angle loaded in compression through curve C ( = 0.49) of Fig. 5
one of its legs may be evaluated using the
equivalent slenderness ratio e as given
below:
IR
4.
504.6.2(a)
5.
3.
Read
509.3.1
Table 12
(Page 86)
Second Column
Warping
Restraint Line
1
6.
509.3.1
101
AMENDMENT TO IRC:24-2010
Sl.No.
7.
509.4.2.2(b)
For
tan-1(d/c)
d
-1 c
nearly tan
1.5
(Page 94)
509.5.1
Fig.7 Note 2
(Page 95)
9.
514.4.5
(Page 170)
10.
514.5.9
The method of erection, as also the drawing Substitute the following for the existing:
of the temporary work and the use of erection
The Engineer shall approve the procedure of
equipment, shall be subject to the approval
erection, drawings of temporary works and use
by the Engineer.
of erection equipment, prior to commencement
of erection.
IR
(Page 171)
Panel B is designed without utilizing tension Substitute the following for the existing:
filed action as given in Clause 509.4.2.2(a)
Panel B is designed using simple post-critical
method as given in Clause 509.4.2.2(a)
8.
Read