SECTION 1 : SPECIFICATION
Sensing Input (20, 22, 24)
Voltage
220 520 Vac
1- or 3- phase selectable
180 260 Vac @ 220 Vac
330 520 Vac @ 440 Vac
Frequency
50 / 60 Hz selectable
Voltage Regulation
Less than +/- 0.5% ( with 4% engine governing )
Build Up Voltage
6 Vac 25 Hz residual volts at power input terminal
Soft Start Ramp Time
4 sec. +/- 10%
Environment
Operating Temperature
Storage Temperature
Relative Humidity
Vibration
Response Time
Less than 20 milliseconds
Dimensions
214.0 (L) x 163.0 (W) x 45.7 (H) mm
EMI Suppression
Internal electromagnetic interference filtering
Weight
1130 g +/- 2%
-40 to +70 C
-40 to +85 C
Max. 95%
3.0 Gs @ 100 2K Hz
___________________________________________________________________________________________
2
ADVR-12
45.7
22.0
7.2
214.0
191.0
24.9
Figure 1
Outline Drawing
91.3
ATTENTION
1. AVR can be mounted directly on the engine, genset, switchgear, control panel, or any position that will
not affect operation. For dimension reference please see Figure 1.
2. All voltage readings should be taken with an average-reading voltmeter. Megger or high-potential test
equipment must not be used. Use of such equipment could damage the AVR.
3. Secure all wiring connections. Do not install AVR in a high vibration area to avoid loose connections.
For safety do not touch the heat sink while in operation.
F-
F+
Power
Sensing
Figure 2
___________________________________________________________________________________________
ADVR-12
3.1
CH GND
2
3
5
5a
6
6a
9
20
22
24
TERMINAL
3.5
3.8
3.4
the
generator
is
26
28
30
F1
F2
DESCRIPTION
Ground
Analogue Voltage Input
Connect 4 & 7 for onboard voltage
adjustment.
Connect 10K ohm VR to 6a & 7 for
external voltage adjustment. (keep 4 &
7 Open)
Current Transformer (CT) 1A input
Current Transformer (CT) 5A input
Current Transformer (CT) common
Bridge selection common
Connect 4 & 7 for onboard voltage
adjustment.
Connect 10K ohm VR to 6a & 7 for
external voltage adjustment. (keep 4 &
7 open)
No use (Null)
Connect 9 & 6a for 3 phase sensing
connect.
Keep 9 & 6a open for single phase
sensing.
Single or Three phase sensing input
Single or Three phase sensing input
Three phase sensing input
Connect 22 & 24 for Single phase
sensing input.
Three phase power input
Single or Three phase power input
Single or Three phase power input
Positive excitation output (+)
Negative excitation output (-)
in
___________________________________________________________________________________________
4
ADVR-12
External VR
10K Ohm
5a-6 : 5A CT
6a-9 Close : 3 Phase Sensing
5 5a 6 6a 7
CH
GND
2-3 : +/-5Vdc
Analog Input
5 5a 6 6a 7
ADVR-12
Sensing
20
22
2-3 : +/-5Vdc
Analog Input
ADVR-12
Power
26
24
28
Sensing
30
F1
20
F2
F+
Power
22
26
24
28
30
F1
F2
F+
F-
F-
FIELD
R
CT
CT
GEN
GEN
PMG
FIELD
Figure 3
CH
GND
5 5a 6 6a 7
Figure 4
CH
GND
ADVR-12
Sensing
20
22
26
28
Sensing
30
F1
20
F2
F+
PT1
ADVR-12
Power
24
5 5a 6 6a 7
22
Power
24
26
28
30
F1
F2
F+
F-
PT2
F-
PT1
FIELD
R
CT
CT
GEN
GEN
PMG
FIELD
Figure 6
F+
30
F-
28
26
24
20
22
OUT1
OUT2
S1
S2
Droop
%
ADVR-12
Time
ON
6a
5a
Test
IVT
Fuse
Output
Ready
Test
Batt-Volt
OVLD
B+
Figure 7
___________________________________________________________________________________________
ADVR-12
ATTENTION
1.
2.
3.
4.
5.
6.
___________________________________________________________________________________________
ADVR-12