Site AT after integration - SCFT - BLR04197

Test Case ID

Activity

Handover tests

Remarks
Planned value

Intra-site handover
Site-Eggn04197 Inter-site S1 handover
Inter-site X2 handover

Actual value

Handover delay

19.37

Handover success rate

100

Handover delay

NA

Handover success rate

Performed as a part of cluster optimisation

Handover delay

NA

Handover success rate

Network attach and E-RAB


Site-NE01

Network attach and detach.

Attach success rate


Detach success rate

100
100

Establish success rate

100

Delete success rate

100

Site-NE02

E-RAB establish and delete.

Site-NE03

Subscriber service restoration time after BS reboot

Site-NE04

Paging and TAU update( Y/N)

Attach delay : 307.55ms


Detach delay : 71.88ms

Already Done

Key parameters to be measured are throughput,coverage, latency and jitter at 10 points. The points should be spread in a way covering the entire cell ( center,middle and edges).
Single user outdoor stationary and drive
Throughput and Capacity Test
Planned value

Actual value
Min value

Average
value

Max value

UL Throughput in UDP

0.6

5.3

7.3

UL Throughput in TCP

0.6

5.54

8.87

DL Throughput in UDP

Refer Cluster Optimisation report

DL Throughput in TCP

30.27

Bidirectional throughput in
UDP

Refer Cluster Optimisation report

Bidirectional throughput in
TCP

Refer Cluster Optimisation report

Indoor Coverage

Refer Cluster Optimisation report

Outdoor coverage

Refer Cluster Optimisation report

Min value

Average
value

UDP throughput Performed as a part of cluster optimisation

Site-THR_01

Measurement of UL/DL
Throughput,coverage,latency
and jitter in stationary mode
in TCP/UDP covering all the
way from cell center to cell
edge -- no load on the
neighboring cells

23.21

Jitter

Site-THR_02

Site-THR_04

48.82

Performed as a part of cluster optimisation

Latency

UL/DL
Throughput,coverage,latency
and jitter while driving from
the cell center towards the
cell border with speed
30~50km/hr,50% load in
neighboring cells in TCP/UDP

37.01

1.81

UL Throughput in UDP

Refer Cluster Optimisation report

UL Throughput in TCP

7.92

DL Throughput in UDP

Refer Cluster Optimisation report

DL Throughput in TCP

38.97

Bidirectional throughput in
UDP

Refer Cluster Optimisation report

Bidirectional throughput in
TCP

Refer Cluster Optimisation report

Indoor Coverage

Refer Cluster Optimisation report

Outdoor coverage

Refer Cluster Optimisation report

Latency

Refer Cluster Optimisation report

Jitter

Refer Cluster Optimisation report

Performed as a part of cluster optimisation

Performed as a part of cluster optimisation

DL :69.25
UL : 9.28

Peak throughput achieved by a device in best case possible

Coverage Test
Predicted coverage
plot value
Site-CT01

Outdoor and indoor coverage calculated from above.Plot


values can be compared.

Measured coverage plot value


Refer Cluster Optimisation report

Achieved data rate

Refer Cluster Optimisation report

RSCP Measurement

Refer Cluster Optimisation report

SINR Measurement

Refer Cluster Optimisation report

Performed as a part of cluster optimisation