Documente Academic
Documente Profesional
Documente Cultură
Disclaimer
I have nothing to disclose
Objectives
Describe the process used to determine the new
analyzer selection criteria and outline the steps
that were taken to ensure a smooth
implementation.
Explain the operational and workflow benefits of
the new XN-2000 analyzer.
Discuss the new XN technology and the impact it
has on result reporting and patient care.
Founded in 1903
June 2011 Merged with Sentra Health
System
10 Acute Care Hospitals
August2011New Hospital Opened
176 Beds
2 Full Service Emergency Departments
365 Affiliated Physicians
Specialities
Cancer Care Center
Digestive Care Center
Cardiology Care Center
Neuroscience / Stroke Care Center
Orthopedics including Spine Joint
Replacement Surgery
Womens Health
Bariatric Surgery
Clinical Laboratory
Total Lab Employees
89
Core Lab
Days 4 Techs
Evenings 4 Techs
Nights 2 Techs
ED Lab 1 Tech
Workload
Laboratory Testing
1.2 million CPT billables
annually
20% inpatient testing
80% outpatient testing
PutontheBrakes!!!!
XT-2000iV(XT-V)
Additional Core Lab
analyzer
Specifically for
Veterinary sample
Size Matters
Footprint
XN 1000 Footprint 25.4 x 33.7 x 29.7
XN-2000 - Footprint 37.8x 33.7 x 29.7
+1 IPU
+ 2 IPU
+ 2 IPU
+ 2 IPU
XN-2000: 37.8
2 x LH 500: 50.2 (+25%)
2 x DxH 800: 60 (+37%)
2 x LH 750: 78 (+52%)
Size Matters
Reagent Management
Standardization Share reagents
Inventory Space Saving
Smaller packaging
Concentrated reagent for the RU
Reagent Management
Use of concentrated
reagents RU-20
RFID barcodes for better
reagent management
Onboard reagent log
Color coded reagents
Easy to identify and
change
Clean, neat, easy storage
Size Matters
Sample Aspiration Volumes
Old analyzer 250L
XN-2000 - 88L
Manual back
position
Opentube
Sampler(rack)
Closedtube
10
Operational Efficiencies
Easy to use
IPU organization and icons
Compact Automation
Benefits of automation for the smaller user
Load Balancing
Onboard Rules
11
Efficient QC Management
Fewer files to manage
Tri-level QC for all reportable hematology tests
2-level BFQC for all reportable parameters
12
Efficient QC Management
Multi-module overlay
Automated IQAP system - Insight
Automatic transmission of data after analysis
Prompt access to peer data via internet
Efficient QC Management
Documentation of out-of-range
points
Within IQAP system
On-board XN software
13
Sysmex XN Technology
RBC,
PLT,
Hgb
WNR
WDF
NEW
NEW
RET
PLT-F
NEW
WNR Channel
BASO
Granulocyte
NRBC
MONO
LYMPH
Virtually eliminates
interferences from
Lyse resistant RBCs
Lipids
Maximize efficiency
Improves turnaround time
RBC
Debris
14
WDF Channel
Enhanced Flagging
Better detection of Platelet
Clumps
Atypical LYMPH
MONO
ImmatureWBC
Improved efficiencies
Rapid TAT
LYMPH
EO
NEUT
Decreased manual
interventions
Analysis Time extended to 3 times the Whole Blood WBC count time
15
PLT-F Channel
Second, reportable,
method of platelet
enumeration
RBC
IPF
PLT
PLT-F Channel
Fluorescent Dye specific for
platelet organelles
RBC
IPF
PLT
16
RET Channel
RET
LFR
RBC
MFR
HFR
IRF
Reportable
parameters
%/# Retic
IRF
RETHe
PLT
Reticulocyte Channel
Operational Efficiency
WBCs
Howell Jolley Bodies
Parasites
Sickle cells
17
Pleural fluid
Peritoneal fluid
MO-BF
LY-BF
PMN
NE-BF
Synovial fluid
EO-BF
Training
2 Techs for XN School
e-learning
Made techs feel like they were included
18
True back up
Standardization between Core & ED Lab
Compact automation
Decreased aspiration volume
Single Aspiration Pathway
Onboard / Automatic reflex testing
Ease of QC Management
Clinical Benefits
Improved turn-around times
Especially for the Infusion Center
19
Questions
20