DESCRIPTION
®
The 10 SEER Series condensing unit is the outdoor part of a
versatile system of air conditioning. It is designed to be cus-
tom-matched with one of UPG’s complete line of evaporator
sections, each designed to serve a specific function. Match-
ing air handlers are available for upflow, downflow, or hori-
zontal applications to provide a complete system. Electric
heaters are available if required. Add-on coils are available
for use with upflow, downflow, or horizontal furnaces and air
handlers.
TECHNICAL GUIDE
WARRANTY
5-year limited parts warranty.
SPLIT-SYSTEM 5-year limited compressor warranty.
AIR CONDITIONERS
FEATURES
10 SEER • QUALITY CONDENSER COILS - The coil is constructed
AM012M102 THRU AM030M1021 of enhanced copper tube and aluminum fins.
(1 THRU 2.5 NOMINAL TONS, 1 PH) • COIL PROTECTION - Coils are protected from damage by
a polymer mesh applied between the coil face, and a PVC
coated steel coil guard.
• PROTECTED COMPRESSOR - Recip compressors are
internally protected against high pressure and tempera-
ture. This is accomplished by the simultaneous operation
of high pressure relief valve and a temperature sensor
which protects the compressor if undesirable operating
conditions occur. A liquid line filter-drier further protects the
compressor.
• DURABLE FINISH - The cabinet is made of pre-painted
steel. The pre-treated flat galvanized steel provides a bet-
ter paint-to-steel bond, which resists corrosion and rust
creep. Special primer formulas and matted desert sand fin-
ish insure less fading when exposed to sunlight.
• LOWER INSTALLED COST - Installation time and costs
are reduced by easy power and control wiring connec-
tions. The unit contains enough refrigerant for matching
indoor coils and 15 feet of interconnecting piping. The
small base dimension means less space is required on the
ground or roof.
• TOP DISCHARGE - The warm air from the top mounted
fan is blown up away from the structure and any landscap-
ing. This allows compact location on multi-unit applica-
tions.
• LOW OPERATING SOUND LEVEL - The upward air flow
carries the normal operating noise up away from the living
area. The rigid top panel effectively isolates any motor
sound. Isolator mounted compressor and the rippled fins
of the condenser coil muffle the normal fan motor and
compressor operating sounds.
ER
TI
FI
ED T O ARI
AS
C
• LOW MAINTENANCE - Long life permanently lubricated
C

motor-bearings need no annual servicing.


O

AIR
M

-C
ER

PL
ON

Y
MA N U F A C T U R

RY

NI
D
TA

IT
OI

G W IT H
UN I

NI N G

R
• EASY SERVICE ACCESS - Fully exposed refrigerant con-
EQ
U I P M EN T
nections and a single panel covering the electrical controls
F
C

RT
O
E

IF NS
A I CA T IO
RI T S EC
I ON 10
S T A NDA R D 2
make for easy servicing of the unit.
LISTED
This product was manufactured Certification applies only
in a plant whose quality system when the complete
is certified/registered as being system is listed • SECURED SERVICE VALVES - Secured re-usable ser-
in conformity with ISO 9001. with ARI. vice valves are provided on both the liquid and vapor
sweat connections for ease of evacuating and charging.
Due to continuous product improvement, specifications
• U.L. AND C.U.L. LISTED - Approved for outdoor applica-
are subject to change without notice.
tion.
Visit us on the web at www.york.com for the most
Certified in accordance with the Unitary Small Equipment cer-
up-to-date technical information.
tification program, which is based on ARI Standard 210/240.
Additional rating information can be found at
www.ariprimenet.org.

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE


036-21573-001 Rev. A (0304)

Physical and Electrical Data


MODEL AM012M1021 AM018M1021 AM024M1021 AM030M1021
Unit Supply Voltage 208-230V, 1φ, 60Hz
Normal Voltage Range 1 187 to 252
Minimum Circuit Ampacity 8.8 10.1 15.3 19.3
Max. Overcurrent Device Amps 2 15 15 20 25
Compressor Type Rotary Recip Recip Recip
Rated Load 6.7 7.7 11.5 14.7
Compressor Amps
Locked Rotor 33 48 60 73
Crankcase Heater No No No No
Fan Motor Amps Rated Load 0.5 0.5 0.9 0.9
Fan Diameter Inches 17-1/2 17-1/2 17-1/2 17-1/2
Rated HP 1/12 1/12 1/8 1/8
Fan Motor Nominal RPM 1,100 1,100 1,075 1,075
Nominal CFM 1,600 1,550 1,750 1,750
Face Area Sq. Ft. 7.22 7.22 7.22 7.94
Coil Rows Deep 1 1 1 1
Fins / Inch 14 16 20 20
Liquid Line OD 3/8 3/8 3/8 3/8
Vapor Line OD 5/8 5/8 5/8 3/4
Unit Charge (Lbs. - Oz.) 3 3-2 3-1 3-4 3-9
Charge Per Foot, Oz. 0.66 0.66 0.66 0.68
Operating Weight Lbs. 94 114 119 122

1. Rated in accordance with ARI Standard 110, utilization range “A”.


2. Dual element fuses or HACR circuit breaker.
3. The Unit Charge is correct for the outdoor unit, matched indoor coil, and 15 feet of refrigerant tubing. For tubing lengths other
than 15 feet, add or subtract the amount of refrigerant, using the difference in length multiplied by the per foot value.

All dimensions are in inches. They are subject to change without


notice. Certified dimensions will be provided upon request.

C Refrigerant
Unit Dimensions
Connection
Model (Inches)
Line Size
A1 B C Liquid Vapor
012 22 21-3/4 21-3/4 3/8” 5/8”
018 22 21-3/4 21-3/4 3/8” 5/8”
A 024 22 21-3/4 21-3/4 3/8” 5/8”
030 24 21-3/4 21-3/4 3/8” 3/4”
1. Including Fan Guard

2 Unitary Products Group


036-21573-001 Rev. A (0304)

Additional R-22 Charge / Orifice Size for Various Matched Systems


ADDITIONAL R-22 CHARGE / ORIFICE SIZE FOR VARIOUS MATCHED SYSTEMS
Outdoor Unit AM012M1021 AM018M1021 AM024M1021 AM030M1021
Unit Orifice (s) 1 47 51 59 63
Factory R-22 Charge, lbs-oz 3-2 3-1 3-4 3-9

Indoor Coil Coil Orifice 2 System Orifice - Additional Charge, Oz


G2FD024(S,H)14/17 61 47 + 8 51 + 7 59 + 2 —
G2FD030(S,H)17 65 — — — 63 + 2
G2FD035(S,H)14 65 — — — 63 + 1
G1HD024 59 47 + 7 53 + 6 59 + 3 —
G1HD036 69 — — — 63 + 7
G1FA/G1UA024S14/17 59 47 + 6 51 + 5 59 + 0 —
G1FA/G1UA030S14 65 — — — 63 + 3
G1FA/G1UA036S14 73 — — 59 + 6 63 + 3
G1FA/G1UA03617/21 73 — — — 63 + 1
G1NA024S17G 51 47 + 0 51 + 0 — —
G1NA030S17H 57 — — 59 + 2 —
G1NA030S17K 63 — — — 63 + 2
G1NA030S21B 57 — — 59 + 2 —
G1NA030S21M 63 — — — 63 + 2
G1NF024SOF 63 — — 59 + 2 63 + 0
F2RP/F2FP018 53 47 + 3 51 + 1 — —
F2RP/F2FP024 61 — 51 + 7 59 + 2 —
F2RP/F2FP030 65 — — — 63 + 2
F2RP/F2FP036 75 — — — 63 + 8
MDD30BSD 57 — — 59 + 2 —
MDD30MSD 63 — — — 63 + 2
FOOTNOTES:

1. These orifices are packed in the customer packet of each outdoor unit.
2. These orifices are factory mounted in the flow control device of each indoor coil.
PROCEDURES:
1. Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaportor, and 15 feet of inter-
connecting line tubing.
2. Verify the orifice size and additional charge required for specific evaportor coil in the system using the above table.
3. Add charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified in the table above.
4. Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for
evaportor + adder for line set.
5. If the orifice in the evaportor was changed, verify the evaportor nameplate has been marked with the correct orifice size.

Unitary Products Group 3


036-21573-001 Rev. A (0304)

COOLING CAPACITY - With Air Handler Coils


AIR HANDLER COOLING
UNIT MODEL COIL1 NET MBH
ELECTRIC2 RATED SEER SEER
MODEL W MODEL EER
HEAT KW CFM TOTAL SENS. W/O TXV + TXV3
1 PH 10 SEER AC WITH N1AH / G2FD
AM012M1021 N1AHB0806 10 17 G2FD024(S,H)17 450 14.5 10.4 10.00 - 10.00
AM018M1021 N1AHB0806 10 17 G2FD024(S,H)17 650 18.6 13.4 10.00 - 9.50
AM024M1021 N1AHB0806 10 17 G2FD024(S,H)17 850 23.4 16.8 10.00 - 9.15
AM030M1021 N1AHB1206 10,15,18 17 G2FD030(S,H)17 1050 28.2 20.3 10.00 - 9.00
1 PH 10 SEER AC / F2RP 4,5
AM012M1021 F2RP018 2,5,8 18 - 500 14.5 10.6 10.00 - 9.70
AM018M1021 F2RP/F2FP018 2,5,8 18 - 650 17.4 12.6 10.00 - 9.35
AM018M1021 F2RP/F2FP024 5,8,10 18 - 650 18.6 13.4 10.00 - 9.50
AM024M1021 F2RP/F2FP024 5,8,10 18 - 850 23.4 16.8 10.00 - 9.15
AM030M1021 F2RP/F2FP030 5,8,10,15 18 - 1050 28.4 20.3 10.00 - 9.05
AM030M1021 F2RP/F2FP036 5,8,10,15,19 21 - 1050 29.0 20.7 10.00 - 9.15
Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210/240.
Cooling MBH based on 95°F outdoor ambient, 80°F entering air temperature, 50% RH, and rated air flow.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power input in
watt-hours during the same period.

1. G2FD coils available with a factory installed horizontal drain pan. See price pages for specific model number.
2. Single phase units require single phase 2HK heaters.
3. TXV = Use 1TV700 Series Kit.
4. To meet R=4.2 insulation requirements, substitute F2FP for F2RP. All ratings remain the same.
5. F2RP air handlers have B.O.D (Blower on Delay) standard.
- = Not applicable.

ACCESSORIES* 1H/1C, auto/manual changeover, electronic programmable,


deluxe 7-day, thermostat.
Refer to Price Manual for specific model numbers.
1H/1C, auto/manual changeover, electronic programmable.
Hard Start Kit - Provides increased starting torque for areas
with low voltage. * For the most current accessory information, refer to the
price book or consult factory.
Compressor Blanket - Designed to further reduce the nor-
mal compressor operating sound. Refer to price pages for SOUND RATINGS*
specific match-ups. SOUND
Off Cycle Timer Delay - Provides a 5-minute off cycle to pre- UNIT MODEL RATINGS
vent rapid recycling of the compressor. DBA
012 72
Room Thermostats - A wide selection of compatible thermo-
018 74
sets are available to provide optimum performance and fea-
024 75
tures for any installation.
030 76
1 Heat Stage only, manual, mechanical thermostat. Add sub- *Rated in accordance with ARI Standard 270.
base for 1H/1C.
1H/1C, manual change-over electronic non-programmable
thermostat.

4 Unitary Products Group


036-21573-001 Rev. A (0304)

COOLING CAPACITY - Upflow, Downflow, & Horizontal Furnaces and Coils


FURNACE1 COOLING
COIL
UNIT MODEL CFM RANGE NET MBH SEER
W MODEL RATED CFM SEER + TXV2 EER
(MIN.-MAX.) TOTAL SENS. W/O TXV
14,17 G1FA024S14,17 450 14.4 10.3 10.00 - 9.95
- G1HD024 450 14.6 10.4 10.00 - 10.00
250
AM012M1021 17 G1NA024S17G 450 14.1 10.0 10.00 - 9.80
650
14,17 G1UA024S14,17 450 14.4 10.3 10.00 - 9.95
14,17 G2FD024(S,H)14,17 450 14.5 10.4 10.00 - 10.00
14,17 G1FA024S14,17 650 18.3 13.3 10.00 - 9.40
- G1HD024 650 18.5 13.5 10.00 - 9.50
575
AM018M1021 17 G1NA024S17G 650 17.7 12.4 10.00 - 9.50
725
14,17 G1UA024S14,17 650 18.3 13.3 10.00 - 9.40
14,17 G2FD024(S,H)14,17 650 18.6 13.4 10.00 - 9.50
14,17 G1FA024S14,17 850 23.0 16.6 10.00 - 9.05
14 G1FA036S14 850 23.8 17.2 10.00 - 9.25
- G1HD024 850 23.6 17.0 10.00 - 9.25
750 17 G1NA030S17H 850 23.6 16.5 10.00 - 9.20
AM024M1021
950 21 G1NA030S21B 850 23.6 16.5 10.00 - 9.20
14,17 G1UA024S14,17 850 23.0 16.6 10.00 - 9.05
14 G1UA036S14 850 23.8 17.2 10.00 - 9.25
14,17 G2FD024(S,H)14,17 850 23.4 16.8 10.00 - 9.15
14 G1FA030S14 1050 28.2 20.2 10.00 - 8.95
14 G1FA036S14 1050 28.2 20.2 10.00 - 8.95
17,21 G1FA036S17,21 1050 28.0 20.0 10.00 - 8.95
- G1HD036 1050 28.4 20.2 10.00 - 9.00
17 G1NA030S17K 1050 28.4 19.9 10.00 - 9.00
925
AM030M1021 21 G1NA030S21M 1050 28.4 19.9 10.00 - 9.00
1175
14 G1UA030S14 1050 28.2 20.2 10.00 - 8.95
14 G1UA036S14 1050 28.2 20.2 10.00 - 8.95
17,21 G1UA036S17,21 1050 28.0 20.0 10.00 - 8.95
17 G2FD030(S,H)17 1050 28.2 20.3 10.00 - 9.00
14 G2FD035(S,H)14 1050 28.0 20.0 10.00 - 8.95
1. Refer to Quick Selection Chart for specific furnace match-up.
2. TXV = Use 1TV700 Series Kit.

COOLING PERFORMANCE
SUCT. T/P @ AIR TEMP ON CONDENSER SUCT. T/P @ AIR TEMP ON CONDENSER
MODEL COMPR. 75°F 95°F 115°F MODEL COMPR. 75°F 95°F 115°F
TEMP. PSIG MBH KW MBH KW MBH KW TEMP. PSIG MBH KW MBH KW MBH KW
35 61.5 13.1 1.01 11.6 1.20 10.1 1.40 35 61.5 21.0 2.23 17.0 2.46 14.2 2.63
40 68.5 14.5 1.03 12.8 1.23 11.2 1.44 40 68.5 22.9 2.24 19.3 2.52 16.5 2.74
AM012M1021 AM024M1021
45 76.0 15.9 1.04 14.1 1.26 12.4 1.47 45 76.0 25.0 2.27 21.6 2.58 18.3 2.83
50 84.0 17.4 1.06 15.5 1.28 13.6 1.51 50 84.0 26.8 2.28 23.9 2.63 20.5 2.92
35 61.5 16.2 1.66 13.1 1.84 11.0 1.96 35 61.5 25.1 2.68 20.3 2.97 17.0 3.17
40 68.5 17.7 1.67 14.9 1.88 12.8 2.04 40 68.5 27.4 2.70 23.1 3.04 19.7 3.30
AM018M1021 AM030M1021
45 76.0 19.3 169 16.7 1.92 14.2 2.11 45 76.0 29.9 2.74 25.8 3.10 21.9 3.41
50 84.0 20.8 1.70 18.5 1.96 15.9 2.18 50 84.0 32.1 2.75 28.6 3.17 24.5 3.51

NOTES:
1. For condensing unit only. Does not include effect of evaporator motor power or heat.
2. Performance based on 15° superheat and 15° sub-cooling at condensing unit.
a. Increase capacity 1% for each 2° increase in sub-cooling.
b. Decrease capacity 1% for each 2° decrease in sub-cooling.
3. Sub-cooling in excess of 20° may result in excessively high condensing temperature with air on condenser above 115°F.
Maximum recommended condensing temperature is 140°F.

Unitary Products Group 5


036-21573-001 Rev. A (0304)

TYPICAL INSTALLATION

THERMOSTAT
TO FURNACE OR
AIR HANDLER
TERMINAL BLOCK
MINIMUM 18” SERVICE ACCESS
CLEARANCE ON ONE SIDE
WEATHERPROOF NEC CLASS 1 WIRING
DISCONNECT NEC CLASS 2 WIRING
SWITCH
60” OVERHEAD
CLEARANCE

TO INDOOR COIL

6” CLEARANCE
AROUND PERIMETER

SEAL OPENING(S) WITH


PERMAGUM OR EQUIVALENT
NOTE: ALL OUTDOOR WIRING
MUST BE WEATHERPROOF. CONTROL
ACCESS PANEL

TYPICAL FIELD WIRING


ALL FIELD WIRING TO BE IN ACCORDANCE WITH NATIONAL ELECTRIC CODE (NEC) AND/OR LOCAL CODES
POWER WIRING
POWER WIRING
208-230, 1f, 60 Hz CONTROL WIRING
24 VOLT CONTROL WIRING
MINIMUM 18 GA. WIRE FACTORY WIRING
(NEC CLASS 2)
FURNACE OR AIR HANDLER TERMINAL BLOCK

C Y R G W
* TERMINAL W IS ONLY
REQUIRED ON SYSTEMS
WITH HEAT.

CONTACTOR
TERMINALS

GND. COIL *
LUG Y R G W

CONDENSING UNIT ROOM THERMOSTAT

ALL OUTDOOR WIRING MUST BE WEATHERPROOF. USE COPPER CONDUCTORS ONLY.

6 Unitary Products Group


036-21573-001 Rev. A (0304)

COOLING PERFORMANCE DATA


AIR CONDITIONER MODEL NO. AM012M1021
INDOOR COIL MODEL NO. G1NA024S17G
CONDENSER ID CFM 400 450 500
ENTERING AIR ID DB (°F) 85 80 70 85 80 70 85 80 70
TEMPERATURE ID WB (°F) 72 67 57 72 67 57 72 67 57
T.C. 15.4 14.6 13.8 15.4 14.7 14.0 15.5 14.8 14.2
75 S.C. 9.6 9.6 9.2 10.0 9.9 9.7 10.3 10.3 10.2
K.W 1.21 1.21 1.21 1.23 1.22 1.22 1.25 1.24 1.24
T.C. 15.2 14.2 13.1 15.3 14.4 13.3 15.4 14.6 13.6
85 S.C. 9.8 9.5 9.0 10.1 10.0 9.5 10.5 10.4 10.1
K.W 1.32 1.31 1.31 1.34 1.33 1.33 1.36 1.35 1.35
T.C. 15.1 13.8 12.4 15.2 14.1 12.7 15.3 14.4 13.0
95 S.C. 9.9 9.5 8.8 10.3 10.0 9.3 10.7 10.5 9.9
K.W 1.43 1.42 1.42 1.45 1.44 1.44 1.47 1.46 1.46
T.C. 14.2 13.0 11.6 14.3 13.2 11.9 14.5 13.4 12.1
105 S.C. 9.5 9.0 8.3 10.0 9.6 8.8 10.5 10.1 9.4
K.W 1.56 1.55 1.53 1.58 1.57 1.55 1.60 1.59 1.57
T.C. 13.3 12.1 10.9 13.5 12.2 11.1 13.6 12.4 11.2
115 S.C. 9.2 8.6 7.7 9.8 9.1 8.3 10.4 9.7 8.9
K.W 1.69 1.67 1.65 1.71 1.70 1.67 1.73 1.72 1.69
T.C. 12.5 11.3 10.2 12.6 11.3 10.3 12.8 11.3 10.4
125 S.C. 8.8 8.1 7.2 9.5 8.7 7.8 10.2 9.2 8.4
K.W 1.82 1.80 1.76 1.84 1.82 1.78 1.86 1.85 1.81
NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.

Multipliers for determining the performance with other indoor sections.


NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.

Air Handler Coil T.C. S.C. KW


N1AHB0806 G2FD024(S,H)17 1.03 1.04 1.01
F2RP018 1.03 1.06 1.04
G1FA024S14,17 1.02 1.03 1.01
G1HD024 1.04 1.04 1.01
G1UA024S14,17 1.02 1.03 1.01
G2FD024(S,H)14,17 1.03 1.04 1.01

Unitary Products Group 7


036-21573-001 Rev. A (0304)

COOLING PERFORMANCE DATA


AIR CONDITIONER MODEL NO. AM018M1021
INDOOR COIL MODEL NO. G1NA024S17G
CONDENSER ID CFM 500 650 800
ENTERING AIR ID DB (°F) 85 80 70 85 80 70 85 80 70
TEMPERATURE ID WB (°F) 72 67 57 72 67 57 72 67 57
T.C. 20.6 19.1 17.8 20.7 19.5 18.3 20.9 19.9 18.8
75 S.C. 11.3 11.1 10.8 12.0 12.0 12.1 12.7 13.0 13.4
K.W 1.59 1.58 1.56 1.66 1.64 1.63 1.72 1.71 1.70
T.C. 19.7 18.2 16.5 19.9 18.6 17.1 20.1 19.0 17.7
85 S.C. 11.3 10.9 10.4 12.3 12.2 11.8 13.4 13.5 13.2
K.W 1.70 1.68 1.66 1.77 1.75 1.73 1.84 1.82 1.80
T.C. 18.9 17.3 15.2 19.1 17.7 15.9 19.4 18.0 16.5
95 S.C. 11.3 10.8 9.9 12.6 12.4 11.5 14.0 13.9 13.0
K.W 1.81 1.79 1.76 1.88 1.86 1.83 1.95 1.92 1.90
T.C. 17.4 15.5 13.5 17.7 16.0 14.1 18.1 16.6 14.7
105 S.C. 10.7 10.0 9.2 12.4 11.7 10.8 14.0 13.4 12.3
K.W 1.92 1.88 1.84 1.99 1.95 1.91 2.06 2.02 1.98
T.C. 15.9 13.7 11.8 16.4 14.4 12.4 16.9 15.1 12.9
115 S.C. 10.2 9.2 8.5 12.1 11.1 10.1 14.0 12.9 11.6
K.W 2.02 1.96 1.92 2.09 2.04 1.99 2.17 2.12 2.06
T.C. 14.4 11.9 10.1 15.0 12.8 10.6 15.7 13.7 11.1
125 S.C. 9.7 8.4 7.8 11.8 10.4 9.4 14.0 12.4 10.9
K.W 2.12 2.05 1.99 2.20 2.13 2.07 2.28 2.22 2.15
NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.

Multipliers for determining the performance with other indoor sections.


NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.

Air Handler Coil T.C. S.C. KW


N1AHB0806 G2FD024(S,H)17 1.05 1.08 1.05
F2RP/F2FP018 0.98 1.02 1.00
F2RP/F2FP024 1.05 1.08 1.05
G1FA024S14,17 1.03 1.07 1.04
G1HD024 1.05 1.09 1.05
G1NA024S17G 1.00 1.00 1.00
G1UA024S14,17 1.03 1.07 1.04
G2FD024(S,H)14,17 1.05 1.08 1.05

8 Unitary Products Group


036-21573-001 Rev. A (0304)

COOLING PERFORMANCE DATA


AIR CONDITIONER MODEL NO. AM024M1021
INDOOR COIL MODEL NO. G1NA030S17H
CONDENSER ID CFM 650 850 1050
ENTERING AIR ID DB (°F) 85 80 70 85 80 70 85 80 70
TEMPERATURE ID WB (°F) 72 67 57 72 67 57 72 67 57
T.C. 28.0 26.3 23.9 28.3 26.6 24.7 28.5 27.0 25.5
75 S.C. 15.5 15.3 14.6 16.9 16.9 16.5 18.3 18.4 18.5
K.W 2.25 2.21 2.17 2.34 2.30 2.26 2.42 2.39 2.35
T.C. 26.6 24.5 22.5 26.9 25.1 23.1 27.2 25.7 23.7
85 S.C. 15.4 14.8 13.9 17.0 16.7 15.9 18.7 18.5 17.8
K.W 2.39 2.33 2.28 2.48 2.43 2.38 2.57 2.53 2.47
T.C. 25.1 22.8 21.0 25.5 23.6 21.5 25.9 24.4 21.9
95 S.C. 15.2 14.4 13.1 17.1 16.5 15.2 19.0 18.6 17.2
K.W 2.53 2.46 2.39 2.63 2.57 2.50 2.72 2.68 2.60
T.C. 23.1 20.7 18.5 23.5 21.5 19.1 24.0 22.2 19.7
105 S.C. 14.4 13.6 12.4 16.5 15.7 14.4 18.6 17.8 16.3
K.W 2.73 2.64 2.57 2.84 2.75 2.67 2.94 2.85 2.77
T.C. 21.0 18.6 16.1 21.5 19.3 16.8 22.0 19.9 17.5
115 S.C. 13.7 12.8 11.7 16.0 14.9 13.5 18.3 16.9 15.4
K.W 2.93 2.81 2.75 3.04 2.92 2.84 3.16 3.03 2.94
T.C. 19.0 16.5 13.6 19.5 17.1 14.5 20.1 17.7 15.3
125 S.C. 13.0 12.1 11.0 15.5 14.1 12.7 18.0 16.1 14.4
K.W 3.12 2.99 2.92 3.25 3.10 3.02 3.38 3.21 3.11
NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.

Multipliers for determining the performance with other indoor sections.


NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.

Air Handler Coil T.C. S.C. KW


N1AHB0806 G2FD024(S,H)17 0.99 1.02 1.00
F2RP/F2FP024 0.99 1.02 1.00
F2RP/F2FP024 0.79 0.00 0.76
G1FA024S14,17 0.97 1.01 0.99
G1FA036S14 1.01 1.04 1.00
G1HD024 1.00 1.03 0.99
G1NA030S17H 1.00 1.00 1.00
G1NA030S21B 1.00 1.00 1.00
G1UA024S14,17 0.97 1.01 0.99
G1UA036S14 1.01 1.04 1.00
G2FD024(S,H)14,17 0.99 1.02 1.00

Unitary Products Group 9


036-21573-001 Rev. A (0304)

COOLING PERFORMANCE DATA


AIR CONDITIONER MODEL NO. AM030M1021
INDOOR COIL MODEL NO. G1NA030S17K
CONDENSER ID CFM 850 1050 1250
ENTERING AIR ID DB (°F) 85 80 70 85 80 70 85 80 70
TEMPERATURE ID WB (°F) 72 67 57 72 67 57 72 67 57
T.C. 32.8 31.3 29.0 33.2 31.8 29.9 33.7 32.3 30.7
75 S.C. 19.6 19.4 19.2 20.4 20.5 20.5 21.3 21.7 21.9
K.W 2.75 2.72 2.68 2.85 2.81 2.78 2.94 2.90 2.87
T.C. 31.3 29.5 27.1 31.9 30.1 27.9 32.5 30.6 28.7
85 S.C. 19.2 19.0 18.6 20.4 20.2 20.0 21.6 21.5 21.3
K.W 2.95 2.89 2.83 3.05 2.99 2.93 3.15 3.08 3.03
T.C. 29.9 27.7 25.3 30.6 28.4 26.0 31.2 29.0 26.7
95 S.C. 18.9 18.5 18.0 20.4 19.9 19.4 21.9 21.3 20.7
K.W 3.14 3.06 2.98 3.24 3.16 3.09 3.35 3.27 3.20
T.C. 27.9 25.6 22.9 28.6 26.2 23.6 29.3 26.9 24.4
105 S.C. 18.1 17.6 16.9 19.7 19.0 18.4 21.3 20.5 19.8
K.W 3.32 3.22 3.12 3.43 3.33 3.23 3.54 3.44 3.34
T.C. 25.9 23.4 20.5 26.6 24.1 21.3 27.4 24.9 22.1
115 S.C. 17.4 16.7 15.7 19.0 18.2 17.3 20.6 19.7 19.0
K.W 3.50 3.37 3.27 3.61 3.49 3.38 3.72 3.60 3.49
T.C. 23.8 21.3 18.1 24.6 22.0 19.0 25.5 22.8 19.8
125 S.C. 16.7 15.7 14.6 18.3 17.3 16.3 20.0 18.9 18.1
K.W 3.67 3.53 3.42 3.79 3.65 3.53 3.91 3.77 3.64
NOTE: ALL CAPACITIES ARE NET WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.

Multipliers for determining the performance with other indoor sections.


NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the
listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.

Air Handler Coil T.C. S.C. KW


N1AHB1206 G2FD030(S,H)17 0.99 1.02 0.99
F2RP/F2FP030 1.00 1.02 0.99
F2RP/F2FP036 1.02 1.04 1.00
G1FA030S14 0.99 1.02 1.00
G1FA036S14 0.99 1.02 1.00
G1FA036S17,21 0.99 1.01 0.99
G1HD036 1.00 1.02 1.00
G1NA030S21M 1.00 1.00 1.00
G1UA030S14 0.99 1.02 1.00
G1UA036S14 0.99 1.02 1.00
G1UA036S17,21 0.99 1.01 0.99
G2FD030(S,H)17 0.99 1.02 0.99
G2FD035(S,H)14 0.99 1.01 0.99

10 Unitary Products Group


036-21573-001 Rev. A (0304)

MATCHING INDOOR COMPONENTS

ADD-ON COILS - FOR FURNACE APPLICATIONS

G1UA G1NA
1/2 CASED G1HD UNCASED
UPFLOW HORIZONTAL DUCT UPFLOW

G2FD*
MULTI-POSITION
G1FA
(UPFLOW, HORIZONTAL
FULL CASED
AND DOWNFLOW)
UPFLOW

* Available with factory installed horizontal drain pan.

AIR HANDLERS - FOR NON-FURNACE APPLICATIONS

N-AH OR N-VS
MODULAR BLOWER
(UPFLOW, HORIZONTAL
AND DOWNFLOW)

G+FD
COIL
F+RC / F+FC OR
F+RC / F+FP
FAN COIL UNITS
(UPFLOW, HORIZONTAL)

Unitary Products Group 11


NOTES

Subject to change without notice. Printed in U.S.A. 036-21573-001 Rev. A (0304)


Copyright © by York International Corp. 2004. All rights reserved. Supersedes: Nothing