Before starting a project, the Wall designer, Project, and Engineering, settings should be set or checked,
and modified if necessary. This will save time later.
Wall designer, Project settings, and Engineering Environment settings, will default to the settings that
were saved with the project when an existing project is opened. If a new project is opened, the Wall
Designer, and Project settings defaults, will be set to the last project opened. The Engineering
Environment will have all settings deleted, and open as a blank file.
The Wall designer settings contain the default settings that will be used when using the Wall Designer
mode.
These defaults may be changed at any stage during the drawing of walls, and the new settings will
become the defaults for any future work done. They do not affect anything already drawn.
Walls.
Defaults.
WIDTH. This is the default width, (thickness of the wall), that walls will be built.
CLADDING THICKNESS. This is the total thickness of any cladding, which is to be added to the wall
framing. This does not include the framing, but does include any cavity such as in brick work.
Naming
PREFIXES. These are the prefixes, which will apply to each panel type.
The numbering sequence of Joists, Supports, and Truss Layouts, will remain in the order they were
created, but the prefix can be changed at any stage to begin a new prefix group. If a prefix is changed,
the Rename All button will become active. If it is clicked, all previous panels in that group will be re
named to the new prefix.
When the Rename All button is clicked a warning will appear.
Note If it is intended that the walls will be renamed later in the project, when they have been finally
cut, and just before they are edited, select a wall prefix that is different from the final one so the final
prefix will be available later.
If walls are cut in Wall Designer, the second wall created, will take on the next number in the normal
numbering sequence.
If walls are cut in Project, the second wall created will become part a of the original wall.
Renaming the walls will cause the walls cut in project, to adopt the numbering sequence they were
created in.
Colours.
This displays the default colour of the display of Hidden, Position Locked, and Other, walls in wall
designer. To change the colour, click on the desired wall type.
If a new colour is selected part way through a project, the project will revert to the new colour.
Openings.
Openings Database
OPENINGS DATABASE. This displays the Openings Database file address. The software is designed to
operate from this address for networking purposes.
The openings database, is a user defined database of openings sizes and descriptions, which can be
accessed through the window and door openings tools, and also through individual opening properties
while creating a project.
Multiple data bases can be created, to accommodate different clients requirements.
The file address will show the current default openings database. In the example below the default is
called Openings
Clicking on the open folder will display the location of the various openings data files, and display the
openings data files available.
In the example, there are 3.
Openings,
Client 1 openings,
Client 2 openings
Selecting a different openings database file, and clicking Open, will change the default to the new file.
In the example below, Client 2 has been selected.
Clicking Edit, will open the default openings data base for editing.
CODE. This is the descriptive code that identifies the database entry. This code only will appear in the
openings code windows.
DESCRIPTION. This is a user reminder of the openings description.
WIDTH. This is the actual width the opening will be created in mm.
HEIGHT. This is the actual height that the opening will be created in mm.
L HEADER SIDE. L Headers can be entered as part of an opening properties. Clicking in the L Headers
Side box produces a menu.
L HEADER. If a L Header side has been selected, an entry from the L Header data base can be selected
to become part of the opening properties. Clicking in the L Headers box produces a menu,
Individual entries can be shifted, by selecting them, and then using the, Move up, and Move down,
buttons.
Entries can be deleted by selecting them, and clicking the, Delete button.
Additional entries can be made by clicking the, Add button.
The window will move to the bottom of the list, and display a new entry space.
Existing entries can be altered by, selecting the field to be altered, and typing a new value.
Note. Any alteration to the openings Database must be saved.
Make the new entries, or modify existing ones, and then click the Save button.
Give the new database file a new name. In the example above, Manual Demo, and click the Save
button.
The new database file will be created in the C:\Program Files (x86)\SCS\Design, folder.
NOTE. Ensure that the correct openings database file has been selected as the default.
The default openings can be selected from the Data base by opening the Openings section of Wall
Designer settings and clicking on the menus at the side of the Code boxes.
The openings code list will appear where the desired selection can be made.
The default openings will now have the properties of the selection.
When the Insert window opening and Insert door opening tools are selected, the default opening
properties will display.
These can be altered if necessary, by clicking the menu arrow, and selecting another opening code.
All openings in that sequence will be inserted to the new code, but the default has not been changed.
To return to the default, select another tool, and then re select the opening tool.
Existing openings can be altered by double clicking an opening to display its properties,
All openings of one code, can be collectively replaced by openings of another code, by opening the
Openings section of Wall designer settings and clicking Find and replace
In the example the windows in walls 2, 3, and 4, have the code W1212., and they will be replaced by
code W1512. The larger window in Wall 1 which has a different code will not be affected.
Using the menu arrows, select the code of the existing windows to be replaced in the Openings to find
window, and select the replacement code in the Replace with window.
Click the Replace button, and ALL openings that were code W1212 will be replaced by code W1512
openings.
The number of openings replaced will be reported.
If Selected only is checked, openings will be replaced with the new size as they are selected.
Special openings.
Special openings can be created that do not match Data base entries. These can be created as the
Default or as individual openings. These will adopt the title of Current entries and will not form part of
the Data base. Current entry openings cannot be changed using the Find and Replace function.
Note. The thickness of the bucking is not automatically added to the steel opening size. The opening
size must be adjusted accordingly.
Bucking
The bucked property of an opening, is represented by a darkening of the inside face of the opening
members.
A Bucking code can be printed on the frame prints by clicking on the Code menu arrow, and selecting a
code from the menu.
The code selected in the example is a description of the buck material to be used in Imperial.
Checking Flatten Bucked Doors will cause the tray lips to be flattened next to the base of door
opening studs, to allow full width bucks to be inserted into the bottom track.
Checking Notched Doors will place a notch, adjacent to the opening studs to ease the removal of the
bottom track at door openings.
This may affect the stability of the bottom track during transportation and erection.
Note. The notches at door openings will be placed adjacent to the opening stud, and will not be placed
correctly if full width bucking is added, and the bottom track is to extend to the inside of the bucking.
Warning. Door notches are out of joint functions, and their positions are controlled by a measurement
from the start end of the bottom track. If the start end of the track is lengthened or shortened, it will
move the door notch positions. Unless the door notches are placed at the base of the opening studs, they
do not display, there for if they are moved out of position, they will not show in design, but will still be
sent to the roll former.
Before modification of start end stud.
Notches
The remedy is to leave the bottom track at its original length, and trim it after the panel is assembled.
L-Headers
SIDE
The placement of L-Headers is determined by selecting either None, Near, Far, or Both, from the menu.
Near, is the nearest side, when the orientation dot is on the left end of the frame.
CODE
The code displayed on the L-Headers can be selected from the menu.
EDIT
Clicking Edit will give access to the L-Header, Strapping, Bracing, and Bucking data bases for
modification,
L-Headers.
Strapping,
Bracing,
Bucking,
Floor Levels.
The Floor Level section, sets the default height of the walls at each level, and the height above 0 that
the bottom of the walls at each level will be created, and the distance allowed at each level for joists and
flooring.
The wall base height is greyed out because this distance is calculated by the software according to the
entries made in the other boxes.
Note. Walls and joists copied from one level to another will retain the properties of the original level
copied from. They must be selected and have their set files altered to reflect the properties of the new
level.
Level.
This lists the 5 levels that are available.
Joist Depth.
This is the default depth of the floor joist at each level. The joists at each level are at the base of the
walls on that level.
The walls at level 1 will have their base at 0, and if a slab floor is to be used, any joist depth, and
flooring thickness, set for this level will be ignored.
Note Joists drawn at each level, will be drawn at the Joist Depth set for that level. Joists copied from
another level will retain the depth of the level they were drawn on, and must be selected and have their
properties altered to the new depth.
Flooring Thickness.
This is the thickness of the flooring material, (if it extends under the walls), that will be placed on top of
the joists to form the floor. If a slab floor is to be used, at level 1, any flooring thickness, set for this level
will be ignored. Flooring laid between the walls will have its thickness set to 0 and allowance made for
it in the wall height.
Wall Base.
This is the distance above 0 that the bottom of the walls for that level will be created. This distance is
automatically calculated by the software.
The base of the walls at level 1 is set at 0 in the software.
Stud height.
This is the default stud height at each level.
Note Walls drawn at each level, will be drawn at the stud height set for that level. Walls copied from
another level will retain the height of the level they were drawn on, and must be selected and have their
properties altered to the new height
Shadow
Setting the Shadow level in multi storey construction, allows a selected level to be shadowed behind the
level being worked on. (Active level). Walls on the active level can be automatically snapped to align with
the appropriate wall of the shadow level, provided the shadow level wall is within the snap range.
Any other level, above or below, may be selected to shadow the active level.
A level may not shadow itself.
The same level may be set to shadow all levels except itself.
Level 1.
Level 2
Before starting a project, set the joist depth, floor thickness, and stud height for each level. The
software will calculate the wall base height for each level.
Checking Lock Base Heights will then lock the wall bases to these heights.
Individual walls, or groups of walls can be created at a different height at any level, by altering the Stud
Height of that level. Because the wall bases are locked, the software will not recalculate the wall base
height.
Individual walls, or groups of walls, can still have their heights changed by selecting them and altering
their properties.
Un-checking Lock Base Heights will cause the software to recalculate to the current values, and any
further joists and walls drawn, will be created at the new settings.
Dimensioning.
The Dimensioning defaults, gives viewing and positioning options for dimensions.
When a wall is selected.
If the Show wall length box is checked, the length of the wall selected will display.
If the Show parallel wall distances box is checked, the distances between the selected wall and
the nearest parallel walls either side of the selected wall will display.
Select the required option for the dimensioning from, Face-to-face or Centre-to-centre.
Openings
When an opening is selected, its inside and outside distance from the nearest wall and the end of the
structure are displayed. If the Outside distance to centre, and Inside distance to centre options are
not checked the default will show the distances to the outsides of the openings. Checking either or both
boxes will cause the distances to be displayed to the centre of the opening.
When the Show opening dimensions box is checked, the sizes of all openings are displayed.
Outside dimensions
When the, Show outside dimensions box is checked, as the walls are drawn outside dimensions of the
structure will be displayed.
Options for displaying Dimension origin lines, and Wall width dimensions are also activated.
The example shows both the origin lines and wall width dimensions chosen.
Clicking on the dimension position to be altered in the right hand graphic, will highlight the measurement
to be adjusted.
Distance
Dimension
Snap Settings.
When the Align Wall Ends box is checked, any selected wall that is moved to within the snap range of
an existing parallel adjacent wall, will snap to that wall.
Snap to Wall.
The Snap to wall setting, is the maximum distance the cursor may be clicked from a wall to have the
cursor controlled function, (drawing a dimension line, or a wall,) snap to that wall.
The Snap to wall setting also controls the maximum distance the cursor views when selecting.
Snap to angle.
The Snap to Angle, STANDARD setting, gives a range of angles that walls will snap to when being
drawn.
For projects where walls are either vertical or horizontal, a high snap setting (Say 45) makes drawing
easier, and the snap setting can be changed to draw in angled walls.
The Snap to Angle, CUSTOM setting, allows custom angles to be entered.
When Custom is selected ONLY the set angles will be adopted, therefore if 0deg, 90deg, or any
standard angles are to be used, they must also be entered.
Settings can be changed between Standard and Custom at any stage in the drawing process but any
wall then moved, will snap to the nearest angle in the active selection.
The reciprocal angle to the ones specified will automatically be allowed, so that walls may be drawn from
either end.
Custom angles are set using the layout below. Only angles between 0 and 180 need to be entered.
Angles can be entered to the nearest 1/10th of a degree. IE. 18.2
Negative angles can be entered. The program will convert these to positive angles.
Grid.
The entries are greyed out unless the show Grid box ix checked.
The grid only displays in Wall Designer.
Show Grid.
The show grid check box turns on and off the display of the grid.
Snap to Grid.
Checking Snap to Grid will cause the walls to snap to the grid lines as they are drawn, provided they
are within the snap range.
Walls will snap with the grid lines as their centre line.
X Gridlines.
Y Gridlines.
These settings alter the layout of the gridlines along the X and Y axes.
The gridline layout can be altered part way through a project. Walls that were snapped to the original
layout will remain in their original position.
Colour.
The colour of the gridlines can be altered by clicking on the colour example,
Project Settings.
Project settings will default to the settings that were saved with the project when an existing project is
opened. If a new project is opened, the defaults will be set to the last project opened.
Project settings are accessed through, File, and select Project Settings from the Menu.
General.
This tab allows the setting of sundry general values.
Units
This sets the program to either Metric or Imperial units. The project can be opened at any time in either
Metric or imperial units.. The setting is changed using the menu arrow.
Note. Changing between Metric and Imperial, and back to metric, can cause a slight change in the
Metric default values, due to rounding. If this situation has arisen, it is advisable to check the defaults.
None.
This setting will automatically create an auto recovery file (In SDP) format, at the interval specified, (In
the example, 10 minutes), and each time the project is saved manually.
This file is automatically created by default, in Documents and Settings Log in Name Local
Settings. in the Temp folder Each new file overwrites the old one. The files are automatically deleted
when the program is exited normally.
If the program should be unusually terminated during use, when it is re opened, a dialog box will appear,
asking if you want to open the last auto recovery file.
Note. Auto recovery files are deleted, when the file is closed. The Load Auto Recover Project will
appear if a second version of ScotSteel is opened. To open a second, different project, click NO.
If 2 projects are open, an Auto Recovery file will be saved for each. Only 1 will prompt to open. The
other will need to be manually accessed.
Auto save.
This setting will save the project at the set intervals. ( In the example, 10 minutes.)
Each save will overwrite the previous one.
If a new project has not been named, the first Auto save will ask for the file to be named, and saved in
its correct location.
Plate Depths.
These settings control the sizes at which the Plates, Bracing, and Strapping will display. The settings
can be altered at any time during the project, and any change will affect only future insertions. Once
inserted, the display depth cannot be altered. If incorrect, they must be deleted, the default depth
changed, and re inserted.
L-Headers. The L-Headers settings box allows for a default setting, which sets the depth of L-Headers
that are inserted, with or without a code.
Adjacent to the L-Headers settings box is a quick access button to the L-Headers database.
Quick
access
button
Clicking on the quick access button will display the L-Headers database.
To set a Default L-Header, select the L-Header code from the Default L-Header menu. To access the
menu, Click on the Menu arrow.
When a L-Header is inserted, a Confirmation box will appear, displaying the default L-Header code.
This may be changed by selecting another code from the menu. (This will not change the default)
L-Header codes, and the length of the L-Header, will display on the frame prints.
These are the amounts by which the plane edges in each group will shift, (either in or out), when the
Plane Edge Adjust tool is used.
Edge to be moved
Select here
Left clicking on the Edge adjust tool will cause the edge to reduce by the set amount.
Holding down the Ctrl key and left clicking on the Edge Adjust tool will cause the edge to extend by
the set amount.
The Edge Adjust default can be altered for the plane type being viewed, by right clicking on the Edge
Adjust tool.
A text box will appear where the existing setting is displayed. A new setting can be entered. Changing
this setting will alter the default in the General window.
Prefixes.
These settings establish the prefixes for the roof and ceiling frame names.
These settings set the width that the Trusses in a Truss layout, and the Joists will be created.
The example shows joists set to wall machine width. If floor trusses are to be used the setting should be
altered to the width of the trusses which is 68mm.
Checking Centreline Stud Alignment will cause the base of the tray to align with the centre of the
Truss/Support/Joist, when Truss align, Support Align, or Joist Align, in the wall properties are
checked.
Unchecked, will cause the base of the tray to align with the edge of the flange of the Truss.
(This will place the rivet approx under the centre)
The edge of the truss does not appear to align with the base of the stud, because where the truss sits on
the plate it is 40mm wide, but the truss is represented in the project as 68mm wide. (Overall the lips).
Truss
represented as
68 wide in
project
14mm
Actual width of
the base of the
section 40mm
Wall Plate
Stud 38
Truss dimension
to Lip
Reverse Zoom
Checking Reverse Zoom, will cause the zoom direction on the scroll wheel to be reversed.
Checking these will produce the webs on panel and truss 3D views and printouts, and dotted flange lines
on roof trusses.
Panel.
Truss.
Checking Show Frame labels will display the frame labels in Project view. This does not affect the
Wall Designer view display.
Checking Show Axes will display the reference axes in the RH bottom corner of the display window.
Reference
Axis
Altering the Zoom Speed slide, will alter the rate of zoom.
Project.
The Project section contains settings to include project information, and graphics, on Printouts.
Graphics files can be saved as Bitmap, GIF, or Jpeg files, and stored in
C:\Program Files\SCS\Design\Project Graphics.
The project information is saved with the job, and will appear on all printouts if the Print Project Details
box is checked..
By default Project Information is positioned in the bottom RH corner of 3D view, and Screen view,
and as a heading on the Steel report.
In Print frame group, and Print frame detail by group, the position of the Project information is at the
setting position of the Project info graphic. (The top one listed)
The Graphics are not saved with the job. The will appear on Print frame group and Print frame detail
by group, only, and will be at the settings set in Project Settings Project at the time of the print.
Checking Print Project Details will print the project details entered, on printouts.
Project Information.
Graphics controls
The Project Info Graphic can be printed as either a banner above, or a background behind the project
information.
Banner
Background
Additional Graphics.
Frames.
The set files folder displays the file address of the various panel set files.
Clicking the open folder on the right, will display the file path to that address.
The example shows the original Default, and 3 user created Set files, Default 140, Default 90, and Zero
Thickness.
Alter the various settings as described below, and click on the Save icon.
The set file folder of the selected panel type, (In the example Walls) will appear, listing the set files
already created. (In the example there is only 1 [default]), and a text box where the file name for the
new set file can be entered, (In the example Manual Demo).
Click Save and the new set file will be added to the data base.
Ceiling.
Frame Items
Miscellaneous
This setting is the clearance allowed between all back to back members in a ceiling frame. Settings of
1/10 mm are allowed EG. 2.6
This setting is used by the program, to calculate the required reduction in the length of a member, when
it enters another at an angle. EG. lattice members
The 400 series profile has a 38mm flange.
The 500 series profile has a 46mm flange.
The 700 series profile has a 38mm flange.
Edge Adjustment.
This is the clearance automatically allowed at the junction and the edges of the ceiling frames.
Thickness.
This is the width of the tray. EG. 63, 70, 76, 90, 140.
Note. If the structure does not have a ceiling, the ceiling thickness must be set to 0.
Items Locked.
When a panel or plane is selected, and their properties viewed, the lock status will display.
Locking a ceiling plane before the panel is created in project, will prevent the panel from being created.
Unlocking the panel or the plane in its properties will unlock the panel.
User Group.
This box can display the user code of the user group the panels may be associated with. The menu
arrow, gives access to the user defined data base of user groups codes and their associated description.
To view the entries in the data base, click on the menu arrow.
The user defined name of the frames chosen for the selected user group is displayed in the panel below.
(Setting up the data base is covered further in the chapter under User Groups)
Frame description .
This area will display the entries above, when the default set files are being created.
During a project, when a frame is selected and its properties viewed, under the Misc tab the square
area of the frame, the quantity of steel used in the frame, and the weight of the frame, will display, if a
weight has been selected from the database.
Export to RF
By default, Export to RF will be checked. Un-checking Export to RF will convert the frame to the Non
RF category, and the frame will not be sent to the roll former for production.
This enables frames to be created to represent non frame entities. These frames can be coloured
differently to represent their function in the project.
Colour Pallet.
Clicking on the Colour Pallet icon, will display the Colour Pallet.
Brace Pitch.
This is the brace pitch angle for any K bracing placed into the ceiling panel.
Horizontal
Even spread.
This option places the horizontal items (Nogs) evenly spaced within the available space, to a maximum
spacing of the amount set. In the example, 1200mm.
In raked frames, the spacing is calculated from the highest part of the frame.
Fixed Spread.
Special Note. ScotSteel displays, and only measures from the flat face of C sections. Allowance must
be made for the orientation and width of the flanges when the frame is required for edge fixing of linings.
This option places the first horizontal from the bottom at a set height. In the example 600.
The second at a set height above the first. In the example 800.
And the remainder set at the fixed spacing specified. In the example 1000.
Alternate spacing.
Checking Alternate spacing will place the horizontals at alternate heights, with the amount of difference
specified in the setting box. In the example 50mm.
Minimum Length.
Setting a length in the text box causes the program to automatically delete any horizontal nog, that
length or shorter to be deleted.
VERTICAL.
Even Spread.
Selecting this setting will place the verticals evenly spaced, at a spacing no greater than the Max set. (In
the example 600.
Fixed spread.
Special Note ScotSteel displays, and only measures from the flat face of C sections. Allowance must
be made for the orientation and width of the flanges when the frame is required for edge fixing of linings.
This will place the first vertical at the 1st spacing from the end of the frame, and all other verticals at the
Other spacing,
Doubles.
Engineering.
Gauge Weight.
This displays the code of the tray width, wall height, gauge and tensile strength of the tray section. The
menu arrow gives access to the data base of other available profiles and tensile strengths.
To view the entries in the database, click on the menu arrow.
(Setting up, and using the data base, is covered further in the chapter under Weights)
Joists
Frame Items.
Miscellaneous
Joist Separation.
Joists are spaced across the floor plane at the fixed spacing set in the Joist Separation setting
The measurement is a centre to centre spacing.
Note. The last joist at the edge of the plane will not be formed, and must be manually drawn.
Section wall height.
This setting is used by the program, to calculate the required reduction in the length of a member, when
it enters another at an angle.
The 400 series profile has a 38mm flange.
The 500 series profile has a 46mm flange.
The 700 series profile has a 38mm flange.
End Adjustment.
User Group.
This box displays the user code of the user group the panels will be associated with. The menu arrow,
gives access to the user defined data base of user groups codes and their associated description.
The description of the frames chosen for the selected user group is displayed in the panel below.
To view the entries in the data base, click on the menu arrow.
(Setting up the data base is covered further in the chapter under User Groups)
Frame description .
This area will display the entries above, when the default set files are being created.
During a project, when a joist is selected and its properties viewed, under the Misc tab the square area
of the joist, the quantity of steel used in the joist, and its weigh will display.
Export to RF
By default, Export to RF will be checked. Un-checking Export to RF will convert the frame to the Non
RF category and the frame will not be sent to the roll former for production.
This enables frames to be created to represent structural steel items, ducting etc. These frames can be
coloured differently to represent their function in the project.
Colour Pallet.
Clicking on the Colour Pallet icon, will display the Colour Pallet.
Depth.
The default joist depth setting for each individual floor level is taken from Wall Designer Settings,
Levels
When Joists are selected, and their properties viewed, the depth setting for those joists will display. This
setting can be altered, to alter the depth of the selected Joists.
Brace Pitch.
This is the default pitch of the lattice members in the joist.
Engineering.
Gauge Weight.
This displays the code of the tray width, wall height, gauge and tensile strength of the tray section. The
menu arrow gives access to the data base of other available profiles and tensile strengths.
To view the entries in the database, click on the menu arrow.
(Setting up, and using the data base, is covered further in the chapter under Weights)
Plate Type.
Number of Plates
Plate thickness
Restraint Spacing.
These entries are in preparation for the Joist Engineering, and are not active at this time.
Roof.
MISCELANEOUS.
Back to back separation.
This setting is the clearance allowed between all back to back members in a roof frame. Settings of 1/10
mm are allowed EG. 2.6
Section wall height.
This setting, is used by the program to calculate the required reduction in the length of a member, when
it enters another at an angle.
The 400 series profile has a 38mm flange.
The 500 series profile has a 46mm flange.
The 700 series profile has a 38mm flange.
End Adjustment.
Thickness.
This is the width of the tray. EG. 63, 70, 76, 90, 140.
Items Locked.
When a panel or plane is selected, and their properties viewed, the lock status will display.
Locking a ceiling plane, before the panel is created in project, will prevent the panel from being created.
Unlocking the panel or the plane in its properties will unlock the panel.
User Group.
This box displays the user code of the user group the panels will be associated with. The menu arrow,
gives access to the user defined data base of user groups codes and their associated description.
The description of the frames chosen for the selected user group is displayed in the panel below.
To view the entries in the data base, click on the menu arrow.
When a User Group has been selected, a description of the frames in that group will display.
(Setting up the data base is covered further in the chapter under User Groups)
Frame description .
This area will display the entries above, when the default set files are being created, or if a Gauge /
Weight has not been allocated to a selected frame.
During a project, when a frame is selected and its properties viewed, under the Misc tab the square
area of the frame, the quantity of steel used in the frame, and the weight of the frame, will display.
Export to RF
By default, Export to RF will be checked. Un-checking Export to RF will convert the frame to the Non
RF category and the frame will not be sent to the roll former for production.
This enables frames to be created to represent structural steel items, ducting etc. These frames can be
coloured differently to represent their function in the project.
Colour Pallet.
Clicking on the Colour Pallet icon, will display the Colour Pallet.
Brace Pitch,
This sets the brace pitch of any K bracing put into the roof panel.
Horizontal
Even spread.
This option places the horizontal items (Nogs / purlins) evenly spaced within the available space, to a
maximum spacing of the amount set. In the example, 900mm.
In raked frames, the spacing is calculated from the highest part of the frame.
Fixed Spread.
Special Note ScotSteel displays, and only measures from the flat face of C sections. Allowance must
be made for the orientation and width of the flanges when the frame is required for edge fixing of linings.
This option places the first horizontal from the bottom at a set height. In the example 600
The second at a set height above the first. In the example 800.
And the remainder set at the fixed spacing specified. In the example 1000.
Alternate spacing.
Checking Alternate spacing will place the horizontals at alternate heights with the amount of difference
specified in the setting box. In the example 50mm.
Minimum Length.
Setting a length in the text box causes the program to automatically delete any horizontal nog, that
length or shorter to be deleted.
To delete short nogs in hip roof panels the setting can be set higher than for other panels.
Minimum length set at 120.
VERTICAL.
Even Spread.
Selecting this setting will place the verticals evenly spaced, at a spacing no greater than the Max set. (In
the example 900.
Fixed spread.
Special Note ScotSteel displays, and only measures from the flat face of C sections. Allowance must
be made for the orientation and width of the flanges when the frame is required for edge fixing of linings.
This will place the first vertical at the 1st spacing from the end of the frame (800), and all other verticals
at the Other spacing (900).
Doubles.
Engineering.
Gauge Weight.
This displays the code of the tray width, wall height, gauge and tensile strength of the tray section. The
menu arrow gives access to the data base of other available profiles and tensile strengths.
To view the entries in the database, click on the menu arrow.
(Setting up, and using the data base, is covered further in the chapter under Weights)
Support.
Miscellaneous.
Back to back separation.
This setting is the clearance allowed between all back to back members in a support frame. (except
double lintel plates which have a separate setting) Settings of 1/10 mm are allowed EG. 2.6.
(
Section wall height.
This setting is used by the program, to calculate the required reduction in the length of a member, when
it enters another at an angle.
The 400 series profile has a 38mm flange.
The 500 series profile has a 46mm flange.
The 700 series profile has a 38mm flange.
End Adjustment.
User Group.
This box displays the user code of the user group the panels will be associated with. The menu arrow,
gives access to the user defined data base of user groups codes and their associated description.
The description of the frames chosen for the selected user group is displayed in the panel below.
To view the entries in the data base, click on the menu arrow.
When a User Group has been selected, a description of the frames in that group will display.
(Setting up the data base is covered further in the chapter under User Groups)
Frame description .
This area will display the entries above, when the default set files are being created, or if a Gauge /
Weight has not been allocated to a selected frame.
During a project, when a frame is selected and its properties viewed, under the Misc tab the square
area of the frame, the quantity of steel used in the frame, and the weight of the frame, will display.
Export to RF
By default, Export to RF will be checked. Un-checking Export to RF will convert the frame to the Non
RF category and the frame will not be sent to the roll former for production.
This enables frames to be created to represent structural steel items, ducting etc. These frames can be
coloured differently to represent their function in the project.
Colour Pallet.
Clicking on the Colour Pallet icon, will display the Colour Pallet.
Lintel height.
This setting is the height the lattice lintel will occupy in the support frame.
Setting of 400.
Brace pitch.
50 deg setting.
70 deg setting.
Checking this box will instruct ScotSteel to use a single lattice lintel plate.
For structural reasons the programme will also default to an Aligned lintel , where the jack studs align
with the apexes of the lattice.
Unchecked, the program constructs a lintel with double C sections at the top of the lintel. And jack
studs set to the Stud layout.
Lintel Gap.
The stud gap setting is used with double lintel plates, and 0 lintel height, to space the studs evenly
across the support frame with a maximum spacing of the setting entered. ( in the example 600mm)
This setting is not used with a single lintel plate, because the studs will align with the apexes of the
lattice triangles.
Engineering.
Gauge Weight.
This displays the code of the tray width, wall height, gauge and tensile strength of the tray section. The
menu arrow gives access to the data base of other available profiles and tensile strengths.
To view the entries in the database, click on the menu arrow.
(Setting up, and using the data base, is covered further in the chapter under Weights)
Walls.
The LH side display shows the various categories of settings available in the Panel type.
Lintels
Lintel Height.
This is the vertical height of lattice that will be created within the clear space available above an opening.
The lintel Height may be set to a greater height than the space available. The amount added to the
available space should be limited to a maximum of 20mm, because a greater excess will cause the lintel
to form incorrectly.
Available Space 400mm.
Lintel height set to 415.
Brace pitch
This setting determines the angle the web members will be placed at in a lattice beam or lintel.
The Brace pitch angle can be altered by using the increase and decrease arrows, or entering another
value.
Setting 60
Setting 50
Unchecked, the program constructs a lintel with double C sections at the top of the lintel. And jack
studs set to the Stud layout.
Checking this box will instruct ScotSteel to use a single lattice lintel plate instead of the back to back set
as the default.
For structural reasons the programme will also default to an Aligned lintel , where the jack studs align
with the apexes of the lattice.
Checking the Lintel jack studs box will insert a jack stud, back to back with the opening stud, to provide
additional support for the bottom lattice member, and to provide a stronger joint to the top lattice
member if the lattice is not full height. (These jacks should be Tek screwed to the opening stud after the
Standard Lintel
Reduced lintel
Note. If Facing double studs is checked, or the opening requires triple studs, Lintel Jack Studs
cannot be used with Extend multi Stud lintels, because the first full stud at the side of the opening will
face toward the opening, the same way as the Lintel Jack.
A warning will display when both Lintel Jack Studs, and Extend Multi Stud Lintels are checked, to
warn of the potential conflict.
Top lintel
Checking Top Lintel will cause the lattice section of the lintel to be placed at the top of the lintel.
Note. If single lintel plate is selected, the jacks will still align with the top nodes of the lattice.
This will not cause a joint conflict, but will limit the magnitude of any load hung from the top of the
opening.
Lintel Gap.
MISCELANEOUS.
This setting is the clearance allowed between all back to back members in a wall frame. (except double
lintel plates which have a separate setting) Settings of 1/10 mm are allowed EG. 1.6.
Section wall height.
This setting is used by the program, to calculate the required reduction in the length of a member, when
it enters another at an angle. EG. lattice lintels.
The 400 series profile has a 38mm flange.
The 500 series profile has a 46mm flange.
The 700 series profile has a 38mm flange.
End Adjustment.
User Group.
This box can display the user code of the user group the panels may be associated with. The menu
arrow, gives access to the user defined data base of user groups codes and their associated description.
To view the entries in the data base, click on the menu arrow.
The user defined description of the frames chosen for the selected user group, is displayed in the panel
below.
(Setting up the data base is covered further in the chapter under User Groups)
Frame description .
This area will display the entries above, when the default set files are being created.
During a project, when a frame is selected and its properties viewed, under the Misc tab the square
area of the frame, the quantity of steel used in the frame, and the weight of the frame, will display, if a
weight has been selected from the database.
Export to RF
By default, Export to RF will be checked. Un-checking Export to RF will convert the frame to the Non
RF category, and the frame will not be sent to the roll former for production.
This enables frames to be created to represent non frame entities. These frames can be coloured
differently to represent their function in the project.
Colour Pallet.
Clicking on the Colour Pallet icon, will display the Colour Pallet.
Engineering often requires double or triple studs to be placed at each side of wall openings.
Double gap
The Dbl gap setting is the distance the second stud is placed from the opening stud. The example shows
100mm
Usually engineering requires only openings above a certain width to have double studs. The Double
opening limit setting is the minimum width of opening that double stud openings will apply to.
Facing double studs.
The default is for double opening studs to face the same way.
If required, the double opening studs can be created to face each other by checking the Facing double
studs box.
Usually engineering requires only openings above a certain width / stud height to have triple studs. The
Triple opening limit setting is the minimum width of opening that triple stud openings will apply to.
The above example shows settings that will provide single stud openings up to 1250mm, Double opening
studs from 1251mm to 2000mm, and Triple opening studs above 2000mm.
Extend Multi Stud Lintels.
Checking Extend Multi Stud Lintels will only affect double or triple stud openings. It will cause the lattice
lintel to pass over the opening stud, and extend to the second opening stud.
Note. If Facing double studs is checked, or the opening requires triple studs, Lintel Jack Studs
cannot be used with Extend multi Stud lintels, because the first full stud at the side of the opening will
face toward the opening, the same way as the Lintel Jack.
A warning will display when both Lintel Jack Studs, and Extend Multi Stud Lintels are checked, to
warn of the potential conflict.
HORIZONTAL
Even spread.
This option places the horizontal items (Nogs) evenly spaced within the available space, to a maximum
spacing of the amount set. In the example, 700mm.
In raked frames, the spacing is calculated from the highest part of the frame.
Fixed Spread.
Special Note ScotSteel displays, and only measures from the flat face of C sections. Allowance must
be made for the orientation and width of the flanges when the frame is required for edge fixing of linings.
This option places the first horizontal from the bottom at a set height. In the example 600.
The second at a set height above the first. In the example 800.
And the remainder set at the fixed spacing specified. In the example 1000.
Alternate spacing.
Checking Alternate spacing will place the horizontals at alternate heights, with the amount of difference
specified in the setting box. In the example 50mm.
The lower horizontal will be placed at the horizontal setting set.
Minimum Length.
Setting a length in the text box causes the program to automatically delete any horizontal nog, that
length or shorter, to be deleted.
VERTICAL.
Even Spread.
Selecting this setting will place the verticals evenly spaced between the fixed members of the frame.
(Openings, Partitions etc.), at a spacing no greater than the Max set. (In the example 600.)
Fixed spread.
Special Note ScotSteel displays, and only measures from the flat face of C sections. Allowance must
be made for the orientation and width of the flanges when the frame is required for edge fixing of linings.
This will place the first vertical at the 1st spacing from the end of the frame, and all other verticals at the
Other spacing, ignoring fixed verticals, (Openings, Partitions etc.),
This setting is suitable where verticals are set to exterior sheet sizes.
Truss Align
When Truss Align is checked, a settings box appears next to it, where a max setting can be entered.
Studs will be aligned below the truss layout according to whether Centreline Stud Alignment is
checked (in Project Settings General) with a maximum spacing as set in Max
Example.
If the trusses are at 900 centres and the max setting is 1000.
If the trusses are at 900 centres and the max setting is 600.
A vertical will be placed centrally between the trusses. Any area beyond the trusses will have the
verticals evenly spaced at a maximum of 600 centres.
Support align
When Support Align is checked, a settings box appears next to it, where a max setting can be entered.
Studs will be aligned below the supports on the same level, according to whether Centreline Stud
Alignment is checked (in Project Settings General) with a maximum spacing as set in Max
In the example, the studs will align with the supports, and the spaces between will have studs spaced at
even spacing no greater than 600.
Support Aligned
Wall
Joist align,
When Joist Align is checked, a settings box appears next to it, where a max setting can be entered.
Studs will be aligned below the joists according to whether Centreline Stud Alignment is checked (in
Project Settings General) with a maximum spacing as set in Max
Note. The studs on level 1 will align with the joists on level 2.
Doubles.
If Doubles is checked, all verticals not concerned with openings and partitions, will be doubles.
When a frame is selected, its origin (start end) can be identified by a green rectangle.
Small,
Medium.
Large.
Any change to set files, and certain planar changes require the panel to be rebuilt for the change to take
effect.
Checking the Confirm rebuild after changing properties box will cause the program to show a prompt if
the required rebuild is not instructed.
Most walls will have wall joint studs to provide fixing for interior linings, therefore the box is checked.
Wall joint
Studs
If these studs are not required, uncheck the Wall Joint Studs box.
Sometimes a frame is created that has a perimeter item that is too short for the system to construct
properly.
The Min perimeter item length setting prompts the software to warn when a perimeter item of the set
length or shorter has been created, when the Wall plan and frame test is performed.
.
Corner braces can be inserted into frames to aid their stability during transportation and erection.
The corner brace distance is the horizontal or vertical distance to the centre of the brace. In the example
300.
Engineering.
Gauge Weight.
This displays the code of the tray width, wall height, gauge and tensile strength of the tray section. The
menu arrow gives access to the data base of other available profiles and tensile strengths.
To view the entries in the database, click on the menu arrow.
(Setting up, and using the data base, is covered further in the chapter under Weights)
Roof.
The Roof tab contains the default settings that roof planes will be built to.
Note. Select the type of roof to be created FIRST. Other settings in the Roof section will alter to reflect
the roof type selected.
Pitch,
This is the roof angle in Degrees.
If the roof slope has been specified as a gradient (EG. 5 in 12 ) it can be automatically converted to the
pitch angle by clicking on the Calculate button.
A text box appears where the gradient is entered.
Soffit.
This is the horizontal distance of the soffit overhang.
Actual
panel
overhang
Plane Soffit
width
Because the top face of the roof panel protrudes beyond the roof plane it is often desirable to reduce the
soffit by the amount of the protrusion.
This can be automatically calculated and allowed for by checking the Soffit reduction for vertical fascia,
box.
The amount of the reduction is displayed. In the example 25deg pitch with a 90mm roof panel requires a
reduction of 38mm.
This is now Automatically allowed, when the roof planes are built.
Note. Soffit Reduction for Vertical fascia, would not be used with trusses, because the trusses are
created below the roof plane.
Gable overhang.
Setting a cantilever allows the truss heel to be placed anywhere between the wall line and the fascia line.
The software automatically raises the roof planes to the correct height for the cantilever setting.
Example. 600 soffit. 0 cantilever, 110 heel height.
300 cantilever.
600 cantilever.
Support
frame
Soffit reduction
for vertical fascia
Note. Cantilevering panel roofs may require the addition of a support frame at the plate line, to prevent
loading the ceiling overhang.
The Truss heel height is primarily used to set the heel height for a truss roof.
The truss heel height is the distance from the top of the top chord, to the bottom of the bottom chord, at
the outside edge of the heel.
The heel height is pitch dependant, and must be set to a distance that prevents a collision between the
top and bottom chords
Truss
Heel
height
Avoid
collision
A general guide to truss heel heights is that 110 will suit pitches up to 25 deg, 115 will suit to 35 deg,
and 120 above 35 deg.
Entering 0 as a heel height will cause Truss Plus to create a joint without a vertical, and at the minimum
the pitch will allow.
This will create the top chord of the truss above the roof plane height, and the trusses in TrusPlus will
not correspond to the profile in ScotSteel.
Roof plane
height
Note. If Panel Roof or Hybrid Roof is selected, the heel height will be greyed out. In these options
the heel height is set by the thickness of the ceiling panels, the pitch of the roof, and with Hybrid, any
Purlin thickness entered, and is automatically calculated by the software.
The Level Stud height is display only, and will show the default stud height set in Wall Designer..
Floor Levels for the last level viewed in Wall Designer.
The auto roof speed slide, controls the rate at which the auto roof takes place.
Sometimes, with complicated roofs, the auto roof cannot cope with the final jointing of the planes at the
ridge.
Hitting the Esc key will stop the auto roof, and the planes can then be manually joined.
Type.
Note. Select the type of roof to be created FIRST. Other settings in the Roof section will alter to reflect
the roof type selected.
Purlin Thickness.
Purlin thickness is only active, when Hybrid Roof, has been selected.
Enter the Purlin thickness if required. The Purlin thickness is the square height of the Purlin. (In the
example 45 )
Purlin
Thickness
The Default Drop Type, only becomes active when, Truss Roof has been selected as Type.
Selecting the particular type of roof to be constructed, will display the truncated truss drop distance in
the, Drop Distance box.
The Drop Distance is automatically calculated using the pitch, Default Drop Type, and any Purlin
thickness if, Hybrid Roof is selected.
Note. Even though Truss Roof is selected as Type, the Panel Hybrid drop distance will display, if
selected. The only options that apply to Truss Roof are Extended Jack Top Chord, Extended Corner
Jacks, and No Jack Extensions.
Printing.
This tab contains the print settings for fonts, styles, scales, and spacing.
Print Preview.
Ticking the Print Preview box, will produce a print preview before each print, where the desired print
can be checked.
Scale.
Checking the Scale to fit box will scale the various prints to fit the page size selected.
Wall designer wall plans.
Print frame group will adopt the scale setting which will become available to alter when the scale to fit
box is unchecked.
50 to 1
150 to 1
Print Frame detail by group will print 1 frame per page, to the scale selected.
50 to 1
100 to 1
Font.
This section allows the setting and style of the print font.
(The screen font is set in the next tab)
Various fonts are available from the menu.
Checking Trusses in Detailed Frame Print. Will print the truss positions and the loads they apply to the
wall in a Print Frame detail By Group.
Note. The trusses must have passed through the engineering package to obtain the loads on the wall.
Example.
Selected
Wall
The trusses in the example above have been engineered, and their loads on the walls obtained.
Loads at
bearings 1
and 2
A Print Frame detail By Group. of the selected wall is shown below.
Truss positions
Truss loads in
Newtons
Checking Monochrome wall plans will print all Screen Views, in black and white.
Frame printing.
Frame separation.
This is the distance between frames in Print frame group Care must be taken when printing small
frames that sufficient distance is allowed between frames to accommodate the frame size printed below.
Line width.
This governs the print width of the lines.
The fill style is the hatch style of plates, L-Headers, braces etc,
Checking frame dimensions will print the OA dimensions of frames in Print frame group
Checking Plates / straps / braces, will display plates, straps, braces, etc on Print frame group
Margins.
These settings will control the margins around the frame prints and will vary with different printers.
When Print Frame detail By Group is selected, checking Two details per page will print 2 detailed
panels per page.
Note. The correct scale must be chosen to enable the panels to fit the page.
Font.
Checking this box will produce a white rectangle behind the frame dimensions, which can enhance the
clarity of the dimension.
Weights.
Data Base.
This section displays the data base of tray weights per gauge and width.
This data base is stored in C:\Program Files\SCS\Design (Weights.dat)
Note. The Weights section is being developed to process the sections specified by the engineering into
individual tray width, gauge, and tensile strength, specific files for the roll former.
The Gauge codes are not alterable. They are the same format that is used by the engineering, and after
development, will trigger a reminder at the roll former specifying the coil type that should be being run
for the panels in the file.
The number of entries in the data base can be reduced considerably, by deleting un-necessary entries.
See Delete row button, further in the section.
Altering the coil weights.
The coil weights have been established by SCS, based on the available coil. It is the users responsibility
to confirm these weights.
The weights are not alterable in the Weights tab, but can be altered by opening the Weights.dat file,
which is in C:\Program Files\SCS\Design, with Notepad.
The last section in the .dat file contains the coil weight entries.
The number after the = sign is the weight of the coil per metre.
The installed Weights.dat file contains all of the tray widths available in all tray thicknesses and tensile
strengths. Most of the entries will not apply to any individual operator, so the excess entries should be
deleted to eliminate confusion.
To delete an entry, select the row, and click the Delete Row button.
Warning. Each width and gauge, is listed in both G350 and G550 where applicable. Make sure the
correct entry is being deleted.
Multiple entries cannot be selected for deletion.
The Weights.dat file will be updated when the OK button is clicked.
Up/Down arrows.
These can be used to move any selected cell, up or down one place in the list.
More
Clicking the More button will access additional data bases of weights of,
L-Headers.
Strapping
Bracing,
and Bucking.
User Groups,
Services.
This section contains entries that control the display size, and positions of service holes that are placed in
frames, either, automatically, or by using the Add Services to the Frame tool.
Sizes
Service holes are displayed as rectangles, and the display size can be set by altering the width and height
settings. (This has no affect on the actual size punched)
The large service hole is only available on the 700 series Roll Formers. ( When a plumbing tool head is
fitted )
Positions.
These are the positions the small service holes will be punched in a frame, when the Add Services to the
Frame tool is used, or Add to all wall frames is checked.
Vertical Position
From base.
This is a list if the small service holes centre positions measured from the bottom of the frame in vertical
members. (In the example 400, 1100, and 2149)
Where the height of a service hole will place it through lattice members, solid braces, and jacks, the hole
will be inserted.
Horizontal Position.
From Start.
These are the positions from the start end of a frame, that a line of small service holes will be placed
vertically in a frame.
Braces.
Checking Braces, will place a small service hole in the centre of each brace member.
At Centre.
Checking At Centre will place a small service hole in the centre of each horizontal member, including
the perimeters.
Hide Services.
If large numbers of service holes are inserted into a project, considerable graphics resources will be used,
which will slow the display.
Checking Hide Service Holes prevents the service holes being displayed in the screen view. The service
holes will still be exported with the frames.
If the panels are to be filled with light weight concrete after assembly, checking the Use Notches
Instead box will cause all of the automatically inserted service holes listed in this tab, to be replaced with
notches. This enhances the ability to fill the wall.
Checking Add to all wall frames will automatically add small service holes, ( unless Use Notches
Instead is checked), to all future frames created, and any existing frame that is rebuilt.
Service holes will not be added to any frame created before Add to all frames is checked.
Note. If Add to all wall frames and Hide service holes are both checked, a warning will appear when
The Design program is first opened.
Note. Service holes can be added to existing frames without rebuilding, by selecting the frames in
Project view, and clicking the Add services to the frame tool on the left hand tool bar.
Trusses.
The trusses tab contains the profile size, truss spacing, snapping and naming settings for trusses.
The graphic shows where the truss profile measurements are taken from.
Truss spacing.
Is the default centre to centre spacing of the trusses.
Profile height
Is the height of the profile. Current roll formers produce a profile 52mm high.
Profile width.
Is the profile width overall the lips. Current roll formers produce a profile 68mm wide.
Flange width
Is the width of the top flange. (40mm)
Minimum Span.
Is the minimum length of the bottom chord, that the trusses will be created.
Attempting to create a truss with a shorter bottom chord, will cause the truss to be deleted.
Snaps.
When truss is
trimmed to
here, it will be
opposite J11
Truss being
drawn will snap
to opposite truss
Snap to ceiling.
Checking Snap to ceiling will cause any truss that is drawn parallel to, and within the snap range of a
ceiling edge, to snap to the ceiling edge. The centre of the truss will align with the ceiling edge.
The snap range is controlled by the slide next to snap to roof point. (This will only display when either
Snap to ceiling, or Snap to roof point is checked.)
Ceiling
edge
Truss being
drawn
Roof
point
Snap to Angle.
Truss being
drawn
Checking Snap to Angle will cause the trusses to snap to the standard or custom angles set in Wall
designer Settings Snap settings
Naming.
Girder.
Jack.
Corner Jack
Common
Saddle
Un-checking Truss kind naming will name the trusses with the prefix entered in the Truss naming
Prefix box, and in the order they were created.
Clicking the Rename all button will rename the existing trusses to the new prefix. A warning box will
appear confirming the rename.
If the prefix is changed, and Rename All is not clicked, all future trusses created will have the new
Prefix, and the numbering will begin again from 1.
Show distance to nearest ceiling line.
If Show distance to nearest ceiling line, is checked, when a truss is selected, it will display a
measurement from its centre, to the nearest ceiling line. This dimension may be selected to move the
truss.
ScotHelp.
Exporting.
ScotSteel only exports EP2 roll former files. ScotSteel is backwards compatible If an EP2 export file is
required from an old project, it can be opened in the latest ScotSteel and an EP2 file exported.
Special Note. If any difficulty is encountered opening an old SDP file to create an EP2 export, send the
INT, ENT, or EPF file to Scottsdale Construction Systems for an EP2 conversion.
DXF.
Text Size.
This allows for the text size if the DXF to be set.
Hole Size.
This sets the size of the orientation hole in the DXF.
Use rotated wall labels.
With Use rotated wall labels, unchecked, wall labels are orientated from the bottom.
With Use rotated wall labels, checked, wall labels are orientated from the inside.
CSV.
Checking the Net wall Areas box will include the net wall area of each panel in the CSV export.
Engineering Environment.
Engineering Environment settings, will default to the settings that were saved with the project when an
existing project is opened. If a new project is opened, the Engineering Environment will have all settings
deleted, and open as a blank file.
(On some systems, Excel will open and then automatically minimise. If this happens, click on the Excel
icon to maximise again)
A spreadsheet will open at the general properties, where the job name, a job number, job address the
name of the detailer, and the company the job is being done for, are entered.
The version number of the engineering software being used is also displayed.
Simplified Environments.
Simplified Environments, is designed to accommodate users conforming to Australian codes, who are
familiar with the use of the Steel Framing Systems manual, and must be used in accordance with the
criteria specified in that manual.
To ascertain what wind region to enter, refer to the Steel Framing Systems manual.
NOTE. Simplified environments are only allowed when certain criteria are met.
It is a Residential Building
The building has a maximum plan dimension of 16m
The building has a maximum roof pitch of 35 degrees
The limitation acceptance is confirmed by checking the confirmation boxes.
Note. The limitations listed above do not constitute the complete list. Refer to the Steel Framing
Systems manual for the full list of criteria.
Select the appropriate simplified environments wind region. (In the example N4)
If it is decided to abandon the simplified environments, and complete the custom environments, click the
Cancel and set-up custom environments button, and the software will return to the General screen.
To proceed with the simplified environments, Click, Proceed with Simplified Environments.
A warning will appear, stating that the chosen course may not be efficient,
To proceed, click OK and the software will go directly to the environment report section.
The software has populated the data fields with general values. Example, the wind screen below
If custom environments are to be entered, double Click Next and the first General Properties screen will
open.
Select the function of the proposed building. (In the example Residential Dwelling).
Number of Stories
Is Building Enclosed.
The above setting is a job setting. It covers the general condition created by the design of the structure.
Most buildings will be classed as enclosed, unless they are in cyclonic regions.
Special conditions governing the design of veranda roofs, attached carports, internal carports, etc. are
dealt with, by applying the necessary environmental factors to only the frames and panels concerned.
A building which has a number of significant, permanent openings in its perimeter, is classed as open.
In special circumstances, where there are smaller permanent openings in one wall only, consult an
engineer.
In Cyclonic regions, unless exterior cladding and windows meet certain impact resistance criteria laid
down in the code, the building must be considered as open. This is because possible damage from flying
debris, may break windows and/or cladding, turning the building from being enclosed, to open. Most
buildings in cyclonic regions will be classed as open.
Free standing carports, and structures with only one or two walls, are classed as canopies. The job
setting should be set to Open. The Canopy classification will be given to the panels on an individual
basis, and will override the job setting.
Clicking Yes will enter Enclosed
Roof Pitch.
The roof pitch must be entered in Degrees. Round pitches that contain decimals to the nearest whole
degree. (EG. 22.5 deg rounded to 22 deg)
For roofs with a single pitch, enter the pitch in both Max and Min boxes.
Buildings with multiple roof pitches, enter the highest pitch in the Max box, and the lowest pitch in the
Min box.
Roof Shape.
Building Width.
Building Length.
Length
Width
Do you need to apply a wind load to the building. The answer will normally be Yes. If No is clicked,
the software will move on to the first Snow screen.
If Yes is clicked,
and the design wind is known, click the top button. This will open a window where the Ultimate and
design service wind speeds can be entered.
Note. The DESIGN wind speed is the wind velocity that will be applied to the structure, after all
environmental factors have been applied. It will be calculated as a Service Design Wind Speed, and an
Ultimate Design Wind Speed. These wind speeds should be given to the designer by an authorised
authority, such as an Engineer.
Click Yes when the entries have been made, and the software will move directly to the Snow
calculation section.
For the software to calculate the design and ultimate wind speed, double click the lower button.
Wind Region.
Click the Select button, and a window will display, showing maps of New Zealand and Australian wind
regions.
Click on the map at the job location, and the appropriate wind region for the position will change to RED,
and be selected.
Region
selected
If the job is in an area other than NZ/AUS, click the Not on the map but I know the regional wind
speed button, and you will be taken to the window where the Regional wind speeds can be directly
entered.
Terrain Category
The wind velocity close to the ground is influenced by the terrain it is passing over. Selecting one of the
categories shown below, will apply a factor to the regional wind velocity, that is calculated for that terrain
type.
Clicking the Select button will display the terrain category options.
Click on the picture of the required category to select it. The selected category will display beside the
OK button.
Click OK
Click Next and the wind calc terrain window will open.
Terrain Profile
Clicking the Site on a hill steeper than 1 in 20 button will display the hill profile screen.
Enter the hill profile measurements in the boxes with Red text. The measurements are in meters.
Note. The height of the feature, is measured from a point at its base, where the slope exceeds 3deg
(1 in 20), to a point at its top where the slope is less than 3deg (1 in 20)
For engineering purposes, the terrain between the base point, and the crest, is drawn as a straight line.
If the screen has been filled in error click Cancel, and the software will return to the previous screen.
Click OK and the software will move on to the next wind calc screen.
Site on escarpment steeper than 1 in 20.
Clicking on the Site on escarpment steeper than 1 in 20 button will display the escarpment profile
screen.
Enter the escarpment profile measurements in the boxes with Red text. The measurements are in
meters.
Note. The height of the feature, is measured from a point at its base, where the slope exceeds 3deg
(1 in 20), to a point at its top where the slope is less than 3deg (1 in 20)
For engineering purposes, the terrain between the base point, and the crest, is drawn as a straight line.
The distance X need not exceed (2 x Lu), because this places the building beyond the escarpment
zone.
If the screen has been filled in error click Cancel, and the software will return to the previous screen.
Click OK and the software will move on to the next wind calc screen.
Click on the site location, if the job is in New Zealand. If it is in a lee zone, (red zones), Yes will display.
If located elsewhere click the Regions other than New Zealand. No will display.
Click, OK.
If No is displayed, the 2 lower boxes in the window are not applicable, and should remain blank. If an
entry is accidentally made, it will greyed out and ignored by the software.
If Yes, the distance from the crest of the range in Kilometres, and the site elevation above sea level in
meters, must be entered.
Click Next and the first of the Snow loading calc screens will display.
Snow Loading.
If YES and you have been given the Design Snow Load for the building, click the button.
Note. The DESIGN snow load is the load that will be applied to the structure, after all environmental
factors have been applied. It will be calculated as an Ultimate Design Snow Load. This load should be
given to the designer by an authorised authority, such as an Engineer.
This will open the screen where the Design Snow Load is entered.
After entering the value, click OK, and the first Dead and Imposed (live) load screen will open.
If you have been given the Ground Snow Load for the building, click the button.
Note. The GROUND snow load is the maximum weight of snow expected on the ground at the building
site during a given period of time. This load will have certain factors applied to it to obtain the Design
Snow Load. The ground Snow Load should be given to the designer by an authorised authority, such as
an Engineer.
This will open the screen where the Ground Snow Load is entered.
After entering the value, click OK, and the first Dead and Imposed (live) load screen will open.
If the building site is in Australia or New Zealand, the Snow Load can be calculated from maps showing
Snow regions and altitude information.
Click the button.
Snow Region.
Clicking the Snow region Select button will display maps showing the Aus/NZ snow regions.
Click on the map at the job location, and the snow region will automatically turn RED, and be
selected.
Snow region
Cursor clicked
here
NOTE. Structures situated within the dark brown Alpine regions, where one snowfall has not melted
before the next arrives, require the Ground and Design snow loads for each structure, to be calculated by
a professional engineer. A warning will display when an Alpine region is selected.
Click OK, on the warning box, and the software will move to the Ultimate Ground Snow Load entry
screen.
Note. If the Engineer has supplied the Ultimate DESIGN snow load. Click the Back button to return to
the snow calculation window.
And click the Design Snow Load button, and make the entry.
Site Altitude.
This is the altitude above mean sea level, of the building site.
Use the drop down menu to select the altitude. The menu will only contain altitudes that are appropriate
for the region selected.
This is used to apply the live and dead weight of the ceiling and roof structures.
Where a roof/ceiling is being supplied by others, advice should be sought when filling in the sections, to
ensure that the correct loads are being applied to any supporting walls etc.
Allow For Roof.
Does the structure being engineered have a roof that needs supporting? Internal fit outs, where the roof
is being supported independently will be entered as NO.
Where the structure has, what is considered a ceiling, but no roof, enter YES.
Make the appropriate selection by clicking the Select button, and the selected dead load will display
next to the OK button.
If the roof dead load is known, the value next to the OK button can be overwritten.
Custom Build-ups.
Two custom build-ups can be created, by filling in titles and values in either of the 2 clear examples on
the right and
saved by selecting Save As, Excel Macro_Enabled workbook.
in C:\Program Files
The existing light and heavy build ups on the left, can be modified, and saved as above.
Roof Live Load.
Note. Most roofs are classed as non accessible, because the only reason for access to be gained is for
maintenance or repair of the roof or an appliance on it.
Enter the required load.
Ceiling Dead Load (Self Weight)
Make the appropriate selection by clicking the Select button, and the selected dead load will display
next to the OK button.
If the ceiling dead load is known, the value next to the OK button can be overwritten.
Note. Where significant amounts of electrical equipment, and/or ducting, is placed on the ceiling, it may
be necessary to increase the ceiling dead load accordingly. If in doubt, consult an Engineer.
Custom Build-ups.
Two custom build-ups can be created, by filling in titles and values in either of the 2 clear examples on
the right and
saved by selecting Save As, Excel Macro_Enabled workbook.
in C:\Program Files
The existing light and heavy build ups on the left, can be modified, and saved as above.
.
Ceiling Live Load.
If Yes is selected.
Make the appropriate selection by clicking the Select button, and the selected dead load will display
next to the OK button.
Custom Build-ups.
Two custom build-ups can be created, by filling in titles and values in either of the 2 clear examples on
the right and
saved by selecting Save As, Excel Macro_Enabled workbook.
in C:\Program Files
The existing light and heavy build ups at the top, can be modified, and saved as above.
Floor Live Load
Floor Live Load Override
The floor live load will automatically be entered as per the AS/NZS 1170.1: code, according to the
Function of the proposed building as previously entered.
Make the appropriate selection by clicking the Select button, and the selected dead load will display
next to the OK button.
If the ceiling dead load is known, the value next to the OK button can be overwritten.
Custom Build-ups.
2 Custom build-ups can be created, and saved by selecting Save As, Excel Macro_Enabled
workbook,
in C:\Program Files
The existing direct fix, and suspended ceiling build ups, can be modified, and saved as above
Ceiling Live Load.
The Load Test report PDF will be generated, and default to being saved inside the newly created folder.
The Data entered into the environments, will be summarised, and saved to the SDP file. Subsequent
opening of the job SDP file, will automatically repopulate the Excel file with the saved data.
Excel will then save and close automatically.
Close.
Clicking the Close button, will save and close the Engineering Excel spreadsheet.