Fire Prevention
To protect the lives of guests, employees and the general public who may visit and
use the facilities of a hotel. A basic knowledge regarding fire should assist in
preventing fires and extinguishing them quickly if they occur.
The Fire Triangle
Three components are necessary for a fire to start, if one of the three is not present,
or is removed, then the fire does not happen or it is extinguished. The three parts
are
- Fuel: something to burn.
- Air: oxygen to sustain combustion (to keep the fire going)
- Heat: gas, electricity, etc.
TYPES OF FIRE
circuiting, firstly the power should be cut off and then fire suffocated by cutting off
the supply by covering it with a non conductor like CO2/ dry chemical powder
current flow becomes greater than the preset value the alarm goes.
Heat Detector.
This type is used to detect fire in its more advanced stage when the temp starts to
rise. These work on the principle of:
a) Melting or fusion in metals/plastics.
b) Expansion in solids/liquids/gases.
c) Electrical effect.
Based on the above, there are four types of heat detectors, i.e.
a) Using feasible alloys based on reaching preset temperature value.
b) Using principle of expansion.
c) Linear used for long areas like cable tunnel.
d) Beam combined heat and smoke.
FIRE ALARMS
A fire alarm system is an active fire protection system that controls all the fire
alarm components in a building. Fire alarm systems are subject to stringent
bounding.
The design of fire alarm systems is required to be performed by competent
engineers with experience in fire protection, who are licensed within the
geographical area. A fire alarm system should include, but not limited to, alarm
initiating devices, alarm notification appliances, control units, fire safety control
devices, annunciators, power supplies, and wiring.
A (DACT) digital alarm communicator transmitter should be connected to a pair of
dedicated telephone lines to transmit an alarm signal only to a central station that is
responsible for dispatching the fire department. The connection to the fire
department is usually via a central station monitoring company. If a connection to
the fire department is not already present, the facility will need to determine if
there are two telephone lines available for this connection.
The main fire alarm control unit should automatically transmit alarm signals to a
listed central station using a digital alarm communicator transmitter.
FIRE EXTINGUISHERS
Water Type Fire Extinguishers
Water Soda Acid
This type of fire extinguisher is used for class 'A' fires. It consists of an iron
cylinder that is painted red from outside and contains sodium bicarbonate solution.
On top of it a small bottle of acid, usually sulphuric acid is fixed. Whenever the
cylinder is required to be used, it is inverted and the knob strikes the ground, the
acid bottle breaks on impact and CO2 is produced which comes out with great
force and stops the contact of O2, with the fire and fire is extinguished. This is now
mostly out of use as the chemical ejected can cause damage to the surrounding.
Water (Gas Cartridge)
The water content of this steel cylinder is 9/6 liter and the expelled gas, generally
CO2 is contained in a cartridge fitted inside the body of the FE. The expelled water
is pure water. Removal of a safety pin/plug and pressure on the operating lever sets
the process in motion. With exertion of pressure of gas on the surface of water/ it is
forced out of the nozzle .The discharge can be controlled by the lever.
Water (Stored Pressure)
The function is practically same except that whole container is pressurized or N2 is
pumped in until the pressure reaches specified limit.
when discharged onto it. The discharge horn should be directed at the heart of the
fire, starting at the edge and sweeping across the surface of the burning material.
The discharge range of the C02 FE is fairly limited. After using it indoors, the
room should be ventilated. When using it in open air, the operator should stand
upwind and apply the gas in downwind direction.
Dry Chemical Powder Fire Extinguisher
This can be used for class 'A', 'B', and 'C fires. The most common extinguishing
agents are sodium bicarbonate or baking soda. The extinguisher is charged with
dry chemical and a small tank of C02. The C02 gas exerts pressure on the dry
chemical and forces it out of the nozzle directly to the fire. The powder strikes the
fire and the heat from the fire breaks down the chemical that releases C02 gas
cooling and smothering the fire.
types of fire
Stationary Equipment
It includes Automatic sprinklers, fire hose system and permanently connected
foam, C02 dry chemical powder.
Automatic Sprinklers
They are generally mounted below ceiling height with a temp, detector used with
each sprinkler. The temp. rise in the environment results in activation of a link on
the detector which opens a water valve. The water is then sprayed on the ceiling
and falls to the floor extinguishing the fire. If the volume of fire increases, more
sprinklers get opened up.
Operation
Each sprinkler head is held closed independently by heat-sensitive seals. These
seals prevent water flow until a design temperature is exceeded at the individual
sprinkler heads.
Each sprinkler activates independently when the predetermined heat level is
reached. The design intention is to limit the total number of sprinklers that operate,
thereby providing the maximum water supply available from the water source to
the point of fire origin.
A sprinkler activation will do less damage than a fire department hose, as the fire
department's hose streams provide around 250 US gallons per minute (15 L/s)
whereas an activated sprinkler head generally discharges around 23 US gallons per
minute (1.5 L/s). In addition, the sprinkler will activate immediately; whereas a fire
appliance takes an average of eight minutes to reach an incident.
TYPES
Wet Systems
Typical "wet" systems are simple and passive. They have water already pressurized
in the pipes held back by the sprinkler head. These systems require manual controls
to activate, so long as adequate water supplies are provided.
Dry Systems
Specialty systems called "dry" systems, designed for unheated spaces, have a low
"maintenance" air pressure in the pipes. Water is fed into the system when the
sprinkler "fuses" allowing the maintenance air pressure to reach the minimum
pressure point. "Pre-action" systems are highly specialized for locations where
accidental activation is unacceptable such as museums with rare art works,
manuscripts or books. Pre-action valves are connected to fire alarm initiating
devices such as smoke detectors or heat detectors and virtually eliminate the
possibility of accidental water flow.
Deluge Systems
"Deluge" systems are systems that have open sprinklers, i.e. the fusible link is
removed, so that every sprinkler served by the system will discharge water. This
ensures a large and simultaneous application of water over the entire hazard. These
systems are used for special hazards where rapid fire spread is a concern.
Pre-action Systems
"Pre-action" systems are similar to "deluge" except the sprinklers are closed and
the system is filled with compressed air known as "maintenance air". These
systems are desirable where water discharge through accidental damage to the
system piping and/or sprinklers presents an unacceptable loss risk to valuable
electronic components or other water reactive materials and/or equipment. As the
name implies, these systems require that a "preceding" and supervised event
(typically the activation of a heat or smoke detector) take place prior to the "action"
of water introduction into the system's piping. There are basically three (3) types of
pre-action systems including interlock, non-interlock and double-interlock, all
which offer differing levels of accidental water discharge protection.
Foam and Gas Systems
Other specialty systems may have foam instead of water suppression agents for fire
protection in occupancies with flammable liquids, such as airport hangars. "Clean
agent" gaseous systems, such as Argon/C02/Nitrogen mixtures can be used in very
small spaces where water cannot be used for suppression.
Hose Reels
It is a semi portable system in which the fire hose box is permanently located but
the flexible hose can be moved throughout the building. The hose to fight the fire
should be linen type. The linen hoses allow some water to seepage, which prevents
their burning. The nozzles are connected to large tanks, which contain
extinguishing agent. The tanks are placed outside the room for protection as well as
for recharging during the fire fighting operations.
Employee Training
In the hospitality industry, fire prevention should be the responsibility of every
employee. The first step in fire management is to provide the means to reduce fire
damage through alarms and suppression. The second critical step is employee
training. The causes of most fires in the service industry are
1. Incendiary / Suspicious
2. Electrical distribution
3. Cooking equipment
4. Smoking
5. Appliance, tools, or air conditioning
6. Heating equipment
7. Others
These fire problem areas should be brought to the attention of all employees,
particularly those who are responsible for the operation and servicing of various
building equipment.
Fire training includes fire prevention, operation of fire suppression equipment, and
alarm response. Each of these topics must be discussed with every employee.
Additionally, there is currently considerable interest in the hospitality industry in
the concept of an in-house fire response team. Generally, the fire response team
includes at least two employees from every shift, with the duties of the fire
response team chief being handled by the chief engineer and/or the director of
security.
It is essential that members of the fire response team have hands-on familiarity
with fire-fighting equipment, know all the exit locations in the building, and
understand current evacuation procedures, as well as the operation of the building's
evacuation alarm system. However, it should also be noted that the actions of the
fire response team during an emergency are essentially limited to the time between
the fire alert and the arrival of the local fire department.
Guest Safety
In addition to the fire training and/or education provided employees, the manager
must never overlook the guests, customers, patients, members, and other building
occupants. Fire codes will usually require the posting of exit and evacuation
diagrams and instructions in guest rooms and in public areas of the building.
This information might be supplemented with information about the meaning of
various alarm signals (alert versus evacuation), how guests will instructions in a
fire emergency (by telephone or over a speaker in the guest room), and what to do
if a guest is handicapped and needs special assistance (provide a special telephone
number).
Fire Hazards
A fire hazard is any situation in which there is a greater than normal risk of harm to
people or property due to fire. Fire hazards can take the form of ways that fires can
easily start (as a blocked cooling vent, overload electrical system), ways fires can
spread rapidly (such as insufficiently protected fuel store or areas with high oxygen
concentrations) or things which in fire pose a hazard to people (such as materials
that produce toxic fumes when heated or blocked fire exits).
Fire safety is a component of building safety. It concerns safety measures to
prevent the effects of fires and is the result of proper use of fire protection
measures.
Some elements include:
Having built a facility in accordance with the version of the local building code
that was in effect at the time a building permit was applied for.
Maintaining a facility and conducting oneself in accordance with the provisions
of the fire code, from the moment that the building was occupied.
Examples of such lawful conduct include, but are not limited to, the following:
Not exceeding the maximum occupancy listing for any part of the building
(making sure that an area isn't so full of people that they can't all get out quickly in
an emergency).
Maintaining proper fire exits and proper signage of them (e.g., exit signs pointing
to them that can function in a power failure).
Placing and maintaining fire extinguishers and fire alarms in easily accessible
places.