Sunteți pe pagina 1din 80

CLICK PLCs

Section 1

Section 2

DL105 PLC
Section 3

DL205 PLC
Section 4

DL305 PLC
Section 5

DL405 PLC
Section 6

Click on part #s
to link directly to
our online store for
current pricing, specs,
stocking information
and more

,i
nly

red
rde
fo

w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c

Use bookmarks to
save, search, print
or e-mail the catalog
section

.S o
the U

Section 7

Use bookmarks to
navigate by product
category

in
Available

Productivity3000

Programmable Controllers

DL05/06 PLC

In this interactive PDF


you can:

by
6p
m

ET.,
add
ition
al sh

ly.
ipping charges may app

Volume 14

e1-1

Just CLICK! For Simple discrete and analog control


Shown actual size

Removable
terminal block

Eight built-in
discrete inputs

Six built-in
discrete outputs

Two communication ports


support operator interfaces,
PC programmers or any
Modbus RTU device

Just add 24 VDC


to get running.
Or, add a CLICK
110 VAC to 24VDC
power supply

Mighty as a stand-alone unit, or expand to 142 total I/O!

Just CLICK
to get started

The CLICK family is an easy-touse controller that is cost-effective


even in applications that would
require just a few relays, and more
flexible to boot.
With a starting price of $69.00 for
a discrete controller offering eight
built-in digital inputs and six built-in
digital outputs, this stand alone
micro brick PLC is by far the most
practical choice for the money.

LOW
PRICES

Just CLICK

Just CLICK

The CLICK PLC programming


software is available as a FREE
download from our Web site.

Koyo Electronics, our parent


company, is part of the multibillion
dollar JTEKT group of companies
that primarily provides components
to automotive manufacturers such
as Toyota.

to get FREE Software

Unlike many FREE programming


packages you may be familiar with,
this software is packed with features
that simplify your learning curve
and shorten your programming
time.

FREE
SOFTWARE

for quality

With their extensive engineering


and manufacturing background,
we expected nothing but the best,
and Koyo delivered! While
development focused on building a
reliable product, they were also
able to deliver a product that offers
the best combination of price, ease
of use, and features.
The price is almost free while the
quality and ease of use is almost
priceless.

QUALITY
CONSTRUCTION

Volume 14

e1-2

Programmable Controllers

1 - 80 0 - 633 - 0405

What is it?

Simply CLICK to get started

CLICK micro-brick PLCs, starting at


$69.00, offer stackable I/O modules
and free programming software for a
low-cost and easy-to-use high-quality
machine controller. It is designed for
first-time PLC customers as well as
experienced users.

Whats it got?

Eleven stand-alone DIN-rail mount


DC-powered CPU combinations,
including:
- 8 DC In / 6 DC Out (sinking)
- 8 DC In / 6 DC Out (sourcing)
- 8 DC In / 6 Relay Out
- 8 AC In / 6 Relay Out
- 4 DC In / 4 DC Out (sinking),
2 analog in, 2 analog out
(current / voltage selectable)
- 4 DC In / 4 DC Out (sourcing),
2 analog in, 2 analog out
(current / voltage selectable)
- 4 DC In / 4 Relay Out,
2 analog in, 2 analog out
(current / voltage selectable)

Built-in communication ports


(two in basic CPUs, three in
standard and analog CPUs)
Real-time clock and battery back-up
in standard and analog CPUs
Removable terminal blocks
24 stackable, I/O option modules
Program AND documentation stored
in CPU
FREE, high-feature programming software

What can it do?

Replace even just a few relays costeffectively and gain a world of flexibility. Interface to any Modbus RTU
enabled device with the RS-232
communication ports (6P6C/RJ12
connectors) and/or RS-485 port
(on standard and analog CPUs).
POWER SUPPLIES

C0-01AC

$39.00
Auxilary Power Supply (1.3A)
100-240VAC Input
24VDC 1.3A Output

Company
Information
Systems
Overview

What does it take


to get started?

 1:
 2:
 3:

Programmable
Controllers
Field I/O

Click on our Web site at www.clickplcs.com to view


all the latest detailed product information.

Software

Click http://support.automationdirect.com/demos.html
to download free software and take a test drive.

C-more &
other HMI

Click on our store www.automationdirect.com and


get a CLICK shipped the same day!

Drives
Soft
Starters
Motors &
Gearbox
Steppers/
Servos
Motor
Controls
Proximity
Sensors
Photo
Sensors

BASIC PLC UNITS

Two RS-232 comm ports


Super Capacitor

$69.00
C0-00DD1-D

8 DC sink/source inputs,
6 DC sinking outputs

$69.00
C0-00DD2-D

8 DC sink/source inputs,
6 DC sourcing outputs

Limit
Switches

STANDARD PLC UNITS

Encoders

Two RS-232 comm ports


One RS-485 comm port
Super Capacitor plus battery
Real-time clock

Current
Sensors
Pressure
Sensors

$99.00
C0-01DD1-D

ANALOG PLC UNITS

8 DC sink/source inputs,
6 DC sinking outputs

$99.00
C0-01DD2-D

8 DC sink/source inputs,
6 DC sourcing outputs

Two RS-232 comm ports


One RS-485 comm port
Super Capacitor plus battery
Real-time clock

$129.00
C0-02DD1-D

4 DC inputs, 4 DC sinking outputs,


2 Analog inputs, 2 Analog outputs

$79.00
C0-00DR-D

$109.00
C0-01DR-D

8 DC sink/source inputs,
6 Relay outputs

$129.00
C0-02DD2-D

4 DC inputs, 4 DC sourcing outputs,


2 Analog inputs, 2 Analog outputs

C0-00AC

Auxilary Power Supply (0.5A)


100-240VAC Input
24VDC 0.5A Output

Pushbuttons/
Lights
Process
Relays/
Timers
Comm.
Terminal
Blocks &
Wiring
Power

8 DC sink/source inputs,
6 Relay outputs

$29.00

Temperature
Sensors

$79.00
C0-00AR-D

8 AC inputs, 6 relay outputs

C0-01AR-D

$109.00
8 AC inputs, 6 relay outputs

$139.00
C0-02DR-D

4 DC inputs, 4 Relay outputs,


2 Analog inputs, 2 Analog outputs
Volume 14

w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c

Programmable Controllers

e1-3

Circuit
Protection
Enclosures
Tools
Pneumatics
Safety
Appendix
Product
Index
Part #
Index

Just CLICK to make a larger PLC


Add up to eight different I/O
modules to build a 142-I/O
PLC system

DISCRETE OUTPUT MODULES

$35.00
C0-08TD1

8 DC Outputs
(Sinking)
3.3-27 VDC
0.3A/pt

Expandable to 142 I/O

Optional 110 VAC to 24 VDC


power supply

At $69.00, you get a ton of application control


for your automation buck. The CLICK PLC
offers you many options for your discrete and
simple analog control applications.

The basic and standard CPUs offer, built in, eight


digital inputs and six digital outputs; the analog
CPUs include four digital inputs, four digital
outputs, two analog inputs and two analog
outputs. These DC-powered PLCs are a mighty
controller as a stand alone unit, or expand your
I/O with up to eight of the 24 available option
modules for up to 142 total I/O. The I/O lineup
offers you 24 VAC input, both sinking and
sourcing 24 VDC input and output options, 120
VAC input and output modules, and relay
modules up to seven amps for your discrete
applications; analog modules support 4-20 mA
or 0-10 VDC input and output options for simple
process measurement and control.

With multiple options for main input power, you


decide what best fits into your control panel. Use
your existing 24 VDC power supply (if applicable),
select one of our low-cost CLICK PLC power
supplies (based on your system power budget
requirements) or select one of AutomationDirects
rugged Rhino power supplies.

Two RS-232 communications ports supporting


industry standard Modbus RTU protocol are included
on all units. These ports are suitable for connection to
a PC for programming, networking PLCs, Cmore/C-more Micro operator interface panels, variable frequency drives, servos, steppers, and other
Modbus RTU enabled devices. The standard and
analog CPUs also include one RS-485 port.

Need inexpensive data logging? DataLynx (see


Software section) can collect data from remote
locations or relay data from multiple locations
back to a single location to be stored. Interface to
CLICK via Modbus protocol over a serial or
modem connection.

8 DC Outputs
(Sourcing)
12-24 VDC
0.3A/pt

$45.00
C0-16TD1

16 DC Outputs
(Sinking)
5-27 VDC
0.1A/pt

Simple to learn ... easy to use $45.00


The CLICK PLC programming software is based

on the C-more and C-more Micro programming


environments. We leveraged these two great
programming packages developed by Koyo to
created CLICKs intuitive programming tool, and
then made it a FREE download from our Web
site. So you now have free software for your practically free PLC! But dont let the $0 price tag fool
you - youll find this software loaded with options
that you would normally expect to pay extra for!

C0-16TD2

16 DC Outputs
(Sourcing)
12-24 VDC
0.1A/pt

$50.00
C0-08TA

8 AC Outputs
17-240 VAC triac
0.3A/pt

DISCRETE INPUT MODULES

$33.00

$35.00
C0-08TD2

C0-08ND3

C0-08ND3-1

$33.00

C0-16ND3

$45.00

C0-08NA

$40.00

$40.00

8 DC Inputs
(Sink/Source)
12-24 VDC

8 DC Inputs
(Sink/Source)
3.3-5 VDC

16 DC Inputs
(Sink/Source)
24 VDC

8 AC Inputs
100-120 VAC

8 Relay Outputs
6-240 VAC or
6-27 VDC
1A/pt

C0-08NE3

C0-16NE3

$45.00

$44.00

8 AC/DC Inputs
(Sink/Source)
24 VAC/VDC

16 AC/DC Inputs
(Sink/Source)
24 VAC/VDC

4 Relay Outputs
6-240 VAC or
6-27 VDC
7A/pt

$33.00

C0-08TR

C0-04TRS

Volume 14

e1-4

Programmable Controllers

1 - 80 0 - 633 - 0405

Now CLICK to add Analog I/O


Add up to eight Analog I/O
modules and interface with
over 50 analog channels!

Prices start at $22.25 per


channel (4-chanel module).
Thermocouple (or RTD) channels
are $37.25 each.
Can your current PLC match that?

Measure Temperature
(with RTDs or Thermocouples)...

...Measure Current Usage


(with Current Transducers)...

... detect tank levels


(with Level Sensors)...

...Provide Speed or Torque


Control for AC Drives...

Add analog
I/O modules

If the CLICK Analog CPUs dont


provide enough analog channels, now you can add analog
channels with our 4-channel
input and/or 4-channel output
modules, OR check out the
combo modules with 4-channels IN and 2 channels OUT.
Each style is available in either
current or voltage flavors.
Connect to all your analog
devices: pressure and level
transmitters, current transducers,
proportional valves, AC drives,
panel meters, etc.

These high-resolution modules


offer fast setup (no DIP switches)
with software scaling to make
your life (and your ladder code)
easier.

...Connect to any Analog Device


that You Need to Control!

Systems
Overview

ANALOG INPUT MODULES

Programmable
Controllers

$89.00

$89.00

4 Channel
Current Inputs
0-20mA
13 Bit Resolution

4 Channel
Voltage Inputs
0-10VDC
13 Bit Resolution

C0-04RTD

C0-04THM

C0-04AD-1

C0-04AD-2

$149.00

$149.00

4 Channel
RTD Inputs
(0.1 degree) or
Resistive Inputs

4 Channel
Thermocouple
Inputs
(0.1 degree) or
Voltage Inputs

C0-04DA-1

C0-04DA-2

4 Channel
Current Outputs
4-20mA Source
12 Bit Resolution

4 Channel
Voltage Outputs
0-10 VDC
12 Bit Resolution

ANALOG COMBO MODULES


C0-4AD2DA-2

$149.00

4 CH Voltage Inputs
0-10 VDC (13 bit)
2 CH Voltage Outputs
0-10 VDC (12 bit)

$59.00
8 Inputs (24V)
(Sink/Source)
PLUS 8 Outputs
5-27VDC (Sink)

$59.00
C0-16CDD2

8 Inputs (24V)
(Sink/Source)
PLUS 8 Outputs
12-24VDC (Source)

$49.00
C0-08CDR

Motors &
Gearbox

Photo
Sensors
Limit
Switches
Encoders
Current
Sensors

Temperature
Sensors
Pushbuttons/
Lights
Process
Relays/
Timers

Terminal
Blocks &
Wiring

Double up and save...

Need a few extra Inputs and outputs? Use


these combo modules to expand your
CLICK system AND save money.

4 Inputs (12-24VDC)
(Sink/Source)
PLUS 4 Relay Outputs
1.0A AC/DC
Volume 14

w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c

Soft
Starters

Comm.

Double CLICK to add Discrete COMBO Modules


C0-16CDD1

Drives

Pressure
Sensors

Using the programming software, set your preferred


scaling range, and and assign a data register address to
store the scaled analog value. The real world resolution
is calculated automatically.

DISCRETE COMBO MODULES

C-more &
other HMI

Proximity
Sensors

$119.00

$149.00

Software

Motor
Controls

$119.00

C0-4AD2DA-1

Field I/O

Steppers/
Servos

ANALOG OUTPUT MODULES

4 CH Current Inputs
0-20mA (13 bit)
2 CH Current Outputs
4-20mA (12 bit)

Setup couldnt be any easier

Company
Information

Programmable Controllers

e1-5

Power
Circuit
Protection
Enclosures
Tools
Pneumatics
Safety
Appendix
Product
Index
Part #
Index

CLICK to get FREE Programming Software!

Simple to learn ...

The CLICK PLC programming tool was


designed with the user in mind. We have
simplified the programming process to
make it easier to learn, faster to program,
and capable of completing most of your
discrete application needs with only 21
instructions!

This combination of RLL (Relay Ladder


Logic) and Function block programming
offers you a comprehensive programming
environment with easy navigation and a
familiar Windows look and feel.

Simply download your free


software at:

... Easy to use

We listened to our customers and tried to


address what they felt were the inhibitors
to a simplistic programming environment.
This includes more intuitive instructions
that are not only easier to use but also
offer more functionality at the same time.
We worked to create one of the best help
files of any software in the industry. We
offer you enough options to easily address
the majority of your needs during all
phases of programming (learning, coding,
commissioning, troubleshooting), while
keeping it structured enough to make the
basic operations obvious.

Action-packed

The CLICK PLC Programming tool allows


each individual to set up their programming environment to suit their needs.
Beginners may choose to program
almost exclusively via the mouse by
clicking on icons, instructions, drop-down
menus, and selecting PLC addresses from
the Address Picker. As programmers
become
more
experienced,
the
time-saving keyboard shortcuts can
greatly enhance productivity, and speed
development/debug times. Many of the
instruction entry shortcuts are even the
same as those used in our DirectLOGIC
PLC software.

Either way, you can select the option that


suits your style of programming.

www.clickplcs.com

Volume 14

e1-6

Programmable Controllers

1 - 80 0 - 633 - 0405

Simplified instruction set reduces


your programming time

Company
Information
Systems
Overview
Programmable
Controllers
Field I/O

Instruction List

Software

The CLICK PLC programming software offers 21 extremely powerful


instructions! This instruction set offers the same flexible control you
might expect from over 150 instructions in a traditional controller.
Simply drag and drop these instructions onto the ladder view (the center section of the screen), and a helpful dialog box will guide you
through each instructions configuration.

C-more &
other HMI
Drives
Soft
Starters
Motors &
Gearbox
Steppers/
Servos
Motor
Controls
Proximity
Sensors
Photo
Sensors
Limit
Switches
Encoders
Current
Sensors
Pressure
Sensors
Temperature
Sensors
Pushbuttons/
Lights
Process
Relays/
Timers

Whats included?

Comm.
Terminal
Blocks &
Wiring

The 21 CLICK PLC instructions include everything you would typically expect:

Contacts*
Coils
Compare
Set/Reset

Timer
Counter
Math**
For/Next

Then there are some advanced instuctions you might not expect:
DRUM
Send/Receive
Copy

Shift Register
Call/Return(Subroutine)
Search

Power

Note: The RETURN instruction is not


included in this list because it is used
in the Subroutine and Interrupt
programs only.

Enclosures
Tools
Pneumatics
Safety
Appendix

* Contacts include Normally Open, Normally Closed, Edge-triggered and Compare


** Math includes Decimal, Floating Point and HEX math. Supports free-form formula entry.

Product
Index

Volume 14

w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c

Circuit
Protection

Programmable Controllers

e1-7

Part #
Index

CLICK offers intuitive navigation


Navigation Pane

The CLICK PLC programming software offers an


easy-to-view Navigation Pane which places program
controls at your fingertips. Quickly toggle between
your main program, Subroutines, Interrupts, Data
Views, Rung Comments Editor and more.

At your fingertips

The Navigation Pane puts many practical and frequently used functions
within one CLICK of your mouse during configuration, commissioning and
troubleshooting. Quickly move between your Main Ladder Program and
Subroutines and Interrupt routines within your project. Access frequently
used system functions such as System Setup, Password utility, Comm Port
Configuration, PLC Connection, Data and Project Transfer, Firmware
Update and many more. Many of these functions are also available via
drop-down menus. Its your choice!
Use the color-coded Window Control Toolbar to quickly and easily hide
the navigation (and/or instruction) pane to maximize your ladder
programming work space.

Volume 14

e1-8

Programmable Controllers

1 - 80 0 - 633 - 0405

Monitor your program with a CLICK

Company
Information
Systems
Overview

Data View Window

Programmable
Controllers

The Data View allows you to monitor real time


values in your process directly from the PLC while
monitoring the system with the programming
software. You can view up-to-date data, write
new variable data, and even force overrides in
the processor from this one window.

Field I/O
Software
C-more &
other HMI
Drives
Soft
Starters
Motors &
Gearbox
Steppers/
Servos
Motor
Controls
Proximity
Sensors
Photo
Sensors
Limit
Switches
Encoders
Current
Sensors
Pressure
Sensors
Temperature
Sensors
Pushbuttons/
Lights
Process
Relays/
Timers
Comm.
Terminal
Blocks &
Wiring

What is included?

Power
Circuit
Protection

The Data View allows you to monitor data as you would expect ...
but what else can you do?
Auto Fill Down feature allows you to quickly populate
your addresses
View data types as either Integer, Real (floating point),
Exponential or Hex.
Force values with the Override feature.
Import/Export your data View to exchnage the setup.
Save and create multiple Data View files for separate
process applications.
Data types are easily identifed by the Data Type icons
on the Status Bar.

Enclosures
Tools
Pneumatics
Safety
Appendix
Product
Index

Volume 14

w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c

Programmable Controllers

e1-9

Part #
Index

Monitor your program


with a CLICK
Data View Window

The Data View allows you to monitor real time


values in your process directly from the PLC while
monitoring the system with the programming
software. You can view up-to-date data, write
new variable data, and even force overrides in
the processor from this one window.

What is included?

The Data View allows you to monitor data as you would expect .
but what else can you do?
Auto Fill Down feature allows you to quickly populate
your addresses
View data types as either Integer, Real (floating point),
Exponential or Hex.
Force values with the Override feature.
Import/Export your data View to exchnage the setup.
Save and create multiple Data View files for separate
process applications.
Data types are easily identifed by the Data Type icons
on the Status Bar.

Check I/O status with a CLICK


Displays the current LED
indicator status for all I/O
points

Select the display type


for each analog module
separately.

View the Physical Values


or the Scaled Values for
all analog channels

Volume 14

e1-10

Programmable Controllers

1 - 80 0 - 633 - 0405

CLICK on a practical instruction

Company
Information

For example ...

Systems
Overview

Timer Instruction

Programmable
Controllers

The Timer Instructions are typically some of the more basic


instructions in a control environment, so how could we possibly
make them any better? We listened to you ...

Field I/O
Software
C-more &
other HMI

Instead of having multiple timer instructions with different


functions and features, we created a single timer instruction
with simple selections to allow programming of the precise
timer function needed for your application. Select from Ondelay or Off-delay timing and retentive or non-retentive current
values.

Drives
Soft
Starters
Motors &
Gearbox

Just CLICK ... Its that easy.

Steppers/
Servos
Motor
Controls

...

Proximity
Sensors
Photo
Sensors
Limit
Switches
Encoders
Current
Sensors
Pressure
Sensors
Temperature
Sensors
Pushbuttons/
Lights
Process
Relays/
Timers
Comm.
Terminal
Blocks &
Wiring

Math Instruction

Power

Performing mathmatical calculations in a PLC


typically requires a complicated set of
instructions and programming gymnastics. From
mixing
process
variable
data
with
constants in multiple formats, to calculating complex logarithmic formulas, math
computations in ladder logic can be complex, so how could we possibly make it any
better? We listened to you...

Circuit
Protection
Enclosures
Tools
Pneumatics

Instead of having a full set of various math instructions you string together to
perform complex mathmatical equations, we created a single instruction that allows
you to enter formulas directly or select from the familiar calculator
style layout to create your formula.

Safety
Appendix
Product
Index

Just CLICK ... Its that easy.

Volume 14

w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c

Programmable Controllers

e1-11

Part #
Index

CLICK for great help!


Detailed Help Files

We wanted your programming experience to be the easiest and most productive of any PLC you have ever programmed. So we spent a lot of time creating
the content for the help file that gives you clear and concise definitions of the
features and functionality for each instruction and the operation of the software.
Just CLICK Help ... Its that easy.

Volume 14

e1-12

Programmable Controllers

1 - 80 0 - 633 - 0405

CLICK to configure the hardware

Company
Information
Systems
Overview

System Configuration

Programmable
Controllers

The CLICK software includes a configuration tool that helps you configure a CLICK PLC
quickly and easily. Select the CPU, power supply, and modules you need - the software
calculates your I/O count, address list, and Power Budget automatically.

Field I/O
Software
C-more &
other HMI
Drives
Soft
Starters
Motors &
Gearbox
Steppers/
Servos
Motor
Controls
Proximity
Sensors
Photo
Sensors
Limit
Switches

CLICK to configure the PLC tags

Encoders
Current
Sensors
Pressure
Sensors

Address Picker

Temperature
Sensors

Assign nicknames

(use autofill for sequential names)

Create address comments

Powerful search, sort, filter, and

categorize options

Modbus addresses

Pushbuttons/
Lights
Process
Relays/
Timers
Comm.
Terminal
Blocks &
Wiring
Power

(HEX or 984 style)

Establish initial values for

Circuit
Protection

specific memory locations

Enclosures

(during power outages)

Pneumatics

Make memory locations retentive

Tools

Safety
Appendix
Product
Index

Volume 14

w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c

Programmable Controllers

e1-13

Part #
Index

CLICK has practical accessories


The ZIPLink wiring system eliminates the normally tedious process
of wiring PLC I/O to terminal blocks. Simply plug one end of a
ZIPLink pre-wired terminal block cable into your I/O module and
the other end into a ZIPLink connector module. Its that easy.
ZIPLinks use half the space, at a fraction of the total cost of
terminal blocks.
Three ZIPLink cable lengths are available: 0.5m (1.6ft.), 1.0m
(3.3ft.), and 2.0m (6.6ft.). See Wiring Solutions section of
catalog.
Other accessories include a hardware manual, programming
cables, spare terminal blocks, and replacement batteries for
analog CPU modules

I/O Module

ZIPLink Sensor Input Module

ZIPLink Cable

ZIPLink Fuse Module

ZIPLink Connector Module

Programming Cables

EA-MG-PGM-CBL
$39

Hardware User Manual

Spare Terminal Blocks

D2-DSCBL
$10

Replacement Battery

Volume 14

e1-14

Programmable Controllers

1 - 80 0 - 633 - 0405

CLICK PLC Overview

Company
Information

PLC System

The CLICK PLC family of components is designed


to offer practical PLC features in a compact and
expandable design and, at the same time, offer
the best ease-of-use.
System Configuration

A powered CLICK CPU module by itself can be


used as a complete PLC system with 8 input points
and 6 output points built-in (Basic and Standard
CPUs) or with 4 output points, 2 analog input
points and 2 analog output points (Analog CPUs).
The system can also be expanded with the addition of up to 8 I/O modules. A variety of discrete
and analog I/O modules are available for flexible
and optimal system configuration.
Decimal Memory Addressing

The I/O numbering system and memory


addressing are decimal to make it easier to count
the number of I/O points and data registers.
Communications

Systems
Overview
Programmable
Controllers

Use a CLICK PLC as a stand-alone controller...

Field I/O
Software
C-more &
other HMI
Drives
Soft
Starters

or, expand the system by installing up to eight additional I/O modules.

Proximity
Sensors
Photo
Sensors
Limit
Switches
Encoders
Current
Sensors

Analog I/O

Locking Tabs

Pressure
Sensors
Temperature
Sensors

Modules easily connect to each other

Pushbuttons/
Lights

Calendar / Clock & Battery Backup

Standard and Analog CPU modules include the


real time clock and battery backup for the internal
SRAM. Battery allows data to be stored for 5 years
(Battery sold separately).

Process
Relays/
Timers

FREE Programming Software

The CLICK programming software can be downloaded free from our Web site and provides an
intuitive programming tool that will get you up and
running quickly.

Steppers/
Servos
Motor
Controls

All CPUs have two built-in RS-232 communications ports. Standard and Analog CPUs also have
one built-in RS-485 communications port. One
RS-232 port supports the Modbus RTU protocol
only and can be used as the programming port.
The other ports support either Modbus RTU or
ASCII protocol. Both RS-232 ports supply 5 VDC,
so you can connect a monochrome C-more Micro
HMI panel without an additional power supply.
Analog CPU modules have built-in analog I/O (2channel analog inputs and 2-channel analog
outputs). Analog input, output and combo I/O
modules are also available.

Motors &
Gearbox

Comm.

Terminal
Blocks &
Wiring

FREE programming software!

Power

Easy-to-Use Instructions

Circuit
Protection

The CLICK PLC supports a very simple but practical instruction set. The easy-to-use instructions
can cover most applications that are suitable for
this class of PLC (the CLICK PLC does not support
DirectLOGIC instructions).

Enclosures
Tools
Pneumatics

8,000 Steps Program Memory

Appendix

The CLICK CPU module can store up to 8,000


steps of ladder program in its flash EEPROM
memory.
2 Year Warranty

Product
Index
Part #
Index

All CLICK PLC modules are covered under a 2


year warranty.

w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c

Volume 13

Programmable Controllers

e1-15

CLICK PLC Overview


CPU Modules

The eleven CLICK CPU modules are available with


different combinations of built-in I/O types.

CLICK Basic CPU Modules


Part Number
C0-00DD1-D
C0-00DD2-D
C0-00DR-D
C0-00AR-D

Basic CPU

Inputs
(8 points)

Outputs
(6 points)

Price

DC (0.1 A, 5-24 VDC, Sink)

<--->

DC (24 VDC, sink/source)

DC (0.1 A, 24 VDC, Source)

<--->

Relay (1 A@6-27 VDC/6-240 VAC)

AC (100-120 VAC)

<--->
<--->

Basic CPU Module Features:


Eight discrete input points
Six discrete output points
Two RS-232 communications ports

CLICK Standard CPU Modules


Part Number
C0-01DD1-D
C0-01DD2-D
C0-01DR-D
C0-01AR-D
Standard CPU

Inputs
(8 points)

DC (24 VDC, sink/source)

AC (100-120 VAC)

Outputs
(6 points)

Price

DC (0.1 A, 5-24 VDC, Sink)

<--->

DC (0.1 A, 24 VDC, Source)

<--->

Relay (1 A@6-27 VDC/6-240 VAC)

<--->
<--->

Standard CPU Module Features:


Eight discrete input points
Six discrete output points
Two RS-232 communications ports
One RS-485 communications port
Calendar / clock
Battery backup (Battery sold separately)

CLICK Analog CPU Modules


Part Number
C0-02DD1-D
C0-02DD2-D
C0-02DR-D

Analog CPU

Inputs
(4 points)

Outputs
(4 points)

Analog Inputs, Outputs

2 channels in / 2 channels out;


voltage (0-5 VDC) and
current (4-20 mA)
DC (0.1 A, 24 VDC, Source)
selectable, 12-bit resolution for
Relay (1 A@6-27 VDC/6-240 VAC) both inputs and outputs
DC (0.1 A, 5-24 VDC, Sink)

DC (24 VDC,
sink/source)

Price
<--->
<--->
<--->

Analog CPU Module Features:


Four discrete input points and four discrete output points
Two analog input points and two analog output points (not isolated)
Two RS-232 communications ports
One RS-485 communications port
Calendar / clock
Battery backup (Battery sold separately)

Volume 13

e1-16

Programmable Controllers

1 - 80 0 - 633 - 0405

CLICK PLC Overview


Power Supplies

Company
Information
Systems
Overview

DC-DC Converter

Two power supplies are offered.

This DC-to-DC converter can be


used to power the CLICK PLC
from 12 VDC input power.

CLICK Power Supplies


Part Number
C0-00AC
C0-01AC

Output
Current

Price

85-264 VAC

0.5A @ 24 VDC

<--->

Field I/O

85-264 VAC

1.3A @ 24 VDC

<--->

Software
C-more &
other HMI

12 VDC-to-24 VDC Converter

Discrete Input Modules


C0-00AC

C0-08ND3

Part Number

Input
Voltage

Output
Current

Price

PSP24-DC12-1

9.5-18 VDC

1.0A @ 24 VDC

<--->

C0-01AC

C0-08ND3-1

Soft
Starters

Steppers/
Servos

CLICK Discrete Input Modules

C0-16ND3

Drives

Motors &
Gearbox

PSP24-DC12-1

There are six discrete input modules available.

Programmable
Controllers

Input
Voltage

Part Number
C0-08ND3
C0-08ND3-1
C0-16ND3
C0-08NE3
C0-16NE3
C0-08NA

Inputs

Price

DC (8 pts, 12-27 VDC)

<--->

DC (8 pts, 3.3-5 VDC)

<--->

DC (16 pts, 24 VDC)

<--->

AC/DC (8 pts, 24 VAC/VDC)

<--->

AC/DC (16 pts, 24 VAC/VDC)

<--->

AC (8 pts, 100-120 VAC)

<--->

Motor
Controls
Proximity
Sensors
Photo
Sensors
Limit
Switches
Encoders
Current
Sensors
Pressure
Sensors
Temperature
Sensors

Discrete Output Modules


C0-08NE3

Pushbuttons/
Lights

C0-08NA

C0-16NE3

Process

There are seven discrete output modules available.

C0-08TD1

C0-08TD2

Relays/
Timers

CLICK Discrete Output Modules

C0-16TD1

Part Number
Outputs
DC (8 pts, 0.3 A @ 3.3-27 VDC, Sink)
C0-08TD1
DC (8 pts, 0.3 A @ 12-24 VDC, Source)
C0-08TD2
DC (16 pts, 0.1 A @ 5-27 VDC, Sink)
C0-16TD1
DC (16 pts, 0.1 A @ 12-24 VDC, Source)
C0-16TD2
AC (8 pts, 0.3A @ 17-240 VAC)
C0-08TA
Relay
(4 pts, 7A @ 6-27 VDC/6-240 VAC)
C0-04TRS*
Relay (8 pts, 1A @ 6-27 VDC/6-240 VAC)
C0-08TR

Price
<--->
<--->
<--->
<--->
<--->
<--->
<--->

* To drive more than a 7A load or to use replaceable relays, consider


using a C0-16TD1 output module with a ZL-RRL16-24-1 ZIPLink
relay module and the correct ZIPLink cable (see Wiring System for
CLICK PLCs later in this section).

Comm.
Terminal
Blocks &
Wiring
Power
Circuit
Protection
Enclosures
Tools
Pneumatics
Appendix
Product
Index
Part #
Index

C0-16TD2

C0-08TA

C0-04TRS

C0-08TR
Volume 13

w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c

Programmable Controllers

e1-17

CLICK PLC Overview


Discrete Combo I/O Modules

There are three discrete combo modules available.

Discrete Combo I/O Modules


Part
Number

Input Type

Output Type

Price

DC (8 pts, 24 VDC)

DC (8 pts, 0.1A @ 5-27 VDC, Sink)

<--->

DC (8 pts, 24 VDC)

DC (8 pts, 0.1A @ 12-24 VDC, Source)

<--->

DC (4 pts, 12-24 VDC)

Relay (4 pts, 1A @ 6.25-24 VDC /


6-240 VAC

<--->

C0-16CDD1
C0-16CDD2
C0-08CDR
C0-16CDD1

C0-16CDD2

Analog Input Modules

C0-08CDR

There are four analog input modules available.

Analog Input Modules


Part
Number
C0-04AD-1
C0-04AD-2
C0-04RTD
C0-04AD-1

C0-04AD-2

C0-04RTD

C0-04THM

C0-04THM

Analog Output Modules

Analog Input Types

Price

4 channel, current (0-20 mA), 13 bit

<--->

4 channel, voltage (0-10 V), 13 bit


4 channel RTD input (0.1 degree C/F
resolution), or resistive input (0 - 3125,
0.1 or 0.01 resolution)
4 channel thermocouple input (0.1 degree
C/F resolution), or voltage input
(-156.25 mV to 1.25 V, 16 bit)

<--->
<--->
<--->

There are two analog output modules available.

Analog Output Modules


Part Number
C0-04DA-1
C0-04DA-2

C0-04DA-1

Analog Output Types

Price

4 channel, current sourcing (4-20 mA), 12 bit

<--->

4 channel, voltage (0-10 V), 12 bit

<--->

C0-04DA-2

Analog Combo I/O Modules

There are two analog combo modules available.

Analog Combo I/O Modules


Part Number
C0-4AD2DA-1
C0-4AD2DA-2

C0-4AD2DA-1

Analog Input Type

Analog Output Type

4 channel, current
(0-20 mA), 13 bit
4 channel, voltage
(0-10 V), 13 bit

2 channel, current sourcing


(4-20 mA), 12 bit
2 channel, voltage
(0-10 V), 12 bit

Price
<--->
<--->

C0-4AD2DA-2

Volume 13

e1-18

Programmable Controllers

1 - 80 0 - 633 - 0405

CLICK PLC Overview

Company
Information
Systems
Overview
Programmable
Controllers

What youll need

Of course, what youll need for your system


depends on your particular application, but
this overview shows you what youll need
for a simple system.

2.

Field I/O

1.

Software

Select your CLICK CPU module.

C-more &
other HMI
Drives
Soft
Starters

If you need additional I/O, select from


thirteen types of I/O modules.

Motors &
Gearbox
Steppers/
Servos
Motor
Controls

3.

Proximity
Sensors

Select a 24 VDC power supply.

Photo
Sensors

or

Limit
Switches

4.

Encoders

Download the FREE CLICK


programming software.

Current
Sensors
Pressure
Sensors
Temperature
Sensors

5.

Select your PC-to-PLC programming cable.

Pushbuttons/
Lights

EA-MG-PGM-CBL

If your PC has a USB port, use cable EA-MG-PGM-CBL to connect


to the CPU module port. If your PC has a 9-pin serial communications port, use programming cable D2-DSCBL.

Process
Relays/
Timers
Comm.

or

Terminal
Blocks &
Wiring

D2-DSCBL

6.

Power

Select tools, wire, and provide power.


Screwdriver
DN-SS1

Wire Strippers
DN-WS

Circuit
Protection

Hookup Wire

(PC requires RS-232 port


to use this cable)

Enclosures
Tools
Pneumatics
Appendix
Product
Index
Part #
Index

Volume 13

w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c

Programmable Controllers

e1-19

CLICK Programming Software


FREE Software!

CLICK programming software can be


downloaded at no charge.

The CLICK programming software is


designed to be a user-friendly application,
and the tools, layout, and software interaction provide ease-of-use and quick
learning.

The simple operation of this software


allows users to quickly develop a ladder
logic program. The online help file
provides information that will help you get
acquainted with the software quickly.

NOTE: CLICK PLCs cannot be programmed using Direct SOFT


programming software, which is used to program our Direct LOGIC PLCs;
you must use the CLICK programming software.

Main window

The Main Window is displayed when the program opens. It is divided into
Menus, Toolbars, and Windows that work together to make project development as simple as possible.

PC Requirements

CLICK PLC Windows-based programming


software works with Windows 2000
Service Pack 4, XP Home or Professional,
Vista (32 bit), and Windows 7 and
Windows 8 (32 bit and 64 bit for both).
These are the minimum system requirements:
Personal Computer with a 333 MHz (2000
SP4/XP), 800 MHz (Vista), 1 GHz (Windows
7 and Windows 8) or higher processor
(CPU) clock speed recommended; Intel
Pentium/Celeron family or AMD
K6/Athlon/Duron family, or compatible
processor recommended
SVGA 1024x768 pixels resolution.
(1280x1024 pixels resolution
recommended)
150MB free hard-disk space
Memory (free RAM): 128MB (512MB recommended) for 2000 SP4/XP; 512 MB (1 GB
recommended) for Vista, 1 GB (2 GB for 64
bit) for Windows 7 and Windows 8
CD-ROM or DVD drive (only if installing
software from a CD-ROM)
9-pin serial port or USB port for project
transfer to PLC (USB port communications
also requires USB-to-serial converter. Note:
USB-to-serial convertor does not support
XP Mode of Windows 7.)

Navigation Window

Ladder Edit Window

Instruction List
Window

The CLICK Programming Software can be


downloaded free at the AutomationDirect
Web site:
w w w . su ppo r t .a ut o mat i o n di r e ct .co m/
products/clickplcs.html

C0-PGMSW

<--->

The programming software is also


available for purchase on a CD-ROM.

Volume 13

e1-20

Programmable Controllers

1 - 80 0 - 633 - 0405

CLICK Programming Software


Instructions

The easy-to-use instructions are described


in the CLICK programming software
online help file.

Powerful Features!

Company
Information
Systems
Overview
Programmable
Controllers

Address Picker

The Address Picker is a powerful multi-function memory table which can be


used to assign nicknames, create address comments, and establish initial values
for specific memory locations. It can assign specific memory locations to be
retentive during power outages. The Address Picker also has powerful tools for
sorting the memory table and making it easier to use.

CLICK programming software has amazingly powerful features for a free software
product, such as
Address picker
Separate subroutine programs
Separate interrupt programs
Color rung comment feature
Project loader
Documentation is stored within the PLC
memory

Field I/O
Software
C-more &
other HMI
Drives
Soft
Starters
Motors &
Gearbox
Steppers/
Servos
Motor
Controls
Proximity
Sensors
Photo
Sensors
Limit
Switches
Encoders
Current
Sensors
Pressure
Sensors
Temperature
Sensors
Pushbuttons/
Lights

Subroutine Programs

Process

Subroutine programs can be created and


named to isolate a body of program code
that is run selectively. You can run up to
986 subroutine programs.

Relays/
Timers
Comm.
Terminal
Blocks &
Wiring
Power

Interrupt Programs

Circuit
Protection

Interrupt programs are created and


named. The Basic and Standard CPU
modules support up to 12 interrupt
programs. The Analog CPU modules
support up to 8 interrupt programs.

Enclosures
Tools
Pneumatics
Appendix
Product
Index
Part #
Index

Volume 13

w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c

Programmable Controllers

e1-21

CLICK Programming Software


Color Rung Comment

Easily create and edit rung comments with


colors and three text styles. Comments are
stored in the PLC memory for future reference.

Project Loader

The CLICK programming software can


export the CLICK project in an encrypted
format. The exported file can be sent to
the end user. Then the end user can download the file into the CLICK PLC with the
tool called Project Loader.

NOTE: PROJECT LOADER IS A SEPARATE PROGRAM FROM THE CLICK PROGRAMMING SOFTWARE, BUT IT IS INSTALLED
ON THE PC WHEN THE CLICK PROGRAMMING SOFTWARE IS INSTALLED.

Volume 13

e1-22

Programmable Controllers

1 - 80 0 - 633 - 0405

Product Dimensions and Installation


It is important to understand the
installation requirements for your CLICK
system. Your knowledge of these
requirements will help ensure that your
system operates within its environmental
and electrical limits.

Company
Information
Systems
Overview
Programmable
Controllers

Ground Braid
Copper Lugs
Panel or
Single Point
Ground

Panel

Plan for Safety

Star Washers

This catalog should never be used as a


replacement for the user manual.

You can purchase, download free, or view


online the user manuals for these products. Manual C0-USER-M is the user
manual for the CLICK PLC. This user
manual contains important safety information that must be followed. The system
installation should comply with all appropriate electrical codes and standards.

Field I/O
Software
C-more &
other HMI

Star Washers

Drives
Soft
Starters

2 in.
50.8 mm
minimum

Motors &
Gearbox
Steppers/
Servos

2 in.
50.8mm
minimum

Motor
Controls

3 in.
76.2 mm
minimum

Proximity
Sensors
Photo
Sensors
Limit
Switches
Encoders

NOTE: THERE IS A MIMIMUM CLEARANCE REQUIREMENT OF 2 INCHES(51 MM)


BETWEEN THE CLICK PLC AND THE PANEL DOOR OR ANY DEVICES MOUNTED IN THE
PANEL DOOR. THE SAME CLEARANCE IS REQUIRED BETWEEN THE PLC AND ANY SIDE
OF THE ENCLOSURE. A MINIMUM CLEARANCE OF 3 INCHES (76 MM) IS REQUIRED
BETWEEN THE PLC AND A WIREWAY OR ANY HEAT PRODUCING DEVICE.

Current
Sensors
Pressure
Sensors
Temperature
Sensors
Pushbuttons/
Lights
Process
Relays/
Timers
Comm.
Terminal
Blocks &
Wiring
Power
Circuit
Protection

Mounting Orientation

Tools

PORT1
TX1
RX1

STOP

Appendix
TX2
RX2
PORT2

RUN

Pneumatics

PWR
RUN
ERR

CLICK PLCs must be mounted properly to


ensure ample airflow for cooling
purposes. It is important to follow the unit
orientation requirements and to verify that
the PLCs dimensions are compatible with
your application. Notice particularly
the grounding requirements and the
recommended cabinet clearances.

Enclosures

Air
Flow

Part #
Index

Volume 13

w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c

Product
Index

Programmable Controllers

e1-23

Product Dimensions and Installation


Latch tabs

Connecting the Modules


Together

3
Connecting Modules

CLICK CPUs, I/O modules and power


supplies connect together using the extension ports that are located on the side
panels of the modules (no PLC backplane/base required).
1. Remove extension port covers and slide
the latch tabs forward.
2. Align the module pins and connection
plug, and press the I/O module onto the
right side of the CPU.
3. Slide the latch tabs backward to lock the
modules together.

Supports up to eight I/O modules

Mounting

DIN Rail Mounting

Surface Mounting
Upper
Mounting Tab

The CLICK PLC system, which includes the


CLICK power supplies, CPU modules, and
I/O modules, can be mounted in one of
two ways.
1. DIN rail mounted
2. Surface mounted using the built-in
upper and lower mounting tabs.
Pull tab
down.

Unit Dimensions

Power Supply
Module

These diagrams show the outside dimensions of the CLICK power suppy, CPU,
and I/O modules. The CLICK PLC system
is designed to be mounted on standard
35mm DIN rail, or it can be surface
mounted.
Allow proper spacing from
components within an enclosure.

other

Maximum system:

Power Supply + CPU + 8 I/O modules.

2.6
[0.102]

Push tab
up until...

CPU Module

34.9
[1.37]

53.5
[2.11]

Unit Dimensions
mm [inches]

I/O Module
27
[1.06]

Lower
Mounting Tab

Click

13.5
[0.46]

75
[2.95]

85
5
[3.35]
.35]
5

4
[0.16]
"

9.2
[0.36]

9.4
[0.37]

Volume 13

e1-24

Programmable Controllers

1 - 80 0 - 633 - 0405

Product Dimensions and Installation


Unit Dimensions

Company
Information
Systems
Overview
Programmable
Controllers

Power Supply

mm [inches]

Field I/O
Software
C-more &
other HMI
Drives
Soft
Starters
Motors &
Gearbox
Steppers/
Servos
Motor
Controls
Proximity
Sensors

CPU Module

Photo
Sensors
Limit
Switches
Encoders
Current
Sensors
Pressure
Sensors
Temperature
Sensors
Pushbuttons/
Lights
Process
Relays/
Timers
Comm.
Terminal
Blocks &
Wiring

I/O Module

Power
Circuit
Protection
Enclosures
Tools
Pneumatics
Appendix
Product
Index
Part #
Index

Volume 13

w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c

Programmable Controllers

e1-25

Networking the CLICK PLC


Built-in Communications
Ports

Basic CPUs
Port 1 & 2 LED
Status Indicators
TX1 and TX2 (Green)

STOP

On The Comm Port is sending data.


Off The Comm Port is not sending data.

PORT1
TX1
RX1
TX2

RX1 and RX2 (Green)

RX2

On The Comm Port is receiving data.

PORT2

Off The Comm Port is not receiving data.

Port 1, 2, & 3 LED


Status IndicatorsPWR
RUN
ERR
PORT1
TX1

On The Comm Port is sending data.

RX1

Off The Comm Port is not sending data.

TX2
RX2
PORT2

RX1, RX2 and RX3 (Green)


On The Comm Port is receiving data.
Off The Comm Port is not receiving data.

Use: Serial Communication


Physical: 6 pin, RJ12, RS-232
Communication speed (baud):
1200, 2400, 4800, 9600, 19200,
38400, 57600, 115200
Parity: odd, even, none
Station Address: 1 to 247
Data length: 8 bits (Modbus RTU)
or 7, 8 bits (ASCII)
Stop bit: 1,2
Protocol: Modbus RTU
(master/slave) or ASCII in/out

Com Port 3
Specifications

Standard and Analog CPUs

TX1, TX2 and TX3 (Green)

Com Port 2
Specifications

PORT3

RS-485

TX3
RX3

Use: Serial Communication


Physical: 3 pin, RS-485
Communication speed (baud):
1200, 2400, 4800, 9600, 19200,
38400, 57600, 115200
Parity: odd, even, none
Station Address: 1 to 247
Data length: 8 bits (Modbus RTU)
or 7, 8 bits ( ASCII)
Stop bit: 1,2
Protocol: Modbus RTU
(master/slave) or ASCII in/out

Default
-

Com Port 3
Standard and Analog CPUs
Port 1

Port 1 Pin Descriptions

6 pin RJ12 Phone


Type Jack

1
2
3
4
5
6

Port 2

38400
Odd
1

0V
5V
RXD
TXD
NC
0V

Power (-) connection (GND)


Power (+) connection
Receive data (RS-232)
Transmit data (RS-232)
No connection
Power (-) connection (GND)

Port 2 Pin Descriptions

6 pin RJ12 Phone


Type Jack
1

There are LED indicators located to the left


of
each
communication
port
to
indicate when the port is transmitting or
receiving.

Communication speed (baud): 38400 (fixed)


Parity: Odd
Station Address: 1
Data length: 8 bits
Stop bit: 1
Protocol: Modbus RTU (slave only)

Com Port 2

LED Status Indicators

Com Port 1

All CPUs have two built-in RS-232 commuCom Port 1


nications ports. Standard and Analog CPUs
also have one built-in RS-485 communications port. One RS-232 port supports the
Modbus RTU protocol only and can be used
Com Port 2
as the programming port. The other ports
support either Modbus RTU or ASCII
Basic CPU
protocol. Both RS-232 ports supply 5 VDC,
so you can connect a monochrome C-more
Com Port 1 Specifications
Micro HMI panel without an additional Use: Programming Port
power supply.
Physical: 6 pin, RJ12, RS-232

1
2
3
4
5
6

0V
5V
RXD
TXD
RTS
0V

Power (-) connection (GND)


Power (+) connection
Receive data (RS-232)
Transmit data (RS-232)
Request to send
Power (-) connection (GND)

8 bits
1
Modbus
RTU

Default
-

Port 3

RS-485

Port 3 Pin Descriptions


1

+ (plus)

Signal A
(RS-485)

- (minus)

Signal B
(RS-485)

LG

38400
Odd
1

Logic
Ground(0 V)

8 bits
1
Modbus
RTU

Port Setup

Use CLICK programming software to


easily configure the communication
ports.

Volume 13

e1-26

Programmable Controllers

1 - 80 0 - 633 - 0405

Networking the CLICK PLC

Company
Information
Systems
Overview

Typical Serial Communication Applications

Programmable
Controllers

The diagrams on these two pages illustrate the typical uses for the CLICK CPUs communication ports.

Field I/O

Port 1 (RS-232) Modbus RTU Slave Mode Only

Software
C-more &
other HMI
Drives
Soft
Starters

Port 1

Motors &
Gearbox

C-more and C-more


Micro-Graphic Panel
PC
Another CLICK PLC

Other Devices
Supporting Modbus RTU
Master Mode

Steppers/
Servos
Motor
Controls
Proximity
Sensors

CLICK CPU

C-more Micro-Graphic panels (monochrome models only) can get 5 VDC power
from Com port 1 or 2.
Example

CLICK PLC

Photo
Sensors

C-more 3 Inch
Micro-Graphic
Panel

Limit
Switches
Encoders
Current
Sensors

Port 1

Pressure
Sensors

DV-1000CBL
serial cable

Temperature
Sensors

The Color Micro-Graphic panel or the second


Monochrome Micro-Graphic panel needs a separate 24 VDC power source (see the note below).

Pushbuttons/
Lights
Process

Port 1 or 2

NOTE: CLICKS PORT 1 AND PORT 2 CAN PROVIDE 5 VDC TO POWER THE PANEL, BUT NOT AT THE SAME TIME. IF A C-MORE
MICRO-GRAPHIC PANEL IS CONNECTED TO BOTH PORTS, THEN AT LEAST ONE OF THE PANELS MUST BE POWERED BY A C-MORE
MICRO DC POWER ADAPTER, EA-MG-P1 OR EA-MG-SP1, OR ANOTHER 24 VDC POWER SOURCE. COLOR C-MORE MICROGRAPHIC PANELS MUST ALSO BE POWERED FROM A SEPARATE 24 VDC SOURCE.

Do not use the following DirectLOGIC devices with CLICKs Port 1 or 2:

Relays/
Timers
Comm.
Terminal
Blocks &
Wiring
Power
Circuit
Protection
Enclosures

WARNING: The following Direct LOGIC PLC devices cannot be used with a CLICK CPUs Port 1 or Port 2:
Handheld Programmer for DL05, DL06, DL105, DL205 & D3-350 CPUs, p/n D2-HPP
Handheld Programmer for DL405 CPUs, p/n D4-HPP-1
Timer/Counter Access for DL05, DL06, DL105, DL205, DL405 & D3-350 CPUs, p/n DV-1000

Tools
Pneumatics
Appendix
Product
Index

D2-HPP

D4-HPP-1

Part #
Index

DV-1000
Volume 13

w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c

Programmable Controllers

e1-27

Networking the CLICK PLC


Port 2 (RS-232) Modbus RTU or ASCII

Port 3 (RS-485; Standard and Analog CPUs Only) Modbus RTU or ASCII

All CPUs have RS-232 port 2, but only Standard and Analog CPUs have RS-485 port 3.
Ports 2 and 3 allow networking to similar devices.

Port 2
Port 2
Port 3

Modbus RTU
Modbus RTU Master Devices

Standard or Analog CPU

Basic CPU

PC

Another CLICK PLC

See Note on previous page about


connecting a C-more Micro-Graphic
panel to Port 1 or 2.

C-more and C-more


Micro-Graphic Panel

Other Devices
Supporting Modbus RTU
Master Mode

ASCII
Devices that SEND ASCII messages

Barcode
Reader

Other devices
that can send
ASCII data.

Modbus RTU Slave Devices

Weigh Scale
Other Devices
Supporting Modbus
RTU Slave Mode

Devices that RECEIVE ASCII messages

Serial Printer

Serial Text
Display

Other devices
that can receive
ASCII data.

Another CLICK PLC

SOLO Temperature
Controller
(Port 3 Only)

Volume 13

e1-28

Programmable Controllers

1 - 80 0 - 633 - 0405

Power Supplies
Power Supplies

The CLICK PLC family offers two 24 VDC


power supplies. They are identical except
for the output current.

It is not mandatory to use one of these


CLICK power supplies for the CLICK PLC
system. You can use any other 24 VDC
power supply that Automationdirect.com
offers, including the PSP24-DC12-1 12
VDC to 24 VDC converter shown below.

C0-00AC Power Supply

Limited auxiliary AC power supply allows


you to power the 24 VDC CLICK C0 series
CPUs with 100-240 VAC supply power.
The 0.5A DC power supply is capable of
controlling the CPU plus a limited configuration based on the power budget of each
I/O module. The C0-00AC is a low-cost
solution for applications requiring only
minimal I/O and power consumption. This
power supply will not support a fully-populated CLICK PLC system with all possible
I/O module combinations.

C0-01AC Power Supply

Expanded auxiliary AC power supply allows


you to power the 24 VDC CLICK C0 series
CPUs with 100-240 VAC supply power.
The 1.3A DC power supply is capable of
supporting a fully-populated CLICK PLC
system with all possible I/O module
combinations, with no concerns for
exceeding the power budget.

PSP24-DC12-1 DC-DC Converter

With this DC-DC converter you can


operate the CLICK PLC with 12 VDC input
power.

Company
Information
Systems
Overview
Programmable
Controllers

CLICK 24 VDC Power Supply Ratings


Part Number
C0-00AC
C0-01AC

Field I/O

Output Current

Software

0.5 A
1.3 A

C-more &
other HMI

C0-00AC Power Supply Specifications


Input Voltage Range
Input Frequency
Input Current (typical)
Inrush Current
Output Voltage Range
Output Current
Over Current Protection
Weight

85-264 VAC
47-63 Hz.
0.3 A @ 100 VAC, 0.2 A @ 200 VAC
30 A
23-25 VDC
0.5 A
@ 0.65 A (automatic recovery)
5.3 oz (150g)

C0-01AC Power Supply Specifications


Input Voltage Range
Input Frequency
Input Current (typical)
Inrush Current
Output Voltage Range
Output Current
Over Current Protection
Weight

85-264 VAC
47-63 Hz.

Drives
Soft
Starters
Motors &
Gearbox

24 VDC
Output Power
Terminals
(for CLICK PLC, I/O or
field device, etc.)

0.9 A @ 100 VAC, 0.6 A @ 200 VAC

C0-00AC

CLICK Power Supply

Photo
Sensors
Limit
Switches
Encoders
Current
Sensors

PSP24-DC12-1 DC-DC Converter Specifications


Input Voltage Range
Input Power (no load)
Startup Voltage
Undervoltage Shutdown
Output Voltage Range
Output Current
Short Circuit Protection
Weight

Motor
Controls
Proximity
Sensors

85-264 VAC
Power Source
Input Terminals

30 A
23-25 VDC
1.3 A
@ 1.6 A (automatic recovery)
6.0 oz (170g)

Steppers/
Servos

Pressure
Sensors

9.5-18 VDC
1.0 W max.

Temperature
Sensors

8.4 VDC
7.6 VDC
24-28 VDC (adjustable)
1.0 A
Current limited at 110% typical
7.5. oz (213g)

Pushbuttons/
Lights
Process

CLICK CPU

24 VDC
Output Power
Terminals
(for CLICK PLC, I/O or
field device, etc.)

C0-01AC

Relays/
Timers
Comm.

85-264 VAC
Power Source
Input Terminals

Terminal
Blocks &
Wiring
Power
Circuit
Protection
Enclosures
Tools
Pneumatics

24V
0V
PSP24-DC12-1

24 VDC power is supplied to the CPU


module through wiring connected from
the power supply output to the 4-pin 24
VDC input connector located on the bottom of the CPU module.

Volume 13

w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c

Programmable Controllers

e1-29

Appendix
Product
Index
Part #
Index

Power Budgeting
Power Budgeting

There are two areas to be considered


when determining the power required to
operate a CLICK PLC system. The first
area is the power required by the CLICK CLICK 24 VDC Power
Other 24 VDC Power
Supply
CPU, along with the internal logic side
Supply
C0-00AC or C0-01AC
Example: PSP24-60S
power that the CPU provides to its own
I/O and any connected I/O modules that
CPU Current Consumption (mA)
are powered through the CPUs expansion
Power Budget External
port; plus any device, such as a C-more
Part Number
24 VDC
24 VDC
Micro-Graphic panel, that is powered
(logic side) (field side)
through one of the CPUs communication
Basic CPU Modules
ports.
120
60
C0-00DD1-D
The second area is the power required by
120
0
C0-00DD2-D
all externally connected I/O devices. This
120
0
C0-00DR-D
should be viewed as the field side power
120
0
C0-00AR-D
required. The field side power is depenStandard CPU Modules
dent on the voltage used for a particular
140
60
C0-01DD1-D
input or output device as it relates to the
140
0
C0-01DD2-D
wired I/O point, and the calculated load
140
0
C0-01DR-D
rating of the connected device.
140
0
C0-01AR-D
Analog
CPU
Modules
It is strongly recommended that the power
140
60
C0-02DD1-D
source for the logic side be separate from
140
0
C0-02DD2-D
the power source for the field side to help
140
0
C0-02DR-D
eliminate possible electrical noise.
Power budgeting requires the calculation
of the total current that the 24 VDC power
source needs to provide to CLICKs logic
side, and also a separate calculation of
the total current required for all devices
operating from the field side of the PLC
system.

See the Power Budgeting Example shown


to the right. The table shows current
requirements for a CLICK CPU, two I/O
modules, and a C-more Micro. Use the
total amperage values to select a proper
sized power supply.

Power Budgeting Using the


CLICK Programming Software

The CLICK Programming software can


also be used for power budgeting. Based
on the amperage rating of the
power supply selected in the
first column, your power
budget is calculated by
subtracting each consecutive
modules power consumption
from the total available power
budget. If you exceed the
maximum allowable power
consumption
the
power
budget row is highlighted in
red.

I/O Module Current Consumption (mA)


Power Budget External
24 VDC
24 VDC
(logic side) (field side)
Discrete Input Modules
30
0
C0-08ND3
30
0
C0-08ND3-1
40
0
C0-16ND3
30
0
C0-08NE3
40
0
C0-16NE3
30
0
C0-08NA
Discrete Output Modules
50
15
C0-08TD1
50
0
C0-08TD2
80
100
C0-16TD1
80
0
C0-16TD2
80
0
C0-08TA
100
0
C0-04TRS
100
0
C0-08TR
Part Number

I/O Module Current Consumption


(continued) (mA)
Power Budget External
24 VDC
24 VDC
(logic side) (field side)
Discrete Combo I/O Modules
80
50
C0-16CDD1
80
0
C0-16CDD2
80
0
C0-08CDR
Analog Input Modules
20
65
C0-04AD-1
23
65
C0-04AD-2
25
0
C0-04RTD
25
0
C0-04THM
Analog Output Modules
20
145
C0-04DA-1
20
85
C0-04DA-2
Analog Combo I/O Modules
25
75
C0-4AD2DA-1
20
65
C0-4AD2DA-2
C-more Micro-Graphic Panel
Monochrome
90
0
only
Part Number

Power Budgeting Example

Current Consumption (mA) Example


Part Number
C0-00DD1-D
C0-16ND3
C0-16TD1
C-more Micro
Total:

Power Budget External


24 VDC
24 VDC
(logic side) (field side)
120
40
80
90
330

60
0
100
0
160 *

* Plus calculated load of connected I/O devices.


Power Supply
(C0-01AC)

CPU Module
(C0-00DD1-D)

I/O Module
(C0-16ND3)
I/O Module
(C0-16TD1)

Port 1
or
Port 2

C-more
Micro-Graphic
Panel
Only monochrome models
can be powered from port 1 or 2.

Volume 13

e1-30

Programmable Controllers

1 - 80 0 - 633 - 0405

Choosing the I/O Type


Three types of CPU modules are available:
Basic CPUs with discrete-only inputs and
outputs.
Standard CPUs with discrete-only inputs
and outputs, plus an extra communications port and battery backup.
Analog CPUs with both discrete and analog inputs and outputs, plus an extra communications port and battery backup.

All CLICK CPU modules offer the same


performance, use the same instruction set,
and support all optional I/O modules.

Basic and Standard CPU


Modules

The Basic and Standard CLICK CPU


modules are available with different
combinations of built-in I/O types (i.e. DC
input/DC output, DC input/relay output,
and AC input/relay output). With the 14
built-in I/O points (8 inputs/6 outputs), the
CPU can be used as a ready-to-go PLC
control system without any additional I/O
modules. The CPU module just needs 24
VDC, but it can be expanded in the future
if the need arises.
The tables list the part numbers showing
the various I/O type combinations.

Company
Information
Systems
Overview

PLC Mode
Switch

C0-00DD1-D

8 Discrete
Input
Points

LED Status
Indicators

Field I/O
Software
C-more &
other HMI
Drives
Soft
Starters

Communication
Ports

6 Discrete
Output
Points

Motors &
Gearbox
Steppers/
Servos
Motor
Controls
Proximity
Sensors

Basic CLICK CPUs


Part Number
C0-00DD1-D
C0-00DD2-D
C0-00DR-D
C0-00AR-D

Discrete Input Type

Discrete Output Type

8 DC (sink/source)

6 DC (sink)
6 DC (source)

External Power
24V DC (required
for all CPUs)

6 Relay

8 AC

Standard CPU Modules Only

Standard CPU modules also have an


RS-485 port for Modbus and ASCII
communications, and the battery backup
feature which will retain the data in SRAM
for 5 years (battery sold separately; part
no. D2-BAT-1).

Programmable
Controllers

Basic CPU

8 Discrete
Input
Points

PWR
ERR

Pushbuttons/
Lights

Relays/
Timers

PORT1
TX1
RX1
TX2

6 Discrete
Output
Points

RX2
PORT2

PORT3

Temperature
Sensors

Process

RUN

Communication
Ports

Encoders

Pressure
Sensors
C0-01DD1-D

LED Status
Indicators

Limit
Switches

Current
Sensors

Standard CPU

PLC Mode
Switch

Photo
Sensors

RS-485

Comm.
Terminal
Blocks &
Wiring
Power

TX3
RX3

Circuit
Protection
Enclosures
Tools

Standard CLICK CPUs


Part Number
C0-01DD1-D
C0-01DD2-D
C0-01DR-D
C0-01AR-D

Discrete Input Type

Discrete Output Type

8 DC (sink/source)

6 DC (sink)
6 DC (source)

8 AC

External Power
24V DC (required
for all CPUs)

6 Relay

Pneumatics
Appendix
Product
Index
Part #
Index

Volume 13

w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c

Programmable Controllers

e1-31

Choosing the I/O Type


Analog CPU Modules

The Analog CLICK CPU modules are


available with different combinations of
DC in, DC sinking, sourcing or relay out,
and analog in and out.

They also have an RS-485 port for


Modbus and ASCII communications, and
the battery backup feature which will
retain the data in SRAM for 5 years
(battery sold separately; part no.
D2-BAT-1).
The table lists the part numbers showing
the various I/O type combinations.

Analog CPU
PLC Mode
Switch

C0-02DD1-D
C1
X1
X2

4 Discrete
Inputs

X3

LED Status
Indicators

PWR

X4

RUN

C2

ERR

Y1
Y2

PORT1

Y3

TX1

Y4

RX1

+V
AD1V

Communication
Ports

TX2

AD1 I

RX2

AD2V

PORT2

4 Discrete
Outputs
2 Analog
Inputs

AD2 I
ACOM

RS-485

PORT3

DA1V

TX3

DA1 I

RX3

DA2V

2 Analog
Outputs

DA2 I

Analog CLICK CPUs


Discrete
Discrete
Part Number Input
Types Output Types
4 DC (sink)
C0-02DD1-D
4 DC
C0-02DD2-D (sink/source) 4 DC (source)
4 relay
C0-02DR-D

Analog Input
Types
2 channel; voltage (0-5
VDC) / current (4-20
mA); selectable
separately per channel;
12 bit

Analog Output
Types

External
Power

2 channel; voltage (0-5


VDC) / current (4-20
24 VDC (required
mA); selectable
separately per channel; for all CPUs)
12 bit

I/O Modules

A variety of discrete, combo, and analog


I/O modules are available for the CLICK
PLC system. Up to eight I/O modules can
be connected to a CLICK
CPU module to expand the
system I/O count and meet
the needs of a specific
application. Complete I/O
module specifications and
wiring diagrams can be
found later in this section.

C0-08ND3

Discrete Input Modules

C0-08ND3-1

C0-16ND3

C0-08NE3

C0-16NE3

C0-08NA

Discrete Input Modules


Part Number
C0-08ND3
C0-08ND3-1
C0-16ND3
C0-08NE3
C0-16NE3
C0-08NA

I/O Type/
Number/Commons

Sink or
Source

Voltage
Ratings

DC/8/2
DC/8/2
DC/16/4
AC/DC / 8/2
AC/DC / 16/4
AC/8/2

Sink or Source
Sink or Source
Sink or Source
Sink or Source
Sink or Source
N/A

12-24 VDC
3.3-5 VDC
24 VDC
24 VAC/VDC
24 VAC/VDC
100-120 VAC

Volume 13

e1-32

Programmable Controllers

1 - 80 0 - 633 - 0405

Choosing the I/O Type


Discrete I/O Modules
(continued)

Company
Information
Systems
Overview
Programmable
Controllers
Field I/O

Discrete Output Modules

Software
C-more &
other HMI
Drives
Soft
Starters
Motors &
Gearbox
Steppers/
Servos
Motor
Controls

C0-08TD1

C0-16TD1

C0-08TD2

C0-16TD2

C0-08TA

C0-04TRS

C0-08TR

Discrete Output Modules


I/O Type/
Number/ Commons

Sink or
Source

Voltage/Current
Ratings

C0-08TD1
C0-08TD2
C0-16TD1
C0-16TD2
C0-08TA

DC/8/2
DC/8/1
DC/16/2
DC/16/2
AC/8/2

Sink
Source
Sink
Source
N/A

C0-04TRS

Relay/4/4

N/A

C0-08TR

Relay/8/2

N/A

3.3-27 VDC, 0.3 A


12-24 VDC, 0.3 A
5-27 VDC, 0.1 A
12-24 VDC, 0.1 A
17-240 VAC, 0.3 A
6-27 VDC, 7 A
6-240 VAC, 7 A
6-27 VDC, 1 A
6-240 VAC, 1 A

Part Number

Photo
Sensors
Limit
Switches
Encoders
Current
Sensors
Pressure
Sensors
Temperature
Sensors

Discrete Combo I/O Modules


PWR

C0-16CDD1
24V

C0-16CDD2
24V

C0-16CDD1

12-24V

2.5-5mA

C1
1
2
3
4
C2
1
2
3
4
30V

0.1A

C0-16CDD2

Process

C0-08CDR

Relays/
Timers

250V 1A

Comm.
Terminal
Blocks &
Wiring

OUTPUT

12-24V

0.1A

PWR

OUTPUT

5
6
7
8
+V
1
2
3
4
C2
5
6
7
8

4mA

INPUT

C1
1
2
3
4

Pushbuttons/
Lights

INPUT

5-27V

PWR

OUTPUT

5
6
7
8
C2
1
2
3
4
+V
5
6
7
8

4mA

INPUT

C1
1
2
3
4

Power
Circuit
Protection

1A

50-60Hz

Enclosures

C0-08CDR

Tools

Discrete Combo I/O Modules


Part
Number

Input Type

Input Voltage

Output Type

C0-16CDD1

8 DC (source/sink)

24 VDC

8 DC (sink)

C0-16CDD2

8 DC (source/sink)

24 VDC

8 DC (source)

C0-08CDR

4 DC (source/sink)

12-24 VDC

4 (relay)

Pneumatics

Output Voltage /
Current Ratings

Appendix
Product
Index

5-27 VDC /
0.1 A
12-24 VDC /
0.1 A
6.25-24 VDC, 1 A
6-240 VAC, 1 A

Part #
Index

Volume 13

w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c

Proximity
Sensors

Programmable Controllers

e1-33

Choosing the I/O Type


Analog I/O Modules

Analog Input Modules


C0-04AD-1

0-20mA

C0-04AD-2

0-10V

INPUT

CH1
CH2
CH3
CH4
0V
0V
0V
0V
0V
24V
0V

C0-04AD-2

J,K,E,R,S,T,B,N,C,mV

COM
R1+
R1
R1C
COM
COM
R2+
R2
R2C
COM
COM
R3+
R3
R3C
COM
COM
R4+
R4
R4C
COM

INPUT

C0-04AD-1

C0-04THM

Pt, Cu, Ni, RES

INPUT

INPUT
CH1
CH2
CH3
CH4
0V
0V
0V
0V
0V
24V
0V

C0-04RTD

COM
TC1+
TC1
TC2+
TC2
COM
TC3+
TC3
TC4+
TC4
COM

C0-04RTD

C0-04THM

Analog Input Modules


Part
Number
C0-04AD-1
C0-04AD-2
C0-04RTD
C0-04THM

External Power
Required

Analog Input Types


4 channel, current (0-20 mA), 13 bit
4 channel, voltage (0-10 V), 13 bit
4 channel RTD input (0.1 degree C/F
resolution), or resistive input (0 to 3125 ohms)
4 channel thermocouple input (0.1 degree C/F
resolution), or voltage input (-156.25 mV to 1.25 V), 16 bit

24 VDC
24 VDC
None
None

Analog Output Modules


C0-04DA-1

4-20mA

C0-04DA-2

0-10V

C0-04DA-1

OUTPUT

OUTPUT
CH1
CH2
CH3
CH4
0V
0V
0V
0V
0V
24V
0V

CH1
CH2
CH3
CH4
0V
0V
0V
0V
0V
24V
0V

C0-04DA-2

Analog Output Modules


Part Number
C0-04DA-1
C0-04DA-2

Analog Output Types

External Power
Required

4 channel, current sourcing (4-20 mA), 12 bit


4 channel, voltage (0-10 V), 12 bit

24 VDC
24 VDC

Volume 13

e1-34

Programmable Controllers

1 - 80 0 - 633 - 0405

Choosing the I/O Type / Specifications


Analog I/O Modules
(continued)

Company
Information
Systems
Overview
Programmable
Controllers

Analog Combo I/O Modules


C0-4AD2DA-1

Field I/O
Software
C-more &
other HMI

C0-4AD2DA-2

0-20mA In
4-20mA Out

0-10V

CH1
0V

CH1
0V

Drives

INPUT

INPUT

CH2
0V

CH2
0V

CH3
0V

CH3
0V

CH4
0V

CH4
0V

CH1
0V

CH1
0V

Soft
Starters

OUTPUT

OUTPUT

Motors &
Gearbox

CH2
0V

CH2
0V

24V
0V

24V
0V

C0-4AD2DA-1

Steppers/
Servos
Motor
Controls

C0-4AD2DA-2

Proximity
Sensors

Analog Combo I/O Modules


Part Number
C0-4AD2DA-1
C0-4AD2DA-2

Analog Input Type

Analog Output Type

4 channel, current (0-20 mA), 2 channel, current sourcing


13 bit
(4-20 mA), 12 bit
4 channel, voltage (0-10 V),
4 channel, voltage
13 bit
(0-10 V), 12 bit

Photo
Sensors

External Power
Required

Limit
Switches

24 VDC

Encoders

24 VDC

Current
Sensors

General Specifications
For All CLICK PLC
Products

These general specifications apply to all


CLICK CPUs, optional I/O modules, and
optional power supply products. Please
refer to the appropriate I/O temperature
derating charts under both the CPU and
I/O module specifications to determine
best operating conditions based on the
ambient temperature of your particular
application.

Pressure
Sensors

General Specifications
Power Input Voltage Range
Maximum Power Consumption
Maximum Inrush Current
Acceptable External Power Drop
Operating Temperature
Storage Temperature
Ambient Humidity
Environmental Air
Vibration
Shock
Noise Immunity
Emissions
Agency Approvals
Other

20-28 VDC
5 W (No 5 V use from communication port)
30 A (less than 1ms)
Max 10 ms
Analog, analog combo I/O modules only: 32F to 140F (0C to 60C);
All other modules: 32F to 131F (0C to 55C), IEC 60068-2-14 (Test
Nb, Thermal Shock)
4F to 158F (20C to 70C)
IEC 60068-2-1 (Test Ab, Cold)
IEC 60068-2-2 (Test Bb, Dry Heat)
IEC 60068-2-14 (Test Na, Thermal Shock)
30% to 95% relative humidity (noncondensing)
No corrosive gases. Environmental pollution level is 2 (UL840)
MIL STD 810C, Method 514.2, EC60068-2-6
JIS C60068-2-6 (Sine wave vibration test)
MIL STD 810C, Method 516.2, IEC60068-2-27, JIS C60068-2-27
Comply with NEMA ICS3-304, Impulse noise 1s, 1000V
EN61000-4-2 (ESD), EN61000-4-3 (RFI), EN61000-4-4 (FTB)
EN61000-4-5 (Surge), EN61000-4-6 (Conducted)
EN61000-4-8 (Power frequency magnetic field immunity)
RFI: No interference measured at 150 and 450 MHz (5w/15cm)
EN55011:1998 Class A
UL508 (File No. E157382, E316037); CE (EN61131-2)
RoHS

Temperature
Sensors
Pushbuttons/
Lights
Process
Relays/
Timers
Comm.
Terminal
Blocks &
Wiring
Power
Circuit
Protection
Enclosures
Tools
Pneumatics
Appendix
Product
Index
Part #
Index

Volume 13

w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c

Programmable Controllers

e1-35

CLICK Specifications
CPU Module
Specifications
CPU Module Specifications
Basic CPU
Control Method
I/O Numbering System
Ladder Memory (steps)
Total Data Memory (words)
Contact Execution (boolean)
Typical Scan (1k boolean)
RLL Ladder Style Programming
Run Time Edits
Scan
CLICK Programming Software for
Windows
Built-in Communication Ports
FLASH Memory
Built-in Discrete I/O points
Built-in Analog I/O Channels
Number of Instructions Available
Control Relays
System Control Relays
Timers
Counters
Interrupt
Subroutines
For/Next Loops
Math (Integer and Hex)
Drum Sequencer Instruction
Internal Diagnostics
Password Security
System Error Log
User Error Log
Memory Backup
Battery Backup
Calendar/Clock
I/O Terminal Block Replacement
Communication Port & Terminal
Block Replacement
24 VDC Power Terminal Block
Replacement

Standard CPU

Analog CPU

Stored Program/Cyclic execution Stored Program/Cyclic execution Stored Program/Cyclic execution


method
method
method
Fixed in Decimal
8000
8000
< 0.6us
1-2 ms
Yes
No
Variable / fixed

Fixed in Decimal
8000
8000
< 0.6us
1-2 ms
Yes
No
Variable / fixed

Fixed in Decimal
8000
8000
< 0.6us
1-2 ms
Yes
No
Variable / fixed

Yes

Yes

Yes

Yes (two RS-232 ports)

Yes (two RS-232 ports and one


RS-485 port)

Yes (two RS-232 ports and one


RS-485 port)

Standard on CPU
8 inputs, 6 outputs
No
21
2000
1000
500
250
Yes (external: 8 / timed: 4)
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Super Capacitor

No
ADC p/n C0-16TB

Standard on CPU
8 inputs, 6 outputs
No
21
2000
1000
500
250
Yes (external: 8 / timed: 4)
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Super Capacitor + Battery
Yes (battery sold separately;
part # D2-BAT-1)
Yes
ADC p/n C0-16TB

Standard on CPU
4 inputs, 4 outputs
2 inputs, 2 outputs
21
2000
1000
500
250
Yes (external: 4 / timed: 4)
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Super Capacitor + Battery
Yes (battery sold separately;
part # D2-BAT-1)
Yes
ADC p/n C0-16TB

N/A

ADC p/n C0-03TB

ADC p/n C0-03TB

ADC p/n C0-4TB

ADC p/n C0-4TB

ADC p/n C0-4TB

No

Volume 13

e1-36

Programmable Controllers

1 - 80 0 - 633 - 0405

CLICK Specifications
CPU Features

Company
Information
Systems
Overview
Programmable
Controllers

Basic CPUs

Standard CPUs
Mounting
Tab
Sliding
Latch

PLC Mode
Switch

8 Discrete
Input
Points

LED Status
Indicators

Field I/O

Mounting
Tab

PLC Mode
Switch

C0-01DD1-D

LED Status
Indicators

PWR

Software

Sliding
Latch

C-more &
other HMI

8 Discrete
Input
Points

Soft
Starters
Motors &
Gearbox

RUN
ERR
PORT1

Steppers/
Servos

TX1
RX1

Communication
Ports

6 Discrete
Output
Points

Communication
Ports

TX2

6 Discrete
Output
Points

RX2
PORT2

PORT3

RS-485

TX3
RX3

Sliding
Latch

Power
Terminal
24V
0V
N.C.
G

Mounting
Tab

Sliding
Latch
Power
Terminal
24V
0V
N.C.
G

Mounting
Tab

C0-02DD1-D
X1
X2
X3
PWR

X4

RUN

C2

ERR

Y1
Y2

PORT1

Y3

TX1

Y4

RX1

+V
AD1V

TX2

AD1II
AD1

RX2

AD2V

PORT2

PORT3

Sliding
Latch

Encoders

Process

4 Discrete
Inputs

Relays/
Timers

4 Discrete
Outputs
2 Analog
Inputs

Power
al
Terminal
24V
0V
N.C.
G

Comm.
Terminal
Blocks &
Wiring
Power

ACOM

Circuit
Protection

DA1V

TX3

DA1II
DA1

RX3

DA2V

2 Analog
Outputs

Enclosures
Tools

DA2II
DA2

Power
Terminal
24V
0V
N.C.
G

Limit
Switches

Pushbuttons/
Lights

AD2II
AD2
RS-485

Photo
Sensors

Temperature
Sensors

Bottom of CPU
(Same on all models)

C1

Communication
Ports

Proximity
Sensors

Pressure
Sensors

Mounting
Tab

LED Status
Indicators

Motor
Controls

Current
Sensors

Analog CPUs

PLC Mode
Switch

Drives

Sliding
Latch

Pneumatics
Appendix

Mounting
Tab

Product
Index
Part #
Index

Volume 13

w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c

Programmable Controllers

e1-37

CLICK Specifications
CPU LED Status Indicators
BasicCPUs
CPU
Basic

POWER LED (Green)


On

Power Good

Off

Power Failure

RUN LED (Green)


On

CPU Run Mode

Initializing
Blink System
CPU Program
Off Mode

INPUT LEDs (Green)


On

Input True

Off

Input False

ERROR LED (RED)


Self Diagnostic
Error
Self
Diagnostic
Blink Warning
On

Off

OUTPUT LEDs (Red)

No Error

TX & RX LED (Green)


On Comm Port Data Active

On

Output True

Off

Output False

Off No Communication

Standard CPU
Standard
CPUs

POWER LED (Green)


On

Power Good

Off

Power Failure
C0-01DD1-D

RUN LED (Green)


On

CPU Run Mode

Initializing
Blink System
CPU Program
Off Mode
ERROR LED (RED)
Self Diagnostic
Error
Self
Diagnostic
Blink Warning
On

Off

No Error

TX & RX LED (Green)


On Comm Port Data Active

INPUT LEDs (Green)

PWR
RUN
ERR

On

Input True

Off

Input False

PORT1
TX1
RX1
TX2
RX2

OUTPUT LEDs (Red)

PORT2

PORT3
TX3
RX3

RS-485

On

Output True

Off

Output False

Off No Communication

Analog CPU

Analog CPUs

POWER LED (Green)


On

Power Good

Off

Power Failure

RUN LED (Green)


On

C1

CPU Run Mode

Initializing
Blink System
CPU Program
Off Mode
ERROR LED (RED)
Diagnostic
On Self
Error
Self
Diagnostic
Blink Warning
Off

C0-02DD1-D

No Error

TX & RX LED (Green)


On Comm Port Data Active

X1
X2

INPUT LEDs (Green)


On

Input True

Off

Input False

X3
PWR

X4

RUN

C2

ERR

Y1
Y2

PORT1

Y3

TX1

Y4

RX1

+V

OUTPUT LEDs (Red)


On

Output True

Off

Output False

AD1V
TX2

AD1 I

RX2

AD2V

PORT2

PORT3

AD2 I
RS-485

ACOM
DA1V

TX3

DA1 I

RX3

DA2V

Off No Communication

DA2 I

Volume 13

e1-38

Programmable Controllers

1 - 80 0 - 633 - 0405

CLICK Specifications

Company
Information
Systems
Overview
Programmable
Controllers

I/O Module LED Status Indicators

Field I/O

I/O Module LED Status Indicators

Software

POWER LED (Green)

C-more &
other HMI

I/O Module LED Status Indicators

On

Power Good

Off

Power Failure

Drives
Soft
Starters
Motors &
Gearbox
Steppers/
Servos

OUTPUT LEDs (Red)

INPUT LEDs (Green)


On

Input True

Off

Input False

On

Output True

Off

Output False

Motor
Controls

Note: There are no LED indications


on the Analog I/O modules.

Input I/O Module

Encoders
Current
Sensors
Pressure
Sensors

11-pin Terminal Block Specifications

Screw Torque
ADC Part Number

Temperature
Sensors

Pluggable Terminal Block


11 pt
3.50 mm
28-16 AWG
7 mm
M2.0
Analog, analog combo I/O
modules only: 1.7 lb-in;
All other modules: 2.0 to 2.2 lb-in
C0-8TB

Pushbuttons/
Lights
Process
Relays/
Timers
Comm.
Terminal
Blocks &
Wiring

11-Pin Terminal Block,


C0-8TB

Power

20-pin Terminal Block Specifications


Connector Type
Number of Pins
Pitch
Wire Range
Wire Strip Length
Screw Size
Screw Torque
ADC Part Number

Circuit
Protection

Pluggable Terminal Block


20 pt
3.50 mm
28-16 AWG
7 mm
M2.0
Analog, analog combo I/O
modules only: 1.7 lb-in;
All other modules: 2.0 to 2.2 lb-in
C0-16TB

Enclosures
Tools
Pneumatics
Appendix
Product
Index

20-Pin Terminal Block,


C0-16TB

Part #
Index

Volume 13

w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c

Photo
Sensors
Limit
Switches

Output I/O Module

I/O Terminal Block Specifications for CPUs and I/O Modules


Connector Type
Number of Pins
Pitch
Wire Range
Wire Strip Length
Screw Size

Proximity
Sensors

Programmable Controllers

e1-39

Wiring System for CLICK PLCs


Wiring Solutions using the ZIPLink Wiring
System

ZIPLinks eliminate the normally tedious process of wiring between devices


by utilizing prewired cables and DIN rail mount connector modules. It's as
simple as plugging in a cable connector at either end or terminating wires
at only one end. Prewired cables keep installation clean and efficient,
using half the space at a fraction of the cost of standard terminal blocks.

ZIPLinks are available in a variety of styles to suit your needs, including


feedthrough connector module. ZIPLinks are available for all Basic and
Standard CLICK CPU modules and most discrete and analog I/O modules.
Pre-printed I/O-specific adhesive label strips for quick marking of ZIPLink
modules are provided with ZIPLink cables.

Solution 1: CLICK CPU and I/O Modules to ZIPLink


Connector Modules

When looking for quick and easy I/O-to-field termination, a ZIPLink


connector module used in conjunction with a prewired ZIPLink cable,
consisting of an I/O terminal block at one end and a multi-pin connector
at the other end, is the best solution.

Using the PLC CPU and I/O Modules to ZIPLink


Connector Modules selector tables located in this section,
1. Locate your CPU or I/O module.
2. Select a ZIPLink Module.
3. Select a corresponding ZIPLink Cable.

When wanting to connect I/O to another device within close proximity of


the I/O modules, no extra terminal blocks are necessary when using the
ZIPLink Pigtail Cables. ZIPLink Pigtail Cables are prewired to an I/O
terminal block with color-coded pigtail with soldered-tip wires on the other
end.

Using the I/O Modules to 3rd Party Devices selector tables


located in the ZIPLink section,
1. Locate your CPU or I/O module.
2. Select a ZIPLink Pigtail Cable that is compatible
with your 3rd party device.

Solution 2: CLICK CPU and I/O Modules to 3rd Party


Devices

Solution 3: GS Series and DuraPulse Drives


Communication Cables

Need to communicate via Modbus RTU to a drive or a network of


drives?

ZIPLink cables are available in a wide range of


configurations for connecting to PLCs and SureServo, SureStep, Stellar
Soft Starter and AC drives. Add a ZIPLink communications module to
quickly and easily set up a multi-device network.

Solution 4: Serial Communications Cables

ZIPLink offers communications cables for use with CLICK CPUs that can
also be used with other communications devices. Connections include
a 6-pin RJ12 connector which can be used in conjunction with the RJ12
Feedthrough module.

Using the Drives Communication selector tables


located in the ZIPLink section,
1. Locate your Drive and type of communications.
2. Select a ZIPLink cable and other associated hardware.

Using the Serial Communications Cables selector


table located in the ZIPLink section,
1. Locate your connector type
2. Select a cable.

Volume 13

e1-40

Programmable Controllers

1 - 80 0 - 633 - 0405

Wiring System for CLICK PLCs

Company
Information
Systems
Overview
Programmable
Controllers

CLICK PLC CPU Module ZIPLink Selector


PLC
ZIPLink
CPU
Module

# of Terms Component

C0-00DD1-D
C0-00DD2-D
C0-00DR-D
C0-00AR-D
C0-01DD1-D
C0-01DD2-D
C0-01DR-D
C0-01AR-D
C0-02DD1-D
C0-02DD2-D
C0-02DR-D

20
20
20
20
20
20
20
20
20
20
20

Feedthrough
Feedthrough
Feedthrough
Feedthrough
Feedthrough
Feedthrough
Feedthrough
Feedthrough

Module Part Cable Part


No.
No.
ZL-RTB20
ZL-RTB20
ZL-RTB20
ZL-RTB20
ZL-RTB20
ZL-RTB20
ZL-RTB20
ZL-RTB20

ZL-C0-CBL20*
ZL-C0-CBL20*
ZL-C0-CBL20*
ZL-C0-CBL20*
ZL-C0-CBL20*
ZL-C0-CBL20*
ZL-C0-CBL20*
ZL-C0-CBL20*

No ZIPLinks are available for analog CPU modules.

CLICK PLC Discrete Input Module ZIPLink Selector


I/O Module
ZIPLink
Input
Module

# of
Terms

Part
Component Module
No.

Cable Part
No.

C0-08ND3
C0-08ND3-1
C0-08NE3
C0-08NA

11
11
11
11

C0-16ND3

20

C0-16NE3

20

Feedthrough
Feedthrough
Feedthrough
Feedthrough
Feedthrough
Sensor
Feedthrough
Sensor

ZL-C0-CBL11*
ZL-C0-CBL11*
ZL-C0-CBL11*
ZL-C0-CBL11*
ZL-C0-CBL20*
ZL-C0-CBL20*
ZL-C0-CBL20*
ZL-C0-CBL20*

ZL-RTB20
ZL-RTB20
ZL-RTB20
ZL-RTB20
ZL-RTB20
ZL-LTB16-24
ZL-RTB20
ZL-LTB16-24

CLICK PLC Combo I/O Module ZIPLink Selector


I/O Module
ZIPLink
Combo
Module

# of Terms Component

Module Part Cable Part


No.
No.

C0-16CDD1
C0-16CDD2
C0-08CDR

20
20
11

ZL-RTB20
ZL-RTB20
ZL-RTB20

Feedthrough
Feedthrough
Feedthrough

ZL-C0-CBL20*
ZL-C0-CBL20*
ZL-C0-CBL11*

CLICK PLC Analog I/O Module ZIPLink Selector


I/O Module
ZIPLink
Analog
Module

# of
Terms

Module Part
Component No.

Cable Part
No.

C0-04AD-1
C0-04AD-2
C0-04RTD
C0-04THM
C0-04DA-1
C0-04DA-2
C0-4AD2DA-1
C0-4AD2DA-2

11
11
20
11
11
11
20
20

Feedthrough
Feedthrough

ZL-C0-CBL11*
ZL-C0-CBL11*

ZL-RTB20
ZL-RTB20

No ZIPLinks are available for RTD and thermocouple


modules.
Feedthrough
Feedthrough
Feedthrough
Feedthrough

ZL-RTB20
ZL-RTB20
ZL-RTB20
ZL-RTB20

ZL-C0-CBL11*
ZL-C0-CBL11*
ZL-C0-CBL20*
ZL-C0-CBL20*

* Select the cable length by replacing the * with: Blank = 0.5m, -1 = 1.0m,
or -2 = 2.0m.

# of Terms Component

C0-08TD1
C0-08TD2
C0-08TR
C0-08TA

11
11
11
11

C0-16TD1

20

C0-16TD2

20

C0-04TRS1

20

Feedthrough
Feedthrough
Feedthrough
Feedthrough
Feedthrough
Fuse
Relay (sinking)
Feedthrough
Fuse
Relay (sourcing)
Feedthrough

Drives
Soft
Starters
Motors &
Gearbox
Steppers/
Servos
Motor
Controls
Proximity
Sensors
Photo
Sensors
Limit
Switches
Encoders

Temperature
Sensors
Pushbuttons/
Lights
Process
Relays/
Timers

ZL-C0-CBL11*
ZL-C0-CBL11*
ZL-C0-CBL11*
ZL-C0-CBL11*
ZL-C0-CBL20*
ZL-C0-CBL20*
ZL-C0-CBL20*
ZL-C0-CBL20*
ZL-C0-CBL20*
ZL-C0-CBL20*
ZL-C0-CBL20*

Comm.
Terminal
Blocks &
Wiring
Power
Circuit
Protection
Enclosures
Tools

1 Note: The C0-04TRS relay output is derated not to exceed 2A per point maximum

Pneumatics

when used with the ZIPLink wiring system.


2 Note: Fuses (5 x 20 mm) are not included. See Edison Electronic Fuse section for

Appendix

(5 x 20 mm) fuse. S500 and GMA electronic circuit protection for fast-acting maximum protection. S506 and GMC electronic circuit protection for time-delay performance. Ideal for inductive circuits.
To ensure proper operation, do not exceed the voltage and current rating of
ZIPLink module. ZL-RFU20 = 2A per circuit.

Product
Index
Part #
Index

Volume 13

w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c

C-more &
other HMI

Pressure
Sensors

Module Part Cable Part


No.
No.
ZL-RTB20
ZL-RTB20
ZL-RTB20
ZL-RTB20
ZL-RTB20
ZL-RFU202
ZL-RRL16-24-1
ZL-RTB20
ZL-RFU202
ZL-RRL16-24-2
ZL-RTB20

Software

Current
Sensors

CLICK PLC Discrete Output Module ZIPLink Selector


I/O Module
ZIPLink
Output
Module

Field I/O

Programmable Controllers

e1-41

Basic CPU Module Specifications


C0-00DD1-D

<--->

C0-00DD1-D Built-in I/O Specifications - Inputs


Inputs per Module
Operating Voltage Range
Input Voltage Range

8 DC Input/6 Sinking DC Output Micro PLC

Input Current

Wiring Diagram
C0-00DD1-D

8 (Sink/Source)
24 VDC
21.6 - 26.4 VDC
X1-2: Typ 5 mA @ 24 VDC
X3-8: Typ 4 mA @ 24 VDC
X1-2: 6.0 mA @ 26.4 VDC
X3-8: 5.0 mA @ 26.4 VDC
X1-2: 4.7 k @ 24 VDC
X3-8: 6.8 k @ 24 VDC
X1-2: > 19 VDC
X3-8: > 19 VDC
X1-2: < 4 VDC
X3-8: < 7 VDC
X1-2: 4.5 mA
X3-8: 3.5 mA
X1-2: 0.1 mA
X3-8: 0.5 mA
X1-2: Typ 5 s Max 20 s
X3-8: Typ 2 ms Max 10 ms
X1-2: Typ 5 s Max 20 s
X3-8: Typ 3 ms Max 10 ms
Logic Side (8 points, green LED)
2 (4 points/common) Isolated

Maximum Input Current

24VDC

Input Imp edance


+
+

ON Voltage Level
OFF Voltage Level
+

Minimum ON Current

Maximum OFF Current


OFF to ON Response

ON to OFF Response

Status Indicators
Commons

5 - 27VDC

C0-00DD1-D Built-in I/O Specifications - Outputs

5 - 27VDC

24VDC

Equivalent Input Circuit


Internal Module Circuitry

Optical Isolator

INPUT
X1-X4
Typical

C2 COM

Minimum Output Current


Maximum Leakage Current
On Voltage Drop
Maximum Inrush Current

0.2 mA
0.1 mA @ 30.0 VDC
0.5 VDC @ 0.1 A
150 mA for 10 ms
Y1: typ 5 s; max 20 s
Y2-6: < 0.5 ms
Y1: typ 5 s; max 20 s
Y2-6: < 0.5 ms
Logic Side (6 points, red LED)
2 (4 points/com & 2 points/com) Isolated

Current Consumption at 24VDC


Terminal Block Replacement Part No.
Weight

Equivalent Output Circuit


Internal Module Circuitry
24 VDC
+

+V
L

Optical Isolator

OUTPUT
Y1

5 - 27 VDC

5 - 27 VDC

Inputs

0
0
32
Optical Isolator

OUTPUT
Y5-Y6

5 - 27 VDC

ZipLink Pre-Wired PLC


Connection Cables and Modules

Outputs

C3 COM

Points

Optical Isolator

120 mA
C0-16TB
5.0 oz (140 g)

C0-00DD1-D Temperature Derating Chart

High response
circuit

OUTPUT
Y2-Y4

20-28 VDC Maximum @ 60 mA


(All Points On)

General Specifications

C0-00DD1-D
To X6-X8
commons

0.1 A/point; C3: 0.4 A/common,


C4: 0.2 A/common

Status Indicators
Commons
External DC Power
Required

Optical Isolator

INPUT
X5-X8
Typical

24 VDC

Maximum Output Current

ON to OFF Response
To X2-X4
commons

6 (Sink)
5-27 VDC
4-30 VDC

OFF to ON Response

24 VDC
C1 COM

Outputs per Module


Operating Voltage Range
Output Voltage Range

*
C4 COM
Note: C3 & C4 are not internally connected.
* Zener Diode Power Dissipation: 200 mW

10
50

20
68

30
85

40
104

50 55 C
122 131 F

Surrounding Temperature (C/F)


* Use every other input/output.

20-pin connector cable


ZL-RTB20 20-pin feedZL-C0-CBL20 (0.5 m length)
through connector
ZL-C0-CBL20-1 (1.0 m length)
module
ZL-C0-CBL20-2 (2.0 m length)

Volume 13

e1-42

Programmable Controllers

1 - 80 0 - 633 - 0405

Basic CPU Module Specifications


C0-00DD2-D

<--->

Company
Information

C0-00DD2-D Built-in I/O Specifications - Inputs


Inputs per Module
Operating Voltage Range
Input Voltage Range

8 DC Input/6 Sourcing DC Output Micro PLC

8 (Sink/Source)
24 VDC
21.6 - 26.4 VDC
X1-2: Typ 5 mA @ 24 VDC
X3-8: Typ 4 mA @ 24 VDC
X1-2: 6.0 mA @ 26.4 VDC
X3-8: 5.0 mA @ 26.4 VDC
X1-2: 4.7 k @ 24 VDC
X3-8: 6.8 k @ 24 VDC
X1-2: > 19 VDC
X3-8: > 19 VDC
X1-2: < 4 VDC
X3-8: < 7 VDC
X1-2: 4.5 mA
X3-8: 3.5 mA
X1-2: 0.1 mA
X3-8: 0.5 mA
X1-2: Typ 5 s Max 20 s
X3-8: Typ 2 ms Max 10 ms
X1-2: Typ 5 s Max 20 s
X3-8: Typ 3 ms Max 10 ms

Input Current
Maximum Input Current

Wiring Diagram
C0-00DD2-D

Input Impedance

24VDC

C1

ON Voltage Level
+

X1
X2

OFF Voltage Level

X3

Minimum ON Current

X4
C2

Maximum OFF Current


+

X5
X6

X7

OFF to ON Response
ON to OFF Response

X8

Y2

Y3

Y4

V2
Y5

Y6

Status Indicators
Commons

Maximum Inrush Current

Internal Module Circuitry

OFF to ON Response

Optical Isolator

INPUT
X1-X4
Typical

ON to OFF Response
Status Indicators
Commons

24 VDC
C1 COM
To X2-X4
commons

General Specifications

Optical Isolator

INPUT
X5-X8
Typical

Current Consumption at 24VDC


Terminal Block Replacement Part No.
Weight

24 VDC
C2 COM

Equivalent Output Circuit

High response
circuit

Optical Isolator

Points

V1

OUTPUT Y1

ZipLink Pre-Wired PLC


Connection Cables and Modules

*
L

24 VDC
+

20
68

30
85

40
104

50 55 C
122 131 F

C-more &
other HMI
Drives
Soft
Starters
Motors &
Gearbox
Steppers/
Servos
Motor
Controls
Proximity
Sensors
Photo
Sensors
Limit
Switches
Encoders
Current
Sensors
Pressure
Sensors
Temperature
Sensors
Pushbuttons/
Lights
Process
Relays/
Timers
Comm.

Circuit
Protection

Tools

Surrounding Air Temperature (C/F)

Pneumatics
Appendix

OUTPUT Y2-Y4

V2

*
L

Optical Isolator

10
50

Software

Enclosures

0
0
32

Field I/O

Power

Outputs

4
2

Y1

Programmable
Controllers

Terminal
Blocks &
Wiring

Inputs

Internal Module Circuitry

120 mA
C0-16TB
5.0 oz (140 g)

C0-00DD2-D Temperature Derating Chart

To X6-X8
commons

24 VDC
+

6 (Source)
24 VDC
19.2- 30 VDC
0.1 A/point, 0.6 A/common
0.2 mA
0.1 mA @ 30 VDC
Y1: 1.0 VDC @ 0.1 A
Y2-6: 0.5 VDC @ 0.1 A
150 mA for 10 ms
Y1: typ 5 s; max 20 s
Y2-6: < 0.5 ms
Y1: typ 5 s; max 20 s
Y2-6: < 0.5 ms
Logic Side (6 points, red LED)
1 (6 points/common)

On Voltage Drop

Equivalent Input Circuit

1 (6 points/common)

Outputs per Module


Operating Voltage Range
Output Voltage Range
Maximum Output Current
Minimum Output Current
Maximum Leakage Current

24VDC

CO

Logic Side (8 points, green LED)

C0-00DD2-D Built-in I/O Specifications - Outputs

Y1

V1

Systems
Overview

Optical Isolator

OUTPUT Y5-Y6
CO COM

ZL-RTB20 20-pin feedthrough connector


module

20-pin connector cable


ZL-C0-CBL20 (0.5 m length)
ZL-C0-CBL20-1 (1.0 m length)
ZL-C0-CBL20-2 (2.0 m length)

*Zener Diode Power Dissipation: 200 mW

Volume 13

w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c

Programmable Controllers

e1-43

Product
Index
Part #
Index

Basic CPU Module Specifications


C0-00DR-D

<--->

C0-00DR-D Built-in I/O Specifications - Inputs

Inputs per Module


Operating Voltage Range
Input Voltage Range

8 DC Input/6 Relay Output Micro PLC

Input Current
Wiring Diagram
C0-00DR-D

Maximum Input Current


Input Impedance

24VDC

C1

ON Voltage Level

X1
X2

OFF Voltage Level

X3
X4

Minimum ON Current

C2

Maximum OFF Current

X5
X6

X7

OFF to ON Response

X8

ON to OFF Response
C3
Y1

Y2

Y3

Y4

L
L

Y6

Status Indicators
Commons

6-27VDC
6 - 240VAC

Outputs per Module


Operating Voltage Range
Output Voltage Range
Output Type

C0-00DR-D Built-in I/O Specifications - Outputs

C4
Y5

6-27VDC
6 - 240VAC

Maximum Current
Minimum Load Current
Maximum Inrush Current
OFF to ON Response
ON to OFF Response
Status Indicators
Commons

Equivalent Input Circuit


Internal Module Circuitry

Optical Isolator

INPUT
X1-X4
Typical

+
24 VDC

Current Consumption at 24VDC


Terminal Block Replacement Part No.
Weight

To X2-X4
commons

Optical Isolator

INPUT
X5-X8
Typical

C0-00DR-D Temperature Derating Chart

24 VDC

C2 COM

Equivalent Output Circuit


Internal Module Circuitry
OUTPUT
Y1-Y4
Typical

C3

2
0
10
50

20
68

30
85

40
104

30 VDC Resistive
30 VDC Solenoid
250 VAC Resistive
250 VAC Solenoid

50 55 C
122 131 F

Surrounding Air Temperature (C/F)


* Use every other input/output.

COM

C0-16TB
5.6 oz (160 g)

Voltage & Load Type Load Current: 1 A

Outputs

0
32

120 mA

Typical Relay Life (Operations)


at Room Temperature

Inputs

Points

To X6-X8
commons

6-27 VDC
6-240 VAC

6
6-240 VAC (47-63 Hz), 6-27 VDC
5-264 VAC (47-63 Hz), 5-30 VDC
Relay, form A (SPST)
1 A/point; C3: 4 A/common,
C4: 2 A/common
5 mA @ 5 VDC
3 A for 10 ms
< 15 ms
< 15 ms
Logic Side (6 points, red LED)
2 (4 points/com & 2 points/com) Isolated

General Specifications

C1 COM

8 (Sink/Source)
24 VDC
21.6-26.4VDC
X1-2: Typ 5 mA @ 24 VDC
X3-8: Typ 4 mA @ 24 VDC
X1-2: 6.0 mA @ 26.4 VDC
X3-8: 5.0 mA @ 26.4 VDC
X1-2: 4.7 k @ 24 VDC
X3-8: 6.8 k @ 24 VDC
X1-2: > 19 VDC
X3-8: > 19 VDC
X1-2: < 4 VDC
X3-8: < 7 VDC
X1-2: 4.5 mA
X3-8: 3.5 mA
X1-2: 0.1 mA
X3-8: 0.5 mA
X1-2: Typ 5 s Max 20 s
X3-8: Typ 2 ms Max 10 ms
X1-2: Typ 5 s Max 20 s
X3-8: Typ 3 ms Max 10 ms
Logic Side (8 points, green LED)
2 (4 points/common) Isolated

300,000 cycles
50,000 cycles
500,000 cycles
200,000 cycles

ON to OFF = 1 cycle

ZipLink Pre-Wired PLC


Connection Cables and Modules

To Y2-Y4
commons

6-27 VDC
6-240 VAC

OUTPUT
Y5-Y6
Typical

C4

COM
To Y6
common

* Varistor Joule Rating: 20 J

ZL-RTB20 20-pin feedthrough connector module

20-pin connector cable


ZL-C0-CBL20 (0.5 m length)
ZL-C0-CBL20-1 (1.0 m length)
ZL-C0-CBL20-2 (2.0 m length)

Volume 13

e1-44

Programmable Controllers

1 - 80 0 - 633 - 0405

Basic CPU Module Specifications


C0-00AR-D

<--->

C0-00AR-D Built-in I/O Specifications - Inputs

Wiring Diagram
C0-00AR-D
X1
X2
X3
X4
C2
X5
X6
X7
X8
C3
Y1

Y2

Y3

Y4

6-27VDC
6 - 240VAC

Y5

Y6

Equivalent Input Circuit


Internal Module Circuitry

C1

Optical Isolator

X5-X8
Typical

COM

Output Voltage Range

5-264 VAC (47-63 Hz)


5-30 VDC

Output Type

Relay, form A (SPDT)

Maximum Current

1 A/point; C3: 4 A/common,


C4: 2 A/common

Minimum Load Current


Maximum Inrush Current
OFF to ON Response
ON to OFF Response
Status Indicators
Commons

5 mA @ 5 VDC
3 A for 10 ms
< 15 ms
< 15 ms
Logic Side (6 points, red LED)
2 (4 points/com & 2 points/com) Isolated

Points

Equivalent Output Circuit


Internal Module Circuitry
OUTPUT
Y1-Y4
Typical

2
0
10
50

20
68

30
85

C0-16TB
5.6 oz (160 g)

Voltage & Load Type Load Current: 1 A

Outputs

0
32

120 mA

Typical Relay Life (Operations)


at Room Temperature

Inputs

6
To X6-X8
commons

C3

6
6-240 VAC (47-63 Hz), 6-27 VDC

C0-00AR-D Temperature Derating Chart


8

Outputs per Module


Operating Voltage Range

Current Consumption at 24VDC


Terminal Block Replacement Part No.
Weight

COM

6-27 VDC
6-240 VAC

> 60 VAC
< 20 VAC
5 mA
2 mA
< 40 ms
< 40 ms
Logic Side (8 points, green LED)
2 (4 points/common) Isolated

General Specifications

INPUT

C2

ON Voltage Level
OFF Voltage Level
Minimum ON Current
Maximum OFF Current
OFF to ON Response
ON to OFF Response
Status Indicators
Commons

Optical Isolator

X1-X4
Typical

To X2-X4
commons

100-120 VAC

Input Impedance

15 k @ 50 Hz
12 k @ 60 Hz

C0-00AR-D Built-in I/O Specifications - Outputs

6-27VDC
6 - 240VAC

C4

Maximum Input Current

8
100-120 VAC
80-144 VAC
47-63 Hz
8.5 mA @ 100 VAC at 50 Hz
10 mA @ 100 VAC at 60 Hz
16 mA @ 144 VAC at 55C or 131F

Input Current

100 - 120VAC

C1

100-120 VAC

Systems
Overview

Inputs per Module


Operating Voltage Range
Input Voltage Range
AC Frequency

8 AC Input/6 Relay Output Micro PLC

INPUT

Company
Information

40
104

30 VDC Resistive
30 VDC Solenoid
250 VAC Resistive
250 VAC Solenoid

ON to OFF = 1 cycle

50 55 C
122 131 F

Surrounding Air Temperature (C/F)


* Use every other output.

300,000 cycles
50,000 cycles
500,000 cycles
200,000 cycles

ZipLink Pre-Wired PLC


Connection Cables and Modules

COM

Programmable
Controllers
Field I/O
Software
C-more &
other HMI
Drives
Soft
Starters
Motors &
Gearbox
Steppers/
Servos
Motor
Controls
Proximity
Sensors
Photo
Sensors
Limit
Switches
Encoders
Current
Sensors
Pressure
Sensors
Temperature
Sensors
Pushbuttons/
Lights
Process
Relays/
Timers
Comm.
Terminal
Blocks &
Wiring
Power
Circuit
Protection
Enclosures
Tools

To Y2-Y4
commons

Pneumatics

6-27 VDC
6-240 VAC

OUTPUT
Y5-Y6
Typical

C4

Appendix
Product
Index

COM
To Y6
common

* Varistor Joule Rating: 20 J

ZL-RTB20 20-pin feedthrough connector


module

20-pin connector cable


ZL-C0-CBL20 (0.5 m length)
ZL-C0-CBL20-1 (1.0 m length)
ZL-C0-CBL20-2 (2.0 m length)
Volume 13

w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c

Programmable Controllers

e1-45

Part #
Index

Standard CPU Module Specifications


C0-01DD1-D

<--->

C0-01DD1-D Built-in I/O Specifications - Inputs


Inputs per Module
Operating Voltage Range
Input Voltage Range

8 DC Input/6 Sinking DC Output Micro PLC

Input Current

Wiring Diagram
C0-01DD1-D

8 (Sink/Source)
24 VDC
21.6 - 26.4 VDC
X1-2: Typ 5 mA @ 24 VDC
X3-8: Typ 4 mA @ 24 VDC
X1-2: 6.0 mA @ 26.4 VDC
X3-8: 5.0 mA @ 26.4 VDC
X1-2: 4.7 k @ 24 VDC
X3-8: 6.8 k @ 24 VDC
X1-2: > 19 VDC
X3-8: > 19 VDC
X1-2: < 4 VDC
X3-8: < 7 VDC
X1-2: 4.5 mA
X3-8: 3.5 mA
X1-2: 0.1 mA
X3-8: 0.5 mA
X1-2: Typ 5 s Max 20 s
X3-8: Typ 2 ms Max 10 ms
X1-2: Typ 5 s Max 20 s
X3-8: Typ 3 ms Max 10 ms
Logic Side (8 points, green LED)
2 (4 points/common) Isolated

Maximum Input Current

24VDC

Input Impedance

ON Voltage Level

PWR

OFF Voltage Level

RUN

ERR

Minimum ON Current

PORT1

Maximum OFF Current

TX1
RX1

RX2

PORT2

ON to OFF Response
5 - 27VDC

Status Indicators
Commons

RS-485

PORT3

OFF to ON Response
+

TX2

5 - 27VDC

C0-01DD1-D Built-in I/O Specifications - Outputs

24VDC

RX3

TX3

NOTE: When using Standard CPUs, you must use CLICK


programming software version V1.20 or later.
Equivalent Input Circuit
Internal Module Circuitry

Optical Isolator

INPUT
X1-X4
Typical

6 (Sink)
5-27 VDC
4-30 VDC

Maximum Output Current

0.1 A/point; C3: 0.4 A/common, C4: 0.2


A/common

Minimum Output Current


Maximum Leakage Current
On Voltage Drop
Maximum Inrush Current

0.2 mA
0.1 mA @ 30.0 VDC
0.5 VDC @ 0.1 A
150 mA for 10 ms
Y1: typ 5 s; max 20 s
Y2-6: < 0.5 ms
Y1: typ 5 s; max 20 s
Y2-6: < 0.5 ms
Logic Side (6 points, red LED)
2 (4 points/com & 2 points/com)

OFF to ON Response
ON to OFF Response

24 VDC
C1 COM

Status Indicators
Commons
External DC Power
Required

To X2-X4
commons

Optical Isolator

INPUT
X5-X8
Typical

+
+

Outputs per Module


Operating Voltage Range
Output Voltage Range

24 VDC

20-28 VDC Maximum @ 60 mA


(All Points On)

General Specifications
C2 COM

Current Consumption at 24VDC


Terminal Block Replacement Part No.
Weight

To C0-01DD1-D
X6-X8

commons

Equivalent Output Circuit


Internal Module Circuitry
24 VDC

+V

OUTPUT
Y1

5 - 27 VDC

C0-01DD1-D Temperature Derating Chart

Optical Isolator

8
High response
circuit

Optical Isolator

OUTPUT
Y2-Y4

5 - 27 VDC

0
32
Optical Isolator

OUTPUT
Y5-Y6

5 - 27 VDC

Outputs

ZL-RTB20 20-pin
feed-through
connector module

*
C3 COM

ZipLink Pre-Wired PLC


Connection Cables and Modules

Inputs

Points

140 mA
C0-16TB
5.0 oz (140 g)

*
C4 COM
Note: C3 & C4 are not internally connected.

10
50

20
68

30
85

40
104

50 55 C
122 131 F

Surrounding Temperature (C/F)


* Use every other input/output.

20-pin connector cable


ZL-C0-CBL20 (0.5 m length)
ZL-C0-CBL20-1 (1.0 m length)
ZL-C0-CBL20-2 (2.0 m length)

* Zener Diode Power Dissipation: 200 mW

Volume 13

e1-46

Programmable Controllers

1 - 80 0 - 633 - 0405

Standard CPU Module Specifications


C0-01DD2-D

<--->

C0-01DD2-D Built-in I/O Specifications - Inputs


Inputs per Module
Operating Voltage Range
Input Voltage Range

8 DC Input/6 Sourcing DC Output Micro PLC


C0-01DD2-D

X2

ERR

X5

OFF Voltage Level

X6
X8

RX1

V1

TX2
RX2
PORT2
RS-485

PORT3

OFF to ON Response

Y1

Y2

Y3

Y4

V2

TX3

Y5

RX3

Y6

ON to OFF Response
+

TX1

Maximum OFF Current

Status Indicators
Commons

24VDC

Outputs per Module


Operating Voltage Range
Output Voltage Range
Maximum Output Current
Minimum Output Current
Maximum Leakage Current

NOTE: When using Standard CPUs, you must use CLICK


programming software version V1.20 or later.

On Voltage Drop

Equivalent Input Circuit

Maximum Inrush Current

Internal Module Circuitry

+
+

2 (4 points/common) Isolated

C0-01DD2-D Built-in I/O Specifications - Outputs

CO

OFF to ON Response

Optical Isolator

INPUT
X1-X4
Typical

Logic Side (8 points, green LED)

X7

PORT1

Minimum ON Current

C2

ON Voltage Level

X3
X4

Input Impedance

X1

RUN

Maximum Input Current

24VDC

C1

8 (Sink/Source)
24 VDC
21.6 - 26.4 VDC
X1-2: Typ 5 mA @ 24 VDC
X3-8: Typ 4 mA @ 24 VDC
X1-2: 6.0 mA @ 26.4 VDC
X3-8: 5.0 mA @ 26.4 VDC
X1-2: 4.7 k @ 24 VDC
X3-8: 6.8 k @ 24 VDC
X1-2: > 19 VDC
X3-8: > 19 VDC
X1-2: < 4 VDC
X3-8: < 7 VDC
X1-2: 4.5 mA
X3-8: 3.5 mA
X1-2: 0.1 mA
X3-8: 0.5 mA
X1-2: Typ 5 s Max 20 s
X3-8: Typ 2 ms Max 10 ms
X1-2: Typ 5 s Max 20 s
X3-8: Typ 3 ms Max 10 ms

Input Current

Wiring Diagram

PWR

Company
Information

ON to OFF Response
Status Indicators
Commons

24 VDC

6 (Source)
24 VDC
19.2-30 VDC
0.1 A/point , 0.6 A/common
0.2 mA
0.1 mA @ 30 VDC
Y1: 1.0 VDC @ 0.1 A
Y2-6: 0.5 VDC @ 0.1 A
150 mA for 10 ms
Y1: typ 5 s; max 20 s
Y2-6: < 0.5 ms
Y1: typ 5 s; max 20 s
Y2-6: < 0.5 ms
Logic Side (6 points, red LED)
1 (6 points/common)

General Specifications

+
+

Current Consumption at 24VDC


Terminal Block Replacement Part No.
Weight

Optical Isolator

INPUT
X5-X8
Typical

24 VDC
C2 COM

Equivalent Output Circuit

*
L

High response
circuit

Optical Isolator

Y1
OUTPUT Y1

24 VDC
+

OUTPUT Y2-Y4

Drives
Soft
Starters
Motors &
Gearbox
Steppers/
Servos
Motor
Controls
Proximity
Sensors
Photo
Sensors
Limit
Switches
Encoders
Current
Sensors
Pressure
Sensors
Temperature
Sensors
Pushbuttons/
Lights

Relays/
Timers
Comm.
Terminal
Blocks &
Wiring

Tools

0
32

10
50

20
68

30
85

40
104

Pneumatics

50 55 C
122 131 F

Appendix

Surrounding Air Temperature (C/F)

V2

*
L

Optical Isolator

C-more &
other HMI

Enclosures

2
0

Software

Circuit
Protection

ZL-RTB20 20-pin
feed-through
connector module

Outputs

Field I/O

Power

Inputs

V1

Points

24 VDC
+

Internal Module Circuitry

140 mA
C0-16TB
5.0 oz (140 g)

ZipLink Pre-Wired PLC


Connection Cables and Modules

C0-01DD2-D Temperature Derating Chart

To X6-X8
commons

Programmable
Controllers

Process

C1 COM
To X2-X4
commons

Systems
Overview

Optical Isolator

OUTPUT Y5-Y6
CO COM

20-pin connector cable


ZL-C0-CBL20 (0.5 m length)
ZL-C0-CBL20-1 (1.0 m length)
ZL-C0-CBL20-2 (2.0 m length)

*Zener Diode Power Dissipation: 200 mW

Volume 13

w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c

Programmable Controllers

e1-47

Product
Index
Part #
Index

Standard CPU Module Specifications


C0-01DR-D

<--->

C0-01DR-D Built-in I/O Specifications - Inputs


Inputs per Module
Operating Voltage Range
Input Voltage Range

8 DC Input/6 Relay Output Micro PLC

Input Current
Maximum Input Current

Wiring Diagram
C0-01DR-D

24VDC

C1
X2

C2

ERR

X5

OFF Voltage Level

X6
X7
X8

Maximum OFF Current

PORT1
TX1

Minimum ON Current

X4

RUN

ON Voltage Level

X3
PWR

Input Impedance

X1

RX1

OFF to ON Response
C3

TX2
RX2
PORT2
RS-485

PORT3

Y1

Y2

Y3

Y4

6-27VDC
6 - 240VAC

Y5

RX3

Y6

Status Indicators
Commons

6-27VDC
6 - 240VAC

C4

TX3

ON to OFF Response

C0-01DR-D Built-in I/O Specifications - Outputs

NOTE: When using Standard CPUs, you must use CLICK


programming software version V1.20 or later.
Equivalent Input Circuit
Internal Module Circuitry

Optical Isolator

INPUT
X1-X4
Typical

Outputs per Module


Operating Voltage Range
Output Voltage Range
Output Type

6
6-240 VAC (47-63 Hz), 6-27 VDC
5-264 VAC (47-63 Hz), 5-30 VDC
Relay, form A (SPST)

Maximum Current

1 A/point; C3: 4 A/common,


C4: 2 A/common

Minimum Load Current


Maximum Inrush Current
OFF to ON Response
ON to OFF Response
Status Indicators

5 mA @ 5 VDC
3 A for 10 ms
< 15 ms
< 15 ms
Logic Side (6 points, red LED)
2 (4 points/com &
2 points/com) Isolated

Commons

24 VDC

General Specifications

C1 COM

Current Consumption at 24VDC


Terminal Block Replacement Part No.
Weight

To X2-X4
commons

Optical Isolator

INPUT
X5-X8
Typical

+
+

8 (Sink/Source)
24 VDC
21.6-26.4 VDC
X1-2: Typ 5 mA @ 24 VDC
X3-8: Typ 4 mA @ 24 VDC
X1-2: 6.0 mA @ 26.4 VDC
X3-8: 5.0 mA @ 26.4 VDC
X1-2: 4.7 k @ 24 VDC
X3-8: 6.8 k @ 24 VDC
X1-2: > 19 VDC
X3-8: > 19 VDC
X1-2: < 4 VDC
X3-8: < 7 VDC
X1-2: 4.5 mA
X3-8: 3.5 mA
X1-2: 0.1 mA
X3-8: 0.5 mA
X1-2: Typ 5 s Max 20 s
X3-8: Typ 2 ms Max 10 ms
X1-2: Typ 5 s Max 20 s
X3-8: Typ 3 ms Max 10 ms
Logic Side (8 points, green LED)
2 (4 points/common) Isolated

24 VDC

Typical Relay Life (Operations)


at Room Temperature

C0-01DR-D Temperature Derating Chart


C2 COM

8
To X6-X8
commons

Internal Module Circuitry

6-27 VDC
6-240 VAC

OUTPUT
Y1-Y4
Typical

C3

Points

Equivalent Output Circuit

*
10
50

20
68

30
85

OUTPUT
Y5-Y6
Typical
C4

40
104

50 55 C
122 131 F

Surrounding Air Temperature (C/F)


* Use every other input/output.

300,000 cycles
50,000 cycles
500,000 cycles
200,000 cycles

ON to OFF = 1 cycle

0
0
32

COM

30 VDC Resistive
30 VDC Solenoid
250 VAC Resistive
250 VAC Solenoid

Outputs

To Y2-Y4
commons

6-27 VDC
6-240 VAC

Voltage & Load Type Load Current: 1 A

Inputs

140 mA
C0-16TB
5.6 oz (160 g)

ZipLink Pre-Wired PLC Connection


Cables and Modules for CLICK PLC

COM
To Y6
common

ZL-RTB20
20-pin feed-through
connector module

20-pin connector cable


ZL-C0-CBL20 (0.5 m length)
ZL-C0-CBL20-1 (1.0 m length)
ZL-C0-CBL20-2 (2.0 m length)

* Varistor Joule Rating: 20 J

Volume 13

e1-48

Programmable Controllers

1 - 80 0 - 633 - 0405

Standard CPU Module Specifications


C0-01AR-D Built-in I/O Specifications - Inputs

C0-01AR-D <--->

Inputs per Module


Operating Voltage Range
Input Voltage Range
AC Frequency

8 AC Input/6 Relay Output Micro PLC


C0-01AR-D

100 - 120VAC

C1
X1
X2
X3
X4

PWR
RUN

C2

ERR

X5
X6

PORT1

X7

TX1

X8

RX1

C3
TX2
RX2
PORT2
RS-485

Y1

Y2

Y3

Y4

C4

TX3

Y5

RX3

Y6

6-27VDC
6 - 240VAC

6-27VDC
6 - 240VAC

Equivalent Input Circuit


Internal Module Circuitry

100-120 VAC

C1

Input Impedance

15 k @ 50 Hz
12 k @ 60 Hz

ON Voltage Level
OFF Voltage Level
Minimum ON Current
Maximum OFF Current
OFF to ON Response
ON to OFF Response
Status Indicators
Commons

> 60 VAC
< 20 VAC
5 mA
2 mA
< 40 ms
< 40 ms
Logic Side (8 points, green LED)
2 (4 points/common) Isolated

C0-01AR-D Built-in I/O Specifications - Outputs

NOTE: When using Standard CPUs, you must use CLICK


programming software version V1.20 or later.

INPUT

Maximum Input Current

8
100-120 VAC
80-144 VAC
47-63 Hz
8.5 mA @ 100 VAC at 50 Hz
10 mA @ 100 VAC at 60 Hz
16 mA @ 144 VAC

Input Current
Wiring Diagram

PORT3

Outputs per Module


Operating Voltage Range
Output Voltage Range
Output Type

6
6-240 VAC (47-63 Hz), 6-27 VDC
5-264 VAC (47-63 Hz), 5-30 VDC
Relay, form A (SPST)

Maximum Current

1 A/point;
C3: 4A/common, C4: 2A/common

Minimum Load Current


Maximum Inrush Current
OFF to ON Response
ON to OFF Response
Status Indicators

5 mA @ 5 VDC
3 A for 10 ms
< 15 ms
< 15 ms
Logic Side (6 points, red LED)
2 (4 points/com &
2 points/com) Isolated

Commons

Optical Isolator

X1-X4
Typical

Current Consumption at 24VDC


Terminal Block Replacement Part No.
Weight

COM

C0-01AR-D Temperature Derating Chart

INPUT

Optical Isolator

X5-X8
Typical

Points

6
C2

COM
To X6-X8
commons

Internal Module Circuitry

6-27 VDC
6-240 VAC

OUTPUT
Y1-Y4
Typical

C3

Voltage & Load Type Load Current: 1 A

Outputs

30 VDC Resistive
30 VDC Solenoid
250 VAC Resistive
250 VAC Solenoid

Equivalent Output Circuit

0
0
32

10
50

20
68

30
85

140 mA
C0-16TB
5.6 oz (160 g)

Typical Relay Life (Operations)


at Room Temperature

Inputs

40
104

50 55 C
122 131 F

300,000 cycles
50,000 cycles
500,000 cycles
200,000 cycles

ON to OFF = 1 cycle

C4

COM
To Y6
common

Software
C-more &
other HMI
Drives
Soft
Starters
Motors &
Gearbox
Steppers/
Servos
Motor
Controls
Proximity
Sensors
Photo
Sensors
Limit
Switches
Encoders
Current
Sensors
Pressure
Sensors

Pushbuttons/
Lights
Process
Relays/
Timers
Comm.
Terminal
Blocks &
Wiring
Power

Tools

ZipLink Pre-Wired PLC Connection


Cables and Modules for CLICK PLC
L

Field I/O

Enclosures

COM

OUTPUT
Y5-Y6
Typical

Programmable
Controllers

Circuit
Protection

Surrounding Air Temperature (C/F)


* Use every other output.

To Y2-Y4
commons

6-27 VDC
6-240 VAC

Systems
Overview

Temperature
Sensors

General Specifications

To X2-X4
commons

100-120 VAC

Company
Information

ZL-RTB20
20-pin feed-through
connector module

20-pin connector cable


ZL-C0-CBL20 (0.5 m length)
ZL-C0-CBL20-1 (1.0 m length)
ZL-C0-CBL20-2 (2.0 m length)

* Varistor Joule Rating: 20 J

Volume 13

w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c

Programmable Controllers

e1-49

Pneumatics
Appendix
Product
Index
Part #
Index

Analog CPU Module Specifications

C0-02DD1-D

<--->

4 DC Input/4 Sinking DC Output; 2 Analog In/2 Analog Out Micro PLC


General Specifications
Wiring Diagram
C0-02DD1-D

140 mA
Current Consumption at 24VDC
Terminal Block Replacement Part No. C0-16TB
5.3 oz (150 g)
Weight

24VDC

C1
X1

X2

See Discrete I/O


Specifications - Inputs
(X1 through X4)

X3
C2

ERR

Y1

Y2

PORT1

Y3

TX1

Y4

RX1

+V

5 - 27
VDC

24
VDC

AD1V

Transmitter 0-5V

TX2

AD1 I

Transmitter 4-20mA

RX2

AD2V

Transmitter 0-5V

AD2 I

Transmitter 4-20mA

PORT2

PORT3

NOTE: WHEN USING


ANALOG CPUS, YOU MUST
USE CLICK PROGRAMMING SOFTWARE VERSION

See Discrete I/O


Specifications - Outputs
(Y1 through Y4)

RUN

PWR

X4

V1.12 OR LATER.

See Analog
Specifications - Voltage
& Current Input
(AD1V through AD2I)

ACOM

RS-485

DA1V

TX3

DA1 I

RX3

DA2V

See Analog Specifications Voltage & Current Output


(DA1V through DA2I)
+

DA2 I

Transmitter
P/S

IMPORTANT: YOU CAN USE ONLY ONE TERMINAL (VOLTAGE


YOU MUST ALSO SELECT THE
ANALOG TYPE (VOLTAGE OR CURRENT) IN THE CPU BUILT-IN
I/O SETUP IN THE CLICK PROGRAMMING SOFTWARE
(PULL-DOWN MENU SETUP > CPU BUILT-IN I/O SETUP).
OR CURRENT) PER CHANNEL.

X1 - X4
C0-02DD1-D Discrete I/O Specifications - Inputs

Equivalent Discrete Input Circuit

4 (Sink/Source)
Inputs per Module
Operating Voltage Range 24 VDC
21.6 - 26.4 VDC
Input Voltage Range

Maximum Input Current


Input Impedance
ON Voltage Level
OFF Voltage Level
Minimum ON Current
Maximum OFF Current
OFF to ON Response
ON to OFF Response
Status Indicators
Commons

* Threshold level is 70% amplitude.

Optical Isolator
Input
X1-X2

+
+

To high
response
circuit

24
VDC
Optical Isolator

Input
X3-X4

24
VDC

COM
C1

C0-02DD1-D Temperature Derating Chart


4
Inputs

Points

Input Current

X1-2: Typ 5 mA @ 24 VDC


X3-4: Typ 4 mA @ 24 VDC
X1-2: 6.0 mA @ 26.4 VDC
X3-4: 5.0 mA @ 26.4 VDC
X1-2: 4.7 k @ 24 VDC
X3-4: 6.8 k @ 24 VDC
X1-2: > 19 VDC
X3-4: > 19 VDC
X1-2: < 4 VDC
X3-4: < 7 VDC
X1-2: 4.5 mA
X3-4: 3.5 mA
X1-2: 0.1 mA
X3-4: 0.5 mA
X1-2: Typ 5 s Max 20 s*
X3-4: Typ 2 ms Max 10 ms
X1-2: Typ 5 s Max 20 s*
X3-4: Typ 3 ms Max 10 ms
Logic Side (4 points, green LED)
1 (4 points/common)

Internal Module Circuitry

There are no ZipLink prewired PLC connection cables


and modules for the analog
CPUs (cannot mix discrete
I/O and analog I/O signals in
a ZIPLink cable).

2
1
0
0
32

10
50

20
68

30
85

40
104

50 55 C
122 131 F

Surrounding Air Temperature (C/F)

Volume 13

e1-50

Programmable Controllers

1 - 80 0 - 633 - 0405

Analog CPU Module Specifications


C0-02DD1-D (contd)

Company
Information
Systems
Overview

Equivalent Discrete Output Circuit

Y1 - Y4

24 VDC
+

Programmable
Controllers

Internal Module Circuitry

+V

Optical Isolator
+

C0-02DD1-D Discrete I/O Specifications - Outputs


4 (Sink)
5-27 VDC
4-30 VDC
0.1 A/point; 0.4 A/common
0.2 mA
0.1 mA @ 30.0 VDC
0.5 VDC @ 0.1 A
150 mA for 10 ms
Y1: typ 5 s; max 20 s; Y2-4: < 0.5 ms
Y1: typ 5 s; max 20 s; Y2-4: < 0.5 ms
Logic Side (4 points, red LED)
1 (4 points/common)
20-28 VDC Maximum @ 60 mA (all points on)

C-more &
other HMI

+V
Optical Isolator

OUTPUT
Y2-Y4

Drives

5-27
VDC

COM
C2

Soft
Starters

* Zener Diode Power Dissipation: 200 mW

Motors &
Gearbox

C0-02DD1-D Temperature Derating Chart


4
Outputs

Steppers/
Servos

2
1

AD1V - AD2I

0
0
32

C0-02DD1-D Analog Specifications - Voltage Input


Number of Channels
Input Range
Resolution
Conversion Time
Input Impedance
Input Stability
Full-Scale Calibration Error
Offset Calibration Error
Accuracy vs. Temperature Error

2 (voltage/current selectable)
0 - 5 VDC (6 VDC Max.)
12 bit
50 ms
150 k
2 LSB maximum
1.2% maximum
5 mV maximum
100 ppm / C maximum

Analog Voltage Input

10
50

30
85

40
104

50 55 C
122 131 F

C0-02DD1-D Analog Specifications - Current Input


Inputs per Module
Input Range
Resolution
Conversion Time
Input Impedance
Input Stability
Full-Scale Calibration Error
Offset Calibration Error
Accuracy vs. Temperature Error

2 (voltage/current selectable)
4 - 20 mA (sink)
12 bit
50 ms
200
2 LSB
1% maximum
0.1 mA maximum
100 ppm / C maximum

A/D
Converter

Pressure
Sensors
Temperature
Sensors
Pushbuttons/
Lights

A/D
Converter

ACOM
200

Process

+
Transmitter
P/S

Transmitter
P/S

C0-02DD1-D Analog Specifications - Current Output

DA1V - DA2I
C0-02DD1-D Analog Specifications - Voltage Output
Outputs per Module
Output Range
Resolution
Conversion Time
Load Impedance
Full-Scale Calibration Error
Offset Calibration Error
Accuracy vs. Temperature Error

2 (voltage/current selectable)
0 - 5 VDC
12 bit
1 ms
2 k minimum (output current 2.5 mA maximum)
0.8% maximum
5 mV maximum
100 ppm / C maximum

Outputs per Module


Output Range
Resolution
Conversion Time
Loop Supply Voltage

2 (voltage/current selectable)
4 - 20 mA (sink)
12 bit
1 ms
DC 18 - 30 V
250 ohms
Load Power Supply:
DC 18V: 600 maximum
DC 24V: 900 maximum
DC 30V: 1200 maximum

Load Impedance
Full-Scale Calibration Error
Offset Calibration Error
Accuracy vs. Temperature Error

1% maximum
0.1 mA maximum
100 ppm / C maximum

Analog Current Output Circuit


Analog Voltage Output Circuit
Internal Module Circuitry

Load
2k minimum

ACOM

D/A
Converter

Load
250
typical

Volume 13

Programmable Controllers

Terminal
Blocks &
Wiring
Power
Circuit
Protection
Enclosures
Tools
Pneumatics

Part #
Index

100

Transmitter P/S
18-30VDC

w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c

Comm.

Product
Index

D/A
Converter

ACOM

Relays/
Timers

Appendix

Internal Module Circuitry


DAxI

DAxV

Photo
Sensors

Current
Sensors

ADxI

150k

Proximity
Sensors

Encoders

Internal Module Circuitry

Current
Transmitter

Motor
Controls

Limit
Switches

Analog Current Input Circuit

ADxV
ACOM

20
68

Surrounding Air Temperature (C/F)

Internal Module Circuitry

Voltage
Transmitter

Field I/O

High response
circuit

Software

24 VDC
+

Points

Outputs per Module


Operating Voltage Range
Output Voltage Range
Maximum Output Current
Minimum Output Current
Maximum Leakage Current
On Voltage Drop
Maximum Inrush Current
OFF to ON Response
ON to OFF Response
Status Indicators
Commons
External DC Power Required

OUTPUT
Y1

5-27
VDC

e1-51

Analog CPU Module Specifications


C0-02DD2-D

<--->

4 DC Input/4 Sourcing DC Output; 2 Analog In/2 Analog Out Micro PLC


General Specifications
Wiring Diagram

C0-02DD2-D

140 mA
Current Consumption at 24VDC
Terminal Block Replacement Part No. C0-16TB
5.3 oz (150 g)
Weight

24VDC

C1
X1

X2

X3
PWR

X4

RUN

V1

ERR

Y1

Y2

PORT1

Y3

Y4

RX1

C0

24
VDC

VERSION

See Discrete I/O


Specifications - Outputs
(Y1 through Y4)

AD1V

Transmitter 0-5V

TX2

AD1 I

Transmitter 4-20mA

RX2

AD2V

Transmitter 0-5V

AD2 I

Transmitter 4-20mA

PORT3

NOTE: WHEN USING


ANALOG CPUS, YOU
MUST USE CLICK PROGRAMMING SOFTWARE

TX1

PORT2

See Discrete I/O


Specifications - Inputs
(X1 through X4)

V1.12 OR LATER.

See Analog
Specifications - Voltage
& Current Input
(AD1V through AD2I)

ACOM

RS-485

DA1V

TX3

DA1 I

RX3

DA2V

See Analog Specifications Voltage & Current Output


(DA1V through DA2I)

DA2 I

Transmitter
P/S

IMPORTANT: YOU CAN USE ONLY ONE TERMINAL (VOLTAGE


OR CURRENT) PER CHANNEL. YOU MUST ALSO SELECT THE
ANALOG TYPE (VOLTAGE OR CURRENT) IN THE CPU BUILT-IN
I/O SETUP IN THE CLICK PROGRAMMING SOFTWARE
(PULL-DOWN MENU SETUP > CPU BUILT-IN I/O SETUP).

X1 - X4
C0-02DD2-D Discrete I/O Specifications - Inputs

Input Current
Maximum Input Current
Input Impedance
ON Voltage Level
OFF Voltage Level
Minimum ON Current
Maximum OFF Current
OFF to ON Response
ON to OFF Response
Status Indicators
Commons

4 (Sink/Source)
24 VDC
21.6 - 26.4 VDC
X1-2: Typ 5 mA @ 24 VDC
X3-4: Typ 4 mA @ 24 VDC
X1-2: 6.0 mA @ 26.4 VDC
X3-4: 5.0 mA @ 26.4 VDC
X1-2: 4.7 k @ 24 VDC
X3-4: 6.8 k @ 24 VDC
X1-2: > 19 VDC
X3-4: > 19 VDC
X1-2: < 4 VDC
X3-4: < 7 VDC
X1-2: 4.5 mA
X3-4: 3.5 mA
X1-2: 0.1 mA
X3-4: 0.5 mA
X1-2: Typ 5 s Max 20 s*
X3-4: Typ 2 ms Max 10 ms
X1-2: Typ 5 s Max 20 s*
X3-4: Typ 3 ms Max 10 ms
Logic Side (4 points, green LED)
1 (4 points/common)

* Threshold level is 70% amplitude.

Equivalent Discrete Input Circuit


Internal Module Circuitry
Optical Isolator
Input
X1-X2

+
+

To high
response
circuit

24
VDC
Optical Isolator

Input
X3-X4

24
VDC

COM
C1

C0-02DD2-D Temperature Derating Chart


4
Inputs

Points

Inputs per Module


Operating Voltage Range
Input Voltage Range

There are no ZipLink prewired PLC connection


cables and modules for the
analog CPUs (cannot mix
discrete I/O and analog I/O
signals in a ZIPLink cable).

2
1
0
0
32

10
50

20
68

30
85

40
104

50 55 C
122 131 F

Surrounding Air Temperature (C/F)

Volume 13

e1-52

Programmable Controllers

1 - 80 0 - 633 - 0405

Analog CPU Module Specifications


C0-02DD2-D (contd)

Internal Module Circuitry


24 VDC
+

C0-02DD2-D Discrete I/O Specifications - Outputs

High response
circuit

OUTPUT
Y1

Field I/O

C-more &
other HMI

Optical Isolator

*
OUTPUT
Y2-Y4

Drives

COM
C0

Soft
Starters

* Zener Diode Power Dissipation: 200 mW

Motors &
Gearbox

C0-02DD2-D Temperature Derating Chart


4
Outputs

Points

Steppers/
Servos

Motor
Controls

1
0

Number of Channels
Input Range
Resolution
Conversion Time
Input Impedance
Input Stability
Full-Scale Calibration Error
Offset Calibration Error
Accuracy vs. Temperature Error

2 (voltage/current selectable)
0 - 5 VDC (6 VDC Max.)
12 bit
50 ms
150 k
2 LSB maximum
1.2% maximum
5 mV maximum
100 ppm / C maximum

Analog Voltage Input Circuit

0
32

10
50

50 55 C
122 131 F

2 (voltage/current selectable)
4 - 20 mA (sink)
12 bit
50 ms
200 
2 LSB
1% maximum
0.1 mA maximum
100 ppm / C maximum

A/D
Converter

+
Transmitter
P/S

DA1V - DA2I

C0-02DD2-D Analog Specifications - Current Output

C0-02DD2-D Analog Specifications - Voltage Output


Outputs per Module
Output Range
Resolution
Conversion Time
Load Impedance
Full-Scale Calibration Error
Offset Calibration Error
Accuracy vs. Temperature
Error

2 (voltage/current selectable)
0 - 5 VDC
12 bit
1 ms
2 k minimum (output current 2.5
mA maximum)
0.8% maximum
5 mV maximum
100 ppm / C maximum

Outputs per Module


Output Range
Resolution
Conversion Time
Loop Supply Voltage
Load Impedance
Full-Scale Calibration Error
Offset Calibration Error
Accuracy vs. Temperature Error

100 ppm / C maximum

Internal Module Circuitry

Internal Module Circuitry

DAxI

DAxV
ACOM

2 (voltage/current selectable)
4 - 20 mA (sink)
12 bit
1 ms
DC 18 - 30 V
250
Load Power Supply:
DC 18V: 600 maximum
DC 24V: 900 maximum
DC 30V: 1200 maximum
1% maximum
0.1 mA maximum

Analog Current Output Circuit

Analog Voltage Output Circuit

D/A
Converter

Load
250
typical

D/A
Converter

ACOM
100

Transmitter P/S
18-30VDC

Volume 13

w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c

Limit
Switches
Encoders
Current
Sensors
Pressure
Sensors

Process

200

Transmitter
P/S

Photo
Sensors

Pushbuttons/
Lights

ADxI
ACOM

Proximity
Sensors

Temperature
Sensors

Internal Module Circuitry

Current
Transmitter

40
104

Analog Current Input Circuit

A/D
Converter
150k

30
85

C0-02DD2-D Analog Specifications - Current Input

ADxV
ACOM

20
68

Surrounding Air Temperature (C/F)

Inputs per Module


Input Range
Resolution
Conversion Time
Input Impedance
Input Stability
Full-Scale Calibration Error
Offset Calibration Error
Accuracy vs. Temperature Error

Internal Module Circuitry

Load
2k minimum

Optical Isolator

Software

4 (Source)
24 VDC
19.2-30 VDC
0.1 A/point , 0.4 A/common
0.2 mA
Y1 : 0.1mA @ 30VDC; Y2-4 : 0.1mA @ 30VDC
Y1: 1 VDC @ 0.1A; Y2-4 : 0.5VDC@ 0.1mA
150 mA for 10 ms
Y1: typ 5 s; max 20 s; Y2-4: < 0.5 ms
Y1: typ 5 s; max 20 s; Y2-4: < 0.5 ms
Logic Side (4 points, red LED)
1 (4 points/common)

C0-02DD2-D Analog Specifications - Voltage Input

Voltage
Transmitter

Programmable
Controllers

+V
V1

AD1V - AD2I

Systems
Overview

Equivalent Output Circuit

Y1 - Y4

Outputs per Module


Operating Voltage Range
Output Voltage Range
Maximum Output Current
Minimum Output Current
Maximum Leakage Current
On Voltage Drop
Maximum Inrush Current
OFF to ON Response
ON to OFF Response
Status Indicators
Commons

Company
Information

Programmable Controllers

e1-53

Relays/
Timers
Comm.
Terminal
Blocks &
Wiring
Power
Circuit
Protection
Enclosures
Tools
Pneumatics
Appendix
Product
Index
Part #
Index

Analog CPU Module Specifications


C0-02DR-D

<--->

4 DC Input/4 Relay Output; 2 Analog In/2 Analog Out Micro PLC

CLICK PLC CPU, 4 DC in / 4 relay out, 2-Ch Analog In / 2-Ch Analog out (current/voltage selectable), requires a 24 VDC power supply,

General Specifications
Wiring Diagram
C0-02DR-D

140 mA
Current Consumption at 24VDC
Terminal Block Replacement Part No. C0-16TB
5.6 oz (160 g)
Weight

24VDC

C1
X1

See Discrete I/O


Specifications - Inputs
(X1 through X4)

X2

X3
PWR

X4

RUN

C2

ERR

Y1

Y2

PORT1

Y3

TX1

Y4

6-27 VDC
6-240 VAC

See Discrete I/O


Specifications Outputs
(Y1 through Y4)

AD1V

Transmitter 0-5V

TX2

AD1 I

Transmitter 4-20mA

RX2

AD2V

Transmitter 0-5V

AD2 I

Transmitter 4-20mA

PORT3

ACOM

RS-485

DA1 I

RX3

DA2V
DA2 I

See Analog
Specifications Voltage & Current
Input
(AD1V through AD2I)

Equivalent Discrete Input Circuit

C0-02DR-D Discrete I/O Specifications - Inputs

OFF Voltage Level


Minimum ON Current
Maximum OFF Current
OFF to ON Response
ON to OFF Response
Status Indicators
Commons

X1-2: Typ 5 mA @ 24 VDC


X3-4: Typ 4 mA @ 24 VDC
X1-2: 4.7 k @ 24 VDC
X3-4: 6.8 k @ 24 VDC
X1-2: > 19 VDC
X3-4: > 19 VDC
X1-2: < 4 VDC
X3-4: < 7 VDC
X1-2: 4.5 mA
X3-4: 3.5 mA
X1-2: 0.1 mA
X3-4: 0.5 mA
X1-2: Typ 5 s Max 20 s*
X3-4: Typ 2 ms Max 10 ms
X1-2: Typ 5 s Max 20 s*
X3-4: Typ 3 ms Max 10 ms
Logic Side (4 points, green LED)
1 (4 points/common)

* Threshold level is 70% amplitude.

Internal Module Circuitry


Optical Isolator
Input
X1-X2

+
+

To high
response
circuit

24
VDC
Optical Isolator

Input
X3-X4

24
VDC

COM
C1

C0-02DR-D Temperature Derating Chart


4
Inputs

Points

4 (Source/Sink)
Inputs per Module
Operating Voltage Range 24 VDC
21.6 - 26.4 VDC
Input Voltage Range

ON Voltage Level

NOTE: WHEN USING ANALOG


CPUS, YOU MUST USE CLICK
PROGRAMMING SOFTWARE VERSION V1.12 OR LATER.

IMPORTANT: YOU CAN USE ONLY ONE TERMINAL (VOLTAGE


YOU MUST ALSO SELECT THE
ANALOG TYPE (VOLTAGE OR CURRENT) IN THE CPU BUILT-IN
I/O SETUP IN THE CLICK PROGRAMMING SOFTWARE
(PULL-DOWN MENU SETUP > CPU BUILT-IN I/O SETUP).

X1 - X4

Input Impedance

300,000 cycles
50,000 cycles
500,000 cycles
200,000 cycles

OR CURRENT) PER CHANNEL.

Transmitter
P/S

Input Current

30 VDC Resistive
30 VDC Solenoid
120 VAC Resistive
120 VAC Solenoid

See Analog
Specifications - Voltage
& Current Output
(DA1V through DA2I)

DA1V

TX3

Voltage & Load Type Load Current: 1 A

ON to OFF = 1 cycle

RX1

PORT2

Typical Relay Life (Operations)


at Room Temperature

2
1
0
0
32

10
50

20
68

30
85

40
104

50 55 C
122 131 F

Surrounding Air Temperature (C/F)


* Use every other input.

There are no ZipLink


pre-wired PLC connection cables and modules
for the analog CPUs.
(Cannot mix discrete I/O
and analog I/O signals
in a ZIPLink cable.)

Volume 13

e1-54

Programmable Controllers

1 - 80 0 - 633 - 0405

Analog CPU Module Specifications


C0-02DR-D (contd)

OUTPUT
Y1-Y4

C0-02DR-D Discrete I/O Specifications - Outputs

AD1V - AD2I

Field I/O

Software

COM
C2

C-more &
other HMI

Motors &
Gearbox

4
Outputs

Steppers/
Servos

2
1

Motor
Controls

0
0
32

Number of Channels
Input Range
Resolution
Conversion Time
Input Impedance
Input Stability
Full-Scale Calibration Error
Offset Calibration Error
Accuracy vs. Temperature Error

2 (voltage/current selectable)
0 - 5 VDC (6 VDC Max.)
12 bit
50 ms
150 k
2 LSB maximum
1.2% maximum
5 mV maximum
100 ppm / C maximum

Analog Voltage Input Circuit

10
50

20
68

30
85

40
104

50 55 C
122 131 F

Surrounding Air Temperature (C/F)


* Use every other output.

C0-02DR-D Analog Specifications - Current Input


Inputs per Module
Input Range
Resolution
Conversion Time
Input Impedance
Input Stability
Full-Scale Calibration Error
Offset Calibration Error
Accuracy vs. Temperature Error

2 (voltage/current selectable)
4 - 20 mA (sink)
12 bit
50 ms
200 
2 LSB
1% maximum
0.1 mA maximum
100 ppm / C maximum

Analog Current Input Circuit

Internal Module Circuitry

A/D
Converter

ACOM
150k

A/D
Converter

ACOM
200

Transmitter
P/S

DA1V - DA2I

C0-02DR-D Analog Specifications - Current Output

C0-02DR-D Analog Specifications - Voltage Output


Outputs per Module
Output Range
Resolution
Conversion Time

2 (voltage/current selectable)
0 - 5 VDC
12 bit
1 ms
2 k minimum (output current
Load Impedance
2.5 mA maximum)
0.8% maximum
Full-Scale Calibration Error
5 mV maximum
Offset Calibration Error
Accuracy vs. Temperature Error 100 ppm / C maximum

Outputs per Module


Output Range
Resolution
Conversion Time
Loop Supply Voltage

Full-Scale Calibration Error


Offset Calibration Error
Accuracy vs. Temperature Error 100 ppm / C maximum

DAxV
D/A
Converter

Load
250
typical

Volume 13

Programmable Controllers

Relays/
Timers
Comm.
Terminal
Blocks &
Wiring
Power
Circuit
Protection
Enclosures
Tools

Part #
Index

100

Transmitter P/S
18-30VDC

w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c

Pressure
Sensors

Product
Index

D/A
Converter

ACOM

Current
Sensors

Appendix

Internal Module Circuitry


DAxI

Internal Module Circuitry

Encoders

Pneumatics

Analog Current Output Circuit

Analog Voltage Output Circuit

ACOM

2 (voltage/current selectable)
4 - 20 mA (sink)
12 bit
1 ms
DC 18 - 30 V
250
Load Power Supply:
DC 18V: 600 maximum
DC 24V: 900 maximum
DC 30V: 1200 maximum
1% maximum
0.1 mA maximum

Load Impedance

Limit
Switches

Process

Transmitter
P/S

Photo
Sensors

Pushbuttons/
Lights

ADxI
Current
Transmitter

Proximity
Sensors

Temperature
Sensors

Internal Module Circuitry

ADxV

Load
2k minimum

Soft
Starters

C0-02DR-D Temperature Derating Chart

C0-02DR-D Analog Specifications - Voltage Input

Voltage
Transmitter

Drives

* Varistor Joule Rating: 20 J

This circuit does not contain built-in protection.


Install protection elements such as a fuse outside the module if necessary.

Points

Output Type
AC Frequency
Maximum Current
Minimum Load Current
Maximum Inrush Current
OFF to ON Response
ON to OFF Response
Status Indicators
Commons per Module
Fuse

4
6-27 VDC6 (-15%/+10%)/
6-240 VAC (-10%/+10%)
Relay, form A (SPST)
47-63 Hz
1 A/point
5 mA @ 5 VDC
3 A for 10 ms
< 15 ms
< 15 ms
Logic Side (4 points, red LED)
1 (4 points/common)
None

Programmable
Controllers

Internal Module Circuitry

6-27 VDC
6-240 VAC
L

Operating Voltage Range

Systems
Overview

Equivalent Output Circuit

Y1 - Y4

Outputs per Module

Company
Information

e1-55

CLICK I/O Module Specifications


C0-08ND3 <--->

8-Point Sink/Source DC Input Module

8-pt 12-24 VDC current sinking or sourcing input


module, 2 commons, isolated, removable terminal
block included (replacement ADC p/n C0-08TB).

Wiring Diagram
PWR

C0-08ND3 Input Specifications

C0-08ND3
12-24V

2.5-5mA

INPUT

Inputs per Module


Operating Voltage Range
Input Voltage Range
Input Current
Maximum Input Current
Input Impedance
ON Voltage Level
OFF Voltage Level
Minimum ON Current
Maximum OFF Current
OFF to ON Response
ON to OFF Response

C1
1
2
3
4
C2
5
6
7
8

12-24VDC

+
+

12-24VDC

N.C.

Status Indicators
Commons
Bus Power Required (24 VDC)
Terminal Block Replacement
Weight

8 (Sink/Source)
12-24 VDC
10.8-26.4 VDC
Typ 5 mA @ 24 VDC
7 mA @ 26.4 VDC
4.7 k @ 24 VDC
> 8.0 VDC
< 3.0 VDC
1.4 mA
0.5 mA
Max 3.5 ms, Typ 2 ms
Max 4 ms, Typ 2.5 ms
Logic Side (8 points, green LED)
Power Indicator (green LED)
2 (4 points/common) Isolated
Max. 30 mA (All Inputs On)
ADC p/n C0-8TB
2.8 oz (80 g)

N.C. = Not Connected

Equivalent Input Circuit


Internal Module Circuitry
Optical Isolator

INPUT
+
+

24 VDC
COM

Input Module Temperature Derating Chart

ZipLink Pre-Wired PLC


Connection Cables and Modules

Points

6
4
2
0
0
32

10
50

20
68

30
85

40
104

50 55 C
122 131 F

Surrounding Temperature (C/F)

ZL-RTB20 20-pin feedthrough connector


module

11-pin connector cable


ZL-C0-CBL11 (0.5 m length)
ZL-C0-CBL11-1 (1.0 m length)
ZL-C0-CBL11-2 (2.0 m length)

Volume 13

e1-56

Programmable Controllers

1 - 80 0 - 633 - 0405

CLICK I/O Module Specifications


C0-08ND3-1

Company
Information
Systems
Overview

<--->

Programmable
Controllers

8-Point Sink/Source DC Input Module

Field I/O

8-pt 3.3-5 VDC current sinking or sourcing input


module, 2 commons, isolated, removable terminal
block included (replacement ADC p/n C0-08TB).

Software
C-more &
other HMI
Drives

Wiring Diagram

Soft
Starters
PWR

3.3-5V

3-5.5mA

INPUT

Inputs per Module


Operating Voltage Range
Input Voltage Range
Input Current
Maximum Input Current
Input Impedance
ON Voltage Level
OFF Voltage Level
Minimum ON Current
Maximum OFF Current
OFF to ON Response
ON to OFF Response

C1
1
2
3
4
C2
5
6
7
8

3.3-5VDC

+
+

3.3-5VDC

+
N.C.

Motors &
Gearbox

C0-08ND3-1 Input Specifications

C0-08ND3-1

Status Indicators
Commons
Bus Power Required (24 VDC)
Terminal Block Replacement
Weight

8 (Sink/Source)
3.3-5 VDC
2.8-5.5 VDC
Typ 5 mA @ 5 VDC
7.5 mA @ 5.5 VDC
680
> 2.2 VDC
< 0.8 VDC
1.4 mA
0.2 mA
Max. 3 ms Typ. 1.6 ms
Max. 4 ms Typ. 2.3 ms
Logic Side (8 points, green LED)
Power Indicator (green LED)
2 (4 points/common) Isolated
Max. 30 mA (All Inputs On)
ADC p/n C0-8TB
2.8 oz (80 g)

Steppers/
Servos
Motor
Controls
Proximity
Sensors
Photo
Sensors
Limit
Switches
Encoders
Current
Sensors
Pressure
Sensors
Temperature
Sensors

N.C. = Not Connected

Pushbuttons/
Lights

Equivalent Input Circuit

Process

Internal Module Circuitry

Relays/
Timers

Optical Isolator

INPUT

Comm.

+
+

Terminal
Blocks &
Wiring

3.3-5 VDC
COM

Input Module Temperature Derating Chart

Power

ZipLink Pre-Wired PLC


Connection Cables and Modules

Circuit
Protection

Points

8
6

Enclosures

Tools

Pneumatics

0
0
32

10
50

20
68

30
85

40
104

50 55 C
122 131 F

Surrounding Temperature (C/F)

Appendix

ZL-RTB20 20-pin feedthrough connector


module

Product
Index

11-pin connector cable


ZL-C0-CBL11 (0.5 m length)
ZL-C0-CBL11-1 (1.0 m length)
ZL-C0-CBL11-2 (2.0 m length)

Part #
Index

Volume 13

w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c

Programmable Controllers

e1-57

CLICK I/O Module Specifications


C0-16ND3

<--->

16-Point Sink/Source DC Input Module

16-pt 24 VDC current sinking or sourcing input module,


4 commons, isolated, removable terminal block included
(replacement ADC p/n C0-16TB).

Wiring Diagram

C0-16ND3
24V

+
+
+

24VDC

+
+

24VDC

C0-16ND3 Input Specifications


INPUT

+
24VDC

4mA

C1
1
2
3
4
C2
5
6
7
8
C3
9
10
11
12
C4
13
14
15
16

24VDC

PWR

Inputs per Module


Input Voltage Range
Operating Voltage Range
Input Current
Maximum Input Current
Input Impedance
ON Voltage Level
OFF Voltage Level
Minimum ON Current
Maximum OFF Current
OFF to ON Response
ON to OFF Response
Status Indicators

16 (Sink/Source)
21.6-26.4 VDC
24 VDC
Typ 4.0 mA @ 24 VDC
5.0 mA @ 26.4 VDC
6.8 k @ 24 VDC
> 19 VDC
< 7 VDC
3.5 mA
0.5 mA
Max. 10 ms Typ. 2 ms
Max. 10 ms Typ. 3 ms
Logic Side (16 points, green LED)
Power Indicator (green LED)
4 (4 points/common) Isolated
Max. 40 mA (All Inputs On)
ADC p/n C0-16TB

Commons
Bus Power Required (24 VDC)
Terminal Block Replacement
3.2 oz (90 g)
Weight

Equivalent Input Circuit


Internal Module Circuitry
Optical Isolator

INPUT

ZipLink Pre-Wired PLC Connection


Cables and Modules for CLICK PLC

+
+

24 VDC
COM

Input Module Temperature Derating Chart

20-pin connector cable


ZL-C0-CBL20 (0.5 m length)
ZL-C0-CBL20-1 (1.0 m length)
ZL-C0-CBL20-2 (2.0 m length)

16

Points

12
8
4
0
0
32

10
50

20
68

30
85

40
104

50 55 C
122 131 F

Surrounding Temperature (C/F)

ZL-RTB20 20-pin
feed-through
connector module

ZL-LTB16-24 sensor
input module

Volume 13

e1-58

Programmable Controllers

1 - 80 0 - 633 - 0405

CLICK I/O Module Specifications

Company
Information
Systems
Overview

C0-08NE3 <--->

Programmable
Controllers

8-Point Sink/Source AC/DC Input Module

Field I/O

8-pt 24 VAC/24 VDC current sinking or sourcing input


module, 2 commons, 4 points per common, removable
terminal block included. (replacement ADC p/n C0-08TB).

Software
C-more &
other HMI
Drives

C0-08NE3

PWR

Inputs per Module


Operating Voltage Range
Input Voltage Range
Peak Voltage
AC Frequency
Input Current
Maximum Input Current
Input Impedance
ON Voltage Level
OFF Voltage Level
Minimum ON Current
Maximum OFF Current
OFF to ON Response
ON to OFF Response

24V50/60Hz 3.4mA/pt.
24V 3.4mA/pt.

INPUT

24 VAC

24 VDC

C1
C1
1
2
3
4
C2
C
2
5
6
7
8

+
24 VDC

24 VAC

Soft
Starters

C0-08NE3 Input Specifications

Wiring Diagram

+
N.C.

Status Indicators
Commons
Bus Power Required (24 VDC)
Terminal Block Replacement
Weight

8 (Sink/Source)
24 VAC/VDC
20.4 - 27.6 VAC/VDC
27.6 VAC/VDC
47-63 Hz
Typ 3.4 mA @ 24 VAC/VDC
5.0 mA @ 27.6 VAC/VDC
6.8 k @ 24 VAC/VDC
> 18.0 VAC/VDC
< 4.0 VAC/VDC
2.5 mA
0.5 mA
5-40 ms
10-50 ms
Logic Side (8 points, green LED)
Power Indicator (green LED)
2 (4 points/common) Isolated
Max. 30 mA (All Inputs On)
ADC p/n C0-8TB
2.9 oz (82 g)

Motors &
Gearbox
Steppers/
Servos
Motor
Controls
Proximity
Sensors
Photo
Sensors
Limit
Switches
Encoders
Current
Sensors
Pressure
Sensors
Temperature
Sensors

N.C. = Not Connected

NOTE: When using this module you must also use


CLICK programming software version V1.20 or later.

Pushbuttons/
Lights

ZipLink Pre-Wired PLC


Connection Cables and Modules

Process
Relays/
Timers

Equivalent Input Circuit


24VAC

Comm.

Internal Module Circuitry

24 VDC

Terminal
Blocks &
Wiring

Optical Isolator

INPUT
+
+

ZL-RTB20 20-pin feedthrough connector


module

COM

11-pin connector cable


ZL-C0-CBL11 (0.5 m length)
ZL-C0-CBL11-1 (1.0 m length)
ZL-C0-CBL11-2 (2.0 m length)

Points

Input Module Temperature Derating Chart

Power
Circuit
Protection
Enclosures

Tools

Pneumatics

Appendix

Product
Index

0
0
32

10
50

20
68

30
85

40
104

Part #
Index

50 55 C
122 131 F

Surrounding Air Temperature (C/F)

Volume 13

w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c

Programmable Controllers

e1-59

CLICK I/O Module Specifications


C0-16NE3

<--->

16-Point Sink/Source AC/DC Input Module

16-pt 24 VAC/24 VDC current sinking or sourcing input module,


4 commons, 4 points per common, removable terminal block
included. (replacement ADC p/n C0-16TB).

Wiring Diagram
24VAC

PWR

24VDC

24V50/60Hz 3.4mA/pt.
24V 3.4mA/pt.

+
24VDC

+
+
24VAC

24VDC

+
+
24VAC

24VDC

INPUT

C1
1
2
3
4
C2
5
6
7
8
C3
9
10
11
12
C4
13
14
15
16

+
24VAC

C0-16NE3 Input Specifications

C0-16NE3

Inputs per Module


Operating Voltage Range
Input Voltage Range
Peak Voltage
AC Frequency
Input Current
Maximum Input Current
Input Impedance
ON Voltage Level
OFF Voltage Level
Minimum ON Current
Maximum OFF Current
OFF to ON Response
ON to OFF Response
Status Indicators

+
+

Commons
Bus Power Required (24 VDC)
Terminal Block Replacement
Weight

NOTE: When using this module you must also use


CLICK programming software version V1.20 or later.

16 (Sink/Source)
24 VAC/VDC
20.4 - 27.6 VAC/VDC
27.6 VAC/VDC
47-63 Hz
Typ 3.4 mA @ 24 VAC/VDC
5.0 mA @ 27.6 VAC/VDC
6.8 k @ 24 VAC/VDC
> 18.0 VAC/VDC
< 4.0 VAC/VDC
2.5 mA
0.5 mA
5-40 ms
10-50 ms
Logic Side (16 points, green LED)
Power Indicator (green LED)
4 (4 points/common) Isolated
Max. 40 mA (All Inputs On)
ADC p/n C0-16TB
3.2 oz (90 g)

ZipLink Pre-Wired PLC Connection


Cables and Modules for CLICK PLC

Equivalent Input Circuit


24 VAC

Internal Module Circuitry

24 VDC

Optical Isolator

INPUT
+
+

20-pin connector cable


ZL-C0-CBL20 (0.5 m length)
ZL-C0-CBL20-1 (1.0 m length)
ZL-C0-CBL20-2 (2.0 m length)

COM

Input Module Temperature Derating Chart


16

Points

12
8
4
0
0
32

10
50

20
68

30
85

40
104

50 55 C
122 131 F

ZL-RTB20 20-pin
feed-through
connector module

ZL-LTB16-24 sensor
input module

Surrounding Air Temperature (C/F)

Volume 13

e1-60

Programmable Controllers

1 - 80 0 - 633 - 0405

CLICK I/O Module Specifications


C0-08NA

Company
Information
Systems
Overview

<--->

Programmable
Controllers

8-Point AC Input Module

Field I/O

8-pt 100-120 VAC input module, 2 commons,


isolated, removable terminal block included
(replacement ADC p/n C0-08TB).

Wiring Diagram

Software
C-more &
other HMI
Drives

C0-08NA Input Specifications


PWR

Inputs per Module


Operating Voltage Range
Input Voltage Range
AC Frequency

C0-08NA

100-120V10mA
50-60Hz

INPUT

Input Current
Maximum Input Current
Input Impedance
ON Voltage Level
OFF Voltage Level
Minimum ON Current
Maximum OFF Current
OFF to ON Response
ON to OFF Response

C1
1
2
3
4
C2
5
6
7
8

100 - 120VAC

100 - 120VAC

Status Indicators

Soft
Starters

8
100-120 VAC
80-144 VAC
47-63 Hz
Typ 8.5 mA @ 100 VAC (50Hz)
Typ 10 mA @ 100 VAC (60Hz)
16 mA @ 144 VAC
15 k (50 Hz), 12 k (60 Hz)
> 70 VAC
< 20 VAC
5 mA
2 mA
< 40 ms
< 40 ms
Logic Side (8 points, green LED)
Power Indicator (green LED)
2 (4 points/common) Isolated

Motors &
Gearbox
Steppers/
Servos
Motor
Controls
Proximity
Sensors
Photo
Sensors
Limit
Switches
Encoders

Commons
Bus Power Required (24 VDC) Max. 30mA (All Inputs On)
Terminal Block Replacement ADC p/n C0-8TB
2.8 oz (80 g)
Weight

Current
Sensors
Pressure
Sensors

N.C.

Temperature
Sensors

N.C. = Not Connected

Pushbuttons/
Lights

Equivalent Input Circuit

Process

Internal Module Circuitry


INPUT

Relays/
Timers

Optical Isolator

Comm.

100-120 VAC

Terminal
Blocks &
Wiring

COM

Input Module Temperature Derating Chart

Power

ZipLink Pre-Wired PLC


Connection Cables and Modules

Circuit
Protection

Points

8
6

Enclosures

Tools
Pneumatics

Appendix

0
0
32

10
50

20
68

30
85

40
104

50 55 C
122 131 F

Surrounding Temperature (C/F)

ZL-RTB20 20-pin feedthrough connector


module

Product
Index

11-pin connector cable


ZL-C0-CBL11 (0.5 m length)
ZL-C0-CBL11-1 (1.0 m length)
ZL-C0-CBL11-2 (2.0 m length)

Part #
Index

Volume 13

w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c

Programmable Controllers

e1-61

CLICK I/O Module Specifications


C0-08TD1

<--->

8-Point Sinking DC Output Module

8-pt 3.3-27 VDC current sinking output module,


2 commons, 0.3 A/pt, removable terminal block
included (replacement ADC p/n C0-08TB).

Wiring Diagram

C0-08TD1 Output Specifications

PWR

C0-08TD1
C0
08TD1

3.3-27V 0.3A

OUTPUT
C1
1
2
3
4
C2
5
6
7
8
+V

L
+

3.3 - 27VDC

L
L
L
L
L

24VDC

3.3 - 27VDC

L
L

Outputs per Module


Operating Voltage Range
Output Voltage Range
Maximum Output Current
Minimum Output Current
Maximum Leakage Current
On Voltage Drop
Maximum Inrush Current
OFF to ON Response
ON to OFF Response

8 (Sink)

Status Indicators

Logic Side (8 points, red LED)


Power Indicator (green LED)

Commons

2 (4 points/common)

External DC Power Required

21.6-26.4 VDC Max 15 mA


(All Outputs On)

3.3-27 VDC
2.8-30 VDC
0.3 A/point , 1.2 A/common
0.5 mA
0.1 mA @ 30.0 VDC
1.5 VDC @ 0.3 A
1 A for 10 ms
< 0.5 ms
< 0.5 ms

Bus Power Required (24 VDC) Max. 50 mA (All Outputs On)


Terminal Block Replacement ADC p/n C0-8TB
2.8 oz (80 g)
Weight

Equivalent Output Circuit


Internal Module Circuitry
24 VDC
+
+

+V

Optical Isolator

OUTPUT

3.3 - 27 VDC

*
COM

* Zener Diode Power Dissipation: 200 mW

Output Module Temperature Derating Chart

ZipLink Pre-Wired PLC


Connection Cables and Modules

Points

6
4
2
0
0
32

10
50

20
68

30
85

40
104

50 55 C
122 131 F

Surrounding Temperature (C/F)

ZL-RTB20 20-pin feedthrough connector


module

11-pin connector cable


ZL-C0-CBL11 (0.5 m length)
ZL-C0-CBL11-1 (1.0 m length)
ZL-C0-CBL11-2 (2.0 m length)

Volume 13

e1-62

Programmable Controllers

1 - 80 0 - 633 - 0405

CLICK I/O Module Specifications


C0-08TD2

Company
Information
Systems
Overview

<--->

Programmable
Controllers

8-Point Sourcing DC Output Module

Field I/O

8-pt 12-24 VDC current sourcing output module,


1 common, 0.3 A/pt, removable terminal block included
(replacement ADC p/n C0-08TB).

Software
C-more &
other HMI

Wiring Diagram

Drives
PWR

C0-08TD2

OUTPUT

Outputs per Module


Operating Voltage Range
Output Voltage Range
Maximum Output Current
Minimum Output Current
Maximum Leakage Current
On Voltage Drop
Maximum Inrush Current
OFF to ON Response
ON to OFF Response

V1
1
2
3
4
V2
5
6
7
8
C

L
L
+

12 - 24VDC

L
L
L
L
+

L
L

12 - 24VDC

Soft
Starters

C0-08TD2 Output Specifications

12-24V 0.3A

Status Indicators
Commons
Bus Power Required (24 VDC)
Terminal Block Replacement
Weight

Motors &
Gearbox

8 (Source)
12-24 VDC
9.6-30 VDC
0.3 A/point , 1.2 A/common
0.5 mA
0.1 mA @ 30.0 VDC
1.5 VDC @ 0.3 A
1 A for 10 ms
< 1 ms
< 1 ms
Logic Side (8 points, red LED)
Power Indicator (green LED)
1 (8 points/common)
Max. 50 mA (All Outputs On)
ADC p/n C0-8TB
2.8 oz (80 g)

Steppers/
Servos
Motor
Controls
Proximity
Sensors
Photo
Sensors
Limit
Switches
Encoders
Current
Sensors
Pressure
Sensors
Temperature
Sensors
Pushbuttons/
Lights

Equivalent Output Circuit

12-24 VDC
+

+V

Process

Internal Module Circuitry


Optical Isolator

Relays/
Timers

OUTPUT

Comm.

COM

Terminal
Blocks &
Wiring

* Zener Diode Power Dissipation: 200 mW

Power

Output Module Temperature Derating Chart

Circuit
Protection

ZipLink Pre-Wired PLC


Connection Cables and Modules

Points

Enclosures

Tools

Pneumatics

0
0
32

10
50

20
68

30
85

40
104

Appendix

50 55 C
122 131 F

Surrounding Temperature (C/F)

ZL-RTB20 20-pin feedthrough connector


module

11-pin connector cable


ZL-C0-CBL11 (0.5 m length)
ZL-C0-CBL11-1 (1.0 m length)
ZL-C0-CBL11-2 (2.0 m length)
Volume 13

w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c

Programmable Controllers

e1-63

Product
Index
Part #
Index

CLICK I/O Module Specifications


C0-16TD1

<--->

16-Point Sinking DC Output Module

16-pt 5-27 VDC current sinking output module,


2 commons, isolated, 0.1 A/pt, removable terminal
block included (replacement ADC p/n C0-16TB).

Wiring Diagram

C0-16TD1 Output Specifications


PWR

C0-16TD1

5-27V 0.1A

L
L
L
L

L
L

5 - 27VDC

L
L
+

24VDC

L
L
L
L

L
L

5 - 27VDC

OUTPUT

C1
1
2
3
4
V1
5
6
7
8
C2
9
10
11
12
V2
13
14
15
16

L
24VDC

Outputs per Module


Operating Voltage Range
Output Voltage Range
Maximum Output Current
Minimum Output Current
Maximum Leakage Current
On Voltage Drop
Maximum Inrush Current
OFF to ON Response
ON to OFF Response
Status Indicators
Commons
External DC Power Required
Bus Power Required (24 VDC)
Terminal Block Replacement
Weight

Equivalent Output Circuit

16 (Sink)
5-27 VDC
4-30 VDC
0.1 A/point , 0.8 A/common
0.2 mA
0.1 mA @ 30.0 VDC
0.5 VDC @ 0.1 A
150 mA for 10 ms
< 0.5 ms
< 0.5 ms
Logic Side (16 points, red LED)
Power Indicator (green LED)
2 (8 Points/common) Isolated
21.6-26.4 VDC Max 100 mA
(All Outputs On)
Max. 80 mA (All Outputs On)
ADC p/n C0-16TB
3.2 oz (90 g)

ZipLink Pre-Wired PLC Connection


Cables and Modules for CLICK PLC

Internal Module Circuitry


24 VDC
+

+V

Optical Isolator

OUTPUT

5 - 27 VDC

20-pin connector cable


ZL-C0-CBL20 (0.5 m length)
ZL-C0-CBL20-1 (1.0 m length)
ZL-C0-CBL20-2 (2.0 m length)

*
COM
* Zener Diode Power Dissipation: 200 mW

Output Module Temperature Derating Chart


16

Points

12
8

ZL-RTB20 20-pin
feed-through
connector module

4
0
0
32

10
50

20
68

30
85

40
104

ZL-RFU20
fuse module

ZL-RRL16-24-1 relay module


Note: 10A/Point (DC)
8A/Point (AC)
(Replaceable relays)

50 55 C
122 131 F

Surrounding Temperature (C/F)

Volume 13

e1-64

Programmable Controllers

1 - 80 0 - 633 - 0405

CLICK I/O Module Specifications


C0-16TD2

Company
Information
Systems
Overview

<--->

Programmable
Controllers

16-Point Sourcing DC Output Module

Field I/O

16-pt 12-24 VDC current sourcing output module,


2 commons, isolated, 0.1 A/pt, removable terminal block
included (replacement ADC p/n C0-16TB).

Software
C-more &
other HMI

Wiring Diagram

Drives

PWR

C0-16TD2
12-24V

L
L
L
L
L
L
L
L
+

12 - 24VDC

L
L
L
L
L
L

Outputs per Module


Operating Voltage Range
Output Voltage Range
Maximum Output Current
Minimum Output Current
Maximum Leakage Current
On Voltage Drop
Maximum Inrush Current
OFF to ON Response
ON to OFF Response

OUTPUT

12 - 24VDC

C0-16TD2 Output Specifications

0.1A

V1
1
2
3
4
C1
5
6
7
8
V2
9
10
11
12
C2
13
14
15
16

Soft
Starters

Status Indicators
Commons
Bus Power Required (24 VDC)
Terminal Block Replacement
Weight

Motors &
Gearbox

16 (Source)
12-24 VDC
9.6-30.0 VDC
0.1 A/point , 0.8 A/common
0.2 mA
0.1 mA @ 30.0 VDC
0.6 VDC @ 0.1 A
150 mA for 10 ms
< 0.5 ms
< 0.5 ms
Logic Side (16 points, red LED)
Power Indicator (green LED)
2 (8 points/common) Isolated
Max. 80 mA (All Outputs On)
ADC p/n C0-16TB
3.2 oz (90 g)

Steppers/
Servos
Motor
Controls
Proximity
Sensors
Photo
Sensors
Limit
Switches
Encoders
Current
Sensors
Pressure
Sensors
Temperature
Sensors

ZipLink Pre-Wired PLC Connection


Cables and Modules for CLICK PLC
12-24 VDC
+

+V

Process

Internal Module Circuitry

Relays/
Timers

Optical Isolator

20-pin connector cable


ZL-C0-CBL20 (0.5 m length)
ZL-C0-CBL20-1 (1.0 m length)
ZL-C0-CBL20-2 (2.0 m length)

OUTPUT

Pushbuttons/
Lights

Equivalent Output Circuit

COM

Comm.
Terminal
Blocks &
Wiring

* Zener Diode Power Dissipation: 200 mW

Power
Circuit
Protection

Output Module Temperature Derating Chart

Enclosures

12

Tools

Points

16

ZL-RTB20 20-pin
feed-through
connector module

4
0
0
32

10
50

20
68

30
85

40
104

50 55 C
122 131 F

ZL-RFU20
fuse module

ZL-RRL16-24-2 relay module


Note: 10A/Point (DC)
8A/Point (AC)
(Replaceable relays)

Surrounding Temperature (C/F)

Appendix
Product
Index
Part #
Index

Volume 13

w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c

Pneumatics

Programmable Controllers

e1-65

CLICK I/O Module Specifications


C0-08TA

<--->

8-POINT AC OUTPUT MODULE

8-pt 17-240 VAC triac output module, 2 commons,


isolated, 0.3 A/pt, removable terminal block included
(replacement ADC p/n C0-08TB).

Wiring Diagram

PWR

C0-08TA Output Specifications

C0-08TA

Outputs per Module


Operating Voltage Range
Output Voltage Range
AC Frequency
Maximum Output Current
Minimum Load
Maximum Leakage Current

17-240V
V 0.3A
50-60Hz

OUTPUT

On Voltage Drop
17- 240VAC

L
L
L
L

17- 240VAC

Maximum Inrush Current


OFF to ON Response
ON to OFF Response

C1
1
2
3
4
C2
5
6
7
8

L
L
L
L

Status Indicators
Commons
Bus Power Required (24 VDC)
Protection Circuit
Terminal Block Replacement
Weight

8
17-240 VAC
13.5-288 VAC
47-63 Hz
0.3 A/point, 1.2 A/common
10 mA
4 mA @ 288 VAC
1.5 VAC @ > 0.1 A
3.0 VAC @ < 0.1 A
10 A for 10 ms
1 ms
1 ms + 1/2cycle
Logic Side (8 points, red LED)
Power Indicator (green LED)
2 (4 points/common) Isolated
Max. 80 mA (All Outputs On)
Not built into the module - Install protection
elements such as external fuse.
ADC p/n C0-8TB
3.5 oz (100 g)

N.C.

N.C. = Not Connected

Equivalent Output Circuit


Internal Module Circuitry

17-240 VAC

OUTPUT

Optical Isolator

COM

* Varistor Joule Rating: 20 J

ZipLink Pre-Wired PLC


Connection Cables and Modules

Output Temperature Derating Chart


8

0.2 A/pt.

Points

6
0.3 A/pt. *

4
2
0
0
32

10
50

20
68

30
85

40
104

50 55 C
122 131 F

Surrounding Air Temperature (C/F)

* Use every other output.

ZL-RTB20 20-pin feedthrough connector


module

11-pin connector cable


ZL-C0-CBL11 (0.5 m length)
ZL-C0-CBL11-1 (1.0 m length)
ZL-C0-CBL11-2 (2.0 m length)

Volume 13

e1-66

Programmable Controllers

1 - 80 0 - 633 - 0405

CLICK I/O Module Specifications


C0-04TRS

Company
Information
Systems
Overview

<--->

Programmable
Controllers

4-Point Relay Output Module

Field I/O

4-pt 6-240 VAC/6-27 VDC Isolated relay output module, 4 Form C


(SPDT) relays, 4 isolated commons, 7 A/point, removable terminal block
included (replacement ADC p/n C0-16TB).

Software
C-more &
other HMI

Wiring Diagram
PWR

Drives

250V
V7A
7 50-60Hz
30V 7A

6 - 27VDC
6 - 240VAC

L
6 - 27VDC
6 - 240VAC

C2
NC2
NO2

L
L
6 - 27VDC
6 - 240VAC

N.C.
N.C.

N.C.
N.C.

C3
NC3
NO3

Outputs per Module


Operating Voltage Range
Output Voltage Range
Output Type
AC Frequency
Maximum Current
Minimum Load Current
Maximum Leakage Current
Maximum Inrush Current
OFF to ON Response
ON to OFF Response

N.C.

OUTPUT

C1
NC1
NO1

Status Indicators
Commons
Bus Power Required (24 VDC)

N.C.
N.C.

6 - 27VDC
6 - 240VAC

C4
NC4
NO4

L
L

Soft
Starters

C0-04TRS Output Specifications

C0-04TRS

Protection Circuit
Terminal Block Replacement
Weight

Motors &
Gearbox

4
6-27 VDC / 6-240 VAC
5-30 VDC / 5-264 VAC
Relay, form C (SPDT)
47-63 Hz
7 A/point, 7 A/common
100 mA @ 5 VDC
0.1 mA @ 264 VAC
12 A
< 15 ms
< 15 ms
Logic Side (4 points, red LED)
Power Indicator (green LED)
4 (1 point/common) Isolated
Max. 100 mA (All Outputs On)
Not built into the module - Install protection
elements such as external fuse
ADC p/n C0-16TB
4.4 oz (125 g)

Steppers/
Servos
Motor
Controls
Proximity
Sensors
Photo
Sensors
Limit
Switches
Encoders
Current
Sensors
Pressure
Sensors

N.C.

Temperature
Sensors

Typical Relay Life (Operations)


at Room Temperature

L
6-27 VDC
6-240 VAC

N.C. = Not Connected

Voltage & Load Type

Relay Life

Equivalent Output Circuit

30 VDC, 7 A Resistive
250 VAC, 7 A Resistive
250 VAC, 4.9 A Solenoid
250 VAC, 2.9 A Solenoid

100,000 cycles
100,000 cycles
90,000 cycles
100,000 cycles

Internal Module Circuitry

NC

Process
Relays/
Timers

ON to OFF = 1 cycle

Comm.

COM

Terminal
Blocks &
Wiring

ZipLink Pre-Wired PLC


Connection Cables and Modules

*
L

Pushbuttons/
Lights

NO

Power
Circuit
Protection

* Varistor Joule Rating: 20 J

Enclosures

Output Temperature Derating Chart


5 A/pt. *

Points

3
7 A/pt.

ZL-RTB20 20-pin feedthrough connector


module

20-pin connector cable


ZL-C0-CBL20 (0.5 m length)
ZL-C0-CBL20-1 (1.0 m length)
ZL-C0-CBL20-2 (2.0 m length)

0
32

10
50

20
68

30
85

40
104

50 55 C
122 131 F

Surrounding Air Temperature (C/F)

* No derating when the load current is 5A or less for each output point.

NOTE: THE CO-04TRS

RELAY OUTPUT

MODULE IS DERATED TO

2A

MAXIMUM

WHEN

USED

THE

ZIPLINK WIRING SYSTEM.


Volume 13

w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c

Programmable Controllers

Appendix

Part #
Index

PER POINT

WITH

Pneumatics

Product
Index

1
0

Tools

e1-67

CLICK I/O Module Specifications


C0-08TR

<--->

8-Point Relay Output Module

8-point 6-240 VAC/6-27 VDC relay output module, 8 Form A


(SPST) relays, 2 commons, isolated, 1 A/point, removable
terminal block included (replacement ADC p/n C0-08TB).

Wiring Diagram

PWR

C0-08TR Output Specifications

C0-08TR

Outputs per Module


Operating Voltage Range
Output Voltage Range
Output type
AC Frequency
Maximum Current (resistive)
Minimum Load Current
Maximum Leakage Current
Maximum Inrush Current
OFF to ON Response
ON to OFF Response

250V
V1A 50-60Hz
30V 1A

OUTPUT

6 - 27VDC
6 - 240VAC

C1
1
2
3
4
C2
5
6
7
8

L
L
L
L
6 - 27VDC
6 - 240VAC

L
L
L
L

Status Indicators
Commons
Bus Power Required (24 VDC)
Protection Circuit
Terminal Block Replacement
Weight

N.C.

N.C. = Not Connected

Typical Relay Life (Operations)


at Room Temperature

Equivalent Output Circuit

Voltage & Load Type Load Current: 1 A


30 VDC Resistive
30 VDC Solenoid
250 VAC Resistive
250 VAC Solenoid

Internal Module Circuitry

6-27 VDC
6-240 VAC

OUTPUT

8
6-27 VDC / 6-240 VAC
5-30 VDC / 5-264 VAC
Relay, form A (SPST)
47-63 Hz
1 A/point, 4 A/common
5 mA @ 5 VDC
0.1 mA @ 264 VAC
3 A for 10 ms
< 15 ms
< 15 ms
Logic Side (8 points, red LED)
Power Indicator (green LED)
2 (4 points/common) Isolated
Max. 100 mA (All Outputs On)
Not built into the module - Install protection
elements such as external fuse
ADC p/n C0-8TB
3.9 oz (110 g)

300,000 cycles
50,000 cycles
500,000 cycles
200,000 cycles

ON to OFF = 1 cycle

COM

ZipLink Pre-Wired PLC


Connection Cables and Modules

* Varistor Joule Rating: 20 J

Output Temperature Derating Chart


8

Points

4
2
0
0
32

10
50

20
68

30
85

40
104

50 55 C
122 131 F

Surrounding Air Temperature (C/F)


* Use every other output.

ZL-RTB20 20-pin feedthrough connector


module

11-pin connector cable


ZL-C0-CBL11 (0.5 m length)
ZL-C0-CBL11-1 (1.0 m length)
ZL-C0-CBL11-2 (2.0 m length)

Volume 13

e1-68

Programmable Controllers

1 - 80 0 - 633 - 0405

CLICK I/O Module Specifications


C0-16CDD1

<--->

8-Point DC Input and 8-Point DC Sinking Output


Module

Company
Information
Systems
Overview

C0-16CDD1 Input Specifications


Inputs per Module
Operating Voltage Range

8 (Source/Sink)
CE: 24 VDC (-10%/+10%)
UL: 24 VDC (-10%/+10%)
21.6 - 26.4 VDC
Typ 4.0 mA @ 24 VDC
5.0 mA @ 26.4 VDC
6.8 k @ 24 VDC
>19.0 VDC
<7.0 VDC
3.5 mA
0.5 mA
Max. 10 ms Typ. 2 ms
Max. 10 ms Typ. 3 ms
Logic Side (8 points, green LED)
Power Indicator (green LED)
1 (8 points/common)

Input Voltage Range


8-point 24VDC current sinking/sourcing input, 1 common, 8-point Input Current
5-27 VDC sinking output, 0.1A/pt., 1 common, non-fused, removable Maximum Input Current
terminal block included. (replacement ADC p/n C0-16TB).
Input Impedance
ON Voltage Level
OFF Voltage Level
Wiring Diagram
Minimum ON Current
C0-16CDD1
PWR
24V 4mA
Maximum OFF Current
OFF to ON Response
C1
1
ON to OFF Response

N.C.

L
L

24
VDC

L
L

5-27
VDC

L
L

5-27V

Status Indicators
Commons

C0-16CDD1 Output Specifications


Outputs per Module
Operating Voltage Range
Output Voltage Range
Maximum Output Current
Minimum Output Current
Maximum Leakage Current
On Voltage Drop
Maximum Inrush Current
OFF to ON Response
ON to OFF Response
Status Indicators
Commons

OUTPUT

5
6
7
8
C2
1
2
3
4
+V
5
6
7
8

INPUT

24
VDC

2
3
4

0.1A

N.C. = Not Connected

External DC Power Required

NOTE: When using this module you must also use CLICK
programming software and CPU firmware version V1.40 or later.

Equivalent Input Circuit

C0-16CDD1 General Specifications


Bus Power Required (24 VDC) Max. 80 mA (all points on)
Terminal Block Replacement ADC p/n C0-16TB
3.2 oz (90 g)
Weight

+
+

6
4

COM

0
32

Equivalent Output Circuit

+V
L

10
50

20
68

30
85

40
104

50 55 C
122 131 F

Surrounding Air Temperature (C/F)

ZipLink Pre-Wired PLC Connection


Cables and Modules for CLICK PLC

Internal Module Circuitry


24 VDC
+

Optical Isolator

* Zener Diode Power Dissipation: 200 mW

ZL-RTB20 20-pin
feed-through
connector module

20-pin connector cable


ZL-C0-CBL20 (0.5 m length)
ZL-C0-CBL20-1 (1.0 m length)
ZL-C0-CBL20-2 (2.0 m length)

Motors &
Gearbox
Steppers/
Servos
Motor
Controls
Proximity
Sensors
Photo
Sensors
Limit
Switches
Encoders
Current
Sensors
Pressure
Sensors
Temperature
Sensors
Pushbuttons/
Lights
Process
Relays/
Timers

Circuit
Protection
Enclosures
Tools
Pneumatics

Part #
Index

Volume 13

w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c

Soft
Starters

Product
Index

*
COM

Drives

Appendix

OUTPUT

5 - 27 VDC

C-more &
other HMI

Power

24 VDC

Software

Terminal
Blocks &
Wiring

Points

Optical Isolator

Field I/O

Comm.

Input / Output Temperature Derating Chart

Internal Module Circuitry


INPUT

8 (sink)
CE: 5-24 VDC (-15%/+20%)
UL: 5-27 VDC (-15%/+20%)
4-30 VDC
0.1 A/point, 0.8 A/common
0.2 mA
0.1 mA @ 30 VDC
0.5 VDC @ 0.1 A
0.15 A for 10 ms
< 0.5 ms
< 0.5 ms
Logic Side (8 points, red LED)
1 (8 points/common)
24 VDC (-10%/+10%)
max. 50 mA (all points on)

Programmable
Controllers

Programmable Controllers

e1-69

CLICK I/O Module Specifications


C0-16CDD2

<--->

8-Point DC Input and 8-Point DC Sourcing Output


Module

8-point 24VDC current sinking/sourcing input , 1 common, 8-point


12-24 VDC sourcing output, 0.1A/pt., 1 common, non-fused, removable terminal block included. (replacement ADC p/n C0-16TB).

Wiring Diagram

L
L
L
L

L
L
L
L

12-24V

4mA

Inputs per Module


Operating Voltage Range

8 (source/sink)
CE: 24 VDC (-10%/+10%)
UL: 24 VDC (-10%/+10%)
21.6 - 26.4 VDC
Typ 4.0 mA @ 24 VDC
5.0 mA @ 26.4 VDC
6.8 k @ 24 VDC
>19.0 VDC
<7.0 VDC
3.5 mA
0.5 mA
Max. 10 ms Typ. 2 ms
Max. 10 ms Typ. 3 ms
Logic Side (8 points, green LED)
Power Indicator (green LED)
1 (8 points/common)

Input Voltage Range


Input Current
Maximum Input Current
Input Impedance
ON Voltage Level
OFF Voltage Level
Minimum ON Current
Maximum OFF Current
OFF to ON Response
ON to OFF Response
Status Indicators
Commons

C0-16CDD2 Output Specifications


Outputs per Module

8 (Source)
CE: 12-24 VDC (-15%/+20%)
UL: 12-24 VDC (-20%/+25%)
9.6 - 30 VDC
0.1 A/point , 0.8 A/common
0.2 mA
0.1 mA @ 30 VDC
0.6 VDC @ 0.1 A
0.15 A for 10 ms
<0.5 ms
<0.5 ms
Logic Side (8 points, red LED)
1 (8 points/common)

Operating Voltage Range


Output Voltage Range
Maximum Output Current
Minimum Output Current
Maximum Leakage Current
On Voltage Drop
Maximum Inrush Current
OFF to ON Response
ON to OFF Response
Status Indicators
Commons

OUTPUT

5
6
7
8
+V
1
2
3
4
C2
5
6
7
8

24
VDC

24
VDC

24V

C1
1
2
3
4

N.C.

C0-16CDD2

INPUT

PWR

C0-16CDD2 Input Specifications

0.1A

N.C. = Not Connected

C0-16CDD2 General Specifications

NOTE: When using this module you must also use CLICK
programming software and CPU firmware version V1.40 or later.

Bus Power Required (24 VDC) Max. 80 mA (all points on)


Terminal Block Replacement ADC p/n C0-16TB
3.2 oz (90 g)
Weight

Equivalent Input Circuit

Input / Output Temperature Derating Chart


8

Internal Module Circuitry

+
+

4
2

24 VDC

COM

12-24 VDC
+

0
32

Equivalent Output Circuit


+V

10
50

20
68

30
85

40
104

50 55 C
122 131 F

Surrounding Air Temperature (C/F)

ZipLink Pre-Wired PLC Connection


Cables and Modules for CLICK PLC

Internal Module Circuitry


*

Points

Optical Isolator

INPUT

Optical Isolator

OUTPUT
COM

* Zener Diode Power Dissipation: 200 mW

ZL-RTB20 20-pin
feed-through
connector module

20-pin connector cable


ZL-C0-CBL20 (0.5 m length)
ZL-C0-CBL20-1 (1.0 m length)
ZL-C0-CBL20-2 (2.0 m length)

Volume 13

e1-70

Programmable Controllers

1 - 80 0 - 633 - 0405

CLICK I/O Module Specifications


C0-08CDR

C0-08CDR Input Specifications

<--->

Inputs per Module


Operating Voltage Range

4-Point DC Input and 4-Point Relay Output Module

Input Voltage Range


Input Current
4-point 12-24 VDC current sinking/sourcing input, 1 common, 4-point
Maximum Input Current
6.25-24 VDC / 6-240 VAC relay output, Form A (SPST) relays 1A/pt.,
Input Impedance
1 common, non-fused, removable terminal block included. (replaceON Voltage Level
ment ADC p/n C0-8TB).
OFF Voltage Level
Minimum ON Current
Maximum OFF Current
OFF to ON Response
Wiring Diagram
ON to OFF Response
C0-08CDR
PWR

12-24V

2.5-5mA

Status Indicators
Commons

INPUT

24VDC
240VAC

L
L
L
L

Peak Voltage
Output Type
AC Frequency
Maximum Current
Minimum Load Current
Maximum Leakage Current
Maximum Inrush Current
OFF to ON Response
ON to OFF Response
Status Indicators
Commons

OUTPUT

C1
1
2
3
4
C2
1
2
3
4

N.C.
250V

4 (source/sink)
CE: 12-24 VDC (-10%/+10%)
UL: 12-24 VDC (-10%/+10%)
10.8 - 26.4 VDC
Typ 5.0 mA @ 24 VDC
7.0 mA @ 26.4 VDC
4.7 k @ 24 VDC
>8.0 VDC
<3.0 VDC
1.4 mA
0.5 mA
Max. 3.5 ms Typ. 2 ms
Max. 4 ms Typ. 2.5 ms
Logic Side (4 points, green LED)
Power Indicator (green LED)
1 (4 points/common)

C0-08CDR Output Specifications


Outputs per Module
Operating Voltage Range

12-24VDC

Company
Information

30V 1A
1A 50-60Hz

4 (Relay)
CE: 6.25 - 24 VDC (-15%/+10%) /
6 - 240 VAC (-15%/+10%)
UL: 24 VDC (-15%/+10%) /
240 VAC (-10%/+10%)
30 VDC / 264 VAC
Relay, Form A (SPST)
47-63 Hz
1 A/point, 4 A/common
5mA @ 5VDC
0.1 mA @ 264 VAC
3 A for 10 ms
<15 ms
<15 ms
Logic Side (4 points, red LED)
1 (4 points/common)

C0-08CDR General Specifications


Bus Power Required (24 VDC) Max. 80 mA (all points on)

N.C. = Not Connected

Protection Circuit

NOTE: When using this module you must also use CLICK
programming software and CPU firmware version V1.40 or later.

Terminal Block Replacement


Weight

C0-08CDR Typical Relay Life


(Operations) at Room Temperature

Equivalent Input Circuit

Voltage & Load Type*

Internal Module Circuitry


INPUT

12-24 VDC
COM

Input / Output Temperature Derating Chart

Internal Module Circuitry

OUTPUT

ZipLink Pre-Wired PLC Connection Cables and


Modules for CLICK PLC

0
0
32

10
50

20
68

30
85

40
104

50 55 C
122 131 F

Surrounding Air Temperature (C/F)

11-pin connector cable


ZL-C0-CBL11 (0.5 m length)
ZL-C0-CBL11-1 (1.0 m length)
ZL-C0-CBL11-2 (2.0 m length)

Programmable Controllers

Software
C-more &
other HMI
Drives
Soft
Starters
Motors &
Gearbox
Steppers/
Servos
Motor
Controls
Proximity
Sensors
Photo
Sensors
Limit
Switches
Encoders
Current
Sensors
Pressure
Sensors
Temperature
Sensors
Pushbuttons/
Lights
Process
Relays/
Timers
Comm.
Terminal
Blocks &
Wiring
Power
Circuit
Protection
Enclosures
Tools
Pneumatics

Part #
Index

Volume 13

w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c

Field I/O

Product
Index

1
COM

Programmable
Controllers

Appendix

ZL-RTB20 20-pin
feed-through
connector module

Points

80,000 cycles
80,000 cycles
80,000 cycles
80,000 cycles

* These relay outputs support both inductive (solenoid)


and resistive loads.

Equivalent Output Circuit


24 VDC
240 VAC

Relay Life
(ON to OFF = 1 cycle)

30 VDC, 1A, Resistive


30 VDC, 1A, Solenoid
250 VAC, 1A, Resistive
250 VAC, 1A, Solenoid

Optical Isolator

+
+

Not built into the module - Install protection elements such as external fuse
ADC p/n C0-8TB
3.2 oz (90 g)

Systems
Overview

e1-71

CLICK I/O Module Specifications


C0-04AD-1

<--->

4-Channel Analog Current Input Module

4-channel analog current sinking input module, 13-bit resolution,


range: 0-20 mA. External 24VDC power required, removable terminal
block included. (replacement ADC p/n C0-8TB).

C0-04AD-1 Input Specifications

Wiring Diagram

Inputs per Module


Input Range
Resolution
Input Type
Maximum Continuous Overload
Input Impedance
Filter Charactistics
Sample Duration Time
All Channel Update Rate
Open Circuit Detection Time
Accuracy vs. Temperature

C0-04AD-1

0-20mA

2-wire
4-20mA
Transmitter
4-wire
4-20mA
Transmitter
2-wire
4-20mA
Transmitter

3-wire
4-20mA
Transmitter

Module
Supply

CH1
CH2
CH3
CH4
0V
0V
0V
0V
0V
24V
0V

Connect the unused


channel to 0V terminal.

INPUT

*0.032A fast-acting fuse


(ADC p/n S500-32-R)
is recommended.

Maximum Inaccuracy
All 0V
Linearity Error (End to End)
ter
terminals are
Input Stability and
con
connected
Repeatability
int
internally.

CHn
0V

NOTE: When using this module you must also use CLICK
programming software and CPU firmware version V1.40 or later.

Full Scale Calibration Error


(including Offset)
Offset Calibration Error
Maximum Crosstalk at DC,
50/60 Hz
Field to Logic Side Isolation
Recommended Fuse (external)
External 24 VDC Power
Required
Bus Power Required (24 VDC)
Terminal Block Replacement
Weight

4
0-20 mA (sink)
13-bit, 2.44 uA/count
Single ended (one common)
44 mA
124, 0.5 W current input
Low pass, -3 dB at 120 Hz
2 ms
25 ms
Zero reading within 100 ms
75 PPM/C maximum
0.5% of range (including temperature
changes)
3 count maximum,
monotonic with no missing codes
2 count maximum
8 count maximum
8 count maximum
2 count maximum
1800 VAC for 1 sec.
ADC p/n S500-32-R (0.032A fuse)
65 mA
20 mA
ADC p/n C0-8TB
2.9 oz (82 g)

ZipLink Pre-Wired PLC Connection


Cables and Modules for CLICK PLC

11-pin connector cable


ZL-C0-CBL11 (0.5 m length)
ZL-C0-CBL11-1 (1.0 m length)
ZL-C0-CBL11-2 (2.0 m length)

ZL-RTB20 20-pin feedthrough connector module


Volume 13

e1-72

Programmable Controllers

1 - 80 0 - 633 - 0405

CLICK I/O Module Specifications


C0-04AD-2

Company
Information
Systems
Overview

<--->

Programmable
Controllers

4-Channel Analog Voltage Input Module

Field I/O

4-channel analog voltage input module, 13-bit resolution, range: 0-10V.


External 24VDC power required, removable terminal block included.
(replacement ADC p/n C0-8TB).

Inputs per Module


Input Range
Resolution
Input Type
Maximum Continuous Overload
Input Impedance
Filter Charactistics
Sample Duration Time
All Channel Update Rate
Open Circuit Detection Time
Accuracy vs. Temperature

C0-04AD-2
Voltage
Transmitter

24VDC
Power
Supply

0-10V

INPUT

Voltage
Transmitter

Voltage
Transmitter

C-more &
other HMI
Drives

C0-04AD-2 Input Specifications

Wiring Diagram

Voltage
Transmitter

Software

Maximum Inaccuracy

CH1
CH2
CH3
CH4
0V
0V
0V
0V
0V
24V
0V

Connect the unused


channel to 0V terminal.

Linearity Error (End to End)


All 0V
ter
terminals are Input Stability and
con
connected
Repeatability
int
internally.

CHn

4
0-10 V
13-bit, 1.22 mV per count
Single ended (one common)
100 VDC
>150k
Low pass, -3 dB at 500 Hz
6.25 ms
25 ms
Zero reading within 100 ms
75 PPM/C maximum
0.5% of range (including temperature changes)
3 count maximum,
monotonic with no missing codes
2 count maximum

Full Scale Calibration Error


(Including Offset)
Offset Calibration Error
Maximum Crosstalk at DC,
50/60 Hz
Field to Logic Side Isolation
External 24 VDC Power
Required
Base Power Required (24 VDC)
Terminal Block Replacement
Weight

Motors &
Gearbox
Steppers/
Servos
Motor
Controls
Proximity
Sensors
Photo
Sensors
Limit
Switches
Encoders
Current
Sensors

8 count maximum
8 count maximum

Pressure
Sensors

2 count maximum
1800 VAC for 1 sec.

Temperature
Sensors

65 mA

Pushbuttons/
Lights

23 mA
ADC p/n C0-8TB
2.9 oz (82 g)

Process

0V

NOTE: When using this module you must also use CLICK
programming software and CPU firmware version V1.40 or later.

Soft
Starters

Relays/
Timers

ZipLink Pre-Wired PLC Connection


Cables and Modules for CLICK PLC

Comm.
Terminal
Blocks &
Wiring
Power
Circuit
Protection

11-pin connector cable


ZL-C0-CBL11 (0.5 m length)
ZL-C0-CBL11-1 (1.0 m length)
ZL-C0-CBL11-2 (2.0 m length)

Enclosures
Tools
Pneumatics
Appendix
Product
Index

ZL-RTB20 20-pin feedthrough connector module


Volume 13

w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c

Programmable Controllers

e1-73

Part #
Index

CLICK I/O Module Specifications


C0-04RTD

<--->

C0-04RTD Input Specifications

4-Channel RTD Input Module

4-channel RTD input module, 16-bit resolution (+/-0.1


degrees Celsius or Fahrenheit), supports: Pt100, Pt1000,
JPt100, Cu10, Cu25, Ni120. Resistive ranges also
supported, removable terminal block included. (replacement
ADC p/n C0-16TB).

Inputs per Module


Common Mode Range
Common Mode Rejection
Input Impedance
Maximum Ratings
Resolution
Input Ranges*

4
2.5 V
100 dB at DC and 100 dB at 50/60 Hz
>5 M
Fault protected inputs to 50 VDC
0.1C or F, 0.1 or 0.01
Pt100: -200 to 850C (-328 to 1562F)
Pt1000: -200 to 595C (-328 to 1103F)
JPt100: -100 to 450C (-148 to 842F)
10 Cu: -200 to 260C (-328 to 500F)
25 Cu: -200 to 260C (-328 to 500F)
120 Ni: -80 to 260C (-112 to 500F)
0 to 3125.0 : Resolution 0.1
0 to 1562.5 : Resolution 0.1
0 to 781.2 : Resolution 0.1
0 to 390.62 : Resolution 0.01
0 to 195.31 : Resolution 0.01

RTD Linearization
Excitation Current (All Ranges)
Accuracy vs. Temperature
RTD Input Maximum
Inaccuracy
RTD Linearity Error
(End to End)
Resistance Input Maximum
Zero Scale Error
Resistance Input Maximum
Full Scale Error

Automatic
210 A
10 ppm per C maximum

Maximum Linearity Error

0.015% of full scale range maximum at


25C, monotonic with no missing codes

Resistance Maximum Input


Inaccuracy
Warm Up Time
Sample Duration Time

0.1% at 0 to 60C (32 to 140 F), typical


0.04% at 25C (77 F)

NOTE: The C0-04RTD module cannot be used with thermistors.

Wiring Diagram

C0-04RTD

Pt, Cu, Ni, RES

INPUT

COM
R1+
R1
R1C
COM
COM
R2+
R2
R2C
COM
COM
R3+
R3
R3C
COM
COM
R4+
R4
R4C
COM

Connect
unused
channels

Rn+

All Channel Update Rate

These COM terminals


are isolated.

RnRnC

NOTE: When using this module you must also use CLICK
programming software and CPU firmware version
V1.40 or later.
NOTE: When this module is used in a CLICK PLC system, it may take up to 24 seconds for initialization after
power-up (see the table below). During this time
period, the RUN LED on the CPU module blinks to
indicate the initialization process.

C0-04RTD Initialization Time


The Number of The same Input Type is Mixed Input Types
Channels Used selected for all Channels
are selected
1
2
3
4

4 sec
5 sec
6 sec
7 sec

Open Circuit Detection Time


Conversion Method

3C (excluding RTD error);


5C (ranges Cu10 and Cu25)
2C maximum, 0.5C typical, monotonic
with no missing codes
0.0015% of full scale range in ohms
(negligible)
0.02% of full scale range

30 minutes for 1C repeatability


240 ms
Single Channel Update Rate times the number of enabled channels on the module
Positive full-scale reading within 2 seconds
Sigma - Delta

* While it is possible to use different resistive ranges, we recommend using the


narrowest range that covers the resistance being measured. For example, if
measuring approximately 100 ohms resistance, use the 0 to 195.31ohms
range. While the resolution is the same as the 0 to 390.62 ohms range,
output RMS noise will be lower and stability will be improved.

C0-04RTD General Specifications


Field to Logic Side Isolation
External DC Power Required
Bus Power Required (24 VDC)
Thermal Dissipation
Terminal Block Replacement
Weight

No isolation
None
25 mA
2.047 BTU per hour
ADC p/n C0-16TB
3.1 oz (86 g)

Not Compatible with ZipLink


Pre-Wired PLC Connection
Cables and Modules.

N/A
May take up to 13 sec
May take up to 18 sec
May take up to 24 sec

Volume 13

e1-74

Programmable Controllers

1 - 80 0 - 633 - 0405

CLICK I/O Module Specifications


C0-04THM

<--->

Inputs per Module


Common Mode Range
Common Mode Rejection
4-channel thermocouple input module, 16-bit resolution (+/-0.1
Input Impedance
degrees Celsius or Fahrenheit), Supports: J, K, E, R, S, T, B, N, C type
Maximum Ratings
thermocouples; voltage ranges are also supported, removable
Resolution
terminal block included. (replacement ADC p/n C0-8TB).
Input Ranges
C0-04THM

J,K,E,R,S,T,B,N,C,mV

INPUT

Connect
unused
channels

TCn+
TCnCOM

Shield

Device
Power
Supply

mV
Device

mV
Device

COM
TC1+
TC1
TC2+
TC2
COM
TC3+
TC3
TC4+
TC4
COM

Systems
Overview
Programmable
Controllers

C0-04THM Input Specifications

4-Channel Thermocouple Input Module

Wiring Diagram

Company
Information

All COM
ter
terminals are
con
connected
int
internally.

Cold Junction Compensation


Thermocouple Linearization
Accuracy vs. Temperature
Linearity Error
Maximum Inaccuracy
Maximum Voltage Input Offset
Error
Maximum Voltage Input Gain
Error
Maximum Voltage Input
Linearity Error
Maximum Voltage Input
Inaccurracy
Warm Up Time
Sample Duration Time

*Cannot exceed common-mode

NOTE: When using this module you must also use CLICK
programming software and CPU firmware version
V1.40 or later.

All Channel Update Rate

NOTE: With grounded thermocouples, take precautions


to prevent having a voltage potential between thermocouple tips. A voltage less than -1.3V or greater than
+3.8V between tips will skew measurements.

Open Circuit Detection Time


Conversion Method

4
-1.3 to +3.8 V
100 dB at DC and 130 dB at 60 Hz
>5 M
Fault protected inputs to 50 VDC
0.1C or F, 16 bit
Type J: -190 to 760C (-310 to 1400F)
Type K: -150 to 1372C (-238 to 2502F)
Type E: -210 to 1000C (-346 to 1832F)
Type R: 65 to 1768C (149 to 3214F)
Type S: 65 to 1768C (149 to 3214F)
Type T: -230 to 400C (-382 to 752F)
Type B: 529 to 1820C (984 to 3308F)
Type N: -70 to 1300C (-94 to 2372F)
Type C: 65 to 2320C (149 to 4208F)
0 to 39.0625 mV
39.0625 mV
78.125 mV
0 to 156.25 mV
156.25 mV
0 to 1.25 V
Automatic
Automatic
25 ppm per C maximum
2C maximum, 1C typical, monotonic
with no missing codes
3C maximum (excluding thermocouple
error)
0.05% at 0 to 55 C (32 to 131 F), typical 0.04% at 25 C (77 F)
0.06% at 25C (77F)
0.05% at 0 to 55C (32 to 131F), typical
0.03% at 25C (77F)
0.1% at 0 to 55C (32 to 131F), typical
0.04% at 25C (77F)
30 minutes for 1C repeatability
400 ms
Single Channel Update Rate times the number of enabled channels on the module
Burn Out flag set and zero scale reading
within 3 seconds
Sigma - Delta

C0-04THM General Specifications


Field to Logic Side Isolation
External DC Power Required
Bus Power Required (24 VDC)
Thermal Dissipation
Terminal Block Replacement
Weight

C0-04THM Initialization Time

NOTE: When this module is used in a CLICK


The Number of
PLC system, it takes up to 11 seconds for
Channels Used
initialization after power-up (see the table right).
1
During this time period, the RUN LED on the
2
CPU module blinks to indicate the initialization
3
process.
4

1800 VAC applied for 1 second (100%


tested)
None
25 mA
0.175 BTU per hour
ADC p/n C0-8TB
3.1 oz (86 g)

Not Compatible with ZipLink Pre-Wired PLC


Connection Cables and Modules.

Software
C-more &
other HMI
Drives
Soft
Starters
Motors &
Gearbox
Steppers/
Servos
Motor
Controls
Proximity
Sensors
Photo
Sensors
Limit
Switches
Encoders
Current
Sensors
Pressure
Sensors
Temperature
Sensors
Pushbuttons/
Lights
Process
Relays/
Timers
Comm.
Terminal
Blocks &
Wiring
Power
Circuit
Protection
Enclosures
Tools
Pneumatics
Appendix

With any
Configuration

Product
Index

5 sec
7 sec
9 sec
11 sec

Part #
Index

Volume 13

w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c

Field I/O

Programmable Controllers

e1-75

CLICK I/O Module Specifications


C0-04DA-1

<--->

4-Channel Analog Current Output Module

4-channel analog current sourcing output module, 12-bit resolution,


range: 4-20 mA. External 24VDC power required, removable
terminal block included. (replacement ADC p/n C0-8TB).

Wiring Diagram

4-20mA

OUTPUT

Ch2
Load
Ch3
Load
Ch4
Load

24VDC +
Power
Supply

4
4-20 mA (source)
12-bit, 3.9 uA per count
Current sourcing at 20 mA max. (one

Output Type
C0-04DA-1

Ch1
Load

C0-04DA-1 Output Specifications


Outputs per Module
Output Range
Resolution

CH1
CH2
CH3
CH4
0V
0V
0V
0V
0V
24V
0V

All 0V
terminals are
connected
internally.

NOTE: When using this module you must also use CLICK
programming software and CPU firmware version V1.40 or later.

common)

Output Value in Fault Mode

Less than 4mA

Load Impedance

0-600 at 24 VDC; minimum load: 0


32 to 131F (0 to 55C) ambient temp.

Maximum Inductive Load


Allowed Load Type
Maximum Inaccuracy
Max. Full Scale Calibration
Error (Including Offset)
Max. Offset Calibration Error

1 mH
Grounded
1% of range

Accuracy vs. Temperature

75 PPM/C maximum full scale calibration change (0.005% of range/C)

Max. Crosstalk at DC, 50/60 Hz


Linearity Error (End to End)
Output Stability and
Repeatability
Output Ripple

-72 dB, 1 LSB


4 LSB max., (0.1% of full scale)

0.2% of range maximum


0.2% of range maximum

2% LSB after 10 minute warmup period


typical

Field to Logic Side Isolation

0.1% of full scale


0.3 ms maximum, 5 s min. (full scale
range)
10 ms
Outputs open circuit protected
1800 VAC applied for 1 second (100%
tested)

Type of Output Protection

Electronically limited to 20 mA or less

Output Settling Time


All Channel Update Rate
Max. Continuous Overload

Output Signal at Power Up and


Power Down
External VDC Power Required
Base Power Required (24 VDC)
Terminal Block Replacement
Weight

4 mA
145 mA
20 mA
ADC p/n C0-8TB
2.9 oz (82 g)

ZipLink Pre-Wired PLC Connection


Cables and Modules for CLICK PLC

11-pin connector cable


ZL-C0-CBL11 (0.5 m length)
ZL-C0-CBL11-1 (1.0 m length)
ZL-C0-CBL11-2 (2.0 m length)

ZL-RTB20 20-pin feedthrough connector module


Volume 13

e1-76

Programmable Controllers

1 - 80 0 - 633 - 0405

CLICK I/O Module Specifications


C0-04DA-2

<--->

4-channel analog voltage output module, 12-bit resolution, range:


0-10V. External 24VDC power required, removable terminal block
included. (replacement ADC p/n C0-8TB).

C0-04DA-2 Output Specifications


Outputs per Module
Output Range
Resolution
Output Type

C0-04DA-2

0-10V

OUTPUT

Accuracy vs. Temperature


Max. Crosstalk at DC, 50/60 Hz

Ch2
Load

Linearity Error (End to End)

Ch4
Load

24VDC +
Power
Supply

CH1
CH2
CH3
CH4
0V
0V
0V
0V
0V
24V
0V

4
0-10 V
12-bit, 2.44 mV per count
Voltage sourcing at 10mA max. (one
common)
Determined by CPU
0V
0.2 typical
>1000
0.01 uF maximum
Grounded
0.5% of range

Output Value in Program Mode


Output Value in Fault Mode
Output Impedance
Load Impedance
Maximum Capacitive Load
Allowed Load Type
Maximum Inaccuracy
Max. Full Scale Calibration
0.2% of range maximum voltage
Error (Not including Offset)
0.2% of range maximum
Max. Offset Calibration Error

Wiring Diagram

Ch3
Load

Systems
Overview
Programmable
Controllers

4-Channel Analog Voltage Output Module

Ch1
Load

Company
Information

All 0V
terminals are
connected
internally.

NOTE: When using this module you must also use CLICK
programming software and CPU firmware version V1.40 or later.

Output Stability and


Repeatability
Output Ripple
Output Settling Time
All Channel Update Rate
Max. Continuous Overload
Field to Logic Side Isolation
Type of Output Protection
Output Signal at Power Up and
Power Down
External 24 VDC Power
Required
Base Power Required (24 VDC)
Terminal Block Replacement
Weight

75 PPM/C maximum full scale calibration change (0.0025% of range/C)


-72 dB, 1 LSB
4 LSB max., (0.1% of full scale);
monotonic with no missing codes
2% LSB after 10 minute warmup period
typical
0.1% of full scale
0.3 ms maximum, 5 s minimum (full
scale range)
10 ms
Outputs current limited to 40 mA typical;
continuous overloads on multiple outputs
can damage module.
1800 VAC applied for 1 second (100%
tested)
0.1 F transient suppressor

Field I/O
Software
C-more &
other HMI
Drives
Soft
Starters
Motors &
Gearbox
Steppers/
Servos
Motor
Controls
Proximity
Sensors
Photo
Sensors
Limit
Switches
Encoders
Current
Sensors
Pressure
Sensors
Temperature
Sensors

0V

Pushbuttons/
Lights

85 mA

Process
Relays/
Timers

20 mA
ADC p/n C0-8TB
2.9 oz (82 g)

Comm.

ZipLink Pre-Wired PLC Connection


Cables and Modules for CLICK PLC

Terminal
Blocks &
Wiring
Power
Circuit
Protection
Enclosures

11-pin connector cable


ZL-C0-CBL11 (0.5 m length)
ZL-C0-CBL11-1 (1.0 m length)
ZL-C0-CBL11-2 (2.0 m length)

Tools
Pneumatics
Appendix
Product
Index
Part #
Index

ZL-RTB20 20-pin feedthrough connector module


Volume 13

w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c

Programmable Controllers

e1-77

CLICK I/O Module Specifications


C0-4AD2DA-1

<--->

C0-4AD2DA-1 Input Specifications

4-Channel Analog Current Input and


2-Channel Analog Current Output Module

4-channel analog current sinking input (13-bit resolution) and


2-channel analog current sourcing output (12-bit resolution) module,
range: 0-20 mA (inputs), 4-20 mA (outputs). External 24VDC power
required, removable terminal block included. (replacement ADC p/n
C0-16TB).
Wiring Diagram

*0.032A fast-acting fuse


(ADC p/n S500-32-R)
is recommended.

2-wire
+
4-20mA

Transmitter

C0-4AD2DA-1

*
N.C.

N.C.
2-wire
+
4-20mA

Transmitter
+
3-wire

4-20mA
Transmitter +

N.C.
N.C.

Load
+
24VDC
Power
Supply

N.C.

N.C.
N.C. =
Not Connected

CH1
0V

All 0V
termin
terminals are
con
connected
intern
internally.

CH2
0V
CH3
0V
CH4
0V
CH1
0V

OUTPUT

Load

0-20mA In
4-20mA Out

0V

INPUT

+
4-wire

4-20mA
Transmitter

Connect the unused input


channel to 0V terminal.

CHn

CH2
0V
24V
0V

PLC Data Format

16-bit unsigned Integer, range is 0-8191

Sample Duration Time

5 ms

All Channel Update Rate

20 ms (input plus output maximum time)

Open Circuit Detection Time


Conversion Method
Accuracy vs. Temperature

Zero reading within 20 ms


Successive approximation
75 PPM/C maximum
0.5% of range (including temperature
changes)
3 count maximum,
monotonic with no missing codes

Maximum Inaccuracy
Linearity Error (End to End)
Input Stability and
Repeatability
Full Scale Calibration Error
(Including Offset)
Offset Calibration Error
Maximum Crosstalk at DC,
50/60 Hz

2 count maximum
8 count maximum
8 count maximum
2 count maximum

C0-4AD2DA-1 Output Specifications


Outputs per Module
Output Range
Resolution

2
4-20 mA (source)
12-bit, 3.9 uA per count
Current sourcing at 20 mA max. (one
common)
12-bit unsigned integer, 0-4095 counts
Less than 4 mA

Output Type
PLC Data Format
Output Value in Fault Mode

0-600 at 24 VDC; minimum load: 0


32 to 113F (0 to 45C); 125 113 to
131F (45 to 55C) ambient temp.

Load Impedance

1800 VAC for 1 sec.


75 mA

Accuracy vs. Temperature

25 mA
ADC p/n S500-32-R (0.032A fuse)
ADC p/n C0-16TB
3.1 oz (86 g)

Max. Crosstalk at DC, 50/60 Hz

C0-4AD2DA-1 General Specifications

ZipLink Pre-Wired PLC Connection


Cables and Modules for CLICK PLC

ZL-RTB20 20-pin feedthrough connector module

4
0-20 mA (sink)
13-bit, 2.44 uA per count
Single ended (one common)
44 mA
124, 0.5 W current input
Low pass, -3 dB at 400 Hz

Maximum Inductive Load


Allowed Load Type
Maximum Inaccuracy
Max. Full Scale Calibration
Error (Including Offset)
Max. Offset Calibration Error

NOTE: When using this module you must also use CLICK
programming software and CPU firmware version V1.40 or later.

Field to Logic Side Isolation


External 24 VDC Power
Required
Bus Power Required (24 VDC)
Recommended Fuse (External)
Terminal Block Replacement
Weight

Inputs per Module


Input Range
Resolution
Input Type
Maximum Continuous Overload
Input Impedance
Filter Charactistics

20-pin connector cable


ZL-C0-CBL20 (0.5 m length)
ZL-C0-CBL20-1 (1.0 m length)
ZL-C0-CBL20-2 (2.0 m length)

Linearity Error (End to End)


Output Stability and
Repeatability
Output Ripple
Output Settling Time
All Channel Update Rate
Max. Continuous Overload
Type of Output Protection
Output Signal at Power Up or
Power Down

1 mH
Grounded
1% of range
0.2% of range maximum
0.2% of range maximum
50 PPM/C maximum full scale calibration change (0.005% of range/C)
-72 dB, 1 LSB
4 LSB maximum, (0.1% of full scale),
monotonic with no missing codes
2% LSB after 10 minute warmup period
typical
0.1% of full scale
0.2 ms maximum, 5 s min. (full scale
range)
20 ms
Outputs open circuit protected
Electronically limited to 20 mA or less
4 mA

Volume 13

e1-78

Programmable Controllers

1 - 80 0 - 633 - 0405

CLICK I/O Module Specifications


C0-4AD2DA-2

<--->

+
Voltage
Transmitter
+
Voltage
Transmitter

CH1
0V
CH2
0V

N.C.

CH3
0V

N.C.

CH4
0V

N.C.
Ch1
Load
Ch2
Load
+

CH1
0V

N.C.

OUTPUT

24VDC
Power
Supply

con
connected
internally.
int

INPUT

+
Voltage
Transmitter

C0-4AD2DA-2 Input Specifications

0-10V

N.C.

CH2
0V

N.C.

24V
0V

N.C. = Not Connected

NOTE: When using this module you must also use CLICK
programming software and CPU firmware version V1.40 or later.

C0-4AD2DA-2 General Specifications


Field to Logic Side Isolation
External 24 VDC Power
Required
Base Power Required (24 VDC)
Terminal Block Replacement
Weight

1800 VAC

Maximum Inaccuracy
Linearity Error (End to End)
Input Stability and
Repeatability
Full Scale Calibration Error
(including Offset)
Offset Calibration Error
Maximum Crosstalk at DC,
50/60 Hz

15 mA
ADC p/n C0-16TB
3.1 oz (86 g)

Outputs per Module


Output Range
Resolution
Output Type

8 count maximum

2
0-10 V
12-bit, 2.44 mV per count
Voltage sourcing at 10mA max. (one

Accuracy vs. Temperature

75 PPM/C maximum full scale calibration change (0.0025% of range/C)

Motors &
Gearbox
Steppers/
Servos
Motor
Controls

Encoders
Current
Sensors
Pressure
Sensors
Temperature
Sensors

Relays/
Timers

0.2% of range maximum voltage


0.2% of range maximum

Comm.
Terminal
Blocks &
Wiring
Power

Linearity Error (End to End)

4 LSB maximum, (0.1% of full scale);


monotonic with no missing codes

Output Stability and


Repeatability
Output Ripple

2% LSB after 10 minute warmup period


typical
0.5% of full scale
0.3 ms maximum, 5 s minimum (full
scale range)
20 ms
Outputs current limited to 40 mA typical;
continuous overloads on multiple outputs
can damage module.
0.1 F transient suppressor

Circuit
Protection
Enclosures
Tools
Pneumatics
Appendix
Product
Index
Part #
Index

0V

Programmable Controllers

Soft
Starters

Process

Volume 13

w w w. a u to m a t i o n d i re c t . c o m / c l i c k- p l c

Drives

Pushbuttons/
Lights

Max. Crosstalk at DC, 50/60 Hz -72 dB, 1 LSB

Type of Output Protection


Output Signal at Power Up or
Power Down

C-more &
other HMI

Limit
Switches

2 count maximum

common)

Max. Continuous Overload

Software

Photo
Sensors

8 count maximum

Determined by CPU
0V
0.2 typical
>1000
0.01 uF maximum
Grounded
1% of range

Output Settling Time

Field I/O

Proximity
Sensors

2 count maximum

Output Value in Program Mode


Output Value in Fault Mode
Output Impedance
Load Impedance
Maximum Capacitive Load
Allowed Load Type
Maximum Inaccuracy
Max. Full Scale Calibration
Error (Not including Offset)
Max. Offset Calibration Error

All Channel Update Rate

20-pin connector cable


ZL-C0-CBL20 (0.5 m length)
ZL-C0-CBL20-1 (1.0 m length)
ZL-C0-CBL20-2 (2.0 m length)

4
0-10 V
13-bit, 1.22 mV per count
Single ended (one common)
100 VDC
>150 k
Low pass, -3 dB at 500 Hz
5 ms
20 ms
Zero reading within 100 ms
Successive approximation
75 PPM/C maximum
0.5% of range (including temperature
changes)
3 count maximum,
monotonic with no missing codes

C0-4AD2DA-2 Output Specifications

65 mA

ZipLink Pre-Wired PLC Connection


Cables and Modules for CLICK PLC

ZL-RTB20 20-pin feedthrough connector module

Systems
Overview
Programmable
Controllers

Inputs per Module


4-Channel Analog Voltage Input and
Input Range
2-Channel Analog Voltage Output Module
Resolution
4-channel analog voltage input (13-bit resolution) and 2-channel Input Type
analog voltage output (12-bit resolution) module, range: 0-10V. Maximum Continuous Overload
External 24VDC power required, removable terminal block included. Input Impedance
(replacement ADC p/n C0-16TB).
Filter Charactistics
Sample Duration Time
All Channel Update Rate
Wiring Diagram
Open Circuit Detection Time
CHn
Connect the unused input
Conversion Method
channel to 0V terminal.
C0-4AD2DA-2 All 0V
0V
Accuracy vs. Temperature
ter
terminals are
+
Voltage
Transmitter

Company
Information

e1-79

Accessories

C0-USER-M

<--->

CLICK PLC Hardware User


Manual

Manual covers all CLICK CPU and I/O


module installation and wiring, specifications, error codes and trouble shooting
guide. Sold separately from hardware.

The CLICK PLC Hardware User Manual


can be downloaded free at the
AutomationDirect Web site, or purchased
from the AutomationDirect online Web
store. www.automationdirect.com

D2-DSCBL

Programming Cable for CLICK


and DirectLOGIC PLCs

12 ft. (3.66m) RS232 shielded PC


programming cable for CLICK, DL05,
DL06, DL105, DL205, D3-350, and D4450 CPUs. 9-pin D-shell female connector
to an RJ12 6P6C connector.
Note: If your PC has a USB port but does
not have a serial port, you must use
programming cable EA-MG-PGM-CBL.

C0-3TB
C0-PGMSW

<--->

Programming Software CD-ROM

EA-MG-PGM-CBL

<--->

PC to Panel Programming Cable


Assembly for C-more MicroGraphic Panels and CLICK PLCs

6-ft. cable assembly to connect a personal


computer to any C-more Micro-Graphic
panel or CLICK PLC for setup and
programming.
Note: This cable assembly uses the PC's USB port and
converts the signals to serial transmissions. The USB
port supplies 5 VDC to the Micro-Graphic panel for
configuration operations.

Assembly includes standard USB A-type


connector to B-type connector cable,
custom converter, and a RS232C cable
with RJ12 modular connector on each end.

C0-16TB

<--->

Spare 16-Point I/O Terminal


Block

Replacement terminal block for the


16-point I/O modules and CPU built-in
I/O. Sold in packs of 2.

DN-SS1

<--->

DN-WS

<--->

DN-EB35MN

<--->

Insulated Slotted Screwdriver


0.4 x 2.5 x 75 mm

<--->

Spare 3-Pole Terminal Block

Replacement 3-pole terminal block for the


3-wire RS-485 Port 3 on CLICK Standard
and Analog CPUs. Sold in packs of 2.

C0-4TB

The programming software can be downloaded free at the AutomationDirect Web


site,
or
purchased
from
the
Automatio nD irect online Web store.
www.automationdirect.com

<--->

<--->

Spare 24 VDC Power Terminal


Block

Replacement terminal block for the 24


VDC supply power to the CPU. Sold in
packs of 2.

C0-8TB

<--->

Wire Stripper

DINnectors End Bracket

Spare 8-Point I/O Terminal Block

C-more and C-more Micro


Graphic Operator Interfaces

D2-BAT-1

ZIPLink Wiring Systems

Replacement terminal block for the 8-point


I/O modules. Sold in packs of 2.

<--->

Replacement battery for Standard and


Analog CPU modules.

Volume 13

e1-80

Programmable Controllers

1 - 80 0 - 633 - 0405

S-ar putea să vă placă și