Documente Academic
Documente Profesional
Documente Cultură
ZTE CORPORATION
NO. 55, Hi-tech Road South, ShenZhen, P.R.China
Postcode: 518057
Tel: +86-755-26771900
Fax: +86-755-26770801
URL: http://ensupport.zte.com.cn
E-mail: support@zte.com.cn
LEGAL INFORMATION
Copyright 2011 ZTE CORPORATION.
The contents of this document are protected by copyright laws and international treaties. Any reproduction or
distribution of this document or any portion of this document, in any form by any means, without the prior written
consent of ZTE CORPORATION is prohibited.
Revision History
Revision No.
Revision Date
Revision Reason
R1.0
20100506
First Edition(V4.09.21.01)
R2.0
20100714
Second Edition(V4.09.21.02)
R3.0
20100805
Third Edition(V4.09.21.03)
R3.1
20100901
Cell
counters
C370810000,
C370810001,
C370810002,
20101108
Fourth Edition(V4.09.21.05)
It have been updated due to version upgrade.
R5.0
20110104
Fifth Edition(V4.09.21.08)
Modify counter C372420000.
Add
counters
C372420001,
C372420002,
C372420003
Contents
Preface............................................................................................................. I
Chapter 1 CELL Ant Balance Measurement............................................. 1-1
1.1 Measurement Flow of Cell Antenna Balancing Times............................................ 1-1
1.2 C372410000 Balance times of antenna 1............................................................. 1-3
1.3 C372410001 Balance times of antenna 2............................................................. 1-4
1.4 C372410002 Balance times of antenna 3............................................................. 1-5
1.5 C372410003 Balance times of antenna 4............................................................. 1-6
1.6 C372410004 Balance times of antenna 5............................................................. 1-7
1.7 C372410005 Balance times of antenna 6............................................................. 1-8
8.2 Measurement Flow of Hardwares Maximum Transmission Power Counter ............ 8-4
8.3 Measurement Flow of Cells Maximum Transmission Power.................................. 8-4
8.4 Measurement Flow of Hardwares Maximum UL/DL Available CE Quantity ............ 8-5
8.5 Measurement Flow of Propagation Delay............................................................. 8-6
8.6 C372480000 Number of transmitting antennas..................................................... 8-7
8.7 C372480001 Maximum TSSI of antenna 1 ........................................................... 8-8
8.8 C372480002 minimum TSSI of antenna 1 ........................................................... 8-9
8.9 C372480003 Average TSSI of antenna 1 .......................................................... 8-10
8.10 C372480004 Maximum TSSI of antenna 2 ........................................................8-11
8.11 C372480005 minimum TSSI of antenna 2 ....................................................... 8-12
8.12 C372480006 Average TSSI of antenna 2 ........................................................ 8-12
8.13 C372480007 Maximum TSSI of antenna 3 ....................................................... 8-13
8.14 C372480008 minimum TSSI of antenna 3 ....................................................... 8-14
8.15 C372480009 Average TSSI of antenna 3 ........................................................ 8-15
8.16 C372480010 Maximum TSSI of antenna 4 ....................................................... 8-16
8.17 C372480011 minimum TSSI of antenna 4 ....................................................... 8-17
8.18 C372480012 Average TSSI of antenna 4 ........................................................ 8-17
8.19 C372480013 Maximum TSSI of antenna 5 ....................................................... 8-18
8.20 C372480014 minimum TSSI of antenna 5 ....................................................... 8-19
8.21 C372480015 Average TSSI of antenna 5 ........................................................ 8-20
8.22 C372480016 Maximum TSSI of antenna 6 ....................................................... 8-21
8.23 C372480017 minimum TSSI of antenna 6 ....................................................... 8-22
8.24 C372480018 Average TSSI of antenna 6 ........................................................ 8-22
8.25 C372480019 Maximum TSSI of antenna 7 ....................................................... 8-23
8.26 C372480020 minimum TSSI of antenna 7 ....................................................... 8-24
8.27 C372480021 Average TSSI of antenna 7 ........................................................ 8-25
8.28 C372480022 Maximum TSSI of antenna 8 ....................................................... 8-26
8.29 C372480023 minimum TSSI of antenna 8 ....................................................... 8-27
8.30 C372480024 Average TSSI of antenna 8 ........................................................ 8-27
8.31 C372480025 Maximum TSSI of antenna 9 ....................................................... 8-28
8.32 C372480026 minimum TSSI of antenna 9 ....................................................... 8-29
8.33 C372480027 Average TSSI of antenna 9 ........................................................ 8-30
8.34 C372480028 Maximum TSSI of antenna 10 ..................................................... 8-31
8.35 C372480029 minimum TSSI of antenna 10 ..................................................... 8-32
8.36 C372480030 Average TSSI of antenna 10 ...................................................... 8-32
8.37 C372480031 Maximum TSSI of antenna 11 ..................................................... 8-33
8.38 C372480032 minimum TSSI of antenna 11 ...................................................... 8-34
IV
VI
VII
VIII
IX
XI
XII
Glossary .......................................................................................................... I
XIII
XIV
Preface
About This Manual
As a mobile network element management system between lower-layer network
management system and upper-layer operation support system, NetNumen M31
enables users to control the network as a whole and provides centralized network
management for operators. Through interfaces of various network management systems,
it changes previously decentralized network management to centralized network topology,
alarm, and performance management. Additionally, it provides necessary interfaces to
upper-layer application systems.
This manual introduces the counters used to measure the performance of the SDR base
stations developed by ZTE Corporation for the third-generation mobile communication.
Summary
Measurement
performance measurement.
Measurement
performance measurement.
Chapter
Summary
Measurement
Intended Audience
l
l
l
II
Chapter 1
1-1
SJ-20100510160815-008|2011-01-04(R5.0)
Figure 1-1 The Flow Chart of Cell Antenna Balancing Times Measurement
l
l
1-2
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Ant_1_Balance_Measure
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
CELL Ant
Sampling Point
This counter is udated when the receiving power of antenna 1 is normal.
Description
In a sampling period, if the uplink receiving power of antenna 1 is not significantly different
from that of other antennas in the cell, the counters corresponding to all antennas increase
by 1. In a sampling period, if the uplink receiving power of antenna 1 is much stronger than
that of other antennas in the cell, only the counter corresponding to antenna 1 increases
by 1. The threshold in the measurement request is used as a standard to decide whether
the difference is significant. In a sampling period, if the times of balances of an antenna
is much less than those of other antennas, there may be something wrong with the uplink
search of the antenna.
Updates
When the uplink receiving power of antenna 1 is much stronger than that of other antennas
in the cell, only the counter corresponding to antenna 1 increases by 1. When the uplink
receiving power of antenna 1 is not significantly different from that of other antennas in the
cell, the counters corresponding to all antennas increase by 1.
1-3
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Ant_2_Balance_Measure
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
CELL Ant
Sampling Point
This counter is udated when the receiving power of antenna 2 is normal.
Description
In a sampling period, if the uplink receiving power of antenna 2 is not significantly different
from that of other antennas in the cell, the counters corresponding to all antennas increase
by 1. In a sampling period, if the uplink receiving power of antenna 2 is much stronger than
that of other antennas in the cell, only the counter corresponding to antenna 2 increases
by 1. The threshold in the measurement request is used as a standard to decide whether
the difference is significant. In a sampling period, if the times of balances of an antenna
is much less than those of other antennas, there may be something wrong with the uplink
search of the antenna.
Updates
When the uplink receiving power of antenna 2 is much stronger than that of other antennas
in the cell, only the counter corresponding to antenna 2 increases by 1. When the uplink
receiving power of antenna 2 is not significantly different from that of other antennas in the
cell, the counters corresponding to all antennas increase by 1.
1-4
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Ant_3_Balance_Measure
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
CELL Ant
Sampling Point
This counter is udated when the receiving power of antenna 3 is normal.
Description
In a sampling period, if the uplink receiving power of antenna 3 is not significantly different
from that of other antennas in the cell, the counters corresponding to all antennas increase
by 1. In a sampling period, if the uplink receiving power of antenna 3 is much stronger than
that of other antennas in the cell, only the counter corresponding to antenna 3 increases
by 1. The threshold in the measurement request is used as a standard to decide whether
the difference is significant. In a sampling period, if the times of balances of an antenna
is much less than those of other antennas, there may be something wrong with the uplink
search of the antenna.
Updates
When the uplink receiving power of antenna 3 is much stronger than that of other antennas
in the cell, only the counter corresponding to antenna 3 increases by 1. When the uplink
receiving power of antenna 3 is not significantly different from that of other antennas in the
cell, the counters corresponding to all antennas increase by 1.
1-5
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Ant_4_Balance_Measure
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
CELL Ant
Sampling Point
This counter is udated when the receiving power of antenna 4 is normal.
Description
In a sampling period, if the uplink receiving power of antenna 4 is not significantly different
from that of other antennas in the cell, the counters corresponding to all antennas increase
by 1. In a sampling period, if the uplink receiving power of antenna 4 is much stronger than
that of other antennas in the cell, only the counter corresponding to antenna 4 increases
by 1. The threshold in the measurement request is used as a standard to decide whether
the difference is significant. In a sampling period, if the times of balances of an antenna
is much less than those of other antennas, there may be something wrong with the uplink
search of the antenna.
Updates
When the uplink receiving power of antenna 4 is much stronger than that of other antennas
in the cell, only the counter corresponding to antenna 4 increases by 1. When the uplink
receiving power of antenna 4 is not significantly different from that of other antennas in the
cell, the counters corresponding to all antennas increase by 1.
1-6
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Ant_5_Balance_Measure
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
CELL Ant
Sampling Point
This counter is udated when the receiving power of antenna 5 is normal.
Description
In a sampling period, if the uplink receiving power of antenna 5 is not significantly different
from that of other antennas in the cell, the counters corresponding to all antennas increase
by 1. In a sampling period, if the uplink receiving power of antenna 5 is much stronger than
that of other antennas in the cell, only the counter corresponding to antenna 5 increases
by 1. The threshold in the measurement request is used as a standard to decide whether
the difference is significant. In a sampling period, if the times of balances of an antenna
is much less than those of other antennas, there may be something wrong with the uplink
search of the antenna.
Updates
When the uplink receiving power of antenna 5 is much stronger than that of other antennas
in the cell, only the counter corresponding to antenna 5 increases by 1. When the uplink
receiving power of antenna 5 is not significantly different from that of other antennas in the
cell, the counters corresponding to all antennas increase by 1.
1-7
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Ant_6_Balance_Measure
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
CELL Ant
Sampling Point
This counter is udated when the receiving power of antenna 6 is normal.
Description
In a sampling period, if the uplink receiving power of antenna 6 is not significantly different
from that of other antennas in the cell, the counters corresponding to all antennas increase
by 1. In a sampling period, if the uplink receiving power of antenna 6 is much stronger than
that of other antennas in the cell, only the counter corresponding to antenna 6 increases
by 1. The threshold in the measurement request is used as a standard to decide whether
the difference is significant. In a sampling period, if the times of balances of an antenna
is much less than those of other antennas, there may be something wrong with the uplink
search of the antenna.
Updates
When the uplink receiving power of antenna 6 is much stronger than that of other antennas
in the cell, only the counter corresponding to antenna 6 increases by 1. When the uplink
receiving power of antenna 6 is not significantly different from that of other antennas in the
cell, the counters corresponding to all antennas increase by 1.
1-8
SJ-20100510160815-008|2011-01-04(R5.0)
Chapter 2
VSWR Measurement
Table of Contents
C372420000 VSWR of Transmission Channel 1.........................................................2-1
C372420001 VSWR of Transmission Channel 2.........................................................2-2
C372420002 VSWR of Transmission Channel 3.........................................................2-3
C372420003 VSWR of Transmission Channel 4.........................................................2-4
C372420004 VSWR of Transmission Channel 5.........................................................2-4
C372420005 VSWR of Transmission Channel 6.........................................................2-5
Short Form
VSWR_1
Sampling Period
15 minutes
Counter Type
Maximum Value
Unit
times
Measurement Object
Board
Sampling Point
This counter is udated when the intermediate frequency FPGA in the RRU boards detects
the forward and backward feedback signal energy coupled from the antenna port.
2-1
SJ-20100510160815-008|2011-01-04(R5.0)
Description
With a period of 10 ms, the RRU FPGA detects the transmitting power and reflecting power
coupled from a antenna port and calculates the standing wave of the antenna port based
on a formula. he BSP averages the values once per ten times of readings (in 100 ms) from
the FPGA and reports the average value as the current VSWR.
Updates
The FPGA samples once every 10 ms and averages the values once per 10 samplings,
that is, the counter will be updated every 100 ms.
Short Form
VSWR_2
Sampling Period
15 minutes
Counter Type
Maximum Value
Unit
times
Measurement Object
Board
Sampling Point
This counter is udated when the intermediate frequency FPGA in the RRU boards detects
the forward and backward feedback signal energy coupled from the antenna port.
Description
With a period of 10 ms, the RRU FPGA detects the transmitting power and reflecting power
coupled from a antenna port and calculates the standing wave of the antenna port based
on a formula. he BSP averages the values once per ten times of readings (in 100 ms) from
the FPGA and reports the average value as the current VSWR.
2-2
SJ-20100510160815-008|2011-01-04(R5.0)
Updates
The FPGA samples once every 10 ms and averages the values once per 10 samplings,
that is, the counter will be updated every 100 ms.
Short Form
VSWR_3
Sampling Period
15 minutes
Counter Type
Maximum Value
Unit
times
Measurement Object
Board
Sampling Point
This counter is udated when the intermediate frequency FPGA in the RRU boards detects
the forward and backward feedback signal energy coupled from the antenna port.
Description
With a period of 10 ms, the RRU FPGA detects the transmitting power and reflecting power
coupled from a antenna port and calculates the standing wave of the antenna port based
on a formula. he BSP averages the values once per ten times of readings (in 100 ms) from
the FPGA and reports the average value as the current VSWR.
Updates
The FPGA samples once every 10 ms and averages the values once per 10 samplings,
that is, the counter will be updated every 100 ms.
2-3
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
VSWR_4
Sampling Period
15 minutes
Counter Type
Maximum Value
Unit
times
Measurement Object
Board
Sampling Point
This counter is udated when the intermediate frequency FPGA in the RRU boards detects
the forward and backward feedback signal energy coupled from the antenna port.
Description
With a period of 10 ms, the RRU FPGA detects the transmitting power and reflecting power
coupled from a antenna port and calculates the standing wave of the antenna port based
on a formula. he BSP averages the values once per ten times of readings (in 100 ms) from
the FPGA and reports the average value as the current VSWR.
Updates
The FPGA samples once every 10 ms and averages the values once per 10 samplings,
that is, the counter will be updated every 100 ms.
2-4
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
VSWR_5
Sampling Period
15 minutes
Counter Type
Maximum Value
Unit
times
Measurement Object
Board
Sampling Point
This counter is udated when the intermediate frequency FPGA in the RRU boards detects
the forward and backward feedback signal energy coupled from the antenna port.
Description
With a period of 10 ms, the RRU FPGA detects the transmitting power and reflecting power
coupled from a antenna port and calculates the standing wave of the antenna port based
on a formula. he BSP averages the values once per ten times of readings (in 100 ms) from
the FPGA and reports the average value as the current VSWR.
Updates
The FPGA samples once every 10 ms and averages the values once per 10 samplings,
that is, the counter will be updated every 100 ms.
Short Form
VSWR_6
Sampling Period
15 minutes
2-5
SJ-20100510160815-008|2011-01-04(R5.0)
Counter Type
Maximum Value
Unit
times
Measurement Object
Board
Sampling Point
This counter is udated when the intermediate frequency FPGA in the RRU boards detects
the forward and backward feedback signal energy coupled from the antenna port.
Description
With a period of 10 ms, the RRU FPGA detects the transmitting power and reflecting power
coupled from a antenna port and calculates the standing wave of the antenna port based
on a formula. he BSP averages the values once per ten times of readings (in 100 ms) from
the FPGA and reports the average value as the current VSWR.
Updates
The FPGA samples once every 10 ms and averages the values once per 10 samplings,
that is, the counter will be updated every 100 ms.
2-6
SJ-20100510160815-008|2011-01-04(R5.0)
Chapter 3
E1 T1 Transmission
Measurement
Table of Contents
C372430000 Framer Type..........................................................................................3-1
C372430001 Error Second Count...............................................................................3-2
C372430002 Server Error Second Count ...................................................................3-3
C372430003 Background Block Error Count ..............................................................3-4
C372430004 Unavailable Second Count ....................................................................3-5
C372430005 Error Second Ratio................................................................................3-5
C372430006 Server Error Second Ratio ....................................................................3-6
C372430007 Background Block Error Ratio ...............................................................3-7
C372430008 Unavailable Second Ratio .....................................................................3-8
C372430009 Frame Alignment Signal Error Count .....................................................3-9
C372430010 CRC Error Count.................................................................................3-10
C372430011 Slip Error Count...................................................................................3-10
C372430012 Code Violation Count ..........................................................................3-11
C372430013 E-bit Error Count .................................................................................3-12
C372430014 Bit Error Ratio......................................................................................3-13
Short Form
Frame_Type
Sampling Period
15 minutes
Counter Type
Approximation Value
3-1
SJ-20100510160815-008|2011-01-04(R5.0)
Unit
times
Measurement Object
E1T1
Sampling Point
When the frame type changes, the counter reads the corresponding value.
Description
If the counter reads 1, the frame type is E1 Double Frame. If the counter reads 2, the
frame type is E1 CRC Multiframe. If the counter reads 3, the frame type is T1 Superframe.
If the counter reads 4, the frame type is T1 Extended Superframe.
Updates
This counter is updated when the frame type changes.
Short Form
ES
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
E1T1
3-2
SJ-20100510160815-008|2011-01-04(R5.0)
Sampling Point
This counter is updated when an errored second is detected in a sampling period.
Description
This counter counts the seconds in which at least one LOS/LOF/AIS/FAS/CRC error occurs
on the E1/T1 link during a sampling period.
Updates
This counter increases by 1 when an second in which an LOS/LOF/AIS/FAS/CRC error
occurs is detected on the E1/T1 link during a sampling period.
Short Form
SES
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
E1T1
Sampling Point
This counter is updated when a severely errored second is detected in a sampling period.
Description
This counter counts the seconds in which errored packets (LOS/LOF/AIS/FAS/CRC error)
exceed 30% of the total packets tranmitted on the E1/T1 link in a sampling period.
3-3
SJ-20100510160815-008|2011-01-04(R5.0)
Updates
This counter increases by 1 when errored packets (LOS/LOF/AIS/FAS/CRC error) exceed
30% of the total packets transmitted on the E1/T1 link in a second during a sampling period.
Short Form
BBE
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
E1T1
Sampling Point
This counter is updated when an background block error is detected in a sampling period.
Description
This counter counts the total FAS or CRC errors that occur on the E1/T1 link in a sampling
period.
Updates
This counter increases by 1 when an FAS or CRC error is detected on the E1/T1 link in a
sampling period.
3-4
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
UAS
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
E1T1
Sampling Point
This counter is updated when an unavailable second is detected in a sampling period.
Description
An E1/T1 link is unavailable if 10 consecutive severely errored seconds (SES) occur on
it, and is recovered if no SES occurs in 10 consecutive seconds. This counter counts the
seconds in which the link is unavailable during a sampling period.
Updates
This counter increases by 1 when an SES occurs after 10 consecutive SESs on the E1/T1
link in a sampling period.
3-5
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
ESR
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
E1T1
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the ratio of the number of errored seconds to the total seconds in
which the link is available in a sampling period.
Updates
The errored second ratio in a sampling period is obtained by dividing the number of errored
seconds by the total seconds in which the link is available at the end of the sampling period.
Short Form
SESR
Sampling Period
15 minutes
3-6
SJ-20100510160815-008|2011-01-04(R5.0)
Counter Type
Average Value
Unit
times
Measurement Object
E1T1
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the ratio of the number of severely errored seconds to the total
seconds in which the link is available in a sampling period.
Updates
The severely errored second ratio in a sampling period is obtained by dividing the number
of severely errored seconds by the total seconds in which the link is available at the end
of the sampling period.
Short Form
BBER
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
3-7
SJ-20100510160815-008|2011-01-04(R5.0)
Measurement Object
E1T1
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the ratio of the number of background block errors to the total data
blocks in a sampling period.
Updates
The background block error ratio in a sampling period is obtained by dividing the number
of background block errors by the total data blocks at the end of the sampling period.
Short Form
UASR
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
E1T1
Sampling Point
This counter is updated at the end of a sampling period.
3-8
SJ-20100510160815-008|2011-01-04(R5.0)
Description
This counter calculates the ratio of the number of unavailable seconds to the total seconds
in a sampling period.
Updates
The unavailable second ratio in a sampling period is obtained by dividing the number of
unavailable seconds by the total seconds at the end of the sampling period.
Short Form
FAS_Err_Count
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
E1T1
Sampling Point
This counter is updated when a frame alignment signal error is detected in a sampling
period.
Description
This counter counts the total frame alignment signal errors in a sampling period.
Updates
This counter increases by 1 when a frame alignment signal error is detected on the E1/T1
link in a sampling period.
3-9
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
CRC_Err_Count
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
E1T1
Sampling Point
This counter is updated when a CRC error is detected in a sampling period.
Description
This counter counts the total CRC errors in a sampling period.
Updates
This counter increases by 1 when a CRC error is detected on the E1/T1 link in a sampling
period.
Short Form
Slip_Count
3-10
SJ-20100510160815-008|2011-01-04(R5.0)
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
E1T1
Sampling Point
This counter is updated when a slip error is detected in a sampling period.
Description
This counter counts the total slip errors in a sampling period.
Updates
This counter increases by 1 when a slip error is detected on the E1/T1 link in a sampling
period.
Short Form
CV_Count
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
3-11
SJ-20100510160815-008|2011-01-04(R5.0)
Measurement Object
E1T1
Sampling Point
This counter is updated when a code violation is detected in a sampling period.
Description
This counter counts the total code violations in a sampling period.
Updates
This counter increases by 1 when a code violation is detected on the E1/T1 link in a
sampling period.
Short Form
E-bit_Error_Count
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
E1T1
Sampling Point
This counter is updated when an E-bit error is detected in a sampling period.
Description
This counter counts the total E-bit errors in a sampling period.
3-12
SJ-20100510160815-008|2011-01-04(R5.0)
Updates
This counter increases by 1 when an E-bit error is detected on the E1/T1 link in a sampling
period.
Short Form
BER
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
E1T1
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the bit error ratio in a sampling period.
Updates
The bit error ratio in a sampling period is obtained by dividing the number of bit errors by
the total bits at the end of the sampling period.
3-13
SJ-20100510160815-008|2011-01-04(R5.0)
3-14
SJ-20100510160815-008|2011-01-04(R5.0)
Chapter 4
FE Transmission
Measurement
Table of Contents
C372440000 Send Bytes............................................................................................4-1
C372440001 Receive Bytes .......................................................................................4-2
C372440002 Average Send Speed ............................................................................4-3
C372440003 Average Receive Speed........................................................................4-4
C372440004 Maximum Send Speed ..........................................................................4-4
C372440005 Maximum Receive Speed......................................................................4-5
C372440006 Average Send Bandwidth ......................................................................4-6
C372440007 Ratio of Average Receive Bandwidth.....................................................4-7
C372440008 Maximum Send Bandwidth ....................................................................4-8
C372440009 Ratio of Maximum Receive Bandwidth ..................................................4-8
C372440010 Average Configured Bandwidth .............................................................4-9
C372440011 Average Physical Bandwidth ...............................................................4-10
C372440012 Bandwidth Threshold...........................................................................4-11
C372440013 Ratio of Send Bandwidth Over Threshold ............................................4-12
C372440014 Ratio of Receive Bandwidth Over Threshold .......................................4-13
Short Form
Send_Bytes
Sampling Period
15 minutes
Counter Type
Accumulation
4-1
SJ-20100510160815-008|2011-01-04(R5.0)
Unit
times
Measurement Object
FE Port
Sampling Point
This counter is updated when data is sent in a sampling period.
Description
This counter counts the total bytes sent in a sampling period.
Updates
This counter adds the bytes contained in every packet sent in a sampling period.
Short Form
Receive_Bytes
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
FE Port
Sampling Point
This counter is updated when data is received in a sampling period.
4-2
SJ-20100510160815-008|2011-01-04(R5.0)
Description
This counter counts the total bytes received in a sampling period.
Updates
This counter adds the bytes contained in every packet received in a sampling period.
Short Form
Average_Send_Speed
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
FE Port
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the average transmitting rate in a sampling period.
Updates
The average transmitting rate in a sampling period is obtained by dividing the total sent
bytes by the sampling period at the end of this period.
4-3
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Average_Receive_Speed
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
FE Port
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the average receiving rate in a sampling period.
Updates
The average receiving rate in a sampling period is obtained by dividing the total received
bytes by the sampling period at the end of this period.
Short Form
Maximum_Send_Speed
4-4
SJ-20100510160815-008|2011-01-04(R5.0)
Sampling Period
15 minutes
Counter Type
Maximum value
Unit
times
Measurement Object
FE Port
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the maximum transmitting rate in a sampling period.
Updates
The maximum transmitting rate in a sampling period is calculated at the end of the sampling
period.
Short Form
Maximum_Receive_Speed
Sampling Period
15 minutes
Counter Type
Maximum value
Unit
times
4-5
SJ-20100510160815-008|2011-01-04(R5.0)
Measurement Object
FE Port
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the maximum receiving rate in a sampling period.
Updates
The maximum receiving rate in a sampling period is calculated at the end of the sampling
period.
Short Form
Average_Send_Bandwidth
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
FE Port
Sampling Point
This counter is updated at the end of a sampling period.
4-6
SJ-20100510160815-008|2011-01-04(R5.0)
Description
This counter calculates the average occupancy rate of the transmitting bandwidth in a
sampling period.
Updates
The average occupancy rate of the transmitting bandwidth in a sampling period is
calculated at the end of the sampling period.
Short Form
Average_Receive_Bandwidth
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
FE Port
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the average occupancy rate of the receiving bandwidth in a
sampling period.
Updates
The average occupancy rate of the receiving bandwidth in a sampling period is calculated
at the end of the sampling period.
4-7
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Maximum_Send_Bandwidth
Sampling Period
15 minutes
Counter Type
Maximum value
Unit
times
Measurement Object
FE Port
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the maximum occupancy rate of the transmitting bandwidth in a
sampling period.
Updates
The maximum occupancy rate of the transmitting bandwidth in a sampling period is
calculated at the end of the sampling period.
4-8
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Maximum_Receive_Bandwidth
Sampling Period
15 minutes
Counter Type
Maximum value
Unit
times
Measurement Object
FE Port
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the maximum occupancy rate of the receiving bandwidth in a
sampling period.
Updates
The maximum occupancy rate of the receiving bandwidth in a sampling period is calculated
at the end of the sampling period.
Short Form
Average_Configured_Bandwidth
Sampling Period
15 minutes
4-9
SJ-20100510160815-008|2011-01-04(R5.0)
Counter Type
Average Value
Unit
times
Measurement Object
FE Port
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the average Configured bandwidth at the FE port.
Updates
The average Configured bandwidth in a sampling period is calculated at the end of the
sampling period.
Short Form
Average_Physical_Bandwidth
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
FE Port
4-10
SJ-20100510160815-008|2011-01-04(R5.0)
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the average physical bandwidth at the FE port.
Updates
The average physical bandwidth in a sampling period is calculated at the end of the
sampling period.
Short Form
Bandwidth_Threshold
Sampling Period
15 minutes
Counter Type
Approximation Value
Unit
times
Measurement Object
FE Port
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter records the threshold bandwidth occupancy rate at the FE port.
Updates
This counter is not updadted.
4-11
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Ratio_of_Send_Bandwidth_Over_Threshold
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
FE Port
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the ratio of the times for which the occupancy rate of the
transmitting bandwidth exceeds the threshold at the FE port in a sampling period to the
total times of measurements in this period.
Updates
This ratio in a sampling period is obtained by dividing the times for which the
occupancy rate of the transmitting bandwidth exceeds the threshold by the total times of
measurements at the end of the sampling period.
4-12
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Ratio_of_Receive_Bandwidth_Over_Threshold
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
FE Port
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the ratio of the times for which the occupancy rate of the receiving
bandwidth exceeds the threshold at the FE port in a sampling period to the total times of
measurements in this period.
Updates
This ratio in a sampling period is obtained by dividing the times for which the occupancy
rate of the receiving bandwidth exceeds the threshold by the total times of measurements
at the end of the sampling period.
4-13
SJ-20100510160815-008|2011-01-04(R5.0)
4-14
SJ-20100510160815-008|2011-01-04(R5.0)
Chapter 5
IMA Transmission
Measurement
Table of Contents
C372450000 Send Bytes............................................................................................5-1
C372450001 Receive Bytes .......................................................................................5-2
C372450002 Average Send Speed ............................................................................5-3
C372450003 Average Receive Speed........................................................................5-4
C372450004 Maximum Send Speed ..........................................................................5-4
C372450005 Maximum Receive Speed......................................................................5-5
C372450006 Average Send Bandwidth ......................................................................5-6
C372450007 Average Receive Bandwidth..................................................................5-7
C372450008 Maximum Send Bandwidth ....................................................................5-8
C372450009 Maximum Receive Bandwidth ...............................................................5-8
C372450010 Received Error counter..........................................................................5-9
C372450011 Received Busy counter........................................................................5-10
C372450012 Sent Busy counter ...............................................................................5-11
C372450013 Received Drop byte counter(just for aal5)............................................5-12
C372450014 Average Available Bandwidth ..............................................................5-12
C372450015 Average Physical Bandwidth ...............................................................5-13
C372450016 Bandwidth Threshold...........................................................................5-14
C372450017 Ratio of Send Bandwidth Over Threshold ............................................5-15
C372450018 Ratio of Receive Bandwidth Over Threshold .......................................5-16
Short Form
Send_Bytes
Sampling Period
15 minutes
5-1
SJ-20100510160815-008|2011-01-04(R5.0)
Counter Type
Accumulation
Unit
times
Measurement Object
IMA Group
Sampling Point
This counter is updated when data is sent in a sampling period.
Description
This counter counts the total bytes sent by the IMA port in a sampling period.
Updates
This counter adds the bytes contained in every packet sent in a sampling period.
Short Form
Receive_Bytes
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
IMA Group
5-2
SJ-20100510160815-008|2011-01-04(R5.0)
Sampling Point
This counter is updated when data is received in a sampling period.
Description
This counter counts the total bytes received by the IMA port in a sampling period.
Updates
This counter adds the bytes contained in every packet received in a sampling period.
Short Form
Average_Send_Speed
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
IMA Group
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the average transmitting rate at the IMA port in a sampling period.
Updates
The average transmitting rate in a sampling period is obtained by dividing the total sent
bytes by the sampling period at the end of this period.
5-3
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Average_Receive_Speed
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
IMA Group
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the average receiving rate at the IMA port in a sampling period.
Updates
The average receiving rate in a sampling period is obtained by dividing the total received
bytes by the sampling period at the end of this period.
Short Form
Maximum_Send_Speed
5-4
SJ-20100510160815-008|2011-01-04(R5.0)
Sampling Period
15 minutes
Counter Type
Maximum value
Unit
times
Measurement Object
IMA Group
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the maximum transmitting rate at the IMA port in a sampling period.
Updates
The maximum transmitting rate in a sampling period is calculated at the end of the sampling
period.
Short Form
Maximum_Receive_Speed
Sampling Period
15 minutes
Counter Type
Maximum value
Unit
times
5-5
SJ-20100510160815-008|2011-01-04(R5.0)
Measurement Object
IMA Group
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the maximum receiving rate at the IMA port in a sampling period.
Updates
The maximum receiving rate in a sampling period is calculated at the end of the sampling
period.
Short Form
Average_Send_Bandwidth
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
IMA Group
Sampling Point
This counter is updated at the end of a sampling period.
5-6
SJ-20100510160815-008|2011-01-04(R5.0)
Description
This counter calculates the average occupancy rate of the transmitting bandwidth at the
IMA port in a sampling period.
Updates
The average occupancy rate of the transmitting bandwidth in a sampling period is
calculated at the end of the sampling period.
Short Form
Average_Receive_Bandwidth
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
IMA Group
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the average occupancy rate of the receiving bandwidth at the IMA
port in a sampling period.
Updates
The average occupancy rate of the receiving bandwidth in a sampling period is calculated
at the end of the sampling period.
5-7
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Maximum_Send_Bandwidth
Sampling Period
15 minutes
Counter Type
Maximum value
Unit
times
Measurement Object
IMA Group
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the maximum occupancy rate of the transmitting bandwidth at the
IMA port in a sampling period.
Updates
The maximum occupancy rate of the transmitting bandwidth in a sampling period is
calculated at the end of the sampling period.
5-8
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Maximum_Receive_Bandwidth
Sampling Period
15 minutes
Counter Type
Maximum value
Unit
times
Measurement Object
IMA Group
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the maximum occupancy rate of the receiving bandwidth at the
IMA port in a sampling period.
Updates
The maximum occupancy rate of the receiving bandwidth in a sampling period is calculated
at the end of the sampling period.
Short Form
Received_Error_Count
Sampling Period
15 minutes
5-9
SJ-20100510160815-008|2011-01-04(R5.0)
Counter Type
Accumulation
Unit
times
Measurement Object
IMA Group
Sampling Point
This counter is updated when an errored packet is received in a sampling period.
Description
This counter counts the errored packets received by the IMA port in a sampling period.
Updates
This counter increases by 1 when an errored packet is received in a sampling period.
Short Form
Received_Busy_Count
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
IMA Group
5-10
SJ-20100510160815-008|2011-01-04(R5.0)
Sampling Point
This counter is updated when a Busy packet is received in a sampling period.
Description
This counter counts the Busy packets received by the IMA port in a sampling period.
Updates
This counter increases by 1 when a Busy packet is received in a sampling period.
Short Form
Sendt_Busy_Count
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
IMA Group
Sampling Point
This counter is updated when a Busy packet fails in transmission in a sampling period.
Description
This counter counts the Busy packets that fail in transmission at the IMA port in a sampling
period.
Updates
This counter increases by 1 when a Busy packet fails in transmission in a sampling period.
5-11
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Received_Drop_byte_Count
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
IMA Group
Sampling Point
This counter is updated when an AAL5 packet is dropped in a sampling period.
Description
This counter counts the AAL5 packets dropped at the IMA port in a sampling period.
Updates
This counter increases by 1 when an AAL5 packet is dropped in a sampling period.
Short Form
Average_Available_Bandwidth
5-12
SJ-20100510160815-008|2011-01-04(R5.0)
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
IMA Group
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the average available bandwidth at the IMA port.
Updates
The average available bandwidth at the IMA port in a sampling period is calculated at the
end of the sampling period.
Short Form
Average_Physical_Bandwidth
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
5-13
SJ-20100510160815-008|2011-01-04(R5.0)
Measurement Object
IMA Group
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the average physical bandwidth at the IMA port.
Updates
The average physical bandwidth at the IMA port in a sampling period is calculated at the
end of the sampling period.
Short Form
Bandwidth_Threshold
Sampling Period
15 minutes
Counter Type
Approximation Value
Unit
times
Measurement Object
IMA Group
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter records the threshold bandwidth occupancy rate at the IMA port.
5-14
SJ-20100510160815-008|2011-01-04(R5.0)
Updates
This counter reads a fixed value and is not updated.
Short Form
Ratio_of_Send_Bandwidth_Over_Threshold
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
IMA Group
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the ratio of the times for which the occupancy rate of the
transmitting bandwidth exceeds the threshold at the IMA port in a sampling period to the
total times of measurements in this period.
Updates
This ratio in a sampling period is obtained by dividing the times for which the
occupancy rate of the transmitting bandwidth exceeds the threshold by the total times of
measurements at the end of the sampling period.
5-15
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Ratio_of_Receive_Bandwidth_Over_Threshold
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
IMA Group
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the ratio of the times for which the occupancy rate of the receiving
bandwidth exceeds the threshold at the IMA port in a sampling period to the total times of
measurements in this period.
Updates
This ratio in a sampling period is obtained by dividing the times for which the occupancy
rate of the receiving bandwidth exceeds the threshold by the total times of measurements
at the end of the sampling period.
5-16
SJ-20100510160815-008|2011-01-04(R5.0)
Chapter 6
PVC Transmission
Measurement
Table of Contents
C372460000 Send Bytes............................................................................................6-1
C372460001 Receive Bytes .......................................................................................6-2
C372460002 Average Send Speed ............................................................................6-3
C372460003 Average Receive Speed........................................................................6-4
C372460004 Maximum Send Speed ..........................................................................6-4
C372460005 Maximum Receive Speed......................................................................6-5
C372460006 Average Send Bandwidth ......................................................................6-6
C372460007 Maximum Send Bandwidth ....................................................................6-7
C372460008 Received Error counter..........................................................................6-8
C372460009 Received Busy counter .........................................................................6-8
C372460010 Sent Busy counter .................................................................................6-9
C372460011 Received Drop byte counter(just for aal5) ............................................6-10
C372460012 Average Config Bandwidth ..................................................................6-11
C372460013 Bandwidth Threshold...........................................................................6-12
C372460014 Ratio of Send Bandwidth Over Threshold ............................................6-12
Short Form
Send_Bytes
Sampling Period
15 minutes
Counter Type
Accumulation
6-1
SJ-20100510160815-008|2011-01-04(R5.0)
Unit
times
Measurement Object
PVC Link
Sampling Point
This counter is updated when data is sent in a sampling period.
Description
This counter counts the total bytes sent by the PVC port in a sampling period.
Updates
This counter adds the bytes contained in every packet sent by the PVC port in a sampling
period.
Short Form
Receive_Bytes
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
PVC Link
Sampling Point
This counter is updated when data is received in a sampling period.
6-2
SJ-20100510160815-008|2011-01-04(R5.0)
Description
This counter counts the total bytes received by the PVC port in a sampling period.
Updates
This counter adds the bytes contained in every packet received by the PVC port in a
sampling period.
Short Form
Average_Send_Speed
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
PVC Link
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the average transmitting rate at the PVC port in a sampling period.
Updates
The average transmitting rate in a sampling period is obtained by dividing the total bytes
sent by the PVC port by the sampling period at the end of this period.
6-3
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Average_Receive_Speed
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
PVC Link
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the average receiving rate at the PVC port in a sampling period.
Updates
The average receiving rate in a sampling period is obtained by dividing the total bytes
received by the PVC port by the sampling period at the end of this period.
Short Form
Maximum_Send_Speed
6-4
SJ-20100510160815-008|2011-01-04(R5.0)
Sampling Period
15 minutes
Counter Type
Maximum value
Unit
times
Measurement Object
PVC Link
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the maximum transmitting rate at the PVC port in a sampling period.
Updates
The maximum transmitting rate at the PVC port in a sampling period is calculated at the
end of the sampling period.
Short Form
Maximum_Receive_Speed
Sampling Period
15 minutes
Counter Type
Maximum value
Unit
times
6-5
SJ-20100510160815-008|2011-01-04(R5.0)
Measurement Object
PVC Link
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the maximum receiving rate at the PVC port in a sampling period.
Updates
The maximum receiving rate at the PVC port in a sampling period is calculated at the end
of the sampling period.
Short Form
Average_Send_Bandwidth
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
PVC Link
Sampling Point
This counter is updated at the end of a sampling period.
6-6
SJ-20100510160815-008|2011-01-04(R5.0)
Description
This counter calculates the average occupancy rate of the transmitting bandwidth at the
PVC port in a sampling period.
Updates
The average occupancy rate of the transmitting bandwidth at the PVC port in a sampling
period is calculated at the end of the sampling period.
Short Form
Maximum_Send_Bandwidth
Sampling Period
15 minutes
Counter Type
Maximum value
Unit
times
Measurement Object
PVC Link
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the maximum occupancy rate of the transmitting bandwidth at the
PVC port in a sampling period.
Updates
The maximum occupancy rate of the transmitting bandwidth at the PVC port in a sampling
period is calculated at the end of the sampling period.
6-7
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Received_Error_Count
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
PVC Link
Sampling Point
This counter is updated when an errored packet is received by the PVC port in a sampling
period.
Description
This counter counts the errored packets received by the PVC port in a sampling period.
Updates
This counter increases by 1 when an errored packet is received in a sampling period.
Short Form
Received_Busy_Count
6-8
SJ-20100510160815-008|2011-01-04(R5.0)
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
PVC Link
Sampling Point
This counter is updated when a Busy packet is received by the PVC port in a sampling
period.
Description
This counter counts the Busy packets received by the PVC port in a sampling period.
Updates
This counter increases by 1 when a Busy packet is received in a sampling period.
Short Form
Sent_Busy_Count
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
6-9
SJ-20100510160815-008|2011-01-04(R5.0)
Measurement Object
PVC Link
Sampling Point
This counter is updated when a Busy packet fails in transmission at the PVC port in a
sampling period.
Description
This counter counts the Busy packets that fail in transmission at the PVC port in a sampling
period.
Updates
This counter increases by 1 when a Busy packet fails in transmission in a sampling period.
Short Form
Received_Drop_byte_Count
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
PVC Link
Sampling Point
This counter is updated when an AAL5 packet is dropped at the PVC port in a sampling
period.
6-10
SJ-20100510160815-008|2011-01-04(R5.0)
Description
This counter counts the AAL5 packets dropped at the PVC port in a sampling period.
Updates
This counter increases by 1 when an AAL5 packet is dropped in a sampling period.
Short Form
Average_Config_Bandwidth
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
PVC Link
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the average configured bandwidth at the PVC port in a sampling
period.
Updates
The average configured bandwidth at the PVC port in a sampling period is calculated at
the end of the sampling period.
6-11
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Bandwidth_Threshold
Sampling Period
15 minutes
Counter Type
Approximation Value
Unit
times
Measurement Object
PVC Link
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter records the threshold bandwidth occupancy rate at the PVC port.
Updates
This counter reads a fixed value and is not updated.
6-12
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Ratio_of_Send_Bandwidth_Over_Threshold
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
PVC Link
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the ratio of the times for which the occupancy rate of the
transmitting bandwidth exceeds the threshold at the PVC port in a sampling period.
Updates
This ratio in a sampling period is obtained by dividing the times for which the
occupancy rate of the transmitting bandwidth exceeds the threshold by the total times of
measurements at the end of the sampling period.
6-13
SJ-20100510160815-008|2011-01-04(R5.0)
6-14
SJ-20100510160815-008|2011-01-04(R5.0)
Chapter 7
PPP Transmission
Measurement
Table of Contents
C372470000 Send Bytes............................................................................................7-1
C372470001 Receive Bytes .......................................................................................7-2
C372470002 Average Send Speed ............................................................................7-3
C372470003 Average Receive Speed........................................................................7-4
C372470004 Maximum Send Speed ..........................................................................7-4
C372470005 Maximum Receive Speed......................................................................7-5
C372470006 Average Send Bandwidth ......................................................................7-6
C372470007 Average Receive Bandwidth..................................................................7-7
C372470008 Maximum Send Bandwidth ....................................................................7-8
C372470009 Maximum Receive Bandwidth ...............................................................7-8
C372470010 Received FCS error counter ..................................................................7-9
C372470011 Received longer than MRU frame/fragment counter ............................7-10
C372470012 Received Terminated frame count .......................................................7-11
C372470013 Received illegal frame counter ............................................................7-12
C372470014 Received frame with invalid Address & control character.....................7-13
C372470015 Average Available Bandwidth ..............................................................7-13
C372470016 Average Physical Bandwidth ...............................................................7-14
C372470017 Bandwidth Threshold...........................................................................7-15
C372470018 Ratio of Send Bandwidth Over Threshold ............................................7-16
C372470019 Ratio of Receive Bandwidth Over Threshold .......................................7-17
Short Form
Send_Bytes
Sampling Period
15 minutes
7-1
SJ-20100510160815-008|2011-01-04(R5.0)
Counter Type
Accumulation
Unit
times
Measurement Object
PPP Link
Sampling Point
This counter is updated when data is sent in a sampling period.
Description
This counter counts the total bytes sent by the PPP port in a sampling period.
Updates
This counter adds the bytes contained in every packet sent by the PPP port in a sampling
period.
Short Form
Received_Bytes
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
PPP Link
7-2
SJ-20100510160815-008|2011-01-04(R5.0)
Sampling Point
This counter is updated when data is received in a sampling period.
Description
This counter counts the total bytes received by the PPP port in a sampling period.
Updates
This counter adds the bytes contained in every packet received by the PPP port in a
sampling period.
Short Form
Average_Send_Speed
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
PPP Link
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the average transmitting rate at the PPP port in a sampling period.
Updates
The average transmitting rate in a sampling period is obtained by dividing the total bytes
sent by the PPP port by the sampling period at the end of this period.
7-3
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Average_Receive_Speed
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
PPP Link
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the average receiving rate at the PPP port in a sampling period.
Updates
The average receiving rate in a sampling period is obtained by dividing the total bytes
received by the PPP port by the sampling period at the end of this period.
Short Form
Maximum_Send_Speed
7-4
SJ-20100510160815-008|2011-01-04(R5.0)
Sampling Period
15 minutes
Counter Type
Maximum value
Unit
times
Measurement Object
PPP Link
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the maximum transmitting rate at the PPP port in a sampling period.
Updates
The maximum transmitting rate at the PPP port in a sampling period is calculated at the
end of the sampling period.
Short Form
Maximum_Receive_Speed
Sampling Period
15 minutes
Counter Type
Maximum value
Unit
times
7-5
SJ-20100510160815-008|2011-01-04(R5.0)
Measurement Object
PPP Link
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the maximum receiving rate at the PPP port in a sampling period.
Updates
The maximum receiving rate at the PPP port in a sampling period is calculated at the end
of the sampling period.
Short Form
Average_Send_Bandwidth
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
PPP Link
Sampling Point
This counter is updated at the end of a sampling period.
7-6
SJ-20100510160815-008|2011-01-04(R5.0)
Description
This counter calculates the average occupancy rate of the transmitting bandwidth at the
PPP port in a sampling period.
Updates
The average occupancy rate of the transmitting bandwidth at the PPP port in a sampling
period is calculated at the end of the sampling period.
Short Form
Average_Receive_Bandwidth
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
PPP Link
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the average occupancy rate of the receiving bandwidth at the PPP
port in a sampling period.
Updates
The average occupancy rate of the receiving bandwidth at the PPP port in a sampling
period is calculated at the end of the sampling period.
7-7
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Maximum_Send_Bandwidth
Sampling Period
15 minutes
Counter Type
Maximum value
Unit
times
Measurement Object
PPP Link
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the maximum occupancy rate of the transmitting bandwidth at the
PPP port in a sampling period.
Updates
The maximum occupancy rate of the transmitting bandwidth at the PPP port in a sampling
period is calculated at the end of the sampling period.
7-8
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Maximum_Receive_Bandwidth
Sampling Period
15 minutes
Counter Type
Maximum value
Unit
times
Measurement Object
PPP Link
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the maximum occupancy rate of the receiving bandwidth at the
PPP port in a sampling period.
Updates
The maximum occupancy rate of the receiving bandwidth at the PPP port in a sampling
period is calculated at the end of the sampling period.
Short Form
Received_FCS_error_Count
Sampling Period
15 minutes
7-9
SJ-20100510160815-008|2011-01-04(R5.0)
Counter Type
Accumulation
Unit
times
Measurement Object
PPP Link
Sampling Point
This counter is updated when an FCS error is received by the PPP port in a sampling
period.
Description
This counter counts the Frame Check Sequence (FCS) errors received by the PPP port in
a sampling period.
Updates
This counter increases by 1 when an FCS error is received by the PPP port in a sampling
period.
Short Form
Received_Longer_than_MRU_Frame_Count
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
7-10
SJ-20100510160815-008|2011-01-04(R5.0)
Measurement Object
PPP Link
Sampling Point
This counter is updated when a frame that is longer than the MRU is received by the PPP
port in a sampling period.
Description
This counter counts the received frames that are longer than the MRU at the PPP port in
a sampling period.
Updates
This counter increases by 1 when a frame that is longer than the MRU is received by the
PPP port in a sampling period.
Short Form
Received_Terminater_Frame_Count
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
PPP Link
Sampling Point
This counter is updated when a terminating frame is received by the PPP port in a sampling
period.
7-11
SJ-20100510160815-008|2011-01-04(R5.0)
Description
This counter counts the terminating frames received at the PPP port in a sampling period.
Updates
This counter increases by 1 when a terminating frame is received by the PPP port in a
sampling period.
Short Form
Received_Illegal_Frame_Count
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
PPP Link
Sampling Point
This counter is updated when an illegal frame is received by the PPP port in a sampling
period.
Description
This counter counts the illegal frames received at the PPP port in a sampling period.
Updates
This counter increases by 1 when an illegal frame is received by the PPP port in a sampling
period.
7-12
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Received_Frame_with_Invalid_Address_and_Control_Character
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
PPP Link
Sampling Point
This counter is updated when a frame with invalid address and control character is received
by the PPP port in a sampling period.
Description
This counter counts the received frames with invalid address and control character at the
PPP port in a sampling period.
Updates
This counter increases by 1 when a frame with invalid address and control character is
received by the PPP port in a sampling period.
Short Form
Average_Available_Bandwidth
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
PPP Link
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the average available bandwidth at the PPP port.
Updates
The average available bandwidth in a sampling period is calculated at the end of the
sampling period.
Short Form
Average_Physical_Bandwidth
Sampling Period
15 minutes
Counter Type
Average Value
7-14
SJ-20100510160815-008|2011-01-04(R5.0)
Unit
times
Measurement Object
PPP Link
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the average physical bandwidth at the PPP port.
Updates
The average physical bandwidth in a sampling period is calculated at the end of the
sampling period.
Short Form
Bandwidth_Threshold
Sampling Period
15 minutes
Counter Type
Approximation Value
Unit
times
Measurement Object
PPP Link
Sampling Point
This counter is updated at the end of a sampling period.
7-15
SJ-20100510160815-008|2011-01-04(R5.0)
Description
This counter records the threshold bandwidth occupancy rate at the PPP port.
Updates
This counter reads a fixed value and is not updated.
Short Form
Ratio_of_Send_Bandwidth_Over_Threshold
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
PPP Link
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the ratio of the times for which the occupancy rate of the
transmitting bandwidth exceeds the threshold at the PPP port in a sampling period to the
total times of measurements in this period.
7-16
SJ-20100510160815-008|2011-01-04(R5.0)
Updates
This ratio in a sampling period is obtained by dividing the times for which the
occupancy rate of the transmitting bandwidth exceeds the threshold by the total times of
measurements at the end of the sampling period.
Short Form
Ratio_of_Receive_Bandwidth_Over_Threshold
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
PPP Link
Sampling Point
This counter is updated at the end of a sampling period.
Description
This counter calculates the ratio of the times for which the occupancy rate of the receiving
bandwidth exceeds the threshold at the PPP port in a sampling period to the total times of
measurements in this period.
Updates
This ratio in a sampling period is obtained by dividing the times for which the occupancy
rate of the receiving bandwidth exceeds the threshold by the total times of measurements
at the end of the sampling period.
7-17
SJ-20100510160815-008|2011-01-04(R5.0)
7-18
SJ-20100510160815-008|2011-01-04(R5.0)
Chapter 8
8-3
SJ-20100510160815-008|2011-01-04(R5.0)
8-4
SJ-20100510160815-008|2011-01-04(R5.0)
Figure 8-3 The Flow Chart of Cells Maximum Transmission Power Measurement
8-5
SJ-20100510160815-008|2011-01-04(R5.0)
Figure 8-4 The Flow Chart of Hardwares Maximum UL/DL Available CE Quantity
Measurement
8-6
SJ-20100510160815-008|2011-01-04(R5.0)
8-7
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_Transmitting_Antennas
Sampling Period
15 minutes
Counter Type
Maximum value
Unit
times
Measurement Object
Cell
Sampling Point
It is a constant number and does not change after the cell is established.
Description
The number of the transmitting antennas configured in this cell.
Updates
The number of the transmitting antennas configured in this cell. It is a constant number
and does not change after the cell is established.
Short Form
Ant_1_TSSI_Max_Value
Sampling Period
15 minutes
Counter Type
Maximum value
8-8
SJ-20100510160815-008|2011-01-04(R5.0)
Unit
times
Measurement Object
Cell
Sampling Point
The maximum analog transmission power of antenna 1 changes in the counting period.
Description
Antenna 1 reports the TSSI power to CC board every 100 ms. The maximum value in the
counting period is the value of this counter.
Updates
When the maximum TSSI power reported by antenna 1 has any change, this counter is
updated accordingly.
Short Form
Ant_1_TSSI_Min_Value
Sampling Period
15 minutes
Counter Type
Minimum value
Unit
times
Measurement Object
Cell
8-9
SJ-20100510160815-008|2011-01-04(R5.0)
Sampling Point
The average analog transmission power of antenna 1 changes in the counting period.
Description
Antenna 1 reports the TSSI power to CC board every 100 ms. The minimum value in the
counting period is the value of this counter.
Updates
When the minimum TSSI power reported by antenna 1 has any change, this counter is
updated accordingly.
Short Form
Ant_1_TSSI_Average_Value
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
Cell
Sampling Point
The minimum analog transmission power of antenna 1 changes in the counting period.
Description
Antenna 1 reports the TSSI power to CC board every 100 ms. The average value in the
counting period is the value of this counter.
8-10
SJ-20100510160815-008|2011-01-04(R5.0)
Updates
When the average TSSI power reported by antenna 1 has any change, this counter is
updated accordingly.
Short Form
Ant_2_TSSI_Max_Value
Sampling Period
15 minutes
Counter Type
Maximum value
Unit
times
Measurement Object
Cell
Sampling Point
The maximum analog transmission power of antenna 2 changes in the counting period.
Description
Antenna 2 reports the TSSI power to CC board every 100 ms. The maximum value in the
counting period is the value of this counter.
Updates
When the maximum TSSI power reported by antenna 2 has any change, this counter is
updated accordingly.
8-11
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Ant_2_TSSI_Min_Value
Sampling Period
15 minutes
Counter Type
Minimum value
Unit
times
Measurement Object
Cell
Sampling Point
The average analog transmission power of antenna 2 changes in the counting period.
Description
Antenna 2 reports the TSSI power to CC board every 100 ms. The minimum value in the
counting period is the value of this counter.
Updates
When the minimum TSSI power reported by antenna 2 has any change, this counter is
updated accordingly.
8-12
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Ant_2_TSSI_Average_Value
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
Cell
Sampling Point
The minimum analog transmission power of antenna 2 changes in the counting period.
Description
Antenna 2 reports the TSSI power to CC board every 100 ms. The average value in the
counting period is the value of this counter.
Updates
When the average TSSI power reported by antenna 2 has any change, this counter is
updated accordingly.
Short Form
Ant_3_TSSI_Max_Value
Sampling Period
15 minutes
8-13
SJ-20100510160815-008|2011-01-04(R5.0)
Counter Type
Maximum value
Unit
times
Measurement Object
Cell
Sampling Point
The maximum analog transmission power of antenna 3 changes in the counting period.
Description
Antenna 3 reports the TSSI power to CC board every 100 ms. The maximum value in the
counting period is the value of this counter.
Updates
When the maximum TSSI power reported by antenna 3 has any change, this counter is
updated accordingly.
Short Form
Ant_3_TSSI_Min_Value
Sampling Period
15 minutes
Counter Type
Minimum value
Unit
times
8-14
SJ-20100510160815-008|2011-01-04(R5.0)
Measurement Object
Cell
Sampling Point
The average analog transmission power of antenna 3 changes in the counting period.
Description
Antenna 3 reports the TSSI power to CC board every 100 ms. The minimum value in the
counting period is the value of this counter.
Updates
When the minimum TSSI power reported by antenna 3 has any change, this counter is
updated accordingly.
Short Form
Ant_3_TSSI_Average_Value
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
Cell
Sampling Point
The minimum analog transmission power of antenna 3 changes in the counting period.
8-15
SJ-20100510160815-008|2011-01-04(R5.0)
Description
Antenna 3 reports the TSSI power to CC board every 100 ms. The average value in the
counting period is the value of this counter.
Updates
When the average TSSI power reported by antenna 3 has any change, this counter is
updated accordingly.
Short Form
Ant_4_TSSI_Max_Value
Sampling Period
15 minutes
Counter Type
Maximum value
Unit
times
Measurement Object
Cell
Sampling Point
The maximum analog transmission power of antenna 4 changes in the counting period.
Description
Antenna 4 reports the TSSI power to CC board every 100 ms. The maximum value in the
counting period is the value of this counter.
Updates
When the maximum TSSI power reported by antenna 4 has any change, this counter is
updated accordingly.
8-16
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Ant_4_TSSI_Min_Value
Sampling Period
15 minutes
Counter Type
Minimum value
Unit
times
Measurement Object
Cell
Sampling Point
The average analog transmission power of antenna 4 changes in the counting period.
Description
Antenna 4 reports the TSSI power to CC board every 100 ms. The minimum value in the
counting period is the value of this counter.
Updates
When the minimum TSSI power reported by antenna 4 has any change, this counter is
updated accordingly.
8-17
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Ant_4_TSSI_Average_Value
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
Cell
Sampling Point
The minimum analog transmission power of antenna 4 changes in the counting period.
Description
Antenna 4 reports the TSSI power to CC board every 100 ms. The average value in the
counting period is the value of this counter.
Updates
When the average TSSI power reported by antenna 4 has any change, this counter is
updated accordingly.
Short Form
Ant_5_TSSI_Max_Value
Sampling Period
15 minutes
8-18
SJ-20100510160815-008|2011-01-04(R5.0)
Counter Type
Maximum value
Unit
times
Measurement Object
Cell
Sampling Point
The maximum analog transmission power of antenna 5 changes in the counting period.
Description
Antenna 5 reports the TSSI power to CC board every 100 ms. The maximum value in the
counting period is the value of this counter.
Updates
When the maximum TSSI power reported by antenna 5 has any change, this counter is
updated accordingly.
Short Form
Ant_5_TSSI_Min_Value
Sampling Period
15 minutes
Counter Type
Minimum value
Unit
times
8-19
SJ-20100510160815-008|2011-01-04(R5.0)
Measurement Object
Cell
Sampling Point
The average analog transmission power of antenna 5 changes in the counting period.
Description
Antenna 5 reports the TSSI power to CC board every 100 ms. The minimum value in the
counting period is the value of this counter.
Updates
When the minimum TSSI power reported by antenna 5 has any change, this counter is
updated accordingly.
Short Form
Ant_5_TSSI_Average_Value
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
Cell
Sampling Point
The minimum analog transmission power of antenna 5 changes in the counting period.
8-20
SJ-20100510160815-008|2011-01-04(R5.0)
Description
Antenna 5 reports the TSSI power to CC board every 100 ms. The average value in the
counting period is the value of this counter.
Updates
When the average TSSI power reported by antenna 5 has any change, this counter is
updated accordingly.
Short Form
Ant_6_TSSI_Max_Value
Sampling Period
15 minutes
Counter Type
Maximum value
Unit
times
Measurement Object
Cell
Sampling Point
The maximum analog transmission power of antenna 6 changes in the counting period.
Description
Antenna 6 reports the TSSI power to CC board every 100 ms. The maximum value in the
counting period is the value of this counter.
Updates
When the maximum TSSI power reported by antenna 6 has any change, this counter is
updated accordingly.
8-21
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Ant_6_TSSI_Min_Value
Sampling Period
15 minutes
Counter Type
Minimum value
Unit
times
Measurement Object
Cell
Sampling Point
The average analog transmission power of antenna 6 changes in the counting period.
Description
Antenna 6 reports the TSSI power to CC board every 100 ms. The minimum value in the
counting period is the value of this counter.
Updates
When the minimum TSSI power reported by antenna 6 has any change, this counter is
updated accordingly.
8-22
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Ant_6_TSSI_Average_Value
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
Cell
Sampling Point
The minimum analog transmission power of antenna 6 changes in the counting period.
Description
Antenna 6 reports the TSSI power to CC board every 100 ms. The average value in the
counting period is the value of this counter.
Updates
When the average TSSI power reported by antenna 6 has any change, this counter is
updated accordingly.
Short Form
Ant_7_TSSI_Max_Value
Sampling Period
15 minutes
8-23
SJ-20100510160815-008|2011-01-04(R5.0)
Counter Type
Maximum value
Unit
times
Measurement Object
Cell
Sampling Point
The maximum analog transmission power of antenna 7 changes in the counting period.
Description
Antenna 7 reports the TSSI power to CC board every 100 ms. The maximum value in the
counting period is the value of this counter.
Updates
When the maximum TSSI power reported by antenna 7 has any change, this counter is
updated accordingly.
Short Form
Ant_7_TSSI_Min_Value
Sampling Period
15 minutes
Counter Type
Minimum value
Unit
times
8-24
SJ-20100510160815-008|2011-01-04(R5.0)
Measurement Object
Cell
Sampling Point
The average analog transmission power of antenna 7 changes in the counting period.
Description
Antenna 7 reports the TSSI power to CC board every 100 ms. The minimum value in the
counting period is the value of this counter.
Updates
When the minimum TSSI power reported by antenna 7 has any change, this counter is
updated accordingly.
Short Form
Ant_7_TSSI_Average_Value
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
Cell
Sampling Point
The minimum analog transmission power of antenna 7 changes in the counting period.
8-25
SJ-20100510160815-008|2011-01-04(R5.0)
Description
Antenna 7 reports the TSSI power to CC board every 100 ms. The average value in the
counting period is the value of this counter.
Updates
When the average TSSI power reported by antenna 7 has any change, this counter is
updated accordingly.
Short Form
Ant_8_TSSI_Max_Value
Sampling Period
15 minutes
Counter Type
Maximum value
Unit
times
Measurement Object
Cell
Sampling Point
The maximum analog transmission power of antenna 8 changes in the counting period.
Description
Antenna 8 reports the TSSI power to CC board every 100 ms. The maximum value in the
counting period is the value of this counter.
Updates
When the maximum TSSI power reported by antenna 8 has any change, this counter is
updated accordingly.
8-26
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Ant_8_TSSI_Min_Value
Sampling Period
15 minutes
Counter Type
Minimum value
Unit
times
Measurement Object
Cell
Sampling Point
The average analog transmission power of antenna 8 changes in the counting period.
Description
Antenna 8 reports the TSSI power to CC board every 100 ms. The minimum value in the
counting period is the value of this counter.
Updates
When the minimum TSSI power reported by antenna 8 has any change, this counter is
updated accordingly.
8-27
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Ant_8_TSSI_Average_Value
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
Cell
Sampling Point
The minimum analog transmission power of antenna 8 changes in the counting period.
Description
Antenna 8 reports the TSSI power to CC board every 100 ms. The average value in the
counting period is the value of this counter.
Updates
When the average TSSI power reported by antenna 8 has any change, this counter is
updated accordingly.
Short Form
Ant_9_TSSI_Max_Value
Sampling Period
15 minutes
8-28
SJ-20100510160815-008|2011-01-04(R5.0)
Counter Type
Maximum value
Unit
times
Measurement Object
Cell
Sampling Point
The maximum analog transmission power of antenna 9 changes in the counting period.
Description
Antenna 9 reports the TSSI power to CC board every 100 ms. The maximum value in the
counting period is the value of this counter.
Updates
When the maximum TSSI power reported by antenna 9 has any change, this counter is
updated accordingly.
Short Form
Ant_9_TSSI_Min_Value
Sampling Period
15 minutes
Counter Type
Minimum value
Unit
times
8-29
SJ-20100510160815-008|2011-01-04(R5.0)
Measurement Object
Cell
Sampling Point
The average analog transmission power of antenna 9 changes in the counting period.
Description
Antenna 9 reports the TSSI power to CC board every 100 ms. The minimum value in the
counting period is the value of this counter.
Updates
When the minimum TSSI power reported by antenna 9 has any change, this counter is
updated accordingly.
Short Form
Ant_9_TSSI_Average_Value
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
Cell
Sampling Point
The minimum analog transmission power of antenna 9 changes in the counting period.
8-30
SJ-20100510160815-008|2011-01-04(R5.0)
Description
Antenna 9 reports the TSSI power to CC board every 100 ms. The average value in the
counting period is the value of this counter.
Updates
When the average TSSI power reported by antenna 9 has any change, this counter is
updated accordingly.
Short Form
Ant_10_TSSI_Max_Value
Sampling Period
15 minutes
Counter Type
Maximum value
Unit
times
Measurement Object
Cell
Sampling Point
The maximum analog transmission power of antenna 10 changes in the counting period.
Description
Antenna 10 reports the TSSI power to CC board every 100 ms. The maximum value in
the counting period is the value of this counter.
Updates
When the maximum TSSI power reported by antenna 10 has any change, this counter is
updated accordingly.
8-31
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Ant_10_TSSI_Min_Value
Sampling Period
15 minutes
Counter Type
Minimum value
Unit
times
Measurement Object
Cell
Sampling Point
The average analog transmission power of antenna 10 changes in the counting period.
Description
Antenna 10 reports the TSSI power to CC board every 100 ms. The minimum value in the
counting period is the value of this counter.
Updates
When the minimum TSSI power reported by antenna 10 has any change, this counter is
updated accordingly.
8-32
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Ant_10_TSSI_Average_Value
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
Cell
Sampling Point
The minimum analog transmission power of antenna 10 changes in the counting period.
Description
Antenna 10 reports the TSSI power to CC board every 100 ms. The average value in the
counting period is the value of this counter.
Updates
When the average TSSI power reported by antenna 10 has any change, this counter is
updated accordingly.
Short Form
Ant_11_TSSI_Max_Value
Sampling Period
15 minutes
8-33
SJ-20100510160815-008|2011-01-04(R5.0)
Counter Type
Maximum value
Unit
times
Measurement Object
Cell
Sampling Point
The maximum analog transmission power of antenna 11 changes in the counting period.
Description
Antenna 11 reports the TSSI power to CC board every 100 ms. The maximum value in the
counting period is the value of this counter.
Updates
When the maximum TSSI power reported by antenna 11 has any change, this counter is
updated accordingly.
Short Form
Ant_11_TSSI_Min_Value
Sampling Period
15 minutes
Counter Type
Minimum value
Unit
times
8-34
SJ-20100510160815-008|2011-01-04(R5.0)
Measurement Object
Cell
Sampling Point
The average analog transmission power of antenna 11 changes in the counting period.
Description
Antenna 11 reports the TSSI power to CC board every 100 ms. The minimum value in the
counting period is the value of this counter.
Updates
When the minimum TSSI power reported by antenna 11 has any change, this counter is
updated accordingly.
Short Form
Ant_11_TSSI_Average_Value
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
Cell
Sampling Point
The minimum analog transmission power of antenna 11 changes in the counting period.
8-35
SJ-20100510160815-008|2011-01-04(R5.0)
Description
Antenna 11 reports the TSSI power to CC board every 100 ms. The average value in the
counting period is the value of this counter.
Updates
When the average TSSI power reported by antenna 11 has any change, this counter is
updated accordingly.
Short Form
Ant_12_TSSI_Max_Value
Sampling Period
15 minutes
Counter Type
Maximum value
Unit
times
Measurement Object
Cell
Sampling Point
The maximum analog transmission power of antenna 12 changes in the counting period.
Description
Antenna 12 reports the TSSI power to CC board every 100 ms. The maximum value in
the counting period is the value of this counter.
Updates
When the maximum TSSI power reported by antenna 12 has any change, this counter is
updated accordingly.
8-36
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Ant_12_TSSI_Min_Value
Sampling Period
15 minutes
Counter Type
Minimum value
Unit
times
Measurement Object
Cell
Sampling Point
The average analog transmission power of antenna 12 changes in the counting period.
Description
Antenna 12 reports the TSSI power to CC board every 100 ms. The minimum value in the
counting period is the value of this counter.
Updates
When the minimum TSSI power reported by antenna 12 has any change, this counter is
updated accordingly.
8-37
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Ant_12_TSSI_Average_Value
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
Cell
Sampling Point
The minimum analog transmission power of antenna 12 changes in the counting period.
Description
Antenna 12 reports the TSSI power to CC board every 100 ms. The average value in the
counting period is the value of this counter.
Updates
When the average TSSI power reported by antenna 12 has any change, this counter is
updated accordingly.
Short Form
Number_of_Receiving_Antennas
Sampling Period
15 minutes
Counter Type
Maximum value
8-38
SJ-20100510160815-008|2011-01-04(R5.0)
Unit
times
Measurement Object
Cell
Sampling Point
It is a constant number and does not change after the cell is established.
Description
The receiving antenna number configured in the cell.
Updates
The number of the transmission antennas configured in this cell. It is a constant number
and does not change after the cell is established.
Short Form
Ant_1_RSSI_Max_Value
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
Cell
Sampling Point
The maximum analog receiving power of antenna 1 changes in the counting period.
8-39
SJ-20100510160815-008|2011-01-04(R5.0)
Description
Antenna 1 reports the RSSI power to CC board every 100 ms. The maximum value in the
counting period is the value of this counter.
Updates
When the maximum RSSI power reported by antenna 1 has any change, this counter is
updated accordingly.
Short Form
Ant_1_RSSI_Min_Value
Sampling Period
15 minutes
Counter Type
Maximum value
Unit
times
Measurement Object
Cell
Sampling Point
The average analog receiving power of antenna 1 changes in the counting period.
Description
Antenna 1 reports the RSSI power to CC board every 100 ms. The minimum value in the
counting period is the value of this counter.
Updates
When the minimum RSSI power reported by antenna 1 has any change, this counter is
updated accordingly.
8-40
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Ant_1_RSSI_Average_Value
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
Cell
Sampling Point
The minimum analog receiving power of antenna 1 changes in the counting period.
Description
Antenna 1 reports the RSSI power to CC board every 100 ms. The average value in the
counting period is the value of this counter.
Updates
When the average RSSI power reported by antenna 1 has any change, this counter is
updated accordingly.
8-41
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Ant_2_RSSI_Max_Value
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
Cell
Sampling Point
The maximum analog receiving power of antenna 2 changes in the counting period.
Description
Antenna 2 reports the RSSI power to CC board every 100 ms. The maximum value in the
counting period is the value of this counter.
Updates
When the maximum RSSI power reported by antenna 2 has any change, this counter is
updated accordingly.
Short Form
Ant_2_RSSI_Min_Value
Sampling Period
15 minutes
8-42
SJ-20100510160815-008|2011-01-04(R5.0)
Counter Type
Maximum value
Unit
times
Measurement Object
Cell
Sampling Point
The average analog receiving power of antenna 2 changes in the counting period.
Description
Antenna 2 reports the RSSI power to CC board every 100 ms. The minimum value in the
counting period is the value of this counter.
Updates
When the minimum RSSI power reported by antenna 2 has any change, this counter is
updated accordingly.
Short Form
Ant_2_RSSI_Average_Value
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
8-43
SJ-20100510160815-008|2011-01-04(R5.0)
Measurement Object
Cell
Sampling Point
The minimum analog receiving power of antenna 2 changes in the counting period.
Description
Antenna 2 reports the RSSI power to CC board every 100 ms. The average value in the
counting period is the value of this counter.
Updates
When the average RSSI power reported by antenna 2 has any change, this counter is
updated accordingly.
Short Form
Ant_3_RSSI_Max_Value
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
Cell
Sampling Point
The maximum analog receiving power of antenna 3 changes in the counting period.
8-44
SJ-20100510160815-008|2011-01-04(R5.0)
Description
Antenna 3 reports the RSSI power to CC board every 100 ms. The maximum value in the
counting period is the value of this counter.
Updates
When the maximum RSSI power reported by antenna 3 has any change, this counter is
updated accordingly.
Short Form
Ant_3_RSSI_Min_Value
Sampling Period
15 minutes
Counter Type
Maximum value
Unit
times
Measurement Object
Cell
Sampling Point
The average analog receiving power of antenna 3 changes in the counting period.
Description
Antenna 3 reports the RSSI power to CC board every 100 ms. The minimum value in the
counting period is the value of this counter.
Updates
When the minimum RSSI power reported by antenna 3 has any change, this counter is
updated accordingly.
8-45
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Ant_3_RSSI_Average_Value
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
Cell
Sampling Point
The minimum analog receiving power of antenna 3 changes in the counting period.
Description
Antenna 3 reports the RSSI power to CC board every 100 ms. The average value in the
counting period is the value of this counter.
Updates
When the average RSSI power reported by antenna 3 has any change, this counter is
updated accordingly.
8-46
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Ant_4_RSSI_Max_Value
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
Cell
Sampling Point
The maximum analog receiving power of antenna 4 changes in the counting period.
Description
Antenna 4 reports the RSSI power to CC board every 100 ms. The maximum value in the
counting period is the value of this counter.
Updates
When the maximum RSSI power reported by antenna 4 has any change, this counter is
updated accordingly.
Short Form
Ant_4_RSSI_Min_Value
Sampling Period
15 minutes
8-47
SJ-20100510160815-008|2011-01-04(R5.0)
Counter Type
Maximum value
Unit
times
Measurement Object
Cell
Sampling Point
The average analog receiving power of antenna 4 changes in the counting period.
Description
Antenna 4 reports the RSSI power to CC board every 100 ms. The minimum value in the
counting period is the value of this counter.
Updates
When the minimum RSSI power reported by antenna 4 has any change, this counter is
updated accordingly.
Short Form
Ant_4_RSSI_Average_Value
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
8-48
SJ-20100510160815-008|2011-01-04(R5.0)
Measurement Object
Cell
Sampling Point
The minimum analog receiving power of antenna 4 changes in the counting period.
Description
Antenna 4 reports the RSSI power to CC board every 100 ms. The average value in the
counting period is the value of this counter.
Updates
When the average RSSI power reported by antenna 4 has any change, this counter is
updated accordingly.
Short Form
Ant_5_RSSI_Max_Value
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
Cell
Sampling Point
The maximum analog receiving power of antenna 5 changes in the counting period.
8-49
SJ-20100510160815-008|2011-01-04(R5.0)
Description
Antenna 5 reports the RSSI power to CC board every 100 ms. The maximum value in the
counting period is the value of this counter.
Updates
When the maximum RSSI power reported by antenna 5 has any change, this counter is
updated accordingly.
Short Form
Ant_5_RSSI_Min_Value
Sampling Period
15 minutes
Counter Type
Maximum value
Unit
times
Measurement Object
Cell
Sampling Point
The average analog receiving power of antenna 5 changes in the counting period.
Description
Antenna 5 reports the RSSI power to CC board every 100 ms. The minimum value in the
counting period is the value of this counter.
Updates
When the minimum RSSI power reported by antenna 5 has any change, this counter is
updated accordingly.
8-50
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Ant_5_RSSI_Average_Value
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
Cell
Sampling Point
The minimum analog receiving power of antenna 5 changes in the counting period.
Description
Antenna 5 reports the RSSI power to CC board every 100 ms. The average value in the
counting period is the value of this counter.
Updates
When the average RSSI power reported by antenna 5 has any change, this counter is
updated accordingly.
8-51
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Ant_6_RSSI_Max_Value
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
Cell
Sampling Point
The maximum analog receiving power of antenna 6 changes in the counting period.
Description
Antenna 6 reports the RSSI power to CC board every 100 ms. The maximum value in the
counting period is the value of this counter.
Updates
When the maximum RSSI power reported by antenna 6 has any change, this counter is
updated accordingly.
Short Form
Ant_6_RSSI_Min_Value
Sampling Period
15 minutes
8-52
SJ-20100510160815-008|2011-01-04(R5.0)
Counter Type
Maximum value
Unit
times
Measurement Object
Cell
Sampling Point
The average analog receiving power of antenna 6 changes in the counting period.
Description
Antenna 6 reports the RSSI power to CC board every 100 ms. The minimum value in the
counting period is the value of this counter.
Updates
When the minimum RSSI power reported by antenna 6 has any change, this counter is
updated accordingly.
Short Form
Ant_6_RSSI_Average_Value
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
8-53
SJ-20100510160815-008|2011-01-04(R5.0)
Measurement Object
Cell
Sampling Point
The minimum analog receiving power of antenna 6 changes in the counting period.
Description
Antenna 6 reports the RSSI power to CC board every 100 ms. The average value in the
counting period is the value of this counter.
Updates
When the average RSSI power reported by antenna 6 has any change, this counter is
updated accordingly.
Short Form
Ant_7_RSSI_Max_Value
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
Cell
Sampling Point
The maximum analog receiving power of antenna 7 changes in the counting period.
8-54
SJ-20100510160815-008|2011-01-04(R5.0)
Description
Antenna 7 reports the RSSI power to CC board every 100 ms. The maximum value in the
counting period is the value of this counter.
Updates
When the maximum RSSI power reported by antenna 7 has any change, this counter is
updated accordingly.
Short Form
Ant_7_RSSI_Min_Value
Sampling Period
15 minutes
Counter Type
Maximum value
Unit
times
Measurement Object
Cell
Sampling Point
The average analog receiving power of antenna 7 changes in the counting period.
Description
Antenna 7 reports the RSSI power to CC board every 100 ms. The minimum value in the
counting period is the value of this counter.
Updates
When the minimum RSSI power reported by antenna 7 has any change, this counter is
updated accordingly.
8-55
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Ant_7_RSSI_Average_Value
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
Cell
Sampling Point
The minimum analog receiving power of antenna 7 changes in the counting period.
Description
Antenna 7 reports the RSSI power to CC board every 100 ms. The average value in the
counting period is the value of this counter.
Updates
When the average RSSI power reported by antenna 7 has any change, this counter is
updated accordingly.
8-56
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Ant_8_RSSI_Max_Value
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
Cell
Sampling Point
The maximum analog receiving power of antenna 8 changes in the counting period.
Description
Antenna 8 reports the RSSI power to CC board every 100 ms. The maximum value in the
counting period is the value of this counter.
Updates
When the maximum RSSI power reported by antenna 8 has any change, this counter is
updated accordingly.
Short Form
Ant_8_RSSI_Min_Value
Sampling Period
15 minutes
8-57
SJ-20100510160815-008|2011-01-04(R5.0)
Counter Type
Maximum value
Unit
times
Measurement Object
Cell
Sampling Point
The average analog receiving power of antenna 8 changes in the counting period.
Description
Antenna 8 reports the RSSI power to CC board every 100 ms. The minimum value in the
counting period is the value of this counter.
Updates
When the minimum RSSI power reported by antenna 8 has any change, this counter is
updated accordingly.
Short Form
Ant_8_RSSI_Average_Value
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
8-58
SJ-20100510160815-008|2011-01-04(R5.0)
Measurement Object
Cell
Sampling Point
The minimum analog receiving power of antenna 8 changes in the counting period.
Description
Antenna 8 reports the RSSI power to CC board every 100 ms. The average value in the
counting period is the value of this counter.
Updates
When the average RSSI power reported by antenna 8 has any change, this counter is
updated accordingly.
Short Form
Ant_9_RSSI_Max_Value
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
Cell
Sampling Point
The maximum analog receiving power of antenna 9 changes in the counting period.
8-59
SJ-20100510160815-008|2011-01-04(R5.0)
Description
Antenna 9 reports the RSSI power to CC board every 100 ms. The maximum value in the
counting period is the value of this counter.
Updates
When the maximum RSSI power reported by antenna 9 has any change, this counter is
updated accordingly.
Short Form
Ant_9_RSSI_Min_Value
Sampling Period
15 minutes
Counter Type
Maximum value
Unit
times
Measurement Object
Cell
Sampling Point
The average analog receiving power of antenna 9 changes in the counting period.
Description
Antenna 9 reports the RSSI power to CC board every 100 ms. The minimum value in the
counting period is the value of this counter.
Updates
When the minimum RSSI power reported by antenna 9 has any change, this counter is
updated accordingly.
8-60
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Ant_9_RSSI_Average_Value
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
Cell
Sampling Point
The minimum analog receiving power of antenna 9 changes in the counting period.
Description
Antenna 9 reports the RSSI power to CC board every 100 ms. The average value in the
counting period is the value of this counter.
Updates
When the average RSSI power reported by antenna 9 has any change, this counter is
updated accordingly.
8-61
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Ant_10_RSSI_Max_Value
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
Cell
Sampling Point
The maximum analog receiving power of antenna 10 changes in the counting period.
Description
Antenna 10 reports the RSSI power to CC board every 100 ms. The maximum value in
the counting period is the value of this counter.
Updates
When the maximum RSSI power reported by antenna 10 has any change, this counter is
updated accordingly.
Short Form
Ant_10_RSSI_Min_Value
Sampling Period
15 minutes
8-62
SJ-20100510160815-008|2011-01-04(R5.0)
Counter Type
Maximum value
Unit
times
Measurement Object
Cell
Sampling Point
The average analog receiving power of antenna 10 changes in the counting period.
Description
Antenna 10 reports the RSSI power to CC board every 100 ms. The minimum value in the
counting period is the value of this counter.
Updates
When the minimum RSSI power reported by antenna 10 has any change, this counter is
updated accordingly.
Short Form
Ant_10_RSSI_Average_Value
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
8-63
SJ-20100510160815-008|2011-01-04(R5.0)
Measurement Object
Cell
Sampling Point
The minimum analog receiving power of antenna 10 changes in the counting period.
Description
Antenna 10 reports the RSSI power to CC board every 100 ms. The average value in the
counting period is the value of this counter.
Updates
When the average RSSI power reported by antenna 10 has any change, this counter is
updated accordingly.
Short Form
Ant_11_RSSI_Max_Value
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
Cell
Sampling Point
The maximum analog receiving power of antenna 11 changes in the counting period.
8-64
SJ-20100510160815-008|2011-01-04(R5.0)
Description
Antenna 11 reports the RSSI power to CC board every 100 ms. The maximum value in
the counting period is the value of this counter.
Updates
When the maximum RSSI power reported by antenna 11 has any change, this counter is
updated accordingly.
Short Form
Ant_11_RSSI_Min_Value
Sampling Period
15 minutes
Counter Type
Maximum value
Unit
times
Measurement Object
Cell
Sampling Point
The average analog receiving power of antenna 11 changes in the counting period.
Description
Antenna 11 reports the RSSI power to CC board every 100 ms. The minimum value in the
counting period is the value of this counter.
Updates
When the minimum RSSI power reported by antenna 11 has any change, this counter is
updated accordingly.
8-65
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Ant_11_RSSI_Average_Value
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
Cell
Sampling Point
The minimum analog receiving power of antenna 11 changes in the counting period.
Description
Antenna 11 reports the RSSI power to CC board every 100 ms. The average value in the
counting period is the value of this counter.
Updates
When the average RSSI power reported by antenna 11 has any change, this counter is
updated accordingly.
8-66
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Ant_12_RSSI_Max_Value
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
Cell
Sampling Point
The maximum analog receiving power of antenna 12 changes in the counting period.
Description
Antenna 12 reports the RSSI power to CC board every 100 ms. The maximum value in
the counting period is the value of this counter.
Updates
When the maximum RSSI power reported by antenna 12 has any change, this counter is
updated accordingly.
Short Form
Ant_12_RSSI_Min_Value
Sampling Period
15 minutes
8-67
SJ-20100510160815-008|2011-01-04(R5.0)
Counter Type
Maximum value
Unit
times
Measurement Object
Cell
Sampling Point
The average analog receiving power of antenna 12 changes in the counting period.
Description
Antenna 12 reports the RSSI power to CC board every 100 ms. The minimum value in the
counting period is the value of this counter.
Updates
When the minimum RSSI power reported by antenna 12 has any change, this counter is
updated accordingly.
Short Form
Ant_12_RSSI_Average_Value
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
8-68
SJ-20100510160815-008|2011-01-04(R5.0)
Measurement Object
Cell
Sampling Point
The minimum analog receiving power of antenna 12 changes in the counting period.
Description
Antenna 12 reports the RSSI power to CC board every 100 ms. The average value in the
counting period is the value of this counter.
Updates
When the average RSSI power reported by antenna 12 has any change, this counter is
updated accordingly.
Short Form
Available_Hardware_DL_Power
Sampling Period
15 minutes
Counter Type
Maximum value
Unit
times
Measurement Object
Cell
Sampling Point
Modify the local cell configuration information when the maximum transmission power
changes in the local cell.
8-69
SJ-20100510160815-008|2011-01-04(R5.0)
Description
The maximum hardware transmitting power available in the local cell corresponding to this
radio cell.
Updates
When the maximum hardware transmission power available changes in the local cell
corresponding to this radio cell, this counter is updated accordingly.
Short Form
Available_Software_Power
Sampling Period
15 minutes
Counter Type
Maximum value
Unit
times
Measurement Object
Cell
Sampling Point
This counter changes when the base station receives a reconfiguration message from a
cell requiring modifying the maximum transmission power.
Description
This power information is configured in RNC and distributed in cell setting up signalling
and cell reconfiguration signalling.
Updates
RNCWhen the maximum hardware transmitting power available changes in the local cell.
8-70
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Available_Hardware_Channel_Elements__Uplink
Sampling Period
15 minutes
Counter Type
Maximum value
Unit
times
Measurement Object
Cell
Sampling Point
The baseband resource pool corresponding to the cell has any change.
Description
Automatically determined upon the configuration of the local cell group.The maximum
number of uplink CE available is equal to the total number of the uplink baseband board
CE in the baseband resource pool containing the cell.
Updates
The counter is updated when the baseband resource pool corresponding to the cell has
any change.
8-71
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Available_Hardware_Channel_Elements__Downlink
Sampling Period
15 minutes
Counter Type
Maximum value
Unit
times
Measurement Object
Cell
Sampling Point
The baseband resource pool corresponding to the cell has any change.
Description
Automatically determined upon the configuration of the local cell group.The maximum
number of the downlink CE available is equal to the total number of the downlink baseband
board CE in the baseband resource pool containing the cell.
Updates
The counter is updated when the baseband resource pool corresponding to the cell has
any change.
Short Form
Propagation_Delay_Step_1
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
Cell
Sampling Point
Base station receives a request message for setting up a radio link.
Description
When an RL setup request message is received, if RL is the first radio link of UE, the
propagation delay field is configured. Propagation Delay is a rough indicator of the distance
between an UE and the base station. This parameter shows the distribution of UEs.
Updates
When an RL setup request message is received, if RL is the first radio link of UE, the
propagation delay field is configured. The counter adds one when the propagation delay
value is 0.
Short Form
Propagation_Delay_Step_2
Sampling Period
15 minutes
8-73
SJ-20100510160815-008|2011-01-04(R5.0)
Counter Type
Accumulation
Unit
times
Measurement Object
Cell
Sampling Point
Base station receives a request message for setting up a radio link.
Description
When an RL setup request message is received, if RL is the first radio link of UE, the
propagation delay field is configured. Propagation Delay is a rough indicator of the distance
between an UE and the base station. This parameter shows the distribution of UEs.
Updates
When an RL setup request message is received, if RL is the first radio link of UE, the
propagation delay field is configured. The counter adds one when the propagation delay
value is in [1,3].
Short Form
Propagation_Delay_Step_3
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
8-74
SJ-20100510160815-008|2011-01-04(R5.0)
Measurement Object
Cell
Sampling Point
Base station receives a request message for setting up a radio link.
Description
When an RL setup request message is received, if RL is the first radio link of UE, the
propagation delay field is configured. Propagation Delay is a rough indicator of the distance
between an UE and the base station. This parameter shows the distribution of UEs.
Updates
When an RL setup request message is received, if RL is the first radio link of UE, the
propagation delay field is configured. The counter adds one when the propagation delay
value is in [4,5].
Short Form
Propagation_Delay_Step_4
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
Cell
Sampling Point
Base station receives a request message for setting up a radio link.
8-75
SJ-20100510160815-008|2011-01-04(R5.0)
Description
When an RL setup request message is received, if RL is the first radio link of UE, the
propagation delay field is configured. Propagation Delay is a rough indicator of the distance
between an UE and the base station. This parameter shows the distribution of UEs.
Updates
When an RL setup request message is received, if RL is the first radio link of UE, the
propagation delay field is configured. The counter adds one when the propagation delay
value is in [6.7].
Short Form
Propagation_Delay_Step_5
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
Cell
Sampling Point
Base station receives a request message for setting up a radio link.
Description
When an RL setup request message is received, if RL is the first radio link of UE, the
propagation delay field is configured. Propagation Delay is a rough indicator of the distance
between an UE and the base station. This parameter shows the distribution of UEs.
8-76
SJ-20100510160815-008|2011-01-04(R5.0)
Updates
When an RL setup request message is received, if RL is the first radio link of UE, the
propagation delay field is configured. The counter adds one when the propagation delay
value is in [8,9].
Short Form
Propagation_Delay_Step_6
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
Cell
Sampling Point
Base station receives a request message for setting up a radio link.
Description
When an RL setup request message is received, if RL is the first radio link of UE, the
propagation delay field is configured. Propagation Delay is a rough indicator of the distance
between an UE and the base station. This parameter shows the distribution of UEs.
Updates
When an RL setup request message is received, if RL is the first radio link of UE, the
propagation delay field is configured. The counter adds one when the propagation delay
value is in [10,14].
8-77
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Propagation_Delay_Step_7
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
Cell
Sampling Point
Base station receives a request message for setting up a radio link.
Description
When an RL setup request message is received, if RL is the first radio link of UE, the
propagation delay field is configured. Propagation Delay is a rough indicator of the distance
between an UE and the base station. This parameter shows the distribution of UEs.
Updates
When an RL setup request message is received, if RL is the first radio link of UE, the
propagation delay field is configured. The counter adds one when the propagation delay
value is in [15,19].
Short Form
Propagation_Delay_Step_8
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
Cell
Sampling Point
Base station receives a request message for setting up a radio link.
Description
When an RL setup request message is received, if RL is the first radio link of UE, the
propagation delay field is configured. Propagation Delay is a rough indicator of the distance
between an UE and the base station. This parameter shows the distribution of UEs.
Updates
When an RL setup request message is received, if RL is the first radio link of UE, the
propagation delay field is configured. The counter adds one when the propagation delay
value is in [20,29].
Short Form
Propagation_Delay_Step_9
Sampling Period
15 minutes
8-79
SJ-20100510160815-008|2011-01-04(R5.0)
Counter Type
Accumulation
Unit
times
Measurement Object
Cell
Sampling Point
Base station receives a request message for setting up a radio link.
Description
When an RL setup request message is received, if RL is the first radio link of UE, the
propagation delay field is configured. Propagation Delay is a rough indicator of the distance
between an UE and the base station. This parameter shows the distribution of UEs.
Updates
When an RL setup request message is received, if RL is the first radio link of UE, the
propagation delay field is configured. The counter adds one when the propagation delay
value is in [30,39].
Short Form
Propagation_Delay_Step_10
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
8-80
SJ-20100510160815-008|2011-01-04(R5.0)
Measurement Object
Cell
Sampling Point
Base station receives a request message for setting up a radio link.
Description
When an RL setup request message is received, if RL is the first radio link of UE, the
propagation delay field is configured. Propagation Delay is a rough indicator of the distance
between an UE and the base station. This parameter shows the distribution of UEs.
Updates
When an RL setup request message is received, if RL is the first radio link of UE, the
propagation delay field is configured. The counter adds one when the propagation delay
value is in [40,79].
Short Form
Propagation_Delay_Step_11
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
Cell
Sampling Point
Base station receives a request message for setting up a radio link.
8-81
SJ-20100510160815-008|2011-01-04(R5.0)
Description
When an RL setup request message is received, if RL is the first radio link of UE, the
propagation delay field is configured. Propagation Delay is a rough indicator of the distance
between an UE and the base station. This parameter shows the distribution of UEs.
Updates
When an RL setup request message is received, if RL is the first radio link of UE, the
propagation delay field is configured. The counter adds one when the propagation delay
value is in [80,255].
8-82
SJ-20100510160815-008|2011-01-04(R5.0)
Chapter 9
C372490121 Average of Used CQI while MIMO Two Stream ................................. 9-112
C372490122 HSDPA Traffic - QPSK ...................................................................... 9-113
C372490123 HSDPA Traffic - 16 QAM ................................................................... 9-114
C372490124 HSDPA Traffic - 64 QAM ................................................................... 9-115
C372490125 HSDPA - QPSK usage ratio............................................................... 9-116
C372490126 HSDPA - 16 QAM usage ratio ........................................................... 9-117
C372490127 HSDPA - 64 QAM usage ratio ........................................................... 9-118
C372490128 HSDPA Duration Activity ................................................................... 9-119
C372490129 HSDPA Average Throughput per user ............................................... 9-119
C372490130 HSDPA Average user rate distribution 0-8 Kbits/s..............................9-120
C372490131 HSDPA Average user rate distribution 8-32Kbits/s.............................9-121
C372490132 HSDPA Average user rate distribution 32-64Kbits/s...........................9-122
C372490133 HSDPA Average user rate distribution 64-128Kbits/s.........................9-123
C372490134 HSDPA Average user rate distribution 128-256Kbits/s.......................9-124
C372490135 HSDPA Average user rate distribution 256-384Kbits/s.......................9-125
C372490136 HSDPA Average user rate distribution 384-512Kbits/s.......................9-126
C372490137 HSDPA Average user rate distribution 512-768Kbits/s.......................9-127
C372490138 HSDPA Average user rate distribution 768-1024Kbits/s.....................9-128
C372490139 HSDPA Average user rate distribution 1024-1280Kbits/s...................9-129
C372490140 HSDPA Average user rate distribution 1280-1536Kbits/s...................9-130
C372490141 HSDPA Average user rate distribution 1536-1792Kbits/s...................9-131
C372490142 HSDPA Average user rate distribution 1792-2048Kbits/s...................9-132
C372490143 HSDPA Average user rate distribution 2048-2304Kbits/s...................9-133
C372490144 HSDPA Average user rate distribution 2304-2560Kbits/s...................9-134
C372490145 HSDPA Average user rate distribution 2560-2816Kbits/s...................9-135
C372490146 HSDPA Average user rate distribution 2816-3072Kbits/s...................9-136
C372490147 HSDPA Average user rate distribution 3072-3328Kbits/s...................9-137
C372490148 HSDPA Average user rate distribution 3328-3584Kbits/s...................9-138
C372490149 HSDPA Average user rate distribution 3584-4096Kbits/s...................9-139
C372490150 HSDPA Average user rate distribution 4096-5120Kbits/s...................9-140
C372490151 HSDPA Average user rate distribution 5120-6144Kbits/s...................9-141
C372490152 HSDPA Average user rate distribution 6144-7168Kbits/s...................9-142
C372490153 HSDPA Average user rate distribution 7168Kbits/s - inf .....................9-143
C372490154 Number of Received ACK for a given TBS - HSDPA 64 QAM............9-144
C372490155 Number of Received NACK for a given TBS - HSDPA 64 QAM .........9-145
C372490156 Number of Received ACK for a given TBS - HSDPA 16 QAM............9-146
C372490157 Number of Received NACK for a given TBS - HSDPA 16 QAM .........9-147
C372490158 Number of Received ACK for a given TBS - HSDPA QPSK...............9-148
C372490159 Number of Received NACK for a given TBS - HSDPA QPSK ............9-149
C372490160 Number of Received NACK - HSDPA ................................................9-150
C372490161 Number of Received ACK - HSDPA...................................................9-150
C372490162 Number of Received DTX - HSDPA...................................................9-151
C372490163 NACK rate - HSDPA..........................................................................9-152
C372490164 Number of ResBler - HSDPA.............................................................9-153
C372490165 Number of ResBler - HSDPA.............................................................9-154
9-4
SJ-20100510160815-008|2011-01-04(R5.0)
9-5
SJ-20100510160815-008|2011-01-04(R5.0)
9-6
SJ-20100510160815-008|2011-01-04(R5.0)
l
l
l
l
l
Short Form
Maximum_Power_Reserved_to_HSDPA
Sampling Period
15 minutes
Counter Type
Maximum value
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the cell power is changed or a new cell is set up each time
Description
Maximum power reserved to HSDPA.That is,the power used during the HSDPA scheduling
can not exceed the maximum value.
Updates
Once the cell power is changed or a new cell is set up each time, this value is recalculated.
Short Form
HSDPA_Maximum_Power
Sampling Period
15 minutes
Counter Type
Maximum value
9-8
SJ-20100510160815-008|2011-01-04(R5.0)
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the current maximum power value used by the HSDPA shceduling is different from
that of the previous scheduling.
Description
HSDPA maximum power.That is,in a sampling period,the current value at the scheduling
time is compared with the previous value and always takes the larger one.
Updates
In a sampling period, once the power value at the scheduling time is larger than ever, it
replaces the new value for that of HSDPA maximum power.
Short Form
HSDPA_Minimum_Power
Sampling Period
15 minutes
Counter Type
Minimum value
Unit
times
Measurement Object
DPA Cell
9-9
SJ-20100510160815-008|2011-01-04(R5.0)
Sampling Point
When the current maximum power value used by the HSDPA shceduling is different from
the previous maximum power value.
Description
HSDPA minimum power.That is,in a sampling period,the current value at the scheduling
time is compared with the previous value and always takes the smaller one.
Updates
In a sampling period, once the power value at the scheduling time is smaller than ever,
this counter replaces the new value for that of HSDPA minimum power.
Short Form
HSDPA_Average_Power
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
DPA Cell
Sampling Point
The value of HSDPA power used and the number of scheduling TTI.
Description
The average value of power used during the HSDPA scheduling.process in a sampling
period
9-10
SJ-20100510160815-008|2011-01-04(R5.0)
Updates
This counter adds the values of power that each TTI with the sheduling uses, and divides
by the numnber of TTI with the scheduling. The result is the average value.
Short Form
HSDPA_DL_Power_Distribution_inf_31dbm
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the value of power used during the scheduling process is smaller than or equal to
31dbm.
Description
The number of power used that the value of power is smaller than or equal to 31dbm during
the HSDPA scheduling process in a sampling period.
Updates
In a sampling period, once the value of the power used during the scheduling process is
smaller than or equal to 31dbm, the counter increases by 1.
9-11
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSDPA_DL_Power_Distribution_31dbm_32dbm
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the value of power used during the scheduling process is larger than 31dbm and
smaller than or equal to 32dbm.
Description
The number of power used that the value of power is larger than 31dbm and equal to or
smaller than 32dbm during the HSDPA scheduling in a sampling period.
Updates
In a sampling period, once the value of the power used during the scheduling process is
larger than 31dbm and equal to or smaller than 32dbm, the counter increases by 1.
9-12
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSDPA_DL_Power_Distribution_32dbm_33dbm
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the value of power used during the scheduling process is larger than 32dbm and
smaller than or equal to 33dbm.
Description
The number of power used that the value of power is larger than 32dbm and equal to or
smaller than 33dbm during the HSDPA scheduling in a sampling period.
Updates
In a sampling period, once the value of the power used during the scheduling process is
larger than 32dbm and equal to or smaller than 33dbm, the counter increases by 1.
9-13
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSDPA_DL_Power_Distribution_33dbm_34dbm
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the value of power used during the scheduling process is larger than 33dbm and
smaller than or equal to 34dbm.
Description
The number of power used that the value of power is larger than 33dbm and equal to or
smaller than 34dbm during the HSDPA scheduling in a sampling period.
Updates
In a sampling period, once the value of the power used during the scheduling process is
larger than 33dbm and equal to or smaller than 34dbm, the counter increases by 1.
9-14
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSDPA_DL_Power_Distribution_34dbm_35dbm
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the value of power used during the scheduling process is larger than 34dbm and
smaller than or equal to 35dbm.
Description
The number of power used that the value of power is larger than 34dbm and equal to or
smaller than 35dbm during the HSDPA scheduling in a sampling period.
Updates
In a sampling period, once the value of the power used during the scheduling process is
larger than 34dbm and equal to or smaller than 35dbm, the counter increases by 1.
9-15
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSDPA_DL_Power_Distribution_35dbm_36dbm
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the value of power used during the scheduling process is larger than 35dbm and
smaller than or equal to 36dbm.
Description
The number of power used that the value of power is larger than 35dbm and equal to or
smaller than 36dbm during the HSDPA scheduling in a sampling period.
Updates
In a sampling period, once the value of the power used during the scheduling process is
larger than 35dbm and equal to or smaller than 36dbm, the counter increases by 1.
9-16
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSDPA_DL_Power_Distribution_36dbm_37dbm
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the value of power used during the scheduling process is larger than 36dbm and
smaller than or equal to 37dbm.
Description
The number of power used that the value of power is larger than 36dbm and equal to or
smaller than 37dbm during the HSDPA scheduling in a sampling period.
Updates
n a sampling period, once the value of the power used during the scheduling process is
larger than 36dbm and equal to or smaller than 37dbm, the counter increases by 1.
9-17
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSDPA_DL_Power_Distribution_37dbm_38dbm
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the value of power used during the scheduling process is larger than 37dbm and
smaller than or equal to 38dbm.
Description
The number of power used that the value of power is larger than 37dbm and equal to or
smaller than 38dbm during the HSDPA scheduling in a sampling period.
Updates
In a sampling period, once the value of the power used during the scheduling process is
larger than 37dbm and equal to or smaller than 38dbm, the counter increases by 1.
9-18
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSDPA_DL_Power_Distribution_38dbm_39dbm
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the value of power used during the scheduling process is larger than 38dbm and
smaller than or equal to 39dbm.
Description
The number of power used that the value of power is larger than 38dbm and equal to or
smaller than 39dbm during the HSDPA scheduling in a sampling period.
Updates
In a sampling period, once the value of the power used during the scheduling process is
larger than 38dbm and equal to or smaller than 39dbm, the counter increases by 1.
9-19
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSDPA_DL_Power_Distribution_39dbm_40dbm
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the value of power used during the scheduling process is larger than 39dbm and
smaller than or equal to 40dbm.
Description
The number of power used that the value of power is larger than 39dbm and equal to or
smaller than 40dbm during the HSDPA scheduling in a sampling period.
Updates
In a sampling period, once the value of the power used during the scheduling process is
larger than 39dbm and equal to or smaller than 40dbm, the counter increases by 1.
9-20
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSDPA_DL_Power_Distribution_40dbm_41dbm
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the value of power used during the scheduling process is larger than 40dbm and
smaller than or equal to 41dbm.
Description
The number of power used that the value of power is larger than 40dbm and equal to or
smaller than 41dbm during the HSDPA scheduling in a sampling period.
Updates
In a sampling period, once the value of the power used during the scheduling process is
larger than 40dbm and equal to or smaller than 41dbm, the counter increases by 1.
9-21
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSDPA_DL_Power_Distribution_41dbm_42dbm
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the value of power used during the scheduling process is larger than 41dbm and
smaller than or equal to 42dbm.
Description
The number of power used that the value of power is larger than 41dbm and equal to or
smaller than 42dbm during the HSDPA scheduling in a sampling period.
Updates
In a sampling period, once the value of the power used during the scheduling process is
larger than 41dbm and equal to or smaller than 42dbm, the counter increases by 1.
9-22
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSDPA_DL_Power_Distribution_42dbm_43dbm
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the value of power used during the scheduling process is larger than 42dbm and
smaller than or equal to 43dbm.
Description
The number of power used that the value of power is larger than 42dbm and equal to or
smaller than 43dbm during the HSDPA scheduling in a sampling period.
Updates
In a sampling period, once the value of the power used during the scheduling process is
larger than 42dbm and equal to or smaller than 43dbm, the counter increases by 1.
9-23
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSDPA_DL_Power_Distribution_43dbm_44dbm
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the value of power used during the scheduling process is larger than 43dbm and
smaller than or equal to 44dbm.
Description
The number of power used that the value of power is larger than 43dbm and equal to or
smaller than 44dbm during the HSDPA scheduling in a sampling period.
Updates
In a sampling period, once the value of the power used during the scheduling process is
larger than 43dbm and equal to or smaller than 44dbm, the counter increases by 1.
9-24
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSDPA_DL_Power_Distribution_44dbm_45dbm
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the value of power used during the scheduling process is larger than 44dbm and
smaller than or equal to 45dbm.
Description
The number of power used that the value of power is larger than 44dbm and equal to or
smaller than 45dbm during the HSDPA scheduling in a sampling period.
Updates
In a sampling period, once the value of the power used during the scheduling process is
larger than 44dbm and equal to or smaller than 45dbm, the counter increases by 1.
Short Form
HSDPA_DL_Power_Distribution_45dbm_inf
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the value of power used during the scheduling process is larger than 45dbm.
Description
The number of power used that the value of power is larger than 45dbm during the HSDPA
scheduling in a sampling period.
Updates
In a sampling period, once the value of the power used during the scheduling process is
larger than 45dbm, the counter increases by 1.
Short Form
HSPA_Radio_Load_Downlink
Sampling Period
15 minutes
9-26
SJ-20100510160815-008|2011-01-04(R5.0)
Counter Type
Average Value
Unit
times
Measurement Object
DPA Cell
Sampling Point
The ratio of the average power and the maximum power used during the HSDPA
scheduling process.
Description
The ratio of the average power and the maximum power used during the HSDPA
scheduling process in a sampling period.
Updates
In a sampling period, once the average power or the maximum power used during the
scheduling changes, the counter is updated.
Short Form
Maximum_Used_Codes_for_HSDPA
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
9-27
SJ-20100510160815-008|2011-01-04(R5.0)
Measurement Object
DPA Cell
Sampling Point
When the number of HS-PDSCH code channels used during the HSDPA scheduling
process is different from the previous numer of code channels.
Description
The maxium number of HS-PDSCH ever used during the HSDPA scheduling process in
a sampling period.That is, during each scheduling process,the number of PDSCH used
is compared with the previous value and always take the larger one. If a TTI is not with
sheduling,the TTI is not calculated.
Updates
During each scheduling process, the number of PDSCH code channels is compared with
the previous value and always takes the larger one, and the counter is updated. If a TTI
is not with scheduling, the TTIi is not calculated.
Short Form
Minimum_Used_Codes_for_HSDPA
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
9-28
SJ-20100510160815-008|2011-01-04(R5.0)
Sampling Point
When the number of HS-PDSCH code channels used during the HSDPA scheduling
process is different from the previous numer of code channels
Description
The minimum number of HS-PDSCH ever used during the HSDPA scheduling process in
a sampling period.That is, during each scheduling process,the number of PDSCH used is
compared with the previous value and always take the smaller one. If a TTI is not with
sheduling,the TTI is not calculated.
Updates
During each scheduling process, the number of PDSCH code channels is compared with
the previous value and always takes the smaller one, and the counter is updated. If a TTI
is not with scheduling, the TTIi is not calculated.
Short Form
Average_Used_Codes_for_HSDPA
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
9-29
SJ-20100510160815-008|2011-01-04(R5.0)
Sampling Point
The number of TTI with the sheduling and the number of HS-PDSCH used by each TTI
during the sheduling process adds the number of HS-PDSCH used by each TTI, and then
divides by the number of TTI with the shceduling.
Description
The average numer of HS-PDSCH code channels used during the HSDPA shceduling
process in a sampling period adds the number of HS-PDSCH code channels used by each
TTI, and divides by the number of TTI with the scheduling.
Updates
During each TTI scheduling, the number of HSPDSCH code channels adds the number
of HS-PDSCH code channels used by the TTI, and divides by the number of the TTI with
the scheduling.
Short Form
Number_of_Code_Used_for_HSDPA
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
The number of TTI with the sheduling.
9-30
SJ-20100510160815-008|2011-01-04(R5.0)
Description
The counter adds the number of HSPDSCH code channels used by each TTI with the
scheduling in a sampling period.
Updates
In a sampling period, the number of HSPDSCH code channels is added with the TTI
scheduling, the value of the counter increases with the increase of the scheduling time.
Short Form
Number_of_Reported_CQI_0
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 0.
Description
The number of reported that the CQI is reported as 0 during the non-MMO double current
scheduling in a sampling period(MMO single current or common user).
Updates
In a sampling period, once the CQI is reported as 0, the counter increases by 1.
9-31
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_Reported_CQI_1
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 1.
Description
The number of reported that CQI is reported as 1 during the non-MMO double current
scheduling in a sampling period(MMO single current or common user).
Updates
In a sampling period, once the CQI is reported as 1, the counter increases by 1.
Short Form
Number_of_Reported_CQI_2
9-32
SJ-20100510160815-008|2011-01-04(R5.0)
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 2.
Description
The number of reported that the CQI is reported as 2 during the non-MMO double current
scheduling in a sampling period(MMO single current or common user).
Updates
In a sampling period, once the CQI is reported as 2, the counter increases by 1.
Short Form
Number_of_Reported_CQI_3
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
9-33
SJ-20100510160815-008|2011-01-04(R5.0)
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 3.
Description
The number of reported that the CQI is reported as 3 during the non-MMO double current
scheduling in a sampling period(MMO single current or common user).
Updates
In a sampling period, once the CQI is reported as 3, the counter increases by 1.
Short Form
Number_of_Reported_CQI_4
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 4.
9-34
SJ-20100510160815-008|2011-01-04(R5.0)
Description
The number of reported that the CQI is reported as 4 during the non-MMO double current
scheduling in a sampling period(MMO single current or common user).
Updates
In a sampling period, once the CQI is reported as 4, the counter increases by 1.
Short Form
Number_of_Reported_CQI_5
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 5.
Description
The number of reported that the CQI is reported as 5 during the non-MMO double current
scheduling in a sampling period(MMO single current or common user).
Updates
In a sampling period, once the CQI is reported as 5, the counter increases by 1.
9-35
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_Reported_CQI_6
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 6.
Description
The number of reported that the CQI is reported as 6 during the non-MMO double current
scheduling in a sampling period(MMO single current or common user).
Updates
In a sampling period, once the CQI is reported as 6, the counter increases by 1.
Short Form
Number_of_Reported_CQI_7
9-36
SJ-20100510160815-008|2011-01-04(R5.0)
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 7.
Description
The number of reported that the CQI is reported as 7 during the non-MMO double current
scheduling in a sampling period(MMO single current or common user).
Updates
In a sampling period, once the CQI is reported as 7, the counter increases by 1.
Short Form
Number_of_Reported_CQI_8
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
9-37
SJ-20100510160815-008|2011-01-04(R5.0)
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 8.
Description
The number of reported that the CQI is reported as 8 during the non-MMO double current
scheduling in a sampling period(MMO single current or common user).
Updates
In a sampling period, once the CQI is reported as 8, the counter increases by 1.
Short Form
Number_of_Reported_CQI_9
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 9.
9-38
SJ-20100510160815-008|2011-01-04(R5.0)
Description
The number of reported that the CQI is reported as 9 during the non-MMO double current
scheduling in a sampling period(MMO single current or common user).
Updates
In a sampling period, once the CQI is reported as 9, the counter increases by 1.
Short Form
Number_of_Reported_CQI_10
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 10.
Description
The number of reported that the CQI is reported as 10 during the non-MMO double current
scheduling in a sampling period(MMO single current or common user).
Updates
In a sampling period, once the CQI is reported as 10, the counter increases by 1.
9-39
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_Reported_CQI_11
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 11.
Description
The number of reported that the CQI is reported as 11 during the non-MMO double current
scheduling in a sampling period(MMO single current or common user).
Updates
In a sampling period, once the CQI is reported as 11, the counter increases by 1.
Short Form
Number_of_Reported_CQI_12
9-40
SJ-20100510160815-008|2011-01-04(R5.0)
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 12.
Description
The number of reported that the CQI is reported as 12 during the non-MMO double current
scheduling in a sampling period(MMO single current or common user).
Updates
In a sampling period, once the CQI is reported as 12, the counter increases by 1.
Short Form
Number_of_Reported_CQI_13
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
9-41
SJ-20100510160815-008|2011-01-04(R5.0)
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 13.
Description
The number of reported that the CQI is reported as 13 during the non-MMO double current
scheduling in a sampling period(MMO single current or common user).
Updates
In a sampling period, once the CQI is reported as 13, the counter increases by 1.
Short Form
Number_of_Reported_CQI_14
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 14.
9-42
SJ-20100510160815-008|2011-01-04(R5.0)
Description
The number of reported that the CQI is reported as 14 during the non-MMO double current
scheduling in a sampling period(MMO single current or common user).
Updates
In a sampling period, once the CQI is reported as 14, the counter increases by 1.
Short Form
Number_of_Reported_CQI_15
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 15.
Description
The number of reported that the CQI is reported as 15 during the non-MMO double current
scheduling in a sampling period(MMO single current or common user).
Updates
In a sampling period, once the CQI is reported as 15, the counter increases by 1.
9-43
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_Reported_CQI_16
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 16.
Description
The number of reported that the CQI is reported as 16 during the non-MMO double current
scheduling in a sampling period(MMO single current or common user).
Updates
In a sampling period, once the CQI is reported as 16, the counter increases by 1.
Short Form
Number_of_Reported_CQI_17
9-44
SJ-20100510160815-008|2011-01-04(R5.0)
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 17.
Description
The number of reported that the CQI is reported as 17 during the non-MMO double current
scheduling in a sampling period(MMO single current or common user).
Updates
In a sampling period, once the CQI is reported as 17, the counter increases by 1.
Short Form
Number_of_Reported_CQI_18
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
9-45
SJ-20100510160815-008|2011-01-04(R5.0)
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 18.
Description
The number of reported that the CQI is reported as 18 during the non-MMO double current
scheduling in a sampling period(MMO single current or common user).
Updates
In a sampling period, once the CQI is reported as 18, the counter increases by 1.
Short Form
Number_of_Reported_CQI_19
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 19.
9-46
SJ-20100510160815-008|2011-01-04(R5.0)
Description
The number of reported that the CQI is reported as 19 during the non-MMO double current
scheduling in a sampling period(MMO single current or common user).
Updates
In a sampling period, once the CQI is reported as 19, the counter increases by 1.
Short Form
Number_of_Reported_CQI_20
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 20.
Description
In a sampling period,the number of reported that the CQI is reported as 20 during the
non-MMO double current scheduling(MMO single current or common user).
Updates
In a sampling period, once the CQI is reported as 20, the counter increases by 1.
9-47
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_Reported_CQI_21
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 21.
Description
The number of reported that the CQI is reported as 21 during the non-MMO double current
scheduling in a sampling period(MMO single current or common user).
Updates
In a sampling period, once the CQI is reported as 21, the counter increases by 1.
Short Form
Number_of_Reported_CQI_22
9-48
SJ-20100510160815-008|2011-01-04(R5.0)
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 22.
Description
The number of reported that the CQI is reported as 22 during the non-MMO double current
scheduling in a sampling period(MMO single current or common user).
Updates
In a sampling period, once the CQI is reported as 22, the counter increases by 1.
Short Form
Number_of_Reported_CQI_23
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
9-49
SJ-20100510160815-008|2011-01-04(R5.0)
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 23.
Description
The number of reported that the CQI is reported as 23 during the non-MMO double current
scheduling in a sampling period(MMO single current or common user).
Updates
In a sampling period, once the CQI is reported as 23, the counter increases by 1.
Short Form
Number_of_Reported_CQI_24
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 24.
9-50
SJ-20100510160815-008|2011-01-04(R5.0)
Description
The number of reported that the CQI is reported as 24 during the non-MMO double current
scheduling in a sampling period(MMO single current or common user).
Updates
In a sampling period, once the CQI is reported as 24, the counter increases by 1.
Short Form
Number_of_Reported_CQI_25
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 25.
Description
The number of reported that the CQI is reported as 25 during the non-MMO double current
scheduling in a sampling period(MMO single current or common user).
Updates
In a sampling period, once the CQI is reported as 25, the counter increases by 1.
9-51
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_Reported_CQI_26
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 26.
Description
The number of reported that the CQI is reported as 26 during the non-MMO double current
scheduling in a sampling period(MMO single current or common user).
Updates
In a sampling period, once the CQI is reported as 26, the counter increases by 1.
Short Form
Number_of_Reported_CQI_27
9-52
SJ-20100510160815-008|2011-01-04(R5.0)
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 27.
Description
The number of reported that the CQI is reported as 27 during the non-MMO double current
scheduling in a sampling period(MMO single current or common user).
Updates
In a sampling period, once the CQI is reported as 27, the counter increases by 1.
Short Form
Number_of_Reported_CQI_28
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
9-53
SJ-20100510160815-008|2011-01-04(R5.0)
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 28.
Description
The number of reported that the CQI is reported as 28 during the non-MMO double current
scheduling in a sampling period(MMO single current or common user).
Updates
In a sampling period, once the CQI is reported as 28, the counter increases by 1.
Short Form
Number_of_Reported_CQI_29
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 29.
9-54
SJ-20100510160815-008|2011-01-04(R5.0)
Description
The number of reported that the CQI is reported as 29 during the non-MMO double current
scheduling in a sampling period(MMO single current or common user).
Updates
In a sampling period, once the CQI is reported as 29, the counter increases by 1.
Short Form
Number_of_Reported_CQI_30
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 30.
Description
The number of reported that the CQI is reported as 30 during the non-MMO double current
scheduling in a sampling period(MMO single current or common user).
Updates
In a sampling period, once the CQI is reported as 30, the counter increases by 1.
9-55
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSDPA_Average_Reported_CQI
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the communication quality indicator of radio channels changes
Description
In a sampling period,the average value of reported that CQI is reported by the UE during
the non-MMO double current scheduling(MMO single current or common user).That is,
the counter adds the values of all reported non-MMO double current CQI used for the
scheduling and then divides by the number of UE reports
Updates
Once the radio channel quality changes, adds the values of all reported non-MIMO double
current CQI, and divides by the number of UE reports.
9-56
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_Reported_CQI_0_while_MIMO_TwoStream
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 0.
Description
The number of reported that the CQI is reported as 0 during the MIMO double current
scheduling in a sampling period.
Updates
In a sampling period, once the CQI is reported as 0, the counter increases by 1.
Short Form
Number_of_Reported_CQI_1_while_MIMO_TwoStream
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 1.
Description
The number of reported that the CQI reported as 1 during the MIMO double current
scheduling in a sampling period.
Updates
In a sampling period, once the CQI is reported as 1, the counter increases by 1.
Short Form
Number_of_Reported_CQI_2_while_MIMO_TwoStream
Sampling Period
15 minutes
9-58
SJ-20100510160815-008|2011-01-04(R5.0)
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 2.
Description
The number of reported that the CQI is reported as 2 during the MIMO double current
scheduling in a sampling period.
Updates
In a sampling period, once the CQI is reported as 2, the counter increases by 1.
Short Form
Number_of_Reported_CQI_3_while_MIMO_TwoStream
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
9-59
SJ-20100510160815-008|2011-01-04(R5.0)
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 3.
Description
The number of reported that the CQI is reported as 3 during the MIMO double current
scheduling in a sampling period.
Updates
In a sampling period, once the CQI is reported as 3, the counter increases by 1.
Short Form
Number_of_Reported_CQI_4_while_MIMO_TwoStream
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 4.
9-60
SJ-20100510160815-008|2011-01-04(R5.0)
Description
The number of reported that the CQI is reported as 4 during the MIMO double current
scheduling in a sampling period.
Updates
In a sampling period, once the CQI is reported as 4, the counter increases by 1.
Short Form
Number_of_Reported_CQI_5_while_MIMO_TwoStream
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 5.
Description
The number of reported that the CQI is reported as 5 during the MIMO double current
scheduling in a sampling period.
Updates
In a sampling period, once the CQI is reported as 5, the counter increases by 1.
9-61
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_Reported_CQI_6_while_MIMO_TwoStream
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 6.
Description
The number of reported that the CQI is reported as 6 during the MIMO double current
scheduling in a sampling period.
Updates
In a sampling period, once the CQI is reported as 6, the counter increases by 1.
Short Form
Number_of_Reported_CQI_7_while_MIMO_TwoStream
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 7.
Description
The number of the CQI reported as 7 during the MIMO double current scheduling in a
sampling period.
Updates
In a sampling period, once the CQI is reported as 7, the counter increases by 1.
Short Form
Number_of_Reported_CQI_8_while_MIMO_TwoStream
Sampling Period
15 minutes
9-63
SJ-20100510160815-008|2011-01-04(R5.0)
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 8.
Description
The number of reported that the CQI is reported as 8 during the MIMO double current
scheduling in a sampling period.
Updates
In a sampling period, once the CQI is reported as 8, the counter increases by 1.
Short Form
Number_of_Reported_CQI_9while_MIMO_TwoStream
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
9-64
SJ-20100510160815-008|2011-01-04(R5.0)
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 9.
Description
The number of reported that the CQI is reported as 9 during the MIMO double current
scheduling in a sampling period.
Updates
In a sampling period, once the CQI is reported as 9, the counter increases by 1.
Short Form
Number_of_Reported_CQI_10_while_MIMO_TwoStream
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 10.
9-65
SJ-20100510160815-008|2011-01-04(R5.0)
Description
The number of reported that the CQI is reported as 10 during the MIMO double current
scheduling in a sampling period.
Updates
In a sampling period, once the CQI is reported as 10, the counter increases by 1.
Short Form
Number_of_Reported_CQI_11_while_MIMO_TwoStream
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 11.
Description
The number of reported that the CQI is reported as 11 during the MIMO double current
scheduling in a sampling period.
Updates
In a sampling period, once the CQI is reported as 11, the counter increases by 1.
9-66
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_Reported_CQI_12_while_MIMO_TwoStream
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 12.
Description
The number of reported that the CQI is reported as 12 during the MIMO double current
scheduling in a sampling period.
Updates
In a sampling period, once the CQI is reported as 12, the counter increases by 1.
Short Form
Number_of_Reported_CQI_13_while_MIMO_TwoStream
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 13.
Description
The number of reported that the CQI is reported as 13 during the MIMO double current
scheduling in a sampling period.
Updates
In a sampling period, once the CQI is reported as 13, the counter increases by 1.
Short Form
Number_of_Reported_CQI_14_while_MIMO_TwoStream
Sampling Period
15 minutes
9-68
SJ-20100510160815-008|2011-01-04(R5.0)
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the CQI(channel quality indicator) is 14.
Description
The number of reported that the CQI is reported as 14 during the MIMO double current
scheduling in a sampling period.
Updates
In a sampling period, once the CQI is reported as 14, the counter increases by 1.
Short Form
HSDPA_Average_Reported_CQI_while_MIMO_TwoStream
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
9-69
SJ-20100510160815-008|2011-01-04(R5.0)
Measurement Object
DPA Cell
Sampling Point
When the communication quality indicator of radio channels changes
Description
In a sampling period,the average value of the CQI is reported by the UE during the MMO
double current scheduling.That is,the counter adds the values of all reported MMO double
current CQI used for the scheduling and then divides by the number of UE reports.
Updates
Once the radio channel quality changes, adds the values of all reported non-MIMO double
current CQI, and divides by the number of UE reports.
Short Form
CQI_failure
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
9-70
SJ-20100510160815-008|2011-01-04(R5.0)
Sampling Point
Once the channel quality indicator is reported by the uplink by mistake,the CQI is reported
larger than 30 in the case of common UE and the CQI is reported larger than 30 (CQI type
is TYPEB) in the case of MIMO UE.
Description
UE reports the CQI by mistake.It includes the CQI is reported larger than 30 in the case
of common UE and the CQI is reported larger than 30(CQI type is typeB) in the case of
MIMO UE,the counter increases by 1.
Updates
In a sampling period, once the CQI is reported larger than 30 in the case of common UE or
the CQI is reported larger than 30(CQI type is typeB) in the case of MIMO UE,the counter
increases by 1.
Short Form
Number_of_Used_CQI_0
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the non-MIMO dual current schedules with CQI=0.
9-71
SJ-20100510160815-008|2011-01-04(R5.0)
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the non-MIMO double current (MIMO single current or common user) is 0 in a sampling
period.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 0.
Short Form
Number_of_Used_CQI_1
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the non-MIMO dual current schedules with CQI=1.
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the non-MIMO double current (MIMO single current or common user) is 1 in a sampling
period.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 1.
9-72
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_Used_CQI_2
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the non-MIMO dual current schedules with CQI=2.
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the non-MIMO double current (MIMO single current or common user) is 2 in a sampling
period.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 2.
Short Form
Number_of_Used_CQI_3
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the non-MIMO dual current schedules with CQI=3.
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the non-MIMO double current (MIMO single current or common user) is 3 in a sampling
period.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 3.
Short Form
Number_of_Used_CQI_4
Sampling Period
15 minutes
9-74
SJ-20100510160815-008|2011-01-04(R5.0)
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the non-MIMO dual current schedules with CQI=4.
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the non-MIMO double current (MIMO single current or common user) is 4 in a sampling
period.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 4.
Short Form
Number_of_Used_CQI_5
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
9-75
SJ-20100510160815-008|2011-01-04(R5.0)
Measurement Object
DPA Cell
Sampling Point
When the non-MIMO dual current schedules with CQI=5.
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the non-MIMO double current (MIMO single current or common user) is 5 in a sampling
period.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 5.
Short Form
Number_of_Used_CQI_6
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the non-MIMO dual current schedules with CQI=6.
9-76
SJ-20100510160815-008|2011-01-04(R5.0)
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the non-MIMO double current (MIMO single current or common user) is 6 in a sampling
period.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 6.
Short Form
Number_of_Used_CQI_7
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the non-MIMO dual current schedules with CQI=7.
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the non-MIMO double current (MIMO single current or common user) is 7 in a sampling
period.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 7.
9-77
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_Used_CQI_8
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the non-MIMO dual current schedules with CQI=8.
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the non-MIMO double current (MIMO single current or common user) is 8 in a sampling
period.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 8.
Short Form
Number_of_Used_CQI_9
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the non-MIMO dual current schedules with CQI=9.
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the non-MIMO double current (MIMO single current or common user) is 9 in a sampling
period.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 9.
Short Form
Number_of_Used_CQI_10
Sampling Period
15 minutes
9-79
SJ-20100510160815-008|2011-01-04(R5.0)
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the non-MIMO dual current schedules with CQI=10.
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the non-MIMO double current (MIMO single current or common user) is 10 in a sampling
period.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 10.
Short Form
Number_of_Used_CQI_11
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
9-80
SJ-20100510160815-008|2011-01-04(R5.0)
Measurement Object
DPA Cell
Sampling Point
When the non-MIMO dual current schedules with CQI=11.
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the non-MIMO double current (MIMO single current or common user) is 11 in a sampling
period.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 11.
Short Form
Number_of_Used_CQI_12
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the non-MIMO dual current schedules with CQI=12.
9-81
SJ-20100510160815-008|2011-01-04(R5.0)
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the non-MIMO double current (MIMO single current or common user) is 12 in a sampling
period.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 12.
Short Form
Number_of_Used_CQI_13
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the non-MIMO dual current schedules with CQI=13.
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the non-MIMO double current (MIMO single current or common user) is 13 in a sampling
period.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 13.
9-82
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_Used_CQI_14
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the non-MIMO dual current schedules with CQI=14.
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the non-MIMO double current (MIMO single current or common user) is 14 in a sampling
period.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 14.
Short Form
Number_of_Used_CQI_15
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the non-MIMO dual current schedules with CQI=15.
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the non-MIMO double current (MIMO single current or common user) is 15 in a sampling
period.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 15.
Short Form
Number_of_Used_CQI_16
Sampling Period
15 minutes
9-84
SJ-20100510160815-008|2011-01-04(R5.0)
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the non-MIMO dual current schedules with CQI=16.
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the non-MIMO double current (MIMO single current or common user) is 16 in a sampling
period.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 16.
Short Form
Number_of_Used_CQI_17
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
9-85
SJ-20100510160815-008|2011-01-04(R5.0)
Measurement Object
DPA Cell
Sampling Point
When the non-MIMO dual current schedules with CQI=17.
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the non-MIMO double current (MIMO single current or common user) is 17 in a sampling
period.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 17.
Short Form
Number_of_Used_CQI_18
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the non-MIMO dual current schedules with CQI=18.
9-86
SJ-20100510160815-008|2011-01-04(R5.0)
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the non-MIMO double current (MIMO single current or common user) is 18 in a sampling
period.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 18.
Short Form
Number_of_Used_CQI_19
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the non-MIMO dual current schedules with CQI=19.
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the non-MIMO double current (MIMO single current or common user) is 19 in a sampling
period.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 19.
9-87
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_Used_CQI_20
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the non-MIMO dual current schedules with CQI=20.
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the non-MIMO double current (MIMO single current or common user) is 20 in a sampling
period.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 20.
Short Form
Number_of_Used_CQI_21
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the non-MIMO dual current schedules with CQI=21.
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the non-MIMO double current (MIMO single current or common user) is 21 in a sampling
period.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 21.
Short Form
Number_of_Used_CQI_22
Sampling Period
15 minutes
9-89
SJ-20100510160815-008|2011-01-04(R5.0)
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the non-MIMO dual current schedules with CQI=22.
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the non-MIMO double current (MIMO single current or common user) is 22 in a sampling
period.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 22.
Short Form
Number_of_Used_CQI_23
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
9-90
SJ-20100510160815-008|2011-01-04(R5.0)
Measurement Object
DPA Cell
Sampling Point
When the non-MIMO dual current schedules with CQI=23.
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the non-MIMO double current (MIMO single current or common user) is 23 in a sampling
period.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 23.
Short Form
Number_of_Used_CQI_24
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the non-MIMO dual current schedules with CQI=24.
9-91
SJ-20100510160815-008|2011-01-04(R5.0)
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the non-MIMO double current (MIMO single current or common user) is 24 in a sampling
period.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 24.
Short Form
Number_of_Used_CQI_25
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the non-MIMO dual current schedules with CQI=25.
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the non-MIMO double current (MIMO single current or common user) is 25 in a sampling
period.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 25.
9-92
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_Used_CQI_26
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the non-MIMO dual current schedules with CQI=26.
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the non-MIMO double current (MIMO single current or common user) is 26 in a sampling
period.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 26.
Short Form
Number_of_Used_CQI_27
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the non-MIMO dual current schedules with CQI=27.
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the non-MIMO double current (MIMO single current or common user) is 27 in a sampling
period.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 27.
Short Form
Number_of_Used_CQI_28
Sampling Period
15 minutes
9-94
SJ-20100510160815-008|2011-01-04(R5.0)
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the non-MIMO dual current schedules with CQI=28.
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the non-MIMO double current (MIMO single current or common user) is 28 in a sampling
period.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 28.
Short Form
Number_of_Used_CQI_29
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
9-95
SJ-20100510160815-008|2011-01-04(R5.0)
Measurement Object
DPA Cell
Sampling Point
When the non-MIMO dual current schedules with CQI=29.
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the non-MIMO double current (MIMO single current or common user) is 29 in a sampling
period.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 29.
Short Form
Number_of_Used_CQI_30
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the non-MIMO dual current schedules with CQI=30.
9-96
SJ-20100510160815-008|2011-01-04(R5.0)
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the non-MIMO double current (MIMO single current or common user) is 30 in a sampling
period.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 30.
Short Form
HSDPA_Average_Used_CQI
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the scheduling indication or the radio channel quality indication changes, or when
the CQI value for the sheduling changes.
Description
This counter indicates the average value of the CQI used for the schedule during the
non-MIMO double current scheduling (MIMO single current or common user) in the
sampling period. That is, the Node B adds the values of all non-MIMO dual current CQI
used for the schedule and then divides by the number of times that the UE schedules.
9-97
SJ-20100510160815-008|2011-01-04(R5.0)
Updates
The counter is updated when the channel quality indication changes or the CQI changes.
The Node B adds the values of all used non-MIMO dual current CQI and then divides by
the number of times that the UE schedules.
Short Form
Number_of_Used_CQI_0_while_MIMO_Two_Stream
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the MIMO dual current schedules with CQI=0.
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the MIMO double current is 0.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 0.
9-98
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_Used_CQI_1_while_MIMO_Two_Stream
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the MIMO dual current schedules with CQI=1.
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the MIMO double current is 1.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 1.
9-99
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_Used_CQI_2_while_MIMO_Two_Stream
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the MIMO dual current schedules with CQI=2.
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the MIMO double current is 2.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 2.
9-100
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_Used_CQI_3_while_MIMO_Two_Stream
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the MIMO dual current schedules with CQI=3.
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the MIMO double current is 3.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 3.
9-101
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_Used_CQI_4_while_MIMO_Two_Stream
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the MIMO dual current schedules with CQI=4.
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the MIMO double current is 4.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 4.
9-102
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_Used_CQI_5_while_MIMO_Two_Stream
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the MIMO dual current schedules with CQI=5.
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the MIMO double current is 5.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 5.
9-103
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_Used_CQI_6_while_MIMO_Two_Stream
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the MIMO dual current schedules with CQI=6.
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the MIMO double current is 6.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 6.
9-104
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_Used_CQI_7_while_MIMO_Two_Stream
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the MIMO dual current schedules with CQI=7.
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the MIMO double current is 7.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 7.
9-105
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_Used_CQI_8_while_MIMO_Two_Stream
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the MIMO dual current schedules with CQI=8.
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the MIMO double current is 8.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 8.
9-106
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_Used_CQI_9_while_MIMO_Two_Stream
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the MIMO dual current schedules with CQI=9.
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the MIMO double current is 9.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 9.
9-107
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_Used_CQI_10_while_MIMO_Two_Stream
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the MIMO dual current schedules with CQI=10.
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the MIMO double current is 10.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 10.
9-108
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_Used_CQI_11_while_MIMO_Two_Stream
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the MIMO dual current schedules with CQI=11.
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the MIMO double current is 11.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 11.
9-109
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_Used_CQI_12_while_MIMO_Two_Stream
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the MIMO dual current schedules with CQI=12.
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the MIMO double current is 12.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 12.
9-110
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_Used_CQI_13_while_MIMO_Two_Stream
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the MIMO dual current schedules with CQI=13.
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the MIMO double current is 13.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 13.
9-111
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_Used_CQI_14_while_MIMO_Two_Stream
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the MIMO dual current schedules with CQI=14.
Description
This counter indicates the number of times that CQI used for the schedule in the case of
the MIMO double current is 14.
Updates
In a sampling period, the counter increases by 1 when the CQI used for the schedule is 14.
CQI used for the schedule and then divides by the number of times that the UE schedules.
The value reflects the radio channel quality.
Short Form
Average_of_Used_CQI__while_MIMO_Two_StreamI
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the scheduling indication or the radio channel quality indication changes, or when
the CQI value for the sheduling changes.
Description
This counter indicates the average value of the CQI used for the schedule during the MIMO
double current scheduling (MIMO single current or common user) in the sampling period.
That is, the Node B adds the values of all MIMO double current CQI used for the schedule
and then divides by the number of times that the UE schedules.
Updates
The counter is updated when the channel quality indication changes or the CQI changes.
The Node B adds the values of all used non-MIMO dual current CQI and then divides by
the number of times that the UE schedules.
9-113
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSDPA_Traffic_QPSK
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the scheduling is conducted in QPSK modulation.
Description
The counter accumulates TB module sent in the QPSK modulation mode in a sampling
period.
Updates
This counter is updated when the schedule is in QPSK modulation mode and the Node B
adds the TB modules sent in the QPSK modulation mode in a sampling period.
Short Form
HSDPA_Traffic_16QAM
Sampling Period
15 minutes
9-114
SJ-20100510160815-008|2011-01-04(R5.0)
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the scheduling is conducted in 16QAM modulation.
Description
The counter accumulates TB module sent in the 16QAM modulation mode in a sampling
period.
Updates
This counter is updated when the schedule is in 16QAM modulation mode and the Node
B adds the TB modules sent in the 16QAM modulation mode in a sampling period.
Short Form
HSDPA_Traffic_64QAM
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
9-115
SJ-20100510160815-008|2011-01-04(R5.0)
Measurement Object
DPA Cell
Sampling Point
When the scheduling is conducted in 64QAM modulation.
Description
The counter accumulates TB module sent in the 64QAM modulation mode in a sampling
period.
Updates
This counter is updated when the schedule is in 64QAM modulation mode and the Node
B adds the TB modules sent in the 64QAM modulation mode in a sampling period.
Short Form
HSDPA_QPSK_Usage_Ratio
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the modulation mode changes.
9-116
SJ-20100510160815-008|2011-01-04(R5.0)
Description
This counter indicates the percentage of QPSK traffic in a sampling period, that is, the
rate of the total size of TB modules sent in QPSK modulation mode to the total size of TB
modules (sent in QPSK, 16QAM and 64QAM modes).
Updates
This counter indicates the percentage of QPSK traffic in the sampling period, that is, the
proportion of the total size of TB modules sent in QPSK modulation mode and the total
size of TB modules (sent in QPSK, 16QAM and 64QAM modes).
Short Form
HSDPA_16QAM_Usage_Ratio
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the modulation mode changes.
Description
This counter indicates the percentage of 16QAM traffic in a sampling period, that is, the
rate of the total size of TB modules sent in 16QAM modulation mode to the total size of
TB modules (sent in QPSK, 16QAM and 64QAM modes).
9-117
SJ-20100510160815-008|2011-01-04(R5.0)
Updates
This counter indicates the percentage of 16QAM traffic in the sampling period, that is, the
proportion of the total size of TB modules sent in 16QAM modulation mode and the total
size of TB modules (sent in QPSK, 16QAM and 64QAM modes).
Short Form
HSDPA_64QAM_Usage_Ratio
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the modulation mode changes.
Description
This counter indicates the percentage of 64QAM traffic in a sampling period, that is, the
rate of the total size of TB modules sent in 64QAM modulation mode to the total size of
TB modules (sent in QPSK, 16QAM and 64QAM modes).
Updates
This counter indicates the percentage of 64QAM traffic in the sampling period, that is, the
proportion of the total size of TB modules sent in 64QAM modulation mode and the total
size of TB modules (sent in QPSK, 16QAM and 64QAM modes).
9-118
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSDPA_Duration_Activity
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the DPA scheduler has data.
Description
This counter indicates the value that the number of TTI with the schedule times two in a
sampling period. TTI takes the unit of 2 ms.
Updates
In a sampling period, the Node B calculates the number of TTI with the schedule and then
times the value with 2.
Short Form
HSDPA_Average_Throughput_per_user
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the subscribers are scheduled in the object cell.
Description
This counter indicates the number of MAC-d PDU bits that have been scheduled in the
sampling period. That is, the total cell throughput, the number of schedule divided by the
total MAC-D PDU size of the schedule, in the unit of Kbits/s.
Updates
This counter indicates the number of MAC-d PDU bits that have been scheduled in the
sampling period. That is, the total cell throughput, the number of schedule divided by the
total MAC-D PDU size of the schedule, in the unit of Kbits/s.
Short Form
HSDPA_Average_User_Rate_Distribution_0_8_Kbits_per_second
9-120
SJ-20100510160815-008|2011-01-04(R5.0)
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the the average rate in MAC-HS layer is 0-8 Kbits/s.
Description
This counter indicates the number of UE whose rate keeps within 8 Kbits/s in a sampling
period. This counter increases once the rate of the UE keeps within 8 Kbits/s.
Updates
In a sampling period, as long as the rate of the UE keeps 0-8 Kbits/s, the counter increases
by 1.
Short Form
HSDPA_Average_User_Rate_Distribution_8_32Kbps
Sampling Period
15 minutes
Counter Type
Accumulation
9-121
SJ-20100510160815-008|2011-01-04(R5.0)
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the the average rate in MAC-HS layer is 8-32 Kbits/s.
Description
This counter indicates the number of UE whose rate keeps 8-32 Kbits/s. in a sampling
period. This counter increases once the rate of the UE keeps 8-32 Kbits/s.
Updates
This counter counts the subscribers with the average rate of 8-32 Kbits/s in the statistical
process of DPA subscriber rate distribution. This counter is updated when the average
rate of a UE is in this interval.
Short Form
HSDPA_Average_User_Rate_Distribution_32_64Kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
9-122
SJ-20100510160815-008|2011-01-04(R5.0)
Sampling Point
When the the average rate in MAC-HS layer is 32-64 Kbits/s.
Description
This counter indicates the number of UE whose rate keeps 32-64 Kbits/s. in a sampling
period. This counter increases once the rate of the UE keeps 32-64 Kbits/s.
Updates
This counter counts the subscribers with the average rate of 32-64 Kbits/s in the statistical
process of DPA subscriber rate distribution. This counter is updated when the average
rate of a UE is in this interval.
Short Form
HSDPA_Average_User_Rate_Distribution_64_128Kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the the average rate in MAC-HS layer is 64-128 Kbits/s.
9-123
SJ-20100510160815-008|2011-01-04(R5.0)
Description
This counter indicates the number of UE whose rate keeps 64-128 Kbits/s. in a sampling
period. This counter increases once the rate of the UE keeps 64-128 Kbits/s.
Updates
This counter counts the subscribers with the average rate of 64-128 Kbits/s in the statistical
process of DPA subscriber rate distribution. This counter is updated when the average rate
of a UE is in this interval.
Short Form
HSDPA_Average_User_Rate_Distribution_128_256Kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the the average rate in MAC-HS layer is 128-256 Kbits/s.
Description
This counter indicates the number of UE whose rate keeps 128-256 Kbits/s. in a sampling
period. This counter increases once the rate of the UE keeps 128-256 Kbits/s.
9-124
SJ-20100510160815-008|2011-01-04(R5.0)
Updates
This counter counts the subscribers with the average rate of 128-256 Kbits/s in the
statistical process of DPA subscriber rate distribution. This counter is updated when the
average rate of a UE is in this interval.
Short Form
HSDPA_Average_User_Rate_Distribution_256_384Kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the the average rate in MAC-HS layer is 256-384 Kbits/s.
Description
This counter indicates the number of UE whose rate keeps 256-384 Kbits/s. in a sampling
period. This counter increases once the rate of the UE keeps 256-384 Kbits/s.
Updates
This counter counts the subscribers with the average rate of 256-384 Kbits/s in the
statistical process of DPA subscriber rate distribution. This counter is updated when the
average rate of a UE is in this interval.
9-125
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSDPA_Average_User_Rate_Distribution_384_512Kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the the average rate in MAC-HS layer is 0-8 Kbits/s.
Description
This counter indicates the number of UE whose rate keeps 384-512 Kbits/s. in a sampling
period. This counter increases once the rate of the UE keeps 384-512 Kbits/s.
Updates
This counter counts the subscribers with the average rate of 384-512 Kbits/s in the
statistical process of DPA subscriber rate distribution. This counter is updated when the
average rate of a UE is in this interval.
9-126
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSDPA_Average_User_Rate_Distribution_512_768Kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the the average rate in MAC-HS layer is 384-512 Kbits/s.
Description
This counter indicates the number of UE whose rate keeps 512-768 Kbits/s. in a sampling
period. This counter increases once the rate of the UE keeps 512-768 Kbits/s.
Updates
This counter counts the subscribers with the average rate of 512-768 Kbits/s in the
statistical process of DPA subscriber rate distribution. This counter is updated when the
average rate of a UE is in this interval.
9-127
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSDPA_Average_User_Rate_Distribution_768_1024Kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the the average rate in MAC-HS layer is 768-1024 Kbits/s.
Description
This counter indicates the number of UE whose rate keeps 768-1024 Kbits/s. in a sampling
period. This counter increases once the rate of the UE keeps 768-1024 Kbits/s.
Updates
This counter counts the subscribers with the average rate of 768-1024 Kbits/s in the
statistical process of DPA subscriber rate distribution. This counter is updated when the
average rate of a UE is in this interval.
9-128
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSDPA_Average_User_Rate_Distribution_1024_1280Kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the the average rate in MAC-HS layer is 1024-1280 Kbits/s.
Description
This counter indicates the number of UE whose rate keeps 1024-1280 Kbits/s. in a
sampling period. This counter increases once the rate of the UE keeps 1024-1280 Kbits/s.
Updates
This counter counts the subscribers with the average rate of 1024-1280 Kbits/s in the
statistical process of DPA subscriber rate distribution. This counter is updated when the
average rate of a UE is in this interval.
9-129
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSDPA_Average_User_Rate_Distribution_1280_1536Kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the the average rate in MAC-HS layer is 1280-1536 Kbits/s.
Description
This counter indicates the number of UE whose rate keeps 1280-1536 Kbits/s. in a
sampling period. This counter increases once the rate of the UE keeps 1280-1536 Kbits/s.
Updates
This counter counts the subscribers with the average rate of 1280-1536 Kbits/s in the
statistical process of DPA subscriber rate distribution. This counter is updated when the
average rate of a UE is in this interval.
9-130
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSDPA_Average_User_Rate_Distribution_1536_1792Kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the the average rate in MAC-HS layer is 1536-1792 Kbits/s.
Description
This counter indicates the number of UE whose rate keeps 1536-1792 Kbits/s. in a
sampling period. This counter increases once the rate of the UE keeps 1536-1792 Kbits/s.
Updates
This counter counts the subscribers with the average rate of 1536-1792 Kbits/s in the
statistical process of DPA subscriber rate distribution. This counter is updated when the
average rate of a UE is in this interval.
9-131
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSDPA_Average_User_Rate_Distribution_1792_2048Kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the the average rate in MAC-HS layer is 1792-2048 Kbits/s.
Description
This counter indicates the number of UE whose rate keeps 1792-2048 Kbits/s. in a
sampling period. This counter increases once the rate of the UE keeps 1792-2048 Kbits/s.
Updates
This counter counts the subscribers with the average rate of 1792-2048 Kbits/s in the
statistical process of DPA subscriber rate distribution. This counter is updated when the
average rate of a UE is in this interval.
9-132
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSDPA_Average_User_Rate_Distribution_2048_2304Kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the the average rate in MAC-HS layer is 2048-2304 Kbits/s.
Description
This counter indicates the number of UE whose rate keeps 2048-2304 Kbits/s. in a
sampling period. This counter increases once the rate of the UE keeps 2048-2304 Kbits/s.
Updates
This counter counts the subscribers with the average rate of 2048-2304 Kbits/s in the
statistical process of DPA subscriber rate distribution. This counter is updated when the
average rate of a UE is in this interval.
9-133
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSDPA_Average_User_Rate_Distribution_2304_2560Kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the the average rate in MAC-HS layer is 2304-2560 Kbits/s.
Description
This counter indicates the number of UE whose rate keeps 2304-2560 Kbits/s. in a
sampling period. This counter increases once the rate of the UE keeps 2304-2560 Kbits/s.
Updates
This counter counts the subscribers with the average rate of 2304-2560 Kbits/s in the
statistical process of DPA subscriber rate distribution. This counter is updated when the
average rate of a UE is in this interval.
9-134
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSDPA_Average_User_Rate_Distribution_2560_2816Kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the the average rate in MAC-HS layer is 2560-2816 Kbits/s.
Description
This counter indicates the number of UE whose rate keeps 2560-2816 Kbits/s. in a
sampling period. This counter increases once the rate of the UE keeps 2560-2816 Kbits/s.
Updates
This counter counts the subscribers with the average rate of 2560-2816 Kbits/s in the
statistical process of DPA subscriber rate distribution. This counter is updated when the
average rate of a UE is in this interval.
9-135
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSDPA_Average_User_Rate_Distribution_2816_3072Kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the the average rate in MAC-HS layer is 2816-3072 Kbits/s.
Description
This counter indicates the number of UE whose rate keeps 2816-3072 Kbits/s. in a
sampling period. This counter increases once the rate of the UE keeps 2816-3072 Kbits/s.
Updates
This counter counts the subscribers with the average rate of 2816-3072 Kbits/s in the
statistical process of DPA subscriber rate distribution. This counter is updated when the
average rate of a UE is in this interval.
9-136
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSDPA_Average_User_Rate_Distribution_3072_3328Kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the the average rate in MAC-HS layer is 3072-3328 Kbits/s.
Description
This counter indicates the number of UE whose rate keeps 3072-3328 Kbits/s. in a
sampling period. This counter increases once the rate of the UE keeps 3072-3328 Kbits/s.
Updates
This counter counts the subscribers with the average rate of 3072-3328 Kbits/s in the
statistical process of DPA subscriber rate distribution. This counter is updated when the
average rate of a UE is in this interval.
9-137
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSDPA_Average_User_Rate_Distribution_3328_3584Kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the the average rate in MAC-HS layer is 3328-3584 Kbits/s.
Description
This counter indicates the number of UE whose rate keeps 3328-3584 Kbits/s. in a
sampling period. This counter increases once the rate of the UE keeps 3328-3584 Kbits/s.
Updates
This counter counts the subscribers with the average rate of 3328-3584 Kbits/s in the
statistical process of DPA subscriber rate distribution. This counter is updated when the
average rate of a UE is in this interval.
9-138
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSDPA_Average_User_Rate_Distribution_3584_4096Kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the the average rate in MAC-HS layer is 3584-4096 Kbits/s.
Description
This counter indicates the number of UE whose rate keeps 3584-4096 Kbits/s. in a
sampling period. This counter increases once the rate of the UE keeps 3584-4096 Kbits/s.
Updates
This counter counts the subscribers with the average rate of 3584-4096 Kbits/s in the
statistical process of DPA subscriber rate distribution. This counter is updated when the
average rate of a UE is in this interval.
9-139
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSDPA_Average_User_Rate_Distribution_4096_5120Kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the the average rate in MAC-HS layer is 4096-5120 Kbits/s.
Description
This counter indicates the number of UE whose rate keeps 4096-5120 Kbits/s. in a
sampling period. This counter increases once the rate of the UE keeps 4096-5120 Kbits/s.
Updates
This counter counts the subscribers with the average rate of 4096-5120 Kbits/s in the
statistical process of DPA subscriber rate distribution. This counter is updated when the
average rate of a UE is in this interval.
9-140
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSDPA_Average_User_Rate_Distribution_5120_6144Kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the the average rate in MAC-HS layer is 5120-6144 Kbits/s.
Description
This counter indicates the number of UE whose rate keeps 5120-6144 Kbits/s. in a
sampling period. This counter increases once the rate of the UE keeps 5120-6144 Kbits/s.
Updates
This counter counts the subscribers with the average rate of 5120-6144 Kbits/s in the
statistical process of DPA subscriber rate distribution. This counter is updated when the
average rate of a UE is in this interval.
9-141
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSDPA_Average_User_Rate_Distribution_6144_7168Kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the the average rate in MAC-HS layer is 6144-7168 Kbits/s.
Description
This counter indicates the number of UE whose rate keeps 6144-7168 Kbits/s. in a
sampling period. This counter increases once the rate of the UE keeps 6144-7168 Kbits/s.
Updates
This counter counts the subscribers with the average rate of 6144-7168 Kbits/s in the
statistical process of DPA subscriber rate distribution. This counter is updated when the
average rate of a UE is in this interval.
9-142
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSDPA_Average_User_Rate_Distribution_6144_7168_Kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the the average rate in MAC-HS layer is above 7168 Kbits/s.
Description
This counter indicates the number of UE whose rate keeps above 7168Kbits/s. in a
sampling period. This counter increases once the rate of the UE keeps above 7168Kbits/s.
Updates
This counter counts the subscribers with the average rate of above 7168 Kbits/s in the
statistical process of DPA subscriber rate distribution. This counter is updated when the
average rate of a UE is in this interval.
9-143
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_Received_ACK_for_a_given_TBS_HSDPA_64_QAM
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When scheduling in 64QAM modulation mode and receiving ACK messages.
Description
This counter indicates the number of ACK messages received after the TB module is sent
in the 64QAM modulation mode in a sampling period.
Updates
The counter increases by 1 when ACK message is received after the TB module is sent in
the 64QAM modulation mode in a sampling period.
9-144
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_Received_NACK_for_a_given_TBS_HSDPA_64_QAM
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When scheduling in 64QAM modulation mode and receiving NACK messages.
Description
This counter indicates the number of NACK messages received after the TB module is
sent in the 64QAM modulation mode in a sampling period.
Updates
The counter increases by 1 when NACK message is received after the TB module is sent
in the 64QAM modulation mode in a sampling period.
9-145
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_Received_ACK_for_a_given_TBS_HSDPA_16_QAM
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When scheduling in 16QAM modulation mode and receiving ACK messages.
Description
This counter indicates the number of ACK messages received after the TB module is sent
in the 16QAM modulation mode in a sampling period.
Updates
The counter increases by 1 when ACK message is received after the TB module is sent in
the 16QAM modulation mode in a sampling period.
9-146
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_Received_NACK_for_a_given_TBS_HSDPA_16_QAM
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When scheduling in 16QAM modulation mode and receiving NACK messages.
Description
This counter indicates the number of NACK messages received after the TB module is
sent in the 16QAM modulation mode in a sampling period.
Updates
The counter increases by 1 when NACK message is received after the TB module is sent
in the 16QAM modulation mode in a sampling period.
9-147
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_Received_ACK_for_a_given_TBS_HSDPA_QPSK
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When scheduling in QPSK modulation mode and receiving ACK messages.
Description
This counter indicates the number of ACK messages received after the TB module is sent
in the QPSK modulation mode in a sampling period.
Updates
The counter increases by 1 when ACK message is received after the TB module is sent in
the QPSK modulation mode in a sampling period.
9-148
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_Received_NACK_for_a_given_TBS_HSDPA_QPSK
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When scheduling in QPSK modulation mode and receiving NACK messages.
Description
This counter indicates the number of NACK messages received after the TB module is
sent in the QPSK modulation mode in a sampling period.
Updates
The counter increases by 1 when NACK message is received after the TB module is sent
in the QPSK modulation mode in a sampling period.
9-149
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_Received_NACK_HSDPA
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the UE decoding on HS-DSCH fails.
Description
This counter indicates the number of NACK messages received in a sampling period.
Updates
The counter increases by 1 when one NACK message is received in a sampling period.
9-150
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_Received_ACK_HSDPA
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the UE decoding on HS-SCCH and HS-DSCH fails.
Description
This counter indicates the number of ACK messages received in a sampling period.
Updates
The counter increases by 1 when one ACK message is received in a sampling period.
Short Form
Number_of_Received_DTX_HSDPA
Sampling Period
15 minutes
Counter Type
Accumulation
9-151
SJ-20100510160815-008|2011-01-04(R5.0)
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the UE decoding on HS-SCCH fails.
Description
This counter indicates the number of DTX messages received in a sampling period.
Updates
The counter increases by 1 when one DTX message is received in a sampling period.
Short Form
NACK_Rate_HSDPA
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the UE decoding on HS-SCCH and HS-DSCH fails.
9-152
SJ-20100510160815-008|2011-01-04(R5.0)
Description
This counter indicates the proportion of the sum of received NACK messages and
received DTX messages and the number of responses (the sum of ACK messages,
NACK message, and DTX messages) in the sampling period.
Updates
In the sampling period, when one NACK or DTX message is received, the Node B records
the number of NACK responses and the number of DTX responses and sums up the two
numbers. Then the counter calculates the rate of the total number of NACK and DTX
responses to the total number of responses (ACKNACKDTX).
Short Form
Number_of_ResBler_HSDPA
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When the consecutive retransmission is over three times.
Description
This counter indicates the number of consecutive retransmission is over three times in a
sampling period.
9-153
SJ-20100510160815-008|2011-01-04(R5.0)
Updates
The counter increases by 1 when the consecutive retransmission is over three times in a
sampling period.
Short Form
Data_of_Successful_MAChs_PDUs
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When DPA scheduler receives ACK message from a UE.
Description
This counter indicates the number of bits of successfully-transmitted MAC-HS PDU
(respond to ACK message) in a sampling period.
Updates
This counter is updated by the number of bits of the successfully-transmitted MAC-HS PDU
when MAC-HS PDU is successfully transmitted to repond to ACK message in a sampling
period.
9-154
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_HSDPA_Scheduling_UE
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When a UE is in the scheduling.
Description
This counter indicates the number of UE with schedule in TTI in a sampling period.
Updates
This counter is updated when a UE with scheduling in TTI is found in a sampling period.
Short Form
Number_of_Successful_MAChs_PDUs
9-155
SJ-20100510160815-008|2011-01-04(R5.0)
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
When DPA scheduler receives ACK message from a UE.
Description
This counter indicates the number of packages of successfully-transmitted MAC-HS PDU
(respond to ACK message) in a sampling period.
Updates
The counter increases by 1 when the MAC-HS PDU successfully transmitted data and
responded ACK message in a sampling period.
Short Form
Number_of_MAChs_PDUs_with_Retransmission
Sampling Period
15 minutes
Counter Type
Accumulation
9-156
SJ-20100510160815-008|2011-01-04(R5.0)
Unit
times
Measurement Object
DPA Cell
Sampling Point
When a MAC-HS-PDU retransmits.
Description
This counter indicates the number of packages of the re-transmitted MAC-HS PDU in a
sampling period.
Updates
The counter increases by 1 when the MAC-HS PDU is re-transmitted in the sampling
period.
Short Form
HSDPA_MAChs_Efficiency
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
DPA Cell
9-157
SJ-20100510160815-008|2011-01-04(R5.0)
Sampling Point
This counter is updated when there is data scheduling on the DPA scheduler.
Description
This counter indicates the percentage of successfully-transmitted MAC-HS PDU packages
(by sending the ACK message) to transmitted MAC-HS PDU packages (including those
re-transmitted) in the sampling period.
Updates
This counter counts the percentage of successfully-transmitted MAC-HS PDU packages
(by sending the ACK message) to transmitted MAC-HS PDU packages (including those
re-transmitted) in the sampling period.
Short Form
Discarded_MACD_PDU_rate
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
DPA Cell
Sampling Point
This counter is updated when the MAC-D PDU is discarded.
9-158
SJ-20100510160815-008|2011-01-04(R5.0)
Description
This counter indicates the percentage of discarded MAC-D PDUs (including those
discarded due to RNC FLUSH, due to timeout, and due to not receiving ACK response
even after reaching the maximum retransmission times) to received MAC-D PUDs in the
sampling period.
Updates
This counter counts when there is discarded MAC-D PDUs (including those discarded due
to RNC FLUSH, due to timeout, and due to not receiving ACK response even after reaching
the maximum retransmission times). At the same time, it counts the number of received
MAC-D PUDs currently. Then, this counter gets the percentage.
Short Form
HSDPA_Scheduling_Rate
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
DPA Cell
Sampling Point
The percentage of TTI with scheduling to TTI with data to be scheduled.
Description
This counter indicates the percentage of TTI with scheduling to TTI with data to be
scheduled (Formula to calculate the percentage of TTI with scheduling to TTI with
9-159
SJ-20100510160815-008|2011-01-04(R5.0)
scheduling data but not scheduled: Number of TTI with scheduling data/(Number of TTI
with scheduling data but not scheduled + Number of TTI with scheduling data)) in the
sampling period.
Updates
This counter counts the number of TTI with scheduling in the sampling period. At the
same times, it counts the number of TTI with scheduling data but not scheduled. Then,
this counter gets the percentage with the formula of Number of TTI with scheduling
data/(Number of TTI with scheduling data but not scheduled + Number of TTI with
scheduling data).
Short Form
HSDPA_RAB_Activity_Factor
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
DPA Cell
Sampling Point
This counter is updated when there is data scheduling in the cell.
Description
This counter indicates the percentage of TTI with scheduling to the sampling period in the
sampling period (15 minutes).
9-160
SJ-20100510160815-008|2011-01-04(R5.0)
Updates
This counter counts the number of TTI with scheduling in the sampling period. The number
of TTI without scheduling is not counted. Then, the count gets the sampling with the
formula: The number of TTI with scheduling/Sampling period.
Short Form
Data_lost_due_to_HSDSCH_congestion
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
This counter is updated when there is a congestion on the Iub interface.
Description
This counter indicates the number of bits discarded due to the congestion on the HS-DSCH
Iub interface in the sampling period. That is, if MAC-HS FSN is found leaping when the
downlink data frame is received, the size of the lost MAC-HS PDU is added.
Updates
This counter counts the number of bits discarded due to the congestion on the HS-DSCH
Iub interface in the sampling period. That is, if MAC-HS FSN is found leaping when the
9-161
SJ-20100510160815-008|2011-01-04(R5.0)
downlink data frame is received, this counter increases by the size of the lost MAC-HS
PDU.
Short Form
Number_of_Capacity_Alloc_Frame_due_to_too_much_data
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
This counter is updated when the data stored in the DPA scheduler is too much.
Description
In the sampling period, when the data throughput to be transmitted accumulates at the
Node B and crosses the threshold, this counter increases by 1.
Updates
In the sampling period, when the data throughput to be transmitted accumulates at the
Node B and crosses the threshold, this counter increases by 1.
9-162
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_Capacity_Alloc_Frame_due_to_too_few_data
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
DPA Cell
Sampling Point
This counter is updated when the data stored in the DPA scheduler is too little.
Description
In the sampling period, when the data throughput to be transmitted accumulated at the
Node B is too little and it is below the threshold, this counter increases by 1.
Updates
In the sampling period, when the data throughput to be transmitted accumulated at the
Node B is too little and it is below the threshold, this counter increases by 1.
9-163
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSDPA_Scheduling_Delay
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
DPA Cell
Sampling Point
The time delay from when the HSDPA receives the data to when the scheduler sends the
data.
Description
This counter indicates the time delay from when the HSDPA receives the data to when the
scheduler sends the data, that is, the procedure from with data to without data. The cell
takes the average value within the statistical period.
Updates
This counter counts the time delay from when the HSDPA receives the data to when the
scheduler sends the data, that is, the procedure from with data to without data. The cell
takes the average value within the statistical period. The formula: Average scheduling
time delay of the UE = Sum of scheduling time delay/Number of scheduling times.
9-164
SJ-20100510160815-008|2011-01-04(R5.0)
Chapter 10
10-2
SJ-20100510160815-008|2011-01-04(R5.0)
10-3
SJ-20100510160815-008|2011-01-04(R5.0)
10-4
SJ-20100510160815-008|2011-01-04(R5.0)
Figure 10-3 The Flow Chart of UE Scheduling Information and Decoding State Updating
l
l
l
l
10-5
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
AG_Ratio_for_2ms_TTI_UE
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the HSUPA 2ms TTI user applies for AG successfully.
Description
This counter indicates the percentage of the number of times that HSUPA 2ms TTI user
sends AG to the number of times that the AG is sent in the sampling period.
Updates
This counter counts the percentage of the number of times that HSUPA 2ms TTI user
sends AG to the number of times that the AG is sent in the sampling period.
Short Form
Usage_Ratio_of_AGCH
10-6
SJ-20100510160815-008|2011-01-04(R5.0)
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the HSUPA user applies for AG successfully.
Description
This counter indicates the percentage of the number of times that all HSUPA users send
AG to the number of available times of AG in the sampling period.
Updates
This counter counts the percentage of the number of times that all HSUPA users send AG
to the number of available times of AG in the sampling period.
Short Form
Average_Number_of_Retransmsstion_when_ACK
Sampling Period
15 minutes
Counter Type
Average Value
10-7
SJ-20100510160815-008|2011-01-04(R5.0)
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the E-DCH decoding succeeds and the RSN message is
received (indicating the retransmission).
Description
This counter indicates the average number of retransmission times on the E-DCH in the
current HSUPA cell in the sampling period.
Updates
This counter counts the average number of retransmission times on the E-DCH in the
current HSUPA cell in the sampling period.
Short Form
Average_User_Number_HSUPA
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
UPA Cell
10-8
SJ-20100510160815-008|2011-01-04(R5.0)
Sampling Point
This counter is updated when the HSUPA user is detected to be in the active state.
Description
This counter indicates the average number of HSUPA users in activated state in the
sampling period.
Updates
This counter counts the percentage of activated HSUPA users that the HSUPA scheduler
queries to the number of query times in the sampling period.
Short Form
Max_User_Number_HSUPA
Sampling Period
15 minutes
Counter Type
Maximum value
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the HSUPA user is detected to be in the active state.
Description
This counter indicates the maximum number of HSUPA users in activated state in the
sampling period.
10-9
SJ-20100510160815-008|2011-01-04(R5.0)
Updates
This counter counts the number of on-line users every 100m in the sampling period and
saves the maximum value.
Short Form
Number_of_MACe_PDUs
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the E-TFCI obtained by demodulating E-DPCCH is valid.
Description
This counter indicates the number of MAC-e PDUs received on the MAC-e layer of the
Node B in the sampling period.
Updates
In the sampling period, if the UE is on line and the E-TFCI obtained by demodulating
E-DPCCH is valid, the UE is considered to be with MAC-e data and this counter increases
by 1.
10-10
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_ACK_MACe_PDUs
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the MAC-e PDU decoding succeeds.
Description
This counter indicates the number of MAC-e PDUs that are received on the MAC-e layer
of the Node B and are correctly decoded in the sampling period.
Updates
In the sampling period, if the UE is on line and the E-TFCI obtained by demodulating
E-DPCCH is valid and correct, the UE is considered to be with MAC-e data and this counter
increases by 1.
10-11
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_Received_Data_bits
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the E-TFCI obtained by demodulating E-DPCCH is valid.
Description
This counter indicates the number of MAC-e PDU bits received on the MAC-e layer of the
Node B in the sampling period.
Updates
This counter counts the number of all activated EDCH MAC-e PDU bits in the cell in the
sampling period. That is, this counter increases by the TB size of each TTI.
Short Form
Total_Number_of_Data_bits_Send_to_RNC
Sampling Period
15 minutes
10-12
SJ-20100510160815-008|2011-01-04(R5.0)
Counter Type
Accumulation
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the MAC-e PDU decoding succeeds.
Description
This counter indicates the number of MAC-e PDU bits that are received on the MAC-e
layer of the Node B and are correctly decoded in the sampling period.
Updates
This counter counts the number of EDCH MAC-e PDU bits that are received in the cell and
are correctly decoded in the sampling period.
Short Form
HSUPA_Traffic_16_QAM
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
10-13
SJ-20100510160815-008|2011-01-04(R5.0)
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the E-TFCI obtained by demodulating E-DPCCH is valid.
Description
This counter indicates the number of MAC-e PDU bits that are received through the 16QAM
modulation on the MAC-e layer of the Node B in the sampling period.
Updates
During the sampling period, the HSUPA scheduler adds the number of EDCH MAC-e PDU
bits that are received through the 16 QAM modulation in the cell.
Short Form
HSUPA_16_QAM_usage_ratio
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the E-TFCI obtained by demodulating E-DPCCH is valid.
10-14
SJ-20100510160815-008|2011-01-04(R5.0)
Description
This counter indicates the percentage of MAC-e PDU bits that are received through the
16QAM modulation on the MAC-e layer of the Node B to the MAC-e PDU bits in the
sampling period.
Updates
During the sampling period, the HSUPA scheduler counts the percentage of MAC-e PDU
bits that are sent through the 16QAM modulation to the MAC-e PDU bits that are sent.
Short Form
HSUPA_Duration_Activity
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the E-TFCI obtained by demodulating E-DPCCH is valid.
Description
This counter indicates the total duration that the HSUPA users continuously sends E-DCH
data in the sampling period.
Updates
During the sampling period, the HSUPA scheduler adds the duration that the E-DCH data
is received in the cell, in the unit of 2ms.
10-15
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSUPA_Average_Throughput_per_User
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the MAC-e PDU decoding succeeds.
Description
This counter indicates the average throughput of the HUSPA users in the cell in the
sampling period. The formula: The number of MAC-e PDU bits received and successfully
decoded/the duration when the HSUPA user is on line.
Updates
During the sampling period, this counter counts with the formula: The number of MAC-e
PDU bits received and successfully decoded/the duration when the HSUPA user is on line.
Short Form
HSUPA_Average_User_Rate_Distribution_0_8kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the MAC-e PDU decoding succeeds.
Description
This counter indicates the number of HSUPA users whose average percentage is within
0-8 kbps in the cell in the sampling period.
Updates
During the sampling period, the formula to calculate the average rate of each user is:
Number of received bits/Sum of scheduling time. If the average rate is within 0-8 kbps,
this counter increases by 1.
Short Form
HSUPA_Average_User_Rate_Distribution_8_32kbps
Sampling Period
15 minutes
10-17
SJ-20100510160815-008|2011-01-04(R5.0)
Counter Type
Accumulation
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the MAC-e PDU decoding succeeds.
Description
This counter indicates the number of HSUPA users whose average percentage is within
8-32 kbps in the cell in the sampling period.
Updates
During the sampling period, the formula to calculate the average rate of each user is:
Number of received bits/Sum of scheduling time. If the average rate is within 8-32 kbps,
this counter increases by 2.
Short Form
HSUPA_Average_User_Rate_Distribution_32_64kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
10-18
SJ-20100510160815-008|2011-01-04(R5.0)
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the MAC-e PDU decoding succeeds.
Description
This counter indicates the number of HSUPA users whose average percentage is within
32-64 kbps in the cell in the sampling period.
Updates
During the sampling period, the formula to calculate the average rate of each user is:
Number of received bits/Sum of scheduling time. If the average rate is within 32-64 kbps,
this counter increases by 3.
Short Form
HSUPA_Average_User_Rate_Distribution_64_128kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the MAC-e PDU decoding succeeds.
10-19
SJ-20100510160815-008|2011-01-04(R5.0)
Description
This counter indicates the number of HSUPA users whose average percentage is within
64-128 kbps in the cell in the sampling period.
Updates
During the sampling period, the formula to calculate the average rate of each user is:
Number of received bits/Sum of scheduling time. If the average rate is within 64-128 kbps,
this counter increases by 4.
Short Form
HSUPA_Average_User_Rate_Distribution_128_256kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the MAC-e PDU decoding succeeds.
Description
This counter indicates the number of HSUPA users whose average percentage is within
128-256 kbps in the cell in the sampling period.
10-20
SJ-20100510160815-008|2011-01-04(R5.0)
Updates
During the sampling period, the formula to calculate the average rate of each user is:
Number of received bits/Sum of scheduling time. If the average rate is within 128-256
kbps, this counter increases by 5.
Short Form
HSUPA_Average_User_Rate_Distribution_256_384kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the MAC-e PDU decoding succeeds.
Description
This counter indicates the number of HSUPA users whose average percentage is within
256-384 kbps in the cell in the sampling period.
Updates
During the sampling period, the formula to calculate the average rate of each user is:
Number of received bits/Sum of scheduling time. If the average rate is within 256-384
kbps, this counter increases by 6.
10-21
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSUPA_Average_User_Rate_Distribution_384_512kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the MAC-e PDU decoding succeeds.
Description
This counter indicates the number of HSUPA users whose average percentage is within
384-512 kbps in the cell in the sampling period.
Updates
During the sampling period, the formula to calculate the average rate of each user is:
Number of received bits/Sum of scheduling time. If the average rate is within 384-512
kbps, this counter increases by 7.
10-22
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSUPA_Average_User_Rate_Distribution_512_768kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the MAC-e PDU decoding succeeds.
Description
This counter indicates the number of HSUPA users whose average percentage is within
512-768 kbps in the cell in the sampling period.
Updates
During the sampling period, the formula to calculate the average rate of each user is:
Number of received bits/Sum of scheduling time. If the average rate is within 512-768
kbps, this counter increases by 8.
10-23
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSUPA_Average_User_Rate_Distribution_768_1024kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the MAC-e PDU decoding succeeds.
Description
This counter indicates the number of HSUPA users whose average percentage is within
768-1024 kbps in the cell in the sampling period.
Updates
During the sampling period, the formula to calculate the average rate of each user is:
Number of received bits/Sum of scheduling time. If the average rate is within 768-1024
kbps, this counter increases by 9.
10-24
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSUPA_Average_User_Rate_Distribution_1024_1280kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the MAC-e PDU decoding succeeds.
Description
This counter indicates the number of HSUPA users whose average percentage is within
1024-1280 kbps in the cell in the sampling period.
Updates
During the sampling period, the formula to calculate the average rate of each user is:
Number of received bits/Sum of scheduling time. If the average rate is within 1024-1280
kbps, this counter increases by 10.
10-25
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSUPA_Average_User_Rate_Distribution_1280_1536kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the MAC-e PDU decoding succeeds.
Description
This counter indicates the number of HSUPA users whose average percentage is within
1280-1536 kbps in the cell in the sampling period.
Updates
During the sampling period, the formula to calculate the average rate of each user is:
Number of received bits/Sum of scheduling time. If the average rate is within 1280-15368
kbps, this counter increases by 11.
10-26
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSUPA_Average_User_Rate_Distribution_1536_1792kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the MAC-e PDU decoding succeeds.
Description
This counter indicates the number of HSUPA users whose average percentage is within
1536-1792 kbps in the cell in the sampling period.
Updates
During the sampling period, the formula to calculate the average rate of each user is:
Number of received bits/Sum of scheduling time. If the average rate is within 1536-1792
kbps, this counter increases by 12.
10-27
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSUPA_Average_User_Rate_Distribution_1792_2048kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the MAC-e PDU decoding succeeds.
Description
This counter indicates the number of HSUPA users whose average percentage is within
1792-2048 kbps in the cell in the sampling period.
Updates
During the sampling period, the formula to calculate the average rate of each user is:
Number of received bits/Sum of scheduling time. If the average rate is within 1792-2048
kbps, this counter increases by 13.
10-28
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSUPA_Average_User_Rate_Distribution_2048_2304kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the MAC-e PDU decoding succeeds.
Description
This counter indicates the number of HSUPA users whose average percentage is within
2048-2304 kbps in the cell in the sampling period.
Updates
During the sampling period, the formula to calculate the average rate of each user is:
Number of received bits/Sum of scheduling time. If the average rate is within 2048-2304
kbps, this counter increases by 14.
10-29
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSUPA_Average_User_Rate_Distribution_2304_2560kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the MAC-e PDU decoding succeeds.
Description
This counter indicates the number of HSUPA users whose average percentage is within
2304-2560 kbps in the cell in the sampling period.
Updates
During the sampling period, the formula to calculate the average rate of each user is:
Number of received bits/Sum of scheduling time. If the average rate is within 2304-2560
kbps, this counter increases by 15.
10-30
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSUPA_Average_User_Rate_Distribution_2560_2816kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the MAC-e PDU decoding succeeds.
Description
This counter indicates the number of HSUPA users whose average percentage is within
2560-2816 kbps in the cell in the sampling period.
Updates
During the sampling period, the formula to calculate the average rate of each user is:
Number of received bits/Sum of scheduling time. If the average rate is within 2560-2816
kbps, this counter increases by 16.
10-31
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSUPA_Average_User_Rate_Distribution_2816_3072kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the MAC-e PDU decoding succeeds.
Description
This counter indicates the number of HSUPA users whose average percentage is within
2816-3072 kbps in the cell in the sampling period.
Updates
During the sampling period, the formula to calculate the average rate of each user is:
Number of received bits/Sum of scheduling time. If the average rate is within 2816-3072
kbps, this counter increases by 17.
10-32
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSUPA_Average_User_Rate_Distribution_3072_3328kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the MAC-e PDU decoding succeeds.
Description
This counter indicates the number of HSUPA users whose average percentage is within
3072-3328 kbps in the cell in the sampling period.
Updates
During the sampling period, the formula to calculate the average rate of each user is:
Number of received bits/Sum of scheduling time. If the average rate is within 3072-3328
kbps, this counter increases by 18.
10-33
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSUPA_Average_User_Rate_Distribution_3328_3584kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the MAC-e PDU decoding succeeds.
Description
This counter indicates the number of HSUPA users whose average percentage is within
3328-3584 kbps in the cell in the sampling period.
Updates
During the sampling period, the formula to calculate the average rate of each user is:
Number of received bits/Sum of scheduling time. If the average rate is within 3328-3584
kbps, this counter increases by 19.
10-34
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSUPA_Average_User_Rate_Distribution_3584_4096kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the MAC-e PDU decoding succeeds.
Description
This counter indicates the number of HSUPA users whose average percentage is within
3584-4096 kbps in the cell in the sampling period.
Updates
During the sampling period, the formula to calculate the average rate of each user is:
Number of received bits/Sum of scheduling time. If the average rate is within 3584-4096
kbps, this counter increases by 20.
10-35
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSUPA_Average_User_Rate_Distribution_4096_5120kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the MAC-e PDU decoding succeeds.
Description
This counter indicates the number of HSUPA users whose average percentage is within
4096-5120 kbps in the cell in the sampling period.
Updates
During the sampling period, the formula to calculate the average rate of each user is:
Number of received bits/Sum of scheduling time. If the average rate is within 4096-5120
kbps, this counter increases by 21.
10-36
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSUPA_Average_User_Rate_Distribution_5120_6144kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the MAC-e PDU decoding succeeds.
Description
This counter indicates the number of HSUPA users whose average percentage is within
5120-6144 kbps in the cell in the sampling period.
Updates
During the sampling period, the formula to calculate the average rate of each user is:
Number of received bits/Sum of scheduling time. If the average rate is within 5120-6144
kbps, this counter increases by 22.
10-37
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSUPA_Average_User_Rate_Distribution_6144_7168kbps
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the MAC-e PDU decoding succeeds.
Description
This counter indicates the number of HSUPA users whose average percentage is within
6144-7168 kbps in the cell in the sampling period.
Updates
During the sampling period, the formula to calculate the average rate of each user is:
Number of received bits/Sum of scheduling time. If the average rate is within 6144-7168
kbps, this counter increases by 23.
10-38
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSUPA_Average_User_Rate_Distribution_7168kbps_inf
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the MAC-e PDU decoding succeeds.
Description
This counter indicates the number of HSUPA users whose average percentage is over
7168 kbps in the cell in the sampling period.
Updates
During the sampling period, the formula to calculate the average rate of each user is:
Number of received bits/Sum of scheduling time. If the average rate is over 7168, this
counter increases by 24.
Short Form
Number_of_Received_NACK_HSUPA
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the MAC-e PDU decoding succeeds.
Description
This counter indicates the number of times that the NACK message is sent when Node B
MAC-e PDU decoding fails in the sampling period.
Updates
During the sampling period, if the MAC-e PDU decoding fails, this counter increases by 1.
Short Form
Number_of_Received_ACK_HSUPA
Sampling Period
15 minutes
Counter Type
Accumulation
10-40
SJ-20100510160815-008|2011-01-04(R5.0)
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the MAC-e PDU decoding succeeds.
Description
This counter indicates the number of times that the ACK message is sent when Node B
MAC-e PDU decoding succeeds in the sampling period.
Updates
During the sampling period, if the MAC-e PDU decoding succeeds, this counter increases
by 1.
Short Form
Number_of_Received_DTX_HSUPA
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the E-TFCI is not decoded successfully.
10-41
SJ-20100510160815-008|2011-01-04(R5.0)
Description
This counter indicates the number of times that the DTX message is sent when the Node
B does not detect the E-TFCI in the sampling period.
Updates
During the sampling period, if MAC-e PDU is not detected, this counter increases by 1.
Short Form
NACK_rate_HSUPA
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the MAC-e PDU decoding fails.
Description
This counter indicates the percentage of Node B MAC-e PDU decoding failures in the
sampling period.
Updates
During the sampling period, this counter counts with the formula of (Number of NACK
messages)/(Number of NACK messages + Number of ACK messages + Number of DTX).
10-42
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Number_of_Successful_MACe_PDUs
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the MAC-e PDU decoding succeeds.
Description
This counter indicates the number of MAC-e PDUs that are received on the MAC-e layer
of the Node B and are correctly decoded in the sampling period.
Updates
During the sampling period, the HSUPA scheduler adds the number of EDCH MAC-e PDUs
whose decoding is correct in the cell.
Short Form
Number_of_MACe_PDUs_with_Retransmission
Sampling Period
15 minutes
Counter Type
Accumulation
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the MAC-e PDU decoding fails.
Description
This counter indicates the number of MAC-e PDUs that are received on the MAC-e layer
of the Node B and are unsuccessfully decoded in the sampling period.
Updates
During the sampling period, the HSUPA scheduler adds the number of EDCH MAC-e PDUs
whose decoding fails in the cell.
Short Form
HSUPA_MACe_Efficiency
Sampling Period
15 minutes
Counter Type
Average Value
10-44
SJ-20100510160815-008|2011-01-04(R5.0)
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the E-TFCI obtained by demodulating E-DPCCH is valid.
Description
This counter indicates the percentage of MAC-e PDU decoding successes in the sampling
period. The formula: The number of successfully-decoded MAC-e PDUs/The sum of all
received MAC-e PDUs.
Updates
During the sampling period, this counter counts with the formula of (Number of MAC-e
PDUs whose decoding succeeds)/(Number of MAC-e PDUs whose decoding succeeds +
Number of all retransmitted MAC-e PDUs).
Short Form
HSUPA_Scheduling_Rate
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
UPA Cell
10-45
SJ-20100510160815-008|2011-01-04(R5.0)
Sampling Point
This counter is updated when the HSUPA scheduling is being performed.
Description
This counter indicates the percentage of HSUPA scheduling in the sampling period. The
formula: Duration of HSUPA scheduling/Duration when there is data of UE transmitted.
Updates
During the sampling period, this counter counts with the formula of Sum of all scheduling
time/Duration when there is data to be transmitted.
Short Form
HSUPA_RAB_Activity_Factor
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the E-TFCI obtained by demodulating E-DPCCH is valid.
Description
This counter indicates the percentage of E-DCH data transmission time length. The
formula: Duration when there is data of UE transmitted/Duration when the UE is on line.
10-46
SJ-20100510160815-008|2011-01-04(R5.0)
Updates
During the sampling period, this counter counts with the formula of Duration that E-DSCH
data transmission is detected by the HSUPA scheduler/Sum of duration that the HSUPA
UA is on line.
Short Form
HSUPA_BLER
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the MAC-e PDU decoding fails.
Description
This counter indicates the percentage of MAC-e PDUs that are unsuccessfully decoded in
the sampling period.
Updates
During the sampling period, this counter counts with the formula of (Number of
retransmitted MAC-e PDUs)/(Number of MAC-e PDUs successfully sent + Number of
retransmitted MAC-PDUs).
10-47
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSUPA_Average_Scheduling_Delay
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when TEBS>0 and SG<(the number of SG required for one PDU).
Description
This counter indicates the average scheduling delay of HSUPA scheduler in the sampling
period.
Updates
During the sampling period, the HSUPA scheduler detects that TEBS is larger than 0 and
it counts the time difference from when there is no allocated authority (no PDU is sent) to
when there is authority (at least one PDU is sent).
10-48
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
HSUPA_Happy_Ratio
Sampling Period
15 minutes
Counter Type
Average Value
Unit
times
Measurement Object
UPA Cell
Sampling Point
This counter is updated when the E-DPCCH decoding succeeds and happy bit is obtained.
Description
This counter indicates the percentage of HSUPA UE happy in the sampling period.
Updates
During the sampling period, the HSUPA scheduler counts the number of UE happy times
and UE unhappy times. This counter counts with the formula of Number of UE happy
times/(Number of UE happy times + Number of UE unhappy times).
10-49
SJ-20100510160815-008|2011-01-04(R5.0)
10-50
SJ-20100510160815-008|2011-01-04(R5.0)
Chapter 11
11-1
SJ-20100510160815-008|2011-01-04(R5.0)
Short Form
Maximum_Power
11-2
SJ-20100510160815-008|2011-01-04(R5.0)
Sampling Period
15 minutes
Counter Type
Maximum value
Unit
dBm
Measurement Object
RRU
Sampling Point
The maximum power in a sampling period
Description
This counter calculates the maximum power of a RRU in a sampling period.
Updates
In a sampling period, once the value of accumulative maximum power changes, the
counter updates.
Short Form
Minimum_Power
Sampling Period
15 minutes
Counter Type
Minimum value
Unit
dBm
11-3
SJ-20100510160815-008|2011-01-04(R5.0)
Measurement Object
RRU
Sampling Point
The minimum power in a sampling period
Description
This counter calculates the minimum power of a RRU in a sampling period.
Updates
In a sampling period, once the value of accumulative minimum power changes, the counter
updates.
Short Form
Average_Power
Sampling Period
15 minutes
Counter Type
Average Value
Unit
dBm
Measurement Object
RRU
Sampling Point
The average power in a sampling period
Description
This counter calculates the average power of a RRU in a sampling period.
11-4
SJ-20100510160815-008|2011-01-04(R5.0)
Updates
In a sampling period, once the value of accumulative average power changes, the counter
updates.
Short Form
Maximum_Temperature
Sampling Period
15 minutes
Counter Type
Maximum value
Unit
C
Measurement Object
RRU
Sampling Point
The maximum temperature in a sampling period
Description
This counter calculates the maximum temperature of a RRU in a sampling period.
Updates
In a sampling period, once the value of accumulative maximum temperature changes, the
counter updates.
Short Form
Minimum_Temperature
Sampling Period
15 minutes
Counter Type
Minimum value
Unit
C
Measurement Object
RRU
Sampling Point
The minimum temperature in a sampling period
Description
This counter calculates the minimum temperature of a RRU in a sampling period.
Updates
In a sampling period, once the value of accumulative minimum temperature changes, the
counter updates.
Short Form
Average_Temperature
Sampling Period
15 minutes
Counter Type
Average Value
11-6
SJ-20100510160815-008|2011-01-04(R5.0)
Unit
C
Measurement Object
RRU
Sampling Point
The average temperature in a sampling period
Description
This counter calculates the average temperature of a RRU in a sampling period.
Updates
In a sampling period, once the value of accumulative average temperature changes, the
counter updates.
11-7
SJ-20100510160815-008|2011-01-04(R5.0)
11-8
SJ-20100510160815-008|2011-01-04(R5.0)
Glossary
CE
- Channel Element
DPA
- Downlink Packet Access
FE
- Fast Ethernet
HSDPA
- High Speed Downlink Packet Access
IMA
- Inverse Multiplexing over ATM
KPI
- Key Performance Indicator
OMS
- Operation and Maintenance Subsystem
PPP
- Point to Point Protocol
PVC
- Permanent Virtual Channel
RSSI
- Received Signal Strength Indicator
TSSI
- Transmitted Signal Strength Indicator
UPA
- Uplink Packet Access