Direct Operated 3 Port Solenoid Valve

Series VX31/32/33
For Air, Water, Oil, Steam

Solenoid valves for various fluids used in a wide variety of applications


Improved
corrosion
resistance
Special magnetic
material adopted

Enclosure:
Equivalent
to IP65
Low-noise
construction
Special construction enables
to reduce the metal noise.
(DC specification)

Reduced power
consumption
(DC specification)

VX31: 6 W 4.5 W
VX32: 8 W 7 W
VX33: 11.5 W 10.5 W
Flame resistance
UL94V-0 conformed
Flame resistant mold coil material

Improved
maintenance
performance
Maintenance is performed easily
due to the threaded assembly.

306

Direct Operated 3 Port Solenoid Valve

Series VX31/32/33
For Air, Water, Oil, Steam

VX2
VXK

Single Unit

VXD

Valve

Normally Closed (N.C.) /


Normally Open (N.O.) /
Common (COM.)

Normally closed (N.C.)


Normally open (N.O.)
Common (COM.)

VXZ
VXS

Model
VX31 VX32 VX33

1.5 mm

2.2 mm

3 mm

4 mm
1/8
1/4
1/4
Port size
1/4
3/8
3/8

VXE

Orifice dia.

Solenoid Coil
Coil: Class B, Class H

Rated Voltage
100 VAC, 200 VAC, 110 VAC,
220 VAC, 240 VAC, 230 VAC,
48 VAC, 24 VDC, 12 VDC

VXP
VXR
VXH
VXF2

Material
Body
Seal

VX3

Brass (C37), Stainless steel


NBR, FKM, EPDM, PTFE, FFKM

VXA

Electrical Entry
Grommet
Conduit
DIN terminal
Conduit terminal

Manifold

Base
Common SUP/EXH type

Solenoid Coil
Coil: Class B, Class H

Rated Voltage
100 VAC, 200 VAC, 110 VAC,
220 VAC, 240 VAC, 230 VAC,
48 VAC, 24 VDC, 12 VDC

Electrical Entry
Grommet
Conduit
DIN terminal
Conduit terminal

Normally Closed (N.C.) /


Normally Open (N.O.) /
Common (COM.)
Model
VX31 VX32 VX33

1.5 mm

2.2 mm

3 mm

4 mm
EXH port OUT port IN port

Normally closed (N.C.)


Normally open (N.O.)
Common (COM.)

Brass (C37)
Aluminum
NBR, FKM, EPDM

Orifice dia.

Valve

Body
Base
Seal

(Common SUP/EXH type)


Port size

Material

1/4

1/8, 1/4

1/4

307

Series VX31/32/33

Common Specifications
Standard Specifications

Valve
specifications

Coil
specifications

Direct operated poppet


3.0
Brass (C37), Stainless steel
NBR, FKM, EPDM, PTFE, FFKM
Dusttight, Low jetproof (equivalent to IP65)
Location without corrosive or explosive gases

Valve construction
Withstand pressure (MPa)
Body material
Seal material
Enclosure
Environment
AC (Class B coil,
Built-in full-wave rectifier type)
Rated
voltage
AC (Class H coil)
DC
Allowable voltage fluctuation
AC (Class B coil,
Allowable Built-in full-wave rectifier type)
leakage
AC (Class H coil)
voltage
DC
Coil insulation type

100 VAC, 200 VAC, 110 VAC, 220 VAC, 230 VAC, 240 VAC, 48 VAC
24 VDC, 12 VDC
10% of rated voltage
5% or less of rated voltage
20% or less of rated voltage
2% or less of rated voltage
Class B, Class H

Electrical entry, Grommet with surge voltage suppressor (GS) has a rating of IP40.

Solenoid Coil Specifications


DC Specification
Model

VX31
VX32
VX33

Power consumption (W) Temperature rise (C) Note)


4.5
45
7
45
10.5
60

Note) The values are for an ambient temperature of 20C and at the rated voltage.

AC Specification (Class B coil, Built-in full-wave rectifier type)


Model

VX31
VX32
VX33

Apparent power (VA) Temperature rise (C) Note)


55
7
60
9.5
65
12

There is no difference in the frequency and the inrush and energized apparent power, since a rectifying circuit is used in the AC (Class B).
Note) The values are for an ambient temperature of 20C and at the rated voltage.

AC Specification (Class H coil)


Model

VX31
VX32
VX33

Frequency (Hz)
50
60
50
60
50
60

Apparent power (VA)


Energized
Inrush
33
14
28
12
65
33
55
27
94
50
79
41

Temperature rise (C) Note)


65
60
100
95
120
115

Note) The values are for an ambient temperature of 20C and at the rated voltage.

Contents

308

For Air /Single Unit P.310

For Vacuum Pad /Single Unit P.322

For Air /Manifold P.312

For Vacuum Pad /Manifold P.324

For Water /Single Unit P.314

Construction P.326

For Oil /Single Unit P.316

Dimensions /Single Unit P.327

For Oil /Manifold P.318

Dimensions /Manifold P.328

For Steam /Single Unit P.320

Replacement Parts P.329

Direct Operated 3 Port Solenoid Valve

Series VX31/32/33

Applicable Fluid Check List


All Options (Single Unit)

0
2
4

VX3

VX2
VXK

Option symbol
Option
symbol

Fluid and application

Nil

Air
Medium vacuum, Non-leak,
Oil-free

G
M Note 1, 2)
Note
1, 2)
V
Nil

Water
Heated water

Oil Note 3)

Steam (Max.183C)
Copper-free, Fluorine-free

Refer to page 310 and after for specifications and models.

Note 5)

Others

G
E
P
A
H
D
N
S
Q
J
P
B
C
K Note 1, 2)

Seal material

Body material/
Main valve poppet Fixed sealant Shading coil material Note 6)
NBR
FKM
NBR
EPDM

NBR
FKM
NBR
EPDM

Guide pin
material

Coil insulation
type Note 4)

PPS

VXZ

PPS

VXS

PPS

Stainless steel

VXP

PPS

VXR

Stainless steel

Stainless steel

Stainless steel

PPS

Stainless steel/Ag

Stainless steel

Brass (C37)
Stainless steel
Stainless steel
Brass (C37)
Brass (C37)
Stainless steel
Brass (C37)/Cu
Stainless steel/Ag
Brass (C37)

FKM

FKM

Stainless steel
Brass (C37)/Cu
Stainless steel/Ag

FFKM

PTFE

EPDM

EPDM

EPDM

EPDM

FFKM

PTFE

Brass (C37)/Cu
Stainless steel/Ag

Brass (C37)
Stainless steel

VXD

Note

VXE

VXH
COM. only

VXF2

VX3

COM. only

VXA

PPS
Stainless steel

COM. only, Oil-free

If using for other fluids, please consult with SMC.

All Options (Manifold)

1
3
5

VX3
Fluid and application

Air
Medium vacuum, Non-leak,
Oil-free
Oil

Note 3)

Others

Refer to page 312 and after for specifications and models.

00

Option symbol
Option
symbol

Seal material
Body material/
Main valve poppet Fixed sealant Shading coil material Note 6)

Guide pin
material

Coil insulation
type Note 4)
B

Nil

NBR

NBR

Brass (C37)

PPS

V Note 1, 2)

FKM

FKM

Brass (C37)

PPS

Brass (C37)

PPS

Brass (C37)/Cu

Stainless steel

Brass (C37)

PPS

Brass (C37)/Cu

Stainless steel

A
D
B
E

FKM

FKM

EPDM

EPDM

Aluminum is only available with the material for a manifold base.


If using for other fluids, please consult with SMC.
Note 1) The leakage amount (106 Pam3/s) of V, M options are values when differential pressure is 0.1 MPa.
Note 2) V, M and K options are for oil-free treatment.
Note 3) The dynamic viscosity of the fluid must not exceed 50 mm2/s.
Note 4) Coil insulation type Class H: AC spec. only, Class B/AC spec.: built-in full-wave rectifier type only
Note 5) The nuts (non-welded parts) are nickel plated on the Brass (C37) material.
Note 6) There is no shading coil attached to DC spec. or Class B/AC spec.

309

Series VX31/32/33

For Air /Single Unit


(Non-leak, Medium vacuum)

Model / Valve Specifications


N.C.
Symbol

N.O.
Symbol

1 3

COM.
Symbol

1 3

1 3

Note) Symbols for N.C. and N.O. types


The symbols show that the N.C. type: port 3 and N.O. type: port 1 are in a blocked state (-1).
However, use each port pressure in the state shown below.
N.C. type: Pressure at port 1 Pressure at port 2 Pressure at port 3
N.O. type: Pressure at port 3 Pressure at port 2 Pressure at port 1

Port size

Orifice
diameter
(mm)

1/8
(6A)

1.5
2.2
3
1.5
2.2

1/4
(8A)
3
4
2.2
3/8
(10A)

3
4

Model
VX311-01
VX312-01
VX313-01
VX311-02
VX312-02
VX322-02
VX332-02
VX313-02
VX323-02
VX333-02
VX324-02
VX334-02
VX322-03
VX332-03
VX323-03
VX333-03
VX324-03
VX334-03

Max. operating pressure differential


(MPa)
COM.
N.O.
N.C.
0.7
1
1
0.4
0.5
0.7
0.2
0.3
0.3
0.7
1
1
0.4
0.5
0.7
0.7
1
1.2
1
1.6
1.6
0.2
0.3
0.3
0.3
0.5
0.6
0.6
0.9
1
0.2
0.25
0.3
0.3
0.4
0.5
0.7
1
1.2
1
1.6
1.6
0.3
0.5
0.6
0.6
0.9
1
0.2
0.25
0.3
0.3
0.4
0.5

Flow characteristics
3

C[dm /(sbar)]
0.29
0.60
0.82
0.29
0.60

b
0.32
0.25
0.20
0.32
0.25

Cv
0.08
0.15
0.20
0.08
0.15

0.64

0.40

0.17

0.82

0.20

0.20

1.1

0.25

0.27

1.6

0.20

0.38

0.64

0.40

0.17

1.1

0.25

0.27

1.6

0.20

0.38

Max. system
pressure
(MPa)

Note)

Weight
(g)

380

2.0

530
730
380
530
730
530
730
530
730
530
730
530
730

Note) Weight of grommet type. Add 10 g for conduit, 30 g for DIN terminal, and 60 g for conduit terminal type respectively.
Also, add 60 g for VX31, 80 g for VX32 and VX33 respectively for bracket option.
Refer to Glossary of Terms on page 331, for details on the max. operating pressure differential and the max. system pressure.

Fluid and Ambient Temperature

Valve Leakage Rate


Internal Leakage / External Leakage

Power source
AC
DC

Fluid temperature (C)


Solenoid valve option (symbol)
V, M
Nil, G
10 Note) to 40
10 Note) to 60
10 Note) to 60
10 Note) to 40

Note) Dew point temperature: 10C or less

310

Ambient
temperature
(C)
20 to 60
20 to 40

Seal material
NBR, FKM

Leakage rate
Non-leak, Medium
vacuum Note)
From 0 to less than 1 MPa 1 cm3/min or less 106 Pam3/sec
3
or less
1 MPa or more
2 cm /min or less
Max. operating
pressure differential

Air

Note) The leakage amount (106 Pam3/sec) for the V and M option
are values when the differential pressure is 0.1 MPa.

Direct Operated 3 Port Solenoid Valve

Series VX31/32/33
For Air / Single Unit

How to Order (Single Unit)

VX 31 1 4
VX 31 1 4

DC
AC/Class B coil (Built-in
full-wave rectifier type)
Model

5 G 1
1 G R1

VX2
VXK

Orifice diameter

Refer to Table (1) shown


below for availability.

Bracket

Refer to Table (1) shown


below for availability.

Valve / Body type


0
2
4

01
01

Nil

None
With bracket

N.C. / Single unit


N.O. / Single unit
COM. / Single unit

Bracket is neither
mountable nor removable.

Solenoid valve option


Refer to Table (2) shown
below for availability.

Built-in full-wave
rectifier type

Port size
Suffix

Oil-free spec.

Rc
NPTF
G
NPT

T
F
N

VXR
VXH

Electrical entry
G - Grommet
GS- With grommet surge

C - Conduit

T - With conduit terminal


TS - With conduit terminal and

Connector
D - DIN terminal
DS - DIN terminal with surge

Refer to Table (3) shown below for availability.

TL - With conduit terminal

Refer to page 329 for ordering coil only.

TZ - With conduit

DL - DIN terminal with light


DZ - DIN terminal with

Rated voltage
1
2
3
4
5

100 VAC 50/60 Hz


200 VAC 50/60 Hz
110 VAC 50/60 Hz
220 VAC 50/60 Hz
24 VDC

6
7
8
J

VXF2

voltage suppressor

12 VDC
240 VAC 50/60 Hz
48 VAC 50/60 Hz
230 VAC 50/60 Hz

VX3
surge voltage suppressor
and light

voltage suppressor

surge voltage
suppressor and light

terminal, surge
voltage suppressor
and light

DO - For DIN terminal (without connector,


gasket is included.)

DIN type is available with class B only.


Refer to Table (3) for available combinations between each electrical option
(S, L, Z) and rated voltage.
Surge voltage suppressor is integrated into the AC/Class B coil, as a standard.

Table (1) Model/Orifice Diameter/Port Size


Model
Port
symbol
(Port size)

VX31

VX32

VX33

01 (1/8)
02 (1/4)

02 (1/4)
03 (3/8)

02 (1/4)
03 (3/8)

Table (3) Rated Voltage Electrical Option

Orifice symbol (Diameter)

Solenoid valve model

VXS
VXP

Thread type
Nil

VXZ
VXE

Refer to Table (1) shown below for availability.

Nil

VXD

Table (2) Solenoid Valve Option


Seal material
Body material/
Coil
Option
Guide pin
Main valve Fixed Shading coil
insulation
symbol
material
material
poppet sealant
type
Nil
Brass (C37)
NBR
NBR
Stainless
G
steel
PPS
B
Stainless
M
steel
FKM
FKM
V
Brass (C37)

Rated voltage

(1.5 mm) (2.2 mm) (3 mm) (4 mm)

AC/
DC

AC
Note Note)

Non-leak
(106 Pam3/sec),
Medium vacuum
(0.1 Pa.abs), Oil-free

DC

Voltage
symbol

1
2
3
4
7
8
J
5
6

Class B

With surge
voltage
Voltage
suppressor
100 V
200 V
110 V
220 V
240 V
48 V
230 V
24 V
12 V

With
light

With light and


surge voltage
suppressor

Note)

Note)

Note 1) Option S, Z are not available as surge voltage suppressor is


integrated into the AC/Class B coil, as a standard.
Class H coil is not available.

Note) The leakage amount (106 Pam3/sec) for the V and M option are values
when the differential pressure is 0.1 MPa.

311

VXA

Series VVX31/32/33

For Air /Manifold


(Non-leak, Medium vacuum)

Solenoid Valve for Manifold / Valve Specifications


N.C.

N.O.

Symbol

COM.

Symbol
2

Symbol
2

Note) Symbols for N.C. and N.O. types


The symbols show that the N.C. type: port 3 and N.O. type: port 1 are in a blocked state (-1).
However, use each port pressure in the state shown below.
N.C. type: Pressure at port 1 Pressure at port 2 Pressure at port 3
N.O. type: Pressure at port 3 Pressure at port 2 Pressure at port 1

Orifice diameter
(mm)

N.C.
1
0.7
1.2
1.6
0.3
0.6
1
0.3
0.5

VX311-00
VX312-00
VX322-00
VX332-00
VX313-00
VX323-00
VX333-00
VX324-00
VX334-00

1.5
2.2

3
4

Flow characteristics

Max. operating pressure differential (MPa)

Model

N.O.
1
0.5
1
1.6
0.3
0.5
0.9
0.25
0.4

COM.
0.7
0.4
0.7
1
0.2
0.3
0.6
0.2
0.3

C[dm3/(sbar)]
0.29
0.60

b
0.32
0.25

Cv
0.08
0.15

0.64

0.40

0.17

0.82

0.20

0.20

1.1

0.25

0.27

1.6

0.20

0.38

Max. system
pressure
(MPa)

2.0

Refer to Glossary of Terms on page 331 for details on the max. operating pressure differential and the max. system pressure.

Fluid and Ambient Temperature

Valve Leakage Rate


Internal Leakage / External Leakage

Power source
AC
DC

Fluid temperature (C)


Solenoid valve option (symbol)
Nil

Ambient
temperature
(C)

10 Note) to 60
10 Note) to 60

10 Note) to 40
10 Note) to 40

20 to 60
20 to 40

Note) Dew point temperature: 10C or less

312

Seal material
NBR, FKM

Leakage rate
Non-leak, Medium
vacuum Note)
From 0 to less than 1 MPa 1 cm3/min or less 106 Pam3/sec
3
or less
1 MPa or more
2 cm /min or less
Max. operating
pressure differential

Air

Note) The leakage amount (106 Pam3/sec) for the V option are values
when the differential pressure is 0.1 MPa.

Direct Operated 3 Port Solenoid Valve

Series VVX31/32/33
For Air / Manifold

How to Order (Solenoid Valve for Manifold)

VX 31 1 1
VX 31 1 1

DC
AC/Class B coil (Built-in
full-wave rectifier type)
Model

Orifice diameter

Refer to Table (1) shown


below for availability.

1
3
5

Refer to Table (2) shown


below for availability.

Rated voltage
1
2
3
4
5

6
7
8
J

100 VAC 50/60 Hz


200 VAC 50/60 Hz
110 VAC 50/60 Hz
220 VAC 50/60 Hz
24 VDC

12 VDC
240 VAC 50/60 Hz
48 VAC 50/60 Hz
230 VAC 50/60 Hz

Refer to page 329 for ordering coil only.

C - Conduit

VXE

T - With conduit terminal


TS - With conduit terminal and surge

D - DIN terminal
DS - DIN terminal with surge voltage

TL - With conduit terminal and light


TZ - With conduit terminal, surge

DL - DIN terminal with light


DZ - DIN terminal with surge voltage

voltage suppressor and light

Number of
manifolds

Port size (Individual port)

02

2 stations

1
2

10

10 stations

Rc 1/8
Rc 1/4

Suffix

Common port sizes are all Rc 1/4.


Indicating numbers shown below
are for common ports.

Type
N.C.
N.O.

SUP port
1
3

Nil

EXH port
3
1

Oil-free spec.

Blanking plate part no.

VVX31-4AFor VX31:
For VX32/33: VVX32-4ANil

NBR
FKM

How to Order Manifold Assemblies (Example)


Enter the valve and blanking plate to be mounted under the
manifold base part number.

Station

is the symbol for mounting.


Add an in front of the part numbers
for solenoid valves, etc. to be mounted.
4

VXF2
VX3

Orifice symbol (Diameter)

(3 mm)

(4 mm)

(1.5 mm) (2.2 mm)

VX31
VX32
VX33

Table (2) Solenoid Valve Option

Seal material

D side

VXH

Table (1) Model/Orifice Diameter

Nil

Example
VVX311-05-1 ..... 1 set
VX3111-00-1GR1 ... 4 sets
VVX31-4A ........... 1 set

suppressor and light

DO - For DIN terminal

Seal material
Coil
Option
Body Guide pin
insulation
Main valve Fixed
symbol
material material
type
poppet sealant

Manifold base

VXR

DIN type is available with class B only.


Refer to Table (3) for available combinations between each electrical option
(S, L, Z) and rated voltage.
Surge voltage suppressor is integrated into the AC/Class B coil, as a standard.

Solenoid
valve
model

U side

Enter the products part


number in order, counting the 1st station from
the left in the manifold
arrangement, when viewing the individual port in
front.
The common port on the
right side is plugged.

NBR

Note Note)

NBR

FKM

FKM

Brass
(C37)

PPS

Non-leak (106 Pam3/


sec), Medium vacuum
(0.1 Pa.abs), Oil-free

Aluminum is only available as a material for the manifold base.

Note) The leakage amount (106 Pam3/sec) for the Voption are values when
the differential pressure is 0.1 MPa.

Table (3) Rated Voltage Electrical Option


Class B

Rated voltage
AC/
DC

AC

DC

Voltage
symbol

1
2
3
4
7
8
J
5
6

With surge
voltage
Voltage
suppressor
100 V
200 V
110 V
220 V
240 V
48 V
230 V
24 V
12 V

With
light

With light and


surge voltage
suppressor

Note)

VXP

suppressor

(without connector,
gasket is
included.)

07 1

VXZ
VXS

surge voltage
suppressor

How to Order Manifold Bases

VVX31
VVX32 1
VVX33

VXD

Electrical entry

G - Grommet
GS- With grommet

voltage suppressor

Refer to Table (3) shown below for availability.

VXK

Oil-free spec.

Nil

Solenoid valve option

N.C. / Manifold
N.O. / Manifold
COM. / Manifold

VX2

Built-in full-wave
rectifier type

Suffix

Refer to Table (1) shown


below for availability.

Valve / Body type

00 5 G 1
00 1 G R1

Note)

Class H coil is not available.


Note) Option S, Z are not available as surge voltage suppressor is
integrated into the AC/Class B coil, as a standard.

313

VXA

Series VX31/32/33

For Water /Single Unit


Model / Valve Specifications
N.C.
Symbol

N.O.
Symbol

1 3

COM.
Symbol

1 3

1 3

Note) Symbols for N.C. and N.O. types


The symbols show that the N.C. type: port 3 and N.O. type: port 1 are in a blocked state (-1).
However, use each port pressure in the state shown below.
N.C. type: Pressure at port 1 Pressure at port 2 Pressure at port 3
N.O. type: Pressure at port 3 Pressure at port 2 Pressure at port 1

Port size

Orifice
diameter
(mm)

1/8
(6A)

1.5
2.2
3
1.5
2.2

1/4
(8A)
3
4
2.2
3/8
(10A)

3
4

Model
VX311-01
VX312-01
VX313-01
VX311-02
VX312-02
VX322-02
VX332-02
VX313-02
VX323-02
VX333-02
VX324-02
VX334-02
VX322-03
VX332-03
VX323-03
VX333-03
VX324-03
VX334-03

Max. operating pressure differential (MPa)


N.C.
1
0.7
0.3
1
0.7
1.2
1.6
0.3
0.6
1
0.3
0.5
1.2
1.6
0.6
1
0.3
0.5

N.O.
1
0.5
0.3
1
0.5
1
1.6
0.3
0.5
0.9
0.25
0.4
1
1.6
0.5
0.9
0.25
0.4

COM.
0.7
0.4
0.2
0.7
0.4
0.7
1
0.2
0.3
0.6
0.2
0.3
0.7
1
0.3
0.6
0.2
0.3

Flow characteristics
Av x 10-6m2
1.9
3.8
5.8
1.9
3.8

Cv converted
0.08
0.16
0.24
0.08
0.16

4.6

0.19

5.8

0.24

7.9

0.33

12

0.50

4.6

0.19

7.9

0.33

12

Max. system
pressure
(MPa)

0.50

Note)

Weight
(g)

380

2.0

530
730
380
530
730
530
730
530
730
530
730
530
730

Note) Weight of grommet type. Add 10 g for conduit, 30 g for DIN terminal, and 60 g for conduit terminal type respectively.
Also, add 60 g for VX31, 80 g for VX32 and VX33 respectively for bracket option.
Refer to Glossary of Terms on page 331, for details on the max. operating pressure differential and the max. system pressure.

Fluid and Ambient Temperature

Valve Leakage Rate


Internal Leakage / External Leakage

Power source
AC
DC
Note) With no freezing

314

Fluid temperature (C)


Solenoid valve option (Symbol)
E, P
Nil, G, H
1 to 60
1 to 99
1 to 40

Ambient
temperature
(C)
20 to 60
20 to 40

Seal material

Max. operating
pressure differential

From 0 to less than 1 MPa


NBR, FKM, EPDM
1 MPa or more

Leakage rate (Water)


0.1 cm3/min or less
0.2 cm3/min or less

Direct Operated 3 Port Solenoid Valve

Series VX31/32/33
For Water / Single Unit

How to Order (Single Unit)

VX 31 1 4
VX 31 1 4

DC, AC/Class H coil


AC/Class B coil (Built-in
full-wave rectifier type)

1 G 1
1 G R1

Orifice diameter

Bracket

Refer to Table (1) shown


below for availability.

Nil

Valve / Body type

Refer to Table (2) shown


below for availability.

Built-in full-wave
rectifier type

Port size
Refer to Table (1) shown below for availability.

Thread type
Nil

Suffix
Z

Oil-free spec.

100 VAC 50/60 Hz


200 VAC 50/60 Hz
110 VAC 50/60 Hz
220 VAC 50/60 Hz
24 VDC

6
7
8
J

C - Conduit

T - With conduit terminal


TS - With conduit terminal and

D - DIN terminal
DS - DIN terminal with surge

surge voltage suppressor


TL - With conduit terminal
and light
TZ - With conduit
terminal, surge
voltage suppressor
and light

Refer to Table (3) shown below for availability.

Refer to page 329 for ordering coil only.

Connector

voltage suppressor
DL - DIN terminal with light
DZ - DIN terminal with
surge voltage
suppressor and light
DO - For DIN terminal (without connector,
gasket is included.)
DIN type is available with class B only.

Refer to Table (3) for available combinations between each electrical option
(S, L, Z) and rated voltage.
Surge voltage suppressor is integrated into the AC/Class B coil, as a standard.

Table (3) Rated Voltage Electrical Option

Table (1) Model/Orifice Diameter/Port Size


Model
Port
symbol
(Port size)

VX31

VX32

Orifice symbol (Diameter)

VX33

(3 mm)

(4 mm)

(1.5 mm) (2.2 mm)

01 (1/8)
02 (1/4)

02 (1/4)
03 (3/8)

02 (1/4)
03 (3/8)

Nil

G
E
P
H

NBR

NBR

EPDM

EPDM

FKM

FKM

Body material/
Shading coil
material

AC/
DC

Guide pin
material

Brass (C37)
PPS
Stainless steel
Brass (C37)/Cu Stainless
steel
Stainless steel/Ag
PPS
Stainless steel

Coil
insulation
type

Note

Heated water

Voltage
Voltage
symbol

1
2
3
4
7
8
J
5
6

AC

Table (2) Solenoid Valve Option


Option
symbol

Rated voltage

Seal material
Main valve
Fixed
poppet
sealant

VXS
VXP
VXH

12 VDC
240 VAC 50/60 Hz
48 VAC 50/60 Hz
230 VAC 50/60 Hz

Solenoid valve model

VXZ

VXR

voltage suppressor

Rated voltage
1
2
3
4
5

G - Grommet
GS- With grommet surge

VXD

VXE

Electrical entry

Rc
NPTF
G
NPT

T
F
N

None
With bracket

Bracket is neither
mountable nor removable.

Solenoid valve option

N.C. / Single unit


N.O. / Single unit
COM. / Single unit

Nil

VX2
VXK

Model
Refer to Table (1) shown
below for availability.

0
2
4

01
01

DC

100 V
200 V
110 V
220 V
240 V
48 V
230 V
24 V
12 V

Class B

With surge
voltage
suppressor

With
light

With light and


surge voltage
suppressor

Note)

Note)

Note) Option S, Z are not available as surge voltage suppressor is


integrated into the AC/Class B coil, as a standard.

Rated voltage
AC/
DC

AC

DC

Voltage
Voltage
symbol

1
2
3
4
7
8
J
5
6

100 V
200 V
110 V
220 V
240 V
48 V
230 V
24 V
12 V

Class H

With surge
voltage
suppressor

With
light

With light and


surge voltage
suppressor

DC specification is not available.

315

VXF2
VX3
VXA

Series VX31/32/33

For Oil /Single Unit


Model / Valve Specifications
N.C.
Symbol

N.O.
Symbol

1 3

COM.
Symbol

1 3

1 3

Note) Symbols for N.C. and N.O. types


The symbols show that the N.C. type: port 3 and N.O. type: port 1 are in a blocked state (-1).
However, use each port pressure in the state shown below.
N.C. type: Pressure at port 1 Pressure at port 2 Pressure at port 3
N.O. type: Pressure at port 3 Pressure at port 2 Pressure at port 1

Port size

Orifice
diameter
(mm)

1/8
(6A)

2.2
1/4
(8A)
3
4
2.2
3/8
(10A)

N.C.
1
0.7
0.3
1
0.7
1.2
1.6
0.3
0.6
1
0.3
0.5
1.2
1.6
0.6
1
0.3
0.5

VX311-01
VX312-01
VX313-01
VX311-02
VX312-02
VX322-02
VX332-02
VX313-02
VX323-02
VX333-02
VX324-02
VX334-02
VX322-03
VX332-03
VX323-03
VX333-03
VX324-03
VX334-03

1.5
2.2
3
1.5

3
4

Flow characteristics

Max. operating pressure differential (MPa)

Model

N.O.
1
0.5
0.3
1
0.5
1
1.6
0.3
0.5
0.9
0.25
0.4
1
1.6
0.5
0.9
0.25
0.4

COM.
0.7
0.4
0.2
0.7
0.4
0.7
1
0.2
0.3
0.6
0.2
0.3
0.7
1
0.3
0.6
0.2
0.3

Av x 10-6m2
1.9
3.8
5.8
1.9
3.8

Cv converted
0.08
0.16
0.24
0.08
0.16

4.6

0.19

5.8

0.24

7.9

0.33

12

0.50

4.6

0.19

7.9

0.33

12

Max. system
pressure
(MPa)

0.50

Note)

Weight
(g)

380

2.0

530
730
380
530
730
530
730
530
730
530
730
530
730

Note) Weight of grommet type. Add 10 g for conduit, 30 g for DIN terminal, and 60 g for conduit terminal type respectively.
Also, add 60 g for VX31, 80 g for VX32 and VX33 respectively for bracket option.
Refer to Glossary of Terms on page 331, for details on the max. operating pressure differential and the max. system pressure.

Fluid and Ambient Temperature

Valve Leakage Rate


Internal Leakage / External Leakage

Power source
AC
DC

Fluid temperature (C)


Solenoid valve option (Symbol)

A, H

D, N

Ambient
temperature
(C)

5 Note) to 60
5 Note) to 40

5 Note) to 120

20 to 60
20 to 40

Note) Dynamic viscosity: 50 mm2/s or less

316

Seal material

Max. operating
pressure differential

Leakage rate (Oil)

FKM

From 0 to less than 1 MPa


1 MPa or more

0.1 cm3/min or less


0.2 cm3/min or less

Direct Operated 3 Port Solenoid Valve

Series VX31/32/33
For Oil / Single Unit

How to Order (Single Unit)

VX 31 1 4 A
VX 31 1 4 A

DC, AC/Class H coil


AC/Class B coil (Built-in
full-wave rectifier type)

5 G 1
1 G R1

Orifice diameter

Bracket

Refer to Table (1) shown


below for availability.

Valve / Body type

Nil

Solenoid valve option

N.C. / Single unit


N.O. / Single unit
COM. / Single unit

Refer to Table (1) shown below for availability.

Nil

Oil-free spec.

6
7
8
J

100 VAC 50/60 Hz


200 VAC 50/60 Hz
110 VAC 50/60 Hz
220 VAC 50/60 Hz
24 VDC

C - Conduit

T - With conduit terminal


TS - With conduit terminal and

D - DIN terminal
DS - DIN terminal with surge

VXH

12 VDC
240 VAC 50/60 Hz
48 VAC 50/60 Hz
230 VAC 50/60 Hz

surge voltage suppressor


TL - With conduit terminal
and light
TZ - With conduit
terminal, surge
voltage suppressor
and light

Refer to Table (3) shown below for availability.

Refer to page 329 for ordering coil only.

Connector

voltage suppressor
DL - DIN terminal with light
DZ - DIN terminal with
surge voltage
suppressor and light
DO - For DIN terminal (without connector,
gasket is included.)
DIN type is available with class B only.

Refer to Table (3) for available combinations between each electrical option
(S, L, Z) and rated voltage.
Surge voltage suppressor is integrated into the AC/Class B coil, as a standard.

Table (1) Model/Orifice Diameter/Port Size


Model
Port
symbol
(Port size)

VX31

VX32

Table (3) Rated Voltage Electrical Option


Orifice symbol (Diameter)

Solenoid valve model

VX33

(3 mm)

(4 mm)

(1.5 mm) (2.2 mm)

01 (1/8)
02 (1/4)

02 (1/4)
03 (3/8)

02 (1/4)
03 (3/8)

A
H
D
N

Seal material
Main valve
Fixed
poppet
sealant

FKM

FKM

Rated voltage

AC/
DC

Body material/
Shading coil
material
Brass (C37)
Stainless steel
Brass (C37)/Cu
Stainless steel/Ag

Guide pin
material

Coil
insulation
type

PPS

Stainless
steel

Voltage
Voltage
symbol

1
2
3
4
7
8
J
5
6

AC

Table (2) Solenoid Valve Option


Option
symbol

VXP
VXR

voltage suppressor

Rated voltage
1
2
3
4
5

G - Grommet
GS- With grommet surge

VXZ
VXE

Electrical entry

Rc
NPTF
G
NPT

T
F
N

VXD
VXS

Built-in full-wave
rectifier type

Thread type
Suffix

None
With bracket

Bracket is neither
mountable nor
removable.

Refer to Table (2) shown


below for availability.

Port size

Nil

VX2
VXK

Model
Refer to Table (1) shown
below for availability.

0
2
4

01
01

DC

100 V
200 V
110 V
220 V
240 V
48 V
230 V
24 V
12 V

Class B

With surge
voltage
suppressor

With
light

With light and


surge voltage
suppressor

Note)

Note)

Note) Option S, Z are not available as surge voltage suppressor is


integrated into the AC/Class B coil, as a standard.

The additives contained in oil are different depending on the type and manufacturers,
so the durability of the seal materials will vary. For details, please consult with SMC.

Rated voltage
AC/
DC

AC

DC

Voltage
Voltage
symbol

1
2
3
4
7
8
J
5
6

100 V
200 V
110 V
220 V
240 V
48 V
230 V
24 V
12 V

Class H

With surge
voltage
suppressor

With
light

With light and


surge voltage
suppressor

DC specification is not available.

317

VXF2
VX3
VXA

Series VVX31/32/33

For Oil /Manifold


Solenoid Valve for Manifold / Valve Specifications
N.C.

N.O.

Symbol

COM.

Symbol
2

Symbol
2

Note) Symbols for N.C. and N.O. types


The symbols show that the N.C. type: port 3 and N.O. type: port 1 are in a blocked state (-1).
However, use each port pressure in the state shown below.
N.C. type: Pressure at port 1 Pressure at port 2 Pressure at port 3
N.O. type: Pressure at port 3 Pressure at port 2 Pressure at port 1

Orifice diameter
(mm)

Max. operating pressure differential (MPa)

Model
VX311-00
VX312-00
VX322-00
VX332-00
VX313-00
VX323-00
VX333-00
VX324-00
VX334-00

1.5
2.2

3
4

N.O.
1
0.5
1
1.6
0.3
0.5
0.9
0.25
0.4

N.C.
1
0.7
1.2
1.6
0.3
0.6
1
0.3
0.5

COM.
0.7
0.4
0.7
1
0.2
0.3
0.6
0.2
0.3

Flow characteristics
Av x 10-6m2
1.9
3.8

Cv converted
0.08
0.16

4.6

0.19

5.8

0.24

7.9

0.33

12

Max. system
pressure
(MPa)

2.0

0.50

Refer to Glossary of Terms on page 331 for details on the max. operating pressure differential and the max. system pressure.

Fluid and Ambient Temperature

Valve Leakage Rate


Internal Leakage / External Leakage

Power source
AC
DC

Fluid temperature (C)


Solenoid valve option (Symbol)

Ambient
temperature
(C)

5 Note) to 60
5 Note) to 40

5 Note) to 120

20 to 60
20 to 40

Note) Dynamic viscosity: 50

318

mm2/s

or less

Seal material

Max. operating
pressure differential

Leakage rate (Oil)

FKM

From 0 to less than 1 MPa


1 MPa or more

0.1 cm3/min or less


0.2 cm3/min or less

Direct Operated 3 Port Solenoid Valve

Series VVX31/32/33
For Oil / Manifold

How to Order (Solenoid Valve for Manifold)

VX 31 1 1 A
VX 31 1 1 A

DC, AC/Class H coil


AC/Class B coil (Built-in
full-wave rectifier type)

00 5 G 1
00 1 G R1
Built-in full-wave rectifier type

Model

Electrical entry

Orifice diameter

Refer to Table (1) shown


below for availability.

G - Grommet
GS- With grommet surge voltage

VXZ

suppressor

Solenoid valve option

N.C. / Manifold
N.O. / Manifold
COM. / Manifold

Refer to Table (2) shown


below for availability.

VXS
D - DIN terminal
DS - DIN terminal with surge

Rated voltage
1
2
3
4
5

Suffix

Oil-free spec.

Nil

100 VAC 50/60 Hz


200 VAC 50/60 Hz
110 VAC 50/60 Hz
220 VAC 50/60 Hz
24 VDC

6
7
8
J

voltage suppressor
DL - DIN terminal with light
T - With conduit terminal
DZ - DIN terminal with
TS - With conduit terminal and
surge voltage
surge voltage suppressor
suppressor and light
TL - With conduit terminal and
DO - For DIN terminal (without
light
connector, gasket is
TZ - With conduit terminal, surge
included.)
voltage suppressor and light

12 VDC
240 VAC 50/60 Hz
48 VAC 50/60 Hz
230 VAC 50/60 Hz

Refer to Table (3) shown below for availability.

Refer to page 329 for ordering coil only.

Refer to Table (3) for available combinations between each


electrical option (S, L, Z) and rated voltage.
Surge voltage suppressor is integrated into the AC/Class B
coil, as a standard.

07 1
Number of
manifolds

Suffix

Oil-free spec.

Nil

02

2 stations

10

10 stations

Port size (Individual port)


1
2

Rc 1/8
Rc 1/4

Common port sizes are all Rc 1/4.


Indicating numbers shown below are for common ports.

Type
N.C.
N.O.

SUP port
1
3

EXH port
3
1

Table (1) Model/Orifice/Diameter


Solenoid
valve
model

VX31
VX32
VX33

Enter the valve and blanking plate to be mounted under the


manifold base part number.

(4 mm)

Seal material
Main valve
Fixed
poppet
sealant

Option
symbol

FKM

How to Order Manifold Assemblies (Example)

(3 mm)

is the symbol for mounting.


Add an in front of the part numbers
for solenoid valves, etc. to be mounted.
4

Body material/
Shading coil
material

Guide pin
material

Coil
insulation
type

Brass (C37)

PPS

Brass (C37)/Cu

Stainless
steel

Aluminum is only available as a material for the manifold base.


The additives contained in oil are different depending on the type and manufacturers, so the durability of the seal materials will vary. For details, please consult with
SMC.

Table (3) Rated Voltage Electrical Entry Electrical Option


Class B

Rated voltage
AC/
DC

U side

Enter the products part


number in order, counting the 1st station from
the left in the manifold
arrangement, when viewing the individual port in
front.
The common port on the
right side is plugged.

FKM

Seal material: FKM

Station

Blanking plate part no.


For VX31:
VVX31-4A-F
For VX32/33: VVX32-4A-F

D side

Orifice symbol (Diameter)

(1.5 mm) (2.2 mm)

Table (2) Solenoid Valve Option

Example
VVX311-05-1 ........ 1 set
VX3111A-00-1GR1 .. 4 sets
VVX31-4A-F.......... 1 set

VXP
VXR
VXH
VX3

DIN type is available with


class B only.

Manifold base

VXE

VXF2

How to Order Manifold Bases

VVX31
VVX32 1
VVX33

VXK
VXD

C - Conduit

Refer to Table (1) shown


below for availability.

Valve / Body type


1
3
5

VX2

AC

DC

With surge
Voltage
Voltage voltage
symbol
suppressor

1
2
3
4
7
8
J
5
6

100 V
200 V
110 V
220 V
240 V
48 V
230 V
24 V
12 V

Note)

Class H

L
With
light

With light and With surge


surge voltage voltage
suppressor suppressor

With
light

With light and


surge voltage
suppressor

Note)

DC specification is not
available.

Note) Option S, Z are not available as surge voltage suppressor is integrated into the
AC/Class B coil, as a standard.

319

VXA

Series VX31/32/33

For Steam /Single Unit


Model / Valve Specifications
COM.
Symbol

1 3

Port size
1/8
(6A)

Orifice diameter
(mm)

Model

1.5
2.2
3
1.5

VX3114-01
VX3124-01
VX3134-01
VX3114-02
VX3124-02
VX3224-02
VX3324-02
VX3134-02
VX3234-02
VX3334-02
VX3244-02
VX3344-02
VX3224-03
VX3324-03
VX3234-03
VX3334-03
VX3244-03
VX3344-03

2.2
1/4
(8A)
3
4
2.2
3/8
(10A)

3
4

Max. operating pressure


differential (MPa)
COM.
0.7
0.4
0.2
0.7
0.4
0.7
1
0.2
0.3
0.6
0.2
0.3
0.7
1
0.3
0.6
0.2
0.3

Flow characteristics
Av x 10-6m2
1.9
3.8
5.8
1.9
3.8

Cv converted
0.08
0.16
0.24
0.08
0.16

4.6

0.19

5.8

0.24

7.9

0.33

12

0.50

4.6

0.19

7.9

0.33

12

0.50

Max. system
pressure
(MPa)

Note)

Weight
(g)

380

1.0

530
730
380
530
730
530
730
530
730
530
730
530
730

Note) Weight of grommet type. Add 10 g for conduit, 30 g for DIN terminal, and 60 g for conduit terminal type respectively.
Also, add 60 g for VX31, 80 g for VX32 and VX33 respectively for bracket option.
Refer to Glossary of Terms on page 331, for details on the max. operating pressure differential and the max. system pressure.

Fluid and Ambient Temperature

Valve Leakage Rate


Internal Leakage

Power source
AC

320

Fluid temperature (C)


Solenoid valve option (Symbol)

S, Q

Ambient
temperature
(C)

183

20 to 60

Seal material
FFKM

Leakage rate (Air)


150 cm3/min or less

External Leakage
Seal material
PTFE

Leakage rate (Air)


1 cm3/min or less

Direct Operated 3 Port Solenoid Valve

Series VX31/32/33
For Steam / Single Unit

How to Order (Single Unit)

VX 31 1 4 S

01

1 G1
VX2

Model
Refer to Table (1) shown
below for availability.

Bracket

Orifice diameter
Refer to Table (1) shown
below for availability.

Nil

Bracket is neither mountable


nor removable.

Valve / Body type


4

VXK

None
With bracket

B
COM. / Single unit

VXZ

Solenoid valve option


Refer to Table (2) shown
below for availability.

VXS
Port size

VXE

Refer to Table (1) shown below for availability.

Thread type
Nil

Suffix

Oil-free spec.

Nil

Electrical entry

Rc
NPTF
G
NPT

T
F
N

G - Grommet
GS- With grommet surge

C - Conduit

7
8
J

100 VAC 50/60 Hz


200 VAC 50/60 Hz
110 VAC 50/60 Hz
220 VAC 50/60 Hz

VXH
VXF2

T - With conduit terminal


TS - With conduit terminal and

240 VAC 50/60 Hz


48 VAC 50/60 Hz
230 VAC 50/60 Hz

surge voltage suppressor


TL - With conduit terminal
and light
TZ - With conduit
terminal, surge
voltage suppressor
and light

Refer to Table (3) shown below for availability.

Refer to page 329 for ordering coil only.

VX3
VXA

Refer to Table (3) for available combinations between each electrical option
(S, L, Z) and rated voltage.

Table (1) Model/Orifice Diameter/Port Size


Model
Port
symbol
(Port size)

VX31

VX32

Table (3) Rated Voltage Electrical Option


Orifice symbol (Diameter)

Solenoid valve model

VX33

(3 mm)

(4 mm)

(1.5 mm) (2.2 mm)

01 (1/8)
02 (1/4)

02 (1/4)
03 (3/8)

02 (1/4)
03 (3/8)

Option
symbol

S
Q

FFKM

PTFE

Body material/
Shading coil
material

AC/
DC

AC

Table (2) Solenoid Valve Option


Seal material
Main valve
Fixed
poppet
sealant

Rated voltage

Coil
Guide pin
insulation
material
type

Brass (C37)/Cu Stainless


steel
Stainless steel/Ag

DC

VXP
VXR

voltage suppressor

Rated voltage
1
2
3
4

VXD

Voltage
Voltage
symbol

1
2
3
4
7
8
J
5
6

100 V
200 V
110 V
220 V
240 V
48 V
230 V
24 V
12 V

Class H

With surge
voltage
suppressor

With
light

With light and


surge voltage
suppressor

DC specification is not available.

Solenoid coil: AC/Class H only

321

For Vacuum Pad / Single Unit

Series VXV31/32/33

Vacuum circuit side is suited for a large orifice. Supply pressure side is suited for high pressure
and a vacuum pad.
Construction and dimensions are the same as the VX3 series.

Model / Valve Specifications


N.C.

N.O.

Symbol (example)

Symbol (example)

Orifice diameter
(mm)

Port size

Model

Port 1 side Port 3 side


1/8
(6A)

1/4
(8A)

3/8
(10A)

3
1.5
3
1.5

1.5
3
1.5
3

2.2

2.2

2.2

2.2

VXV3130-01
VXV3132-01
VXV3130-02
VXV3132-02
VXV3240-02
VXV3340-02
VXV3242-02
VXV3342-02
VXV3240-03
VXV3340-03
VXV3242-03
VXV3342-03

Operating pressure
(MPa)

Passage: 1
3

Port 1 side Port 3 side

C[dm /
(sbar)]

Low vacuum 0 to 0.5


0 to 0.5 Low vacuum
Low vacuum 0 to 0.5
0 to 0.5 Low vacuum
0 to 0.5
Low vacuum
0 to 0.9
0 to 0.5
Low vacuum
0 to 0.9
0 to 0.5
Low vacuum
0 to 0.9
0 to 0.5
Low vacuum
0 to 0.9

0.82
0.29
0.82
0.29

0.20
0.32
0.20
0.32

1.6

0.20

Flow characteristics
Passage: 2
2
3

Cv

C[dm /
(sbar)]

Cv

0.20
0.08
0.20
0.08

0.29
0.82
0.29
0.82

0.32
0.20
0.32
0.20

0.08
0.20
0.08
0.20

0.38

0.64

0.40

0.17

Max.
system
pressure
(MPa)

380

2.0
0.64

0.40

0.17

1.6

0.20

0.38

1.6

0.20

0.38

0.64

0.40

0.17

0.64

0.40

0.17

1.6

0.20

0.38

Note) Weight of grommet type. Add 10 g for conduit, 30 g for DIN terminal, and 60 g for conduit terminal type respectively.
Also, add 60 g for VX31, 80 g for VX32 and VX33 respectively for bracket option.
Refer to Glossary of Terms on page 331, for details on the max. operating pressure differential and the max. system pressure.
Low vacuum: Up to 1.3 x 102Pa

Fluid and Ambient Temperature

Valve Leakage Rate


Internal Leakage / External Leakage

Power source

Fluid temperature (C)

Ambient
temperature (C)

AC
DC

10 Note) to 60
10 Note) to 60

20 to 60
20 to 40

Note 1) Dew point temperature: 10C or less

322

Seal material
NBR, FKM
Note) Value when air pressure is applied.

Note)

Weight
(g)

Leakage rate Note)


Air
1 cm3/min or less

530
730
530
730
530
730
530
730

Direct Operated 3 Port Solenoid Valve

Series VXV31/32/33
For Vacuum Pad / Single Unit

How to Order (Single Unit)

DC
AC/Class B coil (Built-in
full-wave rectifier type)

VXV 31 3 0
VXV 31 3 0

5 G 1
1 G R1

Orifice diameter

VXD

Refer to Table (1) shown


below for availability.

Valve / Body type


N.C. / Single unit
N.O. / Single unit

Bracket

Solenoid valve option

Nil

Refer to Table (2) shown


below for availability.

Refer to Table (1) shown below for availability.

Oil-free spec.

Nil

Rc
NPTF
G
NPT

T
F
N

VXP
VXH

Electrical entry
G - Grommet
GS- With grommet surge

C - Conduit

Refer to Table (3) shown below for availability.

T - With conduit terminal


TS - With conduit terminal and

Connector
D - DIN terminal
DS - DIN terminal with surge

Refer to page 329 for ordering coil only.

TL - With conduit terminal

DL - DIN terminal with light


DZ - DIN terminal with

100 VAC 50/60 Hz


200 VAC 50/60 Hz
110 VAC 50/60 Hz
220 VAC 50/60 Hz
24 VDC

6
7
8
J

12 VDC
240 VAC 50/60 Hz
48 VAC 50/60 Hz
230 VAC 50/60 Hz

VXF2

voltage suppressor

VX3
surge voltage suppressor

voltage suppressor

and light

TZ - With conduit

surge voltage
suppressor and light

terminal, surge
voltage suppressor
and light

DO - For DIN terminal (without connector,


gasket is included.)

DIN type is available with class B only.


Refer to Table (3) for available combinations between each electrical option
(S, L, Z) and rated voltage.
Surge voltage suppressor is integrated into the AC/Class B coil, as a standard.

Table (3) Rated Voltage Electrical Option

Table (1) Model/Orifice Diameter/Port Size


Orifice symbol (Diameter) Note)

Solenoid valve model


Model
Port
symbol
(Port size)

VXV31

VXV32

VXV33

(2.2/4 mm)

02 (1/4)
03 (3/8)

02 (1/4)
03 (3/8)

Rated voltage

(1.5/3 mm)

01 (1/8)
02 (1/4)

AC/
DC

AC

Note) The orifice diameter shown above are for the supply pressure side/
vacuum side port.

Table (2) Solenoid Valve Option


Seal material
Option
Main valve Fixed
symbol
sealant
poppet
Nil
NBR
NBR
A
FKM
FKM
G
NBR
NBR
H
FKM
FKM

Body material

Coil
Guide pin
insulation
material
type

Brass (C37)
PPS
Stainless steel

VXS

VXR

Rated voltage
1
2
3
4
5

VXZ
VXE

Built-in full-wave
rectifier type

Thread type

Suffix

None
With bracket

Bracket is neither mountable nor removable.

Port size

Nil

VX2
VXK

Model
Refer to Table (1) shown
below for availability.

0
2

01
01

DC

Class B

With surge
Voltage
voltage
Voltage
symbol
suppressor
1
100 V
200 V
2
110 V
3
220 V Note)
4
240 V
7
48 V
8
230 V
J

24 V
5

12 V
6

With
light

With light and


surge voltage
suppressor

Note)

Note) Option S, Z are not available as surge voltage


suppressor is integrated into the AC/Class B coil, as
a standard.
Class H coil is not available.

323

VXA

For Vacuum Pad / Manifold

Series VVXV31/32/33

Construction and dimensions are the same as those of the VVX3 series.

Model / Valve Specifications


N.C.

N.O.

Symbol (example)

Symbol (example)

Orifice diameter
(mm)
3
1.5

1.5
3

2.2

2.2

Operating pressure
(MPa)

Model

Port 1 side Port 3 side


VXV3131-00
VXV3133-00
VXV3241-00
VXV3341-00
VXV3243-00
VXV3343-00

Flow characteristics
Passage: 1
3

Passage: 2

2
3

Port 1 side Port 3 side

C[dm /
(sbar)]

Cv

C[dm /
(sbar)]

Cv

Low vacuum 0 to 0.5


0 to 0.5 Low vacuum
0 to 0.5
Low vacuum
0 to 0.9
0 to 0.5
Low vacuum
0 to 0.9

0.82
0.29

0.20
0.32

0.20
0.08

0.29
0.82

0.32
0.20

0.08
0.20

1.6

0.20

0.38

0.64

0.40

0.17

0.64

0.40

0.17

1.6

0.20

0.38

Max.
system
pressure
(MPa)

Refer to Glossary of Terms on page 26 for details on the max. operating pressure differential and the max. system pressure.
Low vacuum: Up to 1.3 x 102Pa

Fluid and Ambient Temperature

Valve Leakage Rate


Internal Leakage / External Leakage

Power source
AC
DC

Fluid temperature (C)


Note)

to 60
10
10 Note) to 60

Note 1) Dew point temperature: 10C or less

324

Ambient
temperature (C)
20 to 60
20 to 40

Seal material
NBR, FKM
Note) Value when air pressure is applied.

Leakage rate Note)


Air
1 cm3/min or less

2.0

Direct Operated 3 Port Solenoid Valve

Series VVXV31/32/33
For Vacuum Pad / Manifold

How to Order (Solenoid Valve for Manifold)

VXV 31 3 1
VXV 31 3 1

DC
AC/Class B coil (Built-in
full-wave rectifier type)
Model

Nil

Refer to Table (1) shown


below for availability.

Valve / Body type


1
3

Suffix

Orifice diameter

Refer to Table (1) shown


below for availability.

6
7
8
J

100 VAC 50/60 Hz


200 VAC 50/60 Hz
110 VAC 50/60 Hz
220 VAC 50/60 Hz
24 VDC

12 VDC
240 VAC 50/60 Hz
48 VAC 50/60 Hz
230 VAC 50/60 Hz

Refer to Table (3) shown below for availability.

How to Order Manifold Bases

VVX31
VVX32 1
VVX33

VXZ
G - Grommet
GS- With grommet

C - Conduit

T - With conduit terminal


TS - With conduit terminal and surge

D - DIN terminal
DS - DIN terminal with surge

Number of
manifolds

VXP
VXR

voltage suppressor
DL - DIN terminal with light
DZ - DIN terminal with surge voltage
suppressor and light
DO - For DIN terminal
(without
connector,
gasket is
included.)
DIN type is available with class B
only.

Port size (Individual port)

02

2 stations

Refer to Table (3) for available combinations between each electrical option
(S, L, Z) and rated voltage.
Surge voltage suppressor is integrated into the AC/Class B coil, as a standard.

1
2

10

10 stations

Table (1) Model/Orifice Diameter

Rc 1/8
Rc 1/4

Type
N.C.
N.O.

Suffix
Nil

Vacuum side port SUP side port


1
3
3
1

Oil-free spec.

Manifold base

Solenoid
valve
model

VXV31
VXV32
VXV33

Blanking plate part no.

Option
symbol

Nil

NBR
FKM

Nil

Example
VVX311-05-1 ........ 1 set
VXV3131-00-1GR1.. 4 sets
VVX31-4A ........... 1 set

is the symbol for mounting.


Add an in front of the part numbers
for solenoid valves, etc. to be mounted.
4

Seal material
Main valve
Fixed
poppet
sealant
NBR
NBR
FKM
FKM

Body material
Brass (C37)

Guide
Coil
pin
insulation
material
type
PPS

Table (3) Rated Voltage Electrical Option

Enter the valve and blanking plate to be mounted under the


manifold base part number.

(2.2/4 mm)

Aluminum is only available as a material for the manifold base.

How to Order Manifold Assemblies (Example)

(1.5/3 mm)

Table (2) Solenoid Valve Option

Seal material

Orifice symbol (Diameter) Note)

Note) The orifice diameter shows the supply pressure side/vacuum side.

VVX31-4AFor VXV31:
For VXV32/33: VVX32-4A-

Rated voltage
AC/
DC

U side

Enter the products part


number in order, counting the 1st station from
the left in the manifold
arrangement, when viewing the individual port in
front.
The common port on the
right side is plugged.

VXS
VXE

surge voltage
suppressor

07 1

Common port sizes are all Rc 1/4.


Indicating numbers shown below are for
common ports.

Station

VXD

Electrical entry

voltage suppressor
TL - With conduit terminal and light
TZ - With conduit terminal, surge
voltage suppressor and light

Refer to page 329 for ordering coil only.

D side

VXK

Built-in full-wave
rectifier type

Oil-free spec.

Refer to Table (2) shown below for availability.

Rated voltage

VX2

Solenoid valve option

N.C. / Manifold
N.O. / Manifold

1
2
3
4
5

00 5 G 1
00 1 G R1

AC

DC

Class B

With surge
Voltage
Voltage
voltage
symbol
suppressor
1
100 V
200 V
2
110 V
3
220 V
4
Note)
240 V
7
48 V
8
230 V
J

24 V
5

12 V
6

With
light

With surge
voltage
suppressor

Note)

Class H coil is not available.


Note) Option S, Z are not available as surge voltage suppressor is integrated into the
AC/Class B coil, as a standard.

325

VXH
VXF2
VX3
VXA

Series VX31/32/33
For Air, Water, Oil, Steam

Construction
Single unit
Body material: Brass (C37), Stainless steel

Manifold
Base material: Aluminum
Manifold body material: Brass (C37)

i
w
y
e

i
w
y
e

t
u

Port 1
(N.C. IN)
(N.O. EXH)

!1

!1

!2

Port 3
(N.C. EXH)
(N.O. IN)

Port 2
(N.C. OUT)
(N.O. OUT)

!2

Description

Body

Tube assembly Note)

Armature
assembly

Return spring

Nut

Solenoid coil

O-ring

Clip

Guide pin
assembly

12 Plate

Port 3
(N.C. EXH)
(N.O. IN)

Port 2
(N.C. OUT)
(N.O. OUT)

No.

Description

Standard

Option

Brass (C37)

Stainless steel

Stainless steel, Cu

Stainless steel, Ag

Tube assembly Note)

Stainless steel, C36, PTFE


(NBR)

Stainless steel, PTFE


(FKM, EPDM, FFKM)

Armature
assembly

Return spring

Brass (C37)/Ni plated

Nut

Class B molded

Class H molded

Solenoid coil

(NBR)

(FKM, EPDM, PTFE)

O-ring

Clip

Guide pin
assembly

Stainless steel

SK
PPS, C36 (NBR)

Stainless steel
(FKM, EPDM, FFKM)

Stainless steel
(NBR)

(FKM, EPDM, PTFE)


Stainless steel

Material
Brass (C37)
Stainless steel, Cu
Stainless steel, C36, PTFE
(NBR)

Stainless steel
Brass (C37)/Ni plated

Class B molded

Class H molded

(NBR)

14 Base

(FKM, EPDM)
SK
Stainless steel
(FKM, EPDM)

PPS, C36 (NBR)

Stainless steel
(NBR)

12 Plate
13 Gasket

Stainless steel, PTFE


(FKM, EPDM)

Brass (C37)

10 Support spring
11 O-ring

Option

Standard

Manifold body

Brass (C37)

The materials in parentheses are the seal materials.


Note) Cu and Ag are not applicable to the DC spec and to the AC spec with
built-in full-wave rectifier.

326

!0

Component Parts
Material

10 Support spring
11 O-ring

!3

Port 1
(N.C. IN)
(N.O. EXH)

!4

!0

Component Parts
No.

(FKM, EPDM)
Stainless steel

(NBR)

(FKM, EPDM)
Aluminum

The materials in parentheses are the seal materials.


Note) Cu is not applicable to the DC spec and to the AC spec with built-in
full-wave rectifier.

Series VX31/32/33

Direct Operated 3 Port Solenoid Valve

For Air, Water, Oil, Steam / Single Unit

Dimensions: Single Unit / Body Material: Brass (C37), Stainless Steel


Normally closed (N.C.) : VX310/VX320/VX330
Normally open (N.O.) : VX312/VX322/VX332
Common (COM.)
: VX314/VX324/VX334
Conduit: C

Grommet: G

Approx.
300

Approx.
280

G1/2

VX2

VXK
C

A
B1

VXZ
VXS

A
B1

B2

VXE
VXP

25

B2

VXD
3xP
Port size

3xP
Port size

Width
across
flats H

Width
across
flats H

25

DIN terminal: D

VXR

Conduit terminal: T
J
M

Cable 6 to 12
G1/2

VXH

D
J

34

VXF2

VXA

3xP
Port size

A
B1

B2

44

Width
across
flats H

3xP
Port size

25

VX3
Width
across
flats H

A
B1

B2

G1/2

With bracket

(mm)
Model
N.C., N.O., COM.
4 x 5.5
Mounting hole

VX31
VX31
VX32
VX33

R
S

Orifice
diameter

Port size

1.5, 2.2, 3
1.5, 2.2, 3
2.2, 3, 4
2.2, 3, 4

1/8
1/4
1/4, 3/8
1/4, 3/8

Electrical entry (AC/Class B)


Grommet

Conduit

DIN terminal

30

46

33
36

56 51.5 51 68.5 52 56.5 103.5 51 72.5 105


64.5 54 59.5 71 60.5 59 106 59.5 75 113

48.5 41

65.5 42

Conduit terminal

53.5 100.5 41

69.5

91.5

(mm)
Model
N.C., N.O., COM.

VX31
VX31
VX32
VX33

Orifice
diameter

Port size

1.5, 2.2, 3
1.5, 2.2, 3
2.2, 3, 4
2.2, 3, 4

1/8
1/4
1/4, 3/8
1/4, 3/8

Electrical entry (DC, AC/Class H)

B1 B2
22
24
24

36
41
42
42

18
76.5
20.5
21 90
21 98

Grommet

Conduit

DIN terminal

Conduit terminal

Bracket mounting

93

17.5

40

50

75.5

47
47

57
57

89
97

30

19

19.5

27

19.5 50

40

42.5 58.5 42

46.5

92

42.5 61

35
40

22
22

22.5
25

32
36

22.5 60
25.5 68.5

43
46

52.5 61.5 52 49.5


61 64 60.5 52

95
98

52.5 64 106.5 21
61 66.5 114.5 21

327

Series VVX31/32/33
For Air, Oil / Manifold

Dimensions: Manifold / Base Material: Aluminum


Normally closed (N.C.) :
Normally open (N.O.) : VVX31/VVX32/VVX33
Common (COM.)
:
N

33

Port indication

G1/2

D
A

2 x Rc1/4

44

25

2 x E
Mounting
hole

L2
L1

Stations

12

U side

Approx. 280

Approx. 300

D side

H
F

2 x E
Mounting hole

(mm)
Model

VVX31
VVX32
VVX33

Dimension

L1
L2
L1
L2

2
96
84
126
108

3
132
120
172
154

4
168
156
218
200

n (stations)
7
6
5
204 240 276
192 228 264
264 310 356
246 292 338

8
312
300
402
384

9
348
336
448
430

10
384
372
494
476
(mm)
Electrical entry (DC, AC/Class H)

Model

Grommet

VVX31
VVX32
VVX33

40
44
44

20
22
22

9
10
10

22
24
24

6.5
8.5
8.5

33
34
34

24
25
25

26
31
31

36
46
46

6
9
9

49
55
55

19.5
22.5
25

80.5
91
99.5

19.5
22.5
25.5

40
43
46

45.5
54
62

45
53.5
61.5

58.5
61.5
64

46.5
49.5
52

92
95
98

Conduit

DIN terminal

Conduit terminal

61
97
64
107.5
66.5 116
(mm)

Electrical entry (AC/Class B)

328

Model

Grommet

VVX31
VVX32
VVX33

30
33
36

48.5
51.5
54

44
52.5
60.5

45
53.5
61.5

65.5
68.5
71

Conduit

DIN terminal

Conduit terminal

53.5 100.5
56.5 103.5
59
106

69.5 95.5
72.5 106
75
114.5

Direct Operated 3 Port Solenoid Valve

Series VX31/32/33
For Air, Water, Oil, Steam

Replacement Parts

Solenoid coil assembly part no.

DC

AC/Class B coil (Built-in full-wave rectifier type)

VX02 1 N

VX02 1 N

5 G

Series
1
2
3

Series
1
2
3

VX31
VX32
VX33

1
2
3
4
7
8
J

24 VDC
12 VDC

Note 1) Refer to Table (1)


for available
combinations.

VX2
VXK

Rated voltage Note)

VX31
VX32
VX33

Rated voltage Note)


5
6

1 GR
100 VAC 50/60 Hz
200 VAC 50/60 Hz
110 VAC 50/60 Hz
220 VAC 50/60 Hz
240 VAC 50/60 Hz
48 VAC 50/60 Hz
230 VAC 50/60 Hz

VXD
VXZ
VXS

Note 1) Refer to Table (1) for


available combinations.

Electrical entry

VXE

Electrical entry

G - Grommet
GS- With grommet surge

C - Conduit

T - With conduit terminal


TS - With conduit terminal and

D - DIN terminal
DS - DIN terminal with surge

G - Grommet

voltage suppressor

C - Conduit

VXP
VXR

Connector
voltage suppressor
DL - DIN terminal with light
DZ - DIN terminal with surge
voltage suppressor
and light
DO - For DIN terminal
(without connector)

surge voltage suppressor


TL - With conduit terminal
and light
TZ - With conduit
terminal,
surge voltage
suppressor and
light

T - With conduit terminal


TL - With conduit terminal

D - DIN terminal
Connector
DL - DIN terminal with light
DO - For DIN terminal

and light

(without connector)

Refer to Table (1) for available combinations between each electrical option
and rated voltage.
Surge voltage suppressor is integrated into the AC/Class B coil, as a standard.

AC/Class H coil

Table (1) Rated Voltage Electrical Option

1 G H 2 Z

Series
1
2
3

VX31
VX32
VX33

Rated voltage
AC/
DC

AC

Rated voltage Note)


1
2
3
4
7
8
J

100 VAC 50/60 Hz


200 VAC 50/60 Hz
110 VAC 50/60 Hz
220 VAC 50/60 Hz
240 VAC 50/60 Hz
48 VAC 50/60 Hz
230 VAC 50/60 Hz

DC

1
2
3
4
7
8
J
5
6

100 V
200 V
110 V
220 V
240 V
48 V
230 V
24 V
12 V

Note)

L
With
light

Class H

With light and With surge


surge voltage voltage
suppressor suppressor

With
light

With light and


surge voltage
suppressor

Note)

DC specification is not
available.

Note) Option S, Z are not available since a surge voltage suppressor is


integrated into the AC/Class B coil, as a standard.
When changing coils, AC/DC are not interchangeable with each other, and
Class B and H coils are also not interchangeable with each other.

Note 1) Refer to Table (1) for


available combinations.

G - Grommet
GS- With grommet surge

Class B

With surge
Voltage
Voltage voltage
symbol
suppressor

VXF2
VX3

Refer to Table (1) for available combinations between each electrical option
and rated voltage.

VX02 1 N

VXH

Electrical entry
C - Conduit

voltage suppressor

T - With conduit terminal


TS - With conduit terminal and surge voltage suppressor
TL - With conduit terminal and light
TZ - With conduit terminal, surge voltage suppressor and
light

Refer to Table (1) for available combinations between each electrical option
and rated voltage.

329

VXA

Series VX31/32/33
For Air, Water, Oil, Steam

Replacement Parts

Name plate part no.

AZ-T-VX

Clip

Valve model
Enter by referring to
How to Order.

Name plate

Clip part no.

For VX31: VX021N-10

Solenoid coil

For VX32: VX022N-10


For VX33: VX023N-10

DIN connector part no.

Without electrical option


With electrical option

GDM2A
GDM2A
Electrical option

S
L
Z

With surge voltage suppressor


With light
With light and surge voltage suppressor

Refer to Table (1) for available combinations


between each electrical option (S, L, Z) and rated
voltage.

Rated voltage
1
2
5
6
15

100 VAC, 110 VAC


200 VAC, 220 VAC, 230 VAC, 240 VAC
24 VDC
12 VDC
48 VAC

Gasket part no. for DIN connector

VCW20-1-29-1

330

Series

VX3

Glossary of Terms
Pressure Terminology

Others

1. Maximum operating pressure differential

The maximum pressure differential (the difference between the inlet


and outlet pressure) which is allowed for operation. When the outlet
pressure is 0 MPa, this becomes the maximum operating pressure.

2. Minimum operating pressure differential

The minimum pressure differential (the difference between the inlet


pressure and outlet pressure) required to keep the main valve fully opened.

1. Material

VX2

NBR: Nitrile rubber


FKM: Fluororubber
EPDM: Ethylene propylene rubber
PTFE: Polytetrafluoroethylene resin
FFKM: Perfluoroelastomer

VXK
VXD

2. Oil-free treatment

The degreasing and washing of wetted parts.

3. Maximum system pressure


The maximum pressure that can be applied inside the pipelines
(line pressure).
(The pressure differential of the solenoid valve portion must be
less than the maximum operating pressure differential.)

4. Proof pressure

VXZ

3. Passage symbol

In the symbol (
) Port 1 (IN) and Port 2 (OUT) are shown in a
blocked condition ( ), but it is not possible to use the valve in
cases of reverse pressure, where the Port 2 pressure is higher
than the Port 1 pressure.

The pressure in which the valve must be withstood without a drop


in performance after holding for one minute under prescribed
pressure and returning to the operating pressure range. (value
under the prescribed conditions)

VXS
VXE
VXP
VXR
VXH

Electrical Terminology
1. Apparent power (VA)

VXF2

Volt-ampere is the product of voltage (V) and current (A).


Power consumption (W): For AC, W = VAcos. For DC, W = VA.
Note) cos shows power factor. cos = 0.6

VX3

2. Surge voltage
A high voltage which is momentarily generated by shutting off the
power in the shut-off area.

VXA

3. Enclosure
A degree of protection defined in the JIS C 0920: Waterproof test
of electric machinery/appliance and the degree of protection
against the intrusion of solid foreign objects.
Verify the degree of protection for each product.

IP
Second characteristic numeral
First characteristic numeral
First Characteristics:
Degrees of protection against solid foreign objects
0
1
2
3
4
5
6

Non-protected
Protected against solid foreign objects of 50 mm and greater
Protected against solid foreign objects of 12 mm and greater
Protected against solid foreign objects of 2.5 mm and greater
Protected against solid foreign objects of 1.0 mm and greater
Dust-protected
Dusttight

Second Characteristics:
Degrees of protection against water
0
1
2
3
4
5
6
7
8

Non-protected
Protected against vertically falling water drops
Protected against vertically falling water drops when enclosure tilted up to 15
Protected against rainfall when enclosure tilted up to 60
Protected against splashing water
Protected against water jets
Protected against powerful water jets
Protected against the effects of temporary immersion in water
Protected against the effects of continuous immersion in water

Dripproof type 1
Dripproof type 2
Rainproof type
Splashproof type
Low jetproof type
Strong jetproof type
Immersible type
Submersible type

Example) IP65: Dusttight, Low jetproof type


Low jetproof type means that no water intrudes inside an
equipment that could hinder from operating normally by means
of applying water for 3 minutes in the prescribed manner. Take
appropriate protection measures, since a device is not usable in
an environment where a droplet of water is splashed constantly.

331

VX3
2/3 Port Solenoid Valves for Fluid Control
Specific Product Precautions 1

Series

Be sure to read this before handling. For detailed precautions on each series, refer to the main text.

Selection

Wiring

1. Minimum operating pressure differential (VXED, VXP,


VXR)

3. Use voltage which is within 10% of the rated voltage.


In cases with a DC power supply where importance is
placed on responsiveness, stay within 5% of the rated
value. The voltage drop is the value in the lead wire
section connecting the coil.
4. When a surge from the solenoid affects the electrical
circuitry, install a surge voltage suppressor, etc., in
parallel with the solenoid. Or, adopt an option that comes
with the surge voltage protection circuit. (However, a
surge voltage occurs even if the surge voltage protection
circuit is used. For details, please consult with us.)

Warning

Caution

Select an appropriate valve size while referring to the solenoid


valve flow-rate characteristics.

Caution
1. Leakage voltage

Particularly when using a resistor in parallel with a switching element and


using a C-R element (surge voltage suppressor) to protect the switching
element, take note that leakage current will flow through the resistor, C-R
element, etc., creating a possible danger that the valve may not turn off.

Leakage current

Operating Precautions
SOL.

AC/Class B built-in full-wave rectifier coil: 10% or less of rated


voltage (VX3: 5% or less)
AC/Class B/H coil: 20% or less of rated voltage
DC coil: 2% or less of rated voltage

2. Selecting options

The fluid handled will differ depending on the valve options. Select
optimal options for the fluid.

3. When the fluid is oil.

The dynamic viscosity of the fluid must not exceed 50 mm2/s.


The special construction of the armature adopted in the built-in
full-wave rectifier type gives an improvement in OFF response by
providing clearance on the absorbed surface when it is switched ON.
Select the DC spec. or AC spec. built-in full-wave rectifier type when
the dynamic viscosity is higher than water or when the OFF response is
prioritized.

4. When used at low differential pressure (VXZ).

When used under the conditions with a differential pressure of less


than 10 kPa (0.01 MPa) and a circuit flow rate of less than 1,000
dm3/min., use Made to Order Specifications -X500B.

Piping

Caution

Electrical Connections

Caution
Grommet

Class H coil: AWG18 Insulator O.D. 2.2 mm


Class B coil: AWG20 Insulator O.D. 2.5 mm

Rated voltage
DC (Class B only)
100 VAC
200 VAC
Other AC

Lead wire color


w
q
Red
Black
Blue
Blue
Red
Red
Gray
Gray

There is no polarity.

DIN terminal (Class B only)

Since internal connections are as shown


below for the DIN terminal, make connections to the power supply accordingly.
Terminal no.
DIN terminal

1
+ ()

1:+
()

1. If a regulator and valve are connected directly, they


may vibrate together and cause chattering. Do not
connect directly.
2. If the cross-sectional area of piping for the fluid supply side is
restricted, operation will become unstable due to inadequate
pressure differential during valve operation. Use piping size
for the fluid supply side that is suited to the port size.
3. The behavior of the diaphragm valve becomes unstable under
the conditions that the circuit flow rate is restricted to 40% or
less of the maximum flow rate on the solenoid valve flow-rate
characteristics. This may cause unstable valve activation. So,
select a solenoid valve with an appropriate flow rate size
while carefully checking the circuit flow rate.

Warning
1. Make sure when using pilot type 2-port solenoid valves that the flow
direction is from 1 (IN) to 2 (OUT). The valve is designed based on a
flow direction of 1 (IN) to 2 (OUT) and harnesses the fluid pressure of
port 1 (IN) when the valve opens or closes. If reverse pressure (2
(OUT) to 1 (IN)) is applied, it may lead to a reduced service life or
cause damage to parts early on due to chattering or pulses from the
main valve (diaphragm, piston, etc.). If there is a possibility that
reverse pressure will be applied, take countermeasures by installing
the check valve, etc. at the downstream side.
When installing the check valve, allow ample space between the
valve and the check valve. If it is placed near the valve, it may cause
chattering and pulses in the main valve.

Power supply

Leakage voltage

OFF
R

Switching element

2:
(+)

2
(+)

There is no polarity.
Use compatible heavy duty cords with cable O.D. of 6 to 12 mm.
Use the tightening torques below for each section.

Connector

Binding head screw with flange


Tightening torque 0.5 to 0.6 Nm

Wiring

Caution
1. As a rule, use electrical wire with a cross sectional
area of 0.5 to 1.25 mm2 for wiring.
Furthermore, do not allow excessive force to be
applied to the lines.
2. Use electrical circuits which do not generate chattering
in their contacts.

332

Washer

Compatible cable Note)


(Cable O.D. 6 to 12 mm)

Rubber seal
Gasket

Binding head screw


Tightening torque 0.5 to 0.6 Nm

Note) For an outside cable diameter of 9 to 12 mm, remove the


internal parts of the rubber seal before using.

VX3
2/3 Port Solenoid Valves for Fluid Control
Specific Product Precautions 2

Series

Be sure to read this before handling. For detailed precautions on each series, refer to the main text.

Electrical Connections

Electrical Circuits

Caution

Caution
In the case of the conduit terminal, make connections according
to the marks shown below.
Use the tightening torques below for each section.
Properly seal the terminal connection (G1/2) with the special
wiring conduit, etc.

1
+

Grommet, Conduit,
Conduit terminal,
DIN type

1 (+, )

VXZ
SOL.

SOL.
2 (, +)

With surge voltage suppressor

Varistor

1 (+, )
SOL.

SOL.
Round head
combination screw
M3 Tightening torque
0.5 to 0.6 Nm

Conduit terminal

2 (, +)

2 (, +)

LED

With light

View A-A
(Internal connection diagram)

With light/surge voltage suppressor

For AC/Class B, the standard product is equipped with surge voltage suppressor.

When used as an IP65 equivalent, use seal (part no. VCW20-15-6)


to install the wiring conduit. Also, use the tightening torque below
for the conduit.

Grommet, Conduit,
Conduit terminal,
DIN type
Rectifier
Varistor

Varistor
Rectifier
element

1
Varistor

Class H coil: AWG18 Insulator O.D. 2.2 mm


Class B coil: AWG20 Insulator O.D. 2.5 mm
Lead wire

Conduit terminal,
DIN type

element

SOL.

SOL.
2

neon light

With light

Without electrical option


w
Seal (VCW20-15-6)

Wiring conduit
(Bore size G1/2
Tightening torque 0.5 to 0.6 Nm)

[AC, Class B/H Circuit]


Grommet, Conduit,
Conduit terminal

Grommet,
Conduit terminal
Varistor

Lead wire color

Rated voltage

1 (+, )

DC

Black

Red

100 VAC

Blue

Blue

200 VAC

Red

Red

Other AC

Gray

Gray

There is no polarity for DC.

Description

Part no.

Seal

VCW20-15-6

Note) Please order separately.

1 (+, )
SOL.

SOL.
2 (, +)

2 (, +)

Without electrical option

With surge voltage suppressor

Conduit terminal

Conduit terminal
Varistor

1 (+, )

1 (+, )
SOL.

SOL.
2 (, +)

With light

neon light

2 (, +)

VXR
VXH
VXF2

LED

[AC, Class B (Built-in full wave rectifier type) Circuit]


Conduit

VXE
VXP

Conduit terminal,
DIN type

1 (+, )

G1/2
Tightening
torque
0.5 to 0.6 Nm

VXS

2 (, +)

Without electrical option

VXD

Varistor

1 (+, )

VXK

Grommet, Conduit terminal,


DIN type

Conduit terminal,
DIN type

+ mark

mark

Terminal cover
Round head
combination screw
M3 Tightening torque
0.5 to 0.6 Nm

VX2

[DC circuit]

Conduit terminal

neon light

With light/surge voltage suppressor

333

VX3
VXA

S-ar putea să vă placă și