Contents
About Pro-face
Application Simulation
Decrease Start-up and Application Troubleshooting
Operation Security
Operator Safety and Project Security
Field Maintenance
Low Cost Field Upgrades
C E L E B R AT I N G
35+ Years
of Industrial
Automation
Solutions
About Pro-face
Delivering More...
We are the leading independent global supplier of visualization and data management
solutions for industrial applications.
We continue to set the standards for industrial solutions by offering the industrys
most extensive product offerings and the highest levels of connectivity and support.
Innovation
Value
Service
Inspection
Production
Evaluation test
Design / Development
Plan
Market research
Analysis
Investment Protection
No service/support contracts
Proof-of-concept support
Globally certified
Delivering Performance
Extensive product testing, highest quality components and global certifications guarantee years of
reliable service and performance. Our products are serviced and supported around the globe.
Tested
Certified
Dependable
Environmental Management
Certified
Application Flexibility
Straightforward Solutions
Pro-face EX
Visualization Solutions
Easy as 1, 2, 3
1 Choose Your Platform
2 Select Your HMI
3 Create Your Screens
at
IT r
0N
100
Array Enhancements
Dedicated HMI
Dedicated Operator Interfaces
AGP3000 Series
Touch Screen Displays with extensive
simultaneous multi-protocol connectivity.
The HMI to use for data sharing and data
acquisition applications. Includes, CF, video,
Ethernet, serial and USB connectivity.
AGP3000 SERIES
AST3000 Series
Touch Screen Displays with standard
features to support standalone machine
applications. Includes serial and USB
connectivity.
AST3000 SERIES
LT 3000 Series
HMI with integrated logic control
and touch display. A cost effective
approach for stand alone machines.
LT3000 SERIES
Drives
Motion Controllers
Temperature
Controllers
Office
Control
Open HMI
Factory
APL3000 SERIES
PS3000 SERIES
Scanners
PLCs
Vision Systems
PC Server Access
Ethernet
PLC Access
(Pass Through)
Standardized Tools
D e live ring
HMI Development
Va l u e
I n n
Simulation
Security
GP-Pro EX Software
Rich Functionality
delivers tools to
cut application design time significantly.
Features such as built-in logic
programming, video support, and extensive
3rd party connectivity.
are included
that lower maintenance and support costs.
Maintenance can be done with or without a
PC on site.
PG 10
M o re
Off-site Diagnostics
is a great use
of the simulation tool. OEMs and System
integrators will find this invaluable as they
attempt service and support at the enduser site.
PG 19
PG 20
Internet
FTP/Webserver
Access
(Remote Access)
Security
Office
Ethernet
ovat ion
Security
Remote Access
Maintenance
Ease of Use
Data Sharing
Remote Support
Pro-Server EX Software
Select the right tool that meets the application need. Access, monitor, control
and upgrade the HMI over the internet.
Full service and support functionality.
PG 22
from HMIs in different locations. This benefit allows you to prioritize daily
machine maintenance activities.
PG 24
PG 28
Creating
Screens
Frequently-used functions
can be assigned to function
keys, making mouse-free
editing possible.
Set up communications
Choose and set up PLC and third-party
devices effortlessly
System settings are logically arranged
and easy to find
2.
Design application/screens
Drag-and-drop addressing, parts
and colors
Efficient features to reduce
development time
Create consistent look and feel using the
user-defined templates
10
4. Download/transfer
Tamper-proof HMI application
password-protected project source
Networking:
Data sharing and
data management
Open Platform
Factory Floor
Office
11
HMI Application
Development
Project
Conversion &
Sharing
Project Converter
Parts Toolbox
Type (shape)
selection
Color selection
Pattern selection
0 - 256/interface lock/delay
Parts display
based on category
Color number
selection
Select from 65535
colors/256 colors/etc.
Part drawing ID
CAD files
Display CAD images
on the operator interface!
Microsoft
Visio
2003
2007
Pro-face converter
Register
multiple parts
and images as
one group!
12
Meters
1000s of Parts
OK/Cancel
Choice
Window
Screen
Library of Screens
Movable
Keypad
Clock Data
Change
Screen
Extensive Features
Alarm History
Display Screen
Multiple Trend
Graph Display
Feature
Pre-configured
Device Connections
Capturing USB
Storage Screen
Yokogawa
Electric
Corporation:
FA-M3
PLC Communication
Tester
Yaskawa
Electric
Corporation:
MP2300
A vast Resource
FAQs
Manuals
Sample downloads
Screen Development
techniques
HMI Learning Center
Download
sample parts
here
http://www.hmisource.com/otasuke/
13
HMI Application
Development
Screen
Creation
Move/Rotate Graphics
14
Input in Excel,
copy and paste
into GP-Pro EX.
Eliminates the need to individually create alarm messages using one message
among multiple devices (addresses) for standardization.(Requires 7.5 or
larger AGP3000 models with expanded memory option installed.)
Each device
name can be
added to the
message and
displayed.
Responds to
multiple
languages.
Addresses of
several devices
can be
registered in
one alarm
message.
The font and size of the text table and label of the
switch/lamp can be setup individually.
Japanese
Switch
display up to
8 blocks.
English
15
HMI Application
Development Solutions
Screen
Creation
Search/exchange
the logic programs
instruction vocabulary
and variables.
Alignment can be
performed all at
once using right/left
& up/down position
adjustments.
Canceling an
interruption in
CSV file
16
Block-structured Subroutine
Initialization logic, main logic and subroutines can
be blocked, enabling smooth editing.
Logic search/replace
Search or replace the
indefinite numbers of
logic with the search
window.
Logic Display
You can check the operation of a logic program within the
system on site.
Address Display
The logic address is displayed, enabling you to check
variable names and their current values.
Online Editing
You can change a logic program even while the control
function is operating without stopping work.
Directly control I/O device from the main unit (with special I/O)
Install an EX module and control I/O device*
Function
Bit operation
Memory operation
CF file operation
Send/receive data
Printer operation
Send data
Draw
Others
Tool
Conditional
Branching
Comparison
Operation
17
( Instruction Name/Instruction
Notation/Ladder Symbol )
Operation Instruction
Arithmetic Operation
Bit Basic
Normally
Open
Normally
Closed
NO
Add
NC
Subtract
Out
OUT
Negative
Out
OUTN
Set
SET
Reset
RST
ADD
<*P>
SUB
<*P>
Multiplication MUL
<*P>
Division
DIV
<*P>
Pulse Basic
Positive
Transition
Negative
Transition
Modulation
PT
NT
Increment
Program Control
Jump to
Subroutine
JMP
<*P>
JSR
<*P>
Return
RET
Jump
Repeat
number
of times
(For)
Repeat
number
of times
(NEXT)
FOR
NEXT
LABEL NAME
SUBROUTINE NAME
RET
FOR
S1
NEXT
Decrement
INV
Exit
EXIT
Power Bar
Control
PBC
Power Bar
Reset
PBR
Logic Wait
Instruction
LWA
Time
Subtraction
PBC
S1
D1
AND
<*P>
OR
<*P>
XOR
<*P>
NOT
<*P>
D1
MUL
S1
TP
LWA
Move
(Copy)
S1
TON
(ms) Q
PT
PT
Exchange
PT
Accumulate
Off Delay
Timer
PT
ET
TONA
(ms) Q
R
ET
TOFA
(ms) Q
R
ET
Counter Instruction
Up Counter
CTUD
<*P>
CTU
Q
MOD
S1
PV
CV
CTD
Q
PV
CV
CTUD
Q
UP QU
R
QD
PV CV
Arithmetic
Shift Right
S2
Rotate Left
NNE
MOV
<*P>
FLMV
<*P>
XCH
<*P>
SHL
<*P>
SHR
<*P>
SAL
<*P>
SAR
<*P>
ROL
<*P>
NNE
(<>)
S1
S2
Sine
SIN
<*P>
Cosine
COS
<*P>
Tangent
TAN
<*P>
Arc Sine
ASIN
<*P>
Arc Cosine
ACOS
<*P>
Convert Instruction
SIN
S1
D1
COS
Instructions for
starting
pulse output
Data Convert
S1
D1
BCD Convert
BCD
<*P>
BIN Convert
BIN
<*P>
Encode
ENCO
<*P>
Decode
DECO
<*P>
Convert to
Radian
RAD
<*P>
Degree
Convert
DEG
<*P>
Scale
SCL
<*P>
BCD
S1
TAN
S1
D1
D1
S1
DEC
S1
D1
S1
S1
D1
D1
DECO
S1
D1
Instructions for
starting PWM
output
JADD
S1
D1
S2
ATAN
S1
D1
RAD
S1
D1
D1
S2
AND
S1
D1
S2
Cotangent
COT
<*P>
COT
S1
D1
Exponential
EXP
<*P>
S1
Logarithm
LN
<*P>
S1
Log Base 10
LG10
<*P>
S1
EXP
D1
D1
S2
S1
LN
D1
Convert
Integer
to Float
I2F
<*P>
S1
Convert
Integer
to Real
I2R
<*P>
S1
Convert
Float
to Integer
F2I
<*P>
S1
Convert
Float
to Real
F2R
<*P>
S1
Convert
Real
to Integer
R2I
<*P>
S1
Convert
Real
to Float
R2F
<*P>
Convert
Seconds
H2S
<*P>
Convert
Seconds to
Time
S2H
<*P>
PLSQ
(CH1)
D1
PWMX
(CH1)
D1
PWMG
(CH1)
D1
PWM
(CH1)
D1
PWM
PWMQ
(CH1)
D1
Instructions for
making changes
HSCX
to high-speed
counter parameters
Instructions for
retrieving
HSCG
high-speed
counter parameters
D1
SCL
D1
Type Convert
OR
S1
DEG
S1
PLS
(CH1)
D1
PLS
Instructions for
stopping PWM PWMQ
output
JSUB
S1
PLSG
(CH1)
D1
Instructions for
making changes
to PWM output PWMX
parameters
Instructions for
retrieving PWM
PWMG
output
parameters
D1
ENCO
D1
ACOS
PLSY
(CH1)
D1
Instructions for
stopping
PLSQ
pulse output
BIN
D1
ASIN
PLSX
(CH1)
D1
Instructions for
retrieving pulse PLSG
output parameters
Trigonometric Function
INC
Instructions for
starting high-speed
counter
I2F
D1
HSCX
(CH1)
D1
HSCG
(CH1)
D1
HSC
(CH1)
D1
HSC
XOR
S1
D1
S2
LG10
D1
NOT
S1
S2
MOV
S1
BLMV
S1
Equal
EQ
EQ
(=)
S1
S2
D1
S2
FLMV
S1
Arithmetic Compare
D1
Greater Than
GT
GT
(>)
S1
S2
D1
S2
XCH
Greater Than
Or Equal To
GE
GE
(>=)
S1
S2
D1
D2
SHL
S1
D1
S2
Less Than
Less Than Or
Equal To
LT
LE
SHR
S1
D1
Not Equal
NE
S2
SAL
S1
SAR
S1
S1
S2
LE
(<=)
S1
S2
NE
(<>)
S1
S2
Time Compare
Equal
JEQ
JEQ
(=)
S1
S2
D1
S2
Time Compare
Greater Than
ROL
S1
LT
(<)
D1
S2
Instructions for
stopping high-speed HSCQ
counter
I2R
D1
Instructions for
verifying
"pulse catch"
input
F2I
D1
JGT
Time Compare
Greater Than
Or Equal To
JGE
Time Compare
Less Than
JLT
Time Compare
Less Than
Or Equal To
JLE
JGT
(>)
S1
S2
JGE
(>=)
HSCQ
(CH1)
D1
PCH
(CH1)
D1
PCH
Instructions for
clearing
PCHQ
"pulse catch" input
F2R
D1
PCHQ
(CH1)
D1
R2I
CAN driver
D1
R2F
S1
SDOR
(CAN)
S1 D1
D1
S2
S3
H2S
S1
D1
SDOW
(CAN)
S1 D1
S2
S3
S2H
S1
D1
D2
Slave check
DGMT
(CAN)
D1
Time Compare
D1
S2
Rotation
Time Read
JRD
<*P>
JRD
Time Set
JSET
<*P>
JSET
D1
S1
Rotate Right
Rotate Left
with
Carry Over
Rotate Right
with
Carry Over
NRD
NSET
<*P>
NSET
D1
S1
D1
RCL
<*P>
RCR
<*P>
S1
D1
S2
RCL
S1
D1
S2
RCR
S1
D1
S2
Function Instruction
Calculate Function
Sum
NRD
<*P>
ROR
<*P>
ROR
DGSL
(CAN)
S1 D1
DGSL
Logic processing
(logic time)
I/O driver
output
START
1 scan
( Min.10 ms )
Operation
display processing
S1
S2
Time Compare
Not Equal
JLT
(<)
S1
S2
JNE
JLE
(<=)
S1
S2
JNE
(<>)
Average
Square Root
SUM
<*P>
AVE
<*P>
SQRT
<*P>
SUM
S1
D1
S2
AVE
S1
D1
S2
SQRT
S1
D1
Date Compare
Equal
Date Compare
Greater Than
Date Compare
Greater Than
Or Equal To
Date Compare
Less Than
NEQ
NGE
NLT
Type
Bit variable
Y0000~Y0511
M0000~M7999
I0000~I0127
NEQ
(=)
Integer variable
NGT
(>)
S1
S2
NGE
(>=)
S1
S2
NLT
(<)
S1
S2
Q0000~Q0127
D0000~D7999
S1
S2
NGT
S1
S2
Date Compare
D1
Date Read/Write
18
Arithmetic
Shift Left
Date Compare
Not Equal
Instructions for
making changes
PLSX
to pulse
output parameters
Instructions for
making changes
to acceleration/ PLSY
deceleration pulse
NLE
(<=)
S1
S2
Time Read/Write
Date Set
Shift Right
D1
NLE
D1
R/W Instruction
Date Read
Shift Left
S1
S2
S3
Date Compare
Less Than
Or Equal To
Compare Instruction
D1
PID
DIV
S2
ET
TP
(ms) Q
PT
CTU
<*P>
PID
S1 D1
ET
TOF
(ms) Q
Accumulate
On Delay
TONA
Timer
TOFA
PID
BCNT
S1
D1
S2
Shift
Pulse Timer
BCNT
<*P>
S2
Transfer
S1
Compare Instruction
Date Compare
SUB
S1
PBR
Timer Instruction
TOF
JSUB
<*P>
Bit Conut
EXIT
Logical NOT
Off Delay
Timer
D1
S2
Logical Operation
Logical XOR
TON
DEC
<*P>
Logical OR
On Delay
Timer
INC
<*P>
ADD
S1
Time Operation
Logical AND
Inverse
MOD
<*P>
Function Instruction
Calculate Function
Float variable
F0000~F0127
Real variable
R0000~R0127
Timer variable
T0000~T0511
Counter variable
C0000~C0511
Date variable
N0000~N0063
Time variable
J0000~J0063
PID variable
U0000~U0007
Simulation
SimulationDecreases
DecreasesMachine
MachineStartup
Startup
and
andApplication
ApplicationTroubleshooting
TroubleshootingTime
Time
Verify
Verify
Performance
Performance
and
and
Operation
Operation
Without
Without
Hardware.
Hardware.
GP-Pro
GP-Pro
EXEX
HMI
HMI
Screen
Screen
and
and
Logic
Logic
Simulation
Simulation
A Pseudo-environment
A Pseudo-environment
created
created
on your
on your
PC.PC.
Prevent
Prevent
errors
errors
in operations
in operations
by allowing
by allowing
confirmation
confirmation
andand
debugging
debugging
before
before
transfer.
transfer.
Screen
Screen
Operation
Operation
Check
Check
I/OI/O
Operation
Operation
Check
Check
Confirm
Confirm
screen
screen
performance
performance
before
before
transfer
transfer
without
without
connecting
connecting
to PLC.
to PLC.
Check
Check
actions
actions
performed
performed
using
using
the the
touch
touch
panel
panel
installed
installed
by by
clicking
clicking
withwith
the the
mouse.
mouse.
Confirm
Confirm
current
current
values
values
for for
addresses
addresses
allocated
allocated
to I/O
to driver
I/O driver
terminal
terminal
in order
in order
to to
control
control
external
external
I/O. I/O.
Some
Some
I/O drivers
I/O drivers
allow
allow
switching
switching
between
between
ON/OFF
ON/OFF
statestate
or change
or change
current
current
values.
values.
Do a screen
Do a screen
capture
capture
to useto use
for creating
for creating
specifications.
specifications.
Controller
Controller
Address
Address
Check
Check
Display
Display
andand
editedit
the the
list of
listpresent
of present
values
values
of virtual
of virtual
connected
connected
devices.
devices.
Logic
Logic
Operation
Operation
Check
Check
Confirm
Confirm
present
present
values
values
andand
ON/OFF
ON/OFF
status
status
of symbol
of symbol
variables
variables
before
before
transferring
transferring
the the
project
project
file.file.
Minimize
Minimize
timetime
in in
logic
logic
program
program
debugging.
debugging.
Perform
Perform
Intuitive
Intuitive
operation
operation
debugging
debugging
using
using
the the
screen
screen
view
view
or or
logic
logic
view.
view.
Cross
Cross
Reference
Reference
CSV
CSV
Export
Export
Print
Print
outout
settings
settings
Output
Output
the the
list of
listused
of used
addresses
addresses
as aas
CSV
a CSV
file file
to to
perform
perform
a cross
a cross
reference
reference
check.
check.
YouYou
cancan
select
select
to to
output
output
either
either
individual
individual
screens
screens
or all
orscreens.
all screens.
Select
Select
andand
printprint
required
required
setup
setup
information
information
of the
of the
project
project
file.file.
Minimize
Minimize
documentation
documentation
labor.
labor.
Export
Export
to to
CSV CSV
file file
rtf format
rtf format
outputoutput
optionoption
19
Security Controls
Prevent Unauthorized Access
Security Controls Control Access Rights for Safety and User Tracking
A variety of security controls are available to allow operators access to select HMI screens while preventing unauthorized access to password protected screens such as recipes and alarm screens.
Quickly and easily change passwords for each machine operator. Passwords may be changed or added
using a CSV file on a USB memory stick!
Project Security
Increased
In
ncreased Safety
for
M
Machine
Operator
Security Maintenance
Supervisor can
make security
adjustments to
prevent accidents
Set passwords for each screen or script to prevent accidental unauthorized access. Use security features
to protect intellectual property rights.
No
copying
No
copying
No
copying
Setting passwords
No PC on site Required!
Use a USB memory stick for daily, weekly or monthly
security changes. Additionally perform part label
changes, transfer screens, set recipes or collect log
data from HMI.
Change
passwords
Change
label
Transfer
screens
Collect logs
Set recipes
Pass Through
Easily view and debug ladder logic using the operator interface. Connect to controller without opening
the panel via a USB front-mounted cable.
For
AGP3000 AST3000
APL3000* PS3000*
*WingGP required
Compatible
with
industrial-use
computers
PLCs
Ladder Tool
Operator Interface:
PLC
22
Ethe
r
net
Log data
Recipe data
USB
Serial
23
Operator Interface:
AGP3000 Series HMI with Ethernet (AGP3xx0)
File Storage:
CF Card or USB Memory (> 128 MB)
Development Software: GP-Pro EX V2.0 or later
FTP Client:
Filezilla, Internet Explorer, or similar
Network Connection: Open access to AGP static IP address
24
Remote
Monitoring
Selecting Remote
Tools for
Maintenanceand
Cost Alerts
Reduction
Efficiency and Optimization
WebServer RSS Feed alarm monitoring and launch GP-Viewer with browser
FREE WebServer provides OEMs , System Integrators and End-users to automatically receive alarm notifications through RSS feeds, or launch GP-Viewer to monitor the machine operator activities.
Alarm monitor
FTP/Webserver
Access
Operator Interface:
AGP3000 Series HMI with Ethernet (AGP3xx0)
Web Content Storage: CF Card or USB Memory (> 128 MB)
RSS Reader:
Optional, any 3rd party RSS reader
Development Software: GP-Pro EX V2.0 or later
Web Browser:
Internet Explorer, Mozilla, Firefox or Similar
Network Connection: Open access to AGP static IP address
Eth
ern
Monitor
production
site AGP
status on a
PC
et
Device monitor
25
Remote PC Access
Expands HMI Capability
Remote PC Access (RPA) The full power of a PC available to your HMI
Remote PC Access (RPA) brings full PC functionality to a dedicated operator interface. Open any document such as PDFs, CAD, JPEGs, etc. or hot link to the machine builders web site from the display
screen of the operator interface. Accesses a remote Server PC and eliminates the need for PC on the
factory floor.
Internet, E-mail, Manual Access, etc.
Remote PC Access
Interact with a remote server PC using the operator
interface. The Operator Interface shows the same PC
server display on its screen.
Web!
PDF!
Perform PC
operations at
production
site
rnet
Ethe
Only for Ethernet TFT HMIs with VGA graphics and higher
26
Currently
under
remote
access
Currently
under
remote
access
GP-Viewer Functionality
27
Reporting
Data Sharing
Collect productivity and maintenance reports from Pro-face HMIs via Ethernet network.
Download operating instructions, such as recipes, from an office computer to a Pro-face Operator Interface.
For
APL3000/ PS3000
(WinGP required)
Office
User application
development
OPC support
EXCEL
VB / VC
SCADA etc
DDE server
DLL API
OPC DA server
Data copy
Data
management
SQL Server
Oracle
Mail
transmission
Excel action
Database action
Mail action
Mail server
CSV saving
JPEG capture
Application
activation
Other actions
Action function
PC
Pro-Server EX
Ethernet
Data
Collection
Data
Distribution
Vista
Compatible
Document output
Recipe saving
Log collection
EXCEL
Recipe
AGP
AGP
AGP
AGP
Factory
Data logging
A permanent PC is
not required for
peer-to-peer HMI
data sharing.
Reporting Results
Share information records using Excel
PLC of
PLC of
Company A Company B
Facility B
Facility C
Model: EX-MES-LICENSE-Vxx
MES Action
Action license for Pro-Server EX
28
Table
Data
MES Action
Pro-Server EX Ver.1.2
Real-time data (Cache)
Integrated
program
Settings
Daily
fluctuation graph
Reduction of man-hour
transition graph
Production control
template
Enhanced data
collection and
connectivity software
Applications
ata sharing with production
D
Collect and manage data
Up-to-the-minute
production data
Upstream status information
Necessary raw material
requirements
Snapshot images of machine
faults or instructions
Connectivity Support
OPC DA server
DDE
Enterprise
Data
FTP Server
Remote Monitoring Software
Local Data
Local Data
Per Machine Collection
Local Analysis
Planning - Materials
Scheduling - Resources
Maintenance - Machine requirements
Floor supervisor - Current status
Quality - Real-time charts
Plant manager - Key performance indicators
D
LL
A
PI (VB, VB.NET, VC, C#.NET)
A
ccess/Excel
O
DBC, SQL, Oracle
E-mail via SMTP
MES actions
29
Open
Operation
HMI
Maintenance
Solutions
APL3000/ PS3000
Inverter
Re-use HMI
applications
Temperature controller
Run a GP-Pro EX HMI application and communicate with various controllers using a
Pro-face industrial computer.
Programmable Display
Inter-device Communication
Supported Languages
Visual C++ Visual Basic C# VB.NET VBA
30
Industrial PC
AGP/LT/AST3000
PLC Drivers
Rockwell Automation
DF1
DH-485
EtherNet/IP:
SLC500/PLC5/MicroLogix
ControlLogix/CompactLogix
(Native-Tag base)
DeviceNet Slave
Siemens AG
SIMATIC S7 3964(R)/RK512
SIMATIC S7 MPI Direct
SIMATIC S7 Ethernet
SIMATIC S5 CPU Direct
SIMATIC S5 3964(R)
PROFIBUS DP Slave
GE Fanuc Automation
Series 90 Ethernet (SRTP)
Series 90-30/70 SNP
Series 90-30/70 SNP-X
Schneider Electric
Modbus Master (SIO or TCP)
Modbus Slave (SIO or TCP)
Modbus Plus
Uni-Telway
Modbus IDA
General Modbus RTU Master
(SIO)
General Modbus TCP Master
(Ethernet)
Control Technologies Corp.
CTC Binary Protocol (SIO)
Emerson Process Control
Emerson ROC Plus (Eth/SIO)
FANUC
Power Mate Series
FATEK Automation Corporation
FB Series SIO
Fuji Electric Corp.
MICREX-F Series SIO
MICREX-SX Series (Eth/SIO)
Temperature
Controllers
CHINO Corporation
Temp. Controller Modbus SIO
Fuji Electric Systems Co., Ltd.
Temp. Controller Modbus SIO
OMRON Corp.
Temp. Controller CompoWay/F
RKC Instrument
Temp. Controller MODBUS SIO
Temp. Controller SIO
Fieldbus Module
CAN in Automation
CANopen Slave
CC-Link Partner Association
CC-Link Intelligent Device
ODVA
DeviceNet Slave
EtherNet/IP Explicit messaging
PROFIBUS International
PROFIBUS DP Slave
Other Connections
Digital Electronics Corp.
Memory Link (Eth/SIO)
General Ethernet/SIO (via Script)
Vision Systems
Banner Engineering Corp.
PresencePlus Ethernet Cameras
COGNEX
Insight 5000 and Micro Ethernet
Cameras
Robot Controllers
GE Fanuc Automation
Series 90 Ethernet (SRTP)
Hyundai Heavy Industries
H14 Robot Driver
IAI Corporation
Robo Cylinder Modbus SIO
X-Sel Controller
Inverters
Fuji Electric Corp.
Inverter SIO
Hitachi IES Co., Ltd.
Inverter ASCII SIO
Inverter Modbus RTU
Mitsubishi Electric Corporation
FREQROL Inverter (SIO)
YASKAWA Electric Corp.
Inverter SIO
ETH
USB
Serial
Model
Type
Comments
Aimex Corp.
BR-530RS
Pen
OPT Electronics
OPT-6125-RS
Denso Co.
HC-36IITR
Requires P-200 for power; also requires KRS-423-XF1K connector cable (from Sanwa Supply)
HHP
IT3800LR-12
Linear imager
Requires cable 42203758-03 (IT3800LR-12 reader has been shown to work but is not fully tested)
Cognex
Dataman 7500
Any/All
Any
Printer
ASCII text
Aimex Corp.
BR-530UK
Pen
OPT Electronics
OPT-6125-USB
Denso Co.
HC-36TU-K
HHP
IT5800
Symbol
LS3408-FZ
Symbol
LS2800
Epson
Inkjet printer
Epson
Any
ECS/P24-J84(C) compatible
NEC
Any
PC-PR201-PL compatible
Any/All
Any
Any/All
Any
Printer
ASCII text
31
Operating Environment
GP-Viewer EX
GP-Pro EX
OS
CPU
Resolution
Memory
Hard Disk Space
Language
Software
Menu
Languages that
Hardware can Display
Other
Mouse (absolutely necessary), CD-ROM drive (necessary only for software installation)
and printer (supported by the OS above)
OS
CPU
Display Resolution
Memory
Hard Disk Space
Pass-Through
OS
Memory
Other
Memory
OS
OS
Transfer Tool
APL/PS
CPU
OS
Visit http://www.uvnc.com/
Other
GP-Pro EX (Ver. 2.0 or later) , RPA Keycode (EX-RPA (Sold separately) ), Ultra VNC Ver. 1.0.2
should be installed on the PCs on the server, LAN cable, HUB (Commercially available).
* Connect one server to one GP.
Web Server
OS
Supported Browser
Screen Resolution
OS
CPU
Memory
Hard Disk Space
Pro-Server EX
OS
CPU
Resolution
Memory
Hard Disk Space
Other Software
Printer
Network Adapter
Network Configuration
32
Other
512MB or greater
60MB or greater *Free space necessary for installation
Mouse (absolutely necessary), CD-ROM drive (necessary only for software installation)
Windows Media Player 9.0, Direct X9.0c
Movie files that can be converted with the movie converter are different depending on the PCs used for
conversion. Some codecs are equipped as standard in video/audio players such as Windows Media Player.
When installing the movie converter in an environment just after purchasing a PC, you can convert movie
files described above to SDX. For movie files that cannot be converted to SDX, you may be able to convert
these files by installing their codecs separately (*).
File format (Extension)
Video codec
Audio codec
AVI
Uncompressed (RGB)
Uncompressed (PCM)
AVI
DV-1
DV Audio
WMV
WMV9
WMA9
MPG
MPEG-1
MPEG-1 Layer-2
*In order to convert movie files, first, you need to install the codec of the movie file to be
converted on a PC for conversion. We have confirmed the conversion of the following movie files
to SDX on a PC with Ulead Video Studio 9 installed.
File format (Extension)
Video codec
Audio codec
AVI
DV-2
DV Audio
MPG
MPEG-2
MPEG-1 Layer-2
ASF
SD-Video (MPEG-4)
G.726
Note1) The environment recommended by the OS used, or a superior environment, is required for CPU/memory.
Note2) Partial restrictions available when using Windows Vista with Pro-Server EX. Check Website for details.
Rem
Acc ote P
ess
C
GP
V
EX iewe
r
Tra
n sf
er T
ool
Me
m
Loa ory
der
Pas
s Th
rou
gh
ver
Ser
erv
er
FTP
Function
We
bS
Data Management
Logged Data (sampling)
Recipe Data Update & Backup
Ordering Information
Description
Part Number
EX-ED-Vxx
Web Server
Included
FTP Server
Included
Transfer Tool
Included
Memory Loader
Included
Pass Through
Included
GP-Viewer EX
License for 1 HMI
EX-VIEWER-LICENSE
EX-VIEWER-LICENSE-10
EX-VIEWER-LICENSE-30
Remote PC Access
License for 1 HMI
EX-RPA
EX-RPA-10
EX-RPA-30
33
Pro-face Espaa
Pro-face Italia S.p.a.
International Pro-face
Pro-face Head Office
Pro-face Branch Office
Distributor or
Sales Representative
34
http://www.profaceamerica.com
* For details on available support content, please contact the relevant Pro-face office.
35
Pro-face America
1050 Highland Drive, Suite D
Ann Arbor, MI 48108 USA
Tel: 734-477-0600 or
Toll Free: 800-289-9266
Fax: 734-864-7347
http://www.profaceamerica.com
BR-Software Solutions12(A)
2012 Pro-face America. All rights reserved. All trademarks are the property of their respective owners.
Data subject to change without notice. Consult Pro-face data sheets for current product information.