Documente Academic
Documente Profesional
Documente Cultură
208/230 V, 60 Hz Models
HDC18
P1323013M
HDC18SD
P1323014M
HDC21
P1323016M
CRC18T2OG
CRC21T2RL
P1323015M
P1323017M
Due to possibility of personal injury or property damage, always contact an authorized technician for servicing or
repair of this unit.
Refer to Service Manual RS2240002 for installation, operating, testing, troubleshooting, and disassembly
instruction.
Refer to Parts Manuals RP2230003 and RP2230004 for part number information.
CAUTION
WARNING
To avoid the risk of electrical shock, personal injury, or death, disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.
Models
Power Source
Voltage AC
Amperage (Single Unit)
Frequency
Single Phase, 3 wire grounded
Receptacle
Plug
Power Output
Nominal microwave energy (IEC705)
Operating Frequency
Power Consumption
Cook Condition Microwave
Dimensions
Cabinet
Width
Height
Depth
Oven Interior
Width
Height
Depth
Weight
Crated
Uncrated
July 2006
2006 Maytag Services
HDC18
HDC18SD
CRC18T2OG
HDC21
CRC21T2RL
230/208 VAC
20 A
60 Hz
X
6-20R
6-20P
230/208 VAC
20 A
60 Hz
X
6-20R
6-20P
1800 Watts
2450 MHz
2100 Watts
2450 MHz
2850 Watts
3450 Watts
16 5/8
13 3/16
21 9/16
16 5/8
13 3/16
21 9/16
13
6 7/8
12
13
6 7/8
12
74 lbs.
68 lbs.
74 lbs.
68 lbs.
16027355
Replaces RT2240005 Rev. 1
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.
Illustration
MT2
MT1
GA TE
Component
Thermal Cutout
Test
Results
Disconnect all wires from TCO.
Measure resistance across terminals.
B5795302................... Cavity Thermal Fuse...................................... Open at 219 F (104 C).
B5684121................... Magnetron TCO ............................................. Open at 280 F (138 C) and
closed at 180 F (82 C).
Infinite resistance should be measured
Diode Assembly
Discharge Capacitors
in one direction and 50K or more in
the opposite direction.
Remove diode lead from capacitor and
connect ohmmeter.
NOTE: Analog meter must contain a
battery of 6 volts minimum.
Reverse leads for second test.
Triac
Disconnect wires to triac.
Caution - Do not operate oven with
wire to terminal MT2 removed.
Measure resistance from:
MT1 to MT2 ................................................... Infinite.
MT1 to Gate................................................... Approximately 40 or more.
MT2 to Gate................................................... Infinite.
All terminals to ground ................................... Infinite.
Capacitor
Discharge Capacitors
CRC18T2OG,
HDC18, HDC18SD
10366919
HDC21,
CRC21T2RL
10366917
Snubber Assembly
Discharge Capacitors
CRC18T2OG,
HDC18, HDC18SD
D7831007
HDC21,
CRC21T2RL
10489404
R0150197 top
R9900668 bottom
Stirrer motor
Blower Motor
16027355
Replaces RT2240005 Rev. 1
July 2006
2006 Maytag Services
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.
Illustration
Component
Auto Transformer
230
208
COM
208
120
230
120
0
1
3
Transformer
#1
#3
#2
#5
#6
#7
#8
#4
1.0 F
-300 MA
-300 MA
1.0 F
Terminal 1- 230 V
Terminal 2- Common
Terminal 3-208 V
Test
Discharge Capacitors
Remove all wires from terminals.
Measure resistance from:
230 to 0..........................................................
208 to 0..........................................................
120 to 0..........................................................
Discharge Capacitors
Remove all wires from terminals.
Measure resistance from:
Terminal 1 to 2 ...............................................
Terminal 1 to 3 ...............................................
Terminal 5 to 6 ...............................................
Terminal 7 to 8 ...............................................
Terminal 4 to Ground screw on transformer ...
Terminal 4 to any other terminal.....................
Violet
3
1
Gray
Interlock switch
assembly
Secondary
2
Red
Door Closed
Primary / Logic C
Touch Panel
Assembly
NO
Monitor
NC
Secondary
NO
CRC18T2OG,
CRC21T2RL
R9900580
July 2006
1.0 .
Less than 1 .
Less than 1 .
Less than 1 .
30 .
Infinite resistance. If not, replace
transformer.
Mo nitor
Wire Harness
42.4 .
38.6 .
21.5 .
Primary /
Logic
HDC18, HDC18SD,
HDC21
R9900111
Results
Pad
1
2
3
4
5
6
7
8
9
0
Start
Stop/Reset
Power Level
X2
Time Entry
Pins
8 & 10
7 & 10
6 & 10
5 & 10
4 & 10
3 & 10
8&9
7&9
6&9
5&9
4&9
4&8
5&8
6&8
7&8
Measurement
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
Continuity
16027355
Replaces RT2240005 Rev. 1
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.
Illustration
CRC18T2OG
12495209Q
Component
Controller board
P2
CRC21T2RL
12495210Q
10
10
HDC18, HDC18SD,
HDC21
12470109
P1
A B C DE
F G
P2
Pin #1
P1 connector used
for touch panel
ribbon
P1
Pin #1
Test
All Models
Line voltage to control board
P2 connector
Pin 1Pin 3..............................................
Output drive voltage to triac
Triac terminals............................................
GateT1 ..................................................
208 VAC line voltage
Fan relay (controls blower motor, antenna
motor(s), and oven light)
Control board..............................................
Terminals CD ........................................
Line voltage sensing relay (automatically
switches for 208 or 230 VAC operation)
Control board..............................................
Terminals FG ........................................
230 VAC line voltage
Fan relay (controls blower motor, antenna
motor(s), and oven light)
Control board..............................................
Terminals CE ........................................
Line voltage sensing relay (automatically
switches for 208 or 230 VAC operation)
Control board..............................................
Terminals FH ........................................
Results
Corrective Action
Replace HV/LV Board
Replace HV/LV Board
Replace HV/LV Board
Replace Touch Panel
Replace HV/LV Board
Conditions
Initial Power Up Condition: Apply power to oven with door closed.
Idle Condition:
Standby Condition:
Cook Condition:
16027355
Replaces RT2240005 Rev. 1
July 2006
2006 Maytag Services
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.
(F)
THIRTY THREE (33) SECONDS run time chart for units more than 1550 Watts cooking power
Cooking
T
Cooking
T
Cooking
T
Cooking
Power Output
(F) Power Output
(C) Power Output
(C) Power Output
17
18
19
20
21
22
23
(F)
18
19
20
21
22
23
24
25
26
1319
1395
1472
1550
1627
1705
1782
24
25
26
27
28
29
1860
1937
2015
2092
2170
2247
11
11.5
12
12.5
13
13.5
1540
1610
1680
1750
1820
1890
14
14.5
15
15.5
16
1960
2030
2100
2170
2240
SIXTY-THREE (63) SECONDS run time chart for units less than 1550 Watts cooking power
Cooking
T
Cooking
T
Cooking
T
Cooking
Power Output
(F) Power Output
(C) Power Output
(C) Power Output
697
27
1046
10
700
16
1120
736
28
1085
11
770
17
1190
775
29
1124
12
840
18
1260
814
30
1162
13
910
19
1330
852
31
1201
14
980
20
1400
891
32
1240
15
1050
930
33
1279
969
34
1317
1007
35
1359
July 2006
2006 Maytag Services
16027355
Replaces RT2240005 Rev. 1
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.
Primary / Logic
Monitor
Secondary
12538801
! DANGER
HIGH VOLTAGE
16027355
Replaces RT2240005 Rev. 1
July 2006
2006 Maytag Services
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to oven and discharge capacitor
before servicing, unless testing requires power.
(Primary / Logic)
12538801
! DANGER
July 2006
2006 Maytag Services
HIGH VOLTAGE
7
16027355
Replaces RT2240005 Rev. 1