Product Training
Lube Oil
System
MAN Turbo AG
GF14
16-Jun-09
< 1 >
On / in GT
baseframe
Within enclosure
on the suctionside
z exception:
oil cooler
MAN Turbo AG
GF14
16-Jun-09
< 2 >
MAN Turbo AG
GF14
16-Jun-09
< 3 >
Warning
GF14
16-Jun-09
< 4 >
3 Oil demister
Instruments for
monitoring pressure,
level, temperature
MAN Turbo AG
GF14
16-Jun-09
< 5 >
Location
z integrated in the
GT baseframe
Function
z total volume
greater than the
permissible
volume of oil
charge
to permit the
oil to expand
during
operation,
to ensure
effective
degassing
MAN Turbo AG
GF14
3 Oil demister
16-Jun-09
< 6 >
MAN Turbo AG
GF14
16-Jun-09
< 7 >
Operation
z inside the tank
perforated sheets
to remove the air
trapped in the oil
arranged at oil
return line.
z baffle plates
welded inside
increase dwell
time of the
returned oil
z guarantee that
the total volume
of oil is used for
lubrication.
MAN Turbo AG
GF14
3 Oil demister
16-Jun-09
< 8 >
Operation
z manholes used for
inspecting or
cleaning
z filler nozzle
also to take oil
samples,
z nozzles for measuring
oil temperature and
oil pressure and for
checking the level,
z boreholes for
accommodating pumps.
z oil drain connection in
the lower part of the
tank.
MAN Turbo AG
GF14
16-Jun-09
< 9 >
Location
z electrical
heaters
installed
horizontally
in the GT
baseframe or
lube oil tank
Function
z heat oil to
required
minimum
temperature
before start
up
MAN Turbo AG
GF14
3 Oil demister
16-Jun-09
< 10 >
Main parts
z connection head with integrated
temperature controller and limiter,
z heating bundle with flange.
Operation
z to inspect the heating bundle for deposits,
heating bundle can be removed from the
TR = temperature controller
MAN Turbo AG
GF14
2 Temperature controller
4 Control terminal
16-Jun-09
< 11 >
Operation
z temperature controller in connection
head of the heater
to heat the oil to the start-up
temperature
z temperature limiter
to switchoff when at maximum
permissible oil temperature
TR = temperature controller
MAN Turbo AG
GF14
2 Temperature controller
4 Control terminal
16-Jun-09
< 12 >
Note
Do
TB = temperature limiter
TR = temperature controller
approx. 10 C
z eliminate the cause of the fault,
z re-activate limiter manually by pressing
limiter button
MAN Turbo AG
GF14
2 Temperature controller
4 Control terminal
16-Jun-09
< 13 >
Warning
MAN Turbo AG
GF14
16-Jun-09
< 14 >
Pumps
Main lube oil
Location
z mounted in the front region of
GT baseframe and feed the
oil through a suction pipe out
of the tank to the bearings.
Function
z displacement screw pumps
z feed oil through a suction
pipe out of the tank into the
supply line
MAN Turbo AG
GF14
16-Jun-09
< 15 >
Pumps
Main lube oil
Operation
z during various operating phases only
one pump is running
start-up,
shutdown,
load operation,
re-lubrication phase,
z pumps used alternately
with next start the previously not
MAN Turbo AG
GF14
16-Jun-09
< 16 >
Pumps
Main lube oil
If pressure drops
z second main lube oil pump is automatically activated
z originally operating pump is switched off
If AC supply fails
z emergency lube oil pump is switched on
z to guarantee oil supply during the subsequent automatic
shutdown process.
z load operation with emergency lube oil pump is not
possible.
Safety valve at each pump.
z if pressure too high,
z returns lube oil to lube oil tank to protect the pump.
MAN Turbo AG
GF14
16-Jun-09
< 17 >
Motors
Main lube oil pumps drive
Operation
z three-phase AC motors
z connected to pump via
elastic coupling
MAN Turbo AG
GF14
16-Jun-09
< 18 >
Pump
Emergency Lube oil supply
Location
z installed at the front baseframe
Function
z if main lube oil pumps or AC supply
fails
supplies oil through suction pipe
out of the tank and into supply line
protects the bearings against
damage
Operation
z displacement screw pump
z fed from a reliable electricity supply
z safety valve at the pump
if pressure is too high lube oil is
returned into lube oil tank
MAN Turbo AG
GF14
16-Jun-09
< 19 >
Motor
Emergency Lube oil pump drive
Operation
z connected to pump via an
elastic coupling.
MAN Turbo AG
GF14
16-Jun-09
< 20 >
Cooler
Location
z piping to the oil
cooler at front side
of baseframe
Function
z installed upstream
of the dual oil filter
z cools the oil
supplied via the
temperature control
valve
Main components
z heat exchanger and
z AC fans
fans individually
switched on
MAN Turbo AG
GF14
16-Jun-09
< 21 >
Motors
Oil cooler fans drive
Location
z outside sound enclosure
MAN Turbo AG
GF14
16-Jun-09
< 22 >
Location
z behind the temperature
control valve in the supply
line
z in the front area of the GT
baseframe
z access through door in the
acoustic enclosure
MAN Turbo AG
GF14
16-Jun-09
< 23 >
Function
z guarantees that only
filtered oil enters the
bearing regions
z dual oil filter is installed
In order to change the
filter
z differential pressure
monitored by
differential pressure
manometer
differential pressure
sensor.
MAN Turbo AG
GF14
2 Manometer
4 Filter cartridge
6 Contaminated oil discharge
16-Jun-09
< 24 >
Operation
z without interrupting through
change-over valve
z filter change during operation
vent valve at each filter
and
drainage valve.
pressure equalization
after filter change
MAN Turbo AG
GF14
2 Manometer
4 Filter cartridge
6 Contaminated oil discharge
16-Jun-09
< 25 >
Oil demister
Location
z within the GT
enclosure
z on the left-hand
side in the area
of the power
turbine
Main components
z side-channel fan
z filter casing
z filter cartridge.
MAN Turbo AG
GF14
16-Jun-09
< 26 >
Oil demister
Function
Oil demister
1 Motor
4 O-ring
7 Drain
MAN Turbo AG
GF14
16-Jun-09
< 27 >
Oil demister
Function
Warning
Do not
z change to prevent switch-off of the
installation
z as a result of a non-permissible tank
vacuum.
Oil demister
1 Motor
4 O-ring
7 Drain
MAN Turbo AG
GF14
16-Jun-09
< 28 >
Motor
Oil demister fan drive
Location
z installed on filter
housing cover of
demister
Operation
z AC motor for
side-channel
fan.
MAN Turbo AG
GF14
3 Oil demister
16-Jun-09
< 29 >
Location
z outside the enclosure
z in supply line in front of
oil cooler
Function
z the 3-way valve
T e m p e r a t u r e c o n t r o l v a lv e
A to o il filte r
1 C o n tr o lle r e le m e n t
MAN Turbo AG
GF14
B fr o m p u m p
2 C o n tr o lle r e le m e n t
C v o m K h le r
16-Jun-09
< 30 >
Operation
z rapid heating
during the first
minutes of operation
through cooler
bypass function.
z constant oil temperature
during operation
by conveying oil
through cooler
T e m p e r a t u r e c o n t r o l v a lv e
A to o il filte r
1 C o n tr o lle r e le m e n t
MAN Turbo AG
GF14
B fr o m p u m p
2 C o n tr o lle r e le m e n t
C v o m K h le r
16-Jun-09
< 31 >
Operation principle
z with wax expansion
elements and
z exhibits a proportional
control action.
z temperature range of
control element is
selected in accordance
with ambient
temperature in the place
of installation
T e m p e r a t u r e c o n t r o l v a lv e
A to o il filte r
1 C o n tr o lle r e le m e n t
MAN Turbo AG
GF14
B fr o m p u m p
2 C o n tr o lle r e le m e n t
C v o m K h le r
16-Jun-09
< 32 >
Operation details
z if oil temperature is
above temperature
range
connection marked
B fully is closed
connection marked
C is opened
total oil volume
passes through oil
cooler.
T e m p e r a t u r e c o n t r o l v a lv e
A to o il filte r
1 C o n tr o lle r e le m e n t
MAN Turbo AG
GF14
B fr o m p u m p
2 C o n tr o lle r e le m e n t
C v o m K h le r
16-Jun-09
< 33 >
Operation details
z if oil temperature is
below temperature
range
connection marked
C is fully opened
connection marked
B is closed.
total oil volume does
not pass through oil
cooler,
but directly to dual
oil filter
T e m p e r a t u r e c o n t r o l v a lv e
A to o il filte r
1 C o n tr o lle r e le m e n t
MAN Turbo AG
GF14
B fr o m p u m p
2 C o n tr o lle r e le m e n t
C v o m K h le r
16-Jun-09
< 34 >
Operation details
z if oil temperature is
within temperature range
connection marked
C opens to the
same extent as
connection B
closes
uncooled oil is mixed
with the cooled oil
T e m p e r a t u r e c o n t r o l v a lv e
A to o il filte r
1 C o n tr o lle r e le m e n t
MAN Turbo AG
GF14
B fr o m p u m p
2 C o n tr o lle r e le m e n t
C v o m K h le r
16-Jun-09
< 35 >
GF14
16-Jun-09
< 36 >
MAN Turbo AG
GF14
16-Jun-09
< 37 >
MAN Turbo AG
GF14
16-Jun-09
< 38 >
MAN Turbo AG
GF14
16-Jun-09
< 39 >
Monitoring instruments
z manometer,
z pressure switch and
z pressure sensor
Housed at the front
right-hand side of a
frame within enclosure.
Manometers can be read
off through the glass
panel of the enclosure
door
MAN Turbo AG
GF14
16-Jun-09
< 40 >