Sunteți pe pagina 1din 2

represented by:

measurIT technologies

ST75V Mass Flow Meter


with Vortab Flow Conditioners ST75V Specifications
FEMALE NPT 3.28 4.50 3.82
[83] [114] 1/2 INCH
[97]
NPT Port, 2X

3.56
[90]
Dim B
3/4 INCH TO 1/2 INCH Max
NPT REDUCER
Local or Integral
1/4 INCH NPT w/o Display Enclosure
Dim A PROCESS CONNECTION

Dim C

Dim D

1. Dimensions are in INCHES; brackets [ ] are in MILIMETERS.

Female NPT Configuration


Vortab Flow Conditioners Configuration DIM A DIM B DIM C DIM D
Pipe Size Top to flow CL Flow CL to Bottom VMR Length
ST75V-XXXCE 1/4” 5.50 [140] 0.38 [9,5] 5.00 [127]
ST75V-XXXEE 1/2” 5.69 [144,5] 0.57 [14] 7.50 [190,5]
ST75V-XXXFE 3/4” 6.45 [164] 0.69 [17,5] 9.00 [229]
ST75V-XXXGE 1” 6.44 [163,5] 0.88 [22] 9.00 [229]
Precision Mass Flow Meters Compatible with Line ST75V-XXXHE 1 1/2” 6.42 [163] 1.25 [32] 13.50 [343]
Sizes from 1/4” to 2” [ 6 to 51mm] for Industrial ST75V-XXXJE 2” 6.43 [163] 1.50 [38] 18.00 [457]

and Commercial Process Gases


MALE NPT
3.28 4.50 3.82
For intallations with inadequate straight-run or obstructed flows that prevent a [83] [114]
1/2 INCH
NPT Port, 2X
[97]

fully developed profile for accurate flow measurement with the standard ST75,
the Model ST75”V” provides the solution. FCI’s Mode ST75V includes all of the 3.56
features and functionality of the ST75 plus built-in Vortab flow conditioning. Dim B
[90]
3/4 INCH TO 1/2 INCH Max
NPT REDUCER
Local or Integral
Vortab flow conditioners are the flow conditioning technology proven and 1/4 INCH NPT
PROCESS CONNECTION w/o Display Enclosure
recommended by flow measurement experts to eliminate both swirl and velocity Dim A

profile distortions to ensure accurate flow measurement. Vortab flow conditioners Dim C

also are the lowest pressure loss solution of all flow conditioning techniques. FCI Dim D

is the exclusive provider of Vortab flow conditioners for use with thermal mass 1. Dimensions are in INCHES; brackets [ ]are in MILIMETERS.
flow meters such as the ST75V.
Male NPT Configuration
In applications with limited space for pipe straight-run or when obstructors such Configuration DIM A DIM B DIM C DIM D
as valves, bends, couplings or any other disturber which alters the flow profile are Pipe Size Top to flow CL Flow CL to Bottom Tee Length
present, the ST75V is the solution to ensure the highest accuracy and repeatability. ST75V-XXXCN 1/4” 5.50 [140] 0.38 [9,5] 5.00 [127]
ST75V-XXXEN 1/2” 5.69 [144,5] 0.42 [10,6] 7.50 [190,5]
ST75V-XXXFN 3/4” 6.45 [164] 0.51 [13] 9.00 [229]
ST75V-XXXGN 1” 6.44 [163,5] 0.65 [16,5] 9.00 [229]
ST75V Specifications ST75V-XXXHN 1 1/2” 6.42 [163] 0.95 [24] 13.50 [343]
Process Connections: Choice of Female NPT, Male NPT, ANSI flanges, DIN flanges ST75V-XXXJN 2” 6.43 [163] 1.19 [30] 18.00 [457]
Media Compatibility: Air, compressed air, nitrogen, oxygen, argon, CO2, ozone,
other inert gases, natural gas and other hydrocarbon gases, hydrogen. FLANGED
Accuracy: ±1% of reading, ±0.5% full scale 3.28
[83]
4.50
[114]
1/2 INCH 3.82
[97]
NPT Port, 2X
Repeatability: ±0.5%
Temperature Compensation:
3.56
Standard: 40° to 100°F [4°to 38°C] [90]
Dim B
Optional: 0° to 250°F [ -18° to 121°C] 3/4 INCH TO 1/2 INCH Max
NPT REDUCER
Turndown Ratio: 10:1 to 100:1 1/4 INCH NPT Local or Integral
w/o Display Enclosure
Agency Approvals: Dim A
PROCESS CONNECTION

FM/CSA: Class I, Div. 1, Groups B, C and D.


Class I, Div. 2, Groups A, B, C and D, T4. Dim C

ATEX: II 3G EEx nA II T6; II 3D T65 C (DC power only)


Element Materials of Construction: All-welded 316 Stainless Steel with Dim D

1. Dimensions are in INCHES; brackets [ ]are in MILIMETERS.


Hastelloy-C thermowells. 2. Flanges are 150# Class.
Maximum Operating Pressure: 240 psi [ 16.5 bar(g)]
Input Power: Flanged Configuration
DC: 18 to 36 Vdc Configuration DIM A DIM B DIM C DIM D
Pipe Size Top to flow CL Flow CL to Bottom Tee Length
AC: 85 to 265 Vac
ST75V-XXXCF 1/4” n/a n/a n/a
Operating Temperature Range: 0° to 140°F [ -18° to 60°C]
ST75V-XXXEF 1/2” 6.9 [144,5] 1.75 [45] 7.50 [190,5]
Digital Display (Optional): 4-digit (9999 counts) LCD; 0.45” H [11.4 mm]
ST75V-XXXFF 3/4” 6.45 [164] 1.94 [49] 9.00 [229]
characters.
ST75V-XXXGF 1” 6.44 [163,5] 2.12 [54] 9.00 [229]
ST75V-XXXHF 1 1/2” 6.42 [163] 2.50 [64] 13.50 [343]
ST75V-XXXJF 2” 6.43 [163] 3.00 [76] 18.00 [457]

MeasurIT Technologies Ltd.


Craan, Craanford, email: info@measurIT.com Phone: +353 (0) 53 942 8962
Gorey, Co. Wexford, Ireland www.measurIT.com Fax: +353 (0) 53 942 8963
represented by:
measurIT technologies

Block No. 1 2 3 4 5 6 7 8 9 10
Ordering Guide MODEL ST75V-
Code Base Unit, Enclosure Style (Block No. 1) Code Gas Medium and System Calibration** (Block No. 8)
(Enclosures: all aluminum, NEMA 4X/IP67 rated, epoxy coated) B Air
1 Blind, Integral Transmitter, w/ two 1/2" FNPT cable entries C Air Equivalence (Oxygen, Chlorine, Ammonia, etc.)
2 Integral Transmitter with Local Digital Display, w/ two 1/2" FNPT cable entries E Nitrogen, Helium, Argon, CO2, Compressed Air
Remote Transmitter w/ two 1/2" FNPT cable entries and w/Digital Display. F Hydrocarbons (e.g. Natural Gas, Ethane, Methane, Propane, Ethylene, Propylene, Mixed)
3 (specify cable length in block 10)
G Hydrogen or hydrogen mixture
A Blind, Integral Transmitter, w/ two M20x1.5 cable entries
H Air, Compressed Air
B Integral Transmitter with Local Digital Display, w/ two M20x1.5 cable entries
J Air Equivalence (e.g. Oxygen, Chlorine, Ammonia, etc.)
C Remote Transmitter w/ two M20x1.5 cable entries and w/Digital Display.
(specify cable length in block 10) K Nitrogen, Argon

Code Pipe Installation-Flow Direction (Block No. 2) L CO2, Ethylene, Ethane


A Horizontal pipe w/flow right-to-left or vertical pipe w/flow up M Propane, Propylene
B Horizontal pipe w/flow left-to-right or vertical pipe w/flow down N Butane, Pentane
Code Power Supply (Block No. 3) P Methane, Helium, Natural Gas
1 DC; 18 - 36V R Hydrogen
2 AC; 85 - 265V, 50/60Hz Code Calibration***
Code Line Size (Block No. 4) Q High Accuracy 1% Calibration and Standard Conditions +40 to 100°F [+4 to 38°C] w/VORTAB
C 1/4" (Available only with NPT, block 5 must be code E or N.) High Accuracy 1% Calibration and Extended Temperature Compensation 0 to 250°F
T
E 1/2" [-18 to 121°C] w/ VORTAB
F 3/4" W Other, Agency Approved Customer Specified
G 1" Code Interconnecting Cable Length for Remote Configurations**** (Block No. 10)
H 1 1/2" 0 Not required (specify with integral configuations)
J 2" A 10 feet [3 meters]

Code Process Connection Type (Block No. 5) B 25 feet [7.6 meters]

E Female NPT C 50 feet [15 meters]


W Custom length. [Cannot exceed 50 feet (15 meters)]
N Male NPT
F Flanged, #150 CLASS
Other, Agency Approved Customer Specified Example: ST75V-2A2GF1GFM0 = Model ST75V flow meter with Vortab flow conditioners with local digital
W (if selected, block nr. 6 and 7 which follow must also be code WW only) display, AC powered, right-to-left flow for installation in 1" line, with 1" ANSI flanged process
connections for measuring natural gas at 1% accuracy under standard temperature conditions.
Code Process Connection Size, Material, Rating, Finish Details (Block No. 6 and 7)
Q0 1/4" NPT (must be selected if block 4 is code C) **: Must use FCI's AVAL program to determine letter code. AVAL is a custom flowmeter optimizer program
H0 1/2" NPT which considers gas medium, flow range, pipe size and other conditions to determine best calibration and
supplies FCI letter code to be used here. AVAL is available on-line at www.fluidcomponents.com or consult
T0 3/4" NPT
local FCI representative/distributor.
10 1" NPT
B0 1 1/2" NPT ***: Calibration accuracy is ±% of reading, ±0.5% of full scale.

20 2" NPT ****: Fixed cable length with instrument calibrated together as a matched set.
Cable may be coiled but not cut.
HG 1/2" ANSI flanged 150 lb RF ANSI 16.5, 316L stainless steel
TG 3/4" ANSI flanged 150 lb RF ANSI 16.5, 316L stainless steel
1G 1" ANSI flanged 150 lb RF ANSI 16.5, 316L stainless steel
BG 1 1/2" ANSI flanged 150 lb RF ANSI 16.5, 316L stainless steel
2G 2" ANSI flanged 150 lb RF ANSI 16.5, 316L stainless steel
D2 DN15 DIN flanged PN16, Form C per DIN2526 or Form B1 per DIN EN1092-1 in 316L ss
E2 DN25 DIN flanged PN16, Form C per DIN2526 or Form B1 per DIN EN1092-1 in 316L ss
G2 DN40 DIN flanged PN16, Form C per DIN2526 or Form B1 per DIN EN1092-1 in 316L ss
J2 DN50 DIN flanged PN16, Form C per DIN2526 or Form B1 per DIN EN1092-1 in 316L ss
WW Other, Agency Approved Customer Specified

Options and Accessories


Part Number Description Part Number Description
019819-01 Software Interface Package for PDA/PalmOS DM10-KIT1 Panel Mount Kit for DM10
020802-01 PDA, Palm model Tungsten E2 DM10-KIT2 2 inch (52 mm) Pipe Mount Kit for DM10 (Stainless Steel)
FC88 Portable Hand-held Communicator DM15 Digital Display/Readout, LED 115/230 Vac powered
014108-02 PC Interface Communications Kit, For RS232 serial port connection DM15-ALM Same as DM-15 with user programmable alarm limit, relay output
DM10-N Digital Display/Readout, LCD, 4-20mA loop powered DM20 Digital Display Readout, 8-digit LCD Pulse totalizer/counter
DM10-FC DM10 with FM and CSA approvals

MeasurIT Technologies Ltd.


Craan, Craanford, email: info@measurIT.com Phone: +353 (0) 53 942 8962
Gorey, Co. Wexford, Ireland www.measurIT.com Fax: +353 (0) 53 942 8963

S-ar putea să vă placă și