Wiring Guide
Issue 16
21958 Honeywell Issue 16_11394 Honeywell Issue 14 26/04/2011 09:04 Page IFC1
Contents
Section
Title
Introduction
Contact
Page
1
2
Wiring plans
3
4-5
6-7
8-9
10 - 11
12
13
14
15
16
17
18
19
20 - 21
22
23
Fault finding
Wired
Wired
Wired
Wired
24 - 25
26 - 27
28 - 29
30 - 31
Product selection
Energy saving
Product selection
32 - 33
34 - 37
Further information
Website
Training
38
39
Sundial
Sundial
Sundial
Sundial
Y Plan
S Plan and S Plan Plus
C Plan
W Plan
Introduction
Domestic energy consumption
60% Heating
3%
3%
3%
3%
2%
2%
Lighting
Cooking
Consumer electronics
Cold appliances
Other
Wet appliances
Source : BERR
2009 Honeywell International Inc. All rights reserved.
A huge amount of energy is used to heat homes. Much of it is either wasted or used inefficiently.
Heating controls help to reduce waste reduce demand and use fuel more sparingly.
Honeywell has been manufacturing heating controls for over 100 years and is the UK leader for
quality, efficiency and reliability.
This book contains wiring advice to assist with installing Honeywell heating controls in a variety of
systems. Always try to upgrade a system to the best efficiency. This would normally be a fully
pumped system with a high efficiency boiler using S, Y or S Plan Plus controls.
All wiring should be carried out by a competent installer or electrician.
These wiring diagrams are for guidance only and at the time of printing represent the latest information available to
us from other manufacturers. Honeywell reserve the right at any time and without notice to change any product,
specification or any other information contained in this publication and cannot accept any responsibility for loss or
damage arising out of any errors that may inadvertently be contained herein.
Whilst Honeywell takes all reasonably practical steps to design and manufacture its products to comply with the
requirements of the Health and Safety at Work Act 1974, all products must be properly used and purchasers are
reminded that their obligations under the Act are to ensure that the installation and operation of such products at a
place of work should be safe and without risk to them.
Contact
Sales Enquiries
Tel: 01344 656172
Email: insidesales@honeywell.com
Installer Training
Tel: 01344 656352
Email: installer.training@honeywell.com
Web: www.honeywelluk.com (see Training page under Support Services menu)
Product Literature
Tel: 0800 521121
Email: literature@honeywell.com
Web: www.honeywelluk.com (see Downloads menu)
Technical Support
Tel: 08457 678999
Email: technical.support@honeywell.com
Web: www.honeywelluk.com (see FAQ section)
To help in dealing with your technical support enquiry efficiently (whether via phone or email) please
supply the part code, product name and date code. Please only call our technical support
number if you are an installer. End user support literature such as user guides and brochures is
available for download on our website.
All phone lines are open Monday to Thursday 9am to 5pm and Friday 9am to 4pm. Closed all bank
holidays.
Wiring plans
ALL WIRING MUST BE IN ACCORDANCE WITH IEE & BUILDING REGULATIONS AND IN
SOME CASES, NOTIFIABLE TO BUILDING CONTROL.
A list of programmers can be found on page 17. The room thermostat and programmer are for use
with fixed wiring only; the cylinder thermostat may be used with fixed wiring or flexible cable; the
motorised valves are supplied fitted with a one metre length of heat resistant cable.
A switch (having contact separation of at least 3mm in all poles) must be incorporated in the fixed
wiring as a means of disconnecting the mains supply.
The heating system must be appropriately fused for gas appliances. The diagrams refer only to 3
amp fuses for gas appliances throughout. Use a 5 amp fuse for oil where appropriate. The T6360B
room thermostat, L641A cylinder thermostat and Honeywell range of programmers are Class II
(double insulated) devices. Earth terminals, where provided, are for earth parking purposes only. All
earth conductors inside the programmer and room thermostat must be appropriately sleeved. The
zone valves are Class I devices and must be connected to a suitable earth.
Sundial S Plan
Brown
Blue
Grey
**
5
B
4
DT90E
Room
Thermostat
**
1
3
T6360B
Room
Thermostat
or
Orange
10
Green/
Yellow
4
CM901
CM907
Wireless
Thermostats
Available
or
V4043H
Heating
Valve
7
8
9
Brown
Blue
Grey
Orange
10
Not Used
Green/
Yellow
L641A
Cylinder
Thermostat
10
V4043H
Hot Water
Valve
10 Way junction
box. Honeywell
part no:
42002116-001
230 Volt
Mains Input
For list of central heating boilers to attach to this circuit - see page 16.
For list of programmers to attach to this circuit - see page 17.
When circuit is wired as above: Completed wiring will be as line drawing below.
Wired
NOTE:
GREY
BLUE
MOTOR
**
L641A
CYLINDER
STAT.
2 1 3
ORANGE
T6360B
ROOM STAT.
ORANGE
G/YELLOW
L N E
BROWN
230V
50Hz
3A RATED
V4043H
ZONE VALVE
HW
MOTOR
BROWN
G/YELLOW
GREY
V4043H
ZONE VALVE
HTG
BLUE
Wiring plans
If using a 6 wire 28mm or 1" BSP V4043H on either circuit, the white wire is not needed and must
be made electrically safe.
Pump overrun
1
7
10
10
N L
N EL
PUMP
SL
PL
L
E
N
BOILER
N EL
ST9400A/C
HW HTG
PUMP
L
E
N
BOILER
Sundial S Plan
Wireless room thermostat
BLUE
230V
50Hz
3A RATED
V4043H
ZONE VALVE
HW
BLUE
MOTOR
BROWN
G/YELLOW
GREY
GREY
V4043H
ZONE VALVE
HTG
MOTOR
L641A
L
N A B
CYLINDER
STAT.
ORANGE
RECEIVER
BDR91
BROWN
L N E
ORANGE
G/YELLOW
Pump overrun
1
7
10
10
N L
N EL
DT92E
WIRELESS ROOM
THERMOSTAT
SL
PL
L
E
N
N EL
PUMP
PUMP
HW HTG
ST9400A/C
L
E
N
BOILER
BOILER
L641A
CYLINDER
STAT.
ORANGE
G/YELLOW
ORANGE
L N E
MOTOR
BROWN
G/YELLOW
230V
50Hz
3A RATED
MOTOR
BROWN
GREY
V4043H
ZONE VALVE
HW
BLUE
GREY
DT92E
WIRELESS ROOM
THERMOSTAT
BLUE
LINK
Pump overrun
HEATING
R
HOT WATE
EXTRA
HOUR
10
OVERRIDE
EXTRA
N EL
PUMP
10
HOUR
OVERRIDE
SL
PL
L
E
N
BOILER
CONT
ONCE
AUTO
OFF
CONT
ONCE
AUTO
OFF
ST9420
PROGRAMMER
L
N
E
3
4
N EL
PUMP
L
E
N
BOILER
Wiring plans
NOTE:
**
5
B
4
DT90E
Room
Thermostat
or
** 4
Brown
Blue
Grey
Orange
10
Green/
Yellow
T6360B
Room
Thermostat
10 Way junction
box. Honeywell
part no:
42002116-001
V4043H
Heating
Valve 1
5
6
7
8
9
Brown
Blue
Grey
6
Not
Used
8
2
L641A
Cylinder
Thermostat
Orange
Blue
Grey
B
1
Orange
10
Green/
Yellow
Brown
7
CM901
CM907
10
10
Green/
Yellow
Wireless
Thermostats
Available
V4043H
Hot Water
Valve
V4043H
Heating
Valve 2
230 Volt
Mains Input
For list of central heating boilers to attach to this circuit - see page 16.
For list of programmers to attach to this circuit - see page 17.
When circuit is wired as above: Completed wiring will be as line drawing below.
Wired
V4043H
ZONE VALVE
HTG1
BLUE
230V
50Hz
3A RATED
CM900 SERIES
PROGRAMMABLE
STAT.
L641A
T6360B
ROOM STAT.
**
CYLINDER
STAT.
2 1 3
1
ORANGE
L N E
10
10
N L
NEL
N EL
PUMP
SL
PL
L
E
N
BOILER
ST9400A/C
PUMP
HW HTG
L
E
N
BOILER
ORANGE
G/YELLOW
G/YELLOW
BLUE
MOTOR
Pump overrun
7
V4043H
ZONE VALVE
HTG2
MOTOR
ORANGE
BLUE
MOTOR
BROWN
G/YELLOW
V4043H
ZONE VALVE
HW
BROWN
BROWN
NOTE:
GREY
GREY
GREY
Wiring plans
If using a 6 wire 28mm or 1" BSP V4043H on either circuit, the white wire is not needed and must
be made electrically safe.
BLUE
G/YELLOW
CM900 SERIES
PROGRAMMABLE
STAT.
L641A
RECEIVER
BDR91
CYLINDER
STAT.
L
N A B
ORANGE
L N E
NEL
PUMP
HW HTG
10
L
E
N
BOILER
Pump overrun
10
N L
DT92E
WIRELESS ROOM
THERMOSTAT
ORANGE
BROWN
G/YELLOW
BLUE
MOTOR
230V
50Hz
3A RATED
ST9400A/C
V4043H
ZONE VALVE
HTG2
MOTOR
ORANGE
BLUE
MOTOR
BROWN
G/YELLOW
V4043H
ZONE VALVE
HW
BROWN
GREY
GREY
GREY
1. It is recommended that
the 10 way junction box
should be used to ensure
first time, fault free wiring.
N EL
PUMP
SL
PL
L
E
N
BOILER
Wiring plans
NOTE:
Sundial Y Plan
Fully Pumped System only
Wiring plans
A
5
**
or
230 Volt
Mains Input
T6360B
Room
Thermostat
5
B
DT90E
Room
Thermostat
**
or
Wireless
Thermostats
Available
3
5
6
White
Blue
Grey
Orange
Green/
Yellow
CM901
CM907
L641A
Cylinder
Thermostat
7
8
9
10
10 Way junction
box. Honeywell
part no:
42002116-001
V4073A
Mid.Pos.
Valve
For list of central heating boilers to attach to this circuit - see page 16.
For list of programmers to attach to this circuit - see page 17.
When circuit is wired as above: Completed wiring will be as line drawing below.
Wired
ORANGE
WHITE
230V
50Hz
3A RATED
GREY
V4073A
G/YELLOW
BLUE
NOTE:
L641A
CYLINDER
STAT.
**
L N E
T6360B
ROOM STAT.
2 1 3
MID POSITION
ZONE VALVE
C 2
10
Pump overrun
C
10
ST9400A/C
HW OFF
HW ON
HTG
LINK 8 TO 10
L
E
N
N L
N EL
PUMP
BOILER
SL
PL
L
E
N
BOILER
NEL
PUMP
Sundial Y Plan
Wireless room thermostat
L641A
L N E
CYLINDER
STAT.
RECEIVER
BDR91
L
N A B
DT92E
WIRELESS ROOM
THERMOSTAT
1
MID POSITION
ZONE VALVE
ORANGE
GREY
WHITE
230V
50Hz
3A RATED
V4073A
G/YELLOW
BLUE
Wiring plans
NOTE:
C 2
10
Pump overrun
LINK 8 TO 10
10
ST9400A/C
HW OFF
HW ON
HTG
L
E
N
N L
BOILER
SL
PL
L
E
N
N EL
PUMP
NEL
PUMP
BOILER
ORANGE
WHITE
230V
50Hz
3A RATED
GREY
V4073A
G/YELLOW
BLUE
L641A
MID POSITION
ZONE VALVE
CYLINDER
STAT.
L N E
1
C 2
DT92E
WIRELESS ROOM
THERMOSTAT
1
R
HOT WATE
EXTRA
10
HOUR
OVERRIDE
EXTRA
LINK 8 TO 10
HEATING
Pump overrun
N EL
PUMP
HOUR
OVERRIDE
CONT
ONCE
AUTO
OFF
CONT
ONCE
AUTO
OFF
10
SL
PL
L
E
N
BOILER
ST9420
PROGRAMMER
L
N
E
1
3
4
L
E
N
BOILER
NEL
PUMP
Sundial C Plan
A
5
**
**
1
3
or
T6360B
Room
Thermostat
230 Volt
Mains Input
or
5
B
DT90E
Room
Thermostat
2
CM901
CM907
3
4
Wireless
Thermostats
Available
1
6
Not Used
2
L641A
Cylinder
Thermostat
Brown
Blue
Grey
Orange
10
Green/
Yellow
White
10
Hot Water
Valve
10 Way junction
box. Honeywell
part no:
42002116-001
For list of central heating boilers to attach to this circuit - see page 16.
For list of programmers to attach to this circuit - see page 17.
When circuit is wired as above: Completed wiring will be as line drawing below.
Wired
NOTE:
V4043H
28mm
ZONE VALVE
BLUE
GREY
MOTOR
G/YELLOW
230V
50Hz
3A RATED
T6360B
ORANGE
L641A
L N E
CYLINDER
STAT.
ROOM STAT.
2 1 3
BROWN
Wiring plans
WHITE
LINK
1
10
N L
NEL
ST9400A/C
HW HTG
PUMP
L
E
N
BOILER
10
L
I
N
K
Sundial C Plan
Wireless room thermostat
V4043H
28mm
ZONE VALVE
BLUE
GREY
MOTOR
G/YELLOW
230V
50Hz
3A RATED
L
N A B
BROWN
CYLINDER
STAT.
RECEIVER
BDR91
DT92E
WIRELESS ROOM
THERMOSTAT
ORANGE
L641A
L N E
WHITE
LINK
1
10
N L
NEL
ST9400A/C
PUMP
HW HTG
L
E
N
BOILER
GREY
MOTOR
G/YELLOW
230V
50Hz
3A RATED
HEATING
R
EXTRA
CONT
ONCE
AUTO
OFF
CONT
ONCE
AUTO
OFF
10
NEL
HOUR
OVERRIDE
HOUR
OVERRIDE
WHITE
LINK
1
HOT WATE
BROWN
1
DT92E
WIRELESS ROOM
THERMOSTAT
EXTRA
ORANGE
L641A
CYLINDER
STAT.
L N E
ST9420
PROGRAMMER
L
N
E
3
4
PUMP
L
E
N
BOILER
11
Wiring plans
NOTE:
**
5
B
4
DT90E
Room
Thermostat
**
or
Blue
Grey
Orange
Green/
Yellow
T6360B
Room
Thermostat
Brown
5
B
CM901
CM907
Wireless
Thermostats
Available
or
V4043H
Heating
Valve
7
8
9
1
6
Not Used
2
L641A
Cylinder
Thermostat
Brown
Blue
Grey
Orange
10
Green/
Yellow
White
10
V4043H Hot
Water Valve
28mm or 1 BSP
10 Way junction
box. Honeywell
part no:
42002116-001
230 Volt
Mains Input
For list of central heating boilers to attach to this circuit - see page 16.
For list of programmers to attach to this circuit - see page 17.
When circuit is wired as above: Completed wiring will be as line drawing below.
Wired
V4043H
22mm
ZONE VALVE
HTG
NOTE:
G/YELLOW
T6360B
ROOM STAT.
2 1 3
L641A
CYLINDER
STAT.
ORANGE
L N E
MOTOR
G/YELLOW
ORANGE
230V
50Hz
3A RATED
MOTOR
BROWN
V4043H
28mm
ZONE VALVE
HW
BLUE
BROWN
GREY
GREY
BLUE
Wiring plans
WHITE
9
10
N L
NEL
ST9400A/C
HW HTG
PUMP
L
E
N
BOILER
12
Sundial W Plan
Fully Pumped System only (hot water priority)
A
**
DT90E
Room
Thermostat
** 4
T6360B
Room
Thermostat
or
B
1
CM901
CM907
Wireless
Thermostats
Available
or
3
4
230 Volt
Mains Input
5
6
7
8
Brown
Blue
10
Green/
Yellow
L641A
Cylinder
Thermostat
10 Way junction
box. Honeywell
part no:
42002116-001
V4044C
Diverter
Valve
For list of central heating boilers to attach to this circuit - see page 16.
For list of programmers to attach to this circuit - see page 17.
When circuit is wired as above: Completed wiring will be as line drawing below.
Wired
DIVERTER
VALVE
BROWN
230V
50Hz
3A RATED
V4044C
G/YELLOW
BLUE
NOTE:
L641A
CYLINDER
STAT.
L N E
T6360B
ROOM STAT.
2 1 3
C 2
Pump overrun
6
N EL
PUMP
10
SL
PL
L
E
N
10
N L
ST9400A/C
HW HTG
L
E
N
BOILER
BOILER
NEL
PUMP
13
Wiring plans
7
A
Sundial U Plan
Wiring plans
BROWN
N
LOUNGE
M100-BG MOTOR
BROWN
BLUE N
KITCHEN
M100-BG MOTOR
BROWN
BLUE N
BLUE
ROOM 2
DT90E
B A
GREY
MOTOR
ORANGE
V4043H
MANIFOLD 1
ZONE VALVE
N
N
ROOM 3
T6360B
2 1 3
N
L
MANIFOLD 1
PUMP
L
L
L
MASTER CONTROL
L BEDROOM 1
BROWN
N
BLUE
TYPICAL
SPST
RELAY
GREY
MOTOR
ORANGE
BDR91
BROWN
BLUE N
MOTOR
V4043H
MANIFOLD 2
ZONE VALVE
A
N
BED 2
M100-BG
BED 2
DT90E
BROWN
MOTOR
TYPICAL
SPST
RELAY
G/YELLOW
2 1 3
L641A
CYLINDER
STAT.
ORANGE
T6360B
ROOM STAT.
ORANGE
L N E
MANIFOLD 2
PUMP
MOTOR
BROWN
G/YELLOW
230V
50Hz
3A RATED
V4043H
ZONE VALVE
DHW
BLUE
GREY
BLUE
GREY
V4043H
ZONE VALVE
HTG
10
N L
NEL
HW HTG
TIME
CONTROLLER
PUMP
L
E
N
BOILER
Some earths
omitted for
clarity
14
Training
Installer Training courses
Wiring plans
Expand your knowledge of heating and water controls with expert training on our one day Installer
courses, all for 30.
Hands on wiring
Fault finding
Learn about the latest products
Energy conservation
Part L Building Regulations
15
Wireless controls
Zoning
Smartfit
Sundial plans
Frost protection
Control selection
Boiler Wiring
Wiring plans
Terminal Block
S Plan
S Plan Plus
Y Plan
C Plan
C Plan Plus
W Plan
BOILER
9
9
9
9
9
9
10
10
8
10
10
7
3
3
3
3
3
3
2
2
2
2
2
2
1
1
1
1
1
1
9
9
9
9
9
9
10
10
8
10
10
7
2
2
2
2
2
2
Terminal Block
3
3
3
3
3
3
PL
4
PL
PL
PL
PL
L
SL
SL
SL
SL
SL
SL
2
Sw
L
SL
Ls
SL
SL
1
1
L2
Sw
L
SL
Sw
L
Sw
L
E
E
E
E
E
E
E
E
E
N
N
N
N
N
N
N
N
N
L
L
L
L
L
L
E
E
E
E
3
4
E
E
N L L
N
N L
N L 7
2
L
2
L
N L3 L
N L L
E
E
N
N
L
L
L
L
N
N
N
N
N
N
N
N
N
E
E
E
E
E
E
E
E
E
N
N
E
E
8
N
N
N
N
E
E
E
E
E
L
L
N
N
E
E
L
L
L
Alpha CB24/28
Baxi Combi 130HE
Baxi Combi 80Eco
Baxi Combi 80 Maxflue
Baxi Combi Instant
Boulter Camray 5 (Oil)
Ferroli Arena
Ferroli Domina
Ferroli Optima
Glow-Worm Compact
Grant Combi MK11
Ideal C80/C95FF
Ideal Response
Potterton Combi 80
Potterton Flowsure+
Potterton Performa
Potterton Puma
Range Powermax
Valliant Turbomax
Worcester CDI
Worcester Greenstar
Worcester Highflow
Terminal Block
SYSTEM
BOILERS
PF SL E
PF SL E
L2 E
L2 E
SL E
PF SL E
Lr E
N
L
N L L
N L3
N L3
N PL
N L L
N L
L
L
N
N
N
N
E
E
E
E
S Plan
S Plan Plus
Y Plan
C Plan
C Plan plus
W Plan
2
2
2
2
1
1
1
1
1
1
1
1
5
7
5
7
E
E
E
E
E
E
E
E
E
E
4
E
E
E
E
E
E
E
E
E
E
E
N
N
N
N
N
N
N
N
N
N
2
N
N
N
N
N
2
N
N
N
N
N
L
L
L
L
L
L
L
L
L
L
1
L
L
L
L
L
1
L
L
L
L
L
1
3
1
1
1
4
1
4
4
1
13
Bk
R1
3
3
1
3
10
3
Ls
Ls
2
4
2
2
2
5
2
5
5
2
14
R
R2
4
4
2
4
9
4
Lr
Lr
L
10
1
L
Blk
PL Sw
L
E
E
4
E
E
E
N
3
2
N
N
N
L
L
L
L
L
L
L
L
N
N
N
N
N
N
BOILER
9
9
9
9
9
9
10
10
8
10
10
7
3
3
3
3
3
3
2
2
2
2
2
2
PUMP
1
1
1
1
1
1
9
9
9
9
9
9
10
10
8
10
10
7
2
2
2
2
2
2
3
3
3
3
3
3
CONDENSING
BOILER
Baxi 35/60 & 60/100
Baxi Solo 3 PFL
Boulter Bonus (Oil)
Ferroli Tempra
Glow-Worm Compact 60
Glow-Worm HXI
Grant Multipass (Oil)
Ideal Icos
Outdoor Modules 50/70
Valliant Ecotec
Valliant Thermocompact
OIL BOILERS
Boulter Bonus
Esse 60, 80, 100
Grant Multi Pass 50/70
Potterton Statesman
Rayburn 368K Range
Rayburn Heatranger
3
3
3
3
COMBI
BOILERS
Glow-Worm Energy 60
PL
Glow-Worm Micron FF
Glow-Worm Ultimate 60FF P
Glow-Worm Ultimate 70FF 7
Grant Euroflame 50/70
Grant Multipass 50/70
Ideal Istor
Potterton Kingfisher 50-100 PL
Baxi 100HE
Baxi Barcelona
Ideal Icos
Ideal Isar
Keston Celsius
Potterton Promax
Worcester Greenstar
COMBI
S Plan
S Plan Plus
Y Plan
W Plan
REGULAR
BOILER
Basic Boiler
Baxi 45/4 & 57/4
Baxi Bermuda
Baxi Inset 2-50/4e
Baxi Bermuda Inset 3
Baxi Boston 2
Baxi Solo 2 RS
Ferroli Roma 55FF
Ferroli Sigma
CM901
CM907
STAT
PUMP
E
E
E
E
E
E
16
SL E
PL SL E
E
SL E
Ls E
2 E
1 4
L2 E
1
4
4 E
4 E
N L
N L L
N L
N L
N Lp
N L
2
N L3
3 2
N L
N L
Programmer Wiring
HW OFF HW ON CH ON
Honeywell ST6200
Honeywell ST699B, ST799A, (Link L-5-8)
Honeywell ST7100
Glow-Worm Mastermind
Horstmann C21, C27, C121 & C127
Potterton Miniminder
Horstmann 425, 525, 527, H21, H27, H121, Tiara, (Link L-2-5)
Switchmaster Symphony
Sunvic DHP2201
10
10
17
Wiring plans
Programmer Interchange
Wiring plans
Valve Wiring
Replacement Wiring Guide for the old V4073A1005 to all new V4073A models
The old valve had 6 wires and a relay plugged into one end.
When replacing this old model with the newer model, wire the new valve colour for colour apart from
the Brown wire which is missing from the new valve.
ON SINGLE CHANNEL TIME SWITCHES
Omit Brown wire and reverse C & 1 on the cylinder thermostat.
ON DOUBLE CHANNEL PROGRAMMERS i.e. separate switching outputs for Heating and
Hot Water circuits.
Omit Brown wire and reverse C & 1 on the cylinder thermostat.
1. For programmers capable of selecting heating only: Run extra cable from the Grey wire on
the valve to the HOT WATER OFF terminal on the programmer.
2. For programmers NOT capable of selecting heating only: This extra cable is NOT required
and MUST NOT be included.
EXCEPT:
1. ON RANDALL 4033 PROGRAMMER
Remove wire that connects to cylinder thermostat 1 at JUNCTION BOX end and re-connect to
Orange wire connection of mid-position valve. Disconnect wire at Terminal 1 on programmer, isolate
and make safe. Add link in programmer back plate between Terminals 1 and 6.
NB. If the Randall 4033 has been used as a junction box, any wires going into terminal 1 should be
removed and re-connected into a spare terminal connector (not supplied by Honeywell).
2. ON SANGAMO 410 FORM 1 PROGRAMMER
Follow instructions for Randall 4033, except on programmer base plate, disconnect wire on Terminal
3 and add link between 3 and 6 on baseplate of Programmer.
MOTORISED VALVE INTERCHANGEABILITY GUIDE
E
CH
ON
HW
OFF
MODEL
V4073A
GY
BL
OR
WH
GR
ACL
679H340
GY
BL
OR
WH
GR
ACL
679B340
GY
BL
OR
WH
GR
Danfoss/Randall
DVM-3M
GY
BL
OR
WH
GR
Danfoss/Randall
HSA3
GY
BL
OR
BR
GR
Drayton
MODEL
HONEYWELL
Drayton Flowshare
No.
S/L
HW
ON
S/L Motor PL
V4043H
GY
BL
OR
BR
ACL
679H308-30L1
GY
BL
OR
BR
GR
ACL
679B308-30L1
GY
BL
BK
BR
WH
Danfoss/Randall
DVM-2C
GY
Danfoss/Randall
HP2A
HONEYWELL
GY
BL
OR
WH
GR
Grasslin/Tower
MP 22C
GY
BL
OR
WH
GR
Pegler/Sunvic
MAV322
GY
BL
OR
WH
GR
Potterton/Myson
GR
RE
WH
GR
Auto Z
GY
BL
OR
BR
GR
MV2-22C
GY
BL
OR
BR
GR
Sunvic V*203
GY
BL
(White wire - make electrically safe)
Connect Grey wire on V4043H to permanent live.
OR
YE
GR
Switchmaster
Potterton/Myson
PMV3
GY
BL
OR
BR
GR
Tower/Grasslin
Potterton/Myson
MSV322
BL
OR
WH
GR
Sopac
ZV20-EB
BL
RE
WH
GR
WH
WH
ADD LINK
GY = Green/Yellow
YE = Yellow
BK = Black
GR
BL
BR
YE
BR
GY
OR
YE
OR
ZV20-2-EB
Sopac
BL
OR
GR
BL
SZV 1212
GR
GY
OR
GR
BR
BR
SD1701
RE
BR
OR
BR
Pegler/Sunvic
RE
OR
BL
OR
Randall
GR
BL
BL
GY
OR
GR
WH
BL
GY
BL
WH
OR
GY
GR
GR
BL
OR
BL
GY
BR
BR
GY
BL
GY
MIDI
OR
OR
GY
GY
SDV2211
Danfoss Heatshare
BL
BL
HPA2
SD2701
Pegler/Sunvic
Switchmaster
ZAV222
GR
PMV43
Pegler/Sunvic
GY
No.
BL = Blue
BR = Brown
RE = Red
18
OR = Orange
WH = White
GR = Grey
Supplier
ACL-Drayton
ACL-Drayton
ACL-Drayton
ACL-Drayton
ACL-Drayton
ACL-Drayton
ACL-Drayton
ACL-Drayton
ACL-Drayton
ACL-Drayton
ACL-Drayton
ACL-Drayton
ACL-Drayton
ACL-Drayton
ACL-Drayton
Barlo
Boss Therm
Boss Therm
British Gas
British Gas
British Gas
Danfoss
Danfoss
Danfoss
Danfoss
Danfoss
Danfoss
Danfoss
Danfoss
Danfoss
Danfoss
Glowworm
Homexpert
Honeywell
Honeywell
Honeywell
Honeywell
Horstmann
Horstmann
Horstmann
Horstmann
Programmer
SM2
LP112
LP241
LP522
LP722
LP241Si
LP522Si
LP722Si
Tempus 3
Tempus 4
Tempus 6
Tempus 7
LS241
LS522
LS722
EPR1
RPF7
RP24
EMP1
EMP2
UP1
CP15
CP75
CP715
CP715Si
FP15
FP75
FP715
FP715Si
MP15
MP75
Mastermind
THR860S
ST6400A
ST6400C
ST9400A
ST9400C
Centaurplus C21
Centaurplus C27
Centaurplus C121
Centaurplus C127
Supplier
Iflow
Landis & Gyr
Landis & Gyr
Landis & Gyr
Landis & Gyr
Landis & Gyr
Landis & Gyr
Landis & Gyr
Landis & Gyr
Landis & Gyr
Landis & Gyr
Landis & Gyr
Landis & Gyr
Landis & Gyr
Landis & Gyr
Landis & Staefa
Landis & Staefa
Microgyr
Microgyr
Microgyr
Microgyr
Microgyr
Microgyr
Microgyr
Microgyr
Microgyr
Microgyr
Microgyr
Potterton
Potterton
Sankey
Siemens
Siemens
Sunvic
Thorn
Wickes
Wickes
Wickes
Wickes
Wickes
Programmer
Iflow PR
RWB40
RWB102
RWB200
RWB200cw
RWB252
RWB252cw
RWB270
RWB1
RWB Mk1
RWB2
RWB2 Mk2
RWB2.9
RWB9
RWB-XP
RWB9
RWB2E
1
102
2
40
200
200cw
252
252cw
270
9
XP
Miniminder
Miniminder E
Sunline
RWB29
RWB270
Select 207
Miniminder
RWB2/6832
RWB200.cw
RWB252.cw
RWB2E.cw
RWB9.cw
This information is based on the backplate supplied with the original programmer.
19
Wiring plans
Smartfit
230V 50Hz
3A RATED
ROOM UNIT
L N E
N
MAINS
Wiring plans
FROST
STAT
A
L
ROOM
UNIT
SL
SL
E
PL
BOILER
POLARITY
FREE
B
PL
N
Y PLAN
S PLAN
BOILER
PUMP
N
HW
VALVE
(S)
CH
VALVE
(S)
ACCESSORY
PORT
3 PORT
VALVE
(Y)
CYLINDER
SENSOR
NEL
PUMP
HW
VALVE
CH
VALVE
CYLINDER
SENSOR
ROOM UNIT
L N E
MAINS
FROST
STAT
A
L
ROOM
UNIT
L
E
BOILER
SL
POLARITY
FREE
B
PL
N
PUMP
NEL
Y PLAN
S PLAN
BOILER
N
L
HW
VALVE
(S)
CH
VALVE
(S)
3 PORT
VALVE
(Y)
ACCESSORY
PORT
CYLINDER
SENSOR
NOT
USED
PUMP
3 - PORT
VALVE
CYLINDER
SENSOR
20
Smartfit
Fault Codes
Fault Code
Description
Action
Blank display
No display
F1
F2
F3
a)
b)
c)
d)
F4
F5
F5
F6
F6
F7
F7
F8
F9
F10
F11
F12
a)
b)
c)
d)
F13
Configuration fault
F14
F15
F16
F17
F18
F19 to F22
F23
F24
Internal fault
*When changing the system selection switch the power must be off.
21
Wiring plans
In the event of a problem, a fault code will be displayed on the Room Unit display. Before removing
Base Unit cover, isolate mains.
Wiring plans
Frost Thermostats
T4360 Frost Thermostat and
L641B Pipe Thermostat
To reduce the risk of frozen pipework during
severe cold weather, Frost Protection can be
installed to protect either the whole central
heating system or the boiler and localised
pipework. These controls are designed to
override the Programmer and Room Thermostat
controls whether wired, wireless or wireless
enabled.
If a Frost Thermostat only is to be installed to protect the whole central heating system, it must be
sited where a rise and fall in heated air temperature can be detected, i.e. in a room with a radiator,
and set to 12-16C. This function is built in to programmable thermostats and Sundial RF.
If the Frost Thermostat is installed outside the heated area, i.e. in a boiler room, garage or attic
space, it is strongly recommended that a Pipe Thermostat be used as well to ensure that
overheating of the property does not occur. The Frost Thermostat should be set to 5C. The Pipe
Thermostat will sense a rise in water temperature in the pipework and then switch the system off. It
should be sited on the boiler return, set at 25C and wired as below.
Mains Voltage Frost Kit: K42008628-001
T4360 Frost Thermostat and L641B Low-Limit
Pipe Thermostat
(Recommend 1mm 2 240Vac rated cable)
T4360A1009
FROST
THERMOSTAT
L641B1004
PIPE
THERMOSTAT
WHITE
V4043H
28MM
BROWN
V4043H
WHITE
V4073A
LIVE TO
BOILER
& PUMP
NOT USED
1
PERMANENT
LIVE
C PLAN /
C PLAN PLUS
S PLAN /
S PLAN PLUS
Y PLAN
3
1
W PLAN
BOILER
T8360B FROST
THERMOSTAT
FROST
PROTECTION
1
ROOM
UNIT
W4672A1009
SMARTFIT BASE UNIT
T8675A PIPE
THERMOSTAT
3
C
TO ROOM
UNIT
When a Frost Thermostat is installed on a central heating system, the fused spur should only be
switched off for servicing and maintenance. If the heating system is to be switched off for any other
reason, eg. holiday, then switching must only be carried out at the Programmer or Timeswitch,
otherwise the Frost Protection is disabled.
22
Wiring Centre
IN
L1
L6
CYL STAT
PROGRAMMER
BOILER
PUMP
L2
HW
ROOM STAT
OFF ON ON E
L S/L N E P/L
E N
GRN/YEL
CH
BROWN
GREY
BLUE
ORANGE
WHITE
L3
LINKS
L4
L5
BROWN
BLUE
MAINS
GRN/YEL
ORANGE
2 AMP
HTG VALVE
GREY
N
E
COMPONENTS LAYOUT
If using Programmer (not basic Time Clock) Cut link 1.
FOR FULLY PUMPED SYSTEMS
FOR S PLAN (two zone valves) Cut links L2 and L4.
If boiler requires pump overrun Cut link L3 also.
If using a 28mm or 1" BSP V4043H the WHITE wire must be isolated
and made safe. Do not connect to a terminal.
FOR Y PLAN (mid position valve) Cut links L4 and L5.
If boiler requires pump overrun Cut link L6 also.
FOR GRAVITY PRIMARY SYSTEMS
FOR C PLAN (one 28mm zone valve) Cut links L2 and L3.
If Room Thermostat is not being used, link terminals 1 and 3
at the ROOM STAT connector block.
BOILER CONNECTIONS
Pump Overrun Boilers
Permanent Live
Switch Live
Neutral
Earth
Pump Live
Wiring Centre
Basic Boilers
Switch Live
Neutral
Earth
S/L
N
E
P/L
23
Wiring plans
A simple alternative to using this guide and a conventional junction box, is the Honeywell Sundial
Plans Wiring Centre (Part number 42005748-001). This provides a clearly marked terminal block for
each component in the system with each wire having its own terminal.
Fault finding
Cylinder Stat
First of all, make sure you have wired to the
correct terminals.
Terminal C (common) is the Left Hand
terminal.
Terminal 1 is the Middle terminal.
Terminal 2 is the Right Hand terminal.
Room Stat
1) Remove wire from Terminal 3.
2) Live to Terminal 1.
3) Turn stat to call, if no live on 3 then faulty.
Suspect the room stat is faulty only if Terminal
3 is not live when calling for heat. (Make sure
Terminal 1 is live). While checking, disconnect
wiring from Terminal 3 to prevent false readings
due to backfeed.
Mid-Position Valve
Suspect the V4073A valve is faulty only if the
valve does not operate as specified in the
following checks (these should be done in
order 1, 2, 3, 4, 5 and 6).
Programmer
Suspect the programmer only:
(a) After you have made sure that any links
required are in place,
(b) After you have made sure that the
Programmer has power to the correct
terminal,
(c) After you have made sure that the
Programmer timing is set up correctly (see
individual Programmer User Guide as
appropriate),
(d) If live does not appear at Heating ON
Terminal when Heating only is selected on
continuous or timed,
(e) If live does not appear at Hot Water ON
Terminal when Hot Water only is selected
on continuous or timed,
(f) If live does not appear on Hot Water OFF
terminal with Hot Water OFF on
programmer.
24
Programmer
Live on both
CH ON &
HW OFF Terminals.
Live on
HW ON
Terminal.
Live on both
CH ON
& HW ON
Terminals.
T6360B Room
Thermostat
No live on any
terminal. (See note 2
for Terminal 3).
L641A Cylinder
Thermostat
Nominal 90 volts.
Live on Terminals
1 & 2 (Note Terminal
1 only becomes 240
volt live after V4073A
valve opens and
Boiler fires). (See
notes below).
V4073A 3 Port
Mid-Position
Valve
Live on White
wire and
Orange wire.
(See note 2
for Grey wire).
Valve in mid
position for CH
and DHW.
NOTES
25
Fault finding
Programmer
Switch Position
Fault finding
Cylinder Stat
First of all, make sure you have wired to the
correct terminals.
Terminal C (common) is the Left Hand
terminal.
Terminal 1 is the Middle terminal.
Terminal 2 is the Right Hand terminal.
26
Programmer
Live on
CH ON
Terminal.
Live on
HW ON
Terminal.
Live on both
HW ON
& CH ON
Terminals.
T6360B Room
Thermostat
No live on any
terminal.
L641A Cylinder
Thermostat
No live on any
terminal.
V4043H
Heating Zone
Valve
Live on Brown,
Grey and Orange
wires.
Live on Brown,
Grey and Orange
wires.
V4043H
Hot Water
Zone Valve
Live on Grey
and Orange
wires.
Live on Brown,
Grey and Orange
wires.
Live on Brown,
Grey and Orange
wires.
NOTES
27
Fault finding
Programmer
Switch Position
Fault finding
The table opposite gives guidance on a quick electrical check for installed wired Sundial C Plans to
help in commissioning and to pin-point the source of any electrical problems.
Remember the Golden Rule when you have a problem. First of all check your wiring. Only start
suspecting faulty components after you are satisfied all wiring is correct.
The following notes will help to identify faulty components.
Cylinder Stat
First of all, make sure you have wired to the
correct terminals.
Terminal C (common) is the Left Hand
terminal.
Terminal 1 is the Middle terminal.
Terminal 2 is the Right Hand terminal.
Suspect the cylinder thermostat is faulty only if
Terminal C is not live when calling for Hot
Water.
Room Stat
1) Remove wire from Terminal 3.
2) Live to Terminal 1.
3) Turn stat to call, if no live on 3 then faulty.
Suspect the room stat is faulty only if Terminal
3 is not live when calling for Heat. (Make sure
Terminal 1 is live). While checking, disconnect
wiring from Terminal 3 to prevent false readings
due to backfeed.
Zone Valve
Suspect the valve is faulty only:
1. If the motor fails to rotate with live applied
to the Brown wire and neutral to the Blue
wire. (Motor can be viewed with valve
cover removed).
Note that the motor stops automatically
when the valve is fully open and stays in
this condition as long as live is applied to
the Brown wire.
2. If the boiler continues to run when the
cylinder stat and/or room stat is satisfied
and/or the clock is in OFF position.
3. (a) SWITCH OFF mains supply.
(b) Disconnect Brown wire to valve, and
terminate safely.
(c) Disconnect White wire and re-connect
to permanent live terminal at junction
box.
(d) Disconnect pump live connection at
junction box and re-connect to
permanent live terminal.
(e) SWITCH ON mains supply.
(f) Valve should remain closed, Orange
wire should become live to fire boiler.
28
Programmer
Live on
CH ON
Terminal.
Live on
HW ON
Terminal.
Live on both
HW ON
& CH ON
Terminals.
T6360B Room
Thermostat
No live on any
terminal.
L641A Cylinder
Thermostat
No live on any
Terminal.
V4043H
Hot Water
Zone Valve
Live on Brown,
Grey and Orange
wires.
Live on Brown,
White, Grey and
Orange wires.
NOTES
29
Fault finding
Programmer
Switch Position
Fault finding
Cylinder Stat
First of all, make sure you have wired to the
correct terminals.
Terminal C (common) is the Left Hand
terminal.
Terminal 1 is the Middle terminal.
Terminal 2 is the Right Hand terminal.
Room Stat
1) Remove wire from Terminal 3.
2) Live to Terminal 1.
3) Turn stat to call, if no live on 3 then faulty.
Programmer
Suspect the programmer only:
(a) After you have made sure that any links
required are in place.
(b) After you have made sure that the
Programmer has power to the correct
terminal.
(c) After you have made sure that the
Programmer timing is set up correctly (see
individual Programmer User Guide as
appropriate).
(d) If live does not appear at Heating ON
Terminal when Heating is selected on
continuous or timed.
(e) If live does not appear at Hot Water ON
Terminal when Hot Water only is selected
on continuous or timed.
30
Programmer
Live on HW ON
Terminal.
Live on both CH ON
and HW ON Terminals.
T6360B Room
Thermostat
No live on Terminals 1 or 3.
L641A Cylinder
Thermostat
V4044C
Diverter Valve
NOTES
1.
2.
3.
4.
5.
31
Fault finding
Programmer
Switch Position
Energy Saving
On/Off Control
On/Off control is the method of control used by
most heating systems in the UK. The controls
simply switch the current supplied to the boiler
on or off at different times.
OpenTherm
OpenTherm provides more precise control on
the boiler than TPI through the control of the
gas valve. It allows the amount of heat
provided by the boiler to be controlled to
match the varying demand signal. By reducing
the flow temperature to a minimum as it leaves
the boiler, the return temperature is kept below
the dew point (55C) whenever possible, thus
allowing the boiler to operate in condensing
mode.
Temperature
Temperature
TPI Control
Time Proportional and Integral (TPI) control is a
method of calculating the demand from a room
thermostat, controlling the boiler so that it fires
for shorter periods as the temperature
approaches the set point. This can offer
savings of up to 10% of energy consumption
(in a single cycle steady state test).
Time
Optimisation
Optimistation is a series of optional features
that save energy while making the user as
comfortable as possible. It does not apply to
hot water, only heating.
Optimum Start
To save energy, let the controls work out when
to come on to suit when you want to be warm.
Every day the boiler will start at the latest
possible moment depending on the weather.
Temperature
Product selection
Time
Time
32
Energy Saving
Delayed Start
Once you have programmed your earliest start
time, the controls will delay the boiler firing time
on warmer days, when it is possible to save
energy.
Optimum Stop
Saves energy and money by switching off
before the normal programme time whenever
possible.
Energy saving with room thermostats
Turning a room thermostat down by 1C can
reduce heating bills by 10% (Government
statistic on www.energysavingtrust.org.uk). In
general the average human body is insensitive
to a band of temperature of 3C. Therefore
your customer wont feel the difference in
temperature, but will notice a difference in their
pocket.
CM927 Wireless
programmable room
thermostat
Product selection
T6360
TPI
Wired
Y6630D
DT90E
DT92E
CM907
CM927
4
4
4
4
Wireless
4
4
Wireless 2 way
Optimum start
1 day / 7 day
10 - 30
10 - 30
5 - 35
5 - 35
5 - 35
5 - 35
33
Product Selection
On the following pages are highlights of the Honeywell products available, for the full list see
www.honeywelluk.com
ST9000 Programmers and Timeswitches
Classic Programmers
ST9100A1008
ST9100C1006
ST9400A1002
ST9400C1000
ST9100S1007
ST9400S1001
ST9500C1015
1 day Timeswitch
7 day Timeswitch
1 day Full programmer
7 day Full programmer
1 day Service timeswitch
1 day Service programmer
7 day Two zone programmer
Motorised Valves
Product selection
Y9120H1009 Pack 1
(wireless enabled timeswitch and wireless room
thermostat)
Cylinder Thermostat
Y9420H1008 Pack 2
(wireless enabled programmer and wireless
room thermostat)
Y9420S1005 Pack 3
(wireless enabled programmer, wireless room
thermostat and cylinder thermostat)
Product Selection
Classic Room Thermostat
T6360B1028
T6360B1069
T6360B1036
T6360B1085
T4360B1015
Y6630D1007
Wireless room thermostat
Room thermostat
Tamperproof room thermostat
Room thermostat with indicator
Room thermostat with 1-5 dial
Room thermostat 16A rated
DT92E1000
Wireless digital room thermostat
CMT901A1044
CM901 1 day Programmable thermostat
CMT907A1041
CM907 7 day Programmable thermostat
Smartfit
CMT921A1042
CM921 1 day Wireless programmable
thermostat
CMT927A1049
CM927 7 day Wireless programmable
thermostat
Y4610A1002
Y4610A1010
Y4610A1028
Y4610A1036
35
Y plan 1 day
Y plan 7 day
S plan 1 day
S plan 7 day
Product selection
DT90E1012
Wired digital room thermostat
Product Selection
Wireless Zoning System
Radiator Thermostats
YZ667A1060
CM Zone Wireless zoning system contains six
wireless thermostatic radiator valves, one
wireless programmable room thermostat and
one receiver.
Product selection
Underfloor heating
36
Product Selection
Automatic Air vent
Filling Valves
37
Product selection
Website
www.honeywelluk.com
More information
38
Training
Installer Training courses
Expand your knowledge of heating and water controls with expert training on our one day Installer
courses, all for 30.
Hands on wiring
Fault finding
Learn about the latest products
Energy conservation
Part L Building Regulations
39
Wireless controls
Zoning
Smartfit
Sundial plans
Frost protection
Control selection
More information
Notes
40